WorldWideScience

Sample records for pelvic nodal irradiation

  1. Mapping of nodal disease in locally advanced prostate cancer: Rethinking the clinical target volume for pelvic nodal irradiation based on vascular rather than bony anatomy

    International Nuclear Information System (INIS)

    Shih, Helen A.; Harisinghani, Mukesh; Zietman, Anthony L.; Wolfgang, John A.; Saksena, Mansi; Weissleder, Ralph

    2005-01-01

    Purpose: Toxicity from pelvic irradiation could be reduced if fields were limited to likely areas of nodal involvement rather than using the standard 'four-field box.' We employed a novel magnetic resonance lymphangiographic technique to highlight the likely sites of occult nodal metastasis from prostate cancer. Methods and Materials: Eighteen prostate cancer patients with pathologically confirmed node-positive disease had a total of 69 pathologic nodes identifiable by lymphotropic nanoparticle-enhanced MRI and semiquantitative nodal analysis. Fourteen of these nodes were in the para-aortic region, and 55 were in the pelvis. The position of each of these malignant nodes was mapped to a common template based on its relation to skeletal or vascular anatomy. Results: Relative to skeletal anatomy, nodes covered a diffuse volume from the mid lumbar spine to the superior pubic ramus and along the sacrum and pelvic side walls. In contrast, the nodal metastases mapped much more tightly relative to the large pelvic vessels. A proposed pelvic clinical target volume to encompass the region at greatest risk of containing occult nodal metastases would include a 2.0-cm radial expansion volume around the distal common iliac and proximal external and internal iliac vessels that would encompass 94.5% of the pelvic nodes at risk as defined by our node-positive prostate cancer patient cohort. Conclusions: Nodal metastases from prostate cancer are largely localized along the major pelvic vasculature. Defining nodal radiation treatment portals based on vascular rather than bony anatomy may allow for a significant decrease in normal pelvic tissue irradiation and its associated toxicities

  2. Impact of pelvic nodal irradiation with intensity-modulated radiotherapy on treatment of prostate cancer

    International Nuclear Information System (INIS)

    Price, Robert A.; Hannoun-Levi, Jean-Michel; Horwitz, Eric; Buyyounouski, Mark; Ruth, Karen J.; Ma, C.-M.; Pollack, Alan

    2006-01-01

    Purpose: The aim of this study was to evaluate the feasibility of treating the pelvic lymphatic regions during prostate intensity-modulated radiotherapy (IMRT) with respect to our routine acceptance criteria. Methods and Materials: A series of 10 previously treated prostate patients were randomly selected and the pelvic lymphatic regions delineated on the fused magnetic resonance/computed tomography data sets. A targeting progression was formed from the prostate and proximal seminal vesicles only to the inclusion of all pelvic lymphatic regions and presacral region resulting in 5 planning scenarios of increasing geometric difficulty. IMRT plans were generated for each stage for two accelerator manufacturers. Dose volume histogram data were analyzed with respect to dose to the planning target volumes, rectum, bladder, bowel, and normal tissue. Analysis was performed for the number of segments required, monitor units, 'hot spots,' and treatment time. Results: Both rectal endpoints were met for all targets. Bladder endpoints were not met and the bowel endpoint was met in 40% of cases with the inclusion of the extended and presacral lymphatics. A significant difference was found in the number of segments and monitor units with targeting progression and between accelerators, with the smaller beamlets yielding poorer results. Treatment times between the 2 linacs did not exhibit a clinically significant difference when compared. Conclusions: Many issues should be considered with pelvic lymphatic irradiation during IMRT delivery for prostate cancer including dose per fraction, normal structure dose/volume limits, planning target volumes generation, localization, treatment time, and increased radiation leakage. We would suggest that, at a minimum, the endpoints used in this work be evaluated before beginning IMRT pelvic nodal irradiation

  3. Dose-Volume Relationships for Acute Bowel Toxicity in Patients Treated With Pelvic Nodal Irradiation for Prostate Cancer

    International Nuclear Information System (INIS)

    Fiorino, Claudio; Alongi, Filippo; Perna, Lucia; Broggi, Sara; Cattaneo, Giovanni Mauro; Cozzarini, Cesare; Di Muzio, Nadia; Fazio, Ferruccio; Calandrino, Riccardo

    2009-01-01

    Purpose: To find correlation between dose-volume histograms (DVHs) of the intestinal cavity (IC) and moderate-severe acute bowel toxicity in men with prostate cancer treated with pelvic nodal irradiation. Methods and Materials: The study group consisted of 191 patients with localized prostate cancer who underwent whole-pelvis radiotherapy with radical or adjuvant/salvage intent during January 2004 to November 2007. Complete planning/clinical data were available in 175 of these men, 91 of whom were treated with a conventional four-field technique (50.4 Gy, 1.8 Gy/fraction) and 84 of whom were treated with IMRT using conventional Linac (n = 26, 50.4 Gy, 1.8 Gy/fraction) or Helical TomoTherapy (n = 58, 50-54 Gy, 1.8-2 Gy/fraction). The IC outside the planning target volume (PTV) was contoured and the DVH for the first 6 weeks of treatment was recovered in all patients. The correlation between a number of clinical and DVH (V10-V55) variables and toxicity was investigated in univariate and multivariate analyses. The correlation between DVHs for the IC outside the PTV and DVHs for the whole IC was also assessed. Results: Twenty-two patients experienced toxicity (3/22 in the IMRT/tomotherapy group). Univariate analyses showed a significant correlation between V20-V50 and toxicity (p = 0.0002-0.001), with a higher predictive value observed for V40-V50. Previous prostatectomy (p = 0.066) and abdominal/pelvic surgery (p = 0.12) also correlated with toxicity. Multivariate analysis that included V45, abdominal/pelvic surgery, and prostatectomy showed that the most predictive parameters were V45 (p = 0.002) and abdominal/pelvic surgery (p = 0.05, HR = 2.4) Conclusions: Our avoidance IMRT approach drastically reduces the incidence of acute bowel toxicity. V40-V50 of IC and, secondarily, previous abdominal/pelvic surgery were the main predictors of acute bowel toxicity.

  4. Quality of Life after Post-Prostatectomy Intensity Modulated Radiation Therapy: Pelvic Nodal Irradiation Is Not Associated with Worse Bladder, Bowel, or Sexual Outcomes.

    Directory of Open Access Journals (Sweden)

    James M Melotek

    Full Text Available Limited data exist regarding toxicity and quality of life (QOL after post-prostatectomy intensity modulated radiation therapy (IMRT and whether pelvic nodal RT influences these outcomes.118 men were treated with curative-intent RT after radical prostatectomy. 69 men (58% received pelvic nodal RT. QOL data and physician-assigned toxicity were prospectively collected. Changes in QOL from baseline were assessed with Wilcoxon signed-rank tests and risk factors associated with each domain were identified with generalized estimating equation (GEE models. Late freedom from (FF toxicity was estimated by the Kaplan-Meier method and comparisons were tested using the log-rank test.Urinary irritation/obstruction, bowel, and sexual domain scores declined at 2 months (all P ≤ 0.01 but were no different than baseline at subsequent visits through 4 years of follow-up. At 4 years, FF grade 2+ GI toxicity was 90% and FF grade 2+ GU toxicity was 89%. On GEE analysis, pelvic nodal RT was associated with decreased bowel function (P = 0.09 and sexual function (P = 0.01. On multivariate analysis, however, there was no significant association with either decreased bowel (P = 0.31 or sexual (P = 0.84 function. There was also no association with either FF grade 2+ GI toxicity (P = 0.24 or grade 2+ GU toxicity (P = 0.51.Receipt of pelvic nodal RT was not associated with inferior QOL or toxicity compared to prostate bed alone RT. For the entire cohort, RT was associated with only temporary declines in patient-reported urinary, bowel, or sexual QOL.

  5. Node-positive cervical cancer: impact of pelvic irradiation and patterns of failure

    International Nuclear Information System (INIS)

    Stock, Richard G.; Chen, Alex S. J.; Flickinger, John C.; Kalnicki, Shalom; Seski, Jan

    1995-01-01

    Purpose: The roles of postoperative pelvic and prophylactic paraaortic irradiation in pelvic node positive cervical cancer are currently controversial. A retrospective study was undertaken to examine the effect of pelvic irradiation on pelvic control and survival and to analyze the patterns of recurrence to determine whether indications exist for prophylactic paraaortic irradiation. Methods and Materials: From 1964 to 1991, 143 cases of FIGO Stage I and II cervical cancer undergoing exploratory laparotomy, pelvic lymph node dissection, and radical hysterectomy had positive pelvic lymph nodes. Postoperatively, 108 cases were treated with whole pelvic irradiation while 35 patients were observed. Prophylactic paraaortic irradiation was not given. Results: Patients who received postoperative whole pelvic irradiation compared with those treated with radical hysterectomy alone had a significantly improved pelvic control rate, disease-free survival (DFS), and overall survival. The 5-year actuarial pelvic control rate was 78% vs. 45% (p = <0.0001), respectively. The 5-year actuarial DFS was 65% vs. 41% (p = 0.0004). The 5-year actuarial overall survival was 58% vs. 46% (p 0.02). In multivariate analysis, pelvic irradiation continued to show a positive effect on DFS (p = 0.0001) and overall survival (p = 0.0035). Lymphatic invasion and the total number of positive lymph nodes were the only other independent predictors of overall survival and DFS. The actuarial 5-year pelvic, paraaortic, and distant failure rates were 30%, 10%, and 28%, respectively. An isolated first recurrence in the paraaortic nodes occurred in only three cases. Conclusion: Postoperative pelvic irradiation significantly improves pelvic control, DFS, and overall survival, and should be used in patients with early stage cervical cancer and pathologically proven pelvic nodal metastases. The low incidence of isolated paraaortic nodal failure calls into question the value of routine prophylactic paraaortic

  6. Node-positive cervical cancer: impact of pelvic irradiation and patterns of failure

    Energy Technology Data Exchange (ETDEWEB)

    Stock, Richard G; Chen, Alex S. J.; Flickinger, John C; Kalnicki, Shalom; Seski, Jan

    1995-01-01

    Purpose: The roles of postoperative pelvic and prophylactic paraaortic irradiation in pelvic node positive cervical cancer are currently controversial. A retrospective study was undertaken to examine the effect of pelvic irradiation on pelvic control and survival and to analyze the patterns of recurrence to determine whether indications exist for prophylactic paraaortic irradiation. Methods and Materials: From 1964 to 1991, 143 cases of FIGO Stage I and II cervical cancer undergoing exploratory laparotomy, pelvic lymph node dissection, and radical hysterectomy had positive pelvic lymph nodes. Postoperatively, 108 cases were treated with whole pelvic irradiation while 35 patients were observed. Prophylactic paraaortic irradiation was not given. Results: Patients who received postoperative whole pelvic irradiation compared with those treated with radical hysterectomy alone had a significantly improved pelvic control rate, disease-free survival (DFS), and overall survival. The 5-year actuarial pelvic control rate was 78% vs. 45% (p = <0.0001), respectively. The 5-year actuarial DFS was 65% vs. 41% (p = 0.0004). The 5-year actuarial overall survival was 58% vs. 46% (p 0.02). In multivariate analysis, pelvic irradiation continued to show a positive effect on DFS (p = 0.0001) and overall survival (p = 0.0035). Lymphatic invasion and the total number of positive lymph nodes were the only other independent predictors of overall survival and DFS. The actuarial 5-year pelvic, paraaortic, and distant failure rates were 30%, 10%, and 28%, respectively. An isolated first recurrence in the paraaortic nodes occurred in only three cases. Conclusion: Postoperative pelvic irradiation significantly improves pelvic control, DFS, and overall survival, and should be used in patients with early stage cervical cancer and pathologically proven pelvic nodal metastases. The low incidence of isolated paraaortic nodal failure calls into question the value of routine prophylactic paraaortic

  7. Regional Nodal Irradiation in Early-Stage Breast Cancer.

    Science.gov (United States)

    Whelan, Timothy J; Olivotto, Ivo A; Parulekar, Wendy R; Ackerman, Ida; Chua, Boon H; Nabid, Abdenour; Vallis, Katherine A; White, Julia R; Rousseau, Pierre; Fortin, Andre; Pierce, Lori J; Manchul, Lee; Chafe, Susan; Nolan, Maureen C; Craighead, Peter; Bowen, Julie; McCready, David R; Pritchard, Kathleen I; Gelmon, Karen; Murray, Yvonne; Chapman, Judy-Anne W; Chen, Bingshu E; Levine, Mark N

    2015-07-23

    Most women with breast cancer who undergo breast-conserving surgery receive whole-breast irradiation. We examined whether the addition of regional nodal irradiation to whole-breast irradiation improved outcomes. We randomly assigned women with node-positive or high-risk node-negative breast cancer who were treated with breast-conserving surgery and adjuvant systemic therapy to undergo either whole-breast irradiation plus regional nodal irradiation (including internal mammary, supraclavicular, and axillary lymph nodes) (nodal-irradiation group) or whole-breast irradiation alone (control group). The primary outcome was overall survival. Secondary outcomes were disease-free survival, isolated locoregional disease-free survival, and distant disease-free survival. Between March 2000 and February 2007, a total of 1832 women were assigned to the nodal-irradiation group or the control group (916 women in each group). The median follow-up was 9.5 years. At the 10-year follow-up, there was no significant between-group difference in survival, with a rate of 82.8% in the nodal-irradiation group and 81.8% in the control group (hazard ratio, 0.91; 95% confidence interval [CI], 0.72 to 1.13; P=0.38). The rates of disease-free survival were 82.0% in the nodal-irradiation group and 77.0% in the control group (hazard ratio, 0.76; 95% CI, 0.61 to 0.94; P=0.01). Patients in the nodal-irradiation group had higher rates of grade 2 or greater acute pneumonitis (1.2% vs. 0.2%, P=0.01) and lymphedema (8.4% vs. 4.5%, P=0.001). Among women with node-positive or high-risk node-negative breast cancer, the addition of regional nodal irradiation to whole-breast irradiation did not improve overall survival but reduced the rate of breast-cancer recurrence. (Funded by the Canadian Cancer Society Research Institute and others; MA.20 ClinicalTrials.gov number, NCT00005957.).

  8. Prophylactic ibuprofed administration during pelvic irradiation

    International Nuclear Information System (INIS)

    Stryker, J.A.; Demers, L.M.; Mortel, R.

    1979-01-01

    Thirty-five patients who were to begin pelvic irradiation for malignant disease were randomized to receive ibuprofen 400 mg P.O. q.i.d. during their radiotherapy or standard therapy for radiation-induced gastrointestinal symptoms. Seventeen of 19 patients in the ibuprofen group completed the protocol. There was no significant difference in the daily stool frequency between the ibuprofen and control patients during the 5 to 6 week course of pelvic irradiation; the incidence and severity of diarrhea was the same. There was no significant difference in the incidence of nausea reported by the patients but the severity of nausea was less in the ibuprofen group; none of the 17 patients in the ibuprofen group reported vomiting at any time, whereas, 27% of the patients in the control group reported vomiting. The difference was statistically significant (p < 0.05). The data suggest that prophylactic ibuprofen administration may be beneficial in reducing the severity of nausea and preventing radiation-induced vomiting in patients who receive pelvic irradiation

  9. Pelvic fractures following irradiation for endometrial carcinoma

    International Nuclear Information System (INIS)

    Konski, Andre; Sowers, Maryfran

    1996-01-01

    Purpose: To investigate the incidence and etiologic factors of pelvic fractures following radiation therapy for endometrial carcinoma. Methods and Materials: Tumor registry and radiation oncology records of patients treated for endometrial carcinoma at The Toledo Hospital between April 1989, and December 1992, were reviewed. Patients identified as having pelvic fractures without the presence of metastatic disease underwent total body mineral density measurement with dual x-ray densitometry. Results: Two of 75 patients (2.7%) were found to have pelvic fractures an average of 29 months from the completion of postoperative irradiation. One patient, who received preoperative irradiation, was also identified as having developed a fracture of the pelvis and was included in the analysis. All patients were treated prone with 10-15 MV photons in four fields daily. All three fracture patients received 45 Gy external beam radiation therapy. The two postoperative patients each received a single vaginal brachytherapy application delivering 20 Gy to 0.5 cm deep to the vaginal mucosa with a vaginal cylinder containing 30 mgRaeq 137 Cs. The preoperative patient received a single brachytherapy application with tandem and colpostats delivering 20 Gy to point A. Only one of the three fracture patients had the entire pubis included in the field of external beam treatment. One patient was taking nonsteroidal anti-inflammatory medication, one patient thyroid hormone replacement, and one patient was taking both types of medication. Conclusion: The etiology of pelvic fractures after irradiation is multifactorial. A complete medication history should be obtained, and care should be exercised in positioning the radiation fields to avoid inclusion of the entire pubis prior to the initiation of the radiation treatment

  10. Effect of pelvic irradiation of lactose absorption

    International Nuclear Information System (INIS)

    Stryker, J.A.; Mortel, R.; Hepner, G.W.

    1978-01-01

    Twenty-four patients undergoing pelvic irradiation for gynecologic malignancies had 14 C-lactose breath tests performed in the first and fifth weeks of their treatment. The 14 C-lactose breath test was performed by administering 2 μCi of 14 C-lactose by mouth along with 50 g of lactose. Breath samples were collected in ethanolic hyamine 1, 2, and 3 hr later; the radioactivity of the trapped 14 CO 2 was determined by liquid scintillation spectroscopy. In the first week of treatment the percentage of administered 14 C excreted as 14 CO 2 at 1, 2, and 3 hr was 1.7 +- 0.8% (mean +- SD), 4.5 +- 1.6%, and 5.8 +- 1.4%, respectively. In the fifth week of treatment the 1-hr, 2-hr, and 3-hr values were 1.2 +- 0.9%, 3.6 +- 2.0%, and 4.7 +- 1.9%, respectively. The difference between the first week and fifth week test results at 1, 2, and 3 hr was statistically significant (t = 2.64, p 14 C-lactose breath test results in the fifth week and the stool frequency at that time (r = -0.44, p 14 C-lactose breath test results in the fifth week were below normal (<1.2%) had nausea at that time. The data suggest that in some patients, lactose malabsorption as a result of the effect of radiation on small intestinal function may be etiologically related to the symptoms of nausea and diarrhea which occur commonly in patients who are undergoing pelvic irradiation. In addition, the results suggest that lactose-containing foods should be restricted in some patients who are undergoing pelvic irradiation to prevent symptoms resulting from radiation-induced lactose intolerance

  11. Phase I Trial of Pelvic Nodal Dose Escalation With Hypofractionated IMRT for High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Adkison, Jarrod B.; McHaffie, Derek R.; Bentzen, Soren M.; Patel, Rakesh R.; Khuntia, Deepak [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Petereit, Daniel G. [Department of Radiation Oncology, John T. Vucurevich Regional Cancer Care Institute, Rapid City Regional Hospital, Rapid City, SD (United States); Hong, Theodore S.; Tome, Wolfgang [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Ritter, Mark A., E-mail: ritter@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States)

    2012-01-01

    Purpose: Toxicity concerns have limited pelvic nodal prescriptions to doses that may be suboptimal for controlling microscopic disease. In a prospective trial, we tested whether image-guided intensity-modulated radiation therapy (IMRT) can safely deliver escalated nodal doses while treating the prostate with hypofractionated radiotherapy in 5 Vulgar-Fraction-One-Half weeks. Methods and Materials: Pelvic nodal and prostatic image-guided IMRT was delivered to 53 National Comprehensive Cancer Network (NCCN) high-risk patients to a nodal dose of 56 Gy in 2-Gy fractions with concomitant treatment of the prostate to 70 Gy in 28 fractions of 2.5 Gy, and 50 of 53 patients received androgen deprivation for a median duration of 12 months. Results: The median follow-up time was 25.4 months (range, 4.2-57.2). No early Grade 3 Radiation Therapy Oncology Group or Common Terminology Criteria for Adverse Events v.3.0 genitourinary (GU) or gastrointestinal (GI) toxicities were seen. The cumulative actuarial incidence of Grade 2 early GU toxicity (primarily alpha blocker initiation) was 38%. The rate was 32% for Grade 2 early GI toxicity. None of the dose-volume descriptors correlated with GU toxicity, and only the volume of bowel receiving {>=}30 Gy correlated with early GI toxicity (p = 0.029). Maximum late Grades 1, 2, and 3 GU toxicities were seen in 30%, 25%, and 2% of patients, respectively. Maximum late Grades 1 and 2 GI toxicities were seen in 30% and 8% (rectal bleeding requiring cautery) of patients, respectively. The estimated 3-year biochemical control (nadir + 2) was 81.2 {+-} 6.6%. No patient manifested pelvic nodal failure, whereas 2 experienced paraaortic nodal failure outside the field. The six other clinical failures were distant only. Conclusions: Pelvic IMRT nodal dose escalation to 56 Gy was delivered concurrently with 70 Gy of hypofractionated prostate radiotherapy in a convenient, resource-efficient, and well-tolerated 28-fraction schedule. Pelvic nodal dose

  12. Patterns of practice of regional nodal irradiation in breast cancer: results of the European Organization for Research and Treatment of Cancer (EORTC) NOdal Radiotherapy (NORA) survey

    NARCIS (Netherlands)

    Belkacemi, Y.; Kaidar-Person, O.; Poortmans, P.; Ozsahin, M.; Valli, M.-C.; Russell, N.; Kunkler, I.; Hermans, J.; Kuten, A.; van Tienhoven, G.; Westenberg, H.

    2015-01-01

    Predicting outcome of breast cancer (BC) patients based on sentinel lymph node (SLN) status without axillary lymph node dissection (ALND) is an area of uncertainty. It influences the decision-making for regional nodal irradiation (RNI). The aim of the NORA (NOdal RAdiotherapy) survey was to examine

  13. Late development of colorectal cancer subsequent to pelvic irradiation

    International Nuclear Information System (INIS)

    O'Connor, T.W.; Rombeau, J.L.; Levine, H.S.; Turnbull, R.B. Jr.

    1979-01-01

    Two cases of irradiation-associated carcinoma of the colon are reported and the literature reviewed. The clinical courses and operative difficulties in treating these patients are emphasized. The necessity for life-long follow-up examinations with proctoscopic and barium-enema evaluations in high-risk patients is stressed. Irradiation-associated carcinoma of the colon occurs almost exclusively in women, but should be investigated in patients of either sex who live for long periods after pelvic irradiation

  14. A three-dimensional definition of nodal spaces on the basis of CT images showing enlarged nodes for pelvic radiotherapy

    International Nuclear Information System (INIS)

    Portaluri, Maurizio; Bambace, Santa; Perez, Celeste; Angone, Grazia

    2005-01-01

    Purpose: To demonstrate that margins of each pelvic chain may be derived by verifying the bony and soft tissue structures around abnormal nodes on computed tomography (CT) slices. Methods and Materials: Twenty consecutive patients (16 males, 4 females; mean age, 66 years; range, 43-80 years) with radiologic diagnosis of nodal involvement by histologically proved cervix carcinoma (two), rectum carcinoma (three), prostate carcinoma (four), lymphoma (five), penis carcinoma (one), corpus uteri carcinoma (one), bladder carcinoma (two), cutis tumor (one), and soft-tissue sarcoma (one) were retrospectively reviewed. One hundred CT scans showing 85 enlarged pelvic nodes were reviewed by two radiation oncologists (M.P., S.B.), and two radiologists (C.P., G.A.). Results: The more proximal structures to each enlarged node or group of nodes were thus recorded in a clockwise direction. Conclusion: According to their frequency and visibility, craniocaudal, anterior, lateral, posterior and medial margins of common iliac, external and internal iliac nodal chains, obturator and pudendal nodes, and deep and superficial inguinal nodes were derived from CT observations

  15. Prospective study of nutritional support during pelvic irradiation

    International Nuclear Information System (INIS)

    Kinsella, T.J.; Malcolm, A.W.; Bothe, A. Jr.; Valerio, D.; Blackburn, G.L.

    1981-01-01

    A prospective study of nutritional support during pelvic irradiation was carried out in 32 patients with a primary pelvic malignancy and prior weight loss. Both curative and palliative patients were eligible for the study. Seventeen patients were randomized to receive intravenous hyperalimentation (IVH) and fifteen patients served as controls who were maintained on their regular diet. Patients were stratified by percent body weight loss. Tolerance to therapy was assessed by evaluation of functional status and by using nutritional parameters of body weight change, change in serum protein levels, and response to delayed hypersensitivity skin tests. The curative IVH group tolerated therapy well by both functional and nutritional measurements. All curative IVH patients completed the planned radiation therapy without a treatment break and were fully active following treatment. Patients gained an average of 4.0 kg body weight during irradiation, which was significantly different from the curative control patients. They demonstrated a significant increase in serum transferrin reflecting an improvement in visceral protein. In addition, all showed a positive response to delayed hypersensitivity skin tests at the completion of irradiation. The palliative IVH patients often did poorly because of progression of disease and demonstrated only an elevation of serum transferrin during treatment. The results in the curative IVH group suggest a potential adjunctive role for intravenous hyperalimentation in the malnourished cancer patient undergoing pelvic irradiation. Clearly, further study of nutritional support during pelvic irradiation is needed using curative patients with a single tumor type and significant prior weight loss

  16. Can pelvic node dissection at radical prostatectomy influence the nodal recurrence at salvage lymphadenectomy for prostate cancer?

    Directory of Open Access Journals (Sweden)

    Arjun Sivaraman

    2018-03-01

    Full Text Available Purpose: To verify the quality of pelvic lymph node dissection (PLND performed at radical prostatectomy (RP and its impact on nodal recurrence in patients undergoing salvage lymph node dissection (sLND. Materials and Methods: Retrospective review of 48 patients who underwent sLND for presumed nodal recurrence, to describe the PLND characteristics at RP and correlate the anatomical sites and number of suspicious nodes reported in radiological imaging and final pathology of sLND. Results: Overall, at RP, 8 (16.7% did not undergo PLND, 32 (66.7% and 8 (16.7% received a “limited” (between external iliac vein and obturator nerve and an “extended” (external iliac, hypogastric, and obturator dissection, respectively. Median nodes removed during limited and extended dissection were 2 and 24, respectively. At sLND, the mean age was 61.3 years and median prostate specific antigen (PSA was 1.07 ng/mL. Median nodes removed at sLND were 17 with a median of 2 positive nodes. Recurrent nodes were identified within the template of an extended PLND in 62.5%, 50.0% and 12.5% patients, respectively, following prior no, limited and extended dissection at RP. Recurrence outside the expected lymphatic drainage pathway was noted in 37.5% patients with prior extended dissection at RP. There was a correlation between imaging and pathology specimen in 83% for node location and 58.3% for number of anatomical sites involved. Conclusions: In prostate cancer patients undergoing sLND, most had inadequate PLND at the original RP. Pattern of nodal recurrence may be influenced by the prior dissection and pre sLND imaging appears to underestimate the nodal recurrence.

  17. Can pelvic node dissection at radical prostatectomy influence the nodal recurrence at salvage lymphadenectomy for prostate cancer?

    Science.gov (United States)

    Sivaraman, Arjun; Benfante, Nicole; Touijer, Karim; Coleman, Jonathan; Scardino, Peter; Laudone, Vincent; Eastham, James

    2018-03-01

    To verify the quality of pelvic lymph node dissection (PLND) performed at radical prostatectomy (RP) and its impact on nodal recurrence in patients undergoing salvage lymph node dissection (sLND). Retrospective review of 48 patients who underwent sLND for presumed nodal recurrence, to describe the PLND characteristics at RP and correlate the anatomical sites and number of suspicious nodes reported in radiological imaging and final pathology of sLND. Overall, at RP, 8 (16.7%) did not undergo PLND, 32 (66.7%) and 8 (16.7%) received a "limited" (between external iliac vein and obturator nerve) and an "extended" (external iliac, hypogastric, and obturator) dissection, respectively. Median nodes removed during limited and extended dissection were 2 and 24, respectively. At sLND, the mean age was 61.3 years and median prostate specific antigen (PSA) was 1.07 ng/mL. Median nodes removed at sLND were 17 with a median of 2 positive nodes. Recurrent nodes were identified within the template of an extended PLND in 62.5%, 50.0% and 12.5% patients, respectively, following prior no, limited and extended dissection at RP. Recurrence outside the expected lymphatic drainage pathway was noted in 37.5% patients with prior extended dissection at RP. There was a correlation between imaging and pathology specimen in 83% for node location and 58.3% for number of anatomical sites involved. In prostate cancer patients undergoing sLND, most had inadequate PLND at the original RP. Pattern of nodal recurrence may be influenced by the prior dissection and pre sLND imaging appears to underestimate the nodal recurrence.

  18. Spontaneous occurrence of synergistic bacterial gangrene following external pelvic irradiation

    International Nuclear Information System (INIS)

    Husseinzadeh, N.; Nahhas, W.A.; Manders, E.K.; Whitney, C.W.; Mortel, R.

    1984-01-01

    A case of spontaneous synergistic bacterial gangrene occurring after external pelvic irradiation is presented in a 25-year-old woman with invasive cervical cancer. Treatment consisted of aggressive antibiotic therapy and extensive excision and debridement followed by split-thickness skin grafting. Both recovery and cosmetic results were satisfactory. The pathophysiology, predisposing factors, and treatment modalities are presented

  19. Patterns of failure after the reduced volume approach for elective nodal irradiation in nasopharyngeal carcinoma.

    Science.gov (United States)

    Seol, Ki Ho; Lee, Jeong Eun

    2016-03-01

    To evaluate the patterns of nodal failure after radiotherapy (RT) with the reduced volume approach for elective neck nodal irradiation (ENI) in nasopharyngeal carcinoma (NPC). Fifty-six NPC patients who underwent definitive chemoradiotherapy with the reduced volume approach for ENI were reviewed. The ENI included retropharyngeal and level II lymph nodes, and only encompassed the echelon inferior to the involved level to eliminate the entire neck irradiation. Patients received either moderate hypofractionated intensity-modulated RT for a total of 72.6 Gy (49.5 Gy to elective nodal areas) or a conventional fractionated three-dimensional conformal RT for a total of 68.4-72 Gy (39.6-45 Gy to elective nodal areas). Patterns of failure, locoregional control, and survival were analyzed. The median follow-up was 38 months (range, 3 to 80 months). The out-of-field nodal failure when omitting ENI was none. Three patients developed neck recurrences (one in-field recurrence in the 72.6 Gy irradiated nodal area and two in the elective irradiated region of 39.6 Gy). Overall disease failure at any site developed in 11 patients (19.6%). Among these, there were six local failures (10.7%), three regional failures (5.4%), and five distant metastases (8.9%). The 3-year locoregional control rate was 87.1%, and the distant failure-free rate was 90.4%; disease-free survival and overall survival at 3 years was 80% and 86.8%, respectively. No patient developed nodal failure in the omitted ENI site. Our investigation has demonstrated that the reduced volume approach for ENI appears to be a safe treatment approach in NPC.

  20. Patterns of failure after the reduced volume approach for elective nodal irradiation in nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Seol, Ki Ho; Lee, Jeong Eun [Dept. of Radiation Oncology, Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2016-03-15

    To evaluate the patterns of nodal failure after radiotherapy (RT) with the reduced volume approach for elective neck nodal irradiation (ENI) in nasopharyngeal carcinoma (NPC). Fifty-six NPC patients who underwent definitive chemoradiotherapy with the reduced volume approach for ENI were reviewed. The ENI included retropharyngeal and level II lymph nodes, and only encompassed the echelon inferior to the involved level to eliminate the entire neck irradiation. Patients received either moderate hypofractionated intensity-modulated RT for a total of 72.6 Gy (49.5 Gy to elective nodal areas) or a conventional fractionated three-dimensional conformal RT for a total of 68.4-72 Gy (39.6-45 Gy to elective nodal areas). Patterns of failure, locoregional control, and survival were analyzed. The median follow-up was 38 months (range, 3 to 80 months). The out-of-field nodal failure when omitting ENI was none. Three patients developed neck recurrences (one in-field recurrence in the 72.6 Gy irradiated nodal area and two in the elective irradiated region of 39.6 Gy). Overall disease failure at any site developed in 11 patients (19.6%). Among these, there were six local failures (10.7%), three regional failures (5.4%), and five distant metastases (8.9%). The 3-year locoregional control rate was 87.1%, and the distant failure-free rate was 90.4%; disease-free survival and overall survival at 3 years was 80% and 86.8%, respectively. No patient developed nodal failure in the omitted ENI site. Our investigation has demonstrated that the reduced volume approach for ENI appears to be a safe treatment approach in NPC.

  1. Patterns of failure after the reduced volume approach for elective nodal irradiation in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Seol, Ki Ho; Lee, Jeong Eun

    2016-01-01

    To evaluate the patterns of nodal failure after radiotherapy (RT) with the reduced volume approach for elective neck nodal irradiation (ENI) in nasopharyngeal carcinoma (NPC). Fifty-six NPC patients who underwent definitive chemoradiotherapy with the reduced volume approach for ENI were reviewed. The ENI included retropharyngeal and level II lymph nodes, and only encompassed the echelon inferior to the involved level to eliminate the entire neck irradiation. Patients received either moderate hypofractionated intensity-modulated RT for a total of 72.6 Gy (49.5 Gy to elective nodal areas) or a conventional fractionated three-dimensional conformal RT for a total of 68.4-72 Gy (39.6-45 Gy to elective nodal areas). Patterns of failure, locoregional control, and survival were analyzed. The median follow-up was 38 months (range, 3 to 80 months). The out-of-field nodal failure when omitting ENI was none. Three patients developed neck recurrences (one in-field recurrence in the 72.6 Gy irradiated nodal area and two in the elective irradiated region of 39.6 Gy). Overall disease failure at any site developed in 11 patients (19.6%). Among these, there were six local failures (10.7%), three regional failures (5.4%), and five distant metastases (8.9%). The 3-year locoregional control rate was 87.1%, and the distant failure-free rate was 90.4%; disease-free survival and overall survival at 3 years was 80% and 86.8%, respectively. No patient developed nodal failure in the omitted ENI site. Our investigation has demonstrated that the reduced volume approach for ENI appears to be a safe treatment approach in NPC

  2. Pelvic nodal dose escalation with prostate hypofractionation using conformal avoidance defined (H-CAD) intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Hong, Theodore S.; Tome, Wolfgang A.; Jaradat, Hazim; Raisbeck, Bridget M.; Ritter, Mark A.

    2006-01-01

    The management of prostate cancer patients with a significant risk of pelvic lymph node involvement is controversial. Both whole pelvis radiotherapy and dose escalation to the prostate have been linked to improved outcome in such patients, but it is unclear whether conventional whole pelvis doses of only 45-50 Gy are optimal for ultimate nodal control. The purpose of this study is to examine the dosimetric and clinical feasibility of combining prostate dose escalation via hypofractionation with conformal avoidance-based IMRT (H-CAD) dose escalation to the pelvic lymph nodes. One conformal avoidance and one conventional plan were generated for each of eight patients. Conformal avoidance-based IMRT plans were generated that specifically excluded bowel, rectum, and bladder. The prostate and lower seminal vesicles (PTV 70) were planned to receive 70 Gy in 2.5 Gy/fraction while the pelvic lymph nodes (PTV 56) were to concurrently receive 56 Gy in 2 Gy/fraction. The volume of small bowel receiving >45 Gy was restricted to 300 ml or less. These conformal avoidance plans were delivered using helical tomotherapy or LINAC-based IMRT with daily imaging localization. All patients received neoadjuvant and concurrent androgen deprivation with a planned total of two years. The conventional, sequential plans created for comparison purposes for all patients consisted of a conventional 4-field pelvic box prescribed to 50.4 Gy (1.8 Gy/fraction) followed by an IMRT boost to the prostate of 25.2 Gy (1.8 Gy/fraction) yielding a final prostate dose of 75.6 Gy. For all plans, the prescription dose was to cover the target structure. Equivalent uniform dose (EUD) analyses were performed on all targets and dose-volume histograms (DVH) were displayed in terms of both physical and normalized total dose (NTD), i.e. dose in 2 Gy fraction equivalents. H-CAD IMRT plans were created for and delivered to all eight patients. Analysis of the H-CAD plans demonstrates prescription dose coverage of >95

  3. Variation in the Definition of Clinical Target Volumes for Pelvic Nodal Conformal Radiation Therapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Lawton, Colleen A.F.; Michalski, Jeff; El-Naqa, Issam; Kuban, Deborah; Lee, W. Robert; Rosenthal, Seth A.; Zietman, Anthony; Sandler, Howard; Shipley, William; Ritter, Mark; Valicenti, Richard; Catton, Charles; Roach, Mack; Pisansky, Thomas M.; Seider, Michael

    2009-01-01

    Purpose: We conducted a comparative study of clinical target volume (CTV) definition of pelvic lymph nodes by multiple genitourinary (GU) radiation oncologists looking at the levels of discrepancies amongst this group. Methods and Materials: Pelvic computed tomography (CT) scans from 2 men were distributed to 14 Radiation Therapy Oncology Group GU radiation oncologists with instructions to define CTVs for the iliac and presacral lymph nodes. The CT data with contours were then returned for analysis. In addition, a questionnaire was completed that described the physicians' method for target volume definition. Results: Significant variation in the definition of the iliac and presacral CTVs was seen among the physicians. The minimum, maximum, mean (SD) iliac volumes (mL) were 81.8, 876.6, 337.6 ± 203 for case 1 and 60.3, 627.7, 251.8 ± 159.3 for case 2. The volume of 100% agreement was 30.6 and 17.4 for case 1 and 2 and the volume of the union of all contours was 1,012.0 and 807.4 for case 1 and 2, respectively. The overall agreement was judged to be moderate in both cases (kappa = 0.53 (p < 0.0001) and kappa = 0.48 (p < 0.0001). There was no volume of 100% agreement for either of the two presacral volumes. These variations were confirmed in the responses to the associated questionnaire. Conclusions: Significant disagreement exists in the definition of the CTV for pelvic nodal radiation therapy among GU radiation oncology specialists. A consensus needs to be developed so as to accurately assess the merit and safety of such treatment.

  4. [Does nodal irradiation (clavicular and internal mammary chains) increase the toxicity of adjuvant breast radiotherapy?].

    Science.gov (United States)

    Riou, O; Bourgier, C; Fenoglietto, P; Azria, D

    2015-06-01

    Treatment volume is a major risk factor of radiation-induced toxicity. As nodal irradiation increases treatment volume, radiation toxicity should be greater. Nevertheless, scientific randomised data do not support this fact. However, a radiation-induced toxicity is possible outside tangential fields in the nodal volumes not related to breast-only treatment. Treatment should not be adapted only to the disease but personalized to the individual risk of toxicity for each patient. Copyright © 2015 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  5. Nodal Clearance Rate and Long-Term Efficacy of Individualized Sentinel Node–Based Pelvic Intensity Modulated Radiation Therapy for High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Müller, Arndt-Christian, E-mail: arndt-christian.mueller@med.uni-tuebingen.de [Department of Radiation Oncology, Eberhard Karls University, Tübingen (Germany); Eckert, Franziska; Paulsen, Frank; Zips, Daniel [Department of Radiation Oncology, Eberhard Karls University, Tübingen (Germany); Stenzl, Arnulf; Schilling, David [Department of Urology, Eberhard Karls University, Tübingen (Germany); Alber, Markus [Department of Oncology, Aarhus University, Aarhus (Denmark); Bares, Roland [Department of Nuclear Medicine and Clinical Molecular Imaging, Eberhard Karls University, Tübingen (Germany); Martus, Peter [Institute for Clinical Epidemiology and Applied Biometry, Eberhard Karls University, Tübingen (Germany); Weckermann, Dorothea [Department of Urology, Klinikum Augsburg, Augsburg (Germany); Belka, Claus; Ganswindt, Ute [Department of Radiation Oncology, Ludwig-Maximilians-University, Munich (Germany)

    2016-02-01

    Purpose: To assess the efficacy of individual sentinel node (SN)-guided pelvic intensity modulated radiation therapy (IMRT) by determining nodal clearance rate [(n expected nodal involvement − n observed regional recurrences)/n expected nodal involvement] in comparison with surgically staged patients. Methods and Materials: Data on 475 high-risk prostate cancer patients were examined. Sixty-one consecutive patients received pelvic SN-based IMRT (5 × 1.8 Gy/wk to 50.4 Gy [pelvic nodes + individual SN] and an integrated boost with 5 × 2.0 Gy/wk to 70.0 Gy to prostate + [base of] seminal vesicles) and neo-/adjuvant long-term androgen deprivation therapy; 414 patients after SN–pelvic lymph node dissection were used to calculate the expected nodal involvement rate for the radiation therapy sample. Biochemical control and overall survival were estimated for the SN-IMRT patients using the Kaplan-Meier method. The expected frequency of nodal involvement in the radiation therapy group was estimated by imputing frequencies of node-positive patients in the surgical sample to the pattern of Gleason, prostate-specific antigen, and T category in the radiation therapy sample. Results: After a median follow-up of 61 months, 5-year OS after SN-guided IMRT reached 84.4%. Biochemical control according to the Phoenix definition was 73.8%. The nodal clearance rate of SN-IMRT reached 94%. Retrospective follow-up evaluation is the main limitation. Conclusions: Radiation treatment of pelvic nodes individualized by inclusion of SNs is an effective regional treatment modality in high-risk prostate cancer patients. The pattern of relapse indicates that the SN-based target volume concept correctly covers individual pelvic nodes. Thus, this SN-based approach justifies further evaluation, including current dose-escalation strategies to the prostate in a larger prospective series.

  6. Comparison of treatment outcomes between involved-field and elective nodal irradiation in limited-stage small cell lung cancer

    International Nuclear Information System (INIS)

    Han, Tae-Jin; Kim, Hak-Jae; Wu, Hong-Gyun; Heo, Dae-Seog; Kim, Young-Whan; Lee, Se-Hoon

    2012-01-01

    The present study was performed to assess the usefulness of involved-field irradiation and the impact of 18 F-fluorodeoxyglucose-positron emission tomography-based staging on treatment outcomes in limited-stage small cell lung cancer. Eighty patients who received definitive chemoradiotherapy for limited-stage small cell lung cancer were retrospectively analyzed. Fifty patients were treated with involved-field irradiation, which means that the radiotherapy portal includes only clinically identifiable tumors. The other 30 patients were irradiated with a comprehensive portal, including uninvolved mediastinal and/or supraclavicular lymph nodes, so-called elective nodal irradiation. No significant difference was seen in clinical factors between the two groups. At a median follow-up of 27 months (range, 5-75 months), no significant differences were observed in 3 year overall survival (44.6 vs. 54.1%, P=0.220) and 3 year progression-free survival (24.4 vs. 42.8%, P=0.133) between the involved-field irradiation group and the elective nodal irradiation group, respectively. For patients who did not undergo positron emission tomography scans, 3 year overall survival (29.3 vs. 56.3%, P=0.022) and 3 year progression-free survival (11.0 vs. 50.0%, P=0.040) were significantly longer in the elective nodal irradiation group. Crude incidences of isolated nodal failure were 6.0% in the involved-field irradiation group and 0% in the elective nodal irradiation group, respectively. All isolated nodal failures were developed in patients who had not undergone positron emission tomography scans in their initial work-ups. If patients did not undergo positron emission tomography-based staging, the omission of elective nodal irradiation resulted in impaired survival outcomes and raised the risk of isolated nodal failure. Therefore, involved-field irradiation for limited-stage small cell lung cancer might be reasonable only with positron emission tomography scan implementation. (author)

  7. Exclusion of elective nodal irradiation is associated with minimal elective nodal failure in non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Cox James D

    2009-01-01

    Full Text Available Abstract Background Controversy still exists regarding the long-term outcome of patients whose uninvolved lymph node stations are not prophylactically irradiated for non-small cell lung cancer (NSCLC treated with definitive radiotherapy. To determine the frequency of elective nodal failure (ENF and in-field failure (IFF, we examined a large cohort of patients with NSCLC staged with positron emission tomography (PET/computed tomography (CT and treated with 3-dimensional conformal radiotherapy (3D-CRT that excluded uninvolved lymph node stations. Methods We retrospectively reviewed the records of 115 patients with non-small cell lung cancer treated at our institution with definitive radiation therapy with or without concurrent chemotherapy (CHT. All patients were treated with 3D-CRT, including nodal regions determined by CT or PET to be disease involved. Concurrent platinum-based CHT was administered for locally advanced disease. Patients were analyzed in follow-up for survival, local regional recurrence, and distant metastases (DM. Results The median follow-up time was 18 months (3 to 44 months among all patients and 27 months (6 to 44 months among survivors. The median overall survival, 2-year actuarial overall survival and disease-free survival were 19 months, 38%, and 28%, respectively. The majority of patients died from DM, the overall rate of which was 36%. Of the 31 patients with local regional failure, 26 (22.6% had IFF, 5 (4.3% had ENF and 2 (1.7% had isolated ENF. For 88 patients with stage IIIA/B, the frequencies of IFF, any ENF, isolated ENF, and DM were 23 (26%, 3 (9%, 1 (1.1% and 36 (40.9%, respectively. The comparable rates for the 22 patients with early stage node-negative disease (stage IA/IB were 3 (13.6%, 1(4.5%, 0 (0%, and 5 (22.7%, respectively. Conclusion We observed only a 4.3% recurrence of any ENF and a 1.7% recurrence of isolated ENF in patients with NSCLC treated with definitive 3D-CRT without prophylactic irradiation of

  8. Exclusion of elective nodal irradiation is associated with minimal elective nodal failure in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Sulman, Erik P; Komaki, Ritsuko; Klopp, Ann H; Cox, James D; Chang, Joe Y

    2009-01-01

    Controversy still exists regarding the long-term outcome of patients whose uninvolved lymph node stations are not prophylactically irradiated for non-small cell lung cancer (NSCLC) treated with definitive radiotherapy. To determine the frequency of elective nodal failure (ENF) and in-field failure (IFF), we examined a large cohort of patients with NSCLC staged with positron emission tomography (PET)/computed tomography (CT) and treated with 3-dimensional conformal radiotherapy (3D-CRT) that excluded uninvolved lymph node stations. We retrospectively reviewed the records of 115 patients with non-small cell lung cancer treated at our institution with definitive radiation therapy with or without concurrent chemotherapy (CHT). All patients were treated with 3D-CRT, including nodal regions determined by CT or PET to be disease involved. Concurrent platinum-based CHT was administered for locally advanced disease. Patients were analyzed in follow-up for survival, local regional recurrence, and distant metastases (DM). The median follow-up time was 18 months (3 to 44 months) among all patients and 27 months (6 to 44 months) among survivors. The median overall survival, 2-year actuarial overall survival and disease-free survival were 19 months, 38%, and 28%, respectively. The majority of patients died from DM, the overall rate of which was 36%. Of the 31 patients with local regional failure, 26 (22.6%) had IFF, 5 (4.3%) had ENF and 2 (1.7%) had isolated ENF. For 88 patients with stage IIIA/B, the frequencies of IFF, any ENF, isolated ENF, and DM were 23 (26%), 3 (9%), 1 (1.1%) and 36 (40.9%), respectively. The comparable rates for the 22 patients with early stage node-negative disease (stage IA/IB) were 3 (13.6%), 1(4.5%), 0 (0%), and 5 (22.7%), respectively. We observed only a 4.3% recurrence of any ENF and a 1.7% recurrence of isolated ENF in patients with NSCLC treated with definitive 3D-CRT without prophylactic irradiation of uninvolved lymph node stations. Thus

  9. Radiotherapy for esthesioneuroblastoma: is elective nodal irradiation warranted in the multimodality treatment approach?

    Science.gov (United States)

    Noh, O Kyu; Lee, Sang-wook; Yoon, Sang Min; Kim, Sung Bae; Kim, Sang Yoon; Kim, Chang Jin; Jo, Kyung Ja; Choi, Eun Kyung; Song, Si Yeol; Kim, Jong Hoon; Ahn, Seung Do

    2011-02-01

    The role of elective nodal irradiation (ENI) in radiotherapy for esthesioneuroblastoma (ENB) has not been clearly defined. We analyzed treatment outcomes of patients with ENB and the frequency of cervical nodal failure in the absence of ENI. Between August 1996 and December 2007, we consulted with 19 patients with ENB regarding radiotherapy. Initial treatment consisted of surgery alone in 2 patients; surgery and postoperative radiotherapy in 4; surgery and adjuvant chemotherapy in 1; surgery, postoperative radiotherapy, and chemotherapy in 3; and chemotherapy followed by radiotherapy or concurrent chemoradiotherapy in 5. Five patients did not receive planned radiotherapy because of disease progression. Including 2 patients who received salvage radiotherapy, 14 patients were treated with radiotherapy. Elective nodal irradiation was performed in 4 patients with high-risk factors, including 3 with cervical lymph node metastasis at presentation. Fourteen patients were analyzable, with a median follow-up of 27 months (range, 7-64 months). The overall 3-year survival rate was 73.4%. Local failure occurred in 3 patients (21.4%), regional cervical failure in 3 (21.4%), and distant failure in 2 (14.3%). No cervical nodal failure occurred in patients treated with combined systemic chemotherapy regardless of ENI. Three cervical failures occurred in the 4 patients treated with ENI or neck dissection (75%), none of whom received systemic chemotherapy. ENI during radiotherapy for ENB seems to play a limited role in preventing cervical nodal failure. Omitting ENI may be an option if patients are treated with a combination of radiotherapy and chemotherapy. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Radiotherapy for Esthesioneuroblastoma: Is Elective Nodal Irradiation Warranted in the Multimodality Treatment Approach?

    International Nuclear Information System (INIS)

    Noh, O Kyu; Lee, Sang-wook; Yoon, Sang Min; Kim, Sung Bae; Kim, Sang Yoon; Kim, Chang Jin; Jo, Kyung Ja; Choi, Eun Kyung; Song, Si Yeol; Kim, Jong Hoon; Ahn, Seung Do

    2011-01-01

    Purpose: The role of elective nodal irradiation (ENI) in radiotherapy for esthesioneuroblastoma (ENB) has not been clearly defined. We analyzed treatment outcomes of patients with ENB and the frequency of cervical nodal failure in the absence of ENI. Methods and Materials: Between August 1996 and December 2007, we consulted with 19 patients with ENB regarding radiotherapy. Initial treatment consisted of surgery alone in 2 patients; surgery and postoperative radiotherapy in 4; surgery and adjuvant chemotherapy in 1; surgery, postoperative radiotherapy, and chemotherapy in 3; and chemotherapy followed by radiotherapy or concurrent chemoradiotherapy in 5. Five patients did not receive planned radiotherapy because of disease progression. Including 2 patients who received salvage radiotherapy, 14 patients were treated with radiotherapy. Elective nodal irradiation was performed in 4 patients with high-risk factors, including 3 with cervical lymph node metastasis at presentation. Results: Fourteen patients were analyzable, with a median follow-up of 27 months (range, 7-64 months). The overall 3-year survival rate was 73.4%. Local failure occurred in 3 patients (21.4%), regional cervical failure in 3 (21.4%), and distant failure in 2 (14.3%). No cervical nodal failure occurred in patients treated with combined systemic chemotherapy regardless of ENI. Three cervical failures occurred in the 4 patients treated with ENI or neck dissection (75%), none of whom received systemic chemotherapy. Conclusions: ENI during radiotherapy for ENB seems to play a limited role in preventing cervical nodal failure. Omitting ENI may be an option if patients are treated with a combination of radiotherapy and chemotherapy.

  11. The role of elective nodal irradiation for esthesioneuroblastoma patients with clinically negative neck.

    Science.gov (United States)

    Jiang, Wen; Mohamed, Abdallah S R; Fuller, Clifton David; Kim, Betty Y S; Tang, Chad; Gunn, G Brandon; Hanna, Ehab Y; Frank, Steven J; Su, Shirley Y; Diaz, Eduardo; Kupferman, Michael E; Beadle, Beth M; Morrison, William H; Skinner, Heath; Lai, Stephen Y; El-Naggar, Adel K; DeMonte, Franco; Rosenthal, David I; Garden, Adam S; Phan, Jack

    2016-01-01

    Although adjuvant radiation to the tumor bed has been reported to improve the clinic outcomes of esthesioneuroblastoma (ENB) patients, the role of elective neck irradiation (ENI) in clinically node-negative (N0) patients remains controversial. Here, we evaluated the effects of ENI on neck nodal relapse risk in ENB patients treated with radiation therapy as a component of multimodality treatment. Seventy-one N0 ENB patients irradiated at the University of Texas MD Anderson Cancer Center between 1970 and 2013 were identified. ENI was performed on 22 of these patients (31%). Survival analysis was performed with focus on comparative outcomes of those patients who did and did not receive ENI. The median follow-up time for our cohort is 80.8 months (range, 6-350 months). Among N0 patients, 13 (18.3%) developed neck nodal relapses, with a median time to progression of 62.5 months. None of these 13 patients received prophylactic neck irradiation. ENI was associated with significantly improved regional nodal control at 5 years (regional control rate of 100% for ENI vs 82%, P ENI developed isolated neck recurrences. All had further treatment for their neck disease, including neck dissection (n = 10), radiation (n = 10), or chemotherapy (n = 5). Six of these 11 patients (54.5%) demonstrated no evidence of further recurrence with a median follow-up of 55.5 months. ENI significantly reduces the risk of cervical nodal recurrence in ENB patients with clinically N0 neck, but this did not translate to a survival benefit. Multimodality treatment for isolated neck recurrence provides a reasonable salvage rate. The greatest benefit for ENI appeared to be among younger patients who presented with Kadish C disease. Further studies are needed to confirm these findings. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  12. The role of elective-nodal irradiation for esthesioneuroblastoma patients with clinically negative neck

    Science.gov (United States)

    Jiang, Wen; Mohamed, Abdallah Sherif; Fuller, Clifton David; Kim, Betty Y.S.; Tang, Chad; Gunn, G. Brandon; Hanna, Ehab Y.; Frank, Steven J.; Su, Shirley Y.; Diaz, Eduardo; Kupferman, Michael E.; Beadle, Beth M.; Morrison, William H.; Skinner, Heath; Lai, Stephen Y.; El-Naggar, Adel K.; DeMonte, Franco; Rosenthal, David I.; Garden, Adam S.; Phan, Jack

    2017-01-01

    Purpose Although adjuvant radiation to the tumor bed has been reported to improve the clinic outcomes of esthesioneuroblastoma (ENB) patients, the role of elective neck irradiation (ENI) in clinically node negative (N0) patients remains controversial. Here, we evaluated the effects of ENI on neck nodal relapse risk in ENB patients treated with radiotherapy as a component of multi-modality treatment. Methods and Materials Seventy-one N0 ENB patients irradiated at XXXXXXXXX between 1970 and 2013 were identified. ENI was performed on 22 of these patients (31%). Survival analysis was performed with focus on comparative outcomes of those patients who did and did not receive ENI. Results The median follow up time for our cohort is 80.8 months (range 6 – 350 month). Among N0 patients, 13 (18.3%) developed neck nodal relapses, with a median time to progression of 62.5 months. None of these 13 patients received prophylactic neck irradiation. ENI was associated with significantly improved regional nodal control at 5-year (regional control rate of 100% for ENI vs 82%, p ENI developed isolated neck recurrences. All had further treatment for their neck disease, including neck dissection (n=10), radiation (n=10), or chemotherapy (n=5). Six of these 11 patients (54.5%) demonstrated no evidence of further recurrence with a median follow up of 55.5 month. Conclusion ENI significantly reduces the risk of cervical nodal recurrence in ENB patients with clinically N0 neck but this did not translate to a survival benefit. Multimodality treatment for isolated neck recurrence provides a reasonable salvage rate. The greatest benefit for ENI appeared to be among younger patients who presented with Kadish C disease. Further studies are needed to confirm these findings. PMID:26979544

  13. Hypofractionated Prostate Radiotherapy with or without Conventionally Fractionated Nodal Irradiation: Clinical Toxicity Observations and Retrospective Daily Dosimetry.

    Science.gov (United States)

    McDonald, Andrew M; Bishop, Justin M; Jacob, Rojymon; Dobelbower, Michael C; Kim, Robert Y; Yang, Eddy S; Smith, Heather; Wu, Xingen; Fiveash, John B

    2012-01-01

    Purpose. To evaluate toxicity associated with the addition of elective nodal irradiation (ENI) to a hypofractionated regimen for the treatment of prostate cancer. Methods and Materials. Fifty-seven patients received pelvic image-guided IMRT to 50.4 Gy in 28 fractions with a hypofractionated simultaneous boost to the prostate to 70 Gy. Thirty-one patients received prostate-only treatment to 70 Gy in 28 fractions. Results. Median followup was 41.1 months. Early grade ≥2 urinary toxicity rates were 49% (28 of 57) for patients receiving ENI and 58% (18 of 31) for those not (P = 0.61). Early grade ≥2 rectal toxicity rates were 40% (23 of 57) and 23% (7 of 31), respectively (P = 0.09). The addition of ENI resulted in a 21% actuarial rate of late grade ≥2 rectal toxicity at 4 years, compared to 0% for patients treated to the prostate only (P = 0.02). Retrospective daily dosimetry of patients experiencing late rectal toxicity revealed an average increase of 2.67% of the rectal volume receiving 70 Gy compared to the original plan. Conclusions. The addition of ENI resulted in an increased risk of late rectal toxicity. Grade ≥2 late rectal toxicity was associated with worse daily rectal dosimetry compared to the treatment plan.

  14. Risk factors related to interfractional variation in whole pelvic irradiation for locally advanced pelvic malignancies

    International Nuclear Information System (INIS)

    Yoon, W.S.; Yang, D.S.; Lee, J.A.; Lee, S.; Park, Y.J.; Kim, C.Y.

    2012-01-01

    Purpose: The goal of the present study was to demonstrate risk factors affecting the interfractional variation in whole pelvic irradiation. Patients and methods: Daily image acquisitions of 101 patients with locally advanced pelvic malignancy were undertaken using a kilo-voltage orthogonal on-board imager. The baseline deviation (the shift between the initial treatment and each fraction; Value Base ) and day-to-day variation (the shift between the previous treatment and each fraction; Value DD ) were measured. The standard deviations (SD) along the x- (right-left), y- (cranial-caudal), and z- (anterior-posterior) axes (SD[x], SD[y], and SD[z], respectively), the 3D vector of the SD (SD[3D]), and the mean of 3D shift (mean[3D]) were calculated in each patient. Various clinical factors, lumbar pelvic balance and rotation, and the shift of 5 consecutive fractions from the initial treatment (Value 5Fx ) were investigated as risk factors. Results: The prone set-up showed a larger mean Base [3D] than in the supine position (p =0.063). A body mass index (BMI) ≥ 30 kg/m 2 resulted in the largest mean DD [3D] (p = 0.078) and SD DD [3D] (p = 0.058). All the SD 5Fx along the x-, y-, and z-axes had moderate linear relationships with SD Base and SD DD (p 5Fx [3D] also had a moderate linear relationship with the mean Base [3D], mean DD [3D], SD Base [3D], and SD DD [3D] (p 5Fx had the same significant relationship with SD Base and SD DD (p 2 was associated with the largest SD DD [x] (p = 0.003). Conclusion: Close surveillance through high-quality and frequent image guidance is recommended for patients with extensive variations of the initial five consecutive fractions or obesity. (orig.)

  15. Reconstructive surgery for the complications of pelvic irradiation

    International Nuclear Information System (INIS)

    Bricker, E.M.; Johnston, W.D.; Kraybill, W.G.; Lopez, M.J.

    1984-01-01

    Severe damage to the pelvic viscera is a complication of irradiation therapy that, unfortunately, cannot always be avoided. Resulting rectal and rectocolonic strictures, rectovaginal fistulas, and shortening and stenosis of the vagina present very difficult problems that frequently require a colostomy for relief and may permanently impair sexual function. The authors present a new approach to correction of these unfortunate lesions based on the use of proximal nonirradiated colon which serves as a vascular pedicle graft to correct the defect without a complicated and massive resection. Twenty-two such operations have been done with 19 satisfactory to excellent results and two total failures (one death from small bowel complications). All patterns and combinations of irradiation injury have been found amenable to this technique of repair. These have included both web and linear strictures with and without fistulas. In half of the patients, it was possible to make use of normal colon bypassed by a prior colostomy. Normal nonirradiated colon with good blood supply will heal satisfactorily to irradiated colon or rectum, thus making excision of all the irradiated tissue unnecessary. The results of this surgical approach have thus far been gratifying and warrant further trials for these distressing injuries

  16. Assessing the risk of pelvic and para-aortic nodal involvement in apparent early-stage ovarian cancer: A predictors- and nomogram-based analyses.

    Science.gov (United States)

    Bogani, Giorgio; Tagliabue, Elena; Ditto, Antonino; Signorelli, Mauro; Martinelli, Fabio; Casarin, Jvan; Chiappa, Valentina; Dondi, Giulia; Leone Roberti Maggiore, Umberto; Scaffa, Cono; Borghi, Chiara; Montanelli, Luca; Lorusso, Domenica; Raspagliesi, Francesco

    2017-10-01

    To estimate the prevalence of lymph node involvement in early-stage epithelial ovarian cancer in order to assess the prognostic value of lymph node dissection. Data of consecutive patients undergoing staging for early-stage epithelial ovarian cancer were retrospectively evaluated. Logistic regression and a nomogram-based analysis were used to assess the risk of lymph node involvement. Overall, 290 patients were included. All patients had lymph node dissection including pelvic and para-aortic lymphadenectomy. Forty-two (14.5%) patients were upstaged due to lymph node metastatic disease. Pelvic and para-aortic nodal metastases were observed in 22 (7.6%) and 42 (14.5%) patients. Lymph node involvement was observed in 18/95 (18.9%), 1/37 (2.7%), 4/29 (13.8%), 11/63 (17.4%), 3/41 (7.3%) and 5/24 (20.8%) patients with high-grade serous, low-grade-serous, endometrioid G1, endometrioid G2&3, clear cell and undifferentiated, histology, respectively (p=0.12, Chi-square test). We observed that high-grade serous histology was associated with an increased risk of pelvic node involvement; while, histology rather than low-grade serous and bilateral tumors were independently associated with para-aortic lymph node involvement (p<0.05). Nomograms displaying the risk of nodal involvement in the pelvic and para-aortic areas were built. High-grade serous histology and bilateral tumors are the main characteristics suggesting lymph node positivity. Our data suggested that high-grade serous and bilateral early-stage epithelial ovarian cancer are at high risk of having disease harboring in the lymphatic tissues of both pelvic and para-aortic area. After receiving external validation, our data will help to identify patients deserving comprehensive retroperitoneal staging. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Elective nodal irradiation (ENI) in definitive chemoradiotherapy (CRT) for squamous cell carcinoma of the thoracic esophagus.

    Science.gov (United States)

    Onozawa, Masakatsu; Nihei, Keiji; Ishikura, Satoshi; Minashi, Keiko; Yano, Tomonori; Muto, Manabu; Ohtsu, Atsushi; Ogino, Takashi

    2009-08-01

    There are some reports indicating that prophylactic three-field lymph node dissection for esophageal cancer can lead to improved survival. But the benefit of ENI in CRT for thoracic esophageal cancer remains controversial. The purpose of the present study is to retrospectively evaluate the efficacy of elective nodal irradiation (ENI) in definitive chemoradiotherapy (CRT) for thoracic esophageal cancer. Patients with squamous cell carcinoma (SCC) of the thoracic esophagus newly diagnosed between February 1999 and April 2001 in our institution was recruited from our database. Definitive chemoradiotherapy consisted of two cycles of cisplatin/5FU repeated every 5 weeks, with concurrent radiation therapy of 60 Gy in 30 fractions. Up to 40 Gy radiation therapy was delivered to the cervical, periesophageal, mediastinal and perigastric lymph nodes as ENI. One hundred two patients were included in this analysis, and their characteristics were as follows: median age, 65 years; male/female, 85/17; T1/T2/T3/T4, 16/11/61/14; N0/N1, 48/54; M0/M1, 84/18. The median follow-up period for the surviving patients was 41 months. Sixty patients achieved complete response (CR). After achieving CR, only one (1.0%; 95% CI, 0-5.3%) patient experienced elective nodal failure without any other site of recurrence. In CRT for esophageal SCC, ENI is effective for preventing regional nodal failure. Further evaluation of whether ENI leads to an improved overall survival is needed.

  18. Successful surrogate pregnancy after ovarian transposition, pelvic irradiation and hysterectomy.

    Science.gov (United States)

    Zinger, Michael; Liu, James H; Husseinzadeh, Nader; Thomas, Michael A

    2004-07-01

    Treatment of cervical cancer is often effective but at the cost of the woman's fertility. Ovarian transposition with subsequent oocyte retrieval and surrogate pregnancy can enable these patients to become genetic parents. We present the third reported such case. A 22-year-old woman was diagnosed with bulky, stage IB cervical cancer. Following transposition of both ovaries to the upper abdomen, she underwent pelvic irradiation followed by total abdominal hysterectomy. Eleven years later she presented for assisted reproduction. Two oocytes were retrieved following ovarian stimulation and transcutaneous, abdominal oocyte retrieval. One embryo was transferred to the gestational surrogate, resulting in a single intrauterine pregnancy and successful delivery at term. These procedures can preservefertility while successfully treating cervical cancer.

  19. Risk factors related to interfractional variation in whole pelvic irradiation for locally advanced pelvic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, W.S.; Yang, D.S.; Lee, J.A.; Lee, S.; Park, Y.J.; Kim, C.Y. [Korea Univ. Medical Center, Seoul (Korea, Republic of). Dept. of Radiation Oncology

    2012-05-15

    Purpose: The goal of the present study was to demonstrate risk factors affecting the interfractional variation in whole pelvic irradiation. Patients and methods: Daily image acquisitions of 101 patients with locally advanced pelvic malignancy were undertaken using a kilo-voltage orthogonal on-board imager. The baseline deviation (the shift between the initial treatment and each fraction; Value{sub Base}) and day-to-day variation (the shift between the previous treatment and each fraction; Value{sub DD}) were measured. The standard deviations (SD) along the x- (right-left), y- (cranial-caudal), and z- (anterior-posterior) axes (SD[x], SD[y], and SD[z], respectively), the 3D vector of the SD (SD[3D]), and the mean of 3D shift (mean[3D]) were calculated in each patient. Various clinical factors, lumbar pelvic balance and rotation, and the shift of 5 consecutive fractions from the initial treatment (Value{sub 5Fx}) were investigated as risk factors. Results: The prone set-up showed a larger mean{sub Base}[3D] than in the supine position (p =0.063). A body mass index (BMI) {>=} 30 kg/m{sup 2} resulted in the largest mean{sub DD}[3D] (p = 0.078) and SD{sub DD}[3D] (p = 0.058). All the SD{sub 5Fx} along the x-, y-, and z-axes had moderate linear relationships with SD{sub Base} and SD{sub DD} (p < 0.001). The SD{sub 5Fx}[3D] also had a moderate linear relationship with the mean{sub Base}[3D], mean{sub DD}[3D], SD{sub Base}[3D], and SD{sub DD}[3D] (p < 0.001). In multivariate analysis, the SD{sub 5Fx} had the same significant relationship with SD{sub Base} and SD{sub DD} (p < 0.001). A BMI {>=} 30 kg/m{sup 2} was associated with the largest SD{sub DD}[x] (p = 0.003). Conclusion: Close surveillance through high-quality and frequent image guidance is recommended for patients with extensive variations of the initial five consecutive fractions or obesity. (orig.)

  20. Pelvic Nodal Dosing With Registration to the Prostate: Implications for High-Risk Prostate Cancer Patients Receiving Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Kishan, Amar U.; Lamb, James M.; Jani, Shyam S.; Kang, Jung J.; Steinberg, Michael L.; King, Christopher R.

    2015-01-01

    Purpose: To determine whether image guidance with rigid registration (RR) to intraprostatic markers (IPMs) yields acceptable coverage of the pelvic lymph nodes in the context of a stereotactic body radiation therapy (SBRT) regimen. Methods and Materials: Four to seven kilovoltage cone-beam CTs (CBCTs) from 12 patients with high-risk prostate cancer were analyzed, allowing approximation of an SBRT regimen. The nodal clinical target volume (CTV N ) and bladder were contoured on all kilovoltage CBCTs. The V 100 CTV N , expressed as a ratio to the same parameter on the initial plan, and the magnitude of translational shift between RR to the IPMs versus RR to the pelvic bones, were computed. The ability of a multimodality bladder filling protocol to minimize bladder height variation was assessed in a separate cohort of 4 patients. Results: Sixty-five CBCTs were assessed. The average V 100 CTV N was 92.6%, but for a subset of 3 patients the average was 80.0%, compared with 97.8% for the others (P<.0001). The average overall and superior–inferior axis magnitudes of the bony-to-fiducial translations were significantly larger in the subgroup with suboptimal nodal coverage (8.1 vs 3.9 mm and 5.8 vs 2.4 mm, respectively; P<.0001). Relative bladder height changes were also significantly larger in the subgroup with suboptimal nodal coverage (42.9% vs 18.5%; P<.05). Use of a multimodality bladder-filling protocol minimized bladder height variation (P<.001). Conclusion: A majority of patients had acceptable nodal coverage after RR to IPMs, even when approximating SBRT. However, a subset of patients had suboptimal nodal coverage. These patients had large bony-to-fiducial translations and large variations in bladder height. Nodal coverage should be excellent if the superior–inferior axis bony-to-fiducial translation and the relative bladder height change (both easily measured on CBCT) are kept to a minimum. Implementation of a strict bladder filling protocol may achieve this

  1. Elective nodal irradiation (ENI) in definitive chemoradiotherapy (CRT) for squamous cell carcinoma of the thoracic esophagus

    International Nuclear Information System (INIS)

    Onozawa, Masakatsu; Nihei, Keiji; Ishikura, Satoshi; Minashi, Keiko; Yano, Tomonori; Muto, Manabu; Ohtsu, Atsushi; Ogino, Takashi

    2009-01-01

    Background and purpose: There are some reports indicating that prophylactic three-field lymph node dissection for esophageal cancer can lead to improved survival. But the benefit of ENI in CRT for thoracic esophageal cancer remains controversial. The purpose of the present study is to retrospectively evaluate the efficacy of elective nodal irradiation (ENI) in definitive chemoradiotherapy (CRT) for thoracic esophageal cancer. Materials and methods: Patients with squamous cell carcinoma (SCC) of the thoracic esophagus newly diagnosed between February 1999 and April 2001 in our institution was recruited from our database. Definitive chemoradiotherapy consisted of two cycles of cisplatin/5FU repeated every 5 weeks, with concurrent radiation therapy of 60 Gy in 30 fractions. Up to 40 Gy radiation therapy was delivered to the cervical, periesophageal, mediastinal and perigastric lymph nodes as ENI. Results: One hundred two patients were included in this analysis, and their characteristics were as follows: median age, 65 years; male/female, 85/17; T1/T2/T3/T4, 16/11/61/14; N0/N1, 48/54; M0/M1, 84/18. The median follow-up period for the surviving patients was 41 months. Sixty patients achieved complete response (CR). After achieving CR, only one (1.0%; 95% CI, 0-5.3%) patient experienced elective nodal failure without any other site of recurrence. Conclusion: In CRT for esophageal SCC, ENI is effective for preventing regional nodal failure. Further evaluation of whether ENI leads to an improved overall survival is needed.

  2. Prediction of nodal involvement in primary rectal carcinoma without invasion to pelvic structures: accuracy of preoperative CT, MR, and DWIBS assessments relative to histopathologic findings.

    Directory of Open Access Journals (Sweden)

    Jun Zhou

    Full Text Available OBJECTIVE: To investigate the accuracy of preoperative computed tomography (CT, magnetic resonance (MR imaging and diffusion-weighted imaging with background body signal suppression (DWIBS in the prediction of nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures. METHODS AND MATERIALS: Fifty-two subjects with primary rectal cancer were preoperatively assessed by CT and MRI at 1.5 T with a phased-array coil. Preoperative lymph node staging with imaging modalities (CT, MRI, and DWIBS were compared with the final histological findings. RESULTS: The accuracy of CT, MRI, and DWIBS were 57.7%, 63.5%, and 40.4%. The accuracy of DWIBS with higher sensitivity and negative predictive value for evaluating primary rectal cancer patients was lower than that of CT and MRI. Nodal staging agreement between imaging and pathology was fairly strong for CT and MRI (Kappa value = 0.331 and 0.348, P<0.01 but was relatively weaker for DWIBS (Kappa value = 0.174, P<0.05. The accuracy was 57.7% and 59.6%, respectively, for CT and MRI when the lymph node border information was used as the criteria, and was 57.7% and 61.5%, respectively, for enhanced CT and MRI when the lymph node enhancement pattern was used as the criteria. CONCLUSION: MRI is more accurate than CT in predicting nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures. DWIBS has a great diagnostic value in differentiating small malignant from benign lymph nodes.

  3. Absence of bile acid malabsorption as a late effect of pelvic irradiation

    International Nuclear Information System (INIS)

    Schuster, J.J.; Stryker, J.A.; Demers, L.M.; Mortel, R.

