WorldWideScience

Sample records for pelvic helical tomotherapy

  1. Helical tomotherapy as a new treatment technique for whole abdominal irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Rochet, N.; Sterzing, F.; Jensen, A.; Herfarth, K.; Schubert, K.; Debus, J.; Harms, W. [Heidelberg Univ. (Germany). Dept. of Radiation Oncology; Dinkel, J. [German Cancer Research Center (dkfz), Heidelberg (Germany). Dept. of Radiology; Eichbaum, M.; Schneeweiss, A.; Sohn, C. [Heidelberg Univ. (Germany). Dept. of Gynecology and Obstetrics

    2008-03-15

    Purpose: To describe a new intensity-modulated radiotherapy (IMRT) technique using helical tomotherapy for whole abdominal irradiation (WAI) in patients with advanced ovarian cancer. Material and Methods: A patient with radically operated ovarian cancer FIGO stage IIIc was treated in a prospective clinical trial with WAI to a total dose of 30 Gy in 1.5-Gy fractions as an additional therapy after adjuvant platinum-based chemotherapy. The planning target volume (PTV) included the entire peritoneal cavity. PTV was adapted according to breathing motion as detected in a four-dimensional respiratory-triggered computed tomography (4D-CT). Inverse treatment planning was done with the Hi-Art tomotherapy planning station. Organs at risk (OARs) were kidneys, liver, bone marrow, spinal cord, thoracic and lumbosacral vertebral bodies, and pelvic bones. Daily control of positioning accuracy was performed with megavoltage computed tomography (MV-CT). Results: Helical tomotherapy enabled a very homogeneous dose distribution with excellent sparing of OARs and coverage of the PTV (V90 of 93.1%, V95 of 86.9%, V105 of 1.9%, and V110 of 0.01%). Mean liver dose was 21.57 Gy and mean kidney doses were 9.75 Gy and 9.14 Gy, respectively. Treatment could be performed in 18.1 min daily and no severe side effects occurred. Conclusion: Helical tomotherapy is feasible and fast for WAI. Tomotherapy enabled excellent coverage of the PTV and effective sparing of liver, kidneys and bone marrow. (orig.)

  2. Helical tomotherapy as a new treatment technique for whole abdominal irradiation

    International Nuclear Information System (INIS)

    Rochet, N.; Sterzing, F.; Jensen, A.; Herfarth, K.; Schubert, K.; Debus, J.; Harms, W.; Dinkel, J.; Eichbaum, M.; Schneeweiss, A.; Sohn, C.

    2008-01-01

    Purpose: To describe a new intensity-modulated radiotherapy (IMRT) technique using helical tomotherapy for whole abdominal irradiation (WAI) in patients with advanced ovarian cancer. Material and Methods: A patient with radically operated ovarian cancer FIGO stage IIIc was treated in a prospective clinical trial with WAI to a total dose of 30 Gy in 1.5-Gy fractions as an additional therapy after adjuvant platinum-based chemotherapy. The planning target volume (PTV) included the entire peritoneal cavity. PTV was adapted according to breathing motion as detected in a four-dimensional respiratory-triggered computed tomography (4D-CT). Inverse treatment planning was done with the Hi-Art tomotherapy planning station. Organs at risk (OARs) were kidneys, liver, bone marrow, spinal cord, thoracic and lumbosacral vertebral bodies, and pelvic bones. Daily control of positioning accuracy was performed with megavoltage computed tomography (MV-CT). Results: Helical tomotherapy enabled a very homogeneous dose distribution with excellent sparing of OARs and coverage of the PTV (V90 of 93.1%, V95 of 86.9%, V105 of 1.9%, and V110 of 0.01%). Mean liver dose was 21.57 Gy and mean kidney doses were 9.75 Gy and 9.14 Gy, respectively. Treatment could be performed in 18.1 min daily and no severe side effects occurred. Conclusion: Helical tomotherapy is feasible and fast for WAI. Tomotherapy enabled excellent coverage of the PTV and effective sparing of liver, kidneys and bone marrow. (orig.)

  3. A Prospective Evaluation of Helical Tomotherapy

    International Nuclear Information System (INIS)

    Bauman, Glenn; Yartsev, Slav; Rodrigues, George; Lewis, Craig; Venkatesan, Varagur M.; Yu, Edward; Hammond, Alex; Perera, Francisco; Ash, Robert; Dar, A. Rashid; Lock, Michael; Baily, Laura; Coad, Terry C; Trenka, Kris C.; Warr, Barbara; Kron, Tomas; Battista, Jerry; Van Dyk, Jake

    2007-01-01

    Purpose: To report results from two clinical trials evaluating helical tomotherapy (HT). Methods and Materials: Patients were enrolled in one of two prospective trials of HT (one for palliative and one for radical treatment). Both an HT plan and a companion three-dimensional conformal radiotherapy (3D-CRT) plan were generated. Pretreatment megavoltage computed tomography was used for daily image guidance. Results: From September 2004 to January 2006, a total of 61 sites in 60 patients were treated. In all but one case, a clinically acceptable tomotherapy plan for treatment was generated. Helical tomotherapy plans were subjectively equivalent or superior to 3D-CRT in 95% of plans. Helical tomotherapy was deemed equivalent or superior in two thirds of dose-volume point comparisons. In cases of inferiority, differences were either clinically insignificant and/or reflected deliberate tradeoffs to optimize the HT plan. Overall imaging and treatment time (median) was 27 min (range, 16-91 min). According to a patient questionnaire, 78% of patients were satisfied to very satisfied with the treatment process. Conclusions: Helical tomotherapy demonstrated clear advantages over conventional 3D-CRT in this diverse patient group. The prospective trials were helpful in deploying this technology in a busy clinical setting

  4. Total scalp irradiation using helical tomotherapy

    International Nuclear Information System (INIS)

    Orton, Nigel; Jaradat, Hazim; Welsh, James; Tome, Wolfgang

    2005-01-01

    Homogeneous irradiation of the scalp poses technical and dosimetric challenges due to the extensive, superficial, curved treatment volume. Conventional treatments on a linear accelerator use multiple matched electron fields or a combination of electron and photon fields. Problems with these techniques include dose heterogeneity in the target due to varying source-to-skin distance (SSD) and angle of beam incidence, significant dose to the brain, and the potential for overdose or underdose at match lines between the fields. Linac-based intensity-modulated radiation therapy (IMRT) plans have similar problems. This work presents treatment plans for total scalp irradiation on a helical tomotherapy machine. Helical tomotherapy is well-suited for scalp irradiation because it has the ability to deliver beamlets that are tangential to the scalp at all points. Helical tomotherapy also avoids problems associated with field matching and use of more than one modality. Tomotherapy treatment plans were generated and are compared to plans for treatment of the same patient on a linac. The resulting tomotherapy plans show more homogeneous target dose and improved critical structure dose when compared to state-of-the-art linac techniques. Target equivalent uniform dose (EUD) for the best tomotherapy plan was slightly higher than for the linac plan, while the volume of brain tissue receiving over 30 Gy was reduced by two thirds. Furthermore, the tomotherapy plan can be more reliably delivered than linac treatments, because the patient is aligned prior to each treatment based on megavoltage computed tomography (MVCT)

  5. Whole pelvic helical tomotherapy for locally advanced cervical cancer: technical implementation of IMRT with helical tomothearapy

    International Nuclear Information System (INIS)

    Hsieh, Chen-Hsi; Shueng, Pei-Wei; Wei, Ming-Chow; Lee, Hsing-Yi; Hsiao, Sheng-Mou; Chen, Chien-An; Wang, Li-Ying; Hsieh, Yen-Ping; Tsai, Tung-Hu; Chen, Yu-Jen

    2009-01-01

    To review the experience and to evaluate the treatment plan of using helical tomotherapy (HT) for the treatment of cervical cancer. Between November 1st, 2006 and May 31, 2009, 10 cervical cancer patients histologically confirmed were enrolled. All of the patients received definitive concurrent chemoradiation (CCRT) with whole pelvic HT (WPHT) followed by brachytherapy. During WPHT, all patients were treated with cisplatin, 40 mg/m 2 intravenously weekly. Toxicity of treatment was scored according to the Common Terminology Criteria for Adverse Events v3.0 (CTCAE v3.0). The mean survival was 25 months (range, 3 to 27 months). The actuarial overall survival, disease-free survival, locoregional control and distant metastasis-free rates at 2 years were 67%, 77%, 90% and 88%, respectively. The average of uniformity index and conformal index was 1.06 and 1.19, respectively. One grade 3 of acute toxicity for diarrhea, thrombocytopenia and three grade 3 leucopenia were noted during CCRT. Only one grade 3 of subacute toxicity for thrombocytopenia was noted. There were no grade 3 or 4 subacute toxicities of anemia, leucopenia, genitourinary or gastrointestinal effects. Compared with conventional whole pelvic radiation therapy (WPRT), WPHT decreases the mean dose to rectum, bladder and intestines successfully. HT provides feasible clinical outcomes in locally advanced cervical cancer patients. Long-term follow-up and enroll more locally advanced cervical carcinoma patients by limiting bone marrow radiation dose with WPHT technique is warranted

  6. Helical Tomotherapy Quality Assurance

    International Nuclear Information System (INIS)

    Balog, John; Soisson, Emilie

    2008-01-01

    Helical tomotherapy uses a dynamic delivery in which the gantry, treatment couch, and multileaf collimator leaves are all in motion during treatment. This results in highly conformal radiotherapy, but the complexity of the delivery is partially hidden from the end-user because of the extensive integration and automation of the tomotherapy control systems. This presents a challenge to the medical physicist who is expected to be both a system user and an expert, capable of verifying relevant aspects of treatment delivery. A related issue is that a clinical tomotherapy planning system arrives at a customer's site already commissioned by the manufacturer, not by the clinical physicist. The clinical physicist and the manufacturer's representative verify the commissioning at the customer site before acceptance. Theoretically, treatment could begin immediately after acceptance. However, the clinical physicist is responsible for the safe and proper use of the machine. In addition, the therapists and radiation oncologists need to understand the important machine characteristics before treatment can proceed. Typically, treatment begins about 2 weeks after acceptance. This report presents an overview of the tomotherapy system. Helical tomotherapy has unique dosimetry characteristics, and some of those features are emphasized. The integrated treatment planning, delivery, and patient-plan quality assurance process is described. A quality assurance protocol is proposed, with an emphasis on what a clinical medical physicist could and should check. Additionally, aspects of a tomotherapy quality assurance program that could be checked automatically and remotely because of its inherent imaging system and integrated database are discussed

  7. Radiation characteristics of helical tomotherapy

    International Nuclear Information System (INIS)

    Jeraj, Robert; Mackie, Thomas R.; Balog, John; Olivera, Gustavo; Pearson, Dave; Kapatoes, Jeff; Ruchala, Ken; Reckwerdt, Paul

    2004-01-01

    Helical tomotherapy is a dedicated intensity modulated radiation therapy (IMRT) system with on-board imaging capability (MVCT) and therefore differs from conventional treatment units. Different design goals resulted in some distinctive radiation field characteristics. The most significant differences in the design are the lack of flattening filter, increased shielding of the collimators, treatment and imaging operation modes and narrow fan beam delivery. Radiation characteristics of the helical tomotherapy system, sensitivity studies of various incident electron beam parameters and radiation safety analyses are presented here. It was determined that the photon beam energy spectrum of helical tomotherapy is similar to that of more conventional radiation treatment units. The two operational modes of the system result in different nominal energies of the incident electron beam with approximately 6 MeV and 3.5 MeV in the treatment and imaging modes, respectively. The off-axis mean energy dependence is much lower than in conventional radiotherapy units with less than 5% variation across the field, which is the consequence of the absent flattening filter. For the same reason the transverse profile exhibits the characteristic conical shape resulting in a 2-fold increase of the beam intensity in the center. The radiation leakage outside the field was found to be negligible at less than 0.05% because of the increased shielding of the collimators. At this level the in-field scattering is a dominant source of the radiation outside the field and thus a narrow field treatment does not result in the increased leakage. The sensitivity studies showed increased sensitivity on the incident electron position because of the narrow fan beam delivery and high sensitivity on the incident electron energy, as common to other treatment systems. All in all, it was determined that helical tomotherapy is a system with some unique radiation characteristics, which have been to a large extent

  8. The helical tomotherapy thread effect

    International Nuclear Information System (INIS)

    Kissick, M.W.; Fenwick, J.; James, J.A.; Jeraj, R.; Kapatoes, J.M.; Keller, H.; Mackie, T.R.; Olivera, G.; Soisson, E.T.

