WorldWideScience

Sample records for penetration depth study

  1. Study of the disorder by means of the superconducting penetration depth

    International Nuclear Information System (INIS)

    Arce, R.D.

    1982-11-01

    Measurements of the weak magnetic field penetration depth in the amorphous superconducting systems Lasub(1-x) Msub(x), being M = Cu, Al, Ga and Au, and in the Zr 70 Cu 30 system are presented. Measurements of the sample geometrical factors and the flux expulsion between the lowest temperature reached and the critical temperature, allows the determination of zero temperature penetration depth. The measurement of the flux expulsion as a function of temperature is used to determine the temperature dependence of penetration depth, used to evaluate the temperature dependence superconducting gap. The magnetization measurements have been made using an rf-SQUID. The evolution of the penetration depth with annealing is studied in the La 70 Cu 30 and Zr 70 Cu 30 systems. Measurements of the electrical resistivity and the critical temperature are used to verify the Gorkov equations in these materials. The variation of the penetration depth with annealing suggests that a metallurgical phase separation occurs within the submicrometer range. Penetration depth measurement is a tool to detect this type of phase separation in high kappa materials. (M.E.L.) [es

  2. The Tubular Penetration Depth and Adaption of Four Sealers: A Scanning Electron Microscopic Study

    Directory of Open Access Journals (Sweden)

    Huan Chen

    2017-01-01

    Full Text Available Background. The tubular penetration and adaptation of the sealer are important factors for successful root canal filling. The aim of this study was to evaluate the tubular penetration depth of four different sealers in the coronal, middle, and apical third of root canals as well as the adaptation of these sealers to root canal walls. Materials and Methods. 50 single-rooted teeth were prepared in this study. Forty-eight of them were filled with different sealers (Cortisomol, iRoot SP, AH-Plus, and RealSeal SE and respective core filling materials. Then the specimens were sectioned and scanning electron microscopy was employed to assess the tubular penetration and adaptation of the sealers. Results. Our results demonstrated that the maximum penetration was exhibited by RealSeal SE, followed by AH-Plus, iRoot SP, and Cortisomol. As regards the adaptation property to root canal walls, AH-Plus has best adaptation capacity followed by iRoot SP, RealSeal SE, and Cortisomol. Conclusion. The tubular penetration and adaptation vary with the different sealers investigated. RealSeal SE showed the most optimal tubular penetration, whereas AH-Plus presented the best adaptation to the root canal walls.

  3. Study of temperature increase and optic depth penetration in photo irradiated human tissues

    International Nuclear Information System (INIS)

    Stolik, Suren; Delgado, Jose A.; Perez, Arllene M.; Anasagasti, Lorenzo

    2009-01-01

    Optical radiation is widely applied in the treatment and diagnosis of different pathologies. If the power density of the incident light is sufficiently high to induce a significant temperature rise in the irradiated tissue, then it is also needed the knowledge of the thermal properties of the tissue for a complete understanding of the therapeutic effects. The thermal penetration depth of several human tissues has been measured applying the diffusion approximation of the radiative transfer equation for the distribution of optical radiation. The method, the experimental setup and the results are presented and discussed. (Author)

  4. Photon penetration depth in human brain for light stimulation and treatment: A realistic Monte Carlo simulation study

    Directory of Open Access Journals (Sweden)

    Ting Li

    2017-09-01

    Full Text Available Light has been clinically utilized as a stimulation in medical treatment, such as Low-level laser therapy and photodynamic therapy, which has been more and more widely accepted in public. The penetration depth of the treatment light is important for precision treatment and safety control. The issue of light penetration has been highlighted in biomedical optics field for decades. However, quantitative research is sparse and even there are conflicts of view on the capability of near-infrared light penetration into brain tissue. This study attempts to quantitatively revisit this issue by innovative high-realistic 3D Monte Carlo modeling of stimulated light penetration within high-precision Visible Chinese human head. The properties of light, such as its wavelength, illumination profile and size are concern in this study. We made straightforward and quantitative comparisons among the effects by the light properties (i.e., wavelengths: 660, 810 and 980nm; beam types: Gaussian and flat beam; beam diameters: 0, 2, 4 and 6cm which are in the range of light treatment. The findings include about 3% of light dosage within brain tissue; the combination of Gaussian beam and 810nm light make the maximum light penetration (>5cm, which allows light to cross through gray matter into white mater. This study offered us, the first time as we know, quantitative guide for light stimulation parameter optimization in medical treatment.

  5. Investigating skin penetration depth and shape following needle-free injection at different pressures: A cadaveric study.

    Science.gov (United States)

    Seok, Joon; Oh, Chang Taek; Kwon, Hyun Jung; Kwon, Tae Rin; Choi, Eun Ja; Choi, Sun Young; Mun, Seog Kyun; Han, Seung-Ho; Kim, Beom Joon; Kim, Myeung Nam

    2016-08-01

    The effectiveness of needle-free injection devices in neocollagenesis for treating extended skin planes is an area of active research. It is anticipated that needle-free injection systems will not only be used to inject vaccines or insulin, but will also greatly aid skin rejuvenation when used to inject aesthetic materials such as hyaluronic acid, botulinum toxin, and placental extracts. There has not been any specific research to date examining how materials penetrate the skin when a needle-free injection device is used. In this study, we investigated how material infiltrates the skin when it is injected into a cadaver using a needle-free device. Using a needle-free injector (INNOJECTOR™; Amore Pacific, Seoul, Korea), 0.2 ml of 5% methylene blue (MB) or latex was injected into cheeks of human cadavers. The device has a nozzle diameter of 100 µm and produces a jet with velocity of 180 m/s. This jet penetrates the skin and delivers medicine intradermally via liquid propelled by compressed gasses. Materials were injected at pressures of 6 or 8.5 bars, and the injection areas were excised after the procedure. The excised areas were observed visually and with a phototrichogram to investigate the size, infiltration depth, and shape of the hole created on the skin. A small part of the area that was excised was magnified and stained with H&E (×40) for histological examination. We characterized the shape, size, and depth of skin infiltration following injection of 5% MB or latex into cadaver cheeks using a needle-free injection device at various pressure settings. Under visual inspection, the injection at 6 bars created semi-circle-shaped hole that penetrated half the depth of the excised tissue, while injection at 8.5 bars created a cylinder-shaped hole that spanned the entire depth of the excised tissue. More specific measurements were collected using phototrichogram imaging. The shape of the injection entry point was consistently spherical regardless of the

  6. The penetrating depth analysis of Lunar Penetrating Radar onboard Chang’e-3 rover

    Science.gov (United States)

    Xing, Shu-Guo; Su, Yan; Feng, Jian-Qing; Dai, Shun; Xiao, Yuan; Ding, Chun-Yu; Li, Chun-Lai

    2017-04-01

    Lunar Penetrating Radar (LPR) has successfully been used to acquire a large amount of scientific data during its in-situ detection. The analysis of penetrating depth can help to determine whether the target is within the effective detection range and contribute to distinguishing useful echoes from noise. First, this study introduces two traditional methods, both based on a radar transmission equation, to calculate the penetrating depth. The only difference between the two methods is that the first method adopts system calibration parameters given in the calibration report and the second one uses high-voltage-off radar data. However, some prior knowledge and assumptions are needed in the radar equation and the accuracy of assumptions will directly influence the final results. Therefore, a new method termed the Correlation Coefficient Method (CCM) is provided in this study, which is only based on radar data without any a priori assumptions. The CCM can obtain the penetrating depth according to the different correlation between reflected echoes and noise. To be exact, there is a strong correlation in the useful reflected echoes and a random correlation in the noise between adjacent data traces. In addition, this method can acquire a variable penetrating depth along the profile of the rover, but only one single depth value can be obtained from traditional methods. Through a simulation, the CCM has been verified as an effective method to obtain penetration depth. The comparisons and analysis of the calculation results of these three methods are also implemented in this study. Finally, results show that the ultimate penetrating depth of Channel 1 and the estimated penetrating depth of Channel 2 range from 136.9 m to 165.5 m ({\\varepsilon }r=6.6) and from 13.0 m to 17.5 m ({\\varepsilon }r=2.3), respectively.

  7. Muon-spin rotation (. mu. SR) study of the temperature dependence of the London penetration depth in copper oxide superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Keller, H.; Kuendig, W.; Savic, I.M.; Simmler, H.; Staeuble-Puempin, B.; Warden, M.; Zech, D.; Zimmermann, P. (Physik-Inst., Univ. Zurich (Germany)); Kaldis, E.; Karpinski, J.; Rusiecki, S. (Lab. fuer Festkoerperphysik, ETH Zurich (Switzerland)); Brewer, J.H.; Riseman, T.M.; Schneider, J.W. (TRIUMF and Dept. of Physics, Univ. of British Columbia, Vancouver (Canada)); Maeno, Y.; Rossel, C. (IBM Research Div., Zurich Research Lab., Rueschlikon (Switzerland))

    1991-12-01

    A {mu}SR study of the temperature dependence of the London penetration depth {lambda} in sintered samples of YBa{sub 2}Cu{sub 3}O{sub x} (with various oxygen contents x), YBa{sub 2}Cu{sub 4}O{sub 8} and Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8} is presented. It is found that the temperature behavior of {lambda} of all these cuprate superconductors is consistent with conventional s-wave pairing. However, there are significant differences concerning the exact temperature dependence of {lambda} in these materials. In YBa{sub 2}Cu{sub 3}O{sub x} with high x, the behavior of {lambda}(T) is well described by the two-fluid model (strong coupling), whereas {lambda}(T) in YBa{sub 2}Cu{sub 3}O{sub x} with low x, YBa{sub 2}Cu{sub 4}O{sub 8} and Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8} is in better agreement with weak-coupling BCS theory. Possible reasons for the different temperature behavior of {lambda} in these materials are discussed. (orig.).

  8. Mathematical Based Calculation of Drug Penetration Depth in Solid Tumors

    Directory of Open Access Journals (Sweden)

    Hamidreza Namazi

    2016-01-01

    Full Text Available Cancer is a class of diseases characterized by out-of-control cells’ growth which affect cells and make them damaged. Many treatment options for cancer exist. Chemotherapy as an important treatment option is the use of drugs to treat cancer. The anticancer drug travels to the tumor and then diffuses in it through capillaries. The diffusion of drugs in the solid tumor is limited by penetration depth which is different in case of different drugs and cancers. The computation of this depth is important as it helps physicians to investigate about treatment of infected tissue. Although many efforts have been made on studying and measuring drug penetration depth, less works have been done on computing this length from a mathematical point of view. In this paper, first we propose phase lagging model for diffusion of drug in the tumor. Then, using this model on one side and considering the classic diffusion on the other side, we compute the drug penetration depth in the solid tumor. This computed value of drug penetration depth is corroborated by comparison with the values measured by experiments.

  9. Campbell penetration depth in Fe-based superconductors

    International Nuclear Information System (INIS)

    Prommapan, Plegchart

    2011-01-01

    A 'true' critical current density, j c , as opposite to commonly measured relaxed persistent (Bean) current, j B , was extracted from the Campbell penetration depth, λ c (T,H) measured in single crystals of LiFeAs, and optimally electron-doped Ba(Fe 0.954 Ni 0.046 ) 2 As 2 (FeNi122). In LiFeAs, the effective pinning potential is nonparabolic, which follows from the magnetic field - dependent Labusch parameter α. At the equilibrium (upon field - cooling), α(H) is non-monotonic, but it is monotonic at a finite gradient of the vortex density. This behavior leads to a faster magnetic relaxation at the lower fields and provides a natural dynamic explanation for the fishtail (second peak) effect. We also find the evidence for strong pinning at the lower fields.The inferred field dependence of the pinning potential is consistent with the evolution from strong pinning, through collective pinning, and eventually to a disordered vortex lattice. The value of j c (2 K) ≅ 1.22 x 10 6 A/cm 2 provide an upper estimate of the current carrying capability of LiFeAs. Overall, vortex behavior of almost isotropic, fully-gapped LiFeAs is very similar to highly anisotropic d-wave cuprate superconductors, the similarity that requires further studies in order to understand unconventional superconductivity in cuprates and pnictides. In addition to LiFeAs, we also report the magnetic penetration depth in BaFe 2 As 2 based superconductors including irradiation of FeNi122. In unirradiated FeNi122, the maximum critical current value is, j c (2K) ≅ 3.3 x 10 6 A/cm 2 . The magnetic-dependent feature was observed near the transition temperature in FeTe 0.53 Se 0.47 and irradiated FeNi122. Because of this feature, further studies are required in order to properly calibrate the Campbell penetration depth. Finally, we detected the crossing between the magnetic penetration depth and London penetration depth in optimally hold-doped Ba 0.6 K 0.4 Fe 2 As 2 (BaK122) and isovalent doped BaFe 2 (As 0

  10. Estimation of penetration depth of fission products in cladding Hull

    International Nuclear Information System (INIS)

    Kim, Hee Moon; Jung, Yang Hong; Yoo, Byong Ok; Choo, Yong Sun; Hong, Kwon Pyo

    2005-01-01

    A disposal and a reprocessing for spent fuel rod with high burnup need de-cladding procedure. Pellet in this rod has been separated from a cladding hull to reduce a radioactivity of hull by chemical and mechanical methods. But fission products and actinides(U,Pu) still remain inside of cladding hull by chemical bonding and fission spike, which is called as 'contamination'. More specific removal of this contamination would have been considered. In this study, the sorts of fission products and penetration depth in hull were observed by EPMA test. To analyze this behavior, SRIM 2000 code was also used as energies of fission products and an oxide thickness of hull

  11. Muon-spin-rotation studies of the temperature dependence of the magnetic penetration depth in the YBa2Cu3Ox family and related compounds

    International Nuclear Information System (INIS)

    Zimmermann, P.; Keller, H.; Lee, S.L.; Savic, I.M.; Warden, M.; Zech, D.; Cubitt, R.; Forgan, E.M.; Kaldis, E.; Karpinski, J.; Krueger, C.

    1995-01-01

    A systematic muon-spin-rotation (μ + SR) study is presented of the temperature dependence of the London penetration depth in sintered powder samples of the YBa 2 Cu 3 O x system and related compounds. The in-plane penetration depth λ ab is estimated from the μ + SR depolarization rate of Bi 2 Sr 2 CaCu 2 O 8+δ , YBa 2 Cu 4 O 8 , and a series of samples of the YBa 2 Cu 3 O x family, respectively. It is found that not only the low-temperature value λ ab (0), but also the temperature behavior λ ab (T) is specific to each compound. The form of λ ab (T) can be well characterized by a simple power law. In particular, the YBa 2 Cu 3 O x family shows a systematic variation of the form of λ ab (T) with the oxygen content x which points to a varying coupling strength, whereas λ ab (0) as a function of x suggests a positive charge transfer into the CuO 2 planes with increasing oxygen doping. Furthermore, our data is consistent with an empirical ansatz which has been proposed in the framework of a Bose-gas picture of high-temperature superconductivity. As a consequence, the pressure and the isotope coefficients can be extracted from the μ + SR depolarization rate and compared to direct measurements of these quantities, showing good agreement. Moreover, in the Bose-gas picture the variation of λ ab (T) in the YBa 2 Cu 3 O x family may be interpreted as a crossover from a dense (high-T c ) to a dilute (low-T c ) system of weakly interacting local pairs

  12. Ballistic Phonon Penetration Depth in Amorphous Silicon Dioxide.

    Science.gov (United States)

    Yang, Lin; Zhang, Qian; Cui, Zhiguang; Gerboth, Matthew; Zhao, Yang; Xu, Terry T; Walker, D Greg; Li, Deyu

    2017-12-13

    Thermal transport in amorphous silicon dioxide (a-SiO 2 ) is traditionally treated as random walks of vibrations owing to its greatly disordered structure, which results in a mean free path (MFP) approximately the same as the interatomic distance. However, this picture has been debated constantly and in view of the ubiquitous existence of thin a-SiO 2 layers in nanoelectronic devices, it is imperative to better understand this issue for precise thermal management of electronic devices. Different from the commonly used cross-plane measurement approaches, here we report on a study that explores the in-plane thermal conductivity of double silicon nanoribbons with a layer of a-SiO 2 sandwiched in-between. Through comparing the thermal conductivity of the double ribbon samples with that of corresponding single ribbons, we show that thermal phonons can ballistically penetrate through a-SiO 2 of up to 5 nm thick even at room temperature. Comprehensive examination of double ribbon samples with various oxide layer thicknesses and van der Waals bonding strengths allows for extraction of the average ballistic phonon penetration depth in a-SiO 2 . With solid experimental data demonstrating ballistic phonon transport through a-SiO 2 , this work should provide important insight into thermal management of electronic devices.

  13. Spatial sensitivity and penetration depth of three cerebral oxygenation monitors

    Science.gov (United States)

    Gunadi, Sonny; Leung, Terence S.; Elwell, Clare E.; Tachtsidis, Ilias

    2014-01-01

    The spatial sensitivities of NIRO-100, ISS Oximeter and TRS-20 cerebral oxygenation monitors are mapped using the local perturbation method to inform on their penetration depths and susceptibilities to superficial contaminations. The results show that TRS-20 has the deepest mean penetration depth and is less sensitive than the other monitors to a localized absorption change in the superficial layer. However, an integration time of more than five seconds is required by the TRS-20 to achieve an acceptable level of signal-to-noise ratio, which is the poorest amongst the monitors. With the exception of NIRO-100 continuous wave method, the monitors are not significantly responsive to layer-wide absorption change that occurs in the superficial layer. PMID:25401006

  14. Measuring penetration depth of electron beam welds. Final report

    International Nuclear Information System (INIS)

    Hill, J.W.; Collins, M.C.; Mentesana, C.P.; Watterson, C.E.

    1975-07-01

    The feasibility of evaluating electron beam welds using state-of-the-art techniques in the fields of holographic interferometry, micro-resistance measurements, and heat transfer was studied. The holographic study was aimed at evaluating weld defects by monitoring variations in weld strength under mechanical stress. The study, along with successful work at another facility, proved the feasibility of this approach for evaluating welds, but it did not assign any limitations to the technique. The micro-resistance study was aimed at evaluating weld defects by measuring the electrical resistance across the weld junction as a function of distance along the circumference. Experimentation showed this method, although sensitive, is limited by the same factors affecting other conventional nondestructive tests. Nevertheless, it was successful at distinguishing between various depths of penetration. It was also shown to be a sensitive thickness gage for thin-walled parts. The infrared study was aimed at evaluating weld defects by monitoring heat transfer through the weld under transient thermal conditions. Experimentation showed that this theoretically sound technique is not workable with the infrared equipment currently available at Bendix Kansas City. (U.S.)

  15. Penetration depth and nonlocal manipulation of quantum spin hall edge states in chiral honeycomb nanoribbons.

    Science.gov (United States)

    Xu, Yong; Uddin, Salah; Wang, Jun; Wu, Jiansheng; Liu, Jun-Feng

    2017-08-08

    We have studied numerically the penetration depth of quantum spin hall edge states in chiral honeycomb nanoribbons based on the Green's function method. The changing of edge orientation from armchair to zigzag direction decreases the penetration depth drastically. The penetration depth is used to estimate the gap opened for the finite-size effect. Beside this, we also proposed a nonlocal transistor based on the zigzag-like chiral ribbons in which the current is carried at one edge and the manipulation is by the edge magnetization at the other edge. The difficulty that the edge magnetization is unstable in the presence of a ballistic current can be removed by this nonlocal manipulation.

  16. Evaluation of the penetration depth of the shell welds by electrical methods

    International Nuclear Information System (INIS)

    Laille, Alain.

    1979-07-01

    The aim of the present work is the development of two electrical non-destructive methods (eddy currents and potentiometry) to estimate the penetration depth of electron bombardment welds. To illustrate the study and show its potential applications these methods are used on various materials (1 to 3 mm thick) and the results compared with the real welded depth evaluated after sectioning. Finally the potentiometric set-up is coupled to a data acquisition and processing system [fr

  17. Influence of jet thrust on penetrator penetration when studying the structure of space object blanket

    Directory of Open Access Journals (Sweden)

    N. A. Fedorova

    2014-01-01

    Full Text Available The article presents the calculation-and-theory-based research results to examine the possibility for using the jet thrust impulse to increase a penetration depth of high-velocity penetrator modules. Such devices can be used for studies of Earth surface layer composition, and in the nearest future for other Solar system bodies too. Research equipment (sensors and different instruments is housed inside a metal body of the penetrator with a sharpened nose that decreases drag force in soil. It was assumed, that this penetrator is additionally equipped with the pulse jet engine, which is fired at a certain stage of penetrator motion into target.The penetrator is considered as a rigid body of variable mass, which is subjected to drag force and reactive force applied at the moment the engine fires. A drag force was represented with a binomial empirical law, and penetrator nose part was considered to be conical. The jet thrust force was supposed to be constant during its application time. It was in accordance with assumption that mass flow and flow rate of solid propellant combustion products were constant. The amount of propellant in the penetrator was characterized by Tsiolkovsky number Z, which specifies the ratio between the fuel mass and the penetrator structure mass with no fuel.The system of equations to describe the penetrator dynamics was given in dimensionless form using the values aligned with penetration of an equivalent inert penetrator as the time and penetration depth scales. Penetration dynamics of penetrator represented in this form allowed to eliminate the influence of penetrator initial mass and its cross-section diameter on the solution results. The lack of such dependency is convenient for comparing the calculation results since they hold for penetrators of various initial masses and cross-sections.To calculate the penetration a lunar regolith was taken as a soil material. Calculations were carried out for initial velocities of

  18. Wavelength-dependent penetration depth of near infrared radiation into cartilage.

    Science.gov (United States)

    Padalkar, M V; Pleshko, N

    2015-04-07

    Articular cartilage is a hyaline cartilage that lines the subchondral bone in the diarthrodial joints. Near infrared (NIR) spectroscopy is emerging as a nondestructive modality for the evaluation of cartilage pathology; however, studies regarding the depth of penetration of NIR radiation into cartilage are lacking. The average thickness of human cartilage is about 1-3 mm, and it becomes even thinner as OA progresses. To ensure that spectral data collected is restricted to the tissue of interest, i.e. cartilage in this case, and not from the underlying subchondral bone, it is necessary to determine the depth of penetration of NIR radiation in different wavelength (frequency) regions. In the current study, we establish how the depth of penetration varies throughout the NIR frequency range (4000-10 000 cm(-1)). NIR spectra were collected from cartilage samples of different thicknesses (0.5 mm to 5 mm) with and without polystyrene placed underneath. A separate NIR spectrum of polystyrene was collected as a reference. It was found that the depth of penetration varied from ∼1 mm to 2 mm in the 4000-5100 cm(-1) range, ∼3 mm in the 5100-7000 cm(-1) range, and ∼5 mm in the 7000-9000 cm(-1) frequency range. These findings suggest that the best NIR region to evaluate cartilage with no subchondral bone contribution is in the range of 4000-7000 cm(-1).

  19. Study on Penetration Characteristics of Tungsten Cylindrical Penetrator

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Jong Hyun; Lee, Young Shin; Kim, Jae Hoon [Chungnam Nat' l Univ., Daejeon (Korea, Republic of); Bae, Yong Woon [Agency for Defense Development, Daejeon (Korea, Republic of)

    2013-09-15

    The design of missile require extremely small warheads that must be highly efficient and lethal. The penetration characteristics of each penetrator and the total number of penetrators on the warhead are obvious key factors that influence warhead lethality. The design of the penetrator shape and size are directly related to the space and weight of the warhead. The design of the penetrator L/D was directly related to the space and weight of the warhead. L and D are the length and the diameter of the projectile, respectively. The AUTODYN-3a code was used to study the effect of penetrator penetration. The objective of numerical analysis was to determine the penetration characteristics of penetrator produced by hypervelocity impacts under different initial conditions such as initial velocity, obliquity angle and L/D of penetrator. The residual velocity and residual mass were decreased with increasing initial impact velocity under L/D{<=}4.

  20. The penetration depth and lateral distribution of pigment related to the pigment grain size and the calendering of paper

    International Nuclear Information System (INIS)

    Buelow, K.; Kristiansson, P.; Schueler, B.; Tullander, E.; Oestling, S.; Elfman, M.; Malmqvist, K.; Pallon, J.; Shariff, A.

    2002-01-01

    The interaction of ink and newspaper has been investigated and the specific question of penetration of ink into the paper has been addressed with a nuclear microprobe using particle induced X-ray emission. The penetration depth of the newsprint is a critical factor in terms of increasing the quality of newsprint and minimising the amount of ink used. The objective of the experiment was to relate the penetration depth of pigment with the calendering of the paper. The dependence of the penetration depth on the pigment grain size was also studied. To study the penetration depth of pigment in paper, cyan ink with Cu as a tracer of the coloured pigment was used. For the study of the penetration depth dependence of pigment size, specially grounded Japanese ink with well-defined pigment grain size was used. This was compared to Swedish ink with pigment grains with normal size-distribution. The results show that the calendering of the paper considerably affects the penetration depth of ink

  1. Lidar Penetration Depth Observations for Constraining Cloud Longwave Feedbacks

    Science.gov (United States)

    Vaillant de Guelis, T.; Chepfer, H.; Noel, V.; Guzman, R.; Winker, D. M.; Kay, J. E.; Bonazzola, M.

    2017-12-01

    Satellite-borne active remote sensing Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations [CALIPSO; Winker et al., 2010] and CloudSat [Stephens et al., 2002] provide direct measurements of the cloud vertical distribution, with a very high vertical resolution. The penetration depth of the laser of the lidar Z_Opaque is directly linked to the LongWave (LW) Cloud Radiative Effect (CRE) at Top Of Atmosphere (TOA) [Vaillant de Guélis et al., in review]. In addition, this measurement is extremely stable in time making it an excellent observational candidate to verify and constrain the cloud LW feedback mechanism [Chepfer et al., 2014]. In this work, we present a method to decompose the variations of the LW CRE at TOA using cloud properties observed by lidar [GOCCP v3.0; Guzman et al., 2017]. We decompose these variations into contributions due to changes in five cloud properties: opaque cloud cover, opaque cloud altitude, thin cloud cover, thin cloud altitude, and thin cloud emissivity [Vaillant de Guélis et al., in review]. We apply this method, in the real world, to the CRE variations of CALIPSO 2008-2015 record, and, in climate model, to LMDZ6 and CESM simulations of the CRE variations of 2008-2015 period and of the CRE difference between a warm climate and the current climate. In climate model simulations, the same cloud properties as those observed by CALIOP are extracted from the CFMIP Observation Simulator Package (COSP) [Bodas-Salcedo et al., 2011] lidar simulator [Chepfer et al., 2008], which mimics the observations that would be performed by the lidar on board CALIPSO satellite. This method, when applied on multi-model simulations of current and future climate, could reveal the altitude of cloud opacity level observed by lidar as a strong constrain for cloud LW feedback, since the altitude feedback mechanism is physically explainable and the altitude of cloud opacity accurately observed by lidar.

  2. Study of Penetration Technology

    Science.gov (United States)

    1976-11-01

    srecimens fabricated at the AFATL, AISI-01 oil quenched bar stock was used. Three of the projectiles used in the Eglin penetration experiments are shown...in the Mathema- tical Laboratory at Eglin AFB, is essencially a fourth order Runge-Kutta numerical method for solving simultaneous differential...C9G. VEL. X-COMPo (M4/5): d!10. I oil 140. 107. 82. RmCC~kr’ED TIME OF MAXIftjM/MINIM94U COIL VOLTAGE tSI MAX 0040 A 55 *.03J04A 0 0 05ji6 .000634 MIN

  3. Radio frequency absorption and penetration depth limits in whole body MR imaging

    International Nuclear Information System (INIS)

    Roschmann, P.

    1986-01-01

    There is a continual debate over the ultimate limits to MR imaging at higher field strengths owing to the problems of increasing radio frequency (RF) power deposition and decreasing depth of B/sub 1/ field penetration in the patient. The authors present experimental results of RF absorption and penetration studies in humans for frequencies (f) of 30 to 220 MHz. Results were mostly derived from RF measurements of the effects of loading different types of head, body, and surface coils during imaging of volunteers and metal phantoms. Imaging at 2 T (85 MHz) does not exhibit significant RF problems; the local SAR amounts to 0.06 W/kg for a π-pulse of 1 msec and a TR of 1 sec. RF measurements of coil loading yield SAR -- f/sup 2.2/. The derived effective penetration depth drops from 17 cm at 85 MHz to 7 cm at 220 MHz. Head imaging appears possible up to 220 MHz (5 T). Body and surface coil imaging is subjected to increasing limitations in size or depth above 100 MHz

  4. Influence of the impurities on the depth of penetration with carbon steel weldings

    Directory of Open Access Journals (Sweden)

    O. Savytsky

    2014-04-01

    Full Text Available In this paper the results of the research about the influence of the impurities on the depth of penetration with carbon steels weldings of different chemical composition are presented. These data suggest that presence of those impurities, such as sulphure and oxygen, in the steel, increases the depth of penetration to 1,3 - 1,5 times compared to welding refined steels. Applying activating fluxes for welding high tensile steels, provides an increase in the depth of penetration of 2 - 3 times.

  5. Impact of different solar penetration depths on climate simulations

    Directory of Open Access Journals (Sweden)

    Xiaobing Zhou

    2015-01-01

    Full Text Available Three different estimates of shortwave attenuation depth (SWAD of photosynthetically active radiation (PAR derived from remotely sensed ocean colour data have been tested in an ocean general circulation model (OGCM forced with interannual atmospheric forcings. Two estimates (referred to as [Kd(PAR]1-1 and [Kd(PAR]2-1 are calculated from different algorithms based on the diffusive attenuation coefficient at 490 nm and the third one ([Kd(AVE]1-1 is just an average of [Kd(PAR]1-1 and [Kd(PAR]2-1. [Kd(PAR]2-1 is larger than [Kd(PAR]1-1 almost everywhere in the tropical oceans. Our results show that the OGCM with [Kd(PAR]2-1 produces warmer sea surface temperature (SST in the eastern equatorial Pacific and Atlantic and leads to reduce a cold bias in the equatorial cold tongue regions. It has warmer subsurface temperatures in the low latitude, a slower meridional velocity and Pacific equatorial undercurrent (EUC than the model with [Kd(PAR]1-1. These results are similar to previous studies, although we use a different model and different methods. This study has further analysis and firstly reveals that slower EUC and meridional velocity in the model with [Kd(PAR]2-1 are mainly related to the changes of the acceleration due to zonal density gradient. This acceleration driving the EUC eastward in the subsurface becomes smaller in the subsurface along the equatorial Pacific. However, near the sea surface, the zonally averaged accelerations over the different ocean basins are larger in the model with [Kd(PAR]2-1 than that with [Kd(PAR]1-1, which pushes back the poleward meridional transport. The interannual variability in the model with [Kd(PAR]2-1 is generally weaker than that in the experiment with [Kd(PAR]1-1 due to a deeper mixed layer depth. The vertical temperature errors averaged horizontally within the domain of 30°S to 30°N in the experiment with [Kd(AVE]1-1 are almost in the middle of errors of the other two experiments. This indicates that

  6. Closed Loop Control of Penetration Depth during CO2 Laser Lap Welding Processes

    Directory of Open Access Journals (Sweden)

    Antonio Ancona

    2012-08-01

    Full Text Available In this paper we describe a novel spectroscopic closed loop control system capable of stabilizing the penetration depth during laser welding processes by controlling the laser power. Our novel approach is to analyze the optical emission from the laser generated plasma plume above the keyhole, to calculate its electron temperature as a process-monitoring signal. Laser power has been controlled by using a quantitative relationship between the penetration depth and the plasma electron temperature. The sensor is able to correlate in real time the difference between the measured electron temperature and its reference value for the requested penetration depth. Accordingly the closed loop system adjusts the power, thus maintaining the penetration depth.

  7. Spherical and cylindrical cavity expansion models based prediction of penetration depths of concrete targets.

    Directory of Open Access Journals (Sweden)

    Xiaochao Jin

    Full Text Available The cavity expansion theory is most widely used to predict the depth of penetration of concrete targets. The main purpose of this work is to clarify the differences between the spherical and cylindrical cavity expansion models and their scope of application in predicting the penetration depths of concrete targets. The factors that influence the dynamic cavity expansion process of concrete materials were first examined. Based on numerical results, the relationship between expansion pressure and velocity was established. Then the parameters in the Forrestal's formula were fitted to have a convenient and effective prediction of the penetration depth. Results showed that both the spherical and cylindrical cavity expansion models can accurately predict the depth of penetration when the initial velocity is lower than 800 m/s. However, the prediction accuracy decreases with the increasing of the initial velocity and diameters of the projectiles. Based on our results, it can be concluded that when the initial velocity is higher than the critical velocity, the cylindrical cavity expansion model performs better than the spherical cavity expansion model in predicting the penetration depth, while when the initial velocity is lower than the critical velocity the conclusion is quite the contrary. This work provides a basic principle for selecting the spherical or cylindrical cavity expansion model to predict the penetration depth of concrete targets.

  8. Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Woods, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Winkler, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-01-01

    This study examines the effective moisture penetration depth (EMPD) model, and its suitability for building simulations. The EMPD model is a compromise between the simple, inaccurate effective capacitance approach and the complex, yet accurate, finite-difference approach. Two formulations of the EMPD model were examined, including the model used in the EnergyPlus building simulation software. An error in the EMPD model we uncovered was fixed with the release of EnergyPlus version 7.2, and the EMPD model in earlier versions of EnergyPlus should not be used.

  9. Effect of tool rotational speed and penetration depth on dissimilar aluminum alloys friction stir spot welds

    Directory of Open Access Journals (Sweden)

    Joaquín M. Piccini

    2017-03-01

    Full Text Available In the last years, the automotive industry is looking for the use of aluminum parts in replace of steel parts in order to reduce the vehicles weight. These parts have to be joined, for instance, by welding processes. The more common welding process in the automotive industry is the Resistance Spot Welding (RSW technique. However, RSW of aluminum alloys has many disadvantages. Regarding this situation, a variant of the Friction Stir Welding process called Friction Stir Spot Welding (FSSW has been developed, showing a strong impact in welding of aluminum alloys and dissimilar materials in thin sheets. Process parameters affect the characteristics of the welded joints. However, the information available on this topic is scarce, particularly for dissimilar joints and thin sheets. The aim of this work was to study the effect of the rotational speed and the tool penetration depth on the characteristics of dissimilar FSS welded joints. Defects free joints have been achieved with higher mechanical properties than the ones reported. The maximum fracture load was 5800 N. It was observed that the effective joint length of the welded spots increased with the tool penetration depth, meanwhile the fracture load increased and then decreased. Finally, welding at 1200 RPM produced welded joints with lower mechanical properties than the ones achieved at 680 and 903 RPM.

  10. Convenient measurement of the residual stress using X-ray penetration depth

    International Nuclear Information System (INIS)

    Ukai, Takayoshi; Shibano, Junichi

    1994-01-01

    The residual stress measured with a characteristic X-ray is usually evaluated as a surface stress. However, it is a weighted mean value over all penetration depth of X-ray. Thus, the classical sin 2 Ψ method with the characteristic X-ray is difficult to use for measuring the steep gradient of residual stress that occurs along the depth direction in a subsurface layer of the material after cold rolling and grinding. This paper presents a convenient method of the residual stress measurement along the depth direction in a subsurface layer using the penetration depth depending on a characteristic X-ray. The residual stress distribution of JIS SKS51 steel plate was measured as an example of applying this method. As a result, it could be confirmed that a residual stress distribution along the depth direction in a subsurface layer could be evaluated nondestructively by this convenient method. (author)

  11. Numerical analysis on effective electric field penetration depth for interdigital impedance sensor

    International Nuclear Information System (INIS)

    Kim, Chon-ung; Jong, Hakchol; Ro, Cholwu; Pak, Gilhung; Im, Songil; Li, Guofeng; Li, Jie; Song, Yunho

    2013-01-01

    Interdigital (finger-like) electrodes are widely used for electrical impedance and capacitance tomography of composite dielectric materials and complex insulating structures. Because of their advantages, they are now effectively introduced as capacitance sensors into a variety of industrial branches, agriculture, medical science, biological engineering, military branches, etc. In order to effectively apply the so-called interdigital impedance sensors in practice, of great importance is to optimize the sensor design parameters such as the electric field penetration depth, signal strength and so on. The general design principles of the interdigital capacitance sensor have been discussed for a long time by many researchers. However, there is no consensus on the definition of the effective electric field penetration depth of interdigital electrode. This paper discusses how to determine the effective electric field penetration depth of interdigital sensor on the basis of the refractive principle of electric field intensity and the FEM analyses of electric field distribution and capacitance for the sensor model.

  12. Temperature dependence of the experimental penetration depth of superconducting thin films

    International Nuclear Information System (INIS)

    Fink, H.J.; Gruenfeld, V.; Pastawski, H.

    1982-01-01

    Experimental magnetic field penetration depths delta(t,d,H) of the stable and superheated Meissner state were calculated as a function of temperature for various applied magnetic fields and various film thicknesses for two cases: (1) lambda(t)/d<< kappa→infinity and (2) kappa< or approx. =2lambda(t)/d (lambda is the Ginzburg-Landau penetration depth, d is the film thickness, kappa is the GL parameter). The results of the first case should be a useful tool for obtaining lambda(0) of amorphous superconducting thin films

  13. Temperature dependence of the optical conductivity and penetration depth in superconductor MgB2 film

    International Nuclear Information System (INIS)

    Moarrefi, M.; Yavari, H.; Elahi, M.

    2010-01-01

    By using Green's function method the temperature dependence of the optical conductivity and penetration depth of high-quality MgB 2 film are calculated in the framework of the two-band model. We compare our results with experimental data and we argue that the single gap model is insufficient to describe the optical and penetration depth behavior, but the two-band model with different symmetries describes the data rather well. In the two gap model we consider that the both components of optical conductivity are a weighted sum of the contribution from σ and π bonds and hybridization between them is negligible.

  14. Determination of the magnetic penetration depth in a superconducting Pb film

    International Nuclear Information System (INIS)

    Brisbois, J.; Silhanek, A. V.; Raes, B.; Van de Vondel, J.; Moshchalkov, V. V.

    2014-01-01

    By means of scanning Hall probe microscopy technique, we accurately map the magnetic field pattern produced by Meissner screening currents in a thin superconducting Pb stripe. The obtained field profile allows us to quantitatively estimate the Pearl length Λ without the need of pre-calibrating the Hall sensor. This fact contrasts with the information acquired through the spatial field dependence of an individual flux quantum where the scanning height and the magnetic penetration depth combine in a single inseparable parameter. The derived London penetration depth λ L coincides with the values previously reported for bulk Pb once the kinetic suppression of the order parameter is properly taken into account

  15. Multiscale analysis of depth-dependent soil penetration resistance in a tropical soil

    Science.gov (United States)

    Paiva De Lima, Renato; Santos, Djail; Medeiros Bezerra, Joel; Machado Siqueira, Glécio; Paz González, Antonio

    2013-04-01

    Soil penetration resistance (PR) is widely used because it is linked to basic soil properties; it is correlated to root growth and plant production and is also used as a practical tool for assessing soil compaction and to evaluate the effects of soil management. This study investigates how results from multifractal analysis can quantify key elements of depth-dependent PR profiles and how this information can be used at the field scale. We analyzed multifractality of 50 PR vertical profiles, measured from 0 to 40 cm depth and randomly located on a 6.5 ha sugar cane field in north-eastern Brazil. According to the Soil Taxonomy, the studied soil was classified as an Orthic Podsol The scaling property of each profile was typified by singularity and Rényi spectra estimated by the method of moments. The Hurst exponent was used to parameterize the autocorrelation of the vertical PR data sets. Singularity and Rènyi spectra showed the vertical PR data sets exhibited a well-defined multifractal structure. Hurst exponent values were close to one indicating strong persistence in PR variation with soil depth. Also Hurst exponent was negatively and significantly correlated to coefficient of variation (CV) and skewness of the depth-dependent PR. Multifractal analysis added valuable information to describe the spatial arrangement of depth-dependent penetrometer data sets, which was not taken into account by classical statistical indices. Multifractal parameters were mapped over the experimental field and compared with mean, maximum and minimum values of PR; these maps showed the multifractal approach also may complete information provided by descriptive statistics at the field scale.

  16. Magnetic penetration depth δ o and critical current density in Y-BA-Cu-O crystals

    International Nuclear Information System (INIS)

    Zavaritsky, N.V.; Zavaritsky, V.N.

    1989-01-01

    Magnetic penetration depthδ o ∼1.03 10 - 5 cm and critical current density (j c = 0.5 divided-by 1 x 10 5 A/cm 2 at T/T ∼0.98) are determined from low-field do magnetization measurements on Y 1 Ba 2 Cu 3 O 7 - crystals

  17. Considerations on Dop (Depth Of Penetration) Test for Evaluation of Ceramics Materials Used in Ballistic Protection

    Science.gov (United States)

    Popa, Ioan-Dan; Dobriţa, Florin

    2017-12-01

    Tremendous amount of funds and other resorces were invested in studying the response of ceramic materials under ballistic impact, the main goal being to find a way to increase the protection of soldiers and the vehicles used in the modern battlespace. Using of ceramic materials especially carbon based (carbides), nitrogen based (nitrides) and oxygen based (oxides) ceramics in order to increase the protection level of ballistic equipment could be, sometimes, a big challenge when trying to use the proper test in order to evaluate and compare their performances. The role of the tests is to provide a better understanding of their response in different situations and, as a consequence, to make them more efficient as armour components through future improvements. The paper presents shortly the main tests which are used and eventually standardised for evaluating the ballistic behaviour of the ceramics and other armour components, with a special focus to DOP (Depth of Penetration) Tests.

  18. Power-law index and penetration depth of (NdxSmxGd1−2x)Ba2Cu3O7−δ films studied by AC susceptibility

    DEFF Research Database (Denmark)

    Li, Xiaofen; He, Dong; Grivel, Jean-Claude

    2012-01-01

    Superconducting (NdxSmxGd1−2x)Ba2Cu3O7−δ films with x=0, 0.1, 0.25, 0.33 were grown by PLD on STO single crystal substrates. The power-law index n and penetration depth λ are studied by AC susceptibility. During cooling, n in films with x ≠ 0 increases much slower compared with the films with x =....... The films with x ≠ 0 also tend to have a longer penetration depth. These properties might be related to the higher possibility for disorder in the mixed (Nd,Sm,Gd)BCO films....

  19. The Beryllium 7 Depth Distribution Study

    International Nuclear Information System (INIS)

    Jalal Sharib; Zainudin Othman; Dainee Nor Fardzila Ahmad Tugi

    2014-01-01

    The aim of this paper is to study the evolution of 7Be depth distribution in a soil profile. The soil samples have been collected by using plastic core in bare area in Bangi, Malaysia. Each of the soil core samples has been sectioned into 2 mm increments to a depth of 4 cm and the samples are subsequently oven dried at 45°C and gently disaggregated. The sample is passed through a < 2 mm sieve and packed into plastic pot for 7Be analysis using gamma spectrometry with a 24 hour count time. From the findings, show the 7Be depth penetration from this study decreases exponentially with depth and is confined within the top few centimeters and similar with other works been reported. The further discussion for this findings will be presented in full paper. (author)

  20. Multiaxial stress analysis taking account of penetration depth of x-rays, 3

    International Nuclear Information System (INIS)

    Yoshioka, Yasuo; Sasaki, Toshihiko; Kuramoto, Makoto.

    1985-01-01

    In the past X-ray stress analysis in which the effect of stress gradients was taken into account within the penetration depth of X-rays, three assumptions have been made; 1) the stress gradient is linear in respect to the depth from the specimen surface, 2) the penetration depth of X-ray is a function of Sin 2 PSI and 3) the strain measured by X-rays corresponds to the weighted average strain on the intensity of the diffracted X-rays. A problem, however, still remains on the assumption of the X-ray penetration depth. We sometimes observed noticiable errors in the stage of the numerical simulation and these errors depend on the combination of stress components in a stress tensor. In the present paper, we proposed a new X-ray multiaxial stress analysis without using the assumption of the X-ray penetration depth. This analysis is also applicable to both the iso-inclination method ( OHM -goniometer) and the side inclination method (PSI-goniometer). The weighted average strain by X-rays, 1 >(phi), is expressed as a 4th degree function of cosPSI for iso-inclination method and 3rd degree for side inclination method. By rearranging this function as a sum of average strain, ( 1 >(0 0 )+ 1 >(90 0 )), and difference of average strain, ( 1 >(0 0 )- 1 >(90 0 )), we can solve the stress components with sufficient accuracy by a least squares method. The validity of this method was proved through numerical simulations and experiments. (author)

  1. Crystal growth vs. conventional acid etching: A comparative evaluation of etch patterns, penetration depths, and bond strengths

    Directory of Open Access Journals (Sweden)

    Devanna Raghu

    2008-01-01

    Full Text Available The present study was undertaken to investigate the effect on enamel surface, penetration depth, and bond strength produced by 37% phosphoric acid and 20% sulfated polyacrylic acid as etching agents for direct bonding. Eighty teeth were used to study the efficacy of the etching agents on the enamel surface, penetration depth, and tensile bond strength. It was determined from the present study that a 30 sec application of 20% sulfated polyacrylic acid produced comparable etching topography with that of 37% phosphoric acid applied for 30 sec. The 37% phosphoric acid dissolves enamel to a greater extent than does the 20% sulfated polyacrylic acid. Instron Universal testing machine was used to evaluate the bond strengths of the two etching agents. Twenty percent sulfated polyacrylic acid provided adequate tensile bond strength. It was ascertained that crystal growth can be an alternative to conventional phosphoric acid etching as it dissolves lesser enamel and provides adequate tensile bond strength.

  2. Penetration tests to study the mechanical tribological properties of chisel type knife

    Science.gov (United States)

    Vlăduţoiu, L.; Chişiu, G.; Andrei, T.; Predescu, A.; Muraru, C.; Vlăduţ, V.

    2017-02-01

    The goal of this study was to analyze the behaviour of chisel knife type penetration in a certain type of sand. A series of penetration tests were carried out with chisel knife type, the answer to penetration depending mainly on nature, shape, size of knife and operating parameters such as speed, depth and working conditions. Tests were conducted in work conditions with wet sand and dry sand and determined force of resistance to penetration of the chisel knife type to a certain depth.

  3. Singularity of the London penetration depth at quantum critical points in superconductors.

    Science.gov (United States)

    Chowdhury, Debanjan; Swingle, Brian; Berg, Erez; Sachdev, Subir

    2013-10-11

    We present a general theory of the singularity in the London penetration depth at symmetry-breaking and topological quantum critical points within a superconducting phase. While the critical exponents and ratios of amplitudes on the two sides of the transition are universal, an overall sign depends upon the interplay between the critical theory and the underlying Fermi surface. We determine these features for critical points to spin density wave and nematic ordering, and for a topological transition between a superconductor with Z2 fractionalization and a conventional superconductor. We note implications for recent measurements of the London penetration depth in BaFe2(As(1-x)P(x))2 [K. Hashimoto et al., Science 336, 1554 (2012)].

  4. Theory of the c-axis penetration depth in the cuprates

    International Nuclear Information System (INIS)

    Radtke, R.J.; Kostur, V.N.; Levin, K.

    1996-01-01

    Recent measurements of the London penetration-depth tensor in the cuprates find a weak temperature dependence along the c direction that is seemingly inconsistent with evidence for d-wave pairing deduced from in-plane measurements. We demonstrate in this paper that these disparate results are not in contradiction, but can be explained within a theory based on incoherent quasiparticle hopping between the CuO 2 layers. By relating the calculated temperature dependence of the penetration depth λ c (T) to the c-axis resistivity, we show how the measured ratio λ 2 c (0)/λ 2 c (T) can provide insight into the behavior of c-axis transport below T c and the related issue of open-quote open-quote confinement.close-quote close-quote copyright 1996 The American Physical Society

  5. Measurement setup for the magnetic penetration depth and superfluid stiffness in thin superconducting films

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Lorenz; Brunner, Markus Christopher Paul; Schneider, Ina; Kronfeldner, Klaus; Strunk, Christoph [Institute for exp. and appl. Physics, University of Regensburg (Germany); Bousquet, Jessica; Bustarret, Etienne [Institut NEEL, Grenoble (France)

    2015-07-01

    A mutual inductance measurement setup has been established in order to determine the magnetic penetration depths of thin film superconductors. By measuring the variation of the mutual inductance M, the temperature dependent penetration depth can be evaluated. The setup has been characterized using thin aluminum and niobium films as a reference. Temperature dependence of λ of B-doped diamond films is determined down to 0.3 K and compared with theoretical expectations. The impact of the doping ratio B/C and film thickness on λ and T{sub c} is investigated. Correlation between the film impedance σ = σ{sub 1} - i σ{sub 2} and λ is examined.

  6. Geometry of X-ray based measurement of residual strain at desired penetration depth

    Energy Technology Data Exchange (ETDEWEB)

    Morawiec, A. [Polish Academy of Sciences, Institute of Metallurgy and Materials Science, Krakow (Poland)

    2017-10-15

    X-ray based measurement of residual lattice strains at chosen penetration depth is one of the methods for investigating strain inhomogeneities in near-surface layers of polycrystalline materials. The measurement relies on determining shifts of Bragg peaks for various directions of the scattering vector with respect to the specimen. At each of these directions, to reach a given the penetration depth, a proper specimen orientation is required. The task of determining such orientations, albeit elementary, is quite intricate. The existing literature describes only partial solutions with unspecified domains of application, which fail if applied to beyond the domains. Therefore, geometric aspects of the measurement are analyzed in details. Explicit bounds on measurement parameters are given. The equation fundamental for the procedure is solved with respect to specimen orientations. For a given direction of the scattering vector, there are generally four different specimen orientations leading to the same penetration depth. This simple fact (overlooked in previous analyses) can be used for improving reliability of measurement results. Analytical formulas for goniometer angles representing these orientations are provided. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  7. Low temperature London penetration depth and superfluid density in Fe-based superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyunsoo [Iowa State Univ., Ames, IA (United States)

    2013-01-01

    The superconducting gap symmetry of the Fe-based superconductors was studied by measurements and analysis of London penetration depth and super uid density. Tunnel diode resonator technique for these measurements was implemented in a dilution refrigerator allowing for the temperatures down to 50 mK. For the analysis of the super uid density, we used both experimental studies of Al-coated samples and original thermodynamic approach based on Rutgers relation. In three systems studied, we found that the superconducting gap at the optimal doping is best described in multi-gap full gap scenario. By performing experiments on samples with arti cially introduced disorder with heavy ion irradiation, we show that evolution of the superconducting transition temperature and of the super uid density are consistent with full-gap sign changing s superconducting state. The superconducting gap develops strong modulation both in the under-doped and the over-doped regimes. In the terminal hole-doped KFe{sub 2}As{sub 2}, both temperature dependence of the super uid density and its evolution with increase of the scattering rate are consistent with symmetry imposed vertical line nodes in the superconducting gap. By comparative studies of hole-doped (Ba,K)Fe{sub 2}As{sub 2} and electron-doped Ca10-3-8, we show that the superconducting gap modulation in the under-doped regime is intrinsic and is not induced by the coexisting static magnetic order.

  8. The oxygen isotope effect on the in-plane penetration depth in cuprate superconductors

    International Nuclear Information System (INIS)

    Khasanov, R; Shengelaya, A; Morenzoni, E; Conder, K; Savic, I M; Keller, H

    2004-01-01

    Muon spin rotation (μSR) studies of the oxygen isotope ( 16 O/ 18 O) effect (OIE) on the in-plane magnetic field penetration depth λ ab in cuprate high-temperature superconductors (HTS) are presented. First, the doping dependence of the OIE on the transition temperature T c in various HTS is briefly discussed. It is observed that different cuprate families show similar doping dependences of the OIE on T c . Then, bulk μSR, low-energy μSR, and magnetization studies of the total and site-selective OIE on λ ab are described in some detail. A substantial OIE on λ ab was observed in various cuprate families at all doping levels, suggesting that cuprate HTS are non-adiabatic superconductors. The experiments clearly demonstrate that the total OIE on T c and λ ab arise from the oxygen sites within the superconducting CuO 2 planes, demonstrating that the phonon modes involving the movement of planar oxygen are dominantly coupled to the supercarriers. Finally, it is shown that the OIE on T c and λ ab exhibit a relation that appears to be generic for different families of cuprate HTS. The observation of these unusual isotope effects implies that lattice effects play an essential role in cuprate HTS and have to be considered in any realistic model of high-temperature superconductivity

  9. The oxygen isotope effect on the in-plane penetration depth in cuprate superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Khasanov, R [Physik-Institut der Universitaet Zuerich, CH-8057 Zurich (Switzerland); Shengelaya, A [Physik-Institut der Universitaet Zuerich, CH-8057 Zurich (Switzerland); Morenzoni, E [Laboratory for Muon Spin Spectroscopy, Paul Scherrer Institute, CH-5232 Villigen PSI (Switzerland); Conder, K [Laboratory for Neutron Scattering, ETH Zuerich and PSI Villigen, CH-5232 Villigen PSI (Switzerland); Savic, I M [Faculty of Physics, University of Belgrade, 11001 Belgrade (Serbia and Montenegro); Keller, H [Physik-Institut der Universitaet Zuerich, CH-8057 Zurich (Switzerland)

    2004-10-13

    Muon spin rotation ({mu}SR) studies of the oxygen isotope ({sup 16}O/{sup 18}O) effect (OIE) on the in-plane magnetic field penetration depth {lambda}{sub ab} in cuprate high-temperature superconductors (HTS) are presented. First, the doping dependence of the OIE on the transition temperature T{sub c} in various HTS is briefly discussed. It is observed that different cuprate families show similar doping dependences of the OIE on T{sub c}. Then, bulk {mu}SR, low-energy {mu}SR, and magnetization studies of the total and site-selective OIE on {lambda}{sub ab} are described in some detail. A substantial OIE on {lambda}{sub ab} was observed in various cuprate families at all doping levels, suggesting that cuprate HTS are non-adiabatic superconductors. The experiments clearly demonstrate that the total OIE on T{sub c} and {lambda}{sub ab} arise from the oxygen sites within the superconducting CuO{sub 2} planes, demonstrating that the phonon modes involving the movement of planar oxygen are dominantly coupled to the supercarriers. Finally, it is shown that the OIE on T{sub c} and {lambda}{sub ab} exhibit a relation that appears to be generic for different families of cuprate HTS. The observation of these unusual isotope effects implies that lattice effects play an essential role in cuprate HTS and have to be considered in any realistic model of high-temperature superconductivity.

  10. Percutaneous penetration studies for risk assessment

    DEFF Research Database (Denmark)

    Sartorelli, Vittorio; Andersen, Helle Raun; Angerer, Jürgen

    2000-01-01

    . In order to predict the systemic risk of dermally absorbed chemicals and to enable agencies to set safety standards, data is needed on the rates of percutaneous penetration of important chemicals. Standardization of in vitro tests and comparison of their results with the in vivo data could produce...... internationally accepted penetration rates and/or absorption percentages very useful for regulatory toxicology. The work of the Percutaneous Penetration Subgroup of EC Dermal Exposure Network has been focussed on the standardization and validation of in vitro experiments, necessary to obtain internationally...... accepted penetration rates for regulatory purposes. The members of the Subgroup analyzed the guidelines on percutaneous penetration in vitro studies presented by various organizations and suggested a standardization of in vitro models for percutaneous penetration taking into account their individual...

  11. Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams

    International Nuclear Information System (INIS)

    Russell, K.R.; Saxner, M.; Ahnesjoe, A.; Montelius, A.; Grusell, E.; Dahlgren, C.V.

    2000-01-01

    The implementation of two algorithms for calculating dose distributions for radiation therapy treatment planning of intermediate energy proton beams is described. A pencil kernel algorithm and a depth penetration algorithm have been incorporated into a commercial three-dimensional treatment planning system (Helax-TMS, Helax AB, Sweden) to allow conformal planning techniques using irregularly shaped fields, proton range modulation, range modification and dose calculation for non-coplanar beams. The pencil kernel algorithm is developed from the Fermi-Eyges formalism and Moliere multiple-scattering theory with range straggling corrections applied. The depth penetration algorithm is based on the energy loss in the continuous slowing down approximation with simple correction factors applied to the beam penumbra region and has been implemented for fast, interactive treatment planning. Modelling of the effects of air gaps and range modifying device thickness and position are implicit to both algorithms. Measured and calculated dose values are compared for a therapeutic proton beam in both homogeneous and heterogeneous phantoms of varying complexity. Both algorithms model the beam penumbra as a function of depth in a homogeneous phantom with acceptable accuracy. Results show that the pencil kernel algorithm is required for modelling the dose perturbation effects from scattering in heterogeneous media. (author)

  12. Multiaxial stress analysis taking account of the penetration depth of x-rays, (1)

    International Nuclear Information System (INIS)

    Sasaki, Toshihiko; Yoshioka, Yasuo; Kuramoto, Makoto.

    1983-01-01

    The new theory of X-ray multiaxial stress measurement is proposed. This method takes accounts of the influence concerning to the stress gradient and to the dependence of the penetration depth of X-rays upon the incidence angle. As a basic assumption, it's assumed that (1) stress gradient is linear in respect to the depth from the specimen surface, (2) the penetration depth of X-rays shows linear dependence upon sin 2 PSI, and (3) the lattice strain determined by X-rays corresponds to the weighted averaging strain on the intensity of the diffracted X-rays. Consequently, the stress state within the thin layer near to the surface is expressed by making use of three surface stresses and six stress gradients in this theory. It was proved that these nine stress elements were able to be solved through X-ray method by applying ''the integral method'' proposed by Lode and Peiter in 1976. The verification of the validity on this method was carried out through the numerical simulation and residual stress measurement of a ground S55C. As a result, it was found that this method could get a satisfactory accuracy. This method can estimate the multiaxial stress distribution within the surface layer nondestructively. (author)

  13. An EPR methodology for measuring the London penetration depth for the ceramic superconductors

    Science.gov (United States)

    Rakvin, B.; Mahl, T. A.; Dalal, N. S.

    1990-01-01

    The use is discussed of electron paramagnetic resonance (EPR) as a quick and easily accessible method for measuring the London penetration depth, lambda for the high T(sub c) superconductors. The method utilizes the broadening of the EPR signal, due to the emergence of the magnetic flux lattice, of a free radical adsorbed on the surface of the sample. The second moment, of the EPR signal below T(sub c) is fitted to the Brandt equation for a simple triangular lattice. The precision of this method compares quite favorably with those of the more standard methods such as micro sup(+)SR, Neutron scattering, and magnetic susceptibility.

  14. Experimental determination of the temperature-dependent penetration depth in V3Si

    International Nuclear Information System (INIS)

    Christen, D.K.; Kerchner, H.R.; Sekula, S.T.; Chang, Y.K.

    1984-03-01

    Small angle neutron diffraction from the flux-line lattice (FLL) in a high quality, single crystal of superconducting V 3 Si has been used to deduce the low-field penetration depth lambda (T). An absolute determination is possible because the FLL form factor F/sub hk/ is essentially single-valued in the scattering vector magnitude absolute value of K/sub hk/, as well as nearly London-like at low field. We obtain lambda (0) = 102 +- 1 nm, 20% to 30% larger than previous determinations of the London penetration depth lambda/sub L/ (0). The temperature dependence of lambda (T) is found to deviate from that of the BCS theory. An assessment of the data indicates the most prominent source of the discrepancy is due to strong electron-phonon coupling, and we find 2Δ(0)/k/sub B/T/sub c/ = 3.88 +- 0.07, in reasonable agreement with values found in the literature

  15. Measurement of the magnetic penetration depth in p-doped superconducting diamond films

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Lorenz; Brunner, Markus C.P.; Schneider, Ina; Kronfeldner, Klaus [University of Regensburg (Germany); Bousquet, Jessica; Bustarret, Etienne; Strunk, Christoph [Institut Neel, Grenoble (France)

    2016-07-01

    Boron-doped diamond becomes superconducting once a critical doping concentration of 4.5 x 10{sup 20} cm{sup -3} is reached. Mutual inductance measurements with a two-coil setup have been performed to determine the magnetic penetration depth λ(T), which is a measure for the superfluid stiffnes θ ∝ 1/λ{sup 2}(T). Two superconducting p-doped diamond films with thicknesses of 145 nm and 345 nm were investigated. At low temperatures these values agree reasonably with the values expected within BCS-theory using T{sub c}, carrier density and mean free path determined from electric transport measurements. Magnetic penetration depths of 3.7 μm for the thinner and 2.6 μm for the thicker film have been found. λ decreases and accordingly θ increases with increasing film thickness. On the other hand, the superfluid stiffness drops by a factor of 2 or even more at T{sub c}/2, i.e., much faster than expected from BCS-theory, but remains finite between T{sub c}/2 < T < T{sub c}. At present it is unclear, whether this behavior results from the proliferation of phase fluctuations already far below T{sub c} or from a spatial inhomogeneity of the films.

  16. Temperature Dependence of Apparent Respiratory Quotients and Oxygen Penetration Depth in Contrasting Lake Sediments

    Science.gov (United States)

    Sobek, Sebastian; Gudasz, Cristian; Koehler, Birgit; Tranvik, Lars J.; Bastviken, David; Morales-Pineda, María.

    2017-11-01

    Lake sediments constitute an important compartment in the carbon cycle of lakes, by burying carbon over geological timescales and by production and emission of greenhouse gases. The degradation of organic carbon (OC) in lake sediments is linked to both temperature and oxygen (O2), but the interactive nature of this regulation has not been studied in lake sediments in a quantitative way. We present the first systematic investigation of the effects of temperature on the apparent respiratory quotient (RQ, i.e., the molar ratio between carbon dioxide (CO2) production and O2 consumption) in two contrasting lake sediments. Laboratory incubations of sediment cores of a humic lake and an eutrophic lake across a 1-21°C temperature gradient over 157 days revealed that both CO2 production and O2 consumption were positively, exponentially, and similarly dependent on temperature. The apparent RQ differed significantly between the lake sediments (0.63 ± 0.26 and 0.99 ± 0.28 in the humic and the eutrophic lake, respectively; mean ± SD) and was significantly and positively related to temperature. The O2 penetration depth into the sediment varied by a factor of 2 over the 1-21°C temperature range and was significantly, negatively, and similarly related to temperature in both lake sediments. Accordingly, increasing temperature may influence the overall extent of OC degradation in lake sediments by limiting O2 supply to aerobic microbial respiration to the topmost sediment layer, resulting in a concomitant shift to less effective anaerobic degradation pathways. This suggests that temperature may represent a key controlling factor of the OC burial efficiency in lake sediments.

  17. Evidence of weak pair coupling in the penetration depth of bi-based high-Tc superconductors

    International Nuclear Information System (INIS)

    Thompson, J.R.; Sun, Yang Ren; Ossandon, J.G.; Christen, D.K.; Chakoumakos, B.C.; Sales, B.C.; Kerchner, H.R.; Sonder, E.

    1990-01-01

    The magnetic penetration depth λ(T) has been investigated in Bi(Pb)SrCaCuO high-T c compounds having 2- and 3-layers of copper-oxygen per unit cell. Studies of the magnetization in the vortex state were employed and the results were compared with weak and strong coupling calculations. The temperature dependence of λ is described well by BCS theory in the clean limit, giving evidence for weak pair coupling in this family of materials. For the short component of the λ tensor, we obtain values of 292 and 220 nm (T = 0) for Bi-2212 and (BiPb)-2223, respectively

  18. A Study of Crystalline Mechanism of Penetration Sealer Materials.

    Science.gov (United States)

    Teng, Li-Wei; Huang, Ran; Chen, Jie; Cheng, An; Hsu, Hui-Mi

    2014-01-14

    It is quite common to dispense a topping material like crystalline penetration sealer materials (CPSM) onto the surface of a plastic substance such as concrete to extend its service life span by surface protections from outside breakthrough. The CPSM can penetrate into the existing pores or possible cracks in such a way that it may form crystals to block the potential paths which provide breakthrough for any unknown materials. This study investigated the crystalline mechanism formed in the part of concrete penetrated by the CPSM. We analyzed the chemical composites, in order to identify the mechanism of CPSM and to evaluate the penetrated depth. As shown in the results, SEM observes the acicular-structured crystals filling capillary pores for mortar substrate of the internal microstructure beneath the concrete surface; meanwhile, XRD and FT-IR showed the main hydration products of CPSM to be C-S-H gel and CaCO₃. Besides, MIP also shows CPSM with the ability to clog capillary pores of mortar substrate; thus, it reduces porosity, and appears to benefit in sealing pores or cracks. The depth of CPSM penetration capability indicated by TGA shows 0-10 mm of sealer layer beneath the concrete surface.

  19. A Study of Crystalline Mechanism of Penetration Sealer Materials

    Directory of Open Access Journals (Sweden)

    Li-Wei Teng

    2014-01-01

    Full Text Available It is quite common to dispense a topping material like crystalline penetration sealer materials (CPSM onto the surface of a plastic substance such as concrete to extend its service life span by surface protections from outside breakthrough. The CPSM can penetrate into the existing pores or possible cracks in such a way that it may form crystals to block the potential paths which provide breakthrough for any unknown materials. This study investigated the crystalline mechanism formed in the part of concrete penetrated by the CPSM. We analyzed the chemical composites, in order to identify the mechanism of CPSM and to evaluate the penetrated depth. As shown in the results, SEM observes the acicular-structured crystals filling capillary pores for mortar substrate of the internal microstructure beneath the concrete surface; meanwhile, XRD and FT-IR showed the main hydration products of CPSM to be C-S-H gel and CaCO3. Besides, MIP also shows CPSM with the ability to clog capillary pores of mortar substrate; thus, it reduces porosity, and appears to benefit in sealing pores or cracks. The depth of CPSM penetration capability indicated by TGA shows 0–10 mm of sealer layer beneath the concrete surface.

  20. London penetration depth and thermal fluctuations in the sulphur hydride 203 K superconductor

    Energy Technology Data Exchange (ETDEWEB)

    Talantsev, E.F.; Crump, W.P. [Robinson Research Institute, Victoria University of Wellington, Lower Hutt (New Zealand); Storey, J.G.; Tallon, J.L. [Robinson Research Institute, Victoria University of Wellington, Lower Hutt (New Zealand); MacDiarmid Institute for Advanced Materials and Nanotechnology, Lower Hutt (New Zealand)

    2017-03-15

    Recently, compressed H{sub 2}S has been shown to become superconducting at 203 K under a pressure of 155 GPa. One might expect fluctuations to dominate at such temperatures. Using the magnetisation critical current, we determine the ground-state London penetration depth, λ{sub 0} = 189 nm, and the superconducting energy gap, Δ{sub 0} = 27.8 meV, and find these parameters are similar to those of cuprate superconductors. We also determine the fluctuation temperature scale, T{sub fluc} = 1470 K, which shows that, unlike the cuprates, T{sub c} of the hydride is not limited by fluctuations. This is due to its three dimensionality and suggests the search for better superconductors should refocus on three-dimensional systems where the inevitable thermal fluctuations are less likely to reduce the observed T{sub c}. (copyright 2016 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. In-plane magnetic penetration depth of superconducting CaKFe4As4

    Science.gov (United States)

    Khasanov, Rustem; Meier, William R.; Wu, Yun; Mou, Daixiang; Bud'ko, Sergey L.; Eremin, Ilya; Luetkens, Hubertus; Kaminski, Adam; Canfield, Paul C.; Amato, Alex

    2018-04-01

    The temperature dependence of the in-plane magnetic penetration depth (λa b) in an extensively characterized sample of superconducting CaKFe4As4(Tc≃35 K ) was investigated using muon-spin rotation (μ SR ). A comparison of λab -2(T ) measured by μ SR with the one inferred from angle-resolved photoemission spectroscopy (ARPES) data confirms the presence of multiple gaps at the Fermi level. An agreement between μ SR and ARPES requires the presence of additional bands, which are not resolved by ARPES experiments. These bands are characterized by small superconducting gaps with an average zero-temperature value of Δ0=2.4 (2 ) meV . Our data suggest that in CaKFe4As4 the s± order parameter symmetry acquires a more sophisticated form by allowing a sign change not only between electron and hole pockets, but also within pockets of similar type.

  2. An investigation into the depth of penetration of low level laser therapy through the equine tendon in vivo

    Directory of Open Access Journals (Sweden)

    Ryan Teresa

    2007-05-01

    Full Text Available Abstract Low level laser therapy (LLLT is frequently used in the treatment of wounds, soft tissue injury and in pain management. The exact penetration depth of LLLT in human tissue remains unspecified. Similar uncertainty regarding penetration depth arises in treating animals. This study was designed to test the hypothesis that transmission of LLLT in horses is increased by clipping the hair and/or by cleaning the area to be treated with alcohol, but is unaffected by coat colour. A LLLT probe (810 nm, 500 mW was applied to the medial aspect of the superficial flexor tendon of seventeen equine forelimbs in vivo. A light sensor was applied to the lateral aspect, directly opposite the laser probe to measure the amount of light transmitted. Light transmission was not affected by individual horse, coat colour or leg. However, it was associated with leg condition (F = 4.42, p = 0.0032. Tendons clipped dry and clipped and cleaned with alcohol, were both associated with greater transmission of light than the unprepared state. Use of alcohol without clipping was not associated with an increase in light transmission. These results suggest that, when applying laser to a subcutaneous structure in the horse, the area should be clipped and cleaned beforehand.

  3. The predicting ultimate of joint withdrawal resistance constructed of plywood with regression models application according to diameter and penetrating depth

    Directory of Open Access Journals (Sweden)

    Sadegh Maleki

    2013-11-01

    Full Text Available The goal of this study was to present regression models for predicting resistance of joints made with screw and plywood members. Joint members were out of hardwood plywood that were 19 mm in thickness. Two types of screws including coarse and fine thread drywall screw with 3.5, 4 and 5mm in diameter and sheet metal screw with 4 and 5mm were used. Results have shown that withdrawal resistance of screw was increased by increasing of screws, diameter and penetrating depth. Joints fabricated with coarse thread drywall screws were higher than those of fine thread drywall screws. Finally, average joint withdrawal resistance of screwed could be predicted by means of the expressions Wc=2.127×D1.072×P0.520 for coarse thread drywall screws and Wf=1.377×D1.156×P0.581 for fine thread drywall screws by taking account the diameter and penetrating depth. The difference of the observed and predicted data showed that developed models have a good correlation with actual experimental measurements.

  4. Penetration-depth calculations in the ab and c directions in a layered S/N superconductor

    International Nuclear Information System (INIS)

    Atkinson, W.A.; Carbotte, J.P.