    1986-01-01

    The pathophysiology of chronic radiation-induced diarrhea was evaluated in 28 patients who had undergone pelvic irradiation for gynecologic neoplasms 2 to 7 years previously. Twenty-seven patients undergoing radiotherapy with techniques that did not require abdominal or pelvic irradiation served as controls. The glycine conjugates of cholic acid (GC) were measured in serum by radioimmunoassay. Fasting and 2 hr. pp GC levels for the pelvic irradiated patients were 11.0 +/- 11.1 (mean +/- SD) and 24.8 +/- 17.3 micrograms/dl. Fasting and 2 hr. pp GC levels for controls were 12.6 +/- 7.4 and 28.0 +/- 14.7. There were no significant differences in the post-prandial increases in serum GC between pelvic irradiated patients and controls (p = .23, Type II error probability = .13). There was also no significant difference in the 2 hr. pp and fasting GC ratio (p = .39). There was significant difference between the stool frequency (p less than .01) and the prevalence of diarrhea (p less than .02) between pelvic irradiated patients and controls. The data suggest that bile acid malabsorption due to ileal dysfunction is not an inevitable late complication of pelvic irradiation and is not the major determinant in the pathophysiology of chronic radiation-induced diarrhea

  4. Clinical target volume delineation including elective nodal irradiation in preoperative and definitive radiotherapy of pancreatic cancer

    Directory of Open Access Journals (Sweden)

    Caravatta Luciana

    2012-06-01

    Full Text Available Abstract Background Radiotherapy (RT is widely used in the treatment of pancreatic cancer. Currently, recommendation has been given for the delineation of the clinical target volume (CTV in adjuvant RT. Based on recently reviewed pathologic data, the aim of this study is to propose criteria for the CTV definition and delineation including elective nodal irradiation (ENI in the preoperative and definitive treatment of pancreatic cancer. Methods The anatomical structures of interest, as well as the abdominal vasculature were identified on intravenous contrast-enhanced CT scans of two different patients with pancreatic cancer of the head and the body. To delineate the lymph node area, a margin of 10 mm was added to the arteries. Results We proposed a set of guidelines for elective treatment of high-risk nodal areas and CTV delineation. Reference CT images were provided. Conclusions The proposed guidelines could be used for preoperative or definitive RT for carcinoma of the head and body of the pancreas. Further clinical investigations are needed to validate the defined CTVs.

  5. Incidental Prophylactic Nodal Irradiation and Patterns of Nodal Relapse in Inoperable Early Stage NSCLC Patients Treated With SBRT: A Case-Matched Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lao, Louis [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Auckland City Hospital, Auckland (New Zealand); Hope, Andrew J. [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Maganti, Manjula [Department of Biostatistics, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Brade, Anthony; Bezjak, Andrea; Saibishkumar, Elantholi P.; Giuliani, Meredith; Sun, Alexander [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Cho, B. C. John, E-mail: john.cho@rmp.uhn.on.ca [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada)

    2014-09-01

    Purpose: Reported rates of non-small cell lung cancer (NSCLC) nodal failure following stereotactic body radiation therapy (SBRT) are lower than those reported in the surgical series when matched for stage. We hypothesized that this effect was due to incidental prophylactic nodal irradiation. Methods and Materials: A prospectively collected group of medically inoperable early stage NSCLC patients from 2004 to 2010 was used to identify cases with nodal relapses. Controls were matched to cases, 2:1, controlling for tumor volume (ie, same or greater) and tumor location (ie, same lobe). Reference (normalized to equivalent dose for 2-Gy fractions [EQD2]) point doses at the ipsilateral hilum and carina, demographic data, and clinical outcomes were extracted from the medical records. Univariate conditional logistical regression analyses were performed with variables of interest. Results: Cases and controls were well matched except for size. The controls, as expected, had larger gross tumor volumes (P=.02). The mean ipsilateral hilar doses were 9.6 Gy and 22.4 Gy for cases and controls, respectively (P=.014). The mean carinal doses were 7.0 Gy and 9.2 Gy, respectively (P=.13). Mediastinal nodal relapses, with and without ipsilateral hilar relapse, were associated with mean ipsilateral hilar doses of 3.6 Gy and 19.8 Gy, respectively (P=.01). The conditional density plot appears to demonstrate an inverse dose-effect relationship between ipsilateral hilar normalized total dose and risk of ipsilateral hilar relapse. Conclusions: Incidental hilar dose greater than 20 Gy is significantly associated with fewer ipsilateral hilar relapses in inoperable early stage NSCLC patients treated with SBRT.

  6. Incidental Prophylactic Nodal Irradiation and Patterns of Nodal Relapse in Inoperable Early Stage NSCLC Patients Treated With SBRT: A Case-Matched Analysis

    International Nuclear Information System (INIS)

    Lao, Louis; Hope, Andrew J.; Maganti, Manjula; Brade, Anthony; Bezjak, Andrea; Saibishkumar, Elantholi P.; Giuliani, Meredith; Sun, Alexander; Cho, B. C. John

    2014-01-01

    Purpose: Reported rates of non-small cell lung cancer (NSCLC) nodal failure following stereotactic body radiation therapy (SBRT) are lower than those reported in the surgical series when matched for stage. We hypothesized that this effect was due to incidental prophylactic nodal irradiation. Methods and Materials: A prospectively collected group of medically inoperable early stage NSCLC patients from 2004 to 2010 was used to identify cases with nodal relapses. Controls were matched to cases, 2:1, controlling for tumor volume (ie, same or greater) and tumor location (ie, same lobe). Reference (normalized to equivalent dose for 2-Gy fractions [EQD2]) point doses at the ipsilateral hilum and carina, demographic data, and clinical outcomes were extracted from the medical records. Univariate conditional logistical regression analyses were performed with variables of interest. Results: Cases and controls were well matched except for size. The controls, as expected, had larger gross tumor volumes (P=.02). The mean ipsilateral hilar doses were 9.6 Gy and 22.4 Gy for cases and controls, respectively (P=.014). The mean carinal doses were 7.0 Gy and 9.2 Gy, respectively (P=.13). Mediastinal nodal relapses, with and without ipsilateral hilar relapse, were associated with mean ipsilateral hilar doses of 3.6 Gy and 19.8 Gy, respectively (P=.01). The conditional density plot appears to demonstrate an inverse dose-effect relationship between ipsilateral hilar normalized total dose and risk of ipsilateral hilar relapse. Conclusions: Incidental hilar dose greater than 20 Gy is significantly associated with fewer ipsilateral hilar relapses in inoperable early stage NSCLC patients treated with SBRT

  7. Effect of pelvic irradiation on the absorption of bile acids

    International Nuclear Information System (INIS)

    Stryker, J.A.; Demers, L.M.

    1979-01-01

    The pathophysiology of radiation-induced diarrhea was evaluated in 17 patients undergoing pelvic irradiation for gynecological malignancies. The glycine conjugates of cholic acid (GC) and chenodeoxycholic acid (GCDC) were measured in serum by radioimmunoassay. Fasting and 2 hour post prandial (pp) determinations were performed prior to and in the fifth week of radiotherapy. The pre-treatment fasting and 2 hour pp GC levels were 0.20 +- 0.29 (mean +- SD) and 0.48 +- 0.47 μM. In the fifth week the fasting and 2 hour pp GC levels were 0.16 +- 0.23 and 0.25 +- 0.27 μM. The first week fasting and 2 hour pp GCDC levels were 0.32 +- 0.47 and 0.80 +- 0.83 μM: in the fifth week they were 0.10 +- 0.06 and 0.33 +- 0.27 μM. The differences between the first and the fifth week post prandial increases in serum GC and GCDC levels were significant (P<0.02). The reduced post prandial increases in serum GC and GCDC in the fifth week of radiotherapy occurred at a time when the patients' daily stool frequencies were significantly increased (P<0.01). The data suggest that a cholerrheic enteropathy is the major determinant in the pathophysiology of radiation-induced diarrhea

  8. Ovarian carcinoma: improved survival following abdominopelvic irradiation in patients with a completed pelvic operation

    International Nuclear Information System (INIS)

    Dembo, A.J.; Bush, R.S.; Beale, F.A.; Bean, H.A.; Pringle, J.F.; Sturgeon, J.; Reid, J.G.

    1979-01-01

    A prospective, stratified, randomized study of 190 postoperative ovarian carcinoma patients with Stages IB, II, and III (asymptomatic) presentations is reported. The median time of follow-up was 52 months. Patients in whom bilateral salpingo-oophorectomy and hysterectomy (BSOH) could not be completed because of extensive pelvic tumor had a poor prognosis which did not differ for any of the therapies tested. When BSOH was completed, pelvic plus abdominopelvic irradiation (P + AB) with no diaphragmatic shielding significantly improved patient survival rate and long-term control of occult upper abdominal disease in approximately 25% more patients than pelvic irradiation alone or followed by adjuvant daily chlorambucil therapy. The effectiveness of P + AB in BSOH-completed patients was independent of stage or tumor grade and was most clearly appreciated in patients with all gross tumor removed. Chlorambucil added to pelvic irradiation delayed the time to treatment failure without reducing the number of treatment failures

  9. Local field radiotherapy without elective nodal irradiation for postoperative loco-regional recurrence of esophageal cancer.

    Science.gov (United States)

    Kimoto, Takuya; Yamazaki, Hideya; Suzuki, Gen; Aibe, Norihiro; Masui, Koji; Tatekawa, Kotoha; Sasaki, Naomi; Fujiwara, Hitoshi; Shiozaki, Atsushi; Konishi, Hirotaka; Nakamura, Satoaki; Yamada, Kei

    2017-09-01

    Radiotherapy is an effective treatment for the postoperative loco-regional recurrence of esophageal cancer; however, the optimal treatment field remains controversial. This study aims to evaluate the outcome of local field radiotherapy without elective nodal irradiation for postoperative loco-regional recurrence of esophageal cancer. We retrospectively investigated 35 patients treated for a postoperative loco-regional recurrence of esophageal cancer with local field radiotherapy between December 2008 and March 2016. The median irradiation dose was 60 Gy (range: 50-67.5 Gy). Thirty-one (88.6%) patients received concurrent chemotherapy. The median follow-up period was 18 months (range: 5-94 months). The 2-year overall survival was 55.7%, with a median survival time of 29.9 months. In the univariate analysis, the maximal diameter ≤20 mm (P = 0.0383), solitary lesion (P = 0.0352), and the complete remission after treatment (P = 0.00411) had a significantly better prognosis. A total of 27 of 35 patients (77.1%) had progressive disease (loco-regional failure [n = 9], distant metastasis [n = 7], and both loco-regional failure and distant metastasis [n = 11]). No patients had Grade 3 or greater mucositis. Local field radiotherapy is a considerable treatment option for postoperative loco-regional recurrence of esophageal cancer. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  10. Indiana pouch continent urinary reservoir in patients with previous pelvic irradiation

    International Nuclear Information System (INIS)

    Mannel, R.S.; Braly, P.S.; Buller, R.E.

    1990-01-01

    Little information exists on the use of continent urinary reservoirs in patients with previous pelvic irradiation. We report the use of the Indiana pouch urinary reservoir in ten women with a history of pelvic irradiation for cervical cancer, of whom eight underwent a total pelvic exenteration for recurrent pelvic tumor and two had diversion for radiation-induced vesicovaginal fistula. All ten women achieved daytime continence, with a median time between catheterizations of 4.5 hours and a median pouch capacity of 500 mL. There was no evidence of leakage from the reservoir or significant ureteral reflux or obstruction on postoperative radiographic evaluation. No patient has required reoperation or had significant postoperative complications with the technique described

  11. Ovarian function following pelvic irradiation in prepubertal and pubertal girls and young adult women

    International Nuclear Information System (INIS)

    Schuck, A.; Hamelmann, V.; Braemswig, J.H.

    2005-01-01

    Purpose: To analyze the effect of pelvic radiotherapy on ovarian function in prepubertal and pubertal girls and young adult women. Patients and methods: In a retrospective monoinstitutional analysis, patients 15 Gy to the ovaries developed hormone failure. In one case of a patient receiving an ovarian dose of 15 Gy, hormone failure was not found. In case of pelvic irradiation excluding at least one ovary, approximately half of the patients developed ovarian dysfunction, probably also due to the effects of polychemotherapy. (orig.)

  12. Patterns of practice of regional nodal irradiation in breast cancer: results of the European Organization for Research and Treatment of Cancer (EORTC) NOdal Radiotherapy (NORA) survey.

    Science.gov (United States)

    Belkacemi, Y; Kaidar-Person, O; Poortmans, P; Ozsahin, M; Valli, M-C; Russell, N; Kunkler, I; Hermans, J; Kuten, A; van Tienhoven, G; Westenberg, H

    2015-03-01

    Predicting outcome of breast cancer (BC) patients based on sentinel lymph node (SLN) status without axillary lymph node dissection (ALND) is an area of uncertainty. It influences the decision-making for regional nodal irradiation (RNI). The aim of the NORA (NOdal RAdiotherapy) survey was to examine the patterns of RNI. A web-questionnaire, including several clinical scenarios, was distributed to 88 EORTC-affiliated centers. Responses were received between July 2013 and January 2014. A total of 84 responses were analyzed. While three-dimensional (3D) radiotherapy (RT) planning is carried out in 81 (96%) centers, nodal areas are delineated in only 51 (61%) centers. Only 14 (17%) centers routinely link internal mammary chain (IMC) and supraclavicular node (SCN) RT indications. In patients undergoing total mastectomy (TM) with ALND, SCN-RT is recommend by 5 (6%), 53 (63%) and 51 (61%) centers for patients with pN0(i+), pN(mi) and pN1, respectively. Extra-capsular extension (ECE) is the main factor influencing decision-making RNI after breast conserving surgery (BCS) and TM. After primary systemic therapy (PST), 49 (58%) centers take into account nodal fibrotic changes in ypN0 patients for RNI indications. In ypN0 patients with inner/central tumors, 23 (27%) centers indicate SCN-RT and IMC-RT. In ypN1 patients, SCN-RT is delivered by less than half of the centers in patients with ypN(i+) and ypN(mi). Twenty-one (25%) of the centers recommend ALN-RT in patients with ypN(mi) or 1-2N+ after ALND. Seventy-five (90%) centers state that age is not considered a limiting factor for RNI. The NORA survey is unique in evaluating the impact of SLNB/ALND status on adjuvant RNI decision-making and volumes after BCS/TM with or without PST. ALN-RT is often indicated in pN1 patients, particularly in the case of ECE. Besides the ongoing NSABP-B51/RTOG and ALLIANCE trials, NORA could help to design future specific RNI trials in the SLNB era without ALND in patients receiving or not PST.

  13. Endometrial cancers occurring 10 or more years after pelvic irradiation for carcinoma

    International Nuclear Information System (INIS)

    Rodriguez, J.; Hart, W.R.

    1982-01-01

    Fifteen patients who developed cancer of the endometrium 10 or more years after pelvic irradiation for carcinoma were selected for study from a group of 64 cases of postirradiation malignant pelvic tumors diagnosed during a 48-year span. The average interval between radiotherapy and diagnosis of the subsequent endometrial cancer was 17.2 years. Irradiation initially had been done for squamous cell carcinoma of the cervix in 13 cases (87%) and for ovarian tumors in two instances. Almost all patients had received megavoltage external radiation combined with radium implants. Two-thirds of the tumors were adenocarcinomas and one-third were carcinosarcomas (either homologous or heterologous). Although the risk of second primary malignant tumors following therapeutic irradiation for pelvic tumors probably is very low, the emergence of new genital tract cancers in long-term survivors must be anticipated, regardless of whether the postirradiation cancers are spontaneous or radiation-induced

  14. Proton beam radiotherapy as part of comprehensive regional nodal irradiation for locally advanced breast cancer.

    Science.gov (United States)

    Verma, Vivek; Iftekaruddin, Zaid; Badar, Nida; Hartsell, William; Han-Chih Chang, John; Gondi, Vinai; Pankuch, Mark; Gao, Ming; Schmidt, Stacey; Kaplan, Darren; McGee, Lisa

    2017-05-01

    This study evaluates acute toxicity outcomes in breast cancer patients treated with adjuvant proton beam therapy (PBT). From 2011 to 2016, 91 patients (93 cancers) were treated with adjuvant PBT targeting the intact breast/chest wall and comprehensive regional nodes including the axilla, supraclavicular fossa, and internal mammary lymph nodes. Toxicity was recorded weekly during treatment, one month following treatment, and then every 6months according to the Common Terminology Criteria for Adverse Events (CTCAE) v4.0. Charts were retrospectively reviewed to verify toxicities, patient parameters, disease and treatment characteristics, and disease-related outcomes. Median follow-up was 15.5months. Median PBT dose was 50.4 Gray relative biological effectiveness (GyRBE), with subsequent boost as clinically indicated (N=61, median 10 GyRBE). Chemotherapy, when administered, was given adjuvantly (N=42) or neoadjuvantly (N=46). Grades 1, 2, and 3 dermatitis occurred in 23%, 72%, and 5%, respectively. Eight percent required treatment breaks owing to dermatitis. Median time to resolution of dermatitis was 32days. Grades 1, 2, and 3 esophagitis developed in 31%, 33%, and 0%, respectively. PBT displays acceptable toxicity in the setting of comprehensive regional nodal irradiation. Copyright © 2017. Published by Elsevier B.V.

  15. Designing Targets for Elective Nodal Irradiation in Lung Cancer Radiotherapy: A Planning Study

    International Nuclear Information System (INIS)

    Kepka, Lucyna; Tatro, Daniel; Moran, Jean M.; Quint, Leslie E.; Hayman, James A.; Ten Haken, Randall K.; Kong Fengming

    2009-01-01

    Purpose: To assess doses received by mediastinal and hilar lymph node stations (LNS) delineated according to published recommendations when 'standard' two-dimensional (2D) elective fields are applied and to assess doses to critical structures when fields are designed using 2D and three-dimensional (3D) treatment planning for elective irradiation. Methods and Materials: LNS were delineated on axial CT scans according to existing recommendations. For each case and tumor location, 2D anteroposterior-posteroanterior (AP-PA) elective fields were applied using the AP-PA CT topograms. From the 2D portal fields, 3D dose distributions were then calculated to particular LNS. Next, 3D plans were prepared for elective nodal irradiation for tumors of different lobes. Doses for critical structures were compared for 2D and 3D plans. Results: LNS 1/2R, 1/2L, 3A, 3P, 5, 6, and 8 were not adequately covered in a substantial part of plans by standard 2D portals when guidelines for delineation were strictly followed. The magnitude of the lack of coverage increased with margin application. There was a trend for a higher yet probably still safe dose delivered to lung for 3D plans compared with 2D plans with a prescription dose of 45 Gy. Conclusions: 2D fields did not entirely cover LNS delineated according to the recommendations for 3D techniques. A strict adherence to these guidelines may lead to larger portals than traditionally constructed using 2D methods. Some modifications for clinical implementation are discussed.

  16. Hypofractionated regional nodal irradiation for breast cancer: Examining the data and potential for future studies

    International Nuclear Information System (INIS)

    Badiyan, Shahed N.; Shah, Chirag; Arthur, Douglas; Khan, Atif J.; Freedman, Gary; Poppe, Matthew M.; Vicini, Frank A.

    2014-01-01

    Limited data are available examining the role of hypofractionated radiation schedules in the management of women requiring regional nodal irradiation (RNI). The purpose of this review is to examine the available literature for the efficacy (where available) and toxicity of hypofractionated radiation schedules in breast cancer with RNI limited to the axilla and supraclavicular regions. Multiple randomized and prospective studies have documented the safety and efficacy of hypofractionated schedules delivering whole breast irradiation (WBI) alone. Subsets from these randomized trials and smaller prospective/single-institution studies have documented the feasibility of hypofractionated RNI but the limited numbers prevent definitive conclusions and limited efficacy data are available. With regard to possible toxicity affecting organs at risk with RNI, key structures include the breast, skin, heart, lungs, axilla (lymphedema), and brachial plexus. Based on data from several randomized trials, hypofractionated radiation is not associated with significant changes in breast toxicity/cosmesis or cardiac toxicity; the addition of hypofractionated RNI would not be expected to change the rates of breast or cardiac toxicity. While RNI has been shown to increase rates of pulmonary toxicity, hypofractionated RNI has not been associated with more frequent pulmonary complications than standard RNI. Moving forward, future studies will have to evaluate for increased lung toxicity. With regard to lymphedema, data from randomized hypofractionated WBI trials failed to demonstrate an increase in lymphedema and smaller studies utilizing hypofractionated RNI have failed to as well. Data from head and neck cancer as well as hypofractionated breast radiation with RNI have failed to demonstrate an increase in brachial plexopathy with the exception of older trials that used much larger dose per fraction (>4 Gy/fraction) schedules. At this time, published data support the feasibility of

  17. Long-term outcome of concurrent chemoradiotherapy with elective nodal irradiation for inoperable esophageal cancer.

    Science.gov (United States)

    Jing, Zhao; Chen, Tian; Zhang, Xuebang; Wu, Shixiu

    2017-09-01

    Elective nodal irradiation (ENI) might improve overall survival in patients with inoperable esophageal cancer. We conducted a retrospective analysis to assess the long-term survival and toxicity of esophageal cancer patients treated with ENI versus conventional-field irradiation (CFI). All data in the present study were based on our institutional experience from 2000 to 2005 of patients with inoperable esophageal cancer treated with ENI or CFI plus two concurrent cycles of paclitaxel/cisplatin. Based on the inclusion and exclusion criteria, 89 patients were included in the analysis. Of these patients, 51 were treated with ENI, whereas 38 were treated with CFI. For the per-protocol population, the patients in the ENI group significantly improved in terms of their 10-year disease-specific overall survival (43.1% vs 10.5%, P = 0.019), 10-year disease-free survival (36.7% vs 10.2%, P = 0.040) and 10-year local recurrence-free survival (47.2% vs 17.2%, P = 0.018) compared with the CFI group. Aside from radiation esophagitis, the incidence of grade 3 or greater acute toxicities did not differ between the two groups. Multivariate analysis showed that radiation field, tumor length and clinical stage were independent prognostic factors associated with OS. Concurrent chemoradiotherapy with ENI improves both disease-specific overall survival and loco-regional control in patients with inoperable esophageal cancer receiving per-protocol treatment. The regimen has a manageable tolerability profile. © 2017 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  18. Omitting elective nodal irradiation during thoracic irradiation in limited-stage small cell lung cancer--evidence from a phase II trial.

    Science.gov (United States)

    Colaco, Rovel; Sheikh, Hamid; Lorigan, Paul; Blackhall, Fiona; Hulse, Paul; Califano, Raffaele; Ashcroft, Linda; Taylor, Paul; Thatcher, Nicholas; Faivre-Finn, Corinne

    2012-04-01

    Omitting elective nodal irradiation (ENI) in limited-stage disease small cell lung cancer (LD-SCLC) is expected to result in smaller radiation fields. We report on data from a randomised phase II trial that omitted ENI in patients receiving concurrent chemo-radiotherapy for LD-SCLC. 38 patients with LD-SCLC were randomised to receive once-daily (66 Gy in 33 fractions) or twice-daily (45 Gy in 30 fractions) radiotherapy (RT). 3D-conformal RT was given concurrently with cisplatin and etoposide starting with the second cycle of a total of four cycles. The gross tumour volume was defined as primary tumour with involved lymph nodes (nodes ≥1 cm in short axis) identifiable with CT imaging. ENI was not used. Six recurrence patterns were identified: recurrence within planning target volume (PTV) only, recurrence within PTV+regional nodal recurrence and/or distant recurrence, isolated nodal recurrence outside PTV, nodal recurrence outside PTV+distant recurrence, distant metastases only and no recurrence. At median follow-up 16.9 months, 31/38 patients were evaluable and 14/31 patients had relapsed. There were no isolated nodal recurrences. Eight patients relapsed with intra-thoracic disease: 2 within PTV only, 4 within PTV and distantly and 2 with nodal recurrence outside PTV plus distant metastases. Rates of grade 3+ acute oesophagitis and pneumonitis in the 31 evaluable patients were 23 and 3% respectively. In our study of LD-SCLC, omitting ENI based on CT imaging was not associated with a high risk of isolated nodal recurrence, although further prospective studies are needed to confirm this. Routine ENI omission will be further evaluated prospectively in the ongoing phase III CONVERT trial (NCT00433563). Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Complications from high-dose para-aortic and pelvic irradiation for malignant genitourinary tumors

    International Nuclear Information System (INIS)

    Komaki, R.; Barber-Derus, S.; Glisch, C.; Lawton, C.A.; Cox, J.D.; Wilson, J.F.

    1986-01-01

    Between 1967 and 1982, 59 patients (33 with gynecologic malignancies and 26 with malignant tumors of the genitourinary system) received irradiation of 40 Gy or more for metastases to the para-aortic lymph nodes, in addition to pelvic irradiation. Disease in the para-aortic lymph nodes was controlled in 50 patients; the treatment failed in nine. Moderately acute side effects were seen in 25 patients, but none was severe. Late effects of irradiation were moderate in five patients and severe in three. Thirty patients are alive at 5 years. The benefits of local control and prolonged disease-free survival appear to outweigh considerably the risk of late effects from pelvic and para-aortic irradiation for advanced malignant tumors of the genitourinary system

  20. Stricture of the sigmoid colon after pelvic irradiation. Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Yutaka; Nakamura, Katsuya; Tasaki, Akira; Tsutsumi, Nobuo; Terasaka, Reiji [Shin Kokura Hospital, Kitakyushu, Fukuoka (Japan); Taguchi, Kenichi [Kyushu Univ., Fukuoka (Japan). Graduate School of Medical Sciences

    2002-07-01

    Disorders of the large and small intestines after pelvic irradiation are classified into early and late complications. Common late complications are stricture and perforation. Some cases with such complications are indicated for surgical therapy. Moreover, it is suggested that radiation induced cancer can occur in patients surviving more than 5 years after radiotherapy. Patient 1, a 78-year-old woman, had been treated by surgery and pelvic irradiation for uterine cancer 20 years earlier. She had been suffered from constipation for a long time after the treatment. This time, examinations revealed a whole- circumference stricture and cancer of the sigmoid colon. Sigmoidectomy was performed. Pathological diagnosis was carcinoma in radiation colitis. Patient 2, a 73-year-old woman, had been treated by surgery and pelvic irradiation for uterine cancer 15 years earlier. This time, she admitted to the hospital because of intestinal bleeding. Angiography showed hemorrhage in the ileum. Arterial injection of vasopressin succeeded in hemostasis. However, the procedure caused marked stricture of the sigmoid colon unexpectedly. A sigmoidectomy and a partial resection of the ileum were performed. Pathological diagnosis was radiation colitis and ileitis without malignant findings. Patients with long interval after pelvic irradiation must be carefully followed from the standpoint of late complications and cancer. (author)

  1. Locally advanced prostatic cancer: experience with combined pelvic external beam irradiation and interstitial thermobrachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hancock, Steven L; Kapp, Daniel S; Goffinet, Don R; Prionas, Stavros; Cox, Richard S; Bagshaw, Malcolm A

    1995-07-01

    Purpose: Recurrence of prostatic carcinoma within the prostate gland remains a significant problem for patients who present with locally advanced disease. In an attempt to improve the local control of such tumors, an iridium-192 transperineal, template-guided prostatic implant was combined wit radiofrequency-induced hyperthermia after external beam irradiation of the pelvic lymph nodes and prostate gland. This study evaluates the influence of pre-treatment patient characteristics and treatment parameters upon outcome. Materials and Methods: Between July 1987 and April 1992 33 patients with adenocarcinoma of the prostate were selected for treatment: 28 of these patients had extensive local disease on clinical examination (AJCC-4 stages T2b or c: 9 patients; T3: 19 patients); two patients with T2a tumors had Gleason grade 5 + 4 disease or disproportionately high prostate specific antigen (PSA) values and a mass encroaching upon the bladder on computerized tomographic scan. Three patients with more clinically limited T2a or T2b involvement elected implantation in lieu of an external beam irradiation boost. The mean pre-treatment serum PSA value was 25.6 ng/ml (Hybritech scale), with values of above 19 ng/ml for 17 of the patients. Treatment consisted of 50 Gy of external beam irradiation to the prostate and pelvic lymph nodes followed by a transperineal needle implant of the prostate gland. Thirty-two patients had no evidence of pelvic nodal involvement during exploration at laparotomy performed after external irradiation, and 25 of these had lymph node samplings that were histologically negative for metastasis. Perineal template oriented needles were placed by inspection and palpation at laparotomy; 2 were performed closed under ultrasound guidance. Needles were afterloaded with {sup 192}Ir to provide a dose of 30 Gy to the periphery of the prostate gland. Interstitial radiofrequency-induced hyperthermia treatments were given in conjunction with the implant, one just

  2. Prospective study of irradiation and magnification on a pelvic imaging: EOS system versus conventional radiography

    International Nuclear Information System (INIS)

    Demoulin, Loic

    2015-01-01

    The pelvic x-ray is essential for the orthopedic practise. Recently, EOS system has been developed with technology to limit irradiation and theoretically not create magnification. The objective of this study was to evaluate the EOS system realizing a pelvic x-ray. All patients who underwent hip replacement between September 2014 and April 2015 have benefited pelvis radiograph with the 2 techniques, after surgery. The size of the head was measured with both techniques and compared to the established size. Irradiation of each technique was listed. A correlation study was carried out with the body mass index (BMI) of the patient. Irradiation was significantly greater with conventional radiography than with the EOS system: PDS of conventional radiography = 15.0 (10.5; 25.2) against the EOS system PDS = 8.2 (7.1; 9.7), p ≤0.0001. It was found a significant correlation between BMI and irradiation, particularly with conventional radiography. About expansion, the EOS system not create any except in 4 cases, unlike the conventional radiograph. The EOS system significantly decreases irradiation in all patients, compared to the conventional radiography, and it do not create magnification when realizing a pelvic x-ray, even in overweight patients [fr

  3. Pelvic re-irradiation using stereotactic ablative radiotherapy (SABR): A systematic review.

    Science.gov (United States)

    Murray, Louise Janet; Lilley, John; Hawkins, Maria A; Henry, Ann M; Dickinson, Peter; Sebag-Montefiore, David

    2017-11-01

    To perform a systematic review regarding the use of stereotactic ablative radiotherapy (SABR) for the re-irradiation of recurrent malignant disease within the pelvis, to guide the clinical implementation of this technique. A systematic search strategy was adopted using the MEDLINE, EMBASE and Cochrane Library databases. 195 articles were identified, of which 17 were appropriate for inclusion. Studies were small and data largely retrospective. In total, 205 patients are reported to have received pelvic SABR re-irradiation. Dose and fractionation schedules and re-irradiated volumes are highly variable. Little information is provided regarding organ at risk constraints adopted in the re-irradiation setting. Treatment appears well-tolerated overall, with nine grade 3 and six grade 4 toxicities amongst thirteen re-irradiated patients. Local control at one year ranged from 51% to 100%. Symptomatic improvements were also noted. For previously irradiated patients with recurrent pelvic disease, SABR re-irradiation could be a feasible intervention for those who otherwise have limited options. Evidence to support this technique is limited but shows initial promise. Based on the available literature, suggestions for a more formal SABR re-irradiation pathway are proposed. Prospective studies and a multidisciplinary approach are required to optimise future treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Clinical outcome of extended-field irradiation vs. pelvic irradiation using intensity-modulated radiotherapy for cervical cancer.

    Science.gov (United States)

    Ouyang, Yi; Wang, Yanhong; Chen, Kai; Cao, Xinping; Zeng, Yiming

    2017-12-01

    The aim of the present study was to evaluate the distinctions in survival and toxicity between patients with cervical cancer with common iliac node or para-aortic node involvement, who were treated with extended-field intensity-modulated radiotherapy (EF-IMRT) and patients with or without lower involved pelvic nodes, who were treated with pelvic IMRT. A total of 55 patients treated with EF-IMRT and 52 patients treated with pelvic IMRT at the Sun Yat-Sen University Cancer Center (Guangzhou, China) were retrospectively analyzed. Patients treated with EF-IMRT had the highest level of lymph node involvement to the para-aortic or common iliac nodes, while patients treated with pelvic IMRT had no para-aortic or common iliac nodes involved (Pirradiation was a protective prognostic factor for OS and DFS. A total of 16 patients in the EF-IMRT group and 13 patients in the pelvic IMRT group experienced treatment failure (P=0.67), with the patterns of failure being the same for the two groups (P=0.88). The cumulative incidence of grade 3 and 4 acute toxicities in the EF-IMRT group was 34.5%, in comparison with 19.2% in the pelvic group (P=0.048). The results of the present study suggest that patients with cervical cancer with grossly involved common iliac or para-aortic nodes should be electively subjected to EF irradiation to improve the survival and alter patterns of recurrence. Notably, EF irradiation delivered via IMRT exhibits an increased toxicity incidence, however, this remains within an acceptable range.

  5. Selective Nodal Irradiation on Basis of 18FDG-PET Scans in Limited-Disease Small-Cell Lung Cancer: A Prospective Study

    International Nuclear Information System (INIS)

    Loon, Judith van; De Ruysscher, Dirk; Wanders, Rinus; Boersma, Liesbeth; Simons, Jean; Oellers, Michel; Dingemans, Anne-Marie C.; Hochstenbag, Monique; Bootsma, Gerben; Geraedts, Wiel; Pitz, Cordula; Teule, Jaap; Rhami, Ali; Thimister, Willy; Snoep, Gabriel; Dehing-Oberije, Cary; Lambin, Philippe

    2010-01-01

    Purpose: To evaluate the results of selective nodal irradiation on basis of 18 F-deoxyglucose positron emission tomography (PET) scans in patients with limited-disease small-cell lung cancer (LD-SCLC) on isolated nodal failure. Methods and Materials: A prospective study was performed of 60 patients with LD-SCLC. Radiotherapy was given to a dose of 45 Gy in twice-daily fractions of 1.5 Gy, concurrent with carboplatin and etoposide chemotherapy. Only the primary tumor and the mediastinal lymph nodes involved on the pretreatment PET scan were irradiated. A chest computed tomography (CT) scan was performed 3 months after radiotherapy completion and every 6 months thereafter. Results: A difference was seen in the involved nodal stations between the pretreatment 18 F-deoxyglucose PET scans and computed tomography scans in 30% of patients (95% confidence interval, 20-43%). Of the 60 patients, 39 (65%; 95% confidence interval [CI], 52-76%) developed a recurrence; 2 patients (3%, 95% CI, 1-11%) experienced isolated regional failure. The median actuarial overall survival was 19 months (95% CI, 17-21). The median actuarial progression-free survival was 14 months (95% CI, 12-16). 12% (95% CI, 6-22%) of patients experienced acute Grade 3 (Common Terminology Criteria for Adverse Events, version 3.0) esophagitis. Conclusion: PET-based selective nodal irradiation for LD-SCLC resulted in a low rate of isolated nodal failures (3%), with a low percentage of acute esophagitis. These findings are in contrast to those from our prospective study of CT-based selective nodal irradiation, which resulted in an unexpectedly high percentage of isolated nodal failures (11%). Because of the low rate of isolated nodal failures and toxicity, we believe that our data support the use of PET-based SNI for LD-SCLC.

  6. Analysis of influence factors on the volume of pelvic bowel irradiated for rectal cancer

    International Nuclear Information System (INIS)

    He Yuxiang; Cai Yong; Zhu Xianggao; Han Shukui; Xu Bo

    2007-01-01

    Objective: To evaluate influence of prone/ supine position, gender, operation, bladder distension on bowel irradiated for patients with rectal cancer during pelvic radiotherapy. Methods: 36 patients with rectal cancer were investigated. Treatment plans were created with three dimensional treatment planning system. The dose and volume of bowel irradiated were analyzed according to dose-volume histograms (DVH) for every patient. The prescribed dose was 50 Gy. Results: The extent of bladder distension significantly influenced the mean doses and the V 45 high dose volumes of bowel irradiated. The treatment position and gender significantly influenced the V 15 low dose volume of bowel irradiated, the operation significantly influenced the mean doses of bowel. Either prone and supine position, or preoperative and postoperative, the doses of bowel irradiated for good bladder distension were lower and the volumes were smaller than that for bad bladder distension. The V 45 high dose volume of bowel irradiated for bad and good bladder distension at prone position were 15.3% and 7.4% (P=0.023), respectively, and at postoperative 14.1% and 7.2% (P=0.014), respectively. Conclusions: The doses and volumes of pelvic bowel irradiated were significantly influenced by the extent of bladder distension, and partly influenced by the prone/supine position, gender and operation. (authors)

  7. Carcinoma of vagina 10 or more years following pelvic irradiation therapy

    International Nuclear Information System (INIS)

    Pride, G.L.; Buchler, D.A.

    1977-01-01

    Gynecologic cancer records of 4,238 patients treated between 1956 and 1974 were reviewed. Sixteen patients developed neoplasia in the cervix or vagina 10 or more years following pelvic irradiation. Three patients had squamous carcinoma in situ; the other 13 patients had invasive squamous cancer involving the upper vagina. Only 1.26 percent of invasive carcinoma of the cervix treated by radiation therapy from 1956 to 1966 presented with a late or recurrent or new primary tumor involving the vagina or cervix 10 or more years after primary treatment. The authors conclude that the risk of developing radiation-induced carcinoma in the upper vagina or cervix following pelvic irradiation is low. Follow-up Pap smears are indicated for all patients treated for cervical or vaginal malignancies by radiation therapy in order to detect vaginal neoplasia as well as recurrent carcinoma of the cervix

  8. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    International Nuclear Information System (INIS)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-01-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  9. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, David, E-mail: d-pasquier@o-lambret.fr [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Centre Galilee, Clinique de la Louviere, Lille (France); Cavillon, Fabrice [Universite Lille Nord de France, Lille (France); Faculte Libre de Medecine, Lille (France); Lacornerie, Thomas [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Touzeau, Claire [Centre Galilee, Clinique de la Louviere, Lille (France); Tresch, Emmanuelle [Unite de Methodologie et Biostatistique, Centre O. Lambret, Lille (France); Lartigau, Eric [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France)

    2013-02-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  10. A dosimetric comparison of tomotherapy and volumetric modulated arc therapy in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy.

    Science.gov (United States)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-02-01

    To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Retrospective analysis of outcome differences in preoperative concurrent chemoradiation with or without elective nodal irradiation for esophageal squamous cell carcinoma.

    Science.gov (United States)

    Hsu, Feng-Ming; Lee, Jang-Ming; Huang, Pei-Ming; Lin, Chia-Chi; Hsu, Chih-Hung; Tsai, Yu-Chieh; Lee, Yung-Chie; Chia-Hsien Cheng, Jason

    2011-11-15

    To evaluate the efficacy and patterns of failure of elective nodal irradiation (ENI) in patients with esophageal squamous cell carcinoma (SCC) undergoing preoperative concurrent chemoradiation (CCRT) followed by radical surgery. We retrospectively studied 118 patients with AJCC Stage II to III esophageal SCC undergoing preoperative CCRT (median, 36 Gy), followed by radical esophagectomy. Of them, 73 patients (62%) had ENI and 45 patients (38%) had no ENI. Patients with ENI received radiotherapy to either supraclavicular (n = 54) or celiac (n = 19) lymphatics. Fifty-six patients (57%) received chemotherapy with paclitaxel plus cisplatin. The 3-year progression-free survival, overall survival, and patterns of failure were analyzed. Distant nodal recurrence was classified into M1a and M1b regions. A separate analysis using matched cases was conducted. The median follow-up was 38 months. There were no differences in pathological complete response rate (p = 0.12), perioperative mortality rate (p = 0.48), or delayed Grade 3 or greater cardiopulmonary toxicities (p = 0.44), between the groups. More patients in the non-ENI group had M1a failure than in the ENI group, with 3-year rates of 11% and 3%, respectively (p = 0.05). However, the 3-year isolated distant nodal (M1a + M1b) failure rates were not different (ENI, 10%; non-ENI, 14%; p = 0.29). In multivariate analysis, pathological nodal status was the only independent prognostic factor associated with overall survival (hazard ratio = 1.78, p = 0.045). The 3-year overall survival and progression-free survival were 45% and 45%, respectively, in the ENI group, and 52% and 43%, respectively, in the non-ENI group (p = 0.31 and 0.89, respectively). Matched cases analysis did not show a statistical difference in outcomes between the groups. ENI reduced the M1a failure rate but was not associated with improved outcomes in patients undergoing preoperative CCRT for esophageal SCC. Pathological nodal metastasis predicted poor

  12. Retrospective Analysis of Outcome Differences in Preoperative Concurrent Chemoradiation With or Without Elective Nodal Irradiation for Esophageal Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Feng-Ming [Department of Oncology, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan (China); Cancer Research Center, National Taiwan University College of Medicine, Taipei, Taiwan (China); Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan (China); Lee, Jang-Ming; Huang, Pei-Ming [Department of Surgery, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan (China); Lin, Chia-Chi; Hsu, Chih-Hung; Tsai, Yu-Chieh [Department of Oncology, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan (China); Cancer Research Center, National Taiwan University College of Medicine, Taipei, Taiwan (China); Lee, Yung-Chie [Department of Surgery, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan (China); Chia-Hsien Cheng, Jason, E-mail: jasoncheng@ntu.edu.tw [Department of Oncology, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan (China); Cancer Research Center, National Taiwan University College of Medicine, Taipei, Taiwan (China); Graduate Institute of Oncology, National Taiwan University College of Medicine, Taipei, Taiwan (China); Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan (China)

    2011-11-15

    Purpose: To evaluate the efficacy and patterns of failure of elective nodal irradiation (ENI) in patients with esophageal squamous cell carcinoma (SCC) undergoing preoperative concurrent chemoradiation (CCRT) followed by radical surgery. Methods and Materials: We retrospectively studied 118 patients with AJCC Stage II to III esophageal SCC undergoing preoperative CCRT (median, 36 Gy), followed by radical esophagectomy. Of them, 73 patients (62%) had ENI and 45 patients (38%) had no ENI. Patients with ENI received radiotherapy to either supraclavicular (n = 54) or celiac (n = 19) lymphatics. Fifty-six patients (57%) received chemotherapy with paclitaxel plus cisplatin. The 3-year progression-free survival, overall survival, and patterns of failure were analyzed. Distant nodal recurrence was classified into M1a and M1b regions. A separate analysis using matched cases was conducted. Results: The median follow-up was 38 months. There were no differences in pathological complete response rate (p = 0.12), perioperative mortality rate (p = 0.48), or delayed Grade 3 or greater cardiopulmonary toxicities (p = 0.44), between the groups. More patients in the non-ENI group had M1a failure than in the ENI group, with 3-year rates of 11% and 3%, respectively (p = 0.05). However, the 3-year isolated distant nodal (M1a + M1b) failure rates were not different (ENI, 10%; non-ENI, 14%; p = 0.29). In multivariate analysis, pathological nodal status was the only independent prognostic factor associated with overall survival (hazard ratio = 1.78, p = 0.045). The 3-year overall survival and progression-free survival were 45% and 45%, respectively, in the ENI group, and 52% and 43%, respectively, in the non-ENI group (p = 0.31 and 0.89, respectively). Matched cases analysis did not show a statistical difference in outcomes between the groups. Conclusions: ENI reduced the M1a failure rate but was not associated with improved outcomes in patients undergoing preoperative CCRT for esophageal

  13. Use of the flexible sigmoidoscope in women with previous pelvic irradiation

    International Nuclear Information System (INIS)

    Sandler, R.S.; Varma, V.; Herbst, C.A. Jr.; Montana, G.S.; Rudnick, S.A.; Fowler, W.C. Jr.

    1982-01-01

    Pelvic irradiation has been reported to be a risk factor for colonic malignancy. We performed flexible sigmoidoscopy with serial pinch biopsies in 20 asymptomatic women treated with irradiation for cervical cancer more than 10 years ago in order to determine the feasibility of the technique and to detect late radiation effects. The examination was well tolerated by 14 (70%) of the patients, and the instrument was passed to 40 cm in 14 (74%) of 19 women. Abnormal mucosal or vascular changes were found in 12 (60%) and nonspecific microscopic abnormalities were seen in 18 (90%) of the 20 women

  14. Comparison of the kidney dose between supine and prone position for pelvic and periaortic irradiation

    International Nuclear Information System (INIS)

    Mison, Chun; Haejin, Kang; Juree, Kim; Heesuk, Ryu; Hyunsoo, Shin

    1996-01-01

    We compared the doses received by the kidney in supine and prone positions for pelvic and periaortic irradiation. Kidney locations were verified by CT images taken with patients in the same position as during the treatment. Due to the shift of the kidney anteriorly during prone position, treatment in supine position delivered a much lower dose to most of the kidney than treatment in the prone position. Therefore, for periaortic irradiation treatment, the supine position should be considered to minimize the dose to the kidneys, even though the prone position with a belly board can reduce the dose to the small bowel

  15. Adjuvant radiotherapy for uterine papillary serous carcinoma: Whole abdominopelvic or pelvic irradiation?

    International Nuclear Information System (INIS)

    Casey, W.; Chen, Y.; DuBeshter, B.; Angel, C.; Dawson, A.; Smudzin, T.; Rubin, P.

    1996-01-01

    Objective: The optimum adjuvant therapy for uterine papillary serous carcinoma (UPSC), a rare but clinically aggressive histologic variant of endometrial carcinoma, is a controversial issue. UPSC behaves in a pattern that resembles the papillary serous carcinoma of the ovary with a tendency to spread to the peritoneal surfaces. Whole abdominopelvic irradiation (WAI) has been advocated but it remains unclear if adjuvant pelvic irradiation alone is sufficient for early stage UPSC. We reviewed our experience in the adjuvant radiation treatment for UPSC treated at our institution. Materials and Methods: Between 1985 and 1995, a series of 351 cases of endometrial carcinoma were referred to the department of Radiation Oncology. There were a total of 26 UPSC cases with 25 medical records available for review. Except for one case which received irradiation alone, the remaining 24 cases were all surgically staged with TAH/BSO. These patients were treated with WAI or pelvic irradiation with or without a vaginal cuff boost using brachytherapy. The irradiation treatment fields, dose, the local/regional and distant disease status at last follow-up were recorded. The medium follow-up interval was four years with a range of one to eight years. Kaplan-Meier plots for disease specific survival and local/regional disease free survival were obtained. Results: Of the 25 surgically staged UPSC patients, the stage distribution was as follows: 9 stage I, 4 stage II, 10 stage III, and 2 stage IVB. Twelve patients received WAI (4 stage I disease, and 8 stage III disease), while the remaining patients were treated with pelvic irradiation (XRT). 1.) 13 patients were alive without disease and 3 were alive with disease. Seven patients died of either distant metastasis or abdominal recurrence and two died of intercurrent disease (5 year disease specific survival for the whole group was 43%). Two of 17 patients with stages IIIA and below vs. five of 8 patients with stages IIIB and above died of

  16. Can involved-field irradiation replace elective nodal irradiation in chemoradiotherapy for esophageal cancer? A systematic review and meta-analysis.

    Science.gov (United States)

    Wang, Xiaoyue; Miao, Chuanwang; Chen, Zhen; Li, Wanhu; Yuan, Shuanghu; Yu, Jinming; Hu, Xudong

    2017-01-01

    Chemoradiotherapy is the most common treatment for inoperable esophageal cancer. However, there is no consensus on the delineation of the clinical target volume. Elective nodal irradiation (ENI) is recommended for inoperable esophageal cancer. A few studies have reported a decrease in the incidence of radiation-related toxicity of involved-field irradiation (IFI) for esophageal cancer. A systematic review and pooled analysis were performed to determine whether IFI in definitive chemoradiotherapy was more beneficial than ENI for esophageal cancer. The results showed no significant differences in the overall survival and local control rates between the IFI and ENI arms. Meanwhile, the incidences of esophageal and lung toxicities were significantly decreased in the IFI arm. These results suggest that IFI is a feasible treatment option for locally advanced esophageal cancer, especially to minimize irradiation-related toxicity.

  17. Fluorodeoxyglucose positron emission tomography?computed tomography in evaluation of pelvic and para-aortic nodal involvement in early stage and operable cervical cancer: Comparison with surgicopathological findings

    OpenAIRE

    Bansal, Vandana; Damania, Kaizad; Sharma, Anshu Rajnish

    2011-01-01

    Introduction: Nodal metastases in cervical cancer have prognostic implications. Imaging is used as an adjunct to clinical staging for evaluation of nodal metastases. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has an advantage of superior resolution of its CT component and detecting nodal disease based on increased glycolytic activity rather than node size. But there are limited studies describing its limitations in early stage cervical cancers. Objectiv...

  18. Effects of pelvic telecobalt irradiation on gonadotropin secretin

    International Nuclear Information System (INIS)

    Pfenninger, R.

    1978-01-01

    The pitnitary reaction in women operated according to Wertheim who had menstruated regularly was investigated during telecobalt irradiation. The pitnitary reaction was observed with the aid of the gonadotropin releasing factor. A dose of 25 mcg RH-LH was applied. Releasing factor examinations were carried out before exposure with functioning ovaries, after a dose of 2000 R (i.e., after 10 exposures), and after 6000 R. In the meantime, separate gonadotropin examinations were carried out continuously. A FSH reaction was observed already after 14 days, and the values were raised to almost menopause values. After this, the FSH increased further, while the LH reaction was not observed until much later. The investigation suggests an interrelation between follicle apparatus and FSH, oestrogens and LH. (orig./AJ) [de

  19. Efficacy of elective nodal irradiation in skin squamous cell carcinoma of the face, ears, and scalp

    OpenAIRE

    Wray, Justin; Amdur, Robert J.; Morris, Christopher G.; Werning, John; Mendenhall, William M.

    2015-01-01

    Background In patients at high risk for regional node metastasis from squamous cell carcinoma (SCC) of the skin of the face, ear, or scalp, radiotherapy to the regional nodes is an alternative to parotid or neck surgery. Data on the efficacy of elective nodal radiotherapy in this setting are scarce such that there is no publication specifically addressing the subject. The purpose of our study is to fill this void in the skin cancer literature. Methods This is a single-institution study of out...

  20. A quality control study of the accuracy of patient positioning in irradiation of pelvic fields

    International Nuclear Information System (INIS)

    Creutzberg, Carien L.; Althof, Vincent G.M.; Hoog, Marjan de; Visser, Andries G.; Huizenga, Henk; Wijnmaalen, Arendjan; Levendag, Peter C.

    1996-01-01

    Purpose: Determining and improving the accuracy of patient positioning in pelvic fields. Methods and Materials: Small pelvic fields were studied in 16 patients treated for urological cancers using a three-field isocentric technique. Large pelvic fields were studied in 17 gynecological cancer patients treated with anterior and posterior (AP-PA) parallel opposed fields. Quantitative analysis of 645 megavolt images and comparison to 82 simulation images were carried out. Results: Small pelvic fields: for the position of the patient in the field, standard deviations of the difference between simulation (SIM) and treatment (MV) images were 3.4 mm in the lateral direction, 5.3 mm in the cranio-caudal direction, and 4.8 mm in the ventro-dorsal direction. Alterations in the positioning technique were made and tested. Large pelvic fields: differences between simulation and treatment images for the position of the patient in the field were 4 mm [1 standard deviation (SD)] in the lateral direction and 6.5 mm in the cranio-caudal direction. A systematic shift of the treatment field in the cranial direction had occurred in the majority of patients. A positioning technique using laser lines and marking of the caudal field border was shown to be more accurate. Conclusion: Studies of positioning accuracy in routine irradiation techniques are needed to obtain data for definition of the margins for each treatment site at each institution. Random variations should be kept at a minimum by monitoring and improving positioning techniques. Treatment verification by megavolt imaging or film should be used to detect and correct systematic variations early in the treatment series

  1. Diarrhea following whole pelvis irradiation in female pelvic cancer

    International Nuclear Information System (INIS)

    Sakurai, Tomoyasu; Moriya, Hiroshi; Hareyama, Masato; Nishio, Masamichi

    1975-01-01

    Investigations were made on the following points which were possible factors in the appearance of diarrhea during irradiation of the whole pelvis for uterine cancer: (a) daily dose of 200 and 180 rads, (b) age, (c) radical operation for uterine cancer, (d) previous history of abdominal operation, (e) disease stage of II or III, and (f) grade of infiltration of the rectum with cancer cells. Results thereby obtained are summarized as follows: 1) A significant difference between the dose of 200 and 180 rads in causing diarrhea was found only in patients receiving radiation therapy alone, without a previous history of abdominal operation. 2) Patients who underwent a radical operation for uterine cancer showed a significantly higher incidence of diarrhea than those without such an operation. 3) The age of patients, previous history of abdominal operation, and grade of infiltration of cancer cells into the rectum had almost no effect on the incidence of diarrhea. 4) There was no significant difference in the frequency of diarrhea between stage II and III, although the higher incidence recorded for the latter group was between a 10 and 20% level of significance. (auth.)

  2. Risk of isolated nodal failure for non-small cell lung cancer (NSCLC) treated with the elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT) techniques - A retrospective analysis

    International Nuclear Information System (INIS)

    Kepka, Lucyna; Bujko, Krzysztof; Zolciak-Siwinska, Agnieszka

    2008-01-01

    Purpose. To estimate retrospectively the rate of isolated nodal failures (INF) in NSCLC patients treated with the elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT). Materials/methods. One hundred and eighty-five patients with I-IIIB stage treated with 3D-CRT in consecutive clinical trials differing in an extent of the ENI were analyzed. According to the extent of the ENI, two groups were distinguished: extended (n=124) and limited (n=61) ENI. INF was defined as regional nodal failure occurring without local progression. Cumulative Incidence of INF (CIINF) was evaluated by univariate and multivariate analysis with regard to prognostic factors. Results. With a median follow up of 30 months, the two-year actuarial overall survival was 35%. The two-year CIINF rate was 12%. There were 16 (9%) INF, eight (6%) for extended and eight (13%) for limited ENI. In the univariate analysis bulky mediastinal disease (BMD), left side, higher N stage, and partial response to RT had a significant negative impact on the CIINF. BMD was the only independent predictor of the risk of incidence of the INF (p=0.001). Conclusions. INF is more likely to occur in case of more advanced nodal status

  3. Risk of isolated nodal failure for non-small cell lung cancer (NSCLC) treated with the elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT) techniques--a retrospective analysis.

    Science.gov (United States)

    Kepka, Lucyna; Bujko, Krzysztof; Zolciak-Siwinska, Agnieszka

    2008-01-01

    To estimate retrospectively the rate of isolated nodal failures (INF) in NSCLC patients treated with the elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT). One hundred and eighty-five patients with I-IIIB stage treated with 3D-CRT in consecutive clinical trials differing in an extent of the ENI were analyzed. According to the extent of the ENI, two groups were distinguished: extended (n = 124) and limited (n = 61) ENI. INF was defined as regional nodal failure occurring without local progression. Cumulative Incidence of INF (CIINF) was evaluated by univariate and multivariate analysis with regard to prognostic factors. With a median follow up of 30 months, the two-year actuarial overall survival was 35%. The two-year CIINF rate was 12%. There were 16 (9%) INF, eight (6%) for extended and eight (13%) for limited ENI. In the univariate analysis bulky mediastinal disease (BMD), left side, higher N stage, and partial response to RT had a significant negative impact on the CIINF. BMD was the only independent predictor of the risk of incidence of the INF (p = 0.001). INF is more likely to occur in case of more advanced nodal status.

  4. Transverse colon conduit urinary diversion in patients treated with very high dose pelvic irradiation

    International Nuclear Information System (INIS)

    Ravi, R.; Dewan, A.K.; Pandey, K.K.

    1994-01-01

    Urinary diversion may be required in patients receiving pelvic irradiation for gynaecological or genitourinary cancers either as part of a planned or salvage surgical procedure or for urological complications of irradiation. Records were reviewed for 30 such patients who underwent transverse colon conduit as a primary form of urinary diversion. Most of the conduits were constructed using refluxing ureterocolic anastomoses with stents. The results showed no operative mortality. Although the procedure was associated with a complication rate of 37% and a re-operation rate of 20%, there were no bowel or urinary anastomotic leaks. The operation could be safely performed on patients with renal failure, with 83% of such patients showing normal or improved serum creatinine levels post operatively. The advantages of transverse colon conduit urinary diversion are the use of non-irradiated bowel and ureters for diversion. It is recommended as a primary form of urinary diversion in these high risk cases. (Author)

  5. Evaluation of set-of errors in pelvic irradiation with electronic portal imaging device

    International Nuclear Information System (INIS)

    Wu Xiaoying; Zhang Zhen; Wang Wenchao; Ren Jun; Guo Xiaomei; Lu Huizhong

    2007-01-01

    Objective: Evaluate the systematic and random set-up error in the pelvic irradiation u- sing electronic portal imaging device(EPID) to provide institution-specific margin for PTV design in pelvic cancer treatment planning with 3D conformal therapy and/or IMRT. Methods: From May to August 2005, twelve patients who received pelvic irradiation, were involved in this study. CT simulations were performed and DRRs were generated as the reference images. Ant-post and lateral portal images were taken daily, and total of 244 sets of EPID images were collected for the whole group. The translational shifts along right-left, superior-inferior and anterior-posterior directions were calculated with aligning the pelvic bony structures on the DRRs and electronic portal images. The systematic and random setup errors were evaluated based on the 244 sets of data. PTV margin was assessed assuming target rotation was negligible. Results: In the right- left (R-L), superior-inferior (S-I) and anterior-posterior (A-P) directions, the maximum shifts were 9.9, 14.0 and 21.1 mm and the systematic setup errors were 0.5, 0.2 and 2.3 mm respectively. For all 244 sets of data in this study, the frequency of the shift larger than 10 mm were 0% (R-L), 1% (S-I) and 3% (A -P); and in R-L and S-I direction, 92% and 91% of the times the shift was smaller than 5 mm. However, only 79% of the times the A-P shift was less than 5 mm. Conclusions: It is suggested in this study that in order to achieve a target coverage of better than 95% of the times throughout the pelvic irradiation in our institution, a 5 mm PTV margin in right-left and superior-inferior directions is required, however, the anterior-posterior margin needs to be increased to at least 10 mm. One needs to be cautious though when applying the PTV margin derived from small sample of patient population to individual patient. (authors)

  6. Pathological response of locally advanced rectal cancer to preoperative chemotherapy without pelvic irradiation.

    Science.gov (United States)

    Bensignor, T; Brouquet, A; Dariane, C; Thirot-Bidault, A; Lazure, T; Julié, C; Nordlinger, B; Penna, C; Benoist, S

    2015-06-01

    Pathological response to chemotherapy without pelvic irradiation is not well defined in rectal cancer. This study aimed to evaluate the objective pathological response to preoperative chemotherapy without pelvic irradiation in middle or low locally advanced rectal cancer (LARC). Between 2008 and 2013, 22 patients with middle or low LARC (T3/4 and/or N+ and circumferential resection margin rectal resection after preoperative chemotherapy. The pathological response of rectal tumour was analysed according to the Rödel tumour regression grading (TRG) system. Predictive factors of objective pathological response (TRG 2-4) were analysed. All patients underwent rectal surgery after a median of six cycles of preoperative chemotherapy. Of these, 20 (91%) had sphincter saving surgery and an R0 resection. Twelve (55%) patients had an objective pathological response (TRG 2-4), including one complete response. Poor response (TRG 0-1) to chemotherapy was noted in 10 (45%) patients. In univariate analyses, none of the factors examined was found to be predictive of an objective pathological response to chemotherapy. At a median follow-up of 37.2 months, none of the 22 patients experienced local recurrence. Of the 19 patients with Stage IV rectal cancer, 15 (79%) had liver surgery with curative intent. Preoperative chemotherapy without pelvic irradiation is associated with objective pathological response and adequate local control in selected patients with LARC. Further prospective controlled studies will address the question of whether it can be used as a valuable alternative to radiochemotherapy in LARC. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  7. Dosimetric evaluation of three adaptive strategies for prostate cancer treatment including pelvic lymph nodes irradiation.

    Science.gov (United States)

    Cantin, Audrey; Gingras, Luc; Lachance, Bernard; Foster, William; Goudreault, Julie; Archambault, Louis

    2015-12-01

    The movements of the prostate relative to the pelvic lymph nodes during intensity-modulated radiation therapy treatment can limit margin reduction and affect the protection of the organs at risk (OAR). In this study, the authors performed an analysis of three adaptive treatment strategies that combine information from both bony and gold marker registrations. The robustness of those treatments against the interfraction prostate movements was evaluated. A retrospective study was conducted on five prostate cancer patients with 7-13 daily cone-beam CTs (CBCTs). The clinical target volumes (CTVs) consisting of pelvic lymph nodes, prostate, and seminal vesicles as well as the OARs were delineated on each CBCT and the initial CT. Three adaptive strategies were analyzed. Two of these methods relied on a two-step patient positioning at each fraction. First step: a bony registration was used to deliver the nodal CTV prescription. Second step: a gold marker registration was then used either to (1) complete the dose delivered to the prostate (complement); (2) or give almost the entire prescription to the prostate with a weak dose gradient between the targets to compensate for possible motions (gradient). The third method (COR) used a pool of precalculated plans based on images acquired at previous treatment fractions. At each new fraction, a plan is selected from that pool based on the daily position of prostate center-of-mass. The dosimetric comparison was conducted and results are presented with and without the systematic shift in the prostate position on the CT planning. The adaptive strategies were compared to the current clinical standard where all fractions are treated with the initial nonadaptive plan. The minimum daily prostate D95% is improved by 2%, 9%, and 6% for the complement, the gradient, and the COR approaches, respectively, compared to the nonadaptive method. The average nodal CTV D95% remains constant across the strategies, except for the gradient approach

  8. Dosimetric evaluation of three adaptive strategies for prostate cancer treatment including pelvic lymph nodes irradiation

    International Nuclear Information System (INIS)

    Cantin, Audrey; Gingras, Luc; Archambault, Louis; Lachance, Bernard; Foster, William; Goudreault, Julie

    2015-01-01

    Purpose: The movements of the prostate relative to the pelvic lymph nodes during intensity-modulated radiation therapy treatment can limit margin reduction and affect the protection of the organs at risk (OAR). In this study, the authors performed an analysis of three adaptive treatment strategies that combine information from both bony and gold marker registrations. The robustness of those treatments against the interfraction prostate movements was evaluated. Methods: A retrospective study was conducted on five prostate cancer patients with 7–13 daily cone-beam CTs (CBCTs). The clinical target volumes (CTVs) consisting of pelvic lymph nodes, prostate, and seminal vesicles as well as the OARs were delineated on each CBCT and the initial CT. Three adaptive strategies were analyzed. Two of these methods relied on a two-step patient positioning at each fraction. First step: a bony registration was used to deliver the nodal CTV prescription. Second step: a gold marker registration was then used either to (1) complete the dose delivered to the prostate (complement); (2) or give almost the entire prescription to the prostate with a weak dose gradient between the targets to compensate for possible motions (gradient). The third method (COR) used a pool of precalculated plans based on images acquired at previous treatment fractions. At each new fraction, a plan is selected from that pool based on the daily position of prostate center-of-mass. The dosimetric comparison was conducted and results are presented with and without the systematic shift in the prostate position on the CT planning. The adaptive strategies were compared to the current clinical standard where all fractions are treated with the initial nonadaptive plan. Results: The minimum daily prostate D 95% is improved by 2%, 9%, and 6% for the complement, the gradient, and the COR approaches, respectively, compared to the nonadaptive method. The average nodal CTV D 95% remains constant across the strategies

  9. Involved-Field Radiotherapy versus Elective Nodal Irradiation in Combination with Concurrent Chemotherapy for Locally Advanced Non-Small Cell Lung Cancer: A Prospective Randomized Study

    Science.gov (United States)

    Chen, Ming; Bao, Yong; Ma, Hong-Lian; Wang, Jin; Wang, Yan; Peng, Fang; Zhou, Qi-Chao; Xie, Cong-Hua

    2013-01-01

    This prospective randomized study is to evaluate the locoregional failure and its impact on survival by comparing involved field radiotherapy (IFRT) with elective nodal irradiation (ENI) in combination with concurrent chemotherapy for locally advanced non-small cell lung cancer. It appears that higher dose could be delivered in IFRT arm than that in ENI arm, and IFRT did not increase the risk of initially uninvolved or isolated nodal failures. Both a tendency of improved locoregional progression-free survival and a significant increased overall survival rate are in favor of IFRT arm in this study. PMID:23762840

  10. Fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of pelvic and para-aortic nodal involvement in early stage and operable cervical cancer: comparison with surgicopathological findings

    International Nuclear Information System (INIS)

    Bansal, Vandana; Damania, Kaizad; Sharma, Anshu Rajnish

    2011-01-01

    Nodal metastases in cervical cancer have prognostic implications. Imaging is used as an adjunct to clinical staging for evaluation of nodal metastases. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has an advantage of superior resolution of its CT component and detecting nodal disease based on increased glycolytic activity rather than node size. But there are limited studies describing its limitations in early stage cervical cancers. We have done meta-analysis with an objective to evaluate the efficacy of FDG PET/CT and its current clinical role in early stage and operable cervical cancer. Studies in which FDG PET/CT was performed before surgery in patients with early stage cervical cancers were included for analysis. PET findings were confirmed with histopathological diagnosis rather than clinical follow-up. The current data suggest that FDG PET/CT is suboptimal in nodal staging in early stage cervical cancer

  11. Elective nodal irradiation (ENI) vs. involved field radiotherapy (IFRT) for locally advanced non-small cell lung cancer (NSCLC): A comparative analysis of toxicities and clinical outcomes

    International Nuclear Information System (INIS)

    Fernandes, Annemarie T.; Shen, Jason; Finlay, Jarod; Mitra, Nandita; Evans, Tracey; Stevenson, James; Langer, Corey; Lin, Lilie; Hahn, Stephen; Glatstein, Eli; Rengan, Ramesh

    2010-01-01

    Background: Elective nodal irradiation (ENI) and involved field radiotherapy (IFRT) are definitive radiotherapeutic approaches used to treat patients with locally advanced non-small cell lung cancer (NSCLC). ENI delivers prophylactic radiation to clinically uninvolved lymph nodes, while IFRT only targets identifiable gross nodal disease. Because clinically uninvolved nodal stations may harbor microscopic disease, IFRT raises concerns for increased nodal failures. This retrospective cohort analysis evaluates failure rates and treatment-related toxicities in patients treated at a single institution with ENI and IFRT. Methods: We assessed all patients with stage III locally advanced or stage IV oligometastatic NSCLC treated with definitive radiotherapy from 2003 to 2008. Each physician consistently treated with either ENI or IFRT, based on their treatment philosophy. Results: Of the 108 consecutive patients assessed (60 ENI vs. 48 IFRT), 10 patients had stage IV disease and 95 patients received chemotherapy. The median follow-up time for survivors was 18.9 months. On multivariable logistic regression analysis, patients treated with IFRT demonstrated a significantly lower risk of high grade esophagitis (Odds ratio: 0.31, p = 0.036). The differences in 2-year local control (39.2% vs. 59.6%), elective nodal control (84.3% vs. 84.3%), distant control (47.7% vs. 52.7%) and overall survival (40.1% vs. 43.7%) rates were not statistically significant between ENI vs. IFRT. Conclusions: Nodal failure rates in clinically uninvolved nodal stations were not increased with IFRT when compared to ENI. IFRT also resulted in significantly decreased esophageal toxicity, suggesting that IFRT may allow for integration of concurrent systemic chemotherapy in a greater proportion of patients.

  12. Elective nodal irradiation (ENI) vs. involved field radiotherapy (IFRT) for locally advanced non-small cell lung cancer (NSCLC): A comparative analysis of toxicities and clinical outcomes.

    Science.gov (United States)

    Fernandes, Annemarie T; Shen, Jason; Finlay, Jarod; Mitra, Nandita; Evans, Tracey; Stevenson, James; Langer, Corey; Lin, Lilie; Hahn, Stephen; Glatstein, Eli; Rengan, Ramesh

    2010-05-01

    Elective nodal irradiation (ENI) and involved field radiotherapy (IFRT) are definitive radiotherapeutic approaches used to treat patients with locally advanced non-small cell lung cancer (NSCLC). ENI delivers prophylactic radiation to clinically uninvolved lymph nodes, while IFRT only targets identifiable gross nodal disease. Because clinically uninvolved nodal stations may harbor microscopic disease, IFRT raises concerns for increased nodal failures. This retrospective cohort analysis evaluates failure rates and treatment-related toxicities in patients treated at a single institution with ENI and IFRT. We assessed all patients with stage III locally advanced or stage IV oligometastatic NSCLC treated with definitive radiotherapy from 2003 to 2008. Each physician consistently treated with either ENI or IFRT, based on their treatment philosophy. Of the 108 consecutive patients assessed (60 ENI vs. 48 IFRT), 10 patients had stage IV disease and 95 patients received chemotherapy. The median follow-up time for survivors was 18.9 months. On multivariable logistic regression analysis, patients treated with IFRT demonstrated a significantly lower risk of high grade esophagitis (Odds ratio: 0.31, p = 0.036). The differences in 2-year local control (39.2% vs. 59.6%), elective nodal control (84.3% vs. 84.3%), distant control (47.7% vs. 52.7%) and overall survival (40.1% vs. 43.7%) rates were not statistically significant between ENI vs. IFRT. Nodal failure rates in clinically uninvolved nodal stations were not increased with IFRT when compared to ENI. IFRT also resulted in significantly decreased esophageal toxicity, suggesting that IFRT may allow for integration of concurrent systemic chemotherapy in a greater proportion of patients. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  13. Ovarian function following pelvic irradiation in prepubertal and pubertal girls and young adult women

    Energy Technology Data Exchange (ETDEWEB)

    Schuck, A.; Hamelmann, V. [University Hospital Muenster (Germany). Dept. of Radiotherapy; Braemswig, J.H. [University Hospital Muenster (DE). Dept. of Pediatrics] [and others

    2005-08-01

    Purpose: To analyze the effect of pelvic radiotherapy on ovarian function in prepubertal and pubertal girls and young adult women. Patients and methods: In a retrospective monoinstitutional analysis, patients <30 years of age at diagnosis were included who had been irradiated between 1979 and 1998. The main tumor types were Hodgkin's disease (38%), Erwing's sarcoma (20%) and nephroblastoma (11%). Patients were classified into three groups according to the position of the ovary in relation to the radiation portals. Group 1 was defined by direct irradiation of both ovaries. Group 2 patients were included with both ovaries potentially located in the radiation portals. In group 3, at least one ovary was not directly irradiated. The median follow-up was 128 months. Results: 16 of 55 analyzed patients were categorized in group 1. In ten of these patients, hormone status was evaluable. The ovarian doses were {>=}15 Gy. Except for one patient treated with 15 Gy all developed hormone failure. Eight of 14 patients of group 2 were evaluable. Seven of these patients developed ovarian failure. 19 of 24 patients in group 3 were evaluable. Nine of these patients developed ovarian failure. The observed difference in the rate of ovarian failure between the groups is statistifcally significant (p=0.045). Conclusion: All patients receiving >15 Gy to the ovaries developed hormone failure. In one case of a patient receiving an ovarian dose of 15 Gy, hormone failure was not found. In case of pelvic irradiation excluding at least one ovary, approximately half of the patients developed ovarian dysfunction, probably also due to the effects of polychemotherapy. (orig.)

  14. Effect of pelvic irradiation on the bone mineral content of lumbar spine in cervical cancer

    International Nuclear Information System (INIS)

    Youn, S. M.; Choi, T. J.; Koo, E. S.; Kim, O. B.; Lee, S. M.; Suh, S. J.

    1997-01-01

    To evaluate the loss of bone mineral contents(BMC) in lumbar spine within the radiation field for cervical cancer treatment, BMC in the irradiated patient group was compared with that of a normal control group. Measurements of BMC in the trabecular bone in lumbar spines(L3-L5) were performed in the both patient and normal control groups. Investigators used dual-energy quantitative computerized tomography(DEQCD) using photon energy of 120 and 80kVp. The numbers of patient and control groups were 43 in each with age distribution of fifth to seventh decade of women. The numbers of control group were 22 in fifth, 10 in sixth, and 11 in seventh decade, those of patient group were 14 in fifth, 14 in sixth, and 15 in seventh decade of women. The radiation field was extended to L5 spine for pelvic irradiation with 45-54Gy of external radiation dose and 30Gy of high dose rate brachytherapy in cervical cancer. The BMC is decreased as increasing age in both control and patient groups. BMC in lumbar spine of patient group was decreased by about 13% to 40% maximally. The BMC of L3 and L4 a region that is out of a radiation field for the patient group demonstrated 119.5 ±30.6, 117.0 ±31.7 for fifth, 83.3 ± 37.8, 88.3 ± 46.8 for sixth and 61.5 ± 18.3, 56.2 ± 26.6 mg/cc for seventh. Contrasted by the normal control group has shown 148.0 ± 19.9, 153.2 ± 23.2 for fifth, 96.1 ± 30.2, 105.6 ± 26.5 for sixth and 73.9 ± 27.9, 77.2 ± 27.2 mg/cc for seventh decade, respectively. The BMC of patient group was decreased as near the radiation field, while the lower lumbar spine has shown more large amounts of BMC in the normal control group. In particular, the BMC of L5 within the radiation field was significantly decreased to 33%, 31%, 40% compared with the control group of the fifth, sixth and seventh decades, respectively. The pelvic irradiation in cervical cancer has much effected on the loss of bone mineral content of lumbar spine within the radiation field, as the lower

  15. Techniques and usefulness of para-aortic nodal irradiation in carcinoma of the cervix

    International Nuclear Information System (INIS)

    Nori, D.