    2005-01-01

    Inherent to helical tomotherapy is a dose variation pattern that manifests as a 'ripple' (peak-to-trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering or beam divergence, an analytical posing of the problem as a simple integral predicts minima near a pitch of 1/n where n is an integer. A convolution-superposition dose calculator (TomoTherapy, Inc.) included all the physics needed to explore the ripple magnitude versus pitch and beam width. The results of the dose calculator and some benchmark measurements demonstrate that the ripple has sharp minima near p=0.86(1/n). The 0.86 factor is empirical and caused by a beam junctioning of the off-axis dose profiles which differ from the axial profiles as well as a long scatter tail of the profiles at depth. For very strong intensity modulation, the 0.86 factor may vary. The authors propose choosing particular minima pitches or using a second delivery that starts 180 deg off-phase from the first to reduce these ripples: 'Double threading'. For current typical pitches and beam widths, however, this effect is small and not clinically important for most situations. Certain extremely large field or high pitch cases, however, may benefit from mitigation of this effect

  9. Conformal avoidance helical tomotherapy for dogs with nasopharyngeal tumors

    International Nuclear Information System (INIS)

    Welsh, J.S.; Turek, M.; Mackie, T.R.; Miller, P.; Mehta, M.P.; Forrest, L.J.

    2003-01-01

    Helical tomotherapy provides a unique means of delivering intensity-modulated radiation therapy (IMRT) using a novel treatment unit, which merges features of a linear accelerator with a helical CT scanner. Thanks to the CT imaging capacity, targeted regions can be visualized prior to, during, or immediately after each treatment. Such image-guidance through megavoltage CT will allow the realization and refinement of the concept of adaptive radiotherapy - the reconstruction of the actually delivered daily dose (as opposed to planned dose) accompanied by prescription adjustments when appropriate. In addition to this unique feature, helical tomotherapy promises further improvements in the specific avoidance of critical normal structures, i.e. conformal avoidance, the counterpart of conformal therapy. The first definitive treatment protocol using helical tomotherapy is presently underway for dogs with nasopharyngeal tumors. In general, such tumors can be treated with conventional external beam radiation therapy but at the cost of severe ocular toxicity due to the anatomy of the canine head. These are readily measurable toxicities and are almost universal in incidence; therefore, the canine nasopharyngeal tumor presents an ideal model to assess the ability to conformally avoid critical structures. It is hoped that conformal avoidance helical tomotherapy will improve tumor control via dose-escalation while reducing ocular toxicity in these veterinary patients. A total of 10 fractions are scheduled for these patients; the first 3 dogs have all received at least 7 fractions delivered via helical tomotherapy. Although preliminary, the first 3 dogs treated have not shown any evidence of ocular toxicity in this ongoing study

  10. Standard and Nonstandard Craniospinal Radiotherapy Using Helical TomoTherapy

    International Nuclear Information System (INIS)

    Parker, William; Brodeur, Marylene; Roberge, David; Freeman, Carolyn

    2010-01-01

    Purpose: To show the advantages of planning and delivering craniospinal radiotherapy with helical TomoTherapy (TomoTherapy Inc., Madison, WI) by presenting 4 cases treated at our institution. Methods and Materials: We first present a standard case of craniospinal irradiation in a patient with recurrent myxopapillary ependymoma (MPE) and follow this with 2 cases requiring differential dosing to multiple target volumes. One of these, a patient with recurrent medulloblastoma, required a lower dose to be delivered to the posterior fossa because the patient had been previously irradiated to the full dose, and the other required concurrent boosts to leptomeningeal metastases as part of his treatment for newly diagnosed MPE. The final case presented is a patient with pronounced scoliosis who required spinal irradiation for recurrent MPE. Results: The four cases presented were planned and treated successfully with Helical Tomotherapy. Conclusions: Helical TomoTherapy delivers continuous arc-based intensity-modulated radiotherapy that gives high conformality and excellent dose homogeneity for the target volumes. Increased healthy tissue sparing is achieved at higher doses albeit at the expense of larger volumes of tissue receiving lower doses. Helical TomoTherapy allows for differential dosing of multiple targets, resulting in very elegant dose distributions. Daily megavoltage computed tomography imaging allows for precision of patient positioning, permitting a reduction in planning margins and increased healthy tissue sparing in comparison with standard techniques.

  11. QA for helical tomotherapy: Report of the AAPM Task Group 148

    Energy Technology Data Exchange (ETDEWEB)

    Langen, Katja M.; Papanikolaou, Niko; Balog, John; Crilly, Richard; Followill, David; Goddu, S. Murty; Grant, Walter III; Olivera, Gustavo; Ramsey, Chester R.; Shi Chengyu [Department of Radiation Oncology, M. D. Anderson Cancer Center Orlando, Orlando, Florida 32806 (United States); Department of Radiation Oncology, Cancer Therapy and Research Center, University of Texas Health Science Center at San Antonio, San Antonio, Texas 78229 (United States); Mohawk Valley Medical Physics, Rome, New York 13440 (United States); Department of Radiation Medicine, Oregon Health and Science University, Portland, Oregon 97239 (United States); Section of Outreach Physics, University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030 (United States); Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Department of Radiology/Section of Radiation Oncology, Baylor College of Medicine, Methodist Hospital, Houston, Texas 77030 (United States); TomoTherapy, Inc., Madison, Wisconsin 53717 and Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States); Thompson Cancer Survival Center, Knoxville, Tennessee 37916 (United States); Department of Radiation Oncology, Cancer Therapy and Research Center, University of Texas Health Science Center at San Antonio, San Antonio, Texas 78229 (United States)

    2010-09-15

    Helical tomotherapy is a relatively new modality with integrated treatment planning and delivery hardware for radiation therapy treatments. In view of the uniqueness of the hardware design of the helical tomotherapy unit and its implications in routine quality assurance, the Therapy Physics Committee of the American Association of Physicists in Medicine commissioned Task Group 148 to review this modality and make recommendations for quality assurance related methodologies. The specific objectives of this Task Group are: (a) To discuss quality assurance techniques, frequencies, and tolerances and (b) discuss dosimetric verification techniques applicable to this unit. This report summarizes the findings of the Task Group and aims to provide the practicing clinical medical physicist with the insight into the technology that is necessary to establish an independent and comprehensive quality assurance program for a helical tomotherapy unit. The emphasis of the report is to describe the rationale for the proposed QA program and to provide example tests that can be performed, drawing from the collective experience of the task group members and the published literature. It is expected that as technology continues to evolve, so will the test procedures that may be used in the future to perform comprehensive quality assurance for helical tomotherapy units.

  12. Adaptive radiotherapy using helical tomotherapy system

    International Nuclear Information System (INIS)

    Jeswani, Sam; Ruchala, Kenneth; Olivera, Gustavo; Mackie, T.R.

    2008-01-01

    As commonly known in the field, adaptive radiation therapy (ART) is the use of feedback to modify a radiotherapy treatment. There are numerous ways in which this feedback can be received and used, and this presentation will discuss some of the implementations of ART being investigated with a helical TomoTherapy system

  13. Motion-induced dose artifacts in helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bryan; Chen, Jeff; Battista, Jerry [London Regional Cancer Program, London Health Sciences Centre, London, ON (Canada); Kron, Tomas [Peter MacCallum Cancer Center, Melbourne (Australia)], E-mail: bryan.kim@lhsc.on.ca

    2009-10-07

    Tumor motion is a particular concern for a complex treatment modality such as helical tomotherapy, where couch position, gantry rotation and MLC leaf opening all change with time. In the present study, we have investigated the impact of tumor motion for helical tomotherapy, which could result in three distinct motion-induced dose artifacts, namely (1) dose rounding, (2) dose rippling and (3) IMRT leaf opening asynchronization effect. Dose rounding and dose rippling effects have been previously described, while the IMRT leaf opening asynchronization effect is a newly discovered motion-induced dose artifact. Dose rounding is the penumbral widening of a delivered dose distribution near the edges of a target volume along the direction of tumor motion. Dose rippling is a series of periodic dose peaks and valleys observed within the target region along the direction of couch motion, due to an asynchronous interplay between the couch motion and the longitudinal component of tumor motion. The IMRT leaf opening asynchronization effect is caused by an asynchronous interplay between the temporal patterns of leaf openings and tumor motion. The characteristics of each dose artifact were investigated individually as functions of target motion amplitude and period for both non-IMRT and IMRT helical tomotherapy cases, through computer simulation modeling and experimental verification. The longitudinal dose profiles generated by the simulation program agreed with the experimental data within {+-}0.5% and {+-}1.5% inside the PTV region for the non-IMRT and IMRT cases, respectively. The dose rounding effect produced a penumbral increase up to 20.5 mm for peak-to-peak target motion amplitudes ranging from 1.0 cm to 5.0 cm. Maximum dose rippling magnitude of 25% was calculated, when the target motion period approached an unusually high value of 10 s. The IMRT leaf opening asynchronization effect produced dose differences ranging from -29% to 7% inside the PTV region. This information

  14. Risk of radiation-induced pneumonitis after helical and static-port tomotherapy in lung cancer patients and experimental rats

    International Nuclear Information System (INIS)

    Zhang, Xianglan; Shin, You Keun; Zheng, Zhenlong; Zhu, Lianhua; Lee, Ik Jae

    2015-01-01

    Radiotherapy (RT) is one of the major non-operative treatment modalities for treating lung cancer. Tomotherapy is an advanced type of intensity-modulated radiotherapy (IMRT) in which radiation may be delivered in a helical fashion. However, unexpected pneumonitis may occur in patients treated with tomotherapy, especially in combination with chemotherapy, as a result of extensive low-dose radiation of large lung volumes. The aim of our study was to investigate the risk of radiation-induced pneumonitis after helical-mode and static-mode tomotherapy in patients with lung cancer and in an animal model. A total of 63 patients with primary lung cancer who were treated with static or helical tomotherapy with or without concurrent chemoradiotherapy (CCRT) were analyzed. Additionally, rats with radiation-induced pulmonary toxicity, which was induced by the application of helical or static tomography with or without CCRT, were evaluated. Helical-mode tomotherapy resulted in a significantly higher rate of late radiation pneumonitis in lung cancer patients than static-mode tomotherapy when evaluated by the Radiation Therapy Oncology Group (RTOG) and National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) scoring system. In the animal model, helical tomotherapy alone induced significantly higher expression of interleukin (IL)-1α, IL-1β, IL-6, and transforming growth factor (TGF)-β in lung specimens, especially on the untreated side, compared to static tomotherapy alone. Additionally, rats treated with helical tomotherapy and CCRT demonstrated significantly higher expression of inflammatory cytokines compared to those treated with static tomotherapy and CCRT. Rat models treated with tomotherapy with or without CCRT could present similar patterns of pulmonary toxicity to those shown in lung cancer patients. The models can be used in further investigations of radiation induced pulmonary toxicity

  15. Helical Tomotherapy-Based STAT RT: Dosimetric Evaluation for Clinical Implementation of a Rapid Radiation Palliation Program

    International Nuclear Information System (INIS)

    McIntosh, Alyson; Dunlap, Neal; Sheng, Ke; Geezey, Constance; Turner, Benton; Blackhall, Leslie; Weiss, Geoffrey; Lappinen, Eric; Larner, James M.; Read, Paul W.