    1995-01-01

    We present the results of calculations of the penetration depths λ ab and λ c (the subscripts refer to the direction of the screening currents). Our model is a layered superconducting/normal metal (S/N) model, in which the two types of layers are stacked in alternating fashion. The S and N layers are coupled in a coherent fashion and the N layer is driven superconducting by a proximity effect. We calculate the penetration depths for both d-wave and s-wave order parameters for a range of interlayer coupling strengths, and we discuss the effect that the interlayer coupling has on the temperature dependence of the penetration depths. We finish by comparing our results with experimental observations of YBa 2 Cu 3 O 7

  5. Effect of impurity scattering on the low temperature magnetic penetration depth of a nonlocal and nonlinear d-wave superconductor

    International Nuclear Information System (INIS)

    Yavary, H.

    2006-01-01

    The magnetic penetration depth of a quasi-two dimensional d-wave superconductor in the presence of nonlineary, nonlocality, and impurity effects is investigated by using Green's function method. It is shown that a d-wave superconductor would inevitably avoid the violation of the Nernst theorem by creating a T 2 term in its penetration depth through a competition of nonlinear, nonlocal, and impurity effects and this system may be stable at low temperatures. I also show that in the impure sample at low temperatures, T < T * ∝ γ the impurity effect determines the temperature dependence of the penetration depth, i.e., nonlocal and nonlinear effects are completely masked by impurities

  6. Microscopic measurement of penetration depth in YBa2Cu3O7-δ thin films by scanning Hall probe microscopy

    International Nuclear Information System (INIS)

    Oral, A.; Bending, S.J.; Humphreys, R.G.; Henini, M.

    1997-01-01

    We have used a low noise scanning Hall probe microscope to measure the penetration depth microscopically in a YBa 2 Cu 3 O 7-δ thin film as a function of temperature. The instrument has high magnetic field (approx. 2.9x10 -8 T Hz -1/2 at 77 K) and spatial resolution (approx. 0.85 μm). Magnetic field profiles of single vortices in the superconducting film have been successfully measured and the microscopic penetration depth of the superconductor has been extracted. We find surprisingly large variations in values of λ for different vortices within the scanning field. (author)

  7. Plasma penetration depth and mechanical properties of atmospheric plasma-treated 3D aramid woven composites

    International Nuclear Information System (INIS)

    Chen, X.; Yao, L.; Xue, J.; Zhao, D.; Lan, Y.; Qian, X.; Wang, C.X.; Qiu, Y.

    2008-01-01

    Three-dimensional aramid woven fabrics were treated with atmospheric pressure plasmas, on one side or both sides to determine the plasma penetration depth in the 3D fabrics and the influences on final composite mechanical properties. The properties of the fibers from different layers of the single side treated fabrics, including surface morphology, chemical composition, wettability and adhesion properties were investigated using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), contact angle measurement and microbond tests. Meanwhile, flexural properties of the composites reinforced with the fabrics untreated and treated on both sides were compared using three-point bending tests. The results showed that the fibers from the outer most surface layer of the fabric had a significant improvement in their surface roughness, chemical bonding, wettability and adhesion properties after plasma treatment; the treatment effect gradually diminished for the fibers in the inner layers. In the third layer, the fiber properties remained approximately the same to those of the control. In addition, three-point bending tests indicated that the 3D aramid composite had an increase of 11% in flexural strength and 12% in flexural modulus after the plasma treatment. These results indicate that composite mechanical properties can be improved by the direct fabric treatment instead of fiber treatment with plasmas if the fabric is less than four layers thick

  8. Unstability of the Fulde-Ferrell state in d-wave superconductors by calculating the magnetic penetration depth

    International Nuclear Information System (INIS)

    Rabani, H.; Shahzamanian, M.A.; Yavary, H.

    2007-01-01

    Full text: Fulde, Ferrell, Larkin and Ovchnnikov (FFLO), first proposed the possibility that a superconducting state with a periodic spatial variation of the gap parameter would become stable when a large Zeeman splinting is present [1,2]. The order parameter varies periodically in space when the Pauli paramagnetism or the Zeeman term dominates the orbital effect. The Zeeman splitting could be due to either a strong magnetic field or an internal exchange field. Under these fields there is a splitting of the Fermi surfaces of spin up and spin down electrons, and the condensed pair has a non-zero total momentum, 2q, which causes the phase of the superconducting order parameter to vary. This state is known as the FF state. We determine the penetration depth of the Fulde-Ferrell State (FF) for quasi-two dimensional (2D) d-wave superconductor by calculating the electromagnetic nonlocal kernel response function. The behavior of the penetration depth at low temperatures is an important probe to determine the stability of the FF state. We start from a mean field Hamiltonian for the FF state and we calculate the electromagnetic nonlocal response tensor relating the current density to an applied vector potential to determine the magnetic penetration depth. We show that a linear T dependence of the magnetic penetration depth in the FF state superconductor violates indeed the third law of thermodynamics and the FF state is unstable due to Nernst theorem. (authors)

  9. Penetration depth λ(T) of YBa2Cu3O7-δ films determined from the kinetic inductance

    International Nuclear Information System (INIS)

    Lee, J.; Lemberger, T.R.

    1993-01-01

    We examine the temperature dependence of the magnetic penetration depth λ(T) of YBa 2 Cu 3 O 7-δ , determined from the kinetic inductance of a film patterned into a long meander line. This technique has sufficient sensitivity to study λ(T) to lower temperatures than have been examined previously. A numerical model which includes both the magnetic and kinetic inductances of the samples extracts λ(T) from the measured voltage. In reasonable agreement with other measurements, λ(0)∼2100 A is deduced from fitting λ(0) 2 /λ(T) 2 to the function 1-(T/T c ) 2 for T/T c ≥0.4. We find λ(T)/λ(0)-1 is proportional to (T/T c ) 2 for 0.06 ≤T/T c ≤0.4

  10. Variation of energy absorption buildup factors with incident photon energy and penetration depth for some commonly used solvents

    International Nuclear Information System (INIS)

    Singh, Parjit S.; Singh, Tejbir; Kaur, Paramjeet

    2008-01-01

    G.P. fitting method has been used to compute energy absorption buildup factor of some commonly used solvents such as acetonitrile (C 4 H 3 N), butanol (C 4 H 9 OH), chlorobenzene (C 6 H 5 Cl), diethyl ether (C 4 H 10 O), ethanol (C 2 H 5 OH), methanol (CH 3 OH), propanol (C 3 H 7 OH) and water (H 2 O) for the wide energy range (0.015-15.0 MeV) up to the penetration depth of 10 mean free path. The variation of energy absorption buildup factor with chemical composition as well as incident photon energy for the selected solvents has been studied. It has been observed that the maximum value of energy absorption buildup factors shifts to the slightly higher incident photon energy with the increase in equivalent atomic number of the solvent and the solvent with least equivalent atomic number possesses the maximum value of energy absorption buildup factor

  11. A numerical study on the disturbance of explosive reactive armors to jet penetration

    Directory of Open Access Journals (Sweden)

    Xiang-dong Li

    2014-03-01

    Full Text Available The disturbance of flat and V-shaped sandwich reactive armor configurations to shaped-charge jet is studied by a numerical approach. The disturbing and cutting effects of the two reactive armor configurations to the jet are successfully captured. The predicted disturbance characteristics and patterns are in fairly good agreement with the X-ray photographic observations. The residual depth of penetration into a semi-infinitive homogeneous steel target behind the reactive armor is computed for a series of jet/armor parameters. For the flat configuration, it is demonstrated that the residual penetration depth is not significantly reduced for a normal impact while it is reduced up to 75% for an oblique impact. In comparison, the V-shaped configuration reduces the penetration depth of the jet to 90%, and it is observed that the penetration depth is not sensitive to the V-shaped angle.

  12. Measurement of the penetration depth and coherence length of MgB2 in all directions using transmission electron microscopy

    DEFF Research Database (Denmark)

    Loudon, J. C.; Yazdi, Sadegh; Kasama, Takeshi

    2015-01-01

    We demonstrate that images of flux vortices in a superconductor taken with a transmission electron microscope can be used to measure the penetration depth and coherence length in all directions at the same temperature and magnetic field. This is particularly useful for MgB2, where these quantities...... vary with the applied magnetic field and values are difficult to obtain at low field or in the c direction. We obtained images of flux vortices from a MgB2 single crystal cut in the ac plane by focused ion beam milling and tilted to 45 degrees. with respect to the electron beam about...... the crystallographic a axis. A new method was developed to simulate these images that accounted for vortices with a nonzero core in a thin, anisotropic superconductor and a simplex algorithm was used to make a quantitative comparison between the images and simulations to measure the penetration depths and coherence...

  13. Effective depth-of-penetration range due to hardness variation for different lots of nominally identical target material

    Directory of Open Access Journals (Sweden)

    Patrick Frueh

    2016-04-01

    A linear regression analysis of penetration vs. hardness shows that a target hardness increase within the given range of 280–330 BHN may result in a reduction of penetration depth of about 5.8 mm at constant velocity. This is equal to a change of −12% at an impact velocity of 1250 m/s. A multiple linear regression analysis included also the influence of yaw angle and impact velocity. It shows that small yaw angles and slight variations of impact velocities provide a smaller variation of the semi-infinite penetration depths than a variation of target hardness within a typical specification span of 50 BHN. For such a span a change in penetration of approximately −4.8 mm due to hardness variation is found, whereas 1° of yaw angle or −10 m/s of velocity variation gives a change of about −1.0 mm respectively −0.9 mm. For the given example, the overwhelming part of the variation is to be attributed to hardness effects – 4.8 mm out of 5.8 mm (83%. For nominally identical target material the target hardness thus influences the ballistic test results more severely than the typical scatter in impact conditions.

  14. Anisotropy of the penetration depth in La2-xSrxCuO4 in underdoped and overdoped regions

    Science.gov (United States)

    Zaleski, A. J.; Klamut, J.

    1999-12-01

    We present the results of measurements of the penetration depth anisotropy in pulverized, ceramic La2-xSrxCuO4. The measurements were carried out for x = 0.08, 0.1, 0.125, 0.15 and 0.2. The powdered samples, immersed in wax, were magnetically oriented in a static magnetic field of 10 T. The penetration depth in the a-b plane, icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>ab, and perpendicular to it, icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>icons/Journals/Common/perp" ALT="perp" ALIGN="MIDDLE"/>, were derived from alternating-current susceptibility measurements. For underdoped samples they both vary linearly with temperature (for the low-temperature region), while for the samples from the overdoped region the measured points can be fitted by an exponential function. These results support Uemura's picture (Uemura Y J 1997 Physica C 282-287 194) of crossover from Bose-Einstein condensation to a Bardeen-Cooper-Schrieffer mechanism of superconductivity. The penetration depth values extrapolated to T = 0 may be described by a quadratic function of the strontium concentration (for both icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>ab and icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>icons/Journals/Common/perp" ALT="perp" ALIGN="MIDDLE"/>). The anisotropy of the penetration depth as a function of the substitution shows a similar dependence to the critical temperature Tc(x).

  15. There’s plenty of light at the bottom: statistics of photon penetration depth in random media

    Science.gov (United States)

    Martelli, Fabrizio; Binzoni, Tiziano; Pifferi, Antonio; Spinelli, Lorenzo; Farina, Andrea; Torricelli, Alessandro

    2016-01-01

    We propose a comprehensive statistical approach describing the penetration depth of light in random media. The presented theory exploits the concept of probability density function f(z|ρ, t) for the maximum depth reached by the photons that are eventually re-emitted from the surface of the medium at distance ρ and time t. Analytical formulas for f, for the mean maximum depth 〈zmax〉 and for the mean average depth reached by the detected photons at the surface of a diffusive slab are derived within the framework of the diffusion approximation to the radiative transfer equation, both in the time domain and the continuous wave domain. Validation of the theory by means of comparisons with Monte Carlo simulations is also presented. The results are of interest for many research fields such as biomedical optics, advanced microscopy and disordered photonics. PMID:27256988

  16. Sub?40?fs, 1060?nm Yb?fiber laser enhances penetration depth in nonlinear optical microscopy of human skin

    OpenAIRE

    Balu, Mihaela; Saytashev, Ilyas; Hou, Jue; Dantus, Marcos; Tromberg, Bruce J.

    2015-01-01

    © 2015 The Authors. Advancing the practical utility of nonlinear optical microscopy requires continued improvement in imaging depth and contrast. We evaluated second-harmonic generation (SHG) and third-harmonic generation images from ex vivo human skin and showed that a sub-40 fs, 1060-nm Yb-fiber laser can enhance SHG penetration depth by up to 80% compared to a > 100 fs, 800 nm Ti:sapphire source. These results demonstrate the potential of fiber-based laser systems to address a key perform...

  17. Measurement of residual stress in a sphere by x-ray under the consideration of its penetration depth

    International Nuclear Information System (INIS)

    Doi, Osamu; Ukai, Takayoshi

    1981-01-01

    It was pointed out in the case of a plate that when stress gradient is large, the use of the X-ray with large penetration depth caused large measurement error. In this paper, the theoretical equations for measuring the residual stress in a sphere with X-ray, taking penetration depth into account, are proposed, and the example of application is shown. As the method of measuring the residual stress in a hollow sphere with X-ray, only the method of combining external surface removal and external surface irradiation is practically in use. It was assumed that a sphere is isotropic, and that the residual stress is a function of the radius only. First, the theory of measuring the residual stress in a sphere with X-ray taking penetration depth into account is explained, and the equations for calculating the residual stresses in tangential and radial directions are derived. As the example of applying this theory, the distribution of the residual stress in a steel ball for a ball bearing was measured with Cr characteristic X-ray. The ball of 30 mm diameter was made of high-carbon chromium bearing steel, grade 2, (JIS SUJ2) and quenched and tempered. The removal of the thin layer was made by chemical etching and electrolysis. The measured values and the calculated values are shown. (Kako, I.)

  18. The Impact of Microwave Penetration Depth on the Process of Heating the Moulding Sand with Sodium Silicate

    Directory of Open Access Journals (Sweden)

    Nowak D.

    2017-12-01

    Full Text Available This paper presents the impact of microwave penetration depth on the process of heating the moulding sand with sodium silicate. For each material it is affected by: the wavelength in vacuum and the real and imaginary components of the relative complex electrical permittivity εr for a selected measurement frequency. Since the components are not constant values and they change depending on the electrical parameters of materials and the frequency of the electromagnetic wave, it is indispensable to carry out laboratory measurements to determine them. Moreover, the electrical parameters of materials are also affected by: temperature, packing degree, humidity and conductivity. The measurements of the dielectric properties of moulding sand with sodium silicate was carried out using the perturbation method on a stand of waveguide resonance cavity. The real and imaginary components of the relative complex electrical permittivity was determined for moulding sand at various contents of sodium silicate and at various packing degrees of the samples. On the basis of the results the microwave penetration depth of moulding sand with sodium silicate was established. Relative literature contains no such data that would be essential to predicting an effective process of microwave heating of moulding sand with sodium silicate. Both the packing degree and the amount of sodium silicate in moulding sand turned out to affect the penetration depth, which directly translates into microwave power density distribution in the process of microwave heating of moulding sand with sodium silicate.

  19. Muon-spin-rotation measurements of the London penetration depths in YBa2Cu3O6.97

    International Nuclear Information System (INIS)

    Puempin, B.; Keller, H.; Kuendig, W.; Odermatt, W.; Savic, I.M.; Schneider, J.W.; Simmler, H.; Zimmermann, P.; Kaldis, E.; Rusiecki, S.; Maeno, Y.; Rossel, C.

    1990-01-01

    Muon-spin-rotation (μSR) experiments on a high-quality sintered YBa 2 Cu 3 O x sample [x=6.970(1)] were performed, in order to obtain an accurate knowledge of the magnitude and the temperature dependence of the magnetic penetration depth in this copper oxide superconductor. Special attention was given to the data analysis. In particular, the systematic errors introduced by different types of analyses were estimated. Our results show that the temperature dependence of the effective penetration depth λ eff into the sintered sample is well described by the two-fluid model, with λ eff (0)=155(10) nm. This behavior of λ eff (T) is consistent with conventional s-wave pairing. With the anisotropy ratio γ=λ c /λ ab =5(1) measured in a previous μSR experiment, the penetration depths λ ab (0)=130(10) nm and λ c (0)=500--800 nm (parallel and perpendicular to the CuO 2 planes, respectively) were extracted. Our results are compared with those obtained by other experimental techniques and theoretical predictions

  20. Variation of energy absorption and exposure buildup factors with incident photon energy and penetration depth for boro-tellurite (B2O3-TeO2) glasses

    Science.gov (United States)

    Sayyed, M. I.; Elhouichet, H.

    2017-01-01

    The gamma ray energy absorption (EABF) and exposure buildup factors (EBF) of (100-x)TeO2-xB2O3 glass systems (where x=5, 10, 15, 20, 22.5 and 25 mol%) have been calculated in the energy region 0.015-15 MeV up to a penetration depth of 40 mfp (mean free path). The five parameters (G-P) fitting method has been used to estimate both EABF and EBF values. Variations of EABF and EBF with incident photon energy and penetration depth have been studied. It was found that EABF and EBF values were higher in the intermediate energy region, for all the glass systems. Furthermore, boro-tellurite glass with 5 mol% B2O3, was found to present the lowest EABF and EBF values, hence it is superior gamma-ray shielding material. The results indicate that the boro-tellurite glasses can be used as radiation shielding materials.

  1. Determination of penetration depth at high velocity impact using finite element method and artificial neural network tools

    Directory of Open Access Journals (Sweden)

    Namık KılıÇ

    2015-06-01

    Full Text Available Determination of ballistic performance of an armor solution is a complicated task and evolved significantly with the application of finite element methods (FEM in this research field. The traditional armor design studies performed with FEM requires sophisticated procedures and intensive computational effort, therefore simpler and accurate numerical approaches are always worthwhile to decrease armor development time. This study aims to apply a hybrid method using FEM simulation and artificial neural network (ANN analysis to approximate ballistic limit thickness for armor steels. To achieve this objective, a predictive model based on the artificial neural networks is developed to determine ballistic resistance of high hardness armor steels against 7.62 mm armor piercing ammunition. In this methodology, the FEM simulations are used to create training cases for Multilayer Perceptron (MLP three layer networks. In order to validate FE simulation methodology, ballistic shot tests on 20 mm thickness target were performed according to standard Stanag 4569. Afterwards, the successfully trained ANN(s is used to predict the ballistic limit thickness of 500 HB high hardness steel armor. Results show that even with limited number of data, FEM-ANN approach can be used to predict ballistic penetration depth with adequate accuracy.

  2. Measuring soil frost depth in forest ecosystems with ground penetrating radar

    Science.gov (United States)

    John R. Butnor; John L. Campbell; James B. Shanley; Stanley. Zarnoch

    2014-01-01

    Soil frost depth in forest ecosystems can be variable and depends largely on early winter air temperatures and the amount and timing of snowfall. A thorough evaluation of ecological responses to seasonally frozen ground is hampered by our inability to adequately characterize the frequency, depth, duration and intensity of soil frost events. We evaluated the use of...

  3. Variation of energy absorption buildup factors with incident photon energy and penetration depth for some commonly used solvents

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Parjit S. [Department of Physics, Punjabi University, Patiala 147 002 (India)], E-mail: dr_parjit@hotmail.com; Singh, Tejbir [Department of Physics, Lovely Professional University, Phagwara 144 402 (India); Kaur, Paramjeet [IAS and Allied Services Training Centre, Punjabi University, Patiala 147 002 (India)

    2008-06-15

    G.P. fitting method has been used to compute energy absorption buildup factor of some commonly used solvents such as acetonitrile (C{sub 4}H{sub 3}N), butanol (C{sub 4}H{sub 9}OH), chlorobenzene (C{sub 6}H{sub 5}Cl), diethyl ether (C{sub 4}H{sub 10}O), ethanol (C{sub 2}H{sub 5}OH), methanol (CH{sub 3}OH), propanol (C{sub 3}H{sub 7}OH) and water (H{sub 2}O) for the wide energy range (0.015-15.0 MeV) up to the penetration depth of 10 mean free path. The variation of energy absorption buildup factor with chemical composition as well as incident photon energy for the selected solvents has been studied. It has been observed that the maximum value of energy absorption buildup factors shifts to the slightly higher incident photon energy with the increase in equivalent atomic number of the solvent and the solvent with least equivalent atomic number possesses the maximum value of energy absorption buildup factor.

  4. Penetration depth measurement of a 6 MeV electron beam in water by magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    B. E. Hammer

    2011-11-01

    Full Text Available We demonstrate magnetic resonance imaging (MRI visualization of a 6 MeV electron beam in ferrous-doped water; a 25 mm penetration depth was measured. Time domain nuclear magnetic resonance was used to investigate the effect of generated free radicals on the free induction decay (FID in nondoped water; no apparent effects to the FID were observed. We show that MRI visualization of charged particle beams used in medical applications will require exogenous agents to provide contrast enhancement.

  5. Effects of inserted depth of wall penetration on basal stability of foundation pits

    Science.gov (United States)

    Zhou, Aizhao; Shen, Hao; Sun, Jinguo

    2017-05-01

    Evaluation of basal heave stability is one of important design checks for excavations in soft clays. The commonly used classical calculation method based on limit equilibrium theory and the safety coefficient formula recommended by the current code, do not consider the influence of supporting structure of foundation pit depth heave stability, which results in conservative. Considering the wall stiffness and strength, the effective stress changes in different depth of soil, the frictional resistance between the retaining wall and the passive zone, the vertical shear resistance of the soil behind the wall and other factors. The modified safety factor calculation formula of foundation pit stability is presented, comparison analysis of calculation method combined with examples. The calculation results show that the safety factor of foundation pit stability is improved considering the influence of supporting structure depth, the calculation results are more reasonable.

  6. The Beryllium-7 Depth Study in Different Land Use

    International Nuclear Information System (INIS)

    Jalal Sharib; Zainudin Othman; Dainee Nor Fardzila Ahmad Tugi; Noor Fadzilah Yusof; Mohd Tarmizi Ishak

    2015-01-01

    The main objective for this study is to evaluate the evolution of 7 Be depth distribution in soil profile at Tasoh Catchment area, Perlis, Malaysia which area has been different land use. The soil samples for this study have been carried out in Timah surroundings by different agricultural land use. Therefore, three different types of soil samples from different land use have been collected by using metal core and have been sectioned into 2 mm increments to a depth of 4 cm. The samples were brought to Radiochemistry and Environment Group Laboratory (RAS), Bangi for further treatment. The samples subsequently oven dried at 45-60 degree Celsius and gently desegregated. The sample is passed through a < 2 mm sieve and packed into geometry plastic container for 7 Be analysis by using gamma spectrometry with a 24-hour count time. From the findings show that the 7 Be soil samples are penetrated with decreases exponentially with depth and is confined within the top few centimeters at most and similar with other works been reported (Blake et al., 2000 and Walling et al., 2008). , the 7 Be from mixed land use also shows more deeper penetration into the soil depth than from two others land use due to a several factors. Therefore, further and detailed discussion for these findings will be described in full paper. (author)

  7. Sub-40 fs, 1060-nm Yb-fiber laser enhances penetration depth in nonlinear optical microscopy of human skin

    Science.gov (United States)

    Balu, Mihaela; Saytashev, Ilyas; Hou, Jue; Dantus, Marcos; Tromberg, Bruce J.

    2015-12-01

    Advancing the practical utility of nonlinear optical microscopy requires continued improvement in imaging depth and contrast. We evaluated second-harmonic generation (SHG) and third-harmonic generation images from ex vivo human skin and showed that a sub-40 fs, 1060-nm Yb-fiber laser can enhance SHG penetration depth by up to 80% compared to a >100 fs, 800 nm Ti:sapphire source. These results demonstrate the potential of fiber-based laser systems to address a key performance limitation related to nonlinear optical microscopy (NLOM) technology while providing a low-barrier-to-access alternative to Ti:sapphire sources that could help accelerate the movement of NLOM into clinical practice.

  8. Magnetic penetration depth and flux dynamics in single-crystal Bi2Sr2CaCu2O8+δ

    International Nuclear Information System (INIS)

    Harshman, D.R.; Kleiman, R.N.; Inui, M.; Espinosa, G.P.; Mitzi, D.B.; Kapitulnik, A.; Pfiz, T.; Williams, D.L.

    1991-01-01

    The muon-spin-relaxation technique has been used to study vortex dynamics in single-phase superconducting single crystals of Bi 2 Sr 2 CaCu 2 O 8+δ (T c ∼90 K). The data indicate motional narrowing of the internal field distribution due to vortex motion (on a time scale comparable to the muon lifetime). A field-dependent lattice transition is also observed at T x ∼30 K, as evidenced by the onset of an asymmetric line shape below T x . Narrowing arising from disordering of the vortices along [001] is also discussed with reference to its effect on the measured penetration depth

  9. Multi-channel ground-penetrating radar to explore spatial variations in thaw depth and moisture content in the active layer of a permafrost site

    Directory of Open Access Journals (Sweden)

    U. Wollschläger

    2010-08-01

    Full Text Available Multi-channel ground-penetrating radar (GPR was applied at a permafrost site on the Tibetan Plateau to investigate the influence of surface properties and soil texture on the late-summer thaw depth and average soil moisture content of the active layer. Measurements were conducted on an approximately 85 × 60 m2 sized area with surface and soil textural properties that ranged from medium to coarse textured bare soil to finer textured, sparsely vegetated areas covered with fine, wind blown sand, and it included the bed of a gravel road. The survey allowed a clear differentiation of the various units. It showed (i a shallow thaw depth and low average soil moisture content below the sand-covered, vegetated area, (ii an intermediate thaw depth and high average soil moisture content along the gravel road, and (iii an intermediate to deep thaw depth and low to intermediate average soil moisture content in the bare soil terrain. From our measurements, we found hypotheses for the permafrost processes at this site leading to the observed late-summer thaw depth and soil moisture conditions. The study clearly indicates the complicated interactions between surface and subsurface state variables and processes in this environment. Multi-channel GPR is an operational technology to efficiently study such a system at scales varying from a few meters to a few kilometers.

  10. Percutaneous penetration studies for risk assessment

    DEFF Research Database (Denmark)

    Sartorelli, Vittorio; Andersen, Helle Raun; Angerer, Jürgen

    2000-01-01

    experiences, literature data and guidelines already in existence. During the meetings of Percutaneous Penetration Subgroup they presented a number of short papers of up to date information on the key issues. The objective was to focus the existing knowledge and the gaps in the knowledge in the field...

  11. Survey to identify depth of penetration of critical incident reporting systems in Austrian healthcare facilities.

    Science.gov (United States)

    Sendlhofer, Gerald; Eder, Harald; Leitgeb, Karina; Gorges, Roland; Jakse, Heidelinde; Raiger, Marianne; Türk, Silvia; Petschnig, Walter; Pregartner, Gudrun; Kamolz, Lars-Peter; Brunner, Gernot

    2018-01-01

    Incident reporting systems or so-called critical incident reporting systems (CIRS) were first recommended for use in health care more than 15 years ago. The uses of these CIRS are highly variable among countries, ranging from being used to report critical incidents, falls, or sentinel events resulting in death. In Austria, CIRS have only been introduced to the health care sector relatively recently. The goal of this work, therefore, was to determine whether and specifically how CIRS are used in Austria. A working group from the Austrian Society for Quality and Safety in Healthcare (ASQS) developed a survey on the topic of CIRS to collect information on penetration of CIRS in general and on how CIRS reports are used to increase patient safety. Three hundred seventy-one health care professionals from 274 health care facilities were contacted via e-mail. Seventy-eight respondents (21.0%) completed the online survey, thereof 66 from hospitals and 12 from other facilities (outpatient clinics, nursing homes). In all, 64.1% of the respondents indicated that CIRS were used in the entire health care facility; 20.6% had not yet introduced CIRS and 15.4% used CIRS only in particular areas. Most often, critical incidents without any harm to patients were reported (76.9%); however, some health care facilities also use their CIRS to report patient falls (16.7%), needle stick injuries (17.9%), technical problems (51.3%), or critical incidents involving health care professionals. CIRS are not yet extensively or homogeneously used in Austria. Inconsistencies exist with respect to which events are reported as well as how they are followed up and reported to health care professionals. Further recommendations for general use are needed to support the dissemination in Austrian health care environments.

  12. The effect of snow/sea ice type on the response of albedo and light penetration depth (e-folding depth to increasing black carbon

    Directory of Open Access Journals (Sweden)

    A. A. Marks

    2014-09-01

    Full Text Available The optical properties of snow/sea ice vary with age and by the processes they were formed, giving characteristic types of snow and sea ice. The response of albedo and light penetration depth (e-folding depth to increasing mass ratio of black carbon is shown to depend on the snow and sea ice type and the thickness of the snow or sea ice. The response of albedo and e-folding depth of three different types of snow (cold polar snow, wind-packed snow and melting snow and three sea ice (multi-year ice, first-year ice and melting sea ice to increasing mass ratio of black carbon is calculated using a coupled atmosphere–snow/sea ice radiative-transfer model (TUV-snow, over the optical wavelengths of 300–800 nm. The snow and sea ice types are effectively defined by a scattering cross-section, density and asymmetry parameter. The relative change in albedo and e-folding depth of each of the three snow and three sea ice types with increasing mass ratio of black carbon is considered relative to a base case of 1 ng g−1 of black carbon. The relative response of each snow and sea ice type is intercompared to examine how different types of snow and sea ice respond relative to each other. The relative change in albedo of a melting snowpack is a factor of four more responsive to additions of black carbon compared to cold polar snow over a black carbon increase from 1 to 50 ng g−1, while the relative change in albedo of a melting sea ice is a factor of two more responsive to additions of black carbon compared to multi-year ice for the same increase in mass ratio of black carbon. The response of e-folding depth is effectively not dependent on snow/sea ice type. The albedo of sea ice is more responsive to increasing mass ratios of black carbon than snow.

  13. Energy absorption buildup factors of human organs and tissues at energies and penetration depths relevant for radiotherapy and diagnostics

    DEFF Research Database (Denmark)

    Manohara, S. R.; Hanagodimath, S. M.; Gerward, Leif

    2011-01-01

    Energy absorption geometric progression (GP) fitting parameters and the corresponding buildup factors have been computed for human organs and tissues, such as adipose tissue, blood (whole), cortical bone, brain (grey/white matter), breast tissue, eye lens, lung tissue, skeletal muscle, ovary......, testis, soft tissue, and soft tissue (4-component), for the photon energy range 0.015-15 MeV and for penetration depths up to 40 mfp (mean free path). The chemical composition of human organs and tissues is seen to influence the energy absorption buildup factors. It is also found that the buildup factor...... of human organs and tissues changes significantly with the change of incident photon energy and effective atomic number, Zeff. These changes are due to the dominance of different photon interaction processes in different energy regions and different chemical compositions of human organs and tissues...

  14. Magnetic penetration depth of YBa2Cu3O(7-delta) thin films determined by the power transmission method

    Science.gov (United States)

    Heinen, Vernon O.; Miranda, Felix A.; Bhasin, Kul B.

    1992-01-01

    A power transmission measurement technique was used to determine the magnetic penetration depth (lambda) of YBa2Cu3O(7-delta) superconducting thin films on LaAlO3 within the 26.5 to 40.0 GHz frequency range, and at temperatures from 20 to 300 K. Values of lambda ranging from 1100 to 2500 A were obtained at low temperatures. The anisotropy of lambda was determined from measurements of c-axis and a-axis oriented films. An estimate of the intrinsic value of lambda of 90 +/- 30 nm was obtained from the dependence of lambda on film thickness. The advantage of this technique is that it allows lambda to be determined nondestructively.

  15. Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays

    Directory of Open Access Journals (Sweden)

    Xile Wei

    2017-11-01

    Full Text Available Multi-coil arrays applied in transcranial magnetic stimulation (TMS are proposed to accurately stimulate brain tissues and modulate neural activities by an induced electric field (EF. Composed of numerous independently driven coils, a multi-coil array has alternative energizing strategies to evoke EFs targeting at different cerebral regions. To improve the locating resolution and the stimulating focality, we need to fully understand the variation properties of induced EFs and the quantitative control method of the spatial arrangement of activating coils, both of which unfortunately are still unclear. In this paper, a comprehensive analysis of EF properties was performed based on multi-coil arrays. Four types of planar multi-coil arrays were used to study the relationship between the spatial distribution of EFs and the structure of stimuli coils. By changing coil-driven strategies in a basic 16-coil array, we find that an EF induced by compactly distributed coils decays faster than that induced by dispersedly distributed coils, but the former has an advantage over the latter in terms of the activated brain volume. Simulation results also indicate that the attenuation rate of an EF induced by the 36-coil dense array is 3 times and 1.5 times greater than those induced by the 9-coil array and the 16-coil array, respectively. The EF evoked by the 36-coil dispense array has the slowest decay rate. This result demonstrates that larger multi-coil arrays, compared to smaller ones, activate deeper brain tissues at the expense of decreased focality. A further study on activating a specific field of a prescribed shape and size was conducted based on EF variation. Accurate target location was achieved with a 64-coil array 18 mm in diameter. A comparison between the figure-8 coil, the planar array, and the cap-formed array was made and demonstrates an improvement of multi-coil configurations in the penetration depth and the focality. These findings suggest

  16. Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays.

    Science.gov (United States)

    Wei, Xile; Li, Yao; Lu, Meili; Wang, Jiang; Yi, Guosheng

    2017-11-14

    Multi-coil arrays applied in transcranial magnetic stimulation (TMS) are proposed to accurately stimulate brain tissues and modulate neural activities by an induced electric field (EF). Composed of numerous independently driven coils, a multi-coil array has alternative energizing strategies to evoke EFs targeting at different cerebral regions. To improve the locating resolution and the stimulating focality, we need to fully understand the variation properties of induced EFs and the quantitative control method of the spatial arrangement of activating coils, both of which unfortunately are still unclear. In this paper, a comprehensive analysis of EF properties was performed based on multi-coil arrays. Four types of planar multi-coil arrays were used to study the relationship between the spatial distribution of EFs and the structure of stimuli coils. By changing coil-driven strategies in a basic 16-coil array, we find that an EF induced by compactly distributed coils decays faster than that induced by dispersedly distributed coils, but the former has an advantage over the latter in terms of the activated brain volume. Simulation results also indicate that the attenuation rate of an EF induced by the 36-coil dense array is 3 times and 1.5 times greater than those induced by the 9-coil array and the 16-coil array, respectively. The EF evoked by the 36-coil dispense array has the slowest decay rate. This result demonstrates that larger multi-coil arrays, compared to smaller ones, activate deeper brain tissues at the expense of decreased focality. A further study on activating a specific field of a prescribed shape and size was conducted based on EF variation. Accurate target location was achieved with a 64-coil array 18 mm in diameter. A comparison between the figure-8 coil, the planar array, and the cap-formed array was made and demonstrates an improvement of multi-coil configurations in the penetration depth and the focality. These findings suggest that there is a

  17. A Study on Factors Affecting Airborne LiDAR Penetration

    Directory of Open Access Journals (Sweden)

    Wei-Chen Hsu

    2015-01-01

    Full Text Available This study uses data from different periods, areas and parameters of airborne LiDAR (light detection and ranging surveys to understand the factors that influence airborne LiDAR penetration rate. A discussion is presented on the relationships between these factors and LiDAR penetration rate. The results show that the flight height above ground level (AGL does not have any relationship with the penetration rate. There are some factors that should have larger influence. For example, the laser is affected by a wet ground surface by reducing the number of return echoes. The field of view (FOV has a slightly negative correlation with the penetration rate, which indicates that the laser incidence angle close to zero should achieve the best penetration. The vegetation cover rate also shows a negative correlation with the penetration rate, thus bare ground and reduced vegetation in the aftermath of a typhoon also cause high penetration rate. More return echoes could be extracted from the full-waveform system, thereby effectively improving the penetration rate. This study shows that full-waveform LiDAR is an effective method for increasing the number of surface reflected echoes. This study suggests avoiding LiDAR survey employment directly following precipitation to prevent laser echo reduction.

  18. Stylet penetration of Cacopsylla pyri; an electrical penetration graph (EPG) study

    NARCIS (Netherlands)

    Civolani, S.; Leis, M.; Grandi, G.; Garzo, E.; Pasqualini, E.; Musacchi, S.; Chicca, M.; Castaldelli, G.; Rossie, M.; Tjallingii, W.F.

    2011-01-01

    Detailed information on plant penetration activities by pear psylla Cacopsylla pyri L. (Hemiptera Psyllidae) is essential to study phytoplasma transmission of “Candidatus Phytoplasma pyri” responsible of pear decline disease (PD) and to trace and evaluate resistant traits in new pear tree selections

  19. Neutron streaming studies along JET shielding penetrations

    Science.gov (United States)

    Stamatelatos, Ion E.; Vasilopoulou, Theodora; Batistoni, Paola; Obryk, Barbara; Popovichev, Sergey; Naish, Jonathan

    2017-09-01

    Neutronic benchmark experiments are carried out at JET aiming to assess the neutronic codes and data used in ITER analysis. Among other activities, experiments are performed in order to validate neutron streaming simulations along long penetrations in the JET shielding configuration. In this work, neutron streaming calculations along the JET personnel entrance maze are presented. Simulations were performed using the MCNP code for Deuterium-Deuterium and Deuterium- Tritium plasma sources. The results of the simulations were compared against experimental data obtained using thermoluminescence detectors and activation foils.

  20. A comparative study on the transdermal penetration effect of gaseous and aqueous plasma reactive species

    Science.gov (United States)

    Liu, Xin; Gan, Lu; Ma, Mingyu; Zhang, Song; Liu, Jingjing; Chen, Hongxiang; Liu, Dawei; Lu, Xinpei

    2018-02-01

    To improve the depth of plasma active species in the skin, it is very important to develop skin disease treatment using plasma. In this article, an air plasma source was used to work directly with the skin of a mouse. A tortuous pathway, hair follicles, electroporation and a microneedle do not aid the transdermal delivery of gaseous plasma active species, therefore these gaseous plasma active species cannot penetrate mouse skin with a thickness of ~0.75 mm. The plasma activated water (PAW) produced by the air plasma source was used to study the transdermal penetration of the aqueous plasma activated species. This aqueous plasma activated species can penetrate the skin through hair follicles, intercellular and transcellular routes. The pH of the PAW did not affect the penetration efficiency of the aqueous plasma active species.

  1. The Spatial Variability of Beryllium-7 Depth Distribution Study

    International Nuclear Information System (INIS)

    Jalal Sharib; Zainudin Othman; Dainee Nor Fardzila Ahmad Tugi; Noor Fadzilah Yusof; Mohd Tarmizi Ishak

    2015-01-01

    The objective of this paper is to study the spatial variability of 7 Be depth evolution in soil profile at two different sampling sites. The soil samples have been collected by using metal core in bare area in Bangi, Selangor and Timah Tasoh, Perlis , Malaysia. Two composite core samples for each sampling sites has been sectioned into 2 mm increments to a depth of 4 cm and oven dried at 45- 60 degree Celsius and gently desegregated. These two composite spatial samples are passed through a < 2 mm sieve and packed into proper geometry plastic container for 7 Be analysis by using gamma spectrometry with a 24-hour count time. From the findings, the 7 Be content in the soil samples from Bangi, Selangor study area is distributed lower depth penetration into the soil profile than Timah Tasoh, Perlis catchment due to many factors such as precipitation (fallout) and others. However, the spatial variability from both samples study area is also decreases exponentially with depth and is confined within the top few centimeters and similar with other works been reported (Blake et al., (2000) and Walling et al.,(2008). Furthermore, a detailed discussion from this study findings will be in full papers. (author)

  2. Ground-Penetrating-Radar Profiles of Interior Alaska Highways: Interpretation of Stratified Fill, Frost Depths, Water Table, and Thaw Settlement over Ice-Rich Permafrost

    Science.gov (United States)

    2016-08-01

    along either massive ice surfaces or within sections of segregated ice. The uninsulated ice surface at Tok in Figure 17B is irregular. All of the...ER D C/ CR RE L TR -1 6- 14 ERDC’s Center-Directed Research Program Ground -Penetrating-Radar Profiles of Interior Alaska Highways...August 2016 Ground -Penetrating-Radar Profiles of Interior Alaska Highways Interpretation of Stratified Fill, Frost Depths, Water Table, and Thaw

  3. Determination of Penetration Depth of 800 keV Electron Beam into Coal Fired Power Plant Flue Gas at in a Electron Beam Machine Flue Gas Treatment System

    International Nuclear Information System (INIS)

    Rany Saptaaji

    2008-01-01

    Penetration depth calculation of 800 keV electron beam into flue gas from coal fired power plan is presented in this paper. Electron Beam for Flue Gas Treatment (EB-FGT) is a dry treatment process using electron beam to simultaneously reduce SO 2 and NO x . Flue gas irradiation produces active radicals and then reaction with SO 2 and NO x produces nitrate acid and sulphate acid. Process vessel is needed in this process as reaction container of flue gas with electron beam. The calculation of electron beam penetration depth into flue gas is used to determine the process vessel dimension. The result of calculation of optimum penetration depth of 800 keV electron beam into flue gas is 188.67 cm. (author)

  4. Long range surface plasmon resonance with ultra-high penetration depth for self-referenced sensing and ultra-low detection limit using diverging beam approach

    Energy Technology Data Exchange (ETDEWEB)

    Isaacs, Sivan, E-mail: sivan.isaacs@gmail.com; Abdulhalim, Ibrahim [Department of Electro-Optical Engineering and TheIlse Katz Institute for Nanoscale Science and Technology, Ben Gurion University of the Negev, Beer Sheva 84105 (Israel); NEW CREATE Programme, School of Materials Science and Engineering, 1 CREATE Way, Research Wing, #02-06/08, Singapore 138602 (Singapore)

    2015-05-11

    Using an insulator-metal-insulator structure with dielectric having refractive index (RI) larger than the analyte, long range surface plasmon (SP) resonance exhibiting ultra-high penetration depth is demonstrated for sensing applications of large bioentities at wavelengths in the visible range. Based on the diverging beam approach in Kretschmann-Raether configuration, one of the SP resonances is shown to shift in response to changes in the analyte RI while the other is fixed; thus, it can be used as a built in reference. The combination of the high sensitivity, high penetration depth and self-reference using the diverging beam approach in which a dark line is detected of the high sensitivity, high penetration depth, self-reference, and the diverging beam approach in which a dark line is detected using large number of camera pixels with a smart algorithm for sub-pixel resolution, a sensor with ultra-low detection limit is demonstrated suitable for large bioentities.

  5. Penetration of ASM 981 in canine skin: a comparative study.

    Science.gov (United States)

    Gutzwiller, Meret E Ricklin; Reist, Martin; Persohn, Elke; Peel, John E; Roosje, Petra J

    2006-01-01

    ASM 981 has been developed for topical treatment of inflammatory skin diseases. It specifically inhibits the production and release of pro-inflammatory cytokines. We measured the skin penetration of ASM 981 in canine skin and compared penetration in living and frozen skin. To make penetration of ASM 981 visible in dog skin, tritium labelled ASM 981 was applied to a living dog and to defrosted skin of the same dog. Using qualitative autoradiography the radioactive molecules were detected in the lumen of the hair follicles until the infundibulum, around the superficial parts of the hair follicles and into a depth of the dermis of 200 to 500 microm. Activity could not be found in deeper parts of the hair follicles, the dermis or in the sebaceous glands. Penetration of ASM 981 is low in canine skin and is only equally spread in the upper third of the dermis 24 hours after application. Penetration in frozen skin takes even longer than in living canine skin but shows the same distribution.

  6. Fluorescent Penetrant INSPECTION—CLEANING Study Update

    Science.gov (United States)

    Eisenmann, D.; Brasche, L.

    2009-03-01

    Fluorescent penetrant inspection (FPI) is widely used in the aviation industry and other industries for surface-breaking crack detection. As with all inspection methods, adherence to the process parameters is critical to the successful detection of defects. There is variety of lubricants and surface coatings used in the aviation industry which must be removed prior to FPI. Before the FPI process begins, components are cleaned using a variety of cleaning methods which are selected based on the alloy and the soil types which must be removed. It is also important that the cleaning process not adversely affect the FPI process. From the first three phases of this project it has been found that a hot water rinse can aid in the detection process when using this nondestructive method.

  7. Comparison of pellet acceleration model results to experimentally observed penetration depths

    Energy Technology Data Exchange (ETDEWEB)

    Szepesi, T., E-mail: szepesi.tamas@gmail.co [KFKI - Research Institute for Particle and Nuclear Physics, EURATOM Association, MTA KFKI-RMKI, P.O. Box 49, H-1525 Budapest-114 (Hungary); Kalvin, S.; Kocsis, G. [KFKI - Research Institute for Particle and Nuclear Physics, EURATOM Association, MTA KFKI-RMKI, P.O. Box 49, H-1525 Budapest-114 (Hungary); Lang, P.T. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstr. 2, 85748 Garching (Germany); Senichenkov, I. [Saint Petersburg State Polytechnical University, Polytehnicheskaya 29, 195251 St. Petersburg (Russian Federation)

    2009-06-15

    Cryogenic hydrogen isotope fuelling pellets were observed to undergo strong radial acceleration in the confined plasma. The reason for pellet acceleration is believed to originate from drift effects: the ionised part of pellet cloud is affected by the grad-B drift, therefore, the cloud becomes polarised. The E x B drift then deforms the pellet cloud so that it can no longer follow the original flux bundle - this results in a less efficient shielding on the pellet's HFS region, where the subsequently enhanced ablation pushes the pellet towards LFS, like a rocket. In order to study this effect, a simple and a comprehensive ablation model was developed. Results from both models show quantitatively acceptable agreement with ASDEX-Upgrade experiments concerning trajectory curvature, corresponding to radial acceleration in the range of 10{sup 4}-10{sup 7} m/s{sup 2}.

  8. A study of the penetration of projectiles into marine sediments

    International Nuclear Information System (INIS)

    Boisson, J.Y.

    1985-01-01

    The work described in this document consists of three main parts: - Application, after having reviewed calculation methods and known codes, of a dynamic plasticity model based on the upper bound-method (with dissipated energy calculations by plastic deformations). The soil model used for this calculation is the Cambridge Clay Model. - Carrying out a programme of tests with instrumented small scale penetrators in centrifuge on a consolidated clay-target. The trials are done under 50 g, with projectiles, fired with an airgun at high impact velocity (50 m/s). The penetrators' instrumentation consists of either measuring acceleration, or tip force with strain gauges. - The mounting of a small instrumented penetrator for shallow water depth experimentations, with an accelerometer, and a local cell for tip resistance. A rapid electronic data acquisition system has been developed for these experimentations. The preliminary tests are done in a large tank filled with clay. The geotechnical characteristics of the clay are perfectly controlled. The tests performed under these conditions have shown the following observations: the rapid electronic data acquisition system works perfectly and could be used as a basic component for a deep water instrumentated penetrator; the results, obtained in these particular test conditions, are in a perfect agreement with the predictions of the model developed in the frame of this contract

  9. Mobile Variable Depth Sampling System Design Study

    International Nuclear Information System (INIS)

    BOGER, R.M.

    2000-01-01

    A design study is presented for a mobile, variable depth sampling system (MVDSS) that will support the treatment and immobilization of Hanford LAW and HLW. The sampler can be deployed in a 4-inch tank riser and has a design that is based on requirements identified in the Level 2 Specification (latest revision). The waste feed sequence for the MVDSS is based on Phase 1, Case 3S6 waste feed sequence. Technical information is also presented that supports the design study

  10. Mobile Variable Depth Sampling System Design Study

    Energy Technology Data Exchange (ETDEWEB)

    BOGER, R.M.

    2000-08-25

    A design study is presented for a mobile, variable depth sampling system (MVDSS) that will support the treatment and immobilization of Hanford LAW and HLW. The sampler can be deployed in a 4-inch tank riser and has a design that is based on requirements identified in the Level 2 Specification (latest revision). The waste feed sequence for the MVDSS is based on Phase 1, Case 3S6 waste feed sequence. Technical information is also presented that supports the design study.

  11. Penetration Depth and Defect Image Contrast Formation in Grazing-Incidence X-ray Topography of 4H-SiC Wafers

    Science.gov (United States)

    Yang, Yu; Guo, Jianqiu; Goue, Ouloide Yannick; Kim, Jun Gyu; Raghothamachar, Balaji; Dudley, Michael; Chung, Gill; Sanchez, Edward; Manning, Ian

    2018-02-01

    Synchrotron x-ray topography in grazing-incidence geometry is useful for discerning defects at different depths below the crystal surface, particularly for 4H-SiC epitaxial wafers. However, the penetration depths measured from x-ray topographs are much larger than theoretical values. To interpret this discrepancy, we have simulated the topographic contrast of dislocations based on two of the most basic contrast formation mechanisms, viz. orientation and kinematical contrast. Orientation contrast considers merely displacement fields associated with dislocations, while kinematical contrast considers also diffraction volume, defined as the effective misorientation around dislocations and the rocking curve width for given diffraction vector. Ray-tracing simulation was carried out to visualize dislocation contrast for both models, taking into account photoelectric absorption of the x-ray beam inside the crystal. The results show that orientation contrast plays the key role in determining both the contrast and x-ray penetration depth for different types of dislocation.

  12. Calculation of optical properties of dental composites as a basis for determining color impression and penetration depth of laser light

    Science.gov (United States)

    Weniger, Kirsten K.; Muller, Gerhard J.

    2005-03-01

    In order to achieve esthetic dental restorations, there should be no visible difference between restorative material and treated teeth. This requires a match of the optical properties of both restorative material and natural teeth. These optical properties are determined by absorption and scattering of light emerging not only on the surface but also inside the material. Investigating different dental composites in several shades, a method has been developed to calculate the optical parameters absorption coefficient μa, scattering coefficient μs, anisotropy factor g and reduced scattering coefficient μs'. The method includes sample preparation and measurements of transmittance and reflectance in an integrating sphere spectrometer, followed by inverse Monte Carlo simulations. Determination of optical properties is more precise and comprehensive than with the previously used Kubelka Munk theory because scattering can be looked at separated into pure scattering with the scattering coefficient μs and its direction with the anisotropy factor g. Moreover the use of the inverse Monte Carlo simulation not only minimizes systematic errors and considers the scattering phase function, but also takes into account the measuring geometry. The compilation of a data pool of optical parameters now enables the application of further calculation models as a basis for optimization of the composition of new materials. For example, a prediction of the general color impression for multiple layers can be carried out as well as the calculation of the wavelength dependent penetration depths of light with regard to photo polymerization. Further applications are possible in the area of laser ablation.

  13. UO2/magnetite concrete interaction and penetration study

    International Nuclear Information System (INIS)

    Farhadieh, R.; Purviance, R.; Carlson, N.

    1983-01-01

    The concrete structure represents a line of defense in safety assessment of containment integrity and possible minimization of radiological releases following a reactor accident. The penetration study of hot UO 2 particles into limestone concrete and basalt concrete highlighted some major differences between the two concretes. These included penetration rate, melting and dissolution phenomena, released gases, pressurization of the UO 2 chamber, and characteristics of post-test concrete. The present study focuses on the phenomena associated with core debris interaction with and penetration into magnetite type concrete. The real material experiment was carried out with UO 2 particles and magnetite concrete in a test apparatus similar to the one utilized in the UO 2 /limestone experiment

  14. Measurement of the London penetration depths in YBa2Cu3Ox by means of muon spin rotation (μ SR) experiments

    International Nuclear Information System (INIS)

    Pumpin, B.; Keller, H.; Kundig, W.; Odermatt, W.; Savic, I.M.; Schneider, J.W.; Simmler, H.; Zimmermann, P.

    1989-01-01

    The authors report on experiments conducted to get accurate values of the London penetration depths in YBa 2 Cu 3 O x , μSR measurements were performed on a high quality, sintered sample and a c-axis-oriented polycrystal. For the sintered sample the temperature dependence of the effective penetration depthλ eff is well described by the two-fluid model, withλ eff (0) = 155(10) nm. This behavior ofλ eff (T) is consistent with conventional s-wave pairing. The anisotropy ratioλ c /λ ab ≅5(1) was determined from measurements on the polycrystal. These results were used to calculateλ ab (0) = 130(10) nm andλ c (0)≅ 500-800 nm

  15. Measurements of the London penetration depths in YBa sub 2 Cu sub 3 O sub x by means of muon spin rotation (. mu. SR) experiments

    Energy Technology Data Exchange (ETDEWEB)

    Puempin, B.; Keller, H.; Kuendig, W.; Odermatt, W.; Savic, I.M.; Schneider, J.W.; Simmler, H.; Zimmermann, P. (Physik-Inst., Univ. Zuerich (Switzerland)); Bednorz, J.G.; Maeno, Y.; Mueller, K.A.; Rossel, C. (IBM Research Div., Zuerich Research Lab., Rueschlikon (Switzerland)); Kaldis, E.; Rusiecki, S. (Lab. fuer Festkoerperphysik, ETH Zuerich (Switzerland)); Assmus, W.; Kowalewski, J. (Physikalisches Inst., Univ. Frankfurt (Germany, F.R.))

    1989-12-01

    To get accurate values of the London penetration depths in YBa{sub 2}Cu{sub 3}O{sub x}, {mu}SR measurements were performed on a high quality, sintered sample and a c-axis-oriented polycrystal. For the sintered sample the temperature dependence of the effective penetration depth {lambda}{sub eff} is well described by the two-fluid model, with {lambda}{sub eff}(0) = 155(10) nm. This behavior of {lambda}{sub eff}(T) is consistent with conventional s-wave pairing. The anisotropy ratio {lambda}{sub c}/{lambda}{sub ab} {approx equal} 5(1) was determined from measurements on the polycrystal. These results were used to calculate {lambda}{sub ab}(0) = 130(10) nm and {lambda}{sub c}(0) {approx equal} 500-800 nm. (orig.).

  16. Measurement and modeling of the low-temperature penetration-depth anomaly in high-quality MgB{sub 2} thin films

    Energy Technology Data Exchange (ETDEWEB)

    Agassi, Y.D. [Naval Surface Warfare Center, Carderock Division, Bethesda, MD 20817 (United States); Oates, D.E., E-mail: OATES@LL.MIT.EDU [MIT-Lincoln Laboratory, Lexington, MA 02420 (United States); Moeckly, B.H. [STI, Inc. Santa Barbara, CA 93111 (United States)

    2012-10-15

    Based on our measurements of intermodulation distortion in MgB{sub 2}, we have previously proposed that the {pi} energy-gap in MgB{sub 2} entails six nodal lines [Y.D. Agassi, D.E. Oates, and B.H. Moeckly, Phys. Rev. B 80 (2009) 174522]. Here we report high-precision measurements in MgB{sub 2} stripline resonators that show an increase of the penetration depth as the temperature is decreased below 5 K. This increase is consistent with the Script-Small-L = 6 symmetry of the {pi} energy gap that we have proposed. We interpret the increase as a manifestation of Andreev surface-attached states that are associated with the nodal lines of the {pi} energy gap. Penetration-depth calculations are in good agreement with our data. To reconcile the present interpretation with existing literature, we review other penetration-depth data, magnetic-impurity and tunneling experiments, and data on the paramagnetic Meissner effect. We conclude that these data do not rule out the interpretation of our experimental data based on a nodal {pi} energy gap.

  17. A Novel Penetration System for in situ Astrobiological Studies

    Directory of Open Access Journals (Sweden)

    Yang Gao

    2005-12-01

    Full Text Available Due to ultraviolet flux in the surface layers of most solar bodies, future astrobiological research is increasingly seeking to conduct subsurface penetration and drilling to detect chemical signature for extant or extinct life. To address this issue, we present a micro-penetrator concept (mass < 10 kg that is suited for extraterrestrial planetary deployment and in situ investigation of chemical and physical properties. The instrumentation in this concept is a bio-inspired drill to access material beneath sterile surface layer for biomarker detection. The proposed drill represents a novel concept of two-valve-reciprocating motion, inspired by the working mechanism of wood wasp ovipositors. It is lightweight (0.5 kg, driven at low power (3 W, and able to drill deep (1-2 m. Tests have shown that the reciprocating drill is feasible and has potential of improving drill efficiency without using any external force. The overall penetration system provides a small, light and energy efficient solution to in situ astrobiological studies, which is crucial for space engineering. Such a micro-penetrator can be used for exploration of terrestrial-type planets or other small bodies of the solar system with the minimum of modifications.

  18. A Novel Penetration System for in situ Astrobiological Studies

    Directory of Open Access Journals (Sweden)

    Yang Gao

    2008-11-01

    Full Text Available Due to ultraviolet flux in the surface layers of most solar bodies, future astrobiological research is increasingly seeking to conduct subsurface penetration and drilling to detect chemical signature for extant or extinct life. To address this issue, we present a micro-penetrator concept (mass < 10 kg that is suited for extraterrestrial planetary deployment and in situ investigation of chemical and physical properties. The instrumentation in this concept is a bio-inspired drill to access material beneath sterile surface layer for biomarker detection. The proposed drill represents a novel concept of two-valve-reciprocating motion, inspired by the working mechanism of wood wasp ovipositors. It is lightweight (0.5 kg, driven at low power (3 W, and able to drill deep (1-2 m. Tests have shown that the reciprocating drill is feasible and has potential of improving drill efficiency without using any external force. The overall penetration system provides a small, light and energy efficient solution to in situ astrobiological studies, which is crucial for space engineering. Such a micro-penetrator can be used for exploration of terrestrial-type planets or other small bodies of the solar system with the minimum of modifications.

  19. Topical administration of Tetrasodium-Mesotetraphenyl-Porphinesulfonate (TPPS): correlations between drug penetration and depth of necrosis in skin of nude mice following red light irradiation

    International Nuclear Information System (INIS)

    Marchesini, R.; Melloni, E.; Fava, G.

    1987-01-01

    The main side effect in photodynamic therapy is photosensitization of the patient's skin following systemic administration of the photosensitizing agent. In the case of superficial lesions, this problem can be avoided by topically applying the drug: in this way a local treatment can be performed. The photosensitizing properties of a 2% solution of TPPS (Tetrasodium-Tetraphenylpophinesulfonate) in a vehicle containing a penetration enhancer, Azone, on skin of nude mice has been tested. An aliquot of 0.1 ml/cm 2 of the solution was painted on the skin overlying an s.c. implanted NMU-1 tumor. Subsequently, animals were sacrificed at different times after applications. Fluorescence microscopy revealed that TPPS penetration depth was related to time elapsed after application and to painting modalities. Solution penetration was enhanced by wiping with ether immediately before painting. Irradiation at 80 mW/cm 2 for 20 min with a dye laser emitting at 640 nm, 4 h after TPPS applications, produced necrosis of the upper skin layers, up to 0.2 mm in depth. These findings suggest that topical TPPS administration, followed by laser irradiation, may be a suitable treatment modality for skin lesions involving epithelial layers, even though several aspects of this methodology need further investigation

  20. Study into penetration speed during laser cutting of brain tissues.

    Science.gov (United States)

    Yilbas, Z; Sami, M; Patiroglu, T

    1998-01-01

    The applications of CO2 continuous-wave lasers in neurosurgery have become important in recent years. Theoretical considerations of laser applicability in medicine are subsequently confirmed experimentally. To obtain precision operation in the laser cutting process, further theoretical developments and experimental studies need to be conducted. Consequently, in the present study, the heat transfer mechanism taking place during laser-tissue interaction is introduced using Fourier theory. The results obtained from the theoretical model are compared with the experimental results. In connection with this, an experiment is designed to measure the penetration speed during the laser cutting process. The measurement is carried out using an optical method. It is found that both results for the penetration speed obtained from the theory and experiment are in a good agreement.

  1. Influence of structural disorder on low-temperature behavior of penetration depth in electron-doped high-TC thin films

    International Nuclear Information System (INIS)

    Lanfredi, A.J.C.; Sergeenkov, S.; Araujo-Moreira, F.M.

    2006-01-01

    To probe the influence of structural disorder on low-temperature behavior of magnetic penetration depth, λ(T), in electron-doped high-T C superconductors, a comparative study of high-quality Pr 1.85 Ce 0.15 CuO 4 (PCCO) and Sm 1.85 Ce 0.15 CuO 4 (SCCO) thin films is presented. The λ(T) profiles are extracted from conductance-voltage data using a highly-sensitive home-made mutual-inductance technique. The obtained results confirm a d-wave pairing mechanism in both samples (with nodal gap parameter Δ 0 /k B T C =2.0 and 2.1 for PCCO and SCCO films, respectively), substantially modified by impurity scattering (which is more noticeable in less homogeneous SCCO films) at the lowest temperatures. More precisely, Δλ(T)=λ(T)-λ(0) is found to follow the Goldenfeld-Hirschfeld interpolation formulae Δλ(T)/λ(0)=AT 2 /(T+T 0 ) with T 0 =ln(2)k B Γ 1/2 Δ 0 1/2 being the crossover temperature which demarcates pure and impure scattering processes (T 0 /T C =0.13 and 0.26 for PCCO and SCCO films, respectively). The value of the extracted impurity scattering rate Γ correlates with the quality of our samples and is found to be much higher in less homogeneous films with lower T C

  2. Assessing the Penetrating Abilities of Experimental Preparation with Dental Infiltrant Features Using Optical Microscope: Preliminary Study.

    Science.gov (United States)

    Skucha-Nowak, Małgorzata; Machorowska-Pieniążek, Agnieszka; Tanasiewicz, Marta

    2016-01-01

    The aim of the infiltration technique is to penetrate demineralized enamel with a low viscosity resin. Icon® (DMG) is the first ever and so far the only dental infiltrant. Bacteriostaticity is one of the properties that should be inherent in dental infiltrants, but Icon lacks this feature. The aim of the preliminary study was to properly choose a dye which would allow us to assess the penetrating abilities of our own, experimental preparation with features of a dental infiltrant with bacteriostatic properties and to compare using an optical microscope the depth of infiltration of the designed experimental preparation with the infiltrant available on the market. The preparation is supposed to infiltrate decalcified human enamel and be assessed with an optical microscope. Eosin, neutral fuchsine and methylene blue were added to experimental preparation with dental infiltrant features and to Icon® (DMG) in order to assess the depth of penetration of the experimental solution into the decalcified layers of enamel. The experimental solution mixes well with eosin, neutral fuchsine, and methylene blue. During the preliminary study, the authors concluded that the experimental solution mixes well with methylene blue, neutral fuchsine, and eosin. An addition of eosin to a preparation which infiltrates inner, demineralized enamel layers, facilitates the assessment of such a preparation with an optical microscope. A designed experimental solution with the main ingredients, i.e., 2-hydroxyethyl methacrylate (HEMA) and tetraethylene glycol dimethacrylate (TEGDMA) with a ratio of 75% to 25% penetrates the demineralized (decalcified) inner parts of the enamel and polymerizes when exposed to light. In order to assess the infiltration of the experimental solution into the demineralized enamel layers, it is required to improve the measurement techniques that utilize optical microscopy.

  3. A Study to Increase Weld Penetration in P91 Steel During TIG Welding by using Activating Fluxes

    Science.gov (United States)

    Singh, Akhilesh Kumar; Kumar, Mayank; Dey, Vidyut; Naresh Rai, Ram

    2017-08-01

    Activated Flux TIG (ATIG) welding is a unique joining process, invented at Paton Institute of electric welding in 1960. ATIG welding process is also known as flux zoned TIG (FZTIG). In this process, a thin layer of activating flux is applied along the line on the surface of the material where the welding is to be carries out. The ATIG process aids to increase the weld penetration in thick materials. Activating fluxes used in the literature show the use of oxides like TiO2, SiO2, Cr2O3, ZnO, CaO, Fe2O3, and MnO2 during welding of steels. In the present study, ATIG was carried out on P-91 steel. Though, Tungsten Inert Gas welding gives excellent quality welds, but the penetration obtained in such welding is still demanding. P91 steel which is ferritic steel is used in high temperature applications. As this steel is, generally, used in thick sections, fabrication of such structures with TIG welding is limited, due to its low depth of penetration. To increase the depth of penetration in P91while welding with ATIG, the role of various oxides were investigated. Apart from the oxides mentioned above, in the present study the role of B2O3, V2O5 and MgO, during ATIG welding of P91 was investigated. It was seen that, compared to TIG welding, there was phenomenal increase in weld penetration during ATIG welding. Amongst all the oxides used in this study, maximum penetration was achieved in case of B2O3. The measurements of weld penetration, bead width and heat affected zone of the weldings were carried out using an image analysis technique.

  4. The study of penetration of energetic ions in botanic samples with transmission measurements

    International Nuclear Information System (INIS)

    Wang, Y.G.; Chen, Q.Z.; Xue, J.M.; Du, G.H.; Qin, H.L; Zhang, W.M.; Yan, S.; Zhao, W.J.

    2006-01-01

    Botanic samples (onion endocuticles, kidney bean slices) were exposed to energetic ions. By recording transmission spectra, we studied the energy loss in such samples. Individual protrusion-like damage produced in highly oriented pyrolytic graphite (HOPG) substrate allowed us to analyze the mass density of the samples by scanning tunneling microscope (STM). The experimental results showed that the botanic sample is inhomogeneous in mass density, some incident ions lose only a small part of their energy after being stopped by a layer of botanic sample. Additionally, about 10 -7 of the incident ions with energy of tens of keV can penetrate through the botanic slice with a thickness of 50 μm. The dynamic change of the transmission spectrum of MeV heavy ions through a layer of botanic slice showed that the penetration ability of the incident ions increases with increasing ion fluence. These experimental results indicate that the inhomogeneousity of mass density of botanic samples and irradiation damage are the main reasons of the ultra-depth penetration of low-energy ions in such kind of botanic samples

  5. Effects of relative plate motion on the deep structure and penetration depth of slabs below the Izu-Bonin and Mariana island arcs

    NARCIS (Netherlands)

    Hilst, R.D. van der; Seno, Tetsuzo

    1993-01-01

    An increasing number of seismological studies indicate that slabs of subducted lithosphere penetrate the Earth's lower mantle below some island arcs but are deflected, or, rather, laid down, in the transition zone below others. Recent numerical simulations of mantle flow also advocate a hybrid form

  6. Improving Focal Depth Estimates: Studies of Depth Phase Detection at Regional Distances

    Science.gov (United States)

    Stroujkova, A.; Reiter, D. T.; Shumway, R. H.

    2006-12-01

    The accurate estimation of the depth of small, regionally recorded events continues to be an important and difficult explosion monitoring research problem. Depth phases (free surface reflections) are the primary tool that seismologists use to constrain the depth of a seismic event. When depth phases from an event are detected, an accurate source depth is easily found by using the delay times of the depth phases relative to the P wave and a velocity profile near the source. Cepstral techniques, including cepstral F-statistics, represent a class of methods designed for the depth-phase detection and identification; however, they offer only a moderate level of success at epicentral distances less than 15°. This is due to complexities in the Pn coda, which can lead to numerous false detections in addition to the true phase detection. Therefore, cepstral methods cannot be used independently to reliably identify depth phases. Other evidence, such as apparent velocities, amplitudes and frequency content, must be used to confirm whether the phase is truly a depth phase. In this study we used a variety of array methods to estimate apparent phase velocities and arrival azimuths, including beam-forming, semblance analysis, MUltiple SIgnal Classification (MUSIC) (e.g., Schmidt, 1979), and cross-correlation (e.g., Cansi, 1995; Tibuleac and Herrin, 1997). To facilitate the processing and comparison of results, we developed a MATLAB-based processing tool, which allows application of all of these techniques (i.e., augmented cepstral processing) in a single environment. The main objective of this research was to combine the results of three focal-depth estimation techniques and their associated standard errors into a statistically valid unified depth estimate. The three techniques include: 1. Direct focal depth estimate from the depth-phase arrival times picked via augmented cepstral processing. 2. Hypocenter location from direct and surface-reflected arrivals observed on sparse

  7. BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES

    Energy Technology Data Exchange (ETDEWEB)

    Farquar, G; Leif, R

    2009-07-15

    Biocompatible polymers with hydrolyzable chemical bonds have been used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres were produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

  8. London penetration depth measurements in Ba (Fe1-xTx)2As2(T=Co,Ni,Ru,Rh,Pd,Pt,Co+Cu) superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, Ryan T. [Iowa State Univ., Ames, IA (United States)

    2011-01-01

    The London penetration depth has been measured in various doping levels of single crystals of Ba(Fe1-xTx)2As2 (T=Co,Ni,Ru,Rh,Pd,Pt,Co+Cu) superconductors by utilizing a tunnel diode resonator (TDR) apparatus. All in-plane penetration depth measurements exhibit a power law temperature dependence of the form Δλab(T) = CTn, indicating the existence of low-temperature, normal state quasiparticles all the way down to the lowest measured temperature, which was typically 500 mK. Several different doping concentrations from the Ba(Fe1-xTx)2As2 (T=Co,Ni) systems have been measured and the doping dependence of the power law exponent, n, is compared to results from measurements of thermal conductivity and specific heat. In addition, a novel method has been developed to allow for the measurement of the zero temperature value of the in-plane penetration depth, λab(0), by using TDR frequency shifts. By using this technique, the doping dependence of λab(0) has been measured in the Ba(Fe1-xCox)2As2 series, which has allowed also for the construction of the doping-dependent superfluid phase stiffness, ρs(T) = [λ(0)/λ(T)]2. By studying the effects of disorder on these superconductors using heavy ion irradiation, it has been determined that the observed power law temperature dependence likely arises from pair-breaking impurity scattering contributions, which is consistent with the proposed s±-wave symmetry of the superconducting gap in the dirty scattering limit. This hypothesis is supported by the measurement of an exponential temperature dependence of the penetration depth in the intrinsically clean LiFeAs, indicative of a nodeless superconducting gap.

  9. Muon-Spin Rotation Measurements of the Magnetic Field Dependence of the Vortex-Core Radius and Magnetic Penetration Depth in NbSe2

    International Nuclear Information System (INIS)

    Sonier, J.E.; Kiefl, R.F.; Brewer, J.H.; Chakhalian, J.; Dunsiger, S.R.; MacFarlane, W.A.; Miller, R.I.; Wong, A.; Luke, G.M.; Brill, J.W.

    1997-01-01

    Muon-spin rotation spectroscopy (μSR) has been used to measure the internal magnetic field distribution in NbSe 2 for H c1 c2 . The deduced profiles of the supercurrent density J s indicate that the vortex-core radius ρ 0 in the bulk decreases sharply with increasing magnetic field. This effect, which is attributed to increased vortex-vortex interactions, does not agree with the dirty-limit microscopic theory. A simple phenomenological equation in which ρ 0 depends on the intervortex spacing is used to model this behavior. In addition, we find for the first time that the in-plane magnetic penetration depth λ ab increases linearly with H in the vortex state of a conventional superconductor. copyright 1997 The American Physical Society

  10. A Novel Method for Measurements of the Penetration Depth of MgB2 Superconductor Films by Using Sapphire Resonators with Short-Circuited Parallel Plates

    International Nuclear Information System (INIS)

    Jung, Ho Sang; Lee, J. H.; Cho, Y. H.; Lee, Sang Young; Seong, W. K.; Lee, N. H.; Kang, W. N.