    1987-01-01

    In this chapter the authors evaluate irradiation of para-aortic node metastasis in carcinoma of the cervix and the outcome of patients who have undergone such treatment. They also present an approach designed to minimize complications of investigation and treatment. The technical details of surgical procedure and preliminary analysis of these data have been published earlier

  16. Fluorodeoxyglucose positron emission tomography–computed tomography in evaluation of pelvic and para-aortic nodal involvement in early stage and operable cervical cancer: Comparison with surgicopathological findings

    Science.gov (United States)

    Bansal, Vandana; Damania, Kaizad; Sharma, Anshu Rajnish

    2011-01-01

    Introduction: Nodal metastases in cervical cancer have prognostic implications. Imaging is used as an adjunct to clinical staging for evaluation of nodal metastases. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has an advantage of superior resolution of its CT component and detecting nodal disease based on increased glycolytic activity rather than node size. But there are limited studies describing its limitations in early stage cervical cancers. Objective: We have done meta-analysis with an objective to evaluate the efficacy of FDG PET/CT and its current clinical role in early stage and operable cervical cancer. Materials and Methods: Studies in which FDG PET/CT was performed before surgery in patients with early stage cervical cancers were included for analysis. PET findings were confirmed with histopathological diagnosis rather than clinical follow-up. FDG PET/CT showed lower sensitivity and clinically unacceptable negative predictive value in detecting nodal metastases in early stage cervical cancer and therefore, can not replace surgicopathological staging. False negative results in presence of microscopic disease and sub-centimeter diseased nodes are still the area of concern for metabolic imaging. However, these studies are single institutional and performed in a small group of patients. There is enough available evidence of clinical utility of FDG PET/CT in locally advanced cervical cancer. But these results can not be extrapolated for early stage disease. Conclusion: The current data suggest that FDG PET/CT is suboptimal in nodal staging in early stage cervical cancer. PMID:23559711

  17. Prognostic Modeling in Pathologic N1 Breast Cancer Without Elective Nodal Irradiation After Current Standard Systemic Management.

    Science.gov (United States)

    Yu, Jeong Il; Park, Won; Choi, Doo Ho; Huh, Seung Jae; Nam, Seok Jin; Kim, Seok Won; Lee, Jeong Eon; Kil, Won Ho; Im, Young-Hyuck; Ahn, Jin Seok; Park, Yeon Hee; Cho, Eun Yoon

    2015-08-01

    This study was conducted to establish a prognostic model in patients with pathologic N1 (pN1) breast cancer who have not undergone elective nodal irradiation (ENI) under the current standard management and to suggest possible indications for ENI. We performed a retrospective study with patients with pN1 breast cancer who received the standard local and preferred adjuvant chemotherapy treatment without neoadjuvant chemotherapy and ENI from January 2005 to June 2011. Most of the indicated patients received endocrine and trastuzumab therapy. In 735 enrolled patients, the median follow-up period was 58.4 months (range, 7.2-111.3 months). Overall, 55 recurrences (7.4%) developed, and locoregional recurrence was present in 27 patients (3.8%). Recurrence-free survival was significantly related to lymphovascular invasion (P = .04, hazard ratio [HR], 1.83; 95% confidence interval [CI], 1.03-2.88), histologic grade (P = .03, HR, 2.57; 95% CI, 1.05-6.26), and nonluminal A subtype (P = .02, HR, 3.04; 95% CI, 1.23-7.49) in multivariate analysis. The prognostic model was established by these 3 prognostic factors. Recurrence-free survival was less than 90% at 5 years in cases with 2 or 3 factors. The prognostic model has stratified risk groups in pN1 breast cancer without ENI. Patients with 2 or more factors should be considered for ENI. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Three-dimensional conformal radiation may deliver considerable dose of incidental nodal irradiation in patients with early stage node-negative non-small cell lung cancer when the tumor is large and centrally located

    International Nuclear Information System (INIS)

    Zhao Lujun; Chen Ming; Haken, Randall ten; Chetty, Indrin; Chapet, Olivier; Hayman, James A.; Kong Fengming

    2007-01-01

    Background and purpose: To determine the dose to regional nodal stations in patients with T 1-3 N 0 M 0 non-small cell lung cancer (NSCLC) treated with three-dimensional conformal radiation therapy (3DCRT) without intentional elective nodal irradiation (ENI). Materials and methods: Twenty-three patients with medically inoperable T 1-3 N 0 M 0 NSCLC were treated with 3DCRT without ENI. Hilar and mediastinal nodal regions were contoured on planning CT. The prescription dose was normalized to 70 Gy. Equivalent uniform dose (EUD) and other dosimetric parameters (e.g., V 40 ) were calculated for each nodal station. Results: The median EUD for the whole group ranged from 0.4 to 4.4 Gy for all elective nodal regions. Gross tumor volume (GTV) and the relationship between GTV and hilum were significantly correlated with irradiation dose to ipsilateral hilar nodal regions (P 3 (diameter ∼ 4 cm) and or having any overlap with hilum, the median EUDs were 9.6, 22.6, and 62.9 Gy for ipsilateral lower paratracheal, subcarinal, and ipsilateral hilar regions, respectively. The corresponding median V 40 were 32.5%, 39.3%, and 97.6%, respectively. Conclusions: Although incidental nodal irradiation dose is low in the whole group, the dose to high-risk nodal regions is considerable in patients with T 1-3 N 0 NSCLC when the primary is large and/or centrally located

  19. SU-F-P-52: A Meta-Analysis of Controlled Clinical Trials Comparing Elective Nodal Irradiation with Involved-Field Irradiation for Conformal Or Intensity-Modulated Radiotherapy in Patients with Esophageal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bai, W; Zhang, R; Zhou, Z; Qiao, X [The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei (China)

    2016-06-15

    Purpose: To compare elective nodal irradiation with involved-field irradiation for three-dimensional conformal radiotherapy or intensity-modulated radiotherapy in patients with esophageal cancer by a metaanalysis. Methods: Wanfang, CNKI, VIP, CBM databases, PubMed, Embase and Cochrane Library were searched to identify the controlled clinical trials of elective nodal irradiation with involved-field irradiation for three-dimensional conformal radiotherapy or intensity-modulated radiotherapy in patients with esophageal cancer. The obtained data were analyzed using Stata 11.0. The difference between two groups was estimated by calculating the odds ratio (OR) with 95% confidence interval (95% CI). Results: A total of 12 controlled clinical trials involving 1095 esophageal cancer patients, which were selected according to inclusion and exclusion criteria, were included in this meta-analysis. The meta-analysis showed that the elective nodal irradiation group reduced the rates of out-field failure comparing with involved-field irradiation group (OR=3.727, P=0.007). However, the rates of ≥grades 3 acute radiation pneumonitis and esophagitis were significantly higher in the elective nodal irradiation group than in the involved-field irradiation group (OR=0.348, P=0.001, OR=0.385, P=0.000). 1-, 2-, 3-year local control rates (OR=0.966, P=0.837, OR=0.946, P=0.781; OR=0.732P=0.098) and 1-, 3-, 5-year survival rates were similar in the two groups ( OR=0.966, P=0.837; OR=0.946, P=0.781; OR=0.732, P=0.098; OR=0.952, P=0.756; OR=1.149, P=0.422; OR=0.768, P=0.120). It is the same with the rates of distant metastasis (OR=0.986, P=0.937). Conclusion: Compared with involved-field irradiation, the elective nodal irradiation can reduce the rates of out-field failure for three-dimensional conformal radiotherapy or intensity-modulated radiotherapy in patients with esophageal cancer. However, its advantage of local control and survival rates is not obvious and it increases the incidence

  20. Involved field radiotherapy (IFRT) versus elective nodal irradiation (ENI) for locally advanced non-small cell lung cancer: a meta-analysis of incidence of elective nodal failure (ENF).

    Science.gov (United States)

    Li, Ruijian; Yu, Liang; Lin, Sixiang; Wang, Lina; Dong, Xin; Yu, Lingxia; Li, Weiyi; Li, Baosheng

    2016-09-21

    The use of involved field radiotherapy (IFRT) has generated concern about the increasing incidence of elective nodal failure (ENF) in contrast to elective nodal irradiation (ENI). This meta-analysis aimed to provide more reliable and up-to-date evidence on the incidence of ENF between IFRT and ENI. We searched three databases for eligible studies where locally advanced non-small cell lung cancer (NSCLC) patients received IFRT or ENI. Outcome of interest was the incidence of ENF. The fixed-effects model was used to pool outcomes across the studies. There were 3 RCTs and 3 cohort studies included with low risk of bias. There was no significant difference in incidence of ENF between IFRT and ENI either among RCTs (RR = 1.38, 95 % CI: 0.59-3.25, p = 0.46) or among cohort studies (RR = 0.99, 95 % CI: 0.46-2.10, p = 0.97). There was also no significant difference in incidence of ENF between IFRT and ENI when RCTs and cohort studies were combined (RR = 1.15, 95 % CI: 0.65-2.01, p = 0.64). I 2 of test for heterogeneity was 0 %. This meta-analysis provides more reliable and stable evidence that there is no significant difference in incidence of ENF between IFRT and ENI.

  1. Long-term results of high-dose conformal radiotherapy for patients with medically inoperable T1-3N0 non-small-cell lung cancer: Is low incidence of regional failure due to incidental nodal irradiation?

    International Nuclear Information System (INIS)

    Chen Ming; Hayman, James A.; Haken, Randall K. ten; Tatro, Daniel; Fernando, Shaneli; Kong, F.-M.

    2006-01-01

    Purpose: To report the results of high-dose conformal irradiation and examine incidental nodal irradiation and nodal failure in patients with inoperable early-stage non-small-cell lung cancer (NSCLC). Methods and Materials: This analysis included patients with inoperable CT-staged T1-3N0M0 NSCLC treated on our prospective dose-escalation trial. Patients were treated with radiation alone (total dose, 63-102.9 Gy in 2.1-Gy daily fractions) with a three-dimensional conformal technique without intentional nodal irradiation. Bilateral highest mediastinal and upper/lower paratracheal, prevascular and retrotracheal, sub- and para-aortic, subcarinal, paraesophageal, and ipsilateral hilar regions were delineated individually. Nodal failure and doses of incidental irradiation were studied. Results: The potential median follow-up was 104 months. For patients who completed protocol treatment, median survival was 31 months. The actuarial overall survival rate was 86%, 61%, 43%, and 21% and the cause-specific survival rate was 89%, 70%, 53%, and 35% at 1, 2, 3, and 5 years, respectively. Weight loss (p = 0.008) and radiation dose in Gy (p = 0.013) were significantly associated with overall survival. In only 22% and 13% of patients examined did ipsilateral hilar and paratracheal (and subaortic for left-sided tumor) nodal regions receive a dose of ≥40 Gy, respectively. Less than 10% of all other nodal regions received a dose of ≥40 Gy. No patients failed initially at nodal sites. Conclusions: Radiation dose is positively associated with overall survival in patients with medically inoperable T1-3N0 NSCLC, though long-term results remain poor. The nodal failure rate is low and does not seem to be due to high-dose incidental irradiation

  2. 14C-lactose breath tests during pelvic radiotherapy: the effect of the amount of small bowel irradiated

    International Nuclear Information System (INIS)

    Weiss, R.G.; Stryker, J.A.

    1982-01-01

    Thirty patients who were undergoing pelvic radiotherapy had 14 C-lactose breath tests performed in the first and fifth weeks of treatment. In Group I (21 patients), a significant portion of the small intestine was irradiated, and in Group II (9 patients), only a small portion of the small intestine was irradiated. In Group I, the average reductions in the excretion of ingested 14 C between the first- and fifth-week tests were 41.5% at 1/2 hour postingestion (p 0.05). The data suggest that lactose malabsorption is a factor in the etiology of the nausea, vomiting, and diarrhea experienced by patients who are undergoing pelvic radiotherapy, and that the amount of bowel included in the treatment volume significantly influences the degree of malabsorption

  3. SU-F-T-437: 3 Field VMAT Technique for Irradiation of Large Pelvic Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Stakhursky, V [Radiation Oncology, Norwalk Hospital, Norwalk, CT (United States)

    2016-06-15

    Purpose: VMAT treatment planning for large pelvic volume irradiation could be suboptimal due to inability of Varian linac to split MLC carriage during VMAT delivery for fields larger than 14.5cm in X direction (direction of leaf motion). We compare the dosimetry between 3 VMAT planning techniques, two 2-arc field techniques and a 3-arc field technique: a) two small in X direction (less than 14.5cm) arc fields, complementing each other to cover the whole lateral extent of target during gantry rotation, b) two large arc fields, each covering the targets completely during the rotation, c) a 3 field technique with 2 small in X direction arcs and 1 large field covering whole target. Methods: 5 GYN cancer patients were selected to evaluate the 3 VMAT planning techniques. Treatment plans were generated using Varian Eclipse (ver. 11) TPS. Dose painting technique was used to deliver 5300 cGy to primary target and 4500 cGy to pelvic/abdominal node target. All the plans were normalized so that the prescription dose of 5300 cGy covered 95% of primary target volume. PTV and critical structures DVH curves were compared to evaluate all 3 planning techniques. Results: The dosimetric differences between the two 2-arc techniques were minor. The small field 2-arc technique showed a colder hot spot (0.4% averaged), while variations in maximum doses to critical structures were statistically nonsignificant (under 1.3%). In comparison, the 3-field technique demonstrated a colder hot spot (1.1% less, 105.8% averaged), and better sparing of critical structures. The maximum doses to larger bowel, small bowel and gluteal fold were 3% less, cord/cauda sparing was 4.2% better, and bladder maximum dose was 4.6% less. The differences in maximum doses to stomach and rectum were statistically nonsignificant. Conclusion: 3-arc VMAT technique for large field irradiation of pelvis demonstrates dosimetric advantages compared to 2-arc VMAT techniques.

  4. Treatment of Urethral Strictures from Irradiation and Other Nonsurgical Forms of Pelvic Cancer Treatment

    Science.gov (United States)

    Khourdaji, Iyad; Parke, Jacob; Burks, Frank

    2015-01-01

    Radiation therapy (RT), external beam radiation therapy (EBRT), brachytherapy (BT), photon beam therapy (PBT), high intensity focused ultrasound (HIFU), and cryotherapy are noninvasive treatment options for pelvic malignancies and prostate cancer. Though effective in treating cancer, urethral stricture disease is an underrecognized and poorly reported sequela of these treatment modalities. Studies estimate the incidence of stricture from BT to be 1.8%, EBRT 1.7%, combined EBRT and BT 5.2%, and cryotherapy 2.5%. Radiation effects on the genitourinary system can manifest early or months to years after treatment with the onus being on the clinician to investigate and rule-out stricture disease as an underlying etiology for lower urinary tract symptoms. Obliterative endarteritis resulting in ischemia and fibrosis of the irradiated tissue complicates treatment strategies, which include urethral dilation, direct-vision internal urethrotomy (DVIU), urethral stents, and urethroplasty. Failure rates for dilation and DVIU are exceedingly high with several studies indicating that urethroplasty is the most definitive and durable treatment modality for patients with radiation-induced stricture disease. However, a detailed discussion should be offered regarding development or worsening of incontinence after treatment with urethroplasty. Further studies are required to assess the nature and treatment of cryotherapy and HIFU-induced strictures. PMID:26494994

  5. Treatment of Urethral Strictures from Irradiation and Other Nonsurgical Forms of Pelvic Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Iyad Khourdaji

    2015-01-01

    Full Text Available Radiation therapy (RT, external beam radiation therapy (EBRT, brachytherapy (BT, photon beam therapy (PBT, high intensity focused ultrasound (HIFU, and cryotherapy are noninvasive treatment options for pelvic malignancies and prostate cancer. Though effective in treating cancer, urethral stricture disease is an underrecognized and poorly reported sequela of these treatment modalities. Studies estimate the incidence of stricture from BT to be 1.8%, EBRT 1.7%, combined EBRT and BT 5.2%, and cryotherapy 2.5%. Radiation effects on the genitourinary system can manifest early or months to years after treatment with the onus being on the clinician to investigate and rule-out stricture disease as an underlying etiology for lower urinary tract symptoms. Obliterative endarteritis resulting in ischemia and fibrosis of the irradiated tissue complicates treatment strategies, which include urethral dilation, direct-vision internal urethrotomy (DVIU, urethral stents, and urethroplasty. Failure rates for dilation and DVIU are exceedingly high with several studies indicating that urethroplasty is the most definitive and durable treatment modality for patients with radiation-induced stricture disease. However, a detailed discussion should be offered regarding development or worsening of incontinence after treatment with urethroplasty. Further studies are required to assess the nature and treatment of cryotherapy and HIFU-induced strictures.

  6. Dose-volume effects for pelvic bone marrow in predicting hematological toxicity in prostate cancer radiotherapy with pelvic node irradiation.

    Science.gov (United States)

    Sini, Carla; Fiorino, Claudio; Perna, Lucia; Noris Chiorda, Barbara; Deantoni, Chiara Lucrezia; Bianchi, Marco; Sacco, Vincenzo; Briganti, Alberto; Montorsi, Francesco; Calandrino, Riccardo; Di Muzio, Nadia; Cozzarini, Cesare

    2016-01-01

    To prospectively identify clinical/dosimetric predictors of acute/late hematologic toxicity (HT) in chemo-naÏve patients treated with whole-pelvis radiotherapy (WPRT) for prostate cancer. Data of 121 patients treated with adjuvant/salvage WPRT were analyzed (static-field IMRT n=19; VMAT/Rapidarc n=57; Tomotherapy n=45). Pelvic bone marrow (BM) was delineated as ilium (IL), lumbosacral, lower and whole pelvis (WP), and the relative DVHs were calculated. HT was graded both according to CTCAE v4.03 and as variation in percentage relative to baseline. Logistic regression was used to analyze association between HT and clinical/DVHs factors. Significant differences (p<0.005) in the DVH of BM volumes between different techniques were found: Tomotherapy was associated with larger volumes receiving low doses (3-20 Gy) and smaller receiving 40-50 Gy. Lower baseline absolute values of WBC, neutrophils and lymphocytes (ALC) predicted acute/late HT (p ⩽ 0.001). Higher BM V40 was associated with higher risk of acute Grade3 (OR=1.018) or late Grade2 lymphopenia (OR=1.005). Two models predicting lymphopenia were developed, both including baseline ALC, and BM WP-V40 (AUC=0.73) and IL-V40+smoking (AUC=0.904) for acute/late respectively. Specific regions of pelvic BM predicting acute/late lymphopenia, a risk factor for viral infections, were identified. The 2-variable models including specific constraints to BM may help reduce HT. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Reduced radiation dose for elective nodal irradiation in node-negative anal cancer: back to the roots

    Energy Technology Data Exchange (ETDEWEB)

    Henkenberens, Christoph; Meinecke, Daniela; Bremer, Michael; Christiansen, Hans [Medizinische Hochschule Hannover, Hannover Medical School, Department of Radiation Oncology, Klinik fuer Strahlentherapie und Spezielle Onkologie, Hannover (Germany); Michael, Stoll [End- und Dickdarmzentrum Hannover, Hannover (Germany)

    2015-11-15

    Chemoradiation (CRT) is the standard of care in patients with node-positive (cN+) and node-negative (cN0) anal cancer. Depending on the tumor size (T-stage), total doses of 50-60 Gray (Gy) in daily fractions of 1.8-2.0 Gy are usually applied to the tumor site. Inguinal and iliac lymph nodes usually receive a dose of ≥ 45 Gy. Since 2010, our policy has been to apply a reduced total dose of 39.6 Gy to uninvolved nodal regions. This paper provides preliminary results of the efficacy and safety of this protocol. Overall, 30 patients with histologically confirmed and node-negative anal cancer were treated in our department from 2009-2014 with definitive CRT. Histology all cases showed squamous cell carcinoma. A total dose of 39.6 Gy [single dose (SD) 1.8 Gy] was delivered to the iliac/inguinal lymph nodes. The area of the primary tumor received 50-59.4 Gy, depending on the T-stage. In parallel with the irradiation, 5-fluorouracil (5-FU) at a dose of 1000 mg/m{sup 2} was administered by continuous intravenous infusion over 24 h on days 1-4 and 29-32, and mitomycin C (MMC) at a dose of 10 mg/m{sup 2} (maximum absolute dose 14 mg) was administered on days 1 and 29. The distribution of the tumor stages was as follows: T1, n = 8; T2, n = 17; T3 n = 3. Overall survival (OS), local control (LC) of the lymph nodes, colostomy-free survival (CFS), and acute and chronic toxicities were assessed. The median follow-up was 27.3 months (range 2.7-57.4 months). Three patients (10.0 %) died, 2 of cardiopulmonary diseases and one of liver failure, yielding a 3-year OS of 90.0 %. Two patients (6.7 %) relapsed early and received salvage colostomies, yielding a 3-year CFS of 93.3 %. No lymph node relapses were observed, giving a lymph node LC of 100 %. According to the Common Terminology Criteria for Adverse Events Version 4.0 (CTCAE V. 4.0), there were no grade IV gastrointestinal or genitourinary acute toxicities. Seven patients showed acute grade III perineal skin toxicity. Acute grade

  8. Whole-Pelvic Nodal Radiation Therapy in the Context of Hypofractionation for High-Risk Prostate Cancer Patients: A Step Forward

    International Nuclear Information System (INIS)

    Kaidar-Person, Orit; Roach, Mack; Créhange, Gilles

    2013-01-01

    Given the low α/β ratio of prostate cancer, prostate hypofractionation has been tested through numerous clinical studies. There is a growing body of literature suggesting that with high conformal radiation therapy and even with more sophisticated radiation techniques, such as high-dose-rate brachytherapy or image-guided intensity modulated radiation therapy, morbidity associated with shortening overall treatment time with higher doses per fraction remains low when compared with protracted conventional radiation therapy to the prostate only. In high-risk prostate cancer patients, there is accumulating evidence that either dose escalation to the prostate or hypofractionation may improve outcome. Nevertheless, selected patients who have a high risk of lymph node involvement may benefit from whole-pelvic radiation therapy (WPRT). Although combining WPRT with hypofractionated prostate radiation therapy is feasible, it remains investigational. By combining modern advances in radiation oncology (high-dose-rate prostate brachytherapy, intensity modulated radiation therapy with an improved image guidance for soft-tissue sparing), it is hypothesized that WPRT could take advantage of recent results from hypofractionation trials. Moreover, the results from hypofractionation trials raise questions as to whether hypofractionation to pelvic lymph nodes with a high risk of occult involvement might improve the outcomes in WPRT. Although investigational, this review discusses the challenging idea of WPRT in the context of hypofractionation for patients with high-risk prostate cancer

  9. Whole-Pelvic Nodal Radiation Therapy in the Context of Hypofractionation for High-Risk Prostate Cancer Patients: A Step Forward

    Energy Technology Data Exchange (ETDEWEB)

    Kaidar-Person, Orit [Division of Oncology, Rambam Health Care Campus, Haifa (Israel); Roach, Mack [Department of Radiation Oncology, University of California, San Francisco, San Francisco, California (United States); Créhange, Gilles, E-mail: gcrehange@cgfl.fr [Department of Radiation Oncology, Georges-François Leclerc Cancer Center, Dijon (France)

    2013-07-15

    Given the low α/β ratio of prostate cancer, prostate hypofractionation has been tested through numerous clinical studies. There is a growing body of literature suggesting that with high conformal radiation therapy and even with more sophisticated radiation techniques, such as high-dose-rate brachytherapy or image-guided intensity modulated radiation therapy, morbidity associated with shortening overall treatment time with higher doses per fraction remains low when compared with protracted conventional radiation therapy to the prostate only. In high-risk prostate cancer patients, there is accumulating evidence that either dose escalation to the prostate or hypofractionation may improve outcome. Nevertheless, selected patients who have a high risk of lymph node involvement may benefit from whole-pelvic radiation therapy (WPRT). Although combining WPRT with hypofractionated prostate radiation therapy is feasible, it remains investigational. By combining modern advances in radiation oncology (high-dose-rate prostate brachytherapy, intensity modulated radiation therapy with an improved image guidance for soft-tissue sparing), it is hypothesized that WPRT could take advantage of recent results from hypofractionation trials. Moreover, the results from hypofractionation trials raise questions as to whether hypofractionation to pelvic lymph nodes with a high risk of occult involvement might improve the outcomes in WPRT. Although investigational, this review discusses the challenging idea of WPRT in the context of hypofractionation for patients with high-risk prostate cancer.

  10. Cardiac dose reduction with deep inspiration breath hold for left-sided breast cancer radiotherapy patients with and without regional nodal irradiation.

    Science.gov (United States)

    Yeung, Rosanna; Conroy, Leigh; Long, Karen; Walrath, Daphne; Li, Haocheng; Smith, Wendy; Hudson, Alana; Phan, Tien

    2015-09-22

    Deep inspiration breath hold (DIBH) reduces heart and left anterior descending artery (LAD) dose during left-sided breast radiation therapy (RT); however there is limited information about which patients derive the most benefit from DIBH. The primary objective of this study was to determine which patients benefit the most from DIBH by comparing percent reduction in mean cardiac dose conferred by DIBH for patients treated with whole breast RT ± boost (WBRT) versus those receiving breast/chest wall plus regional nodal irradiation, including internal mammary chain (IMC) nodes (B/CWRT + RNI) using a modified wide tangent technique. A secondary objective was to determine if DIBH was required to meet a proposed heart dose constraint of Dmean irradiation.

  11. Offline multiple adaptive planning strategy for concurrent irradiation of the prostate and pelvic lymph nodes

    International Nuclear Information System (INIS)

    Qi, Peng; Xia, Ping; Pouliot, Jean; Roach, Mack

    2014-01-01

    Purpose: Concurrent irradiation of the prostate and pelvic lymph nodes (PLNs) can be challenging due to the independent motion of the two target volumes. To address this challenge, the authors have proposed a strategy referred to as Multiple Adaptive Planning (MAP). To minimize the number of MAP plans, the authors’ previous work only considered the prostate motion in one major direction. After analyzing the pattern of the prostate motion, the authors investigated a practical number of intensity-modulated radiotherapy (IMRT) plans needed to accommodate the prostate motion in two major directions simultaneously. Methods: Six patients, who received concurrent irradiation of the prostate and PLNs, were selected for this study. Nine MAP-IMRT plans were created for each patient with nine prostate contours that represented the prostate at nine locations with respect to the PLNs, including the original prostate contour and eight contours shifted either 5 mm in a single anterior-posterior (A-P), or superior-inferior (S-I) direction, or 5 mm in both A-P and S-I directions simultaneously. From archived megavoltage cone beam CT (MV-CBCT) and a dual imaging registration, 17 MV-CBCTs from 33 available MV-CBCT from these patients showed large prostate displacements (>3 mm in any direction) with respect to the pelvic bones. For each of these 17 fractions, one of nine MAP-IMRT plans was retrospectively selected and applied to the MV-CBCT for dose calculation. For comparison, a simulated isocenter-shifting plan and a reoptimized plan were also created for each of these 17 fractions. The doses to 95% (D95) of the prostate and PLNs, and the doses to 5% (D5) of the rectum and bladder were calculated and analyzed. Results: For the prostate, D95 > 97% of the prescription dose was observed in 16, 16, and 17 of 17 fractions for the MAP, isocenter-shifted, and reoptimized plans, respectively. For PLNs, D95 > 97% of the prescription doses was observed in 10, 3, and 17 of 17 fractions for

  12. A retrospective study of the effects of pelvic irradiation for carcinoma of the cervix on gastrointestinal function

    International Nuclear Information System (INIS)

    Yeoh, E.; Ahmad, A.; Horowitz, M.; Russo, A.; Muecke, T.; Chatterton, B.; Robb, T.

    1993-01-01

    The purpose of the study was to evaluate the prevalence of disordered gastrointestinal function following therapeutic irradiation. Gastrointestinal function was evaluated in 30 randomly selected patients who had received pelvic irradiation for treatment of carcinoma of the cervix between 1 and 6 years previously. Each patient underwent evaluations of (a) gastrointestinal symptoms (b) absorption of bile acid, vitamin B12, lactose and fat (c) gastrointestinal transit: gastric emptying, small intestinal transit and whole gut transit and (d) intestinal permeability. Results were compared with those obtained in 18 normal volunteers. Stool frequency was above the control range in five patients and had increased (p < 0.001) since radiotherapy treatment. Bile acid (p<0.001) vitamin B12(p<0.01) and lactose (p<0.01) absorption were less in the patients when compared with the control subjects. Bile acid adsorption was below the control range in 14 of the 30 patients. Dietary calcium intake was lower (p<0.05) in those patients with lactose malabsorption. Gastric emptying (p<0.01) and small intestinal transit (p<0.01) were more rapid in the patients. Both small intestinal (r=-0.39, p<0.05) and whole gut (r=-0.45) transit were inversely related to stool frequency. Either bowel frequency, bile acid adsorption, vitamin B12 absorption was outside the control range in 19 of the 30 patients. Abnormal gastrointestinal function is essentially an inevitable long-term sequel of pelvic irradiation. 41 refs., 4 figs., 3 tabs

  13. Involved-field radiotherapy (IFRT) versus elective nodal irradiation (ENI) in combination with concurrent chemotherapy for 239 esophageal cancers: a single institutional retrospective study

    International Nuclear Information System (INIS)

    Yamashita, Hideomi; Takenaka, Ryousuke; Omori, Mami; Imae, Toshikazu; Okuma, Kae; Ohtomo, Kuni; Nakagawa, Keiichi

    2015-01-01

    This retrospective study on early and locally advanced esophageal cancer was conducted to evaluate locoregional failure and its impact on survival by comparing involved field radiotherapy (IFRT) with elective nodal irradiation (ENI) in combination with concurrent chemotherapy. We assessed all patients with esophageal cancer of stages I-IV treated with definitive radiotherapy from June 2000 to March 2014. Between 2000 and 2011, ENI was used for all cases excluding high age cases. After Feb 2011, a prospective study about IFRT was started, and therefore IFRT was used since then for all cases. Concurrent chemotherapy regimen was nedaplatin (80 mg/m 2 at D1 and D29) and 5-fluorouracil (800 mg/m 2 at D1-4 and D29-32). Of the 239 consecutive patients assessed (120 ENI vs. 119 IFRT), 59 patients (24.7 %) had stage IV disease and all patients received at least one cycle of chemotherapy. The median follow-up time for survivors was 34.0 months. There were differences in 3-year local control (44.8 % vs. 55.5 %, p = 0.039), distant control (53.8 % vs. 69.9 %, p = 0.021) and overall survival (34.8 % vs. 51.6 %, p = 0.087) rates between ENI vs. IFRT, respectively. Patients treated with IFRT (8 %) demonstrated a significantly lower risk (p = 0.047) of high grade late toxicities than with ENI (16 %). IFRT did not increase the risk of initially uninvolved or isolated nodal failures (27.5 % in ENI and 13.4 % in IFRT). Nodal failure rates in clinically uninvolved nodal stations were not increased with IFRT when compared to ENI. IFRT also resulted in significantly decreased esophageal toxicity, suggesting that IFRT may allow for integration of concurrent systemic chemotherapy in a greater proportion of patients. Both tendencies of improved loco-regional progression-free survival and a significant increased overall survival rate favored the IFRT arm over the ENI arm in this study

  14. Involved-field radiotherapy (IFRT) versus elective nodal irradiation (ENI) in combination with concurrent chemotherapy for 239 esophageal cancers: a single institutional retrospective study.

    Science.gov (United States)

    Yamashita, Hideomi; Takenaka, Ryousuke; Omori, Mami; Imae, Toshikazu; Okuma, Kae; Ohtomo, Kuni; Nakagawa, Keiichi

    2015-08-14

    This retrospective study on early and locally advanced esophageal cancer was conducted to evaluate locoregional failure and its impact on survival by comparing involved field radiotherapy (IFRT) with elective nodal irradiation (ENI) in combination with concurrent chemotherapy. We assessed all patients with esophageal cancer of stages I-IV treated with definitive radiotherapy from June 2000 to March 2014. Between 2000 and 2011, ENI was used for all cases excluding high age cases. After Feb 2011, a prospective study about IFRT was started, and therefore IFRT was used since then for all cases. Concurrent chemotherapy regimen was nedaplatin (80 mg/m(2) at D1 and D29) and 5-fluorouracil (800 mg/m(2) at D1-4 and D29-32). Of the 239 consecutive patients assessed (120 ENI vs. 119 IFRT), 59 patients (24.7%) had stage IV disease and all patients received at least one cycle of chemotherapy. The median follow-up time for survivors was 34.0 months. There were differences in 3-year local control (44.8% vs. 55.5%, p = 0.039), distant control (53.8% vs. 69.9%, p = 0.021) and overall survival (34.8% vs. 51.6%, p = 0.087) rates between ENI vs. IFRT, respectively. Patients treated with IFRT (8 %) demonstrated a significantly lower risk (p = 0.047) of high grade late toxicities than with ENI (16%). IFRT did not increase the risk of initially uninvolved or isolated nodal failures (27.5% in ENI and 13.4% in IFRT). Nodal failure rates in clinically uninvolved nodal stations were not increased with IFRT when compared to ENI. IFRT also resulted in significantly decreased esophageal toxicity, suggesting that IFRT may allow for integration of concurrent systemic chemotherapy in a greater proportion of patients. Both tendencies of improved loco-regional progression-free survival and a significant increased overall survival rate favored the IFRT arm over the ENI arm in this study.

  15. Impact of Scattered Radiation onTestosterone Deficiency and MaleHypogonadism in Rectal Cancer Treatedwith External Beam Pelvic Irradiation

    Directory of Open Access Journals (Sweden)

    Halimeh Khatoon Ahmadi

    2010-07-01

    Full Text Available Background: We performed a prospective study to evaluate the effects of pelvic irradiation on FSH, LH and testosterone levels in male patients with rectal adenocarcinoma. Our aim was to compare the level of male sex hormones in peripheral blood serum before and after pelvic irradiation.Methods:The eligible participants were 40 men with rectal adenocarcinoma who underwent pelvic radiotherapy as part of their treatment for primary tumor, either beforeor after surgery. All patients received a 50-Gy radiation dose to the pelvis, 2 Gy perfraction, five days per week. Blood was sampled three times during the study: once before radiation, at the end of the radiation course and 4 to 6 weeks after radiotherapy.Results:Median age of the patients was 58 years (range 18-82. The mean testis dose of radiation per fraction in all 40 patients was 16.3 cGy with a standard deviation of 15.22 (range 5.5-64.8. Serum levels of FSH revealed a significant increase from 7.5 ± 1.7 IU/L(before treatment to 20.9 ± 17.8 IU/L[end of radiotherapy (P<0.001]and 24.1 ± 20.5 IU/L[4 to 6 weeks after radiotherapy (P<0.001]. Serum LH levelswere significantly elevated from 8.04 ± 1.2 IU/L before radiation to 11.6 ± 11.5 IU/Lat the end of radiotherapy (P<0.001 and 12.5 ± 9.9 IU/L4 to 6 weeks after the final course of radiotherapy (P<0.001. There was a decrease in serum testosterone from5.3±2.1 ng/mL before radiation to 4.2 ± 1.9 ng/mLat the end of radiotherapy (P=0.004and 4.5 ± 2 ng/mL4 to 6 weeks after radiotherapy (P=0.035. No significant correlation was seen between age and differences in sex hormones (LH, P=0.605; FSH, P=0.380;testosterone,P=0.161.Conclusion:There was a significant change in serum levels of male sex hormones after pelvic irradiation for rectal cancer (total dose, 50 Gy that indicates considerable testicular damage under these circumstances. Thus, it seems logical to use techniques that reduce the radiation dose to the testicles and to consider the

  16. 14C-lactose breath tests during pelvic radiotherapy: the effect of the amount of small bowel irradiated

    International Nuclear Information System (INIS)

    Weiss, R.G.; Stryker, J.A.

    1982-01-01

    Thirty patients who were undergoing pelvic radiotherapy had 14 C-lactose breath tests performed in the first and fifth weeks of treatment. In Group I (21 patients), a significant portion of the small intestine was irradiated, and in Group II (9 patients), only a small portion of the small intestine was irradiated. In Group I, the average reductions in the excretion of ingested 14 C between the first- and fifth-week tests were 41.5% at 1/2 hour postingestion (p less than 0.05), and 21.8% at 1 hour postingestion (p less than 0.05). In Group II, the percentage reductions were 11.8% and 3.7% at 1/2 and 1 hour, respectively (p greater than 0.05). The data suggest that lactose malabsorption is a factor in the etiology of the nausea, vomiting, and diarrhea experienced by patients who are undergoing pelvic radiotherapy, and that the amount of bowel included in the treatment volume significantly influences the degree of malabsorption

  17. A simple method of alignment for pelvic irradiation in obese patients

    International Nuclear Information System (INIS)

    Sweigart, Kenneth

    2002-01-01

    Administering radiation therapy to obese pelvic patients can pose a difficult challenge to even the veteran radiation therapist. Daily reproducibility can be achieved with the sacrifice of additional time and filming. We have developed a technique which has shown consistent reproducibility of the radiation treatments with a minimum of inconvenience to busy schedules

  18. Associations between volume changes and spatial dose metrics for the urinary bladder during local versus pelvic irradiation for prostate cancer.

    Science.gov (United States)

    Casares-Magaz, Oscar; Moiseenko, Vitali; Hopper, Austin; Pettersson, Niclas Johan; Thor, Maria; Knopp, Rick; Deasy, Joseph O; Muren, Ludvig Paul; Einck, John

    2017-06-01

    Inter-fractional variation in urinary bladder volumes during the course of radiotherapy (RT) for prostate cancer causes deviations between planned and delivered doses. This study compared planned versus daily cone-beam CT (CBCT)-based spatial bladder dose distributions, for prostate cancer patients receiving local prostate treatment (local treatment) versus prostate including pelvic lymph node irradiation (pelvic treatment). Twenty-seven patients (N = 15 local treatment; N = 12 pelvic treatment) were treated using daily image-guided RT (1.8 Gy@43-45 fx), adhering to a full bladder/empty rectum protocol. For each patient, 9-10 CBCTs were registered to the planning CT, using the clinically applied translations. The urinary bladder was manually segmented on each CBCT, 3 mm inner shells were generated, and semi and quadrant sectors were created using axial/coronal cuts. Planned and delivered DVH metrics were compared across patients and between the two groups of treatment (t-test, p bladder volume variations and the dose-volume histograms (DVH) of the bladder and its sectors were evaluated (Spearman's rank correlation coefficient, r s ). Bladder volumes varied considerably during RT (coefficient of variation: 16-58%). The population-averaged planned and delivered DVH metrics were not significantly different at any dose level. Larger treatment bladder volumes resulted in increased absolute volume of the posterior/inferior bladder sector receiving intermediate-high doses, in both groups. The superior bladder sector received less dose with larger bladder volumes for local treatments (r s  ± SD: -0.47 ± 0.32), but larger doses for pelvic treatments (r s  ± SD: 0.74 ± 0.24). Substantial bladder volume changes during the treatment course occurred even though patients were treated under a full bladder/daily image-guided protocol. Larger bladder volumes resulted in less bladder wall spared at the posterior-inferior sector, regardless the

  19. Radiotherapy alone for stage I-III low grade follicular lymphoma: long-term outcome and comparison of extended field and total nodal irradiation

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Alexandrow, Nikolaus; Flentje, Michael

    2012-01-01

    To analyze long-term results of radiotherapy alone for stage I-III low grade follicular lymphoma and to compare outcome after extended field irradiation (EFI) and total nodal irradiation (TNI). Between 1982 and 2007, 107 patients were treated with radiotherapy alone for low grade follicular lymphoma at Ann Arbor stage I (n = 50), II (n = 36) and III (n = 21); 48 and 59 patients were treated with EFI and TNI, respectively. The median total dose in the first treatment series of the diaphragmatic side with larger lymphoma burden was 38 Gy (25 Gy – 50 Gy) and after an interval of median 30 days, a total dose of 28 Gy (12.6 Gy – 45 Gy) was given in the second treatment series completing TNI. After a median follow-up of 14 years for living patients, 10-years and 15-years overall survival (OS) were 64% and 50%, respectively. Survival was not significantly different between stages I, II and III. TNI and EFI resulted in 15-years OS of 65% and 34% but patients treated with TNI were younger, had better performance status and higher stage of disease compared to patients treated with EFI. In multivariate analysis, only age at diagnosis (p < 0.001, relative risk [RR] 1.06) and Karnofsky performance status (p = 0.04, RR = 0.96) were significantly correlated with OS. Freedom from progression (FFP) was 58% and 56% after 10-years and 15-years, respectively. Recurrences outside the irradiated volume were significantly reduced after TNI compared to EFI; however, increased rates of in-field recurrences and extra-nodal out-of-field recurrence counterbalanced this effect resulting in no significant difference in FFP between TNI and EFI. In univariate analysis, FFP was significantly improved in stage I compared to stage II but no differences were observed between stages I/II and stage III. In multivariate analysis no patient or treatment parameter was correlated with FFP. Acute toxicity was significantly increased after TNI compared to EFI with a trend to increased late toxicity as

  20. Analysis of Incidental Radiation Dose to Uninvolved Mediastinal/Supraclavicular Lymph Nodes in Patients with Limited-Stage Small Cell Lung Cancer Treated Without Elective Nodal Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Irfan; DeMarco, Marylou; Stevens, Craig W. [Department of Radiation Oncology, H. Lee Moffitt Cancer Center, Tampa, FL (United States); Fulp, William J. [Biostatistics Core, H. Lee Moffitt Cancer Center, Tampa, FL (United States); Dilling, Thomas J., E-mail: Thomas.Dilling@moffitt.org [Department of Radiation Oncology, H. Lee Moffitt Cancer Center, Tampa, FL (United States)

    2011-01-01

    Classic teaching states that treatment of limited-stage small cell lung cancer (L-SCLC) requires large treatment fields covering the entire mediastinum. However, a trend in modern thoracic radiotherapy is toward more conformal fields, employing positron emission tomography/computed tomography (PET/CT) scans to determine the gross tumor volume (GTV). This analysis evaluates the dosimetric results when using selective nodal irradiation (SNI) to treat a patient with L-SCLC, quantitatively comparing the results to standard Intergroup treatment fields. Sixteen consecutive patients with L-SCLC and central mediastinal disease who also underwent pretherapy PET/CT scans were studied in this analysis. For each patient, we created SNI treatment volumes, based on the PET/CT-based criteria for malignancy. We also created 2 ENI plans, the first without heterogeneity corrections, as per the Intergroup 0096 study (ENI{sub off}) and the second with heterogeneity corrections while maintaining constant the number of MUs delivered between these latter 2 plans (ENI{sub on}). Nodal stations were contoured using published guidelines, then placed into 4 'bins' (treated nodes, 1 echelon away, >1 echelon away within the mediastinum, contralateral hilar/supraclavicular). These were aggregated across the patients in the study. Dose to these nodal bins and to tumor/normal structures were compared among these plans using pairwise t-tests. The ENI{sub on} plans demonstrated a statistically significant degradation in dose coverage compared with the ENI{sub off} plans. ENI and SNI both created a dose gradient to the lymph nodes across the mediastinum. Overall, the gradient was larger for the SNI plans, although the maximum dose to the '1 echelon away' nodes was not statistically different. Coverage of the GTV and planning target volume (PTV) were improved with SNI, while simultaneously reducing esophageal and spinal cord dose though at the expense of modestly reduced dose to

  1. Analysis of incidental radiation dose to uninvolved mediastinal/supraclavicular lymph nodes in patients with limited-stage small cell lung cancer treated without elective nodal irradiation.

    Science.gov (United States)

    Ahmed, Irfan; DeMarco, Marylou; Stevens, Craig W; Fulp, William J; Dilling, Thomas J

    2011-01-01

    Classic teaching states that treatment of limited-stage small cell lung cancer (L-SCLC) requires large treatment fields covering the entire mediastinum. However, a trend in modern thoracic radiotherapy is toward more conformal fields, employing positron emission tomography/computed tomography (PET/CT) scans to determine the gross tumor volume (GTV). This analysis evaluates the dosimetric results when using selective nodal irradiation (SNI) to treat a patient with L-SCLC, quantitatively comparing the results to standard Intergroup treatment fields. Sixteen consecutive patients with L-SCLC and central mediastinal disease who also underwent pretherapy PET/CT scans were studied in this analysis. For each patient, we created SNI treatment volumes, based on the PET/CT-based criteria for malignancy. We also created 2 ENI plans, the first without heterogeneity corrections, as per the Intergroup 0096 study (ENI(off)) and the second with heterogeneity corrections while maintaining constant the number of MUs delivered between these latter 2 plans (ENI(on)). Nodal stations were contoured using published guidelines, then placed into 4 "bins" (treated nodes, 1 echelon away, >1 echelon away within the mediastinum, contralateral hilar/supraclavicular). These were aggregated across the patients in the study. Dose to these nodal bins and to tumor/normal structures were compared among these plans using pairwise t-tests. The ENI(on) plans demonstrated a statistically significant degradation in dose coverage compared with the ENI(off) plans. ENI and SNI both created a dose gradient to the lymph nodes across the mediastinum. Overall, the gradient was larger for the SNI plans, although the maximum dose to the "1 echelon away" nodes was not statistically different. Coverage of the GTV and planning target volume (PTV) were improved with SNI, while simultaneously reducing esophageal and spinal cord dose though at the expense of modestly reduced dose to anatomically distant lymph nodes

  2. Postoperative low-pelvic irradiation for stage I-IIA cervical cancer patients with risk factors other than pelvic lymph node metastasis

    International Nuclear Information System (INIS)

    Hong, J.-H.; Tsai, C.-S.; Lai, C.-H.; Chang, T.-C.; Wang, C.-C.; Lee, Steve P.; Tseng, C.-J.; Hsueh, Swei

    2002-01-01

    Purpose: To retrospectively investigate whether postoperative low-pelvic radiotherapy (RT) is an appropriate treatment for node-negative, high-risk Stage I-IIA cervical cancer patients. Methods and Materials: A total of 228 Stage I-IIA cervical cancer patients treated by radical surgery and postoperative RT were included in this study. All patients had histopathologically negative pelvic node metastasis, but at least one of the following risk factors: parametrial involvement, positive or close resection margins, invasion depth two-thirds or greater cervical stromal thickness. Seventy-nine patients (35%) received 30-50 Gy (median 44) to whole pelvis and a boost dose to the low pelvis (whole-pelvic RT group); the other 149 patients (65%) received low-pelvic RT only (low-pelvic RT group). For both groups, the total external RT dose to the low pelvis ranged from 40 to 60 Gy (median 50). The potential factors associated with survival, small bowel (gastrointestinal) complications, and leg lymphedema were analyzed, and patients who had a relapse in the upper pelvis were identified. Results: The 5-year overall and disease-specific survival rate was 84% and 86%, respectively. After multivariate analysis, only bulky tumor (≥4 cm) and non-squamous cell carcinoma were significantly associated with survival. Parametrial involvement, lymph-vascular invasion, ≤50.4 Gy to the low pelvis, positive or close margins, and low-pelvic RT alone did not significantly affect survival. Grade I-V small bowel complications occurred in 33 patients (15%). Whole pelvic RT and >50.4 Gy to the low pelvis, but not old age and treatment technique (AP-PA vs. box), were significantly associated with gastrointestinal complications. Three patients (2%) in the low-pelvic RT group and 6 patients (8%) in the whole-pelvic RT group were found to have Grade III or higher small bowel complications (p=0.023). Thirty-one percent of patients developed lymphedema of the leg. A dose to the low pelvis >50.4 Gy

  3. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC: A direct comparison of PET-based treatment planning.

    Science.gov (United States)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Rübe, Christian

    2016-02-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels.

  4. Effect of pelvic irradiation of lactose absorption. [. gamma. rays or x rays were used in gynecologic malignancy therapy

    Energy Technology Data Exchange (ETDEWEB)

    Stryker, J.A.; Mortel, R.; Hepner, G.W.

    1978-01-01

    Twenty-four patients undergoing pelvic irradiation for gynecologic malignancies had /sup 14/C-lactose breath tests performed in the first and fifth weeks of their treatment. The /sup 14/C-lactose breath test was performed by administering 2 ..mu..Ci of /sup 14/C-lactose by mouth along with 50 g of lactose. Breath samples were collected in ethanolic hyamine 1, 2, and 3 hr later; the radioactivity of the trapped /sup 14/CO/sub 2/ was determined by liquid scintillation spectroscopy. In the first week of treatment the percentage of administered /sup 14/C excreted as /sup 14/CO/sub 2/ at 1, 2, and 3 hr was 1.7 +- 0.8% (mean +- SD), 4.5 +- 1.6%, and 5.8 +- 1.4%, respectively. In the fifth week of treatment the 1-hr, 2-hr, and 3-hr values were 1.2 +- 0.9%, 3.6 +- 2.0%, and 4.7 +- 1.9%, respectively. The difference between the first week and fifth week test results at 1, 2, and 3 hr was statistically significant (t = 2.64, p < 0.02), (t = 2.24, p < 0.05), (t = 2.95, p < 0.01). There was a negative correlation between the 1-hr /sup 14/C-lactose breath test results in the fifth week and the stool frequency at that time (r = -0.44, p < 0.05). Seven of 12 patients whose 1 hr /sup 14/C-lactose breath test results in the fifth week were below normal (<1.2%) had nausea at that time. The data suggest that in some patients, lactose malabsorption as a result of the effect of radiation on small intestinal function may be etiologically related to the symptoms of nausea and diarrhea which occur commonly in patients who are undergoing pelvic irradiation. In addition, the results suggest that lactose-containing foods should be restricted in some patients who are undergoing pelvic irradiation to prevent symptoms resulting from radiation-induced lactose intolerance.

  5. Irradiation of the prostate and pelvic lymph nodes with an adaptive algorithm

    International Nuclear Information System (INIS)

    Hwang, A. B.; Chen, J.; Nguyen, T. B.; Gottschalk, A. G.; Roach, M. R. III; Pouliot, J.

    2012-01-01

    Purpose: The simultaneous treatment of pelvic lymph nodes and the prostate in radiotherapy for prostate cancer is complicated by the independent motion of these two target volumes. In this work, the authors study a method to adapt intensity modulated radiation therapy (IMRT) treatment plans so as to compensate for this motion by adaptively morphing the multileaf collimator apertures and adjusting the segment weights. Methods: The study used CT images, tumor volumes, and normal tissue contours from patients treated in our institution. An IMRT treatment plan was then created using direct aperture optimization to deliver 45 Gy to the pelvic lymph nodes and 50 Gy to the prostate and seminal vesicles. The prostate target volume was then shifted in either the anterior-posterior direction or in the superior-inferior direction. The treatment plan was adapted by adjusting the aperture shapes with or without re-optimizing the segment weighting. The dose to the target volumes was then determined for the adapted plan. Results: Without compensation for prostate motion, 1 cm shifts of the prostate resulted in an average decrease of 14% in D-95%. If the isocenter is simply shifted to match the prostate motion, the prostate receives the correct dose but the pelvic lymph nodes are underdosed by 14% ± 6%. The use of adaptive morphing (with or without segment weight optimization) reduces the average change in D-95% to less than 5% for both the pelvic lymph nodes and the prostate. Conclusions: Adaptive morphing with and without segment weight optimization can be used to compensate for the independent motion of the prostate and lymph nodes when combined with daily imaging or other methods to track the prostate motion. This method allows the delivery of the correct dose to both the prostate and lymph nodes with only small changes to the dose delivered to the target volumes.

  6. Intensity-modulated proton therapy for elective nodal irradiation and involved-field radiation in the definitive treatment of locally advanced non-small-cell lung cancer: a dosimetric study.

    Science.gov (United States)

    Kesarwala, Aparna H; Ko, Christine J; Ning, Holly; Xanthopoulos, Eric; Haglund, Karl E; O'Meara, William P; Simone, Charles B; Rengan, Ramesh

    2015-05-01

    Photon involved-field (IF) radiation therapy (IFRT), the standard for locally advanced (LA) non-small cell lung cancer (NSCLC), results in favorable outcomes without increased isolated nodal failures, perhaps from scattered dose to elective nodal stations. Because of the high conformality of intensity-modulated proton therapy (IMPT), proton IFRT could increase nodal failures. We investigated the feasibility of IMPT for elective nodal irradiation (ENI) in LA-NSCLC. IMPT IFRT plans were generated to the same total dose of 66.6-72 Gy received by 20 LA-NSCLC patients treated with photon IFRT. IMPT ENI plans were generated to 46 cobalt Gray equivalent (CGE) to elective nodal planning treatment volumes (PTV) plus 24 CGE to IF-PTVs. Proton IFRT and ENI improved the IF-PTV percentage of volume receiving 95% of the prescribed dose (D95) by 4% (P ENI. The mean esophagus dose decreased 16% with IFRT and 12% with ENI; heart V25 decreased 63% with both (all P ENI. Potential decreased toxicity indicates that IMPT could allow ENI while maintaining a favorable therapeutic ratio compared with photon IFRT. Published by Elsevier Inc.

  7. Intensity-Modulated Proton Therapy for Elective Nodal Irradiation and Involved-Field Radiation in the Definitive Treatment of Locally Advanced Non-Small Cell Lung Cancer: A Dosimetric Study

    Science.gov (United States)

    Kesarwala, Aparna H.; Ko, Christine J.; Ning, Holly; Xanthopoulos, Eric; Haglund, Karl E.; O’Meara, William P.; Simone, Charles B.; Rengan, Ramesh

    2015-01-01

    Background Photon involved-field radiation therapy (IFRT), the standard for locally advanced non-small cell lung cancer (LA-NSCLC), results in favorable outcomes without increased isolated nodal failures, perhaps from scattered dose to elective nodal stations. Given the high conformality of intensity-modulated proton therapy (IMPT), proton IFRT could increase nodal failures. We investigated the feasibility of IMPT for elective nodal irradiation (ENI) in LA-NSCLC. Materials and Methods IMPT IFRT plans were generated to the same total dose of 66.6–72 Gy received by 20 LA-NSCLC patients treated with photon IFRT. IMPT ENI plans were generated to 46 CGE to elective nodal (EN) planning treatment volumes (PTV) plus 24 CGE to involved field (IF)-PTVs. Results Proton IFRT and ENI both improved D95 involved field (IF)-PTV coverage by 4% (pENI. Mean esophagus dose decreased 16% with IFRT and 12% with ENI; heart V25 decreased 63% with both (all pENI. Potential decreased toxicity indicates IMPT could allow ENI while maintaining a favorable therapeutic ratio compared to photon IFRT. PMID:25604729

  8. A method for evaluation of proton plan robustness towards inter-fractional motion applied to pelvic lymph node irradiation

    DEFF Research Database (Denmark)

    Andersen, Andreas G; Casares-Magaz, Oscar; Muren, Ludvig P

    2015-01-01

    of the pelvic lymph nodes (LNs) from different beam angles. Patient- versus population-specific patterns in dose deterioration were explored. MATERIAL AND METHODS: Patient data sets consisting of a planning computed tomography (pCT) as well as multiple repeat CT (rCT) scans for three patients were used......BACKGROUND: The benefit of proton therapy may be jeopardized by dose deterioration caused by water equivalent path length (WEPL) variations. In this study we introduced a method to evaluate robustness of proton therapy with respect to inter-fractional motion and applied it to irradiation...... in deterioration patterns were found for the investigated patients, with beam angles delivering less dose to rectum, bladder and overall normal tissue identified around 40° and around 150°-160° for the left LNs, and corresponding angles for the right LNs. These angles were also associated with low values of WEPL...

  9. Cardiac dose reduction with deep inspiration breath hold for left-sided breast cancer radiotherapy patients with and without regional nodal irradiation

    International Nuclear Information System (INIS)

    Yeung, Rosanna; Conroy, Leigh; Long, Karen; Walrath, Daphne; Li, Haocheng; Smith, Wendy; Hudson, Alana; Phan, Tien

    2015-01-01

    Deep inspiration breath hold (DIBH) reduces heart and left anterior descending artery (LAD) dose during left-sided breast radiation therapy (RT); however there is limited information about which patients derive the most benefit from DIBH. The primary objective of this study was to determine which patients benefit the most from DIBH by comparing percent reduction in mean cardiac dose conferred by DIBH for patients treated with whole breast RT ± boost (WBRT) versus those receiving breast/chest wall plus regional nodal irradiation, including internal mammary chain (IMC) nodes (B/CWRT + RNI) using a modified wide tangent technique. A secondary objective was to determine if DIBH was required to meet a proposed heart dose constraint of D mean < 4 Gy in these two cohorts. Twenty consecutive patients underwent CT simulation both free breathing (FB) and DIBH. Patients were grouped into two cohorts: WBRT (n = 11) and B/CWRT + RNI (n = 9). 3D-conformal plans were developed and FB was compared to DIBH for each cohort using Wilcoxon signed-rank tests for continuous variables and McNemar’s test for discrete variables. The percent relative reduction conferred by DIBH in mean heart and LAD dose, as well as lung V 20 were compared between the two cohorts using Wilcox rank-sum testing. The significance level was set at 0.05 with Bonferroni correction for multiple testing. All patients had comparable target coverage on DIBH and FB. DIBH statistically significantly reduced mean heart and LAD dose for both cohorts. Percent reduction in mean heart and LAD dose with DIBH was significantly larger in the B/CWRT + RNI cohort compared to WBRT group (relative reduction in mean heart and LAD dose: 55.9 % and 72.1 % versus 29.2 % and 43.5 %, p < 0.02). All patients in the WBRT group and five patients (56 %) in the B/CWBRT + RNI group met heart D mean <4 Gy with FB. All patients met this constraint with DIBH. All patients receiving WBRT met D mean Heart < 4 Gy on FB, while only slightly over

  10. Bone marrow transplantation for girls with aplastic anemia utilizing modified field of total lymphoid irradiation and cyclophosphamide; With emphasis on the field of pelvic cavity

    Energy Technology Data Exchange (ETDEWEB)

    Hanada, Ryoji; Kawakami, Tetsuo; Akuta, Naoko; Moriwaki, Kohichi; Kato, Shizue; Inaba, Toshiya; Hayashi, Yasuhide; Yamamoto, Keiko (Saitama Children' s Medical Center, Saitama (Japan))

    1990-12-01

    A preparative regimen for allogeneic bone marrow transplantation, consisting of total lymphoid irradiation (TLI) with 750 cGy and cyclophosphamide (CY), was used in five girls with aplastic anemia. All patients received bone marrow from HLA matched/mixed lymphocyte culture negative siblings. In our regimen the 'inverted Y' field to irradiate the pelvic nodes was modified, which did not include the whole pelvic cavity in an attempt to protect the ovaries from irradiation. Although some of the pelvic nodes was supported not to be irradiated in order to protect the ovaries, engraftment occurred in all five patients including four who had been transfused prior to transplantation. All five are alive from 47 days to 1378 days (median 285 days) after transplantation without tranplantation-associated complications. The calculated dose to the ovaries was sixteen percent of the entire dose of the regimen. Both of the two evaluable patients that had received tranplantation just before or during the puberty are developing normal sex maturity including menstruation. This study suggests that our preparative regimen is effective not only for engraftment of the donor marrow but also for protecting the ovaries from irradiation. (author).

  11. Results of a Phase 2 Study Examining the Effects of Omitting Elective Neck Irradiation to Nodal Levels IV and V{sub b} in Patients With N{sub 0-1} Nasopharyngeal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jian-zhou [Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong (China); Le, Quynh-Thu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Han, Fei; Lu, Li-Xia; Huang, Shao-Min; Lin, Cheng-Guang; Deng, Xiao-Wu; Cui, Nian-Ji [State Key Laboratory of Oncology in South China, Department of Radiation Oncology, Cancer Center of Sun Yat-Sen University, Guangzhou, Guangdong (China); Zhao, Chong, E-mail: gzzhaochong@hotmail.com [State Key Laboratory of Oncology in South China, Department of Radiation Oncology, Cancer Center of Sun Yat-Sen University, Guangzhou, Guangdong (China)

    2013-03-15

    Purpose: To evaluate the patterns of nodal failure and toxicity in clinically negative necks of N{sub 0-1} nasopharyngeal carcinoma (NPC) patients who were treated with intensity modulated radiation therapy (IMRT) but did not receive elective neck irradiation (ENI) to level IV and V{sub b} nodes. Methods and Materials: We conducted a phase 2 prospective study in N{sub 0-1} NPC patients treated with IMRT. ENI included the retropharyngeal nodes and levels II to V{sub a} but omitted levels IV and V{sub b} in clinically negative necks. Patterns of nodal failure, regional control (RC), and late toxicity were evaluated. Results: Between 2001 and 2008, a total of 212 patients (128 N{sub 0} and 84 N{sub 1}) were enrolled in the study. Seven patients (4 in-field and 3 out-of-field) developed nodal failure. One patient (0.5%) developed nodal failure at level V{sub b}, but no patients developed nodal failure at level IV. The 5-year RC rates of the entire group, N{sub 0} patients and N{sub 1} patients were 95.6%, 98.2%, and 91.3%, respectively. Fifteen patients (7.1%) developed distant metastases. The 5-year distant failure-free survival (DFFS) and overall survival (OS) rates were 91.4% and 89.8%, respectively. The rates of grade 2 or greater skin dystrophy, subcutaneous fibrosis and xerostomia were 6.2%, 16.6%, and 17.9%, respectively. Conclusions: The rate of out-of-field nodal failure when omitting ENI to levels IV and V{sub b} in clinically negative necks of patients with N{sub 0-1} NPC was extremely low; therefore, a further phase 3 study is warranted.

  12. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    International Nuclear Information System (INIS)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian

    2016-01-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [de

  13. Randomised phase III trial of concurrent chemoradiotherapy with extended nodal irradiation and erlotinib in patients with inoperable oesophageal squamous cell cancer.

    Science.gov (United States)

    Wu, Shi-Xiu; Wang, Lv-Hua; Luo, Hong-Lei; Xie, Cong-Ying; Zhang, Xue-Bang; Hu, Wei; Zheng, An-Ping; Li, Duo-Jie; Zhang, Hong-Yan; Xie, Cong-Hua; Lian, Xi-Long; Du, De-Xi; Chen, Ming; Bian, Xiu-Hua; Tan, Bang-Xian; Jiang, Hao; Zhang, Hong-Bo; Wang, Jian-Hua; Jing, Zhao; Xia, Bing; Zhang, Ni; Zhang, Ping; Li, Wen-Feng; Zhao, Fu-Jun; Tian, Zhi-Feng; Liu, Hui; Huang, Ke-Wei; Hu, Jin; Xie, Rui-Fei; Du, Lin; Li, Gang

    2018-04-01

    This randomised phase III study was conducted to investigate the efficacy of extended nodal irradiation (ENI) and/or erlotinib in inoperable oesophageal squamous cell cancer (ESCC). Patients with histologically confirmed locally advanced ESCC or medically inoperable disease were randomly assigned (ratio 1:1:1:1) to one of four treatment groups: group A, radiotherapy adoption of ENI with two cycles of concurrent TP chemotherapy (paclitaxel 135 mg/m 2  day 1 and cisplatin 20 mg/m 2 days 1-3, every 4 weeks) plus erlotinib (150 mg per day during chemoradiotherapy); group B, radiotherapy adoption of ENI with two cycles of concurrent TP; group C, radiotherapy adoption of conventional field irradiation (CFI) with two cycles of concurrent TP plus erlotinib; group D, radiotherapy adoption of CFI with two cycles of concurrent TP. A total of 352 patients (88 assigned to each treatment group) were enrolled. The 2-year overall survival rates of group A, B, C and D were 57.8%, 49.9%, 44.9% and 38.7%, respectively (P = 0.015). Group A significantly improved 2-year overall survival compared with group D. The ENI significantly improved overall survival in patients with inoperable ESCC (P = 0.014). The addition of erlotinib significantly decreased loco-regional recurrence (P = 0.042). Aside from rash and radiation oesophagitis, the incidence of grade 3 or greater toxicities did not differ among 4 groups. Chemoradiotherapy with ENI and erlotinib might represent a substantial improvement on the standard of care for inoperable ESCC. ENI alone should be adopted in concurrent chemoradiotherapy for ESCC patients. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Is elective nodal irradiation beneficial in patients with pathologically negative lymph nodes after neoadjuvant chemotherapy and breast-conserving surgery for clinical stage II–III breast cancer? A multicentre retrospective study (KROG 12-05)

    Science.gov (United States)

    Noh, J M; Park, W; Suh, C-O; Keum, K C; Kim, Y B; Shin, K H; Kim, K; Chie, E K; Ha, S W; Kim, S S; Ahn, S D; Shin, H S; Kim, J H; Lee, H-S; Lee, N K; Huh, S J; Choi, D H

    2014-01-01

    Background: To evaluate the effects of elective nodal irradiation (ENI) in clinical stage II–III breast cancer patients with pathologically negative lymph nodes (LNs) (ypN0) after neoadjuvant chemotherapy (NAC) followed by breast-conserving surgery (BCS) and radiotherapy (RT). Methods: We retrospectively analysed 260 patients with ypN0 who received NAC followed by BCS and RT. Elective nodal irradiation was delivered to 136 (52.3%) patients. The effects of ENI on survival outcomes were evaluated. Results: After a median follow-up period of 66.2 months (range, 15.6–127.4 months), 26 patients (10.0%) developed disease recurrence. The 5-year locoregional recurrence-free survival and disease-free survival (DFS) for all patients were 95.5% and 90.5%, respectively. Pathologic T classification (0−is vs 1 vs 2–4) and the number of LNs sampled (ENI. Elective nodal irradiation also did not affect survival outcomes in any of the subgroups according to pathologic T classification or the number of LNs sampled. Conclusions: ENI may be omitted in patients with ypN0 breast cancer after NAC and BCS. But until the results of the randomised trials are available, patients should be put on these trials. PMID:24481403

  15. Is elective nodal irradiation beneficial in patients with pathologically negative lymph nodes after neoadjuvant chemotherapy and breast-conserving surgery for clinical stage II-III breast cancer? A multicentre retrospective study (KROG 12-05).

    Science.gov (United States)

    Noh, J M; Park, W; Suh, C-O; Keum, K C; Kim, Y B; Shin, K H; Kim, K; Chie, E K; Ha, S W; Kim, S S; Ahn, S D; Shin, H S; Kim, J H; Lee, H-S; Lee, N K; Huh, S J; Choi, D H

    2014-03-18

    To evaluate the effects of elective nodal irradiation (ENI) in clinical stage II-III breast cancer patients with pathologically negative lymph nodes (LNs) (ypN0) after neoadjuvant chemotherapy (NAC) followed by breast-conserving surgery (BCS) and radiotherapy (RT). We retrospectively analysed 260 patients with ypN0 who received NAC followed by BCS and RT. Elective nodal irradiation was delivered to 136 (52.3%) patients. The effects of ENI on survival outcomes were evaluated. After a median follow-up period of 66.2 months (range, 15.6-127.4 months), 26 patients (10.0%) developed disease recurrence. The 5-year locoregional recurrence-free survival and disease-free survival (DFS) for all patients were 95.5% and 90.5%, respectively. Pathologic T classification (0-is vs 1 vs 2-4) and the number of LNs sampled (ENI. Elective nodal irradiation also did not affect survival outcomes in any of the subgroups according to pathologic T classification or the number of LNs sampled. ENI may be omitted in patients with ypN0 breast cancer after NAC and BCS. But until the results of the randomised trials are available, patients should be put on these trials.

  16. Facilitation of nodal metastasis from a non-immunogenic murine carcinoma by previous whole-body irradiation of tumour recipients

    International Nuclear Information System (INIS)

    Hewitt, H.B.; Blake, E.R.

    1977-01-01

    Of 193 CBA mice kept under prolonged observation after excision of small intradermal transplants of a non-immunogenic tumour (CBA Carcinoma NT), 27 (14%) presented with local recurrence, 19 (10%) with regional lymphnodal metastasis (RNM) and 72 (37%), with pulmonary metastasis +- other systemic metastases. When mice were exposed to sublethal whole-body irradiation (WBI) before tumour transplantation, the incidence of RNM rose to approximately 80% and the latent period was reduced from approximately 60 days to approximately 40 days after tumour transplantation. This enhancement of RNM by WBI was undiminished when the interval between WBI and tumour transplantation was increased from 1 to 90 days. An explanation for this effect in terms of immunosuppression by the WBI is unlikely for the following reasons: the tumour was non-immunogenic by standard quantitative tests; the effect persisted long after the expected time for recovery of immune reactivity; and i.v. injection of normal marrow and lymphoid cells after WBI failed to reduce the effect. That the effect was systemic was proved by failure of local pre-irradiation of the tumour bed or regional node to enhance RNM. The effect was not observed when WBI was given 4 days after excision of tumours. These and other experiments failed to indicate the mechanism of the effect of WBI, but its long persistence suggests that it may relate to stored lethal radiation damage in migrating cells of slow turnover tissues. (author)

  17. Regional Nodal Irradiation After Breast Conserving Surgery for Early HER2-Positive Breast Cancer: Results of a Subanalysis From the ALTTO Trial.

    Science.gov (United States)

    Gingras, Isabelle; Holmes, Eileen; De Azambuja, Evandro; Nguyen, David H A; Izquierdo, Miguel; Anne Zujewski, Jo; Inbar, Moshe; Naume, Bjorn; Tomasello, Gianluca; Gralow, Julie R; Wolff, Antonio C; Harris, Lyndsay; Gnant, Michael; Moreno-Aspitia, Alvaro; Piccart, Martine J; Azim, Hatem A

    2017-08-01

    Two randomized trials recently demonstrated that regional nodal irradiation (RNI) could reduce the risk of recurrence in early breast cancer; however, these trials were conducted in the pretrastuzumab era. Whether these results are applicable to human epidermal growth factor receptor 2 (HER2)-positive breast cancer patients treated with anti-HER2-targeted therapy is unknown. This retrospective analysis was performed on patients with node-positive breast cancer who were enrolled in the Adjuvant Lapatinib and/or Trastuzumab Treatment Optimization phase III adjuvant trial and subjected to BCS. The primary objective of the present study was to examine the effect of RNI on disease-free survival (DFS). A multivariable cox regression analysis adjusted for number of positive lymph nodes, tumor size, grade, age, hormone receptors status, presence of macrometastatis, treatment arm, and chemotherapy timing was carried out to investigate the relationship between RNI and DFS. One thousand six hundred sixty-four HER2-positive breast cancer patients were included, of whom 878 (52.8%) had received RNI to the axillary, supraclavicular, and/or internal mammary lymph nodes. Patients in the RNI group had higher nodal burden and more frequently had tumors larger than 2 cm. At a median follow-up of 4.5 years, DFS was 84.3% in the RNI group and 88.3% in the non-RNI group. No differences in regional recurrence (0.9 % vs 0.6 %) or in overall survival (93.6% vs 95.3%) were observed between the two groups. After adjustment in multivariable analysis, there was no statistically significant association between RNI and DFS (hazard ratio = 0.96, 95% confidence interval = 0.71 to 1.29). Our analysis did not demonstrate a DFS benefit of RNI in HER2-positive, node-positive patients treated with adjuvant HER2-targeted therapy. The benefit of RNI in HER2-positive breast cancer needs further testing within randomized clinical trials. © The Author 2017. Published by Oxford University Press. All

  18. Design of compensators for patients with hip prostheses undergoing pelvic irradiation

    International Nuclear Information System (INIS)

    Alecu, R.; Feldmeier, J.; He, T.; Alecu, M.; Court, W.; Orton, C.G.

    1995-01-01

    The perturbations in the dose distribution caused by a hip prosthesis when treating pelvic cancers have been evaluated and found to be significant by several investigators. Treatment techniques not including the prosthesis are often not the best choice. The goal of this study is to investigate the feasibility and usefulness of design of compensators in routine clinical practice for any kind of hip prosthesis. The calculation procedures and the algorithms developed by the authors for generating the compensators are described for two systems: one based on a locally developed 3-D computerized treatment planning system and an other one practicable in any institution which does not have access to a 3D treatment planning system or CT. The methodology to create the compensators for a patient is explained. To evaluate the constructed compensators in phantom and in vivo measurements were performed. The results are presented along with a comparison between the two methods

  19. Feasibility of Elective Nodal Irradiation (ENI) and Involved Field Irradiation (IFI) in Radiotherapy for the Elderly Patients (Aged ≥ 70 Years) with Esophageal Squamous Cell Cancer: A Retrospective Analysis from a Single Institute.

    Science.gov (United States)

    Jing, Wang; Zhu, Hui; Guo, Hongbo; Zhang, Yan; Shi, Fang; Han, Anqin; Li, Minghuan; Kong, Li; Yu, Jinming

    2015-01-01

    We conducted a retrospective analysis to assess the feasibility of involved field irradiation (IFI) in elderly patients with esophageal squamous cell cancer (ESCC). We performed a retrospective review of the records of elderly patients (≥ 70 years) with unresectable ESCC and no distant metastases who received treatment with radiotherapy between January 2009 and March 2013. According to the irradiation volume, patients were allocated into either the elective nodal irradiation (ENI) group or the IFI group. Overall survival (OS), progression-free survival (PFS) and treatment-related toxicities were compared between the two groups. A total of 137 patients were enrolled. Fifty-four patients (39.4%) were allocated to the ENI group and 83 patients (60.6%) to the IFI group, the median doses in the two groups were 60 Gy and 59.4 Gy, respectively. For the entire group, the median survival time (MST) and PFS were 16 months and 12 months, respectively. The median PFS and 3-year PFS rate in the ENI group were 13 months and 20.6%, compared to 11 months and 21.0% in the IFI groups (p = 0.61). The MST and 3-year OS rate in the ENI and IFI groups were 17 months and 26.4% and 15.5 months and 21.7%, respectively (p = 0.25). The rate of grade ≥ 3 acute irradiation esophagitis in the ENI group was significantly higher than that in the IFI group (18.5% vs. 6.0%; p = 0.027). Other grade ≥ 3 treatment-related toxicities did not significantly differ between the two groups. IFI resulted in decreased irradiation toxicities without sacrificing OS in elderly patients with ESCC.