    2010-01-01

    Helical tomotherapy-based STAT radiation therapy (RT) uses an efficient software algorithm for rapid intensity-modulated treatment planning, enabling conformal radiation treatment plans to be generated on megavoltage computed tomography (MVCT) scans for CT simulation, treatment planning, and treatment delivery in one session. We compared helical tomotherapy-based STAT RT dosimetry with standard linac-based 3D conformal plans and standard helical tomotherapy-based intensity-modulated radiation therapy (IMRT) dosimetry for palliative treatments of whole brain, a central obstructive lung mass, multilevel spine disease, and a hip metastasis. Specifically, we compared the conformality, homogeneity, and dose with regional organs at risk (OARs) for each plan as an initial step in the clinical implementation of a STAT RT rapid radiation palliation program. Hypothetical planning target volumes (PTVs) were contoured on an anthropomorphic phantom in the lung, spine, brain, and hip. Treatment plans were created using three planning techniques: 3D conformal on Pinnacle 3 , helical tomotherapy, and helical tomotherapy-based STAT RT. Plan homogeneity, conformality, and dose to OARs were analyzed and compared. STAT RT and tomotherapy improved conformality indices for spine and lung plans (CI spine = 1.21, 1.17; CI lung = 1.20, 1.07, respectively) in comparison with standard palliative anteroposterior/posteroanterior (AP/PA) treatment plans (CI spine = 7.01, CI lung = 7.30), with better sparing of heart, esophagus, and spinal cord. For palliative whole-brain radiotherapy, STAT RT and tomotherapy reduced maximum and mean doses to the orbits and lens (maximum/mean lens dose: STAT RT = 2.94/2.65 Gy, tomotherapy = 3.13/2.80 Gy, Lateral opposed fields = 7.02/3.65 Gy), with an increased dose to the scalp (mean scalp dose: STAT RT = 16.19 Gy, tomotherapy = 15.61 Gy, lateral opposed fields = 14.01 Gy). For bony metastatic hip lesions, conformality with both tomotherapy techniques (CI = 1

  16. [Technique of complex mammary irradiation: Mono-isocentric 3D conformational radiotherapy and helical tomotherapy].

    Science.gov (United States)

    Vandendorpe, B; Guilbert, P; Champagne, C; Antoni, T; Nguyen, T D; Gaillot-Petit, N; Servagi Vernat, S

    2017-12-01

    To evaluate the dosimetric contribution of helical tomotherapy for breast cancers compared with conformal radiotherapy in mono-isocentric technique. For 23 patients, the dosimetric results in mono-isocentric 3D conformational radiotherapy did not satisfy the constraints either of target volumes nor organs at risk. A prospective dosimetric comparison between mono-isocentric 3D conformational radiotherapy and helical tomotherapy was therefore carried out. The use of helical tomotherapy showed a benefit in these 23 patients, with either an improvement in the conformity index or homogeneity, but with an increase in low doses. Of the 23 patients, two had pectus excavatum, five had past thoracic irradiation and two required bilateral irradiation. The other 14 patients had a combination of morphology and/or indication of lymph node irradiation. For these patients, helical tomotherapy was therefore preferred to mono-isocentric 3D conformational radiotherapy. Tomotherapy appears to provide better homogeneity and tumour coverage. This technique of irradiation may be justified in the case of morphological situations such as pectus exavatum and in complex clinical situations. In other cases, conformal radiotherapy in mono-isocentric technique remains to be favoured. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  17. Dosimetric verification of helical tomotherapy for total scalp irradiation

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Soisson, Emilie; Metcalfe, Peter; Rosenfeld, Anatoly B.; Tome, Wolfgang A.

    2008-01-01

    Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for a helical tomotherapy total scalp irradiation have been measured on an anthropomorphic phantom using radiochromic and radiographic film as well as a new skin dosimeter, the MOSkin. The superficial dose was found to be accurately calculated by the TomoTherapy planning system. This is in contrast to recent reports, probably due to a combination of the smaller dose grid resolution used in planning and this particular treatment primarily consisting of beamlets tangential to the scalp. The superficial dose was found to increase from 33.6 to 41.2 Gy and 36.0 to 42.0 Gy over the first 2 mm depth in the phantom in selected regions of the PTV, measured with radiochromic film. The prescription dose was 40 Gy. The superficial dose was at the prescription dose or higher in some regions due to the bolus effect of the thermoplastic head mask and the head rest used to aid treatment setup. It is suggested that to achieve the prescription dose at the surface (≤2 mm depth) bolus or a custom thermoplastic helmet is used.

  18. Feasibility study of helical tomotherapy for total body or total marrow irradiation

    International Nuclear Information System (INIS)

    Hui, Susanta K.; Kapatoes, Jeff; Fowler, Jack; Henderson, Douglas; Olivera, Gustavo; Manon, Rafael R.; Gerbi, Bruce; Mackie, T. R.; Welsh, James S.

    2005-01-01

    Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30 min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction. (C) We placed thermoluminescent detectors (TLDs) inside a Rando phantom to measure the dose at seven anatomical sites, including the lungs. A simulated TBI treatment showed homogeneous dose coverage (±10%) to the whole body. Doses to the sensitive organs were reduced by 35%-70% of the target dose. TLD measurements on Rando showed an accurate dose delivery (±7%) to the target and critical organs. In the TMI study, the dose was delivered conformally to the bone marrow only. The TBI and TMI treatment delivery time was reduced (by 50%) by increasing the field width from 2.5 to 5.0 cm in the inferior-superior direction. A limited MVCT reduced the target localization time 60% compared to whole body MVCT. MVCT image-guided helical tomotherapy offers a novel method to deliver a precise, homogeneous radiation dose to the whole body target while reducing the dose significantly to all critical organs. A judicious selection of pitch, modulation factor, and field size is required to produce a homogeneous dose distribution along with an acceptable treatment time. In

  19. A delivery transfer function (DTF) analysis for helical tomotherapy

    International Nuclear Information System (INIS)

    Kissick, Michael W; Mackie, Thomas Rockwell; Jeraj, Robert

    2007-01-01

    The previous theoretical work of a delivery transfer function (DTF) in radiotherapy is expanded to include the unique intensity modulation method of helical tomotherapy. In addition to the collimation of each beamlet, and the Gaussian scatter convolution spreading of the dose that other radiotherapy units have, helical tomotherapy uses 51 small arcs of varying lengths to adjust the intensity. The blurring from these arcs is not taken into account during treatment planning. A theoretical DTF is constructed, and a calculation is performed which includes this unique source motion in relation to the other DTF components. Various typical delivery parameters are used to generate resolution maps for a constant intensity projection. Near the isocenter, the transverse (to a given beam direction) blurring is small but at larger radii (>6 cm), the source blurring dominates over leaf size. For most clinical situations, this inherent source motion blurring is expected to be negligible

  20. Prospective Phase I-II Trial of Helical Tomotherapy With or Without Chemotherapy for Postoperative Cervical Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Julie K., E-mail: jschwarz@radonc.wustl.edu [Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States); Department of Cell Biology and Physiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States); Alvin J. Siteman Cancer Center, Washington University School of Medicine, St. Louis, MO (United States); Wahab, Sasa [Cobb Center for Radiation Oncology Center, Austell, GA (United States); Grigsby, Perry W. [Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States); Alvin J. Siteman Cancer Center, Washington University School of Medicine, St. Louis, MO (United States); Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States); Department of Obstetrics and Gynecology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States)

    2011-12-01

    Purpose: To investigate, in a prospective trial, the acute and chronic toxicity of patients with cervical cancer treated with surgery and postoperative intensity-modulated radiotherapy (RT) delivered using helical tomotherapy, with or without the administration of concurrent chemotherapy. Patients and Methods: A total of 24 evaluable patients entered the study between March 2006 and August 2009. The indications for postoperative RT were tumor size, lymphovascular space invasion, and the depth of cervical stromal invasion in 15 patients; 9 patients underwent postoperative RT because of surgically positive lymph nodes. All patients underwent pelvic RT delivered with helical tomotherapy and intracavitary high-dose-rate brachytherapy. Treatment consisted of concurrent weekly platinum in 17, sequential carboplatin/Taxol in 1, and RT alone in 6. The patients were monitored for acute and chronic toxicity using the Common Toxicity Criteria, version 3.0. Results: The median follow-up was 24 months (range, 4-49). At the last follow-up visit, 23 patients were alive and disease free. Of the 24 patients, 12 (50%) experienced acute Grade 3 gastrointestinal toxicity (anorexia in 5, diarrhea in 4, and nausea in 3). One patient developed acute Grade 4 genitourinary toxicity (vesicovaginal fistula). For patients treated with concurrent chemotherapy, the incidence of acute Grade 3 and 4 hematologic toxicity was 71% and 24%, respectively. For patients treated without concurrent chemotherapy, the incidence of acute Grade 3 and 4 hematologic toxicity was 29% and 14%, respectively. Two long-term toxicities occurred (vesicovaginal fistula at 25 months and small bowel obstruction at 30 months). The overall and progression-free survival rate at 3 years for all patients was 100% and 89%, respectively. Conclusion: The results of our study have shown that postoperative external RT for cervical cancer delivered with helical tomotherapy and high-dose-rate brachytherapy and with or without

  1. Prospective Phase I-II Trial of Helical Tomotherapy With or Without Chemotherapy for Postoperative Cervical Cancer Patients

    International Nuclear Information System (INIS)

    Schwarz, Julie K.; Wahab, Sasa; Grigsby, Perry W.

    2011-01-01

    Purpose: To investigate, in a prospective trial, the acute and chronic toxicity of patients with cervical cancer treated with surgery and postoperative intensity-modulated radiotherapy (RT) delivered using helical tomotherapy, with or without the administration of concurrent chemotherapy. Patients and Methods: A total of 24 evaluable patients entered the study between March 2006 and August 2009. The indications for postoperative RT were tumor size, lymphovascular space invasion, and the depth of cervical stromal invasion in 15 patients; 9 patients underwent postoperative RT because of surgically positive lymph nodes. All patients underwent pelvic RT delivered with helical tomotherapy and intracavitary high-dose-rate brachytherapy. Treatment consisted of concurrent weekly platinum in 17, sequential carboplatin/Taxol in 1, and RT alone in 6. The patients were monitored for acute and chronic toxicity using the Common Toxicity Criteria, version 3.0. Results: The median follow-up was 24 months (range, 4–49). At the last follow-up visit, 23 patients were alive and disease free. Of the 24 patients, 12 (50%) experienced acute Grade 3 gastrointestinal toxicity (anorexia in 5, diarrhea in 4, and nausea in 3). One patient developed acute Grade 4 genitourinary toxicity (vesicovaginal fistula). For patients treated with concurrent chemotherapy, the incidence of acute Grade 3 and 4 hematologic toxicity was 71% and 24%, respectively. For patients treated without concurrent chemotherapy, the incidence of acute Grade 3 and 4 hematologic toxicity was 29% and 14%, respectively. Two long-term toxicities occurred (vesicovaginal fistula at 25 months and small bowel obstruction at 30 months). The overall and progression-free survival rate at 3 years for all patients was 100% and 89%, respectively. Conclusion: The results of our study have shown that postoperative external RT for cervical cancer delivered with helical tomotherapy and high-dose-rate brachytherapy and with or without

  2. Quality assurance of a helical tomotherapy machine

    International Nuclear Information System (INIS)

    Fenwick, J D; Tome, W A; Jaradat, H A; Hui, S K; James, J A; Balog, J P; DeSouza, C N; Lucas, D B; Olivera, G H; Mackie, T R; Paliwal, B R

    2004-01-01

    Helical tomotherapy has been developed at the University of Wisconsin, and 'Hi-Art II' clinical machines are now commercially manufactured. At the core of each machine lies a ring-gantry-mounted short linear accelerator which generates x-rays that are collimated into a fan beam of intensity-modulated radiation by a binary multileaf, the modulation being variable with gantry angle. Patients are treated lying on a couch which is translated continuously through the bore of the machine as the gantry rotates. Highly conformal dose-distributions can be delivered using this technique, which is the therapy equivalent of spiral computed tomography. The approach requires synchrony of gantry rotation, couch translation, accelerator pulsing and the opening and closing of the leaves of the binary multileaf collimator used to modulate the radiation beam. In the course of clinically implementing helical tomotherapy, we have developed a quality assurance (QA) system for our machine. The system is analogous to that recommended for conventional clinical linear accelerator QA by AAPM Task Group 40 but contains some novel components, reflecting differences between the Hi-Art devices and conventional clinical accelerators. Here the design and dosimetric characteristics of Hi-Art machines are summarized and the QA system is set out along with experimental details of its implementation. Connections between this machine-based QA work, pre-treatment patient-specific delivery QA and fraction-by-fraction dose verification are discussed