    2009-01-01

    We introduce a measurement method that enables to measure the penetration depth(λ) of superconductor films by using a short-ended parallel plate sapphire resonator. Variations in the (λof MgB 2 films could be measured down to the lowest temperature using a sapphire resonator with a YBa 2 Cu 3 O 7-x film at the bottom. A model equation of λλ 0 [1-(T/T c ) τ ] -1/2 for MgB 2 films appeared to describe the observed variations of the resonant frequency of the sapphire resonator with temperature, with λ 0 , τ and T c used as the fitting parameters.

  11. Experimental and numerical studies on penetration of shaped charge into concrete and pebble layered targets

    Directory of Open Access Journals (Sweden)

    C Wang

    2017-09-01

    Full Text Available Experiments on penetrating into concrete and pebble layered targets were performed by shaped charge with different cone angles, liner wall thicknesses, length to diameter ratios and charge diameters at different standoffs. Based on the experimental data, the influence of shaped charge’s structural parameters on crater diameter, hole diameter, crater depth and penetration depth was analyzed in detail. Meanwhile, formation and penetration processes of all shaped charges were simulated by AUTODYN software for investigating the more intrinsic mechanisms, in which the numerical models are the same as those set up in the experiments. The results obtained in this paper indicate that there are obvious differences between jetting projectile charge (JPC and explosively formed projectile (EFP in penetrating into multi-layer targets. For the same charge diameter, the values of hole diameter formed by EFP were much larger than JPC. However, for the same standoff, the penetration depth caused by JCP were larger than EFP. The interfacial effect exists in the penetration progress of JPC.

  12. Ground-penetrating radar study of the Rahivere peat bog, eastern Estonia

    Directory of Open Access Journals (Sweden)

    Jüri Plado

    2011-03-01

    Full Text Available The current case study presents results of the ground-penetrating radar (GPR profiling at one of the Saadjärve drumlin field interstitial troughs, the Rahivere bog, eastern Estonia. The study was conducted in order to identify the bog morphology, and the thickness and geometry of the peat body. The method was also used to describe the applicability of GPR in the evaluation of the peat deposit reserve as the Rahivere bog belongs among the officially registered peat reserves. Fourteen GPR profiles, ~ 100 m apart and oriented perpendicular to the long axis of the depression, covering the bog and its surrounding areas, were acquired. In order to verify the radar image interpretation as well as to evaluate the velocity of electromagnetic waves in peat, a common source configuration was utilized and thirteen boreholes were drilled on the GPR profiles. A mean value of 0.036 m ns–1 corresponding to relative dielectric permittivity of 69.7 was used for the time–depth conversion. Radar images reveal major reflection from the peat–soil interface up to a depth of about 4 m, whereas drillings showed a maximum thickness of 4.5 m of peat. Minor reflections appear from the upper peat and mineral soil. According to the borehole data, undecomposed peat is underlain by decomposed one, but identifying them by GPR is complicated. Mineral soil consists of glaciolimnic silty sand in the peripheral areas of the trough, overlain by limnic clay in the central part. The calculated peat volumes (1 200 000 m3 were found to exceed the earlier estimation (979 000 m3 that was based solely on drilling data. Ground-penetrating radar, as a method that allows mapping horizontal continuity of the sub-peat interface in a non-destructive way, was found to provide detailed information for evaluating peat depth and extent.

  13. A study on depth-scaling of plastic phantom in electron beam dosimetry

    International Nuclear Information System (INIS)

    Kojima, T.; Saitoh, H.; Kawachi, T.; Katayose, T.; Myojyoyama, A.

    2005-01-01

    In recommendations of several standard dosimetry, water is defined as the reference medium, however, the water substitute plastic phantoms are highly discouraged. Nevertheless, in the case of accurate chamber positioning in water is not possible, or no waterproof chamber is available, their use is permitted at beam qualities R 50 2 (E 0 pl obtained from a ratio of electron average penetration depth; z av , half value depth ratio; (R 50 ) w,m from Monte Carlo dose calculation and that from measurements, are compared each other. As a result, there are slight differences in depth-scaling factor between obtained from simulation results and from measurements. These results indicate that c pl has to be studied more detail for the sake of precise electron dosimetry in plastic phantoms. (author)

  14. BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES

    Energy Technology Data Exchange (ETDEWEB)

    farquar, G; Leif, R

    2008-09-12

    Biocompatible polymers with hydrolyzable chemical bonds are being used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres are being produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. The advantages and disadvantages of each method will be presented and discussed in greater detail along with fluorescent and charge properties of the aerosols. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

  15. The first critical field, Hc1perpendicularto, and the penetration depth in dirty superconducting S/N multilayers

    International Nuclear Information System (INIS)

    Golubov, A.A.; Krasnov, V.M.

    1992-01-01

    The proximity effect in dirty S/N multilayers is studied theoretically. The structure of the Abrikosov vortex and the first critical field, H c1 perpendicular to , in a perpendicular magnetic field is investigated. Our approach is based on solving Ginzburg-Landau and Usadel equations with boundary conditions applicable to real structures. It was shown that for highly conducting N-layers there exists a positive curvature on H c1 (T) dependences. (orig.)

  16. Adaptive Neuro-Fuzzy Inference System (ANFIS)-Based Models for Predicting the Weld Bead Width and Depth of Penetration from the Infrared Thermal Image of the Weld Pool

    Science.gov (United States)

    Subashini, L.; Vasudevan, M.

    2012-02-01

    Type 316 LN stainless steel is the major structural material used in the construction of nuclear reactors. Activated flux tungsten inert gas (A-TIG) welding has been developed to increase the depth of penetration because the depth of penetration achievable in single-pass TIG welding is limited. Real-time monitoring and control of weld processes is gaining importance because of the requirement of remoter welding process technologies. Hence, it is essential to develop computational methodologies based on an adaptive neuro fuzzy inference system (ANFIS) or artificial neural network (ANN) for predicting and controlling the depth of penetration and weld bead width during A-TIG welding of type 316 LN stainless steel. In the current work, A-TIG welding experiments have been carried out on 6-mm-thick plates of 316 LN stainless steel by varying the welding current. During welding, infrared (IR) thermal images of the weld pool have been acquired in real time, and the features have been extracted from the IR thermal images of the weld pool. The welding current values, along with the extracted features such as length, width of the hot spot, thermal area determined from the Gaussian fit, and thermal bead width computed from the first derivative curve were used as inputs, whereas the measured depth of penetration and weld bead width were used as output of the respective models. Accurate ANFIS models have been developed for predicting the depth of penetration and the weld bead width during TIG welding of 6-mm-thick 316 LN stainless steel plates. A good correlation between the measured and predicted values of weld bead width and depth of penetration were observed in the developed models. The performance of the ANFIS models are compared with that of the ANN models.

  17. GOME-2A retrievals of tropospheric NO2 in different spectral ranges – influence of penetration depth

    Directory of Open Access Journals (Sweden)

    L. K. Behrens

    2018-05-01

    Full Text Available In this study, we present a novel nitrogen dioxide (NO2 differential optical absorption spectroscopy (DOAS retrieval in the ultraviolet (UV spectral range for observations from the Global Ozone Monitoring Instrument 2 on board EUMETSAT's MetOp-A (GOME-2A satellite. We compare the results to those from an established NO2 retrieval in the visible (vis spectral range from the same instrument and investigate how differences between the two are linked to the NO2 vertical profile shape in the troposphere.As expected, radiative transfer calculations for satellite geometries show that the sensitivity close to the ground is higher in the vis than in the UV spectral range. Consequently, NO2 slant column densities (SCDs in the vis are usually higher than in the UV if the NO2 is close to the surface. Therefore, these differences in NO2 SCDs between the two spectral ranges contain information on the vertical distribution of NO2 in the troposphere. We combine these results with radiative transfer calculations and simulated NO2 fields from the TM5-MP chemistry transport model to evaluate the simulated NO2 vertical distribution.We investigate regions representative of both anthropogenic and biomass burning NO2 pollution. Anthropogenic air pollution is mostly located in the boundary layer close to the surface, which is reflected by large differences between UV and vis SCDs of  ∼  60 %. Biomass burning NO2 in contrast is often uplifted into elevated layers above the boundary layer. This is best seen in tropical Africa south of the Equator, where the biomass burning NO2 is well observed in the UV, and the SCD difference between the two spectral ranges is only  ∼  36 %. In tropical Africa north of the Equator, however, the biomass burning NO2 is located closer to the ground, reducing its visibility in the UV.While not enabling a full retrieval of the vertical NO2 profile shape in the troposphere, our results can help to constrain the vertical

  18. Study on penetration-induced initiation of energetic fragment

    Science.gov (United States)

    Qiao, Xiangxin; Xu, Heyang

    2017-09-01

    In order to investigate penetration-induced initiation of energetic fragment penetrating target, PTFE/Al (mass ratio 73.5/26.5) pressed and sintered into a Ф8mm × 8mm cylinder. To form energetic fragment, the cylinder was put into a closed container made by 35CrMnSiA. The container is 12mm long, 2mm thick. Energetic fragments were launched by a 14.5mm ballistic gun with a series of velocities and the penetrate process was simulated by AUTODYN-3D. The results show that the stress peak of energetic material exceed the initiation threshold, and energetic material will deflagrate, when energetic fragments impact velocity more than 800 m/s. The research results can provide reference for designs of energetic warhead.

  19. In-Depth Case Studies of Superfund Reuse

    Science.gov (United States)

    SRI’s in-depth case studies explore Superfund reuse stories from start to finish. Their purpose is to see what redevelopment strategies worked, acknowledge reuse barriers and understand how communities overcame the barriers to create new reuse outcomes.

  20. An In-depth Study on Semitransparent amorphous Silicon Sensors

    International Nuclear Information System (INIS)

    Fernandez, M. G.; Ferrando, A.; Josa, M. I.; Molinero, A.; Oller, J. C.; Arce, P.; Calvo, E.; Figueroa, C. F.; Garcia, N.; Rodrigo, T.; Vila, I.; Virto, A. L.

    1999-01-01

    Semitransparent amorphous silicon sensors have been proposed as the 2D positioning sensors for the link system of the CMS alignment: An in-depth study of the actual performance of these sensors is here reported. (Author) 8 refs

  1. A quantitative study of nanoparticle skin penetration with interactive segmentation.

    Science.gov (United States)

    Lee, Onseok; Lee, See Hyun; Jeong, Sang Hoon; Kim, Jaeyoung; Ryu, Hwa Jung; Oh, Chilhwan; Son, Sang Wook

    2016-10-01

    In the last decade, the application of nanotechnology techniques has expanded within diverse areas such as pharmacology, medicine, and optical science. Despite such wide-ranging possibilities for implementation into practice, the mechanisms behind nanoparticle skin absorption remain unknown. Moreover, the main mode of investigation has been qualitative analysis. Using interactive segmentation, this study suggests a method of objectively and quantitatively analyzing the mechanisms underlying the skin absorption of nanoparticles. Silica nanoparticles (SNPs) were assessed using transmission electron microscopy and applied to the human skin equivalent model. Captured fluorescence images of this model were used to evaluate degrees of skin penetration. These images underwent interactive segmentation and image processing in addition to statistical quantitative analyses of calculated image parameters including the mean, integrated density, skewness, kurtosis, and area fraction. In images from both groups, the distribution area and intensity of fluorescent silica gradually increased in proportion to time. Since statistical significance was achieved after 2 days in the negative charge group and after 4 days in the positive charge group, there is a periodic difference. Furthermore, the quantity of silica per unit area showed a dramatic change after 6 days in the negative charge group. Although this quantitative result is identical to results obtained by qualitative assessment, it is meaningful in that it was proven by statistical analysis with quantitation by using image processing. The present study suggests that the surface charge of SNPs could play an important role in the percutaneous absorption of NPs. These findings can help achieve a better understanding of the percutaneous transport of NPs. In addition, these results provide important guidance for the design of NPs for biomedical applications.

  2. An energy approach study of the penetration of concrete by rigid missiles

    International Nuclear Information System (INIS)

    Guirgis, Sameh; Guirguis, Ehab

    2009-01-01

    This paper presents an energy approach for investigating the penetration of concrete by rigid missiles and the associated phenomena. However, the principal assumptions made here must be validated experimentally before giving the proposed subject further considerations. In the following, a new measure for concrete resistance to penetration by hard missiles is presented. The suggested term for this measure is 'the Volumetric Crushing Energy Density' of concrete which can be described as the energy required for converting a unit volume of concrete to separate particles under compressive loading so that the particles of the crushed volume meet certain gradation criteria. Using this quantity, an explanation of the scale effect is postulated. Moreover, a dimensionless semi-analytical formula for the penetration depth of a rigid missile in a concrete target is proposed which includes a large number of the variables of the problem. The formula assumes that the penetration incident may include several successive phases where the set of variables that governs the impact is different during each phase, and the variables that characterize the impact during each phase correlate in a different manner as well. Furthermore, many of the penetration depth formulae available in the literature are rewritten according to the formula proposed here where the concrete penetration resistance of any incident is estimated by modifying the resistance of 'reference impact incidents.' The rewritten formulae show the wide variation of the values of concrete resistance which are implicitly included in the original formulae. Finally, the proposed formula is applied using data of penetration experiments presented by Forrestal et al. [Forrestal, M.J., Altman, B.S., Cargile, J.D., Hanchak, S.J., 1994. An empirical equation for penetration depth of ogive-nose projectiles into concrete targets. Int. J. Impact Eng. 15(4), 395-405; Forrestal, M.J., Frew, D.J., Hickerson, J.P., Rohwer, T.A., 2003

  3. Atomistic simulation of femtosecond laser pulse interactions with a copper film: Effect of dependency of penetration depth and reflectivity on electron temperature

    Science.gov (United States)

    Amouye Foumani, A.; Niknam, A. R.

    2018-01-01

    The response of copper films to irradiation with laser pulses of fluences in the range of 100-6000 J/m2 is simulated by using a modified combination of a two-temperature model (TTM) and molecular dynamics (MD). In this model, the dependency of the pulse penetration depth and the reflectivity of the target on electron temperature are taken into account. Also, the temperature-dependent electron-phonon coupling factor, electron thermal conductivity, and electron heat capacity are used in the simulations. Based on this model, the dependence of the integral reflectivity on pulse fluence, the changes in the film thickness, and the evolution of density and electron and lattice temperatures are obtained. Moreover, snapshots that show the melting and disintegration processes are presented. The disintegration starts at a fluence of 4200 J/m2, which corresponds with an absorbed fluence of 616 J/m2. The calculated values of integral reflectivity are in good agreement with the experimental data. The inclusion of such temperature-dependent absorption models in the TTM-MD method would facilitate the comparison of experimental data with simulation results.

  4. Deep ocean model penetrator experiments

    International Nuclear Information System (INIS)

    Freeman, T.J.; Burdett, J.R.F.

    1986-01-01

    Preliminary trials of experimental model penetrators in the deep ocean have been conducted as an international collaborative exercise by participating members (national bodies and the CEC) of the Engineering Studies Task Group of the Nuclear Energy Agency's Seabed Working Group. This report describes and gives the results of these experiments, which were conducted at two deep ocean study areas in the Atlantic: Great Meteor East and the Nares Abyssal Plain. Velocity profiles of penetrators of differing dimensions and weights have been determined as they free-fell through the water column and impacted the sediment. These velocity profiles are used to determine the final embedment depth of the penetrators and the resistance to penetration offered by the sediment. The results are compared with predictions of embedment depth derived from elementary models of a penetrator impacting with a sediment. It is tentatively concluded that once the resistance to penetration offered by a sediment at a particular site has been determined, this quantity can be used to sucessfully predict the embedment that penetrators of differing sizes and weights would achieve at the same site

  5. Depth study of insular shelf electric sounding Adelaida anomaly (Rivera)

    International Nuclear Information System (INIS)

    Cicalese, H.

    1983-01-01

    In the framework of the Uranium prospecting programme, the DINAMIGE geophysical equipment have made a study. It was about the depth of insular shelf electric sounding on the anomalies zone of Adelaida. This equipment carried out a study of the following subjects: geographical location, geologic framework, geophysical intervention, developed works, methods and material and results

  6. Study on mixed convective flow penetration into subassembly from reactor hot plenum in FBRs

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, J.; Ohshima, H.; Kamide, H.; Ieda, Y. [Power Reactor and Nuclear Fuel Development Corporation, Ibaraki (Japan)

    1995-09-01

    Fundamental experiments using water were carried out in order to reveal the phenomenon of mixed convective flow penetration into subassemblies from a reactor`s upper plenum of fast breeder reactors. This phenomenon appears under a certain natural circulation conditions during the operation of the direct reactor auxiliary cooling system for decay heat removal and might influence the natural circulation head which determines the core flow rate and therefore affects the core coolability. In the experiment, a simplified model which simulates an upper plenum and a subassembly was used and the ultrasonic velocity profile monitor as well as thermocouples were applied for the simultaneous measurement of velocity and temperature distributions in the subassembly. From the measured data, empirical equations related to the penetration flow onset condition and the penetration depth were obtained using relevant parameters which were derived from dimensional analysis.

  7. In-Depth Study Of European Union Fiscal Approximation

    Directory of Open Access Journals (Sweden)

    Andreea Roxana TOMI

    2011-05-01

    Full Text Available The current study presents a viewpoint on the EU fiscal policy contents, advocating the need for an in-depth understanding and acceleration of the 27 national fiscal system components and the creation of the EU Tax System that would enable the Single Market operation and the enforcement of the four fundamental liberties within the European Union. In the author’s opinion, the extant common fiscal policy elements are only marginal, while the actions aimed at an in-depth understanding of a broad fiscal policy are essential to the extent they point at both direct and indirect taxation aspects whose approximation is a priority.

  8. A Comparative Study Of Source Location And Depth Estimates From ...

    African Journals Online (AJOL)

    ... the analytic signal amplitude (ASA) and the local wave number (LWN) of the total intensity magnetic field. In this study, a synthetic magnetic field due to four buried dipoles was analysed to show that estimates of source location and depth can be improved significantly by reducing the data to the pole prior to the application ...

  9. Copper foliar sorption: study of cuticular uptake and penetration

    International Nuclear Information System (INIS)

    Chamel, Andre; Bougie, Bernadette

    1977-01-01

    Results show that copper is easily retained by enzymatically isolated cuticles from pear leaves discs. The sorption is very rapid during the first hour, then progressively slower with increasing time. Upper and lower cuticles exhibit the same sorption when immersed, but the sorption by the upper internal surface is greater than that by the external surface. Sorption depends on the dates of sampling of the leaves and vegetal species. The variation of the process with concentrations is hyperbolic. The retained copper may be partially exchanged: from 16 to 95% after 24 hours of exchange in a cupric solution, as the Cu concentration increases from 10 -6 to 10 -2 M. The penetration of copper through astomatous cuticular discs is extremely reduced if there is pure water in the receiver unit [fr

  10. Tracheal palpation to assess endotracheal tube depth: an exploratory study.

    Science.gov (United States)

    McKay, William P; Klonarakis, Jim; Pelivanov, Vladko; O'Brien, Jennifer M; Plewes, Chris

    2014-03-01

    Correct placement of the endotracheal tube (ETT) occurs when the distal tip is in mid-trachea. This study compares two techniques used to place the ETT at the correct depth during intubation: tracheal palpation vs placement at a fixed depth at the patient's teeth. With approval of the Research Ethics Board, we recruited American Society of Anesthesiologists physical status I-II patients scheduled for elective surgery with tracheal intubation. Clinicians performing the tracheal intubations were asked to "advance the tube slowly once the tip is through the cords". An investigator palpated the patient's trachea with three fingers spread over the trachea from the larynx to the sternal notch. When the ETT tip was felt in the sternal notch, the ETT was immobilized and its position was determined by fibreoptic bronchoscopy. The position of the ETT tip was compared with our hospital standard, which is a depth at the incisors or gums of 23 cm for men and 21 cm for women. The primary outcome was the incidence of correct placement. Correct placement of the ETT was defined as a tip > 2.5 cm from the carina and > 3.5 cm below the vocal cords. Movement of the ETT tip was readily palpable in 77 of 92 patients studied, and bronchoscopy was performed in 85 patients. Placement by tracheal palpation resulted in more correct placements (71 [77%]; 95% confidence interval [CI] 74 to 81) than hospital standard depth at the incisors or gums (57 [61%]; 95% CI 58 to 66) (P = 0.037). The mean (SD) placement of the ETT tip in palpable subjects was 4.1 (1.7) cm above the carina, 1.9 cm (1.5-2.3 cm) below the ideal mid-tracheal position. Tracheal palpation requires no special equipment, takes only a few seconds to perform, and may improve ETT placement at the correct depth. Further studies are warranted.

  11. A controlled monitoring study of simulated clandestine graves using 3D ground penetrating radar

    CSIR Research Space (South Africa)

    van Schoor, Michael

    2017-06-01

    Full Text Available A controlled three-dimensional ground penetrating radar monitoring study over simulated clandestine graves was conducted near Pretoria, South Africa, in which the detectability of graves as a function of post-burial interval was assessed...

  12. Electroacoustic Process Study of Plasma Sparker Under Different Water Depth

    KAUST Repository

    Huang, Yifan

    2015-01-05

    The plasma sparker has been applied in oceanic high-resolution seismic exploration for decades. Normally it is towed on the water surface. This is suitable for shallow water, but if the water depth is great, the resolution will decrease dramatically, especially in the horizontal direction. This paper proposes the concept of a deep-towed plasma sparker and presents an experimental study of plasma sparker performance in terms of electric parameters, bubble behavior, and acoustic characteristics. The results show that hydrostatic pressure at a source depth ranging from 1 to 2000 m has a negligible influence on the electric parameters but a strong influence on bubble behavior, wherein both the maximum bubble radius and oscillation period are decreased. The collapse pulse vanishes when the source depth reaches 1000 m or deeper, and no bubble oscillation can be distinguished. The source level (evaluated by the expansion pulse) is also decreased as the source depth increases; moreover, the greater the discharge energy, the smaller the source level loss. The discharge energy per electrode should be greater than 20 J for the deep-towed plasma sparker, which can make the source level loss induced by hydrostatic pressure smaller than the transmission loss. The fast Fourier transform (FFT) results show that the dominant energy is around 20 kHz, which is mainly induced by the expansion pulse and its oscillation. According to the simulation results, the fundamental frequency of the acoustic waveform increases with source depth in accord with a log linear trend, and also reaches tens of kilohertz in deep water. So, before the development of deep-towed plasma sparker, a new technical solution will need to be developed to solve this problem. © 1976-2012 IEEE.

  13. A study of the effects of penetration framing on steel containment buckling capacity

    International Nuclear Information System (INIS)

    Baker, W.E.; Butler, T.A.

    1987-05-01

    Polycarbonate cylinders modeling steel containment structures were tested to study the effects of different framing designs around large penetrations on the static buckling capacity of containments. Two of the four models had equipment hatch penetrations and two had personnel airlock penetrations. Both types of models were tested with axial and shear loads as framing was incrementally added. Results indicate that, for the models constructed of polycarbonate, buckling is influenced minimally with added framing. Numerical results support the experimental results. Extrapolation of the results to containment constructed under field conditions with prototypic steel materials is discussed and further testing is recommended

  14. On-scene time and outcome after penetrating trauma: an observational study

    DEFF Research Database (Denmark)

    Funder, Kamillia S.; Steinmetz, Jacob; Petersen, John Asger

    2011-01-01

    This was an observational cohort study of penetrating trauma patients treated by the Mobile Emergency Care Unit in Copenhagen with a 30-day follow-up. Between January 2002 and September 2009, data were prospectively registered regarding the anatomical location of the trauma, time intervals and procedures performed......-scene time might be important in penetrating trauma, and ALS procedures should not delay transport to definite care at the hospital....

  15. Penetration Evaluation of Explosively Formed Projectiles Through Air and Water Using Insensitive Munition: Simulative and Experimental Studies

    Directory of Open Access Journals (Sweden)

    M. Ahmed

    2016-02-01

    Full Text Available The process of formation, flying, penetration of explosively-formed projectiles (EFP and the effect of water on performance of the charge for underwater applications is simulated by Ansysis Autodyn 2D-Hydro code. The main objective of an explosively formed projectile designed for underwater applications is to disintegrate the target at longer standoff distances. In this paper we have simulated the explosively formed projectile from OFHC-Copper liner for 1200 conical angle. The Affect of water on the penetration of EFP is determined by simulations from Ansysis Autodyn 2-D Hydrocode and by varying depth of water from 1CD-5CD. The depth of penetration against steel target is measured experimentally. Flash X-Ray Radiography (FXR is used to capture EFP jet formation and its penetration against target is measured by depth of penetration experiments. Simulation results are compared with experimental results. The difference in simulated and experimental results for depth of penetration is about 7 mm, which lies within favorable range of error. The jet formation captured from FXR is quite clear and jet velocity determined from Flash X-ray radiography is the same as the ones obtained by using other high explosives. Therefore, it is indicated that Insensitive Munition (8701 can be utilized instead of Polymer Bonded Explosives (PBX for air and underwater environments with great reliability and without any hazard.

  16. Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

    Science.gov (United States)

    Ouchi, Kentaro; Sugiyama, Kazuna

    2016-04-01

    Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.

  17. An experimental study of aerosol penetration through horizontal tubes and strom-type loops

    International Nuclear Information System (INIS)

    Wong, F.S.; McFarland, A.R.; Anand, N.K.

    1996-01-01

    Because some designers of aerosol transport systems use the assumption that aerosol penetration through a system is maximized of the flow Reynolds number is 2,800, we have conducted tests to determine if such an assumption is appropriate. Although we do not believe that optimal performance of an aerosol sample transport system can be presented solely in terms of the Reynolds number, we have presented our results in terms of that parameter to compare our work with the results of an earlier study. Two types of experiments were performed. First, the penetration of liquid aerosol particles through horizontal tubes was experimentally investigated for a range of design and operational conditions. For a particle size of 10 μm aerodynamic diameter, the maximum penetration through a 6.7 mm diameter tube was associated with a Reynolds number of approximately 2,000; the maximum penetration through a tube of 15.9 mm occurred at a Reynolds number of about 3,000; and the maximum penetration through a 26.7 mm diameter tube occurred at about 4,000. It was also experimentally demonstrated that for a fixed flow rate through a horizontal tube, there is an optimum tube diameter for which the aerosol penetration is a maximum. An early study dealing with aerosol particle penetration through a 16.8 mm inside diameter loop of tubing (two vertical tubes, two horizontal tubes and three 90 degrees bends) suggested there was a fixed Reynolds number for optimal aerosol penetration independent of particle size. Those experiments were repeated here and the agreement with those tests is excellent. 16 refs., 8 figs., 3 tabs

  18. Evaluation of penetration and scattering components in conventional pinhole SPECT: phantom studies using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Deloar, Hossain M; Watabe, Hiroshi; Aoi, Toshiyuki; Iida, Hidehiro

    2003-01-01

    In quantitative pinhole SPECT, photon penetration through the collimator edges (penetration), and photon scattering by the object (object scatter) and collimator (collimator scatter) have not been investigated rigorously. Monte Carlo simulation was used to evaluate these three physical processes for different tungsten knife-edge pinhole collimators using uniform, hotspot and donut phantoms filled with 201 Tl, 99m Tc, 123 I and 131 I solutions. For the hotspot phantom, the penetration levels with respect to total counts for a 1 mm pinhole aperture were 78%, 28% and 23% for 131 I, 123 I and 99m Tc, respectively. For a 2 mm aperture, these values were 65% for 131 I, 16% for 123 I and 12% for 99m Tc. For all pinholes, 201 Tl penetration was less than 4%. The evaluated scatter (from object and collimator) with a hotspot phantom for the 1 mm pinhole was 24%, 16%, 18% and 13% for 201 Tl, 99m Tc, 123 I and 131 I, respectively. Summation of the object and collimator scatter for the uniform phantom was approximately 20% higher than that for the hotspot phantom. Significant counts due to penetration and object and collimator scatter in the reconstructed image were observed inside the core of the donut phantom. The collimator scatter can be neglected for all isotopes used in this study except for 131 I. Object scatter correction for all radionuclides used in this study is necessary and correction for the penetration contribution is necessary for all radionuclides but 201 Tl

  19. The isolated perfused human skin flap model: A missing link in skin penetration studies?

    Science.gov (United States)

    Ternullo, Selenia; de Weerd, Louis; Flaten, Gøril Eide; Holsæter, Ann Mari; Škalko-Basnet, Nataša

    2017-01-01

    Development of effective (trans)dermal drug delivery systems requires reliable skin models to evaluate skin drug penetration. The isolated perfused human skin flap remains metabolically active tissue for up to 6h during in vitro perfusion. We introduce the isolated perfused human skin flap as a close-to-in vivo skin penetration model. To validate the model's ability to evaluate skin drug penetration the solutions of a hydrophilic (calcein) and a lipophilic (rhodamine) fluorescence marker were applied. The skin flaps were perfused with modified Krebs-Henseleit buffer (pH7.4). Infrared technology was used to monitor perfusion and to select a well-perfused skin area for administration of the markers. Flap perfusion and physiological parameters were maintained constant during the 6h experiments and the amount of markers in the perfusate was determined. Calcein was detected in the perfusate, whereas rhodamine was not detectable. Confocal images of skin cross-sections shoved that calcein was uniformly distributed through the skin, whereas rhodamine accumulated in the stratum corneum. For comparison, the penetration of both markers was evaluated on ex vivo human skin, pig skin and cellophane membrane. The proposed perfused flap model enabled us to distinguish between the penetrations of the two markers and could be a promising close-to-in vivo tool in skin penetration studies and optimization of formulations destined for skin administration. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. A study on the particle penetration in RMS Right Single Quotation Marks particle transport system

    International Nuclear Information System (INIS)

    Son, S. M.; Oh, S. H.; Choi, C. R.

    2014-01-01

    In nuclear facilities, a radiation monitoring system (RMS) monitors the exhaust gas containing the radioactive material. Samples of exhaust gas are collected in the downstream region of air cleaning units (ACUs) in order to examine radioactive materials. It is possible to predict an amount of radioactive material by analyzing the corrected samples. Representation of the collected samples should be assured in order to accurately sense and measure of radioactive materials. The radius of curvature is mainly 5 times of tube diameter. Sometimes, a booster fan is additionally added to enhance particle penetration rate... In this study, particle penetrations are calculated to evaluate particle penetration rate with various design parameters (tube lengths, tube declined angles, radius of curvatures, etc). The particle penetration rates have been calculated for several elements in the particle transport system. In general, the horizontal length of tube and the number of bending tube have a big impact on the penetration rate in the particle transport system. If the sampling location is far from the radiation monitoring system, additional installation of booster fans could be considered in case of large diameter tubes, but is not recommended in case of small diameter tube. In order to enhance particle penetration rate, the following works are recommended by priority. 1) to reduce the interval between sampling location and radiation monitoring system 2) to reduce the number of the bending tube

  1. A Study on Strategy Establishment for Foreign Market Penetrating of Nuclear Technology Venture Business

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ki Dong; Kim, S. S.; Choi, Y. D.; Park, C. S.; Bae, C. I.; Chung, J. M.; Roe, S. P

    2007-05-15

    The objective of this study is to suggest feasible strategy for foreign market penetration of nuclear venture technology business. Especially, this study focuses on the technology and product export to the Frankfurt-Hoechst Industrial Park in Germany. This study analyzed the operating system of German Industrial Park, especially the Frankfurt-Hoechst Industrial Park. This study also analyzed the current status of Industrial Science Parks in Northern European countries such as Finland, Sweden, and England. Then, this study suggested the strategy for nuclear technology venture business to penetrate German export market effectively.

  2. A Study on Strategy Establishment for Foreign Market Penetrating of Nuclear Technology Venture Business

    International Nuclear Information System (INIS)

    Song, Ki Dong; Kim, S. S.; Choi, Y. D.; Park, C. S.; Bae, C. I.; Chung, J. M.; Roe, S. P.

    2007-05-01

    The objective of this study is to suggest feasible strategy for foreign market penetration of nuclear venture technology business. Especially, this study focuses on the technology and product export to the Frankfurt-Hoechst Industrial Park in Germany. This study analyzed the operating system of German Industrial Park, especially the Frankfurt-Hoechst Industrial Park. This study also analyzed the current status of Industrial Science Parks in Northern European countries such as Finland, Sweden, and England. Then, this study suggested the strategy for nuclear technology venture business to penetrate German export market effectively

  3. In-depth Cultural Studies in Multicultural Group

    Directory of Open Access Journals (Sweden)

    Siliņa-Jasjukeviča Gunta

    2016-12-01

    Full Text Available There is much research and educational practices at all levels of education on how to deal with promoting acceptance and understanding between different cultures. A cultural study forms an important part of shaping intercultural understanding. The aim of the research is to analyze an innovative way of incorporating cultural studies in teacher education program from the perspective of encouraging multinational students to reveal common values within diverse manifestations of different cultures. The present article describes a qualitative study of multinational students’ experiences in international project related to the learning about Nordic and Baltic cultural traditions. In the conclusion of the article, the efficiency of the structure of content and the process of in-depth cultural studies are analyzed. The discussion contains problems for further research of this topic.

  4. CSDA range, stopping power and mean penetration depth energy relationships in some hydrocarbons and biologic materials for 10 eV to 100 MeV with the modified Rohrlich-Carlson model

    Energy Technology Data Exchange (ETDEWEB)

    Guemues, Hasan [Ondokuz Mayis University, Department of Physics, Faculty of Sciences and Arts, Samsun (Turkey); Bentabet, Abdelouahab [Bordj Bou Arreridj University, LCVRN, SNVSTU Faculty, El Anasser (Algeria)

    2017-05-15

    In this study, for some hydrocarbons and biological compounds, stopping power formula are presented, being valid for low and intermediate electron energies. In addition, calculation of the continuous slowing down approximation range (CSDA range) from the stopping power is also made. Calculation of the CSDA range for some hydrocarbons: C{sub 2}H{sub 6} (ethane), C{sub 4}H{sub 10} (butane), C{sub 6}H{sub 14} (hexane) C{sub 8}H{sub 18} (octane), C{sub 5}H{sub 5}N{sub 5} (adenine) and C{sub 5}H{sub 5}N{sub 5}O (guanine) have been introduced for incident electrons in the energy range 30 eV to 1 MeV. The range of electrons has been calculated within the continuous slowing down approximation (CSDA) using modified Rohrlich and Carlson formula of stopping power. Besides, we have calculated the mean penetration depths using a spherical geometric model developed by Bentabet (Vacuum 86:1855-1859, 35). The results have been compared with the other theoretical results, Monte Carlo code such as PENELOPE predictions and semi-empirical results. The calculated results of CSDA ranges for electrons in the energy range from 20 eV to 100 MeV are found to be in good agreement to within 10% with available date. (orig.)

  5. Penetrating trauma; experience from Southwest Finland between 1997 and 2011, a retrospective descriptive study.

    Science.gov (United States)

    Inkinen, J; Kirjasuo, K; Gunn, J; Kuttila, K

    2015-08-01

    (1) There is lack of epidemiological data on penetrating trauma in European countries. (2) In Finland most acts of violence are performed under the influence of alcohol. The aim of this study was to determine the incidence and types of injury, treatment and survival of patients with penetrating injuries to the thorax and abdomen. This study includes two trauma centers with combined catchment area of approximately 720,000 patients. Patients were identified from patient records using ICD-10 codes. Patients were predominantly young males and they were stab victims. The average yearly incidence for penetrating trauma was 0.9/100,000 inhabitants. Thirteen percent of patients admitted gave a negative toxicology screen or breathalyzer test for alcohol. Twenty two percent of wounds were self-inflicted. Fifty five percent of patients received a chest tube and 30 patients (23%) underwent emergent thoracotomy after sustaining critical injury to the thorax. A considerable proportion (12%) of the study group also later died due to alcohol and/or violence, highlighting the psychosocial co-morbidity among penetrating trauma victims. Chest tube insertion is a skill to be mastered by any on-call physician. This simple procedure can be potentially life-saving. There is also a call for assessment of psychosocial well-being among penetrating trauma victims.

  6. A comprehensive study on Li-ion battery nail penetrations and the possible solutions

    International Nuclear Information System (INIS)

    Zhao, Rui; Liu, Jie; Gu, Junjie

    2017-01-01

    Li-ion batteries are the state-of-the-art power sources for portable electronics, electric vehicles, and aerospace applications. The safety issues regarding Li-ion batteries arouse particular attentions after several accidents reported in recent years. Among various abuse conditions, nail penetration is one of the most dangerous for Li-ion batteries due to the accumulated heat generation, which could give rise to the thermal runaway and could damage entire energy storage system. In this paper, an electrochemical-thermal coupling model is developed to study the nail penetration process of Li-ion batteries. By introducing joule heating at the nail location, the model shows good agreement with the testing results. With this verified model, a comprehensive parametric study is carried out to investigate the effects of battery capacity, internal resistance, and nail diameter on the electrochemical and thermal behaviors of Li-ion batteries during the penetration processes. Furthermore, three possible solutions to prevent the thermal runaway, which includes decreasing the state of charge, improving heat dissipation, and increasing contact resistance, are compared and discussed in detail based on a series of simulations. - Highlights: • A coupling model is developed to simulate Li-ion battery nail penetrations. • A contact resistance – contact area curve is plotted based on experiments. • Simulation results show good agreements with nail tests. • The behaviors of Li-ion batteries in different penetration scenarios are studied. • Possible strategies to prevent thermal runaway are investigated and discussed.

  7. Application of a Microstructure-Based ISV Plasticity Damage Model to Study Penetration Mechanics of Metals and Validation through Penetration Study of Aluminum

    Directory of Open Access Journals (Sweden)

    Yangqing Dou

    2017-01-01

    Full Text Available A developed microstructure-based internal state variable (ISV plasticity damage model is for the first time used for simulating penetration mechanics of aluminum to find out its penetration properties. The ISV damage model tries to explain the interplay between physics at different length scales that governs the failure and damage mechanisms of materials by linking the macroscopic failure and damage behavior of the materials with their micromechanical performance, such as void nucleation, growth, and coalescence. Within the continuum modeling framework, microstructural features of materials are represented using a set of ISVs, and rate equations are employed to depict damage history and evolution of the materials. For experimental calibration of this damage model, compression, tension, and torsion straining conditions are considered to distinguish damage evolutions under different stress states. To demonstrate the reliability of the presented ISV model, that model is applied for studying penetration mechanics of aluminum and the numerical results are validated by comparing with simulation results yielded from the Johnson-Cook model as well as analytical results calculated from an existing theoretical model.

  8. Penetrating abdominal injuries in children: a study of 33 cases ...

    African Journals Online (AJOL)

    Background: Trauma is gradually becoming a major cause of disability and it can be of any form, physical or emotional. For the surgeon the physical form is of major interest, especially its causes and incidence, which can be influenced by environmental or social factors. Aim: The aim of this work was to study the incidence, ...

  9. Materials properties of hafnium and zirconium silicates: Metal interdiffusion and dopant penetration studies

    Science.gov (United States)

    Quevedo Lopez, Manuel Angel

    Hafnium and Zirconium based gate dielectrics are considered potential candidates to replace SiO2 or SiON as the gate dielectric in CMOS processing. Furthermore, the addition of nitrogen into this pseudo-binary alloy has been shown to improve their thermal stability, electrical properties, and reduce dopant penetration. Because CMOS processing requires high temperature anneals (up to 1050°C), it is important to understand the diffusion properties of any metal associated with the gate dielectric in silicon at these temperatures. In addition, dopant penetration from the doped polysilicon gate into the Si channel at these temperatures must also be studied. Impurity outdiffusion (Hf, Zr) from the dielectric, or dopant (B, As, P) penetration through the dielectric into the channel region would likely result in deleterious effects upon the carrier mobility. In this dissertation extensive thermal stability studies of alternate gate dielectric candidates ZrSixOy and HfSixO y are presented. Dopant penetration studies from doped-polysilicon through HfSixOy and HfSixOyNz are also presented. Rutherford Backscattering Spectroscopy (RBS), Heavy Ion RBS (HI-RBS), X-ray Photoelectron Spectroscopy (XPS), High Resolution Transmission Electron Microscopy (HR-TEM), and Time of Flight and Dynamic Secondary Ion Mass Spectroscopy (ToF-SIMS, D-SIMS) methods were used to characterize these materials. The dopant diffusivity is calculated by modeling of the dopant profiles in the Si substrate. In this disseration is reported that Hf silicate films are more stable than Zr silicate films, from the metal interdiffusion point of view. On the other hand, dopant (B, As, and P) penetration is observed for HfSixO y films. However, the addition of nitrogen to the Hf - Si - O systems improves the dopant penetration properties of the resulting HfSi xOyNz films.

  10. Experimental Study of Bacterial Penetration into Chalk Rock: Mechanisms and Effect on Permeability

    DEFF Research Database (Denmark)

    Halim, Amalia Yunita; Shapiro, Alexander; Eliasson Lantz, Anna

    2014-01-01

    Bacterial selective plugging is one of the mechanisms through which microorganisms can be applied for enhanced oil recovery, as bacteria can plug the water-swept zones of a reservoir, thus altering the flow paths and improving sweep efficiency. However, complete understanding of the penetration...... behavior of bacteria is lacking, especially in chalk formations where characteristic pore throat sizes are comparable with the sizes of bacterial cells. In this study, two bacterial strains, Bacillus licheniformis 421 (spore-forming) and Pseudomonas putida K12 (non-spore forming) were used to investigate...... the penetration of bacteria into chalk and its effect on permeability reduction. The core plugs were produced from Stevns Klint outcrop with low permeability (2–4 mD) and with pore sizes comparable to bacterial sizes. Both types of bacteria were able to penetrate and to be transported through the cores to some...

  11. Depth-Sensing Microindentation Studies of Melt Spun Al-12wt%Si-0.5wt%Sb Alloys

    International Nuclear Information System (INIS)

    Uzun, O.

    2004-01-01

    In this study, the indentation load-penetration depth curves of melt spun ribbons were measured under different peak load levels. The unloading segments of these curves were analyzed using widely adopted Oliver and Pharr method. It was found that both hardness and Youngs modulus exhibit significant peak load dependence. Empirical approaches were then proposed to determine the load independent hardness, H0, and modulus. The load independent hardness (1135.07 and 756.72 MPa) and modulus (13.4 and 7.2 GPa) values were then calculated for wheel and air side of the ribbon, respectively. The results showed that the reduced elastic modulus increases with increasing hardness

  12. Universal doping evolution of the superconducting gap anisotropy in single crystals of electron-doped Ba(Fe1‑x Rh x )2As2 from London penetration depth measurements

    Science.gov (United States)

    Kim, Hyunsoo; Tanatar, M. A.; Martin, C.; Blomberg, E. C.; Ni, Ni; Bud’ko, S. L.; Canfield, P. C.; Prozorov, R.

    2018-06-01

    Doping evolution of the superconducting gap anisotropy was studied in single crystals of 4d-electron doped Ba(Fe1‑x Rh x )2As2 using tunnel diode resonator measurements of the temperature variation of the London penetration depth . Single crystals with doping levels representative of an underdoped regime x  =  0.039 ( K), close to optimal doping x  =  0.057 ( K) and overdoped x  =  0.079 ( K) and x  =  0.131( K) were studied. Superconducting energy gap anisotropy was characterized by the exponent, n, by fitting the data to the power-law, . The exponent n varies non-monotonically with x, increasing to a maximum n  =  2.5 for x  =  0.079 and rapidly decreasing towards overdoped compositions to 1.6 for x  =  0.131. This behavior is qualitatively similar to the doping evolution of the superconducting gap anisotropy in other iron pnictides, including hole-doped (Ba,K)Fe2As2 and 3d-electron-doped Ba(Fe,Co)2As2 superconductors, finding a full gap near optimal doping and strong anisotropy toward the ends of the superconducting dome in the T-x phase diagram. The normalized superfluid density in an optimally Rh-doped sample is almost identical to the temperature-dependence in the optimally doped Ba(Fe,Co)2As2 samples. Our study supports the universal superconducting gap variation with doping and pairing at least in iron based superconductors of the BaFe2As2 family.

  13. Estimation of Skin to Subarachnoid Space Depth: An Observational Study.

    Science.gov (United States)

    Hazarika, Rajib; Choudhury, Dipika; Nath, Sangeeta; Parua, Samit

    2016-10-01

    In a patient, the skin to Subarachnoid Space Depth (SSD) varies considerably at different levels of the spinal cord. It also varies from patient to patient at the same vertebral level as per age, sex and Body Mass Index (BMI). Estimation of the skin to SSD reduces complications related to spinal anaesthesia. To measure the skin to SSD in the Indian population and to find a formula for predicting this depth. Three hundred adult patients belonging to American Society of Anaesthesiologist class I and II, undergoing surgery using spinal anaesthesia in various surgical specialities of Gauhati Medical College were selected by systemic sampling for this prospective, observational study. Patients were divided into three groups: Group M containing male patients, Group F containing non-pregnant female patients, and Group PF containing pregnant female's patients. SSD was measured after performing lumbar puncture. The relationship between SSD and patient characteristics were studied, correlated and statistical analysis was used to find a formula for predicting the skin to SSD. Statistical analysis was done using Statistical Package for Social Sciences (SPSS 21.0, Chicago, IL, USA). One-way ANOVA with post-hoc(Bonferroni correction factor) analysis was applied to compare the three groups. Multivariate analysis was done for the covariates followed by a multivariate regression analysis to evaluate the covariates influencing SSD for each group separately. Mean SSD was 4.37±0.31cm in the overall population. SSD in adult males was 4.49±0.19cm which was significantly longer than that observed in female's 4.18±0.39cm which was comparable with SSD in parturient 4.43±0.19 cm. The formula for predicting the skin to SSD in the male population was 1.718+0.077×BMI+0.632×Height, in nonpregnant female population was 1.828+0.077×BMI+0.018×Height+0.007×Age and 0.748+0.209×BMI+4.703×Height-0.054×weight in parturient females, respectively. Skin to SSD correlated with the BMI in all

  14. Design studies of a depth encoding large aperture PET camera

    International Nuclear Information System (INIS)

    Moisan, C.; Rogers, J.G.; Buckley, K.R.; Ruth, T.J.; Stazyk, M.W.; Tsang, G.

    1994-10-01

    The feasibility of a wholebody PET tomograph with the capacity to correct for the parallax error induced by the Depth-Of-Interaction of γ-rays is assessed through simulation. The experimental energy, depth, and transverse position resolutions of BGO block detector candidates are the main inputs to a simulation that predicts the point source resolution of the Depth Encoding Large Aperture Camera (DELAC). The results indicate that a measured depth resolution of 7 mm (FWHM) is sufficient to correct a substantial part of the parallax error for a point source at the edge of the Field-Of-View. A search for the block specifications and camera ring radius that would optimize the spatial resolution and its uniformity across the Field-Of-View is also presented. (author). 10 refs., 1 tab., 5 figs

  15. Quantum finite-depth memory channels: Case study

    International Nuclear Information System (INIS)

    Rybar, Tomas; Ziman, Mario

    2009-01-01

    We analyze the depth of the memory of quantum memory channels generated by a fixed unitary transformation describing the interaction between the principal system and internal degrees of freedom of the process device. We investigate the simplest case of a qubit memory channel with a two-level memory system. In particular, we explicitly characterize all interactions for which the memory depth is finite. We show that the memory effects are either infinite, or they disappear after at most two uses of the channel. Memory channels of finite depth can be to some extent controlled and manipulated by so-called reset sequences. We show that actions separated by the sequences of inputs of the length of the memory depth are independent and constitute memoryless channels.

  16. Developing High PV Penetration Cases for Frequency Response Study of U.S. Western Interconnection: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Jin; Zhang, Yingchen; Veda, Santosh; Elgindy, Tarek; Liu, Yilu

    2017-04-11

    Recent large penetrations of solar photovoltaic (PV) generation and the inertial characteristics of inverter-based generation technologies have caught the attention of those in the electric power industry in the United States. This paper presents a systematic approach to developing test cases of high penetrations of PV for the Western Interconnection. First, to examine the accuracy of the base case model, the Western Electricity Coordinating Council (WECC) model is validated by using measurement data from synchronized phasor measurement units. Based on the 2022 Light Spring case, we developed four high PV penetration cases for the WECC system that are of interest to the industry: 5% PV+15 % wind, 25% PV+15% wind, 45% PV+15% wind, 65% PV+15% wind). Additionally, a method to project PV is proposed that is based on collected, realistic PV distribution information, including the current and future PV power plant locations and penetrations in the WECC system. Both the utility-scale PV plant and residential rooftop PV are included in this study.

  17. An agent-based model to study market penetration of plug-in hybrid electric vehicles

    International Nuclear Information System (INIS)

    Eppstein, Margaret J.; Grover, David K.; Marshall, Jeffrey S.; Rizzo, Donna M.

    2011-01-01

    A spatially explicit agent-based vehicle consumer choice model is developed to explore sensitivities and nonlinear interactions between various potential influences on plug-in hybrid vehicle (PHEV) market penetration. The model accounts for spatial and social effects (including threshold effects, homophily, and conformity) and media influences. Preliminary simulations demonstrate how such a model could be used to identify nonlinear interactions among potential leverage points, inform policies affecting PHEV market penetration, and help identify future data collection necessary to more accurately model the system. We examine sensitivity of the model to gasoline prices, to accuracy in estimation of fuel costs, to agent willingness to adopt the PHEV technology, to PHEV purchase price and rebates, to PHEV battery range, and to heuristic values related to gasoline usage. Our simulations indicate that PHEV market penetration could be enhanced significantly by providing consumers with ready estimates of expected lifetime fuel costs associated with different vehicles (e.g., on vehicle stickers), and that increases in gasoline prices could nonlinearly magnify the impact on fleet efficiency. We also infer that a potential synergy from a gasoline tax with proceeds is used to fund research into longer-range lower-cost PHEV batteries. - Highlights: → We model consumer agents to study potential market penetration of PHEVs. → The model accounts for spatial, social, and media effects. → We identify interactions among potential leverage points that could inform policy. → Consumer access to expected lifetime fuel costs may enhance PHEV market penetration. → Increasing PHEV battery range has synergistic effects on fleet efficiency.

  18. Study of total column atmospheric aerosol optical depth, ozone and ...

    Indian Academy of Sciences (India)

    Extensive observations of the columnar aerosol optical depth (AOD), total column ozone (TCO) and precipitable water content (PWC) have been carried out using the on-line, multi-band solar radiometers onboard ORV Sagar Kanya (Cruise#SK 147B) over Bay of Bengal during 11th-28th August 1999. Aerosol optical and ...

  19. Analysis by numerical calculations of the depth and dynamics of the penetration of ordered cellular structure made by casting from AlSi10Mg eutectic alloy

    Directory of Open Access Journals (Sweden)

    M. Małysza

    2011-07-01

    Full Text Available Owing to high plastic deformability while maintaining stress values constant and relatively low, ordered cellular structures arecharacterised by excellent properties and the ability to dissipate the impact energy. Due to the low weight, structures of this type can beused, among others, for different parts of motor vehicles. For tests, a trapezoidal ordered cellular structure of 50.8 x 50.8 x 25.4 (mmoverall dimensions was selected. It was made as an investment casting from AlSi9Mg eutectic alloy by the method of Rapid Prototyping(RP. During FEM computations using an Abaqus programme, it was assumed that the material is isotropic and exhibits the features of anelastic – plastic body, introducing to calculations the, listed in a table, values of the stress-strain curve obtained in tensile tests performedon a MTS testing machine (10T. The computations used Johnson - Cook model, which is usually sufficiently accurate when modelling thephenomena of penetration of an element by an object of high initial velocity. The performed numerical calculations allowed identification

  20. Study of damaged depth profiles of ion-irradiated PEEK

    Czech Academy of Sciences Publication Activity Database

    Vacík, Jiří; Hnatowicz, Vladimír; Červená, Jarmila; Apel, P. Yu.; Posta, S.; Kobayashi, Y.

    2007-01-01

    Roč. 201, 19-20 (2007), s. 8370-8372 ISSN 0257-8972 R&D Projects: GA MPO(CZ) 1H-PK2/05; GA MŠk 1P04LA213 Institutional research plan: CEZ:AV0Z10480505 Keywords : Oxygen irradiation * Poly-aryl-ether-ether ketone * Thermal neutron depth profiling (TNDP) Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.678, year: 2007

  1. Management of vaginal penetration phobia in Arab women: a retrospective study.

    Science.gov (United States)

    Muammar, Tarfah; McWalter, Patricia; Alkhenizan, Abdullah; Shoukri, Mohamed; Gabr, Alia; Bin, Abdulaziz AlDanah

    2015-01-01

    Vaginal penetration phobia is a common and distressing problem world.wide. It interferes with vaginal penetrative sexual relations, and leads to unconsummated marriage (UCM). This problem may be heightened in Arab women, due to cultural taboos about pain and bleeding, that may be associated with the first coital experience after marriage. Data about this problem is scarce in Arab societies. The aim of this study was to evaluate the response of these women and their husbands to an individualized, psychotherapeutic assessment and treatment to resolve this problem. Retrospective descriptive in a general gynecology community setting over a 6-year period. The study involved a retrospective sequential cohort of 100 Arab couples with UCM due to the woman's VPP. They were evaluated by a female gynecologist in out patient clinics. Data was collected through chart review, and telephone interviews. Final analysis was performed on 100 Arab couples, who satisfied the inclusion criteria. They were followed up to assess their response to an individualized, structured treatment protocol. The treatment combined sex education with systematic desensitization, targeting fear and anxiety as.sociated with vaginal penetration. A total of 96% of the studied group had a successful outcome after an average of 4 sessions. Penetrative intercourse was reported by the tolerance of these women; further pregnancy was achieved in 77.8 % of the infertile couples. Insufficient knowledge of sexual intercourse is a major contributor to the development of VPP in the sampled population. It appears that they respond well to an individualized, structured treatment protocol as described by Hawten 1985 (regardless of other risk factors associated with vaginismus).

  2. Aerosol penetration through capillaries and leaks: experimental studies on the influence of pressure

    International Nuclear Information System (INIS)

    Morton, D.A.V.; Mitchell, J.P.

    1995-01-01

    It is important to understand the movement of aerosols through ultrafine leak-paths with dimensions of similar order to the gas-borne particles when assessing the validity of leak-testing procedures for transport containers for radioactive materials. Experiments have been undertaken to investigate the penetration of micron-sized airborne particles using glass micro-capillaries as model leak-paths. Previous studies demonstrated a simple relationship between air leakage and total particle penetration rates at a constant driving pressure (100 kPa). The present work has demonstrated the importance of pressure in regulating the rate at which the leak-path is plugged by deposited particles. Much of this deposition appears to take place at the entrances of the capillaries where the air-flow converges. (author)

  3. Autoradiographic study of the penetration of radiolabelled dextrans and inulin through non-keratinized oral mucosa in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Alfano, M C; Chasens, A I; Masi, C W [Block Periodontal Research Laboratories, Department of Periodontics and Oral Medicine, Fairleigh Dickinson University, School of Dentistry, Hackensack, New Jersey, U.S.A.

    1977-01-01

    Although a well known barrier effect against the penetration of macromolecules exists at the basement membrane region of epithelial tissues, recent reports suggest that the penetration of smaller molecules may be impeded by this region. Considering the probable importance of the permeability of gingival crevicular tissues in the etiology of inflammatory periodontal disease, the present study was designed to evaluate the barrier function of the basement membrane region of non-keratinized oral mucosal epithelium to a series of radiolabelled penetrating molecules of increasing molecular weight. Tritium labeled inulin (Mw 5,000), dextran 20 (Mw 20,000) and dextran 70 (Mw 70,000) were used as penetrating molecules, and autoradiographic tracer techniques were used to evaluate the barrier function. The study was conducted in vitro to eliminate vascular ''wash-out'' effects and to facilitate study of penetration across the basement membrane region in both directions. The results indicated that although the penetration of inulin and dextran 70 was impeded by the basement membrane region, the penetration of dextran 20 was not affected. Therefore, the barrier function of the basement membrane region is not solely dependent on the molecular weight of the penetration molecule. Mechanisms to account for the findings are described and the significance to periodontal disease is discussed.

  4. Autoradiographic study of the penetration of radiolabelled dextrans and inulin through non-keratinized oral mucosa in vitro

    International Nuclear Information System (INIS)

    Alfano, M.C.; Chasens, A.I.; Masi, C.W.

    1977-01-01

    Although a well known barrier effect against the penetration of macromolecules exists at the basement membrane region of epithelial tissues, recent reports suggest that the penetration of smaller molecules may be impeded by this region. Considering the probable importance of the permeability of gingival crevicular tissues in the etiology of inflammatory periodontal disease, the present study was designed to evaluate the barrier function of the basement membrane region of non-keratinized oral mucosal epithelium to a series of radiolabelled penetrating molecules of increasing molecular weight. Tritium labeled inulin (Mw 5,000), dextran 20 (Mw 20,000) and dextran 70 (Mw 70,000) were used as penetrating molecules, and autoradiographic tracer techniques were used to evaluate the barrier function. The study was conducted in vitro to eliminate vascular ''wash-out'' effects and to facilitate study of penetration across the basement membrane region in both directions. The results indicated that although the penetration of inulin and dextran 70 was impeded by the basement membrane region, the penetration of dextran 20 was not affected. Therefore, the barrier function of the basement membrane region is not solely dependent on the molecular weight of the penetration molecule. Mechanisms to account for the findings are described and the significance to periodontal disease is discussed. (author)

  5. Muon background studies for shallow depth Double - Chooz near detector

    Energy Technology Data Exchange (ETDEWEB)

    Gómez, H. [Laboratoire Astroparticule et Cosmologie (APC) - Université Paris 7. Paris (France)

    2015-08-17

    Muon events are one of the main concerns regarding background in neutrino experiments. The placement of experimental set-ups in deep underground facilities reduce considerably their impact on the research of the expected signals. But in the cases where the detector is installed on surface or at shallow depth, muon flux remains high, being necessary their precise identification for further rejection. Total flux, mean energy or angular distributions are some of the parameters that can help to characterize the muons. Empirically, the muon rate can be measured in an experiment by a number of methods. Nevertheless, the capability to determine the muons angular distribution strongly depends on the detector features, while the measurement of the muon energy is quite difficult. Also considering that on-site measurements can not be extrapolated to other sites due to the difference on the overburden and its profile, it is necessary to find an adequate solution to perform the muon characterization. The method described in this work to obtain the main features of the muons reaching the experimental set-up, is based on the muon transport simulation by the MUSIC software, combined with a dedicated sampling algorithm for shallow depth installations based on a modified Gaisser parametrization. This method provides all the required information about the muons for any shallow depth installation if the corresponding overburden profile is implemented. In this work, the method has been applied for the recently commissioned Double - Chooz near detector, which will allow the cross-check between the simulation and the experimental data, as it has been done for the far detector.

  6. Muon background studies for shallow depth Double - Chooz near detector

    International Nuclear Information System (INIS)

    Gómez, H.

    2015-01-01

    Muon events are one of the main concerns regarding background in neutrino experiments. The placement of experimental set-ups in deep underground facilities reduce considerably their impact on the research of the expected signals. But in the cases where the detector is installed on surface or at shallow depth, muon flux remains high, being necessary their precise identification for further rejection. Total flux, mean energy or angular distributions are some of the parameters that can help to characterize the muons. Empirically, the muon rate can be measured in an experiment by a number of methods. Nevertheless, the capability to determine the muons angular distribution strongly depends on the detector features, while the measurement of the muon energy is quite difficult. Also considering that on-site measurements can not be extrapolated to other sites due to the difference on the overburden and its profile, it is necessary to find an adequate solution to perform the muon characterization. The method described in this work to obtain the main features of the muons reaching the experimental set-up, is based on the muon transport simulation by the MUSIC software, combined with a dedicated sampling algorithm for shallow depth installations based on a modified Gaisser parametrization. This method provides all the required information about the muons for any shallow depth installation if the corresponding overburden profile is implemented. In this work, the method has been applied for the recently commissioned Double - Chooz near detector, which will allow the cross-check between the simulation and the experimental data, as it has been done for the far detector

  7. Approximate relationship between frequency-dependent skin depth resolved from geoelectromagnetic pedotransfer function and depth of investigation resolved from geoelectrical measurements: A case study of coastal formation, southern Nigeria

    Science.gov (United States)

    George, N. J.; Obiora, D. N.; Ekanem, A. M.; Akpan, A. E.

    2016-10-01

    The task involved in the interpretation of Vertical Electrical Sounding (VES) data is how to get unique results in the absence/limited number of borehole information, which is usually limited to information on the spot. Geological and geochemical mapping of electrical properties are usually limited to direct observations on the surface and therefore, conclusions and extrapolations that can be drawn about the system electrical characteristics and possible underlying structures may be masked as geology changes with positions. The electrical resistivity study pedotransfer functions (PTFs) have been linked with the electromagnetic (EM) resolved PTFs at chosen frequencies of skin/penetration depth corresponding to the VES resolved investigation depth in order to determine the local geological attributes of hydrogeological repository in the coastal formation dominated with fine sand. The illustrative application of effective skin depth depicts that effective skin depth has direct relation with the EM response of the local source over the layered earth and thus, can be linked to the direct current earth response functions as an aid for estimating the optimum depth and electrical parameters through comparative analysis. Though the VES and EM resolved depths of investigation at appropriate effective and theoretical frequencies have wide gaps, diagnostic relations characterising the subsurface depth of interest have been established. The determining factors of skin effect have been found to include frequency/period, resistivity/conductivity, absorption/attenuation coefficient and energy loss factor. The novel diagnostic relations and their corresponding constants between 1-D resistivity data and EM skin depth are robust PTFs necessary for checking the accuracy associated with the non-unique interpretations that characterise the 1-D resistivity data, mostly when lithostratigraphic data are not available.

  8. CLINICAL OUTCOME OF PENETRATING KERATOPLASTY IN CORNEAL OPACITIES OF DIFFERENT AETIOLOGY- A CLINICAL STUDY

    Directory of Open Access Journals (Sweden)

    Dipak Bhuyan

    2017-01-01

    Full Text Available BACKGROUND Corneal transplantation or grafting is an operation in which abnormal corneal host tissue is replaced by healthy donor cornea. According to the World Health Organization (WHO, corneal diseases are among the major causes of vision loss and blindness in the world today after cataract and glaucoma. The aim of the study is to- 1. Evaluate the different aetiology of corneal opacity including active infective aetiology as indicated for penetrating keratoplasty. 2. Determine the clinical outcome of penetrating keratoplasty in relation to graft survival, graft rejection and peri-operative complications in different aetiology groups. 3. Determine the final visual outcome. MATERIALS AND METHODS Candidates for keratoplasty were selected from- 1. Eye Bank of Regional Institute of Ophthalmology (R.I.O. 2. R.I.O OPD. The study period was from September 2014 to August 2015. 30 cases were taken in the study. Descriptive statistics were applied to analyse the data wherever necessary. RESULTS 34.6±19.73 yrs. (mean±SD was the mean age at which transplants were done in the study. Out of total 30 cases, 13 (43.33% and 17 (56.66% were male and female, respectively. The different indications for penetrating keratoplasty are- Post ulcer corneal opacity in 14 cases (46.66%, posttraumatic corneal opacity 9 cases (30%, pseudophakic bullous keratopathy 4 cases (13.33%, corneal dystrophy in 2 cases (6.66% and non-healing corneal ulcer in 1 case (3.33%. 16 cases (53.33% showed clear graft till the last follow up while 11 (33.33% cases showed partially clear graft resulting in improved visual outcome while 3 cases (10.00% of the grafts were opaque due to graft failure. CONCLUSION The major indications for penetrating keratoplasty in this part of the world are post ulcer and posttraumatic corneal opacity and majority of them are illiterate agricultural workers who failed to get adequate treatment on time. Graft survival rate is high, which can be attributed to the

  9. The study of heat penetration of kimchi soup on stationary and rotary retorts.

    Science.gov (United States)

    Cho, Won-Il; Park, Eun-Ji; Cheon, Hee Soon; Chung, Myong-Soo

    2015-03-01

    The aim of this study was to determine the heat-penetration characteristics using stationary and rotary retorts to manufacture Kimchi soup. Both heat-penetration tests and computer simulation based on mathematical modeling were performed. The sterility was measured at five different positions in the pouch. The results revealed only a small deviation of F 0 among the different positions, and the rate of heat transfer was increased by rotation of the retort. The thermal processing of retort-pouched Kimchi soup was analyzed mathematically using a finite-element model, and optimum models for predicting the time course of the temperature and F 0 were developed. The mathematical models could accurately predict the actual heat penetration of retort-pouched Kimchi soup. The average deviation of the temperature between the experimental and mathematical predicted model was 2.46% (R(2)=0.975). The changes in nodal temperature and F 0 caused by microbial inactivation in the finite-element model predicted using the NISA program were very similar to that of the experimental data of for the retorted Kimchi soup during sterilization with rotary retorts. The correlation coefficient between the simulation using the NISA program and the experimental data was very high, at 99%.

  10. Longitudinal Evaluation of Wound Healing after Penetrating Corneal Injury: Anterior Segment Optical Coherence Tomography Study.

    Science.gov (United States)

    Zheng, Kang Keng; Cai, Jianhao; Rong, Shi Song; Peng, Kun; Xia, Honghe; Jin, Chuan; Lu, Xuehui; Liu, Xinyu; Chen, Haoyu; Jhanji, Vishal

    2017-07-01

    Ocular imaging can enhance our understanding of wound healing. We report anterior segment optical coherence tomography (ASOCT) findings in penetrating corneal injury. Serial ASOCT was performed after repair of penetrating corneal injury. Internal aberrations of wound edges were labeled as "steps" or "gaps" on ASOCT images. The wound type was characterized as: type 1: continuous inner wound edge or step height ≤ 80 µm; type 2: step height > 80 µm; type 3: gap between wound edges; and type 4: intraocular tissue adherent to wound. Surgical outcomes of different wound types were compared. 50 consecutive patients were included (6 females, 44 males; mean age 33 ± 12 years). The average size of wound was 4.2 ± 2.6 mm (type 1, 8 eyes; type 2, 27 eyes; type 3, 12 eyes; type 4, 3 eyes). At the end of 3 months, 70% (n = 35) of the wounds were type 1. At the end of 6 months, all type 1 wounds had healed completely, whereas about half of type 2 (48.1%) and type 3 (50%) wounds had recovered to type 1 configuration. The wound type at baseline affected the height of step (p = 0.047) and corneal thickness at 6 months (p = 0.035). ASOCT is a useful tool for monitoring wound healing in cases with penetrating corneal injury. Majority of the wound edges appose between 3 and 6 months after trauma. In our study, baseline wound configuration affected the healing pattern.

  11. Study for the water penetration chemistry of bentonite under temperature gradation environment

    International Nuclear Information System (INIS)

    Hara, Naohiro; Imakita, Tsuyoshi

    2003-02-01

    This work have been studied for the water fluctuation in time and space in case of the ground water penetration into the unsaturated bentonite with development of the necessary test equipment. The test equipment necessary for this test, was designed on consideration of the adiabatic condition, sensors for pH, salt and water measurement. The thickness of the bentonite specimen was set to 10 cm and the temperature slope was enable to set between 80degC and 100degC at the both end of the specimen. The water for penetration was pushed by gas constant pressure up to 1 MPa. The glass electrode for pH, electric conductivity for salinity and moisture sensor for lower water content and water sensor for higher were used as the sensors. The fluctuation of salt and water in the ground water penetration test to bentonite was estimated. The sensor data were treated as parametric data, because those data could not calibrated in those high temperature and under those high bentonite swollen pressure. For another development should be needed for water sensor. (author)

  12. Analytical and experimental studies on the strain rate effects in penetration of 10wt % ballistic gelatin

    International Nuclear Information System (INIS)

    Liu, L; Jia, Z; Ma, X L; Fan, Y R

    2013-01-01

    This work concentrates on modeling the super-elastic behavior of 10wt% ballistic gelatin at 4°C and the mechanical responses at quasi-static and high-speed penetrations. Uniaxial compression and simple shearing experiments were carried out to determine the moduli in Mooney-Rivlin model describing the elastic behavior of gelatin at low strain rates. The failure mode is determined to be elastic fracture as the tensile stretch ratio exceeds a critical value. For high compression strain rates, the available results from the split Hopkinson pressure bar (SHPB) experiments for 10wt% gelatin were carefully examined and assessed. Linear relationship between the moduli and the strain rate is established. Based on these material parameters, an analytic solution of stress for the quasi-static and quasi-dynamic expansion of spherical cavity in gelatin is derived. As a consequence, the work needed to open unit volume of cavity, P s , which is the key parameter in studying penetration problems, is linearly increasing with the characteristic strain rate. The application of P s to our quasi-static and high-speed penetration experiments is discussed and assessed

  13. Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: An experimental cadaver study.

    Science.gov (United States)

    Scheele, Christian; Pietschmann, Matthias F; Schröder, Christian; Grupp, Thomas; Holderied, Melanie; Jansson, Volmar; Müller, Peter E

    2017-03-01

    Unicompartmental total knee arthroplasty (UKA) is a well-established treatment option for unicondylar osteoarthritis, and generally leads to better functional results than tricompartimental total knee arthroplasty (TKA). However, revision rates of UKAs are reported as being higher; a major reason for this is aseptic loosening of the tibial component due to implant-cement-bone interface fatigue. The objective of this study was to determine the effects of trabecular bone preparation, prior to implantation of tibial UKAs, on morphological and biomechanical outcomes in a cadaver study. Cemented UKAs were performed in 18 human cadaver knees after the bone bed was cleaned using pulsed lavage (Group A), conventional brush (Group B) or no cleaning at all (Group C, control). Morphologic cement penetration and primary stability were measured. The area proportion under the tibial component without visible cement penetration was significantly higher in Group C (21.9%, SD 11.9) than in both Group A (7.1%, SD 5.8), and Group B (6.5%, SD 4.2) (P=0.007). The overall cement penetration depth did not differ between groups. However, in the posterior part, cement penetration depth was significantly higher in Group B (1.9mm, SD 0.3) than in both Group A (1.3mm, SD 0.3) and Group C (1.4mm, SD 0.3) (P=0.015). The mode of preparation did not show a substantial effect on primary stability tested under dynamic compression-shear test conditions (P=0.910). Bone preparation significantly enhances cement interdigitation. The application of a brush shows similar results compared with the application of pulsed lavage. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Model track studies on fouled ballast using ground penetrating radar and multichannel analysis of surface wave

    Science.gov (United States)

    Anbazhagan, P.; Lijun, Su; Buddhima, Indraratna; Cholachat, Rujikiatkamjorn

    2011-08-01

    Ballast fouling is created by the breakdown of aggregates or outside contamination by coal dust from coal trains, or from soil intrusion beneath rail track. Due to ballast fouling, the conditions of rail track can be deteriorated considerably depending on the type of fouling material and the degree of fouling. So far there is no comprehensive guideline available to identify the critical degree of fouling for different types of fouling materials. This paper presents the identification of degree of fouling and types of fouling using non-destructive testing, namely seismic surface-wave and ground penetrating radar (GPR) survey. To understand this, a model rail track with different degree of fouling has been constructed in Civil engineering laboratory, University of Wollongong, Australia. Shear wave velocity obtained from seismic survey has been employed to identify the degree of fouling and types of fouling material. It is found that shear wave velocity of fouled ballast increases initially, reaches optimum fouling point (OFP), and decreases when the fouling increases. The degree of fouling corresponding after which the shear wave velocity of fouled ballast will be smaller than that of clean ballast is called the critical fouling point (CFP). Ground penetrating radar with four different ground coupled antennas (500 MHz, 800 MHz, 1.6 GHz and 2.3 GHz) was also used to identify the ballast fouling condition. It is found that the 800 MHz ground coupled antenna gives a better signal in assessing the ballast fouling condition. Seismic survey is relatively slow when compared to GPR survey however it gives quantifiable results. In contrast, GPR survey is faster and better in estimating the depth of fouling.