  20. External Pelvic and Vaginal Irradiation Versus Vaginal Irradiation Alone as Postoperative Therapy in Medium-Risk Endometrial Carcinoma—A Prospective Randomized Study

    International Nuclear Information System (INIS)

    Sorbe, Bengt; Horvath, György; Andersson, Håkan; Boman, Karin; Lundgren, Caroline; Pettersson, Birgitta

    2012-01-01

    Purpose: To evaluate the value of adjuvant external beam pelvic radiotherapy as adjunct to vaginal brachytherapy (VBT) in medium-risk endometrial carcinoma, with regard to locoregional tumor control, recurrences, survival, and toxicity. Methods and Materials: Consecutive series of 527 evaluable patients were included in this randomized trial. Median follow-up for patients alive was 62 months. The primary study endpoints were locoregional recurrences and overall survival. Secondary endpoints were recurrence-free survival, recurrence-free interval, cancer-specific survival, and toxicity. Results: Five-year locoregional relapse rates were 1.5% after external beam radiotherapy (EBRT) plus VBT and 5% after vaginal irradiation alone (p = 0.013), and 5-year overall survival rates were 89% and 90%, respectively (p = 0.548). Endometrial cancer-related death rates were 3.8% after EBRT plus VBT and 6.8% after VBT (p = 0.118). Pelvic recurrences (exclusively vaginal recurrence) were reduced by 93% by the addition of EBRT to VBT. Deep myometrial infiltration was a significant prognostic factor in this medium-risk group of endometrioid carcinomas but not International Federation of Gynecology and Obstetrics grade or DNA ploidy. Combined radiotherapy was well tolerated, with serious (Grade 3) late side effects of less than 2%. However, there was a significant difference in favor of VBT alone. Conclusions: Despite a significant locoregional control benefit with combined radiotherapy, no survival improvement was recorded, but increased late toxicity was noted in the intestine, bladder, and vagina. Combined RT should probably be reserved for high-risk cases with two or more high-risk factors. VBT alone should be the adjuvant treatment option for purely medium-risk cases.

  1. Dosimetric evaluation of the feasibility of stereotactic body radiotherapy for primary lung cancer with lobe-specific selective elective nodal irradiation.

    Science.gov (United States)

    Komatsu, Tetsuya; Kunieda, Etsuo; Kitahara, Tadashi; Akiba, Takeshi; Nagao, Ryuta; Fukuzawa, Tsuyoshi

    2016-01-01

    More than 10% of all patients treated with stereotactic body radiotherapy (SBRT) for primary lung cancer develop regional lymph node recurrence. We evaluated the dosimetric feasibility of SBRT with lobe-specific selective elective nodal irradiation (ENI) on dose-volume histograms. A total of 21 patients were treated with SBRT for Stage I primary lung cancer between January 2010 and June 2012 at our institution. The extents of lobe-specific selective ENI fields were determined with reference to prior surgical reports. The ENI fields included lymph node stations (LNS) 3 + 4 + 11 for the right upper lobe tumors, LNS 7 + 11 for the right middle or lower lobe tumors, LNS 5 + 11 for the left upper lobe tumors, and LNS 7 + 11 for the left lower lobe tumors. A composite plan was generated by combining the ENI plan and the SBRT plan and recalculating for biologically equivalent doses of 2 Gy per fraction, using a linear quadratic model. The V20 of the lung, D(1cm3) of the spinal cord, D(1cm3) and D(10cm3) of the esophagus and D(10cm3) of the tracheobronchial wall were evaluated. Of the 21 patients, nine patients (43%) could not fulfill the dose constraints. In all these patients, the distance between the planning target volume (PTV) of ENI (PTVeni) and the PTV of SBRT (PTVsrt) was ≤2.0 cm. Of the three patients who developed regional metastasis, two patients had isolated lymph node failure, and the lymph node metastasis was included within the ENI field. When the distance between the PTVeni and PTVsrt is >2.0 cm, SBRT with selective ENI may therefore dosimetrically feasible. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  2. Changes in spinal and femoral bone mineral density due to pelvic irradiation following oophorectomy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jui-Tung; Hirai, Yasuo; Seimiya, Yumiko; Hasumi, Katsuhiko; Masubuchi, Kazumasa (Japanese Foundation for Cancer Research, Tokyo (Japan). Hospital); Shiraki, Masataka

    1991-10-01

    Since radiation therapy has been known to be a cause of bone atrophy (radiation osteopathy), it could be important whether postoperative radiotherapy in patients who have undergone oophorectomy further promotes bone mineral loss or not. Nineteen patients with stage Ib to IIb cervical cancer were studied. Eleven of the 19 patients received only surgical treatment and 8 received postoperative radiotherapy (50 Gy to the pelvis and 40 Gy to the lumber spine), because of the presence of advanced lesions or positive lymphnodes. A significant increase in FSH and decrease in E{sub 2} (p<0.01) compared to before treatment were observed in both groups. A significant increase in serum alkaline phosphatase activities (p<0.01), urine-calcium/creatinine ratio (p<0.05) and urine-hydroxyproline/creatinine ratio (p<0.01), which indicated high bone turnover, compared to before treatment in both groups also appeared. Although these chemical parameters in both groups changed coincidentally, the decline in spinal bone mineral density in the irradiated group was delayed at 12 months after the treatment. On the other hand, there was no difference in the changes in femoral bone mineral density in the two groups. These results suggest that radiotherapy might inhibit the bone mineral loss at the irradiated bone site even when there was an estrogen lack. (author).

  3. Changes in spinal and femoral bone mineral density due to pelvic irradiation following oophorectomy

    International Nuclear Information System (INIS)

    Chen, Jui-Tung; Hirai, Yasuo; Seimiya, Yumiko; Hasumi, Katsuhiko; Masubuchi, Kazumasa; Shiraki, Masataka.

    1991-01-01

    Since radiation therapy has been known to be a cause of bone atrophy (radiation osteopathy), it could be important whether postoperative radiotherapy in patients who have undergone oophorectomy further promotes bone mineral loss or not. Nineteen patients with stage Ib to IIb cervical cancer were studied. Eleven of the 19 patients received only surgical treatment and 8 received postoperative radiotherapy (50 Gy to the pelvis and 40 Gy to the lumber spine), because of the presence of advanced lesions or positive lymphnodes. A significant increase in FSH and decrease in E 2 (p<0.01) compared to before treatment were observed in both groups. A significant increase in serum alkaline phosphatase activities (p<0.01), urine-calcium/creatinine ratio (p<0.05) and urine-hydroxyproline/creatinine ratio (p<0.01), which indicated high bone turnover, compared to before treatment in both groups also appeared. Although these chemical parameters in both groups changed coincidentally, the decline in spinal bone mineral density in the irradiated group was delayed at 12 months after the treatment. On the other hand, there was no difference in the changes in femoral bone mineral density in the two groups. These results suggest that radiotherapy might inhibit the bone mineral loss at the irradiated bone site even when there was an estrogen lack. (author)

  4. Is There a Role for Pelvic Irradiation in Localized Prostate Adenocarcinoma? Update of the Long-Term Survival Results of the GETUG-01 Randomized Study

    Energy Technology Data Exchange (ETDEWEB)

    Pommier, Pascal, E-mail: Pascal.pommier@lyon.unicancer.fr [Department of Radiation Oncology, Centre Léon Bérard, Lyon (France); Chabaud, Sylvie [Department of Clinical Research and Innovation, Centre Léon Bérard, Lyon (France); Lagrange, Jean-Leon [Department of Radiation Oncology, Centre Hospitalo-Universitaire H. Mondor, Créteil (France); Richaud, Pierre [Department of Radiation Oncology, Institut Bergognié, Bordeaux (France); Le Prise, Elisabeth [Department of Radiation Oncology, Centre Eugène Marquis, Rennes (France); Wagner, Jean-Philippe [Department of Radiation Oncology, Institut Andrée Dutreix, Dunkerque (France); Azria, David [Department of Radiation Oncology, Institut de Cancérologie de Montpellier, Montpellier (France); Beckendorf, Veronique [Department of Radiation Oncology, Institut de Cancérologie de Lorraine, Nancy (France); Suchaud, Jean-Philippe [Department of Radiation Oncology, Centre Hospitalier de Roanne, Roanne (France); Bernier, Valerie [Department of Radiation Oncology, Centre Oscar Lambret, Lille (France); Perol, David [Department of Clinical Research and Innovation, Centre Léon Bérard, Lyon (France); Carrie, Christian [Department of Radiation Oncology, Centre Léon Bérard, Lyon (France)

    2016-11-15

    Purpose: To report the long-term results of the French Genitourinary Study Group (GETUG)-01 study in terms of event-free survival (EFS) and overall survival (OS) and assess the potential interaction between hormonotherapy and pelvic nodes irradiation. Patients and Methods: Between December 1998 and June 2004, 446 patients with T1b-T3, N0pNx, M0 prostate carcinoma were randomly assigned to either pelvic nodes and prostate or prostate-only radiation therapy. Patients were stratified into 2 groups: “low risk” (T1-T2 and Gleason score 6 and prostate-specific antigen <3× the upper normal limit of the laboratory) (92 patients) versus “high risk” (T3 or Gleason score >6 or prostate-specific antigen >3× the upper normal limit of the laboratory). Short-term 6-month neoadjuvant and concomitant hormonal therapy was allowed only for high-risk patients. Radiation therapy was delivered with a 3-dimensional conformal technique, using a 4-field technique for the pelvic volume (46 Gy). The total dose recommended to the prostate moved from 66 Gy to 70 Gy during the course of the study. Criteria for EFS included biologic prostate-specific antigen recurrences and/or a local or metastatic progression. Results: With a median follow-up of 11.4 years, the 10-year OS and EFS were similar in the 2 treatment arms. A higher but nonsignificant EFS was observed in the low-risk subgroup in favor of pelvic nodes radiation therapy (77.2% vs 62.5%; P=.18). A post hoc subgroup analysis showed a significant benefit of pelvic irradiation when the risk of lymph node involvement was <15% (Roach formula). This benefit seemed to be limited to patients who did not receive hormonal therapy. Conclusion: Pelvic nodes irradiation did not statistically improve EFS or OS in the whole population but may be beneficial in selected low- and intermediate-risk prostate cancer patients treated with exclusive radiation therapy.

  5. KEK NODAL user's guide

    International Nuclear Information System (INIS)

    Akiyama, Atsuyoshi; Katoh, Tadahiko; Kikutani, Eiji; Koiso, Haruyo; Kurokawa, Shin-ichi; Oide, Katsunobu.

    1984-06-01

    NODAL is an interpreter language for accelerator control developed at CERN SPS and has been used successfully since 1974. At present NODAL or NODAL-like languages are used at DESY PETRA and CERN CPS. At KEK, we have also adopted NODAL for the control of TRISTAN, a 30 GeV x 30 GeV electron-positron colliding beam facility. The KEK version of NODAL has the following improvements on the SPS NODAL: (1) the fast execution speed due to the compiler-interpreter scheme, and (2) the full-screen editing facility. This manual explains how to use the KEK NODAL. It is based on the manual of the SPS NODAL, THE NODAL SYSTEM FOR THE SPS, by M.C. Crowley-Milling and G.C. Shering, CERN 78-07. We have made some additions and modifications to make the manual more appropriate for the KEK NODAL system, paying attention to retaining the good features of the original SPS NODAL manual. We acknowledge Professor M.C. Crowley-Milling, Dr G.C. Shering and CERN for their kind permission for this modification. (author)

  6. KEK NODAL system

    International Nuclear Information System (INIS)

    Kurokawa, S.; Abe, K.; Akiyama, A.; Katoh, T.; Kikutani, E.; Koiso, H.; Kurihara, N.; Oide, K.; Shinomoto, M.

    1985-01-01

    The KEK NODAL system, which is based on the NODAL devised at the CERN SPS, works on an optical-fiber token ring network of twenty-four minicomputers (Hitachi HIDIC 80's) to control the TRISTAN accelerator complex, now being constructed at KEK. KEK NODAL retains main features of the original NODAL: the interpreting scheme, the multi-computer programming facility, and the data-module concept. In addition, it has the following characteristics: fast execution due to the compiler-interpreter method, a multicomputer file system, a full-screen editing facility, and a dynamic linkage scheme of data modules and NODAL functions. The structure of the KEK NODAL system under PMS, a real-time multitasking operating system of HIDIC 80, is described; the NODAL file system is also explained

  7. Male gonadal dose an adjuvant 3-D-pelvic irradiation after anterior resection of rectal cancer. Influence to fertility

    International Nuclear Information System (INIS)

    Piroth, M.D.; Hensley, F.; Wannenmacher, M.; Zierhut, D.

    2003-01-01

    Background: Rectal cancer is a common malignant disease and occurs not infrequently in younger men. We verified the dose to the testes from scattered radiation in adjuvant pelvic irradiation following anterior resection of rectal cancer. Patients and Method: We measured the scattered gonadal dose of 18 patients in vivo with thermoluminescence detectors, which were fixed on four defined points on the scrotum during radiation on three consecutive days. All patients were treated three-dimensionally planned using a three-field box lying in prone position in a bellyboard. A total dose of 50.4 Gy was given in 28 fractions of 1.8 Gy. From 45 up to 50.4 Gy the radiation fields were modified to lateral-opposing fields which were shortened from the top to protect the small bowel. Results: The mean gonadal dose per fraction of all patients was 0.057 Gy (median 0.05 Gy) with a range between 0.035 and 0.114 Gy. The standard deviation was 0.02 Gy. The calculated cumulative mean gonadal dose after 28 fractions was 1.60 Gy (0.98-3.19 Gy). Conclusions: Germinal epithelium is very sensitive to low-dose irradiation, according to a negative fractionation effect. It is known that gonadal total doses of 1 Gy with single doses of 0.03-0.05 Gy can result in a temporary azoospermia with following recovery in most cases. If gonadal total doses exceed 1.5 Gy a substantial increase in irreversible azoospermia must be expected. With respect to the data reported in the literature our measured mean gonadal total dose of 1.60 Gy will lead with high probability to an irreversible infertility. Because of the small number of patients in our study, the data must be interpreted with caution, however, it is very important in patient's informed consent to draw attention to the high risk of infertility. The possibility of sperm cryoconservation should be discussed with the patient. (orig.) [de

  8. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian [Saarland University Medical School, Department of Radiotherapy and Radiation Oncology, Homburg/Saar (Germany)

    2016-02-15

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [German] Das Potenzial der intensitaetsmodulierten Strahlentherapie (IMRT) soll im Rahmen der FDG-PET basierten Bestrahlungsplanung des lokal fortgeschrittenen nichtkleinzelligen Bronchialkarzinoms (LA-NSCLC) fuer 2 Zielvolumenansaetze (Involved-Field-Bestrahlung, IF) sowie elektive Nodalbestrahlung (ENI) geprueft und mit der 3-D-konformalen Strahlentherapie (3-D

  9. Carcinoma of the prostate treated by pelvic node dissection, iodine-125 seed implant and external irradiation; a study of rectal complications

    Energy Technology Data Exchange (ETDEWEB)

    Abadir, R.; Ross, G. Jr.; Weinstein, S.H. (Missouri Univ., Columbia (USA). Hospital and Clinics)

    1984-09-01

    The University of Missouri-Columbia protocol for localised cancer of the prostate calls for pelvic node dissection, 10 000 cGy at the periphery of the prostate from /sup 125/I and 4000 cGy in 20 fractions to the whole pelvis using supervoltage X-ray therapy. Rectal complications were studied in 104 patients; acute and chronic reactions were defined. During external irradiation 54% did not develop diarrhoea, 43% had mild diarrhoea and 3% had severe diarrhoea. In the chronic stage 77% did not have diarrhoea, 12% had delayed, non-distressing rectal bleeding which did not need specific treatment or needed only simple treatment, 7% had prolonged distressing proctitis and 4% had rectal ulceration or recto-urethral fistula necessitating colostomy. Each of the four patients who had colostomy had an additional aetiological factor (arterial disease, pelvic inflammation, additional radiation, pelvic malignancy or second operation). None of the patients entered in the combined brachytherapy and teletherapy programme, and in whom 0.5 cm space was maintained between the closest seed and the rectal mucosa, developed prolonged proctitis.

  10. Topographic distribution of inguinal lymph nodes metastasis: significance in determination of treatment margin for elective inguinal lymph nodes irradiation of low pelvic tumors

    International Nuclear Information System (INIS)

    Wang, C.J.; Chin, Y.Y.; Leung, Stephen Wan; Chen, H.C.; Sun, L.M.; Fang, F.M.

    1996-01-01

    Purpose: To study the distribution of gross inguinal lymph node metastasis and, in particular, its correlation with major pelvic bony structures on a simulation film. Methods and Materials: Thirty-seven cases of low pelvic tumors having gross inguinal lymph node metastasis that were treated with radiation therapy between November 1987 and December 1992 were segregated for study. The patient's nodes were palpated and marked with lead wire before the simulation film was taken. The geometric center of the usually round or elliptical node on the film was assumed to be the origin of the previously uninfested node. A total of 84 such labeled nodes was obtained from these 37 cases. These centers were transferred to and mapped collectively on a new simulation film showing major pelvic bony structures of left hemipelvis and upper femur. Results: Distribution of gross inguinal lymph nodes was found confined to the following area, as related to major pelvic bony structure: laterally, just abutting the tangential line that passes through lateral border of the femoral head; medially: 3 cm away from the body's midline axis; superiorly: 1 cm below the line that joins both upper borders of the femoral head; inferiorly: 2.5 cm below the low borders of ischial tuberosity. According to this rectangular boundary, three nodes were out of field, nine nodes near the border less than 1 cm margin. This area adequately covered 86% (72 of 84) of the studied nodes. Conclusion: Distribution study is important in determining the treatment margin. In general, an additional 1-2 cm beyond the area described above is the recommended treatment margin for elective inguinal lymph nodes irradiation with high confidence level of coverage.

  11. The 3-Dimensional Analysis of the Efficacy of a Belly-Board Device for the Displacement of Small Bowel During Pelvic Irradiation

    International Nuclear Information System (INIS)

    Lee, Kyung Ja

    2008-01-01

    To evaluate the efficacy of a belly-board device (BBD) in reducing the volume of small bowel during four-field pelvic irradiation. Materials and Methods: Twenty-two cancer patients (14 uterine cervical cancer, 6 rectal cancer, and 2 endometrial cancer) scheduled to receive pelvic irradiation were selected for this study. Two sets of CT images were taken with and without the belly-board device using the Siemens 16 channel CT scanner. All patients were set in the prone position. The CT images were transferred to a treatment planning system for dose calculation and volume measurements. The external surfaces of small bowel and the bladder were contoured on all CT scans and the 4-pelvic fields were added. The dose-volume-histogram of the bladder and small bowel, with and without the BBD, were plotted and analyzed. Results: In all patients, the total small bowel volume included in the irradiated fields was reduced when the BBD was used. The mean volume reduction was 35% (range, 1-79%) and was statistically significant (p<0.001). The reduction in small bowel volume receiving 10-100% of the prescribed dose was statistically significant when the BBD was used in all cases. Almost no change in the total bladder volume involved was observed in the field (<8 cc, p=0.762). However, the bladder volume receiving 90% of the prescribed dose was 100% in 15/22 patients (68%) and 90-99% in 7/22 patients (32%) with the BBD. In comparison, the bladder volume receiving 90% of the prescribed dose was 100% in 10/22 patients (45%), 90-99% in 7/22 patients (32%), and 80-89% in 5/22 patients (23%) without the BBD. When the BBD was used, an increase in the bladder volume receiving a high dose range was observed Conclusion: This study shows that the use of a BBD for the treatment of cancer in the pelvic area significantly improves small bowel sparing. However, since the BBD pushed the bladder into the treatment field, the bladder volume receiving the high dose could increase. Therefore it is

  12. Does prophylactic treatment with proteolytic enzymes reduce acute toxicity of adjuvant pelvic irradiation? Results of a double-blind randomized trial

    International Nuclear Information System (INIS)

    Martin, Thomas; Uhder, Kerstin; Kurek, Ralf; Roeddiger, Sandra; Schneider, Lida; Vogt, Hans-Georg; Heyd, Reinhard; Zamboglou, Nikolaos

    2002-01-01

    Purpose: Does prophylactic treatment with proteolytic enzymes reduce acute toxicity of adjuvant pelvic radiotherapy? Material and methods: Fifty-six patients with an indication for adjuvant pelvic irradiation after curative surgery were double-blind randomized. All patients took 3x4 capsules study medication daily during radiotherapy. Twenty-eight patients in the enzyme group (EG) received capsules containing papain, trypsin and chymotrypsin, 28 in the placebo group (PG) received placebo capsules. All patients were irradiated with 5x1.8 Gy weekly to 50.4 Gy using four-field-box technique after CT-based planning. Primary objective was the grade of diarrhea, nausea, vomiting, fatigue and epitheliolysis during radiotherapy. Secondary objectives were the number of supportive medications and treatment interruptions due to acute toxicity. Results: None/mild diarrhea: 43% EG, 64% PG. Moderate/severe diarrhea: 57% EG, 36% PG (P=0.11). Mean duration: 11 days in EG, 10 days in PG. None/mild nausea: 93% EG, 93% PG. Moderate/severe nausea: 7% EG, 7% PG. None/mild vomiting: 100% EG, 97% PG. None/mild fatigue: 82% EG, 93% PG. Moderate/severe fatigue: 18% EG, 7% PG (P=0.23). None/mild epitheliolysis: 75% EG, 93% PG. Moderate/severe epitheliolysis: 25% EG, 7% PG (P=0.16). Treatment interruption (mean days): 2.44 in EG, 1.46 in PG. Number of supportive medication: 29 in EG, 19 in PG. Conclusions: The prophylactic use of proteolytic enzymes does not reduce acute toxicities, treatment interruptions and number of supportive medication and therefore does not improve tolerance of adjuvant pelvic radiotherapy

  13. Details of recurrence sites after elective nodal irradiation (ENI) using 3D-conformal radiotherapy (3D-CRT) combined with chemotherapy for thoracic esophageal squamous cell carcinoma--a retrospective analysis.

    Science.gov (United States)

    Yamashita, Hideomi; Okuma, Kae; Wakui, Reiko; Kobayashi-Shibata, Shino; Ohtomo, Kuni; Nakagawa, Keiichi

    2011-02-01

    To describe patterns of recurrence of elective nodal irradiation (ENI) in definitive chemoradiotherapy (CRT) for thoracic esophageal squamous cell carcinoma (SqCC) using 3D-conformal radiotherapy. One hundred and twenty-six consecutive patients with stages I-IVB thoracic esophageal SqCC newly diagnosed between June 2000 and July 2009 and treated with 3D-CRT in our institution were recruited from our database. Definitive CRT consisted of two cycles of nedaplatin/5FU repeated every 4 weeks, with concurrent radiation therapy of 50-50.4 Gy in 25-28 fractions. Until completion, radiotherapy was delivered to the N1 and M1a lymph nodes as ENI in addition to gross tumor volume. All 126 patients were included in this analysis, and their tumors were staged as follows: T1/T2/T3/T4, 28/18/54/26; N0/N1, 50/76; M0/M1a/M1b, 91/5/30. The mean follow-up period for the 63 surviving patients was 28.3 (±22.8) months. Eighty-seven patients (69%) achieved complete response (CR) without any residual tumor at least once after completion of CRT. After achieving CR, each of 40 patients experienced failures (local=20 and distant=20) and no patient experienced elective nodal failure without having any other site of recurrence. The upper thoracic esophageal carcinoma showed significantly more (34%) relapses at the local site than the middle (9%) or lower thoracic (11%) carcinomas. The 2-year and 3-year overall survival was 56% and 43%, respectively. The 1-year, 2-year and 3-year disease-free survival was 46%, 38% and 33%, respectively. In CRT for esophageal SqCC, ENI was effective for preventing regional nodal failure. The upper thoracic esophageal carcinomas had significantly more local recurrences than the middle or lower thoracic sites. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  14. MR appearance of pelvic hemangiopericytoma

    International Nuclear Information System (INIS)

    Kehagias, D.; Gouliamos, A.; Vlahos, L.

    1999-01-01

    A case of pelvic hemangiopericytoma in a 59-year-old woman is reported. The MR imaging features are presented. The tumor was unresectable and the patient received postoperative irradiation of 4200 cGy on the pelvis. One year after diagnosis, metastasis to a lumbar vertebra was discovered and additional irradiation of 3900 cGy was applied. One year later, CT showed control of the pelvic tumor and its metastasis. (orig.) (orig.)

  15. MR appearance of pelvic hemangiopericytoma

    Energy Technology Data Exchange (ETDEWEB)

    Kehagias, D.; Gouliamos, A.; Vlahos, L. [Dept. of Radiology, University of Athens (Greece)

    1999-02-01

    A case of pelvic hemangiopericytoma in a 59-year-old woman is reported. The MR imaging features are presented. The tumor was unresectable and the patient received postoperative irradiation of 4200 cGy on the pelvis. One year after diagnosis, metastasis to a lumbar vertebra was discovered and additional irradiation of 3900 cGy was applied. One year later, CT showed control of the pelvic tumor and its metastasis. (orig.) (orig.) With 3 figs., 10 refs.

  16. The SOD Mimic, MnTE-2-PyP, Protects from Chronic Fibrosis and Inflammation in Irradiated Normal Pelvic Tissues

    Directory of Open Access Journals (Sweden)

    Shashank Shrishrimal

    2017-11-01

    Full Text Available Pelvic radiation for cancer therapy can damage a variety of normal tissues. In this study, we demonstrate that radiation causes acute changes to pelvic fibroblasts such as the transformation to myofibroblasts and the induction of senescence, which persist months after radiation. The addition of the manganese porphyrin, MnTE-2-PyP, resulted in protection of these acute changes in fibroblasts and this protection persisted months following radiation exposure. Specifically, at two months post-radiation, MnTE-2-PyP inhibited the number of α-smooth muscle actin positive fibroblasts induced by radiation and at six months post-radiation, MnTE-2-PyP significantly reduced collagen deposition (fibrosis in the skin and bladder tissues of irradiated mice. Radiation also resulted in changes to T cells. At two months post-radiation, there was a reduction of Th1-producing splenocytes, which resulted in reduced Th1:Th2 ratios. MnTE-2-PyP maintained Th1:Th2 ratios similar to unirradiated mice. At six months post-radiation, increased T cells were observed in the adipose tissues. MnTE-2-PyP treatment inhibited this increase. Thus, MnTE-2-PyP treatment maintains normal fibroblast function and T cell immunity months after radiation exposure. We believe that one of the reasons MnTE-2-PyP is a potent radioprotector is due to its protection of multiple cell types from radiation damage.

  17. Rescue treatment with interstitial brachytherapy irradiation re very low dose rate iridium-192 (UBT) in inoperable tumors of the oral cavity, oropharynx and nodal: experience of 28 cases in the Gustave-Roussy Institute in Paris

    International Nuclear Information System (INIS)

    Quarneti, A.; Cordova, A.; Barrios, E.; Bonomi, M.; Haie-Meder, C.; Gerbaulet, A.; Eschwege, F.

    2004-01-01

    Purpose: A retrospective analysis of the evolution of 28 patients was performed local recurrences, second tumors and advanced disease in neck nodes in territory previously irradiated, which were re-irradiated using interstitial brachytherapy Ir-192 at very low dose rate (UBT) in the Gustave-Roussy Institute in Paris. Material and Methods: A series of 28 who had received radiation therapy is reported as part of heir initial treatment. 17 patients were treated for local recurrences or second tumors while 11 patients had presented nodal disease. All of them were inoperable. So were treated with interstitial brachytherapy with Ir-192 wires at very low rate dose (UBT), plastic tube technique, re-irradiation regime between 1978 and 1988 Gustave Roussy Institute. Two groups were considered. Group 1 included 17 patients with local recurrences, lesion progression and second tumors. Group 2 included 11 patients with metastatic nodal disease. The mean treatment volume was 45.25 cc, the average dose was 65 Gy, and the average treatment time between the first treatment and re irradiation was 56 months. The average duration of treatment was 14.6 days with a average dose rate of 0.18 Gy / h. After loading technique was used in plastic tubes. They were previously performed to load the simulation with orthogonal plates, false sources and provisional dosimetry. Late toxicity was assessed according to the RTOG score. Local control rates were studied complications and survive on some factors of possible prognostic significance. The statistical analysis of significance was performed by the method and log rank test were prepared survival curves and disease-free survival by Kaplan-Meier. Results: 2 groups were analyzed separately. In group 1, procedures were performed 17 UBTD and method of low dose rate (LDR). 10 of 17 patients achieved complete responses. The patient that the procedure was performed at low dose rate also achieved a complete response. In 3 cases, no response is not

  18. Re-irradiation: Outcome, cumulative dose and toxicity in patients retreated with stereotactic radiotherapy in the abdominal or pelvic region

    NARCIS (Netherlands)

    H. Abusaris (Huda); M.S. Hoogeman (Mischa); J.J.M.E. Nuyttens (Joost)

    2012-01-01

    textabstractThe purpose of the present study was to explore the outcome, cumulative dose in tumor and organs at risk and toxicity after extra-cranial stereotactic re-irradiation. Twenty-seven patients were evaluated who had been re-irradiated with stereotactic body radiotherapy (SBRT) after

  19. Nodal-chain metals.

    Science.gov (United States)

    Bzdušek, Tomáš; Wu, QuanSheng; Rüegg, Andreas; Sigrist, Manfred; Soluyanov, Alexey A

    2016-10-06

    The band theory of solids is arguably the most successful theory of condensed-matter physics, providing a description of the electronic energy levels in various materials. Electronic wavefunctions obtained from the band theory enable a topological characterization of metals for which the electronic spectrum may host robust, topologically protected, fermionic quasiparticles. Many of these quasiparticles are analogues of the elementary particles of the Standard Model, but others do not have a counterpart in relativistic high-energy theories. A complete list of possible quasiparticles in solids is lacking, even in the non-interacting case. Here we describe the possible existence of a hitherto unrecognized type of fermionic excitation in metals. This excitation forms a nodal chain-a chain of connected loops in momentum space-along which conduction and valence bands touch. We prove that the nodal chain is topologically distinct from previously reported excitations. We discuss the symmetry requirements for the appearance of this excitation and predict that it is realized in an existing material, iridium tetrafluoride (IrF 4 ), as well as in other compounds of this class of materials. Using IrF 4 as an example, we provide a discussion of the topological surface states associated with the nodal chain. We argue that the presence of the nodal-chain fermions will result in anomalous magnetotransport properties, distinct from those of materials exhibiting previously known excitations.

  20. Post Pelvic Radiotherapy Bony Changes

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Seung Jae [Samsung Medical Center, Seoul (Korea, Republic of)

    2009-03-15

    There has been recent interest in radiation-induced bone injury in clinical conditions, especially for pelvic insufficiency fracture (PIF). A PIF is caused by the effect of normal or physiological stress on bone with demineralization and decreased elastic resistance. Pelvic radiotherapy (RT) can also contribute to the development of a PIF. A PIF has been regarded as a rare complication with the use of megavoltage equipment. However, recent studies have reported the incidence of PIFs as 8.2{approx}20% after pelvic RT in gynecological patients, an incidence that was higher than previously believed. The importance of understanding a PIF lies in the potential for misdiagnosis as a bony metastasis. If patients complain of pelvic pain after whole-pelvis radiation therapy, the presence of a PIF must be considered in the differential diagnosis. The use of multibeam arrangements and conformal RT to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture. In addition to a PIF, osteonecrosis and avascular necrosis of the femoral head can develop after radiation therapy. Osteoradionecrosis of the pelvic bone is a clinical diagnostic challenge that must be differentiated from an osseous metastasis. A post-radiation bone sarcoma can result as a long-term sequela of pelvic irradiation for uterine cervical cancer.

  1. Moderate hypofractionated radiotherapy with volumetric modulated arc therapy and simultaneous integrated boost for pelvic irradiation in prostate cancer.

    Science.gov (United States)

    Franzese, C; Fogliata, A; D'Agostino, G R; Di Brina, L; Comito, T; Navarria, P; Cozzi, L; Scorsetti, M

    2017-07-01

    The optimal treatment for unfavourable intermediate/high-risk prostate cancer is still debated. In the present study, the pattern of toxicity and early clinical outcome of patients with localized prostate cancer was analyzed. A cohort of 90 patients treated on pelvic lymph nodes from 2010 to 2015 was selected. All patients were treated with Volumetric Modulated Arc Therapy (VMAT), and Simultaneous integrated boost (SIB) in 28 fractions; the prostate, the seminal vesicle and the pelvic lymph node received total doses of 74.2, 65.5, and 51.8 Gy, respectively. End points were the detection of acute and late toxicities graded according to the Common Toxicity Criteria CTCAE version 3, evaluating the rectal, genito-urinary and gastro-intestinal toxicity. Correlation of OARs dose parameters and related toxicities was explored. Preliminary overall survival and Progression-free survival (PFS) were evaluated. With a median follow-up of 25 months, no interruptions for treatment-related toxicity were recorded. Univariate analysis among dosimetric data and acute toxicities showed no correlations. Regarding late toxicity: the dose received by a rectal volume of 90 cm 3 was found to be significant for toxicity prediction (p = 0.024). PFS was 90.6% and 60.2% at 2 and 4 years, respectively. PFS correlates with age (p = 0.011) and Gleason score (p = 0.011). Stratifying the PSA nadir in quartiles, its value was significant (p = 0.016) in predicting PFS, showing a reduction of PFS of 2 months for each PSA-nadir increase of 0.1 ng/ml. HRT with VMAT and SIB on the whole pelvis in unfavourable prostate cancer patients is effective with a mild pattern of toxicity.

  2. Pelvic Pain

    Science.gov (United States)

    ... OLPP) Office of Science Policy, Reporting, and Program Analysis (OSPRA) Division of Extramural Research (DER) Extramural Scientific ... treat my pain? Can pelvic pain affect my emotional well-being? How can I cope with long- ...

  3. Pelvic Exam

    Science.gov (United States)

    ... each step so that nothing comes as a surprise to you. After the pelvic exam After the ... Clinic does not endorse any of the third party products and services advertised. Advertising and sponsorship policy ...

  4. Experimental discovery of nodal chains

    Science.gov (United States)

    Yan, Qinghui; Liu, Rongjuan; Yan, Zhongbo; Liu, Boyuan; Chen, Hongsheng; Wang, Zhong; Lu, Ling

    2018-05-01

    Three-dimensional Weyl and Dirac nodal points1 have attracted widespread interest across multiple disciplines and in many platforms but allow for few structural variations. In contrast, nodal lines2-4 can have numerous topological configurations in momentum space, forming nodal rings5-9, nodal chains10-15, nodal links16-20 and nodal knots21,22. However, nodal lines are much less explored because of the lack of an ideal experimental realization23-25. For example, in condensed-matter systems, nodal lines are often fragile to spin-orbit coupling, located away from the Fermi level, coexist with energy-degenerate trivial bands or have a degeneracy line that disperses strongly in energy. Here, overcoming all these difficulties, we theoretically predict and experimentally observe nodal chains in a metallic-mesh photonic crystal having frequency-isolated linear band-touching rings chained across the entire Brillouin zone. These nodal chains are protected by mirror symmetry and have a frequency variation of less than 1%. We use angle-resolved transmission measurements to probe the projected bulk dispersion and perform Fourier-transformed field scans to map out the dispersion of the drumhead surface state. Our results establish an ideal nodal-line material for further study of topological line degeneracies with non-trivial connectivity and consequent wave dynamics that are richer than those in Weyl and Dirac materials.

  5. Outcome According to Elective Pelvic Radiation Therapy in Patients With High-Risk Localized Prostate Cancer: A Secondary Analysis of the GETUG 12 Phase 3 Randomized Trial.

    Science.gov (United States)

    Blanchard, Pierre; Faivre, Laura; Lesaunier, François; Salem, Naji; Mesgouez-Nebout, Nathalie; Deniau-Alexandre, Elisabeth; Rolland, Frédéric; Ferrero, Jean-Marc; Houédé, Nadine; Mourey, Loïc; Théodore, Christine; Krakowski, Ivan; Berdah, Jean-François; Baciuchka, Marjorie; Laguerre, Brigitte; Davin, Jean-Louis; Habibian, Muriel; Culine, Stéphane; Laplanche, Agnès; Fizazi, Karim

    2016-01-01

    The role of pelvic elective nodal irradiation (ENI) in the management of prostate cancer is controversial. This study analyzed the role of pelvic radiation therapy (RT) on the outcome in high-risk localized prostate cancer patients included in the Groupe d'Etude des Tumeurs Uro-Genitales (GETUG) 12 trial. Patients with a nonpretreated high-risk localized prostate cancer and a staging lymphadenectomy were randomly assigned to receive either goserelin every 3 months for 3 years and 4 cycles of docetaxel plus estramustine or goserelin alone. Local therapy was administered 3 months after the start of systemic treatment. Performance of pelvic ENI was left to the treating physician. Only patients treated with primary RT were included in this analysis. The primary endpoint was biochemical progression-free survival (bPFS). A total of 413 patients treated from 2002 to 2006 were included, of whom 358 were treated using primary RT. A total of 208 patients received pelvic RT and 150 prostate-only RT. Prostate-specific antigen (PSA) concentration, Gleason score, or T stage did not differ according to performance of pelvic RT; pN+ patients more frequently received pelvic RT than pN0 patients (PENI in multivariate analysis (HR: 1.10 [95% CI: 0.78-1.55], P=.60), even when analysis was restricted to pN0 patients (HR: 0.88 [95% CI: 0.59-1.31], P=.53). Pelvic ENI was not associated with increased acute or late patient reported toxicity. This unplanned analysis of a randomized trial failed to demonstrate a benefit of pelvic ENI on bPFS in high-risk localized prostate cancer patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Pelvic Actinomycosis

    Directory of Open Access Journals (Sweden)

    Alejandra García-García

    2017-01-01

    Full Text Available Introduction. Actinomycosis is a chronic bacterial infection caused by Actinomyces, Gram-positive anaerobic bacteria. Its symptomatology imitates some malignant pelvic tumours, tuberculosis, or nocardiosis, causing abscesses and fistulas. Actinomycoses are opportunistic infections and require normal mucous barriers to be altered. No epidemiological studies have been conducted to determine prevalence or incidence of such infections. Objective. To analyse the clinical cases of pelvic actinomycosis reported worldwide, to update the information about the disease. Methods. A systematic review of worldwide pelvic actinomycosis cases between 1980 and 2014 was performed, utilising the PubMed, Scopus, and Google Scholar databases. The following information was analysed: year, country, type of study, number of cases, use of intrauterine device (IUD, final and initial diagnosis, and method of diagnosis. Results. 63 articles met the search criteria, of which 55 reported clinical cases and 8 reported cross-sectional studies. Conclusions. Pelvic actinomycosis is confusing to diagnose and should be considered in the differential diagnosis of pelvic chronic inflammatory lesions. It is commonly diagnosed through a histological report, obtained after a surgery subsequent to an erroneous initial diagnosis. A bacterial culture in anaerobic medium could be useful for the diagnosis but requires a controlled technique and should be performed using specialised equipment.

  7. Avoided intersections of nodal lines

    International Nuclear Information System (INIS)

    Monastra, Alejandro G; Smilansky, Uzy; Gnutzmann, Sven

    2003-01-01

    We consider real eigenfunctions of the Schroedinger operator in 2D. The nodal lines of separable systems form a regular grid, and the number of nodal crossings equals the number of nodal domains. In contrast, for wavefunctions of non-integrable systems nodal intersections are rare, and for random waves, the expected number of intersections in any finite area vanishes. However, nodal lines display characteristic avoided crossings which we study in this work. We define a measure for the avoidance range and compute its distribution for the random wave ensemble. We show that the avoidance range distribution of wavefunctions of chaotic systems follows the expected random wave distributions, whereas for wavefunctions of classically integrable but quantum non-separable systems, the distribution is quite different. Thus, the study of the avoidance distribution provides more support to the conjecture that nodal structures of chaotic systems are reproduced by the predictions of the random wave ensemble

  8. A comparative dosimetric study of conventional, conformal and intensity-modulated radiotherapy in postoperative pelvic irradiation of cervical cancer

    International Nuclear Information System (INIS)

    Li Bin; An Jusheng; Wu Lingying; Huang Manni; Gao Juzhen; Xu Yingjie; Dai Jianrong

    2008-01-01

    Objective: To evaluate target-volume coverage and organ at risk (OAR) protection achieved with conventional radiotherapy (CRT), three dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy(IMRT) through dosimetric comparison in patients with cervical cancer after hysterectomy. Methods: The planning CT scans of 10 patients treated with pelvic radiation after hysterectomy for cervical cancer were used to generate CRT, 3DCRT and IMRT plans for this study. Clinical target volume(CTV) was contoured on the individual axial CT slices of every patient. The CTV was then uniformly expanded by 1.0 cm to create the planning target volume (PTV). The small bowel, rectum, bladder, bone marrow, ovaries, and femoral heads were outlined for the organ at risk (OAR) evaluation. The CRT, 3DCRT and IMRT plans were generated using commercial planning software. CRT plan was prescribed to deliver 45 Gy to the reference point, while IMRT and 3DCRT plans were 45 Gy to 95% of the PTV. Isodose line and dose volume histograms(DVH) were used to evaluate the dose distribution in CTV and OAR. Results: For 10 patients, the average volume of CTV receiving the prescribed dose of CRT was significantly lower than 3DCRT(Q=8.27, P<0.01) and IMRT(Q=8.37, P<0.01), respectively. Comparing with the CRT plan, the 3DCRT and IMRT plans notably reduced the volume of bowel at 30 and 45 Gy levels. The IMRT plan significantly spared rectum and bladder at 30 and 45 Gy levels comparing with the CRT (P<0.01) and 3DCRT(P<0.05) plans, while the 3DCRT plan significantly spared rectum and bladder at 45 Gy level comparing with the CRT(P<0.01) plans. For 4 patients with ovarian transposition, the average doses of ovary over 3 Gy were 2 patients with the 3 DCRT and IMRT plans, and 2 with all three plans. Conclusions: IMRT and 3DCRT are superior to CRT in improving dose coverage of target volume and sparing of OAR, while IMRT being the best. The superiority of IMRT and 3DCRT is obvious in sparing

  9. Long-Term Follow-Up of Preoperative Pelvic Radiation Therapy and Concomitant Boost Irradiation in Locally Advanced Rectal Cancer Patients: A Multi-Institutional Phase II Study (KROG 04-01)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hoon [Department of Radiation Oncology, Seoul St. Mary' s Hospital, College of Medicine, Catholic University of Korea, Seoul (Korea, Republic of); Department of Radiation Oncology, St. Vincent' s Hospital, Catholic University of Korea, Suwon (Korea, Republic of); Kim, Dae Yong [Center for Colorectal Cancer, Research Institute and Hospital, National Cancer Center, Go-Yang (Korea, Republic of); Nam, Taek-Keun [Department of Radiation Oncology, Chonnam National University Hospital, Hwa-Sun (Korea, Republic of); Yoon, Sei-Chul [Department of Radiation Oncology, Seoul St. Mary' s Hospital, College of Medicine, Catholic University of Korea, Seoul (Korea, Republic of); Lee, Doo Seok [Department of Colorectal Surgery, Daehang Hospital, Seoul (Korea, Republic of); Park, Ji Won; Oh, Jae Hwan; Chang, Hee Jin [Center for Colorectal Cancer, Research Institute and Hospital, National Cancer Center, Go-Yang (Korea, Republic of); Yoon, Mee Sun; Jeong, Jae-Uk [Department of Radiation Oncology, Chonnam National University Hospital, Hwa-Sun (Korea, Republic of); Jang, Hong Seok, E-mail: hsjang11@catholic.ac.kr [Department of Radiation Oncology, Seoul St. Mary' s Hospital, College of Medicine, Catholic University of Korea, Seoul (Korea, Republic of)

    2012-11-15

    Purpose: To perform a prospective phase II study to investigate the efficacy and safety of preoperative pelvic radiation therapy and concomitant small-field boost irradiation with 5-fluorouracil and leucovorin for 5 weeks in locally advanced rectal cancer patients. Methods and Materials: Sixty-nine patients with locally advanced, nonmetastatic, mid-to-lower rectal cancer were prospectively enrolled. They had received preoperative chemoradiation therapy and total mesorectal excision. Pelvic radiation therapy of 43.2 Gy in 24 fractions plus concomitant boost radiation therapy of 7.2 Gy in 12 fractions was delivered to the pelvis and tumor bed for 5 weeks. Two cycles of 5-fluorouracil and leucovorin were administered for 3 days in the first and fifth week of radiation therapy. The pathologic response, survival outcome, and treatment toxicity were evaluated for the study endpoints. Results: Of 69 patients, 8 (11.6%) had a pathologically complete response. Downstaging rates were 40.5% for T classification and 68.1% for N classification. At the median follow-up of 69 months, 36 patients have been followed up for more than 5 years. The 5-year disease-free survival (DFS) and overall survival rates were 66.0% and 75.3%, respectively. Higher pathologic T (P = .045) and N (P = .032) classification were significant adverse prognostic factors for DFS, and high-grade histology was an adverse prognostic factor for both DFS (P = .025) and overall survival (P = .031) on the multivariate analysis. Fifteen patients (21.7%) experienced grade 3 or 4 acute toxicity, and 7 patients (10.1%) had long-term toxicity. Conclusion: Preoperative pelvic radiation therapy with concomitant boost irradiation with 5-fluorouracil and leucovorin for 5 weeks showed acceptable acute and long-term toxicities. However, the benefit of concomitant small-field boost irradiation for 5 weeks in rectal cancer patients was not demonstrated beyond conventional irradiation for 6 weeks in terms of tumor response and

  10. Occult Pelvic Lymph Node Involvement in Bladder Cancer: Implications for Definitive Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Goldsmith, Benjamin; Baumann, Brian C.; He, Jiwei; Tucker, Kai; Bekelman, Justin; Deville, Curtiland; Vapiwala, Neha [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Vaughn, David; Keefe, Stephen M. [Department of Medical Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Guzzo, Thomas; Malkowicz, S. Bruce [Department of Urology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Christodouleas, John P., E-mail: christojo@uphs.upenn.edu [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2014-03-01

    Purpose: To inform radiation treatment planning for clinically staged, node-negative bladder cancer patients by identifying clinical factors associated with the presence and location of occult pathologic pelvic lymph nodes. Methods and Materials: The records of patients with clinically staged T1-T4N0 urothelial carcinoma of the bladder undergoing radical cystectomy and pelvic lymphadenectomy at a single institution were reviewed. Logistic regression was used to evaluate associations between preoperative clinical variables and occult pathologic pelvic or common iliac lymph nodes. Percentages of patient with involved lymph node regions entirely encompassed within whole bladder (perivesicular nodal region), small pelvic (perivesicular, obturator, internal iliac, and external iliac nodal regions), and extended pelvic clinical target volume (CTV) (small pelvic CTV plus common iliac regions) were calculated. Results: Among 315 eligible patients, 81 (26%) were found to have involved pelvic lymph nodes at the time of surgery, with 38 (12%) having involved common iliac lymph nodes. Risk of occult pathologically involved lymph nodes did not vary with clinical T stage. On multivariate analysis, the presence of lymphovascular invasion (LVI) on preoperative biopsy was significantly associated with occult pelvic nodal involvement (odds ratio 3.740, 95% confidence interval 1.865-7.499, P<.001) and marginally associated with occult common iliac nodal involvement (odds ratio 2.307, 95% confidence interval 0.978-5.441, P=.056). The percentages of patients with involved lymph node regions entirely encompassed by whole bladder, small pelvic, and extended pelvic CTVs varied with clinical risk factors, ranging from 85.4%, 95.1%, and 100% in non-muscle-invasive patients to 44.7%, 71.1%, and 94.8% in patients with muscle-invasive disease and biopsy LVI. Conclusions: Occult pelvic lymph node rates are substantial for all clinical subgroups, especially patients with LVI on biopsy. Extended

  11. Analysis of incidence and nursing care for oral adverse events induced by chest or pelvic irradiation combined with chemotherapy

    International Nuclear Information System (INIS)

    Seki, Miyuki; Kitada, Yoko; Ishikawa, Hitoshi

    2010-01-01

    The aim of this study was to clarify incidence and severity of oral adverse events induced by chemoradiotherapy and to explore efficient nursing-intervention or oral-care for the oral complications. Seventy-nine subjects who were treated with chemoradiotherapy at the radiation oncology unit of Gunma University Hospital were retrospectively analyzed using collected data from patients' medical chart including location of tumor, details of treatment, incidence and care of oral adverse events. Oral adverse events occurred in 7 (9%) of 79 patients. The complication rate in patients with lung or esophageal cancer was much higher than that with rectal or cervical cancer. All patients with the events received a total irradiation dose of 60 Gy in 30 fractions or higher. Oral mucositis was observed in 5 patients given antimetabolic chemotherapeutic agents, but they were successfully treated with steroids and/or gargles. Our results suggest that early intervention of oral care may reduce risks of developing severe oral adverse effects induced by chemoradiotherapy. (author)

  12. The SINTRAN III NODAL system

    International Nuclear Information System (INIS)

    Skaali, T.B.

    1980-10-01

    NODAL is a high level programming language based on FOCAL and SNOBOL4, with some influence from BASIC. The language was developed to operate on the computer network controlling the SPS accelerator at CERN. NODAL is an interpretive language designed for interactive use. This is the most important aspect of the language, and is reflected in its structure. The interactive facilities make it possible to write, debug and modify programs much faster than with compiler based languages like FORTRAN and ALGOL. Apart from a few minor modifications, the basic part of the Oslo University NODAL system does not differ from the CERN version. However, the Oslo University implementation has been expanded with new functions which enable the user to execute many of the SINTRAN III monitor calls from the NODAL level. In particular the most important RT monitor calls have been implemented in this way, a property which renders possible the use of NODAL as a RT program administrator. (JIW)

  13. The Different Volume Effects of Small-Bowel Toxicity During Pelvic Irradiation Between Gynecologic Patients With and Without Abdominal Surgery: A Prospective Study With Computed Tomography-Based Dosimetry

    International Nuclear Information System (INIS)

    Huang, E.-Y.; Sung, C.-C.; Ko, S.-F.; Wang, C.-J.; Yang, Kuender D.

    2007-01-01

    Purpose: To evaluate the effect of abdominal surgery on the volume effects of small-bowel toxicity during whole-pelvic irradiation in patients with gynecologic malignancies. Methods and Materials: From May 2003 through November 2006, 80 gynecologic patients without (Group I) or with (Group II) prior abdominal surgery were analyzed. We used a computed tomography (CT) planning system to measure the small-bowel volume and dosimetry. We acquired the range of small-bowel volume in 10% (V10) to 100% (V100) of dose, at 10% intervals. The onset and grade of diarrhea during whole-pelvic irradiation were recorded as small-bowel toxicity up to 39.6 Gy in 22 fractions. Results: The volume effect of Grade 2-3 diarrhea existed from V10 to V100 in Group I patients and from V60 to V100 in Group II patients on univariate analyses. The V40 of Group I and the V100 of Group II achieved most statistical significance. The mean V40 was 281 ± 27 cm 3 and 489 ± 34 cm 3 (p 3 and 132 ± 19 cm 3 (p = 0.003). Multivariate analyses revealed that V40 (p = 0.001) and V100 (p = 0.027) were independent factors for the development of Grade 2-3 diarrhea in Groups I and II, respectively. Conclusions: Gynecologic patients without and with abdominal surgery have different volume effects on small-bowel toxicity during whole-pelvic irradiation. Low-dose volume can be used as a predictive index of Grade 2 or greater diarrhea in patients without abdominal surgery. Full-dose volume is more important than low-dose volume for Grade 2 or greater diarrhea in patients with abdominal surgery

  14. Impact of [18F]fluorodeoxyglucose PET-CT staging on treatment planning in radiotherapy incorporating elective nodal irradiation for non-small-cell lung cancer: a prospective study.

    Science.gov (United States)

    Kolodziejczyk, Milena; Kepka, Lucyna; Dziuk, Miroslaw; Zawadzka, Anna; Szalus, Norbert; Gizewska, Agnieszka; Bujko, Krzysztof

    2011-07-15

    To evaluate prospectively how positron emission tomography (PET) information changes treatment plans for non-small-cell lung cancer (NSCLC) patients receiving or not receiving elective nodal irradiation (ENI). One hundred consecutive patients referred for curative radiotherapy were included in the study. Treatment plans were carried out with CT data sets only. For stage III patients, mediastinal ENI was planned. Then, patients underwent PET-CT for diagnostic/planning purposes. PET/CT was fused with the CT data for final planning. New targets were delineated. For stage III patients with minimal N disease (N0-N1, single N2), the ENI was omitted in the new plans. Patients were treated according to the PET-based volumes and plans. The gross tumor volume (GTV)/planning tumor volume (PTV) and doses for critical structures were compared for both data sets. The doses for areas of potential geographical misses derived with the CT data set alone were compared in patients with and without initially planned ENI. In the 75 patients for whom the decision about curative radiotherapy was maintained after PET/CT, there would have been 20 cases (27%) with potential geographical misses by using the CT data set alone. Among them, 13 patients would receive ENI; of those patients, only 2 patients had the PET-based PTV covered by 90% isodose by using the plans based on CT alone, and the mean of the minimum dose within the missed GTV was 55% of the prescribed dose, while for 7 patients without ENI, it was 10% (p = 0.006). The lung, heart, and esophageal doses were significantly lower for plans with ENI omission than for plans with ENI use based on CT alone. PET/CT should be incorporated in the planning of radiotherapy for NSCLC, even in the setting of ENI. However, if PET/CT is unavailable, ENI may to some extent compensate for an inadequate dose coverage resulting from diagnostic uncertainties. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Impact of [18F]Fluorodeoxyglucose PET-CT Staging on Treatment Planning in Radiotherapy Incorporating Elective Nodal Irradiation for Non-Small-Cell Lung Cancer: A Prospective Study

    International Nuclear Information System (INIS)

    Kolodziejczyk, Milena; Kepka, Lucyna; Dziuk, Miroslaw; Zawadzka, Anna; Szalus, Norbert; Gizewska, Agnieszka; Bujko, Krzysztof

    2011-01-01

    Purpose: To evaluate prospectively how positron emission tomography (PET) information changes treatment plans for non-small-cell lung cancer (NSCLC) patients receiving or not receiving elective nodal irradiation (ENI). Methods and Materials: One hundred consecutive patients referred for curative radiotherapy were included in the study. Treatment plans were carried out with CT data sets only. For stage III patients, mediastinal ENI was planned. Then, patients underwent PET-CT for diagnostic/planning purposes. PET/CT was fused with the CT data for final planning. New targets were delineated. For stage III patients with minimal N disease (N0-N1, single N2), the ENI was omitted in the new plans. Patients were treated according to the PET-based volumes and plans. The gross tumor volume (GTV)/planning tumor volume (PTV) and doses for critical structures were compared for both data sets. The doses for areas of potential geographical misses derived with the CT data set alone were compared in patients with and without initially planned ENI. Results: In the 75 patients for whom the decision about curative radiotherapy was maintained after PET/CT, there would have been 20 cases (27%) with potential geographical misses by using the CT data set alone. Among them, 13 patients would receive ENI; of those patients, only 2 patients had the PET-based PTV covered by 90% isodose by using the plans based on CT alone, and the mean of the minimum dose within the missed GTV was 55% of the prescribed dose, while for 7 patients without ENI, it was 10% (p = 0.006). The lung, heart, and esophageal doses were significantly lower for plans with ENI omission than for plans with ENI use based on CT alone. Conclusions: PET/CT should be incorporated in the planning of radiotherapy for NSCLC, even in the setting of ENI. However, if PET/CT is unavailable, ENI may to some extent compensate for an inadequate dose coverage resulting from diagnostic uncertainties.

  16. NODAL interpreter for CP/M

    International Nuclear Information System (INIS)

    Oide, Katsunobu.

    1982-11-01

    A NODAL interpreter which works under CP/M operating system is made for microcomputers. This interpreter language named NODAL-80 has a similar structure to the NODAL of SPS, but its commands, variables, and expressions are modified to increase the flexibility of programming. NODAL-80 also uses a simple intermediate code to make the execution speed fast without imposing any restriction on the dynamic feature of NODAL language. (author)

  17. Pelvic Chondroblastoma

    International Nuclear Information System (INIS)

    Romero Rojas, Alfredo Ernesto; Restrepo Escobar, Ligia Ines; Melo Uribe, Mario Alexander

    2009-01-01

    This article describes the case of a 24-year old woman with a pelvic chondroblastoma localized at the top of the right iliac crest, with six months of evolution and progressive growth. X-rays revealed an osteolytic lesion with heterogeneous density, extending toward soft tissue; the histopathologic study provided evidence of chondroblastoma. Chondroblastomas are benign bone tumors producers of cartilage which appears in the long bone epiphysis of young people. Nearly 75% of such tumors affect the long bones, principally the femur, the tibia, and the humerus; exceptions include those in the flat craniofacial bones and the pelvis bones. Chondroblastomas have distinct radiological and histopathologic characteristics, and despite their benign biological behavior, can cause elevated morbidity among patients due to their localization and being treated exclusively with surgery.

  18. Radiotherapy of adult nodal non Hodgkin's lymphoma

    International Nuclear Information System (INIS)

    Gamen, G.; Thirion, P.

    1999-01-01

    The role of radiotherapy in the treatment of nodal non-Hodgkin's lymphoma has been modified by the introduction of efficient chemotherapy and the development of different pathological classifications. The recommended treatment of early-stage aggressive lymphomas is primarily a combination chemotherapy. The interest of adjuvant radiotherapy remains unclear and has to be established through large prospective trials. If radiation therapy has to be delivered, the historical results of exclusive radiation therapy showed that involved-fields and a dose of 35-40 Gy (daily fraction of 1.8 Gy, 5 days a week) are the optimal schedule. The interest of radiotherapy in the treatment of advanced-stage aggressive lymphoma is yet to be proven. Further studies had to stratify localized stages according to the factors of the International Prognostic Index. For easy-stage low-grade lymphoma, radiotherapy remains the standard treatment. However, the appropriate technique to use is controversial. Involved-field irradiation at a dose of 35 Gy seems to be the optimal schedule, providing a 10 year disease-free survival rate of 50 % and no major toxicity. There is no standard indication of radiotherapy in the treatment advanced-stage low-grade lymphoma. For 'new' nodal lymphoma's types, the indication of radiotherapy cannot be established (mantle-zone lymphoma, marginal zone B-cell lymphoma) or must take into account the natural history (Burkitt's lymphoma, peripheral T-cell lymphoma) and the sensibility to others therapeutic methods. (authors)

  19. Nodal metastasis in thyroid cancer

    International Nuclear Information System (INIS)

    Samuel, A.M.

    1999-01-01

    The biological behavior and hence the prognosis of thyroid cancer (TC) depends among other factors on the extent of spread of the disease outside the thyroid bed. This effect is controversial, especially for nodal metastasis of well differentiated thyroid carcinoma (WDC). Nodal metastasis at the time of initial diagnosis behaves differently depending on the histology, age of the patient, presence of extrathyroidal extension, and the sex of the individual. The type of the surgery, administration of 131 I and thyroxin suppression also to some extent influence the rate of recurrence and mortality. Experience has shown that it is not as innocuous as a small intrathyroidal tumor without any invasion outside the thyroid bed and due consideration should be accorded to the management strategies for handling patients with nodal metastasis

  20. The adjoint variational nodal method

    International Nuclear Information System (INIS)

    Laurin-Kovitz, K.; Lewis, E.E.

    1993-01-01

    The widespread use of nodal methods for reactor core calculations in both diffusion and transport approximations has created a demand for the corresponding adjoint solutions as a prerequisite for performing perturbation calculations. With some computational methods, however, the solution of the adjoint problem presents a difficulty; the physical adjoint obtained by discretizing the adjoint equation is not the same as the mathematical adjoint obtained by taking the transpose of the coefficient matrix, which results from the discretization of the forward equation. This difficulty arises, in particular, when interface current nodal methods based on quasi-one-dimensional solution of the diffusion or transport equation are employed. The mathematical adjoint is needed to perform perturbation calculations. The utilization of existing nodal computational algorithms, however, requires the physical adjoint. As a result, similarity transforms or related techniques must be utilized to relate physical and mathematical adjoints. Thus far, such techniques have been developed only for diffusion theory

  1. Outcome According to Elective Pelvic Radiation Therapy in Patients With High-Risk Localized Prostate Cancer: A Secondary Analysis of the GETUG 12 Phase 3 Randomized Trial

    Energy Technology Data Exchange (ETDEWEB)

    Blanchard, Pierre, E-mail: pierre.blanchard@gustaveroussy.fr [Radiation Oncology, Gustave Roussy Cancer Center, Villejuif (France); University of Paris-Sud, Cancer Campus, Villejuif (France); Faivre, Laura [Biostatistics, Gustave Roussy Cancer Center, Villejuif (France); Lesaunier, François [Radiation Oncology, Centre Francois Baclesse, Caen (France); Salem, Naji [Radiation Oncology, Institut Paoli Calmette, Marseille (France); Mesgouez-Nebout, Nathalie [Radiation Oncology, Institut de Cancérologie de l' Ouest, Angers (France); Deniau-Alexandre, Elisabeth [Centre Hospitalier La Roche sur Yon, La Roche sur Yon (France); Rolland, Frédéric [Medical Oncology, Institut de Cancérologie de l' Ouest, Nantes (France); Ferrero, Jean-Marc [Medical Oncology, Centre Antoine Lacassagne, Nice (France); Houédé, Nadine [Medical Oncology, Institut Bergonié, Bordeaux (France); Mourey, Loïc [Institut Claudius Regaud, Toulouse (France); Théodore, Christine [Hospital Foch, Suresnes (France); Krakowski, Ivan [Centre Alexis Vautrin, Vandoeuvre-lès-Nancy (France); Berdah, Jean-François [Clinique Sainte Marguerite, Hyeres (France); Baciuchka, Marjorie [Centre Hospitalier de la Timone, Marseille (France); Laguerre, Brigitte [Centre Eugène Marquis, Rennes (France); Davin, Jean-Louis [Clinique Sainte Catherine, Avignon (France); Habibian, Muriel [R& D UNICANCER, Paris (France); UNICANCER, Paris (France); Culine, Stéphane [Department of Medical Oncology, Hopital Saint-Louis, APHP, Paris (France); and others

    2016-01-01

    Purpose: The role of pelvic elective nodal irradiation (ENI) in the management of prostate cancer is controversial. This study analyzed the role of pelvic radiation therapy (RT) on the outcome in high-risk localized prostate cancer patients included in the Groupe d'Etude des Tumeurs Uro-Genitales (GETUG) 12 trial. Methods and Materials: Patients with a nonpretreated high-risk localized prostate cancer and a staging lymphadenectomy were randomly assigned to receive either goserelin every 3 months for 3 years and 4 cycles of docetaxel plus estramustine or goserelin alone. Local therapy was administered 3 months after the start of systemic treatment. Performance of pelvic ENI was left to the treating physician. Only patients treated with primary RT were included in this analysis. The primary endpoint was biochemical progression-free survival (bPFS). Results: A total of 413 patients treated from 2002 to 2006 were included, of whom 358 were treated using primary RT. A total of 208 patients received pelvic RT and 150 prostate-only RT. Prostate-specific antigen (PSA) concentration, Gleason score, or T stage did not differ according to performance of pelvic RT; pN+ patients more frequently received pelvic RT than pN0 patients (P<.0001). Median follow-up was 8.8 years. In multivariate analysis, bPFS was negatively impacted by pN stage (hazard ratio [HR]: 2.52 [95% confidence interval [CI]: 1.78-3.54], P<.0001), Gleason score 8 or higher (HR: 1.41 [95% CI: 1.03-1.93], P=.033) and PSA higher than 20 ng/mL (HR: 1.41 [95% CI: 1.02-1.96], P=.038), and positively impacted by the use of chemotherapy (HR: 0.66 [95% CI: 0.48-0.9], P=.009). There was no association between bPFS and use of pelvic ENI in multivariate analysis (HR: 1.10 [95% CI: 0.78-1.55], P=.60), even when analysis was restricted to pN0 patients (HR: 0.88 [95% CI: 0.59-1.31], P=.53). Pelvic ENI was not associated with increased acute or late patient reported toxicity. Conclusions: This unplanned analysis of

  2. Nodal in computerized control systems of accelerators

    International Nuclear Information System (INIS)

    Kagarmanov, A.A.; Koval'tsov, V.I.; Korobov, S.A.

    1994-01-01

    Brief description of the Nodal language programming structure is presented. Its possibilities as high-level programming language for accelerator control systems are considered. The status of the Nodal language in the HEPI is discussed. 3 refs

  3. A variational synthesis nodal discrete ordinates method

    International Nuclear Information System (INIS)

    Favorite, J.A.; Stacey, W.M.

    1999-01-01

    A self-consistent nodal approximation method for computing discrete ordinates neutron flux distributions has been developed from a variational functional for neutron transport theory. The advantage of the new nodal method formulation is that it is self-consistent in its definition of the homogenized nodal parameters, the construction of the global nodal equations, and the reconstruction of the detailed flux distribution. The efficacy of the method is demonstrated by two-dimensional test problems

  4. Chronic pelvic pain.

    Science.gov (United States)

    Stein, Sharon L

    2013-12-01

    Chronic pelvic pain is pain lasting longer than 6 months and is estimated to occur in 15% of women. Causes of pelvic pain include disorders of gynecologic, urologic, gastroenterologic, and musculoskeletal systems. The multidisciplinary nature of chronic pelvic pain may complicate diagnosis and treatment. Treatments vary by cause but may include medicinal, neuroablative, and surgical treatments. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Postirradiation changes in the pelvic wall

    International Nuclear Information System (INIS)

    Soevik, E.; Lien, H.H.; Tveit, K.M.

    1993-01-01

    MR images of 45 patients who had received radiation therapy for carcinoma of the anus or recurrent carcinoma of the rectum were reviewed with regard to postirradiation changes of the pelvic wall. High signal intensity in bone marrow on T1-weighted images due to fatty replacement was almost always observed. Presacral edema occurred in 7 of 36 patients who were examined 4 to 6 weeks after the end of irradiation and was more frequent at later studies. The pelvic wall muscles showed high signal intensity on T2-weighted images compatible with edema. This finding was most frequent on studies performed more than 6 weeks after the end of irradiation. The changes subsided more than a year after radiation therapy. To avoid an erroneous diagnosis of tumor infiltration into the pelvic wall, it is important to be familiar with the normal postirradiation changes of the presacral space and the muscles. (orig.)

  6. NESTLE: A nodal kinetics code

    International Nuclear Information System (INIS)

    Al-Chalabi, R.M.; Turinsky, P.J.; Faure, F.-X.; Sarsour, H.N.; Engrand, P.R.

    1993-01-01

    The NESTLE nodal kinetics code has been developed for utilization as a stand-alone code for steady-state and transient reactor neutronic analysis and for incorporation into system transient codes, such as TRAC and RELAP. The latter is desirable to increase the simulation fidelity over that obtained from currently employed zero- and one-dimensional neutronic models and now feasible due to advances in computer performance and efficiency of nodal methods. As a stand-alone code, requirements are that it operate on a range of computing platforms from memory-limited personal computers (PCs) to supercomputers with vector processors. This paper summarizes the features of NESTLE that reflect the utilization and requirements just noted

  7. Nodal lymphomas of the abdomen

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Caramella, E.; Manzino, J.J.

    1986-01-01

    Modern imaging modalities have greatly contributed to current knowledge about intra-abdominal nodal lymphomas. Since both intra and retroperitoneal node involvement can be demonstrated by computed tomography (CT) and ultrasonography, it seems legitimate to treat these two sites together in the same chapter, particularly since the older separation between intraperitoneal and retroperitoneal nodal disease was based to a large degree on the limitations of lymphography. Hodgkin's disease (HD) has benefited less from recent technological advances. The diversity in the incidence of nodal involvement between HD and NHL, the diagnostic capabilities of modern imaging techniques, and the histopathological features of lymphomatous non-Hodgkin and Hodgkin nodes, justify adoption of an investigatory approach which takes all of these factors into account. Details of this investigative strategy are discussed in this paper following a review of available imaging modalities. In current practice, the four main methods for the exploration of abdominal lymph nodes are lymphography, ultrasonography, CT, and radionuclide studies. The first three techniques are also utilized to guide biopsies for staging purposes and for the evaluation of response to treatment

  8. Different rectal toxicity tolerance with and without simultaneous conventionally-fractionated pelvic lymph node treatment in patients receiving hypofractionated prostate radiotherapy

    International Nuclear Information System (INIS)

    McDonald, Andrew M; Baker, Christopher B; Popple, Richard A; Shekar, Kiran; Yang, Eddy S; Jacob, Rojymon; Cardan, Rex; Kim, Robert Y; Fiveash, John B

    2014-01-01

    To investigate added morbidity associated with the addition of pelvic elective nodal irradiation (ENI) to hypofractionated radiotherapy to the prostate. Two-hundred twelve patients, treated with hypofractionated radiotherapy to the prostate between 2004 and 2011, met the inclusion criteria for the analysis. All patients received 70 Gy to the prostate delivered over 28 fractions and 103 (49%) received ENI consisting of 50.4 Gy to the pelvic lymphatics delivered simultaneously in 1.8 Gy fractions. The mean dose-volume histograms were compared between the two subgroups defined by use of ENI, and various dose-volume parameters were analyzed for effect on late lower gastrointestinal (GI) and genitourinary (GU) toxicity. Acute grade 2 lower GI toxicity occurred in 38 (37%) patients receiving ENI versus 19 (17%) in those who did not (p = 0.001). The Kaplan-Meier estimate of grade ≥ 2 lower GI toxicity at 3 years was 15.3% for patients receiving ENI versus 5.3% for those who did not (p = 0.026). Each rectal isodose volume was increased for patients receiving ENI up to 50 Gy (p ≤ 0.021 for each 5 Gy increment). Across all patients, the absolute V 70 of the rectum was the only predictor of late GI toxicity. When subgroups, defined by the use of ENI, were analyzed separately, rectal V 70 was only predictive of late GI toxicity for patients who received ENI. For patients receiving ENI, V 70 > 3 cc was associated with an increased risk of late GI events. Elective nodal irradiation increases the rates of acute and late GI toxicity when delivered simultaneously with hypofractioanted prostate radiotherapy. The use of ENI appears to sensitize the rectum to hot spots, therefore we recommend added caution to minimize the volume of rectum receiving 100% of the prescription dose in these patients

  9. Different rectal toxicity tolerance with and without simultaneous conventionally-fractionated pelvic lymph node treatment in patients receiving hypofractionated prostate radiotherapy.

    Science.gov (United States)

    McDonald, Andrew M; Baker, Christopher B; Popple, Richard A; Shekar, Kiran; Yang, Eddy S; Jacob, Rojymon; Cardan, Rex; Kim, Robert Y; Fiveash, John B

    2014-06-03

    To investigate added morbidity associated with the addition of pelvic elective nodal irradiation (ENI) to hypofractionated radiotherapy to the prostate. Two-hundred twelve patients, treated with hypofractionated radiotherapy to the prostate between 2004 and 2011, met the inclusion criteria for the analysis. All patients received 70 Gy to the prostate delivered over 28 fractions and 103 (49%) received ENI consisting of 50.4 Gy to the pelvic lymphatics delivered simultaneously in 1.8 Gy fractions. The mean dose-volume histograms were compared between the two subgroups defined by use of ENI, and various dose-volume parameters were analyzed for effect on late lower gastrointestinal (GI) and genitourinary (GU) toxicity. Acute grade 2 lower GI toxicity occurred in 38 (37%) patients receiving ENI versus 19 (17%) in those who did not (p = 0.001). The Kaplan-Meier estimate of grade ≥ 2 lower GI toxicity at 3 years was 15.3% for patients receiving ENI versus 5.3% for those who did not (p = 0.026). Each rectal isodose volume was increased for patients receiving ENI up to 50 Gy (p ≤ 0.021 for each 5 Gy increment). Across all patients, the absolute V70 of the rectum was the only predictor of late GI toxicity. When subgroups, defined by the use of ENI, were analyzed separately, rectal V70 was only predictive of late GI toxicity for patients who received ENI. For patients receiving ENI, V70 > 3 cc was associated with an increased risk of late GI events. Elective nodal irradiation increases the rates of acute and late GI toxicity when delivered simultaneously with hypofractioanted prostate radiotherapy. The use of ENI appears to sensitize the rectum to hot spots, therefore we recommend added caution to minimize the volume of rectum receiving 100% of the prescription dose in these patients.

  10. Development of nodal interface conditions for a PN approximation nodal model

    International Nuclear Information System (INIS)

    Feiz, M.

    1993-01-01

    A relation was developed for approximating higher order odd-moments from lower order odd-moments at the nodal interfaces of a Legendre polynomial nodal model. Two sample problems were tested using different order P N expansions in adjacent nodes. The developed relation proved to be adequate and matched the nodal interface flux accurately. The development allows the use of different order expansions in adjacent nodes, and will be used in a hybrid diffusion-transport nodal model. (author)

  11. Pelvic and acetabular fractures

    International Nuclear Information System (INIS)

    Mears, D.C.; Rubash, H.E.