  3. Helical tomotherapy. Experiences of the first 150 patients in Heidelberg

    Energy Technology Data Exchange (ETDEWEB)

    Sterzing, F.; Schubert, K.; Sroka-Perez, G.; Kalz, J.; Debus, J.; Herfarth, K. [Dept. of Radiation Oncology, Univ. of Heidelberg (Germany)

    2008-01-15

    Background and purpose: helical tomotherapy was introduced into clinical routine at the Department of Radiation Oncology, University Hospital of Heidelberg, Germany, in July 2006. This report is intended to describe the experience with the first 150 patients treated with helical tomotherapy. Patient selection, time effort, handling of daily image guidance with megavoltage (MV) CT, and quality of radiation plans shall be assessed. Patients and methods: between July 2006 and May 2007, 150 patients were treated with helical tomotherapy in the University Hospital of Heidelberg. Mean age was 60 years with a minimum of 30 years and a maximum of 85 years. 79 of these patients received radiotherapy as a part of multimodal treatment pre- or postoperatively, 17 patients received treatment as a combined radiochemotherapy. 76% were treated with curative intent. Radiotherapy sites were central nervous system (n = 7), head and neck (n = 28), thoracic (n = 37), abdominal (n = 58) and skeletal system (n = 20). Most common tumor entities were prostate cancer (n = 28), breast cancer (n = 17), gastrointestinal tumors (n = 19), pharyngeal carcinoma (n = 14), lymphoma (n = 13), metastatic disease (bone n = 14, liver n = 6, lung n = 4, lymph node n = 2), sarcoma (n = 8), malignant pleural mesothelioma (n = 5), ovarian cancer treated with whole abdominal irradiation (n = 4), lung cancer (n = 3), skin malignancies (n = 3), chordoma (n = 2), meningioma (n = 2), one ependymoma and one medulloblastoma treated with craniospinal axis irradiation (n = 2), and others (n = 4). Nine patients were treated with single-fraction radiosurgery, nine with image-guided spinal reirradiation, and twelve patients were treated at multiple targets simultaneously. A pretreatment MV-CT scan was performed in 98.2% of the 3,026 fractions applied. After matching with the kilovoltage planning CT, corrections for translations and rotation around longitudinal axis (roll) were done. Results: mean time on table was 24

  4. Asymmetric fan beams (AFB) for improvement of the craniocaudal dose distribution in helical tomotherapy delivery

    International Nuclear Information System (INIS)

    Gladwish, Adam; Kron, Tomas; McNiven, Andrea; Bauman, Glenn; Van Dyk, Jake

    2004-01-01

    Helical tomotherapy (HT) is a novel radiotherapy technique that utilizes intensity modulated fan beams that deliver highly conformal dose distributions in a helical beam trajectory. The most significant limitation in dose delivery with a constant fan beam thickness (FBT) is the penumbra width of the dose distribution in the craniocaudal direction, which is equivalent to the FBT. We propose to employ a half-blocked fan beam at start and stop location to reduce the penumbra width by half. By opening the jaw slowly during the helical delivery until the desired FBT is achieved it is possible to create a sharper edge in the superior and inferior direction from the target. The technique was studied using a tomotherapy beam model implemented on a commercial treatment planning system (Theraplan Plus V3.0). It was demonstrated that the dose distribution delivered using a 25 mm fan beam can be improved significantly, to reduce the dose to normal structures located superiorly and inferiorly of the target. Dosimetry for this technique is straightforward down to a FBT of 15 mm and implementation should be simple as no changes in couch movement are required compared to a standard HT delivery. We conclude that the use of asymmetric collimated fan beams for the start and stop of the helical tomotherapeutic dose delivery has the potential of significantly improving the dose distribution in helical tomotherapy

  5. Gating-by-rotation: a solution to the problem of intratreatment motion in helical tomotherapy

    International Nuclear Information System (INIS)

    Kapatoes, J.M.; Olivera, G.H.; Schloesser, E.A.; Pearson, D.W.; Balog, J.P.; Ruchala, K.J.; Schmidt, R.; Reckwerdt, P.J.; Mehta, M.P.; Mackie, T.R.

    2001-01-01

    Purpose: To assess the feasibility of addressing intratreatment motion issues in helical tomotherapy by gating the treatments by rotation. Intratreatment motion is a problem common to all IMRT techniques. Traditional methods of gating in conformal radiotherapy and some forms of IMRT are not applicable to helical tomotherapy due to the continuous rotation of the gantry. An alternative method is presented. Materials and Methods: Rotation-gating in helical tomotherapy is the process in which one rotation of treatment is immediately followed by a rotation of non-treatment. This on-off strategy is repeated for the full treatment volume. During the treatment rotations, the patient is required to hold their breath while the intensity-modulated fan beam deposits dose. For the non-treatment rotations, the patient is allowed to breathe freely as all leaves of the MLC will be closed, the accelerator disabled, or both. The couch indexes normally for treatment rotations and holds the patient stationary during non-treatment rotations. An investigation was conducted to assess the feasibility of rotation-gating. Film was placed between two hemispheres of a water phantom and a continuous helical delivery was carried out with all leaves opened. The film was replaced and another treatment was performed employing rotation-gating. The two films were compared to assess the process. The films were irradiated to dose levels within the linear region of the film response curve (maximum film dose ∼35 cGy). Films were also acquired with all leaves closed to quantify leakage dose through the collimation systems. Results: Central profiles for the inferior-superior direction (parallel to the direction of translation) for both films are displayed in Figure 1. The profiles agree very well, illustrating that a rotation-gated treatment closely mimics a continuous helical delivery. The only significant discrepancy lay in the tails of the profiles: a higher film dose is seen for the rotation

  6. Image-guided total marrow and total lymphatic irradiation using helical tomotherapy

    International Nuclear Information System (INIS)

    Schultheiss, Timothy E.; Wong, Jeffrey; Liu, An; Olivera, Gustavo; Somlo, George

    2007-01-01

    Purpose: To develop a treatment technique to spare normal tissue and allow dose escalation in total body irradiation (TBI). We have developed intensity-modulated radiotherapy techniques for the total marrow irradiation (TMI), total lymphatic irradiation, or total bone marrow plus lymphatic irradiation using helical tomotherapy. Methods and Materials: For TBI, we typically use 12 Gy in 10 fractions delivered at an extended source-to-surface distance (SSD). Using helical tomotherapy, it is possible to deliver equally effective doses to the bone marrow and lymphatics while sparing normal organs to a significant degree. In the TMI patients, whole body skeletal bone, including the ribs and sternum, comprise the treatment target. In the total lymphatic irradiation, the target is expanded to include the spleen and major lymph node areas. Sanctuary sites for disease (brain and testes) are included when clinically indicated. Spared organs include the lungs, esophagus, parotid glands, eyes, oral cavity, liver, kidneys, stomach, small and large intestine, bladder, and ovaries. Results: With TBI, all normal organs received the TBI dose; with TMI, total lymphatic irradiation, and total bone marrow plus lymphatic irradiation, the visceral organs are spared. For the first 6 patients treated with TMI, the median dose to organs at risk averaged 51% lower than would be achieved with TBI. By putting greater weight on the avoidance of specific organs, greater sparing was possible. Conclusion: Sparing of normal tissues and dose escalation is possible using helical tomotherapy. Late effects such as radiation pneumonitis, veno-occlusive disease, cataracts, neurocognitive effects, and the development of second tumors should be diminished in severity and frequency according to the dose reduction realized for the organs at risk

  7. Treatment Planning for Pulsed Reduced Dose-Rate Radiotherapy in Helical Tomotherapy

    International Nuclear Information System (INIS)

    Rong Yi; Paliwal, Bhudatt; Howard, Steven P.; Welsh, James

    2011-01-01

    Purpose: Pulsed reduced dose-rate radiotherapy (PRDR) is a valuable method of reirradiation because of its potential to reduce late normal tissue toxicity while still yielding significant tumoricidal effect. A typical method using a conventional linear accelerator (linac) is to deliver a series of 20-cGy pulses separated by 3-min intervals to give an effective dose-rate of just under 7 cGy/min. Such a strategy is fraught with difficulties when attempted on a helical tomotherapy unit. We investigated various means to overcome this limitation. Methods and Materials: Phantom and patient cases were studied. Plans were generated with varying combinations of field width (FW), pitch, and modulation factor (MF) to administer 200 cGy per fraction to the planning target in eight subfractions, thereby mimicking the technique used on conventional linacs. Plans were compared using dose-volume histograms, homogeneity indices, conformation numbers, and treatment time. Plan delivery quality assurance was performed to assess deliverability. Results: It was observed that for helical tomotherapy, intrinsic limitations in leaf open time in the multileaf collimator deteriorate plan quality and deliverability substantially when attempting to deliver very low doses such as 20-40 cGy. The various permutations evaluated revealed that the combination of small FW (1.0 cm), small MF (1.3-1.5), and large pitch (∼0.86), along with the half-gantry-angle-blocked scheme, can generate clinically acceptable plans with acceptable delivery accuracy (±3%). Conclusion: Pulsed reduced dose-rate radiotherapy can be accurately delivered using helical tomotherapy for tumor reirradiation when the appropriate combination of FW, MF, and pitch is used.

  8. An absolute dose determination of helical tomotherapy accelerator, TomoTherapy High-Art II

    International Nuclear Information System (INIS)

    Bailat, Claude J.; Buchillier, Thierry; Pachoud, Marc; Moeckli, Raphaeel; Bochud, Francois O.

    2009-01-01

    Purpose: A helical tomotherapy accelerator presents a dosimetric challenge because, to this day, there is no internationally accepted protocol for the determination of the absolute dose. Because of this reality, we investigated the different alternatives for characterizing and measuring the absolute dose of such an accelerator. We tested several dosimetric techniques with various metrological traceabilities as well as using a number of phantoms in static and helical modes. Methods: Firstly, the relationship between the reading of ionization chambers and the absorbed dose is dependent on the beam quality value of the photon beam. For high energy photons, the beam quality is specified by the tissue phantom ratio (TPR 20,10 ) and it is therefore necessary to know the TPR 20,10 to calculate the dose delivered by a given accelerator. This parameter is obtained through the ratio of the absorbed dose at 20 and 10 cm depths in water and was measured in the particular conditions of the tomotherapy accelerator. Afterward, measurements were performed using the ionization chamber (model A1SL) delivered as a reference instrument by the vendor. This chamber is traceable in absorbed dose to water in a Co-60 beam to a water calorimeter of the American metrology institute (NIST). Similarly, in Switzerland, each radiotherapy department is directly traceable to the Swiss metrology institute (METAS) in absorbed dose to water based on a water calorimeter. For our research, this traceability was obtained by using an ionization chamber traceable to METAS (model NE 2611A), which is the secondary standard of our institute. Furthermore, in order to have another fully independent measurement method, we determined the dose using alanine dosimeters provided by and traceable to the British metrology institute (NPL); they are calibrated in absorbed dose to water using a graphite calorimeter. And finally, we wanted to take into account the type of chamber routinely used in clinical practice and

  9. Stereotactic Image-Guided Intensity Modulated Radiotherapy Using the HI-ART II Helical Tomotherapy System

    International Nuclear Information System (INIS)

    Holmes, Timothy W.; Hudes, Richard; Dziuba, Sylwester; Kazi, Abdul; Hall, Mark; Dawson, Dana

    2008-01-01

    The highly integrated adaptive radiation therapy (HI-ART II) helical tomotherapy unit is a new radiotherapy machine designed to achieve highly precise and accurate treatments at all body sites. The precision and accuracy of the HI-ART II is similar to that provided by stereotactic radiosurgery systems, hence the historical distinction between external beam radiotherapy and stereotactic procedures based on differing precision requirements is removed for this device. The objectives of this work are: (1) to describe stereotactic helical tomotherapy processes (SRS, SBRT); (2) to show that the precision and accuracy of the HI-ART meet the requirements defined for SRS and SBRT; and (3) to describe the clinical implementation of a stereotactic image-guided intensity modulated radiation therapy (IG-IMRT) system that incorporates optical motion management