  15. A ten-year study of penetrating injuries of the colon.

    Science.gov (United States)

    Adesanya, Adedoyin A; Ekanem, Ekanem E

    2004-12-01

    Colon injury has been associated with a high risk of septic complications and mortality. We prospectively studied the pattern, management, outcome, and prognostic factors in patients who sustained penetrating colon injuries. Sixty patients who presented to our hospital with penetrating colon injuries over a ten-year period (1992 to 2001) were studied. Colon wounds were caused by gunshots in 55 (91.7 percent) patients and knife stabs in 5 (8.3 percent). There was a delay of more than 12 hours before laparotomy in 30 (50 percent) patients. Moderate or major fecal contamination of the peritoneal cavity occurred in 58 (96.7 percent) patients. The average penetrating abdominal trauma index score was 25.9 and 20 (33.3 percent) patients sustained Flint Grade 3 colon injury. Associated intra-abdominal injuries occurred in the small bowel (73.3 percent), liver (25 percent), stomach (23.3 percent), and mesentery (16.7 percent). Right colon wounds (35) were managed by primary repair in 24 (68.6 percent) patients and proximal diverting colostomy in 11 (31.4 percent), whereas left colon wounds (25) were managed by diverting colostomy in 22 (88.0 percent) patients and primary repair in 3 (12.0 percent) patients. Common complications included wound infection (56.7 percent), septicemia (31.7 percent), and enterocutaneous fistula (16.7 percent). The overall mortality rate was 33.3 percent and colon injury-related mortality was 21.7 percent. Presence of destructive colon injury was associated with a greater than fourfold increased incidence of death. Other significant risk factors included shock on admission, major fecal contamination, duration of operation more than four hours, penetrating abdominal trauma index score >25, and more than two postoperative complications. There was no difference in outcome between patients who had primary repair and those undergoing diverting colostomy. Colostomy closure-related morbidity was 21 percent and mortality was 5.3 percent. A more liberal

  16. Mechanistic studies of ocular peptide absorption and its enhancement by various penetration enhancers

    International Nuclear Information System (INIS)

    Rojanasakul, Y.

    1989-01-01

    Two major aspects of corneal peptide absorption, namely the transport mechanisms and the promoting effect of some penetration enhancers, were investigated. Studies on transport mechanisms involve (a) identification of transport pathways of peptides across the cornea, (b) determination of rate-limiting barrier(s) for peptide absorption, and (c) permselective properties of the cornea. To study the transport pathways of peptides, four model peptides differing in molecular size and charge were either fluorescently or radioactively labeled and their movement across the cornea was detected by laser scanning confocal microscopy and autoradiography. Results from these studies indicate that peptides can penetrate the cornea via different pathways, depending on the physicochemical properties and membrane specificity of the peptides. In all cases, the outermost layer of the corneal epithelium presents the rate-limiting barrier for peptide absorption. The results also indicate a charge discrimination effect to transport of negatively charged peptides. In permselectivity studies, it has been shown that the cornea, due to the presence of ionizable charged groups, is amphoteric and exhibits dual selective characteristics to transport of charged molecules. At pH's above the isoelectric point, 3.2, the cornea carries a net negative charge and is selective to positively-charged molecules. Below the isoelectric pH, the reverse is valid. The promoting mechanisms of penetration enhancers were studied microscopically using confocal fluorescence microscopy with the aid of a specific fluorescent membrane probe (3,3'-dioctadecyloxacarbocyanine) and a non-permeating polar tracer. All enhancers, including chelators, non-ionic surfactants, bile salts, and cytoskeleton-active agents, significantly increase membrane permeability depending on concentration and exposure time

  17. Joint application of Geoelectrical Resistivity and Ground Penetrating Radar techniques for the study of hyper-saturated zones. Case study in Egypt

    Directory of Open Access Journals (Sweden)

    Hany S. Mesbah

    2017-06-01

    Full Text Available This paper presents the results of the application of the Geoelectrical Resistivity Sounding (GRS and Ground Penetrating Radar (GPR for outlining and investigating of surface springing out (flow of groundwater to the base of an service building site, and determining the reason(s for the zone of maximum degree of saturation; in addition to provide stratigraphic information for this site. The studied economic building is constructed lower than the ground surface by about 7 m. A Vertical Electrical Sounding (VES survey was performed at 12 points around the studied building in order to investigate the vertical and lateral extent of the subsurface sequence, three VES's were conducted at each side of the building at discrete distances. And a total of 9 GPR profiles with 100- and 200-MHz antennae were conducted, with the objective of evaluating the depth and the degree of saturation of the subsurface layers. The qualitative and quantitative interpretation of the acquired VES's showed easily the levels of saturations close to and around the studied building. From the interpretation of GPR profiles, it was possible to locate and determine the saturated layers. The radar signals are penetrated and enabled the identification of the subsurface reflectors. The results of GPR and VES showed a good agreement and the integrated interpretations were supported by local geology. Finally, the new constructed geoelectrical resistivity cross-sections (in contoured-form, are easily clarifying the direction of groundwater flow toward the studied building.

  18. Experimental study of the penetrating of plates by projectile at low initial speeds

    Science.gov (United States)

    Orlov, M. Yu; Orlova, Yu N.; Smakotin, Ig L.; Glazyrin, V. P.; Orlov, Yu N.

    2017-11-01

    The research of the penetration process of lightweight plates by a projectile in the range of initial velocities up to 325 m/s was attempted. The projectile was a shell bullet and the barriers were of ice, MDF-panels and plexiglas barriers. The response of barriers to impact loading is studied. High-speed shooting of each experiment is obtained, including photos of the front and rear sides of the barriers. An attempt was made to reproduce the scenario of the destruction of barriers. The results of experiments can be interpreted only as qualitative tests. Projectile was not destroyed.

  19. Customized photorefractive keratectomy to correct high ametropia after penetrating keratoplasty: A pilot study

    OpenAIRE

    De Rosa, Giuseppe; Boccia, Rosa; Santamaria, Carmine; Fabbozzi, Lorenzo; De Rosa, Luigi; Lanza, Michele

    2014-01-01

    Purpose: To evaluate preliminarily the safety and efficacy of customized photorefractive keratectomy (PRK) to correct ametropia and irregular astigmatism after penetrating keratoplasty (PK). Methods: This pilot study included five eyes of five patients with a mean spherical equivalent of −5.1 ± 1.46 D (range from −2.75 to −6.50 D). In all cases, ametropia and irregular astigmatism was corrected with topography-guided customized PRK. Ocular examinations with topographic analysis were perfor...

  20. Ahmed glaucoma valve in post-penetrating-keratoplasty glaucoma: A critically evaluated prospective clinical study

    Science.gov (United States)

    Panda, Anita; Prakash, Vadivelu Jaya; Dada, Tanuj; Gupta, Anoop Kishore; Khokhar, Sudarshan; Vanathi, Murugesan

    2011-01-01

    Aim: The aim was to evaluate the outcome of Ahmed glaucoma valve (AGV) in post-penetrating-keratoplasty glaucoma (PKPG). Materials and Methods: In this prospective study, 20 eyes of 20 adult patients with post-PKPG with intraocular pressure (IOP) >21 mmHg, on two or more antiglaucoma medications, underwent AG (model FP7) implantation and were followed up for a minimum of 6 months. Absolute success was defined as 5 glaucoma managed by AGV implantation revealed a satisfactory outcome up to 6 months of follow-up. PMID:21586837

  1. Ground penetrating radar study of a thickness of biogenic sediments in the vicinity of the Czechowskie Lake

    Science.gov (United States)

    Lamparski, Piotr

    2014-05-01

    The paper present results of investigations, which have made on a biogenic plain in the north-east part of the vicinity of the Czechowskie Lake. The basin of Lake Czechowskie occupies a deep depression located in the immediate hinterland of the maximum range of the Pomeranian Phase ice sheet in the northern part of Poland (Błaszkiewicz 2005). Drillings carried out within the peat plain in the western part of the lake basin indicate that there are relatively diversified lake sediments of up to 12 m in thickness. The ground penetrating radar profiling method (GPR) was used to determine a thickness of biogenic sediments. To tests was used GSS'I SIR SYSTEM-2000™ radar device with two antennae - the high resolution 400 MHz central frequency - for shallow prospecting of the subsurface layers and the low resolution 35 MHz - for determining the shape of the mineral bedrock. Overall, 33 GPR profiles was made all in all more than 3000 meters along and crosswise the longer axis of the biogenic plain. The range of radar penetration was set to 200 ns for 400 MHz antenna and 600 ns for the 35 MHz one, what is the equivalent respectively 4 m and 12,5 m in depth of biogenic sediments thickness. Horizontal scaling was made by GSSI survey wheel device. The thickness of biogenic sediments recognized by GPR reaches 10 meters only using 35 MHz antenna. In the case of the 400 MHz antenna, relatively high conductivity water-saturated peat and gyttia did not allow for the achievement of greater thickness than 3-4 meters testing. In a large part of the profiles was able to see the shape of the mineral bedrock in the form of a former lake basin. Also observed elevations and thresholds in the bedrock. Depth of the mineral deposits forming former lake bottom was confirmed by drillings. This study is a contribution to the Virtual Institute of Integrated Climate and Landscape Evolution Analysis -ICLEA- of the Helmholtz Association. References: Błaszkiewicz M, 2005. Późnoglacjalna i

  2. A simulation study of impulsive penetration of solar wind irregularities into the magnetosphere at the dayside magnetopause

    International Nuclear Information System (INIS)

    Ma, Z.W.; Hawkins, J.G.; Lee, L.C.

    1991-01-01

    A two-dimensional magnetohydrodynamic code is used to study impulsive penetration processes that occur when a plasma irregularity in the magnetosheath, modeled as a field-aligned filament, impinges on the dayside magnetopause. If the magnetic fields in the magnetosheath and magnetosphere are parallel or antiparallel, then a filament in the magnetosheath can always penetrate into the magnetosphere. However, if the fields in the magnetosheath and magnetosphere are not aligned, then a filament can only penetrate into the magnetosphere when its initial kinetic energy density exceeds the magnetic energy density attributed to the transverse component of the magnetic field by a factor of 50. In this case, the magnetospheric field lines reconnect behind the filament, thereby trapping it within the magnetosphere. Otherwise, the increasing magnetic stress in front of the filament will eventually stop the filament from further penetration. For typical parameters found at the dayside magnetopause, the threshold condition obtained from this two-dimensional model predicts that penetration is possible only when the angle between the fields is within approximately 5 of parallel or antiparallel. During the penetration process, velocity vortices are observed both inside the filament and in the external plasma. Either increased β within the magnetosphere, or the larger plasma density at the magnetopause associated with antiparallel magnetic fields, will act to reduce the penetration velocity

  3. Localization of dexamethasone within dendritic core-multishell (CMS) nanoparticles and skin penetration properties studied by multi-frequency electron paramagnetic resonance (EPR) spectroscopy.

    Science.gov (United States)

    Saeidpour, S; Lohan, S B; Anske, M; Unbehauen, M; Fleige, E; Haag, R; Meinke, M C; Bittl, R; Teutloff, C

    2017-07-01

    The skin and especially the stratum corneum (SC) act as a barrier and protect epidermal cells and thus the whole body against xenobiotica of the external environment. Topical skin treatment requires an efficient drug delivery system (DDS). Polymer-based nanocarriers represent novel transport vehicles for dermal application of drugs. In this study dendritic core-multishell (CMS) nanoparticles were investigated as promising candidates. CMS nanoparticles were loaded with a drug (analogue) and were applied to penetration studies of skin. We determined by dual-frequency electron paramagnetic resonance (EPR) how dexamethasone (Dx) labelled with 3-carboxy-2,2,5,5-tetramethyl-1-pyrrolidinyloxy (PCA) is associated with the CMS. The micro-environment of the drug loaded to CMS nanoparticles was investigated by pulsed high-field EPR at cryogenic temperature, making use of the fact that magnetic parameters (g-, A-matrices, and spin-lattice relaxation time) represent specific probes for the micro-environment. Additionally, the rotational correlation time of spin-labelled Dx was probed by continuous wave EPR at ambient temperature, which provides independent information on the drug environment. Furthermore, the penetration depth of Dx into the stratum corneum of porcine skin after different topical applications was investigated. The location of Dx in the CMS nanoparticles is revealed and the function of CMS as penetration enhancers for topical application is shown. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Experimental study on the penetration effect of ceramics composite projectile on ceramic / A3 steel compound targets

    Directory of Open Access Journals (Sweden)

    Di-qi Hu

    2017-08-01

    Full Text Available In order to improve the penetration of projectiles into ceramic composite armors, the nose of 30 mm standard projectile was replaced by a toughened ceramic nose, and the performance of ceramic-nose projectiles penetrating into ceramic/A3 steel composite targets has been experimentally researched. According to impact dynamics theory,, the performances of 30 mm ceramic-nose projectile and 30 mm standard projectile penetrating into the ceramic/A3 steel composite targets were analyzed and compared using DOP method, especially focusing on the effects made by different nose structures and materials. The aperture and depth of perforation of projectile into the armor plates as well as the residual mass of bullet core under the same conditions were comparatively analyzed. A numerical simulation was built and computed by ANSYS/LS-DYNA. Based on the simulated results, the penetration performance was further analyzed in terms of the residual mass of bullet core. The results show that the ceramic nose has a great effect on the protection of bullet core.

  5. Renewable Electricity Futures Study. Volume 1. Exploration of High-Penetration Renewable Electricity Futures

    Energy Technology Data Exchange (ETDEWEB)

    Hand, M. M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Baldwin, S. [U.S. Dept. of Energy, Washington, DC (United States); DeMeo, E. [Renewable Energy Consulting, Chicago, IL (United States); Reilly, J. M. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Mai, T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arent, D. [Joint Inst. for Strategic Energy Analysis, Boulder, CO (United States); Porro, G. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Meshek, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sandor, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-06-15

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%–90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT). Learn more at the RE Futures website. http://www.nrel.gov/analysis/re_futures/

  6. Renewable Electricity Futures Study. Volume 1: Exploration of High-Penetration Renewable Electricity Futures

    Energy Technology Data Exchange (ETDEWEB)

    Mai, T.; Wiser, R.; Sandor, D.; Brinkman, G.; Heath, G.; Denholm, P.; Hostick, D.J.; Darghouth, N.; Schlosser, A.; Strzepek, K.

    2012-06-01

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%-90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT).

  7. Study of total column atmospheric aerosol optical depth, ozone and ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    general circulation models. ... at all wavelengths from initial to later part of observation period due to cloud-scavenging and rain-washout effects as well as signature of coastal aerosol loading. ... important roles in the study of the Earth's climate.

  8. Spectrometric kidney depth measurement method

    International Nuclear Information System (INIS)

    George, P.; Soussaline, F.; Raynaud, C.

    1976-01-01

    The method proposed uses the single posterior surface measurement of the kidney radioactivity distribution. The ratio C/P of the number of scattered photons to the number of primary photons, which is a function of the tissue depth penetrated, is calculated for a given region. The parameters on which the C/P value depends are determined from studies on phantoms. On the basis of these results the kidney depth was measured on a series of 13 patients and a correlation was established between the value thus calculated and that obtained by the profile method. The reproducibility of the method is satisfactory [fr

  9. Longitudinal Study of the Market Penetration of Cockpit Weather Information Systems

    Science.gov (United States)

    Stough, Harry Paul, III; Sireli, Yesim; Ozan, Erol; Kauffmann, Paul

    2005-01-01

    The purpose of the longitudinal research of the market penetration of cockpit weather information systems (CWIS) is to contribute to the body of knowledge on modeling advanced technology feasibility in aviation by tracking and analyzing the market adoption of CWIS over a three year period. This research takes advantage of a previous study, conducted by Dr. Paul Kauffmann in 2000, which demonstrated an integrated and cost effective approach to evaluate advanced technology feasibility, examining the feasibility of CWIS in five market segments: transport, commuter, general aviation, business, and rotorcraft. The longitudinal research consists of two consecutive studies and produced two reports. The first report was submitted in August 2003 and included general market analysis about the CWIS products in the market at the time, identified their characteristics and examined developing market dynamics.

  10. Erratum to: Study on Chloride Ion Penetration Resistance of Rubberized Concrete Under Steady State Condition

    Directory of Open Access Journals (Sweden)

    Md Noor Nurazuwa

    2016-01-01

    In this paper, the effect of crumb rubber, CR as fine aggregate in the concrete to enhance concrete durability against chloride ion diffusion was studied. Chloride ion diffusion in rubberized concrete was tested by migration test under steady state condition. Concrete specimen with water-to-cement ratio of 0.50 was prepared to study the CR effectiveness in comparison with lower water-to-cement ratio. In addition, 10% silica fume, SF was added to provide denser concrete and to understand its effectiveness against chloride ion diffusion. Results showed that chloride transport characteristics were improved by the increasing amount of CR in all mixed due to the fact that CR has the ability to repel water. Meanwhile, rubberized concrete with w/c = 0.35 gave better resistance against chloride ion penetration compared to w/c = 0.50. This was much improved with combination of CR and SF.

  11. Pig and guinea pig skin as surrogates for human in vitro penetration studies: a quantitative review.

    Science.gov (United States)

    Barbero, Ana M; Frasch, H Frederick

    2009-02-01

    Both human and animal skin in vitro models are used to predict percutaneous penetration in humans. The objective of this review is a quantitative comparison of permeability and lag time measurements between human and animal skin, including an evaluation of the intra and inter species variability. We limit our focus to domestic pig and rodent guinea pig skin as surrogates for human skin, and consider only studies in which both animal and human penetration of a given chemical were measured jointly in the same lab. When the in vitro permeability of pig and human skin were compared, the Pearson product moment correlation coefficient (r) was 0.88 (Ppig and 35% for human, and an inter species average coefficient of variation of 37% for the set of studied compounds (n=41). The lag times of pig skin and human skin did not correlate (r=0.35, P=0.26). When the in vitro permeability of guinea pig and human skin were compared, r=0.96 (Pguinea pig and 24% for human, and an inter species coefficient of variation of permeability of 41% for the set of studied compounds (n=15). Lag times of guinea pig and human skin correlated (r=0.90, Ppig skin (n=50) and guinea pig skin (n=25). For pig skin, 80% of measurements fell within the range 0.3guinea pig skin, 65% fell within that range. Both pig and guinea pig are good models for human skin permeability and have less variability than the human skin model. The skin model of choice will depend on the final purpose of the study and the compound under investigation.

  12. STUDY OF THE ANATOMICAL AND VISUAL RESULTS OF THERAPEUTIC PENETRATING KERATOPLASTY

    Directory of Open Access Journals (Sweden)

    Chhaya Ashok Shinde

    2017-03-01

    Full Text Available BACKGROUND Therapeutic penetrating keratoplasty for corneal infections restores anatomical integrity. Improvement in instrumentation and surgical techniques, better postoperative management have improved corneal transplant outcome. Purpose of the study was to know what are the anatomical and visual results after therapeutic keratoplasty and to judge what could be the factors affecting the results. MATERIALS AND METHODS Prospective, non-comparative, observational cohort study was done in 56 patient (56 eyes operated for therapeutic penetrating keratoplasty at tertiary care institute .Patients were reviewed for demographic data, postoperative best-corrected visual acuity, graft clarity, and complications. Pre-operative treatment in bacterial infections included Cefazolin 50 mg/ml and Tobramycin 1.4 % or gentamicin 1.4% half hourly, 1% atropine drops. Fungal infections were treated with Natamycin 5% suspension. Debridement was done. Amphotericin B was used against yeasts. Voriconazole (1% eye drops were given in Aspergillus species. With full aseptic precautions penetrating keratoplasty was carried out. The graft was 0.5 mm larger than the lesion. Keratoplasties were evaluated for (1 Graft clarity at 1 month and 1 year postoperative. (2 Cure of the infectious disease after surgery. (3 Anatomical success rate and visual results. RESULTS At the end of one year clear graft with bacterial keratitis was seen in 23 eyes (74.19% out of 31 eyes. In fungal keratitis clear graft was seen in 10 eyes (45.45% out of 22 eyes. 48.22% patients had vision of FC 1m-6/60 compared to preoperative vision at the end of one year. At the end of one year anatomical integrity was maintained in 53 (94.64% cases and it was lost in 5.36% patients. CONCLUSION Patients who underwent keratoplasty with 7.5 mm graft size had maximum graft clarity at the end of one year. Graft was clear in 36 patients (64.29% out of total 56 patients. At the end of 1 year vision improved to FC 1 mt

  13. Study liquid length penetration results obtained with a direct acting piezo electric injector

    International Nuclear Information System (INIS)

    Payri, Raul; Gimeno, Jaime; Bardi, Michele; Plazas, Alejandro H.

    2013-01-01

    Highlights: ► A direct acting injector capable of controlling needle lift has been used to determine liquid phase penetration. ► The influence of injection pressure, chamber density and chamber temperature have been measured. ► When needle lift is reduced the stabilized liquid length is shortened. ► The relationship between needle lift and liquid length makes needle lift as a new way to control the injection event. - Abstract: A state of the art prototype common rail injector featuring direct control of the needle by means of a piezo stack (direct acting) has been tested. Liquid phase penetration of the sprays in diesel engine-like conditions has been studied via imaging technique in a novel continuous flow test chamber that allows an accurate control on a wide range of thermodynamic conditions (up to 1000 K and 15 MPa). This state of the art injector fitted with a 7-hole nozzle, allows a fully flexible control on the nozzle needle movement, enabling various fuel injection rate typologies. The temporal evolution of the seven sprays has been studied recording movies of the injection event in evaporative conditions via Mie scattering imaging technique and using a high speed camera. The results showed a strong influence of needle position on the stabilized liquid length while the effect of the injection pressure is negligible: the decrease of the needle lift causes a pressure drop in the needle seat and thus a reduction in the effective pressure upstream of the orifices (in the nozzle sac). According to known literature the stabilized liquid-length depends mainly on effective diameter, spray cone-angle and fuel/air properties and does not depend on fuel velocity at the orifice outlet. Therefore, due to small change in the spray cone-angle, higher injection pressures give slightly lower liquid length. However, partial needle lifts has an opposite effect: when needle is partially lifted a dramatic increase of the spray cone-angle and a consequent reduction of

  14. Ink Penetration of Uncoated Inkjet Paper and Impact on Printing Quality

    Directory of Open Access Journals (Sweden)

    Ren'ai Li

    2015-10-01

    Full Text Available This study investigated ink penetration through imaging technology, first by gray and contour mapping and then calculating the ink penetration depth by programing. Next, a series of further analyses were carried out, including average ink permeability, ink distributions, and printability of different uncoated inkjet paper with different parameters. The impact on ink penetration of the microstructure and hydrophilicity of the uncoated paper was also studied. The experimental results indicated that paper specimens with sizing agent were resistant to the ink, resulting in a slow and shallow ink penetration. Paper containing filler had a more hydrophilic surface and porous structure, leading to a faster and deeper ink penetration. However, the calendering operation could make the paper structure more compact and reduce the porosity and penetration depth. When an appropriate combination of sizing agent, filler content, and the calendering process was utilized, a more stable hue could be produced with improvements in optical density, saturation, and color.

  15. The oxygen-isotope effect on the in-plane penetration depth in underdoped Y{sub 1-x} Pr{sub x} Ba{sub 2} Cu{sub 3} O{sub 7-{delta}} as revealed by muon-spin rotation

    Energy Technology Data Exchange (ETDEWEB)

    Khasanov, R [Physik-Institut der Universitaet Zuerich, CH-8057 Zurich (Switzerland); Shengelaya, A [Physik-Institut der Universitaet Zuerich, CH-8057 Zurich (Switzerland); Conder, K [Laboratory for Neutron Scattering, ETH Zuerich and PSI Villigen, CH-5232 Villigen PSI (Switzerland); Morenzoni, E [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Savic, I M [Faculty of Physics, University of Belgrade, 11001 Belgrade (Yugoslavia); Keller, H [Physik-Institut der Universitaet Zuerich, CH-8057 Zurich (Switzerland)

    2003-01-22

    The oxygen-isotope ({sup 16}O/{sup 18}O) effect (OIE) on the in-plane penetration depth {lambda}{sub ab} (0) in underdoped Y{sub 1-x} Pr{sub x} Ba{sub 2} Cu{sub 3} O{sub 7-{delta}} was studied by means of muon-spin rotation. A pronounced OIE on {lambda}{sub ab}{sup -2} (0) was observed with a relative isotope shift of {delta}{lambda}{sub ab}{sup -2} /{lambda} {sub ab}{sup -2} = -5(2)% for x=0.3 and -9(2)% for x=0.4. The OIE exponents of T{sub c} and of {lambda}{sub ab}{sup -2} (0) exhibit a relation that appears to be generic for cuprate superconductors. (letter to the editor)

  16. Low Force Penetration of Icy Regolith

    Science.gov (United States)

    Mantovani, J. G.; Galloway, G. M.; Zacny, K.

    2016-01-01

    A percussive cone penetrometer measures the strength of granular material by using percussion to deliver mechanical energy into the material. A percussive cone penetrometer was used in this study to penetrate a regolith ice mixture by breaking up ice and decompacting the regolith. As compared to a static cone penetrometer, percussion allows low reaction forces to push a penetrometer probe tip more easily into dry regolith in a low gravity environment from a planetary surface rover or a landed spacecraft. A percussive cone penetrates icy regolith at ice concentrations that a static cone cannot penetrate. In this study, the percussive penetrator was able to penetrate material under 65 N of down-force which could not be penetrated using a static cone under full body weight. This paper discusses using a percussive cone penetrometer to discern changes in the concentration of water-ice in a mixture of lunar regolith simulant and ice to a depth of one meter. The rate of penetration was found to be a function of the ice content and was not significantly affected by the down-force. The test results demonstrate that this method may be ideal for a small platform in a reduced gravity environment. However, there are some cases where the system may not be able to penetrate the icy regolith, and there is some risk of the probe tip becoming stuck so that it cannot be retracted. It is also shown that a percussive cone penetrometer could be used to prospect for water ice in regolith at concentrations as high as 8 by weight.

  17. Potential of Probing the Lunar Regolith using Rover-Mounted Ground Penetrating Radar: Moses Lake Dune Field Analog Study

    Science.gov (United States)

    Horz, F.; Heggy, E.; Fong, T.; Kring, D.; Deans, M.; Anglade, A.; Mahiouz, K.; Bualat, M.; Lee, P.; Bluethmann, W.

    2009-01-01

    Probing radars have been widely recognized by the science community to be an efficient tool to explore lunar subsurface providing a unique capability to address several scientific and operational issues. A wideband (200 to 1200 MHz) Ground Penetrating Radar (GPR) mounted on a surface rover can provide high vertical resolution and probing depth from few tens of centimeters to few tens of meters depending on the sounding frequency and the ground conductivity. This in term can provide a better understand regolith thickness, elemental iron concentration (including ilmenite), volatile presence, structural anomalies and fracturing. All those objectives are of important significance for understanding the local geology and potential sustainable resources for future landing sites in particular exploring the thickness, structural heterogeneity and potential volatiles presence in the lunar regolith. While the operation and data collection of GPR is a straightforward case for most terrestrial surveys, it is a challenging task for remote planetary study especially on robotic platforms due to the complexity of remote operation in rough terrains and the data collection constrains imposed by the mechanical motion of the rover and limitation in data transfer. Nevertheless, Rover mounted GPR can be of great support to perform systematic subsurface surveys for a given landing site as it can provide scientific and operational support in exploring subsurface resources and sample collections which can increase the efficiency of the EVA activities for potential human crews as part of the NASA Constellation Program. In this study we attempt to explore the operational challenges and their impact on the EVA scientific return for operating a rover mounted GPR in support of potential human activity on the moon. In this first field study, we mainly focused on the ability of GPR to support subsurface sample collection and explore shallow subsurface volatiles.

  18. Improving 6061-Al Grain Growth and Penetration across HIP-Bonded Clad Interfaces in Monolithic Fuel Plates: Initial Studies

    Energy Technology Data Exchange (ETDEWEB)

    Hackenberg, Robert E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McCabe, Rodney J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Montalvo, Joel D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Clarke, Kester D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Edwards, Randall L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Crapps, Justin M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Trujillo, R. Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Aikin, Beverly [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Vargas, Victor D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hollis, Kendall J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lienert, Thomas J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Forsyth, Robert T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Harada, Kiichi L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2013-05-06

    Grain penetration across aluminum-aluminum cladding interfaces in research reactor fuel plates is desirable and was obtained by a legacy roll-bonding process, which attained 20-80% grain penetration. Significant grain penetration in monolithic fuel plates produced by Hot Isostatic Press (HIP) fabrication processing is equally desirable but has yet to be attained. The goal of this study was to modify the 6061-Al in such a way as to promote a much greater extent of crossinterface grain penetration in monolithic fuel plates fabricated by the HIP process. This study documents the outcomes of several strategies attempted to attain this goal. The grain response was characterized using light optical microscopy (LOM) electron backscatter diffraction (EBSD) as a function of these prospective process modifications done to the aluminum prior to the HIP cycle. The strategies included (1) adding macroscopic gaps in the sandwiches to enhance Al flow, (2) adding engineering asperities to enhance Al flow, (3) adding stored energy (cold work), and (4) alternative cleaning and coating. Additionally, two aqueous cleaning methods were compared as baseline control conditions. The results of the preliminary scoping studies in all the categories are presented. In general, none of these approaches were able to obtain >10% grain penetration. Recommended future work includes further development of macroscopic grooving, transferred-arc cleaning, and combinations of these with one another and with other processes.

  19. Palaeoecological studies as a source of peat depth data: A discussion and data compilation for Scotland

    Directory of Open Access Journals (Sweden)

    J. Ratcliffe

    2016-06-01

    Full Text Available The regional/national carbon (C stock of peatlands is often poorly characterised, even for comparatively well-studied areas. A key obstacle to better estimates of landscape C stock is the scarcity of data on peat depth, leading to simplistic assumptions. New measurements of peat depth become unrealistically resource-intensive when considering large areas. Therefore, it is imperative to maximise the use of pre-existing datasets. Here we propose that one potentially valuable and currently unexploited source of peat depth data is palaeoecological studies. We discuss the value of these data and present an initial compilation for Scotland (United Kingdom which consists of records from 437 sites and yields an average depth of 282 cm per site. This figure is likely to be an over-estimate of true average peat depth and is greater than figures used in current estimates of peatland C stock. Depth data from palaeoecological studies have the advantages of wide distribution, high quality, and often the inclusion of valuable supporting information; but also the disadvantage of spatial bias due to the differing motivations of the original researchers. When combined with other data sources, each with its own advantages and limitations, we believe that palaeoecological datasets can make an important contribution to better-constrained estimates of peat depth which, in turn, will lead to better estimates of peatland landscape carbon stock.

  20. Depth-based human activity recognition: A comparative perspective study on feature extraction

    Directory of Open Access Journals (Sweden)

    Heba Hamdy Ali

    2018-06-01

    Full Text Available Depth Maps-based Human Activity Recognition is the process of categorizing depth sequences with a particular activity. In this problem, some applications represent robust solutions in domains such as surveillance system, computer vision applications, and video retrieval systems. The task is challenging due to variations inside one class and distinguishes between activities of various classes and video recording settings. In this study, we introduce a detailed study of current advances in the depth maps-based image representations and feature extraction process. Moreover, we discuss the state of art datasets and subsequent classification procedure. Also, a comparative study of some of the more popular depth-map approaches has provided in greater detail. The proposed methods are evaluated on three depth-based datasets “MSR Action 3D”, “MSR Hand Gesture”, and “MSR Daily Activity 3D”. Experimental results achieved 100%, 95.83%, and 96.55% respectively. While combining depth and color features on “RGBD-HuDaAct” Dataset, achieved 89.1%. Keywords: Activity recognition, Depth, Feature extraction, Video, Human body detection, Hand gesture

  1. Use of Ground Penetrating Radar for Locating Contraband Aboard Ocean Going Vessels: Feasibility Study

    National Research Council Canada - National Science Library

    Llopis, Jose

    2001-01-01

    Ground Penetrating Radar (GPR) surveys were conducted over various stockpiled materials at the Alabama state Docks located in Mobile, AL, to determine whether GPR is a viable method for rapidly detecting contraband materials...

  2. Modified Standard Penetration Test–based Drilled Shaft Design Method for Weak Rocks (Phase 2 Study)

    Science.gov (United States)

    2017-12-15

    In this project, Illinois-specific design procedures were developed for drilled shafts founded in weak shale or rock. In particular, a modified standard penetration test was developed and verified to characterize the in situ condition of weak shales ...

  3. Numerical and Experimental Study on the Formation and Dispersion Patterns of Multiple Explosively Formed Penetrators

    Directory of Open Access Journals (Sweden)

    Jian Feng Liu

    Full Text Available Abstract Three-dimensional numerical simulations and experiments were performed to examine the formation and spatial dispersion patterns of integral multiple explosively formed penetrators (MEFP warhead with seven hemispherical liners. Numerical results had successfully described the formation process and distribution pattern of MEFP. A group of penetrators consisting of a central penetrator surrounded by 6 penetrators is formed during the formation process of MEFP and moves in the direction of aiming position. The maximum divergence angle of the surrounding penetrator group was 7.8°, and the damage area could reach 0.16 m2 at 1.2 m. The laws of perforation dispersion patterns of MEFP were also obtained through a nonlinear fitting of the perforation information on the target at different standoffs. The terminal effects of the MEFP warhead were performed on three #45 steel targets with a dimension of 160cm ( 160cm ( 1.5cm at various standoffs (60, 80, and 120 cm. The simulation results were validated through penetration experiments at different standoffs. It has shown excellent agreement between simulation and experiment results.

  4. Simulation for ground penetrating radar (GPR) study of the subsurface structure of the Moon

    Science.gov (United States)

    Fa, Wenzhe

    2013-12-01

    Ground penetrating radar (GPR) is currently within the scope of China's Chang-E 3 lunar mission, to study the shallow subsurface of the Moon. In this study, key factors that could affect a lunar GPR performance, such as frequency, range resolution, and antenna directivity, are discussed firstly. Geometrical optics and ray tracing techniques are used to model GPR echoes, considering the transmission, attenuation, reflection, geometrical spreading of radar waves, and the antenna directivity. The influence on A-scope GPR echoes and on the simulated radargrams for the Sinus Iridum region by surface and subsurface roughness, dielectric loss of the lunar regolith, radar frequency and bandwidth, and the distance between the transmit and receive antennas are discussed. Finally, potential scientific return about lunar subsurface properties from GPR echoes is also discussed. Simulation results suggest that subsurface structure from several to hundreds of meters can be studied from GPR echoes at P and VHF bands, and information about dielectric permittivity and thickness of subsurface layers can be estimated from GPR echoes in combination with regolith composition data.

  5. Sodium lauryl sulfate enhances nickel penetration through guinea-pig skin. Studies with energy dispersive X-ray microanalysis

    International Nuclear Information System (INIS)

    Lindberg, M.; Sagstroem, S.R.; Roomans, G.M.; Forslind, B.

    1989-01-01

    The effect of sodium lauryl sulphate (SLS), a common ingredient of detergents, on the penetration of nickel through the stratum corneum in the guinea-pig skin model was studied with energy dispersive X-ray microanalysis (EDX) to evaluate the barrier-damaging properties of this common detergent. The EDX technique allows a simultaneous determination of physiologically important elements, e.g., Na, Mg, P, Cl, K, Ca and S in addition to Ni at each point of measurement in epidermal cell strata. Our results show that SLS reduces the barrier function to Ni-ion penetration of the stratum corneum. In addition we have shown that EDX allows analysis of the influence of different factors involved in nickel penetration through the skin by giving data on the physiological effects on the epidermal cells caused by the applied substances

  6. Changes in the Economic Value of Variable Generation at High Penetration Levels: A Pilot Case Study of California

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Andrew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wiser, Ryan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-05-18

    We estimate the long-run economic value of variable renewable generation with increasing penetration using a unique investment and dispatch model that captures long-run investment decisions while also incorporating detailed operational constraints and hourly time resolution over a full year. High time resolution and the incorporation of operational constraints are important for estimating the economic value of variable generation, as is the use of a modeling framework that accommodates new investment decisions. The model is herein applied with a case study that is loosely based on California in 2030. Increasing amounts of wind, photovoltaics (PV), and concentrating solar power (CSP) with and without thermal energy storage (TES) are added one at a time. The marginal economic value of these renewable energy sources is estimated and then decomposed into capacity value, energy value, day-ahead forecast error cost, and ancillary services. The marginal economic value, as defined here, is primarily based on the combination of avoided capital investment cost and avoided variable fuel and operations and maintenance costs from other power plants in the power system. Though the model only captures a subset of the benefits and costs of renewable energy, it nonetheless provides unique insights into how the value of that subset changes with technology and penetration level. Specifically, in this case study implementation of the model, the marginal economic value of all three solar options is found to exceed the value of a flat-block of power (as well as wind energy) by \\$20--30/MWh at low penetration levels, largely due to the high capacity value of solar at low penetration. Because the value of CSP per unit of energy is found to be high with or without thermal energy storage at low penetration, we find little apparent incremental value to thermal storage at low solar penetration in the present case study analysis. The marginal economic value of PV and CSP without thermal

  7. Periodontal Pocket Depth, Hyperglycemia, and Progression of Chronic Kidney Disease: A Population-Based Longitudinal Study.

    Science.gov (United States)

    Chang, Jia-Feng; Yeh, Jih-Chen; Chiu, Ya-Lin; Liou, Jian-Chiun; Hsiung, Jing-Ru; Tung, Tao-Hsin

    2017-01-01

    No large epidemiological study has been conducted to investigate the interaction and joint effects of periodontal pocket depth and hyperglycemia on progression of chronic kidney disease in patients with periodontal diseases. Periodontal pocket depth was utilized for the grading severity of periodontal disease in 2831 patients from January 2002 to June 2013. Progression of chronic kidney disease was defined as progression of color intensity in glomerular filtration rate and albuminuria grid of updated Kidney Disease-Improving Global Outcomes guidelines. Multivariable-adjusted hazard ratios (aHR) in various models were presented across different levels of periodontal pocket depth and hemoglobin A1c (HbA1c) in forest plots and 3-dimensional histograms. During 7621 person-years of follow-up, periodontal pocket depth and HbA1C levels were robustly associated with incremental risks for progression of chronic kidney disease (aHR 3.1; 95% confidence interval [CI], 2.0-4.6 for periodontal pocket depth >4.5 mm, and 2.5; 95% CI, 1.1-5.4 for HbA1C >6.5%, respectively). The interaction between periodontal pocket depth and HbA1C on progression of chronic kidney disease was strong (P periodontal pocket depth (>4.5 mm) and higher HbA1C (>6.5%) had the greatest risk (aHR 4.2; 95% CI, 1.7-6.8) compared with the lowest aHR group (periodontal pocket depth ≤3.8 mm and HbA1C ≤6%). Our study identified combined periodontal pocket depth and HbA1C as a valuable predictor of progression of chronic kidney disease in patients with periodontal diseases. While considering the interaction between periodontal diseases and hyperglycemia, periodontal survey and optimizing glycemic control are warranted to minimize the risk of worsening renal function. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Enhanced skin penetration of lidocaine through encapsulation into nanoethosomes and nanostructured lipid carriers: a comparative study.

    Science.gov (United States)

    Babaei, S; Ghanbarzadeh, S; Adib, Z M; Kouhsoltani, M; Davaran, S; Hamishehkar, H

    2016-05-01

    Lipid based nanoparticles have become a major research object in topical drug delivery to enable drugs to pass the stratum corneum and reach the desired skin layer. The present investigation deals with the encapsulation of lidoacine into nanostructured lipid carriers (NLCs) and nanoethosomes for improving its dermal delivery and consequently local anesthetic efficacy. Concurrently these two topical delivery systems were compared. Lidocaine-loaded NLCs and nanoethosomes were characterized by various techniques and used for an in vitro skin penetration study using excised rat skin and Franz diffusion cells. The nanoparticles were tracked in the skin by following the Rhodamine-labled nanocarriers under fluorescent microscopy. Optimized lidocaine-loaded NLCs (size 96 nm, zeta potential -13.7 mV, encapsulation efficiency (EE) % 69.86% and loading capacity (LC) % 10.47%) and nanoethosomes (size 105.4 nm, zeta potential -33.6 mV, EE 40.14% and LC 8.02%) were chosen for a skin drug delivery study. Higher skin drug deposition of NLCs and nanoethosomal formulations compared to lidocaine hydroalcoholic solution represented a better localization of the drug in the skin. NLC formulation showed the lowest entered drug in the receptor phase of Franz diffusion cell in comparison with nanoethosomes and hydroalcoholic solution confirming the highest skin accumulation of drug. Both colloidal systems showed superiority over the drug solution for dermal delivery of lidocaine, however, NLC exhibited more promising characteristics than nanoethosomes regarding drug loading and skin targeted delivery.

  9. Birch pollen influence the severity of atopic eczema – prospective clinical cohort pilot study and ex vivo penetration study

    Directory of Open Access Journals (Sweden)

    Fölster-Holst R

    2015-10-01

    Full Text Available Regina Fölster-Holst,1 Jagoda Galecka,1 Sigo Weißmantel,1 Ute Dickschat,2 Frank Rippke,3 Kerstin Bohnsack,3 Thomas Werfel,4 Katja Wichmann,4 Matthias Buchner,1 Thomas Schwarz,1 Annika Vogt,5 Jürgen Lademann,5 Martina C Meinke5 1Department of Dermatology, Venerology and Allergy, University of Kiel, 2Wörth, 3Beiersdorf AG, Hamburg, 4Department of Dermatology, Venerology and Allergy, Division of Immunodermatology and Allergy Research, Hannover Medical School, Hannover, 5Department of Dermatology, Venerology and Allergology, Charité – Universitätsmedizin Berlin, Berlin, Germany Abstract: There is little clinical evidence for a correlation between the severity of atopic eczema (AE and pollen exposition. To obtain more data, we performed a clinical cohort pilot study about the influence of pollen on AE between sensitized and nonsensitized subjects and an experimental study addressing the cutaneous penetration of pollen into the skin. Fifty-five patients were monitored during birch pollen season. To study the cutaneous penetration, grass pollen allergens were applied on excised skin and the uptake in CD1c-expressing dendritic cells was investigated. The correlation between environmental pollen load and severity of the Scoring Atopic Dermatitis (SCORAD score and pruritus was observed, regardless of the status of sensitization. The sensitized group recovered significantly worse after the birch pollen season. Remarkably higher amounts of pollen allergens taken up by CD1c cells were detected in epidermal cells derived from skin explants with a disturbed epidermal barrier. These findings suggest an exacerbating role of pollen in AE utilizing the epidermal route. Keywords: aeroallergens, atopic eczema, seasonality, skin antigen-presenting cells, skin barrier penetration

  10. Interactions of skin thickness and physicochemical properties of test compounds in percutaneous penetration studies

    DEFF Research Database (Denmark)

    Wilkinson, Simon C.; Maas, Wilfred J. M.; Nielsen, Jesper Bo

    2006-01-01

    : Percutaneous penetration of caffeine (log P -0.01), testosterone (log P 3.32), propoxur (log P 1.52) (finite dose in ethanol to water vehicle ratio) and butoxyethanol (log P 0.83) (undiluted finite dose or as an infinite dose 50% [v/v] aqueous solution) through skin of varying thicknesses under occluded...... conditions was measured using flow through cells for 8-24 h. Saline (adjusted to pH 7.4) was used as receptor fluid, with BSA added for studies with testosterone and propoxur. Following exposure, the remaining surface dose was removed by swabbing and the skin digested prior to scintillation counting. Results......: The maximum flux of caffeine was increased with decreasing skin thickness, although these differences were found to be non-significant. The presence of caffeine in the skin membrane was not altered by skin thickness. Maximum flux and cumulative dose absorbed of testosterone and butoxyethanol (in both finite...

  11. Ahmed glaucoma valve in post-penetrating-keratoplasty glaucoma: A critically evaluated prospective clinical study

    Directory of Open Access Journals (Sweden)

    Anita Panda

    2011-01-01

    Full Text Available Aim: The aim was to evaluate the outcome of Ahmed glaucoma valve (AGV in post-penetrating-keratoplasty glaucoma (PKPG. Materials and Methods: In this prospective study, 20 eyes of 20 adult patients with post-PKPG with intraocular pressure (IOP >21 mmHg, on two or more antiglaucoma medications, underwent AG (model FP7 implantation and were followed up for a minimum of 6 months. Absolute success was defined as 5 < IOP < 21 mmHg and qualified success as 5 < IOP < 21 mmHg with medications or minor procedures. Results: The mean IOP decreased from 42.95 ± 10.24 to 17.69 ± 3.64 mmHg (P < 0.001 and the use of medications dropped from 2.92 to 0.39 (P < 0.001 after AGV implantation. The absolute success was achieved in 11 eyes and qualified success in 9. There was no significant change in best corrected visual acuity, graft clarity, or graft thickness. Six device-related complications occurred after AGV implantations which were successfully managed with medical or minor surgical therapy. Conclusions: Postkeratoplasty refractory glaucoma managed by AGV implantation revealed a satisfactory outcome up to 6 months of follow-up.

  12. Study of time variation of terrestrial gamma radiation due to depth distribution of soil moisture content

    International Nuclear Information System (INIS)

    Yoshioka, Katsuhiro

    1994-01-01

    An empirical equation was deduced from studies of time variations of terrestrial gamma exposure rate and soil moisture content with depth distribution in the surface layer. It was definitely suggested that the variation of terrestrial gamma exposure rate is most strongly influenced by the change of soil moisture content at 5 cm depth. The seasonal variation with a relative maximum in early autumn and a relative minimum in early spring was clearly obtained in the consequence of long time measurements of terrestrial gamma exposure rate and degree of soil dryness. The diurnal change and phase difference due to the effect of depth were also obtained in the dynamic characteristics of soil moisture content at 3 different depths. From the comparison between measured terrestrial gamma exposure rate and that evaluated from soil moisture content using the empirical equation, it was seen that seasonal variations of the both agreed fairly well as a whole. (author)

  13. Monte Carlo study of skin optical clearing to enhance light penetration in the tissue: implications for photodynamic therapy of acne vulgaris

    Science.gov (United States)

    Bashkatov, Alexey N.; Genina, Elina A.; Tuchin, Valery V.; Altshuler, Gregory B.; Yaroslavsky, Ilya V.

    2008-06-01

    Result of Monte Carlo simulations of skin optical clearing is presented. The model calculations were carried out with the aim of studying of spectral response of skin under immersion liquids action and calculation of enhancement of light penetration depth. In summary, we have shown that: 1) application of glucose, propylene glycol and glycerol produced significant decrease of light scattering in different skin layers; 2) maximal clearing effect will be obtained in case of optical clearing of skin dermis, however, absorbed light fraction in skin dermis changed insignificantly, independently on clearing agent and place it administration; 3) in contrast to it, the light absorbed fraction in skin adipose layer increased significantly in case of optical clearing of skin dermis. It is very important because it can be used for development of optical methods of obesity treatment; 4) optical clearing of superficial skin layers can be used for decreasing of power of light radiation used for treatment of acne vulgaris.

  14. Using an Electron Scanning Microscope to Assess the Penetrating Abilities of an Experimental Preparation with Features of a Dental Infiltrant: Preliminary Study.

    Science.gov (United States)

    Skucha-Nowak, Małgorzata; Mertas, Anna; Tanasiewicz, Marta

    2016-01-01

    The resin infiltration technique is one of the micro-invasive methods whose aim is the penetration of demineralized enamel with a low viscosity resin. This technique allows the dentist to avoid the application of mechanical means of treatment. The objective of this preliminary study was to attempt to determine the possibilities of using an electron microscope to assess the penetrating abilities of an experimental preparation with features of a dental infiltrant and to compare the depth of infiltration of the designed experimental preparation with an infiltrant available on the market. A bioactive methacrylate monomer based on PMMAn with built-in metronidazole was synthesized. The commercially available Icon solution (with contrast agent YbF3) and the experimental solution were applied to the relevant parts of teeth. The dissected sections along the long tooth axis and polished surfaces were then examined with use of an electron scanning microscope. The backscattered electron technique gives much better results than the secondary electron method as it makes it possible to localize even very small YbF3 particles. The authors concluded that the backscattered electron technique gives much better results than the secondary electron method as it makes it possible to localize even very small particles of the contrast agent. In order to prevent blockage of decalcified enamel tissue by ytterbium trifluoride (YbF3) grains, a nanoparticle form of that compound should be used (that is, particles with sizes in the range of 10-9 m).

  15. A study of drying and cleaning methods used in preparation for fluorescent penetrant inspection - Part II

    International Nuclear Information System (INIS)

    Brasche, L.; Lopez, R.; Larson, B.

    2003-01-01

    Fluorescent penetrant inspection is the most widely used method for aerospace components such as critical rotating components of gas turbine engines. Successful use of FPI begins with a clean and dry part, followed by a carefully controlled and applied FPI process, and conscientious inspection by well trained personnel. A variety of cleaning methods are in use for cleaning of titanium and nickel parts with selection based on the soils or contamination to be removed. Cleaning methods may include chemical or mechanical methods with sixteen different types studied as part of this program. Several options also exist for use in drying parts prior to FPI. Samples were generated and exposed to a range of conditions to study the effect of both drying and cleaning methods on the flaw response of FPI. Low cycle fatigue (LCF) cracks were generated in approximately 40 nickel and 40 titanium samples for evaluation of the various cleaning methods. Baseline measurements were made for each of the samples using a photometer to measure sample brightness and a UVA videomicroscope to capture digital images of the FPI indications. Samples were exposed to various contaminants, cleaned and inspected. Brightness measurements and digital images were also taken to compare to the baseline data. A comparison of oven drying to flash dry in preparation for FPI has been completed and will be reported in Part I. Comparison of the effectiveness of various cleaning methods for the contaminants will be presented in Part II. The cleaning and drying studies were completed in cooperation with Delta Airlines using cleaning, drying and FPI processes typical of engine overhaul processes and equipment. The work was completed as part of the Engine Titanium Consortium and included investigators from Honeywell, General Electric, Pratt and Whitney, and Rolls Royce

  16. A study of drying and cleaning methods used in preparation for fluorescent penetrant inspection - Part I

    International Nuclear Information System (INIS)

    Brasche, L.; Lopez, R.; Larson, B.

    2003-01-01

    Fluorescent penetrant inspection is the most widely used method for aerospace components such as critical rotating components of gas turbine engines. Successful use of FPI begins with a clean and dry part, followed by a carefully controlled and applied FPI process, and conscientious inspection by well trained personnel. A variety of cleaning methods are in use for cleaning of titanium and nickel parts with selection based on the soils or contamination to be removed. Cleaning methods may include chemical or mechanical methods with sixteen different types studied as part of this program. Several options also exist for use in drying parts prior to FPI. Samples were generated and exposed to a range of conditions to study the effect of both drying and cleaning methods on the flaw response of FPI. Low cycle fatigue (LCF) cracks were generated in approximately 40 nickel and 40 titanium samples for evaluation of the various cleaning methods. Baseline measurements were made for each of the samples using a photometer to measure sample brightness and a UVA videomicroscope to capture digital images of the FPI indications. Samples were exposed to various contaminants, cleaned and inspected. Brightness measurements and digital images were also taken to compare to the baseline data. A comparison of oven drying to flash dry in preparation for FPI has been completed and will be reported in Part I. Comparison of the effectiveness of various cleaning methods for the contaminants will be presented in Part II. The cleaning and drying studies were completed in cooperation with Delta Airlines using cleaning, drying and FPI processes typical of engine overhaul processes and equipment. The work was completed as part of the Engine Titanium Consortium and included investigators from Honeywell, General Electric, Pratt and Whitney, and Rolls Royce

  17. Studies on penetration of antibiotic in bacterial cells in space conditions (7-IML-1)

    Science.gov (United States)

    Tixador, R.

    1992-01-01

    The Cytos 2 experiment was performed aboard Salyut 7 in order to test the antibiotic sensitivity of bacteria cultivated in vitro in space. An increase of the Minimal Inhibitory Concentration (MIC) in the inflight cultures (i.e., an increase of the antibiotic resistance) was observed. Complementary studies of the ultrastructure showed a thickening of the cell envelope. In order to confirm the results of the Cytos 2 experiment, we performed the ANTIBIO experiment during the D1 mission to try to differentiate, by means of the 1 g centrifuge in the Biorack, between the biological effects of cosmic rays and those caused by microgravity conditions. The originality of this experiment was in the fact that it was designed to test the antibiotic sensitivity of bacteria cultivated in vitro during the orbital phase of the flight. The results show an increase in resistance to Colistin in in-flight bacteria. The MIC is practically double in the in-flight cultures. A cell count of living bacteria in the cultures containing the different Colistin concentrations showed a significant difference between the cultures developed during space flight and the ground based cultures. The comparison between the 1 g and 0 g in-flight cultures show similar behavior for the two sets. Nevertheless, a small difference between the two sets of ground based control cultures was noted. The cultures developed on the ground centrifuge (1.4 g) present a slight decrease in comparison with the cultures developed in the static rack (1 g). In order to approach the mechanisms of the increase of antibiotic resistance on bacteria cultivated in vitro in space, we have proposed the study on penetration of antibiotics in bacterial cells in space conditions. This experiment was selected for the International Microgravity Laboratory 1 (IML-1) mission.

  18. Tumor stroma-containing 3D spheroid arrays: A tool to study nanoparticle penetration

    NARCIS (Netherlands)

    Priwitaningrum, Dwi L.; Priwitaningrum, Dwi Lestari; Blondé, Jean-Baptiste Gabriel Marie; Blonde, Jean-Baptiste G.; Sridhar, Adithya; van Baarlen, Joop; Hennink, Wim E.; Storm, Gerrit; le Gac, Severine; Prakash, Jai

    2016-01-01

    Nanoparticle penetration through tumor tissue after extravasation is considered as a key issue for tumor distribution and therapeutic effects. Most tumors possess abundant stroma, a fibrotic tissue composed of cancer-associated fibroblasts (CAFs) and extracellular matrix (ECM), which acts as a

  19. A theoretical study of cold nuclear fusion using barrier penetration approach

    International Nuclear Information System (INIS)

    Gupta, S.K.; Gupta, R.K.

    1989-06-01

    The cold nuclear fusion process is investigated in terms of barrier penetration calculations by considering both the deuteron-molecule and colliding deuteron-deuteron atoms. Atomic collisions with strongly screened interatomic potential and the resonant state formation can bring agreement with present experimental results. Analysis of the data in terms of the reaction rates is also discussed. (author). 13 refs, 1 tab

  20. Development of a HPLC method for determination of four UV filters in sunscreen and its application to skin penetration studies.

    Science.gov (United States)

    Souza, Carla; Maia Campos, Patrícia M B G

    2017-12-01

    This study describes the development, validation and application of a high-performance liquid chromatography (HPLC) method for the simultaneous determination of the in vitro skin penetration profile of four UV filters on porcine skin. Experiments were carried out on a gel-cream formulation containing the following UV filters: diethylamino hydroxybenzoyl hexyl benzoate (DHHB), bis-ethylhexyloxyphenol methoxyphenyl triazine (BEMT), methylene bis-benzotriazolyl tetramethylbutylphenol (MBBT) and ethylhexyl triazone (EHT). The HPLC method demonstrated suitable selectivity, linearity (10.0-50.0 μg/mL), precision, accuracy and recovery from porcine skin and sunscreen formulation. The in vitro skin penetration profile was evaluated using Franz vertical diffusion cells for 24 h after application on porcine ear skin. None of the UV filters penetrated the porcine skin. Most of them stayed on the skin surface (>90%) and only BEMT, EHT and DHHB reached the dermis plus epidermis layer. These results are in agreement with previous results in the literature. Therefore, the analytical method was useful to evaluate the in vitro skin penetration of the UV filters and may help the development of safer and effective sunscreen products. Copyright © 2017 John Wiley & Sons, Ltd.

  1. A study of changes in the primary dose penetrating the protective apron on SID in x-ray radiography

    International Nuclear Information System (INIS)

    Choi, Seong Kwan

    2016-01-01

    This study is to figure out the amount of primary X-ray generated in SID 50cm, 1m, and 2m penetrating protective aprons in X-ray radiography for hands, skull, and lumbar spine. Results are as follows: Firstly, the exposure dose of primary X-ray which is low such as that of hand X-ray may be reduced by 270 times if protective aprons are worn, but it still slightly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Secondly, the exposure dose of primary X-ray which is moderate such as that of skull X-ray may be reduced by 22 times if protective aprons are worn, but it still fairly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Thirdly, the exposure dose of primary X-ray which is very high such as that of lumbar spine X-ray may be reduced b y 13 times if protective aprons a re worn, but it still penetrates a lot 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Therefore, people in X-ray room should not only wear protective aprons at any spaces that the primary X-ray can reach, but also need to stand behind the thick Pb shield to protect the body if it is inevitable to stay in the room

  2. Diagnostic accuracy of triple-contrast multi-detector computed tomography for detection of penetrating gastrointestinal injury: a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Saksobhavivat, Nitima [Faculty of Medicine Ramathibodi Hospital, Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ratchathewi, Bangkok (Thailand); Shanmuganathan, Kathirkamanathan; Boscak, Alexis R.; Sliker, Clint W.; Bodanapally, Uttam K.; Archer-Arroyo, Krystal; Miller, Lisa A.; Fleiter, Thorsten R.; Alexander, Melvin T.; Mirvis, Stuart E. [University of Maryland School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Baltimore, MD (United States); Stein, Deborah M.; Scalea, Thomas M. [University of Maryland School of Medicine, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States)

    2016-11-15

    Neither the performance of CT in diagnosing penetrating gastrointestinal injury nor its ability to discriminate patients requiring either observation or surgery has been determined. This was a prospective, single-institutional observational study of patients with penetrating injury to the torso who underwent CT. Based on CT signs, reviewers determined the presence of a gastrointestinal injury and the need for surgery or observation. The primary outcome measures were operative findings and clinical follow-up. CT results were compared with the primary outcome measures. Of one hundred and seventy-one patients (72 gunshot wounds, 99 stab wounds; age range, 18-57 years; median age, 28 years) with penetrating torso trauma who underwent CT, 45 % were followed by an operation and 55 % by clinical follow up. Thirty-five patients had a gastrointestinal injury at surgery. The sensitivity, specificity, and accuracy of CT for diagnosing a gastrointestinal injury for all patients were each 91 %, and for predicting the need for surgery, they were 94 %, 93 %, 93 %, respectively. Among the 3 % of patients who failed observation, 1 % had a gastrointestinal injury. CT is a useful technique to diagnose gastrointestinal injury following penetrating torso injury. CT can help discriminate patients requiring observation or surgery. (orig.)

  3. A study of changes in the primary dose penetrating the protective apron on SID in x-ray radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seong Kwan [Dept. of Radiological Technology, Kwangju Health University, Gwangju (Korea, Republic of)

    2016-12-15

    This study is to figure out the amount of primary X-ray generated in SID 50cm, 1m, and 2m penetrating protective aprons in X-ray radiography for hands, skull, and lumbar spine. Results are as follows: Firstly, the exposure dose of primary X-ray which is low such as that of hand X-ray may be reduced by 270 times if protective aprons are worn, but it still slightly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Secondly, the exposure dose of primary X-ray which is moderate such as that of skull X-ray may be reduced by 22 times if protective aprons are worn, but it still fairly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Thirdly, the exposure dose of primary X-ray which is very high such as that of lumbar spine X-ray may be reduced b y 13 times if protective aprons a re worn, but it still penetrates a lot 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Therefore, people in X-ray room should not only wear protective aprons at any spaces that the primary X-ray can reach, but also need to stand behind the thick Pb shield to protect the body if it is inevitable to stay in the room.

  4. Penetration of a magnetic field into superconducting lead and lead-indium alloys

    International Nuclear Information System (INIS)

    Egloff, C.; Raychaudhuri, A.K.; Rinderer, L.

    1983-01-01

    The temperature dependence of the magnetic field penetration depth of superconducting lead and lead-indium alloys has been studied over the temperature range between about 2 K and T/sub c/. Data are analyzed in terms of the microscopic theory. The difficulties of a unique analysis of the penetration data are pointed out and a strategy for the analysis is discussed. The penetration depth at T = 0K for pure lead is determined as 522 A. This value, though higher than the previously accepted value for lead, is nevertheless consistent with the strong coupling character of lead

  5. STUDY ON THE RETRIEVAL OF SNOW DEPTH FROM FY3B/MWRI IN THE ATCTIC

    Directory of Open Access Journals (Sweden)

    L. Li

    2016-06-01

    Full Text Available temperatures. Given the high albedo and low thermal conductivity, snow is regarded as one of the key reasons for the amplification of the warming in polar regions. The distributions of sea ice and snow depth are essential to the whole thermal conduction in the Arctic. This study focused on the retrieval of snow depth on sea ice from brightness temperatures of the MicroWave Radiometer Imager (MWRI onboard the FengYun (FY-3B satellite during the period from December 1, 2010 to April 30, 2011. After cross calibrated to the Advanced Microwave Scanning Radiometer–EOS (AMSR-E Level 2A data, the MWRI brightness temperatures were applied to calculate the sea ice concentrations based on the Arctic Radiation and Turbulence Interaction Study Sea Ice (ASI algorithm. According to the proportional relationship between the snow depth and the surface scattering in 18.7 and 36.5 GHz, the snow depths were derived. In order to eliminate the influence of uncertainties in grain sizes of snow as well as sporadic weather effects, the seven-day averaged snow depths were calculated. Then the results were compared with the snow depths from the AMSR-E Level 3 Sea Ice products. The bias of differences between the MWRI and the AMSR-E Level 3 products are ranged between −1.09 and −0.32 cm,while the standard deviations and the correlation coefficients are ranged from 2.47 to 2.88 cm and from 0.78 to 0.90 for different months. As a result, it could be summarized that FY3B/MWRI showed a promising prospect in retrieving snow depth on sea ice.

  6. Evaluation of Skin Penetration of Diclofenac from a Novel Topical Non Aqueous Solution: A Comparative Bioavailability Study.

    Science.gov (United States)

    Nivsarkar, Manish; Maroo, Sanjaykumar H; Patel, Ketan R; Patel, Dixit D

    2015-12-01

    Different topical formulations of diclofenac have varying skin penetration profile. Recent advances in science and technology has led to the development of many new formulations of drugs for topical drug delivery. One such technological development has led to the innovation of Dynapar QPS, a novel, non-aqueous, quick penetrating solution (QPS) of diclofenac diethylamine. This study was aimed to measure the total exposure from the drug penetrating the skin in healthy human subjects and comparing the relative systemic bioavailability of Dynapar QPS(®) with diclofenac emulgel. A 200 mg of diclofenac from either Dynapar QPS(®) (5 ml) or emulgel (20 g) was applied on back of subject as per the randomisation schedule. Blood samples were collected up to 16 hours post drug application. Plasma concentration of diclofenac was measured by pre-validated HPLC method. Pharmacokinetic (PK) parameters like Cmax, Tmax, t1/2, AUC0-t, AUC0-∞, and Kel, of diclofenac were determined for both the formulations. Mean Cmax after administration of Dynapar QPS(®) and diclofenac emulgel were 175.93 and 40.04 ng/ml, respectively. Tmax of diclofenac was almost half with QPS compared to emulgel (5.24 hrs versus 9.53 hrs respectively). The mean AUC0-t and AUC0-∞ after administration of Dynapar QPS(®) was higher as compared to diclofenac emulgel (AUC0-t: 1224.19 versus 289.78 ng.h/ml, respectively; AUC0-∞: 1718.21 versus 513.83 ng.h/ml, respectively). None of the subject experienced any adverse event during the study. The results indicate an enhanced penetration and subsequent absorption of diclofenac from Dynapar QPS(®) as compared to diclofenac emulgel. Higher penetration is likely to translate into better pain relief in patients.

  7. Effect of skin tumor properties on laser penetration

    CSIR Research Space (South Africa)

    Karsten, AE

    2009-06-01

    Full Text Available Computer modeling can be a valuable tool to determine the absorption of laser light in different skin layers. For this study, the optical properties of three different skin tumors were used in the model to evaluate the effect on penetration depth...

  8. Quantitative study of the penetration of insoluble particles into the tissue of the conducting airways

    Energy Technology Data Exchange (ETDEWEB)

    Gore, D J; Patrick, G [Medical Research Council, Harwell (UK). Radiobiological Research Unit

    1982-01-01

    A quantitative study is presented of the spatial distribution of both inhaled UO/sub 2/ particles and intra-tracheally administered BaSO/sub 4/ particles in the wall of the airways in the rat. The results show that in the intrapulmonary airways between 7 and 17 days after inhalation, UO/sub 2/ particles are situated most frequently at a depth of 8-10 ..mu..m from the luminal surface. At 24 h in the trachea, BaSO/sub 4/ particles concentrate between 10 and 15 ..mu..m beneath the surface, corresponding to the zone immediately beneath the basement membrane; by 7 days the distribution is broader but otherwise similar. This pattern of retention should assist in assessing the dose from radioactive particles absorbed by the basal cells of the epithelium, which are likely to be the origin of carcinoma of the airways.

  9. A Case Study on the Perceptions of Educators on the Penetration of Personal Learning Environments in Typical Education

    OpenAIRE

    Armakolas, Stefanos; Mikroyannidis, Alexander; Panagiotakopoulos, Christos; Panousopoulou, Theofania

    2016-01-01

    Personal Learning Environments (PLEs) help students manage and take control of their own learning. As such, the PLE promotes self-regulation in learning and allows learners to aggregate, manipulate and share digital artefacts within a flexible and versatile online space. This paper presents a case study in Greece, concerning an investigation about the penetration of PLEs in typical education. In particular, this case study aims at investigating the perceptions of educators about PLEs and thei...

  10. Preliminary study of corneal penetration of /sup 125/I-labelled idoxuridine liposome

    Energy Technology Data Exchange (ETDEWEB)

    Dharma, S.K.; Fishman, P.H.; Peyman, G.A.

    1986-01-01

    We compared corneal penetration of idoxuridine (IDU) to liposome-encapsulated IDU. Liposomes of phosphatidic acid, phosphatidyl choline and alphatocopherol in a molar ratio 1:8:1 were prepared using the reverse phase evaporation method. New Zealand albino rabbits received either 0.1% solution of I/sup 125/-labelled aqueous IDU or liposome-encapsulated IDU topically every 2 min for 6 min. Corneal, aqueous, and vitreous samples were assayed for I/sup 125/ radioactivity at 15 min and at 1, 2, 3, and 6 h following drug application. Our results indicated that corneal penetration of liposomal IDU was significantly increased over the regular form of the drug for a time interval of 6 h.

  11. A preliminary study of corneal penetration of 125I-labelled idoxuridine liposome

    International Nuclear Information System (INIS)

    Dharma, S.K.; Fishman, P.H.; Peyman, G.A.

    1986-01-01

    We compared corneal penetration of idoxuridine (IDU) to liposome-encapsulated IDU. Liposomes of phosphatidic acid, phosphatidyl choline and alphatocopherol in a molar ratio 1:8:1 were prepared using the reverse phase evaporation method. New Zealand albino rabbits received either 0.1% solution of I 125 -labelled aqueous IDU or liposome-encapsulated IDU topically every 2 min for 6 min. Corneal, aqueous, and vitreous samples were assayed for I 125 radioactivity at 15 min and at 1, 2, 3, and 6 h following drug application. Our results indicated that corneal penetration of liposomal IDU was significantly increased over the regular form of the drug for a time interval of 6 h. (author)

  12. Projectile penetration into ballistic gelatin.

    Science.gov (United States)

    Swain, M V; Kieser, D C; Shah, S; Kieser, J A

    2014-01-01

    Ballistic gelatin is frequently used as a model for soft biological tissues that experience projectile impact. In this paper we investigate the response of a number of gelatin materials to the penetration of spherical steel projectiles (7 to 11mm diameter) with a range of lower impacting velocities (projectile velocity are found to be linear for all systems above a certain threshold velocity required for initiating penetration. The data for a specific material impacted with different diameter spheres were able to be condensed to a single curve when the penetration depth was normalised by the projectile diameter. When the results are compared with a number of predictive relationships available in the literature, it is found that over the range of projectiles and compositions used, the results fit a simple relationship that takes into account the projectile diameter, the threshold velocity for penetration into the gelatin and a value of the shear modulus of the gelatin estimated from the threshold velocity for penetration. The normalised depth is found to fit the elastic Froude number when this is modified to allow for a threshold impact velocity. The normalised penetration data are found to best fit this modified elastic Froude number with a slope of 1/2 instead of 1/3 as suggested by Akers and Belmonte (2006). Possible explanations for this difference are discussed. © 2013 Published by Elsevier Ltd.