    1986-01-01

    This treatise focuses primarily on the clinical aspects of diagnosis and treatments of pelvic and acetabular fractures. However, considerable attention is also paid to the radiographic diagnosis of trauma and postoperative effects. The book begins with a succinct review of pelvic and acetabular anatomy and pelvic biomechanics. It continues with a radiographic classification of pelvic injury, which will represent the major source of the book's interest for radiologists. The remainder of the book is concerned with clinical management of pelvic and acetabular trauma, including preoperative planning, surgical approaches, techniques of reduction, internal fixation, eternal fixation, post-operative care, and late problems. Even throughout this later portion of the book there are extensive illustrations, including plain radiographs, computed tomographic (CT) scans, reconstructed three-dimensional CT scans, and schematic diagrams of diverse pelvic and acetabular fractures and the elementary surgical techniques for their repair

  12. Baseline demographic profile and general health influencing the post-radiotherapy health related quality-of-life in women with gynaecological malignancy treated with pelvic irradiation

    Directory of Open Access Journals (Sweden)

    Sourav Sau

    2013-01-01

    Full Text Available Background: Cancer specific survival and quality-of-life (QOL assessment are important in evaluating cancer treatment outcomes. Baseline demographic profiles have significant effects on follow-up health related QOL (HRQOL and affect the outcome of treatments. Materials and Methods: Post-operative gynaecological cancer patients required adjuvant pelvic radiation enrolled longitudinal assessment study. Patients had completed the short form-36 (SF-36 questionnaire before the adjuvant radiotherapy and functional assessments of cancer therapy-general module at 6 th month′s follow-up period to assess the HRQOL. Baseline variables were race, age, body mass index (BMI, education, marital status, type of surgery, physical composite scores (PCS and mental composite scores (MCS summary scores of the SF-36. Univariate and multivariate regression analysis used to determine the influence of these variables on post-radiotherapy HRQOL domains. Results: Baseline PCS, MCS, age, education and marital status had positively correlation with post-radiotherapy HRQOL while higher BMI had a negative impact in univariate analysis. In multivariate regression analysis, education and MCS had a positive correlation while higher BMI had a negative correlation with HRQOL domains. Conclusion: Enhance our ability to detect demographic variables and modify those factors and develops new treatment aimed at improving all aspect of gynaecological cancer including good QOL.

  13. CT simulation in nodal positive breast cancer

    International Nuclear Information System (INIS)

    Horst, E.; Schuck, A.; Moustakis, C.; Schaefer, U.; Micke, O.; Kronholz, H.L.; Willich, N.

    2001-01-01

    Background: A variety of solutions are used to match tangential fields and opposed lymph node fields in irradiation of nodal positive breast cancer. The choice is depending on the technical equipment which is available and the clinical situation. The CT simulation of a non-monoisocentric technique was evaluated in terms of accuracy and reproducibility. Patients, Material and Methods: The field match parameters were adjusted virtually at CT simulation and were compared with parameters derived mathematically. The coordinate transfer from the CT simulator to the conventional simulator was analyzed in 25 consecutive patients. Results: The angles adjusted virtually for a geometrically exact coplanar field match corresponded with the angles calculated for each set-up. The mean isocenter displacement was 5.7 mm and the total uncertainty of the coordinate transfer was 6.7 mm (1 SD). Limitations in the patient set-up became obvious because of the steep arm abduction necessary to fit the 70 cm CT gantry aperture. Required modifications of the arm position and coordinate transfer errors led to a significant shift of the marked matchline of >1.0 cm in eight of 25 patients (32%). Conclusion: The virtual CT simulation allows a precise and graphic definition of the field match parameters. However, modifications of the virtual set-up basically due to technical limitations were required in a total of 32% of cases, so that a hybrid technique was adapted at present that combines virtual adjustment of the ideal field alignment parameters with conventional simulation. (orig.) [de

  14. Factors influencing bowel sparing in intensity modulated whole pelvic radiotherapy for gynaecological malignancies

    International Nuclear Information System (INIS)

    Georg, Petra; Georg, Dietmar; Hillbrand, Martin; Kirisits, Christian; Poetter, Richard

    2006-01-01

    Background and purpose: To evaluate the influence of uterus and bladder size on large and small bowel sparing with intensity modulated whole pelvic radiotherapy (IM-WPRT) in gynecologic patients. Patients and methods: Twenty patients were selected; 10 women with cervical cancer treated with definitive radiotherapy (group 'DEF') and 10 endometrial cancer patients treated postoperatively (group 'POST'). Bladder, rectal wall, small (SB) and large bowel (LB) were delineated as organs at risk. A conformal four field technique and a seven field IMRT plan (prescription dose 50.4 Gy) were compared in terms of DVH and various target parameters. Results: At doses between 40 and 50.4 Gy statistically significant improvements (P<0.05) were observed for IM-WPRT for irradiated volume of rectal wall and bladder. In both patient groups, with IMRT the average irradiated volume of SB was reduced by a factor of 6 at 50.4 Gy. This ratio was 2 for LB. In the DEF group the effect of SB-sparing with IMRT correlated with bladder size (correlation coefficient 0.70) while it did not correlate in the postoperative group. The effect of LB-sparing decreased with increasing bladder size in both groups but the impact of IMRT was larger for postoperative patients. Conclusions: IMRT significantly reduced the absolute volume of rectal wall, bladder and bowel irradiated at the prescribed dose level in gynaecologic patients. Main differences between POST and DEF patients receiving IM-WPRT were absolute volumes of LB irradiated to doses between 35 and 50 Gy, suggesting an impact of intact uterus on LB volume in the pelvis. POST patients seem to benefit most from elective nodal IMRT. Bladder filling is an important co-factor influencing the benefit of IMRT with respect to OAR sparing

  15. The Nudo, Rollo, Melon codes and nodal correlations

    International Nuclear Information System (INIS)

    Perlado, J.M.; Aragones, J.M.; Minguez, E.; Pena, J.

    1975-01-01

    Analysis of nodal calculation and checking results by the reference reactor experimental data. Nudo code description, adapting experimental data to nodal calculations. Rollo, Melon codes as improvement in the cycle life calculations of albedos, mixing parameters and nodal correlations. (author)

  16. Concomitant pelvic irradiation and chemotherapy in locally advanced cervical carcinoma. A retrospective study of 92 patients treated at the Curie Institute

    International Nuclear Information System (INIS)

    Nguyen, D.; Rochefordiere, A. de la; Chauveinc, L.; Cosset, J.M.; Clough, K.B.; Mouret-Fourme, E.; Guyonnet, M.

    2002-01-01

    The prognosis of locally advanced cervix cancers is poor with metastatic and local recurrence risks. Recent publications reported that concurrent chemotherapy and pelvic radiation increased local control compared to radiotherapy alone. Chemotherapy could also decrease metastatic recurrences. We report 92 cases of patients with locally advanced cervix cancer treated between 1986 and 1998 at the Institut Curie. Patients and methods. - Concurrent chemo-radiation was exclusive in 51 cases and added to surgery in 41 cases. Chemotherapy with 5FU -Cisplatin-Mitomycin C-Vindesin (protocol A) was performed for 43% of patients and 57% of them received 5FU-Cisplatin alone (protocol B). Results. -Median follow-up was 64 months (6-149 months). Five-year disease-free survival rate was 47% and local control rate was 70%. Disease-free survival was correlated with therapeutic response. After exclusive chemo-radiation, the good responsive patients had a better DFS (54% vs 26%, p=0.018). In the surgery group, those patients with sterilized lymph nodes and tumours had also a higher DFS (76% vs 47%, p=0.036). Toxicity was higher with protocol A. Conclusion. - From our study, it appears that local control of advanced cervix cancers is better with combined chemoradiotherapy but disease-free survival stays low according to the metastatic evolution. Metastasis without local recurrence remained frequent in our study. 5FU-CDDP chemotherapy has a lower toxicity and is as effective as 5FU-CDDP-Mitomycin C-Vindesin protocol, in association with radiotherapy. (author)

  17. Heterogeneous treatment in the variational nodal method

    International Nuclear Information System (INIS)

    Fanning, T.H.

    1995-01-01

    The variational nodal transport method is reduced to its diffusion form and generalized for the treatment of heterogeneous nodes while maintaining nodal balances. Adapting variational methods to heterogeneous nodes requires the ability to integrate over a node with discontinuous cross sections. In this work, integrals are evaluated using composite gaussian quadrature rules, which permit accurate integration while minimizing computing time. Allowing structure within a nodal solution scheme avoids some of the necessity of cross section homogenization, and more accurately defines the intra-nodal flux shape. Ideally, any desired heterogeneity can be constructed within the node; but in reality, the finite set of basis functions limits the practical resolution to which fine detail can be defined within the node. Preliminary comparison tests show that the heterogeneous variational nodal method provides satisfactory results even if some improvements are needed for very difficult, configurations

  18. Chronic female pelvic pain

    Directory of Open Access Journals (Sweden)

    Gaurab Maitra

    2013-01-01

    Full Text Available Chronic pelvic pain (CPP is defined as nonmalignant pain perceived in the structures related to the pelvis that has been present for more than 6 months or a non acute pain mechanism of shorter duration. Pain in the pelvic region can arise from musculoskeletal, gynaecological, urologic, gastrointestinal and or neurologic conditions. Key gynaecological conditions that contribute to CPP include pelvic inflammatory disease (PID, endometriosis, adnexa pathologies (ovarian cysts, ovarian remnant syndrome, uterine pathologies (leiomyoma, adenomyosis and pelvic girdle pain associated with pregnancy. Several major and minor sexually transmitted diseases (STD can cause pelvic and vulvar pain. A common painful condition of the urinary system is Interstitial cystitis(IC. A second urologic condition that can lead to development of CPP is urethral syndrome. Irritable bowel syndrome (IBS is associated with dysmenorrhoea in 60% of cases. Other bowel conditions contributing to pelvic pain include diverticular disease,Crohn′s disease ulcerative colitis and chronic appendicitis. Musculoskeletal pathologies that can cause pelvic pain include sacroiliac joint (SIJ dysfunction, symphysis pubis and sacro-coccygeal joint dysfunction, coccyx injury or malposition and neuropathic structures in the lower thoracic, lumbar and sacral plexus. Prolonged pelvic girdle pain, lasting more than 6 months postpartum is estimated in 3% to 30% of women. Nerve irritation or entrapment as a cause of pelvic pain can be related to injury of the upper lumbar segments giving rise to irritation of the sensory nerves to the ventral trunk or from direct trauma from abdominal incisions or retractors used during abdominal surgical procedures. Afflictions of the iliohypogastric, ilioinguinal, genitofemoral, pudendal and obturator nerves are of greatest concern in patients with pelvic pain. Patient education about the disease and treatment involved is paramount. A knowledge of the differential

  19. Atlas-Based Segmentation Improves Consistency and Decreases Time Required for Contouring Postoperative Endometrial Cancer Nodal Volumes

    International Nuclear Information System (INIS)

    Young, Amy V.; Wortham, Angela; Wernick, Iddo; Evans, Andrew; Ennis, Ronald D.

    2011-01-01

    Purpose: Accurate target delineation of the nodal volumes is essential for three-dimensional conformal and intensity-modulated radiotherapy planning for endometrial cancer adjuvant therapy. We hypothesized that atlas-based segmentation ('autocontouring') would lead to time savings and more consistent contours among physicians. Methods and Materials: A reference anatomy atlas was constructed using the data from 15 postoperative endometrial cancer patients by contouring the pelvic nodal clinical target volume on the simulation computed tomography scan according to the Radiation Therapy Oncology Group 0418 trial using commercially available software. On the simulation computed tomography scans from 10 additional endometrial cancer patients, the nodal clinical target volume autocontours were generated. Three radiation oncologists corrected the autocontours and delineated the manual nodal contours under timed conditions while unaware of the other contours. The time difference was determined, and the overlap of the contours was calculated using Dice's coefficient. Results: For all physicians, manual contouring of the pelvic nodal target volumes and editing the autocontours required a mean ± standard deviation of 32 ± 9 vs. 23 ± 7 minutes, respectively (p = .000001), a 26% time savings. For each physician, the time required to delineate the manual contours vs. correcting the autocontours was 30 ± 3 vs. 21 ± 5 min (p = .003), 39 ± 12 vs. 30 ± 5 min (p = .055), and 29 ± 5 vs. 20 ± 5 min (p = .0002). The mean overlap increased from manual contouring (0.77) to correcting the autocontours (0.79; p = .038). Conclusion: The results of our study have shown that autocontouring leads to increased consistency and time savings when contouring the nodal target volumes for adjuvant treatment of endometrial cancer, although the autocontours still required careful editing to ensure that the lymph nodes at risk of recurrence are properly included in the target volume.

  20. Bony landmarks are not an adequate substitute for lymphangiography in defining pelvic lymph node location for the treatment of cervical cancer with radiotherapy

    International Nuclear Information System (INIS)

    Bonin, Steven R.; Lanciano, Rachelle M.; Corn, Benjamin W.; Hogan, W. Michael; Hartz, William H.; Hanks, Gerald E.

    1996-01-01

    cm from the previously described reference line had mean values of 2.0 ± 1.0 cm (range 1.3 to 3.0 cm), 0.9 ± 3.9 cm (range -1.9 to 5.1 cm), and 1.8 ± 2.1 cm (range -0.8 to 3.5 cm), respectively. Ten of 22 (45%) patients would have had inadequate nodal irradiation if their fields had been designed according to standard GOG parameters. In all cases, these incompletely irradiated lymph nodes were from the lowest of the lateral external iliac group. Conclusions: Great variability in pelvic lymph node location is demonstrated when LAG is used to directly visualize their location. Bony structures are inaccurate landmarks for pelvic lymph node position. The GOG standard pelvic fields are not consistently adequate to cover all lateral external iliac lymph nodes, although the clinical significance of this subgroup of lymph nodes is not known. At this time, LAG remains the ideal radiographic modality to define anatomic location of regional lymph nodes for pelvic RT treatment planning. The clinical importance of the most lateral group of external iliac lymph nodes in various stages of cervical cancer represents a potential area of future research

  1. CTCAE v.3.0 in evaluation the radiation adverse events in cancer patients after pelvic irradiation (Contemporary mechanisms of radiation and comprehensive damage after cancer treatment)

    International Nuclear Information System (INIS)

    Encheva, E.; Zahariev, Z.; Sultanov, B.; Hadjieva, T.

    2010-01-01

    The authors present the first report of applying the NCI CTCAE v.3.0 for evaluation of radiation adverse events in Bulgaria. The adverse events are observed in early stage cervical and endometrial cancer patients receiving external beam radiotherapy after radical surgery during the radiotherapy and 3 months after it ended. The paper discusses the contemporary concepts of the normal tissue morbidity, the issue early-late adverse events, comprehensive factors and causes, except irradiation, involved in their occurrence. The possibility to define the single method contribution of the comprehensive cancer treatment for development of post-treatment adverse events in cancer survivors in effort to improve their quality of life is discussed. (authors)

  2. Long-term results of para-aortic irradiation for patients with stage I seminoma of the testis

    International Nuclear Information System (INIS)

    Niazi, Tamim M.; Souhami, Luis; Sultanem, Khalil; Duclos, Marie; Shenouda, George; Freeman, Carolyn

    2005-01-01

    Purpose: Adjuvant postoperative para-aortic lymph nodal irradiation is an acceptable alternative to para-aortic and ipsilateral pelvic irradiation postorchiectomy for patients with Stage I seminoma of the testis. In this article, we report the long-term results of our prospective evaluation of para-aortic irradiation only for such patients. Methods and materials: Between March 1991 and September 2000, 71 patients with Stage I seminoma were treated with adjuvant irradiation to the para-aortic region only after radical inguinal orchiectomy. Radiotherapy was delivered using parallel-opposed fields extending from T11 to L5. A total dose of 25 Gy in 15 fractions was prescribed to midpoint. Follow-up was performed every 3 months for the first year, every 4 months for the second and third years, every 6 months for the fourth and fifth years, and annually thereafter. Chest X-ray, tumor markers, and computed tomography scan of the pelvis were performed routinely as part of the follow-up investigation. Results: At a median follow-up of 75 months, 68 of 71 patients are alive and free of relapse. Only 1 patient (1.4%) experienced failure in the ipsilateral inguinal nodal region. Two patients (2.8%) died of unrelated causes. The actuarial 10-year relapse free survival is 98.5% and the actuarial 10-year overall survival is 92%. No late toxicity has been encountered. Conclusion: Patients with Stage I seminoma of the testis may be safely treated with para-aortic radiotherapy only. Risk of pelvic failure is very low and treatment toxicity minimal

  3. Nodal pricing in a coupled electricity market

    OpenAIRE

    Bjørndal, Endre; Bjørndal, Mette; Cai, Hong

    2014-01-01

    This paper investigates a pricing model for an electricity market with a hybrid congestion management method, i.e. part of the system applies a nodal pricing scheme and the rest applies a zonal pricing scheme. The model clears the zonal and nodal pricing areas simultaneously. The nodal pricing area is affected by the changes in the zonal pricing area since it is directly connected to the zonal pricing area by commercial trading. The model is tested on a 13-node power system. Within the area t...

  4. A comparison of two nodal codes : Advanced nodal code (ANC) and analytic function expansion nodal (AFEN) code

    International Nuclear Information System (INIS)

    Chung, S.K.; Hah, C.J.; Lee, H.C.; Kim, Y.H.; Cho, N.Z.

    1996-01-01

    Modern nodal methods usually employs the transverse integration technique in order to reduce a multi-dimensional diffusion equation to one-dimensional diffusion equations. The use of the transverse integration technique requires two major approximations such as a transverse leakage approximation and a one-dimensional flux approximation. Both the transverse leakage and the one-dimensional flux are approximated by polynomials. ANC (Advanced Nodal Code) developed by Westinghouse employs a modern nodal expansion method for the flux calculation, the equivalence theory for the homogenization error reduction and a group theory for pin power recovery. Unlike the conventional modern nodal methods, AFEN (Analytic Function Expansion Nodal) method expands homogeneous flux distributions within a node into non-separable analytic basis functions, which eliminate two major approximations of the modern nodal methods. A comparison study of AFEN with ANC has been performed to see the applicability of AFEN to commercial PWR and different types of reactors such as MOX fueled reactor. The qualification comparison results demonstrate that AFEN methodology is accurate enough to apply for commercial PWR analysis. The results show that AFEN provides very accurate results (core multiplication factor and assembly power distribution) for cores that exhibit strong flux gradients as in a MOX loaded core. (author)

  5. Maternal Nodal inversely affects NODAL and STOX1 expression in the fetal placenta

    Directory of Open Access Journals (Sweden)

    Hari Krishna Thulluru

    2013-08-01

    Full Text Available Nodal, a secreted signaling protein from the TGFβ-super family plays a vital role during early embryonic development. Recently, it was found that maternal decidua-specific Nodal knockout mice show intrauterine growth restriction (IUGR and preterm birth. As the chromosomal location of NODAL is in the same linkage area as the susceptibility gene STOX1, associated with the familial form of early-onset, IUGR-complicated pre-eclampsia, their potential maternal-fetal interaction was investigated. Pre-eclamptic mothers with children who carried the STOX1 susceptibility allele themselves all carried the NODAL H165R SNP, which causes a 50% reduced activity. Surprisingly, in decidua Nodal knockout mice the fetal placenta showed up-regulation of STOX1 and NODAL expression. Conditioned media of human first trimester decidua and a human endometrial stromal cell line (T-HESC treated with siRNAs against NODAL or carrying the H165R SNP were also able to induce NODAL and STOX1 expression when added to SGHPL-5 first trimester extravillous trophoblast cells. Finally, a human TGFß-BMP-Signaling-Pathway PCR-Array on decidua and the T-HESC cell line with Nodal knockdown revealed upregulation of Activin-A, which was confirmed in conditioned media by ELISA. We show that maternal decidua Nodal knockdown gives upregulation of NODAL and STOX1 mRNA expression in fetal extravillous trophoblast cells, potentially via upregulation of Activin-A in the maternal decidua. As both Activin-A and Nodal have been implicated in pre-eclampsia, being increased in serum of pre-eclamptic women and upregulated in pre-eclamptic placentas respectively, this interaction at the maternal-fetal interface might play a substantial role in the development of pre-eclampsia.

  6. Continuous infusion (CI) 5-FU and leucovorin (LCV) combined with hepatic (H), nodal (N), and tumor bed (TB) irradiation (XRT) following pancreaticoduodenectomy (PDD) for head of pancreas (HOP) and other periampullary (PA) adenocarcinoma

    International Nuclear Information System (INIS)

    Abrams, R.A.; Yeo, C.J.; Grochow, L.B.; Chakravarthy, A.; Sohn, T.A.; Zahurek, M.L.; Haulk, T.; Ord, S.; Hruban, R.H.; Lillemoe, K.D.; Pitt, H.A.; Cameron, J.L.

    1996-01-01

    median actuarial survival was 17 months (mo) which did not change when the pts with microscopically +ve margins were excluded. When compared to a contemporaneous cohort of 99 PDD pts operated for HOP at our hospital who received std GITSG adj therapy no improvement in median survival was noted (17 mo vs 21 mo respectively). However, median survival was improved in both treated groups as compared to 54 contemporaneous HOP pts who refused adj therapy (median survival 12.5 mo) (p=0.002). At the time of this analysis 23 study pts had failed with first sites of disease progression including Hepatic (11), peritoneal/mesentery (5), or nodal/TB (6). Conclusions: Although this therapy is substantially more complicated to administer than std adj therapy, the toxicities were manageable and nonlimiting. The activity of the therapy was disappointing as judged by a high rate of disease progression on therapy (32%), no evidence of improved survival, and no evidence of altered patterns of disease failure

  7. Quantum oscillations in nodal line systems

    Science.gov (United States)

    Yang, Hui; Moessner, Roderich; Lim, Lih-King

    2018-04-01

    We study signatures of magnetic quantum oscillations in three-dimensional nodal line semimetals at zero temperature. The extended nature of the degenerate bands can result in a Fermi surface geometry with topological genus one, as well as a Fermi surface of electron and hole pockets encapsulating the nodal line. Moreover, the underlying two-band model to describe a nodal line is not unique, in that there are two classes of Hamiltonian with distinct band topology giving rise to the same Fermi-surface geometry. After identifying the extremal cyclotron orbits in various magnetic field directions, we study their concomitant Landau levels and resulting quantum oscillation signatures. By Landau-fan-diagram analyses, we extract the nontrivial π Berry phase signature for extremal orbits linking the nodal line.

  8. Sensitivity of SBLOCA analysis to model nodalization

    International Nuclear Information System (INIS)

    Lee, C.; Ito, T.; Abramson, P.B.

    1983-01-01

    The recent Semiscale test S-UT-8 indicates the possibility for primary liquid to hang up in the steam generators during a SBLOCA, permitting core uncovery prior to loop-seal clearance. In analysis of Small Break Loss of Coolant Accidents with RELAP5, it is found that resultant transient behavior is quite sensitive to the selection of nodalization for the steam generators. Although global parameters such as integrated mass loss, primary inventory and primary pressure are relatively insensitive to the nodalization, it is found that the predicted distribution of inventory around the primary is significantly affected by nodalization. More detailed nodalization predicts that more of the inventory tends to remain in the steam generators, resulting in less inventory in the reactor vessel and therefore causing earlier and more severe core uncovery

  9. Twisted Vector Bundles on Pointed Nodal Curves

    Indian Academy of Sciences (India)

    Abstract. Motivated by the quest for a good compactification of the moduli space of -bundles on a nodal curve we establish a striking relationship between Abramovich's and Vistoli's twisted bundles and Gieseker vector bundles.

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... often used to determine the cause of unexplained pain. CT scanning is fast, painless, noninvasive and accurate. ... help diagnose the cause of abdominal or pelvic pain and diseases of the internal organs, small bowel ...

  11. Chronic Pelvic Pain

    Science.gov (United States)

    ... NSAIDs) are helpful in relieving pelvic pain, especially dysmenorrhea . Physical therapy—Acupuncture, acupressure, and nerve stimulation therapies may be useful in treating pain caused by dysmenorrhea. Physical therapy that eases trigger points may give ...

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... test used to help detect diseases of the small bowel, colon and other internal organs and is ... pelvic pain and diseases of the internal organs, small bowel and colon, such as: infections such as ...

  13. Pelvic Organ Prolapse

    Science.gov (United States)

    ... the Treatment Options for Pelvic Organ Prolapse? After obtaining a detailed medical history and completing a thorough ... Food and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1- ...

  14. Chronic pelvic floor dysfunction.

    Science.gov (United States)

    Hartmann, Dee; Sarton, Julie

    2014-10-01

    The successful treatment of women with vestibulodynia and its associated chronic pelvic floor dysfunctions requires interventions that address a broad field of possible pain contributors. Pelvic floor muscle hypertonicity was implicated in the mid-1990s as a trigger of major chronic vulvar pain. Painful bladder syndrome, irritable bowel syndrome, fibromyalgia, and temporomandibular jaw disorder are known common comorbidities that can cause a host of associated muscular, visceral, bony, and fascial dysfunctions. It appears that normalizing all of those disorders plays a pivotal role in reducing complaints of chronic vulvar pain and sexual dysfunction. Though the studies have yet to prove a specific protocol, physical therapists trained in pelvic dysfunction are reporting success with restoring tissue normalcy and reducing vulvar and sexual pain. A review of pelvic anatomy and common findings are presented along with suggested physical therapy management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Pelvic Inflammatory Disease (PID)

    Science.gov (United States)

    ... types of infections. Bacterial Vaginosis: A type of vaginal infection caused by the overgrowth of a number of ... of the uterus at the top of the vagina. Chlamydia: A sexually transmitted infection caused by bacteria that can lead to pelvic ...

  16. Extraperitoneal pelvic leiomyosarcoma

    International Nuclear Information System (INIS)

    Santamarina, Mario G.; Baltazar, Alberto D.; Arce, Patricia; Dettano, Veronica; Lopez, Jessica

    2003-01-01

    Extraperitoneal pelvic leiomyosarcoma is a very uncommon neoplasic process. It is a highly aggressive tumor with unfavorable prognosis. Clinical findings are nonspecific; diagnosis is generally made in an advanced stage of the disease. We present a case of a 34 years old female patient with pelvic leiomyosarcoma located at the recto vaginal septum who referred vulvar tumor and disability of the left lower limb. This case report describes the results obtained by ultrasound, Computed Tomography, Magnetic Resonance Imaging and pathology. (author)

  17. The NODAL system for the SPS

    International Nuclear Information System (INIS)

    Crowley-Milling, M.C.; Shering, G.C.

    1978-01-01

    A comprehensive description is given of the NODAL system used for computer control of the CERN Super-Proton Synchrotron. Details are given of NODAL, a high-level programming language based on FOCAL and SNOBOL4, designed for interactive use. It is shown how this interpretive language is used with a network of computers and how it can be extended by adding machine-code modules. The report updates and replaces an earlier one published in 1974. (Auth.)

  18. Nodal coupling by response matrix principles

    International Nuclear Information System (INIS)

    Ancona, A.; Becker, M.; Beg, M.D.; Harris, D.R.; Menezes, A.D.; VerPlanck, D.M.; Pilat, E.

    1977-01-01

    The response matrix approach has been used in viewing a reactor node in isolation and in characterizing the node by reflection and trans-emission factors. These are then used to generate invariant imbedding parameters, which in turn are used in a nodal reactor simulator code to compute core power distributions in two and three dimensions. Various nodal techniques are analyzed and converted into a single invariant imbedding formalism

  19. Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Faisal [University of Utah School of Medicine, Salt Lake City, UT (United States); Loma Linda University Medical Center, Department of Radiation Oncology, Loma Linda, CA (United States); Sarkar, Vikren; Gaffney, David K.; Salter, Bill [Department of Radiation Oncology, University of Utah, Salt Lake City, UT (United States); Poppe, Matthew M., E-mail: matthew.poppe@hci.utah.edu [Department of Radiation Oncology, University of Utah, Salt Lake City, UT (United States)

    2016-10-01

    Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipse treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In

  20. Amifostine as radioprotective agent for the rectal mucosa during irradiation of pelvic tumors. A phase II randomized study using various toxicity scales and rectosigmoidoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kouvaris, J.; Antypas, C.; Kokakis, J.; Vlahos, L. [Radiology-Radiotherapy Dept., National Technical Univ. of Athens (Greece); Kouloulias, V. [Radiology-Radiotherapy Dept., National Technical Univ. of Athens (Greece); Dept. of Electrical and Computer Engineering, Inst. of Communication and Computer Systems, National Technical Univ. of Athens (Greece); Malas, E. [Endoscopy-Gastroenterology Unit, Dept. of Surgical Oncology, Aretaieion Univ. Hospital, Athens (Greece); Michopoulos, S. [Dept. of Gastroenterology, Alexandra General Hospital of Athens (Greece); Matsopoulos, G. [Dept. of Electrical and Computer Engineering, Inst. of Communication and Computer Systems, National Technical Univ. of Athens (Greece)

    2003-03-01

    Aim: To evaluate the cytoprotective effect of amifostine against radiation-induced acute toxicity to the rectal mucosa. Patients and Methods: 36 patients irradiated for prostate or gynecologic cancer were randomized to receive amifostine (n = 18, group A) or not (n = 18, group B). The radiation-induced acute rectal toxicity was evaluated by using three different toxicity scales: WHO scale, EORTC/RTOG toxicity criteria, and a modified toxicity scale based on the LENT-SOMA grading scale and the endoscopic terminology of the World Organization for Digestive Endoscopy. The objective measurements were coming from flexible rectosigmoidoscopy performed at baseline and 1-2 days after completion of the radiotherapy schedule. Anterior-posterior fields were used in the gynecologic patients while 3-D conformal 4-field technique was applied in the prostate cancer patients. The area under the curve (AUC) for dose-volume histograms (DVHs) of the rectum was also assessed during a 3-D treatment planning schedule, and no significant differences were assessed between the two groups, indicating a homogeneous dose-volume effect. Results: Amifostine was well tolerated. No grade 2 or higher WHO and EORTC/RTOG acute toxicity was noted in group A, while acute rectal toxicity ({>=} grade 1) was observed in 16/18 patients of group B versus 2/18 of group A (p < 0.001). The onset as well as the duration of acute rectal toxicity were significantly improved in group A (p = 0.002). Rectosigmoidoscopy revealed more severe rectal mucositis in noncytoprotected patients (group B), and modified LENT-SOMA overall mucositis grading score was significantly lower in group A (p = 0.003). Conclusion: Amifostine seems to have a significant cytoprotective efficacy in acute radiation-induced rectal mucositis in terms of symptomatic and objective endpoints. (orig.)

  1. Amifostine as radioprotective agent for the rectal mucosa during irradiation of pelvic tumors. A phase II randomized study using various toxicity scales and rectosigmoidoscopy

    International Nuclear Information System (INIS)

    Kouvaris, J.; Antypas, C.; Kokakis, J.; Vlahos, L.; Kouloulias, V.; Malas, E.; Michopoulos, S.; Matsopoulos, G.

    2003-01-01

    Aim: To evaluate the cytoprotective effect of amifostine against radiation-induced acute toxicity to the rectal mucosa. Patients and Methods: 36 patients irradiated for prostate or gynecologic cancer were randomized to receive amifostine (n = 18, group A) or not (n = 18, group B). The radiation-induced acute rectal toxicity was evaluated by using three different toxicity scales: WHO scale, EORTC/RTOG toxicity criteria, and a modified toxicity scale based on the LENT-SOMA grading scale and the endoscopic terminology of the World Organization for Digestive Endoscopy. The objective measurements were coming from flexible rectosigmoidoscopy performed at baseline and 1-2 days after completion of the radiotherapy schedule. Anterior-posterior fields were used in the gynecologic patients while 3-D conformal 4-field technique was applied in the prostate cancer patients. The area under the curve (AUC) for dose-volume histograms (DVHs) of the rectum was also assessed during a 3-D treatment planning schedule, and no significant differences were assessed between the two groups, indicating a homogeneous dose-volume effect. Results: Amifostine was well tolerated. No grade 2 or higher WHO and EORTC/RTOG acute toxicity was noted in group A, while acute rectal toxicity (≥ grade 1) was observed in 16/18 patients of group B versus 2/18 of group A (p < 0.001). The onset as well as the duration of acute rectal toxicity were significantly improved in group A (p = 0.002). Rectosigmoidoscopy revealed more severe rectal mucositis in noncytoprotected patients (group B), and modified LENT-SOMA overall mucositis grading score was significantly lower in group A (p = 0.003). Conclusion: Amifostine seems to have a significant cytoprotective efficacy in acute radiation-induced rectal mucositis in terms of symptomatic and objective endpoints. (orig.)

  2. Anorectal and Pelvic Pain.

    Science.gov (United States)

    Bharucha, Adil E; Lee, Tae Hee

    2016-10-01

    Although pelvic pain is a symptom of several structural anorectal and pelvic disorders (eg, anal fissure, endometriosis, and pelvic inflammatory disease), this comprehensive review will focus on the 3 most common nonstructural, or functional, disorders associated with pelvic pain: functional anorectal pain (ie, levator ani syndrome, unspecified anorectal pain, and proctalgia fugax), interstitial cystitis/bladder pain syndrome, and chronic prostatitis/chronic pelvic pain syndrome. The first 2 conditions occur in both sexes, while the latter occurs only in men. They are defined by symptoms, supplemented with levator tenderness (levator ani syndrome) and bladder mucosal inflammation (interstitial cystitis). Although distinct, these conditions share several similarities, including associations with dysfunctional voiding or defecation, comorbid conditions (eg, fibromyalgia, depression), impaired quality of life, and increased health care utilization. Several factors, including pelvic floor muscle tension, peripheral inflammation, peripheral and central sensitization, and psychosocial factors, have been implicated in the pathogenesis. The management is tailored to symptoms, is partly supported by clinical trials, and includes multidisciplinary approaches such as lifestyle modifications and pharmacological, behavioral, and physical therapy. Opioids should be avoided, and surgical treatment has a limited role, primarily in refractory interstitial cystitis. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  3. Magnonic triply-degenerate nodal points

    Science.gov (United States)

    Owerre, S. A.

    2017-12-01

    We generalize the concept of triply-degenerate nodal points to non-collinear antiferromagnets. Here, we introduce this concept to insulating quantum antiferromagnets on the decorated honeycomb lattice, with spin-1 bosonic quasiparticle excitations known as magnons. We demonstrate the existence of magnonic surface states with constant energy contours that form pairs of magnonic arcs connecting the surface projection of the magnonic triple nodal points. The quasiparticle excitations near the triple nodal points represent three-component bosons beyond that of magnonic Dirac, Weyl, and nodal-line cases. They can be regarded as a direct reflection of the intrinsic spin carried by magnons. Furthermore, we show that the magnonic triple nodal points can split into magnonic Weyl points, as the system transits from a non-collinear spin structure to a non-coplanar one with a non-zero scalar spin chirality. Our results not only apply to insulating antiferromagnets, but also provide a platform to seek for triple nodal points in metallic antiferromagnets.

  4. Pelvic insufficiency fractures associated with radiation atrophy: clinical recognition and diagnostic evaluation

    International Nuclear Information System (INIS)

    Mumber, M.P.; Greven, K.M.; Haygood, T.M.

    1997-01-01

    Pelvic bone injuries are infrequent complications of radiotherapy. However, insufficiency fractures in irradiated pelvic bones may be underdetected, particularly in postmenopausal women. We describe the clinical presentation, radiologic evaluation, and course of disease in three patients with postradiation pelvic insufficiency fractures. Differential diagnosis included metastatic disease, tumor recurrence, and second malignancy. Recognition of radiographic features may prevent unnecessary, possibly morbid treatments. (orig.). With 6 figs

  5. Primary mesenteric extraskeletal osteosarcoma in the pelvic cavity

    International Nuclear Information System (INIS)

    Choudur, H.N.; Munk, P.L.; Ryan, A.G.M.J.; Nielson, T.O.

    2005-01-01

    A middle-aged man was being investigated for constipation. Abdominal radiographs incidentally revealed a large, densely calcified, rounded mass within the pelvic cavity. A CT scan was performed followed by surgical excision with a differential diagnosis of calcified hematoma and an enlarged calcified lymph nodal mass. Histopathological investigation revealed a primary mesenteric extraskeletal osteosarcoma. To the best of our knowledge, a primary extraskeletal osteosarcoma arising from the mesentery has not been described previously in the English literature. The radiological features and differential diagnosis are discussed. (orig.)

  6. Primary mesenteric extraskeletal osteosarcoma in the pelvic cavity

    Energy Technology Data Exchange (ETDEWEB)

    Choudur, H.N.; Munk, P.L.; Ryan, A.G.M.J. [Vancouver General Hospital, Department of Radiology, Vancouver, BC (Canada); Nielson, T.O. [Vancouver General Hospital, Department of Pathology, Vancouver, BC (Canada)

    2005-10-01

    A middle-aged man was being investigated for constipation. Abdominal radiographs incidentally revealed a large, densely calcified, rounded mass within the pelvic cavity. A CT scan was performed followed by surgical excision with a differential diagnosis of calcified hematoma and an enlarged calcified lymph nodal mass. Histopathological investigation revealed a primary mesenteric extraskeletal osteosarcoma. To the best of our knowledge, a primary extraskeletal osteosarcoma arising from the mesentery has not been described previously in the English literature. The radiological features and differential diagnosis are discussed. (orig.)

  7. Ovarian irradiation in recurrent endometriosis

    International Nuclear Information System (INIS)

    Kochbati, L.; Chaari, N.; Besbes, M.; Maalej, M.; Neji, K.; Ben Amara, F.; Ben Romdhane, N.K.

    2005-01-01

    We describe a case of a young woman with a history of an aplastic anaemia in which pelvic radiotherapy was used successfully in the management of a recurrent and inoperable endometriosis. The use of therapeutic pelvic or ovarian irradiation in endometriosis may be considered, when surgical and medical treatments have been exhausted and have failed. (authors)

  8. Pelvic Insufficiency Fracture After Pelvic Radiotherapy for Cervical Cancer: Analysis of Risk Factors

    International Nuclear Information System (INIS)

    Oh, Dongryul; Huh, Seung Jae; Nam, Heerim; Park, Won; Han, Youngyih; Lim, Do Hoon; Ahn, Yong Chan; Lee, Jeong Won; Kim, Byoung Gie; Bae, Duk Soo; Lee, Je Ho

    2008-01-01

    Purpose: To investigate the incidence, clinical characteristics, and risk factors of pelvic insufficiency fracture (PIF) after pelvic radiotherapy (RT) in cervical cancer. Methods and Materials: Medical records and imaging studies, including bone scintigraphy, CT, and MRI of 557 patients with cervical cancer who received whole-pelvic RT between January 1998 and August 2005 were reviewed. Results: Eighty-three patients were diagnosed as having PIF after pelvic RT. The 5-year cumulative incidence of PIF was 19.7%. The most commonly involved site was the sacroiliac joint. Pelvic pain developed in 48 patients (57.8%) at diagnosis. Eleven patients (13.3%) needed admission or narcotics because of severe pain, and others had good relief of symptoms with conservative management. In univariate analysis, age ≥55 years (p < 0.001), anteroposterior/posteroanterior parallel opposing technique (p = 0.001), curative treatment (p < 0.001), and radiation dose ≥50.4 Gy (p = 0.005) were the predisposing factors for development of PIF. Concurrent chemotherapy (p = 0.78) was not significant. Multivariate analysis showed that age ≥55 years (p < 0.001), body weight <55 kg (p = 0.02), curative treatment (p = 0.03), and radiation dose ≥50.4 Gy (p = 0.04) were significant predisposing factors for development of PIF. Conclusion: The development of PIF is not rare after pelvic RT. The use of multibeam arrangements to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture, especially in elderly women with low body weight

  9. Dosimetric Study of Pelvic Proton Radiotherapy for High-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    Chera, Bhishamjit S.; Vargas, Carlos; Morris, Christopher G.; Louis, Debbie; Flampouri, Stella; Yeung, Daniel; Duvvuri, Srividya; Li Zuofeng; Mendenhall, Nancy Price

    2009-01-01

    Purpose: To compare dose distributions in targeted tissues (prostate, seminal vesicles, pelvic regional nodes) and nontargeted tissues in the pelvis with intensity-modulated radiotherapy (IMRT) and forward-planned, double-scattered, three-dimensional proton radiotherapy (3D-PRT). Methods and Materials: IMRT, IMRT followed by a prostate 3D-PRT boost (IMRT/3D-PRT), and 3D-PRT plans were created for 5 high-risk prostate cancer patients (n = 15 plans). A 78-CGE/Gy dose was prescribed to the prostate and proximal seminal vesicles and a 46-CGE/Gy was prescribed to the pelvic nodes. Various dosimetric endpoints were compared. Results: Target coverage of the prostate and nodal planning target volumes was adequate for all three plans. Compared with the IMRT and IMRT/3D-PRT plans, the 3D-PRT plans reduced the mean dose to the rectum, rectal wall, bladder, bladder wall, small bowel, and pelvis. The relative benefit of 3D-PRT (vs IMRT) at reducing the rectum and rectal wall V5-V40 was 53% to 71% (p < 0.05). For the bladder and bladder wall, the relative benefit for V5 to V40 CGE/Gy was 40% to 63% (p < 0.05). The relative benefit for reducing the volume of small bowel irradiated from 5 to 30 CGE/Gy in the 3D-PRT ranged from 62% to 69% (p < 0.05). Use of 3D-PRT did not produce the typical low-dose 'bath' of radiation to the pelvis seen with IMRT. Femoral head doses were higher for the 3D-PRT. Conclusions: Use of 3D-PRT significantly reduced the dose to normal tissues in the pelvis while maintaining adequate target coverage compared with IMRT or IMRT/3D-PRT. When treating the prostate, seminal vesicles, and pelvic lymph nodes in prostate cancer, proton therapy may improve the therapeutic ratio beyond what is possible with IMRT.

  10. Pelvic floor muscle function in women with pelvic floor dysfunction

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Dehlendorff, Christian

    2014-01-01

    The objectives of this study were to investigate the level of pelvic floor muscle (PFM) function in women with pelvic floor dysfunction (PFD) referred by gynaecologists and urologists for in-hospital pelvic floor muscle training (PFMT), and to identity associated factors for a low level of PFM...

  11. The analytic nodal method in cylindrical geometry

    International Nuclear Information System (INIS)

    Prinsloo, Rian H.; Tomasevic, Djordje I.

    2008-01-01

    Nodal diffusion methods have been used extensively in nuclear reactor calculations, specifically for their performance advantage, but also for their superior accuracy. More specifically, the Analytic Nodal Method (ANM), utilising the transverse integration principle, has been applied to numerous reactor problems with much success. In this work, a nodal diffusion method is developed for cylindrical geometry. Application of this method to three-dimensional (3D) cylindrical geometry has never been satisfactorily addressed and we propose a solution which entails the use of conformal mapping. A set of 1D-equations with an adjusted, geometrically dependent, inhomogeneous source, is obtained. This work describes the development of the method and associated test code, as well as its application to realistic reactor problems. Numerical results are given for the PBMR-400 MW benchmark problem, as well as for a 'cylindrisized' version of the well-known 3D LWR IAEA benchmark. Results highlight the improved accuracy and performance over finite-difference core solutions and investigate the applicability of nodal methods to 3D PBMR type problems. Results indicate that cylindrical nodal methods definitely have a place within PBMR applications, yielding performance advantage factors of 10 and 20 for 2D and 3D calculations, respectively, and advantage factors of the order of 1000 in the case of the LWR problem

  12. Encapsulation of nodal segments of lobelia chinensis

    Directory of Open Access Journals (Sweden)

    Weng Hing Thong

    2015-04-01

    Full Text Available Lobelia chinensis served as an important herb in traditional chinese medicine. It is rare in the field and infected by some pathogens. Therefore, encapsulation of axillary buds has been developed for in vitro propagation of L. chinensis. Nodal explants of L. chinensis were used as inclusion materials for encapsulation. Various combinations of calcium chloride and sodium alginate were tested. Encapsulation beads produced by mixing 50 mM calcium chloride and 3.5% sodium alginate supported the optimal in vitro conversion potential. The number of multiple shoots formed by encapsulated nodal segments was not significantly different from the average of shoots produced by non-encapsulated nodal segments. The encapsulated nodal segments regenerated in vitro on different medium. The optimal germination and regeneration medium was Murashige-Skoog medium. Plantlets regenerated from the encapsulated nodal segments were hardened, acclimatized and established well in the field, showing similar morphology with parent plants. This encapsulation technology would serve as an alternative in vitro regeneration system for L. chinensis.

  13. Retroperitoneal and pelvic fibromatosis

    International Nuclear Information System (INIS)

    Lopez de Lacalle, J. M.; Garmendia, G.; Laso, C.; Galardi, A.

    1998-01-01

    We present a case of retroperitoneal and pelvic fibromatosis in a 17-year-old boy who came to the emergency room with sudden onset acute abdominal pain. The initial radiological examination (plain X-ray and ultrasound) disclosed only minimal right hydronephrosis. Subsequent computed tomography revealed the presence of a solid retroperitoneal and pelvic mass involving right ureter and secondary right hydronephrosis. We stress its presentation in the form of acute abdominal pain with initial radiological signs suggestive of a primarily urological disorder. (Author) 8 refs

  14. Complex models of nodal nuclear data

    International Nuclear Information System (INIS)

    Dufek, Jan

    2011-01-01

    During the core simulations, nuclear data are required at various nodal thermal-hydraulic and fuel burnup conditions. The nodal data are also partially affected by thermal-hydraulic and fuel burnup conditions in surrounding nodes as these change the neutron energy spectrum in the node. Therefore, the nodal data are functions of many parameters (state variables), and the more state variables are considered by the nodal data models the more accurate and flexible the models get. The existing table and polynomial regression models, however, cannot reflect the data dependences on many state variables. As for the table models, the number of mesh points (and necessary lattice calculations) grows exponentially with the number of variables. As for the polynomial regression models, the number of possible multivariate polynomials exceeds the limits of existing selection algorithms that should identify a few dozens of the most important polynomials. Also, the standard scheme of lattice calculations is not convenient for modelling the data dependences on various burnup conditions since it performs only a single or few burnup calculations at fixed nominal conditions. We suggest a new efficient algorithm for selecting the most important multivariate polynomials for the polynomial regression models so that dependences on many state variables can be considered. We also present a new scheme for lattice calculations where a large number of burnup histories are accomplished at varied nodal conditions. The number of lattice calculations being performed and the number of polynomials being analysed are controlled and minimised while building the nodal data models of a required accuracy. (author)

  15. Nodal Structure of the Electronic Wigner Function

    DEFF Research Database (Denmark)

    Schmider, Hartmut; Dahl, Jens Peder

    1996-01-01

    On the example of several atomic and small molecular systems, the regular behavior of nodal patterns in the electronic one-particle reduced Wigner function is demonstrated. An expression found earlier relates the nodal pattern solely to the dot-product of the position and the momentum vector......, if both arguments are large. An argument analogous to the ``bond-oscillatory principle'' for momentum densities links the nuclear framework in a molecule to an additional oscillatory term in momenta parallel to bonds. It is shown that these are visible in the Wigner function in terms of characteristic...

  16. Haemodynamically Unstable Pelvic Fractures

    Science.gov (United States)

    2009-01-01

    through the pubic symphysis, and posteriorlywith the sacrum forming the sacroiliac (SI) joints (Fig. 1). The SI joints are the strongest in the body...Gardner MJ, Kendoff D, Ostermeier S, et al. Sacroiliac joint compression using an anterior pelvic compressor: a mechanical study in synthetic bone. J

  17. Chronic pelvic pain

    African Journals Online (AJOL)

    misdiagnoses, inappropriate or inadequate treatment strategies, and poor patient compliance .... excitation tenderness implies an active pelvic inflammatory process. Pain localising to ... neoplastic process, particularly cervical cancer, must be excluded. .... The dosage should be started at 10 mg at night, and increased by 5 ...

  18. Pelvic Inflammatory Disease (PID)

    Science.gov (United States)

    ... a serious condition, in women. 1 in 8 women with a history of PID experience difficulties getting pregnant. You can prevent PID if you know how to protect yourself. What is PID? Pelvic inflammatory disease is an infection of a woman’s reproductive organs. It is a complication often caused ...

  19. Bilateral femoral neck fractures following pelvic irradiation

    International Nuclear Information System (INIS)

    Mitsuda, Kenji; Nishi, Hosei; Oba, Hiroshi

    1977-01-01

    Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was found out, but thickness of the internal membrane and thrombogenesis were not recognized. Treatment should be performed according to degree of displacement of fractures. In this case, artificial joint replacement surgery was performed to the side of fracture of this time, because this case was bilateral femoral neck fractures and the patient had received artificial head replacement surgery in the other side of fracture formerly. (Tsunoda, M.)

  20. Isospectral graphs with identical nodal counts

    International Nuclear Information System (INIS)

    Oren, Idan; Band, Ram

    2012-01-01

    According to a recent conjecture, isospectral objects have different nodal count sequences (Gnutzmann et al 2005 J. Phys. A: Math. Gen. 38 8921–33). We study generalized Laplacians on discrete graphs, and use them to construct the first non-trivial counterexamples to this conjecture. In addition, these examples demonstrate a surprising connection between isospectral discrete and quantum graphs. (paper)

  1. Comparison of neutronic transport equation resolution nodal methods

    International Nuclear Information System (INIS)

    Zamonsky, O.M.; Gho, C.J.

    1990-01-01

    In this work, some transport equation resolution nodal methods are comparatively studied: the constant-constant (CC), linear-nodal (LN) and the constant-quadratic (CQ). A nodal scheme equivalent to finite differences has been used for its programming, permitting its inclusion in existing codes. Some bidimensional problems have been solved, showing that linear-nodal (LN) are, in general, obtained with accuracy in CPU shorter times. (Author) [es

  2. Pattern of Progression after Stereotactic Body Radiotherapy for Oligometastatic Prostate Cancer Nodal Recurrences.

    Science.gov (United States)

    Ost, P; Jereczek-Fossa, B A; Van As, N; Zilli, T; Tree, A; Henderson, D; Orecchia, R; Casamassima, F; Surgo, A; Miralbell, R; De Meerleer, G

    2016-09-01

    To report the relapse pattern of stereotactic body radiotherapy (SBRT) for oligorecurrent nodal prostate cancer (PCa). PCa patients with ≤3 lymph nodes (N1/M1a) at the time of recurrence were treated with SBRT. SBRT was defined as a radiotherapy dose of at least 5 Gy per fraction to a biological effective dose of at least 80 Gy to all metastatic sites. Distant progression-free survival was defined as the time interval between the first day of SBRT and appearance of new metastatic lesions, outside the high-dose region. Relapses after SBRT were recorded and compared with the initially treated site. Secondary end points were local control, time to palliative androgen deprivation therapy and toxicity scored using the Common Terminology Criteria for Adverse Events v4.0. Overall, 89 metastases were treated in 72 patients. The median distant progression-free survival was 21 months (95% confidence interval 16-25 months) with 88% of patients having ≤3 metastases at the time of progression. The median time from first SBRT to the start of palliative androgen deprivation therapy was 44 months (95% confidence interval 17-70 months). Most relapses (68%) occurred in nodal regions. Relapses after pelvic nodal SBRT (n = 36) were located in the pelvis (n = 14), retroperitoneum (n = 1), pelvis and retroperitoneum (n = 8) or in non-nodal regions (n = 13). Relapses after SBRT for extrapelvic nodes (n = 5) were located in the pelvis (n = 1) or the pelvis and retroperitoneum (n = 4). Late grade 1 and 2 toxicity was observed in 17% (n = 12) and 4% of patients (n = 3). SBRT for oligometastatic PCa nodal recurrences is safe. Most subsequent relapses are again nodal and oligometastatic. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  3. Pelvic radiation disease: Updates on treatment options

    Science.gov (United States)

    Frazzoni, Leonardo; La Marca, Marina; Guido, Alessandra; Morganti, Alessio Giuseppe; Bazzoli, Franco; Fuccio, Lorenzo

    2015-01-01

    Pelvic cancers are among the most frequently diagnosed neoplasms and radiotherapy represents one of the main treatment options. The irradiation field usually encompasses healthy intestinal tissue, especially of distal large bowel, thus inducing gastrointestinal (GI) radiation-induced toxicity. Indeed, up to half of radiation-treated patients say that their quality of life is affected by GI symptoms (e.g., rectal bleeding, diarrhoea). The constellation of GI symptoms - from transient to long-term, from mild to very severe - experienced by patients who underwent radiation treatment for a pelvic tumor have been comprised in the definition of pelvic radiation disease (PRD). A correct and evidence-based therapeutic approach of patients experiencing GI radiation-induced toxicity is mandatory. Therapeutic non-surgical strategies for PRD can be summarized in two broad categories, i.e., medical and endoscopic. Of note, most of the studies have investigated the management of radiation-induced rectal bleeding. Patients with clinically significant bleeding (i.e., causing chronic anemia) should firstly be considered for medical management (i.e., sucralfate enemas, metronidazole and hyperbaric oxygen); in case of failure, endoscopic treatment should be implemented. This latter should be considered the first choice in case of acute, transfusion requiring, bleeding. More well-performed, high quality studies should be performed, especially the role of medical treatments should be better investigated as well as the comparative studies between endoscopic and hyperbaric oxygen treatments. PMID:26677440

  4. Management of pelvic chondrosarcoma

    Directory of Open Access Journals (Sweden)

    Florin Groșeanu

    2016-11-01

    Full Text Available The partial or complete excision of the hemipelvis with sparing of the lower limb is an option of the treatment of pelvic chondrosarcoma and a therapeutic alternative of the interilio-abdominal disarticulation. The operation has in principle the same indications as the interilio-abdominal disarticulation and offers a good solution for avoiding a mutilating operation. The 149 cases include: 120 biopsies, 29 excisional biopsies, 6 interilioabdominal disarticulations and 14 resections – reconstruction’s, one of with prosthetic reconstruction. The prognostic score was established by assessing: the surgical stage, the site of the tumor, the surgical margins of the tumor, the functional mobility and the postoperative activity. The wide excision of the tumor, a stable reconstruction and an efficient recovery are essential for a successful treatment of pelvic chondrosarcoma. The limb sparing resection-reconstruction represents a highly surgical demanding procedure, followed up by complications in 60% of the cases, so that should be performed only by high skilled surgeons. Hemipelvectomy still remains a well-established life-saving surgery method for patients suffering from vast oncological extensions, where a pelvic resection is not an option.

  5. Pathology of nodal marginal zone lymphomas.

    Science.gov (United States)

    Pileri, Stefano; Ponzoni, Maurilio

    Nodal marginal zone B cell lymphomas (NMZLs) are a rare group of lymphoid disorders part of the spectrum of marginal zone B-cell lymphomas, which encompass splenic marginal one B-cell lymphoma (SMZL) and extra nodal marginal zone of B-cell lymphoma (EMZL), often of MALT-type. Two clinicopathological forms of NMZL are recognized: adult-type and pediatric-type, respectively. NMZLs show overlapping features with other types of MZ, but distinctive features as well. In this review, we will focus on the salient distinguishing features of NMZL mostly under morphological/immunophenotypical/molecular perspectives in views of the recent acquisitions and forthcoming updated 2016 WHO classification of lymphoid malignancies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Quantum anomalies in nodal line semimetals

    Science.gov (United States)

    Burkov, A. A.

    2018-04-01

    Topological semimetals are a new class of condensed matter systems with nontrivial electronic structure topology. Their unusual observable properties may often be understood in terms of quantum anomalies. In particular, Weyl and Dirac semimetals, which have point band-touching nodes, are characterized by the chiral anomaly, which leads to the Fermi arc surface states, anomalous Hall effect, negative longitudinal magnetoresistance, and planar Hall effect. In this paper, we explore analogous phenomena in nodal line semimetals. We demonstrate that such semimetals realize a three-dimensional analog of the parity anomaly, which is a known property of two-dimensional Dirac semimetals arising, for example, on the surface of a three-dimensional topological insulator. We relate one of the characteristic properties of nodal line semimetals, namely, the drumhead surface states, to this anomaly, and derive the field theory, which encodes the corresponding anomalous response.

  7. Temporal quadratic expansion nodal Green's function method

    International Nuclear Information System (INIS)

    Liu Cong; Jing Xingqing; Xu Xiaolin

    2000-01-01

    A new approach is presented to efficiently solve the three-dimensional space-time reactor dynamics equation which overcomes the disadvantages of current methods. In the Temporal Quadratic Expansion Nodal Green's Function Method (TQE/NGFM), the Quadratic Expansion Method (QEM) is used for the temporal solution with the Nodal Green's Function Method (NGFM) employed for the spatial solution. Test calculational results using TQE/NGFM show that its time step size can be 5-20 times larger than that of the Fully Implicit Method (FIM) for similar precision. Additionally, the spatial mesh size with NGFM can be nearly 20 times larger than that using the finite difference method. So, TQE/NGFM is proved to be an efficient reactor dynamics analysis method

  8. Acceleration of the FERM nodal program

    International Nuclear Information System (INIS)

    Nakata, H.

    1985-01-01

    It was tested three acceleration methods trying to reduce the number of outer iterations in the FERM nodal program. The results obtained indicated that the Chebychev polynomial acceleration method with variable degree results in a economy of 50% in the computer time. Otherwise, the acceleration method by source asymptotic extrapolation or by zonal rebalance did not result in economy of the global computer time, however some acceleration had been verified in outer iterations. (M.C.K.) [pt

  9. Acceleration of the nodal program FERM

    International Nuclear Information System (INIS)

    Nakata, H.

    1985-01-01

    Acceleration of the nodal FERM was tried by three acceleration schemes. Results of the calculations showed the best acceleration with the Tchebyshev method where the savings in the computing time were of the order of 50%. Acceleration with the Assymptotic Source Extrapoltation Method and with the Coarse-Mesh Rebalancing Method did not result in any improvement on the global computational time, although a reduction in the number of outer iterations was observed. (Author) [pt

  10. Nodal method for fast reactor analysis

    International Nuclear Information System (INIS)

    Shober, R.A.

    1979-01-01

    In this paper, a nodal method applicable to fast reactor diffusion theory analysis has been developed. This method has been shown to be accurate and efficient in comparison to highly optimized finite difference techniques. The use of an analytic solution to the diffusion equation as a means of determining accurate coupling relationships between nodes has been shown to be highly accurate and efficient in specific two-group applications, as well as in the current multigroup method

  11. Nodal methods in numerical reactor calculations

    International Nuclear Information System (INIS)

    Hennart, J.P.; Valle, E. del

    2004-01-01

    The present work describes the antecedents, developments and applications started in 1972 with Prof. Hennart who was invited to be part of the staff of the Nuclear Engineering Department at the School of Physics and Mathematics of the National Polytechnic Institute. Since that time and up to 1981, several master theses based on classical finite element methods were developed with applications in point kinetics and in the steady state as well as the time dependent multigroup diffusion equations. After this period the emphasis moved to nodal finite elements in 1, 2 and 3D cartesian geometries. All the thesis were devoted to the numerical solution of the neutron multigroup diffusion and transport equations, few of them including the time dependence, most of them related with steady state diffusion equations. The main contributions were as follows: high order nodal schemes for the primal and mixed forms of the diffusion equations, block-centered finite-differences methods, post-processing, composite nodal finite elements for hexagons, and weakly and strongly discontinuous schemes for the transport equation. Some of these are now being used by several researchers involved in nuclear fuel management. (Author)

  12. Nodal methods in numerical reactor calculations

    Energy Technology Data Exchange (ETDEWEB)

    Hennart, J P [UNAM, IIMAS, A.P. 20-726, 01000 Mexico D.F. (Mexico); Valle, E del [National Polytechnic Institute, School of Physics and Mathematics, Department of Nuclear Engineering, Mexico, D.F. (Mexico)

    2004-07-01

    The present work describes the antecedents, developments and applications started in 1972 with Prof. Hennart who was invited to be part of the staff of the Nuclear Engineering Department at the School of Physics and Mathematics of the National Polytechnic Institute. Since that time and up to 1981, several master theses based on classical finite element methods were developed with applications in point kinetics and in the steady state as well as the time dependent multigroup diffusion equations. After this period the emphasis moved to nodal finite elements in 1, 2 and 3D cartesian geometries. All the thesis were devoted to the numerical solution of the neutron multigroup diffusion and transport equations, few of them including the time dependence, most of them related with steady state diffusion equations. The main contributions were as follows: high order nodal schemes for the primal and mixed forms of the diffusion equations, block-centered finite-differences methods, post-processing, composite nodal finite elements for hexagons, and weakly and strongly discontinuous schemes for the transport equation. Some of these are now being used by several researchers involved in nuclear fuel management. (Author)

  13. Pelvic floor physical therapy in urogynecologic disorders.

    Science.gov (United States)

    Kotarinos, Rhonda K

    2003-08-01

    Physical therapists are uniquely qualified to treat pelvic floor dysfunction with conservative management techniques. Techniques associated with incontinence and support functions of the pelvic floor include bladder training and pelvic floor rehabilitation: pelvic floor exercises, biofeedback therapy, and pelvic floor electrical stimulation. Pain associated with mechanical pelvic floor dysfunction can be treated by physical therapists utilizing various manual techniques and modalities. Research documents that conservative management is effective in treating many conditions associated with pelvic floor dysfunction. Research should be conducted to determine if addressing diastasis recti and contracture of the pelvic floor musculature should be a component of the standard physical therapy protocol.

  14. On the non-uniqueness of the nodal mathematical adjoint

    International Nuclear Information System (INIS)

    Müller, Erwin

    2014-01-01

    Highlights: • We evaluate three CMFD schemes for computing the nodal mathematical adjoint. • The nodal mathematical adjoint is not unique and can be non-positive (nonphysical). • Adjoint and forward eigenmodes are compatible if produced by the same CMFD method. • In nodal applications the excited eigenmodes are purely mathematical entities. - Abstract: Computation of the neutron adjoint flux within the framework of modern nodal diffusion methods is often facilitated by reducing the nodal equation system for the forward flux into a simpler coarse-mesh finite-difference form and then transposing the resultant matrix equations. The solution to the transposed problem is known as the nodal mathematical adjoint. Since the coarse-mesh finite-difference reduction of a given nodal formulation can be obtained in a number of ways, different nodal mathematical adjoint solutions can be computed. This non-uniqueness of the nodal mathematical adjoint challenges the credibility of the reduction strategy and demands a verdict as to its suitability in practical applications. This is the matter under consideration in this paper. A selected number of coarse-mesh finite-difference reduction schemes are described and compared. Numerical calculations are utilised to illustrate the differences in the adjoint solutions as well as to appraise the impact on such common applications as the computation of core point kinetics parameters. Recommendations are made for the proper application of the coarse-mesh finite-difference reduction approach to the nodal mathematical adjoint problem

  15. Impacts of Contingency Reserve on Nodal Price and Nodal Reliability Risk in Deregulated Power Systems

    DEFF Research Database (Denmark)

    Zhao, Qian; Wang, Peng; Goel, Lalit

    2013-01-01

    The deregulation of power systems allows customers to participate in power market operation. In deregulated power systems, nodal price and nodal reliability are adopted to represent locational operation cost and reliability performance. Since contingency reserve (CR) plays an important role...... in reliable operation, the CR commitment should be considered in operational reliability analysis. In this paper, a CR model based on customer reliability requirements has been formulated and integrated into power market settlement. A two-step market clearing process has been proposed to determine generation...

  16. Pelvic Muscle Rehabilitation: A Standardized Protocol for Pelvic Floor Dysfunction

    Directory of Open Access Journals (Sweden)

    Rodrigo Pedraza

    2014-01-01

    Full Text Available Introduction. Pelvic floor dysfunction syndromes present with voiding, sexual, and anorectal disturbances, which may be associated with one another, resulting in complex presentation. Thus, an integrated diagnosis and management approach may be required. Pelvic muscle rehabilitation (PMR is a noninvasive modality involving cognitive reeducation, modification, and retraining of the pelvic floor and associated musculature. We describe our standardized PMR protocol for the management of pelvic floor dysfunction syndromes. Pelvic Muscle Rehabilitation Program. The diagnostic assessment includes electromyography and manometry analyzed in 4 phases: (1 initial baseline phase; (2 rapid contraction phase; (3 tonic contraction and endurance phase; and (4 late baseline phase. This evaluation is performed at the onset of every session. PMR management consists of 6 possible therapeutic modalities, employed depending on the diagnostic evaluation: (1 down-training; (2 accessory muscle isolation; (3 discrimination training; (4 muscle strengthening; (5 endurance training; and (6 electrical stimulation. Eight to ten sessions are performed at one-week intervals with integration of home exercises and lifestyle modifications. Conclusions. The PMR protocol offers a standardized approach to diagnose and manage pelvic floor dysfunction syndromes with potential advantages over traditional biofeedback, involving additional interventions and a continuous pelvic floor assessment with management modifications over the clinical course.

  17. [Pay attention to the selective lateral pelvic lymph node dissection in mid-low rectal cancer].

    Science.gov (United States)

    Meng, Wenjian; Wang, Ziqiang

    2017-03-25

    Lateral pelvic lymph node metastasis is an important metastatic mode and a major cause of locoregional recurrence of mid-low rectal cancer. Recently, there is an East-West discrepancy in regard to the diagnosis, clinical significance, treatment and prognosis of lateral pelvic lymph node metastasis. In the West, lateral nodal involvement may represent systemic disease and preoperative chemoradiotherapy can sterilize clinically suspected lateral nodes. Thus, in many Western countries, the standard therapy for lower rectal cancer is total mesorectal excision with chemoradiotherapy, and pelvic sidewall dissection is rarely performed. In the East, and Japan in particular, however, there is a positive attitude in regard to lateral pelvic lymph node dissection (LPND). They consider that lateral pelvic lymph node metastasis is as regional metastasis, and the clinically suspected lateral nodes can not be removed by neoadjuvant chemoradiotherapy. The selective LPND after neoadjuvant chemoradiotherapy may be found to be promising treatment for the improvement of therapeutic benefits in these patients. Therefore, the large-scale prospective studies are urgently required to improve selection criteria for LPND and neoadjuvant treatment to prevent overtreatment in the near future. Selective LPND after neoadjuvant treatment based on modern imaging techniques is expected to reduce locoregional recurrence and improve long-term survival in patients with mid-low rectal cancer.

  18. Topological surface states in nodal superconductors.

    Science.gov (United States)

    Schnyder, Andreas P; Brydon, Philip M R

    2015-06-24

    Topological superconductors have become a subject of intense research due to their potential use for technical applications in device fabrication and quantum information. Besides fully gapped superconductors, unconventional superconductors with point or line nodes in their order parameter can also exhibit nontrivial topological characteristics. This article reviews recent progress in the theoretical understanding of nodal topological superconductors, with a focus on Weyl and noncentrosymmetric superconductors and their protected surface states. Using selected examples, we review the bulk topological properties of these systems, study different types of topological surface states, and examine their unusual properties. Furthermore, we survey some candidate materials for topological superconductivity and discuss different experimental signatures of topological surface states.

  19. Twisted vector bundles on pointed nodal curves

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    by identifying the points p1 and p2. If m ≥ 2, let R1,...,Rm−1 be m − 1 copies of the projective line P1 and let xi,yi be two distinct points in Ri. Let R be the nodal curve which arises from the union. R0 ⊔ R1 ⊔···⊔ Rm−1 ⊔ Rm by identifying p1 ∈ R0 and p2 ∈ Rm with x1 ∈ R1 and ym−1 ∈ Rm−1 respectively and by identifying ...

  20. Ovarian irradiation in recurrent endometriosis; Irradiation ovarienne pour endometriose refractaire inoperable

    Energy Technology Data Exchange (ETDEWEB)

    Kochbati, L.; Chaari, N.; Besbes, M.; Maalej, M. [Institut Salah-Azaiz, Service de Radiotherapie Carcinologique Tunis (Tunisia); Neji, K.; Ben Amara, F. [Centre de Maternite et de Neonatologie de Tunis, Service B (Tunisia); Ben Romdhane, N.K. [Hopital La-Rabta, Service d' Hematologie, Tunis (Tunisia)

    2005-09-15

    We describe a case of a young woman with a history of an aplastic anaemia in which pelvic radiotherapy was used successfully in the management of a recurrent and inoperable endometriosis. The use of therapeutic pelvic or ovarian irradiation in endometriosis may be considered, when surgical and medical treatments have been exhausted and have failed. (authors)

  1. Pelvic denervation procedures for dysmenorrhea.

    Science.gov (United States)

    Ramirez, Christina; Donnellan, Nicole

    2017-08-01

    Chronic pelvic pain and dysmenorrhea are common conditions affecting reproductive-age women. Surgical pelvic denervation procedures may be a treatment option for women with midline dysmenorrhea, in which medical management is declined by the patient, ineffective at managing symptoms, or medically contraindicated. This review describes the surgical techniques and complications associated with pelvic denervation procedures as well as the current evidence for these procedures in women with primary dysmenorrhea and dysmenorrhea secondary to endometriosis. Presacral neurectomy is the preferred pelvic denervation procedure in patients with primary dysmenorrhea and midline chronic pelvic pain associated with endometriosis. In patients with endometriosis presacral neurectomy is a useful adjunct to excision or ablation of all endometrial lesions to improve postoperative pain relief. There is no additional patient benefit of performing combined presacral neurectomy and uterine nerve ablation procedures. Pelvic denervation procedures can be performed safely and quickly with a low risk of complication if the surgeon is knowledgeable and skilled in operating in the presacral space. Patients should be adequately counseled on expected success rates and potential complications associated with pelvic denervation procedures.

  2. Regional nodal relapse in surgically staged Merkel cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Hoeller, Ulrike; Mueller, Thomas; Schubert, Tina; Budach, Volker; Ghadjar, Pirus [Charite Universitaetsmedizin Berlin, Department of Radiation Oncology, Berlin (Germany); Brenner, Winfried [Charite Universitaetsmedizin Berlin, Department of Nuclear Medicine, Berlin (Germany); Kiecker, Felix [Charite Universitaetsmedizin Berlin, Department of Dermatology, Berlin (Germany); Schicke, Bernd [Tumor Center Berlin, Berlin (Germany); Haase, Oliver [Charite Universitaetsmedizin Berlin, Department of Surgery, Berlin (Germany)

    2014-10-08

    The nodal relapse pattern of surgically staged Merkel cell carcinoma (MCC) with/without elective nodal radiotherapy (RT) was studied in a single institution. A total of 51 patients with MCC, 33 % UICC stage I, 14 % II, 53 % III (4 lymph node metastases of unknown primary) were eligible. All patients had surgical staging: 23 patients sentinel node biopsy (SNB), 22 patients SNB followed by lymphadenectomy (LAD) and 6 patients LAD. In all, 94 % of the primary tumors (PT) were completely resected; 57 % of patients received RT, 51 % of known PT sites, 33 % (8/24 patients) regional RT to snN0 nodes and 68 % (17/27 patients) to pN+ nodes, mean reference dose 51.5 and 50 Gy, respectively. Mean follow-up was 6 years (range 2-14 years). A total of 22 % (11/51) patients developed regional relapses (RR); the 5-year RR rate was 27 %. In snN0 sites (stage I/II), relapse occurred in 5 of 14 nonirradiated vs. none of 8 irradiated sites (p = 0.054), resulting in a 5-year RR rate of 33 % versus 0 % (p = 0.16). The crude RR rate was lower in stage I (12 %, 2/17 patients) than for stage II (43 %, 3/7 patients). In stage III (pN+), RR appeared to be less frequent in irradiated sites (18 %, 3/14 patients) compared with nonirradiated sites (33 %, 3/10 patients, p = 0.45) with 5-year RR rates of 23 % vs. 34 %, respectively. Our data suggest that adjuvant nodal RT plays a major role even if the sentinel nodes were negative. Adjuvant RT of the lymph nodes in patients with stage IIa tumors and RT after LAD in stage III tumors is proposed and should be evaluated prospectively. (orig.) [German] Untersucht wurde das regionaere Rezidivmuster des Merkelzell-Karzinoms (MCC) nach chirurgischem Staging und stadienadaptierter Therapie. Eingeschlossen wurden 51 Patienten mit lokalisiertem MCC: 33 % hatten UICC-Stadium-I-, 14 % -II-, 53 % -III-Tumoren (davon 4 Lymphknotenmetastasen eines unbekannten Primaertumors). Alle Patienten erhielten ein chirurgisches Staging: 23 Waechterlymphknotenbiopsien (SNB

  3. Robust doubly charged nodal lines and nodal surfaces in centrosymmetric systems

    Science.gov (United States)

    Bzdušek, Tomáš; Sigrist, Manfred

    2017-10-01

    Weyl points in three spatial dimensions are characterized by a Z -valued charge—the Chern number—which makes them stable against a wide range of perturbations. A set of Weyl points can mutually annihilate only if their net charge vanishes, a property we refer to as robustness. While nodal loops are usually not robust in this sense, it has recently been shown using homotopy arguments that in the centrosymmetric extension of the AI symmetry class they nevertheless develop a Z2 charge analogous to the Chern number. Nodal loops carrying a nontrivial value of this Z2 charge are robust, i.e., they can be gapped out only by a pairwise annihilation and not on their own. As this is an additional charge independent of the Berry π -phase flowing along the band degeneracy, such nodal loops are, in fact, doubly charged. In this manuscript, we generalize the homotopy discussion to the centrosymmetric extensions of all Atland-Zirnbauer classes. We develop a tailored mathematical framework dubbed the AZ +I classification and show that in three spatial dimensions such robust and multiply charged nodes appear in four of such centrosymmetric extensions, namely, AZ +I classes CI and AI lead to doubly charged nodal lines, while D and BDI support doubly charged nodal surfaces. We remark that no further crystalline symmetries apart from the spatial inversion are necessary for their stability. We provide a description of the corresponding topological charges, and develop simple tight-binding models of various semimetallic and superconducting phases that exhibit these nodes. We also indicate how the concept of robust and multiply charged nodes generalizes to other spatial dimensions.

  4. Error estimation for variational nodal calculations

    International Nuclear Information System (INIS)

    Zhang, H.; Lewis, E.E.