  10. Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate

    International Nuclear Information System (INIS)

    Ha, Jin Sook; Chung, Yoon Sun; Lee, Ik Jae; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Jeon, Mi Jin; Chok, Yoon Jin; Kim, Ki Kwang; Lee, Seul Bee

    2011-01-01

    Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector (√x 2 +√y 2 +√z 2 ) value for assessing overall movement. Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group

  11. Helical tomotherapy shielding calculation for an existing LINAC treatment room: sample calculation and cautions

    International Nuclear Information System (INIS)

    Wu Chuan; Guo Fanqing; Purdy, James A

    2006-01-01

    This paper reports a step-by-step shielding calculation recipe for a helical tomotherapy unit (TomoTherapy Inc., Madison, WI, USA), recently installed in an existing Varian 600C treatment room. Both primary and secondary radiations (leakage and scatter) are explicitly considered. A typical patient load is assumed. Use factor is calculated based on an analytical formula derived from the tomotherapy rotational beam delivery geometry. Leakage and scatter are included in the calculation based on corresponding measurement data as documented by TomoTherapy Inc. Our calculation result shows that, except for a small area by the therapists' console, most of the existing Varian 600C shielding is sufficient for the new tomotherapy unit. This work cautions other institutions facing the similar situation, where an HT unit is considered for an existing LINAC treatment room, more secondary shielding might be considered at some locations, due to the significantly increased secondary shielding requirement by HT. (note)

  12. Evaluation of image-guided helical tomotherapy for the retreatment of spinal metastasis

    International Nuclear Information System (INIS)

    Mahan, Stephen L.; Ramsey, Chester R.; Scaperoth, Daniel D.; Chase, Daniel J.; Byrne, Thomas E.

    2005-01-01

    Introduction: Patients with vertebral metastasis that receive radiation therapy are typically treated to the spinal cord tolerance dose. As such, it is difficult to successfully deliver a second course of radiation therapy for patients with overlapping treatment volumes. In this study, an image-guided helical tomotherapy system was evaluated for the retreatment of previously irradiated vertebral metastasis. Methods and Materials: Helical tomotherapy dose gradients and maximum cord doses were measured in a cylindrical phantom for geometric test cases with separations between the planning target volume (PTV) and the spinal cord organ at risk (OAR) of 2 mm, 4 mm, 6 mm, 8 mm, and 10 mm. Megavoltage computed tomography (CT) images were examined for their ability to localize spinal anatomy for positioning purposes by repeat imaging of the cervical spine in an anthropomorphic phantom. In addition to the phantom studies, 8 patients with cord compressions that had received previous radiation therapy were retreated to a mean dose of 28 Gy using conventional fractionation. Results and Discussion: Megavoltage CT images were capable of positioning an anthropomorphic phantom to within ±1.2 mm (2σ) superior-inferiorly and within ±0.6 mm (2σ) anterior-posteriorly and laterally. Dose gradients of 10% per mm were measured in phantom while PTV uniformity indices of less than 11% were maintained. The calculated maximum cord dose was 25% of the prescribed dose for a 10-mm PTV-to-OAR separation and 71% of the prescribed dose for a PTV-to-OAR separation of 2 mm. Eight patients total have been treated without radiation-induced myelopathy or any other adverse effects from treatment. Conclusions: A technique has been evaluated for the retreatment of vertebral metastasis using image-guided helical tomotherapy. Phantom and patient studies indicated that a tomotherapy system is capable of delivering dose gradients of 10% per mm and positioning the patient within 1.2 mm without the use of

  13. Parotid Gland Sparing With Helical Tomotherapy in Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Voordeckers, Mia; Farrag, Ashraf; Everaert, Hendrik; Tournel, Koen; Storme, Guy; Verellen, Dirk; De Ridder, Mark

    2012-01-01

    Purpose: This study evaluated the ability of helical tomotherapy to spare the function of the parotid glands in patients with head-and-neck cancer by analyzing dose–volume histograms, salivary gland scintigraphy, and quality of life assessment. Methods and Materials: Data from 76 consecutive patients treated with helical tomotherapy (Hi-Art Tomotherapy) at University Hospital Brussel were analyzed. During planning, priority was given to planning target volume (PTV) coverage: ≥95% of the dose must be delivered to ≥95% of the PTV. Elective nodal regions received 54 Gy (1.8 Gy/fraction). A dose of 70.5 Gy (2.35 Gy/fraction) was prescribed to the primary tumor and pathologic lymph nodes (simultaneous integrated boost scheme). Objective scoring of salivary excretion was performed by salivary gland scintigraphy. Subjective scoring of salivary gland function was evaluated by the European Organization for Research and Treatment of Cancer quality of life questionnaires Quality of Life Questionnaire—C30 (QLQ-C30) and Quality of Life Questionnaire—Head and Neck 35 (H and N35). Results: Analysis of dose–volume histograms (DVHs) showed excellent coverage of the PTV. The volume of PTV receiving 95% of the prescribed dose (V95%) was 99.4 (range, 96.3–99.9). DVH analysis of parotid gland showed a median value of the mean parotid dose of 32.1 Gy (range, 17.5–70.3 Gy). The median parotid volume receiving a dose <26 Gy was 51.2%. Quality of life evaluation demonstrated an initial deterioration of almost all scales and items in QLQ-C30 and QLQ-H and N35. Most items improved in time, and some reached baseline values 18 months after treatment. Conclusion: DVH analysis, scintigraphic evaluation of parotid function, and quality of life assessment of our patient group showed that helical tomotherapy makes it possible to preserve parotid gland function without compromising disease control. We recommend mean parotid doses of <34 Gy and doses <26 Gy to a maximum 47% of the

  14. Performance characteristics of an independent dose verification program for helical tomotherapy

    Directory of Open Access Journals (Sweden)

    Isaac C. F. Chang

    2017-01-01

    Full Text Available Helical tomotherapy with its advanced method of intensity-modulated radiation therapy delivery has been used clinically for over 20 years. The standard delivery quality assurance procedure to measure the accuracy of delivered radiation dose from each treatment plan to a phantom is time-consuming. RadCalc®, a radiotherapy dose verification software, has released specifically for beta testing a module for tomotherapy plan dose calculations. RadCalc®'s accuracy for tomotherapy dose calculations was evaluated through examination of point doses in ten lung and ten prostate clinical plans. Doses calculated by the TomoHDA™ tomotherapy treatment planning system were used as the baseline. For lung cases, RadCalc® overestimated point doses in the lung by an average of 13%. Doses within the spinal cord and esophagus were overestimated by 10%. Prostate plans showed better agreement, with overestimations of 6% in the prostate, bladder, and rectum. The systematic overestimation likely resulted from limitations of the pencil beam dose calculation algorithm implemented by RadCalc®. Limitations were more severe in areas of greater inhomogeneity and less prominent in regions of homogeneity with densities closer to 1 g/cm3. Recommendations for RadCalc® dose calculation algorithms and anatomical representation were provided based on the results of the study.

  15. Simultaneous Multitarget Irradiation Using Helical Tomotherapy for Advanced Hepatocellular Carcinoma With Multiple Extrahepatic Metastases

    International Nuclear Information System (INIS)

    Jang, Jeong Won; Kay, Chul Seung; You, Chan Ran; Kim, Chang Wook; Bae, Si Hyun.; Choi, Jong Young; Yoon, Seung Kew; Han, Chi Wha; Jung, Hyun Suk; Choi, Ihl Bong

    2009-01-01

    Purpose: The prognosis of hepatocellular carcinoma (HCC) patients with extrahepatic metastases is extremely poor. Helical tomotherapy, an image-guided, intensity-modulated radiotherapy system, can allow for simultaneous and precise targeting of multiple cancerous lesions, while sparing normal tissues. This study evaluated the feasibility and outcome of tomotherapy for advanced HCC with metastases. Patients and Methods: A total of 42 consecutive HCC patients with metastases were treated with tomotherapy using the Hi-Art system. A total of 152 intra- and extrahepatic lesions (3.5 lesions/patient) were treated simultaneously, with a dose of 51.03 Gy (range, 30-57.61) in 10 fractions. Transarterial chemolipiodolization using epirubicin (50 mg) and cisplatin (60 mg) was repeated in patients with intrahepatic HCC (mean size, 9.0 cm) after tomotherapy. Results: An objective response (complete response and partial response) was achieved in 45.2% of patients with intrahepatic tumors, 68.4% of patients with pulmonary lesions, 60.0% of patients with lymph node/adrenal lesions, and 66.7% of patients with soft-tissue metastases. The complete response rate for those with pulmonary and lymph node/adrenal metastases was 26.3% and 5.0%, respectively. The overall survival rate at 1 and 2 years was 50.1% and 14.9%, respectively, with a median survival of 12.3 months. The actuarial in-field tumor control rate for ≤1 year was 79.0%. No cases of Grade 4-5 acute toxicity occurred. Conclusion: The results of this study have shown that helical tomotherapy is safe and feasible without major toxicities for the treatment of advanced HCC and results in excellent tumor control and a potential survival benefit. This approach is expected to be a useful palliative option for selected HCC patients with metastases.

  16. Hippocampal-Sparing Whole-Brain Radiotherapy: A 'How-To' Technique Using Helical Tomotherapy and Linear Accelerator-Based Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Gondi, Vinai; Tolakanahalli, Ranjini; Mehta, Minesh P.; Tewatia, Dinesh; Rowley, Howard; Kuo, John S.; Khuntia, Deepak; Tome, Wolfgang A.

    2010-01-01

    Purpose: Sparing the hippocampus during cranial irradiation poses important technical challenges with respect to contouring and treatment planning. Herein we report our preliminary experience with whole-brain radiotherapy using hippocampal sparing for patients with brain metastases. Methods and Materials: Five anonymous patients previously treated with whole-brain radiotherapy with hippocampal sparing were reviewed. The hippocampus was contoured, and hippocampal avoidance regions were created using a 5-mm volumetric expansion around the hippocampus. Helical tomotherapy and linear accelerator (LINAC)-based intensity-modulated radiotherapy (IMRT) treatment plans were generated for a prescription dose of 30 Gy in 10 fractions. Results: On average, the hippocampal avoidance volume was 3.3 cm 3 , occupying 2.1% of the whole-brain planned target volume. Helical tomotherapy spared the hippocampus, with a median dose of 5.5 Gy and maximum dose of 12.8 Gy. LINAC-based IMRT spared the hippocampus, with a median dose of 7.8 Gy and maximum dose of 15.3 Gy. On a per-fraction basis, mean dose to the hippocampus (normalized to 2-Gy fractions) was reduced by 87% to 0.49 Gy 2 using helical tomotherapy and by 81% to 0.73 Gy 2 using LINAC-based IMRT. Target coverage and homogeneity was acceptable with both IMRT modalities, with differences largely attributed to more rapid dose fall-off with helical tomotherapy. Conclusion: Modern IMRT techniques allow for sparing of the hippocampus with acceptable target coverage and homogeneity. Based on compelling preclinical evidence, a Phase II cooperative group trial has been developed to test the postulated neurocognitive benefit.

  17. Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass

    International Nuclear Information System (INIS)

    Wong, J.H.D.; Rosenfeld, A.B.; Hardcastle, N.; Bayliss, A.; Tolakanahalli, R.; Tome, W.