  13. Effects of magnification and zooming on depth perception in digital stereomammography: an observer performance study

    International Nuclear Information System (INIS)

    Chan Heangping; Goodsitt, Mitchell M; Hadjiiski, Lubomir M; Bailey, Janet E; Klein, Katherine; Darner, Katie L; Sahiner, Berkman

    2003-01-01

    We are evaluating the application of stereoscopic imaging to digital mammography. In the current study, we investigated the effects of magnification and zooming on depth perception. A modular phantom was designed which contained six layers of 1-mm-thick Lexan plates, each spaced 1 mm apart. Eight to nine small, thin nylon fibrils were pasted on each plate in horizontal or vertical orientations such that they formed 25 crossing fibril pairs in a projected image. The depth separation between each fibril pair ranged from 2 to 10 mm. A change in the order of the Lexan plates changed the depth separation of the two fibrils in a pair. Stereoscopic image pairs of the phantom were acquired with a GE full-field digital mammography system. Three different phantom configurations were imaged. All images were obtained using a Rh target/Rh filter spectrum at 30 kVp tube potential and a ±3 degrees stereo shift angle. Images were acquired in both contact and 1.8X magnification geometry and an exposure range of 4 to 63 mAs was employed. The images were displayed on a Barco monitor driven by a Metheus stereo graphics board and viewed with LCD stereo glasses. Five observers participated in the study. Each observer visually judged whether the vertical fibril was in front of or behind the horizontal fibril in each fibril pair. It was found that the accuracy of depth discrimination increased with increasing fibril depth separation and x-ray exposure. The accuracy was not improved by electronic display zooming of the contact stereo images by 2X. Under conditions of high noise (low mAs) and small depth separation between the fibrils, the observers' depth discrimination ability was significantly better in stereo images acquired with geometric magnification than in images acquired with a contact technique and displayed with or without zooming. Under our experimental conditions, a 2 mm depth discrimination was achieved with over 60% accuracy on contact images with and without zooming, and

  14. On depth profiling of hydrogen and helium isotopes and its application to ion-implantation studies

    International Nuclear Information System (INIS)

    Boettiger, J.

    1979-01-01

    The thesis is divided into two parts, the first being a general review of the experimental methods for depth profiling of light isotopes, where ion beams are used. In the second part, studies of ion implantation of hydrogen and helium isotopes, applying the techniques discussed in the first part, are described. The paper summarizes recent experimental results and discusses recent developments. (Auth.)

  15. The results interpretation of thermogasdynamic studies of vertical gas wells incomplete in terms of the reservoir penetration degree

    Directory of Open Access Journals (Sweden)

    M.N. Shamsiev

    2018-03-01

    Full Text Available A method is proposed for interpreting thermogasdynamic studies of vertical gas wells that are incomplete in terms of the reservoir penetration degree on the basis of inverse tasks theory. The inverse task has the aim to determine the reservoir parameters for nonisothermal filtration of a real gas to a vertical well in an anisotropic reservoir. In this case, the values ​​of the pressure and temperature at the well bottom, recorded by deep instruments, are assumed to be known. The solution of the inverse task is to minimize the functional. The iterative sequence for minimizing the functional is based on the Levenberg-Marquardt method. The convergence and stability of the iterative process for various input information have been studied on specific examples. The effect of reservoir anisotropy on the pressure and temperature changes at the bottom of the well is studied. It is shown that if the reservoir is not completely penetrated by the results of pressure and temperature measurements at the bottom of the well, anisotropy of the reservoir can be estimated after its launch. It should be noted that when studying thermodynamic processes in the vicinity of a well, which penetrates thick layers, it is necessary to take into account not only the heat exchange of the reservoir with the surrounding rocks, but also the geothermal temperature gradient.

  16. Building application of solar energy. Study no. 2: Representative buildings for solar energy performance analysis and market penetration

    Science.gov (United States)

    Hirshberg, A. S.

    1975-01-01

    The following topics are discussed: (1) Assignment of population to microclimatic zones; (2) specifications of the mix of buildings in the SCE territory; (3) specification of four typical buildings for thermal analysis and market penetration studies; (4) identification of the materials and energy conserving characteristics of these typical buildings; (5) specifications of the HVAC functions used in each typical building, and determination of the HVAC systems used in each building; and (6) identification of the type of fuel used in each building.

  17. Long-rod penetration: the transition zone between rigid and hydrodynamic penetration modes

    Directory of Open Access Journals (Sweden)

    Jian-feng Lou

    2014-06-01

    Full Text Available Long-rod penetration in a wide range of velocity means that the initial impact velocity varies in a range from tens of meters per second to several kilometers per second. The long rods maintain rigid state when the impact velocity is low, the nose of rod deforms and even is blunted when the velocity gets higher, and the nose erodes and fails to lead to the consumption of long projectile when the velocity is very high due to instantaneous high pressure. That is, from low velocity to high velocity, the projectile undergoes rigid rods, deforming non-erosive rods, and erosive rods. Because of the complicated changes of the projectile, no well-established theoretical model and numerical simulation have been used to study the transition zone. Based on the analysis of penetration behavior in the transition zone, a phenomenological model to describe target resistance and a formula to calculate penetration depth in transition zone are proposed, and a method to obtain the boundary velocity of transition zone is determined. A combined theoretical analysis model for three response regions is built by analyzing the characteristics in these regions. The penetration depth predicted by this combined model is in good agreement with experimental result.

  18. Depth Profiles in Maize ( Zea mays L.) Seeds Studied by Photoacoustic Spectroscopy

    Science.gov (United States)

    Hernández-Aguilar, C.; Domínguez-Pacheco, A.; Cruz-Orea, A.; Zepeda-Bautista, R.

    2015-06-01

    Photoacoustic spectroscopy (PAS) has been used to analyze agricultural seeds and can be applied to the study of seed depth profiles of these complex samples composed of different structures. The sample depth profile can be obtained through the photoacoustic (PA) signal, amplitude, and phase at different light modulation frequencies. The PA signal phase is more sensitive to changes of thermal properties in layered samples than the PA signal amplitude. Hence, the PA signal phase can also be used to characterize layers at different depths. Thus, the objective of the present study was to obtain the optical absorption spectra of maize seeds ( Zea mays L.) by means of PAS at different light modulation frequencies (17 Hz, 30 Hz, and 50 Hz) and comparing these spectra with the ones obtained from the phase-resolved method in order to separate the optical absorption spectra of seed pericarp and endosperm. The results suggest the possibility of using the phase-resolved method to obtain optical absorption spectra of different seed structures, at different depths, without damaging the seed. Thus, PAS could be a nondestructive method for characterization of agricultural seeds and thus improve quality control in the food industry.

  19. Spar-Type Vertical-Axis Wind Turbines in Moderate Water Depth: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Ting Rui Wen

    2018-03-01

    Full Text Available The applications of floating vertical-axis wind turbines (VAWTs in deep water have been proposed and studied by several researchers recently. However, the feasibility of deploying a floating VAWT at a moderate water depth has not yet been studied. In this paper, this feasibility is thoroughly addressed by comparing the dynamic responses of spar-type VAWTs in deep water and moderate water depth. A short spar VAWT supporting a 5 MW Darrieus rotor at moderate water depth is proposed by following the deep spar concept in deep water. A fully coupled simulation tool, SIMO-RIFLEX-DMS code, is utilized to carry out time domain simulations under turbulent wind and irregular waves. Dynamic responses of the short spar and deep spar VAWTs are analyzed and compared, including the natural periods, wind turbine performance, platform motions, tower base bending moments, and tension of mooring lines. The statistical characteristics of the thrust and power production for both spars are similar. The comparison of platform motions and tower base bending moments demonstrate a good agreement for both spars, but the short spar has better performance in surge/sway motions and side–side bending moments. The 2P response dominates the bending moment spectra for both spars. A significant variation in tension of Mooring Line 1 and a larger corresponding spectrum value are found in the short spar concept. The results indicate that the application of short spar VAWTs is feasible and could become an alternative concept at moderate water depth.

  20. Lipid nanoparticles for topical and transdermal application for alopecia treatment: development, physicochemical characterization, and in vitro release and penetration studies

    DEFF Research Database (Denmark)

    Gomes, M. J.; Martins, S.; Ferreira, D.

    2014-01-01

    with few side effects, new drug-delivery systems able to improve alopecia therapy are urgently required. With this purpose in mind, the present study aimed to develop lipid nanoparticles (nanostructured lipid carriers) with the ability to incorporate and deliver anti-alopecia active compounds (minoxidil...... less than 30% was achieved for minoxidil nanoparticles, over 28 days. Controlled release assays in physiological conditions demonstrated that nanoparticles loaded with minoxidil yielded a prolonged release, as desired. Penetration assays through pig ear skin demonstrated that nanoparticles loaded...... with minoxidil and finasteride had low levels of penetration. These results suggest that the proposed novel formulation presents several good characteristics indicating their suitability for dermal delivery of anti-alopecia active compounds....

  1. Microwave study of magnetic field penetration parallel to thin niobium films

    International Nuclear Information System (INIS)

    Grbic, M.S.; Janjusevic, D.; Pozek, M.; Dulcic, A.; Wagner, T.

    2007-01-01

    Complex conductivity of high quality niobium thin films has been investigated by microwave technique in parallel static magnetic field. For the 40 nm thick film no vortices can be formed and the microwave penetration is defined by the strength of the superconducting order parameter which varies with the applied magnetic field. 160 nm thick measured film allows formation of two rows of vortices. Microwave dissipiation is dominated by dynamics of vortices which is strongly affected by size effects. Results have been compared with the generalised models of complex conductivity for low-dimensional superconductor in mixed state following earlier considerations by other authors

  2. Theoretical study of the attenuation of a gaussian beam penetrating into a dielectric circular wave guide

    International Nuclear Information System (INIS)

    Crenn, J.P.

    1981-07-01

    It is proposed to draw up an approximate formula directly giving the attenuation of a gaussian beam penetrating into a superdimensioned dielectric circular wave guide. This formula is derived from optical laws, i.e. Fresnel's formulae of the reflexion of a wave on a dielectric to which a correcting term due to diffraction has been added. The results given by this formula are compared with the existing results, based on the breakdown of a gaussian beam into propagation modes, thereby enabling their validity and the field of use to be checked. An application is then made to the wave guides that will be employed in the infrared interferometer fitted in JET [fr

  3. Experimental study on the evolution of Peregrine breather with uniform-depth adverse currents

    Science.gov (United States)

    Liao, B.; Ma, Y.; Ma, X.; Dong, G.

    2018-05-01

    A series of laboratory experiments were performed to study the evolution of Peregrine breather (PB) in a wave flume in finite depth, and wave trains were initially generated in a region of quiescent water and then propagated into an adverse current region for which the current velocity strength gradually increased from zero to an approximately stable value. The PB is often considered as a prototype of oceanic freak waves that can focus wave energy into a single wave packet. In the experiment, the cases were selected with the relative water depths k0h (k0 is the wave number in quiescent water and h is the water depth) varying from 3.11 through 8.17, and the initial wave steepness k0a0 (a0 is the background wave amplitude) ranges between 0.065 and 0.120. The experimental results show the persistence of the breather evolution dynamics even in the presence of strong opposing currents. We have shown that the characteristic spectrum of the PB persists even on strong currents, thus making it a viable characteristic for prediction of freak waves. It was also found that the adverse currents tend to shift the focusing point upstream compared to the cases without currents. Furthermore, it was found that uniform-depth adverse currents can reduce the breather extension in time domain.

  4. Human cortical neural correlates of visual fatigue during binocular depth perception: An fNIRS study.

    Directory of Open Access Journals (Sweden)

    Tingting Cai

    Full Text Available Functional near-infrared spectroscopy (fNIRS was adopted to investigate the cortical neural correlates of visual fatigue during binocular depth perception for different disparities (from 0.1° to 1.5°. By using a slow event-related paradigm, the oxyhaemoglobin (HbO responses to fused binocular stimuli presented by the random-dot stereogram (RDS were recorded over the whole visual dorsal area. To extract from an HbO curve the characteristics that are correlated with subjective experiences of stereopsis and visual fatigue, we proposed a novel method to fit the time-course HbO curve with various response functions which could reflect various processes of binocular depth perception. Our results indicate that the parietal-occipital cortices are spatially correlated with binocular depth perception and that the process of depth perception includes two steps, associated with generating and sustaining stereovision. Visual fatigue is caused mainly by generating stereovision, while the amplitude of the haemodynamic response corresponding to sustaining stereovision is correlated with stereopsis. Combining statistical parameter analysis and the fitted time-course analysis, fNIRS could be a promising method to study visual fatigue and possibly other multi-process neural bases.

  5. Penetration in bimodal, polydisperse granular material

    KAUST Repository

    Kouraytem, Nadia; Thoroddsen, Sigurdur T; Marston, J. O.

    2016-01-01

    We investigate the impact penetration of spheres into granular media which are compositions of two discrete size ranges, thus creating a polydisperse bimodal material. We examine the penetration depth as a function of the composition (volume fractions of the respective sizes) and impact speed. Penetration depths were found to vary between delta = 0.5D(0) and delta = 7D(0), which, for mono-modal media only, could be correlated in terms of the total drop height, H = h + delta, as in previous studies, by incorporating correction factors for the packing fraction. Bimodal data can only be collapsed by deriving a critical packing fraction for each mass fraction. The data for the mixed grains exhibit a surprising lubricating effect, which was most significant when the finest grains [d(s) similar to O(30) mu m] were added to the larger particles [d(l) similar to O(200 - 500) mu m], with a size ratio, epsilon = d(l)/d(s), larger than 3 and mass fractions over 25%, despite the increased packing fraction. We postulate that the small grains get between the large grains and reduce their intergrain friction, only when their mass fraction is sufficiently large to prevent them from simply rattling in the voids between the large particles. This is supported by our experimental observations of the largest lubrication effect produced by adding small glass beads to a bed of large sand particles with rough surfaces.

  6. Penetration in bimodal, polydisperse granular material

    KAUST Repository

    Kouraytem, N.

    2016-11-07

    We investigate the impact penetration of spheres into granular media which are compositions of two discrete size ranges, thus creating a polydisperse bimodal material. We examine the penetration depth as a function of the composition (volume fractions of the respective sizes) and impact speed. Penetration depths were found to vary between delta = 0.5D(0) and delta = 7D(0), which, for mono-modal media only, could be correlated in terms of the total drop height, H = h + delta, as in previous studies, by incorporating correction factors for the packing fraction. Bimodal data can only be collapsed by deriving a critical packing fraction for each mass fraction. The data for the mixed grains exhibit a surprising lubricating effect, which was most significant when the finest grains [d(s) similar to O(30) mu m] were added to the larger particles [d(l) similar to O(200 - 500) mu m], with a size ratio, epsilon = d(l)/d(s), larger than 3 and mass fractions over 25%, despite the increased packing fraction. We postulate that the small grains get between the large grains and reduce their intergrain friction, only when their mass fraction is sufficiently large to prevent them from simply rattling in the voids between the large particles. This is supported by our experimental observations of the largest lubrication effect produced by adding small glass beads to a bed of large sand particles with rough surfaces.

  7. The functions of atrial strands interdigitating with and penetrating into sinoatrial node: a theoretical study of the problem.

    Directory of Open Access Journals (Sweden)

    Xiaodong Huang

    Full Text Available The sinoatrial node (SAN-atrium system is closely involved with the activity of heart beating. The impulse propagation and phase-locking behaviors of this system are of theoretical interest. Some experiments have revealed that atrial strands (ASs interdigitate with and penetrate into the SAN, whereby the SAN-atrium system works as a complex network. In this study, the functions of ASs are numerically investigated using realistic cardiac models. The results indicate that the ASs penetrating into the central region of the SAN play a major role in propagating excitation into the atrium. This is because the threshold SAN-AS coupling for an AS to function as an alternative path for propagation is lower at the center than at the periphery. However, ASs penetrating into the peripheral region have a great effect in terms of enlarging the 1:1 entrainment range of the SAN because the automaticity of the SAN is evidently reduced by ASs. Moreover, an analytical formula for approximating the enlargement of the 1:1 range is derived.

  8. Study of the Penetration Bias of ENVISAT Altimeter Observations over Antarctica in Comparison to ICESat Observations

    Directory of Open Access Journals (Sweden)

    Aurélie Michel

    2014-09-01

    Full Text Available The aim of this article is to characterize the penetration bias of the ENVIronmental SATellite (ENVISAT radar altimeter over the Antarctic ice sheet through comparison with the more accurate measurements of the Ice, Cloud and land Elevation Satellite (ICESat altimeter at crossover points. We studied the difference between ENVISAT and ICESat fluctuations over six years. We observed the same patterns between the leading edge width and the elevation difference. Both parameters are linked, and the major bias is due to the lengthening of the leading edge width due to the radar penetration. We show that the elevation difference between both altimeters and the leading edge width are linearly well-linked with a 0.8 Pearson correlation coefficient, whereas the slope effect over the coasts is difficult to analyze. When we analyze each crossover point temporal evolution locally, the linear correlation between the leading edge width and the elevation difference is between −0.6 and −1. Fitting a linear model between them, we find a reliability index greater than 0.7 for the Antarctic Plateau and Dronning Maud Land, which confirms that the penetration effect has a linear influence on the retrieved height. Moreover, we present results from SARAL/AltiKa (launched in February 2013 that confirm SARAL/AltiKa accuracy and the promising information it will provide.

  9. Field penetration induced charge redistribution effects on the field emission properties of carbon nanotubes - a first-principle study

    International Nuclear Information System (INIS)

    Chen, C.-W.; Lee, M.-H.; Clark, S.J.

    2004-01-01

    The effect of field penetration induced charge redistribution on the field emission properties of carbon nanotubes (CNTs) have been studied by the first-principle calculations. It is found that the carbon nanotube becomes polarized under external electric field leading to a charge redistribution. The resulting band bending induced by field penetration into the nanotube tip surface can further reduce the effective workfunction of the carbon nanotubes. The magnitude of the redistributed charge ΔQ is found to be nearly linear to the applied external field strength. In addition, we found that the capped (9, 0) zigzag nanotube demonstrates better field emission properties than the capped (5, 5) armchair nanotube due to the fact that the charge redistribution of π electrons along the zigzag-like tube axis is easier than for the armchair-like tube. The density of states (DOS) of the capped region of the nanotube is found to be enhanced with a value 30% higher than that of the sidewall part for the capped (5, 5) nanotube and 40% for the capped (9, 0) nanotube under an electric field of 0.33 V/A. Such enhancements of the DOS at the carbon nanotube tip show that electrons near the Fermi level will emit more easily due to the change of the surface band structure resulting from the field penetration in a high field

  10. In-depth morphological study of mesiobuccal root canal systems in maxillary first molars: review

    Directory of Open Access Journals (Sweden)

    Seok-Woo Chang

    2013-02-01

    Full Text Available A common failure in endodontic treatment of the permanent maxillary first molars is likely to be caused by an inability to locate, clean, and obturate the second mesiobuccal (MB canals. Because of the importance of knowledge on these additional canals, there have been numerous studies which investigated the maxillary first molar MB root canal morphology using in vivo and laboratory methods. In this article, the protocols, advantages and disadvantages of various methodologies for in-depth study of maxillary first molar MB root canal morphology were discussed. Furthermore, newly identified configuration types for the establishment of new classification system were suggested based on two image reformatting techniques of micro-computed tomography, which can be useful as a further 'Gold Standard' method for in-depth morphological study of complex root canal systems.

  11. A study of penetration test for applying a remote monitoring system for virtual private network

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Park, I. J.; Min, K. S.; Choi, Y. M. [KAERI, Taejon (Korea, Republic of); Jo, D. K. [A3 Security Consulting Co., Seoul (Korea, Republic of)

    2003-07-01

    A penetration test has been performed to verify the vulnerability of Virtual Private Network that is substitute for communication method of an existing remote monitoring system. An existing RMS was used for the private telephone and the RMS was applied of all PWR in Korea. But, due to communication fee, IAEA wanted to replace current telephone line to the internet line to reduce transmission cost in operating remote monitoring system. The communication cost of telephone line was estimated about $66,000/yr. Internet technology would reduce the operating cost up to 1/5. The purpose of the penetration test was to demonstrate the security of the data and system against both various external and internal hacking scenarios. In most cases, hacker could not even identify the VPN system. In any cases, the system did not allow the access of the hacker to the system needless to say the data alteration or system shutdown. Two kinds of test method is chosen; one is external attack and another is internal attack. During the test, the hacking tool was used. The result of test was proved that VPN was secure against internal/external attack.

  12. A study of penetration test for applying a remote monitoring system for virtual private network

    International Nuclear Information System (INIS)

    Kim, J. S.; Kim, J. S.; Park, I. J.; Min, K. S.; Choi, Y. M.; Jo, D. K.

    2003-01-01

    A penetration test has been performed to verify the vulnerability of Virtual Private Network that is substitute for communication method of an existing remote monitoring system. An existing RMS was used for the private telephone and the RMS was applied of all PWR in Korea. But, due to communication fee, IAEA wanted to replace current telephone line to the internet line to reduce transmission cost in operating remote monitoring system. The communication cost of telephone line was estimated about $66,000/yr. Internet technology would reduce the operating cost up to 1/5. The purpose of the penetration test was to demonstrate the security of the data and system against both various external and internal hacking scenarios. In most cases, hacker could not even identify the VPN system. In any cases, the system did not allow the access of the hacker to the system needless to say the data alteration or system shutdown. Two kinds of test method is chosen; one is external attack and another is internal attack. During the test, the hacking tool was used. The result of test was proved that VPN was secure against internal/external attack

  13. Photoacoustic study of the penetration kinetics of nimesulid into human skin

    International Nuclear Information System (INIS)

    Barja, P R; Veloso, D J D V

    2010-01-01

    The photoacoustic (PA) effect is observed when modulated (or pulsed) light is absorbed by a sample inside a closed chamber and converted in heat, generating acoustic waves; PA measurements have been employed to evaluate transdermal penetration of topically applied drugs. Phonophoresis is the utilization of ultrasonic (US) energy to enhance absorption of drugs across the epidermal barrier, and its usefulness has been shown by PA measurements. The aim of the present work was to determine the characteristic absorption times of the anti-inflammatory Nimesulid (gel) in human skin, with and without help of therapeutic phonophoresis. After local cleaning, measurements were performed in the forearm of each volunteer before Nimesulid application and for different times after application through massage with the US equipment head; the protocol was repeated for the opposite forearm, but without US emission. Curves of the PA signal level as a function of time were adjusted by a Boltzmann equation, leading to the determination of the characteristic absorption time (about 12 minutes). No significant gain was observed in Nimesulid absorption with the utilization of US radiation, indicating that topic application of Nimesulid does not require the use of phonophoresis, due to the natural fast penetration of the Nimesulid gel.

  14. Integrated computation model of lithium-ion battery subject to nail penetration

    International Nuclear Information System (INIS)

    Liu, Binghe; Yin, Sha; Xu, Jun

    2016-01-01

    Highlights: • A coupling model to predict battery penetration process is established. • Penetration test is designed and validates the computational model. • Governing factors of the penetration induced short-circuit is discussed. • Critical safety battery design guidance is suggested. - Abstract: The nail penetration of lithium-ion batteries (LIBs) has become a standard battery safety evaluation method to mimic the potential penetration of a foreign object into LIB, which can lead to internal short circuit with catastrophic consequences, such as thermal runaway, fire, and explosion. To provide a safe, time-efficient, and cost-effective method for studying the nail penetration problem, an integrated computational method that considers the mechanical, electrochemical, and thermal behaviors of the jellyroll was developed using a coupled 3D mechanical model, a 1D battery model, and a short circuit model. The integrated model, along with the sub-models, was validated to agree reasonably well with experimental test data. In addition, a comprehensive quantitative analysis of governing factors, e.g., shapes, sizes, and displacements of nails, states of charge, and penetration speeds, was conducted. The proposed computational framework for LIB nail penetration was first introduced. This framework can provide an accurate prediction of the time history profile of battery voltage, temperature, and mechanical behavior. The factors that affected the behavior of the jellyroll under nail penetration were discussed systematically. Results provide a solid foundation for future in-depth studies on LIB nail penetration mechanisms and safety design.

  15. Draft At-Depth Study Plan for an exploratory shaft facility in salt: Revision 1

    International Nuclear Information System (INIS)

    1988-03-01

    This draft At-Depth Study Plan describes a program of at-depth monitoring and testing in the bedded salt deposits of a candidate high-level nuclear waste repository site in Deaf Smith County, Texas. The test program will be undertaken within an At-Depth Facility (ADF) constructed at the candidate repository horizon. The purpose of the program is to assist with site characterization in support of determination of site suitability for development as a repository and for preparation of licensing documentation, and to provide information in support of repository design and performance assessment evaluation. The program includes a variety of geological, geophysical, geomechanical, thermochemical, and geohydrological monitoring and testing. The program is presented as a series of separate studies concerned with geological, geomechanical, and geohydrological site characterization, and with evaluating the mechanical and hydrological response of the site to construction of the ADF. The various studies, and associated test or monitoring methods, are included. Specific large-scale tests concerned with evaluating the performance of engineered components of the repository system (i.e., rooms, waste package, bulkhead and backfill seals) will be performed in the ADF but are described separately in individual Study Plan. 53 refs., 54 figs., 24 tabs

  16. Probability distribution of pitting corrosion depth and rate in underground pipelines: A Monte Carlo study

    International Nuclear Information System (INIS)

    Caleyo, F.; Velazquez, J.C.; Valor, A.; Hallen, J.M.

    2009-01-01

    The probability distributions of external-corrosion pit depth and pit growth rate were investigated in underground pipelines using Monte Carlo simulations. The study combines a predictive pit growth model developed by the authors with the observed distributions of the model variables in a range of soils. Depending on the pipeline age, any of the three maximal extreme value distributions, i.e. Weibull, Frechet or Gumbel, can arise as the best fit to the pitting depth and rate data. The Frechet distribution best fits the corrosion data for long exposure periods. This can be explained by considering the long-term stabilization of the diffusion-controlled pit growth. The findings of the study provide reliability analysts with accurate information regarding the stochastic characteristics of the pitting damage in underground pipelines.

  17. Probability distribution of pitting corrosion depth and rate in underground pipelines: A Monte Carlo study

    Energy Technology Data Exchange (ETDEWEB)

    Caleyo, F. [Departamento de Ingenieria Metalurgica, ESIQIE, IPN, UPALM Edif. 7, Zacatenco, 07738 Mexico, D.F. (Mexico)], E-mail: fcaleyo@gmail.com; Velazquez, J.C. [Departamento de Ingenieria Metalurgica, ESIQIE, IPN, UPALM Edif. 7, Zacatenco, 07738 Mexico, D.F. (Mexico); Valor, A. [Facultad de Fisica, Universidad de La Habana, San Lazaro y L, Vedado, 10400, La Habana (Cuba); Hallen, J.M. [Departamento de Ingenieria Metalurgica, ESIQIE, IPN, UPALM Edif. 7, Zacatenco, 07738 Mexico, D.F. (Mexico)

    2009-09-15

    The probability distributions of external-corrosion pit depth and pit growth rate were investigated in underground pipelines using Monte Carlo simulations. The study combines a predictive pit growth model developed by the authors with the observed distributions of the model variables in a range of soils. Depending on the pipeline age, any of the three maximal extreme value distributions, i.e. Weibull, Frechet or Gumbel, can arise as the best fit to the pitting depth and rate data. The Frechet distribution best fits the corrosion data for long exposure periods. This can be explained by considering the long-term stabilization of the diffusion-controlled pit growth. The findings of the study provide reliability analysts with accurate information regarding the stochastic characteristics of the pitting damage in underground pipelines.

  18. Skull penetrating wound

    International Nuclear Information System (INIS)

    Gonzalez Orlandi, Yvei; Junco Martin, Reinel; Rojas Manresa, Jorge; Duboy Limonta, Victor; Matos Herrera, Omar; Saez Corvo, Yunet

    2011-01-01

    The cranioencephalic trauma is common in the emergence centers to care for patients with multiple traumata and it becames in a health problem in many countries. Skull penetrating trauma is located in a special place due to its low frequency. In present paper a case of male patient aged 52 severely skull-injured with penetrating wound caused by a cold steel that remained introduced into the left frontotemporal region. After an imaging study the emergence surgical treatment was applied and patient evolves adequately after 25 days of hospitalization. Nowadays, she is under rehabilitation treatment due to a residual right hemiparesis.(author)

  19. The study of coastal groundwater depth and salinity variation using time-series analysis

    International Nuclear Information System (INIS)

    Tularam, G.A.; Keeler, H.P.

    2006-01-01

    A time-series approach is applied to study and model tidal intrusion into coastal aquifers. The authors examine the effect of tidal behaviour on groundwater level and salinity intrusion for the coastal Brisbane region using auto-correlation and spectral analyses. The results show a close relationship between tidal behaviour, groundwater depth and salinity levels for the Brisbane coast. The known effect can be quantified and incorporated into new models in order to more accurately map salinity intrusion into coastal groundwater table

  20. Magnetometry and Ground-Penetrating Radar Studies in the Sihuas Valley, Peru

    Science.gov (United States)

    Wisnicki, E.; Papadimitrios, K.; Bank, C.

    2013-12-01

    The Quillcapampa la Antigua site in Peru's Sihuas Valley is a settlement from Peru's Middle Horizon (600-100 A.D.). Archaeological interest in the area stems from the question of whether ancient civilizations were able to have extensive state control of distant groups, or whether state influence occurred through less direct ties (e.g., marriage, religion, or trade). Our geophysical surveys are preliminary to archaeological digging in the area. Ground-penetrating radar and magnetometry attempt to locate areas of interest for focused archaeological excavation, characterize the design of architectural remains and burial mounds in the area, and allow archaeologists to interpret the amount of influence the Wari civilization had on the local residents.

  1. A Monte Carlo study of the acceptance to scattered events in a depth encoding PET camera

    International Nuclear Information System (INIS)

    Moisan, C.; Tupper, P.; Rogers, J.G.; DeJong, J.K.

    1995-10-01

    We present a Monte Carlo study of acceptance to scattered events in a Depth Encoding Large Aperture Camera (DELAC), a hypothetical PET scanner with the capacity to encode the depth-of-interaction (DOI) of incident γ-rays. The simulation is initially validated against the measured energy resolution and scatter fraction of the ECAT-953B scanner. It is then used to assess the response to scattered events in a PET camera made of position encoding blocks of the EXACT HR PLUS type, modified to have DOI resolution through a variation in the photopeak pulse height. The detection efficiency for 511 keV γ-rays, as well as for those that scattered in the object or left only part of their energy in the block, is studied for several combinations of DOI sensitivities and block thicknesses. The scatter fraction predicted by the simulation for DELACs of various ring radii is compared to that of the ECAT-953B as a function of the energy threshold. The results indicate that the poorer discrimination of object scatters with depth sensitive blocks does not lead to a dramatic increase of the scatter fraction. (author). 10 refs., 1 tab., 5 figs

  2. A study on 210Po activity concentration in soil at different depths along coastal Kerala

    International Nuclear Information System (INIS)

    Primal D'Cunha; Sathyanarayana Bhat, P.; Narayana, Y.

    2011-01-01

    The paper presents systematic studies on the vertical profiles of 210 Po, an important decay product of 238 U, in soils along coastal Kerala. Soil samples collected from different depth intervals 0-10, 10-20, 20-30 cm were analyzed for 210 Po activity concentration by radiochemical methods. The activity 210 Po in soil samples were counted using a ZnS(Ag) alpha scintillation counting system. The mean values of activity concentrations of 210 Po in soil of various depths were found to be 8.66, 5.63 and 4.95 Bq kg -1 for depth intervals of 0-10, 10-20 and 20-30 cm, respectively. The overall activity concentration of 210 Po in soil was found to vary from 2.26 ± 0.19 to 14.02 ± 0.12 Bq kg -1 with a mean value of 6.43 Bq kg -1 . Maximum activity concentration was found in soil samples of Kollam region with the mean value of 10.08 ± 0.92 Bq kg -1 . The activity of 210 Po was found to be comparatively high in surface soil. The variation of 210 Po activity concentration with organic matter contents was studied. 210 Polonium activity concentration was found to increase with increasing organic matter content. (author)

  3. Ground penetrating radar geologic field studies of the ejecta of Barringer Meteorite Crater, Arizona, as a planetary analog

    Science.gov (United States)

    Russell, Patrick S.; Grant, John A.; Williams, Kevin K.; Carter, Lynn M.; Brent Garry, W.; Daubar, Ingrid J.

    2013-09-01

    penetrating radar (GPR) has been a useful geophysical tool in investigating a variety of shallow subsurface geological environments on Earth. Here we investigate the capabilities of GPR to provide useful geologic information in one of the most common geologic settings of planetary surfaces, impact crater ejecta. Three types of ejecta are surveyed with GPR at two wavelengths (400 MHz, 200 MHz) at Meteor Crater, Arizona, with the goal of capturing the GPR signature of the subsurface rock population. In order to "ground truth" the GPR characterization, subsurface rocks are visually counted and measured in preexisting subsurface exposures immediately adjacent to and below the GPR transect. The rock size-frequency distribution from 10 to 50 cm based on visual counts is well described by both power law and exponential functions, the former slightly better, reflecting the control of fragmentation processes during the impact-ejection event. GPR counts are found to overestimate the number of subsurface rocks in the upper meter (by a factor of 2-3x) and underestimate in the second meter of depth (0.6-1.0x), results attributable to the highly scattering nature of blocky ejecta. Overturned ejecta that is fractured yet in which fragments are minimally displaced from their complement fragments produces fewer GPR returns than well-mixed ejecta. The use of two wavelengths and division of results into multiple depth zones provides multiple aspects by which to characterize the ejecta block population. Remote GPR measurement of subsurface ejecta in future planetary situations with no subsurface exposure can be used to characterize those rock populations relative to that of Meteor Crater.

  4. Study on dinamic behavior and least burying depth of underground protective pipe

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Tetsuyuki; Kokusyo, Goji; Tanaka, Yukihisa; Kobayashi, Seiichi

    1988-03-30

    Effect of unit load per travel wheel on the protective pipe was studied when electricity cable distribution lines were buried in the depth less than the present standard for electric equipment, and logical burying depth was investigated. Test items were material test of the protective pipe, indoor load test, and field test at loamy ground. Impact resistance hard PVC pipe was used as the protective pipe, and its strength and elastic modulus were measured. Along with these tests, it was confirmed that there was no problem of cracking by repeated flattening or breakage by fatigue. By indoor test, it was observed that, in case of shallow burying, creap deformation was small, stress concentrate occured at the middle of axial direction, and that flattening ratio was seriously affected by the method of backfilling. Field test was conducted by applying the static load of a 20 ton dump truck, and the deformation, stress, and subsidence of the protective pipe, were measured. As the conclusion of those experiments, it was found that burying of protective pipe in the depth of not less than 30 cm is allowable, as long as sufficient bakfilling is made. (14 figs, 3 tabs, 3 refs)

  5. Miniature Ground Penetrating Radar, CRUX GPR

    Science.gov (United States)

    Kim, Soon Sam; Carnes, Steven R.; Haldemann, Albert F.; Ulmer, Christopher T.; Ng, Eddie; Arcone, Steven A.

    2006-01-01

    Under NASA instrument development programs (PIDDP 2000-2002, MIPD 2003-2005, ESR and T, 2005) we have been developing miniature ground penetrating radars (GPR) for use in mapping subsurface stratigraphy from planetary rovers for Mars and lunar applications. The Mars GPR is for deeper penetration (up to 50 m depth) into the Martian subsurface at moderate resolution (0.5 m) for a geological characterization. As a part of the CRUX (Construction and Resource Utilization Explorer) instrument suite, the CRUX GPR is optimized for a lunar prospecting application. It will have shallower penetration (5 m depth) with higher resolution (10 cm) for construction operations including ISRU (in-situ resource utilization).

  6. Sphere impact and penetration into wet sand

    KAUST Repository

    Marston, J. O.

    2012-08-07

    We present experimental results for the penetration of a solid sphere when released onto wet sand. We show, by measuring the final penetration depth, that the cohesion induced by the water can result in either a deeper or shallower penetration for a given release height compared to dry granular material. Thus the presence of water can either lubricate or stiffen the granular material. By assuming the shear rate is proportional to the impact velocity and using the depth-averaged stopping force in calculating the shear stress, we derive effective viscosities for the wet granular materials.

  7. Sphere impact and penetration into wet sand

    KAUST Repository

    Marston, J. O.; Vakarelski, Ivan Uriev; Thoroddsen, Sigurdur T

    2012-01-01

    We present experimental results for the penetration of a solid sphere when released onto wet sand. We show, by measuring the final penetration depth, that the cohesion induced by the water can result in either a deeper or shallower penetration for a given release height compared to dry granular material. Thus the presence of water can either lubricate or stiffen the granular material. By assuming the shear rate is proportional to the impact velocity and using the depth-averaged stopping force in calculating the shear stress, we derive effective viscosities for the wet granular materials.

  8. Studying unsaturated epikarst water storage properties by time lapse surface to depth gravity measurements

    Science.gov (United States)

    Deville, S.; Champollion, C.; chery, J.; Doerflinger, E.; Le Moigne, N.; Bayer, R.; Vernant, P.

    2011-12-01

    The assessment of water storage in the unsaturated zone in karstic areas is particularly challenging. Indeed, water flow path and water storage occur in quite heterogeneous ways through small scale porosity, fractures, joints and large voids. Due to this large heterogeneity, it is therefore difficult to estimate the amount of water circulating in the vadose zone by hydrological means. One indirect method consists to measure the gravity variation associated to water storage and withdrawal. Here, we apply a gravimetric method in which the gravity is measured at the surface and at depth on different sites. Then the time variations of the surface to depth (STD) gravity differences are compared for each site. In this study we attempt to evaluate the magnitude of epikarstic water storage variation in various karst settings using a CG5 portable gravimeter. Surface to depth gravity measurements are performed two times a year since 2009 at the surface an inside caves at different depths on three karst aquifers in southern France : 1. A limestone site on the Larzac plateau with a vadose zone thickness of 300m On this site measurements are done on five locations at different depths going from 0 to 50 m; 2. A dolomitic site on the Larzac plateau (Durzon karst aquifer) with a vadose zone thickness of 200m; Measurements are taken at the surface and at 60m depth 3. A limestone site on the Hortus karst aquifer and "Larzac Septentrional karst aquifer") with a vadose zone thickness of only 35m. Measurements are taken at the surface and at 30m depth Therefore, our measurements are used in two ways : First, the STD differences between dry and wet seasons are used to estimate the capacity of differential storage of each aquifer. Surprisingly, the differential storage capacity of all the sites is relatively invariant despite their variable geological of hydrological contexts. Moreover, the STD gravity variations on site 1 show that no water storage variation occurs beneath 10m depth

  9. Experimental Study of Leaching and Penetration of Nitrite ions in Nitrite-type Repair Materials on the Surface of Concrete

    Directory of Open Access Journals (Sweden)

    Masumi Inoue

    2017-01-01

    Full Text Available This study aimed to clarify the leaching properties of nitrite ions in nitrite-type repair materials exposed to rainfall. Repaired concrete specimens were prepared for leaching tests using a lithium nitrite solution, and the amounts of leaching and penetration of nitrite ions were measured under simulated rainfall. The results demonstrated that the amount of leaching could be controlled by using polymer cement paste and mortar surface coatings containing lithium nitrite solution, and by using polymer cement mortar surface coatings following direct lithium nitrite solution coatings. Furthermore, the amount of nitrite ion leaching in all cases was lower than the discharge standard value established by the water pollution control law.

  10. An in-depth analysis of theoretical frameworks for the study of care coordination

    Directory of Open Access Journals (Sweden)

    Sabine Van Houdt

    2013-06-01

    Full Text Available Introduction: Complex chronic conditions often require long-term care from various healthcare professionals. Thus, maintaining quality care requires care coordination. Concepts for the study of care coordination require clarification to develop, study and evaluate coordination strategies. In 2007, the Agency for Healthcare Research and Quality defined care coordination and proposed five theoretical frameworks for exploring care coordination. This study aimed to update current theoretical frameworks and clarify key concepts related to care coordination. Methods: We performed a literature review to update existing theoretical frameworks. An in-depth analysis of these theoretical frameworks was conducted to formulate key concepts related to care coordination.Results: Our literature review found seven previously unidentified theoretical frameworks for studying care coordination. The in-depth analysis identified fourteen key concepts that the theoretical frameworks addressed. These were ‘external factors’, ‘structure’, ‘tasks characteristics’, ‘cultural factors’, ‘knowledge and technology’, ‘need for coordination’, ‘administrative operational processes’, ‘exchange of information’, ‘goals’, ‘roles’, ‘quality of relationship’, ‘patient outcome’, ‘team outcome’, and ‘(interorganizational outcome’.Conclusion: These 14 interrelated key concepts provide a base to develop or choose a framework for studying care coordination. The relational coordination theory and the multi-level framework are interesting as these are the most comprehensive.

  11. Performance of kevlar fibre-reinforced rubber composite armour against shaped-charge jet penetration

    OpenAIRE

    Zu,Xu-dong; Huang,Zheng-xiang; Zhai,Wen

    2015-01-01

    AbstractThe protective capability of the Kevlar fibre-reinforced rubber composite armour (KFRRCA) at different obliquities is studied using depth-of-penetration experiments method against a 56 mm-diameter standard-shaped charge. Efficiency factors are calculated to evaluate the protection capability of the KFRRCA at different obliquities. Meanwhile, an X-ray experiment is used to observe the deformation, fracture, and scatter of the shaped-charge jet as it penetrates the composite armour. Fin...

  12. Study the Effect of Intermittent and Continuous Ponding Depths by Using Different Heads to Leach Water

    OpenAIRE

    Nesrin J. AL-Mansori

    2018-01-01

    As results of using water for irrigated lands in a random manner in a time of shortage main water resources, Experimental work carried out to study the effect of continuous and intermittent ponding depth on the leaching processes. Sandy soil used, sourced from Hilla / Al-Jameeya, at Hilla city. Sieve analysis and hydrometer testing used to identify the properties of the soil. A model used with dimensions of 30, 30 and, 70 cm, with two different heads of water. Shatt-Al-Hilla River samples use...

  13. DENSITY AND PENETRATION INSURANCE ON ACCIDENT & HEALTH PREMIUMS IN FUTURE IMPLEMENTATION OF SOLVENCY II – EMPIRICAL STUDY

    Directory of Open Access Journals (Sweden)

    PODOABÃ LUCIA

    2015-04-01

    Full Text Available The purpose of this paper is to present an empirical study regarding density and penetrat ion on accident & health premiums. At the beginning, we have presented the motivations of this research, highlighting and explaining the specific factors which influence the density and insurance penetration. Implementation of Solvency Directive at European level, in the field of insurance is through specific consequences. The changes made to accounting legislation at national, European and international level, with consequences on specific information presented in the financial statements of insurance companies, was another reason of our research. The appearance of the IFRS 4 "Insurance contracts", followed by its evolution phases allowed the creation of XBRL's in as the international standard of publication, exchange and financial analysis of data reported . Also, we cannot forget that the legislative changes in accounting have interesting consequences on economic risk management specific to this field, in terms of huge efforts from national and European supervisory authorities to control and prevent the ban kruptcy of its firms. For planning and implementation of supervisors’ measures, the important tasks were established by the quantitative impact studies, the stress tests and the analyses of different scenarios, all performed in insurance companies. Thus, w e conduct an analysis on a sample of 32 countries and a horizon of 10 years (2004 -2013, being tested 2 linear regression models. The results will confirm the link between level of economic development and accident & health insurance activity, but exclude the relationship between penetration factor and this type of insurance

  14. Ethical hacking and penetration testing guide

    CERN Document Server

    Baloch, Rafay

    2014-01-01

    Requiring no prior hacking experience, Ethical Hacking and Penetration Testing Guide supplies a complete introduction to the steps required to complete a penetration test, or ethical hack, from beginning to end. You will learn how to properly utilize and interpret the results of modern-day hacking tools, which are required to complete a penetration test. The book covers a wide range of tools, including Backtrack Linux, Google reconnaissance, MetaGooFil, dig, Nmap, Nessus, Metasploit, Fast Track Autopwn, Netcat, and Hacker Defender rootkit. Supplying a simple and clean explanation of how to effectively utilize these tools, it details a four-step methodology for conducting an effective penetration test or hack.Providing an accessible introduction to penetration testing and hacking, the book supplies you with a fundamental understanding of offensive security. After completing the book you will be prepared to take on in-depth and advanced topics in hacking and penetration testing. The book walks you through each ...

  15. Penetration route of functional molecules in stratum corneum studied by time-resolved small- and wide-angle x-ray diffraction

    International Nuclear Information System (INIS)

    Hatta, Ichiro; Ohta, Noboru; Yagi, Naoto; Nakazawa, Hiromitsu; Obata, Yasuko; Inoue, Katsuaki

    2011-01-01

    We studied effects of functional molecules on corneocytes in stratum corneum using time-resolved small- and wide-angle x-ray diffraction after applying a functional molecule. From these results it was revealed that in the stratum corneum a typical hydrophilic molecule, ethanol, penetrates via the transcellular route and on the other hand a typical hydrophobic molecule, d-limonene, penetrates via the intercellular route.

  16. Impact Study of PMSG-Based Wind Power Penetration on Power System Transient Stability Using EEAC Theory

    Directory of Open Access Journals (Sweden)

    Zhongyi Liu

    2015-11-01

    Full Text Available Wind turbines with direct-driven permanent magnet synchronous generators (PMSGs are widely used in wind power generation. According to the dynamic characteristics of PMSGs, an impact analysis of PMSG-based wind power penetration on the transient stability of multi-machine power systems is carried out in this paper based on the theory of extended equal area criterion (EEAC. Considering the most severe PMSG integration situation, the changes in the system’s equivalent power-angle relationships after integrating PMSGs are studied in detail. The system’s equivalent mechanical input power and the fault period electrical output power curves are found to be mainly affected. The analysis demonstrates that the integration of PMSGs can cause either detrimental or beneficial effects on the system transient stability. It is determined by several factors, including the selection of the synchronous generators used to balance wind power, the reactive power control mode of PMSGs and the wind power penetration level. Two different simulation systems are also adopted to verify the analysis results.

  17. Validation and Algorithms Comparative Study for Microwave Remote Sensing of Snow Depth over China

    International Nuclear Information System (INIS)

    Bin, C J; Qiu, Y B; Shi, L J

    2014-01-01

    In this study, five different snow algorithms (Chang algorithm, GSFC 96 algorithm, AMSR-E SWE algorithm, Improved Tibetan Plateau algorithm and Savoie algorithm) were selected to validate the accuracy of snow algorithms over China. These algorithms were compared for the accuracy of snow depth algorithms with AMSR-E brightness temperature data and ground measurements on February 10-12, 2010. Results showed that the GSFC 96 algorithm was more suitable in Xinjiang with the RMSE range from 6.85cm to 7.48 cm; in Inner Mongolia and Northeast China. Improved Tibetan Plateau algorithm is superior to the other four algorithms with the RMSE of 5.46cm∼6.11cm and 6.21cm∼7.83cm respectively; due to the lack of ground measurements, we couldn't get valid statistical results over the Tibetan Plateau. However, the mean relative error (MRE) of the selected algorithms was ranging from 37.95% to 189.13% in four study areas, which showed that the accuracy of the five snow depth algorithms is limited over China

  18. False recognition depends on depth of prior word processing: a magnetoencephalographic (MEG) study.

    Science.gov (United States)

    Walla, P; Hufnagl, B; Lindinger, G; Deecke, L; Imhof, H; Lang, W

    2001-04-01

    Brain activity was measured with a whole head magnetoencephalograph (MEG) during the test phases of word recognition experiments. Healthy young subjects had to discriminate between previously presented and new words. During prior study phases two different levels of word processing were provided according to two different kinds of instructions (shallow and deep encoding). Event-related fields (ERFs) associated with falsely recognized words (false alarms) were found to depend on the depth of processing during the prior study phase. False alarms elicited higher brain activity (as reflected by dipole strength) in case of prior deep encoding as compared to shallow encoding between 300 and 500 ms after stimulus onset at temporal brain areas. Between 500 and 700 ms we found evidence for differences in the involvement of neural structures related to both conditions of false alarms. Furthermore, the number of false alarms was found to depend on depth of processing. Shallow encoding led to a higher number of false alarms than deep encoding. All data are discussed as strong support for the ideas that a certain level of word processing is performed by a distinct set of neural systems and that the same neural systems which encode information are reactivated during the retrieval.

  19. Deep penetration of light into biotissue

    Science.gov (United States)

    Bearden, Edward D.; Wilson, James D.; Zharov, Vladimir P.; Lowery, Curtis L.

    2001-07-01

    The results of a study of deep (several centimeters) light penetration into biological tissue are presented in order to estimate its significance to potentially photosensitive structures and processes including the fetal eyes. In order to accomplish this goal, samples of various tissues (fat, muscle, and uterus) from surgical patients and autopsies were examined with a double integrating sphere arrangement to determine their optical properties. The results were implemented in a Monte Carlo modeling program. Next, optical fiber probes were inserted into the uterus and abdominal wall of patients undergoing laparoscopic procedures. The fibers were couples to a photomultiplier tube with intervening filters allowing measurements of light penetration at various wavelengths. To determine the feasibility of stimulation in utero, a xenon lamp and waveguide were used to transilluminate the abdomen of several labor patients. Light in the range of 630 to 670 nm where the eye sensitivity and penetration depth are well matched, will likely provide the best chance of visual stimulation. Fetal heart rate, fetal movement, and fetal magnetoencephalography (SQUID) and electroencephalography (EEG) were observed in different studies to determine if stimulation has occurred. Since internal organs and the fetus are completely dark adapted, the amount of light required to simulate in our opinion could be on the order of 10(superscript -8 Watts.

  20. Real-Time Penetrating Particle Analyzer (PAN)

    Science.gov (United States)

    Wu, X.; Ambrosi, G.; Bertucci, B.

    2018-02-01

    The PAN can measure penetrating particles with great precision to study energetic particles, solar activities, and the origin and propagation of cosmic rays. The real-time monitoring of penetrating particles is crucial for deep space human travel.

  1. Storage Conditions of Skin Affect Tissue Structure and Subsequent in vitro Percutaneous Penetration

    DEFF Research Database (Denmark)

    Nielsen, Jesper Bo; Plasencia Gil, Maria Inés; Sørensen, Jens Ahm

    2011-01-01

    fluorescence microscopy) and in vitro percutaneous penetration of caffeine under four different storage conditions using skin samples from the same donors: fresh skin, skin kept at -20°C for 3 weeks (with or without the use of polyethylene glycol) and at -80°C. Our results show a correlation between increasing...... permeation of caffeine and tissue structural damage caused by the storage conditions, most so after skin storage at -80°C. The presented approach, which combines imaging techniques with studies on percutaneous penetration, enables the link between tissue damage at selected depths and penetration...

  2. High-velocity Penetration of Concrete Targets with Three Types of Projectiles: Experiments and Analysis

    Directory of Open Access Journals (Sweden)

    Shuang Zhang

    Full Text Available Abstract This study conducted high-velocity penetration experiments using conventional ogive-nose, double-ogive-nose, and grooved-tapered projectiles of approximately 2.5 kg and initial velocities between 1000 and 1360 m/s to penetrate or perforate concrete targets with unconfined compressive strengths of nominally 40MPa. The penetration performance data of these three types of projectiles with two different types of materials (i.e., AerMet100 and DT300 were obtained. The crater depth model considering both the projectile mass and the initial velocity was proposed based on the test results and a theoretical analysis. The penetration ability and the trajectory stability of these three projectile types were compared and analyzed accordingly. The results showed that, under these experimental conditions, the effects of these two different kinds of projectile materials on the penetration depth and mass erosion rate of projectile were not obvious. The existing models could not reflect the crater depths for projectiles of greater weights or higher velocities, whereas the new model established in this study was reliable. The double-ogive-nose has a certain effect of drag reduction. Thus, the double-ogive-nose projectile has a higher penetration ability than the conventional ogive-nose projectile. Meanwhile, the grooved-tapered projectile has a better trajectory stability, because the convex parts of tapered shank generated the restoring moment to stabilize the trajectory.

  3. Influence of the mole penetrator on measurements of heat flow in lunar subsurface layers

    Science.gov (United States)

    Wawrzaszek, Roman; Drogosz, Michal; Seweryn, Karol; Banaszkiewicz, Marek; Grygorczuk, Jerzy

    Measuring the thermal gradient in subsurface layers is a basic method of determination the heat flux from the interior of a planetary body to its surface. In case of the Moon, such measurements complemented with the results of theoretical analysis and modeling can significantly improve our understanding of the thermal and geological evolution of the Moon. In practice, temperature gradient measurements are performed by at least two sensors located at different depths under the surface. These sensors will be attached to a penetrator [1] or to a cable pulled behind the penetrator. In both cases the object that carries the sensors, e.g. penetrator, perturb temperature measurements. In our study we analyze a case of two thermal sensors attached to the ends of 350mm long penetrator made of a composite material. In agreement with the studies of other authors we have found that the penetrator should be placed at the depth of 2-3 meters, where periodic changes of the temperature due to variation of solar flux at the surface are significantly smaller than the error of temperature measurement. The most important result of our analysis is to show how to deconvolve the real gradient of the temperature from the measurements perturbed by the penetrator body. In this way it will be possible to more accurately determine heat flux in the lunar regolith. [1] Grygorczuk J., Seweryn K., Wawrzaszek R., Banaszkiewicz M., Insertion of a Mole Pene-trator -Experimental Results, /39th Lunar and Planetary Science Conference /League City, Texas 2008

  4. Ground-penetrating radar study of the Cena Bog, Latvia: linkage of reflections with peat moisture content

    Directory of Open Access Journals (Sweden)

    Karušs, J.

    2015-12-01

    Full Text Available Present work illustrates results of the ground-penetrating radar (GPR study of the Cena Bog, Latvia. Six sub-horizontal reflections that most probably correspond to boundaries between sediments with different electromagnetic properties were identified. One of the reflections corresponds to bog peat mineral bottom interface but the rest are linked to boundaries within the peat body. The radar profiles are incorporated with sediment cores and studies of peat moisture and ash content, and degree of decomposition. Most of the electromagnetic wave reflections are related to changes in peat moisture content. The obtained data show that peat moisture content changes of at least 3 % are required to cause GPR signal reflection. However, there exist reflections that do not correlate with peat moisture content. As a result, authors disagree with a dominant opinion that all reflections in bogs are solely due to changes in volumetric peat moisture content.

  5. Study on production mechanism of welding residual stress at the juncture of a pipe penetrating a thick plate

    International Nuclear Information System (INIS)

    Mochizuki, Masahito; Enomoto, Kunio; Okamoto, Noriaki; Saitoh, Hideyo; Hayashi, Eisaku.

    1994-01-01

    This paper studies welding residual stresses at the intersection of a small diameter pipe penetrating a thick plate. The pipe is welded to the plate, and Tungsten Innert Gas (TIG) cladding is melted on the inner surface of the pipe to protect it from stress corrosion cracking due to long operation in nuclear power plants. Stresses are calculated by heat conduction analysis and thermal elasto-plastic analysis, and also measured by strain gauges. Welding residual stresses are shown to have no corrosive influence on the inner pipe surface, and the stresses are compressed enough to protect the pipe against stress corrosion cracking on the outer surface. It was also studied to make clear the production mechanism of the residual stresses which were generated by welding processes at the pipe. (author)

  6. Essential oil from Zanthoxylum bungeanum Maxim. and its main components used as transdermal penetration enhancers: a comparative study.

    Science.gov (United States)

    Lan, Yi; Li, Hui; Chen, Yan-yan; Zhang, Ye-wen; Liu, Na; Zhang, Qing; Wu, Qing

    2014-11-01

    Our previous studies had confirmed that the essential oil from Zanthoxylum bungeanum Maxim. (Z. bungeanum oil) could effectively enhance the percutaneous permeation of drug molecules as a natural transdermal penetration enhancer. The aim of the present study is to investigate and compare the skin penetration enhancement effect of Z. bungeanum oil and its main components on traditional Chinese medicine (TCM) active components. Toxicities of Z. bungeanum oil and three selected terpene compounds (terpinen-4-ol, 1,8-cineole, and limonene) in epidermal keratinocytes (HaCaT) and dermal fibroblast (CCC-ESF-1) cell lines were measured using an MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay. Five model drugs in TCM external preparations, namely osthole (OT), tetramethylpyrazine (TMP), ferulic acid (FA), puerarin (PR), and geniposide (GP), which were selected based on their lipophilicity denoted by logKo/w, were tested using in vitro permeation studies in which vertical Franz diffusion cells and rat abdominal skin were employed. The secondary structure changes of skin stratum corneum (SC) and drug thermodynamic activities were investigated to understand their mechanisms of action using Fourier transform infrared (FTIR) spectroscopy and saturation solubility studies, respectively. It was found that Z. bungeanum oil showed lower toxicities in both HaCaT cells and CCC-ESF-1 cells compared with three terpene compounds used alone. The enhancement permeation capacities by all tested agents were in the following increasing order: terpinen-4-ol≈1,8-cineole

  7. A Mass Loss Penetration Model to Investigate the Dynamic Response of a Projectile Penetrating Concrete considering Mass Abrasion

    Directory of Open Access Journals (Sweden)

    NianSong Zhang

    2015-01-01

    Full Text Available A study on the dynamic response of a projectile penetrating concrete is conducted. The evolutional process of projectile mass loss and the effect of mass loss on penetration resistance are investigated using theoretical methods. A projectile penetration model considering projectile mass loss is established in three stages, namely, cratering phase, mass loss penetration phase, and remainder rigid projectile penetration phase.

  8. What Motivates Student Environmental Activists on College Campuses? An In-Depth Qualitative Study

    Directory of Open Access Journals (Sweden)

    Cadi Y. Fung

    2017-11-01

    Full Text Available Public concern for the natural environment continues to grow as complex environmental problems emerge. One avenue where concern for the environment has been expressed is through activism. However, research on environmental activism, often aimed at understanding the motivations behind activist behavior, has largely focused on older adults. In this study, we extend the state of knowledge on environmental activism further by focusing on college students. We use qualitative methods (in-depth interviews and observations to examine the motivations behind student involvement in environmental activism on a state university campus. Our findings underscore that young people’s activist motivations are not stand-alone phenomena; they work in tandem with other processes and factors in a dynamic way and are influenced by an individual’s history, previous experiences and passion, a sense of community, existing incentives, and self-satisfaction derived from activist behavior.

  9. Study on the Depth, Rate, Shape, and Strength of Pulse with Cardiovascular Simulator

    Directory of Open Access Journals (Sweden)

    Ju-Yeon Lee

    2017-01-01

    Full Text Available Pulse diagnosis is important in oriental medicine. The purpose of this study is explaining the mechanisms of pulse with a cardiovascular simulator. The simulator is comprised of the pulse generating part, the vessel part, and the measurement part. The pulse generating part was composed of motor, slider-crank mechanism, and piston pump. The vessel part, which was composed with the aorta and a radial artery, was fabricated with silicon to implement pulse wave propagation. The pulse parameters, such as the depth, rate, shape, and strength, were simulated. With changing the mean pressure, the floating pulse and the sunken pulse were generated. The change of heart rate generated the slow pulse and the rapid pulse. The control of the superposition time of the reflected wave generated the string-like pulse and the slippery pulse. With changing the pulse pressure, the vacuous pulse and the replete pulse were generated. The generated pulses showed good agreements with the typical pulses.

  10. Computational study of depth completion consistent with human bi-stable perception for ambiguous figures.

    Science.gov (United States)

    Mitsukura, Eiichi; Satoh, Shunji

    2018-03-01

    We propose a computational model that is consistent with human perception of depth in "ambiguous regions," in which no binocular disparity exists. Results obtained from our model reveal a new characteristic of depth perception. Random dot stereograms (RDS) are often used as examples because RDS provides sufficient disparity for depth calculation. A simple question confronts us: "How can we estimate the depth of a no-texture image region, such as one on white paper?" In such ambiguous regions, mathematical solutions related to binocular disparities are not unique or indefinite. We examine a mathematical description of depth completion that is consistent with human perception of depth for ambiguous regions. Using computer simulation, we demonstrate that resultant depth-maps qualitatively reproduce human depth perception of two kinds. The resultant depth maps produced using our model depend on the initial depth in the ambiguous region. Considering this dependence from psychological viewpoints, we conjecture that humans perceive completed surfaces that are affected by prior-stimuli corresponding to the initial condition of depth. We conducted psychological experiments to verify the model prediction. An ambiguous stimulus was presented after a prior stimulus removed ambiguity. The inter-stimulus interval (ISI) was inserted between the prior stimulus and post-stimulus. Results show that correlation of perception between the prior stimulus and post-stimulus depends on the ISI duration. Correlation is positive, negative, and nearly zero in the respective cases of short (0-200 ms), medium (200-400 ms), and long ISI (>400 ms). Furthermore, based on our model, we propose a computational model that can explain the dependence. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Electrophysiological evidence for the modulation of retrieval orientation by depth of study processing.

    Science.gov (United States)

    Rugg, M D; Allan, K; Birch, C S

    2000-07-01

    Event-related potentials (ERPs) were employed to investigate whether brain activity elicited by retrieval cues in a memory test varies according to the encoding task undertaken at study. Two recognition memory test blocks were administered, preceded, in one case, by a "shallow" study task (alphabetic judgement) and, in the other case, by a "deep" task (sentence generation). ERPs elicited by the new words in each test block differed, the ERPs elicited in the block following the shallow study task exhibiting the more positive-going waveforms. This finding was taken as evidence that subjects adopt different "retrieval sets" when attempting to retrieve items that had been encoded in terms of alphabetic versus semantic attributes. Differences between the ERPs elicited by correctly classified old and new words (old/new effects) also varied with encoding task. The effects for deeply studied words resembled those found in previous ERP studies of recognition memory, whereas old/new effects for shallowly studied words were confined to a late-onsetting, right frontal positivity. Together, the findings indicate that the depth of study processing influences two kinds of memory-related neural activity, associated with memory search operations, and the processing of retrieved information, respectively.

  12. Ethical Dilemmas and Dimensions in Penetration Testing

    OpenAIRE

    Faily, Shamal; McAlaney, John; Iacob, C.

    2015-01-01

    Penetration testers are required to attack systems to evaluate their security, but without engaging in unethical behaviour while doing so. Despite work on hacker values and studies into security practice, there is little literature devoted to the ethical pressures associated with penetration testing. This paper presents several ethical dilemmas and dimensions associated with penetration testing;\\ud these shed light on the ethical positions taken by Penetration testers, and help identify poten...

  13. A new polarized neutrons method for studying depth-inhomogeneously magnetized magnetic films

    International Nuclear Information System (INIS)

    Korneev, D.A.

    1990-01-01

    The main specific features of the process of polarized thermal neutrons specular reflection from the surface of depth-inhomogeneously magnetic films are considered theoretically. It is shown how using the method of specular reflection of polarized thermal neutrons from such a films surface, one may restore the depth distribution of the local magnetization vector M-vector(z). 9 refs

  14. Depth perception in frogs and toads a study in neural computing

    CERN Document Server

    House, Donald

    1989-01-01

    Depth Perception in Frogs and Toads provides a comprehensive exploration of the phenomenon of depth perception in frogs and toads, as seen from a neuro-computational point of view. Perhaps the most important feature of the book is the development and presentation of two neurally realizable depth perception algorithms that utilize both monocular and binocular depth cues in a cooperative fashion. One of these algorithms is specialized for computation of depth maps for navigation, and the other for the selection and localization of a single prey for prey catching. The book is also unique in that it thoroughly reviews the known neuroanatomical, neurophysiological and behavioral data, and then synthesizes, organizes and interprets that information to explain a complex sensory-motor task. The book will be of special interest to that segment of the neural computing community interested in understanding natural neurocomputational structures, particularly to those working in perception and sensory-motor coordination. ...

  15. Measuring Compositions in Organic Depth Profiling: Results from a VAMAS Interlaboratory Study

    Energy Technology Data Exchange (ETDEWEB)

    Shard, A. G.; Havelund, Rasmus; Spencer, Steve J.; Gilmore, I. S.; Alexander, Morgan R.; Angerer, Tina B.; Aoyagi, Satoka; Barnes, Jean P.; Benayad, Anass; Bernasik, Andrzej; Ceccone, Giacomo; Counsell, Jonathan D.; Deeks, Christopher; Fletcher, John S.; Graham, Daniel J.; Heuser, Christian; Lee, Tae G.; Marie, Camille; Marzec, Mateusz M.; Mishra, Gautam; Rading, Derk; Renault, Oliver; Scurr, David J.; Shon, Hyun K.; Spampinato, Valentina; Tian, Hua; Wang, Fuyi; Winograd, Nicholas; Wu, Kui; Wucher, Andreas; Zhou, Yufan; Zhu, Zihua

    2015-07-23

    We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the measurement of composition in organic depth profiling. Layered samples with known binary compositions of Irganox 1010 and either Irganox 1098 or Fmoc-pentafluoro-L-phenylalanine in each layer were manufactured in a single batch and distributed to more than 20 participating laboratories. The samples were analyzed using argon cluster ion sputtering and either X-ray Photoelectron Spectroscopy (XPS) or Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) to generate depth profiles. Participants were asked to estimate the volume fractions in two of the layers and were provided with the compositions of all other layers. Participants using XPS provided volume fractions within 0.03 of the nominal values. Participants using ToF-SIMS either made no attempt, or used various methods that gave results ranging in error from 0.02 to over 0.10 in volume fraction, the latter representing a 50% relative error for a nominal volume fraction of 0.2. Error was predominantly caused by inadequacy in the ability to compensate for primary ion intensity variations and the matrix effect in SIMS. Matrix effects in these materials appear to be more pronounced as the number of atoms in both the primary analytical ion and the secondary ion increase. Using the participants’ data we show that organic SIMS matrix effects can be measured and are remarkably consistent between instruments. We provide recommendations for identifying and compensating for matrix effects. Finally we demonstrate, using a simple normalization method, that virtually all ToF-SIMS participants could have obtained estimates of volume fraction that were at least as accurate and consistent as XPS.

  16. Increasing adolescents' depth of understanding of cross-curriculum words: an intervention study.

    Science.gov (United States)

    Spencer, Sarah; Clegg, Judy; Lowe, Hilary; Stackhouse, Joy

    2017-09-01

    There is some evidence that vocabulary intervention is effective for children, although further research is needed to confirm the impact of intervention within contexts of social disadvantage. Very little is known about the effectiveness of interventions to increase adolescent knowledge of cross-curriculum words. To evaluate the effectiveness of an intervention programme designed to develop adolescents' knowledge of cross-curriculum words. Participants were 35 adolescents aged between 12 and 14 years who were at risk of educational underachievement with low scores on a range of assessments. Participants received a 10-week intervention programme in small groups, targeting 10 cross-curriculum words (e.g., 'summarize'). This was evaluated using a bespoke outcome measure (the Word Knowledge Profile). The study involved an AABA design, with a repeated baseline, delayed intervention cohort and blind assessment. Intervention included both semantic and phonological information about the target words and involved the adolescents using the words in multiple contexts. Results were promising and participants' knowledge of the targeted words significantly increased following intervention. Progress was demonstrated on the Word Knowledge Profile on the item requiring participants to define the word (for the summer intervention group only). This increase in depth of knowledge was seen on taught words but not on matched non-taught words. Cross-curriculum words are not consistently understood by adolescents at risk of low educational attainment within a low socio-economic context. A 10-week intervention programme resulted in some increases to the depth of knowledge of targeted cross-curriculum words. © 2017 Royal College of Speech and Language Therapists.

  17. Customized photorefractive keratectomy to correct high ametropia after penetrating keratoplasty: A pilot study

    Directory of Open Access Journals (Sweden)

    Giuseppe De Rosa

    2015-07-01

    Conclusion: Our pilot study suggests that customized PRK can be a safe and effective method for treating ametropia and irregular astigmatisms after PK. Future studies with larger samples and longer follow-ups should be performed to confirm these results.

  18. Determining global distribution of microplastics by combining citizen science and in-depth case studies.

    Science.gov (United States)

    Bosker, Thijs; Behrens, Paul; Vijver, Martina G

    2017-05-01

    Microplastics (microplastics levels. The difference in extraction procedures can especially impact study outcomes, making it difficult, and sometimes impossible, to directly compare results among studies. To address this, we recently developed a standard operating procedure (SOP) for sampling microplastics on beaches. We are now assessing regional and global variations in beach microplastics using this standardized approach for 2 research projects. Our first project involves the general public through citizen science. Participants collect sand samples from beaches using a basic protocol, and we subsequently extract and quantify microplastics in a central laboratory using the SOP. Presently, we have 80+ samples from around the world and expect this number to further increase. Second, we are conducting 2, in-depth, regional case studies: one along the Dutch coast (close to major rivers, a known source of microplastic input into marine systems), and the other on the Lesser Antilles in the Caribbean (in the proximity to a hotspot of plastics in the North Atlantic Ocean). In both projects, we use our new SOP to determine regional variation in microplastics, including differences in physicochemical characteristics such as size, shape, and polymer type. Our research will provide, for the first time, a systematic comparison on levels of microplastics on beaches at both a regional and global scale. Integr Environ Assess Manag 2017;13:536-541. © 2017 SETAC. © 2017 SETAC.

  19. The Gly2019Ser mutation in LRRK2 is not fully penetrant in familial Parkinson's disease: the GenePD study

    Directory of Open Access Journals (Sweden)

    Corbett Alastair

    2008-11-01

    Full Text Available Abstract Background We report age-dependent penetrance estimates for leucine-rich repeat kinase 2 (LRRK2-related Parkinson's disease (PD in a large sample of familial PD. The most frequently seen LRRK2 mutation, Gly2019Ser (G2019S, is associated with approximately 5 to 6% of familial PD cases and 1 to 2% of idiopathic cases, making it the most common known genetic cause of PD. Studies of the penetrance of LRRK2 mutations have produced a wide range of estimates, possibly due to differences in study design and recruitment, including in particular differences between samples of familial PD versus sporadic PD. Methods A sample, including 903 affected and 58 unaffected members from 509 families ascertained for having two or more PD-affected members, 126 randomly ascertained PD patients and 197 controls, was screened for five different LRRK2 mutations. Penetrance was estimated in families of LRRK2 carriers with consideration of the inherent bias towards increased penetrance in a familial sample. Results Thirty-one out of 509 families with multiple cases of PD (6.1% were found to have 58 LRRK2 mutation carriers (6.4%. Twenty-nine of the 31 families had G2019S mutations while two had R1441C mutations. No mutations were identified among controls or unaffected relatives of PD cases. Nine PD-affected relatives of G2019S carriers did not carry the LRRK2 mutation themselves. At the maximum observed age range of 90 to 94 years, the unbiased estimated penetrance was 67% for G2019S families, compared with a baseline PD risk of 17% seen in the non-LRRK2-related PD families. Conclusion Lifetime penetrance of LRRK2 estimated in the unascertained relatives of multiplex PD families is greater than that reported in studies of sporadically ascertained LRRK2 cases, suggesting that inherited susceptibility factors may modify the penetrance of LRRK2 mutations. In addition, the presence of nine PD phenocopies in the LRRK2 families suggests that these susceptibility

  20. FAA Fluorescent Penetrant Laboratory Inspections

    Energy Technology Data Exchange (ETDEWEB)

    WINDES,CONNOR L.; MOORE,DAVID G.