    1998-01-01

    Adaptive grid methods are widely employed in finite element solutions to both solid and fluid mechanics problems. Either the size of the element is reduced (h refinement) or the order of the trial function is increased (p refinement) locally to improve the accuracy of the solution without a commensurate increase in computational effort. Success of these methods requires effective local error estimates to determine those parts of the problem domain where the solution should be refined. Adaptive methods have recently been applied to the spatial variables of the discrete ordinates equations. As a first step in the development of adaptive methods that are compatible with the variational nodal method, the authors examine error estimates for use in conjunction with spatial variables. The variational nodal method lends itself well to p refinement because the space-angle trial functions are hierarchical. Here they examine an error estimator for use with spatial p refinement for the diffusion approximation. Eventually, angular refinement will also be considered using spherical harmonics approximations

  5. Radiographic assessment of pelvic trauma

    International Nuclear Information System (INIS)

    Rubenstein, J.D.

    1983-01-01

    Assessment of pelvic fractures requires an understanding of the bony and soft-tissue anatomy of the pelvis. Pelvic injuries may be classified into major and minor groups. Minor fractures usually result from athletic trauma in the young or falls in the elderly and can generally be adequately evaluated with routine radiography. Major fractures are most often caused by motor vehicle accidents, falls from a height or industrial accidents and require more sophisticated examination. However, the investigation of injuries in either category should be directed by a knowledge of the history and physical findings. The classification of pelvic injuries used at Sunnbrook Medical Centre is based on mechanisms of injury

  6. Adjuvant radiotherapy after salvage lymph node dissection because of nodal relapse of prostate cancer versus salvage lymph node dissection only

    International Nuclear Information System (INIS)

    Rischke, Hans Christian; Schultze-Seemann, Wolfgang; Kroenig, Malte; Schlager, Daniel; Jilg, Cordula Annette; Wieser, Gesche; Drendel, Vanessa; Stegmaier, Petra; Henne, Karl; Volegova-Neher, Natalia; Grosu, Anca-Ligia; Krauss, Tobias; Kirste, Simon

    2015-01-01

    Nodal pelvic/retroperitoneal recurrent prostate cancer (PCa) after primary therapy can be treated with salvage lymph node dissection (salvage-LND) in order to delay disease progression and offer cure for a subset of patients. Whether adjuvant radiotherapy (ART) in affected regions improves the outcome by elimination of residual tumour burden remains unclear. A total of 93 patients with exclusively nodal PCa relapse underwent choline-positron-emission tomography-computed-tomography-directed pelvic/retroperitoneal salvage-LND; 46 patients had surgery only and 47 patients received ART in regions with proven lymph node metastases. In case of subsequent prostate specific antigen (PSA) progression, different imaging modalities were performed to confirm next relapse within or outside the treated region (TR). Mean follow-up was 3.2 years. Lymphatic tumour burden was balanced between the two groups. Additional ART resulted in delayed relapse within TR (5-year relapse-free rate 70.7 %) versus surgery only (5-year relapse-free rate 26.3 %, p < 0.0001). In both treatment arms, time to next relapse outside the TR was almost equal (median 27 months versus 29.6 months, p = 0.359). With respect to the detection of the first new lesion, regardless if present within or outside the TR, 5 years after the treatment 34.3 % of patients in the group with additional ART were free of relapse, versus 15.4 % in the surgery only group (p = 0.0122). ART had no influence on the extent of PSA reduction at latest follow-up compared to treatment with surgery only. ART after salvage-LND provides stable local control in TR and results in overall significant improved next-relapse-free survival, compared to patients who received surgery only in case of nodal PCa-relapse. (orig.) [de

  7. Tolerance and efficiency of radiation therapy treatment of the pelvic lymph nodes in patients with prostate cancer

    International Nuclear Information System (INIS)

    Hegemann, Nina-Sophie

    2013-01-01

    Tolerance and efficiency of radiation therapy treatment of the pelvic lymph nodes were assessed in 122 patients with prostate cancer. With no severe observed late toxicity the incidence for lymph node metastases was between 3,0% (primarily irradiated patients without lymph node or distant metastases) and 100% (primarily irradiated patients with lymph node and distant metastases) after 3 years. As it seems, the following subgroups might possibly profit the most from a dose escalation in the pelvic lymph nodes: primarily irradiated patients with positive lymph nodes and postoperatively irradiated patients in adjuvant/additive situation, with a biochemical or a local/lymph node recurrence.

  8. Post-irradiation diarrhea

    International Nuclear Information System (INIS)

    Meerwaldt, J.H.

    1984-01-01

    In radiotherapy of pelvic cancers, the X-ray dose to be delivered to the tumour is limited by the tolerance of healthy surrounding tissue. In recent years, a number of serious complications of irradiation of pelvic organs were encountered. Modern radiotherapy necessitates the acceptance of a calculated risk of complications in order to achieve a better cure rate. To calculate these risks, one has to know the radiation dose-effect relationship of normal tissues. Of the normal tissues most at risk when treating pelvic tumours only the bowel is studied. In the literature regarding post-irradiation bowel complications, severe and mild complications are often mixed. In the present investigation the author concentrated on the group of patients with relatively mild symptoms. He studied the incidence and course of post-irradiation diarrhea in 196 patients treated for carcinoma of the uterine cervix or endometrium. The aims of the present study were: 1) to determine the incidence, course and prognostic significance of post-irradiation diarrhea; 2) to assess the influence of radiotherapy factors; 3) to study the relation of bile acid metabolism to post-irradiation diarrhea; 4) to investigate whether local factors (reservoir function) were primarily responsible. (Auth.)

  9. A consensus-based guideline defining the clinical target volume for pelvic lymph nodes in external beam radiotherapy for uterine cervical cancer

    International Nuclear Information System (INIS)

    Toita, Takafumi; Ohno, Tatsuya; Kaneyasu, Yuko

    2010-01-01

    The objective of this study was to develop a consensus-based guideline as well as an atlas defining pelvic nodal clinical target volumes in external beam radiotherapy for uterine cervical cancer. A working subgroup to establish the consensus-based guideline on clinical target volumes for uterine cervical cancer was formulated by the Radiation Therapy Study Group of the Japan Clinical Oncology Group in July 2008. The working subgroup consisted of seven radiation oncologists. The process resulting in the consensus included a comparison of contouring on CT images among the members, reviewing of published textbooks and the relevant literature and a distribution analysis of metastatic nodes on computed tomography/magnetic resonance imaging of actual patients. The working subgroup defined the pelvic nodal clinical target volumes for cervical cancer and developed an associated atlas. As a basic criterion, the lymph node clinical target volume was defined as the area encompassed by a 7 mm margin around the applicable pelvic vessels. Modifications were made in each nodal area to cover adjacent adipose tissues at risk of microscopic nodal metastases. Although the bones and muscles were excluded, the bowel was not routinely excluded in the definition. Each of the following pelvic node regions was defined: common iliac, external iliac, internal iliac, obturator and presacral. Anatomical structures bordering each lymph node region were defined for six directions; anterior, posterior, lateral, medial, cranial and caudal. Drafts of the definition and the atlas were reviewed by members of the JCOG Gynecologic Cancer Study Group (GCSG). We developed a consensus-based guideline defining the pelvic node clinical target volumes that included an atlas. The guideline will be continuously updated to reflect the ongoing changes in the field. (author)

  10. Pelvic Inflammatory Disease (PID) Statistics

    Science.gov (United States)

    ... Home Page Bacterial Vaginosis (BV) Chlamydia Genital Herpes Gonorrhea Hepatitis HIV/AIDS & STDs Human Papillomavirus (HPV) Pelvic ... last 12 months that they had chlamydia or gonorrhea or have ever been told they have herpes, ...

  11. How Is Pelvic Pain Diagnosed?

    Science.gov (United States)

    ... NICHD Research Information Find a Study More Information Pharmacology Condition Information NICHD Research Information Find a Study ... button to look inside the pelvis 4 Pelvic MRI (magnetic resonance imaging) scan, an imaging test that ...

  12. Torsionfree Sheaves over a Nodal Curve of Arithmetic Genus One

    Indian Academy of Sciences (India)

    We classify all isomorphism classes of stable torsionfree sheaves on an irreducible nodal curve of arithmetic genus one defined over C C . Let be a nodal curve of arithmetic genus one defined over R R , with exactly one node, such that does not have any real points apart from the node. We classify all isomorphism ...

  13. Interventional Management for Pelvic Pain.

    Science.gov (United States)

    Nagpal, Ameet S; Moody, Erika L

    2017-08-01

    Interventional procedures can be applied for diagnostic evaluation and treatment of the patient with pelvic pain, often once more conservative measures have failed to provide relief. This article reviews interventional management strategies for pelvic pain. We review superior and inferior hypogastric plexus blocks, ganglion impar blocks, transversus abdominis plane blocks, ilioinguinal, iliohypogastric and genitofemoral blocks, pudendal nerve blocks, and selective nerve root blocks. Additionally, we discuss trigger point injections, sacroiliac joint injections, and neuromodulation approaches. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Clinical and anatomical guidelines in pelvic cancer contouring for radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Portaluri, M.; Bambace, S.; Giuliano, G.; Pili, G.; Didonna, V.; Perez, C.; Angone, G.; Alloro, E.; Scialpi, M.

    2004-01-01

    Background and purpose. Many observations on potential inadequate coverage of tumour volume at risk in advanced cervical cancer (CC) when conventional radiation fields are used, have further substantiated by investigators using MRI, CT or lymph-angiographic imaging. This work tries to obtain three dimensional margins by observing enlarged nodes in CT scans in order to improve pelvic nodal chains clinical target volumes (CTVs) drawing, and by looking for corroborative evidence in the literature for a better delineation of tumour CTV. Method. Eleven consecutive patients (seven males, four females, mean age 62 years, range 43 8) with CT diagnosis of nodal involvement caused by pathologically proved carcinoma of the cervix (n = 2), carcinoma of the rectum (n = 2), carcinoma of the prostate (n = 2), non-Hodgkin lymphoma (n 2), Hodgkin lymphoma (n = 1), carcinoma of the penis (n = 1) and carcinoma of the corpus uteri (n = 1) were retrospectively reviewed. Sixty CT scans with 67 enlarged pelvic nodes were reviewed in order to record the more proximal structures (muscle, bone, vessels, cutis or sub-cutis and other organs) to each enlarged node or group of nodes according to the four surfaces (anterior, lateral, posterior and medial) in a clockwise direction. Results. summary of the observations of each nodal chain and the number of occurrences of every marginal structure on axial CT slices is presented. Finally, simple guidelines are proposed. Conclusions. Tumour CTV should be based on individual tumour anatomy mainly for lateral beams as it results from sagittal T2 weighted MRI images. Boundaries of pelvic nodes CTVs can be derived from observations of enlarged lymph nodes in CT scans. (author)

  15. A nodalization study of steam separator in real time simulation

    International Nuclear Information System (INIS)

    Horugshyang, Lein; Luh, R.T.J.; Zen-Yow, Wang

    1999-01-01

    The motive of this paper is to investigate the influence of steam separator nodalization on reactor thermohydraulics in terms of stability and level response. Three different nodalizations of steam separator are studied by using THEATRE and REMARK Code in a BWR simulator. The first nodalization is the traditional one with two nodes for steam separator. In this nodalization, the steam separation is modeled in the outer node, i.e., upper downcomer. Separated steam enters the Steen dome node and the liquid goes to the feedwater node. The second nodalization is similar to the first one with the steam separation modeled in the inner node. There is one additional junction connecting steam dome node and the inner node. The liquid fallback junction connects the inner node and feedwater node. The third nodalization is a combination of the former two with an integrated node for steam separator. Boundary conditions in this study are provided by a simplified feedwater and main steam driver. For comparison purpose, three tests including full power steady state initialisation, recirculation pumps runback and reactor scram are conducted. Major parameters such as reactor pressure, reactor level, void fractions, neutronic power and junction flows are recorded for analysis. Test results clearly show that the first nodalization is stable for steady state initialisation. However it has too responsive level performance in core flow reduction transients. The second nodalization is the closest representation of real plant structure, but not the performance. Test results show that an instability occurs in the separator region for both steady state initialisation and transients. This instability is caused by an unbalanced momentum in the dual loop configuration. The magnitude of the oscillation reduces as the power decreases. No superiority to the other nodalizations is shown in the test results. The third nodalization shows both stability and responsiveness in the tests. (author)

  16. Topological surface states in nodal superconductors

    International Nuclear Information System (INIS)

    Schnyder, Andreas P; Brydon, Philip M R

    2015-01-01

    Topological superconductors have become a subject of intense research due to their potential use for technical applications in device fabrication and quantum information. Besides fully gapped superconductors, unconventional superconductors with point or line nodes in their order parameter can also exhibit nontrivial topological characteristics. This article reviews recent progress in the theoretical understanding of nodal topological superconductors, with a focus on Weyl and noncentrosymmetric superconductors and their protected surface states. Using selected examples, we review the bulk topological properties of these systems, study different types of topological surface states, and examine their unusual properties. Furthermore, we survey some candidate materials for topological superconductivity and discuss different experimental signatures of topological surface states. (topical review)

  17. Nodal aberration theory applied to freeform surfaces

    Science.gov (United States)

    Fuerschbach, Kyle; Rolland, Jannick P.; Thompson, Kevin P.

    2014-12-01

    When new three-dimensional packages are developed for imaging optical systems, the rotational symmetry of the optical system is often broken, changing its imaging behavior and making the optical performance worse. A method to restore the performance is to use freeform optical surfaces that compensate directly the aberrations introduced from tilting and decentering the optical surfaces. In order to effectively optimize the shape of a freeform surface to restore optical functionality, it is helpful to understand the aberration effect the surface may induce. Using nodal aberration theory the aberration fields induced by a freeform surface in an optical system are explored. These theoretical predications are experimentally validated with the design and implementation of an aberration generating telescope.

  18. A nodal expansion method using conformal mapping for hexagonal geometry

    International Nuclear Information System (INIS)

    Chao, Y.A.; Shatilla, Y.A.

    1993-01-01

    Hexagonal nodal methods adopting the same transverse integration process used for square nodal methods face the subtle theoretical problem that this process leads to highly singular nonphysical terms in the diffusion equation. Lawrence, in developing the DIF3D-N code, tried to approximate the singular terms with relatively simple polynomials. In the HEX-NOD code, Wagner ignored the singularities to simplify the diffusion equation and introduced compensating terms in the nodal equations to restore the nodal balance relation. More recently developed hexagonal nodal codes, such as HEXPE-DITE and the hexagonal version of PANTHER, used methods similar to Wagner's. It will be shown that for light water reactor applications, these two different approximations significantly degraded the accuracy of the respective method as compared to the established square nodal methods. Alternatively, the method of conformal mapping was suggested to map a hexagon to a rectangle, with the unique feature of leaving the diffusion operator invariant, thereby fundamentally resolving the problems associated with transverse integration. This method is now implemented in the Westinghouse hexagonal nodal code ANC-H. In this paper we report on the results of comparing the three methods for a variety of problems via benchmarking against the fine-mesh finite difference code

  19. Benchmarking with high-order nodal diffusion methods

    International Nuclear Information System (INIS)

    Tomasevic, D.; Larsen, E.W.

    1993-01-01

    Significant progress in the solution of multidimensional neutron diffusion problems was made in the late 1970s with the introduction of nodal methods. Modern nodal reactor analysis codes provide significant improvements in both accuracy and computing speed over earlier codes based on fine-mesh finite difference methods. In the past, the performance of advanced nodal methods was determined by comparisons with fine-mesh finite difference codes. More recently, the excellent spatial convergence of nodal methods has permitted their use in establishing reference solutions for some important bench-mark problems. The recent development of the self-consistent high-order nodal diffusion method and its subsequent variational formulation has permitted the calculation of reference solutions with one node per assembly mesh size. In this paper, we compare results for four selected benchmark problems to those obtained by high-order response matrix methods and by two well-known state-of-the-art nodal methods (the open-quotes analyticalclose quotes and open-quotes nodal expansionclose quotes methods)

  20. Delineation of Internal Mammary Nodal Target Volumes in Breast Cancer Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jethwa, Krishan R.; Kahila, Mohamed M. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Hunt, Katie N. [Department of Radiology, Mayo Clinic, Rochester, Minnesota (United States); Brown, Lindsay C.; Corbin, Kimberly S.; Park, Sean S.; Yan, Elizabeth S. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Boughey, Judy C. [Department of Surgery, Mayo Clinic, Rochester, Minnesota (United States); Mutter, Robert W., E-mail: mutter.robert@mayo.edu [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States)

    2017-03-15

    Purpose: The optimal clinical target volume for internal mammary (IM) node irradiation is uncertain in an era of increasingly conformal volume-based treatment planning for breast cancer. We mapped the location of gross internal mammary lymph node (IMN) metastases to identify areas at highest risk of harboring occult disease. Methods and Materials: Patients with axial imaging of IMN disease were identified from a breast cancer registry. The IMN location was transferred onto the corresponding anatomic position on representative axial computed tomography images of a patient in the treatment position and compared with consensus group guidelines of IMN target delineation. Results: The IMN location in 67 patients with 130 IMN metastases was mapped. The location was in the first 3 intercostal spaces in 102 of 130 nodal metastases (78%), whereas 18 of 130 IMNs (14%) were located caudal to the third intercostal space and 10 of 130 IMNs (8%) were located cranial to the first intercostal space. Of the 102 nodal metastases within the first 3 intercostal spaces, 54 (53%) were located within the Radiation Therapy Oncology Group consensus volume. Relative to the IM vessels, 19 nodal metastases (19%) were located medially with a mean distance of 2.2 mm (SD, 2.9 mm) whereas 29 (28%) were located laterally with a mean distance of 3.6 mm (SD, 2.5 mm). Ninety percent of lymph nodes within the first 3 intercostal spaces would have been encompassed within a 4-mm medial and lateral expansion on the IM vessels. Conclusions: In women with indications for elective IMN irradiation, a 4-mm medial and lateral expansion on the IM vessels may be appropriate. In women with known IMN involvement, cranial extension to the confluence of the IM vein with the brachiocephalic vein with or without caudal extension to the fourth or fifth interspace may be considered provided that normal tissue constraints are met.

  1. Functional anatomy of pelvic floor

    Directory of Open Access Journals (Sweden)

    Salvatore Rocca Rossetti

    2016-03-01

    Full Text Available Generally, descriptions of the pelvic floor are discordant, since its complex structures and the complexity of pathological disorders of such structures; commonly the descriptions are sectorial, concerning muscles, fascial developments, ligaments and so on. On the contrary to understand completely nature and function of the pelvic floor it is necessary to study it in the most unitary view and in the most global aspect, considering embriology, philogenesy, anthropologic development and its multiple activities others than urological, gynaecological and intestinal ones. Recent acquirements succeeded in clarifying many aspects of pelvic floor activity, whose musculature has been investigated through electromyography, sonography, magnetic resonance, histology, histochemistry, molecular research. Utilizing recent research concerning not only urinary and gynecologic aspects but also those regarding statics and dynamics of pelvis and its floor, it is now possible to study this important body part as a unit; that means to consider it in the whole body economy to which maintaining upright position, walking and behavior or physical conduct do not share less than urinary, genital, and intestinal functions. It is today possible to consider the pelvic floor as a musclefascial unit with synergic and antagonistic activity of muscular bundles, among them more or less interlaced, with multiple functions and not only the function of pelvic cup closure.

  2. A Hennart nodal method for the diffusion equation

    International Nuclear Information System (INIS)

    Lesaint, P.; Noceir, S.; Verwaerde, D.

    1995-01-01

    A modification of the Hennart nodal method for neutron diffusion problems is presented. The final system of equations obtained by this method is not positive definite. However, a flux elimination technique leads to a simple positive definite system, which can be solved by the traditional iterative methods. Calculations of a two-dimensional International Atomic Energy Agency benchmark problem are performed and compared with results of the original Hennart nodal method and some finite element methods. The high computational efficiency of this modified nodal method is clearly demonstrated

  3. Modifying nodal pricing method considering market participants optimality and reliability

    Directory of Open Access Journals (Sweden)

    A. R. Soofiabadi

    2015-06-01

    Full Text Available This paper develops a method for nodal pricing and market clearing mechanism considering reliability of the system. The effects of components reliability on electricity price, market participants’ profit and system social welfare is considered. This paper considers reliability both for evaluation of market participant’s optimality as well as for fair pricing and market clearing mechanism. To achieve fair pricing, nodal price has been obtained through a two stage optimization problem and to achieve fair market clearing mechanism, comprehensive criteria has been introduced for optimality evaluation of market participant. Social welfare of the system and system efficiency are increased under proposed modified nodal pricing method.

  4. Toxicity and quality of life after choline-PET/CT directed salvage lymph node dissection and adjuvant radiotherapy in nodal recurrent prostate cancer

    International Nuclear Information System (INIS)

    Jilg, Cordula A; Leifert, Anja; Schnell, Daniel; Kirste, Simon; Volegova-Neher, Natalia; Schlager, Daniel; Wieser, Gesche; Henne, Karl; Schultze-Seemann, Wolfgang; Grosu, Anca-L; Rischke, Hans Christian

    2014-01-01

    In a previous study we demonstrated that, based on 11 C/ 18 F-choline positron emission tomography-computerized-tomography as a diagnostic tool, salvage lymph node dissection (LND) plus adjuvant radiotherapy (ART) is feasible for treatment of pelvic/retroperitoneal nodal recurrence of prostate cancer (PCa). However, the toxicity of this combined treatment strategy has not been systematically investigated before. The aim of the current study was to evaluate the acute and late toxicity and quality of life of ART after LND in pelvic/retroperitoneal nodal recurrent PCa. 43 patients with nodal recurrent PCa were treated with 46 LND followed by ART (mean 49.6 Gy total dose) at the sites of nodal recurrence. Toxicity of ART was analysed by physically examination (31/43, 72.1%), by requesting 15 frequent items of adverse events from the Common-Terminology-Criteria for Adverse Events Version 4.0-catalogue and by review of medical records. QLQ-C30 (EORTC quality of life assessment) and PR25 (prostate cancer module) questionnaires were used to investigate quality of life. Toxicity was evaluated before starting of ART, during ART (acute toxicity), after ART (mean 2.3 months) and at end of follow up (mean 3.2 years after end of ART) reflecting late toxicity. 71.7% (33/46) of 46 ART were treatment of pelvic, 10.9% (5/46) of retroperitoneal only and 28.3% (13/46) of pelvic and retroperitoneal regions. Overall 52 symptoms representing toxicities were observed before ART, 107 during ART, 88 after end of ART and 52 at latest follow up. Leading toxicities during ART were diarrhoea (19%, 20/107), urinary incontinence (16%, 17/107) and fatigue (16%, 17/107). The spectrum of late toxicities was almost equal to those before beginning of ART. No grade 3 adverse events or chronic lymphedema at extremities were observed. We observed no clear correlation between localisation of treated regions, technique of ART and frequency or severity of toxicities. Mean quality of life at final evaluation

  5. [Definition of nodal volumes in breast cancer treatment and segmentation guidelines].

    Science.gov (United States)

    Kirova, Y M; Castro Pena, P; Dendale, R; Campana, F; Bollet, M A; Fournier-Bidoz, N; Fourquet, A

    2009-06-01

    To assist in the determination of breast and nodal volumes in the setting of radiotherapy for breast cancer and establish segmentation guidelines. Materials and methods. Contrast metarial enhanced CT examinations were obtained in the treatment position in 25 patients to clearly define the target volumes. The clinical target volume (CTV) including the breast, internal mammary nodes, supraclavicular and subclavicular regions and axxilary region were segmented along with the brachial plexus and interpectoral nodes. The following critical organs were also segmented: heart, lungs, contralateral breast, thyroid, esophagus and humeral head. A correlation between clinical and imaging findings and meeting between radiation oncologists and breast specialists resulted in a better definition of irradiation volumes for breast and nodes with establishement of segmentation guidelines and creation of an anatomical atlas. A practical approach, based on anatomical criteria, is proposed to assist in the segmentation of breast and node volumes in the setting of breast cancer treatment along with a definition of irradiation volumes.

  6. Microbiota and Pelvic Inflammatory Disease

    Science.gov (United States)

    Sharma, Harsha; Tal, Reshef; Clark, Natalie A.; Segars, James H.

    2014-01-01

    Female genital tract microbiota play a crucial role in maintaining health. Disequilibrium of the microbiota has been associated with increased risk of pelvic infections. In recent years, culture-independent molecular techniques have expanded understanding of the composition of genital microbiota and the dynamic nature of the microbiota. There is evidence that upper genital tract may not be sterile and may harbor microflora in the physiologic state. The isolation of bacterial vaginosis-associated organisms in women with genital infections establishes a link between pelvic infections and abnormal vaginal flora. With the understanding of the composition of the microbiota in healthy and diseased states, the next logical step is to identify the function of the newly identified microbes. This knowledge will further expand our understanding of the causation of pelvic infections, which may lead to more effective prevention and treatment strategies. PMID:24390920

  7. Computed tomography of pelvic fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kimoto, Makoto; Hashimoto, Keiji; Hiraki, Yoshio

    1984-12-01

    Plain x-ray and computed tomographic (CT) findings were compared in 7 patients with pelvic fractures (2 males and 5 females) aged between 35 and 50 year. Plain x-rays had a higher sensitivity than CT in detecting fractures of the ischiatic and pubic ramuses, and deviation of bone fragments. CT was superior to plain x-rays near the acetabulum and in detecting deviation of bone fragments. Although there were no differences between the two modalities in detecting fractures of the wing of ilium, CT was more useful than plain x-rays in visualizing deviation of bone fragments. CT clearly visualized not only fractures but also injuries of the soft tissues, such as pelvic viscera and muscles, and the presence of hematoma. CT seems to be a useful method for observing the condition and process of pelvic injuries and for deciding treatment protocols.

  8. Present Status of GNF New Nodal Simulator

    International Nuclear Information System (INIS)

    Iwamoto, T.; Tamitani, M.; Moore, B.

    2001-01-01

    This paper presents core simulator consolidation work done at Global Nuclear Fuel (GNF). The unified simulator needs to supercede the capabilities of past simulator packages from the original GNF partners: GE, Hitachi, and Toshiba. At the same time, an effort is being made to produce a simulation package that will be a state-of-the-art analysis tool when released, in terms of the physics solution methodology and functionality. The core simulator will be capable and qualified for (a) high-energy cycles in the U.S. markets, (b) mixed-oxide (MOX) introduction in Japan, and (c) high-power density plants in Europe, etc. The unification of the lattice physics code is also in progress based on a transport model with collision probability methods. The AETNA core simulator is built upon the PANAC11 software base. The goal is to essentially replace the 1.5-energy-group model with a higher-order multigroup nonlinear nodal solution capable of the required modeling fidelity, while keeping highly automated library generation as well as functionality. All required interfaces to PANAC11 will be preserved, which minimizes the impact on users and process automation. Preliminary results show statistical accuracy improvement over the 1.5-group model

  9. BEACON: An application of nodal methods for operational support

    International Nuclear Information System (INIS)

    Boyd, W.A.; Nguyen, T.Q.

    1992-01-01

    A practical application of nodal methods is on-line plant operational support. However, to enable plant personnel to take full advantage of a nodal model to support plant operations, (a) a core nodal model must always be up to date with the current core history and conditions, (b) the nodal methods must be fast enough to allow numerous core calculations to be performed in minutes to support engineering decisions, and (c) the system must be easily accessible to engineering personnel at the reactor, their offices, or any other location considered appropriate. A core operational support package developed by Westinghouse called BEACON (best estimate analysis of core operations - nuclear) has been installed at several plants. Results from these plants and numerous in-core flux maps analyzed have demonstrated the accuracy of the model and the effectiveness of the methodology

  10. Aircraft Nodal Data Acquisition System (ANDAS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Development of an Aircraft Nodal Data Acquisition System (ANDAS) based upon the short haul Zigbee networking standard is proposed. It employs a very thin (135 um)...

  11. Hybrid nodal loop metal: Unconventional magnetoresponse and material realization

    Science.gov (United States)

    Zhang, Xiaoming; Yu, Zhi-Ming; Lu, Yunhao; Sheng, Xian-Lei; Yang, Hui Ying; Yang, Shengyuan A.

    2018-03-01

    A nodal loop is formed by a band crossing along a one-dimensional closed manifold, with each point on the loop a linear nodal point in the transverse dimensions, and can be classified as type I or type II depending on the band dispersion. Here, we propose a class of nodal loops composed of both type-I and type-II points, which are hence termed as hybrid nodal loops. Based on first-principles calculations, we predict the realization of such loops in the existing electride material Ca2As . For a hybrid loop, the Fermi surface consists of coexisting electron and hole pockets that touch at isolated points for an extended range of Fermi energies, without the need for fine-tuning. This leads to unconventional magnetic responses, including the zero-field magnetic breakdown and the momentum-space Klein tunneling observable in the magnetic quantum oscillations, as well as the peculiar anisotropy in the cyclotron resonance.

  12. A nodal method based on matrix-response method

    International Nuclear Information System (INIS)

    Rocamora Junior, F.D.; Menezes, A.

    1982-01-01

    A nodal method based in the matrix-response method, is presented, and its application to spatial gradient problems, such as those that exist in fast reactors, near the core - blanket interface, is investigated. (E.G.) [pt

  13. Nodal prices determination with wind integration for radial ...

    African Journals Online (AJOL)

    With competitive electricity market operation, open access to the transmission and distribution network is essential ... The results have been obtained for IEEE 33 ...... The value of intermittent wind DG under nodal prices and amp – mile tariffs.

  14. Nodal aberration theory for wild-filed asymmetric optical systems

    Science.gov (United States)

    Chen, Yang; Cheng, Xuemin; Hao, Qun

    2016-10-01

    Nodal Aberration Theory (NAT) was used to calculate the zero field position in Full Field Display (FFD) for the given aberration term. Aiming at wide-filed non-rotational symmetric decentered optical systems, we have presented the nodal geography behavior of the family of third-order and fifth-order aberrations. Meanwhile, we have calculated the wavefront aberration expressions when one optical element in the system is tilted, which was not at the entrance pupil. By using a three-piece-cellphone lens example in optical design software CodeV, the nodal geography is testified under several situations; and the wavefront aberrations are calculated when the optical element is tilted. The properties of the nodal aberrations are analyzed by using Fringe Zernike coefficients, which are directly related with the wavefront aberration terms and usually obtained by real ray trace and wavefront surface fitting.

  15. Biomechanics of the pelvic floor musculature

    NARCIS (Netherlands)

    Janda, S.

    2006-01-01

    The present thesis was motivated by two main goals. The first research goal of the thesis was to understand the complex biomechanical behaviour of the pelvic floor muscles. The second goal was to study the mechanism of the pelvic organ prolapse (genital prolapse). The pelvic floor in humans is a

  16. Early development of the human pelvic diaphragm

    NARCIS (Netherlands)

    Koch, Wijnandus Franciscus Robertus Maria

    2006-01-01

    The last decade an increasing interest in the pelvic floor can be observed in medical sciences. The lack of data on the development of the human pelvic floor is striking. The early development of the human pelvic diaphragm was studied. Materials and methodsUse was made of 38 human embryos and

  17. Extension of the analytic nodal method to four energy groups

    International Nuclear Information System (INIS)

    Parsons, D.K.; Nigg, D.W.

    1985-01-01

    The Analytic Nodal Method is one of several recently-developed coarse mesh numerical methods for efficiently and accurately solving the multidimensional static and transient neutron diffusion equations. This summary describes a mathematically rigorous extension of the Analytic Nodal Method to the frequently more physically realistic four-group case. A few general theoretical considerations are discussed, followed by some calculated results for a typical steady-state two-dimensional PWR quarter core application. 8 refs

  18. Cecal rupture after continent ileocecal urinary diversion during total pelvic exenteration

    International Nuclear Information System (INIS)

    Brand, E.

    1991-01-01

    Continent ureteral diversion at the time of pelvic exenteration avoids an external appliance and allows patients to retain bladder reservoir function. The technical difficulty of this procedure requires meticulous attention to operative and perioperative care, particularly after pelvic irradiation. A patient with recurrent stage IIIB carcinoma of the cervix underwent total pelvic exenteration with reconstructive procedures including low rectal anastomosis, neovagina formation, and ileocecal (Indiana) continent diversion. Early catheterization of the reservoir began 2 weeks postoperatively. One week later cecal rupture occurred, not related to suture line (technical) failure. Because of the high wall tension and reduced compliance in the irradiated cecum, the authors do not recommend catheterization of the urinary reservoir before 4-6 weeks. In order for continent diversion to become the standard diversion in exenteration patients, the major complication rate must remain comparable to that of noncontinent diversion

  19. Bilinear nodal transport method in weighted diamond difference form

    International Nuclear Information System (INIS)

    Azmy, Y.Y.

    1987-01-01

    Nodal methods have been developed and implemented for the numerical solution of the discrete ordinates neutron transport equation. Numerical testing of these methods and comparison of their results to those obtained by conventional methods have established the high accuracy of nodal methods. Furthermore, it has been suggested that the linear-linear approximation is the most computationally efficient, practical nodal approximation. Indeed, this claim has been substantiated by comparing the accuracy in the solution, and the CPU time required to achieve convergence to that solution by several nodal approximations, as well as the diamond difference scheme. Two types of linear-linear nodal methods have been developed in the literature: analytic linear-linear (NLL) methods, in which the transverse-leakage terms are derived analytically, and approximate linear-linear (PLL) methods, in which these terms are approximated. In spite of their higher accuracy, NLL methods result in very complicated discrete-variable equations that exhibit a high degree of coupling, thus requiring special solution algorithms. On the other hand, the sacrificed accuracy in PLL methods is compensated for by the simple discrete-variable equations and diamond-difference-like solution algorithm. In this paper the authors outline the development of an NLL nodal method, the bilinear method, which can be written in a weighted diamond difference form with one spatial weight per dimension that is analytically derived rather than preassigned in an ad hoc fashion

  20. Uniqueness Theorem for the Inverse Aftereffect Problem and Representation the Nodal Points Form

    Directory of Open Access Journals (Sweden)

    A. Neamaty

    2015-03-01

    Full Text Available In this paper, we consider a boundary value problem with aftereffect on a finite interval. Then, the asymptotic behavior of the solutions, eigenvalues, the nodal points and the associated nodal length are studied. We also calculate the numerical values of the nodal points and the nodal length. Finally, we prove the uniqueness theorem for the inverse aftereffect problem by applying any dense subset of the nodal points.

  1. Uniqueness Theorem for the Inverse Aftereffect Problem and Representation the Nodal Points Form

    OpenAIRE

    A. Neamaty; Sh. Akbarpoor; A. Dabbaghian

    2015-01-01

    In this paper, we consider a boundary value problem with aftereffect on a finite interval. Then, the asymptotic behavior of the solutions, eigenvalues, the nodal points and the associated nodal length are studied. We also calculate the numerical values of the nodal points and the nodal length. Finally, we prove the uniqueness theorem for the inverse aftereffect problem by applying any dense subset of the nodal points.

  2. Bone Health and Pelvic Radiotherapy.

    Science.gov (United States)

    Higham, C E; Faithfull, S

    2015-11-01

    Survivors who have received pelvic radiotherapy make up many of the long-term cancer population, with therapies for gynaecological, bowel, bladder and prostate malignancies. Individuals who receive radiotherapy to the pelvis as part of their cancer treatment are at risk of insufficiency fractures. Symptoms of insufficiency fractures include pelvic and back pain and immobility, which can affect substantially quality of life. This constellation of symptoms can occur within 2 months of radiotherapy up to 63 months post-treatment, with a median incidence of 6-20 months. As a condition it is under reported and evidence is poor as to the contributing risk factors, causation and best management to improve the patient's bone health and mobility. As radiotherapy advances, chronic symptoms, such as insufficiency fractures, as a consequence of treatment need to be better understood and reviewed. This overview explores the current evidence for the effect of radiotherapy on bone health and insufficiency fractures and identifies what we know and where gaps in our knowledge lie. The overview concludes with the need to take seriously complaints of pelvic pain from patients after pelvic radiotherapy and to investigate and manage these symptoms more effectively. There is a clear need for definitive research in this field to provide the evidence-based guidance much needed in practice. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  3. Obesity and pelvic organ prolapse

    NARCIS (Netherlands)

    Lee, U.J.; Kerkhof, M.H.; Leijsen, S.A. van; Heesakkers, J.P.F.A.

    2017-01-01

    PURPOSE OF REVIEW: The purpose of this review is to review the data on the relationship of obesity and pelvic organ prolapse (POP). This review is timely and relevant as the prevalence of obesity is increasing worldwide, and it is an important risk factor to consider in counseling women on

  4. MR imaging in female pelvic organs prolapse

    International Nuclear Information System (INIS)

    Capiel, Carlos A. h; Bouzas, Carlos A.

    2003-01-01

    Pelvic floor weakness and consequent organ prolapse may result in a variety of symptoms, including pain, urinary or fecal incontinence and constipation. Diagnosis is made primary on the basis of findings at physical pelvic examination. Imaging is useful in patients in whom findings at physical examination are equivocal. Different imaging techniques (fluoroscopy, ultrasonography), can be useful in evaluating pelvic organs prolapse. MR imaging is a new noninvasive technique that provides a multiplanar global evaluation of the pelvic contents and demonstrates pelvic organs prolapse. Reference points are the pubococcygeal line and puborectalis muscle sling. This pictorial assay illustrates different grades of cystourethrocele, recto-sigmoidocele and hysteroptosis (uterine prolapse) on MR imaging. (author)

  5. Uterine carcinosarcoma associated with pelvic radiotherapy for sacral chordoma: A case report

    Directory of Open Access Journals (Sweden)

    Korhan Kahraman

    2012-03-01

    Conclusion: In uterine masses seen in patients with history of irradiation to the pelvic field, the probability of uterine sarcomas should always be kept in mind. These tumors may occur simultaneously with recurrence of primary tumor previously treated by adjuvant radiation therapy.

  6. [Functional aspects of pelvic floor surgery].

    Science.gov (United States)

    Wagenlehner, F M E; Gunnemann, A; Liedl, B; Weidner, W

    2009-11-01

    Pelvic floor dysfunctions are frequently seen in females. The human pelvic floor is a complex structure and heavily stressed throughout female life. Recent findings in the functional anatomy of the pelvic floor have led to a much better understand-ing, on the basis of which enormous improvements in the therapeutic options have arisen. The pelvic floor activity is regulated by three main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor -organs, bladder and rectum. For different reasons laxity in the vagina or its supporting ligaments as a result of altered connective tissue can distort this functional anatomy. A variety of symptoms can derive from these pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, faecal incontinence, obstructive bowel disease syndrome and pelvic pain. Pelvic floor reconstruction is nowadays driven by the concept that in the case of pelvic floor symptoms restoration of the anatomy will translate into restoration of the physiology and ultimately improve the patients' symptoms. The exact surgical reconstruction of the anatomy is there-fore almost exclusively focused on the restoration of the lax pelvic floor ligaments. An exact identification of the anatomic lesions preoperatively is eminently necessary, to allow for an exact anatomic reconstruction with respect to the muscular forces of the pelvic floor. Georg Thieme Verlag Stuttgart * New York.

  7. Mode of delivery and Pelvic floor disorder

    International Nuclear Information System (INIS)

    Noor, R.; Neelam, H.; Bashir, M.S.

    2017-01-01

    Objective: To compare pelvic floor dysfunction in non pregnant women who had delivered vaginally versus those with cesarean delivery. Methodology: The prevalence of pelvic floor disorders among non pregnant women was assesses by using a standardized tool pelvic floor distress inventory short form (PFDI-20). Data was collected from Jinnah Hospital Lahore, Pakistan. Results: Total numbers of participants were 278. 47.12% subjects had moderate, 36.69% miner and 16.19% had severe pelvic floor dysfunction. The symptoms of pelvic organ prolapse were more prevalent (mean value is 59.1876) than Urinary Distress (mean value is 40.5426), while the Colorectal-Anal Distress (mean value is 35.9150) were least prevalent. Conclusion: Pelvic floor disorders are very common among females and are strongly associated with mode of delivery. Although spontaneous vaginal birth was extensively associated with pelvic floor disorders the instrumental delivery affects most. (author)

  8. Bladder Cancer Patterns of Pelvic Failure: Implications for Adjuvant Radiation Therapy

    International Nuclear Information System (INIS)

    Baumann, Brian C.; Guzzo, Thomas J.; He Jiwei; Vaughn, David J.; Keefe, Stephen M.; Vapiwala, Neha; Deville, Curtiland; Bekelman, Justin E.; Tucker, Kai; Hwang, Wei-Ting; Malkowicz, S. Bruce; Christodouleas, John P.

    2013-01-01

    Purpose: Local-regional failures (LFs) after cystectomy with or without chemotherapy are common in locally advanced disease. Adjuvant radiation therapy (RT) could reduce LFs, but toxicity has discouraged its use. Modern RT techniques with improved normal tissue sparing have rekindled interest but require knowledge of pelvic failure patterns to design treatment volumes. Methods and Materials: Five-year LF rates after radical cystectomy plus pelvic node dissection with or without chemotherapy were determined for 8 pelvic sites among 442 urothelial bladder carcinoma patients. The impact of pathologic stage, margin status, nodal involvement, and extent of node dissection on failure patterns was assessed using competing risk analysis. We calculated the percentage of patients whose sites of LF would have been completely encompassed within various hypothetical clinical target volumes (CTVs) for postoperative radiation. Results: Compared with stage ≤pT2, stage ≥pT3 patients had higher 5-year LF rates in virtually all pelvic sites. Among stage ≥pT3 patients, margin status significantly altered the failure pattern whereas extent of node dissection and nodal positivity did not. In stage ≥pT3 patients with negative margins, failure occurred predominantly in the iliac/obturator nodes and uncommonly in the cystectomy bed and/or presacral nodes. Of these patients in whom failure subsequently occurred, 76% would have had all LF sites encompassed within CTVs covering only the iliac/obturator nodes. In stage ≥pT3 with positive margins, cystectomy bed and/or presacral nodal failures increased significantly. Only 57% of such patients had all LF sites within CTVs limited to the iliac/obturator nodes, but including the cystectomy bed and presacral nodes in the CTV when margins were positive increased the percentage of LFs encompassed to 91%. Conclusions: Patterns of failure within the pelvis are summarized to facilitate design of adjuvant RT protocols. These data suggest that

  9. Bladder Cancer Patterns of Pelvic Failure: Implications for Adjuvant Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Brian C. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Guzzo, Thomas J. [Department of Urology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); He Jiwei [Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Vaughn, David J.; Keefe, Stephen M. [Department of Medical Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Vapiwala, Neha; Deville, Curtiland; Bekelman, Justin E.; Tucker, Kai [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Hwang, Wei-Ting [Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Malkowicz, S. Bruce [Department of Urology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Christodouleas, John P., E-mail: christojo@uphs.upenn.edu [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2013-02-01

    Purpose: Local-regional failures (LFs) after cystectomy with or without chemotherapy are common in locally advanced disease. Adjuvant radiation therapy (RT) could reduce LFs, but toxicity has discouraged its use. Modern RT techniques with improved normal tissue sparing have rekindled interest but require knowledge of pelvic failure patterns to design treatment volumes. Methods and Materials: Five-year LF rates after radical cystectomy plus pelvic node dissection with or without chemotherapy were determined for 8 pelvic sites among 442 urothelial bladder carcinoma patients. The impact of pathologic stage, margin status, nodal involvement, and extent of node dissection on failure patterns was assessed using competing risk analysis. We calculated the percentage of patients whose sites of LF would have been completely encompassed within various hypothetical clinical target volumes (CTVs) for postoperative radiation. Results: Compared with stage {<=}pT2, stage {>=}pT3 patients had higher 5-year LF rates in virtually all pelvic sites. Among stage {>=}pT3 patients, margin status significantly altered the failure pattern whereas extent of node dissection and nodal positivity did not. In stage {>=}pT3 patients with negative margins, failure occurred predominantly in the iliac/obturator nodes and uncommonly in the cystectomy bed and/or presacral nodes. Of these patients in whom failure subsequently occurred, 76% would have had all LF sites encompassed within CTVs covering only the iliac/obturator nodes. In stage {>=}pT3 with positive margins, cystectomy bed and/or presacral nodal failures increased significantly. Only 57% of such patients had all LF sites within CTVs limited to the iliac/obturator nodes, but including the cystectomy bed and presacral nodes in the CTV when margins were positive increased the percentage of LFs encompassed to 91%. Conclusions: Patterns of failure within the pelvis are summarized to facilitate design of adjuvant RT protocols. These data suggest

  10. Validation of the Pelvic Floor Distress Inventory-20 and the Pelvic Floor Impact Questionnaire-7 in Danish women with pelvic organ prolapse

    DEFF Research Database (Denmark)

    Due, Ulla; Brostrøm, Søren; Lose, Gunnar

    2013-01-01

    To translate the Pelvic Floor Distress Inventory-20 (PFDI-20) and the Pelvic Floor Impact Questionnaire-7 (PFIQ-7) and to evaluate their psychometric properties in Danish women with symptomatic pelvic organ prolapse....

  11. Investigation on generalized Variational Nodal Methods for heterogeneous nodes

    International Nuclear Information System (INIS)

    Wang, Yongping; Wu, Hongchun; Li, Yunzhao; Cao, Liangzhi; Shen, Wei

    2017-01-01

    Highlights: • We developed two heterogeneous nodal methods based on the Variational Nodal Method. • Four problems were solved to evaluate the two heterogeneous nodal methods. • The function expansion method is good at treating continuous-changing heterogeneity. • The finite sub-element method is good at treating discontinuous-changing heterogeneity. - Abstract: The Variational Nodal Method (VNM) is generalized for heterogeneous nodes and applied to four kinds of problems including Molten Salt Reactor (MSR) core problem with continuous cross section profile, Pressurized Water Reactor (PWR) control rod cusping effect problem, PWR whole-core pin-by-pin problem, and heterogeneous PWR core problem without fuel-coolant homogenization in each pin cell. Two approaches have been investigated for the treatment of the nodal heterogeneity in this paper. To concentrate on spatial heterogeneity, diffusion approximation was adopted for the angular variable in neutron transport equation. To provide demonstrative numerical results, the codes in this paper were developed in slab geometry. The first method, named as function expansion (FE) method, expands nodal flux by orthogonal polynomials and the nodal cross sections are also expressed as spatial depended functions. The second path, named as finite sub-element (FS) method, takes advantage of the finite-element method by dividing each node into numbers of homogeneous sub-elements and expanding nodal flux into the combination of linear sub-element trial functions. Numerical tests have been carried out to evaluate the ability of the two nodal (coarse-mesh) heterogeneous VNMs by comparing with the fine-mesh homogeneous VNM. It has been demonstrated that both heterogeneous approaches can handle heterogeneous nodes. The FE method is good at continuous-changing heterogeneity as in the MSR core problem, while the FS method is good at discontinuous-changing heterogeneity such as the PWR pin-by-pin problem and heterogeneous PWR core

  12. Implications of inaccurate clinical nodal staging in pancreatic adenocarcinoma.

    Science.gov (United States)

    Swords, Douglas S; Firpo, Matthew A; Johnson, Kirsten M; Boucher, Kenneth M; Scaife, Courtney L; Mulvihill, Sean J

    2017-07-01

    Many patients with stage I-II pancreatic adenocarcinoma do not undergo resection. We hypothesized that (1) clinical staging underestimates nodal involvement, causing stage IIB to have a greater percent of resected patients and (2) this stage-shift causes discrepancies in observed survival. The Surveillance, Epidemiology, and End Results (SEER) research database was used to evaluate cause-specific survival in patients with pancreatic adenocarcinoma from 2004-2012. Survival was compared using the log-rank test. Single-center data on 105 patients who underwent resection of pancreatic adenocarcinoma without neoadjuvant treatment were used to compare clinical and pathologic nodal staging. In SEER data, medium-term survival in stage IIB was superior to IB and IIA, with median cause-specific survival of 14, 9, and 11 months, respectively (P < .001). Seventy-two percent of stage IIB patients underwent resection vs 28% in IB and 36% in IIA (P < .001). In our institutional data, 12.4% of patients had clinical evidence of nodal involvement vs 69.5% by pathologic staging (P < .001). Among clinical stage IA-IIA patients, 71.6% had nodal involvement by pathologic staging. Both SEER and institutional data support substantial underestimation of nodal involvement by clinical staging. This finding has implications in decisions regarding neoadjuvant therapy and analysis of outcomes in the absence of pathologic staging. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Nodal methods for problems in fluid mechanics and neutron transport

    International Nuclear Information System (INIS)

    Azmy, Y.Y.

    1985-01-01

    A new high-accuracy, coarse-mesh, nodal integral approach is developed for the efficient numerical solution of linear partial differential equations. It is shown that various special cases of this general nodal integral approach correspond to several high efficiency nodal methods developed recently for the numerical solution of neutron diffusion and neutron transport problems. The new approach is extended to the nonlinear Navier-Stokes equations of fluid mechanics; its extension to these equations leads to a new computational method, the nodal integral method which is implemented for the numerical solution of these equations. Application to several test problems demonstrates the superior computational efficiency of this new method over previously developed methods. The solutions obtained for several driven cavity problems are compared with the available experimental data and are shown to be in very good agreement with experiment. Additional comparisons also show that the coarse-mesh, nodal integral method results agree very well with the results of definitive ultra-fine-mesh, finite-difference calculations for the driven cavity problem up to fairly high Reynolds numbers

  14. [Ultrasonography in acute pelvic pain].

    Science.gov (United States)

    Kupesić, Sanja; Aksamija, Alenka; Vucić, Niksa; Tripalo, Ana; Kurjak, Asim

    2002-01-01

    Acute pelvic pain may be the manifestation of various gynecologic and non-gynecologic disorders from less alarming rupture of the follicular cyst to life threatening conditions such as rupture of ectopic pregnancy or perforation of inflamed appendix. In order to construct an algorithm for differential diagnosis we divide acute pelvic pain into gynecologic and non-gynecologic etiology, which is than subdivided into gastrointestinal and urinary causes. Appendicitis is the most common surgical emergency and should always be considered in differential diagnosis if appendix has not been removed. Apart of clinical examination and laboratory tests, an ultrasound examination is sensitive up to 90% and specific up to 95% if graded compression technique is used. Still it is user-depended and requires considerable experience in order to perform it reliably. Meckel's diverticulitis, acute terminal ileitis, mesenteric lymphadenitis and functional bowel disease are conditions that should be differentiated from other causes of low abdominal pain by clinical presentation, laboratory and imaging tests. Dilatation of renal pelvis and ureter are typical signs of obstructive uropathy and may be efficiently detected by ultrasound. Additional thinning of renal parenchyma suggests long-term obstructive uropathy. Ruptured ectopic pregnancy, salpingitis and hemorrhagic ovarian cysts are three most commonly diagnosed gynecologic conditions presenting as an acute abdomen. Degenerating leiomyomas and adnexal torsion occur less frequently. For better systematization, gynecologic causes of acute pelvic pain could be divided into conditions with negative pregnancy test and conditions with positive pregnancy test. Pelvic inflammatory disease may be ultrasonically presented with numerous signs such as thickening of the tubal wall, incomplete septa within the dilated tube, demonstration of hyperechoic mural nodules, free fluid in the "cul-de-sac" etc. Color Doppler ultrasound contributes to more

  15. Pelvic morphology in ischiofemoral impingement

    International Nuclear Information System (INIS)

    Bredella, Miriam A.; Azevedo, Debora C.; Oliveira, Adriana L.; Simeone, Frank J.; Chang, Connie Y.; Torriani, Martin; Stubbs, Allston J.

    2015-01-01

    To assess MRI measures to quantify pelvic morphology that may predispose to ischiofemoral impingement (IFI). We hypothesized that patients with IFI have a wider interischial distance and an increased femoral neck angle compared with normal controls. The study was IRB-approved and complied with HIPAA guidelines. IFI was diagnosed based on clinical findings (hip or buttock pain) and ipsilateral edema of the quadratus femoris muscle on MRI. Control subjects did not report isolated hip/buttock pain and underwent MRI for surveillance of neoplasms or to exclude pelvic fractures. Two MSK radiologists measured the ischiofemoral (IF) and quadratus femoris (QF) distance, the ischial angle as a measure of inter-ischial distance, and the femoral neck angle. The quadratus femoris muscle was evaluated for edema. Groups were compared using ANOVA. Multivariate standard least-squares regression modeling was used to control for age and gender. The study group comprised 84 patients with IFI (53 ± 16 years, 73 female, 11 male) and 51 controls (52 ± 16 years, 33 female, 18 male). Thirteen out of 84 patients (15 %) had bilateral IFI. Patients with IFI had decreased IF and QF distance (p < 0.0001), increased ischial angle (p = 0.004), and increased femoral neck angle (p = 0.02) compared with controls, independent of age and gender. Patients with IFI have increased ischial and femoral neck angles compared with controls. These anatomical variations in pelvic morphology may predispose to IFI. MRI is a useful method of not only assessing the osseous and soft-tissue abnormalities associated with IFI, but also of quantifying anatomical variations in pelvic morphology that can predispose to IFI. (orig.)

  16. Pelvic morphology in ischiofemoral impingement

    Energy Technology Data Exchange (ETDEWEB)

    Bredella, Miriam A.; Azevedo, Debora C.; Oliveira, Adriana L.; Simeone, Frank J.; Chang, Connie Y.; Torriani, Martin [Massachusetts General Hospital, Department of Radiology, Musculoskeletal Imaging and Intervention, Boston, MA (United States); Stubbs, Allston J. [Wake Forest University School of Medicine, Department of Orthopedic Surgery, Division of Sports Medicine, Winston-Salem, NC (United States)

    2014-11-06

    To assess MRI measures to quantify pelvic morphology that may predispose to ischiofemoral impingement (IFI). We hypothesized that patients with IFI have a wider interischial distance and an increased femoral neck angle compared with normal controls. The study was IRB-approved and complied with HIPAA guidelines. IFI was diagnosed based on clinical findings (hip or buttock pain) and ipsilateral edema of the quadratus femoris muscle on MRI. Control subjects did not report isolated hip/buttock pain and underwent MRI for surveillance of neoplasms or to exclude pelvic fractures. Two MSK radiologists measured the ischiofemoral (IF) and quadratus femoris (QF) distance, the ischial angle as a measure of inter-ischial distance, and the femoral neck angle. The quadratus femoris muscle was evaluated for edema. Groups were compared using ANOVA. Multivariate standard least-squares regression modeling was used to control for age and gender. The study group comprised 84 patients with IFI (53 ± 16 years, 73 female, 11 male) and 51 controls (52 ± 16 years, 33 female, 18 male). Thirteen out of 84 patients (15 %) had bilateral IFI. Patients with IFI had decreased IF and QF distance (p < 0.0001), increased ischial angle (p = 0.004), and increased femoral neck angle (p = 0.02) compared with controls, independent of age and gender. Patients with IFI have increased ischial and femoral neck angles compared with controls. These anatomical variations in pelvic morphology may predispose to IFI. MRI is a useful method of not only assessing the osseous and soft-tissue abnormalities associated with IFI, but also of quantifying anatomical variations in pelvic morphology that can predispose to IFI. (orig.)

  17. Analytic function expansion nodal method for nuclear reactor core design

    International Nuclear Information System (INIS)

    Noh, Hae Man

    1995-02-01

    In most advanced nodal methods the transverse integration is commonly used to reduce the multi-dimensional diffusion equation into equivalent one- dimensional diffusion equations when derving the nodal coupling equations. But the use of the transverse integration results in some limitations. The first limitation is that the transverse leakage term which appears in the transverse integration procedure must be appropriately approximated. The second limitation is that the one-dimensional flux shapes in each spatial direction resulted from the nodal calculation are not accurate enough to be directly used in reconstructing the pinwise flux distributions. Finally the transverse leakage defined for a non-rectangular node such as a hexagonal node or a triangular node is too complicated to be easily handled and may contain non-physical singular terms of step-function and delta-function types. In this thesis, the Analytic Function Expansion Nodal (AFEN) method and its two variations : the Polynomial Expansion Nodal (PEN) method and the hybrid of the AFEN and PEN methods, have been developed to overcome the limitations of the transverse integration procedure. All of the methods solve the multidimensional diffusion equation without the transverse integration. The AFEN method which we believe is the major contribution of this study to the reactor core analysis expands the homogeneous flux distributions within a node in non-separable analytic basis functions satisfying the neutron diffusion equations at any point of the node and expresses the coefficients of the flux expansion in terms of the nodal unknowns which comprise a node-average flux, node-interface fluxes, and corner-point fluxes. Then, the nodal coupling equations composed of the neutron balance equations, the interface current continuity equations, and the corner-point leakage balance equations are solved iteratively to determine all the nodal unknowns. Since the AFEN method does not use the transverse integration in

  18. On the Nodal Lines of Eisenstein Series on Schottky Surfaces

    Science.gov (United States)

    Jakobson, Dmitry; Naud, Frédéric

    2017-04-01

    On convex co-compact hyperbolic surfaces {X=Γ backslash H2}, we investigate the behavior of nodal curves of real valued Eisenstein series {F_λ(z,ξ)}, where {λ} is the spectral parameter, {ξ} the direction at infinity. Eisenstein series are (non-{L^2}) eigenfunctions of the Laplacian {Δ_X} satisfying {Δ_X F_λ=(1/4+λ^2)F_λ}. As {λ} goes to infinity (the high energy limit), we show that, for generic {ξ}, the number of intersections of nodal lines with any compact segment of geodesic grows like {λ}, up to multiplicative constants. Applications to the number of nodal domains inside the convex core of the surface are then derived.

  19. A computational study of nodal-based tetrahedral element behavior.

    Energy Technology Data Exchange (ETDEWEB)

    Gullerud, Arne S.

    2010-09-01

    This report explores the behavior of nodal-based tetrahedral elements on six sample problems, and compares their solution to that of a corresponding hexahedral mesh. The problems demonstrate that while certain aspects of the solution field for the nodal-based tetrahedrons provide good quality results, the pressure field tends to be of poor quality. Results appear to be strongly affected by the connectivity of the tetrahedral elements. Simulations that rely on the pressure field, such as those which use material models that are dependent on the pressure (e.g. equation-of-state models), can generate erroneous results. Remeshing can also be strongly affected by these issues. The nodal-based test elements as they currently stand need to be used with caution to ensure that their numerical deficiencies do not adversely affect critical values of interest.

  20. A theoretical study on a convergence problem of nodal methods

    Energy Technology Data Exchange (ETDEWEB)

    Shaohong, Z.; Ziyong, L. [Shanghai Jiao Tong Univ., 1954 Hua Shan Road, Shanghai, 200030 (China); Chao, Y. A. [Westinghouse Electric Company, P. O. Box 355, Pittsburgh, PA 15230-0355 (United States)

    2006-07-01

    The effectiveness of modern nodal methods is largely due to its use of the information from the analytical flux solution inside a homogeneous node. As a result, the nodal coupling coefficients depend explicitly or implicitly on the evolving Eigen-value of a problem during its solution iteration process. This poses an inherently non-linear matrix Eigen-value iteration problem. This paper points out analytically that, whenever the half wave length of an evolving node interior analytic solution becomes smaller than the size of that node, this non-linear iteration problem can become inherently unstable and theoretically can always be non-convergent or converge to higher order harmonics. This phenomenon is confirmed, demonstrated and analyzed via the simplest 1-D problem solved by the simplest analytic nodal method, the Analytic Coarse Mesh Finite Difference (ACMFD, [1]) method. (authors)

  1. [Multiple non-responding ESWL lithiasis in ectopic pelvic kidney: laparotomic surgical management].

    Science.gov (United States)

    Abed El Rahman, D; Zanetti, G; Cozzi, G; Cozzi, L A; Abed El Rahman, S; Maggioni, A; Rocco, F

    2010-01-01

    A 34 year-old male with multiple lithiasis of ectopic pelvic left kidney, which for 5 years had been causing pain in the left iliac region irradiating to ipsilateral inguinal region and testis. 4 ESWL treatments were unsuccessful. The diagnostic imaging (Angio-CT + Uro-CT) showed ectopic pelvic left kidney with abnormal vascularisation, characterised by multiple lithiasis extending in total area of 4x2 cm with shorter ureter. Right kidney was in normal position. A left pyelocalicolithotomy after DJ stent positioning was performed.

  2. Super-nodal methods for space-time kinetics

    Science.gov (United States)

    Mertyurek, Ugur

    The purpose of this research has been to develop an advanced Super-Nodal method to reduce the run time of 3-D core neutronics models, such as in the NESTLE reactor core simulator and FORMOSA nuclear fuel management optimization codes. Computational performance of the neutronics model is increased by reducing the number of spatial nodes used in the core modeling. However, as the number of spatial nodes decreases, the error in the solution increases. The Super-Nodal method reduces the error associated with the use of coarse nodes in the analyses by providing a new set of cross sections and ADFs (Assembly Discontinuity Factors) for the new nodalization. These so called homogenization parameters are obtained by employing consistent collapsing technique. During this research a new type of singularity, namely "fundamental mode singularity", is addressed in the ANM (Analytical Nodal Method) solution. The "Coordinate Shifting" approach is developed as a method to address this singularity. Also, the "Buckling Shifting" approach is developed as an alternative and more accurate method to address the zero buckling singularity, which is a more common and well known singularity problem in the ANM solution. In the course of addressing the treatment of these singularities, an effort was made to provide better and more robust results from the Super-Nodal method by developing several new methods for determining the transverse leakage and collapsed diffusion coefficient, which generally are the two main approximations in the ANM methodology. Unfortunately, the proposed new transverse leakage and diffusion coefficient approximations failed to provide a consistent improvement to the current methodology. However, improvement in the Super-Nodal solution is achieved by updating the homogenization parameters at several time points during a transient. The update is achieved by employing a refinement technique similar to pin-power reconstruction. A simple error analysis based on the relative

  3. A comparison of Nodal methods in neutron diffusion calculations

    Energy Technology Data Exchange (ETDEWEB)

    Tavron, Barak [Israel Electric Company, Haifa (Israel) Nuclear Engineering Dept. Research and Development Div.

    1996-12-01

    The nuclear engineering department at IEC uses in the reactor analysis three neutron diffusion codes based on nodal methods. The codes, GNOMERl, ADMARC2 and NOXER3 solve the neutron diffusion equation to obtain flux and power distributions in the core. The resulting flux distributions are used for the furl cycle analysis and for fuel reload optimization. This work presents a comparison of the various nodal methods employed in the above codes. Nodal methods (also called Coarse-mesh methods) have been designed to solve problems that contain relatively coarse areas of homogeneous composition. In the nodal method parts of the equation that present the state in the homogeneous area are solved analytically while, according to various assumptions and continuity requirements, a general solution is sought out. Thus efficiency of the method for this kind of problems, is very high compared with the finite element and finite difference methods. On the other hand, using this method one can get only approximate information about the node vicinity (or coarse-mesh area, usually a feel assembly of a 20 cm size). These characteristics of the nodal method make it suitable for feel cycle analysis and reload optimization. This analysis requires many subsequent calculations of the flux and power distributions for the feel assemblies while there is no need for detailed distribution within the assembly. For obtaining detailed distribution within the assembly methods of power reconstruction may be applied. However homogenization of feel assembly properties, required for the nodal method, may cause difficulties when applied to fuel assemblies with many absorber rods, due to exciting strong neutron properties heterogeneity within the assembly. (author).

  4. Nodal spectrum method for solving neutron diffusion equation

    International Nuclear Information System (INIS)

    Sanchez, D.; Garcia, C. R.; Barros, R. C. de; Milian, D.E.

    1999-01-01

    Presented here is a new numerical nodal method for solving static multidimensional neutron diffusion equation in rectangular geometry. Our method is based on a spectral analysis of the nodal diffusion equations. These equations are obtained by integrating the diffusion equation in X, Y directions and then considering flat approximations for the current. These flat approximations are the only approximations that are considered in this method, as a result the numerical solutions are completely free from truncation errors. We show numerical results to illustrate the methods accuracy for coarse mesh calculations

  5. Oddness of least energy nodal solutions on radial domains

    Directory of Open Access Journals (Sweden)

    Christopher Grumiau

    2010-07-01

    Full Text Available In this article, we consider the Lane-Emden problem $$displaylines{ Delta u(x + |{u(x}mathclose|^{p-2}u(x=0, quad hbox{for } xinOmega,cr u(x=0, quad hbox{for } xinpartialOmega, }$$ where $2 < p < 2^{*}$ and $Omega$ is a ball or an annulus in $mathbb{R}^{N}$, $Ngeq 2$. We show that, for p close to 2, least energy nodal solutions are odd with respect to an hyperplane -- which is their nodal surface. The proof ingredients are a constrained implicit function theorem and the fact that the second eigenvalue is simple up to rotations.

  6. Development and validation of a nodal code for core calculation

    International Nuclear Information System (INIS)

    Nowakowski, Pedro Mariano

    2004-01-01

    The code RHENO solves the multigroup three-dimensional diffusion equation using a nodal method of polynomial expansion.A comparative study has been made between this code and present internationals nodal diffusion codes, resulting that the RHENO is up to date.The RHENO has been integrated to a calculation line and has been extend to make burnup calculations.Two methods for pin power reconstruction were developed: modulation and imbedded. The modulation method has been implemented in a program, while the implementation of the imbedded method will be concluded shortly.The validation carried out (that includes experimental data of a MPR) show very good results and calculation efficiency

  7. Nodal algorithm derived from a new variational principle

    International Nuclear Information System (INIS)

    Watson, Fernando V.

    1995-01-01

    As a by-product of the research being carried on by the author on methods of recovering pin power distribution of PWR cores, a nodal algorithm based on a modified variational principle for the two group diffusion equations has been obtained. The main feature of the new algorithm is the low dimensionality achieved by the reduction of the original diffusion equations to a system of algebraic Eigen equations involving the average sources only, instead of sources and interface group currents used in conventional nodal methods. The advantage of this procedure is discussed and results generated by the new algorithm and by a finite difference code are compared. (author). 2 refs, 7 tabs

  8. Nodal approximations in space and time for neutron kinetics

    International Nuclear Information System (INIS)

    Grossman, L.M.; Hennart, J.P.

    2005-01-01

    A general formalism is described of the nodal type in time and space for the neutron kinetics equations. In space, several nodal methods are given of the Raviart-Thomas type (RT0 and RT1), of the Brezzi-Douglas-Marini type (BDM0 and BDM1) and of the Brezzi-Douglas-Fortin-Marini type (BDFM 1). In time, polynomial and analytical approximations are derived. In the analytical case, they are based on the inclusion of an exponential term in the basis function. They can be continuous or discontinuous in time, leading in particular to the well-known Crank-Nicolson, Backward Euler and θ schemes

  9. Discontinuous nodal schemes applied to the bidimensional neutron transport equation

    International Nuclear Information System (INIS)

    Delfin L, A.; Valle G, E. Del; Hennart B, J.P.

    1996-01-01

    In this paper several strong discontinuous nodal schemes are described, starting from the one that has only two interpolation parameters per cell to the one having ten. Their application to the spatial discretization of the neutron transport equation in X-Y geometry is also described, giving, for each one of the nodal schemes, the approximation for the angular neutron flux that includes the set of interpolation parameters and the corresponding polynomial space. Numerical results were obtained for several test problems presenting here the problem with the highest degree of difficulty and their comparison with published results 1,2 . (Author)

  10. Intra-abdominal gout mimicking pelvic abscess

    International Nuclear Information System (INIS)

    Chen, Chia-Hui; Chen, Clement Kuen-Huang; Yeh, Lee-Ren; Pan, Huay-Ban; Yang, Chien-Fang

    2005-01-01

    Gout is the most common crystal-induced arthritis. Gouty tophi typically deposit in the extremities, especially toes and fingers. We present an unusual case of intrapelvic tophaceous gout in a patient suffering from chronic gouty arthritis. CT and MRI of the abdomen and pelvic cavity disclosed calcified gouty tophi around both hips, and a cystic lesion with peripheral enhancement in the pelvic cavity along the course of the iliopsoas muscle. The intra-abdominal tophus mimicked pelvic abscess. (orig.)

  11. Intra-abdominal gout mimicking pelvic abscess

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chia-Hui; Chen, Clement Kuen-Huang [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (Taiwan); National Yang-Ming University, School of Medicine, Taipei (Taiwan); Yeh, Lee-Ren; Pan, Huay-Ban; Yang, Chien-Fang [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (Taiwan)

    2005-04-01

    Gout is the most common crystal-induced arthritis. Gouty tophi typically deposit in the extremities, especially toes and fingers. We present an unusual case of intrapelvic tophaceous gout in a patient suffering from chronic gouty arthritis. CT and MRI of the abdomen and pelvic cavity disclosed calcified gouty tophi around both hips, and a cystic lesion with peripheral enhancement in the pelvic cavity along the course of the iliopsoas muscle. The intra-abdominal tophus mimicked pelvic abscess. (orig.)

  12. Gynecological pelvic pain as emergency pathology.

    Science.gov (United States)

    Rivera Domínguez, A; Mora Jurado, A; García de la Oliva, A; de Araujo Martins-Romeo, D; Cueto Álvarez, L

    Acute pelvic pain is a common condition in emergency. The sources of acute pelvic pain are multifactorial, so it is important to be familiar with this type of pathologies. The purpose of this article is review the main causes of gynecological acute pelvic pain and their radiologic appearances to be able to make an accurate diagnosis and provide objective criteria for patient management. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Preoperative irradiation, lymphadenectomy, and 125iodine implantation for patients with localized carcinoma of the prostate

    International Nuclear Information System (INIS)

    DeLaney, T.F.; Shipley, W.U.; O'Leary, M.P.; Biggs, P.J.; Prout, G.R. Jr.

    1986-01-01

    Fifty-four patients with clinically and surgically localized prostatic carcinoma were treated with low-dose preoperative irradiation (1050 cGy), pelvic lymphadenectomy, and interstitial 125 Iodine implantation. The follow-up range is 2 to 9 years with a median follow-up of 5 years. Overall local tumor control is 92%. Actuarial 5-year survival is 86% and the actuarial disease-free survival at 5 years is 73%. Patients with poorly differentiated tumors have a significantly worse actuarial survival (62%) at 5 years than patients with well (95%) or moderately well differentiated tumors (93%), p = 0.04. Disease-free survival at 5 years was influenced by grade: well (100%), moderate (60%), and poor (48%), p = 0.03. Multivariate regression analysis indicates that only the degree of differentiation (p = 0.05) significantly impacts on survival. Both degree of differentiation (p = 0.04) and nodal status (p = 0.03) significantly influence disease-free survival. Potency has been maintained in 71% of patients potent at the time of implantation. Late reactions have been acceptable to date: bladder outlet obstruction (13%), mild proctitis (13%), cystourethritis (6%), incontinence (2%), and prostatic calculi (2%)

  14. Magnetic resonance imaging of pelvic floor dysfunction.

    Science.gov (United States)

    Lalwani, Neeraj; Moshiri, Mariam; Lee, Jean H; Bhargava, Puneet; Dighe, Manjiri K

    2013-11-01

    Pelvic floor dysfunction is largely a complex problem of multiparous and postmenopausal women and is associated with pelvic floor or organ descent. Physical examination can underestimate the extent of the dysfunction and misdiagnose the disorders. Functional magnetic resonance (MR) imaging is emerging as a promising tool to evaluate the dynamics of the pelvic floor and use for surgical triage and operative planning. This article reviews the anatomy and pathology of pelvic floor dysfunction, typical imaging findings, and the current role of functional MR imaging. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Contribution of pelvic floor muscles to stiffness of the pelvic ring

    NARCIS (Netherlands)

    Pool-Goudzwaard, A.L.; Hoek van Dijke, G; van Gurp, M; Mulder, P; Snijders, C.J.; Stoeckart, R.

    2004-01-01

    STUDY DESIGN: A biomechanical study in embalmed specimens, on the relation between applied tension in the pelvic floor muscles, stiffness of the pelvic ring and generation of movement in the sacroiliac joints. OBJECTIVE: To gain insight into the effect of tension in the pelvic floor muscles on

  16. Assessment of pelvic floor dysfunctions using dynamic magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Hoda Salah Darwish

    2014-03-01

    Conclusion: Dynamic MRI is an ideal, non invasive technique which does not require patient preparation for evaluation of pelvic floor. It acts as one stop shop for diagnosing single or multiple pelvic compartment involvement in patients with pelvic floor dysfunction.

  17. Retrospective review of pelvic malignancies undergoing total pelvic exenteration

    Directory of Open Access Journals (Sweden)

    Kuhrt Maureen P

    2012-06-01

    Full Text Available Abstract Background In patients with locally advanced or recurrent pelvic malignancies, total pelvic exenteration (TPE may be necessary for curative treatment. Despite improvements in mortality rates since TPE was first described, morbidity rates remain high due to the extensive resection and the aggressiveness of these tumors. We have studied the outcomes of TPE surgery performed at our institution. Methods Fifty-three patients with various pelvic pathologies underwent TPE between 2004 and 2010. Patients were divided into two groups based on pathology: colorectal (n = 36 versus non-colorectal (n = 17 malignancies. Demographics, operative reports, pathology reports, periprocedural events, and outcomes were analyzed. Comparison of the two groups was performed using student’s t-test and Fisher’s exact test. Survival curves were constructed using the Kaplan–Meier method and compared using the log rank test. Results The colorectal and non-colorectal groups were similar in demographics, operative times, length of stay, estimated blood loss, and rates of preoperative and intraoperative radiation use. Chemotherapy use was increased in the colorectal group compared with the non-colorectal group (55.6% vs. 23.5%, P = 0.04. Complication rates were similar: 86% in the colorectal group and 76% in the non-colorectal group. In the colorectal group, 27.8% of patients developed perineal abscesses, whereas no patients developed these complications in the non-colorectal group (P = 0.02. No survival difference was seen in primary versus recurrent colorectal tumors; however, within the colorectal group there was a survival advantage when comparing R0 resection to R1 and R2 resection combined. Median survival rates were 27.3 months for R0 resection and 10.7 months for R1 and R2 resection combined. The median survival was 21.4 months for the colorectal group and 6.9 months for the non-colorectal group (P = 0.002. Conclusions

  18. Extension of the linear nodal method to large concrete building calculations

    International Nuclear Information System (INIS)

    Childs, R.L.; Rhoades, W.A.