    2010-01-01

    Full text: Helical tomotherapy presents a new paradigm in cancer treatment integrating image guidance and intensity modulated radiation therapy in one system. Many of the tomotherapy QAs involve using the MYCT detector to QA the unit itself. Although convenient, they lack independence from the system under measurement. This work describes the use of a novel silicon detector as an independent tool for tomotherapy QA. The dose magnifying glass (DMG) is a 128 channel array of Si strip detectors. It was used to measure three tomotherapy QA parameters, (a) MLC alignment, (b) leaf latency and (c) leaf output factor (LOF). MLC alignment test measures the alignment of the MLC bank and the gantry center of rotation. Leaf latency is defined as the time taken for the leaf to travel from a closed state to an open state (and vice versa). Measurement are acquired at a 3 ms sampling rate with the detector pitch of 0.2 mm. Leaf latency for 50-400 ms projection time were measured. LOF measures the effect of the state of the adjacent leaves on a selected leaf of interest. For the tomotherapy unit tested, the DMG measured a 1.3 mm misalignment in the MLC alignment test. The leaf latency (Fig. I) shows a large non linearity in projection times <200 ms. The DMG measured a LOF of up to 25.3% when both adjacent leaves were opened. DMG with its high spatial and temporal resolutions presents a unique and independent tool for measuring selected tomotherapy QA parameters. (author)

  18. Clinic results of 121 nasopharyngeal carcinoma patients treated by helical tomotherapy

    International Nuclear Information System (INIS)

    Du Lei; Ma Lin; Feng Linchun; Zhou Guixia; Qu Baolin; Ren Gang; Xu Shouping; Xie Chuanbin; Zhang Xinxin; Li Fang

    2012-01-01

    Objective: To summarize the outcome of nasopharyngeal carcinoma (NPC) treated by helical tomotherapy in the Chinese PLA general hospital. Methods: Between September 2007 and August 2010, 121 newly diagnosed NPC patients were treated by radiotherapy with Tomotherapy system, with (n =90) or without (n = 31) concurrent chemotherapy or molecular target therapy. The prescription dose was 70 - 74 Gy/33f to primary tumor and positive lymph node planning target volume, 60.0 - 62.7 Gy/33f to high risk planning target volume, and 52 -56 Gy/33f to low risk planning target volume. Acute side-effects were evaluated with RTOG/EORTC criteria. Results: The remission rate of primary lesion and positive lymph nodes was 95.0% and 99.0%, respectively. The follow-up rate was 100%. The number of patients with 1, 2 and 3 years followed-up were 99, 49, and 7. The 1-, 2-and 3-year local relapse-free survival rates were 97.30%, 97.3% and 97.3%, respectively. The 1-, 2-and 3-year nodal relapse-free survival rates were 100%, 100% and 100%, respectively. The 1-, 2-and 3-year distant metastasis-free survival rates were 98.4%, 96.3% and 96.3%, respectively. The 1-, 2-and 3-year overall survival rates were 96.5%, 92.6% and 86.8%, respectively. Acute toxicities of skin, oral mucosa and xerostomia with grade 0, 1, 2 and 3 were 5.0%, 74.4%, 15.7% and 4.9%; 0.8%, 37.2%, 57.9% and 4.1%; 3.3%, 53.7%, 43.0% and 0%, respectively. Xerostomia restored with time, no grade 2 or more xerostomia was observed 1 year after radiation therapy. Concurrent chemotherapy significantly increased incidence of mucositis, esophagitis and tracheitis. Conclusion: Helical tomotherapy is efficient, secure and effective modality for the treatment of nasopharyngeal carcinoma. (authors)

  19. Should helical tomotherapy replace brachytherapy for cervical cancer? Case report.

    Science.gov (United States)

    Hsieh, Chen-Hsi; Wei, Ming-Chow; Hsu, Yao-Peng; Chong, Ngot-Swan; Chen, Yu-Jen; Hsiao, Sheng-Mou; Hsieh, Yen-Ping; Wang, Li-Ying; Shueng, Pei-Wei

    2010-11-23

    Stereotactic body radiation therapy (SBRT) administered via a helical tomotherapy (HT) system is an effective modality for treating lung cancer and metastatic liver tumors. Whether SBRT delivered via HT is a feasible alternative to brachytherapy in treatment of locally advanced cervical cancer in patients with unusual anatomic configurations of the uterus has never been studied. A 46-year-old woman presented with an 8-month history of abnormal vaginal bleeding. Biopsy revealed squamous cell carcinoma of the cervix. Magnetic resonance imaging (MRI) showed a cervical tumor with direct invasion of the right parametrium, bilateral hydronephrosis, and multiple uterine myomas. International Federation of Gynecology and Obstetrics (FIGO) stage IIIB cervical cancer was diagnosed. Concurrent chemoradiation therapy (CCRT) followed by SBRT delivered via HT was administered instead of brachytherapy because of the presence of multiple uterine myomas with bleeding tendency. Total abdominal hysterectomy was performed after 6 weeks of treatment because of the presence of multiple uterine myomas. Neither pelvic MRI nor results of histopathologic examination at X-month follow-up showed evidence of tumor recurrence. Only grade 1 nausea and vomiting during treatment were noted. Lower gastrointestinal bleeding was noted at 14-month follow-up. No fistula formation and no evidence of haematological, gastrointestinal or genitourinary toxicities were noted on the most recent follow-up. CCRT followed by SBRT appears to be an effective and safe modality for treatment of cervical cancer. Larger-scale studies are warranted.

  20. Should helical tomotherapy replace brachytherapy for cervical cancer? Case report

    Directory of Open Access Journals (Sweden)

    Chen Yu-Jen

    2010-11-01

    Full Text Available Abstract Background Stereotactic body radiation therapy (SBRT administered via a helical tomotherapy (HT system is an effective modality for treating lung cancer and metastatic liver tumors. Whether SBRT delivered via HT is a feasible alternative to brachytherapy in treatment of locally advanced cervical cancer in patients with unusual anatomic configurations of the uterus has never been studied. Case Presentation A 46-year-old woman presented with an 8-month history of abnormal vaginal bleeding. Biopsy revealed squamous cell carcinoma of the cervix. Magnetic resonance imaging (MRI showed a cervical tumor with direct invasion of the right parametrium, bilateral hydronephrosis, and multiple uterine myomas. International Federation of Gynecology and Obstetrics (FIGO stage IIIB cervical cancer was diagnosed. Concurrent chemoradiation therapy (CCRT followed by SBRT delivered via HT was administered instead of brachytherapy because of the presence of multiple uterine myomas with bleeding tendency. Total abdominal hysterectomy was performed after 6 weeks of treatment because of the presence of multiple uterine myomas. Neither pelvic MRI nor results of histopathologic examination at X-month follow-up showed evidence of tumor recurrence. Only grade 1 nausea and vomiting during treatment were noted. Lower gastrointestinal bleeding was noted at 14-month follow-up. No fistula formation and no evidence of haematological, gastrointestinal or genitourinary toxicities were noted on the most recent follow-up. Conclusions CCRT followed by SBRT appears to be an effective and safe modality for treatment of cervical cancer. Larger-scale studies are warranted.

  1. Should helical tomotherapy replace brachytherapy for cervical cancer? Case report

    International Nuclear Information System (INIS)

    Hsieh, Chen-Hsi; Wei, Ming-Chow; Hsu, Yao-Peng; Chong, Ngot-Swan; Chen, Yu-Jen; Hsiao, Sheng-Mou; Hsieh, Yen-Ping; Wang, Li-Ying; Shueng, Pei-Wei

    2010-01-01

    Stereotactic body radiation therapy (SBRT) administered via a helical tomotherapy (HT) system is an effective modality for treating lung cancer and metastatic liver tumors. Whether SBRT delivered via HT is a feasible alternative to brachytherapy in treatment of locally advanced cervical cancer in patients with unusual anatomic configurations of the uterus has never been studied. A 46-year-old woman presented with an 8-month history of abnormal vaginal bleeding. Biopsy revealed squamous cell carcinoma of the cervix. Magnetic resonance imaging (MRI) showed a cervical tumor with direct invasion of the right parametrium, bilateral hydronephrosis, and multiple uterine myomas. International Federation of Gynecology and Obstetrics (FIGO) stage IIIB cervical cancer was diagnosed. Concurrent chemoradiation therapy (CCRT) followed by SBRT delivered via HT was administered instead of brachytherapy because of the presence of multiple uterine myomas with bleeding tendency. Total abdominal hysterectomy was performed after 6 weeks of treatment because of the presence of multiple uterine myomas. Neither pelvic MRI nor results of histopathologic examination at X-month follow-up showed evidence of tumor recurrence. Only grade 1 nausea and vomiting during treatment were noted. Lower gastrointestinal bleeding was noted at 14-month follow-up. No fistula formation and no evidence of haematological, gastrointestinal or genitourinary toxicities were noted on the most recent follow-up. CCRT followed by SBRT appears to be an effective and safe modality for treatment of cervical cancer. Larger-scale studies are warranted

  2. Independent calculation of dose distributions for helical tomotherapy using a conventional treatment planning system

    Energy Technology Data Exchange (ETDEWEB)

    Klüter, Sebastian, E-mail: sebastian.klueter@med.uni-heidelberg.de; Schubert, Kai; Lissner, Steffen; Sterzing, Florian; Oetzel, Dieter; Debus, Jürgen [Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany, and Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany, and German Consortium for Translational Cancer Research (DKTK), Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Schlegel, Wolfgang [German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Oelfke, Uwe [German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London SM2 5NG (United Kingdom); Nill, Simeon [Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London SM2 5NG (United Kingdom)

    2014-08-15

    Purpose: The dosimetric verification of treatment plans in helical tomotherapy usually is carried out via verification measurements. In this study, a method for independent dose calculation of tomotherapy treatment plans is presented, that uses a conventional treatment planning system with a pencil kernel dose calculation algorithm for generation of verification dose distributions based on patient CT data. Methods: A pencil beam algorithm that directly uses measured beam data was configured for dose calculation for a tomotherapy machine. Tomotherapy treatment plans were converted into a format readable by an in-house treatment planning system by assigning each projection to one static treatment field and shifting the calculation isocenter for each field in order to account for the couch movement. The modulation of the fluence for each projection is read out of the delivery sinogram, and with the kernel-based dose calculation, this information can directly be used for dose calculation without the need for decomposition of the sinogram. The sinogram values are only corrected for leaf output and leaf latency. Using the converted treatment plans, dose was recalculated with the independent treatment planning system. Multiple treatment plans ranging from simple static fields to real patient treatment plans were calculated using the new approach and either compared to actual measurements or the 3D dose distribution calculated by the tomotherapy treatment planning system. In addition, dose–volume histograms were calculated for the patient plans. Results: Except for minor deviations at the maximum field size, the pencil beam dose calculation for static beams agreed with measurements in a water tank within 2%/2 mm. A mean deviation to point dose measurements in the cheese phantom of 0.89% ± 0.81% was found for unmodulated helical plans. A mean voxel-based deviation of −0.67% ± 1.11% for all voxels in the respective high dose region (dose values >80%), and a mean local

  3. Independent calculation of dose distributions for helical tomotherapy using a conventional treatment planning system

    International Nuclear Information System (INIS)

    Klüter, Sebastian; Schubert, Kai; Lissner, Steffen; Sterzing, Florian; Oetzel, Dieter; Debus, Jürgen; Schlegel, Wolfgang; Oelfke, Uwe; Nill, Simeon

    2014-01-01

    Purpose: The dosimetric verification of treatment plans in helical tomotherapy usually is carried out via verification measurements. In this study, a method for independent dose calculation of tomotherapy treatment plans is presented, that uses a conventional treatment planning system with a pencil kernel dose calculation algorithm for generation of verification dose distributions based on patient CT data. Methods: A pencil beam algorithm that directly uses measured beam data was configured for dose calculation for a tomotherapy machine. Tomotherapy treatment plans were converted into a format readable by an in-house treatment planning system by assigning each projection to one static treatment field and shifting the calculation isocenter for each field in order to account for the couch movement. The modulation of the fluence for each projection is read out of the delivery sinogram, and with the kernel-based dose calculation, this information can directly be used for dose calculation without the need for decomposition of the sinogram. The sinogram values are only corrected for leaf output and leaf latency. Using the converted treatment plans, dose was recalculated with the independent treatment planning system. Multiple treatment plans ranging from simple static fields to real patient treatment plans were calculated using the new approach and either compared to actual measurements or the 3D dose distribution calculated by the tomotherapy treatment planning system. In addition, dose–volume histograms were calculated for the patient plans. Results: Except for minor deviations at the maximum field size, the pencil beam dose calculation for static beams agreed with measurements in a water tank within 2%/2 mm. A mean deviation to point dose measurements in the cheese phantom of 0.89% ± 0.81% was found for unmodulated helical plans. A mean voxel-based deviation of −0.67% ± 1.11% for all voxels in the respective high dose region (dose values >80%), and a mean local

  4. Clinical Study of Nasopharyngeal Carcinoma Treated by Helical Tomotherapy in China: 5-Year Outcomes

    Directory of Open Access Journals (Sweden)

    Lei Du

    2014-01-01

    Full Text Available Background. To evaluate the outcomes of nasopharyngeal carcinoma (NPC patients treated with helical tomotherapy (HT. Methods. Between September 2007 and August 2012, 190 newly diagnosed NPC patients were treated with HT. Thirty-one patients were treated with radiation therapy as single modality, 129 with additional cisplatin-based chemotherapy with or without anti-EGFR monoclonal antibody therapy, and 30 with concurrent anti-EGFR monoclonal antibody therapy. Results. Acute radiation related side effects were mainly grade 1 or 2. Grade 3 and greater toxicities were rarely noted. The median followup was 32 (3–38 months. The local relapse-free survival (LRFS, nodal relapse-free survival (NRFS, distant metastasis-free survival (DMFS, and overall survival (OS were 96.1%, 98.2%, 92.0%, and 86.3%, respectively, at 3 years. Cox multivariate regression analysis showed that age and T stage were independent predictors for 3-year OS. Conclusions. Helical tomotherapy for NPC patients achieved excellent 3-year locoregional control, distant metastasis-free survival, and overall survival, with relatively minor acute and late toxicities. Age and T stage were the main prognosis factors.