    2000-08-02

    The Federal Aviation Administration Airworthiness Assurance NDI Validation Center currently assesses the capability of various non-destructive inspection (NDI) methods used for analyzing aircraft components. The focus of one such exercise is to evaluate the sensitivity of fluorescent liquid penetrant inspection. A baseline procedure using the water-washable fluorescent penetrant method defines a foundation for comparing the brightness of low cycle fatigue cracks in titanium test panels. The analysis of deviations in the baseline procedure will determine an acceptable range of operation for the steps in the inspection process. The data also gives insight into the depth of each crack and which step(s) of the inspection process most affect penetrant sensitivities. A set of six low cycle fatigue cracks produced in 6.35-mm thick Ti-6Al-4V specimens was used to conduct the experiments to produce sensitivity data. The results will document the consistency of the crack readings and compare previous experiments to find the best parameters for water-washable penetrant.

  1. Effect of compressibility on the hypervelocity penetration

    Science.gov (United States)

    Song, W. J.; Chen, X. W.; Chen, P.

    2018-02-01

    We further consider the effect of rod strength by employing the compressible penetration model to study the effect of compressibility on hypervelocity penetration. Meanwhile, we define different instances of penetration efficiency in various modified models and compare these penetration efficiencies to identify the effects of different factors in the compressible model. To systematically discuss the effect of compressibility in different metallic rod-target combinations, we construct three cases, i.e., the penetrations by the more compressible rod into the less compressible target, rod into the analogously compressible target, and the less compressible rod into the more compressible target. The effects of volumetric strain, internal energy, and strength on the penetration efficiency are analyzed simultaneously. It indicates that the compressibility of the rod and target increases the pressure at the rod/target interface. The more compressible rod/target has larger volumetric strain and higher internal energy. Both the larger volumetric strain and higher strength enhance the penetration or anti-penetration ability. On the other hand, the higher internal energy weakens the penetration or anti-penetration ability. The two trends conflict, but the volumetric strain dominates in the variation of the penetration efficiency, which would not approach the hydrodynamic limit if the rod and target are not analogously compressible. However, if the compressibility of the rod and target is analogous, it has little effect on the penetration efficiency.

  2. In-depth study of personality disorders in first-admission patients with substance use disorders

    Directory of Open Access Journals (Sweden)

    Langås Anne-Marit

    2012-10-01

    Full Text Available Abstract Background Assessment of comorbid personality disorders (PDs in patients with substance use disorders (SUDs is challenging due to symptom overlap, additional mental and physical disorders, and limitations of the assessment methods. Our in-depth study applied methods to overcome these difficulties. Method A complete catchment area sample of 61 consecutively admitted patients with SUDs, with no previous history of specialized treatment (addiction clinics, psychiatry were studied, addressing PDs and associated clinical and demographic variables. The thorough assessments included the Psychiatric Research Interview for Substance and Mental Disorders and the Structured Clinical Interview for DSM-IV Axis II Personality Disorders. Results Forty-six percent of the SUD patients had at least one PD (16% antisocial [males only]; 13% borderline; and 8% paranoid, avoidant, and obsessive-compulsive, respectively. Cluster C disorders were as prevalent as Cluster B disorders. SUD patients with PDs were younger at the onset of their first SUD and at admission; used more illicit drugs; had more anxiety disorders, particularly social phobia; had more severe depressive symptoms; were more distressed; and less often attended work or school. Conclusion The psychiatric comorbidity and symptom load of SUD patients with PDs differed from those of SUD patients without PDs, suggesting different treatment needs, and stressing the value of the assessment of PDs in SUD patients.

  3. Speech Understanding with a New Implant Technology: A Comparative Study with a New Nonskin Penetrating Baha System

    OpenAIRE

    Kurz, Anja; Flynn, Mark; Caversaccio, Marco; Kompis, Martin

    2014-01-01

    Objective. To compare hearing and speech understanding between a new, nonskin penetrating Baha system (Baha Attract) to the current Baha system using a skin-penetrating abutment. Methods. Hearing and speech understanding were measured in 16 experienced Baha users. The transmission path via the abutment was compared to a simulated Baha Attract transmission path by attaching the implantable magnet to the abutment and then by adding a sample of artificial skin and the external parts of the Baha...

  4. Soil depth modelling using terrain analysis and satellite imagery: the case study of Qeshlaq mountainous watershed (Kurdistan, Iran

    Directory of Open Access Journals (Sweden)

    Salahudin Zahedi

    2017-09-01

    Full Text Available Soil depth is a major soil characteristic, which is commonly used in distributed hydrological modelling in order to present watershed subsurface attributes. This study aims at developing a statistical model for predicting the spatial pattern of soil depth over the mountainous watershed from environmental variables derived from a digital elevation model (DEM and remote sensing data. Among the explanatory variables used in the models, seven are derived from a 10 m resolution DEM, namely specific catchment area, wetness index, aspect, slope, plan curvature, elevation and sediment transport index. Three variables landuse, NDVI and pca1 are derived from Landsat8 imagery, and are used for predicting soil depth by the models. Soil attributes, soil moisture, topographic curvature, training samples for each landuse and major vegetation types are considered at 429 profiles within four subwatersheds. Random forests (RF, support vector machine (SVM and artificial neural network (ANN are used to predict soil depth using the explanatory variables. The models are run using 336 data points in the calibration dataset with all 31 explanatory variables, and soil depth as the response of the models. Mean decrease permutation accuracy is performed on Variable selection. Testing dataset is done with the model soil depth values at testing locations (93 points using different efficiency criteria. Prediction error is computed for both the calibration and testing datasets. Results show that the variables landuse, specific surface area, slope, pca1, NDVI and aspect are the most important explanatory variables in predicting soil depth. RF and SVM models are appropriate for the mountainous watershed areas that have been limited in the depth of the soil and ANN model is more suitable for watershed with the fields of agricultural and deep soil depth.

  5. Experimental and Numerical Study on the Dispersion Patterns and Penetration Properties of MEFP with Seven Arc-Cone Liners

    Directory of Open Access Journals (Sweden)

    JianFeng Liu

    Full Text Available Abstract A new MEFP warhead with seven arc-cone liners which can form 7, 13 or 19 penetrators at different standoffs is designed. Dispersion patterns and penetration properties of MEFP are performed on five #45 steel targets of dimension 160cm x 160cm x 1.5cm at various standoffs (45cm, 60cm, 80cm, 120cm, 170cm. It reaches the conclusion that every surrounding liner is broken into three penetrators during the formation process of MEFP and a group of aimable penetrators consisting a central projectile surrounded by 18 penetrators is finally formed. Maximum divergence angle of surrounding penetrator is 9.8° and the damage area reaches 0.37m2 at 1.7m. A nonlinear surface fitting about perforations information on the targets at different standoffs provides a method of predicting the dispersion patterns of MEFP. Once initiated, damage probability for defeating light armor of MEFP warhead with seven arc-cone liners is significantly improved and the results provide important reference to the design and optimization of MEFP warhead in engineering.

  6. Integration of wind power in the Danish generation system. EC wind power penetration study, phase 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-06-01

    The Commission of the European Communities has asked utilities in the member countries to carry out a coordinated study of the wind energy potential. The main objective is to show the consequences for the future electricity system when integrating wind power production covering 5, 10 or 15% of total demand. In addition to the best estimate scenario believed to be operational, some additional calculations have been carried out: wind power production as a negative load only (not operational for the total system); different levels of investment in wind farms. The methodology is based on the following steps: define a reference scenario for year 2000; define an alternative scenario with a certain amount of wind power production; calculate time-series for electrical load and district heating from combined heat/power production; calculate time-series for wind power production; make economic evaluation and sensitivity analysis; show environmental differences. Incorporation of wind power into the ELSAM power system, with the wind energy meeting, about 5% of demand will give rise to additional control capacity, or call for new contracts with neighbouring countries. The study includes estimated network investments. The simulations have been made with the SIM and SLUMP computer programmes. The economic analyses and the sensitivity analyses have been carried out using spreadsheets. The conclusion concerning profitability - based on the best estimate assumptions - is that the studied wind power scenarios are unprofitable. (EG)

  7. Depth Profiling (ICP-MS Study of Toxic Metal Buildup in Concrete Matrices: Potential Environmental Impact

    Directory of Open Access Journals (Sweden)

    Ghada Bassioni

    2010-10-01

    Full Text Available This paper explores the potential of concrete material to accumulate toxic trace elements using ablative laser technology (ICP-MS. Concrete existing in offshore structures submerged in seawater acts as a sink for hazardous metals, which could be gradually released into the ocean creating pollution and anoxic conditions for marine life. Ablative laser technology is a valuable tool for depth profiling concrete to evaluate the distribution of toxic metals and locate internal areas where such metals accumulate. Upon rapid degradation of concrete these “hotspots” could be suddenly released, thus posing a distinct threat to aquatic life. Our work simulated offshore drilling conditions by immersing concrete blocks in seawater and investigating accumulated toxic trace metals (As, Be, Cd, Hg, Os, Pb in cored samples by laser ablation. The experimental results showed distinct inhomogeneity in metal distribution. The data suggest that conditions within the concrete structure are favorable for random metal accumulation at certain points. The exact mechanism for this behavior is not clear at this stage and has considerable scope for extended research including modeling and remedial studies.

  8. Stochastic Optimization Model to STudy the Operational Impacts of High Wind Penetrations in Ireland

    DEFF Research Database (Denmark)

    Meibom, Peter; Barth, R.; Hasche, B.

    2011-01-01

    A stochastic mixed integer linear optimization scheduling model minimizing system operation costs and treating load and wind power production as stochastic inputs is presented. The schedules are updated in a rolling manner as more up-to-date information becomes available. This is a fundamental...... change relative to day-ahead unit commitment approaches. The need for reserves dependent on forecast horizon and share of wind power has been estimated with a statistical model combining load and wind power forecast errors with scenarios of forced outages. The model is used to study operational impacts...

  9. Effect of Maintaining Apical Patency on Irrigant Penetration into the Apical Two Millimeters of Large Root Canals : An In Vivo Study

    NARCIS (Netherlands)

    Vera, Jorge; Hernandez, Erick M.; Romero, Monica; Arias, Ana; van der Sluis, Lucas W. M.

    2012-01-01

    Introduction: Factors such as complex root canal anatomy and the vapor lock phenomenon have been shown to limit the penetration of irrigating solutions into the apical third in both in vivo and in vitro studies involving small and wide canals. Hence, the aim of this study was to determine whether

  10. Study on Chloride Ion Penetration Resistance of Rubberized Concrete Under Steady State Condition

    Directory of Open Access Journals (Sweden)

    Md Noor Nurazuwa

    2016-01-01

    Full Text Available Foamed concrete is a controlled low density ranging from 400kg/m3 to 1800kg/m3, and hence suitable for the construction of buildings and infrastructures. The uniqueness of foamed concrete is does not use aggregates in order to retain low density. Foamed concrete contains only cement, sand, water and foam agent. Therefore, the consumption of cement is higher in producing a good quality and strength of foamed concrete. Without the present of aggregates, the compressive strength of foamed concrete can only achieve as high as 15MPa. Therefore, this study aims to introduce the pelletized coconut fibre aggregate to reduce the consumption of cement but able to enhance the compressive strength. In the experimental study, forty-five (45 cube samples of foamed concrete with density 1600kg/m3 were prepared with different volume fractions of pelletized coconut fibre aggregate. All cube samples were tested using the compression test to obtain compressive strength. The results showed that the compressive strength of foamed concrete containing 5%, 10%, 15% and 20% of pelletized coconut fibre aggregate are 9.6MPa, 11.4MPa, 14.6MPa and 13.4MPa respectively. It is in fact higher than the controlled foamed concrete that only achieves 9MPa. It is found that the pelletized coconut fibre aggregate indicates a good potential to enhance the compressive strength of foamed concrete.

  11. Lipid nanoparticles for topical and transdermal application for alopecia treatment: development, physicochemical characterization, and in vitro release and penetration studies

    Directory of Open Access Journals (Sweden)

    Gomes MJ

    2014-03-01

    Full Text Available Maria João Gomes,1 Susana Martins,2,3 Domingos Ferreira,2 Marcela A Segundo,1 Salette Reis1 1REQUIMTE, Laboratory of Applied Chemistry, Department of Chemical Sciences, Faculty of Pharmacy, 2Laboratory of Pharmaceutical Technology, Department of Drug Sciences, Faculty of Pharmacy, University of Porto, Porto, Portugal; 3Department of Physics, Chemistry and Pharmacy, University of Southern Denmark, Odense, Denmark Abstract: Alopecia is a dermatological disorder, commonly known as hair loss, which affects up to half of the Caucasian male population by middle age, and almost all (95% Caucasian men by old age. Considering that alopecia affects so many people and that there is currently no scientifically proven treatment with few side effects, new drug-delivery systems able to improve alopecia therapy are urgently required. With this purpose in mind, the present study aimed to develop lipid nanoparticles (nanostructured lipid carriers with the ability to incorporate and deliver anti-alopecia active compounds (minoxidil and finasteride into the dermis and hair follicles. Lipid nanoparticles, prepared by ultrasonication method, showed mean particle sizes around 200 nm, which is sufficient for reaching the dermis and hair follicles, and zeta potential values around -30 mV, which indicates good physical stability. Over 28 days of storage, no significant variations in these parameters were observed, which indicates that all nanoformulations are stable in storage over that period. Cryo-scanning electron microscope measurements showed that all the lipid nanoparticles exhibited a spherical shape and a smooth surface regardless of their composition. Differential scanning calorimetry studies allowed the determination of phase transition temperatures and confirmed the recrystallization of the lipid nanoparticles (recrystallization index between 11% and 86%. A high loading efficiency was achieved for finasteride (between 70% and 90%, while less than 30% was

  12. The use of consumer depth cameras for 3D surface imaging of people with obesity: A feasibility study.

    Science.gov (United States)

    Wheat, J S; Clarkson, S; Flint, S W; Simpson, C; Broom, D R

    2018-05-21

    Three dimensional (3D) surface imaging is a viable alternative to traditional body morphology measures, but the feasibility of using this technique with people with obesity has not been fully established. Therefore, the aim of this study was to investigate the validity, repeatability and acceptability of a consumer depth camera 3D surface imaging system in imaging people with obesity. The concurrent validity of the depth camera based system was investigated by comparing measures of mid-trunk volume to a gold-standard. The repeatability and acceptability of the depth camera system was assessed in people with obesity at a clinic. There was evidence of a fixed systematic difference between the depth camera system and the gold standard but excellent correlation between volume estimates (r 2 =0.997), with little evidence of proportional bias. The depth camera system was highly repeatable - low typical error (0.192L), high intraclass correlation coefficient (>0.999) and low technical error of measurement (0.64%). Depth camera based 3D surface imaging was also acceptable to people with obesity. It is feasible (valid, repeatable and acceptable) to use a low cost, flexible 3D surface imaging system to monitor the body size and shape of people with obesity in a clinical setting. Copyright © 2018 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  13. PENETRATION OF CONICAL INDENTER INTO FOUNDATION MATERIAL AT COMBINED PERCUSSION AND SUBSEQUENT ULTRASONIC IMPACTS

    Directory of Open Access Journals (Sweden)

    M. G. Kiselev

    2012-01-01

    Full Text Available The aim of this paper is theoretical and experimental studys of a percussion and subsequent ultrasonic impacts on the indenter depth penetration into material of rigid-plastic foundation.The obtained results allow us to estimate an influence of percussion (low-frequency and ultrasound (high-frequency component parameters on a charging process.

  14. Partial-depth modulation study of anions and neutrals in low pressure silane plasmas

    International Nuclear Information System (INIS)

    Cozurteille, C.; Dorier, J.L.; Hollenstein, C.; Sansonnens; Howling, A.A.

    1995-10-01

    Partial-depth modulation of the rf power in a capacitive discharge is used to investigate the relative importance of negative ions and neutral radicals for particle formation in low power, low pressure silane plasmas. For less than 85% modulation depth, anions are trapped indefinitely in the plasma and particle formation ensues, whereas the polymerised neutral flux magnitudes and dynamics are independent of the modulation depth and the powder formation. These observations suggest that negative ions could be the particle precursors in plasma conditions where powder appears many seconds after plasma ignition. Microwave interferometry and mass spectrometry were combined to infer an anion density of ≅7.10 9 cm -3 which is approximately twice the free electron density in these modulated plasmas. (author) 6 figs., tabs., refs

  15. A prospective observational study of skin to subarachnoid space depth in the Indian population

    Directory of Open Access Journals (Sweden)

    Smita Prakash

    2014-01-01

    Full Text Available Background and Aims: A pre-puncture estimate of skin to subarachnoid space depth (SSD may guide spinal needle placement and reduce complications associated with lumbar puncture. Our aim was to determine (1 The SSD in Indian males, females, parturients and the overall population; (2 To derive formulae for predicting SSD and (3 To determine which previously suggested formula best suited our population. Methods: In this prospective, observational study, 800 adult Indian patients undergoing surgery under spinal anaesthesia were divided into three groups: Males (Group M, females (Group F and parturients (Group PF. SSD was measured after lumbar puncture. The relationship between SSD and patient characteristics was studied and statistical models were used to derive formula for predicting SSD. Statistical analysis included One-way ANOVA with post hoc analysis, forward stepwise multivariate regression analysis and paired t-tests. Results: Mean SSD was 4.71 ± 0.70 cm in the overall population. SSD in adult males (4.81 ± 0.68 cm was significantly longer than that observed in females (4.55 ± 0.66 cm but was comparable with SSD in parturients (4.73 ± 0.73 cm. Formula for predicting SSD in the overall population was 2.71 + 0.09 × Body Mass Index (BMI. Stocker′s formula when applied correlated best with the observed SSD. Formulae were derived for the three groups. Conclusions: We found gender-based differences in SSD, with SSD in males being significantly greater than that observed in the female population. SSD correlated with BMI in the parturient and the overall population. Amongst the previously proposed formulae, Stocker′s formula was most accurate in predicting SSD in our population.

  16. Women's experiences of using vaginal trainers (dilators) to treat vaginal penetration difficulties diagnosed as vaginismus: a qualitative interview study.

    Science.gov (United States)

    Macey, Kat; Gregory, Angela; Nunns, David; das Nair, Roshan

    2015-06-20

    Recent research has highlighted controversies in the conceptualisation, diagnosis and treatment of vaginismus. Vaginal trainers are currently the most widely used treatment. Critiques have highlighted concerns that the evidence-base of its effectiveness is limited, with controlled trials reporting disappointing results, and its prescription promotes 'performance-based' sexuality which may be detrimental. Despite this, little has been done to seek women's views about their treatment. This study set out to explore women's experiences of vaginismus treatment with vaginal trainers, and to use their voices to propose guidelines for improving treatment. 13 women who had used vaginal trainers for vaginal penetration difficulties diagnosed as vaginismus were recruited through a specialist clinic, university campuses, and online forums. The women took part in semi-structured individual interviews (face-to-face/telephone/Skype), which were audio-recorded, transcribed verbatim and analysed using Thematic Analysis. Four superordinate themes were elicited and used to draft 'better treatment' guidelines. Themes were: (1) Lack of knowledge, (2) Invalidation of suffering by professionals, (3) Difficult journey, and (4) Making the journey easier. This paper describes themes (3) and (4). Difficult Journey describes the long and arduous 'Journey into treatment', including difficulties asking for help, undergoing physical investigations and negotiating 'the system' of medical referrals. It also describes the sometimes demoralising process of 'being in treatment', which includes emotional and practical demands of treatment. Making the journey easier highlights the importance of and limits to 'partner support'. 'Professional support' comprises personal qualities of professionals/therapeutic relationship, the value of specialist skills and knowledge and the need for facilitating couple communication about vaginismus. 'Peer support/helping each other' describes the importance of

  17. Quantitative EEG in assessment of anaesthetic depth: comparative study of methodology

    DEFF Research Database (Denmark)

    Thomsen, C. E.; Prior, P. F.

    1996-01-01

    ) and (4) a depth of anaesthesia monitor based on EEG pattern recognition (ADAM). Dose-response curves are presented for stepwise increases in stable end-tidal concentrations of each agent. Results indicated considerable inter-patient variability and the limitations of single EEG measures, particularly......Methodology for assessment of depth of anaesthesia based on analysis of the electroencephalogram (EEG) is controversial. Techniques range from display of single measures, for example median value of the frequency spectrum, to dedicated pattern recognition systems based on measures of several EEG...

  18. Study the Effect of Intermittent and Continuous Ponding Depths by Using Different Heads to Leach Water

    Directory of Open Access Journals (Sweden)

    Nesrin J. AL-Mansori

    2018-03-01

    Full Text Available As results of using water for irrigated lands in a random manner in a time of shortage main water resources, Experimental work carried out to study the effect of continuous and intermittent ponding depth on the leaching processes. Sandy soil used, sourced from Hilla / Al-Jameeya, at Hilla city. Sieve analysis and hydrometer testing used to identify the properties of the soil. A model used with dimensions of 30, 30 and, 70 cm, with two different heads of water. Shatt-Al-Hilla River samples used in the leaching process.   Chemical tests carried out before the leaching process to identify changes in the proprieties in both water and soil. Leachate collected from two soil columns drained into boxes and tests carried out every 30 minutes. After the leaching process was complete, the soil was re-tested. Chemical tests on soil samples and the collected water applied after leaching for 47.5 cm and 52.5cm heads. From the results،, it can be notice that electrical conductivity for the outlet discharge from soil samples decreased faster with time, then slowing down until the end of leaching process.  The same pattern can be seen for all soil properties. In continuous leaching, a large quantity of water is required over a short leaching period, the inverse true for intermittent leaching. All parameters reduce with time in continuous leaching in comparison to intermittent leaching but when the water level in the soil column compared, it can inferred that increasing the head will reduce all the parameters for soil.

  19. Depth of anaesthesia monitoring in obese patients: a randomized study of propofol-remifentanil

    DEFF Research Database (Denmark)

    Meyhoff, C S; Henneberg, S W; Jørgensen, B G

    2009-01-01

    BACKGROUND: In obese patients, depth of anaesthesia monitoring could be useful in titrating intravenous anaesthetics. We hypothesized that depth of anaesthesia monitoring would reduce recovery time and use of anaesthetics in obese patients receiving propofol and remifentanil. METHODS: We investig......BACKGROUND: In obese patients, depth of anaesthesia monitoring could be useful in titrating intravenous anaesthetics. We hypothesized that depth of anaesthesia monitoring would reduce recovery time and use of anaesthetics in obese patients receiving propofol and remifentanil. METHODS: We...... investigated 38 patients with a body mass index >or=30 kg/m(2) scheduled for an abdominal hysterectomy. Patients were randomized to either titration of propofol and remifentanil according to a cerebral state monitor (CSM group) or according to usual clinical criteria (control group). The primary end point.......04). During surgery, when the cerebral state index was continuously between 40 and 60, the corresponding optimal propofol infusion rate was 10 mg/kg/h based on ideal body weight. CONCLUSION: No significant reduction in time to eye opening could be demonstrated when a CSM was used to titrate propofol...

  20. Solid-state NMR paramagnetic relaxation enhancement immersion depth studies in phospholipid bilayers

    KAUST Repository

    Chu, Shidong; Maltsev, Sergey B.; Emwas, Abdul-Hamid M.; Lorigan, Gary A.

    2010-01-01

    A new approach for determining the membrane immersion depth of a spin-labeled probe has been developed using paramagnetic relaxation enhancement (PRE) in solid-state NMR spectroscopy. A DOXYL spin label was placed at different sites of 1-palmitoyl-2

  1. A Simulation-based Randomized Controlled Study of Factors Influencing Chest Compression Depth

    Directory of Open Access Journals (Sweden)

    Kelsey P. Mayrand

    2015-12-01

    Full Text Available Introduction: Current resuscitation guidelines emphasize a systems approach with a strong emphasis on quality cardiopulmonary resuscitation (CPR. Despite the American Heart Association (AHA emphasis on quality CPR for over 10 years, resuscitation teams do not consistently meet recommended CPR standards. The objective is to assess the impact on chest compression depth of factors including bed height, step stool utilization, position of the rescuer’s arms and shoulders relative to the point of chest compression, and rescuer characteristics including height, weight, and gender. Methods: Fifty-six eligible subjects, including physician assistant students and first-year emergency medicine residents, were enrolled and randomized to intervention (bed lowered and step stool readily available and control (bed raised and step stool accessible, but concealed groups. We instructed all subjects to complete all interventions on a high-fidelity mannequin per AHA guidelines. Secondary end points included subject arm angle, height, weight group, and gender. Results: Using an intention to treat analysis, the mean compression depths for the intervention and control groups were not significantly different. Subjects positioning their arms at a 90-degree angle relative to the sagittal plane of the mannequin’s chest achieved a mean compression depth significantly greater than those compressing at an angle less than 90 degrees. There was a significant correlation between using a step stool and achieving the correct shoulder position. Subject height, weight group, and gender were all independently associated with compression depth. Conclusion: Rescuer arm position relative to the patient’s chest and step stool utilization during CPR are modifiable factors facilitating improved chest compression depth.

  2. Adding Endoscopist-Directed Flexible Endoscopic Evaluation of Swallowing to the Videofluoroscopic Swallowing Study Increased the Detection Rates of Penetration, Aspiration, and Pharyngeal Residue.

    Science.gov (United States)

    Park, Won Young; Lee, Tae Hee; Ham, Nam Seok; Park, Ji Woong; Lee, Yang Gyun; Cho, Sang Jin; Lee, Joon Seong; Hong, Su Jin; Jeon, Seong Ran; Kim, Hyun Gun; Cho, Joo Young; Kim, Jin Oh; Cho, Jun Hyung; Lee, Ji Sung

    2015-09-23

    Currently, the videofluoroscopic swallowing study (VFSS) is the standard tool for evaluating dysphagia. We evaluated whether the addition of endoscopist-directed flexible endoscopic evaluation of swallowing (FEES) to VFSS could improve the detection rates of penetration, aspiration, and pharyngeal residue, compared the diagnostic efficacy between VFSS and endoscopist-directed FEES and assessed the adverse events of the FEES. In single tertiary referral center, a retrospective analysis of prospectively collected data was conducted. Fifty consecutive patients suspected of oropharyngeal dysphagia were enrolled in this study between January 2012 and July 2012. The agreement in the detection of penetration and aspiration between VFSS and FEES of viscous food (κ=0.34; 95% confidence interval [CI], 0.15 to 0.53) and liquid food (κ=0.22; 95% CI, 0.02 to 0.42) was "fair." The agreement in the detection of pharyngeal residue between the two tests was "substantial" with viscous food (κ=0.63; 95% CI, 0.41 to 0.94) and "fair" with liquid food (κ=0.37; 95% CI, 0.10 to 0.63). Adding FEES to VFSS significantly increased the detection rates of penetration, aspiration, and pharyngeal residue. No severe adverse events were noted during FEES, except for two cases of epistaxis, which stopped spontaneously without requiring any packing. This study demonstrated that the addition of endoscopist-directed FEES to VFSS increased the detection rates of penetration, aspiration, and pharyngeal residue.

  3. Interactions of calcium ions with weakly acidic active ingredients slow cuticular penetration: a case study with glyphosate.

    Science.gov (United States)

    Schönherr, Jörg; Schreiber, Lukas

    2004-10-20

    Potassium and calcium salts of glyphosate were obtained by titrating glyphosate acid with the respective bases to pH 4.0, and rates of penetration of these salts across isolated astomatous cuticular membranes (CMs) were measured at 20 degrees C and 70, 80, 90, and 100% humidity. K-glyphosate exhibited first-order penetration kinetics, and rate constants (k) increased with increasing humidity. Ca-glyphosate penetrated only when the humidity above the salt residue was 100%. At 90% humidity and below, Ca-glyphosate formed a solid residue on the CMs and penetration was not measurable. With Ca-glyphosate, the k value at 100% humidity decreased with time and the initial rates were lower than for K-glyphosate by a factor of 3.68. After equimolar concentrations of ammonium oxalate were added to Ca-glyphosate, high penetration rates close to those measured with K-glyphosate were measured at all humidities. Adding ammonium sulfate or potassium carbonate also increased rates between 70 and 100% humidity, but they were not as high as with ammonium oxalate. The data indicate that at pH 4.0 one Ca2+ ion is bound to two glyphosate anions. This salt has its deliquescence point near 100% humidity. Therefore, it is a solid at lower humidity and does not penetrate. Its molecular weight is 1.82 times larger than that of K-glyphosate, and this greatly slows down rates of penetration, even at 100% humidity. The additives tested have low solubility products and form insoluble precipitates with Ca2+ ions, but only ammonium oxalate binds Ca2+ quantitatively. The resulting ammonium salt of glyphosate penetrates at 70-100% humidity and at rates comparable to K-glyphosate. The results contribute to a better understanding of the hard water antagonism observed with glyphosate. It is argued that other pesticides and hormones with carboxyl functions are likely to respond to Ca2+ ions in a similar fashion. In all of these cases, ammonium oxalate is expected to overcome hard water antagonism

  4. Consistent constitutive modeling of metallic target penetration using empirical, analytical, and numerical penetration models

    Directory of Open Access Journals (Sweden)

    John (Jack P. Riegel III

    2016-04-01

    Full Text Available Historically, there has been little correlation between the material properties used in (1 empirical formulae, (2 analytical formulations, and (3 numerical models. The various regressions and models may each provide excellent agreement for the depth of penetration into semi-infinite targets. But the input parameters for the empirically based procedures may have little in common with either the analytical model or the numerical model. This paper builds on previous work by Riegel and Anderson (2014 to show how the Effective Flow Stress (EFS strength model, based on empirical data, can be used as the average flow stress in the analytical Walker–Anderson Penetration model (WAPEN (Anderson and Walker, 1991 and how the same value may be utilized as an effective von Mises yield strength in numerical hydrocode simulations to predict the depth of penetration for eroding projectiles at impact velocities in the mechanical response regime of the materials. The method has the benefit of allowing the three techniques (empirical, analytical, and numerical to work in tandem. The empirical method can be used for many shot line calculations, but more advanced analytical or numerical models can be employed when necessary to address specific geometries such as edge effects or layering that are not treated by the simpler methods. Developing complete constitutive relationships for a material can be costly. If the only concern is depth of penetration, such a level of detail may not be required. The effective flow stress can be determined from a small set of depth of penetration experiments in many cases, especially for long penetrators such as the L/D = 10 ones considered here, making it a very practical approach. In the process of performing this effort, the authors considered numerical simulations by other researchers based on the same set of experimental data that the authors used for their empirical and analytical assessment. The goals were to establish a

  5. Penetration of fast projectiles into resistant media: From macroscopic to subatomic projectiles

    Science.gov (United States)

    Gaite, José

    2017-09-01

    The penetration of a fast projectile into a resistant medium is a complex process that is suitable for simple modeling, in which basic physical principles can be profitably employed. This study connects two different domains: the fast motion of macroscopic bodies in resistant media and the interaction of charged subatomic particles with matter at high energies, which furnish the two limit cases of the problem of penetrating projectiles of different sizes. These limit cases actually have overlapping applications; for example, in space physics and technology. The intermediate or mesoscopic domain finds application in atom cluster implantation technology. Here it is shown that the penetration of fast nano-projectiles is ruled by a slightly modified Newton's inertial quadratic force, namely, F ∼v 2 - β, where β vanishes as the inverse of projectile diameter. Factors essential to penetration depth are ratio of projectile to medium density and projectile shape.

  6. Avaliação da microinfiltração marginal e profundidade de penetração dos cimentos de ionômero de vidro utilizados como selantes oclusais Evaluation of marginal microleakage and depth of penetration of glass ionomer cements used as occlusal sealants

    Directory of Open Access Journals (Sweden)

    Marina de Lourdes Calvo Fracasso

    2005-09-01

    Full Text Available OBJETIVE: the aim of this study was to conduct an in vitro comparison of marginal microleakage (MM and the depth of penetration (DP of glass ionomer cements (GIC and a resin sealant (RS into occlusal pit and fissures. METHODS: for that purpose, 60 intact third molars were equally distributed to 5 groups: G1 - 37% phosphoric acid / Delton; G2 - 40% polyacrylic acid / Ketac-Molar / nail varnish; G3 - Fuji Plus conditioner / Fuji Plus/ nail varnish; G4 -37% phosphoric acid / Vitremer / Finishing gloss; G5 -37% phosphoric acid / Vitremer prepared with a 1:4 ratio of powder / Finishing gloss. The teeth were submitted to a thermal treatment corresponding to 300 cycles (15 sec, 5/55(0C, followed by complete coating with nail varnish, except for 1mm beyond the contour of the sealant. Afterwards, the teeth were immersed in 0.5% basic fuchsine for 24 hours. Thereafter, the teeth were sectioned in buccolingual direction and microscopically analyzed (150x magnification by means of predetermined scores. The results were subject to the Kruskal-Wallis test. RESULTS: there was no statistical difference between the materials tested in relation to the DP, being that all groups displayed nearly complete filling of the fissures. No sealant material was able to prevent dye penetration; however, the GICs provided better results of MM, with significant difference when compared to the RS. CONCLUSION: all materials investigated presented a satisfactory degree of penetration into the fissures; however, the glass ionomer cements displayed better performance in the marginal microleakage test compared to the resin sealant.OBJETIVO: o objetivo deste estudo foi comparar in vitro a microinfiltração marginal (MM e o grau de profundidade de penetração (DP de cimentos de ionômero de vidro (CIV e um selante resinoso (SR em fossas e fissuras oclusais. MATERIAIS E MÉTODOS: para tanto, 60 terceiros molares hígidos foram igualmente distribuídos em 5 grupos: G1- ácido fosf

  7. Dependence of residual displacements on the width and depth of compliant fault zones: a 3D study

    Science.gov (United States)

    Kang, J.; Duan, B.

    2011-12-01

    Compliant fault zones have been detected along active faults by seismic investigations (trapped waves and travel time analysis) and InSAR observations. However, the width and depth extent of compliant fault zones are still under debate in the community. Numerical models of dynamic rupture build a bridge between theories and the geological and geophysical observations. Theoretical 2D plane-strain studies of elastic and inelastic response of compliant fault zones to nearby earthquake have been conducted by Duan [2010] and Duan et al [2010]. In this study, we further extend the experiments to 3D with a focus on elastic response. We are specifically interested in how residual displacements depend on the structure and properties of complaint fault zones, in particular on the width and depth extent. We conduct numerical experiments on various types of fault-zone models, including fault zones with a constant width along depth, with decreasing widths along depth, and with Hanning taper profiles of velocity reduction. . Our preliminary results suggest 1) the width of anomalous horizontal residual displacement is only indicative of the width of a fault zone near the surface, and 2) the vertical residual displacement contains information of the depth extent of compliant fault zones.

  8. "Disruptive Technologies", "Pedagogical Innovation": What's New? Findings from an In-Depth Study of Students' Use and Perception of Technology

    Science.gov (United States)

    Conole, Grainne; de Laat, Maarten; Dillon, Teresa; Darby, Jonathan

    2008-01-01

    The paper describes the findings from a study of students' use and experience of technologies. A series of in-depth case studies were carried out across four subject disciplines, with data collected via survey, audio logs and interviews. The findings suggest that students are immersed in a rich, technology-enhanced learning environment and that…

  9. Ground-penetrating radar (GPR) responses for sub-surface salt contamination and solid waste: modeling and controlled lysimeter studies.

    Science.gov (United States)

    Wijewardana, Y N S; Shilpadi, A T; Mowjood, M I M; Kawamoto, K; Galagedara, L W

    2017-02-01

    The assessment of polluted areas and municipal solid waste (MSW) sites using non-destructive geophysical methods is timely and much needed in the field of environmental monitoring and management. The objectives of this study are (i) to evaluate the ground-penetrating radar (GPR) wave responses as a result of different electrical conductivity (EC) in groundwater and (ii) to conduct MSW stratification using a controlled lysimeter and modeling approach. A GPR wave simulation was carried out using GprMax2D software, and the field test was done on two lysimeters that were filled with sand (Lysimeter-1) and MSW (Lysimeter-2). A Pulse EKKO-Pro GPR system with 200- and 500-MHz center frequency antennae was used to collect GPR field data. Amplitudes of GPR-reflected waves (sub-surface reflectors and water table) were studied under different EC levels injected to the water table. Modeling results revealed that the signal strength of the reflected wave decreases with increasing EC levels and the disappearance of the subsurface reflection and wave amplitude reaching zero at higher EC levels (when EC >0.28 S/m). Further, when the EC level was high, the plume thickness did not have a significant effect on the amplitude of the reflected wave. However, it was also found that reflected signal strength decreases with increasing plume thickness at a given EC level. 2D GPR profile images under wet conditions showed stratification of the waste layers and relative thickness, but it was difficult to resolve the waste layers under dry conditions. These results show that the GPR as a non-destructive method with a relatively larger sample volume can be used to identify highly polluted areas with inorganic contaminants in groundwater and waste stratification. The current methods of MSW dumpsite investigation are tedious, destructive, time consuming, costly, and provide only point-scale measurements. However, further research is needed to verify the results under heterogeneous aquifer

  10. Depth of origin of sputtered atoms: Experimental and theoretical study of Cu/Ru(0001)

    International Nuclear Information System (INIS)

    Burnett, J.W.; Biersack, J.P.; Gruen, D.M.; Joergensen, B.; Krauss, A.R.; Pellin, M.J.; Schweitzer, E.L.; Yates, J.T. Jr.; Young, C.E.

    1987-01-01

    The depth of origin of sputtered atoms is a subject of considerable interest. The surface sensitivity of analytical techniques such as Secondary Ion Mass Spectrometry (SIMS) and Surface Analysis by Resonance Ionization of Sputtered Atoms (SARISA), and the sputtering properties of strongly segregating alloy systems, are critically dependent on the sputtering depth of origin. A significant discrepancy exists between the predictions of the Sigmund theory and computer sputtering models; in general, the computer models predict a much shallower depth of origin. The existing experimental evidence suggests that most of the sputtered atoms originate in the topmost atomic layer, but until recently, the results have not been definitive. We have experimentally determined the depth of origin of atoms sputtered from surfaces consisting of Cu films of less than two monolayers on a Ru(0001) substrate. The Cu/Ru target was statically sputtered using 3.6 keV Ar + . The sputtered neutrals were non-resonantly laser ionized and detected using SARISA. The Cu/Ru sputtering yield ratio and the suppression of the Ru sputtering yield were determined for various Cu coverages. The results indicate that the majority of the sputtered atoms originate in the topmost atomic layer. The Cu/Ru system is also modeled using a modified Transport of Ions in Matter (TRIM) code. It was found that TRIM C does not correctly treat the first atomic layer, resulting in a serious underestimate of the number of sputtered atoms which originate in this layer. The corrected version adequately describes the results, predicting that for the experimental conditions roughly two-thirds of the sputtered atoms originate in the first atomic layer. These results are significantly greater than the Sigmund theory estimate of >40%. 26 refs., 3 figs., 1 tab

  11. Solid-state NMR paramagnetic relaxation enhancement immersion depth studies in phospholipid bilayers

    KAUST Repository

    Chu, Shidong

    2010-11-01

    A new approach for determining the membrane immersion depth of a spin-labeled probe has been developed using paramagnetic relaxation enhancement (PRE) in solid-state NMR spectroscopy. A DOXYL spin label was placed at different sites of 1-palmitoyl-2-stearoyl-sn-glycero-3-phosphocholine (PSPC) phospholipid bilayers as paramagnetic moieties and the resulting enhancements of the longitudinal relaxation (T1) times of 31P nuclei on the surface of the bilayers were measured by a standard inversion recovery pulse sequence. The 31P NMR spin-lattice relaxation times decrease steadily as the DOXYL spin label moves closer to the surface as well as the concentration of the spin-labeled lipids increase. The enhanced relaxation vs. the position and concentration of spin-labels indicate that PRE induced by the DOXYL spin label are significant to determine longer distances over the whole range of the membrane depths. When these data were combined with estimated correlation times τc, the r-6-weighted, time-averaged distances between the spin-labels and the 31P nuclei on the membrane surface were estimated. The application of using this solid-state NMR PRE approach coupled with site-directed spin labeling (SDSL) may be a powerful method for measuring membrane protein immersion depth. © 2010 Elsevier Inc. All rights reserved.

  12. Is Grey Level a Suitable Alternative to Low-Contrast Penetration as a Serial Measure of Sensitivity in Computerised Ultrasound Quality Assurance?

    Science.gov (United States)

    Dudley, Nicholas J; Gibson, Nicholas M

    2017-02-01

    The aim of this study was to test the hypothesis that grey levels are a suitable alternative measure of sensitivity in ultrasound imaging quality assurance, as there are several caveats in the use of penetration depth. In a primary cohort of nine probes, where measurements had been made for 6 to 34 mo, both penetration depth and mean grey level fell below tolerance for six probes; both penetration depth and mean grey level remained within tolerance for three probes. In a secondary cohort where a measurement programme had been in place for a shorter period, grey level and/or penetration depth fell below tolerance in 15 of 66 probes; the sensitivity and specificity of at least 10% loss of grey level in predicting >5% loss in penetration depth were 91% and 93%, respectively. A loss of grey level accompanies a loss of penetration and provides a suitable alternative measure of sensitivity. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  13. Preclinical pilot study monitoring topical drug penetration and dermal bioavailability of a peptidase inhibitor from different galenic formulations into pig dermis, using cutaneous microdialysis.

    Science.gov (United States)

    Quist, S R; Heimburg, A; Bank, U; Mahnkopf, D; Koch, G; Gollnick, H; Täger, M; Ansorge, S

    2017-08-01

    Cutaneous microdialysis (CM) is an ex vivo technique that allows study of tissue chemistry, including bioavailability of actual tissue concentration of unbound drug in the interstitial fluid of the body. To test the penetration and dermal bioavailability of galenic formulations of the small-molecule IP10.C8, a dual-protease inhibitor of the dipeptidyl peptidase and aminopeptidase families. Using CM, we tested the penetration and dermal bioavailability of IP10.C8 into the dermis and subcutis of pigs, and determined the tissue concentration of IP10.C8 enzymatically, using an enzyme activity assay (substrate Gly-Pro-pNA) and high performance liquid chromatography. Dermal bioavailability was enhanced by using microemulsion or the addition of the penetration enhancer oleic acid to a hydroxyethylcellulose (HEC) gel formulation. Dermal bioavailability was also enhanced when galenic formulations were prepared with higher pH (7.5 vs. 6.5) or higher drug concentration (5% vs. 1%) in HEC gel. It seems possible, using CM for topical skin penetration testing in anaesthetized domestic pigs, to test the bioavailability of newly designed drugs. However, the experimental time is limited due to the anaesthesia, and is dependent on drug recovery. Validation of this technique for routine use is challenging, and more experiments are needed to validate this preclinical set-up. © 2017 British Association of Dermatologists.

  14. Pars Plana-Modified versus Conventional Ahmed Glaucoma Valve in Patients Undergoing Penetrating Keratoplasty: A Prospective Comparative Randomized Study.

    Science.gov (United States)

    Parihar, Jitendra Kumar Singh; Jain, Vaibhav Kumar; Kaushik, Jaya; Mishra, Avinash

    2017-03-01

    To compare the outcome of pars-plana-modified Ahmed glaucoma valve (AGV) versus limbal-based conventional AGV into the anterior chamber, in patients undergoing penetrating keratoplasty (PK) for glaucoma with coexisting corneal diseases. In this prospective randomized clinical trial, 58 eyes of 58 patients with glaucoma and coexisting corneal disease were divided into two groups. Group 1 (29 eyes of 29 patients) included patients undergoing limbal-based conventional AGV into the anterior chamber (AC) along-with PK and group 2 (29 eyes of 29 patients) included those undergoing pars-plana-modified AGV along-with PK. Outcome measures included corneal graft clarity, intraocular pressure (IOP), number of antiglaucoma medications, and postoperative complications. Patients were followed up for a minimum period of 2 years. Out of 58 eyes (58 patients), 50 eyes (50 patients: 25 eyes of 25 patients each in group 1 and group 2) completed the study and were analyzed. Complete success rate for AGV (group 1: 76%; group 2: 72%; p = 0.842) and corneal graft clarity (group 1: 68%; group 2: 76%; p = 0.081) were comparable between the two groups at 2 years. Graft failure was more in conventional AGV (32%) as compared to pars plana-modified AGV (24%) but not statistically significant (p = 0.078) at 2 years. Though both procedures were comparable in various outcome measures, pars-plana-modified AGV is a viable option for patients undergoing PK, as it provides a relatively better corneal graft survival rate and lesser complications that were associated with conventional AGV.

  15. The Basics of Hacking and Penetration Testing Ethical Hacking and Penetration Testing Made Easy

    CERN Document Server

    Engebretson, Patrick

    2011-01-01

    The Basics of Hacking and Penetration Testing serves as an introduction to the steps required to complete a penetration test or perform an ethical hack. You learn how to properly utilize and interpret the results of modern day hacking tools; which are required to complete a penetration test. Tool coverage will include, Backtrack Linux, Google, Whois, Nmap, Nessus, Metasploit, Netcat, Netbus, and more. A simple and clean explanation of how to utilize these tools will allow you  to gain a solid understanding of each of the four phases and prepare them to take on more in-depth texts and topi

  16. A Comparative Revolution? An Argument for In-Depth Study of the Iranian Revolution in a Familiar Way

    Science.gov (United States)

    White, Jonathan

    2011-01-01

    Although the curriculum changes of 2008 brought with them new GCSE specifications, Jonathan White was disappointed by the dated feel of some "Modern World" options, particularly the depth studies on offer. Drawing on his experience of teaching comparative history within the International Baccalaureate, and building on previous arguments…

  17. Individual Differences in Students' Knowing and Learning about Fractions: Evidence from an In-Depth Qualitative Study

    Science.gov (United States)

    Bempeni, Maria; Vamvakoussi, Xenia

    2015-01-01

    We present the results of an in-depth qualitative study that examined ninth graders' conceptual and procedural knowledge of fractions as well as their approach to mathematics learning, in particular fraction learning. We traced individual differences, even extreme, in the way that students combine the two kinds of knowledge. We also provide…

  18. Clashing Validities in the Comparative Method? Balancing In-Depth Understanding and Generalizability in Small-N Policy Studies

    NARCIS (Netherlands)

    van der Heijden, J.

    2013-01-01

    The comparative method receives considerable attention in political science. To some a main advantage of the method is that it allows for both in-depth insights (internal validity), and generalizability beyond the cases studied (external validity). However, others consider internal and external

  19. The Brooklyn traffic real-time ambient pollutant penetration and environmental dispersion (B-TRAPPED) field study methodology.

    Science.gov (United States)

    Richmond-Bryant, Jennifer; Hahn, Intaek; Fortune, Christopher R; Rodes, Charles E; Portzer, Jeffrey W; Lee, Sangdon; Wiener, Russell W; Smith, Luther A; Wheeler, Michael; Seagraves, Jeremy; Stein, Mark; Eisner, Alfred D; Brixey, Laurie A; Drake-Richman, Zora E; Brouwer, Lydia H; Ellenson, William D; Baldauf, Richard

    2009-12-01

    The Brooklyn Traffic Real-Time Ambient Pollutant Penetration and Environmental Dispersion (B-TRAPPED) field study examined indoor and outdoor exposure to traffic-generated air pollution by studying the individual processes of generation of traffic emissions, transport and dispersion of air contaminants along a roadway, and infiltration of the contaminants into a residence. Real-time instrumentation was used to obtain highly resolved time-series concentration profiles for a number of air pollutants. The B-TRAPPED field study was conducted in the residential Sunset Park neighborhood of Brooklyn, NY, USA, in May 2005. The neighborhood contained the Gowanus Expressway (Interstate 278), a major arterial road (4(th) Avenue), and residential side streets running perpendicular to the Gowanus Expressway and 4(th) Avenue. Synchronized measurements were obtained inside a test house, just outside the test house façade, and along the urban residential street canyon on which the house was located. A trailer containing Federal Reference Method (FRM) and real-time monitors was located next to the Gowanus Expressway to assess the source. Ultrafine particulate matter (PM), PM(2.5), nitrogen oxides (NO(x)), sulfur dioxide (SO(2)), carbon monoxide (CO), carbon dioxide (CO(2)), temperature, relative humidity, and wind speed and direction were monitored. Different sampling schemes were devised to focus on dispersion along the street canyon or infiltration into the test house. Results were obtained for ultrafine PM, PM(2.5), criteria gases, and wind conditions from sampling schemes focused on street canyon dispersion and infiltration. For comparison, the ultrafine PM and PM(2.5) results were compared with an existing data set from the Los Angeles area, and the criteria gas data were compared with measurements from a Vancouver epidemiologic study. Measured ultrafine PM and PM(2.5) concentration levels along the residential urban street canyon and at the test house façade in Sunset Park

  20. Retrieval of Aerosol Optical Depth Above Clouds from OMI Observations: Sensitivity Analysis, Case Studies

    Science.gov (United States)

    Torres, O.; Jethva, H.; Bhartia, P. K.

    2012-01-01

    A large fraction of the atmospheric aerosol load reaching the free troposphere is frequently located above low clouds. Most commonly observed aerosols above clouds are carbonaceous particles generally associated with biomass burning and boreal forest fires, and mineral aerosols originated in arid and semi-arid regions and transported across large distances, often above clouds. Because these aerosols absorb solar radiation, their role in the radiative transfer balance of the earth atmosphere system is especially important. The generally negative (cooling) top of the atmosphere direct effect of absorbing aerosols, may turn into warming when the light-absorbing particles are located above clouds. The actual effect depends on the aerosol load and the single scattering albedo, and on the geometric cloud fraction. In spite of its potential significance, the role of aerosols above clouds is not adequately accounted for in the assessment of aerosol radiative forcing effects due to the lack of measurements. In this paper we discuss the basis of a simple technique that uses near-UV observations to simultaneously derive the optical depth of both the aerosol layer and the underlying cloud for overcast conditions. The two-parameter retrieval method described here makes use of the UV aerosol index and reflectance measurements at 388 nm. A detailed sensitivity analysis indicates that the measured radiances depend mainly on the aerosol absorption exponent and aerosol-cloud separation. The technique was applied to above-cloud aerosol events over the Southern Atlantic Ocean yielding realistic results as indicated by indirect evaluation methods. An error analysis indicates that for typical overcast cloudy conditions and aerosol loads, the aerosol optical depth can be retrieved with an accuracy of approximately 54% whereas the cloud optical depth can be derived within 17% of the true value.

  1. Depth of word processing in Alzheimer patients and normal controls: a magnetoencephalographic (MEG) study.

    Science.gov (United States)

    Walla, P; Püregger, E; Lehrner, J; Mayer, D; Deecke, L; Dal Bianco, P

    2005-05-01

    Effects related to depth of verbal information processing were investigated in probable Alzheimer's disease patients (AD) and age matched controls. During word encoding sessions 10 patients and 10 controls had either to decide whether the letter "s" appeared in visually presented words (alphabetical decision, shallow encoding), or whether the meaning of each presented word was animate or inanimate (lexical decision, deep encoding). These encoding sessions were followed by test sessions during which all previously encoded words were presented again together with the same number of new words. The task was then to discriminate between repeated and new words. Magnetic field changes related to brain activity were recorded with a whole cortex MEG.5 probable AD patients showed recognition performances above chance level related to both depths of information processing. Those patients and 5 age matched controls were then further analysed. Recognition performance was poorer in probable AD patients compared to controls for both levels of processing. However, in both groups deep encoding led to a higher recognition performance than shallow encoding. We therefore conclude that the performance reduction in the patient group was independent of depth of processing. Reaction times related to false alarms differed between patients and controls after deep encoding which perhaps could already be used for supporting an early diagnosis. The analysis of the physiological data revealed significant differences between correctly recognised repetitions and correctly classified new words (old/new-effect) in the control group which were missing in the patient group after deep encoding. The lack of such an effect in the patient group is interpreted as being due to the respective neuropathology related to probable AD. The present results demonstrate that magnetic field recordings represent a useful tool to physiologically distinguish between probable AD and age matched controls.

  2. A study of estimating cutting depth for multi-pass nanoscale cutting by using atomic force microscopy

    International Nuclear Information System (INIS)

    Lin, Zone-Ching; Hsu, Ying-Chih

    2012-01-01

    This paper studies two models for estimating cutting depth of multi-pass nanoscale cutting by using an atomic force microscopy (AFM) probe. One estimates cutting depth for multi-pass nanoscale cutting by using regression equations of nanoscale contact pressure factor (NCP factor) while the other uses equation of specific down force energy (SDFE). This paper proposes taking a diamond-coated probe of AFM as the cutting tool to carry out multi-pass nanoscale cutting experiments on the surface of sapphire substrate. In the process of experimentation, different down forces are set, and the probe shape of AFM is known, then using each down force to multi-pass cutting the sapphire substrate. From the measured experimental data of a central cutting depth of the machining groove by AFM, this paper calculates the specific down force energy of each down force. The experiment results reveal that the specific down force energy of each case of multi-pass nanoscale cutting for different down forces under a probe of AFM is close to a constant value. This paper also compares the nanoscale cutting results from estimating cutting depths for each pass of multi-pass among the experimental results and the calculating results obtained by the two theories models. It is found that the model of specific down force energy can calculate cutting depths for each nanoscale cutting pass by one equation. It is easier to use than the multi-regression equations of the nanoscale contact pressure factor. Besides, the estimations of cutting depth results obtained by the model of specific down force energy are closer to that of the experiment results. It shows that the proposed specific down force energy model in this paper is an acceptable model.

  3. Munition Penetration Depth Prediction: SERDP SEED Project MR 2629

    Science.gov (United States)

    2017-08-01

    25 10 Time trace of impact forces estimated from the DEM simulation of the projectile- drop test. The time evolution of...and a Coulomb friction cap on the tangential force. The force components depend on the overlap between dilated grains. The overlap δ between a pair of...2 subject to ∈ (1,2, 1) and 1,2 ∈ [−1,1] (22) where z is the norm square distance between a point y on the coupling sur

  4. Influence of soil parameters on depth of oil waste penetration

    Directory of Open Access Journals (Sweden)

    Rychlicki Stanislaw

    2004-09-01

    Full Text Available A measurement post for testing propagation of hydrocarbon contamination in a model of a near-surface soil layer and its remediation, are characterized in the paper. Generalized results of laboratory observations require meeting similarity criteria of the laboratory and actual processes. These requirements were used when designing the measurement post. A successful attempt to match a theoretical model describing oil products filtration necessitates certain conditions, e.g. homogeneity of the physical model of soil and characteristic of the course of the analyzed processes.

  5. Simulation of depth of penetration during ballistic impact on thick ...

    Indian Academy of Sciences (India)

    One-dimensional discrete element model for the ballistic impact is used ... Simulation of ballistic impact process has been done using several ..... MATLAB 7.0 platform is used to simulate impact process using 1-D DEM and to perform the.

  6. Determination of the depth of an etch pit through studies of diffraction rings

    Energy Technology Data Exchange (ETDEWEB)

    Basu, B. [Department of Physics, Bose Institute, 93/1 APC Road, Kolkata 700 009 (India); Centre for Astroparticle Physics and Space Science, Bose institute, Kolkata 700 091 (India); Dey, S.; Maulik, A. [Centre for Astroparticle Physics and Space Science, Bose institute, Kolkata 700 091 (India); Raha, Sibaji [Department of Physics, Bose Institute, 93/1 APC Road, Kolkata 700 009 (India); Centre for Astroparticle Physics and Space Science, Bose institute, Kolkata 700 091 (India); Saha, S. [Nuclear and Atomic Physics Division, Saha Institute of Nuclear Physics, Kolkata 700 064 (India); Saha, Swapan K. [Department of Physics, Bose Institute, 93/1 APC Road, Kolkata 700 009 (India); Centre for Astroparticle Physics and Space Science, Bose institute, Kolkata 700 091 (India)], E-mail: swapan@bosemain.boseinst.ac.in; Syam, D. [Department of Physics, Presidency College, Kolkata 700 073 (India)

    2009-04-15

    A Solid State Nuclear Track Detector (SSNTD) can be used to identify an impinging ion as well as to determine the energy of that ion. The track of the ion is made visible by chemically 'etching' the detector after exposure. By finding out the ratio of the track-etch rate (V{sub t}) to the bulk-etch rate (V{sub g}), together with the range of the ion in the detector, the identity and the energy of the ion can be ascertained. The required measurements can be conveniently made with the help of a microscope when the angle of incidence of the ion, with respect to the normal direction to the detector surface, is more than 15 deg.. For normal or near normal incidence, uncertainties plague the measurement of the depth of the etch pit and hence the range of the particle. Through this article we wish to suggest an alternative method of assessment, based on the observation of diffraction rings, of the depth of an etch pit.

  7. Development of transethosomes formulation for dermal fisetin delivery: Box-Behnken design, optimization, in vitro skin penetration, vesicles-skin interaction and dermatokinetic studies.

    Science.gov (United States)

    Moolakkadath, Thasleem; Aqil, Mohd; Ahad, Abdul; Imam, Syed Sarim; Iqbal, Babar; Sultana, Yasmin; Mujeeb, Mohd; Iqbal, Zeenat

    2018-05-07

    The present study was conducted for the optimization of transethosomes formulation for dermal fisetin delivery. The optimization of the formulation was carried out using "Box-Behnken design". The independent variables were Lipoid S 100, ethanol and sodium cholate. The prepared formulations were characterized for vesicle size, entrapment efficiency and in vitro skin penetration study. The vesicles-skin interaction, confocal laser scanning microscopy and dermatokinetic studies were performed with optimized formulation. Results of the present study demonstrated that the optimized formulation presented vesicle size of 74.21 ± 2.65 nm, zeta potential of -11.0 mV, entrapment efficiency of 68.31 ± 1.48% and flux of 4.13 ± 0.17 µg/cm 2 /h. The TEM image of optimized formulation exhibited sealed and spherical shape vesicles. Results of thermoanalytical techniques demonstrated that the prepared transethosomes vesicles formulation had fluidized the rigid membrane of rat's skin for smoother penetration of fisetin transethosomes. The confocal study results presented well distribution and penetration of Rhodamine B loaded transethosomes vesicles formulation up to deeper layers of the rat's skin as compared to the Rhodamine B-hydro alcoholic solution. Present study data revealed that the developed transethosomes vesicles formulation was found to be a potentially useful drug carrier for fisetin dermal delivery.

  8. Experimental and numerical study on penetration of micro/nano diamond particle into metal by underwater shock wave

    Directory of Open Access Journals (Sweden)

    S Tanaka

    2016-09-01

    Full Text Available In order to develop composite materials, new attempting was conducted. When an explosive is exploded in water, underwater shock wave is generated. Metal plate is accelerated by the underwater shock wave and collided with diamond particles at high velocity. In this paper, pure aluminum and magnesium alloy plates are used as matrix. Micro and nano sized diamond particles were used as reinforcement. Micro diamond particles were closely coated on metal surface. Some of micro diamond particles were penetrated into aluminum. Improvement of base metal property (wearing resistance was verified by wear test for recovering metal plate. In order to confirm the deformation of the aluminum plate during the collision with diamond particles, simplified numerical simulation was conducted by using LS-DYNA software. From the result of numerical simulation, large deformation of aluminum and process of particle penetration were verified.

  9. Controlling Force and Depth in Friction Stir Welding

    Science.gov (United States)

    Adams, Glynn; Loftus, Zachary; McCormac, Nathan; Venable, Richard

    2005-01-01

    Feedback control of the penetration force applied to a pin tool in friction stir welding has been found to be a robust and reliable means for controlling the depth of penetration of the tool. This discovery has made it possible to simplify depth control and to weld with greater repeatability, even on workpieces with long weld joints. Prior to this discovery, depths of penetration in friction stir welding were controlled by hard-tooled roller assemblies or by depth actuators controlled by feedback from such external sensors as linear variable-differential transformers or laser-based devices. These means of control are limited: A hard-tooled roller assembly confines a pin tool to a preset depth that cannot be changed easily during the welding process. A measurement by an external sensor is only an indirect indicative of the depth of penetration, and computations to correlate such a measurement with a depth of penetration are vulnerable to error. The present force-feedback approach exploits the proportionality between the depth and the force of penetration Unlike a depth measurement taken by an external sensor, a force measurement can be direct because it can be taken by a sensor coupled directly to the pin tool. The reading can be processed through a modern electronic servo control system to control an actuator to keep the applied penetration force at the desired level. In comparison with the older depth-control methods described above, this method offers greater sensitivity to plasticizing of the workpiece metal and is less sensitive to process noise, resulting in a more consistent process. In an experiment, a tapered panel was friction stir welded while controlling the force of penetration according to this method. The figure is a plot of measurements taken during the experiment, showing that force was controlled with a variation of 200 lb (890 N), resulting in control of the depth of penetration with a variation of 0.004 in. (0.1 mm).

  10. Experimental study on depth of paraffin wax over floating absorber plate in built-in storage solar water heater

    Directory of Open Access Journals (Sweden)

    R Sivakumar

    2015-11-01

    Full Text Available The aim of this article is to study the effect of depth of phase change material over the absorber surface of an integrated collector-storage type flat plate solar water heater. Flat plate solar water heaters are extensively used all over the world to utilize the natural source of solar energy. In order to utilize the solar energy during off-sunshine hours, it is inevitable to store and retain solar thermal energy as long as possible. Here, phase change material is not used for heat storage, but to minimize losses during day and night time only. The depth of phase change material over a fixed depth of water in a solar thermal collector is an important geometric parameter that influences the maximum temperature rise during peak solar irradiation and hence the losses. From the results of the studies for different masses of paraffin wax phase change material layers, the optimum depth corresponding to the maximum heat gain till evening is found to be 2 mm, and the heat retention till the next day morning is found to be 4 mm.

  11. Application of ground penetrating radar in placer mineral exploration for mapping subsurface sand layers: A case study

    Digital Repository Service at National Institute of Oceanography (India)

    Loveson, V.J.; Barnwal, R.P.; Singh, V.K.; Gujar, A.R.; Rajamanickam, G.V.

    radar reflections using time-domain reflectometry and sedimentological analyses, Sedimentology, v. 47, p. 435-449. Jol, H.M. & Bristow, C.S., 2003. GPR in sediments: advice on data collection, basic processing and interpretation, a good practice... guide, In: Bristow, C.S. and Jol, H.M. (Eds.), GPR in sediments, Geological Society of London, Special Publication, 211. Neal, A., 2004. Ground Penetrating Radar and its use in sedimentology: Principles, Problems and Progress. Earth-Science Reviews...

  12. Study of the vitamins A, E and C esters penetration into the skin by confocal Raman spectroscopy in vivo

    Science.gov (United States)

    Mogilevych, Borys; Isensee, Debora; Rangel, Joao L.; Dal Pizzol, Carine; Martinello, Valeska C. A.; Dieamant, Gustavo C.; Martin, Airton A.

    2015-06-01

    Vitamins A, E and C play important role in skin homeostasis and protection. Hence, they are extensively used in many cosmetic and cosmeceutic products. However, their molecules are unstable, and do not easily penetrate into the skin, which drastically decreases its efficiency in topical formulations. Liposoluble derivative of the vitamin A - retinyl palmitate, vitamin E - tocopheryl acetate, and vitamin C - tetraisopalmitoyl ascorbic acid, are more stable, and are frequently used as an active ingredient in cosmetic products. Moreover, increased hydrophobicity of these molecules could lead to a higher skin penetration. The aim of this work is to track and compare the absorption of the liposoluble derivatives of the vitamins and their encapsulated form, into the healthy human skin in vivo. We used Confocal Raman Spectroscopy (CRS) that is proven to be helpful in label-free non-destructive investigation of the biochemical composition and molecular conformational analysis of the biological samples. The measurements were performed in the volar forearm of the 10 healthy volunteers. Skin was treated with both products, and Raman spectra were obtained after 15 min, 3 hours, and 6 hours after applying the formulation. 3510 Skin Composition Analyzer (River Diagnostics, The Netherlands) with 785 nm laser excitation was used to acquire information in the fingerprint region. Significant difference in permeation of the products was observed. Whereas only free form of retinyl palmitate penetrate the skin within first 15 minutes, all three vitamin derivatives were present under the skin surface in case of nanoparticulated form.

  13. A Hybrid Genetic Programming Method in Optimization and Forecasting: A Case Study of the Broadband Penetration in OECD Countries

    Directory of Open Access Journals (Sweden)

    Konstantinos Salpasaranis

    2012-01-01

    Full Text Available The introduction of a hybrid genetic programming method (hGP in fitting and forecasting of the broadband penetration data is proposed. The hGP uses some well-known diffusion models, such as those of Gompertz, Logistic, and Bass, in the initial population of the solutions in order to accelerate the algorithm. The produced solutions models of the hGP are used in fitting and forecasting the adoption of broadband penetration. We investigate the fitting performance of the hGP, and we use the hGP to forecast the broadband penetration in OECD (Organisation for Economic Co-operation and Development countries. The results of the optimized diffusion models are compared to those of the hGP-generated models. The comparison indicates that the hGP manages to generate solutions with high-performance statistical indicators. The hGP cooperates with the existing diffusion models, thus allowing multiple approaches to forecasting. The modified algorithm is implemented in the Python programming language, which is fast in execution time, compact, and user friendly.

  14. The study of mutations of low penetrates candidate genes, participating in appearance of breast cancer in patients from different regions of Belarus

    International Nuclear Information System (INIS)

    Myasnikov, S.O.; Bogdanova, N.V.; Bokut', S.B.; Feshchenko, S.P.

    2003-01-01

    Breast cancer is the most widespread malignancy in the world. It is supposed, that all factors influencing on breast cancer onset can be divided into 4 groups: environmental factors, state of woman's health, heredity and concomitant disease. The inherited disposition towards breast cancer is complex, and many genetic variants and polymorphisms have been postulated to play a role in this condition. Despite genes with a high penetrance, known some genes with a low penetrance, such as ATM, CHEK2 and XRCC4. Ionizing radiation is for long being recognized as a potent carcinogen. The link between exposition to high doses of radiation and a subsequent development of breast cancer has been shown in numerous epidemiological studies. Because mutations in the known genes explain less than half of all multiple-case families, other genes involved in these repair pathways are now under current investigation in many different labs worldwide to define their role in breast cancer predisposition. The purpose of this paper is to study mutations of low penetrate candidate genes, participating in appearance of breast cancer in Byelorussian patients. This study is for the first time reveals the mutations of breast cancer genes in the Byelorussian population. Were used such methods as extraction of DNA, PCR, ARMAS-PCR and restriction analysis for this study. As a result of the work frequent mutations of CHEK2 and XRCC4 were found in family cases. It is shown that following methods are useful for cancer risk prediction for patients and their blood relatives. (authors)

  15. Market penetration rates of new energy technologies

    International Nuclear Information System (INIS)

    Lund, Peter

    2006-01-01

    The market penetration rates of 11 different new energy technologies were studied covering energy production and end-use technologies. The penetration rates were determined by fitting observed market data to an epidemical diffusion model. The analyses show that the exponential penetration rates of new energy technologies may vary from 4 up to over 40%/yr. The corresponding take-over times from a 1% to 50% share of the estimated market potential may vary from less than 10 to 70 years. The lower rate is often associated with larger energy impacts. Short take-over times less than 25 years seem to be mainly associated with end-use technologies. Public policies and subsides have an important effect on the penetration. Some technologies penetrate fast without major support explained by technology maturity and competitive prices, e.g. compact fluorescent lamps show a 24.2%/yr growth rate globally. The penetration rates determined exhibit some uncertainty as penetration has not always proceeded close to saturation. The study indicates a decreasing penetration rate with increasing time or market share. If the market history is short, a temporally decreasing functional form for the penetration rate coefficient could be used to anticipate the probable behavior

  16. Phenotype, genotype, and worldwide genetic penetrance of LRRK2-associated Parkinson's disease: a case-control study

    Science.gov (United States)

    Healy, Daniel G; Falchi, Mario; O'Sullivan, Sean S; Bonifati, Vincenzo; Durr, Alexandra; Bressman, Susan; Brice, Alexis; Aasly, Jan; Zabetian, Cyrus P; Goldwurm, Stefano; Ferreira, Joaquim J; Tolosa, Eduardo; Kay, Denise M; Klein, Christine; Williams, David R; Marras, Connie; Lang, Anthony E; Wszolek, Zbigniew K; Berciano, Jose; Schapira, Anthony HV; Lynch, Timothy; Bhatia, Kailash P; Gasser, Thomas; Lees, Andrew J; Wood, Nicholas W

    2008-01-01

    Summary Background Mutations in LRRK2, the gene that encodes leucine-rich repeat kinase 2, are a cause of Parkinson's disease (PD). The International LRRK2 Consortium was established to answer three key clinical questions: can LRRK2-associated PD be distinguished from idiopathic PD; which mutations in LRRK2 are pathogenic; and what is the age-specific cumulative risk of PD for individuals who inherit or are at risk of inheriting a deleterious mutation in LRRK2? Methods Researchers from 21 centres across the world collaborated on this study. The frequency of the common LRRK2 Gly2019Ser mutation was estimated on the basis of data from 24 populations worldwide, and the penetrance of the mutation was defined in 1045 people with mutations in LRRK2 from 133 families. The LRRK2 phenotype was defined on the basis of 59 motor and non-motor symptoms in 356 patients with LRRK2-associated PD and compared with the symptoms of 543 patients with pathologically proven idiopathic PD. Findings Six mutations met the consortium's criteria for being proven pathogenic. The frequency of the common LRRK2 Gly2019Ser mutation was 1% of patients with sporadic PD and 4% of patients with hereditary PD; the frequency was highest in the middle east and higher in southern Europe than in northern Europe. The risk of PD for a person who inherits the LRRK2 Gly2019Ser mutation was 28% at age 59 years, 51% at 69 years, and 74% at 79 years. The motor symptoms (eg, disease severity, rate of progression, occurrence of falls, and dyskinesia) and non-motor symptoms (eg, cognition and olfaction) of LRRK2-associated PD were more benign than those of idiopathic PD. Interpretation Mutations in LRRK2 are a clinically relevant cause of PD that merit testing in patients with hereditary PD and in subgroups of patients with PD. However, this knowledge should be applied with caution in the diagnosis and counselling of patients. Funding UK Medical Research Council; UK Parkinson's Disease Society; UK Brain Research

  17. Quantifying the Variation in Shear Zone Character with Depth: a Case Study from the Simplon Shear Zone, Central Alps

    Science.gov (United States)

    Cawood, T. K.; Platt, J. P.