    1985-01-01

    The implementation of the linear nodal method in the TORT code is described, and the results of a mesh refinement study to test the effectiveness of the linear nodal and weighted diamond difference methods available in TORT are presented

  19. The Nodal Location of Metastases in Melanoma Sentinel Lymph Nodes

    DEFF Research Database (Denmark)

    Riber-Hansen, Rikke; Nyengaard, Jens; Hamilton-Dutoit, Stephen

    2009-01-01

    BACKGROUND: The design of melanoma sentinel lymph node (SLN) histologic protocols is based on the premise that most metastases are found in the central parts of the nodes, but the evidence for this belief has never been thoroughly tested. METHODS: The nodal location of melanoma metastases in 149...

  20. Real-time control of power systems using nodal prices

    NARCIS (Netherlands)

    Jokic, A.; Lazar, M.; Bosch, van den P.P.J.

    2009-01-01

    This article presents a novel control scheme for achieving optimal power balancing and congestion management in electrical power systems via nodal prices. We develop a dynamic controller that guarantees economically optimal steady-state operation while respecting all line flow constraints in

  1. Topological transport in Dirac nodal-line semimetals

    Science.gov (United States)

    Rui, W. B.; Zhao, Y. X.; Schnyder, Andreas P.

    2018-04-01

    Topological nodal-line semimetals are characterized by one-dimensional Dirac nodal rings that are protected by the combined symmetry of inversion P and time-reversal T . The stability of these Dirac rings is guaranteed by a quantized ±π Berry phase and their low-energy physics is described by a one-parameter family of (2+1)-dimensional quantum field theories exhibiting the parity anomaly. Here we study the Berry-phase supported topological transport of P T -invariant nodal-line semimetals. We find that small inversion breaking allows for an electric-field-induced anomalous transverse current, whose universal component originates from the parity anomaly. Due to this Hall-like current, carriers at opposite sides of the Dirac nodal ring flow to opposite surfaces when an electric field is applied. To detect the topological currents, we propose a dumbbell device, which uses surface states to filter charges based on their momenta. Suggestions for experiments and device applications are discussed.

  2. Hyoid bone chondrosarcoma with cervical nodal metastasis: A case ...

    African Journals Online (AJOL)

    Background: Hyoid bone chondrosarcoma is a very rare condition. This study presents a case report of low-grade chondrosarcoma of hyoid bone with cervical nodal metastasis. The study also presents preoperative radiological investigations, pathological examination and the follow-up of the case. Case presentation: A 42 ...

  3. Note on the nodal line of the p-Laplacian

    Directory of Open Access Journals (Sweden)

    Abdel R. El Amrouss

    2006-09-01

    Full Text Available In this paper, we prove that the length of the nodal line of the eigenfunctions associated to the second eigenvalue of the problem $$ -Delta_p u = lambda ho (x |u|^{p-2}u quad hbox{in } Omega $$ with the Dirichlet conditions is not bounded uniformly with respect to the weight.

  4. A nodal method based on the response-matrix method

    International Nuclear Information System (INIS)

    Cunha Menezes Filho, A. da; Rocamora Junior, F.D.

    1983-02-01

    A nodal approach based on the Response-Matrix method is presented with the purpose of investigating the possibility of mixing two different allocations in the same problem. It is found that the use of allocation of albedo combined with allocation of direct reflection produces good results for homogeneous fast reactor configurations. (Author) [pt

  5. CRY 1AB trangenic cowpea obtained by nodal electroporation ...

    African Journals Online (AJOL)

    Electroporation-mediated genetic transformation was used to introduce Cry 1 Ab insecticidal gene into cowpea. Nodal buds were electroporated in planta with a plasmid carrying the Cry 1Ab and antibiotic resistance npt II genes driven by a 35S CaMV promoter. T1 seeds derived from electroporated branches were selected ...

  6. Reconstructive options in pelvic tumours

    Directory of Open Access Journals (Sweden)

    Mayilvahanan N

    2005-01-01

    Full Text Available Background: Pelvic tumours present a complex problem. It is difficult to choose between limb salvage and hemipelvectomy. Method: Forty three patients of tumours of pelvis underwent limb salvage resection with reconstruction in 32 patients. The majority were chondrosarcomas (20 cases followed by Ewing sarcoma. Stage II B was the most common stage in malignant lesions and all the seven benign lesions were aggressive (B3. Surgical margins achieved were wide in 31 and marginal in 12 cases. Ilium was involved in 51% of cases and periacetabular involvement was seen in 12 patients. The resections done were mostly of types I &II of Enneking′s classification of pelvic resection. Arthrodesis was attempted in 24 patients. Customized Saddle prosthesis was used in seven patients and no reconstruction in 12 patients. Adjuvant chemotherapy was given to all high-grade malignant tumours, combined with radiotherapy in 7 patients. Results: With a mean follow up of 48.5 months and one patient lost to follow up, the recurrence rate among the evaluated cases was 16.6%. Oncologically, 30 patients were continuously disease free with 7 local recurrences and 4 deaths due to disseminated disease and 2 patients died of other causes. During the initial years, satisfactory functional results were achieved with prosthetic replacement. Long-term functional result of 36 patients who were alive at the time of latest follow up was satisfactory in 75% who underwent arthrodesis and in those where no reconstruction was used. We also describe a method of new classification of pelvic resections that clarifies certain shortcomings of the previous systems of classification. Conclusion: Selection of a procedure depends largely on the patient factors, the tumour grade, the resultant defect and the tissue factors. Resection with proper margins gives better functional and oncological results

  7. Pentoxifylline in the treatment of radiation-related pelvic insufficiency fractures of bone

    International Nuclear Information System (INIS)

    Bese, N.S.; Oezgueroglu, M.; Kamberoglu, K.; Karahasanoglu, T.; Oeber, A.

    2003-01-01

    The reported incidence of bone complications after radiation therapy is quite low. The most commonly seen bone complication is insufficiency fractures of the pubis and sacrum. Treatment of insufficiency fractures consists of conservative care, and mineral replacement may be useful. The resolution of symptoms takes at least one year with these treatments. Vascular damage has an important role in the etiology of late radiation injury in normal tissues. Progressive ischemic changes further weaken the bone structure, which can cause fractures, and healing is also delayed. Pentoxifylline is a methylxanthine derivative that is shown to increase tissue blood flow. Here, we present a 63-year-old male patient with pelvic insufficiency fractures due to postoperative pelvic irradiation for rectal adenocarcinoma. The patient received pelvic radiotherapy to a total dose of 50.4 Gy with concomitant 5-FU. Six months after the completion of radiotherapy, the patient presented with severe pelvic pain. Pelvic magnetic resonance imaging (MRI) demonstrated abnormal signal intensity with insufficiency fractures at the sacrum and bone marrow edema near the fractures, but not an abnormal intensity that revealed bone metastases. Neither distant nor locoregional recurrence was observed at his work-up. The final diagnosis was insufficiency fractures of the pelvic bones owing to irradiation, and pentoxifylline (400 mg, 3 times daily, peroral, 1,200 mg/day) was used for eight months as treatment. Dramatic clinical improvement was obtained in six months, and objective healing was revealed with MRI. We concluded that pentoxifylline is a cost-effective drug with minimal adverse effects in treating radiation damage of bone. (author)

  8. 47 CFR 101.503 - Digital Electronic Message Service Nodal Stations.

    Science.gov (United States)

    2010-10-01

    ... Service § 101.503 Digital Electronic Message Service Nodal Stations. 10.6 GHz DEMS Nodal Stations may be... 47 Telecommunication 5 2010-10-01 2010-10-01 false Digital Electronic Message Service Nodal Stations. 101.503 Section 101.503 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY...

  9. Assessment of a semiautomated pelvic floor measurement model for evaluating pelvic organ prolapse on MRI.

    Science.gov (United States)

    Onal, S; Lai-Yuen, S; Bao, P; Weitzenfeld, A; Greene, K; Kedar, R; Hart, S

    2014-06-01

    The objective of this study was to assess the performance of a semiautomated pelvic floor measurement algorithmic model on dynamic magnetic resonance imaging (MRI) images compared with manual pelvic floor measurements for pelvic organ prolapse (POP) evaluation. We examined 15 MRIs along the midsagittal view. Five reference points used for pelvic floor measurements were identified both manually and using our semiautomated measurement model. The two processes were compared in terms of accuracy and precision. The semiautomated pelvic floor measurement model provided highly consistent and accurate locations for all reference points on MRI. Results also showed that the model can identify the reference points faster than the manual-point identification process. The semiautomated pelvic floor measurement model can be used to facilitate and improve the process of pelvic floor measurements on MRI. This will enable high throughput analysis of MRI data to improve the correlation analysis with clinical outcomes and potentially improve POP assessment.

  10. Laparoscopic Pelvic Floor Repair Using Polypropylene Mesh

    Directory of Open Access Journals (Sweden)

    Shih-Shien Weng

    2008-09-01

    Conclusion: Laparoscopic pelvic floor repair using a single piece of polypropylene mesh combined with uterosacral ligament suspension appears to be a feasible procedure for the treatment of advanced vaginal vault prolapse and enterocele. Fewer mesh erosions and postoperative pain syndromes were seen in patients who had no previous pelvic floor reconstructive surgery.

  11. 38 CFR 4.67 - Pelvic bones.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Pelvic bones. 4.67 Section 4.67 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.67 Pelvic bones. The variability of residuals...

  12. Biomimetic matrices for pelvic floor repair

    NARCIS (Netherlands)

    Vashaghian, M.

    2017-01-01

    Pelvic organ prolapsed (POP) is a dysfunctional disease in female pelvic floor that affects a lot of women worldwide, and reduces their quality of life. Currently, trans-vaginal knitted polypropylene meshes are used as secondary treatment, for anatomical correction of the dysfunctional tissues.

  13. The screening pelvic radiograph in pediatric trauma

    International Nuclear Information System (INIS)

    Rees, M.J.; Aickin, R.; Kolbe, A.; Teele, R.L.

    2001-01-01

    Background. Pelvic radiographs are routinely obtained in adult trauma to optimise early management. In adults, pelvic fractures are associated with high early transfusion requirement, high injury severity scores and an increased incidence of other abdominal and thoracic injuries. It is unclear whether this holds true in children. Objective. To determine whether the screening pelvic radiograph is necessary in paediatric trauma. Materials and methods. The notes of all patients who presented after trauma to the Starship Children's Hospital and were triaged to the resuscitation room during 1997 were reviewed. Results of initial radiography were obtained and correlated with later imaging. Results. Our review of 444 injured children seen over a period of 1 year revealed that of 347 children who had screening pelvic radiographs, only 1 had a pelvic fracture. The fracture in this child was clinically apparent and required no specific treatment. Conclusions. The presence of a pelvic fracture is rare in injured children. By omitting screening pelvic radiographs there are potential benefits, including reduced radiation exposure to children and cost savings. Uninterpretable or abnormal clinical examination or haematuria requires further investigation, but routine screening for pelvic fracture is unnecessary. (orig.)

  14. MANAGEMENT OF PELVIC FRACTURES IN DOG

    African Journals Online (AJOL)

    EDITOR-IN-CHIEF

    Dept. of Surgery and Radiology, College of Veterinary Science and Animal Husbandry,. Birsa Agricultural ... dogs, most of the pelvic fractures recover without surgery. .... management in the dog and cat,. New York: Thieme, pp. 161-199. FOSSUM, T.W. (2007) Pelvic fractures. In: Fossum, T.W., 3rd edn.Small. Animal Surgery.

  15. Prophylactic irradiation of para-aortic lymph nodes in carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Chatani, M.; Matayoshi, Y.; Masaki, N.; Narumi, Y.; Teshima, T.; Inoue, T.

    1995-01-01

    For assessment of the advantages and side effects of para-aortic lymph nodes irradiation under the evaluation by computer tomography, a prospective randomized study was started in 1986. The results for survival, local control and late complications are presented in the following. From November 1986 to October 1990, 93 patients with cervical carcinoma were randomly allocated for treatment with either pelvic irradiation (pelvic group) or pelvic plus para-aortic lymph nodes irradiation (para-aortic group). Thirty-six patients underwent external irradiation and intracavitary therapy (RT arm) and 57 patients, extended radical hysterectomy and external irradiation (OP-RT arm). Para-aortic lymph nodes irradiation delivered 45 Gy in 1.8 Gy per day for 5 days per week through anterior-posterior fields. The 3-year cause specific survival rates were para-aortic group: 57% and pelvic group: 89% in RT arm group, and para-aortic group: 70% and pelvic group: 86% in OP-RT arm group. Differences for the 2 groups in each treatment arm were not significant. In pelvic failure, para-aortic lymph nodes metastases and distant metastases showed no statistically significant differences for the 2 groups in each treatment arm. In the para-aortic group, complications were more frequent than in the pelvic group (13/45 vs. 2/48, p [de

  16. Role of pelvic and para-aortic lymphadenectomy in abandoned radical hysterectomy in cervical cancer.

    Science.gov (United States)

    Barquet-Muñoz, Salim Abraham; Rendón-Pereira, Gabriel Jaime; Acuña-González, Denise; Peñate, Monica Vanessa Heymann; Herrera-Montalvo, Luis Alonso; Gallardo-Alvarado, Lenny Nadia; Cantú-de León, David Francisco; Pareja, René

    2017-01-14

    Cervical cancer (CC) occupies fourth place in cancer incidence and mortality worldwide in women, with 560,505 new cases and 284,923 deaths per year. Approximately, nine of every ten (87%) take place in developing countries. When a macroscopic nodal involvement is discovered during a radical hysterectomy (RH), there is controversy in the literature between resect macroscopic lymph node compromise or abandonment of the surgery and sending the patient for standard chemo-radiotherapy treatment. The objective of this study is to compare the prognosis of patients with CC whom RH was abandoned and bilateral pelvic lymphadenectomy and para-aortic lymphadenectomy was performed with that of patients who were only biopsied or with removal of a suspicious lymph node, treated with concomitant radiotherapy/chemotherapy in the standard manner. A descriptive and retrospective study was conducted in two institutions from Mexico and Colombia. Clinical records of patients with early-stage CC programmed for RH with an intraoperative finding of pelvic lymph, para-aortic nodes, or any extracervical involvement that contraindicates the continuation of surgery were obtained. Between January 2007 and December 2012, 42 clinical patients complied with study inclusion criteria and were selected for analysis. In patients with CC whom RH was abandoned due to lymph node affectation, there is no difference in overall survival or in disease-free period between systematic lymphadenectomy and tumor removal or lymph node biopsy, in pelvic lymph nodes as well as in para-aortic lymph nodes, when these patients receive adjuvant treatment with concomitant radiotherapy/chemotherapy. This is a hypothesis-generator study; thus, the recommendation is made to conduct randomized prospective studies to procure better knowledge on the impact of bilateral pelvic and para-aortic lymphadenectomy on this group of patients.

  17. Imaging pelvic floor disorders. 2. rev. ed.

    International Nuclear Information System (INIS)

    Stoker, Jaap; Taylor, Stuart A.; DeLancey, John O.L.

    2008-01-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  18. Occupational lifting and pelvic pain during pregnancy:

    DEFF Research Database (Denmark)

    Larsen, Pernille Stemann; Strandberg-Larsen, Katrine; Juhl, Mette

    2013-01-01

    OBJECTIVES: Pelvic pain during pregnancy is a common ailment, and the disease is a major cause of sickness absence during pregnancy. It is plausible that occupational lifting may be a risk factor of pelvic pain during pregnancy, but no previous studies have examined this specific exposure. The aim...... of this study was to examine the association between occupational lifting and pelvic pain during pregnancy. METHODS: The study comprised 50 143 pregnant women, enrolled in the Danish National Birth Cohort in the period from 1996-2002. During pregnancy, the women provided information on occupational lifting...... (weight load and daily frequency), and six months post partum on pelvic pain. Adjusted odds ratios for pelvic pain during pregnancy according to occupational lifting were calculated by logistic regression. RESULTS: Any self-reported occupational lifting (>1 time/day and loads weighing >10 kg...

  19. Imaging pelvic floor disorders. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Amsterdam Univ. (Netherlands). Dept. of Radiology; Taylor, Stuart A. [University College Hospital, London (United Kingdom). Dept. of Specialist X-Ray; DeLancey, John O.L. (eds.) [Michigan Univ., Ann Arbor, MI (United States). L4000 Women' s Hospital

    2008-07-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  20. A case of multiple cancers in the pelvic organs after radiation for uterine cancer

    International Nuclear Information System (INIS)

    Miyake, Yasuhiro; Kurokawa, Eiji; Iijima, Shohei; Handa, Rio; Kato, Takeshi; Kikkawa, Nobuteru

    2005-01-01

    Patients who have undergone pelvic irradiation are reported to be at an increased risk of subsequently developing malignancies of the pelvic organs. We report a case of multiple cancers in the pelvic organs after radiation therapy for uterine cancer. The patient was a 76-year-old woman who had undergone a hysterectomy with radiation therapy for uterine cancer in 1960. Thereafter, she had undergone a total cystectomy for bladder cancer in 1989; an abdominoperineal resection for rectal cancer with radiation proctitis in February 1991; and a right hemicolectomy for cecum cancer in 1995. Then, in 2005, she was found to have early cancer of the sigmoid colon at the stoma, so that the colon was dissected from the periphery of the stoma, the sigmoid colon was removed, and an artificial anus was reconstructed again. The histopathological diagnosis was early well-differentiated adenocarcinoma. She had undergone three operations for multiple cancers of the large intestine in the pelvis at different times during 16 years since 1989 when the bladder cancer was detected and surgically treated. And she has been alive and well. Long-term follow-up would be mandatory for such patients undergone pelvic irradiation who might be able to survive for a long time with appropriate therapies like this patient. (author)

  1. The Role of Pelvic Floor Muscles in Male Sexual Dysfunction and Pelvic Pain.

    Science.gov (United States)

    Cohen, Deborah; Gonzalez, Joshua; Goldstein, Irwin

    2016-01-01

    Sexual function is essential to good health and well-being in men. The relationship between male sexual function, pelvic floor function, and pelvic pain is complex and only beginning to be appreciated. The objectives of the current review are to examine these complex relationships, and to demonstrate how pelvic floor physical therapy can potentially improve the treatment of various male sexual dysfunctions, including erectile dysfunction and dysfunction of ejaculation and orgasm. Contemporary data on pelvic floor anatomy and function as they relate to the treatment of various male sexual dysfunctions were reviewed. Examination of evidence supporting the association between the male pelvic floor and erectile dysfunction, ejaculatory/orgasmic dysfunction, and chronic prostatitis/chronic pelvic pain syndrome, respectively. Evidence suggests a close relationship between the pelvic floor and male sexual dysfunction and a potential therapeutic benefit from pelvic floor therapy for men who suffer from these conditions. Pelvic floor physical therapy is a necessary tool in a more comprehensive bio-neuromusculoskeletal-psychosocial approach to the treatment of male sexual dysfunction and pelvic pain. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  2. Clinical trial evaluating cholestyramine to prevent diarrhea in patients maintained on low-fat diets during pelvic radiation therapy

    International Nuclear Information System (INIS)

    Chary, S.; Thomson, D.H.

    1984-01-01

    A prospective randomized trial to determine the value of a low fat diet with or without cholestyramine in the treatment of acute intestinal complications of pelvic irradiation is presented. A total of 35 patients receiving pelvic irradiation were entered in the study and all patients had received a 40 gm fat diet. The group was then randomized to receive either placebo (17 patients) or cholestyramine (18 patients). Diarrhea occurred in six out of 16 evaluable patients in the control group and only one of the 17 evaluable patients in the cholestyramine group. The frequency of diarrhea and the diarrhea scale remained high in the placebo group in the entire observation period. Statistical analysis had revealed better diarrhea control in the cholestyramine group. In this report mechanism by which diarrhea occurs following pelvic irradiation is discussed. The adverse effects associated with the use of cholestyramine have been presented. It was concluded that cholestyramine is effective in preventing acute diarrhea induced by pelvic irradiation in patients receiving a low fat diet but is associated with side effects

  3. Reconstruction of Complex Post-Traumatic Perineal/Pelvic Defects ...

    African Journals Online (AJOL)

    of the pelvic diaphragm). A composite pedicled. ALT flap was considered adequate for the initial reconstruction and stabilization, with the option of using a free fibular flap later, should the pelvic ring remain unstable. The fascia was used to complete the pelvic ring. It also provided anterior support to the pelvic diaphragm.

  4. New procedure for criticality search using coarse mesh nodal methods

    International Nuclear Information System (INIS)

    Pereira, Wanderson F.; Silva, Fernando C. da; Martinez, Aquilino S.

    2011-01-01

    The coarse mesh nodal methods have as their primary goal to calculate the neutron flux inside the reactor core. Many computer systems use a specific form of calculation, which is called nodal method. In classical computing systems that use the criticality search is made after the complete convergence of the iterative process of calculating the neutron flux. In this paper, we proposed a new method for the calculation of criticality, condition which will be over very iterative process of calculating the neutron flux. Thus, the processing time for calculating the neutron flux was reduced by half compared with the procedure developed by the Nuclear Engineering Program of COPPE/UFRJ (PEN/COPPE/UFRJ). (author)

  5. New procedure for criticality search using coarse mesh nodal methods

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Wanderson F.; Silva, Fernando C. da; Martinez, Aquilino S., E-mail: wneto@con.ufrj.b, E-mail: fernando@con.ufrj.b, E-mail: Aquilino@lmp.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2011-07-01

    The coarse mesh nodal methods have as their primary goal to calculate the neutron flux inside the reactor core. Many computer systems use a specific form of calculation, which is called nodal method. In classical computing systems that use the criticality search is made after the complete convergence of the iterative process of calculating the neutron flux. In this paper, we proposed a new method for the calculation of criticality, condition which will be over very iterative process of calculating the neutron flux. Thus, the processing time for calculating the neutron flux was reduced by half compared with the procedure developed by the Nuclear Engineering Program of COPPE/UFRJ (PEN/COPPE/UFRJ). (author)

  6. The variational nodal method: history and recent accomplishments

    International Nuclear Information System (INIS)

    Lewis, E.E.

    2004-01-01

    The variational nodal method combines spherical harmonics expansions in angle with hybrid finite element techniques is space to obtain multigroup transport response matrix algorithms applicable to both deep penetration and reactor core physics problems. This survey briefly recounts the method's history and reviews its capabilities. The variational basis for the approach is presented and two methods for obtaining discretized equations in the form of response matrices are detailed. The first is that contained the widely used VARIANT code, while the second incorporates newly developed integral transport techniques into the variational nodal framework. The two approaches are combined with a finite sub element formulation to treat heterogeneous nodes. Applications are presented for both a deep penetration problem and to an OECD benchmark consisting of LWR MOX fuel assemblies. Ongoing work is discussed. (Author)

  7. Radiological signs of extra nodal abdominal involvements in lymphoma

    International Nuclear Information System (INIS)

    Carro, A.I.; Alegre, N.; Cervera, J.L.; Montero, A.I.

    1998-01-01

    To assess abdominal CT images in lymphoma patients for the study of extra nodal abdominal involvement. Ninety-two patients diagnosed as having lymphoma were studied retrospectively. All the patients underwent abdominopelvic CT with oral and intravenous contrast (except in one patient who was allergic). In every case, the diagnosis was confirmed by biopsy or radiological follow-up after treatment had been completed. Fifty-two patients (56.5%) presented infiltration of extra nodal organs. The organs most frequently involved were liver and spleen, followed by the gastrointestinal tract, the musculoskeletal system and the genitourinary tract. The findings in this study coincide with those reported elsewhere with the exception of the splenic involvement the incidence of which was lower in the present series. (Author) 17 refs

  8. On the nodal structure of atomic and molecular Wigner functions

    International Nuclear Information System (INIS)

    Dahl, J.P.; Schmider, H.

    1996-01-01

    In previous work on the phase-space representation of quantum mechanics, we have presented detailed pictures of the electronic one-particle reduced Wigner function for atoms and small molecules. In this communication, we focus upon the nodal structure of the function. On the basis of the simplest systems, we present an expression which relates the oscillatory decay of the Wigner function solely to the dot product of the position and momentum vector, if both arguments are large. We then demonstrate the regular behavior of nodal patterns for the larger systems. For the molecular systems, an argument analogous to the open-quotes bond-oscillatory principleclose quotes for momentum densities links the nuclear framework to an additional oscillatory term in momenta parallel to bonds. It is shown that these are visible in the Wigner function in terms of characteristic nodes

  9. An alternative solver for the nodal expansion method equations - 106

    International Nuclear Information System (INIS)

    Carvalho da Silva, F.; Carlos Marques Alvim, A.; Senra Martinez, A.

    2010-01-01

    An automated procedure for nuclear reactor core design is accomplished by using a quick and accurate 3D nodal code, aiming at solving the diffusion equation, which describes the spatial neutron distribution in the reactor. This paper deals with an alternative solver for nodal expansion method (NEM), with only two inner iterations (mesh sweeps) per outer iteration, thus having the potential to reduce the time required to calculate the power distribution in nuclear reactors, but with accuracy similar to the ones found in conventional NEM. The proposed solver was implemented into a computational system which, besides solving the diffusion equation, also solves the burnup equations governing the gradual changes in material compositions of the core due to fuel depletion. Results confirm the effectiveness of the method for practical purposes. (authors)

  10. Topological and trivial magnetic oscillations in nodal loop semimetals

    Science.gov (United States)

    Oroszlány, László; Dóra, Balázs; Cserti, József; Cortijo, Alberto

    2018-05-01

    Nodal loop semimetals are close descendants of Weyl semimetals and possess a topologically dressed band structure. We argue by combining the conventional theory of magnetic oscillation with topological arguments that nodal loop semimetals host coexisting topological and trivial magnetic oscillations. These originate from mapping the topological properties of the extremal Fermi surface cross sections onto the physics of two dimensional semi-Dirac systems, stemming from merging two massless Dirac cones. By tuning the chemical potential and the direction of magnetic field, a sharp transition is identified from purely trivial oscillations, arising from the Landau levels of a normal two dimensional (2D) electron gas, to a phase where oscillations of topological and trivial origin coexist, originating from 2D massless Dirac and semi-Dirac points, respectively. These could in principle be directly identified in current experiments.

  11. Ischemic stroke associated with radio frequency ablation for nodal reentry

    International Nuclear Information System (INIS)

    Diaz M, Juan C; Duran R, Carlos E; Perafan B, Pablo; Pava M, Luis F

    2010-01-01

    Atrioventricular nodal reentry tachycardia is the most common type of paroxysmal supraventricular tachycardia. In those patients in whom drug therapy is not effective or not desired, radio frequency ablation is an excellent therapeutic method. Although overall these procedures are fast and safe, several complications among which ischemic stroke stands out, have been reported. We present the case of a 41 year old female patient with repetitive episodes of tachycardia due to nodal reentry who was treated with radiofrequency ablation. Immediately after the procedure she presented focal neurologic deficit consistent with ischemic stroke in the right medial cerebral artery territory. Angiography with angioplastia and abxicimab was performed and then tissue plasminogen activator (rtPA) was locally infused, with appropriate clinical and angiographic outcome.

  12. RELAP 4/MOD 6 boiling water nodalization study

    International Nuclear Information System (INIS)

    Sonneck, G.; Pfau, H.

    1985-09-01

    The risk of nuclear steam supply systems is dominated by the core melt accidents. The first step to a realistic assessment of these sequences is the successful prediction of a loss of coolant event in a test loop. One of the codes for that is RELAP 4/MOD 6 and one of the important options in this code is the nodalization. The base of this work is the test LOCA No. 1 FIX II in Studsvik (Sweden) which also served as the OECD International Standard Problem 15. This report discusses the influence of different nodalizations, of different distributions of pressure, water and structural heat as well as of different bubble rise options, break flow coefficients, and heat transfer time steps. The most important result is that a simple RELAP 4/MOD6 model with less than 10 volumes is able to predict an experiment as LOCA No. 1 in FIX II successfully using only a fraction of the usual computing time. (Author)

  13. A nodal model for the simulation of a PWR core

    International Nuclear Information System (INIS)

    Souza Pinto, R. de.

    1981-06-01

    A computer program FORTRAN language was developed to simulate the neutronic and thermal-hydraulic transient behaviour of a PWR reactor core. The reator power is calculated using a point kinectics model with six groups of delayed neutron precursors. The fission product decay heat was considered assuming three effective decay heat groups. A nodal model was employed for the treatment of heat transfer in the fuel rod, with integration of the heat equation by the lumped parameter technique. Axial conduction was neglected. A single-channel nodal model was developed for the thermo-hydrodynamic simulation using mass and energy conservation equations for the control volumes. The effect of the axial pressure variation was neglected. The computer program was tested, with good results, through the simulation of the transient behaviour of postulated accidents in a typical PWR. (Author) [pt

  14. The variational nodal method: some history and recent activity

    International Nuclear Information System (INIS)

    Lewis, E.E.; Smith, M.A.; Palmiotti, G.

    2005-01-01

    The variational nodal method combines spherical harmonics expansions in angle with hybrid finite element techniques in space to obtain multigroup transport response matrix algorithms applicable to a wide variety of reactor physics problems. This survey briefly recounts the method's history and reviews its capabilities. Two methods for obtaining discretized equations in the form of response matrices are compared. The first is that contained the widely used VARIANT code, while the second incorporates more recently developed integral transport techniques into the variational nodal framework. The two approaches are combined with a finite sub-element formulation to treat heterogeneous nodes. Results are presented for application to a deep penetration problem and to an OECD benchmark consisting of LWR Mox fuel assemblies. Ongoing work is discussed. (authors)

  15. Hybrid microscopic depletion model in nodal code DYN3D

    International Nuclear Information System (INIS)

    Bilodid, Y.; Kotlyar, D.; Shwageraus, E.; Fridman, E.; Kliem, S.

    2016-01-01

    Highlights: • A new hybrid method of accounting for spectral history effects is proposed. • Local concentrations of over 1000 nuclides are calculated using micro depletion. • The new method is implemented in nodal code DYN3D and verified. - Abstract: The paper presents a general hybrid method that combines the micro-depletion technique with correction of micro- and macro-diffusion parameters to account for the spectral history effects. The fuel in a core is subjected to time- and space-dependent operational conditions (e.g. coolant density), which cannot be predicted in advance. However, lattice codes assume some average conditions to generate cross sections (XS) for nodal diffusion codes such as DYN3D. Deviation of local operational history from average conditions leads to accumulation of errors in XS, which is referred as spectral history effects. Various methods to account for the spectral history effects, such as spectral index, burnup-averaged operational parameters and micro-depletion, were implemented in some nodal codes. Recently, an alternative method, which characterizes fuel depletion state by burnup and 239 Pu concentration (denoted as Pu-correction) was proposed, implemented in nodal code DYN3D and verified for a wide range of history effects. The method is computationally efficient, however, it has applicability limitations. The current study seeks to improve the accuracy and applicability range of Pu-correction method. The proposed hybrid method combines the micro-depletion method with a XS characterization technique similar to the Pu-correction method. The method was implemented in DYN3D and verified on multiple test cases. The results obtained with DYN3D were compared to those obtained with Monte Carlo code Serpent, which was also used to generate the XS. The observed differences are within the statistical uncertainties.

  16. SPANDOM - source projection analytic nodal discrete ordinates method

    International Nuclear Information System (INIS)

    Kim, Tae Hyeong; Cho, Nam Zin

    1994-01-01

    We describe a new discrete ordinates nodal method for the two-dimensional transport equation. We solve the discrete ordinates equation analytically after the source term is projected and represented in polynomials. The method is applied to two fast reactor benchmark problems and compared with the TWOHEX code. The results indicate that the present method accurately predicts not only multiplication factor but also flux distribution

  17. HEXAN - a hexagonal nodal code for solving the diffusion equation

    International Nuclear Information System (INIS)

    Makai, M.

    1982-07-01

    This report describes the theory of and provides a user's manual for the HEXAN program, which is a nodal program for the solution of the few-group diffusion equation in hexagonal geometry. Based upon symmetry considerations, the theory provides an analytical solution in a homogeneous node. WWER and HTGR test problem solutions are presented. The equivalence of the finite-difference scheme and the response matrix method is proven. The properties of a symmetric node's response matrix are investigated. (author)

  18. Pelvic Mass Due to Transmigrated IUD

    Directory of Open Access Journals (Sweden)

    Nadereh Behtash

    2010-03-01

    Full Text Available Intrauterine device (IUD, a conventional method of contraception is rarely associated with uterine perforation and extra uterine dislocation. A 29 years old woman complaining of vaginal bleeding was referred for pelvic mass identified in ultrasound. The mass was confirmed with CT scan. In laparatomy we found an IUD in cul-de-sac and pelvic mass was apparently an organized hematoma. Transmigrated IUD can induce organized hematomas presenting as a pelvic mass."n© 2010 Tehran University of Medical Sciences. All rights reserved.

  19. Radiology of sport injuries of pelvic apophyses

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, F

    1983-09-01

    Pelvic apophyses are places of insertion of strong muscles and tendons and are therefore places of least resistance at the end of skeletal growth. Avulsions and disruptions of pelvic apophyses can be caused by overstrain during different kinds of sport activity. Typical radiological findings in 8 different cases of ruptures of apophyses, osteochondropathies, and resulting conditions of sport injuries are demonstrated. The difficulties of correct diagnosis and different diagnosis are pointed out. The significance of hormonal impairment of ossification for development and stress factor of pelvic apophyses is exposed. Questions of treatment and follow-up studies are discussed.

  20. Radiology of sport injuries of pelvic apophyses

    International Nuclear Information System (INIS)

    Heuck, F.

    1983-01-01

    Pelvic apophyses are places of insertion of strong muscles and tendons and are therefore places of least resistance at the end of skeletal growth. Avulsions and disruptions of pelvic apophyses can be caused by overstrain during different kinds of sport activity. Typical radiological findings in 8 different cases of ruptures of apophyses, osteochondropathies, and resulting conditions of sport injuries are demonstrated. The difficulties of correct diagnosis and different diagnosis are pointed out. The significance of hormonal impairment of ossification for development and stress factor of pelvic apophyses is exposed. Questions of treatment and follow-up studies are discussed. (orig.)

  1. NOMAD: a nodal microscopic analysis method for nuclear fuel depletion

    International Nuclear Information System (INIS)

    Rajic, H.L.; Ougouag, A.M.

    1987-01-01

    Recently developed assembly homogenization techniques made possible very efficient global burnup calculations based on modern nodal methods. There are two possible ways of modeling the global depletion process: macroscopic and microscopic depletion models. Using a microscopic global depletion approach NOMAD (NOdal Microscopic Analysis Method for Nuclear Fuel Depletion), a multigroup, two- and three-dimensional, multicycle depletion code was devised. The code uses the ILLICO nodal diffusion model. The formalism of the ILLICO methodology is extended to treat changes in the macroscopic cross sections during a depletion cycle without recomputing the coupling coefficients. This results in a computationally very efficient method. The code was tested against a well-known depletion benchmark problem. In this problem a two-dimensional pressurized water reactor is depleted through two cycles. Both cycles were run with 1 x 1 and 2 x 2 nodes per assembly. It is obvious that the one node per assembly solution gives unacceptable results while the 2 x 2 solution gives relative power errors consistently below 2%

  2. Applications of a systematic homogenization theory for nodal diffusion methods

    International Nuclear Information System (INIS)

    Zhang, Hong-bin; Dorning, J.J.

    1992-01-01

    The authors recently have developed a self-consistent and systematic lattice cell and fuel bundle homogenization theory based on a multiple spatial scales asymptotic expansion of the transport equation in the ratio of the mean free path to the reactor characteristics dimension for use with nodal diffusion methods. The mathematical development leads naturally to self-consistent analytical expressions for homogenized diffusion coefficients and cross sections and flux discontinuity factors to be used in nodal diffusion calculations. The expressions for the homogenized nuclear parameters that follow from the systematic homogenization theory (SHT) are different from those for the traditional flux and volume-weighted (FVW) parameters. The calculations summarized here show that the systematic homogenization theory developed recently for nodal diffusion methods yields accurate values for k eff and assembly powers even when compared with the results of a fine mesh transport calculation. Thus, it provides a practical alternative to equivalence theory and GET (Ref. 3) and to simplified equivalence theory, which requires auxiliary fine-mesh calculations for assemblies embedded in a typical environment to determine the discontinuity factors and the equivalent diffusion coefficient for a homogenized assembly

  3. Flow-based market coupling. Stepping stone towards nodal pricing?

    International Nuclear Information System (INIS)

    Van der Welle, A.J.

    2012-07-01

    For achieving one internal energy market for electricity by 2014, market coupling is deployed to integrate national markets into regional markets and ultimately one European electricity market. The extent to which markets can be coupled depends on the available transmission capacities between countries. Since interconnections are congested from time to time, congestion management methods are deployed to divide the scarce available transmission capacities over market participants. For further optimization of the use of available transmission capacities while maintaining current security of supply levels, flow-based market coupling (FBMC) will be implemented in the CWE region by 2013. Although this is an important step forward, important hurdles for efficient congestion management remain. Hence, flow based market coupling is compared to nodal pricing, which is often considered as the most optimal solution from theoretical perspective. In the context of decarbonised power systems it is concluded that advantages of nodal pricing are likely to exceed its disadvantages, warranting further development of FBMC in the direction of nodal pricing.

  4. Recognition and Management of Nonrelaxing Pelvic Floor Dysfunction

    OpenAIRE

    Faubion, Stephanie S.; Shuster, Lynne T.; Bharucha, Adil E.

    2012-01-01

    Nonrelaxing pelvic floor dysfunction is not widely recognized. Unlike in pelvic floor disorders caused by relaxed muscles (eg, pelvic organ prolapse or urinary incontinence, both of which often are identified readily), women affected by nonrelaxing pelvic floor dysfunction may present with a broad range of nonspecific symptoms. These may include pain and problems with defecation, urination, and sexual function, which require relaxation and coordination of pelvic floor muscles and urinary and ...

  5. Pelvic exenteration for locally advanced primary and recurrent pelvic neoplasm: a series of 54 resectable cases

    Directory of Open Access Journals (Sweden)

    Sergio Renato Pais Costa

    2008-09-01

    Full Text Available Objective: To report on a series of 54 patients with pelvic neoplasms submitted to curative pelvic exenteration at a tertiary hospital and describe the results (morbidity, mortality, and long-term survival. Methods: The complete data of 54 patients submitted to pelvic exenteration between 1999 and 2007 were evaluated. Sixteen men and 38 women with a mean age of 65 years and median age of 66 years (36 to 77 were studied. Surgical procedures included total pelvic exenteration (n = 26, anterior pelvic exenteration(n = 5, and posterior pelvic exenteration (n = 23. Rresults: The mean operative time was 402 minutes (280 to 585. The average volume of intraoperative bleeding was 2,013 ml (300 to 5,800. Postoperative mortality was 5% (n = 3. The overall morbidity rate was 46%(n = 25. Histological evaluation demonstrated that 47 resections were R0 (87% while seven were R1 (13%. The overall survival rate in five years was 23.5% (n = 12. Cconclusions: Despite its aggressive nature and high morbidity, pelvic exenteration is still justified in locally advanced pelvic neoplasms or even in isolated pelvic recurrence, since it affords a greater long-term control of the neoplasm.

  6. Imaging findings in idiopathic pelvic fibrosis

    International Nuclear Information System (INIS)

    Wiesner, W.; Bongartz, G.; Stoffel, F.

    2001-01-01

    Two patients presented with ureteric obstruction, and voiding symptoms and constipation, respectively, and were examined by means of intravenous urography and computed tomography. One patient was additionally examined by means of MR tomography. After CT (performed in both patients) and MRT (performed in one patient) had shown a diffuse, contrast-enhancing, infiltrating process in the small pelvis with infiltration of adjacent organs and vessels, surgical biopsy proved the diagnosis of idopathic pelvic fibrosis. Extension of retroperitoneal fibrosis below the pelvic rim is very rare. Clinical symptoms of pelvic fibrosis are variable and imaging findings may lead to a broad list of differential diagnoses. We present two patients with idiopathic pelvic fibrosis and discuss radiological findings and differential diagnoses of this rare disease. (orig.)

  7. Magnetic Resonance Imaging (MRI): Dynamic Pelvic Floor

    Science.gov (United States)

    ... to a CD or uploaded to a digital cloud server. Dynamic pelvic floor MRI provides detailed pictures ... with you. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  8. CT in the evaluation of pelvic trauma

    International Nuclear Information System (INIS)

    Federle, M.P.

    1986-01-01

    Pelvic fractures from motor vehicle accidents are a cause of substantial morbidity and permanent disability, and are the third leading cause of death following blunt trauma. Associated extremity fractures are common, and injury to abdominal and pelvic viscera may occur. Difficulty in establishing the source of hemorrhage may be encountered, especially since pelvic fractures with extraperitoneal bleeding may result in intraperitoneal bleeding through torn fascial planes. The difficulty in properly diagnosing and managing complex fractures of the pelvis and acetabulum is well documented. Prognosis is influenced by the type and extent of pelvic fracture and associated soft tissue injuries. Computed tomography (CT) has proved to be a valuable tool in evaluation of these complex and life-threatening injuries

  9. Pelvic floor electrophysiology patterns associated with faecal ...

    African Journals Online (AJOL)

    Hussein Al-Moghazy Sultan

    2012-12-28

    Dec 28, 2012 ... pelvic floor electrophysiological abnormalities associated with. FI were illustrated in ... detection of a localized anal sphincter defect clinically and ..... Woods R, Voyvodic F, Schloithe A, Sage M, Wattchow D. Anal sphincter ...

  10. Pelvic Inflammatory Disease (PID) Fact Sheet

    Science.gov (United States)

    ... Home Page Bacterial Vaginosis (BV) Chlamydia Genital Herpes Gonorrhea Hepatitis HIV/AIDS & STDs Human Papillomavirus (HPV) Pelvic ... often caused by some STDs, like chlamydia and gonorrhea . Other infections that are not sexually transmitted can ...

  11. Imaging findings in idiopathic pelvic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Wiesner, W.; Bongartz, G. [Inst. of Diagnostic Radiology University Hospital Basel (Switzerland); Stoffel, F. [Inst. of Urology, University Hospital Basel (Switzerland)

    2001-04-01

    Two patients presented with ureteric obstruction, and voiding symptoms and constipation, respectively, and were examined by means of intravenous urography and computed tomography. One patient was additionally examined by means of MR tomography. After CT (performed in both patients) and MRT (performed in one patient) had shown a diffuse, contrast-enhancing, infiltrating process in the small pelvis with infiltration of adjacent organs and vessels, surgical biopsy proved the diagnosis of idopathic pelvic fibrosis. Extension of retroperitoneal fibrosis below the pelvic rim is very rare. Clinical symptoms of pelvic fibrosis are variable and imaging findings may lead to a broad list of differential diagnoses. We present two patients with idiopathic pelvic fibrosis and discuss radiological findings and differential diagnoses of this rare disease. (orig.)

  12. Pelvic Surgical Site Infections in Gynecologic Surgery

    Directory of Open Access Journals (Sweden)

    Mark P. Lachiewicz

    2015-01-01

    Full Text Available The development of surgical site infection (SSI remains the most common complication of gynecologic surgical procedures and results in significant patient morbidity. Gynecologic procedures pose a unique challenge in that potential pathogenic microorganisms from the skin or vagina and endocervix may migrate to operative sites and can result in vaginal cuff cellulitis, pelvic cellulitis, and pelvic abscesses. Multiple host and surgical risk factors have been identified as risks that increase infectious sequelae after pelvic surgery. This paper will review these risk factors as many are modifiable and care should be taken to address such factors in order to decrease the chance of infection. We will also review the definitions, microbiology, pathogenesis, diagnosis, and management of pelvic SSIs after gynecologic surgery.

  13. Effect of ion beam irradiation on morphological and flowering characteristics of chrysanthemum

    International Nuclear Information System (INIS)

    Shakinah Salleh; Zaiton Ahmad; Affrida Abu Hassan; Thohiroh Lee Abdullah

    2012-01-01

    Chrysanthemum morifolium is an important temperate cut flower for Malaysian floriculture industry and the lack of new local owned varieties led to this mutation breeding research. The objective of this study was to compare the effectiveness of ion beam irradiation in generating mutations on ray florets and nodal explants of Chrysanthemum morifolium cv. Reagan Red. Ion beams has become a new physical mutagens for mutation breeding. The ray florets and nodal explants were irradiated with ion beam at doses 0, 0.5, 1.0, 2.0, 3.0, 5.0, 8.0, 10, 15, 20 and 30 Gy. The 50 % of in vitro shoot regeneration (RD 50 ) for ray florets explants was 2.0 Gy and for nodal explants was 4.0 Gy. Thus, relative biological effectiveness (RBE) for ray florets was found 2.0 times higher than the nodal explants. The regenerated plant lets were planted in the greenhouse at MARDI, Cameron Highlands for morphological screening. Overall performance of survival plant lets derived from in vitro nodal and ray florets explants was recorded. The characters studied include plant morphology and flowering characteristic. The ray florets explants were found to be more sensitive to ion beam irradiation and generated more mutations as compared to nodal explants. (author)

  14. Preoperative evaluation of locally spreaded pelvic tumors

    International Nuclear Information System (INIS)

    Baramia, M.; Todua, F.; Gotsadze, D.; Khutulashvili, N.; Lashkhi, K.; Nadareishvili, A.

    1998-01-01

    Am of the study: preoperative evaluation of patients with locally advanced pelvic tumors subjected to pelvic exenteration. Determine operability to avoid explorative laparatomies, which cause serious complications in these patients. Evaluate condition of urinary system in case of this pathology. Materials and methods: 34 patients with locally advanced pelvic tumors where pelvic exenteration was attempted were studied. Along with other methods of diagnostic CT and MRI were performed. Results: In all patients secondary involvement of the urinary bladder was noted. In 30 patients CT and MR findings were confirmed (88,2%) intraoperatively and different types of pelvic organs exenteration were performed. In 1 case spread of tomoruos infiltrate to the pelvic wall and common iliac vessels was detected intraoperatively (patient had history of radiation therapy). In 2 cases carcinomatosis of the peritoneum was found. In 1 case involvement of urinary bladder was simulated by close attachment of enlarged uterus. Conclusion: Obtained results show, that CT and MR are highly informative methods of disease spread evaluation and thus determining operability. Radiotherapy performed prior to operation sets difficulties in differentiation for tumourous infiltrate and post-radiotherapy changes in pelvis. (Full text)

  15. Pelvic floor and sexual male dysfunction

    Directory of Open Access Journals (Sweden)

    Antonella Pischedda

    2013-04-01

    Full Text Available The pelvic floor is a complex multifunctional structure that corresponds to the genito- urinary-anal area and consists of muscle and connective tissue. It supports the urinary, fecal, sexual and reproductive functions and pelvic statics. The symptoms caused by pelvic floor dysfunction often affect the quality of life of those who are afflicted, worsening significantly more aspects of daily life. In fact, in addition to providing support to the pelvic organs, the deep floor muscles support urinary continence and intestinal emptying whereas the superficial floor muscles are involved in the mechanism of erection and ejaculation. So, conditions of muscle hypotonia or hypertonicity may affect the efficiency of the pelvic floor, altering both the functionality of the deep and superficial floor muscles. In this evolution of knowledge it is possible imagine how the rehabilitation techniques of pelvic floor muscles, if altered and able to support a voiding or evacuative or sexual dysfunction, may have a role in improving the health and the quality of life.

  16. Effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction

    Directory of Open Access Journals (Sweden)

    Shi-Qiong Li

    2017-04-01

    Full Text Available Objective: To explore the effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction and on the sexual life quality. Methods: A total of 286 puerpera with pelvic floor dysfunction who were admitted in our hospital from May, 2014 to May, 2015 42 d after delivery were included in the study, and randomized into the treatment group and the control group with 143 cases in each group. After guidance, the puerpera in the control group were given pelvic floor muscle training by themselves at home. On this basis, the puerpera in the treatment group were treated by the pelvic floor rehabilitation apparatus. The puerpera in the two groups were treated for 4 weeks. The pelvic floor function before treatment, 6 months and 1 year after delivery was detected. The color Doppler ultrasound apparatus was used to detect BSD, PUVA, UVJ-M, and BND 3 months after delivery. Results: BND, PUVA-R, PUVA-S, and UVJ-M 3 months after delivery in the treatment groups were significantly lower than those in the control group, while BSD-S was significantly higher than that in the control group. The improvement of type I and II muscle fiber fatigue (%, POP-Q degree, AP indication point (cm, and vaginal dynamic pressure (cmH2O was significantly superior to that in the control group. The comparison of pelvic floor muscle strength classification before treatment between the two groups was not statistically significant. After treatment, the pelvic floor muscle in the two groups was significantly strengthened, and the proportion of V grade patients was significantly increased when compared with before treatment. Conclusions: The postpartum early pelvic floor rehabilitation technique can effectively enhance the pelvic floor function, and prevent the postpartum pelvic floor dysfunction, with an accurate efficacy; therefore, it deserves to be widely recommended in the clinic.

  17. A comparison between stabilization exercises and pelvic floor muscle training in women with pelvic organ prolapse

    Directory of Open Access Journals (Sweden)

    Nuriye Özengin

    2015-03-01

    Full Text Available Objective: This study aimed to compare the effectiveness of stabilization exercises and pelvic floor muscle training in women with stage 1 and 2 pelvic organ prolapse. Materials and Methods: In a total 38 women with pelvic organ prolapse whose average age was 45.60 years, pelvic floor muscles were evaluated with electromyography, and prolapse with pelvic organ prolapse quantification system, and the quality of life with prolapse quality of life questionnaire. Afterwards, the subjects were divided into two groups; stabilization exercise group (n=19 and pelvic floor muscle training group (n=19. Stabilization exercise group were given training for 8 weeks, 3 times a week. Pelvic floor muscle training group were given eight-week home exercises. Each group was assessed before training and after eight weeks. Results: An increase was found in the pelvic muscle activation response in the 2 groups (p≤0.05. There was no difference in EMG activity values between the groups (p>0.05. A difference was found in the values Aa, Ba and C in subjects of each group (p≤0.05, and the TVL, Ap, Bp and D values of subjects in pelvic floor muscle training group (p≤0.05 in the before and after pelvic organ prolapse quantification system assessment, however, no difference was found between the groups (p≤0.05. A positive difference was found in the effect of prolapse sub parameter in each of the two groups, and in general health perception sub parameter in subjects of stabilization exercise group (p<0.05 in the prolapse quality of life questionnaire. Conclusions: It was concluded that both training programs increased the pelvic floor muscle strength, provided a decline in prolapse stages. Stabilization exercise has increased general health perception unlike home training, thus, these exercises can be added to the treatment of women with prolapse.

  18. Consensus Guidelines and Contouring Atlas for Pelvic Node Delineation in Prostate and Pelvic Node Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Victoria A. [Academic Urology Unit, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, London (United Kingdom); Staffurth, John [Institute of Cancer and Genetics, School of Medicine, Cardiff University, Cardiff, Wales (United Kingdom); Naismith, Olivia [Joint Department of Physics, Institute of Cancer Research, and Royal Marsden NHS Foundation Trust, London (United Kingdom); Esmail, Alikhan [Ipswich Hospital NHS Foundation Trust, Ipswich (United Kingdom); Gulliford, Sarah [Joint Department of Physics, Institute of Cancer Research, and Royal Marsden NHS Foundation Trust, London (United Kingdom); Khoo, Vincent [Department of Radiotherapy, The Royal Marsden NHS Foundation Trust, London (United Kingdom); Lewis, Rebecca [Clinical Trials and Statistics Unit, Institute of Cancer Research, London (United Kingdom); Littler, John [Clatterbridge Cancer Centre, Liverpool (United Kingdom); McNair, Helen [Department of Radiotherapy, The Royal Marsden NHS Foundation Trust, London (United Kingdom); Sadoyze, Azmat [Beatson West of Scotland Cancer Centre, Scotland, Glasgow (United Kingdom); Scrase, Christopher [Ipswich Hospital NHS Foundation Trust, Ipswich (United Kingdom); Sohaib, Aslam [Department of Radiology, The Royal Marsden NHS Foundation Trust, London (United Kingdom); Syndikus, Isabel [Clatterbridge Cancer Centre, Liverpool (United Kingdom); Zarkar, Anjali [University Hospitals Birmingham NHS Foundation Trust, Birmingham (United Kingdom); Hall, Emma [Clinical Trials and Statistics Unit, Institute of Cancer Research, London (United Kingdom); Dearnaley, David, E-mail: David.Dearnaley@icr.ac.uk [Academic Urology Unit, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, London (United Kingdom)

    2015-07-15

    Purpose: The purpose of this study was to establish reproducible guidelines for delineating the clinical target volume (CTV) of the pelvic lymph nodes (LN) by combining the freehand Royal Marsden Hospital (RMH) and Radiation Therapy Oncology Group (RTOG) vascular expansion techniques. Methods and Materials: Seven patients with prostate cancer underwent standard planning computed tomography scanning. Four different CTVs (RMH, RTOG, modified RTOG, and Prostate and pelvIs Versus prOsTate Alone treatment for Locally advanced prostate cancer [PIVOTAL] trial) were created for each patient, and 6 different bowel expansion margins (BEM) were created to assess bowel avoidance by the CTV. The resulting CTVs were compared visually and by using Jaccard conformity indices. The volume of overlap between bowel and planning target volume (PTV) was measured to aid selection of an appropriate BEM to enable maximal LN yet minimal normal tissue coverage. Results: In total, 84 nodal contours were evaluated. LN coverage was similar in all groups, with all of the vascular-expansion techniques (RTOG, modified RTOG, and PIVOTAL), resulting in larger CTVs than that of the RMH technique (mean volumes: 287.3 cm{sup 3}, 326.7 cm{sup 3}, 310.3 cm{sup 3}, and 256.7 cm{sup 3}, respectively). Mean volumes of bowel within the modified RTOG PTV were 19.5 cm{sup 3} (with 0 mm BEM), 17.4 cm{sup 3} (1-mm BEM), 10.8 cm{sup 3} (2-mm BEM), 6.9 cm{sup 3} (3-mm BEM), 5.0 cm{sup 3} (4-mm BEM), and 1.4 cm{sup 3} (5-mm BEM) in comparison with an overlap of 9.2 cm{sup 3} seen using the RMH technique. Evaluation of conformity between LN-CTVs from each technique revealed similar volumes and coverage. Conclusions: Vascular expansion techniques result in larger LN-CTVs than the freehand RMH technique. Because the RMH technique is supported by phase 1 and 2 trial safety data, we proposed modifications to the RTOG technique, including the addition of a 3-mm BEM, which resulted in LN-CTV coverage similar

  19. Are Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm Applicable to Other Malignancies—Assessment of Nodal Distribution in Gynecological Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Kabolizadeh, Peyman; Fulay, Suyash; Beriwal, Sushil, E-mail: beriwals@upmc.edu

    2013-09-01

    Purpose: Intensity modulated radiation therapy is used to reduce dose to adjacent critical structures while maintaining adequate target coverage, but it requires precise target localization. We report the 3-dimensional distribution of para-aortic (PA) lymph nodes (LN) in pelvic malignancies. We propose a guideline to accurately define the PA LN by anatomic landmarks and compare our data with published guidelines for pancreatic cancer. Methods and Materials: A retrospective analysis was performed on 46 patients with pelvic malignancies and positive PA LNs. Positive LNs were defined based on size and morphology or fluorodeoxyglucose avidity. All PA LNs were characterized into 3 groups based on location: left PA (between aorta and left psoas muscle), aortocaval (between aorta and inferior vena cava), and right paracaval (between inferior vena cava and right psoas muscle). Patients with retrocrural LNs were also analyzed. Results: One hundred thirty-three positive PA LNs were evaluated. The majority of the PA LNs were in the left PA (59%) and aortocaval (35) regions, and only 8% were in the right paracaval region. All patients with positive right paracaval LNs also had involved left PA LNs, with only 1 exception. The highest PA LN involvement was at the level of the renal vessels and was seen in 28% of patients. Of these patients with disease extending to renal vessels, 38% had retrocrural LN involvement. Conclusions: The nodal contouring for the PA region should not be defined by a fixed circumferential margin around the vessels. The left PA and aortocaval spaces should be covered adequately because these are common locations of PA LNs. For microscopic disease superiorly, contouring should extend up to renal vessels rather than a fixed bony landmark. For patients who have nodal involvement at renal vessels, one can consider including retrocrural LNs. Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm are not applicable to

  20. Are Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm Applicable to Other Malignancies—Assessment of Nodal Distribution in Gynecological Malignancies

    International Nuclear Information System (INIS)

    Kabolizadeh, Peyman; Fulay, Suyash; Beriwal, Sushil

    2013-01-01

    Purpose: Intensity modulated radiation therapy is used to reduce dose to adjacent critical structures while maintaining adequate target coverage, but it requires precise target localization. We report the 3-dimensional distribution of para-aortic (PA) lymph nodes (LN) in pelvic malignancies. We propose a guideline to accurately define the PA LN by anatomic landmarks and compare our data with published guidelines for pancreatic cancer. Methods and Materials: A retrospective analysis was performed on 46 patients with pelvic malignancies and positive PA LNs. Positive LNs were defined based on size and morphology or fluorodeoxyglucose avidity. All PA LNs were characterized into 3 groups based on location: left PA (between aorta and left psoas muscle), aortocaval (between aorta and inferior vena cava), and right paracaval (between inferior vena cava and right psoas muscle). Patients with retrocrural LNs were also analyzed. Results: One hundred thirty-three positive PA LNs were evaluated. The majority of the PA LNs were in the left PA (59%) and aortocaval (35) regions, and only 8% were in the right paracaval region. All patients with positive right paracaval LNs also had involved left PA LNs, with only 1 exception. The highest PA LN involvement was at the level of the renal vessels and was seen in 28% of patients. Of these patients with disease extending to renal vessels, 38% had retrocrural LN involvement. Conclusions: The nodal contouring for the PA region should not be defined by a fixed circumferential margin around the vessels. The left PA and aortocaval spaces should be covered adequately because these are common locations of PA LNs. For microscopic disease superiorly, contouring should extend up to renal vessels rather than a fixed bony landmark. For patients who have nodal involvement at renal vessels, one can consider including retrocrural LNs. Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm are not applicable to

  1. Radiotherapy studies and extra-nodal non-Hodgkin lymphomas, progress and challenges

    DEFF Research Database (Denmark)

    Specht, L

    2012-01-01

    Extra-nodal lymphomas may arise in any organ, and different histological subtypes occur in distinct patterns. Prognosis and treatment depend not only on the histological subtype and disease extent, but also on the particular involved extra-nodal organ. The clinical course and response to treatment...... for the more common extra-nodal organs, e.g. stomach, Waldeyer's ring, skin and brain, are fairly well known and show significant variation. A few randomised trials have been carried out testing the role of radiotherapy in these lymphomas. However, for most extra-nodal lymphomas, randomised trials have...... not been carried out, and treatment decisions are made on small patient series and extrapolations from nodal lymphomas. Hopefully, wide international collaboration will make controlled clinical trials possible in the less common extra-nodal lymphomas. Modern highly conformal radiotherapy allows better...

  2. Solution and study of nodal neutron transport equation applying the LTSN-DiagExp method

    International Nuclear Information System (INIS)

    Hauser, Eliete Biasotto; Pazos, Ruben Panta; Vilhena, Marco Tullio de; Barros, Ricardo Carvalho de

    2003-01-01

    In this paper we report advances about the three-dimensional nodal discrete-ordinates approximations of neutron transport equation for Cartesian geometry. We use the combined collocation method of the angular variables and nodal approach for the spatial variables. By nodal approach we mean the iterated transverse integration of the S N equations. This procedure leads to the set of one-dimensional averages angular fluxes in each spatial variable. The resulting system of equations is solved with the LTS N method, first applying the Laplace transform to the set of the nodal S N equations and then obtained the solution by symbolic computation. We include the LTS N method by diagonalization to solve the nodal neutron transport equation and then we outline the convergence of these nodal-LTS N approximations with the help of a norm associated to the quadrature formula used to approximate the integral term of the neutron transport equation. (author)

  3. Five-point form of the nodal diffusion method and comparison with finite-difference

    International Nuclear Information System (INIS)

    Azmy, Y.Y.

    1988-01-01

    Nodal Methods have been derived, implemented and numerically tested for several problems in physics and engineering. In the field of nuclear engineering, many nodal formalisms have been used for the neutron diffusion equation, all yielding results which were far more computationally efficient than conventional Finite Difference (FD) and Finite Element (FE) methods. However, not much effort has been devoted to theoretically comparing nodal and FD methods in order to explain the very high accuracy of the former. In this summary we outline the derivation of a simple five-point form for the lowest order nodal method and compare it to the traditional five-point, edge-centered FD scheme. The effect of the observed differences on the accuracy of the respective methods is established by considering a simple test problem. It must be emphasized that the nodal five-point scheme derived here is mathematically equivalent to previously derived lowest order nodal methods. 7 refs., 1 tab

  4. A Nodal-independent and tissue-intrinsic mechanism controls heart-looping chirality

    Science.gov (United States)

    Noël, Emily S.; Verhoeven, Manon; Lagendijk, Anne Karine; Tessadori, Federico; Smith, Kelly; Choorapoikayil, Suma; den Hertog, Jeroen; Bakkers, Jeroen

    2013-11-01

    Breaking left-right symmetry in bilateria is a major event during embryo development that is required for asymmetric organ position, directional organ looping and lateralized organ function in the adult. Asymmetric expression of Nodal-related genes is hypothesized to be the driving force behind regulation of organ laterality. Here we identify a Nodal-independent mechanism that drives asymmetric heart looping in zebrafish embryos. In a unique mutant defective for the Nodal-related southpaw gene, preferential dextral looping in the heart is maintained, whereas gut and brain asymmetries are randomized. As genetic and pharmacological inhibition of Nodal signalling does not abolish heart asymmetry, a yet undiscovered mechanism controls heart chirality. This mechanism is tissue intrinsic, as explanted hearts maintain ex vivo retain chiral looping behaviour and require actin polymerization and myosin II activity. We find that Nodal signalling regulates actin gene expression, supporting a model in which Nodal signalling amplifies this tissue-intrinsic mechanism of heart looping.

  5. Elsevier Trophoblast Research Award lecture: The multifaceted role of Nodal signaling during mammalian reproduction.

    Science.gov (United States)

    Park, C B; Dufort, D

    2011-03-01

    Nodal, a secreted signaling protein in the transforming growth factor-beta (TGF-β) superfamily, has established roles in vertebrate development. However, components of the Nodal signaling pathway are also expressed at the maternal-fetal interface and have been implicated in many processes of mammalian reproduction. Emerging evidence indicates that Nodal and its extracellular inhibitor Lefty are expressed in the uterus and complex interactions between the two proteins mediate menstruation, decidualization and embryo implantation. Furthermore, several studies have shown that Nodal from both fetal and maternal sources may regulate trophoblast cell fate and facilitate placentation as both embryonic and uterine-specific Nodal knockout mouse strains exhibit disrupted placenta morphology. Here we review the established and prospective roles of Nodal signaling in facilitating successful pregnancy, including recent evidence supporting a potential link to parturition and preterm birth. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Pelvic interstitial brachytherapy - improving the therapeutic ratio with magnetic resonance imaging and optimization

    International Nuclear Information System (INIS)

    Swift, Patrick S.; Hricak, Hedvig; Forstner, Rosemary; Powell, C. Bethan; Purser, Phil; Weaver, Keith; Phillips, Theodore L.

    1996-01-01

    died with distant disease only, and 3 died with both local and distant failure. Of the 8 patients alive with disease, 3 had nodal failures, 3 hepatic, 2 pulmonary and 1 bone, 0 with local failure. Acute complications requiring medical or surgical intervention occurred in only one patient, and delayed complications in 4 (2 of whom were found to have massive central recurrence) for an actuarial two year incidence of 9%. Discussion The use of magnetic resonance imaging for preplanning interstitial pelvic brachytherapy procedures immediately prior to the time of implant provides valuable information for identifying the volume to be implanted and the position of normal tissues put at high risk by implantation. Using this information to guide the isodose optimization programs for remote afterloaders, the therapeutic ratio for interstitial pelvic brachytherapy can be significantly enhanced

  7. Prevalence of myofascial chronic pelvic pain and the effectiveness of pelvic floor physical therapy.

    Science.gov (United States)

    Bedaiwy, Mohamed A; Patterson, Betsy; Mahajan, Sangeeta

    2013-01-01

    To determine the prevalence of myofascial pain and the outcome of transvaginal pelvic floor physical therapy for the treatment of chronic pelvic pain caused by myofascial pelvic pain in a tertiary care facility. A retrospective chart review was performed on all women who presented to our facility between January 2005 and December 2007. Those diagnosed with myofascial pelvic pain and referred for transvaginal pelvic floor physical therapy over this 3-year period were evaluated. Participants with an initial pain score of > or = 4, myofascial pelvic pain on examination, and who attended 2 or more physician visits were included in the analysis. Patient physical examination findings, symptoms, and verbal pain ratings were reviewed. In all, 146 (13.2%) of 1,106 initially screened patients were diagnosed with myofascial pain. Seventy-five (51%) of the 146 patients who were referred for physical therapy were included, and 75% had an initial pain score of > or = 7. Pain scores significantly improved proportional to the number of physical therapy visits completed, with 63% of patients reporting significant pain improvement. Transvaginal physical therapy is an effective treatment for chronic pelvic pain resulting from myofascial pelvic pain.

  8. Triple pelvic ring fixation in patients with severe pregnancy-related low back and pelvic pain.

    NARCIS (Netherlands)

    Zwienen, C.M. van; Bosch, E.W. van den; Snijders, C.J.; Vugt, A.B. van

    2004-01-01

    STUDY DESIGN: Single-group prospective follow-up study. OBJECTIVES: To assess the functional outcome of internal fixation of the pelvic ring in patients with severe pregnancy-related low back and pelvic pain (PLBP) in whom all other treatments failed. BACKGROUND DATA: More than half of all pregnant

  9. Lifestyle advice with or without pelvic floor muscle training for pelvic organ prolapse

    DEFF Research Database (Denmark)

    Due, Ulla; Brostrøm, Søren; Lose, Gunnar

    2016-01-01

    INTRODUCTION AND HYPOTHESIS: We evaluated the effect of adding pelvic floor muscle training (PFMT) to a structured lifestyle advice program. METHODS: This was a single-blinded randomized trial of women with symptomatic pelvic organ prolapse (POP) stage ≥ II. Participants were randomized...

  10. [Imaging of pelvic organ prolapse].

    Science.gov (United States)

    Lapray, Jean-François

    2013-01-01

    Colpocystodefecography (CCD) and dynamic MRI with defecography (MRId) allow an alternation between filling and emptying the hollow organs and the maximum abdominal strain offered by the defecation. When applied in imaging these two principles reveal the masked or underestimated prolapses at the time of the physical examination. A rigorous application of the technique guarantees almost equivalent results from the two examinations. The CCD provides voiding views and improved analysis of the anorectal pathology (intussusception, anismus) but involves radiation and a more invasive examination. MRId has the advantage of providing continuous visibility of the peritoneal compartment, and a multiplanar representation, enabling an examination of the morphology of the pelvic organs and of the supporting structures, with the disadvantage of still necessitating a supine examination, resulting sometimes in an incomplete or impossible evacuation. The normal and abnormal results (cystoptosis, vaginal vault prolapse, enterocele, anorectal intussuception, rectocele, descending perineum, urinary and fecal incontinence) and the respective advantages and limits of the various imaging methods are detailed. Dynamic perineal and introital ultrasound remains more limited in the appreciation of posterior colpoceles and especially in anorectal disorders, than CCD or MRId. Endoanal ultrasound is the first line morphological evaluation of the anal sphincter. Transvaginal and introital ultrasound can detect some complications of suburethral tapes and meshes. Morphological and dynamic imaging are essential complementary tools to the physical examination, especially when a precise anatomic assessment is required to understand the functional complaint or when a reintervention is needed.

  11. Pattern of occult nodal relapse diagnosed with 18F-fluoro-choline PET/CT in prostate cancer patients with biochemical failure after prostate-only radiotherapy

    International Nuclear Information System (INIS)

    Lépinoy, Alexis; Cochet, Alexandre; Cueff, Adèle; Cormier, Luc; Martin, Etienne; Maingon, Philippe; Bosset, Jean François; Brunotte, François; Créhange, Gilles

    2014-01-01

    Introduction: The purpose of this study was to describe the pattern of nodal relapse with 18 F-fluoro-choline (FCH) Positron Emission Tomography/Computerized Tomography (PET/CT) in prostate cancer patients after radiotherapy. Materials and methods: Eighty-three patients had a FCH PET/CT at time of biochemical failure. Of 65 patients with positive findings, 33 had positive nodes. This analysis included 31 patients who had undergone prior prostate-only radiotherapy with or without a prior radical prostatectomy. Each FCH positive node was assigned to a lymph node station with respect to the CTV defined by the RTOG guidelines (CTV RTOG ). 3D mapping was performed after each node was manually placed in a reference planning CT scan after automatic co-registration of the two scans based on bone anatomy. Eighteen patients (58%) underwent focal salvage FCH PET-guided stereotactic radiotherapy with no hormones. Results: Fourteen patients (45.2%) had a relapse outside the CTV RTOG . Of the 17 patients with a positive node inside the CTV RTOG , 15 had a single node (88.2%) while seven patients out of the 13 evaluable patients (53.9%) who had a relapse outside the CTV RTOG had ⩾2 positive nodes on FCH PET/CT (OR = 8.75, [95% CI: 1.38–54.80], p = 0.020). Relapses that occurred outside the CTV RTOG involved the proximal common iliac (19.3%) and lower periaortic nodes (19.3%) up to L2–L3. Conclusion: 3D mapping of nodal relapses evaluated with FCH PET/CT suggests that with IMRT the upper field limit of pelvic radiotherapy could be extended to L2–L3 safely to cover 95% of nodal stations at risk of an occult relapse

  12. A Web-based nomogram predicting para-aortic nodal metastasis in incompletely staged patients with endometrial cancer: a Korean Multicenter Study.

    Science.gov (United States)

    Kang, Sokbom; Lee, Jong-Min; Lee, Jae-Kwan; Kim, Jae-Weon; Cho, Chi-Heum; Kim, Seok-Mo; Park, Sang-Yoon; Park, Chan-Yong; Kim, Ki-Tae

    2014-03-01

    The purpose of this study is to develop a Web-based nomogram for predicting the individualized risk of para-aortic nodal metastasis in incompletely staged patients with endometrial cancer. From 8 institutions, the medical records of 397 patients who underwent pelvic and para-aortic lymphadenectomy as a surgical staging procedure were retrospectively reviewed. A multivariate logistic regression model was created and internally validated by rigorous bootstrap resampling methods. Finally, the model was transformed into a user-friendly Web-based nomogram (http://http://www.kgog.org/nomogram/empa001.html). The rate of para-aortic nodal metastasis was 14.4% (57/397 patients). Using a stepwise variable selection, 4 variables including deep myometrial invasion, non-endometrioid subtype, lymphovascular space invasion, and log-transformed CA-125 levels were finally adopted. After 1000 repetitions of bootstrapping, all of these 4 variables retained a significant association with para-aortic nodal metastasis in the multivariate analysis-deep myometrial invasion (P = 0.001), non-endometrioid histologic subtype (P = 0.034), lymphovascular space invasion (P = 0.003), and log-transformed serum CA-125 levels (P = 0.004). The model showed good discrimination (C statistics = 0.87; 95% confidence interval, 0.82-0.92) and accurate calibration (Hosmer-Lemeshow P = 0.74). This nomogram showed good performance in predicting para-aortic metastasis in patients with endometrial cancer. The tool may be useful in determining the extent of lymphadenectomy after incomplete surgery.

  13. Nodal wear model: corrosion in carbon blast furnace hearths

    International Nuclear Information System (INIS)

    Verdeja, L. F.; Gonzalez, R.; Alfonso, A.; Barbes, M. F.