  5. Technical Note: Output and energy fluctuations of the tomotherapy Hi-Art helical tomotherapy system

    International Nuclear Information System (INIS)

    Mahan, Stephen L.; Chase, Daniel J.; Ramsey, Chester R.

    2004-01-01

    The output and energy calibrations for the first clinical Hi-Art 2.0 helical tomotherapy system have been reviewed. Fixed-gantry/fixed-couch and rotational-gantry/fixed-couch measurements were made on a daily basis over a period of 20 weeks to investigate system stability. Static gantry measurements were taken at 10 cm depth in a rectangular stack of Virtual Water at an SSD distance of 90 cm and a field size of 5x40 cm. Rotational gantry measurements were taken in a cylindrical phantom Virtual Water phantom for a field size of 5x40 cm. The Hi-Art 2.0 system has maintained its calibration to within ±2% and energy to within ±1.5% over the initial 20 week period

  6. Preliminary comp arison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity

    International Nuclear Information System (INIS)

    Blasi, Olivier; Fontenot, Jonas D; Fields, Robert S; Gibbons, John P; Hogstrom, Kenneth R

    2011-01-01

    To investigate combining unmodulated electron beams with intensity-modulated radiation therapy to improve dose distributions for superficial head and neck cancers, and to compare mixed beam plans with helical tomotherapy. Mixed beam and helical tomotherapy dose plans were developed for two patients with parotid gland tumors and two patients with nasal cavity tumors. Mixed beam plans consisted of various weightings of a enface electron beam and IMRT, which was optimized after calculation of the electron dose to compensate for heterogeneity in the electron dose distribution within the target volume. Helical tomotherapy plans showed dose conformity and homogeneity in the target volume that was equal to or better than the mixed beam plans. Electron-only plans tended to show the lowest doses to normal tissues, but with markedly worse dose conformity and homogeneity than in the other plans. However, adding a 20% IMRT dose fraction (i.e., IMRT:electron weighting = 1:4) to the electron plan restored target conformity and homogeneity to values comparable to helical tomotherapy plans, while maintaining lower normal tissue dose. Mixed beam treatments offer some dosimetric advantages over IMRT or helical tomotherapy for target depths that do not exceed the useful range of the electron beam. Adding a small IMRT component (e.g., IMRT:electron weighting = 1:4) to electron beam plans markedly improved target dose homogeneity and conformity for the cases examined in this study

  7. Verification of helical tomotherapy delivery using autoassociative kernel regression

    International Nuclear Information System (INIS)

    Seibert, Rebecca M.; Ramsey, Chester R.; Garvey, Dustin R.; Wesley Hines, J.; Robison, Ben H.; Outten, Samuel S.

    2007-01-01

    Quality assurance (QA) is a topic of major concern in the field of intensity modulated radiation therapy (IMRT). The standard of practice for IMRT is to perform QA testing for individual patients to verify that the dose distribution will be delivered to the patient. The purpose of this study was to develop a new technique that could eventually be used to automatically evaluate helical tomotherapy treatments during delivery using exit detector data. This technique uses an autoassociative kernel regression (AAKR) model to detect errors in tomotherapy delivery. AAKR is a novel nonparametric model that is known to predict a group of correct sensor values when supplied a group of sensor values that is usually corrupted or contains faults such as machine failure. This modeling scheme is especially suited for the problem of monitoring the fluence values found in the exit detector data because it is able to learn the complex detector data relationships. This scheme still applies when detector data are summed over many frames with a low temporal resolution and a variable beam attenuation resulting from patient movement. Delivery sequences from three archived patients (prostate, lung, and head and neck) were used in this study. Each delivery sequence was modified by reducing the opening time for random individual multileaf collimator (MLC) leaves by random amounts. The error and error-free treatments were delivered with different phantoms in the path of the beam. Multiple autoassociative kernel regression (AAKR) models were developed and tested by the investigators using combinations of the stored exit detector data sets from each delivery. The models proved robust and were able to predict the correct or error-free values for a projection, which had a single MLC leaf decrease its opening time by less than 10 msec. The model also was able to determine machine output errors. The average uncertainty value for the unfaulted projections ranged from 0.4% to 1.8% of the detector

  8. A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy

    International Nuclear Information System (INIS)

    Boswell, Sarah A.; Jeraj, Robert; Ruchala, Kenneth J.; Olivera, Gustavo H.; Jaradat, Hazim A.; James, Joshua A.; Gutierrez, Alonso; Pearson, Dave; Frank, Gary; Mackie, T. Rock

    2005-01-01

    An accurate means of determining and correcting for daily patient setup errors is important to the cancer outcome in radiotherapy. While many tools have been developed to detect setup errors, difficulty may arise in accurately adjusting the patient to account for the rotational error components. A novel, automated method to correct for rotational patient setup errors in helical tomotherapy is proposed for a treatment couch that is restricted to motion along translational axes. In tomotherapy, only a narrow superior/inferior section of the target receives a dose at any instant, thus rotations in the sagittal and coronal planes may be approximately corrected for by very slow continuous couch motion in a direction perpendicular to the scanning direction. Results from proof-of-principle tests indicate that the method improves the accuracy of treatment delivery, especially for long and narrow targets. Rotational corrections about an axis perpendicular to the transverse plane continue to be implemented easily in tomotherapy by adjustment of the initial gantry angle

  9. Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass

    International Nuclear Information System (INIS)

    Wong, J. H. D.; Hardcastle, N.; Tome, W. A.

    2011-01-01

    Purpose: Helical tomotherapy is a complex delivery technique, integrating CT image guidance and intensity modulated radiotherapy in a single system. The integration of the CT detector ring on the gantry not only allows patient position verification but is also often used to perform various QA procedures. This convenience lacks the rigor of a machine-independent QA process. Methods: In this article, a Si strip detector, known as the Dose Magnifying Glass (DMG), was used to perform machine-independent QA measurements of the multileaf collimator alignment, leaf open time threshold, and leaf fluence output factor (LFOF). Results: The DMG measurements showed good agreements with EDR2 film for the MLC alignment test while the CT detector agrees well with DMG measurements for leaf open time threshold and LFOF measurements. The leaf open time threshold was found to be approximately 20 ms. The LFOF measured with the DMG agreed within error with the CT detector measured LFOF. Conclusions: The DMG with its 0.2 mm spatial resolution coupled to TERA ASIC allowed real-time high temporal resolution measurements of the tomotherapy leaf movement. In conclusion, DMG was shown to be a suitable tool for machine-independent QA of a tomotherapy unit.

  10. Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass.

    Science.gov (United States)

    Wong, J H D; Hardcastle, N; Tomé, W A; Bayliss, A; Tolakanahalli, R; Lerch, M L F; Petasecca, M; Carolan, M; Metcalfe, P; Rosenfeld, A B

    2011-04-01

    Helical tomotherapy is a complex delivery technique, integrating CT image guidance and intensity modulated radiotherapy in a single system. The integration of the CT detector ring on the gantry not only allows patient position verification but is also often used to perform various QA procedures. This convenience lacks the rigor of a machine-independent QA process. In this article, a Si strip detector, known as the Dose Magnifying Glass (DMG), was used to perform machine-independent QA measurements of the multileaf collimator alignment, leaf open time threshold, and leaf fluence output factor (LFOF). The DMG measurements showed good agreements with EDR2 film for the MLC alignment test while the CT detector agrees well with DMG measurements for leaf open time threshold and LFOF measurements. The leaf open time threshold was found to be approximately 20 ms. The LFOF measured with the DMG agreed within error with the CT detector measured LFOF. The DMG with its 0.2 mm spatial resolution coupled to TERA ASIC allowed real-time high temporal resolution measurements of the tomotherapy leaf movement. In conclusion, DMG was shown to be a suitable tool for machine-independent QA of a tomotherapy unit.

  11. Dosimetric aspects of breast radiotherapy with three-dimensional and intensity-modulated radiotherapy helical tomotherapy planning modules

    International Nuclear Information System (INIS)

    Yadav, Poonam; Yan, Yue; Ignatowski, Tasha; Olson, Anna

    2017-01-01

    In this work, we investigated the dosimetric differences between the intensity-modulated radiotherapy (IMRT) plans and the three-dimensional (3D) helical plans based on the TomoTherapy system. A total of 15 patients with supine setup were randomly selected from the data base. For patients with lumpectomy planning target volume (PTV), regional lymph nodes were also included as part of the target. For dose sparing, the significant differences between the helical IMRT and helical 3D were only found in the heart and contralateral breast. For the dose to the heart, helical IMRT reduced the maximum point dose by 6.98 Gy compared to the helical 3D plan (p = 0.01). For contralateral breast, the helical IMRT plans significantly reduced the maximum point dose by 5.6 Gy compared to the helical 3D plan. However, compared to the helical 3D plan, the helical IMRT plan increased the volume for lower dose (13.08% increase in V 5 Gy , p = 0.01). In general, there are no significant differences in dose sparing between helical IMRT and helical 3D plans.

  12. Split-Field Helical Tomotherapy With or Without Chemotherapy for Definitive Treatment of Cervical Cancer

    International Nuclear Information System (INIS)

    Chang, Albert J.; Richardson, Susan; Grigsby, Perry W.; Schwarz, Julie K.

    2012-01-01

    Objective: The objective of this study was to investigate the chronic toxicity, response to therapy, and survival outcomes of patients with cervical cancer treated with definitive pelvic irradiation delivered by helical tomotherapy (HT), with or without concurrent chemotherapy. Methods and Materials: There were 15 patients with a new diagnosis of cervical cancer evaluated in this study from April 2006 to February 2007. The clinical stages of their disease were Stage Ib1 in 3 patients, Ib2 in 3, IIa in 2, IIb in 4, IIIb in 2, and IVa in 1 patient. Fluorodeoxyglucose–positron emission tomography/computed tomography (FDG-PET/CT) simulation was performed in all patients. All patients received pelvic irradiation delivered by HT and high-dose-rate (HDR) brachytherapy. Four patients also received para-aortic irradiation delivered by HT. Thirteen patients received concurrent chemotherapy. Patients were monitored for chronic toxicity using the Common Terminology Criteria for Adverse Events version 3.0 criteria. Results: The median age of the cohort was 51 years (range, 29-87 years), and the median follow-up for all patients alive at time of last follow-up was 35 months. The median overall radiation treatment time was 54 days. One patient developed a chronic Grade 3 GI complication. No other Grade 3 or 4 complications were observed. At last follow-up, 3 patients had developed a recurrence, with 1 patient dying of disease progression. The 3-year progression-free and cause-specific survival estimates for all patients were 80% and 93%, respectively. Conclusion: Intensity-modulated radiation therapy delivered with HT and HDR brachytherapy with or without chemotherapy for definitive treatment of cervical cancer is feasible, with acceptable levels of chronic toxicity.