    2017-12-01

    A widely-accepted model for the rheology of crustal-scale shear zones states that they comprise distributed strain at depth, in wide, high-temperature shear zones, which narrow to more localized, high-strain zones at lower temperature and shallower crustal levels. We test and quantify this model by investigating how the width, stress, temperature and deformation mechanisms change with depth in the Simplon Shear Zone (SSZ). The SSZ marks a major tectonic boundary in the central Alps, where normal-sense motion and rapid exhumation of the footwall have preserved evidence of older, deeper deformation in rocks progressively further into the currently-exposed footwall. As such, microstructures further from the brittle fault (which represents the most localized, most recently-active part of the SSZ) represent earlier, higher- temperature deformation from deeper crustal levels, while rocks closer to the fault have been overprinted by successively later, cooler deformation at shallower depths. This study uses field mapping and microstructural studies to identify zones representing deformation at various crustal levels, and characterize each in terms of zone width (representing width of the shear zone at that time and depth) and dominant deformation mechanism. In addition, quartz- (by Electron Backscatter Diffraction, EBSD) and feldspar grain size (measured optically) piezometry are used to calculate the flow stress for each zone, while the Ti-in-quartz thermometer (TitaniQ) is used to calculate the corresponding temperature of deformation. We document the presence of a broad zone in which quartz is recrystallized by the Grain Boundary Migration (GBM) mechanism and feldspar by Subgrain Rotation (SGR), which represents the broad, deep zone of deformation occurring at relatively high temperatures and low stresses. In map view, this transitions to successively narrower zones, respectively characterized by quartz SGR and feldspar Bulge Nucleation (BLG); quartz BLG and brittle

  18. Frequency and Magnetic Field Dependence of the Skin Depth in Co-rich Soft Magnetic Microwires

    Directory of Open Access Journals (Sweden)

    A. Zhukov

    2016-11-01

    Full Text Available We studied giant magnetoimpedance (GMI effect in magnetically soft amorphous Co-rich microwires in the extended frequency range. From obtained experimentally dependences of GMI ratio on magnetic field and different frequencies we estimated the penetration depth and its dependence on applied magnetic field and frequency

  19. Experimental Study of the Effect for Water Depth on the Mass Transfer of Passive Solar Still Chemical Solutions

    Directory of Open Access Journals (Sweden)

    Fayadh M. Abed

    2018-01-01

    Full Text Available An experimental study on a passive solar distiller in the Tikrit city on (latitude line"34 36o north, longitude line "45 43o east, and purpose of that study to raise the efficiency and productivity of the solar distiller. And then design the monoclinic solar distiller and add reflector plate and a solar concentrate. The Practical tests were conducted at a rate of every half-hour from the beginning of February to the beginning of the month of June. The study began by comparing the solar distiller that contain the concentrates and without contain it. Then study the influence of adding coal and chemical solutions, like blue Thymol solution and blue bromophenol solution to see the additions effect on the productivity and efficiency of distiller, and also The study was conducted to see the effect of the water depth on the productivity of distiller with take four water depths within the basin are (2,1.5,1,0.5 cm of water. The tests were conducted in weather conditions close. and the results of the study, That distilled added his concentrates improved its productivity by 46% and efficiency increases 43% with non-use of concentrates, and coal increased efficiency by 36% and productivity improved up to 38%, the addition of  blue Thymol solution increases the efficiency by 19% and productivity by 16%, as well as bromophenol solution  increase productivity by 23% and improve efficiency by 25%, when comparing the additions found that the best one is coal. Through the study of the depth of the water show that increases productivity and efficiency by reducing the depth of the water in the basin distiller. DOI: http://dx.doi.org/10.25130/tjes.24.2017.13

  20. Metasploit penetration testing cookbook

    CERN Document Server

    Agarwal, Monika

    2013-01-01

    This book follows a Cookbook style with recipes explaining the steps for penetration testing with WLAN, VOIP, and even cloud computing. There is plenty of code and commands used to make your learning curve easy and quick.This book targets both professional penetration testers as well as new users of Metasploit, who wish to gain expertise over the framework and learn an additional skill of penetration testing, not limited to a particular OS. The book requires basic knowledge of scanning, exploitation, and the Ruby language.

  1. Chloride Penetration through Cracks in High-Performance Concrete and Surface Treatment System for Crack Healing

    Directory of Open Access Journals (Sweden)

    In-Seok Yoon

    2012-01-01

    Full Text Available For enhancing the service life of concrete structures, it is very important to minimize crack at surface. Even if these cracks are very small, the problem is to which extend these cracks may jeopardize the durability of these decks. It was proposed that crack depth corresponding with critical crack width from the surface is a crucial factor in view of durability design of concrete structures. It was necessary to deal with chloride penetration through microcracks characterized with the mixing features of concrete. This study is devoted to examine the effect of high strength concrete and reinforcement of steel fiber on chloride penetration through cracks. High strength concrete is regarded as an excellent barrier to resist chloride penetration. However, durability performance of cracked high strength concrete was reduced seriously up to that of ordinary cracked concrete. Steel fiber reinforcement is effective to reduce chloride penetration through cracks because steel fiber reinforcement can lead to reduce crack depth significantly. Meanwhile, surface treatment systems are put on the surface of the concrete in order to seal the concrete. The key-issue is to which extend a sealing is able to ensure that chloride-induced corrosion can be prevented. As a result, penetrant cannot cure cracks, however, coating and combined treatment can prevent chloride from flowing in concrete with maximum crack width of 0.06 mm and 0.08 mm, respectively.

  2. Cs and Cl penetration estimation in mortar from fly ash of MSWI

    International Nuclear Information System (INIS)

    Yamada, K.; Hosokawa, Y.; Haga, K.; Osako, M.

    2015-01-01

    By the Fukushima Daiichi accident, radioactive Cs was scattered widely in East Japan. From the viewpoint of radionuclide contaminated wastes management, water soluble Cs in the fly ash of incineration of municipal solid wastes (MSWI-FA) is the most serious problem. When final disposal of MSWI-FA contaminated by radioactive Cs in concrete pit is considered, it is necessary to understand the characteristics of MSWI-FA and Cs penetration behavior into concrete. In this study, the expected solution generated from MSWI-FA is analyzed and immersion test of mortar in this model solution was carried out for several kinds of cement and sand types. Cs showed similar penetration profiles with Cl regardless of cement and sand types. By using fly ash cement, the penetration depth of Cs decreased less than half compared to ordinary Portland cement (OPC). Clay mineral in sand did not affect the penetration of Cs possible because of the competing effect of potassium for Cs adsorption. Assuming a diffusion equation considering non-linear binding, from the measured profiles, diffusion coefficient and parameters of binding were obtained by fitting. Then, the Cs and Cl profiles after 30 years are estimated and penetration depths of Cs and Cl were only 15 mm for fly ash mortar. (authors)

  3. Two-Dimensional Depth-Averaged Beach Evolution Modeling: Case Study of the Kizilirmak River Mouth, Turkey

    DEFF Research Database (Denmark)

    Baykal, Cüneyt; Ergin, Ayşen; Güler, Işikhan

    2014-01-01

    investigated by satellite images, physical model tests, and one-dimensional numerical models. The current study uses a two-dimensional depth-averaged numerical beach evolution model, developed based on existing methodologies. This model is mainly composed of four main submodels: a phase-averaged spectral wave......This study presents an application of a two-dimensional beach evolution model to a shoreline change problem at the Kizilirmak River mouth, which has been facing severe coastal erosion problems for more than 20 years. The shoreline changes at the Kizilirmak River mouth have been thus far...... transformation model, a two-dimensional depth-averaged numerical waveinduced circulation model, a sediment transport model, and a bottom evolution model. To validate and verify the numerical model, it is applied to several cases of laboratory experiments. Later, the model is applied to a shoreline change problem...

  4. Tangential Biopsy Thickness versus Lesion Depth in Longitudinal Melanonychia: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Nilton Di Chiacchio

    2012-01-01

    Full Text Available Longitudinal melanonychia can be caused by melanocyte activation (hypermelanosis or proliferation (lentigo, nevus or melanoma. Histopathologic examination is mandatory for suspicious cases of melanomas. Tangential biopsy of the matrix is an elegant technique avoiding nail plate dystrophy, but it was unknown whether the depth of the sample obtained by this method is adequate for histopathologic diagnosis. Twenty-two patients with longitudinal melanonychia striata were submitted to tangential matrix biopsies described by Haneke. The tissue was stained with hematoxylin-eosin and the specimens were measured at 3 distinct points according to the total thickness: largest (A, intermediate (B and narrowest (C then divided into 4 groups according to the histopathologic diagnosis (G1: hypermelanosis; G2: lentigos; G3: nevus; G4: melanoma. The lesions were measured using the same method. The mean specimen/lesion thickness measure values for each group was: G1: 0,59/0,10 mm, G2: 0,67/0,08 mm, G3: 0,52/0,05 mm, G4: 0,58/0,10 mm. The general average thickness for all the specimens/lesions was 0,59/0,08 mm. We concluded that the tangential excision, for longitudinal melanonychia, provides an adequate material for histopathological diagnosis.

  5. Penetration testing with Perl

    CERN Document Server

    Berdeaux, Douglas

    2014-01-01

    If you are an expert Perl programmer interested in penetration testing or information security, this guide is designed for you. However, it will also be helpful for you even if you have little or no Linux shell experience.

  6. penetrating abdominal trauma

    African Journals Online (AJOL)

    gender, mechanism of injury, injury severity scores (ISS), penetrating ... ileus, reduced pulmonary function and loss of muscle mass and function, all of .... pathophysiology and rehabilitation. ... quality of life after surgery for colorectal cancer.

  7. Novel micelle carriers for cyclosporin A topical ocular delivery: in vivo cornea penetration, ocular distribution and efficacy studies.

    Science.gov (United States)

    Di Tommaso, Claudia; Bourges, Jean-Louis; Valamanesh, Fatemeh; Trubitsyn, Gregory; Torriglia, Alicia; Jeanny, Jean-Claude; Behar-Cohen, Francine; Gurny, Robert; Möller, Michael

    2012-06-01

    Cornea transplantation is one of the most performed graft procedures worldwide with an impressive success rate of 90%. However, for "high-risk" patients with particular ocular diseases in addition to the required surgery, the success rate is drastically reduced to 50%. In these cases, cyclosporin A (CsA) is frequently used to prevent the cornea rejection by a systemic treatment with possible systemic side effects for the patients. To overcome these problems, it is a challenge to prepare well-tolerated topical CsA formulations. Normally high amounts of oils or surfactants are needed for the solubilization of the very hydrophobic CsA. Furthermore, it is in general difficult to obtain ocular therapeutic drug levels with topical instillations due to the corneal barriers that efficiently protect the intraocular structures from foreign substances thus also from drugs. The aim of this study was to investigate in vivo the effects of a novel CsA topical aqueous formulation. This formulation was based on nanosized polymeric micelles as drug carriers. An established rat model for the prevention of cornea graft rejection after a keratoplasty procedure was used. After instillation of the novel formulation with fluorescent labeled micelles, confocal analysis of flat-mounted corneas clearly showed that the nanosized carriers were able to penetrate into all corneal layers. The efficacy of a 0.5% CsA micelle formulation was tested and compared to a physiological saline solution and to a systemic administration of CsA. In our studies, the topical CsA treatment was carried out for 14 days, and the three parameters (a) cornea transparency, (b) edema, and (c) neovascularization were evaluated by clinical observation and scoring. Compared to the control group, the treated group showed a significant higher cornea transparency and significant lower edema after 7 and 13 days of the surgery. At the end point of the study, the neovascularization was reduced by 50% in the CsA-micelle treated

  8. Barrier penetration database

    International Nuclear Information System (INIS)

    Fainberg, A.; Bieber, A.M. Jr.

    1978-11-01

    This document is intended to supply the NRC and nuclear power plant licensees with basic data on the times required to penetrate forcibly the types of barriers commonly found in nuclear plants. These times are necessary for design and evaluation of the physical protection system required under 10CFR73.55. Each barrier listed is described in detail. Minor variations in basic barrier construction that result in the same penetration time, are also described

  9. Polyamide nanocapsules and nano-emulsions containing Parsol® MCX and Parsol® 1789: in vitro release, ex vivo skin penetration and photo-stability studies.

    Science.gov (United States)

    Hanno, Ibrahim; Anselmi, Cecilia; Bouchemal, Kawthar

    2012-02-01

    To prepare polyamide nanocapsules for skin photo-protection, encapsulating α-tocopherol, Parsol®MCX (ethylhexyl methoxycinnamate) and/or Parsol®1789 (butyl methoxydibenzoylmethane). Nanocapsules were obtained by combining spontaneous emulsification and interfacial polycondensation reaction between sebacoyl chloride and diethylenetriamine. Nano-emulsions used as control were obtained by the same process without monomers. The influence of carrier on release rate was studied in vitro with a membrane-free model. Epidermal penetration of encapsulated sunscreens was ex vivo evaluated using Franz diffusion cells. Ability of encapsulated sunscreens to improve photo-stability was verified by comparing percentage of degradation after UV radiation exposure. Sunscreen-containing nanocapsules (260-400 nm) were successfully prepared; yield of encapsulation was >98%. Parsol®MCX and Parsol®1789 encapsulation led to decreased release rate by up to 60% in comparison with nano-emulsion and allowed minimum penetration through pig ear epidermis. Presence of polyamide shell protected encapsulated sunscreen filters from photo-degradation without affecting their activity. Encapsulation of Parsol®MCX and Parsol®1789 into oil-core of polyamide nanocapsules allowed protection from photo-degradation, controlled release from nanocapsules, and limited penetration through pig ear epidermis.

  10. Evaluation depth of the curve of Spee in class I, class II, and class III malocclusion: A cross sectional study

    Directory of Open Access Journals (Sweden)

    Sanjna Nayar

    2015-01-01

    Full Text Available Occlusal plane is an essential consideration when multiple long-span posterior restorations are designed. When restorations are added to an existing tooth arrangement characterized by rotated, tipped, or extruded teeth, excursive interferences may be incorporated, resulting in detrimental squeal. The curve of Spee, which exists in the ideal natural dentition, allows harmony to exist between the anterior tooth and condylar guidance. This curve exists in the sagittal plane and is the best viewed from a lateral aspect. It permits total posterior disclusion on mandibular protrusion, given proper anterior tooth guidance. It is unclear that whether the curve of Spee is a description of the occlusal surface of each arch separately or in maximal intercuspation. The purpose of this study was to examine the differences in the depth of curve of Spee between the class I, class II, class III and to investigate the relationship of depth of curve of Spee with over jet, over-bite.

  11. Speech Understanding with a New Implant Technology: A Comparative Study with a New Nonskin Penetrating Baha System

    Directory of Open Access Journals (Sweden)

    Anja Kurz

    2014-01-01

    Full Text Available Objective. To compare hearing and speech understanding between a new, nonskin penetrating Baha system (Baha Attract to the current Baha system using a skin-penetrating abutment. Methods. Hearing and speech understanding were measured in 16 experienced Baha users. The transmission path via the abutment was compared to a simulated Baha Attract transmission path by attaching the implantable magnet to the abutment and then by adding a sample of artificial skin and the external parts of the Baha Attract system. Four different measurements were performed: bone conduction thresholds directly through the sound processor (BC Direct, aided sound field thresholds, aided speech understanding in quiet, and aided speech understanding in noise. Results. The simulated Baha Attract transmission path introduced an attenuation starting from approximately 5 dB at 1000 Hz, increasing to 20–25 dB above 6000 Hz. However, aided sound field threshold shows smaller differences and aided speech understanding in quiet and in noise does not differ significantly between the two transmission paths. Conclusion. The Baha Attract system transmission path introduces predominately high frequency attenuation. This attenuation can be partially compensated by adequate fitting of the speech processor. No significant decrease in speech understanding in either quiet or in noise was found.

  12. Simulation study of a depth-encoding positron emission tomography detector inserting horizontal-striped glass between crystal layers

    Science.gov (United States)

    Kim, Kyu Bom; Choi, Yong; Kang, Jihoon

    2017-10-01

    This study introduces a depth-encoding positron emission tomography (PET) detector inserting a horizontal-striped glass between the pixilated scintillation crystal layers. This design allows light spreading so that scintillation photons can travel only through the X direction and allows alteration in the light distribution so that it can generate a unique pattern diagram of the two-dimensional (2-D) flood histogram that identifies depth position as well as X-Y position of γ-ray interaction. A Monte Carlo simulation was conducted for the assessment of the depth of interaction (DOI)-PET detector. The traced light distribution for each event was converted into the 2-D flood histogram. Light loss caused by inserting the horizontal-striped glass between the crystal layers was estimated. Applicable weighting factors were examined for each DOI-PET detector. No considerable degradation of light loss was observed. The flood histogram, without overlapping of each crystal position, can be generated for the DOI detector based on each crystal block by inserting the horizontal-striped glass with a thickness of >1 mm and the modified resistive charge division networks with applicable weighting factors. This study demonstrated that the proposed DOI-PET detector can extract the three-dimensional γ-ray interaction position without considerable performance degradations of the PET detector from the 2-D flood histogram.

  13. Penetration of gold nanoparticles across the stratum corneum layer of thick-Skin.

    Science.gov (United States)

    Raju, Gayathri; Katiyar, Neeraj; Vadukumpully, Sajini; Shankarappa, Sahadev A

    2018-02-01

    Transdermal particulate penetration across thick-skin, such as that of palms and sole, is particularly important for drug delivery for disorders such as small fiber neuropathies. Nanoparticle-based drug delivery across skin is believed to have much translational applications, but their penetration especially through thick-skin, is not clear. This study specifically investigates the effectiveness of gold nanoparticles (AuNPs) for thick-skin penetration, especially across the stratum corneum (SC) as a function of particle size. The thick-skinned hind-paw of rat was used to characterize depth and distribution of AuNPs of varying sizes, namely, 22±3, 105±11, and 186±20nm. Epidermal penetration of AuNPs was characterized both, in harvested skin from the hind-paw using a diffusion chamber, as well as in vivo. Harvested skin segments exposed to 22nm AuNPs for only 3h demonstrated higher penetration (pthick-skin allows nanoparticle penetration and acts as a depot for release of AuNPs into circulation long after the initial exposure has ceased. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  14. Monitoring Induced Fractures with Electrical Measurements using Depth to Surface Resistivity: A Field Case Study

    Science.gov (United States)

    Wilt, M.; Nieuwenhuis, G.; Sun, S.; MacLennan, K.

    2016-12-01

    Electrical methods offer an attractive option to map induced fractures because the recovered anomaly is related to the electrical conductivity of the injected fluid in the open (propped) section of the fracture operation. This is complementary to existing micro-seismic technology, which maps the mechanical effects of the fracturing. In this paper we describe a 2014 field case where a combination of a borehole casing electrode and a surface receiver array was used to monitor hydrofracture fracture creation and growth in an unconventional oil field project. The fracture treatment well was 1 km long and drilled to a depth of 2.2 km. Twelve fracture events were induced in 30 m intervals (stages) in the 1 km well. Within each stage 5 events (clusters) were initiated at 30 m intervals. Several of the fracture stages used a high salinity brine, instead of fresh water, to enhance the electrical signal. The electrical experiment deployed a downhole source in a well parallel to the treatment well and 100 m away. The source consisted of an electrode attached to a wireline cable into which a 0.25 Hz square wave was injected. A 60-station electrical field receiver array was placed above the fracture and extending for several km. Receivers were oriented to measure electrical field parallel with the presumed fracture direction and those perpendicular to it. Active source electrical data were collected continuously during 7 frac stages, 3 of which used brine as the frac fluid over a period of several days. Although the site was quite noisy and the electrical anomaly small we managed to extract a clear frac anomaly using field separation, extensive signal averaging and background noise rejection techniques. Preliminary 3D modeling, where we account for current distribution of the casing electrode and explicitly model multiple thin conductive sheets to represent fracture stages, produces a model consistent with the field measurements and also highlights the sensitivity of the

  15. In vitro investigation of the follicular penetration of porcine ear skin using a nanoparticle-emulsion containing the antiseptic polihexanide In vitro investigation of the follicular penetration of porcine ear skin

    Science.gov (United States)

    Ulmer, M.; Patzelt, A.; Vergou, T.; Lademann, J.; Richter, H.; Kramer, A.; Müller, G.; Sterry, W.; Lange-Asschenfeldt, B.

    2012-05-01

    Earlier investigations regarding the distribution of the bacterial flora on the human skin demonstrate that the hair follicle acts as a bacterial reservoir, providing a quick source for secondary recontamination. These findings highlight the importance of the hair follicle as a target for modern antiseptics. In the present study, we have assessed the follicular penetration of a curcumin-labeled particle-associated antiseptic into porcine skin by laser scanning microscopy. Therefore, the follicular penetration depth of the curcumin-labeled particle-associated antiseptic was compared to the follicular penetration depth of curcumin-labeled particles without antiseptic. The investigation was performed in vitro using porcine skin biopsies. By superposition of the images acquired in the transmission and the fluorescent modus, it was possible to visualize the distribution of the fluorescent dye inside the hair follicles. Quantitative and qualitative results showed that both dispersions penetrated efficiently into the hair follicles. The average penetration depth of the particles with attached antiseptic polihexanide was significantly higher than that of particles without the attached antiseptic. Also, whilst very little sample preparation was needed, laser scanning microscopy was found to be an efficient tool to visualize the skin relief and in particular the hair follicle shaft and localize fluorescent markers within the skin tissue and hair follicles.

  16. Analysis of Reactor Vessel Lower Head Penetration Tube Failure

    International Nuclear Information System (INIS)

    Stempniewicz, Marek

    1999-01-01

    This paper presents results of two studies, performed to investigate the behavior of the reactor vessel penetration tubes in case of relocation of molten material into the tubes. The first study is on the CORVIS drain line experiment 03/1. Results of pre-test calculations are presented, and compared to the later obtained experimental data. The timing of the drain line melting and the velocity of the debris flowing inside the drain line were predicted correctly, but the penetration depth was clearly underestimated. If the calculations are done using different correlation for the melt-to-wall convective heat transfer, the results are closer to the experiment. It cannot however be concluded that the alternative correlation is more appropriate until other uncertainties are clarified. The second study presents calculations performed for GKN Dodewaard CRD, instrument tubes and drain line. Calculations were performed to estimate whether the tubes have a chance to withstand the first attack of the melt and thus postpone vessel failure until the water in the lower plenum evaporates. Calculations were performed assuming that the melt can move into the tubes without any resistance, e.g. presence of water in the tubes was not taken into account. The results indicate that the critical penetration of the GKN vessel, which is most likely to fail, is the drain line. Results also indicate that external flooding should prevent early tube failure, at least in case of low vessel pressure. (author)

  17. In vitro investigation of the follicular penetration of porcine ear skin using a nanoparticle-emulsion containing the antiseptic polihexanide

    International Nuclear Information System (INIS)

    Ulmer, M; Patzelt, A; Lademann, J; Richter, H; Sterry, W; Lange-Asschenfeldt, B; Vergou, T; Kramer, A; Mueller, G

    2012-01-01

    Earlier investigations regarding the distribution of the bacterial flora on the human skin demonstrate that the hair follicle acts as a bacterial reservoir, providing a quick source for secondary recontamination. These findings highlight the importance of the hair follicle as a target for modern antiseptics. In the present study, we have assessed the follicular penetration of a curcumin-labeled particle-associated antiseptic into porcine skin by laser scanning microscopy. Therefore, the follicular penetration depth of the curcumin-labeled particle-associated antiseptic was compared to the follicular penetration depth of curcumin-labeled particles without antiseptic. The investigation was performed in vitro using porcine skin biopsies. By superposition of the images acquired in the transmission and the fluorescent modus, it was possible to visualize the distribution of the fluorescent dye inside the hair follicles. Quantitative and qualitative results showed that both dispersions penetrated efficiently into the hair follicles. The average penetration depth of the particles with attached antiseptic polihexanide was significantly higher than that of particles without the attached antiseptic. Also, whilst very little sample preparation was needed, laser scanning microscopy was found to be an efficient tool to visualize the skin relief and in particular the hair follicle shaft and localize fluorescent markers within the skin tissue and hair follicles

  18. A view to the intermediate-depth Vrancea earthquake of May 30, 1990: Case study in NE Bulgaria

    International Nuclear Information System (INIS)

    Kouteva, M.; Paskaleva, I.; Panza, G.F.; Romanelli, F.

    2004-02-01

    A deterministic analytical procedure for ground motion modelling, combining both modal summation and mode coupling techniques has been implemented to obtain synthetic seismic signals at Russe, NE Bulgaria, due to one of the strongest Vrancea intermediate-depth earthquakes, which occurred during the last century, May 30, 1990. The frequency content of the synthetic signals in different frequency ranges, up to 1 and 2Hz, has been studied separately. The results of this study, i.e. time histories and related ground motions parameters, can be used for different earthquake engineering analyses, e.g. structural performance assessments. (author)

  19. Ice volume changes (1936–1990–2007 and ground-penetrating radar studies of Ariebreen, Hornsund, Spitsbergen

    Directory of Open Access Journals (Sweden)

    Javier Lapazaran

    2013-08-01

    Full Text Available Ariebreen is a small (0.37 km2-valley glacier located in southern Spitsbergen. Our ground-penetrating radar surveys of the glacier show that it is less than 30 m thick on average, with a maximum thickness of 82 m, and it appears to be entirely cold. By analysing digital terrain models of the ice surface from different dates, we determine the area and volume changes during two periods, 1936–1990 and 1990–2007. The total ice volume of the glacier has decreased by 73% during the entire period 1936–2007, which is equivalent to a mean mass balance rate of −0.61±0.17 m y−1 w.eq. The glacier thinning rate has increased markedly between the first and second periods, from −0.50±0.22 to −0.95±0.17 m y−1 w.eq.

  20. Penetration portion shielding structure

    International Nuclear Information System (INIS)

    Hayashi, Katsumi; Narita, Hitoshi; Handa, Hiroyuki; Takeuchi, Jun; Tozuka, Fumio.

    1994-01-01

    Openings of a plurality of shieldings for penetration members are aligned to each other, and penetration members are inserted from the openings. Then, the openings of the plurality of shielding members are slightly displaced with each other to make the penetration portions into a helical configuration, so that leakage of radiation is reduced. Upon removal of the members, reverse operation is conducted. When a flowable shielding material is used, the penetration portions are constituted with two plates having previously formed openings and pipes for connecting the openings with each other and a vessel covering the entire of them. After passing the penetration members such as a cable, the relative position of the two plates is changed by twisting, to form a helical configuration which reduces radiation leakage. Since they are bent into the helical configuration, shielding performance is extremely improved compared with a case that radiation leakage is caused from an opening of a straight pipe. In addition, since they can be returned to straight pipes, attachment, detachment and maintenance can be conducted easily. (N.H.)

  1. MDCT diagnosis of penetrating diaphragm injury

    Energy Technology Data Exchange (ETDEWEB)

    Bodanapally, Uttam K.; Shanmuganathan, Kathirkamanathan; Mirvis, Stuart E.; Sliker, Clint W.; Fleiter, Thorsten R.; Sarada, Kamal; Miller, Lisa A. [University of Maryland School of Medicine, Department of Diagnostic Radiology, Baltimore, MD (United States); Stein, Deborah M. [University of Maryland, Department of Surgery, Shock Trauma Center, Baltimore, MD (United States); Alexander, Melvin [National Study Center for Trauma and Emergency Medical Systems, Baltimore, MD (United States)

    2009-08-15

    The purpose of the study was to determine the diagnostic sensitivity and specificity of multidetector CT (MDCT) in detection of diaphragmatic injury following penetrating trauma. Chest and abdominal CT examinations performed preoperatively in 136 patients after penetrating trauma to the torso with injury trajectory in close proximity to the diaphragm were reviewed by radiologists unaware of surgical findings. Signs associated with diaphragmatic injuries in penetrating trauma were noted. These signs were correlated with surgical diagnoses, and their sensitivity and specificity in assisting the diagnosis were calculated. CT confirmed diaphragmatic injury in 41 of 47 injuries (sensitivity, 87.2%), and an intact diaphragm in 71 of 98 patients (specificity, 72.4%). The overall accuracy of MDCT was 77%. The most accurate sign helping the diagnosis was contiguous injury on either side of the diaphragm in single-entry penetrating trauma (sensitivity, 88%; specificity, 82%). Thus MDCT has high sensitivity and good specificity in detecting penetrating diaphragmatic injuries. (orig.)

  2. MDCT diagnosis of penetrating diaphragm injury

    International Nuclear Information System (INIS)

    Bodanapally, Uttam K.; Shanmuganathan, Kathirkamanathan; Mirvis, Stuart E.; Sliker, Clint W.; Fleiter, Thorsten R.; Sarada, Kamal; Miller, Lisa A.; Stein, Deborah M.; Alexander, Melvin

    2009-01-01

    The purpose of the study was to determine the diagnostic sensitivity and specificity of multidetector CT (MDCT) in detection of diaphragmatic injury following penetrating trauma. Chest and abdominal CT examinations performed preoperatively in 136 patients after penetrating trauma to the torso with injury trajectory in close proximity to the diaphragm were reviewed by radiologists unaware of surgical findings. Signs associated with diaphragmatic injuries in penetrating trauma were noted. These signs were correlated with surgical diagnoses, and their sensitivity and specificity in assisting the diagnosis were calculated. CT confirmed diaphragmatic injury in 41 of 47 injuries (sensitivity, 87.2%), and an intact diaphragm in 71 of 98 patients (specificity, 72.4%). The overall accuracy of MDCT was 77%. The most accurate sign helping the diagnosis was contiguous injury on either side of the diaphragm in single-entry penetrating trauma (sensitivity, 88%; specificity, 82%). Thus MDCT has high sensitivity and good specificity in detecting penetrating diaphragmatic injuries. (orig.)

  3. Performance evaluation of lunar penetrating radar onboard the rover of CE-3 probe based on results from ground experiments

    Science.gov (United States)

    Zhang, Hong-Bo; Zheng, Lei; Su, Yan; Fang, Guang-You; Zhou, Bin; Feng, Jian-Qing; Xing, Shu-Guo; Dai, Shun; Li, Jun-Duo; Ji, Yi-Cai; Gao, Yun-Ze; Xiao, Yuan; Li, Chun-Lai

    2014-12-01

    Lunar Penetrating Radar (LPR) onboard the rover that is part of the Chang'e-3 (CE-3) mission was firstly utilized to obtain in situ measurements about geological structure on the lunar surface and the thickness of the lunar regolith, which are key elements for studying the evolutional history of lunar crust. Because penetration depth and resolution of LPR are related to the scientific objectives of this mission, a series of ground-based experiments using LPR was carried out, and results of the experimental data were obtained in a glacial area located in the northwest region of China. The results show that the penetration depth of the first channel antenna used for LPR is over 79 m with a resolution of 2.8 m, and that for the second channel antenna is over 50.8 m with a resolution of 17.1 cm.

  4. Performance evaluation of lunar penetrating radar onboard the rover of CE-3 probe based on results from ground experiments

    International Nuclear Information System (INIS)

    Zhang Hong-Bo; Zheng Lei; Su Yan; Feng Jian-Qing; Xing Shu-Guo; Dai Shun; Li Jun-Duo; Xiao Yuan; Li Chun-Lai; Fang Guang-You; Zhou Bin; Ji Yi-Cai; Gao Yun-Ze

    2014-01-01

    Lunar Penetrating Radar (LPR) onboard the rover that is part of the Chang'e-3 (CE-3) mission was firstly utilized to obtain in situ measurements about geological structure on the lunar surface and the thickness of the lunar regolith, which are key elements for studying the evolutional history of lunar crust. Because penetration depth and resolution of LPR are related to the scientific objectives of this mission, a series of ground-based experiments using LPR was carried out, and results of the experimental data were obtained in a glacial area located in the northwest region of China. The results show that the penetration depth of the first channel antenna used for LPR is over 79 m with a resolution of 2.8 m, and that for the second channel antenna is over 50.8 m with a resolution of 17.1 cm

  5. Analysis of the penetration of a caffeine containing shampoo into the hair follicles by in vivo laser scanning microscopy

    Science.gov (United States)

    Lademann, J.; Richter, H.; Schanzer, S.; Klenk, A.; Sterry, W.; Patzelt, A.

    2010-02-01

    In previous in vitro investigations, it was demonstrated that caffeine is able to stimulate the hair growth. Therefore, a penetration of caffeine into the hair follicle is necessary. In the present study, in vivo laser scanning microscopy (LSM) was used to investigate the penetration and storage of a caffeine containing shampoo into the hair follicles. It was shown that a 2-min contact time of the shampoo with the skin was enough to accumulate significant parts of the shampoo in the hair follicles. A penetration of the shampoo up to a depth of approx. 200 μm could be detected, which represents the detection limit of the LSM. At this depth, the close network of the blood capillaries surrounding the hair follicles commences. Even after 24 h, the substance was still detectable in the hair follicles. This demonstrates the long-term reservoir function of the hair follicles for topically applied substances such as caffeine.

  6. Centurial Changes in the Depth Conditions of a Regulated River: Case Study of the Lower Tisza River, Hungary

    Directory of Open Access Journals (Sweden)

    Amissah Gabriel Jonathan

    2017-04-01

    Full Text Available The Tisza River is the largest tributary of the Danube in Central Europe, and has been subjected to various human interventions including cutoffs to increase the slope, construction of levees to restrict the floodplain, and construction of groynes and revetments to stabilize the channel. These interventions have altered the natural morphological evolution of the river. The aim of the study is to assess the impacts of these engineering works, employing hydrological surveys of 36 cross sections (VO of the Lower Tisza River for the years of 1891, 1931, 1961, 1976 and 1999. The changes in mean depth and thalweg depth were studied in detail comparing three reaches of the studied section. In general, the thalweg incised during the studied period (1891-1931: 3 cm/y; 1931-1961: 1.3 cm/y and 1976-1999: 2.3 cm/y, except from 1961-1976 which was characterized by aggradation (2 cm/y. The mean depth increased, referring to an overall deepening of the river during the whole period (1891-1931: 1.4 cm/y; 1931-1961: 1.2 cm/y; 1961-1976: 0.6 cm/y and 1976-1999: 1.6 cm/y. The thalweg shifted more in the upper reach showing less stabile channel, while the middle and lower reaches had more stable thalweg. Although the cross-sections subjected to various human interventions experienced considerable incision in the short-term, the cross-sections free from direct human impact experienced the largest incision from 1891-1999, especially along the meandering sections.

  7. Multifractal detrended cross correlation analysis of neuro-degenerative diseases-An in depth study

    Science.gov (United States)

    Dutta, Srimonti; Ghosh, Dipak; Chatterjee, Sucharita

    2018-02-01

    This work revisits our previous study on human gait diseases, (Dutta et al., 2013) where we have studied the autocorrelation of human gait pattern in normal and diseased set. Significant difference in results was observed for normal and diseased set. However we were not able to distinguish between sets of Parkinson's and Huntington's disease. In this paper we attempt to study whether cross correlations between two feet of human gait pattern can help to distinguish between different diseased set. The results reveal that study of cross correlations can help to distinguish between Parkinson's and Huntington's disease.

  8. Qualitative in-depth interviews: Studying religious meaning-making in MMOs

    NARCIS (Netherlands)

    S.D. Aupers (Stef); J.C.F. Schaap (Julian); L. de Wildt (Lars)

    2018-01-01

    markdownabstractIn this chapter, Stef Aupers, Julian Schaap, and Lars de Wildt argue that a “game-centered” orientation in the study of religion and video games (studying in-game religious narratives, discourses, and game rules) should be complemented with a “player-centered” perspective. They call

  9. Depth study of insular shelf electric sounding in the Las Mercedes anomaly (Tacuarembo)

    International Nuclear Information System (INIS)

    Cicalese, H.

    1983-01-01

    In the framework of Uranium prospecting Programme the geophysics team composed by BRGM and DINAMIGE workers were carried out an study about insular shelf electric sounding on the Mercedes area.They were studied the following topics: geographical location, geologic framework, methods, materials and some results

  10. Deformation analysis of shallow penetration in clay

    Science.gov (United States)

    Sagaseta, C.; Whittle, A. J.; Santagata, M.

    1997-10-01

    A new method of analysis is described for estimating the deformations and strains caused by shallow undrained penetration of piles and caissons in clay. The formulation combines previous analyses for steady, deep penetration, with methods used to compute soil deformations due to near-surface ground loss, and is referred to as the Shallow Strain Path Method (SSPM). Complete analytical solutions for the velocity and strain rates are given for a planar wall, an axisymmetric, closed-ended pile and unplugged, open-ended pile geometries. In these examples, the analyses consider a single source penetrating through the soil at a constant rate, generating a family of penetrometers with rounded tips, referred to as simple wall, pile and tube geometries. Soil deformations and strains are obtained by integrating the velocity and strain rates along the particle paths.The transition from shallow to deep penetration is analysed in detail. Shallow penetration causes heave at the ground surface, while settlements occur only in a thin veneer of material adjacent to the shaft and in a bulb-shaped region around the tip. The size of this region increases with the embedment depth. Deformations inside an open-ended pile/caisson are affected significantly by details of the simple tube wall geometry.

  11. Akon - A Penetrator for Europa

    Science.gov (United States)

    Jones, Geraint

    2016-04-01

    Jupiter's moon Europa is one of the most intriguing objects in our Solar System. This 2000km-wide body has a geologically young solid water ice crust that is believed to cover a global ocean of liquid water. The presence of this ocean, together with a source of heating through tidal forces, make Europa a conceivable location for extraterrestrial life. The science case for exploring all aspects of this icy world is compelling. NASA has selected the Europa Mission (formerly Europa Clipper) to study Europa in detail in the 2020s through multiple flybys, and ESA's JUICE mission will perform two flybys of the body in the 2030s. The US agency has extended to the European Space Agency an invitation to provide a contribution to their mission. European scientists interested in Europa science and exploration are currently organizing themselves, in the framework of a coordinated Europa M5 Inititative to study concurrently the main options for this ESA contribution, from a simple addition of individual instruments to the NASA spacecraft, to a lander to investigate Europa's surface in situ. A high speed lander - a penetrator - is by far the most promising technology to achieve this latter option within the anticipated mass constraints, and studies of such a hard lander, many funded by ESA, are now at an advanced level. An international team to formally propose an Europa penetrator to ESA in response to the anticipated ESA M5 call is growing. The working title of this proposal is Akon (Άκων), named after the highly accurate javelin gifted to Europa by Zeus in ancient Greek mythology. We present plans for the Akon penetrator, which would impact Europa's surface at several hundred metres per second, and travel up to several metres into the moon's subsurface. To achieve this, the penetrator would be delivered to the surface by a dedicated descent module, to be destroyed on impact following release of the penetrator above the surface. It is planned that the instruments to be

  12. Ground penetrating radar

    CERN Document Server

    Daniels, David J

    2004-01-01

    Ground-penetrating radar has come to public attention in recent criminal investigations, but has actually been a developing and maturing remote sensing field for some time. In the light of recent expansion of the technique to a wide range of applications, the need for an up-to-date reference has become pressing. This fully revised and expanded edition of the best-selling Surface-Penetrating Radar (IEE, 1996) presents, for the non-specialist user or engineer, all the key elements of this technique, which span several disciplines including electromagnetics, geophysics and signal processing. The

  13. Governing and Managing Customer-initiated Engineering Change – An in-depth case study of a global industrial supplier

    DEFF Research Database (Denmark)

    Sommer, Anita Friis; Storbjerg, Simon Haahr; Dukovska-Popovska, Iskra

    2013-01-01

    or externally by for instance customers. Managing initiated engineering changes is a vital source for improving product performance and radically reducing change costs. Customer-initiated engineering change is an area growing in importance decreasing product life cycles and increasing demand for customisation....... Through an in-depth case study, this paper investigates which process and what governance setup is appropriate to manage customer initiated engineering changes, referred to as request management. The paper includes a proposal for a request management framework and a task-based iterative process model...

  14. Assessing high wind energy penetration

    DEFF Research Database (Denmark)

    Tande, J.O.

    1995-01-01

    In order to convincingly promote installing wind power capacity as a substantial part of the energy supply system, a set of careful analyses must be undertaken. This paper applies a case study concentrated on assessing the cost/benefit of high wind energy penetration. The case study considers...... expanding the grid connected wind power capacity in Praia, the capital of Cape Verde. The currently installed 1 MW of wind power is estimated to supply close to 10% of the electric energy consumption in 1996. Increasing the wind energy penetration to a higher level is considered viable as the project...... with the existing wind power, supply over 30% of the electric consumption in 1996. Applying the recommended practices for estimating the cost of wind energy, the life-cycle cost of this 2.4 MW investment is estimated at a 7% discount rate and a 20 year lifetime to 0.26 DKK/kW h....

  15. Forestry applications of ground-penetrating radar

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzo, H.; Perez-Gracia, V.; Novo, A.; Armesto, J.

    2010-07-01

    Ground-penetrating radar (GPR) is a geophysical and close-range remote sensing technique based on the use of radar pulses to obtain cross-section images of underground features. This method is characterized by the transmission of an electromagnetic short length pulse (1-2 ns), presenting a centre frequency ranging from 10 MHz to 2.5 GHz. The principles of GPR operation are based on the ability of low frequency radar waves to penetrate into a non-conductive medium, usually subsoil, but also walls, concrete or wood. Those waves are detected after suffering a reflection in electromagnetic discontinuities of the propagation medium. Therefore, this is a suitable method to study changes in those physical properties, and also to characterize different mediums and the reflective targets providing information about their physical properties. The aim of this work is to describe and demonstrate different applications of GPR in forestry, showing the obtained results together with their interpretation. Firstly, in this paper, it is illustrated how GPR is able to map shallow bedrock, subsoil stratigraphy and also to estimate shallow water table depth. Secondly, different tree trunks as well as dry timber are analyzed, evaluating the different radar data obtained in each particular case, and observing differences in their electromagnetic properties related to the GPR response. Finally, several measurements were taken in order to analyze the use of GPR to detect tree root systems using polarimetric techniques, being possible to detect medium and big size roots, together with groups of small roots. (Author) 39 refs.

  16. Hydrodynamic analysis and design of high-level radioactive waste disposal model penetrators

    International Nuclear Information System (INIS)

    Visintini, L.; Mazazzi, R.; Murray, C.N.

    1991-01-01

    The Commission of the European Communities is studying in the framework of the NEA/OECD Internationally Co-ordinational Seabed Programme the feasibility of using deep ocean sedimentary geological formations as a final disposal medium for vitrified high level waste and fuel elements. At present, two options are being considered for the embedment of such wastes in the sediment column, drilling and free fall penetrators. In the second case, the high level waste would be contained in specially designed drums which would be placed into torpedo-shaped projectiles. These penetrators would then be launched from a semi-submersible platform or ship and allowed to fall freely through the water column (≅ 5 km depth) and to bury themselves within the sediment column. The present article reports some work which has been carried out by the Joint Research Centre, Ispra Establishment on designing large model penetrators for tests at two sites in the North Atlantic

  17. Performance of kevlar fibre-reinforced rubber composite armour against shaped-charge jet penetration

    Directory of Open Access Journals (Sweden)

    Xu-dong Zu

    Full Text Available AbstractThe protective capability of the Kevlar fibre-reinforced rubber composite armour (KFRRCA at different obliquities is studied using depth-of-penetration experiments method against a 56 mm-diameter standard-shaped charge. Efficiency factors are calculated to evaluate the protection capability of the KFRRCA at different obliquities. Meanwhile, an X-ray experiment is used to observe the deformation, fracture, and scatter of the shaped-charge jet as it penetrates the composite armour. Finally, scanning electron microscopy (SEM is used to analyse the effect of the Kevlar fibre-reinforced rubber for the composite armour to resist jet penetration. The results showed that the KFEECA can be used as additional armour, because it has excellent protection capability, and it can disturb the stability of the middle part of the shaped charge jet (SCJ obviously especially when the armour at 30°and 68° obliquities.

  18. Modeling of Oblique Penetration into Geologic Targets Using Cavity Expansion Penetrator Loading with Target free-Surface Effects

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joe; Longcope, Donald B.; Tabbara, Mazen R.

    1999-05-03

    A procedure has been developed to represent the loading on a penetrator and its motion during oblique penetration into geologic media. The penetrator is modeled with the explicit dynamics, finite element computer program PRONTO 3D and the coupled pressure on the penetrator is given in a new loading option based on a separate cavity expansion (CE) solution that accounts for the pressure-reduction from a nearby target free surface. The free-surface influ- ence distance is selected in a predictive manner by considering the pressure to expand a spherical cavity in a finite radius sphere of the target material. The CE/PRONTO 3D procedure allows a detailed description of the penetrator for predicting shock environments or structural failure dur- ing the entire penetration event and is sufficiently rapid to be used in design optimization. It has been evaluated by comparing its results with data from two field tests of a full-scale penetrator into frozen soil at an impact angles of 49.6 and 52.5 degrees from the horizontal. The measured penetrator rotations were 24 and 22 degrees, respectively. In the simulation, the rotation was21 degrees and predominately resulted from the pressure reduction of the free surface. Good agree- ment was also found for the penetration depth and axial and lateral acceleration at two locations in the penetrator.

  19. Depth study of insular shelf electric sounding in the Puntas de Abrojal anomaly

    International Nuclear Information System (INIS)

    Cicalese, H.

    1983-01-01

    In the framework of the Uranium prospecting Programme, a geophysics team composed by BRGM and DINAMIGE workers were carried out an study about of insular shelf electric sounding on the Puntas de Abrojal area.A geographical location, geologic framework, geophysical survey and methods, materials and results were given

  20. An In-Depth Study on the Impact of External Quality Assurance

    Science.gov (United States)

    Stensaker, Bjorn; Langfeldt, Liv; Harvey, Lee; Huisman, Jeroen; Westerheijden, Don

    2011-01-01

    After more than two decades of external quality assurance, there is an increasing interest in questions concerning the impact and effects of this activity. Following an external evaluation of NOKUT--the Norwegian quality assurance agency, this article studies the impact of external quality assurance in detail by analysing quantitative and…

  1. Baseboard depth study by electrical soundings between Centurion and Noblia (Cerro Largo)

    International Nuclear Information System (INIS)

    Bernard, J.

    1983-11-01

    This study gives an idea of the structure of the sedimentary basin between Noblia and Centurion. Appeared a rise area of baseboard (200 m.) in correlation with a heavy shaft gravimetry. To have a more precise knowledge of the area would be necessary to increase the density of drilling in areas of outcrops of the Tres Islas formation to know its resistivity

  2. Control of penetration zone GMAW

    Directory of Open Access Journals (Sweden)

    Віталій Петрович Iванов

    2016-11-01

    Full Text Available Thermal properties of the base metal, shielding medium and the nature of the electrode metal transfer to a great extent determine the penetration area formation in gas-arc welding. It is not always possible to take into account the influence of these factors on penetration front forming within the existing models. The aim of the work was to research the penetration area forming in gas-arc welding. The research of the penetration area forming in gas-arc welding of CrNi austenitic steels was made. The parameters of the regime as well as the kind of the gaseous medium influence on the formation of the penetration zone were studied. The article shows a linear proportional relationship between the electrode feed rate and the size of the base metal plate. The penetration area formation mode for welding in argon and carbon dioxide have been worked out. Diameter, feed rate and the speed of the electrode movement have been chosen as the main input parameters. Multiple regression analysis method was used to make up the modes. The relations of the third order that make it possible to take into account the electrode metal transfer and thermal properties change of the materials to be welded were used. These relationships show quite good agreement with the experimental measurements in the calculation of the fusion zone shape with consumable electrode in argon and carbon dioxide. It was determined that the shape of the melting front curve can be shown as a generalized function in which the front motion parameters depend on feed rate and the diameter of the electrode. Penetration zone growth time is determined by the welding speed and is calculated as a discrete function of the distance from the electrode with the spacing along the movement coordinate. The influence of the mode parameters on the formation of the fusion zone has been investigated and the ways to manage and stabilize the weld pool formation have been identified. The modes can be used to develop

  3. Mobile Termination and Mobile Penetration

    OpenAIRE

    Hurkens, Sjaak; Jeon, Doh-Shin

    2009-01-01

    In this paper, we study how access pricing affects network competition when subscription demand is elastic and each network uses non-linear prices and can apply termination-based price discrimination. In the case of a fixed per minute termination charge, we find that a reduction of the termination charge below cost has two oppos- ing effects: it softens competition but helps to internalize network externalities. The former reduces mobile penetration while the latter boosts it. We find that fi...

  4. Mobile termination and mobile penetration

    OpenAIRE

    Hurkens, Sjaak

    2009-01-01

    In this paper, we study how access pricing affects network competition when subscription demand is elastic and each network uses non-linear prices and can apply termination-based price discrimination. In the case of a fixed per minute termination charge, we find that a reduction of the termination charge below cost has two opposing effects: it softens competition but helps to internalize network externalities. The former reduces mobile penetration while the latter boosts it. We find that firm...

  5. Screening for trace explosives by AccuTOF™-DART®: an in-depth validation study.

    Science.gov (United States)

    Sisco, Edward; Dake, Jeffrey; Bridge, Candice

    2013-10-10

    Ambient ionization mass spectrometry is finding increasing utility as a rapid analysis technique in a number of fields. In forensic science specifically, analysis of many types of samples, including drugs, explosives, inks, bank dye, and lotions, has been shown to be possible using these techniques [1]. This paper focuses on one type of ambient ionization mass spectrometry, Direct Analysis in Real Time Mass Spectrometry (DART-MS or DART), and its viability as a screening tool for trace explosives analysis. In order to assess viability, a validation study was completed which focused on the analysis of trace amounts of nitro and peroxide based explosives. Topics which were studied, and are discussed, include method optimization, reproducibility, sensitivity, development of a search library, discrimination of mixtures, and blind sampling. Advantages and disadvantages of this technique over other similar screening techniques are also discussed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Father Identity, Involvement and Work–Family Balance: An In-depth Interview Study

    OpenAIRE

    McLaughlin, Katrina; Muldoon, Orla

    2014-01-01

    Work and family roles have changed considerably in the past number of decades. Fathers are now expected to fulfil the role of 'new father' that involves actively caring and sharing in child rearing and, at the same time, maintain commitment to their occupational role. As a consequence, men are subject to the same pressure that women were when they initially entered the workplace decades ago and indeed still are today. This study aims to explore the meanings fathers attach to their life roles,...

  7. An in-depth study of sparse codes on abnormality detection

    DEFF Research Database (Denmark)

    Ren, Huamin; Pan, Hong; Olsen, Søren Ingvor

    2016-01-01

    Sparse representation has been applied successfully in abnormal event detection, in which the baseline is to learn a dictionary accompanied by sparse codes. While much emphasis is put on discriminative dictionary construction, there are no comparative studies of sparse codes regarding abnormality...... are carried out from various angles to better understand the applicability of sparse codes, including computation time, reconstruction error, sparsity, detection accuracy, and their performance combining various detection methods. The experiment results show that combining OMP codes with maximum coordinate...

  8. Verification of Sulfate Attack Penetration Rates for Saltstone Disposal Unit Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Flach, G. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-05-12

    Recent Special Analysis modeling of Saltstone Disposal Units consider sulfate attack on concrete and utilize degradation rates estimated from Cementitious Barriers Partnership software simulations. This study provides an independent verification of those simulation results using an alternative analysis method and an independent characterization data source. The sulfate penetration depths estimated herein are similar to the best-estimate values in SRNL-STI-2013-00118 Rev. 2 and well below the nominal values subsequently used to define Saltstone Special Analysis base cases.

  9. Performance of carbon fiber reinforced rubber composite armour against shaped charge jet penetration

    OpenAIRE

    Yue Lian-yong; Li Wei; Zu Xu-dong; Huang Zheng-xiang; Gao Zhen-yu

    2016-01-01

    Natural rubber is reinforced with carbon fiber; the protective performances of the carbonfiber reinforced rubber composite armour to shaped charge jet have been studied based on the depth of penetration experiments. The craters on the witness blocks, the nature rubber based composite plates’ deformation and the Scanning Electron Microscopy for the hybrid fiber reinforced rubber plate also is analyzed. The results showed that the composite armour can affect the stability of the jet and made pa...

  10. Numerical studies of large penetrations and closures for containment vessels subjected to loadings beyond the design basis

    International Nuclear Information System (INIS)

    Kulak, R.F.; Hsieh, B.J.; Kennedy, J.M.; Ash, J.E.; McLennan, G.A.

    1984-01-01

    Numerical simulations of the macro-deformations of the sealing surfaces (gasketed junctures) of a PWR steel containment vessel's equipment hatch and a BWR Mk II containment vessel head have been performed. Results for the equipment hatch juncture indicate that the rotations of the hatch cover and penetration sleeve must be accounted for when performing leakage analysis because they can effect the compression of the gasket even though the gasket is in a pressure-seated configuration. Results from a leakage analysis indicated that excessive leakage can occur if the surface roughness is high and/or the compression set is high. Results for the Mk II head show that both the temperature and pressure loadings must be taken into account to obtain realistic responses. The temperature difference between the flanges and bolts has the important net effect of keeping the gasketed juncture closed, that is in metal-to-metal contact. Due to the high accident temperature, the gasket itself was found to achieve 100% compression set and thus could not perform its sealing function within the juncture

  11. Tumor penetrating peptides

    Directory of Open Access Journals (Sweden)

    Tambet eTeesalu

    2013-08-01

    Full Text Available Tumor-homing peptides can be used to deliver drugs into tumors. Phage library screening in live mice has recently identified homing peptides that specifically recognize the endothelium of tumor vessels, extravasate, and penetrate deep into the extravascular tumor tissue. The prototypic peptide of this class, iRGD (CRGDKGPDC, contains the integrin-binding RGD motif. RGD mediates tumor homing through binding to αv integrins, which are selectively expressed on various cells in tumors, including tumor endothelial cells. The tumor-penetrating properties of iRGD are mediated by a second sequence motif, R/KXXR/K. This C-end Rule (or CendR motif is active only when the second basic residue is exposed at the C-terminus of the peptide. Proteolytic processing of iRGD in tumors activates the cryptic CendR motif, which then binds to neuropilin-1 activating an endocytic bulk transport pathway through tumor tissue. Phage screening has also yielded tumor-penetrating peptides that function like iRGD in activating the CendR pathway, but bind to a different primary receptor. Moreover, novel tumor-homing peptides can be constructed from tumor-homing motifs, CendR elements and protease cleavage sites. Pathologies other than tumors can be targeted with tissue-penetrating peptides, and the primary receptor can also be a vascular zip code of a normal tissue. The CendR technology provides a solution to a major problem in tumor therapy, poor penetration of drugs into tumors. The tumor-penetrating peptides are capable of taking a payload deep into tumor tissue in mice, and they also penetrate into human tumors ex vivo. Targeting with these peptides specifically increases the accumulation in tumors of a variety of drugs and contrast agents, such as doxorubicin, antibodies and nanoparticle-based compounds. Remarkably the drug to be targeted does not have to be coupled to the peptide; the bulk transport system activated by the peptide sweeps along any compound that is

  12. Study of Tectonic Tremor in Depth: Triggering Stress Observation and Model of the Triggering Mechanism

    Science.gov (United States)

    Wang, Tien-Huei

    Non-volcanic tremor (NVT) has been discovered in recent years due to advances in seismic instruments and increased density of seismic networks. The NVT is a special kind of seismic signal indicative of the physical conditions and the failure mechanism on the source on the fault where NVT occurs. The detection methods used and the sensitivity of them relies on the density, distance and instrumentation of the station network available. How accurately the tremor is identified in different regions varies greatly among different studies. Therefore, there has not been study that rigorously documents tectonic tremors in different regions under limited methods and data. Meanwhile, many incidences of NVTs are observed during or after small but significant strain change induced by teleseismic, regional or local earthquake. The understanding of the triggering mechanisms critical for tremor remains unclear. In addition, characteristics of the triggering of NVT in different regions are rarely compared because of the short time frame after the discovery of the triggered NVTs. We first explore tectonic tremor based on observations to learn about its triggering, frequency of occurrence, location and spectral characteristics. Then, we numerically model the triggering of instability on the estimated tremor-source, under assumptions fine-tuned according to previous studies (Thomas et al., 2009; Miyazawa et al., 2005; Hill, 2008; Ito, 2009; Rubinstein et al., 2007; Peng and Chao, 2008). The onset of the slip reveals that how and when the external loading triggers tremor. It also holds the information to the background stress conditions under which tremor source starts with. We observe and detect tremor in two regions: Anza and Cholame, along San Jacinto Fault (SJF) and San Andreas Fault (SAF) respectively. These two sections of the faults, relative to general fault zone on which general earthquakes occur, are considered transition zones where slip of slow rates occurs. Slip events

  13. Penetrable silica microspheres for immobilization of bovine serum albumin and their application to the study of the interaction between imatinib mesylate and protein by frontal affinity chromatography.

    Science.gov (United States)

    Ma, Liyun; Li, Jing; Zhao, Juan; Liao, Han; Xu, Li; Shi, Zhi-guo

    2016-01-01

    In the current study, novel featured silica, named penetrable silica, simultaneously containing macropores and mesopores, was immobilized with bovine serum albumin (BSA) via Schiff base method. The obtained BSA-SiO2 was employed as the high-performance liquid chromatographic (HPLC) stationary phase. Firstly, D- and L-tryptophan were used as probes to investigate the chiral separation ability of the BSA-SiO2 stationary phase. An excellent enantioseparation factor was obtained up to 4.3 with acceptable stability within at least 1 month. Next, the BSA-SiO2 stationary phase was applied to study the interaction between imatinib mesylate (IM) and BSA by frontal affinity chromatography. A single type of binding site was found for IM with the immobilized BSA, and the hydrogen-bonding and van der Waals interactions were expected to be contributing interactions based on the thermodynamic studies, and this was a spontaneous process. Compared to the traditional silica for HPLC stationary phase, the proposed penetrable silica microsphere possessed a larger capacity to bond more BSA, minimizing column overloading effects and enhancing enantioseparation ability. In addition, the lower running column back pressure and fast mass transfer were meaningful for the column stability and lifetime. It was a good substrate to immobilize biomolecules for fast chiral resolution and screening drug-protein interactions.

  14. Shallow Depth Study Using Gravity & Magnetics Data in Central Java - Yogyakarta

    Science.gov (United States)

    Fawzy Ismullah M, Muhammad; Altin Massinai, Muhammad; Maria

    2018-03-01

    Gravity and magnetics measurements carried out in Karangsambung - Bayat - Wonosari track, Central Java - Yogyakarta region as much as 34 points for subsurface identification. Modeling and interpretation using both data at 3 sections. Section A lies on Karangsambung area and reach to 1900 m. Section A showed formation of 0.000001 - 0.0014 nT and 2.00 - 2.80 g/cm3 like alluvium, basalt and tuff. Section B lies on Wates - Yogyakarta area and reach to 1700 m. Section B showed formation of (-0.01) - 0.02 nT and 2.40 - 3.00 g/cm3 like andesite intrusive and Merapi volcano sediments. Section C lies on Bayat - Wonosari area and reach to 2000 m. Section C showed formation of 0.00016 - 0.0005 nT and 2.30 - 3.14 g/cm3 like limestone, tuff and diorite intrusive. Based on modeling results from 2D structure inversion method can identify the formation of sediments from volcano activity on Karangsambung - Bayat - Wonosari track, Central Java - Yogyakarta region. The method of this study shows potential application for identify the formation of volcano activity from 2D structure.

  15. In-depth study of single photon time resolution for the Philips digital silicon photomultiplier

    International Nuclear Information System (INIS)

    Liu, Z.; Pizzichemi, M.; Ghezzi, A.; Paganoni, M.; Gundacker, S.; Auffray, E.; Lecoq, P.

    2016-01-01

    The digital silicon photomultiplier (SiPM) has been commercialised by Philips as an innovative technology compared to analog silicon photomultiplier devices. The Philips digital SiPM, has a pair of time to digital converters (TDCs) connected to 12800 single photon avalanche diodes (SPADs). Detailed measurements were performed to understand the low photon time response of the Philips digital SiPM. The single photon time resolution (SPTR) of every single SPAD in a pixel consisting of 3200 SPADs was measured and an average value of 85 ps full width at half maximum (FWHM) was observed. Each SPAD sends the signal to the TDC with different signal propagation time, resulting in a so called trigger network skew. This distribution of the trigger network skew for a pixel (3200 SPADs) has been measured and a variation of 50 ps FWHM was extracted. The SPTR of the whole pixel is the combination of SPAD jitter, trigger network skew, and the SPAD non-uniformity. The SPTR of a complete pixel was 103 ps FWHM at 3.3 V above breakdown voltage. Further, the effect of the crosstalk at a low photon level has been studied, with the two photon time resolution degrading if the events are a combination of detected (true) photons and crosstalk events. Finally, the time response to multiple photons was investigated.

  16. Spatio-temporal dynamics of the penetration resistance of recultivated soils formed after open cast mining

    Directory of Open Access Journals (Sweden)

    A. V. Zhukov

    2016-01-01

    Full Text Available On the basis of studying the spatio-temporal dynamics of soil penetration resistance we proved the existence of the technozem ecomorphs as above horizon soil formations. Research was carried out at a research center for study of recultivation processes in Ordzhonikidze city. Measurement of soils penetration was made in field conditions using an Eijkelkamp penetrometer on a regular grid at depths of up to50 cmwith intervals of5 cm. Calculation of average values and degrees of variation was performed by means of descriptive statistical tools. The extent of soil penetration spatial dependence was assessed and the existence of ecomorphs was proved by means of geostatistical analysis. The degree of associativity of spatial distribution of indicators of a soil body in different years of research was established by means of correlation analysis. The level of variation in space and in time of  technozem penetration generated on loess-like loams, grey-green, red-brown clays, and also pedozems was revealed. The degree of spatial dependence of  technozem penetration within soil layers and also the linear sizes of ecomorphs as above horizon soil structures was established. The time dynamics of  penetration of various recultozems were described. As a result of research into the spatio-temporal dynamics of penetration of technozems, data confirming the hypothesis of the existence of ecomorphs as above horizon morphological soil formations were obtained. An ecomorphic approach to the study of the morphological structure of technozems is proposed. The comparative characteristics of ecomorphs from various types of technozem are presented. The results obtained solve the problem of combining the higher and lowest levels in the hierarchical system of soil organisation as a natural body, which should raise the efficiency of the analysis of relations of morphological elements as a basis for detailed reconstruction of recultivation processes, soil formation, and

  17. Molecules in strong laser fields. In depth study of H{sub 2} molecule

    Energy Technology Data Exchange (ETDEWEB)

    Awasthi, Manohar

    2009-10-29

    above-threshold-ionization peaks is also demonstrated. The CI-TDSE results for H{sub 2} are used for testing the validity of SAE approximation. In strong field physics, there are models based on the SAE approximation. Most popular are the Ammosov-Delone-Krainov (ADK) model, a molecular version of the ADK model called MO-ADK (MO stands for molecular orbital) and the strong field approximation (SFA). The validity of the second method for the solution of TDSE in SAE approximation is investigated by applying it to H{sub 2} molecule where the exact two-electron results were already calculated using CI-TDSE. The SAE method uses density-functional-theory (DFT) for the description of field-free eigenstates and is thus abbreviated as DFT-SAE-TDSE. Since DFT is used for the calculation of field-free states, different functionals were also tested. The validity of MO-ADK model is also investigated. After establishing the DFT-SAE-TDSE method, the first excited state B{sup 1}{sigma}{sub u}{sup +} of H{sub 2} is studied over a large range of laser parameters. The effect of the closely lying excited states on ionization and excitation is studied. After successful testing of DFT-SAE-TDSE method on H{sub 2} molecule, the results for larger molecules like N{sub 2}, O{sub 2} and C{sub 2}H{sub 2} in the DFT-SAE framework are presented. (orig.)

  18. Molecules in strong laser fields. In depth study of H2 molecule

    International Nuclear Information System (INIS)

    Awasthi, Manohar

    2009-01-01

    -threshold-ionization peaks is also demonstrated. The CI-TDSE results for H 2 are used for testing the validity of SAE approximation. In strong field physics, there are models based on the SAE approximation. Most popular are the Ammosov-Delone-Krainov (ADK) model, a molecular version of the ADK model called MO-ADK (MO stands for molecular orbital) and the strong field approximation (SFA). The validity of the second method for the solution of TDSE in SAE approximation is investigated by applying it to H 2 molecule where the exact two-electron results were already calculated using CI-TDSE. The SAE method uses density-functional-theory (DFT) for the description of field-free eigenstates and is thus abbreviated as DFT-SAE-TDSE. Since DFT is used for the calculation of field-free states, different functionals were also tested. The validity of MO-ADK model is also investigated. After establishing the DFT-SAE-TDSE method, the first excited state B 1 Σ u + of H 2 is studied over a large range of laser parameters. The effect of the closely lying excited states on ionization and excitation is studied. After successful testing of DFT-SAE-TDSE method on H 2 molecule, the results for larger molecules like N 2 , O 2 and C 2 H 2 in the DFT-SAE framework are presented. (orig.)

  19. Factors influencing antibiotic prescribing in long-term care facilities: a qualitative in-depth study.

    Science.gov (United States)

    van Buul, Laura W; van der Steen, Jenny T; Doncker, Sarah M M M; Achterberg, Wilco P; Schellevis, François G; Veenhuizen, Ruth B; Hertogh, Cees M P M

    2014-12-16

    Insight into factors that influence antibiotic prescribing is crucial when developing interventions aimed at a more rational use of antibiotics. We examined factors that influence antibiotic prescribing in long-term care facilities, and present a conceptual model that integrates these factors. Semi-structured qualitative interviews were conducted with physicians (n = 13) and nursing staff (n = 13) in five nursing homes and two residential care homes in the central-west region of the Netherlands. An iterative analysis was applied to interviews with physicians to identify and categorize factors that influence antibiotic prescribing, and to integrate these into a conceptual model. This conceptual model was triangulated with the perspectives of nursing staff. The analysis resulted in the identification of six categories of factors that can influence the antibiotic prescribing decision: the clinical situation, advance care plans, utilization of diagnostic resources, physicians' perceived risks, influence of others, and influence of the environment. Each category comprises several factors that may influence the decision to prescribe or not prescribe antibiotics directly (e.g. pressure of patients' family leading to antibiotic prescribing) or indirectly via influence on other factors (e.g. unfamiliarity with patients resulting in a higher physician perceived risk of non-treatment, in turn resulting in a higher tendency to prescribe antibiotics). Our interview study shows that several non-rational factors may affect antibiotic prescribing decision making in long-term care facilities, suggesting opportunities to reduce inappropriate antibiotic use. We developed a conceptual model that integrates the identified categories of influencing factors and shows the relationships between those categories. This model may be used as a practical tool in long-term care facilities to identify local factors potentially leading to inappropriate prescribing, and to subsequently

  20. Coagulopathy and transfusion requirements in war related penetrating traumatic brain injury. A single centre study in a French role 3 medical treatment facility in Afghanistan.

    Science.gov (United States)

    Bordes, J; Joubert, C; Esnault, P; Montcriol, A; Nguyen, C; Meaudre, E; Dulou, R; Dagain, A

    2017-05-01

    Traumatic brain injury associated coagulopathy is frequent, either in isolated traumatic brain injury in civilian practice and in combat traumatic brain injury. In war zone, it is a matter of concern because head and neck are the second most frequent site of wartime casualty burden. Data focusing on transfusion requirements in patients with war related TBI coagulopathy are limited. A descriptive analysis was conducted of 77 penetrating traumatic brain injuries referred to a French role 3 medical treatment facility in Kabul, Afghanistan, deployed on the Kabul International Airport (KaIA), over a 30 months period. On 77 patients, 23 died during the prehospital phase and were not included in the study. Severe traumatic brain injury represented 50% of patients. Explosions were the most common injury mechanism. Extracranial injuries were present in 72% of patients. Traumatic brain injury coagulopathy was diagnosed in 67% of patients at role 3 admission. Red blood cell units (RBCu) were transfused in 39 (72%) patients, French lyophilized plasma (FLYP) in 41 (76%), and fresh whole blood (FWB) in 17 (31%). The results of this study support previous observations of coagulopathy as a frequent complication of traumatic brain injury. The majority of patients with war related penetrating traumatic brain injury presented with extracranial lesions. Most of them required a high level of transfusion capacity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Experimental Study of the Effect of W-weir on Reduction of Scour Depth at 90 Degree Sharp Bend

    Directory of Open Access Journals (Sweden)

    Vida Atashi

    2017-02-01

    Full Text Available Introduction: Flow patterns within the river bend is three dimensional. Occurrence of secondary flow due to centrifugal force and formation of helicoidally vortex in river bend usually causes the outer bank of river erodes whilst the sediment are deposited in inner bend which appears in the form of point bars. To reduce the river bank scour, many techniques have been developed which may be classified as covering technique and modified flow patterns methods. The W-weir is among such structures. In the present paper, by measuring three components of flow velocity with and without presence of W-weir, variation of flow patterns and shear stress distribution in a 90-degree sharp bend have been investigated. The main purpose of this study is to see the installation of different locations of W-weir in the bend on reduction of outer bank scour. In the present paper, by measuring three components of flow velocity with and without presence of W-weir, variation of flow patterns and shear stress distribution in a 90-degree sharp bend have been investigated. The analyses of data showed more uniform flow upstream of the weir and also revealed that the effect of transverse and centrifugal forces are modified in such a way that the secondary flow is diminished. The results showed that for 30, 60 and 90-degree bends maximum erosion depth in the vicinity of the outer bank with Froude number of 0.206 in comparison with 0.137 has increased up to 84, 90 and 118 % respectively. In both Froude numbers, installation of W-Weir in 30 degree has the most reduction in bed in comparison with 60 and 90 degree. Materials and Methods: To reach the goal of this study a physical model of 90 degree sharp bend was constructed in the hydraulic lab of Shahid Chamran university of Ahvaz. The ratio of R(radius/b(flume width was less than 2 which shows a sharp bend. The W-weir was built with 1mm galvanized steel. Flume bed was covered with sediment of D50=1.5mm. The W-weir was

  2. Impacted Mandibular Third Molar, Associated Pathoses, and Their Relation to Angulation and Impaction Depth: A Cone Beam CT Study

    Directory of Open Access Journals (Sweden)

    Movahhedian N

    2018-03-01

    Full Text Available Statement of problem: prophylactic removal of the impacted lower third molar (ILTM is controversial and accompanying pathologic conditions play an important role. Objectives: The aim of the present study is to evaluate the prevalence of commonly found pathoses associated with ILTM in relation to angulation and impaction depth in cone beam computed tomography (CBCT. Materials and Methods: We evaluated CBCT of 500 ILTMs from 235 females (57% and 177 males (43% for the presence of caries on the second and third molars, external root resorption (ERR of the second molar, and follicular spaces (FS >5 mm in diameter in relation to angulation and impaction depth according to Pell and Gregory and Winter’s classifications, respectively. Results: We observed that 55.6% of ILTM had at least one detectible lesion. ERR was the most frequent pathologic condition (31.2%, followed by caries on the second (26% and third (13.4% molars, and FS >5 mm (2.4%. ERR was the only pathology influenced by angulation. There was significantly more ERR in mesioangular ILTMs (40.5%, P5 mm (P=0.035. There were more caries on the second molar (P=0.013 and FS >5 mm (P<0.001 in class III. Conclusions: Prophylactic removal of ILTMs (especially in mesioangular or horizontal impactions could be suggested considering the potential for pathologic changes in ILTMs and the propensity for these teeth to cause ERR in second molars.