    2003-01-01

    Criteria developed for the Nodal Wear Model (NWM) were applied to estimate the shape of the corrosion profiles that a blast furnace hearth may acquire during its campaign. Taking into account design of the hearth, the boundary conditions, the characteristics of the refractory materials used and the operation conditions of the blast furnace, simulation of wear profiles with central well, mushroom and elephant foot shape were accomplished. The foundations of the NWM are constructed considering that the corrosion of the refractory is a function of the temperature present at each point (node) of the liquid metal-refractory interface and the corresponding physical and chemical characteristics of the corrosive fluid. (Author) 31 refs

  14. Mechanism of polyuria and natriuresis in atrioventricular nodal tachycardia.

    Science.gov (United States)

    Canepa-Anson, R; Williams, M; Marshall, J; Mitsuoka, T; Lightman, S; Sutton, R

    1984-01-01

    A woman with tachycardia associated with polyuria was investigated. Electrophysiological analysis showed that the tachycardia was an atrioventricular nodal re-entrant tachycardia. Programmed stimulation was then used to provoke and sustain the tachycardia for 40 minutes. Polyuria, with an appreciable increase in free water clearance, was observed. This was associated with reduction in plasma and urinary arginine vasopressin concentrations. Appreciable natriuresis also developed. These results support the hypothesis that the polyuria with increased free water clearance and the natriuresis occurring during sustained tachycardia in man are due to inhibition of secretion of vasopressin and the release of natriuretic factor. PMID:6434116

  15. Approximate Schur complement preconditioning of the lowest order nodal discretizations

    Energy Technology Data Exchange (ETDEWEB)

    Moulton, J.D.; Ascher, U.M. [Univ. of British Columbia, Vancouver, British Columbia (Canada); Morel, J.E. [Los Alamos National Lab., NM (United States)

    1996-12-31

    Particular classes of nodal methods and mixed hybrid finite element methods lead to equivalent, robust and accurate discretizations of 2nd order elliptic PDEs. However, widespread popularity of these discretizations has been hindered by the awkward linear systems which result. The present work exploits this awkwardness, which provides a natural partitioning of the linear system, by defining two optimal preconditioners based on approximate Schur complements. Central to the optimal performance of these preconditioners is their sparsity structure which is compatible with Dendy`s black box multigrid code.

  16. Evaluation of the use of nodal methods for MTR neutronic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Reitsma, F.; Mueller, E.Z.

    1997-08-01

    Although modern nodal methods are used extensively in the nuclear power industry, their use for research reactor analysis has been very limited. The suitability of nodal methods for material testing reactor analysis is investigated with the emphasis on the modelling of the core region (fuel assemblies). The nodal approach`s performance is compared with that of the traditional finite-difference fine mesh approach. The advantages of using nodal methods coupled with integrated cross section generation systems are highlighted, especially with respect to data preparation, simplicity of use and the possibility of performing a great variety of reactor calculations subject to strict time limitations such as are required for the RERTR program.

  17. Nodal line optimization and its application to violin top plate design

    Science.gov (United States)

    Yu, Yonggyun; Jang, In Gwun; Kim, In Kyum; Kwak, Byung Man

    2010-10-01

    In the literature, most problems of structural vibration have been formulated to adjust a specific natural frequency: for example, to maximize the first natural frequency. In musical instruments like a violin; however, mode shapes are equally important because they are related to sound quality in the way that natural frequencies are related to the octave. The shapes of nodal lines, which represent the natural mode shapes, are generally known to have a unique feature for good violins. Among the few studies on mode shape optimization, one typical study addresses the optimization of nodal point location for reducing vibration in a one-dimensional beam structure. However, nodal line optimization, which is required in violin plate design, has not yet been considered. In this paper, the central idea of controlling the shape of the nodal lines is proposed and then applied to violin top plate design. Finite element model for a violin top plate was constructed using shell elements. Then, optimization was performed to minimize the square sum of the displacement of selected nodes located along the target nodal lines by varying the thicknesses of the top plate. We conducted nodal line optimization for the second and the fifth modes together at the same time, and the results showed that the nodal lines obtained match well with the target nodal lines. The information on plate thickness distribution from nodal line optimization would be valuable for tailored trimming of a violin top plate for the given performances.

  18. Time-dependent patterning of the mesoderm and endoderm by Nodal signals in zebrafish

    Directory of Open Access Journals (Sweden)

    Dougan Scott T

    2007-03-01

    Full Text Available Abstract Background The vertebrate body plan is generated during gastrulation with the formation of the three germ layers. Members of the Nodal-related subclass of the TGF-β superfamily induce and pattern the mesoderm and endoderm in all vertebrates. In zebrafish, two nodal-related genes, called squint and cyclops, are required in a dosage-dependent manner for the formation of all derivatives of the mesoderm and endoderm. These genes are expressed dynamically during the blastula stages and may have different roles at different times. This question has been difficult to address because conditions that alter the timing of nodal-related gene expression also change Nodal levels. We utilized a pharmacological approach to conditionally inactivate the ALK 4, 5 and 7 receptors during the blastula stages without disturbing earlier signaling activity. This permitted us to directly examine when Nodal signals specify cell types independently of dosage effects. Results We show that two drugs, SB-431542 and SB-505124, completely block the response to Nodal signals when added to embryos after the mid-blastula transition. By blocking Nodal receptor activity at later stages, we demonstrate that Nodal signaling is required from the mid-to-late blastula period to specify sequentially, the somites, notochord, blood, Kupffer's vesicle, hatching gland, heart, and endoderm. Blocking Nodal signaling at late times prevents specification of cell types derived from the embryo margin, but not those from more animal regions. This suggests a linkage between cell fate and length of exposure to Nodal signals. Confirming this, cells exposed to a uniform Nodal dose adopt progressively more marginal fates with increasing lengths of exposure. Finally, cell fate specification is delayed in squint mutants and accelerated when Nodal levels are elevated. Conclusion We conclude that (1 Nodal signals are most active during the mid-to-late blastula stages, when nodal-related gene

  19. Physical activity and the pelvic floor.

    Science.gov (United States)

    Nygaard, Ingrid E; Shaw, Janet M

    2016-02-01

    Pelvic floor disorders are common, with 1 in 4 US women reporting moderate to severe symptoms of urinary incontinence, pelvic organ prolapse, or fecal incontinence. Given the high societal burden of these disorders, identifying potentially modifiable risk factors is crucial. Physical activity is one such potentially modifiable risk factor; the large number of girls and women participating in sport and strenuous training regimens increases the need to understand associated risks and benefits of these exposures. The aim of this review was to summarize studies reporting the association between physical activity and pelvic floor disorders. Most studies are cross-sectional and most include small numbers of participants. The primary findings of this review include that urinary incontinence during exercise is common and is more prevalent in women during high-impact sports. Mild to moderate physical activity, such as brisk walking, decreases both the odds of having and the risk of developing urinary incontinence. In older women, mild to moderate activity also decreases the odds of having fecal incontinence; however, young women participating in high-intensity activity are more likely to report anal incontinence than less active women. Scant data suggest that in middle-aged women, lifetime physical activity increases the odds of stress urinary incontinence slightly and does not increase the odds of pelvic organ prolapse. Women undergoing surgery for pelvic organ prolapse are more likely to report a history of heavy work than controls; however, women recruited from the community with pelvic organ prolapse on examination report similar lifetime levels of strenuous activity as women without this examination finding. Data are insufficient to determine whether strenuous activity while young predisposes to pelvic floor disorders later in life. The existing literature suggests that most physical activity does not harm the pelvic floor and does provide numerous health benefits for

  20. Total body irradiation

    International Nuclear Information System (INIS)

    Novack, D.H.; Kiley, J.P.

    1987-01-01

    The multitude of papers and conferences in recent years on the use of very large megavoltage radiation fields indicates an increased interest in total body, hemibody, and total nodal radiotherapy for various clinical situations. These include high dose total body irradiation (TBI) to destroy the bone marrow and leukemic cells and provide immunosuppression prior to a bone marrow transplant, high dose total lymphoid irradiation (TLI) prior to bone marrow transplantation in severe aplastic anemia, low dose TBI in the treatment of lymphocytic leukemias or lymphomas, and hemibody irradiation (HBI) in the treatment of advanced multiple myeloma. Although accurate provision of a specific dose and the desired degree of dose homogeneity are two of the physicist's major considerations for all radiotherapy techniques, these tasks are even more demanding for large field radiotherapy. Because most large field radiotherapy is done at an extended distance for complex patient geometries, basic dosimetry data measured at the standard distance (isocenter) must be verified or supplemented. This paper discusses some of the special dosimetric problems of large field radiotherapy, with specific examples given of the dosimetry of the TBI program for bone marrow transplant at the authors' hospital

  1. Use of CT simulation for treatment of cervical cancer to assess the adequacy of lymph node coverage of conventional pelvic fields based on bony landmarks

    International Nuclear Information System (INIS)

    Finlay, Marisa H.; Ackerman, Ida; Tirona, Romeo G. B.Sc.; Hamilton, Paul; Barbera, Lisa; Thomas, Gillian

    2006-01-01

    Purpose: To assess the adequacy of nodal coverage of 'conventional' pelvic radiation fields for carcinoma of the cervix, with contoured pelvic vessels on simulation computed tomography (CT) as surrogates for lymph node location. Methods and Materials: Pelvic arteries were contoured on non-contrast-enhanced CT simulation images of 43 patients with cervix cancer, FIGO Stages I-III. Vessel contours were hidden, and conventional pelvic fields were outlined: (1) anterior/posterior fields (AP): superior border, L5-S1 interspace; inferior border, obturator foramina; lateral border, 2 centimeters lateral to pelvic brim. (2) Lateral fields (LAT): Anterior border, symphysis pubis; posterior border, S2-S3 interspace. Distances were measured between the following: (1) bifurcation of the common iliac artery and superior border (2) external iliac artery and lateral border of the AP field, and (3) external iliac artery and anterior border of the LAT field. The distances were considered as 'inadequate' if 20 mm. Results: Superiorly, 34 patients (79.1%) had inadequate coverage. On the AP, margins were generous in 19 (44.2%), but inadequate in 9 (20.9%). On the LAT, margins were inadequate in 30 (69.8%) patients. Overall, 41 (95.4%, CI, 84.2%-99.4%) patients had at least 1 inadequate margin, the majority located superiorly. Twenty-four (55.8%; CI, 39.9%-70.9%) patients had at least 1 generous margin, the majority located laterally on the AP field. Conclusion: Conventional pelvic fields based on bony landmarks do not provide optimal lymph node coverage in a substantial proportion of patients and may include excess normal tissue in some. CT simulation with vessel contouring as a surrogate for lymph node localization provides more precise and individualized field delineation

  2. Exact boundary controllability of nodal profile for quasilinear hyperbolic systems

    CERN Document Server

    Li, Tatsien; Gu, Qilong

    2016-01-01

    This book provides a comprehensive overview of the exact boundary controllability of nodal profile, a new kind of exact boundary controllability stimulated by some practical applications. This kind of controllability is useful in practice as it does not require any precisely given final state to be attained at a suitable time t=T by means of boundary controls, instead it requires the state to exactly fit any given demand (profile) on one or more nodes after a suitable time t=T by means of boundary controls. In this book we present a general discussion of this kind of controllability for general 1-D first order quasilinear hyperbolic systems and for general 1-D quasilinear wave equations on an interval as well as on a tree-like network using a modular-structure construtive method, suggested in LI Tatsien's monograph "Controllability and Observability for Quasilinear Hyperbolic Systems"(2010), and we establish a complete theory on the local exact boundary controllability of nodal profile for 1-D quasilinear hyp...

  3. Nodal Diffusion Burnable Poison Treatment for Prismatic Reactor Cores

    International Nuclear Information System (INIS)

    Ougouag, A.M.; Ferrer, R.M.

    2010-01-01

    The prismatic block version of the High Temperature Reactor (HTR) considered as a candidate Very High Temperature Reactor (VHTR)design may use burnable poison pins in locations at some corners of the fuel blocks (i.e., assembly equivalent structures). The presence of any highly absorbing materials, such as these burnable poisons, within fuel blocks for hexagonal geometry, graphite-moderated High Temperature Reactors (HTRs) causes a local inter-block flux depression that most nodal diffusion-based method have failed to properly model or otherwise represent. The location of these burnable poisons near vertices results in an asymmetry in the morphology of the assemblies (or blocks). Hence the resulting inadequacy of traditional homogenization methods, as these 'spread' the actually local effect of the burnable poisons throughout the assembly. Furthermore, the actual effect of the burnable poison is primarily local with influence in its immediate vicinity, which happens to include a small region within the same assembly as well as similar regions in the adjacent assemblies. Traditional homogenization methods miss this artifact entirely. This paper presents a novel method for treating the local effect of the burnable poison explicitly in the context of a modern nodal method.

  4. Hereditary bone dysplasia with pathological fractures and nodal osteoarthropathy

    International Nuclear Information System (INIS)

    Arendse, Regan; Brink, Paul; Beighton, Peter

    2009-01-01

    A father and daughter both had multiple pathological fractures and nodal osteoarthropathy. The father, aged 50 years, had at least 20 healed fractures of the axial and appendicular skeleton, sustained by minor trauma over his 50-year lifespan, many of which had been surgically fixed prior to his first presentation to us. Fractures of the clavicles, thoracic cage and long bones of the arms and legs, had healed with malalignment and deformity. Healed fractures were complicated by ankylosis of the cervical vertebrae and both elbows. He also had osteoarthritis of the hands, with exuberant osteophytosis, and profound perceptive deafness. His general health was good, his intellect and facies were normal, and his sclerae were white. The daughter, aged 27 years, had sustained at least seven fractures of the axial and appendicular skeleton following trivial injuries, in distribution similar to those of the father. She had also experienced painful swelling of the fingers, which preceded progressive development of nodal osteoarthropathy. Her hearing was normal. In both individuals, biochemical and immunological investigations yielded normal results. It was not possible for molecular studies to be undertaken. Pedigree data were consistent with autosomal dominant transmission, and this disorder appeared to be a previously undocumented heritable skeletal dysplasia. (orig.)

  5. Hereditary bone dysplasia with pathological fractures and nodal osteoarthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Arendse, Regan [University of Stellenbosch, Department of Medicine, Tygerberg Hospital, Stellenbosch (South Africa); University of Cape Town, Division of Rheumatology, Groote Schuur Hospital, Cape Town (South Africa); Brink, Paul [University of Stellenbosch, Department of Medicine, Tygerberg Hospital, Stellenbosch (South Africa); Beighton, Peter [University of Cape Town, Division of Human Genetics, Faculty of Health Sciences, Cape Town (South Africa)

    2009-12-15

    A father and daughter both had multiple pathological fractures and nodal osteoarthropathy. The father, aged 50 years, had at least 20 healed fractures of the axial and appendicular skeleton, sustained by minor trauma over his 50-year lifespan, many of which had been surgically fixed prior to his first presentation to us. Fractures of the clavicles, thoracic cage and long bones of the arms and legs, had healed with malalignment and deformity. Healed fractures were complicated by ankylosis of the cervical vertebrae and both elbows. He also had osteoarthritis of the hands, with exuberant osteophytosis, and profound perceptive deafness. His general health was good, his intellect and facies were normal, and his sclerae were white. The daughter, aged 27 years, had sustained at least seven fractures of the axial and appendicular skeleton following trivial injuries, in distribution similar to those of the father. She had also experienced painful swelling of the fingers, which preceded progressive development of nodal osteoarthropathy. Her hearing was normal. In both individuals, biochemical and immunological investigations yielded normal results. It was not possible for molecular studies to be undertaken. Pedigree data were consistent with autosomal dominant transmission, and this disorder appeared to be a previously undocumented heritable skeletal dysplasia. (orig.)

  6. Dirac Magnon Nodal Loops in Quasi-2D Quantum Magnets.

    Science.gov (United States)

    Owerre, S A

    2017-07-31

    In this report, we propose a new concept of one-dimensional (1D) closed lines of Dirac magnon nodes in two-dimensional (2D) momentum space of quasi-2D quantum magnetic systems. They are termed "2D Dirac magnon nodal-line loops". We utilize the bilayer honeycomb ferromagnets with intralayer coupling J and interlayer coupling J L , which is realizable in the honeycomb chromium compounds CrX 3 (X ≡ Br, Cl, and I). However, our results can also exist in other layered quasi-2D quantum magnetic systems. Here, we show that the magnon bands of the bilayer honeycomb ferromagnets overlap for J L  ≠ 0 and form 1D closed lines of Dirac magnon nodes in 2D momentum space. The 2D Dirac magnon nodal-line loops are topologically protected by inversion and time-reversal symmetry. Furthermore, we show that they are robust against weak Dzyaloshinskii-Moriya interaction Δ DM  magnon edge modes.

  7. Transvaginal Ultrasound-Guided Aspiration of Pelvic Abscesses

    Directory of Open Access Journals (Sweden)

    P. J. Corsi

    1999-01-01

    Full Text Available Objective: To assess the utility of a less invasive approach to the care of women with a pelvic abscess, we retrospectively reviewed the outcome of women with pelvic abscesses managed by transvaginal ultrasound-guided aspiration.

  8. Pelvic Organ Prolapse in Jimma University Specialized Hospital ...

    African Journals Online (AJOL)

    Pelvic Organ Prolapse in Jimma University Specialized Hospital, Southwest Ethiopia. ... and there was a significant association between prolapse and residence area. ... Awareness creation on risk factors of pelvic organ prolapse and use of ...

  9. Symptomatic pelvic organ prolapse: Experience at a tertiary ...

    African Journals Online (AJOL)

    information was recorded after a detailed history, physical examination and completion of a self-administered symptom questionnaire. ... due to anatomical restoration of prolapse in ..... of terminology of female pelvic organ prolapse and pelvic.

  10. Imaging of the posterior pelvic floor

    International Nuclear Information System (INIS)

    Stoker, Jaap; Bartram, Clive I.; Halligan, Steve

    2002-01-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  11. Imaging of the posterior pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands); Bartram, Clive I.; Halligan, Steve [Intestinal Imaging Centre, St. Mark' s Hospital, London (United Kingdom)

    2002-04-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  12. Detection of lymph node metastasis in patients with nodal prostate cancer relapse using (18)F/(11)C-choline positron emission tomography/computerized tomography.

    Science.gov (United States)

    Jilg, Cordula A; Schultze-Seemann, Wolfgang; Drendel, Vanessa; Vach, Werner; Wieser, Gesche; Krauss, Tobias; Jandausch, Anett; Hölz, Stefanie; Henne, Karl; Reske, Sven N; Grosu, Anca-L; Weber, Wolfgang A; Rischke, H Christian

    2014-07-01

    We evaluated the diagnostic accuracy of choline positron emission tomography/computerized tomography for nodal relapse of prostate cancer according to topographical site and tumor infiltration size in lymph nodes. A total of 72 patients with nodal prostate cancer relapse after primary therapy underwent pelvic and/or retroperitoneal salvage lymph node dissection. Salvage was done after whole body positron emission tomography/computerized tomography with (11)C-choline or (18)F-fluoroethylcholine showed positron emission tomography positive lymph nodes but no other detectable metastasis. Diagnostic accuracy was evaluated in 160 dissected lymph node regions (pelvic left/right and retroperitoneal), 498 subregions (common, external and internal iliac, obturator, presacral, aortic bifurcation, aortal, vena caval and interaortocaval) and 2,122 lymph nodes. Lymph node metastasis was present in 32% of resected lymph nodes (681 of 2,122), resulting in 238 positive subregions and 111 positive regions. Positron emission tomography/computerized tomography was positive for 110 regions and 209 subregions. Sensitivity, specificity, positive and negative predictive values, and accuracy were 91.9%, 83.7%, 92.7%, 82.0% and 89.4% (region based), 80.7%, 93.5%, 91.9%, 84.1% and 87.3% (subregion based), and 57.0%, 98.4%, 94.5%, 82.6% and 84.9% (lesion based), respectively. Of 393 positive lymph node metastases detected by this method 278 (70.7%) were in lymph nodes with a less than 10 mm short axis diameter. Imaging sensitivity was 13.3%, 57.4% and 82.8% for a tumor infiltration depth of 2 or greater to less than 3 mm, 5 or greater to less than 6 mm and 10 or greater to less than 11 mm, respectively. Lymph node metastasis site and the radiotracer ((11)C-choline/(18)F-fluoroethylcholine) had no substantial impact on diagnostic accuracy. Choline positron emission tomography/computerized tomography detects affected lymph node regions (pelvic left/right and retroperitoneal) in patients with

  13. Laparoendoscopic single site in pelvic surgery

    Science.gov (United States)

    Sanchez-Salas, Rafael; Clavijo, Rafael; Barret, Eric; Sotelo, Rene

    2012-01-01

    Laparoendoscopic single site (LESS) has recently gained momentum as feasible techniques for minimal access surgery. Our aim is to describe the current status of laparoendoscopic single site (LESS) in pelvic surgery. A comprehensive revision of the literature in LESS pelvic surgery was performed. References for this manuscript were obtained by performing a review of the available literature in PubMed from 01-01-01 to 30-11-11. References outside the search period were obtained selected manuscript΄s bibliography. Search terms included: pelvic anatomy, less in gynecology, single port colectomy, urological less, single port, single site, NOTES, LESS and single incision. 314 manuscripts were initially identified. Out of these, 46 manuscripts were selected based in their pelvic anatomy or surgical content; including experimental experience, clinical series and literature reviews. LESS drastically limit the surgeon's ability to perform in the operative field and the latter becomes hardened by the lack of space in anatomical location like the pelvis. Potential advantages of LESS are gained with the understanding that the surgical procedure is more technically challenging. Pelvic surgical procedures related to colorectal surgery, gynecology and urology have been performed with LESS technique and information available is mostly represented by case reports and short case series. Comparative series remain few. LESS pelvic surgery remain in its very beginning and due to the very specific anatomical conditions further development of LESS surgery in the mentioned area can be clearly be facilitated by using robotic technology. Standardization ad reproducibility of techniques are mandatory to further develop LESS in the surgical arena.. PMID:22557719

  14. Laparoendoscopic single site in pelvic surgery

    Directory of Open Access Journals (Sweden)

    Rafael Sanchez-Salas

    2012-01-01

    Full Text Available Laparoendoscopic single site (LESS has recently gained momentum as feasible techniques for minimal access surgery. Our aim is to describe the current status of laparoendoscopic single site (LESS in pelvic surgery. A comprehensive revision of the literature in LESS pelvic surgery was performed. References for this manuscript were obtained by performing a review of the available literature in PubMed from 01-01-01 to 30-11-11. References outside the search period were obtained selected manuscript΄s bibliography. Search terms included: pelvic anatomy, less in gynecology, single port colectomy, urological less, single port, single site, NOTES, LESS and single incision. 314 manuscripts were initially identified. Out of these, 46 manuscripts were selected based in their pelvic anatomy or surgical content; including experimental experience, clinical series and literature reviews. LESS drastically limit the surgeon′s ability to perform in the operative field and the latter becomes hardened by the lack of space in anatomical location like the pelvis. Potential advantages of LESS are gained with the understanding that the surgical procedure is more technically challenging. Pelvic surgical procedures related to colorectal surgery, gynecology and urology have been performed with LESS technique and information available is mostly represented by case reports and short case series. Comparative series remain few. LESS pelvic surgery remain in its very beginning and due to the very specific anatomical conditions further development of LESS surgery in the mentioned area can be clearly be facilitated by using robotic technology. Standardization ad reproducibility of techniques are mandatory to further develop LESS in the surgical arena..

  15. Functional imaging of the pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Lienemann, Andreas E-mail: andreaslienemann@web.de; Fischer, Tanja

    2003-08-01

    Introduction/Objective: Pelvic floor dysfunction and associated pelvic organ prolapse represent a major problem in our present-day society, mostly afflicting parous women. Magnetic resonance imaging (MRI) is assuming an increasingly important role in the more accurate delineation of the extent of the problem. This article briefly reviews one of the main radiological methods for the dynamic evaluation of the pelvic floor: functional cine MRI. Methods and Material: Out of the literature the smallest common denominator for functional cine MRI can be defined as follows: high field system; patient either in supine or sitting position; fast gradient echo sequence; midsagittal slice orientation; either a stack of slices or repeated measurements at the same slice position with the patient at rest or straining; image analysis using the pubococcygeal reference line. Results: All except two publications stress the usefulness of functional cine MRI in the evaluation of patients with organ descent and prolapse. This well accepted method allows for the visualization of all relevant structures in the anterior, middle and posterior compartment. It is especially useful in the detection of enteroceles, and provides a reliable postoperative follow-up tool. Isolated urinary or stool incontinence are not an indication for functional cine MRI, as is the case in patients with equivocal clinical findings. To date it does not allow for real 3D imaging of the pelvic floor or sufficient determination of fascial defects. Discussion: Functional cine MRI of the pelvic floor is a promising new imaging method for the detection of organ descent and prolapse in patients with equivocal clinical findings. The combination of function and morphology allows for an innovative view of the pelvic floor, and thus adds to our understanding of the various interactions of the structures.

  16. [Quality of life after extensive pelvic surgery].

    Science.gov (United States)

    Levý, M; Lipská, L; Visokai, V; Šimša, J

    Multiorgan resections in the small pelvis are standard procedures in oncosurgery and some indications have no alternative. In advanced pelvic cancer, pelvic exenteration with en bloc resection of the involved organs and structures, including portions of the bony pelvis, is indicated. The 5-year survival rate is fairly good, around 50%, but little is known about the long-term quality of life. The aim was to describe the quality of life of long-term total pelvic exenteration survivors. In total, 63 pelvic exenterations were performed between 2000 to 2015 at the Department of Surgery, Thomayer Hospital, First Faculty of Medicine, Charles University in Prague, mostly for primary or relapsed rectal cancer. In this retrospective cohort study, the quality of life was assessed using the EORTC QLQ-C30 (version 3.0) and the EORTC QLQ-CR29 questionnaires. The completed questionnaires were scored according to EORTC instructions. At the time of this survey, 24 patients after TPE were surviving longer than one year after the surgery. The five-year survival of all patients was 49%, median survival 4.6 years, and median follow-up 15 months. Most of our patients reported a good level of their physical, emotional, cognitive and social functions. Some patients reported a worse body image, and of course a worsening in their sexual life. Regarding symptom-oriented questions, some patients evaluated the necessity of more frequent care of the stomia as slightly problematic; most patients reported impotence (men) or painful sexual intercourse (women). Long-term quality of life in survivors of pelvic exenteration for rectal cancer is comparable with reported results following primary rectal cancer resection with the exception of the sexual function. The quality of life gradually improves in the course of weeks to months from the surgery. pelvic exenteration quality of life.

  17. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    International Nuclear Information System (INIS)

    Lagisetty, Jyothi; Slovis, Thomas; Thomas, Ronald; Knazik, Stephen; Stankovic, Curt

    2012-01-01

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS <14, positive urinalysis, abdominal pain/tenderness, femur fracture) and five high-risk mechanisms of injury (unrestrained motor vehicle collision [MVC], MVC with ejection, MVC rollover, auto vs. pedestrian, auto vs. bicycle). Pelvic fractures in pediatric major blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients. (orig.)

  18. Knowledge of the pelvic floor in nulliparous women

    OpenAIRE

    Neels, Hedwig; Wyndaele, Jean-Jacques; Tjalma, Wiebren A. A.; De Wachter, Stefan; Wyndaele, Michel; Vermandel, Alexandra

    2016-01-01

    [Purpose] Proper pelvic floor function is important to avoid serious dysfunctions including incontinence, prolapse, and sexual problems. The current study evaluated the knowledge of young nulliparous women about their pelvic floor and identified what additional information they wanted. [Subjects and Methods] In this cross-sectional survey, a validated, 36 item questionnaire was distributed to 212 nulliparous women. The questionnaire addressed demography, pelvic floor muscles, pelvic floor dys...

  19. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Lagisetty, Jyothi [Memorial Hermann Medical Center, Emergency Medicine Department, Houston, TX (United States); Slovis, Thomas [Wayne State University School of Medicine, Department of Radiology, Pediatric Imaging, Children' s Hospital of Michigan, Detroit, MI (United States); Thomas, Ronald [Children' s Hospital of Michigan, Wayne State University of Medicine, Department of Pediatrics, Detroit, MI (United States); Knazik, Stephen; Stankovic, Curt [Wayne State University of Medicine, Division of Emergency Medicine, Children' s Hospital of Michigan, Detroit, MI (United States)

    2012-07-15

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS <14, positive urinalysis, abdominal pain/tenderness, femur fracture) and five high-risk mechanisms of injury (unrestrained motor vehicle collision [MVC], MVC with ejection, MVC rollover, auto vs. pedestrian, auto vs. bicycle). Pelvic fractures in pediatric major blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients. (orig.)

  20. Incidence of isolated nodal failure in non-small cell lung cancer patients included in a prospective study of the value of PET–CT

    International Nuclear Information System (INIS)

    Kolodziejczyk, Milena; Bujko, Krzysztof; Michalski, Wojciech; Kepka, Lucyna

    2012-01-01

    Purpose: Elective nodal irradiation (ENI) is not recommended in PET–CT-based radiotherapy for NSCLC despite a low level of evidence to support such guidelines. The aim of this investigation is to find out whether omitting ENI is safe. Materials and methods: Sixty-seven patients treated within a frame of a previously published prospective trial of the value of PET–CT were included in the analysis. Seventeen (25%) patients received ENI due to higher initial nodal involvement and in the remaining 50 patients (75%) with N0-N1 or single N2 disease ENI was omitted. Isolated nodal failure (INF) was recorded if relapse occurred in the initially uninvolved regional lymph node without previous or simultaneous local recurrence regardless of the status of distant metastases. Results: With a median follow-up of 32 months, the estimated 3-year overall survival was 42%, local progression-free interval was 55%, and distant metastases-free interval was 62%. Three patients developed INF; all had ENI omitted from treatment, giving a final result of three INFs in 50 (6%) patients treated without ENI. In this group of patients, the 3-year cause-specific cumulative incidence of INF was 6.4% (95% confidence interval: 0–17%). Conclusions: The omission of ENI appears to be not as safe as suggested by current recommendations.

  1. Incidence of isolated nodal failure in non-small cell lung cancer patients included in a prospective study of the value of PET-CT.

    Science.gov (United States)

    Kolodziejczyk, Milena; Bujko, Krzysztof; Michalski, Wojciech; Kepka, Lucyna

    2012-07-01

    Elective nodal irradiation (ENI) is not recommended in PET-CT-based radiotherapy for NSCLC despite a low level of evidence to support such guidelines. The aim of this investigation is to find out whether omitting ENI is safe. Sixty-seven patients treated within a frame of a previously published prospective trial of the value of PET-CT were included in the analysis. Seventeen (25%) patients received ENI due to higher initial nodal involvement and in the remaining 50 patients (75%) with N0-N1 or single N2 disease ENI was omitted. Isolated nodal failure (INF) was recorded if relapse occurred in the initially uninvolved regional lymph node without previous or simultaneous local recurrence regardless of the status of distant metastases. With a median follow-up of 32 months, the estimated 3-year overall survival was 42%, local progression-free interval was 55%, and distant metastases-free interval was 62%. Three patients developed INF; all had ENI omitted from treatment, giving a final result of three INFs in 50 (6%) patients treated without ENI. In this group of patients, the 3-year cause-specific cumulative incidence of INF was 6.4% (95% confidence interval: 0-17%). The omission of ENI appears to be not as safe as suggested by current recommendations. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Abdominal and pelvic lymph node involvement in non-Hodgkin lymphoma: CT manifestations in Chinese patients

    International Nuclear Information System (INIS)

    Wu Ning; Liu Ying; Chen Yu; Lin Dongmei; Shi Mulan

    2004-01-01

    Objective: To study the CT manifestations of abdominal and pelvic lymph nodes in non- Hodgkin lymphoma (NHL) of Chinese patients, and to investigate their correlation with pathology subtypes. Methods: The CT images of 241 patients with enlargement of abdominal and pelvic lymph nodes involved by NHL were reviewed. Of them, 96 patients whose clinical and imaging data fulfilled the requirement for analysis were included. According to the Clinical Schema for the Lymphoid System, patients were divided into 3 subtypes, indolent lymphoma (IL; n=31), aggressive lymphoma (AL; n=61), very aggressive lymphoma (VAL; n=2), and unclassified lymphoma (UCL; n=2), respectively. Abdominal and pelvic CT scans were undertaken in 46 patients, abdominal CT only in 47 cases, and pelvic CT only in 3 cases. CT with iv contrast administration was obtained in 80 patients. Anatomic sites involved were nominated as retroperitoneal (i.e. paraaortic), abdominal (including paracardiac, gastrohepatic, hepatic hilar, and mesenteric etc), retrocrural, diaphragmatic, common iliac, internal iliac, external iliac, and inguinal nodes, respectively. Size, number, discreteness, and density of the nodal lesions were analyzed, and correlated with pathology subtypes. The minimal dimension of the largest node was measured. Results: (1) Size: Most of the nodes were ≤2 cm in size, 60.5% (219/362 sites) in IL and AL, 56.6% (77/136 sites) in IL, and 62.8%(142/226 sites) in AL, respectively. There was no statistical significant difference of the nodal size between IL and AL in each location (χ 2 =0.341, P=0.559). (2) Number: Mesentery had the largest number of node involvement (6.5 vs 5 nodes on an median, IL vs AL), with retroperitoneum placed second (4 vs 4 nodes, IL vs AL. (3) Discreteness: Most of the nodes were discrete with an incidence of 77.1% (279/362 sites, IL and AL), and 74.3% (101/136 sites) in IL, 78.8% (178/226 sites) in AL, respectively. No statistical significant discrepancy was found between

  3. Primary Pelvic Involvement of Hydatid Disease

    Directory of Open Access Journals (Sweden)

    Migraci Tosun

    2011-04-01

    Full Text Available Hydatid disease is caused by larval stage of a parasite named as Echinococcus. To diagnose this condition may be challenging without surgery and postoperative pathological examination due to limited value of serological studies but imaging techniques may give a clue when hydatid disease is suspected and hydatid disease shall be considered for differential diagnosis in pelvic mass. In the present case, we present a 75-year-old postmenopausal woman with pelvic hydatosis.

  4. Pelvic radiograph in skeletal dysplasias: An approach

    Directory of Open Access Journals (Sweden)

    Manisha Jana

    2017-01-01

    Full Text Available The bony pelvis is constituted by the ilium, ischium, pubis, and sacrum. The pelvic radiograph is an important component of the skeletal survey performed in suspected skeletal dysplasia. Most of the common skeletal dysplasias have either minor or major radiological abnormalities; hence, knowledge of the normal radiological appearance of bony pelvis is vital for recognizing the early signs of various skeletal dysplasias. This article discusses many common and some uncommon radiological findings on pelvic radiographs along with the specific dysplasia in which they are seen; common differential diagnostic considerations are also discussed.

  5. US and MR imaging of pelvic masses

    International Nuclear Information System (INIS)

    Angtuaco, T.L.; Boyd, C.M.; Mattison, D.R.; Williamson, M.R.; Sanders, M.M.; Bard, D.S.

    1987-01-01

    US and MR imaging were compared in benign and malignant pelvic masses to determine where MR imaging may replace US. With regard to benign masses, MR imaging showed a significant advantage only in the imaging of teratomas. In malignancy, US was better than MR imaging in delineating internal architecture. MR imaging was superior in suggesting the origin and extent of masses, especially in large neoplasms. US remains a reliable tool in the initial evaluation of pelvic masses. When US studies are suboptimal, MR imaging should be performed as complementary study. MR imaging may replace US in the initial examination of large masses where US cannot depict the origin and extent

  6. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.

    Science.gov (United States)

    Schwarz, Timo Julian; Weber, Markus; Dornia, Christian; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Craiovan, Benjamin

    2017-09-01

    Purpose  Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method  In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results  The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion  Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points   · Pelvic tilt and rotation influence cup

  7. Assessment of Effect on LBLOCA PCT for Change in Upper Head Nodalization

    International Nuclear Information System (INIS)

    Kang, Dong Gu; Huh, Byung Gil; Yoo, Seung Hun; Bang, Youngseok; Seul, Kwangwon; Cho, Daehyung

    2014-01-01

    In this study, the best estimate plus uncertainty (BEPU) analysis of LBLOCA for original and modified nodalizations was performed, and the effect on LBLOCA PCT for change in upper head nodalization was assessed. In this study, the best estimate plus uncertainty (BEPU) analysis of LBLOCA for original and modified nodalizations was performed, and the effect on LBLOCA PCT for change in upper head nodalization was assessed. It is confirmed that modification of upper head nodalization influences PCT behavior, especially in the reflood phase. In conclusions, the modification of nodalization to reflect design characteristic of upper head temperature should be done to predict PCT behavior accurately in LBLOCA analysis. In the best estimate (BE) method with the uncertainty evaluation, the system nodalization is determined by the comparative studies of the experimental data. Up to now, it was assumed that the temperature of the upper dome in OPR-1000 was close to that of the cold leg. However, it was found that the temperature of the upper head/dome might be a little lower than or similar to that of the hot leg through the evaluation of the detailed design data. Since the higher upper head temperature affects blowdown quenching and peak cladding temperature in the reflood phase, the nodalization for upper head should be modified

  8. LOLA SYSTEM: A code block for nodal PWR simulation. Part. I - Simula-3 Code

    Energy Technology Data Exchange (ETDEWEB)

    Aragones, J M; Ahnert, C; Gomez Santamaria, J; Rodriguez Olabarria, I

    1985-07-01

    Description of the theory and users manual of the SIMULA-3 code, which is part of the core calculation system by nodal theory in one group, called LOLA SYSTEM. SIMULA-3 is the main module of the system, it uses a modified nodal theory, with interface leakages equivalent to the diffusion theory. (Author) 4 refs.

  9. Rules for Phase Shifts of Quantum Oscillations in Topological Nodal-Line Semimetals

    Science.gov (United States)

    Li, Cequn; Wang, C. M.; Wan, Bo; Wan, Xiangang; Lu, Hai-Zhou; Xie, X. C.

    2018-04-01

    Nodal-line semimetals are topological semimetals in which band touchings form nodal lines or rings. Around a loop that encloses a nodal line, an electron can accumulate a nontrivial π Berry phase, so the phase shift in the Shubnikov-de Haas (SdH) oscillation may give a transport signature for the nodal-line semimetals. However, different experiments have reported contradictory phase shifts, in particular, in the WHM nodal-line semimetals (W =Zr /Hf , H =Si /Ge , M =S /Se /Te ). For a generic model of nodal-line semimetals, we present a systematic calculation for the SdH oscillation of resistivity under a magnetic field normal to the nodal-line plane. From the analytical result of the resistivity, we extract general rules to determine the phase shifts for arbitrary cases and apply them to ZrSiS and Cu3 PdN systems. Depending on the magnetic field directions, carrier types, and cross sections of the Fermi surface, the phase shift shows rich results, quite different from those for normal electrons and Weyl fermions. Our results may help explore transport signatures of topological nodal-line semimetals and can be generalized to other topological phases of matter.

  10. Nodal integral method for the neutron diffusion equation in cylindrical geometry

    International Nuclear Information System (INIS)

    Azmy, Y.Y.

    1987-01-01

    The nodal methodology is based on retaining a higher a higher degree of analyticity in the process of deriving the discrete-variable equations compared to conventional numerical methods. As a result, extensive numerical testing of nodal methods developed for a wide variety of partial differential equations and comparison of the results to conventional methods have established the superior accuracy of nodal methods on coarse meshes. Moreover, these tests have shown that nodal methods are more computationally efficient than finite difference and finite-element methods in the sense that they require shorter CPU times to achieve comparable accuracy in the solutions. However, nodal formalisms and the final discrete-variable equations they produce are, in general, more complicated than their conventional counterparts. This, together with anticipated difficulties in applying the transverse-averaging procedure in curvilinear coordinates, has limited the applications of nodal methods, so far, to Cartesian geometry, and with additional approximations to hexagonal geometry. In this paper the authors report recent progress in deriving and numerically implementing a nodal integral method (NIM) for solving the neutron diffusion equation in cylindrical r-z geometry. Also, presented are comparisons of numerical solutions to two test problems with those obtained by the Exterminator-2 code, which indicate the superior accuracy of the nodal integral method solutions on much coarser meshes

  11. LOLA SYSTEM: A code block for nodal PWR simulation. Part. I - Simula-3 Code

    International Nuclear Information System (INIS)

    Aragones, J. M.; Ahnert, C.; Gomez Santamaria, J.; Rodriguez Olabarria, I.

    1985-01-01

    Description of the theory and users manual of the SIMULA-3 code, which is part of the core calculation system by nodal theory in one group, called LOLA SYSTEM. SIMULA-3 is the main module of the system, it uses a modified nodal theory, with interface leakages equivalent to the diffusion theory. (Author) 4 refs

  12. A practical implementation of the higher-order transverse-integrated nodal diffusion method

    International Nuclear Information System (INIS)

    Prinsloo, Rian H.; Tomašević, Djordje I.; Moraal, Harm

    2014-01-01

    Highlights: • A practical higher-order nodal method is developed for diffusion calculations. • The method resolves the issue of the transverse leakage approximation. • The method achieves much superior accuracy as compared to standard nodal methods. • The calculational cost is only about 50% greater than standard nodal methods. • The method is packaged in a module for connection to existing nodal codes. - Abstract: Transverse-integrated nodal diffusion methods currently represent the standard in full core neutronic simulation. The primary shortcoming of this approach is the utilization of the quadratic transverse leakage approximation. This approach, although proven to work well for typical LWR problems, is not consistent with the formulation of nodal methods and can cause accuracy and convergence problems. In this work, an improved, consistent quadratic leakage approximation is formulated, which derives from the class of higher-order nodal methods developed some years ago. Further, a number of iteration schemes are developed around this consistent quadratic leakage approximation which yields accurate node average results in much improved calculational times. The most promising of these iteration schemes results from utilizing the consistent leakage approximation as a correction method to the standard quadratic leakage approximation. Numerical results are demonstrated on a set of benchmark problems and further applied to a realistic reactor problem, particularly the SAFARI-1 reactor, operating at Necsa, South Africa. The final optimal solution strategy is packaged into a standalone module which may simply be coupled to existing nodal diffusion codes

  13. Pelvic floor function during and after first pregnancy

    NARCIS (Netherlands)

    Brummen, H.J. van

    2006-01-01

    This study evaluated the effects the first pregnancy and childbirth on the pelvic floor. Pregnancy and vaginal delivery can negatively affect pelvic floor function. Micturition symptoms, defecation symptoms and sexual dysfunction are all signs of an impaired pelvic floor function. These symptoms are

  14. Opposing nodal and BMP signals regulate left-right asymmetry in the sea urchin larva.

    Directory of Open Access Journals (Sweden)

    Yi-Jyun Luo

    Full Text Available Nodal and BMP signals are important for establishing left-right (LR asymmetry in vertebrates. In sea urchins, Nodal signaling prevents the formation of the rudiment on the right side. However, the opposing pathway to Nodal signaling during LR axis establishment is not clear. Here, we revealed that BMP signaling is activated in the left coelomic pouch, specifically in the veg2 lineage, but not in the small micromeres. By perturbing BMP activities, we demonstrated that BMP signaling is required for activating the expression of the left-sided genes and the formation of the left-sided structures. On the other hand, Nodal signals on the right side inhibit BMP signaling and control LR asymmetric separation and apoptosis of the small micromeres. Our findings show that BMP signaling is the positive signal for left-sided development in sea urchins, suggesting that the opposing roles of Nodal and BMP signals in establishing LR asymmetry are conserved in deuterostomes.

  15. A spectral nodal method for discrete ordinates problems in x,y geometry

    International Nuclear Information System (INIS)

    Barros, R.C. de; Larsen, E.W.

    1991-06-01

    A new nodal method is proposed for the solution of S N problems in x- y-geometry. This method uses the Spectral Green's Function (SGF) scheme for solving the one-dimensional transverse-integrated nodal transport equations with no spatial truncation error. Thus, the only approximations in the x, y-geometry nodal method occur in the transverse leakage terms, as in diffusion theory. We approximate these leakage terms using a flat or constant approximation, and we refer to the resulting method as the SGF-Constant Nodal (SGF-CN) method. We show in numerical calculations that the SGF-CN method is much more accurate than other well-known transport nodal methods for coarse-mesh deep-penetration S N problems, even though the transverse leakage terms are approximated rather simply. (author)

  16. Dual Atrioventricular Nodal Pathways Physiology: A Review of Relevant Anatomy, Electrophysiology, and Electrocardiographic Manifestations

    Directory of Open Access Journals (Sweden)

    Bhalaghuru Chokkalingam Mani, MD

    2014-01-01

    Full Text Available More than half a century has passed since the concept of dual atrioventricular (AV nodal pathways physiology was conceived. Dual AV nodal pathways have been shown to be responsible for many clinical arrhythmia syndromes, most notably AV nodal reentrant tachycardia. Although there has been a considerable amount of research on this topic, the subject of dual AV nodal pathways physiology remains heavily debated and discussed. Despite advances in understanding arrhythmia mechanisms and the widespread use of invasive electrophysiologic studies, there is still disagreement on the anatomy and physiology of the AV node that is the basis of discontinuous antegrade AV conduction. The purpose of this paper is to review the concept of dual AV nodal pathways physiology and its varied electrocardiographic manifestations.

  17. Implications of improved diagnostic imaging of small nodal metastases in head and neck cancer: Radiotherapy target volume transformation and dose de-escalation.

    Science.gov (United States)

    van den Bosch, Sven; Vogel, Wouter V; Raaijmakers, Cornelis P; Dijkema, Tim; Terhaard, Chris H J; Al-Mamgani, Abrahim; Kaanders, Johannes H A M

    2018-05-03

    Diagnostic imaging continues to evolve, and now has unprecedented accuracy for detecting small nodal metastasis. This influences the tumor load in elective target volumes and subsequently has consequences for the radiotherapy dose required to control disease in these volumes. Small metastases that used to remain subclinical and were included in elective volumes, will nowadays be detected and included in high-dose volumes. Consequentially, high-dose volumes will more often contain low-volume disease. These target volume transformations lead to changes in the tumor burden in elective and "gross" tumor volumes with implications for the radiotherapy dose prescribed to these volumes. For head and neck tumors, nodal staging has evolved from mere palpation to combinations of high-resolution imaging modalities. A traditional nodal gross tumor volume in the neck typically had a minimum diameter of 10-15 mm, while nowadays much smaller tumor deposits are detected in lymph nodes. However, the current dose levels for elective nodal irradiation were empirically determined in the 1950s, and have not changed since. In this report the radiobiological consequences of target volume transformation caused by modern imaging of the neck are evaluated, and theoretically derived reductions of dose in radiotherapy for head and neck cancer are proposed. The concept of target volume transformation and subsequent strategies for dose adaptation applies to many other tumor types as well. Awareness of this concept may result in new strategies for target definition and selection of dose levels with the aim to provide optimal tumor control with less toxicity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    Science.gov (United States)

    Lagisetty, Jyothi; Slovis, Thomas; Thomas, Ronald; Knazik, Stephen; Stankovic, Curt

    2012-07-01

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients.

  19. Radiographic cup anteversion measurement corrected from pelvic tilt.

    Science.gov (United States)

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. An integral nodal variational method for multigroup criticality calculations

    International Nuclear Information System (INIS)

    Lewis, E.E.; Tsoulfanidis, N.

    2003-01-01

    An integral formulation of the variational nodal method is presented and applied to a series of benchmark critically problems. The method combines an integral transport treatment of the even-parity flux within the spatial node with an odd-parity spherical harmonics expansion of the Lagrange multipliers at the node interfaces. The response matrices that result from this formulation are compatible with those in the VARIANT code at Argonne National Laboratory. Either homogeneous or heterogeneous nodes may be employed. In general, for calculations requiring higher-order angular approximations, the integral method yields solutions with comparable accuracy while requiring substantially less CPU time and memory than the standard spherical harmonics expansion using the same spatial approximations. (author)

  1. An Adaptive Approach to Variational Nodal Diffusion Problems

    International Nuclear Information System (INIS)

    Zhang Hui; Lewis, E.E.

    2001-01-01

    An adaptive grid method is presented for the solution of neutron diffusion problems in two dimensions. The primal hybrid finite elements employed in the variational nodal method are used to reduce the diffusion equation to a coupled set of elemental response matrices. An a posteriori error estimator is developed to indicate the magnitude of local errors stemming from the low-order elemental interface approximations. An iterative procedure is implemented in which p refinement is applied locally by increasing the polynomial order of the interface approximations. The automated algorithm utilizes the a posteriori estimator to achieve local error reductions until an acceptable level of accuracy is reached throughout the problem domain. Application to a series of X-Y benchmark problems indicates the reduction of computational effort achievable by replacing uniform with adaptive refinement of the spatial approximations

  2. A nonlinear analytic function expansion nodal method for transient calculations

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Han Gyn; Park, Sang Yoon; Cho, Byung Oh; Zee, Sung Quun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    The nonlinear analytic function expansion nodal (AFEN) method is applied to the solution of the time-dependent neutron diffusion equation. Since the AFEN method requires both the particular solution and the homogeneous solution to the transient fixed source problem, the derivation of the solution method is focused on finding the particular solution efficiently. To avoid complicated particular solutions, the source distribution is approximated by quadratic polynomials and the transient source is constructed such that the error due to the quadratic approximation is minimized, In addition, this paper presents a new two-node solution scheme that is derived by imposing the constraint of current continuity at the interface corner points. The method is verified through a series of application to the NEACRP PWR rod ejection benchmark problems. 6 refs., 2 figs., 1 tab. (Author)

  3. On-line application of the PANTHER advanced nodal code

    International Nuclear Information System (INIS)

    Hutt, P.K.; Knight, M.P.

    1992-01-01

    Over the last few years, Nuclear Electric has developed an integrated core performance code package for both light water reactors (LWRs) and advanced gas-cooled reactors (AGRs) that can perform a comprehensive range of calculations for fuel cycle design, safety analysis, and on-line operational support for such plants. The package consists of the following codes: WIMS for lattice physics, PANTHER whole reactor nodal flux and AGR thermal hydraulics, VIPRE for LWR thermal hydraulics, and ENIGMA for fuel performance. These codes are integrated within a UNIX-based interactive system called the Reactor Physics Workbench (RPW), which provides an interactive graphic user interface and quality assurance records/data management. The RPW can also control calculational sequences and data flows. The package has been designed to run both off-line and on-line accessing plant data through the RPW

  4. Fourier-Accelerated Nodal Solvers (FANS) for homogenization problems

    Science.gov (United States)

    Leuschner, Matthias; Fritzen, Felix

    2017-11-01

    Fourier-based homogenization schemes are useful to analyze heterogeneous microstructures represented by 2D or 3D image data. These iterative schemes involve discrete periodic convolutions with global ansatz functions (mostly fundamental solutions). The convolutions are efficiently computed using the fast Fourier transform. FANS operates on nodal variables on regular grids and converges to finite element solutions. Compared to established Fourier-based methods, the number of convolutions is reduced by FANS. Additionally, fast iterations are possible by assembling the stiffness matrix. Due to the related memory requirement, the method is best suited for medium-sized problems. A comparative study involving established Fourier-based homogenization schemes is conducted for a thermal benchmark problem with a closed-form solution. Detailed technical and algorithmic descriptions are given for all methods considered in the comparison. Furthermore, many numerical examples focusing on convergence properties for both thermal and mechanical problems, including also plasticity, are presented.

  5. Nodal domains on isospectral quantum graphs: the resolution of isospectrality?

    International Nuclear Information System (INIS)

    Band, Ram; Shapira, Talia; Smilansky, Uzy

    2006-01-01

    We present and discuss isospectral quantum graphs which are not isometric. These graphs are the analogues of the isospectral domains in R 2 which were introduced recently in Gordon et al (1992 Bull. Am. Math. Soc. 27 134-8), Chapman (1995 Am. Math. Mon. 102 124), Buser et al (1994 Int. Math. Res. Not. 9 391-400), Okada and Shudo (2001 J. Phys. A: Math. Gen. 34 5911-22), Jakobson et al (2006 J. Comput. Appl. Math. 194 141-55) and Levitin et al (2006 J. Phys. A: Math. Gen. 39 2073-82)) all based on Sunada's construction of isospectral domains (Sunada T 1985 Ann. Math. 121 196-86). After presenting some of the properties of these graphs, we discuss a few examples which support the conjecture that by counting the nodal domains of the corresponding eigenfunctions one can resolve the isospectral ambiguity

  6. INTERMITTENT ANTIARYTHMIC THERAPY OF ARIOVENTICULAR NODAL REENTRY TACHYCARDIA IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Boris Djindjic

    2008-04-01

    Full Text Available Until recent advances in pharmacology and clinical cardiology regarding farmacodynamics of antiarrhythmic drugs and their efficiency in patients with refractory paroxysmal supraventricular tachycardia, chronic prophylactic therapy was the only treatment option for patients refusing catheter ablation. Another treatment option, also known by eponym “pill in pocket” have been shown to be equally useful and efficacious.The aim of our study was prospective examination of children with refractory atrioventricular nodal reentry tachycardia (AVNRT who were withdrawn from chronic antiarrhythmic prophylactic therapy and started with intermittent oral beta blocker treatment (propranolol at dosage 1 mg/kg - max 80 mg.Twelve children (8 boys and 4 girls with AVNRT were included in the study. Four children did not have arrhythmia during first six months after withdrawal and 7 were successfully treated without complication.Intermittent antiarrhythmic therapy in children with AVNRT could be very efficacious and useful treatment option which significantly improves their quality of life.

  7. CAISO flicks switch on nodal scheme and lights stay on

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-06-15

    In 2000-01, two years after introducing a competitive wholesale power auction in California - with a separate day-ahead zonal market operated by the California Power Exchange and a zonal market for ancillary services and balancing energy operated by the California Independent System Operator (CAISO) - the California market collapsed from exorbitant prices, flagrant gaming, and abuse of market power. Nine years later, CAISO introduced a nodal pricing auction for the wholesale market in April, replacing the zonal scheme, which was among many causes of the original market's demise. With nearly 3,000 nodes on the network, high prices in one region do not affect prices everywhere on the system. After investing some $200 million to upgrade the software, countless delays, and 18 months of market simulation and testing, the new auction was introduced and nothing unusual happened.

  8. Ultrasound beam characteristics of a symmetric nodal origami based array

    Science.gov (United States)

    Bilgunde, Prathamesh N.; Bond, Leonard J.

    2018-04-01

    Origami-the ancient art of paper folding-is being explored in acoustics for effective focusing of sound. In this short communication, we present a numerical investigation of beam characteristics for an origami based ultrasound array. A spatial re-configuration of array elements is performed based upon the symmetric nodal origami. The effect of fold angle on the ultrasound beam is evaluated using frequency domain and transient finite element analysis. It was found that increase in the fold angle reduces near field length by 58% and also doubles the beam intensity as compared to the linear array. Transient analysis also indicated 80% reduction in the -6dB beam width, which can improve the lateral resolution of phased array. Such a spatially re-configurable array could potentially be used in the future to reduce the cost of electronics in the phased array instrumentation.

  9. Space-angle approximations in the variational nodal method

    International Nuclear Information System (INIS)

    Lewis, E. E.; Palmiotti, G.; Taiwo, T.

    1999-01-01

    The variational nodal method is formulated such that the angular and spatial approximations maybe examined separately. Spherical harmonic, simplified spherical harmonic, and discrete ordinate approximations are coupled to the primal hybrid finite element treatment of the spatial variables. Within this framework, two classes of spatial trial functions are presented: (1) orthogonal polynomials for the treatment of homogeneous nodes and (2) bilinear finite subelement trial functions for the treatment of fuel assembly sized nodes in which fuel-pin cell cross sections are represented explicitly. Polynomial and subelement trial functions are applied to benchmark water-reactor problems containing MOX fuel using spherical harmonic and simplified spherical harmonic approximations. The resulting accuracy and computing costs are compared

  10. A nonlinear analytic function expansion nodal method for transient calculations

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Han Gyn; Park, Sang Yoon; Cho, Byung Oh; Zee, Sung Quun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-12-31

    The nonlinear analytic function expansion nodal (AFEN) method is applied to the solution of the time-dependent neutron diffusion equation. Since the AFEN method requires both the particular solution and the homogeneous solution to the transient fixed source problem, the derivation of the solution method is focused on finding the particular solution efficiently. To avoid complicated particular solutions, the source distribution is approximated by quadratic polynomials and the transient source is constructed such that the error due to the quadratic approximation is minimized, In addition, this paper presents a new two-node solution scheme that is derived by imposing the constraint of current continuity at the interface corner points. The method is verified through a series of application to the NEACRP PWR rod ejection benchmark problems. 6 refs., 2 figs., 1 tab. (Author)

  11. ANDREA: Advanced nodal diffusion code for reactor analysis

    International Nuclear Information System (INIS)

    Belac, J.; Josek, R.; Klecka, L.; Stary, V.; Vocka, R.

    2005-01-01

    A new macro code is being developed at NRI which will allow coupling of the advanced thermal-hydraulics model with neutronics calculations as well as efficient use in core loading pattern optimization process. This paper describes the current stage of the macro code development. The core simulator is based on the nodal expansion method, Helios lattice code is used for few group libraries preparation. Standard features such as pin wise power reconstruction and feedback iterations on critical control rod position, boron concentration and reactor power are implemented. A special attention is paid to the system and code modularity in order to enable flexible and easy implementation of new features in future. Precision of the methods used in the macro code has been verified on available benchmarks. Testing against Temelin PWR operational data is under way (Authors)

  12. Comparison of PANTHER nodal solutions in hexagonal-z geometry

    International Nuclear Information System (INIS)

    Knight, M.; Hutt, P.; Lewis, I.

    1995-01-01

    The reactor physics code PANTHER has been extended to hexagonal geometries. Steady-state, depletion, and transient calculations with feedback can all be performed. Two hexagonal nodal flux solutions have been developed. In the first method, transverse integration is performed exactly as in the rectangular case. The resulting transverse integrated equation has singular terms, which are simply ignored. The second approach applies a conformal mapping that transforms the hexagon onto a rectangle. Pin power reconstruction has also been developed with both methods. For a benchmark VVER-1000 reactor depletion problem, both methods give accurate results for standard depletion calculations. In the more extreme situation with all rods inserted, the simpler method breaks down. However, the accuracy of the conformal solution was found to be excellent in all cases studied

  13. Static benchmarking of the NESTLE advanced nodal code

    International Nuclear Information System (INIS)

    Mosteller, R.D.

    1997-01-01

    Results from the NESTLE advanced nodal code are presented for multidimensional numerical benchmarks representing four different types of reactors, and predictions from NESTLE are compared with measured data from pressurized water reactors (PWRs). The numerical benchmarks include cases representative of PWRs, boiling water reactors (BWRs), CANDU heavy water reactors (HWRs), and high-temperature gas-cooled reactors (HTGRs). The measured PWR data include critical soluble boron concentrations and isothermal temperature coefficients of reactivity. The results demonstrate that NESTLE correctly solves the multigroup diffusion equations for both Cartesian and hexagonal geometries, that it reliably calculates k eff and reactivity coefficients for PWRs, and that--subsequent to the incorporation of additional thermal-hydraulic models--it will be able to perform accurate calculations for the corresponding parameters in BWRs, HWRs, and HTGRs as well

  14. Contemporary Management of Recurrent Nodal Disease in Differentiated Thyroid Carcinoma

    Science.gov (United States)

    Na’ara, Shorook; Amit, Moran; Fridman, Eran; Gil, Ziv

    2016-01-01

    Differentiated thyroid carcinoma (DTC) comprises over 90% of thyroid tumors and includes papillary and follicular carcinomas. Patients with DTC have an excellent prognosis, with a 10-year survival rate of over 90%. However, the risk of recurrent tumor ranges between 5% and 30% within 10 years of the initial diagnosis. Cervical lymph node disease accounts for the majority of recurrences and in most cases is detected during follow-up by ultrasound or elevated levels of serum thyroglobulin. Recurrent disease is accompanied by increased morbidity. The mainstay of treatment of nodal recurrence is surgical management. We provide an overview of the literature addressing surgical management of recurrent or persistent lymph node disease in patients with DTC. PMID:26886954

  15. Error Estimation and Accuracy Improvements in Nodal Transport Methods

    International Nuclear Information System (INIS)

    Zamonsky, O.M.

    2000-01-01

    The accuracy of the solutions produced by the Discrete Ordinates neutron transport nodal methods is analyzed.The obtained new numerical methodologies increase the accuracy of the analyzed scheems and give a POSTERIORI error estimators. The accuracy improvement is obtained with new equations that make the numerical procedure free of truncation errors and proposing spatial reconstructions of the angular fluxes that are more accurate than those used until present. An a POSTERIORI error estimator is rigurously obtained for one dimensional systems that, in certain type of problems, allows to quantify the accuracy of the solutions. From comparisons with the one dimensional results, an a POSTERIORI error estimator is also obtained for multidimensional systems. LOCAL indicators, which quantify the spatial distribution of the errors, are obtained by the decomposition of the menctioned estimators. This makes the proposed methodology suitable to perform adaptive calculations. Some numerical examples are presented to validate the theoretical developements and to illustrate the ranges where the proposed approximations are valid

  16. Nodal wear model: corrosion in carbon blast furnace hearths

    Directory of Open Access Journals (Sweden)

    Verdeja, L. F.

    2003-06-01

    Full Text Available Criterions developed for the Nodal Wear Model (NWM were applied to estimate the shape of the corrosion profiles that a blast furnace hearth may acquire during its campaign. Taking into account design of the hearth, the boundary conditions, the characteristics of the refractory materials used and the operation conditions of the blast furnace, simulation of wear profiles with central well, mushroom and elephant foot shape were accomplished. The foundations of the NWM are constructed considering that the corrosion of the refractory is a function of the temperature present at each point (node of the liquid metal-refractory interface and the corresponding physical and chemical characteristics of the corrosive fluid.

    Se aplican los criterios del Modelo de Desgaste Nodal (MDN para la estimación de los perfiles de corrosión que podría ir adquiriendo el crisol de un homo alto durante su campaña. Atendiendo al propio diseño del crisol, a las condiciones límites de contorno, a las características del material refractario utilizado y a las condiciones de operación del horno, se consiguen simular perfiles de desgaste con "pozo central", con "forma de seta" ó de "pie de elefante". Los fundamentos del MDN se apoyan en la idea de considerar que la corrosión del refractario es función de la temperatura que el sistema pueda presentar en cada punto (nodo de la intercara refractario-fundido y de las correspondientes características físico-químicas del fluido corrosivo.

  17. Sexual selection targets cetacean pelvic bones

    Science.gov (United States)

    Dines, J. P.; Otárola-Castillo, E.; Ralph, P.; Alas, J.; Daley, T.; Smith, A. D.; Dean, M. D.

    2014-01-01

    Male genitalia evolve rapidly, probably as a result of sexual selection. Whether this pattern extends to the internal infrastructure that influences genital movements remains unknown. Cetaceans (whales and dolphins) offer a unique opportunity to test this hypothesis: since evolving from land-dwelling ancestors, they lost external hind limbs and evolved a highly reduced pelvis which seems to serve no other function except to anchor muscles that maneuver the penis. Here we create a novel morphometric pipeline to analyze the size and shape evolution of pelvic bones from 130 individuals (29 species) in the context of inferred mating system. We present two main findings: 1) males from species with relatively intense sexual selection (inferred by relative testes size) have evolved relatively large penises and pelvic bones compared to their body size, and 2) pelvic bone shape diverges more quickly in species pairs that have diverged in inferred mating system. Neither pattern was observed in the anterior-most pair of vertebral ribs, which served as a negative control. This study provides evidence that sexual selection can affect internal anatomy that controls male genitalia. These important functions may explain why cetacean pelvic bones have not been lost through evolutionary time. PMID:25186496

  18. Biomimetic implants for pelvic floor repair

    NARCIS (Netherlands)

    Vashaghian, Mahshid; Zaat, Sebastianus A. J.; Smit, Theodoor H.; Roovers, Jan-Paul

    2017-01-01

    Polypropylene implants are used for the reconstructive surgery of urogynaecological disorders like pelvic organ prolapse, but severe complications associated with their use have been reported. There is evidence that surface properties and a difference in mechanical stiffness between the implant and

  19. A Suspected Pelvic Aneurysmal Bone Cyst in Pregnancy

    Directory of Open Access Journals (Sweden)

    Rayan Elkattah

    2013-01-01

    Full Text Available Albeit rare, the majority of identified bone lesions in pregnancy spare the pelvis. Once encountered with a pelvic bone lesion in pregnancy, the obstetrician may face a challenging situation as it is difficult to determine and predict the effects that labor and parturition impart on the pelvic bones. Bone changes and pelvic bone fractures have been well documented during childbirth. The data regarding clinical outcomes and management of pregnancies complicated by pelvic ABCs is scant. Highly suspected to represent an aneurysmal bone cyst, the clinical evaluation of a pelvic lesion in the ilium of a pregnant individual is presented, and modes of delivery in such a scenario are discussed.

  20. Treatment planning with protons for pediatric retinoblastoma, medulloblastoma, and pelvic sarcoma: How do protons compare with other conformal techniques?

    International Nuclear Information System (INIS)

    Lee, Catherine T.; Bilton, Stephen D.; Famiglietti, Robin M.; Riley, Beverly A.; Mahajan, Anita; Chang, Eric L.; Maor, Moshe H.; Woo, Shiao Y.; Cox, James D.; Smith, Alfred R.

    2005-01-01

    Purpose: To calculate treatment plans and compare the dose distributions and dose-volume histograms (DVHs) for photon three-dimensional conformal radiation therapy (3D-CRT), electron therapy, intensity-modulated radiation therapy (IMRT), and standard (nonintensity modulated) proton therapy in three pediatric disease sites. Methods and Materials: The tumor volumes from 8 patients (3 retinoblastomas, 2 medulloblastomas, and 3 pelvic sarcomas) were studied retrospectively to compare DVHs from proton therapy with 3D-CRT, electron therapy, and IMRT. In retinoblastoma, several planning techniques were analyzed: A single electron appositional beam was compared with a single 3D-CRT lateral beam, a 3D-CRT anterior beam paired with a lateral beam, IMRT, and protons. In medulloblastoma, three posterior fossa irradiation techniques were analyzed: 3D-CRT, IMRT, and protons. Craniospinal irradiation (which consisted of composite plans of both the posterior fossa and craniospinal components) was also evaluated, primarily comparing spinal irradiation using 3D-CRT electrons, 3D-CRT photons, and protons. Lastly, in pelvic sarcoma, 3D-CRT, IMRT, and proton plans were assessed. Results: In retinoblastoma, protons resulted in the best target coverage combined with the most orbital bone sparing (10% was the mean orbital bone volume irradiated at ≥5 Gy for protons vs. 25% for 3D-CRT electrons, 69% for IMRT, 41% for a single 3D lateral beam, 51% for a 3D anterolateral beam with a lens block, and 65% for a 3D anterolateral beam without a lens block). A single appositional electron field was the next best technique followed by other planning approaches. In medulloblastoma, for posterior fossa and craniospinal irradiation, protons resulted in the least dose to the cochlea (for only posterior fossa irradiation at ≥20 Gy, 34% was the mean cochlear volume irradiated for protons, 87% for IMRT, 89% for 3D-CRT) and hypothalamus-pituitary axis (for only posterior fossa irradiation at ≥10 Gy

  1. Re-irradiation for abdominal tumor. Preliminary results

    International Nuclear Information System (INIS)

    Narisada, Hiroyuki; Imada, Hajime; Tomoda, Yoshinori

    2012-01-01

    The purpose of this study was to assess the efficacy of loco-regional radiotherapy for recurrent abdominal tumor treated with re-irradiation. Re-irradiated areas of 16 patients were eight of pelvic space, five of retroperitonium and three of liver or porta hepatica. Eligibility criteria of re-irradiation were success of initial irradiation, no other effective treatment except re-irradiation, constancy of bowel gas at hunger status and respiratory movement, visceral dosage reduction at re-irradiation. Total dose of initial, second course of radiation were 51.3±10.8 Gy, 50.6±14.2 Gy, respectively. Interval of initial and second course of radiation were 16.6±10.2 months. Local control after second course of radiation was four cases of complete response, five of partial response and seven of stable disease. Median survival periods were 55 months after initial treatment and 28 months after second course of radiation. In two cases of pelvic reirradiation, skin to pelvic space fistula was occurred. Re-irradiation for abdominal tumor may become useful salvage treatment. (author)

  2. Elective Nodal Irradiation and Patterns of Failure in Head and Neck Cancer After Primary Radiation Therapy

    DEFF Research Database (Denmark)

    Kjems, Julie; Gothelf, Anita B; Håkansson, Katrin

    2016-01-01

    on recurrence in the retropharyngeal region and level IB. METHODS AND MATERIALS: From 2005 to 2012, 942 patients with oropharyngeal, hypopharyngeal, laryngeal or oral cavity carcinomas were curatively treated with primary radiation therapy. The median follow-up period was 34 months, and 77% of the patients...... underwent intensity modulated radiation therapy. The retropharyngeal region was only routinely included in cases of involvement of the posterior pharynx wall and level IB only in cases of involvement of the oral cavity. In patients with regional recurrence, the anatomic site of the recurrence was assessed...... likely to develop recurrence in distant sites. CONCLUSIONS: Retropharyngeal or level IB recurrence after primary HNC radiation therapy is rare. Thus, inclusion of these regions in the elective treatment volumes should be limited to patients with involvement of the posterior pharyngeal wall or oral cavity....

  3. [Quality of life in women with pelvic floor dysfunction].

    Science.gov (United States)

    Segedi, Ljiljana Mladenović; Ilić, Katarina Parezanović; Curcić, Aleksandar; Visnjevac, Nemanja

    2011-11-01

    Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfaction in adult women with pelvic organ prolapse presenting to tertiary care clinic for surgical treatment. This prospective case-control study included 50 patients who presented to tertiary care gynecology clinic for surgical treatment and 50 controls with normal pelvic floor support and without urinary incontinence who presented tertiary care gynecology clinic for other reasons. Both, patients and controls, completed two quastionnaires recommended for the evaluation of symptoms (Pelvic floor distress inventory - short forms) and quality of life impact (Pelvic floor impact questionnaire - short form) of pelvic organ prolapse, and Body Image Scale. The patients scored significantly worse on the prolapse, urinary, colorectal scales and overall score of Pelvic floor distress inventory--20 than controls subjects (134.91 vs 78.08; p self-conscious (78% vs 42%; p body. There was a positive correlation between decreased quality of life and body image in women with pelvic dysfunction. Women with pelvic floor dysfunction have decreased quality of life and body image.

  4. Surgical reconstruction of pelvic floor descent: anatomic and functional aspects.

    Science.gov (United States)

    Wagenlehner, F M E; Bschleipfer, T; Liedl, B; Gunnemann, A; Petros, P; Weidner, W

    2010-01-01

    The human pelvic floor is a complex structure and pelvic floor dysfunction is seen frequently in females. This review focuses on the surgical reconstruction of the pelvic floor employing recent findings on functional anatomy. A selective literature research was performed by the authors. Pelvic floor activity is regulated by 3 main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor organs, bladder and rectum. A variety of symptoms can derive from pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, fecal incontinence, obstructive bowel disease syndrome and pelvic pain. These symptoms mainly derive, for different reasons, from laxity in the vagina or its supporting ligaments as a result of altered connective tissue. Pelvic floor reconstruction is nowadays driven by the concept that in case of pelvic floor symptoms, restoration of the anatomy will translate into restoration of the physiology and ultimately improve patients' symptoms. The surgical reconstruction of the anatomy is almost exclusively focused on the restoration of the lax pelvic floor ligaments. Exact preoperative identification of the anatomical lesions is necessary to allow for exact anatomical reconstruction with respect to the muscular forces of the pelvic floor. Copyright 2010 S. Karger AG, Basel.

  5. [Modern aspects of surgical treatment of locally advanced pelvic cancer].

    Science.gov (United States)

    Solovyov, I A; Vasilchenko, M V; Lychev, A B; Ambartsumyan, S V; Alekseev, V V

    2015-09-01

    The aim of investigation is to improve surgical treatment of patients with locally advanced pelvic cancer. The basis of investigation is 186 patients with locally advanced pelvic cancer. The average age of patients is 65.2 ± 5.2 years (from 43.7 to 88.4 years). Among them are 112 women and 74 men. In the period from 2007 to 2015 they were carried out combined (101 patients) and expanded (85 patients) surgical intervention in the department of naval surgery of the Military medical academy after S.M.Kirov. Pelvic evisceration was performed in 63 cases. Both patients were performed isolated vascular hyperthermic chemical pelvic perfusion. Indications for plastic surgery of peritoneum pelvic were: total infralitoral pelvic evisceration (9 patients), dorsal infralitoral pelvic evisceration (11 cases) and expanded abdominoperineal rectum extirpation (34 patients). Plastic surgery with autogenouse tissues was performed to 43 patients, with reticulate explants--to 11 patients. The rate of postoperative complications was 40.2%. The rate of postoperative lethality was 8%. Expanded and combined operations of pelvic at patients with locally advanced cancer without absolute contra-indications can be performed irrespective of age. Plastic surgery of peritoneum pelvic after total and dorsal infralitoral pelvic evisceration and expanded abdominoperineal rectum extirpation indicated in all cases. The easiest method is plastic surgery with greater omentum or peritoneum pelvic. Plastic surgery with reticulate explants is performed when autoplastic is impossible.

  6. Hormonal treatment for endometriosis associated pelvic pain

    Directory of Open Access Journals (Sweden)

    Wu Shun Felix Wong

    2011-01-01

    Full Text Available AbstractBackground: Endometriosis is a common gynecological problem associated with chronic pelvic pain. Objective: To evaluate the effectiveness of current hormonal treatments of endometriosis associated pain.Materials and Methods: Randomized Controlled studies identified from databases of Medline and Cochrane Systemic Review groups were pooled. 7 RCTs were recruited for evaluation in this review. Data from these studies were pooled and meta-analysis was performed in three comparison groups: 1 Progestogen versus GnRHa; 2 Implanon versus Progestogen (injection; 3 Combined oral contraceptive pills versus placebo and progestogen. Response to treatment was measured as a reduction in pain score. Pain improvement was defined as improvement ≥1 at the end of treatment. Results: There was no significant difference between treatment groups of progestogen and GnRHa (RR: 0.036; CI:-0.030-0.102 for relieving endometriosis associated pelvic pain. Long acting progestogen (Implanon and Mirena are not inferior to GnRHa and depot medroxy progesterone acetate (DMPA (RR: 0.006; CI:-0.142-0.162. Combined oral contraceptive pills demonstrated effective treatment o