  3. A multiproxy study of Holocene water-depth and environmental changes in Lake St Ana, Eastern Carpathian Mountains, Romania

    Science.gov (United States)

    Magyari, E. K.; Buczkó, K.; Braun, M.; Jakab, G.

    2009-04-01

    This study presents the results of a multi-disciplinary investigation carried out on the sediment of a crater lake (Lake Saint Ana, 950 m a.s.l.) from the Eastern Carpathian Mountains. The lake is set in a base-poor volcanic environment with oligotrophic and slightly acidic water. Loss-on-ignition, major and trace element, pollen, plant macrofossil and siliceous algae analyses were used to reconstruct Holocene environmental and water-depth changes. Diatom-based transfer functions were applied to estimate the lake's trophic status and pH, while reconstruction of the water-depth changes was based on the plant macrofossil and diatom records. The lowest Holocene water-depths were found between 9,000 and 7,400 calibrated BP years, when the crater was occupied by Sphagnum-bog and bog-pools. The major trend from 7,400 years BP was a gradual increase, but the basin was still dominated by poor-fen and poor fen-pools. Significant increases in water-depth, and meso/oligotrophic lake conditions were found from 5,350(1), 3,300(2) and 2,700 years BP. Of these, the first two coincided with major terrestrial vegetation changes, namely the establishment of Carpinus betulus on the crater slope (1), and the replacement of the lakeshore Picea abies forest by Fagus sylvatica (2). The chemical record clearly indicated significant soil changes along with the canopy changes (from coniferous to deciduous), that in turn led to increased in-lake productivity and pH. A further increase in water-depth around 2,700 years BP resulted in stable thermal stratification and hypolimnetic anoxia that via P-release further increased in-lake productivity and eventually led to phytoplankton blooms with large populations of Scenedesmus cf. S. brasiliensis. High productivity was depressed by anthropogenic lakeshore forest clearances commencing from ca. 1,000 years BP that led to the re-establishment of Picea abies on the lakeshore and consequent acidification of the lake-water. On the whole, these data

  4. HMO penetration and physicians' earnings.

    Science.gov (United States)

    Hadley, J; Mitchell, J M

    1999-11-01

    The goal of this study is to estimate whether cross-sectional variations in enrollment in health maintenance organizations (HMOs) affected physicians' earnings and hourly income in 1990. Using data from a nationally representative sample of 4,577 younger physicians (penetration is endogenous and used the instrumental variables approach to obtain unbiased estimates. HMO penetration had a negative and statistically significant impact on physicians earnings in 1990. A doubling of the average level of HMO penetration in the market is estimated to reduce annual earnings by 7% to 10.7%, and hourly earnings by approximately 6% to 9%. It appears that HMOs were successful in reducing physicians' annual and per hour earnings in 1990, presumably through a combination of fewer visits and lower payment rates for people covered by HMOs. Although these results cannot be generalized to all physicians, the experience of a younger cohort of physicians may still be a good indicator of the future effects of HMOs because younger physicians may be more susceptible to market forces than older and more established physicians. Moreover, these results may be somewhat conservative because they reflect market behavior in 1990, several years before the rapid growth and more aggressive market behavior of HMOs in recent years.

  5. Injury protection and accident causation parameters for vulnerable road users based on German In-Depth Accident Study GIDAS.

    Science.gov (United States)

    Otte, Dietmar; Jänsch, Michael; Haasper, Carl

    2012-01-01

    Within a study of accident data from GIDAS (German In-Depth Accident Study), vulnerable road users are investigated regarding injury risk in traffic accidents. GIDAS is the largest in-depth accident study in Germany. Due to a well-defined sampling plan, representativeness with respect to the federal statistics is also guaranteed. A hierarchical system ACASS (Accident Causation Analysis with Seven Steps) was developed in GIDAS, describing the human causation factors in a chronological sequence. The accordingly classified causation factors - derived from the systematic of the analysis of human accident causes ("7 steps") - can be used to describe the influence of accident causes on the injury outcome. The bases of the study are accident documentations over ten years from 1999 to 2008 with 8204 vulnerable road users (VRU), of which 3 different groups were selected as pedestrians n=2041, motorcyclists n=2199 and bicyclists n=3964, and analyzed on collisions with cars and trucks as well as vulnerable road users alone. The paper will give a description of the injury pattern and injury mechanisms of accidents. The injury frequencies and severities are pointed out considering different types of VRU and protective measures of helmet and clothes of the human body. The impact points are demonstrated on the car, following to conclusion of protective measures on the vehicle. Existing standards of protection devices as well as interdisciplinary research, including accident and injury statistics, are described. With this paper, a summarization of the existing possibilities on protective measures for pedestrians, bicyclists and motorcyclists is given and discussed by comparison of all three groups of vulnerable road users. Also the relevance of special impact situations and accident causes mainly responsible for severe injuries are pointed out, given the new orientation of research for the avoidance and reduction of accident patterns. 2010 Elsevier Ltd. All rights reserved.

  6. A case study of liquefaction risk analysis based on the thickness and depth of the liquefaction layer using CPT and electric resistivity data in the Hinode area, Itako City, Ibaraki Prefecture, Japan

    Science.gov (United States)

    Jinguuji, Motoharu; Toprak, Selcuk

    2017-12-01

    The Hinode area of Itako City in Ibaraki Prefecture, Japan, suffered some of the most severe liquefaction damage of any areas in the Great Eastern Japan Earthquake in 2011. This liquefaction damage has been investigated by Itako City, as well as by universities and research institutes in Japan. The National Institute of Advanced Industrial Science and Technology (AIST) has carried out numerous investigations along the Tone River, and in particular, intensive surveys were done in the Hinode area. We have conducted a risk analysis based on the thickness and depth of the liquefaction layer measured using cone penetration testing (CPT) data and electric resistivity data obtained in the Hinode area. The distribution of the risk estimated from CPT at 143 points, and that obtained from analysis of the resistivity survey data, agreed with the distribution of actual damage. We also carried out conventional risk analyses method using the liquefaction resistance factor (FL) and liquefaction potential index (PL) methods with CPT data. The results show high PL values over the entire area, but their distribution did not agree well with actual damage in some parts of the study area. Because the analysis of the thickness and depth of the liquefaction layer, using geophysical prospecting methods, can cover a widespread area, this method will be very useful in investigating liquefaction risk, especially for gas and water pipelines.

  7. Penetration and delivery characteristics of repetitive microjet injection into the skin.

    Science.gov (United States)

    Römgens, Anne M; Rem-Bronneberg, Debbie; Kassies, Roel; Hijlkema, Markus; Bader, Dan L; Oomens, Cees W J; van Bruggen, Michel P B

    2016-07-28

    Drugs can be delivered transdermally using jet injectors, which can be an advantageous route compared to oral administration. However, these devices inject large volumes deep into the skin or tissues underneath the skin often causing bruising and pain. This may be prevented by injecting smaller volumes at lower depth in a repetitive way using a microjet injection device. Such a device could be used to apply drugs in a controllable and sustainable manner. However, the efficacy of microjet injection has been rarely examined. In this study, the penetration and delivery capacity was examined of a repetitive microjet injection device. Various experiments were performed on epidermal and full-thickness ex vivo human as well as ex vivo porcine skin samples. Results revealed that microjets with a velocity exceeding 90m/s penetrated an epidermal skin sample with a delivery efficiency of approximately 96%. In full-thickness human skin, the delivery efficiency drastically decreased to a value of approximately 12%. Experiments on full-thickness skin revealed that the microjets penetrated to a depth corresponding to the transition between the papillary and reticular dermis. This depth did not further increase with increasing number of microjets. In vivo studies on rats indicated that intact insulin was absorbed into the systemic circulation. Hence, the microjet injection device was able to deliver medication into the skin, although the drug delivery efficiency should be increased. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. How has Mobile Phone Penetration Stimulated Financial Development in Africa?

    OpenAIRE

    Simplice A, Asongu

    2012-01-01

    In the first macroeconomic empirical assessment of the relationship between mobile phones and finance, this paper examines the correlations between mobile phone penetration and financial development using two conflicting definitions of the financial system in the financial development literature. With the traditional IFS (2008) definition, mobile phone penetration has a negative correlation with traditional financial intermediary dynamics of depth, activity and size. However, when a previous...

  9. Accuracy of Endoscopy in Predicting the Depth of Mucosal Injury Following Caustic Ingestion; a Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Athena Alipour-Faz

    2017-01-01

    Full Text Available Introduction: Esophagogastroduodenoscopy (EGD is currently considered as the primary method of determining the degree of mucosal injury following caustic ingestion. The present study aimed to evaluate the screening performance characteristics of EGD in predicting the depth of gastrointestinal mucosal injuries following caustic ingestion.Methods: Adult patients who were referred to emergency department due to ingestion of corrosive materials, over a 7-year period, were enrolled to this diagnostic accuracy study. Sensitivity, specificity, positive and negative predictive values as well as negative and positive likelihood ratios of EGD in predicting the depth of mucosal injury was calculated using pathologic findings as the gold standard.Results: 54 cases with the mean age of 35 ± 11.2 years were enrolled (59.25% male. Primary endoscopic results defined 28 (51.85% cases as second grade and 26 (48.14% as third grade of mucosal injury. On the other hand, pathologic findings reported 21 (38.88% patients as first grade, 14 (25.92% as second, and 19 patients (35.18% as third grade. Sensitivity and specificity of endoscopy for determining grade II tissue injury were 50.00 (23.04-76.96 and 47.50 (31.51-63.87, respectively. These measures were 100.00 (82.35-100 and 80.00 (63.06-91.56, respectively for grade III. Accuracy of EGD was 87.03% for grade III and 48.14% for grade II.Conclusion: Based on the findings of the present study, endoscopic grading of caustic related mucosal injury based on the Zargar’s classification has good accuracy in predicting grade III (87% and fail accuracy in grade II injuries (48%. It seems that we should be cautious in planning treatment for these patients solely based on endoscopic results. 

  10. Antibody tumor penetration

    Science.gov (United States)

    Thurber, Greg M.; Schmidt, Michael M.; Wittrup, K. Dane

    2009-01-01

    Antibodies have proven to be effective agents in cancer imaging and therapy. One of the major challenges still facing the field is the heterogeneous distribution of these agents in tumors when administered systemically. Large regions of untargeted cells can therefore escape therapy and potentially select for more resistant cells. We present here a summary of theoretical and experimental approaches to analyze and improve antibody penetration in tumor tissue. PMID:18541331

  11. Python penetration testing essentials

    CERN Document Server

    Mohit

    2015-01-01

    If you are a Python programmer or a security researcher who has basic knowledge of Python programming and want to learn about penetration testing with the help of Python, this book is ideal for you. Even if you are new to the field of ethical hacking, this book can help you find the vulnerabilities in your system so that you are ready to tackle any kind of attack or intrusion.

  12. Modeling of Oblique Penetration into Geologic Targets Using Cavity Expansion Penetrator Loading with Target free-Surface Effects

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joe; Longcope, Donald B.; Tabbara, Mazen R.

    1999-06-01

    A procedure has been developed to represent the loading on a penetrator and its motion during oblique penetration into geologic media. The penetrator is modeled with the explicit dynamics, finite element computer program PRONTO 3D and the coupled pressure on the penetrator is given in a new loading option based on a separate cavity expansion (CE) solution that accounts for the pressure reduction from a nearby target free surface. The free-surface influence distance is selected in a predictive manner by considering the pressure to expand a spherical cavity in a finite radius sphere of the target material. The CE/PRONTO 3D procedure allows a detailed description of the penetrator for predicting shock environments or structural failure during the entire penetra- tion event and is sufficiently rapid to be used in design optimization. It has been evaluated by comparing its results with data from two field tests of a full-scale penetrator into frozen soil at an impact angles of 49.6 and 52.5 degrees from the horizontal. The measured penetrator rotations were 24 and 22 degrees, respectively. In the simulation, the rotation was 21 degrees and predom- inately resulted from the pressure reduction of the free surface. Good agreement was also found for the penetration depth and axial and lateral acceleration at two locations in the penetrator.

  13. Ground-Penetrating Radar Study of Fort Morgan Peninsula Holocene Beach Ridges as Sea-level Indicators

    Science.gov (United States)

    Philbin, A.; Frederick, B.; Blum, M. D.; Tsoflias, G. P.

    2017-12-01

    Holocene sea-level change along the northern Gulf of Mexico (GoM) coast is controversial. One view interprets basal peats from the Mississippi Delta to indicate continual sea-level (SL) rise for the GoM as a whole. An alternate view proposes that data from the subsiding delta is primarily a subsidence signal, and that sandy non-deltaic shorelines indicate that regional SL reached present elevations by the middle Holocene, with minor oscillations since then. In fact, new regional long-term subsidence records from biostratigraphic indicators display significant subsidence in deltaic areas where basal-peat data were collected, and negligible rates along the GoM shoreline to the east. However, the use of sandy progradational shorelines, commonly known as "beach ridge systems", has been criticized for a lack of precise sea-level indicators, and therefore discounted. This research focuses on developing Holocene progradational sandy shorelines along the Alabama coast in the eastern GoM as SL indicators. Sandy shorelines in this area are ideal to examine SL change because they are well preserved, sufficiently distant from the subsiding delta, well mapped, and ages are known from previous work. Two-dimensional ground-penetrating radar imaging of well-dated beach-ridge successions is used here to examine and identify changes through time in the elevation of the shoreface clinoform topset-foreset break, which represents the transition between flat-lying foreshore and seaward-dipping shoreface facies, and forms in the intertidal zone. Beach-ridge successions with optical luminescence ages of ca. 5500-4800 yrs BP display topset-foreset breaks at current mean sea-level elevation, whereas beach-ridge successions from ca. 3500-2400 yrs BP display topset-foreset breaks that are 1 m above present mean SL and the elevation of modern topset-foreset breaks. These data support the view that current sea-level was reached by the middle Holocene, and was higher than present for at least

  14. Partial liquid-penetration inside a deep trench by film flowing over it

    Science.gov (United States)

    Nguyen, Phuc-Khanh; Dimakopoulos, Yiannis; Tsamopoulos, John

    2014-11-01

    Liquid film flow along substrates featuring a deep trench may not wet the trench floor, but create a second gas-liquid interface inside the trench. The liquid penetration inside the trench depends on the location and shape of this inner interface. The penetration increases by decreasing the two three-phase contact lines between the inner interface and the two side-walls or the flow rate and depends on the liquid properties. This partial-penetration is studied by employing the Galerkin / finite element method to solve the two-dimensional steady-state Navier-Stokes equations in a physical domain that is adaptively remeshed. Multiple branches of steady solutions connected via turning points are revealed by pseudo arc-length continuation. Flow hysteresis may occur in a certain range of liquid penetration depth, when the interaction of the two interfaces changes qualitatively. This induces an abrupt jump of penetration distance and deformation amplitude of the outer interface. Work supported by the General Secretariat of Research & Technology of Greece through the program ``Excellence'' (Grant No. 1918) in the framework ``Education and Lifelong Learning'' co-funded by the ESF.

  15. Failure of preventive measures against radon penetration from the ground in a new-built family house - a case study

    International Nuclear Information System (INIS)

    Neznal, M.; Neznal, M.; Jiranek, M.; Fronka, A.

    2006-01-01

    A system of preventive protection of houses against radon penetration from the ground [1] has been in operation for more than 15 years in the Czech Republic. The determination of a so-called radon index of the building site represents the first step. The assessment is based on measurements of soil gas radon concentration and on the determination of soil permeability. During the years, the method was modified several times, especially the recommendation dealing with the classification of soil permeability, but the base remains stable: The soil characteristics are measured in-situ and protective measures are designed with respect to the measured properties of the soil and to the dwelling design. The site-specific, individual approach should enable to propose an optimal preventive strategy corresponding to local conditions. If the radon index is other than low (i.e. medium, or high), the building must be protected against radon in accordance with the Czech Atomic Law. Protective measures should be designed and installed according to the Czech National Standard [2]. Basic principles of the protection can be summarized in the following way: If the radon index of a building site is low, no special provisions are required. Normal damp-proofing that is designed in accordance with hydro-geological conditions provides sufficient building protection. Nevertheless, the insulation has to be installed over the whole ground area of the building. It is also recommended that the corridor with stairs leading from the underground floor to the upper floors should be separated by the door. In case of medium radon index of a building site, each high-quality and long life damp-proofing, with the measured radon diffusion coefficient, may be considered as radon-proof insulation in compliance with C.S.N. 73 06 01. A required insulation thickness is calculated using the known value of radon diffusion coefficient. The insulation must be laid down continuously on the whole area of the

  16. Measurements of intraocular pressure by Goldmann tonometry, Tonopen XL, and the transpalpebral tonometer, TGDc-01, after penetrating keratoplasty: a comparativye study.

    Science.gov (United States)

    Shemesh, Gabi; Waisbourd, Michael; Varssano, David; Michaeli, Adi; Lazar, Moshe; Kurtz, Shimon

    2009-08-01

    The aim of this study was to compare intraocular pressure (IOP) measurements obtained by Goldmann tonometry (GT), the Tonopen XL, and a new transpalpebral tonometer, TGDc-01, in eyes that had undergone penetrating keratoplasty (PKP). IOP was measured in post-PKP eyes by means of GT, Tonopen XL, and TGDc-01. Central corneal thickness measurements were also obtained for all eyes. Forty-five eyes of 43 patients were enrolled in the study. The mean IOP difference (+/-SD) was -0.42 +/- 5.83 mm Hg between GT and Tonopen and 3.20 +/- 7.55 mm Hg between GT and TGDc-01. The correlation coefficient was 0.84 between GT and Tonopen XL (P tonometer is simply inaccurate or whether avoiding contact with the corneal graft by measuring IOP through the eyelid enables it to provide more accurate IOP readings than those obtained by transcorneal techniques.

  17. Penetration of Streptococcus sobrinus and Streptococcus sanguinis into dental enamel.

    Science.gov (United States)

    Kneist, Susanne; Nietzsche, Sandor; Küpper, Harald; Raser, Gerhard; Willershausen, Brita; Callaway, Angelika

    2015-10-01

    The aim of this pilot study was to assess the difference in virulence of acidogenic and aciduric oral streptococci in an in vitro caries model using their penetration depths into dental enamel. 30 caries-free extracted molars from 11- to 16-year-olds were cleaned ultrasonically for 1 min with de-ionized water and, after air-drying, embedded in epoxy resin. After 8-h of setting at room temperature, the specimens were ground on the buccal side with SiC-paper 1200 (particle size 13-16 μm). Enamel was removed in circular areas sized 3 mm in diameter; the mean depth of removed enamel was 230 ± 60 μm. 15 specimens each were incubated anaerobically under standardized conditions with 24 h-cultures of Streptococcus sanguinis 9S or Streptococcus sobrinus OMZ 176 in Balmelli broth at 37 ± 2 °C; the pH-values of the broths were measured at the beginning and end of each incubation cycle. After 2, 4, 6, 8, and 10 weeks 3 teeth each were fixed in 2.5% glutaraldehyde in cacodylate buffer for 24 h, washed 3× and dehydrated 30-60min by sequential washes through a series of 30-100% graded ethanol. The teeth were cut in half longitudinally; afterward, two slits were made to obtain fracture surfaces in the infected area. After critical-point-drying the fragments were gold-sputtered and viewed in a scanning electron microscope at magnifications of ×20-20,000. After 10 weeks of incubation, penetration of S. sanguinis of 11.13 ± 24.04 μm below the break edges into the enamel was observed. The invasion of S. sobrinus reached depths of 87.53 ± 76.34 μm. The difference was statistically significant (paired t test: p = 0.033). The experimental penetration depths emphasize the importance of S. sanguinis versus S. sobrinus in the context of the extended ecological plaque hypothesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. The penetration of aerosols through fine orifices

    International Nuclear Information System (INIS)

    Marshall, I.A.; Latham, L.J.; Ball, M.H.E.; Mitchell, J.P.

    1991-07-01

    A novel experimental technique has been extended to study the migration of gas-borne glass microspheres in the size range from about 1 to 15 μm volume equivalent diameter through orifices with bores and thicknesses in the range from 2 to 100 μm and 12.7 to 509 μm respectively. The penetration of these particles was significant with all orifices greater than 10 μm bore at a constant driving pressure of 100 kPa. However, few particles penetrated the 5 μm bore orifice, while virtually no particles penetrated the 2 μm bore orifice. Particle size distributions determined after penetration through the orifices were very similar to that of the upstream aerosol except when significant attenuation occurred. (author)

  19. The penetration of aerosols through fine capillaries

    International Nuclear Information System (INIS)

    Mitchell, J.P.; Edwards, R.T.; Ball, M.H.E.

    1989-10-01

    A novel experimental technique has been developed to study the penetration of aerosol particles ranging from about 1 to 15 μm aerodynamic diameter through capillaries varying from 20 to 80 μm bore and from 10 to 50 mm in length. When the driving pressure was 100 kPa, the penetration of the airborne particles was considerably smaller than expected from a simple comparison of particle diameter with the bore of the capillary. Particle size distributions determined after penetration through the capillaries were in almost all cases similar to the particle size distribution of the aerosol at the capillary entrance. This lack of size-selectivity can be explained in terms of the capillary behaving as a conventional suction-based sampler from a near still (calm) air environment. The resulting particle penetration data are important in assessing the potential for the leakage of aerosols through seals in containers used to transport radioactive materials. (author)

  20. EMD-RBFNN Coupling Prediction Model of Complex Regional Groundwater Depth Series: A Case Study of the Jiansanjiang Administration of Heilongjiang Land Reclamation in China

    Directory of Open Access Journals (Sweden)

    Qiang Fu

    2016-08-01

    Full Text Available The accurate and reliable prediction of groundwater depth is the basis of the sustainable utilization of regional groundwater resources. However, the complexity of the prediction has been ignored in previous studies of regional groundwater depth system analysis and prediction, making it difficult to realize the scientific management of groundwater resources. To address this defect, taking complexity diagnosis as the research foundation, this paper proposes a new coupling forecast strategy for evaluating groundwater depth based on empirical mode decomposition (EMD and a radial basis function neural network (RBFNN. The data used for complexity analysis and modelling are the monthly groundwater depth series monitoring data from 15 long-term monitoring wells from 1997 to 2007, which were collected from the Jiansanjiang Administration of Heilongjiang Agricultural Reclamation in China. The calculation results of the comprehensive complexity index for each groundwater depth series obtained are based on wavelet theory, fractal theory, and the approximate entropy method. The monthly groundwater depth sequence of District 8 of Farm Nongjiang, which has the highest complexity among the five farms in the Jiansanjiang Administration midland, was chosen as the modelling sample series. The groundwater depth series of District 8 of Farm Nongjiang was separated into five intrinsic mode function (IMF sequences and a remainder sequence by applying the EMD method, which revealed that local groundwater depth has a significant one-year periodic character and an increasing trend. The RBFNN was then used to forecast and stack each EMD separation sequence. The results suggest that the future groundwater depth will remain at approximately 10 m if the past pattern of water use continues, exceeding the ideal depth of groundwater. Thus, local departments should take appropriate countermeasures to conserve groundwater resources effectively.

  1. The practice of commissioning healthcare from a private provider: learning from an in-depth case study.

    Science.gov (United States)

    Chambers, Naomi; Sheaff, Rod; Mahon, Ann; Byng, Richard; Mannion, Russell; Charles, Nigel; Exworthy, Mark; Llewellyn, Sue

    2013-01-01

    The direction of health service policy in England is for more diversification in the design, commissioning and provision of health care services. The case study which is the subject of this paper was selected specifically because of the partnering with a private sector organisation to manage whole system redesign of primary care and to support the commissioning of services for people with long term conditions at risk of unplanned hospital admissions and associated service provision activities. The case study forms part of a larger Department of Health funded project on the practice of commissioning which aims to find the best means of achieving a balance between monitoring and control on the one hand, and flexibility and innovation on the other, and to find out what modes of commissioning are most effective in different circumstances and for different services. A single case study method was adopted to explore multiple perspectives of the complexities and uniqueness of a public-private partnership referred to as the "Livewell project". 10 single depth interviews were carried out with key informants across the GP practices, the PCT and the private provider involved in the initiative. The main themes arising from single depth interviews with the case study participants include a particular understanding about the concept of commissioning in the context of primary care, ambitions for primary care redesign, the importance of key roles and strong relationships, issues around the adoption and spread of innovation, and the impact of the current changes to commissioning arrangements. The findings identified a close and high trust relationship between GPs (the commissioners) and the private commissioning support and provider firm. The antecedents to the contract for the project being signed indicated the importance of leveraging external contacts and influence (resource dependency theory). The study has surfaced issues around innovation adoption in the healthcare context

  2. Eddy current testing with high penetration

    International Nuclear Information System (INIS)

    Becker, R.; Kroening, M.

    1999-01-01

    The low-frequency eddy current testing method is used when penetration into very deep layers is required. The achievable penetration depth is determined among other parameters by the lowest testing frequency that can be realised together with the eddy current sensor. When using inductive sensors, the measuring effect declines proportional to the lowering frequency (induction effect). Further reduction of testing frequency requires other types of sensors, as e.g. the GMR (Giant Magnetic Resistance), which achieves a constant measuring sensitivity down to the steady field. The multi-frequency eddy current testing method MFEC 3 of IZFP described here can be operated using three different scanning frequencies at a time. Two variants of eddy current probes are used in this case. Both have an inductive winding at their emitters, of the type of a measuring probe. The receiver end is either also an inductive winding, or a magnetic field-responsive resistance (GMR). (orig./CB) [de

  3. Slab Penetration vs. Slab Stagnation: Mantle Reflectors as an Indicator

    Science.gov (United States)

    Okeler, A.; Gu, Y. J.; Schultz, R.; Contenti, S. M.

    2011-12-01

    Subducting oceanic lithosphere along convergent margins may stagnate near the base of the upper mantle or penetrate into the lower mantle. These dynamic processes cause extensive thermal and compositional variations, which can be observed in terms of impedance contrast (reflectivity) and topography of mantle transition zone (MTZ) discontinuities, i.e., 410- and 660-km discontinuities. In this study, we utilize ~ 15000 surface-reflected shear waves (SS) and their precursory arrivals (S410S and S660S) to analyze subduction related deformations on mantle reflectivity structure. We apply pre-stack, time-to-depth migration technique to SS precursors, and move weak underside reflections using PREM-predicted travel-time curves. Common Mid-point gathers are formed to investigate structure under the western Pacific, south America, and Mediterranean convergent boundaries. In general, mantle reflectivity structures are consistent with previous seismic tomography models. In regions of slab penetration (e.g., southern Kurile arc, Aegean Sea), our results show 1) a substantial decrease in S660S amplitude, and 2) strong lower mantle reflector(s) at ~ 900 km depth. These reflective structures are supported by zones of high P and S velocities extending into the lower mantle. Our 1-D synthetic simulations suggest that the decreasing S660S amplitudes are, at least partially, associated with shear wave defocusing due to changes in reflector depth (by ±20 km) within averaging bin. Assuming a ~500 km wide averaging area, a dipping reflector with 6-8 % slope can reduce the amplitude of a SS precursor by ~50%. On the other hand, broad depressions with strong impedance contrast at the base of the MTZ characterize the regions of slab stagnation, such as beneath the Tyrrhenian Sea and northeastern China. For the latter region, substantial topography on the 660-km discontinuity west of the Wadati-Benioff zone suggests that the stagnant part of the Pacific plate across Honshu arc is not

  4. Penetrating ureteral trauma

    Directory of Open Access Journals (Sweden)

    Gustavo P. Fraga

    2007-04-01

    Full Text Available OBJECTIVE: The purpose of this series is to report our experience in managing ureteral trauma, focusing on the importance of early diagnosis, correct treatment, and the impact of associated injuries on the management and morbid-mortality. MATERIALS AND METHODS: From January 1994 to December 2002, 1487 laparotomies for abdominal trauma were performed and 20 patients with ureteral lesions were identified, all of them secondary to penetrating injury. Medical charts were analyzed as well as information about trauma mechanisms, diagnostic routine, treatment and outcome. RESULTS: All patients were men. Mean age was 27 years. The mechanisms of injury were gunshot wounds in 18 cases (90% and stab wounds in two (10%. All penetrating abdominal injuries had primary indication of laparotomy, and neither excretory urography nor computed tomography were used in any case before surgery. The diagnosis of ureteric injury was made intra-operatively in 17 cases (85%. Two ureteral injuries (10% were initially missed. All patients had associated injuries. The treatment was dictated by the location, extension and time necessary to identify the injury. The overall incidence of complications was 55%. The presence of shock on admission, delayed diagnosis, Abdominal Trauma Index > 25, Injury Severity Score > 25 and colon injuries were associated to a high complication rate, however, there was no statistically significant difference. There were no mortalities in this group. CONCLUSIONS: A high index of suspicion is required for diagnosis of ureteral injuries. A thorough exploration of all retroperitoneal hematoma after penetrating trauma should be an accurate method of diagnosis; even though it failed in 10% of our cases.

  5. Market penetration of ethanol

    International Nuclear Information System (INIS)

    Szulczyk, Kenneth R.; McCarl, Bruce A.; Cornforth, Gerald

    2010-01-01

    This research examines in detail the technology and economics of substituting ethanol for gasoline. This endeavor examines three issues. First, the benefits of ethanol/gasoline blends are examined, and then the technical problems of large-scale implementation of ethanol. Second, ethanol production possibilities are examined in detail from a variety of feedstocks and technologies. The feedstocks are the starch/sugar crops and crop residues, while the technologies are corn wet mill, dry grind, and lignocellulosic fermentation. Examining in detail the production possibilities allows the researchers to identity the extent of technological change, production costs, byproducts, and GHG emissions. Finally, a U.S. agricultural model, FASOMGHG, is updated which predicts the market penetration of ethanol given technological progress, variety of technologies and feedstocks, market interactions, energy prices, and GHG prices. FASOMGHG has several interesting results. First, gasoline prices have a small expansionary impact on the U.S. ethanol industry. Both agricultural producers' income and cost both increase with higher energy prices. If wholesale gasoline is $4 per gallon, the predicted ethanol market penetration attains 53% of U.S. gasoline consumption in 2030. Second, the corn wet mill remains an important industry for ethanol production, because this industry also produces corn oil, which could be converted to biodiesel. Third, GHG prices expand the ethanol industry. However, the GHG price expands the corn wet mill, but has an ambiguous impact on lignocellulosic ethanol. Feedstocks for lignocellulosic fermentation can also be burned with coal to generate electricity. Both industries are quite GHG efficient. Finally, U.S. government subsidies on biofuels have an expansionary impact on ethanol production, but may only increase market penetration by an additional 1% in 2030, which is approximately 6 billion gallons. (author)

  6. Deep penetration calculations

    International Nuclear Information System (INIS)

    Thompson, W.L.; Deutsch, O.L.; Booth, T.E.

    1980-04-01

    Several Monte Carlo techniques are compared in the transport of neutrons of different source energies through two different deep-penetration problems each with two parts. The first problem involves transmission through a 200-cm concrete slab. The second problem is a 90 0 bent pipe jacketed by concrete. In one case the pipe is void, and in the other it is filled with liquid sodium. Calculations are made with two different Los Alamos Monte Carlo codes: the continuous-energy code MCNP and the multigroup code MCMG

  7. Northeast Cooperative Research Study Fleet (SF) Program Combined GPS, Temperature/Depth, and Effort Fishery Dependent Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature, depth(TD), GPS and haul by haul effort and catch data are collected during normal fishing activity of commercial fishing vessels participating in the...

  8. Penetrating Osseous Spicules Causing High-Flow Ventral CSF Leaks in the Setting of Relatively Low BMI : A Preliminary Study.

    Science.gov (United States)

    Rosebrock, Richard E; Diehn, Felix E; Luetmer, Patrick H; Wald, John T; Lane, John I; Morris, Jonathan M; Lehman, Vance T; Carr, Carrie M; Mokri, Bahram; Thielen, Kent R

    2017-05-16

    We have anecdotally observed patients with high-flow ventral cerebrospinal fluid (CSF) leaks resulting from penetrating osseous spicules or calcified discs to be relatively thin. The purpose of this study was to explore the validity of this observation and determine if a potential association exists between low body mass index (BMI) and high-flow spinal ventral CSF leaks resulting from such dura-penetrating lesions. Sixteen consecutive patients with precisely localized high-flow ventral spinal CSF leaks on dynamic myelography were identified. The cause of the CSF leak was determined. The BMI on the date nearest to and within 2 weeks of myelography was recorded. Utilizing exact sign test, the body mass index was compared to the average BMI from the National Health and Nutrition Examination Survey (Centers for Disease Control), matched to sex and age-range. The cohort consisted of 10 males (63%) and 6 females with a mean age of 54 years (range 37-72 years). In all patients, a spiculated osteophyte/calcified disc was identified at the site of the leak. Fourteen patients (88%) had a BMI below the matched national average, while only two patients (13%) had values above the national average (p = 0.004). Patients with high-flow ventral CSF leaks resulting from spiculated osteophyte or calcified disc as identified by dynamic myelography are more likely to have a BMI below the U.S. national average, matched for gender and age-range. This exploratory analysis requires confirmation as well as further characterization of potential pathophysiologic mechanisms and impact on radiographic and clinical assessments.

  9. Defect and dopant depth profiles in boron-implanted silicon studied with channeling and nuclear reaction analysis

    NARCIS (Netherlands)

    Vos, M.; Boerma, D.O.; Smulders, P.J.M.; Oosterhoff, S.

    1986-01-01

    Single crystals of silicon were implanted at RT with 1 MeV boron ions to a dose of 1 × 1015 ions/cm2. The depth profile of the boron was measured using the 2060-keV resonance of the 11B(α, n)14N nuclear reaction. The distribution of the lattice disorder as a function of depth was determined from

  10. Influence of depth, time and human activity on detection rate of acoustic tags: a case study on two fish farms.

    Science.gov (United States)

    Otterå, H; Skilbrei, O T

    2016-03-01

    The detection rates of stationary acoustic transmitters deployed at three depths on two Atlantic salmon Salmo salar cage farms for c. 2 months were investigated. Deployment depth, time of day, day of the year and specific incidences at the farm substantially affected the rate of signal detection by the receiver. © 2016 The Authors. Journal of Fish Biology published by John Wiley & Sons Ltd on behalf of The Fisheries Society of the British Isles.

  11. Depth Dose Distribution Study within a Phantom Torso after Irradiation with a Simulated Solar Particle Event at NSRL

    Science.gov (United States)

    Berger, Thomas; Matthiae, Daniel; Koerner, Christine; George, Kerry; Rhone, Jordan; Cucinotta, Francis; Reitz, Guenther

    2010-01-01

    The adequate knowledge of the radiation environment and the doses incurred during a space mission is essential for estimating an astronaut's health risk. The space radiation environment is complex and variable, and exposures inside the spacecraft and the astronaut's body are compounded by the interactions of the primary particles with the atoms of the structural materials and with the body itself Astronauts' radiation exposures are measured by means of personal dosimetry, but there remains substantial uncertainty associated with the computational extrapolation of skin dose to organ dose, which can lead to over- or underestimation of the health risk. Comparisons of models to data showed that the astronaut's Effective dose (E) can be predicted to within about a +10% accuracy using space radiation transport models for galactic cosmic rays (GCR) and trapped radiation behind shielding. However for solar particle event (SPE) with steep energy spectra and for extra-vehicular activities on the surface of the moon where only tissue shielding is present, transport models predict that there are large differences in model assumptions in projecting organ doses. Therefore experimental verification of SPE induced organ doses may be crucial for the design of lunar missions. In the research experiment "Depth dose distribution study within a phantom torso" at the NASA Space Radiation Laboratory (NSRL) at BNL, Brookhaven, USA the large 1972 SPE spectrum was simulated using seven different proton energies from 50 up to 450 MeV. A phantom torso constructed of natural bones and realistic distributions of human tissue equivalent materials, which is comparable to the torso of the MATROSHKA phantom currently on the ISS, was equipped with a comprehensive set of thermoluminescence detectors and human cells. The detectors are applied to assess the depth dose distribution and radiation transport codes (e.g. GEANT4) are used to assess the radiation field and interactions of the radiation field

  12. A pilot study exploring the effects of musical genres on the depth of general anaesthesia assessed by haemodynamic responses.

    Science.gov (United States)

    Mira, Filipa; Costa, Alexandra; Mendes, Eva; Azevedo, Pedro; Carreira, L Miguel

    2016-08-01

    This pilot study aimed to investigate whether and how music and musical genres may influence the depth of anaesthesia, as measured using changes in arterial blood pressure (ABP), including systolic blood pressure (SBP), and heart rate (HR) across three different surgical time points. This work focused on a sample of 12 female cats (Felis catus) that were subjected to an elective ovariohysterectomy (OVH), and three different surgical time points were considered (T1, coeliotomy; T2, ligature placement and transection of the ovarian pedicle; and T3, ligature placement and transection of the uterine body). All of the cats were subjected to stimulation with 2 min segments of three music tracks from different genres (pop [PM], classical [CM] and heavy metal [HM]). At the same time, ABP and HR measurements were obtained using a multi-parametric monitor. For statistical analysis, P values music exposure induced statistically significant changes in the parameters under study; the same finding was observed for the genre of music. The majority of cats experienced the same variation pattern, with lower values when exposed to CM, intermediate values when exposed to PM and higher values when exposed to HM. Our results indicate that the development of sensory processing of acoustic stimuli is maintained by cats under general anaesthesia and reveal the influence of music on the autonomous nervous system, as measured using HR and SBP. © ISFM and AAFP 2015.

  13. An in-depth study of patent medicine sellers' perspectives on malaria in a rural Nigerian community

    Directory of Open Access Journals (Sweden)

    Okafor Henrietta U

    2006-11-01

    Full Text Available Abstract Background Malaria remains a major cause of mortality among under five children in Nigeria. Most of the early treatments for fever and malaria occur through self-medication with antimalarial drugs bought from medicine sellers. These have led to increasing calls for interventions to improve treatment obtained in these outlets. However, information about the current practices of these medicine sellers is needed before such interventions. This study aims to determine the medicine sellers' perspectives on malaria and the determinants that underlie their dispensing patterns of antimalarial drugs. Methods The study was conducted in Ugwugo-Nike, a rural community in south-east Nigeria. It involved in-depth interviews with 13 patent medicine sellers. Results A majority of the medicine sellers were not trained health professionals and malaria is recognized as a major health problem by them. There is poor knowledge and poor dispensing behaviour in relation to childhood malaria episodes. Although referral of severe malaria is common, there are those who will not refer. Verbal advice is rarely given to the care-givers. Conclusion More action research and interventions to improve prescription and referral practices and giving verbal advice to care-givers is recommended. Ways to integrate the drug sellers in the health system are also recommended.

  14. The Differences in Source Dynamics Between Intermediate-Depth and Deep EARTHQUAKES:A Comparative Study Between the 2014 Rat Islands Intermediate-Depth Earthquake and the 2015 Bonin Islands Deep Earthquake

    Science.gov (United States)

    Twardzik, C.; Ji, C.

    2015-12-01

    It has been proposed that the mechanisms for intermediate-depth and deep earthquakes might be different. While previous extensive seismological studies suggested that such potential differences do not significantly affect the scaling relationships of earthquake parameters, there has been only a few investigations regarding their dynamic characteristics, especially for fracture energy. In this work, the 2014 Mw7.9 Rat Islands intermediate-depth (105 km) earthquake and the 2015 Mw7.8 Bonin Islands deep (680 km) earthquake are studied from two different perspectives. First, their kinematic rupture models are constrained using teleseismic body waves. Our analysis reveals that the Rat Islands earthquake breaks the entire cold core of the subducting slab defined as the depth of the 650oC isotherm. The inverted stress drop is 4 MPa, compatible to that of intra-plate earthquakes at shallow depths. On the other hand, the kinematic rupture model of the Bonin Islands earthquake, which occurred in a region lacking of seismicity for the past forty years, according to the GCMT catalog, exhibits an energetic rupture within a 35 km by 30 km slip patch and a high stress drop of 24 MPa. It is of interest to note that although complex rupture patterns are allowed to match the observations, the inverted slip distributions of these two earthquakes are simple enough to be approximated as the summation of a few circular/elliptical slip patches. Thus, we investigate subsequently their dynamic rupture models. We use a simple modelling approach in which we assume that the dynamic rupture propagation obeys a slip-weakening friction law, and we describe the distribution of stress and friction on the fault as a set of elliptical patches. We will constrain the three dynamic parameters that are yield stress, background stress prior to the rupture and slip weakening distance, as well as the shape of the elliptical patches directly from teleseismic body waves observations. The study would help us

  15. Effect of unstable layer depth on the pore pressure distribution, case study of the Slano Blato landslide (Slovenia)

    Science.gov (United States)

    Askarinejad, Amin; Secchi, Bandar; Macek, Matej; Petkovsek, Ana; Springman, Sarah

    2013-04-01

    The Slano Blato landslide is one of the largest landslides in Slovenia with a volume of more than 1 mio m3 of moving debris. The landslide is located at the border of Triassic limestone and Eocene flysch formations. Flysch is composed of layers of marls and sandstones. The sliding mass consists mainly of clay and clayey gravel of highly weathered and deteriorated flysch, while a minor part represents grains and blocks of limestones. (Petkovšek et al., 2009). The first documentation of an instability event dates back to 1789 and the landslide was reactivated during a heavy rain period in November 2000. Since then, the ground surface level above the unstable material on the upper zones of the landslide is significantly decreasing so that the current slope surface is now more than 10 m below the terrain surveyed in 1998. The new landslide topography results in different pore pressure distributions in the slope, which were anticipated to have a detrimental effect on the stability and movement regime of the slope. The main goal of this work is to investigate the effect of the overlying debris depth on the pore water pressure distribution during a predefined precipitation scenario. The behaviour of the unsaturated soil and the effects of fissures in the bedrock are also considered in the analysis. Hydro-mechanical simulations were performed using 2D finite element software (PLAXIS) and numerical results are compared with results from analytical models, which use a 1D steady state formulation for the hydraulic part and a 2D limit equilibrium approach to calculate the safety factors. The numerical studies show significant change in the pore water pressure distribution in the landslide body with variation of the debris depth. An increase in the debris depth leads to higher suction due to the deeper location of the water table. Higher suction increases landslide stability due to: i) increase of the effective stress and hence the shear strength of the material and ii

  16. Studying the Effect of Tunnel Depth Variation on the Specific Energy of TBM, Case Study: Karaj–Tehran (Iran Water Conveyance Tunnel

    Directory of Open Access Journals (Sweden)

    Majid Mirahmadi

    2016-09-01

    Full Text Available The tunnel-boring machine (TBM is a common piece of equipment used in tunneling projects. For planning a mechanical excavation project, prediction of TBM performance and the specification of design elements such as required forces are critical. The specific energy of excavation (SE, i.e. drilling energy consumption per unit volume of rock mass, is a crucial parameter for performance prediction of a TBM. In this study, the effect of variation of tunnel depth on SE by considering the post-failure behavior of rock mass was investigated. Several new relations between SE and tunnel depth are proposed according to the statistical analysis obtained from Karaj – Tehran Water Conveyance Tunnel real data. The results showed that there is a direct relation between both parameters and. Polynomial equations are proposed as the best expression of the correlation between these parameters.

  17. Isolation and prayer as means of solace for Arab women with breast cancer: An in-depth interview study.

    Science.gov (United States)

    Assaf, Ghada Najjar; Holroyd, Eleanor; Lopez, Violeta

    2017-11-01

    This study explored Arab women's experiences following the diagnosis and treatment of breast cancer. Face-to-face in-depth interviews were conducted with 20 Arab women attending a public hospital in Abu Dhabi, United Arab Emirates, following a recent diagnosis of breast cancer. All interviews were transcribed verbatim and analysed using the thematic method. Arab women's experiences following their breast cancer diagnoses and treatments included the themes of (1) protecting one's self from stigma, (2) facing uncertainties and prayers, and (3) getting on with life. Overall, the ways to find solace were through isolation and prayer, which are heavily influenced by religion and spiritual practices. They recommended that to help women with breast cancer, a campaign to raise awareness for early screening is needed as well the need to form a peer-led support group for women with breast cancer consisting of breast cancer survivors so that they can learn from each other's experiences. Arab women with breast cancer experienced a myriad of social, cultural, psychological, and relationship difficulties that impacted their overall health and well-being. The findings also found that these women were not passive agents. They sought to solve problem, move forward, and recreate the meanings in their lives in their own unique ways. Action is needed for possible ways to implement religion-health partnerships between breast cancer nurses, peer-led support groups, palliative care services, and religious institutions. Copyright © 2017 John Wiley & Sons, Ltd.

  18. An innovative assessment of the seismic hazard from Vrancea intermediate-depth earthquakes: Case studies in Romania and Bulgaria

    International Nuclear Information System (INIS)

    Panza, G.F.; Cioflan, C.; Marmureanu, G.; Kouteva, M.; Paskaleva, I.; Romanelli, F.

    2002-02-01

    An advanced procedure for ground motion, capable of synthesizing the seismic ground motion from basic understanding of fault mechanism and seismic wave propagation, is applied to the case studies of Bucharest (Romania) and Russe, NE Bulgaria, exposed to the seismic hazard from Vrancea events. Synthetic seismic signals along representative geological cross sections in Bucharest and Russe and been computed and the energetic input spectra have been derived both from the synthetic signals and the few existing records. The theoretical signals are successfully compared with the available observations. The site response has been calculated for three recent, strong and intermediate-depth, Vrancea earthquakes: August 30, 1986 and May 30 and 31, 1990. The used approach differs significantly from today's engineering practice that relays upon rock-site hazard maps and applies the site correction at a later stage. The obtained results show that it is very useful to estimate the site effect via waveform modelling, considering simultaneously the geotechnical properties of the site, the position and geometry of the seismic source and the mechanical properties of the propagation medium. (author)

  19. Penetrating abdominal trauma.

    Science.gov (United States)

    Henneman, P L

    1989-08-01

    The management of patients with penetrating abdominal trauma is outlined in Figure 1. Patients with hemodynamic instability, evisceration, significant gastrointestinal bleeding, peritoneal signs, gunshot wounds with peritoneal violation, and type 2 and 3 shotgun wounds should undergo emergency laparotomy. The initial ED management of these patients includes airway management, monitoring of cardiac rhythm and vital signs, history, physical examination, and placement of intravenous lines. Blood should be obtained for initial hematocrit, type and cross-matching, electrolytes, and an alcohol level or drug screen as needed. Initial resuscitation should utilize crystalloid fluid replacement. If more than 2 liters of crystalloid are needed to stabilize an adult (less in a child), blood should be given. Group O Rh-negative packed red blood cells should be immediately available for a patient in impending arrest or massive hemorrhage. Type-specific blood should be available within 15 minutes. A patient with penetrating thoracic and high abdominal trauma should receive a portable chest x-ray, and a hemo- or pneumothorax should be treated with tube thoracostomy. An unstable patient with clinical signs consistent with a pneumothorax, however, should receive a tube thoracostomy prior to obtaining roentgenographic confirmation. If time permits, a nasogastric tube and Foley catheter should be placed, and the urine evaluated for blood (these procedures can be performed in the operating room). If kidney involvement is suspected because of hematuria or penetrating trauma in the area of a kidney or ureter in a patient requiring surgery, a single-shot IVP should be performed either in the ED or the operating room. An ECG is important in patients with possible cardiac involvement and in patients over the age of 40 going to the operating room. Tetanus status should be updated, and appropriate antibiotics covering bowel flora should be given. Operative management should rarely be delayed

  20. Penetrating cardiothoracic war wounds.

    Science.gov (United States)

    Biocina, B; Sutlić, Z; Husedzinović, I; Rudez, I; Ugljen, R; Letica, D; Slobodnjak, Z; Karadza, J; Brida, V; Vladović-Relja, T; Jelić, I

    1997-03-01

    Penetrating cardiothoracic war wounds are very common among war casualties. Those injuries require prompt and specific treatment in an aim to decrease mortality and late morbidity. There are a few controversies about the best modality of treatment for such injuries, and there are not many large series of such patients in recent literature. We analysed a group of 259 patients with penetrating cardiothoracic war wounds admitted to our institutions between May 1991 and October 1992. There were 235 (90.7%) patients with thoracic wounds, 14 (5.4%) patients with cardiac, wounds and in 10 (3.7%) patients both heart and lungs were injured. The cause of injury was shrapnel in 174 patients (67%), bullets in 25 patients (9.7%), cluster bomb particles in 45 patients (17.3%) and other (blast etc.) in 15 patients (6%). Patients, 69, had concomitant injuries of various organs. The initial treatment in 164 operated patients was chest drainage in 76 (46.3%) patients, thoracotomy and suture of the lung in 71 (43.2%) patients, lobectomy in 12 (7.3%) patients and pneumonectomy in 5 (3%) patients. Complications include pleural empyema and/or lung abscess in 20 patients (8.4%), incomplete reexpansion of the lung in 10 patients (4.2%), osteomyelitis of the rib in 5 patients (2.1%) and bronchopleural fistula in 1 patient (0.4%). Secondary procedures were decortication in 12 patients, rib resection in 5 patients, lobectomy in 2 patients, pneumonectomy in 4 patients, reconstruction of the chest wall in 2 patients and closure of the bronchopleural fistula in 1 patient. The cardiac chamber involved was right ventricle in 12 patients, left ventricular in 6 patients, right atrium in 7 patients, left atrium in 3 patients, ascending aorta in 2 patients and 1 patient which involved descending aorta, right ventricle and coronary artery (left anterior descending) and inferior vena cava, respectively. The primary procedure was suture in 17 patients (in 10 patients with the additional suture of the

  1. Proper target depth of an accelerometer-based feedback device during CPR performed on a hospital bed: a randomized simulation study.

    Science.gov (United States)

    Lee, Sanghyun; Oh, Jaehoon; Kang, Hyunggoo; Lim, Taeho; Kim, Wonhee; Chee, Youngjoon; Song, Yeongtak; Ahn, Chiwon; Cho, Jun Hwi

    2015-10-01

    Feedback devices are used to improve chest compression (CC) quality related to survival rates in cardiac arrest. However, several studies have shown that feedback devices are not sufficiently reliable to ensure adequate CC depth on soft surfaces. Here, we determined the proper target depth of feedback (TDF) using an accelerometer during cardiopulmonary resuscitation in hospital beds. In prospective randomized crossover study, 19 emergency physicians performed CCs for 2 minutes continuously on a manikin in 2 different beds with 3 TDFs (5, 6, and 7 cm). We measured CC depth, the proportion of accurate compression depths, CC rate, the proportion of incomplete chest decompressions, the velocity of CC (CC velocity), the proportion of time spent in CC relative to compression plus decompression (duty cycle), and the time spent in CC (CC time). Mean (SD) CC depths at TDF 5, 6, and 7 were 45.42 (5.79), 52.68 (4.18), and 58.47 (2.48) on one bed and 46.26 (4.49), 53.58 (3.15), and 58.74 (2.10) mm on the other bed (all P.05). The duty cycle differed significantly on only B2. The target depth of the real-time feedback device should be at least 6 cm but should not exceed 7 cm for optimal CC on patients on hospital beds. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Linguistic Intuitions and Cognitive Penetrability

    Directory of Open Access Journals (Sweden)

    Michael Devitt

    2014-12-01

    Full Text Available Metalinguistic intuitions play a very large evidential role in both linguistics and philosophy. Linguists think that these intuitions are products of underlying linguistic competence. I call this view “the voice of competence” (“VoC”. Although many philosophers seem to think that metalinguistic intuitions are a priori many may implicitly hold the more scientifically respectable VoC. According to VoC, I argue, these intuitions can be cognitively penetrated by the central processor. But, I have argued elsewhere, VoC is false. Instead, we should hold “the modest explanation” (“ME” according to which these intuitions are fairly unreflective empirical theory-laden central-processor responses to phenomena. On ME, no question of cognitive penetration arises. ME has great methodological significance for the study of language. Insofar as we rely on intuitions as evidence we should prefer those of linguists and philosophers because they are more expert. But, more importantly, we should be seeking other evidence in linguistic usage.

  3. Young women's accounts of factors influencing their use and non-use of emergency contraception: in-depth interview study

    Science.gov (United States)

    Free, Caroline; Lee, Raymond M; Ogden, Jane

    2002-01-01

    Objectives To explore young women's accounts of their use and non-use of emergency contraception. Design Qualitative study using in-depth interviews. Participants 30 women aged 16-25; participants from socially deprived inner city areas were specifically included. Setting Community, service, and educational settings in England. Results Young women's accounts of their non-use of emergency contraception principally concerned evaluations of the risk conferred by different contraceptive behaviours, their evaluations of themselves in needing emergency contraception, and personal difficulties in asking for emergency contraception. Conclusions The attitudes and concerns of young women, especially those from disadvantaged backgrounds, may make them less able or willing than others to take advantage of recent increases in access to emergency contraception. Interventions that aim to increase the use of emergency contraception need to address the factors that influence young women's non-use of emergency contraception. What is already known on this topicLimited knowledge of, or poor access to, emergency contraception, and concerns about side effects and moral issues may reduce the use of emergency contraception in women at riskYoung people can be embarrassed about using contraception servicesInterventions to increase knowledge of and access to emergency contraception have had limited success among teenagersWhat this study addsPerceptions of low vulnerability to pregnancy, negative self evaluations about the need for such contraception, and concerns about what others think deter young women from using emergency contraceptionThese women find it difficult to ask for emergency contraceptionThe attitudes and concerns of young women, especially those from deprived inner city areas, may render them least willing and able to obtain emergency contraception PMID:12480855

  4. The use of Ground Penetrating Radar in coastal research, archeaological investigations, lake studies, peat layer measurments and applied research in Estonia

    Science.gov (United States)

    Vilumaa, Kadri; Tõnisson, Hannes; Orviku, Kaarel

    2014-05-01

    Ground Penetrating Radar (GPR) is mainly used for scientific research in coastal geology in the Institute of Ecology at Tallinn University. We currently use SIR-3000 radar with 100, 270 , 300 and 500 MHz antennae. Our main targets have been detecting the thickness of soil and sand layers and finding out the layers in coastal sediments which reflect extreme storm events. Our GPR studies in various settings have suggested that the internal structures of the ridge-dune complexes are dominated by numerous layers dipping in various directions. Such information helps us to reconstruct and understand prevailing processes during their formation (e.g. seaward dipping lamination in coastal ridge-dune complexes indicating cross-shore and wave-induced transport of the sediments). Currently, we are trying to elaborate methodology for distinguishing the differences between aeolian and wave transported sediments by using GPR. However, paludified landscapes (often covered by water), very rough surface (numerous bushes and soft surface), moderate micro topography has slowed this process significantly. Moreover, we have been able to use GPR during the winter period (applied on ice or snow) and compare the quality of our results with the measurements taken during the summer period. We have found that smooth surface (in winter) helps detecting very strong signal differences (border between different sediment types - sand, peat, silt, etc.) but reduces the quality of the signal to the level where the detection of sedimentation patterns within one material (e.g. tilted layers in sand) is difficult. We have carried out several other science-related studies using GPR. These studies include determining the thickness of peat layer in bogs (to calculate the volume of accumulated peat or to find most suitable locations for coring), measuring the thickness of mud and gyttja layer in lakes (to find most suitable locations for coring, reconstructing initial water level of the lake or calculating

  5. A Case Study on the Perceptions of Educators on the Penetration of Personal Learning Environments in Typical Education

    Science.gov (United States)

    Armakolas, Stefanos; Mikroyannidis, Alexander; Panagiotakopoulos, Christos; Panousopoulou, Theofania

    2016-01-01

    Personal Learning Environments (PLEs) help students manage and take control of their own learning. As such, the PLE promotes self-regulation in learning and allows learners to aggregate, manipulate and share digital artefacts within a flexible and versatile online space. This paper presents a case study in Greece, concerning an investigation about…

  6. Trophic diversity, size and biomass spectrum of Bay of Bengal nematodes: A study case on depth and latitudinal patterns

    Science.gov (United States)

    Ansari, Kapuli Gani Mohamed Thameemul; Lyla, Somasundharanair; Khan, Syed Ajmal; Bhadury, Punyasloke

    2017-09-01

    Depth and latitudinal patterns of nematode functional attributes were investigated from 35 stations of Bay of Bengal (BoB) continental shelf. We aim to address whether depth and latitudinal variations can modify nematode community structure and their functional attributes (trophic diversity, size and biomass spectra). Global trend of depth and latitudinal related variations have also been noticed from BoB shelf in terms of nematode abundance and species richness, albeit heterogeneity patterns were encountered in functional attributes. Index of trophic diversity values revealed higher trophic diversity across the BoB shelf and suggested variety of food resource availability. However, downstream analysis of trophic status showed depth and latitude specific patterns but not reflected in terms of size and biomass spectrum. The peaks at different positions clearly visualized heterogeneity in distribution patterns for both size and biomass spectrum and also there was evidence of availability of diversified food resources. Nematode biomass spectra (NBS) constructed for nematode communities showed shift in peak biomass values towards lower to moderate size classes particularly in shallower depth but did not get reflected in latitudes. However, Chennai and Parangipettai transects demonstrated shift in peak biomass values towards higher biomass classes explaining the representation of higher nematode abundance. Our findings concluded that depth and latitudes are physical variables; they may not directly affect nematode community structure and functional attributes but they might influence the other factors such as food availability, sediment deposition and settlement rate. Our observations suggest that the local factors (seasonal character) of phytodetrital food flux can be very important for shaping the nematode community structure and success of nematode functional heterogeneity patterns across the Bay of Bengal shelf.

  7. Penetration Tester's Open Source Toolkit

    CERN Document Server

    Faircloth, Jeremy

    2011-01-01

    Great commercial penetration testing tools can be very expensive and sometimes hard to use or of questionable accuracy. This book helps solve both of these problems. The open source, no-cost penetration testing tools presented do a great job and can be modified by the user for each situation. Many tools, even ones that cost thousands of dollars, do not come with any type of instruction on how and in which situations the penetration tester can best use them. Penetration Tester's Open Source Toolkit, Third Edition, expands upon existing instructions so that a professional can get the most accura

  8. Penetration analysis of projectile with inclined concrete target

    Directory of Open Access Journals (Sweden)

    Kim S.B.

    2015-01-01

    Full Text Available This paper presents numerical analysis result of projectile penetration with concrete target. We applied dynamic material properties of 4340 steels, aluminium and explosive for projectile body. Dynamic material properties were measured with static tensile testing machine and Hopkinson pressure bar tests. Moreover, we used three concrete damage models included in LS-DYNA 3D, such as SOIL_CONCRETE, CSCM (cap model with smooth interaction and CONCRETE_DAMAGE (K&C concrete models. Strain rate effect for concrete material is important to predict the fracture deformation and shape of concrete, and penetration depth for projectiles. CONCRETE_DAMAGE model with strain rate effect also applied to penetration analysis. Analysis result with CSCM model shows good agreement with penetration experimental data. The projectile trace and fracture shapes of concrete target were compared with experimental data.

  9. Spatiotemporal Dynamics of Soil Penetration Resistance of Recultivated Soil

    Directory of Open Access Journals (Sweden)

    Zadorozhnaya Galina

    2018-03-01

    Full Text Available This article examines changes in the spatial distribution of soil penetration resistance in ordinary chernozem (Calcic Chernozem and in the recultivated soil in 2012 and 2014. The measurements were carried out in the field using an Eijkelkamp penetrometer on a regular grid. The depth of measurement was 50 cm, the interval was 5 cm. The indices of variation of soil penetration resistance in space and time have been determined. The degree of spatial dependence of soil penetration resistance has been determined layer by layer. The nature of temporal dynamics of soil penetration resistance of chernozem and technical soil has been described. A significant positive relationship of the structure of chernozem in the two years of the research has been shown. Significant correlations between the data of different years in the technical soil were found to be mostly negative.

  10. Penetration analysis of projectile with inclined concrete target

    Science.gov (United States)

    Kim, S. B.; Kim, H. W.; Yoo, Y. H.

    2015-09-01

    This paper presents numerical analysis result of projectile penetration with concrete target. We applied dynamic material properties of 4340 steels, aluminium and explosive for projectile body. Dynamic material properties were measured with static tensile testing machine and Hopkinson pressure bar tests. Moreover, we used three concrete damage models included in LS-DYNA 3D, such as SOIL_CONCRETE, CSCM (cap model with smooth interaction) and CONCRETE_DAMAGE (K&C concrete) models. Strain rate effect for concrete material is important to predict the fracture deformation and shape of concrete, and penetration depth for projectiles. CONCRETE_DAMAGE model with strain rate effect also applied to penetration analysis. Analysis result with CSCM model shows good agreement with penetration experimental data. The projectile trace and fracture shapes of concrete target were compared with experimental data.

  11. Thermal Behavior of the Reactor Vessel Penetration Under External Vessel Cooling During a Severe Accident

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Park, Rae-Joon; Kim, Jong-Tae; Min, Byung-Tae; Lee, Ki-Young; Kim, Sang-Baik

    2004-01-01

    Experimental and analytical studies on the thermal behavior of reactor vessel penetration have been performed under external vessel cooling during a severe accident in the Korean next-generation reactor APR1400. Two types of tests, SUS-EXT and SUS-DRY with and without external vessel cooling, respectively, have been performed using sustained heating by an induction heater. Three tests have been carried out varying the cooling conditions at the vessel outer surface in the SUS-EXT tests. The experimental results have been thermally estimated using the LILAC computer code. The experimental results indicate that the inner surface of the vessel was ablated by the 45-mm thickness in the SUS-DRY test. Despite the total ablation of the welding material, the penetration was not ejected outside the vessel, which could be attributed to the thermal expansion of the penetration. Unlike the SUS-DRY test, the thickness of the ablation was ∼15 to 20 mm at most, so the welding was preserved in the SUS-EXT tests. It is concluded from the experimental results that the external vessel cooling highly affected the ablation configuration and the thermal behaviors of the vessel and the penetration. An increase in coolant mass flow rate from 0.047 to 0.152 kg/s had effects on the thermal behavior of the lower head vessel and penetration in the SUS-EXT tests. The LILAC analytical results on temperature distribution and ablation depth in the lower head vessel and penetration were very similar to the experimental results

  12. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal; Schott, Mathias; Bonneau, Georges-Pierre; Hansen, Charles D.

    2013-01-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  13. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal

    2013-02-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  14. A study of the impact of environmental loads that penetrate a passive skylight roofing system in Malaysian buildings

    Directory of Open Access Journals (Sweden)

    Karam M. Al-Obaidi

    2014-06-01

    Full Text Available A passive skylight system is a significant building design element that provides an ideal condition for interior spaces. However, the use of this system is limited to specific climatic regions because of its considerable effect on the indoor environment. Malaysia is a tropical country that has favorable natural benefits, such as solar geometry and natural light, which can brighten building interiors throughout the year. However, harnessing this benefit affects spaces, especially those in single-story buildings, because of excessive natural loads. This study reviews a concept to understand the passive behavior of solar radiation in the form of light and heat that falls on, interacts with, and is emitted from a skylight system in a single-story building. The study method is theoretically based on descriptive analysis to assess design requirements. The review shows that designs grounded on the physical aspects of climate (influenced variables, materials (design variables, and human comfort (affected variables in one process (ESI can develop the architectural way of thinking rather than estimate the condition based on a limited perspective. This assumption indicates that the adoption of this concept in the preliminary design stage will enable designers to balance the building environment effectively.

  15. Experimental study of a depth-encoding PET detector inserting horizontal-striped glass between crystal layers

    Science.gov (United States)

    Yang, J.; Kim, K. B.; Choi, Y.; Kang, J.

    2018-04-01

    A depth-encoding positron emission tomography (PET) detector inserting a horizontal-striped glass between pixilated scintillation crystal layers was developed and experimentally evaluated. The detector consists of 2-layers of 4×4 LYSO array arranged with a 3.37 mm pitch. Horizontal-striped glasses with 1×4 array with different thickness of 3, 4 and 5 mm were inserted between top- and bottom-crystal layers. Bottom surface of bottom-layer was optically coupled to a 4×4 GAPD array. Sixteen output signals from DOI-PET detector were multiplexed by modified resistive charge division (RCD) networks and multiplexed signals were fed into custom-made charge-sensitive preamplifiers. The four amplified signals were digitized and recorded by the custom-made DAQ system based on FPGA. The four digitized outputs were post-processed and converted to flood histograms for each interaction event. Experimental results revealed that all crystal pixels were clearly identified on the 2D flood histogram without overlapping. Patterns of the 2D flood histogram were constituted with arrangements of [bottom–top–bottom–top–\\ldots–top–bottom–top–bottom] crystal responses in X-direction. These could be achieved by employing horizontal-striped glass that controlled the extent of light dispersion towards the X-direction in crystal layers for generation of a different position mapping for each layer and the modified RCD network that controls degree of charge sharing in readout electronics for reduction of identification error. This study demonstrated the proposed DOI-PET detector can extract the 3D γ-ray interaction position without considerable performance degradation of PET detector from the 2D flood histogram.

  16. SNOW DEPTH ESTIMATION USING TIME SERIES PASSIVE MICROWAVE IMAGERY VIA GENETICALLY SUPPORT VECTOR REGRESSION (CASE STUDY URMIA LAKE BASIN

    Directory of Open Access Journals (Sweden)

    N. Zahir

    2015-12-01

    Full Text Available Lake Urmia is one of the most important ecosystems of the country which is on the verge of elimination. Many factors contribute to this crisis among them is the precipitation, paly important roll. Precipitation has many forms one of them is in the form of snow. The snow on Sahand Mountain is one of the main and important sources of the Lake Urmia’s water. Snow Depth (SD is vital parameters for estimating water balance for future year. In this regards, this study is focused on SD parameter using Special Sensor Microwave/Imager (SSM/I instruments on board the Defence Meteorological Satellite Program (DMSP F16. The usual statistical methods for retrieving SD include linear and non-linear ones. These methods used least square procedure to estimate SD model. Recently, kernel base methods widely used for modelling statistical problem. From these methods, the support vector regression (SVR is achieved the high performance for modelling the statistical problem. Examination of the obtained data shows the existence of outlier in them. For omitting these outliers, wavelet denoising method is applied. After the omission of the outliers it is needed to select the optimum bands and parameters for SVR. To overcome these issues, feature selection methods have shown a direct effect on improving the regression performance. We used genetic algorithm (GA for selecting suitable features of the SSMI bands in order to estimate SD model. The results for the training and testing data in Sahand mountain is [R²_TEST=0.9049 and RMSE= 6.9654] that show the high SVR performance.

  17. Physical Penetration Testing: A Whole New Story in Penetration Testing

    NARCIS (Netherlands)

    Dimkov, T.; Pieters, Wolter

    2011-01-01

    Physical penetration testing plays an important role in assuring a company that the security policies are properly enforced and that the security awareness of the employees is on the appropriate level. In physical penetration tests the tester physically enters restricted locations and directly

  18. Low-energy Bluetooth for detecting real-world penetrance of bystander naloxone kits: a pilot study.

    Science.gov (United States)

    Lai, Jeffrey T; Chapman, Brittany P; Boyle, Katherine L; Boyer, Edward W; Chai, Peter R

    2018-01-03

    Opioid overdose is a growing public health emergency in the United States. The antidote naloxone must be administered rapidly after opioid overdose to prevent death. Bystander or "take-home" naloxone programs distribute naloxone to opioid users and other community members to increase naloxone availability at the time of overdose. However, data describing the natural history of take-home naloxone in the hands of at-risk individuals is lacking. To understand patterns of naloxone uptake in at-risk users, we developed a smart naloxone kit that uses low-energy Bluetooth (BLE) to unobtrusively detect the transit of naloxone through a hospital campus. In this paper, we describe development of the smart naloxone kit and results from the first 10 participants in our pilot study.

  19. Improved Skin Penetration Using In Situ Nanoparticulate Diclofenac Diethylamine in Hydrogel Systems: In Vitro and In Vivo Studies.

    Science.gov (United States)

    Sengupta, Soma; Banerjee, Sarita; Sinha, Biswadip; Mukherjee, Biswajit

    2016-04-01

    Delivering diclofenac diethylamine transdermally by means of a hydrogel is an approach to reduce or avoid systemic toxicity of the drug while providing local action for a prolonged period. In the present investigation, a process was developed to produce nanosize particles (about 10 nm) of diclofenac diethylamine in situ during the development of hydrogel, using simple mixing technique. Hydrogel was developed with polyvinyl alcohol (PVA) (5.8% w/w) and carbopol 71G (1.5% w/w). The formulations were evaluated on the basis of field emission scanning electron microscopy, texture analysis, and the assessment of various physiochemical properties. Viscosity (163-165 cps for hydrogel containing microsize drug particles and 171-173 cps for hydrogel containing nanosize drug particles, respectively) and swelling index (varied between 0.62 and 0.68) data favor the hydrogels for satisfactory topical applications. The measured hardness of the different hydrogels was uniform indicating a uniform spreadability. Data of in vitro skin (cadaver) permeation for 10 h showed that the enhancement ratios of the flux of the formulation containing nanosize drug (without the permeation enhancer) were 9.72 and 1.30 compared to the formulation containing microsized drug and the marketed formulations, respectively. In vivo plasma level of the drug increased predominantly for the hydrogel containing nanosize drug-clusters. The study depicts a simple technique for preparing hydrogel containing nanosize diclofenac diethylamine particles in situ, which can be commercially viable. The study also shows the advantage of the experimental transdermal hydrogel with nanosize drug particles over the hydrogel with microsize drug particles.

  20. MOD-AGE - an algorithm for age-depth model construction; U-series dated speleothems case study

    Science.gov (United States)

    Hercman, H.; Pawlak, J.

    2012-04-01

    We present MOD-AGE - a new system for chronology construction. MOD-AGE can be used for profiles that have been dated by different methods. As input data, the system uses the following basic measurements: activities, atomic ratios or age, as well as depth measurement. Based on probability distributions describing the measurement results, MOD-AGE estimates the age~depth relation and its confidence bands. To avoid the use of difficult-to-meet assumptions, MOD-AGE uses nonparametric methods. We applied a Monte Carlo simulation to model age and depth values based on the real distribution of counted data (activities, atomic ratios,