  13. Investigation of Accelerated Partial Breast Patient Alignment and Treatment With Helical Tomotherapy Unit

    International Nuclear Information System (INIS)

    Langen, Katja M.; Buchholz, Daniel J.; Burch, Doug R. C.; Burkavage, Rob C.; Limaye, Arti U.; Meeks, Sanford L.; Kupelian, Patrick A.; Ruchala, Kenneth J.; Haimerl, Jason; Henderson, Doug; Olivera, Gustavo H.

    2008-01-01

    Purpose: To determine the precision of megavoltage computed tomography (MVCT)-based alignment of the seroma cavity for patients undergoing partial breast irradiation; and to determine whether accelerated partial breast irradiation (APBI) plans can be generated for TomoTherapy deliveries that meet the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 protocol guidelines for target coverage and normal tissue dose limitations. Methods and Materials: We obtained 50 MVCT images from 10 patients. An interuser study was designed to assess the alignment precision. Using a standard helical and a fixed beam prototype ('topotherapy') optimizer, two APBI plans for each patient were developed. Results: The precision of the MVCT-based seroma cavity alignment was better than 2 mm if averaged over the patient population. Both treatment techniques could be used to generate acceptable APBI plans for patients that fulfilled the recommended NSABP B-39/RTOG-0413 selection criteria. For plans of comparable treatment time, the conformation of the prescription dose to the target was greater for helical deliveries, while the ipsilateral lung dose was significantly reduced for the topotherapy plans. Conclusions: The inherent volumetric imaging capabilities of a TomoTherapy Hi-Art unit allow for alignment of patients undergoing partial breast irradiation that is determined from the visibility of the seroma cavity on the MVCT image. The precision of the MVCT-based alignment was better than 2 mm (± standard deviation) when averaged over the patient population. Using the NSABP B-39/RTOG-0413 guidelines, acceptable APBI treatment plans can be generated using helical- or topotherapy-based delivery techniques

  14. Dosimetric aspects of breast radiotherapy with three-dimensional and intensity-modulated radiotherapy helical tomotherapy planning modules

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, Poonam [Department of Human Oncology, University of Wisconsin-Madison, Madison, WI (United States); Service of Radiation Therapy, University of Wisconsin Aspirus Cancer Center, Wisconsin Rapids, WI (United States); Yan, Yue, E-mail: yyan5@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Ignatowski, Tasha [Service of Radiation Therapy, University of Wisconsin Aspirus Cancer Center, Wisconsin Rapids, WI (United States); Olson, Anna [Department of Human Oncology, University of Wisconsin-Madison, Madison, WI (United States); Service of Radiation Therapy, University of Wisconsin Aspirus Cancer Center, Wisconsin Rapids, WI (United States)

    2017-04-01

    In this work, we investigated the dosimetric differences between the intensity-modulated radiotherapy (IMRT) plans and the three-dimensional (3D) helical plans based on the TomoTherapy system. A total of 15 patients with supine setup were randomly selected from the data base. For patients with lumpectomy planning target volume (PTV), regional lymph nodes were also included as part of the target. For dose sparing, the significant differences between the helical IMRT and helical 3D were only found in the heart and contralateral breast. For the dose to the heart, helical IMRT reduced the maximum point dose by 6.98 Gy compared to the helical 3D plan (p = 0.01). For contralateral breast, the helical IMRT plans significantly reduced the maximum point dose by 5.6 Gy compared to the helical 3D plan. However, compared to the helical 3D plan, the helical IMRT plan increased the volume for lower dose (13.08% increase in V{sub 5} {sub Gy}, p = 0.01). In general, there are no significant differences in dose sparing between helical IMRT and helical 3D plans.

  15. Calibration of helical tomotherapy machine using EPR/alanine dosimetry.

    Science.gov (United States)

    Perichon, Nicolas; Garcia, Tristan; François, Pascal; Lourenço, Valérie; Lesven, Caroline; Bordy, Jean-Marc

    2011-03-01

    Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10 x 10 cm2 square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40 x 5 cm2 defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) 60Co-gamma-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference 60Co-gamma-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then

  16. Clinical observation in nasopharyngeal carcinoma (NPC) treated with the anti-EGFR monoclonal antibody followed by helical tomotherapy

    International Nuclear Information System (INIS)

    Hou Jun; Feng Linchun; Cai Boning; Lu Na; Du Lei; Ma Lin; Xu Shouping; Xie Chuanbin

    2011-01-01

    Objective: To evaluate the clinical outcome and the acute toxicity in nasopharyngeal carcinoma (NPC) treated with tomotherapy followed by the anti-EGFR monoclonal antibody. Methods: Between March 2008 and November 2009, 34 newly diagnosed NPC patients were treated with helical tomotherapy combined with nimotuzumab or cetuximab. All the patients underwent tomotherapy at the dose of 70 Gy/33F for the gross tumor volume (pGTV ns ) and positive lymphnodes (GTV nd ), and 60 Gy/33F for the high risk clinical target volume (PTV 1 ), and 56 Gy/33 F for the low risk clinical target volume (PTV 2 ), respectively. 17 patients in group N were given weekly injection of 200 mg for 6-7 times and 17 patients in group C were given initial dosage 400 mg/m 2 followed by subsequent weekly dosage of 250 mg/m 2 for 6-7 times. Acute lesions were evaluated with the RTOG/EORTC criteria. Result: The median follow-up time was 22 months. The effective rates (CR + PR) in 3, 6 and 12 months were 14/17, 12/17, 12/17 in group N and 15/17, 14/17, 14/17 in group C. The 1 year survival rate was 15/17 in group Nand 17/17 in group C. Nimotuzumab had less acute mucositis reaction (u=2.25, P< 0.05), weight loss (t=2.56, P=0.02) and rash (u=4.36, P<0.01) compared with cetuximab. Conclusions: Helical tomotherapy combined with nimotuzumab or cetuximab was effective and made no difference in the short-term efficacy and 1 year survival rate for the patients with NPC. Nimotuzumab has less acute reaction than cetuximab. More studies should be done to prove long-term effects. (authors)

  17. Effects of megavoltage computed tomographic scan methodology on setup verification and adaptive dose calculation in helical TomoTherapy.

    Science.gov (United States)

    Zhu, Jian; Bai, Tong; Gu, Jiabing; Sun, Ziwen; Wei, Yumei; Li, Baosheng; Yin, Yong

    2018-04-27

    To evaluate the effect of pretreatment megavoltage computed tomographic (MVCT) scan methodology on setup verification and adaptive dose calculation in helical TomoTherapy. Both anthropomorphic heterogeneous chest and pelvic phantoms were planned with virtual targets by TomoTherapy Physicist Station and were scanned with TomoTherapy megavoltage image-guided radiotherapy (IGRT) system consisted of six groups of options: three different acquisition pitches (APs) of 'fine', 'normal' and 'coarse' were implemented by multiplying 2 different corresponding reconstruction intervals (RIs). In order to mimic patient setup variations, each phantom was shifted 5 mm away manually in three orthogonal directions respectively. The effect of MVCT scan options was analyzed in image quality (CT number and noise), adaptive dose calculation deviations and positional correction variations. MVCT scanning time with pitch of 'fine' was approximately twice of 'normal' and 3 times more than 'coarse' setting, all which will not be affected by different RIs. MVCT with different APs delivered almost identical CT numbers and image noise inside 7 selected regions with various densities. DVH curves from adaptive dose calculation with serial MVCT images acquired by varied pitches overlapped together, where as there are no significant difference in all p values of intercept & slope of emulational spinal cord (p = 0.761 & 0.277), heart (p = 0.984 & 0.978), lungs (p = 0.992 & 0.980), soft tissue (p = 0.319 & 0.951) and bony structures (p = 0.960 & 0.929) between the most elaborated and the roughest serials of MVCT. Furthermore, gamma index analysis shown that, compared to the dose distribution calculated on MVCT of 'fine', only 0.2% or 1.1% of the points analyzed on MVCT of 'normal' or 'coarse' do not meet the defined gamma criterion. On chest phantom, all registration errors larger than 1 mm appeared at superior-inferior axis, which cannot be avoided with the smallest AP and RI

  18. A virtual source model for Monte Carlo simulation of helical tomotherapy.

    Science.gov (United States)

    Yuan, Jiankui; Rong, Yi; Chen, Quan

    2015-01-08

    The purpose of this study was to present a Monte Carlo (MC) simulation method based on a virtual source, jaw, and MLC model to calculate dose in patient for helical tomotherapy without the need of calculating phase-space files (PSFs). Current studies on the tomotherapy MC simulation adopt a full MC model, which includes extensive modeling of radiation source, primary and secondary jaws, and multileaf collimator (MLC). In the full MC model, PSFs need to be created at different scoring planes to facilitate the patient dose calculations. In the present work, the virtual source model (VSM) we established was based on the gold standard beam data of a tomotherapy unit, which can be exported from the treatment planning station (TPS). The TPS-generated sinograms were extracted from the archived patient XML (eXtensible Markup Language) files. The fluence map for the MC sampling was created by incorporating the percentage leaf open time (LOT) with leaf filter, jaw penumbra, and leaf latency contained from sinogram files. The VSM was validated for various geometry setups and clinical situations involving heterogeneous media and delivery quality assurance (DQA) cases. An agreement of < 1% was obtained between the measured and simulated results for percent depth doses (PDDs) and open beam profiles for all three jaw settings in the VSM commissioning. The accuracy of the VSM leaf filter model was verified in comparing the measured and simulated results for a Picket Fence pattern. An agreement of < 2% was achieved between the presented VSM and a published full MC model for heterogeneous phantoms. For complex clinical head and neck (HN) cases, the VSM-based MC simulation of DQA plans agreed with the film measurement with 98% of planar dose pixels passing on the 2%/2 mm gamma criteria. For patient treatment plans, results showed comparable dose-volume histograms (DVHs) for planning target volumes (PTVs) and organs at risk (OARs). Deviations observed in this study were consistent

  19. Validation of a computational method for assessing the impact of intra-fraction motion on helical tomotherapy plans

    Energy Technology Data Exchange (ETDEWEB)

    Ngwa, Wilfred; Meeks, Sanford L; Kupelian, Patrick A; Langen, Katja M [Department of Radiation Oncology, M D Anderson Cancer Center Orlando, 1400 South Orange Avenue, Orlando, FL 32806 (United States); Schnarr, Eric [TomoTherapy, Inc., 1240 Deming Way, Madison, WI 53717 (United States)], E-mail: wilfred.ngwa@orlandohealth.com

    2009-11-07

    In this work, a method for direct incorporation of patient motion into tomotherapy dose calculations is developed and validated. This computational method accounts for all treatment dynamics and can incorporate random as well as cyclical motion data. Hence, interplay effects between treatment dynamics and patient motion are taken into account during dose calculation. This allows for a realistic assessment of intra-fraction motion on the dose distribution. The specific approach entails modifying the position and velocity events in the tomotherapy delivery plan to accommodate any known motion. The computational method is verified through phantom and film measurements. Here, measured prostate motion and simulated respiratory motion tracks were incorporated in the dose calculation. The calculated motion-encoded dose profiles showed excellent agreement with the measurements. Gamma analysis using 3 mm and 3% tolerance criteria showed over 97% and 96% average of points passing for the prostate and breathing motion tracks, respectively. The profile and gamma analysis results validate the accuracy of this method for incorporating intra-fraction motion into the dose calculation engine for assessment of dosimetric effects on helical tomotherapy dose deliveries.

  20. Comparison of IMRT Treatment Plans Between Linac and Helical Tomotherapy Based on Integral Dose and Inhomogeneity Index

    International Nuclear Information System (INIS)

    Shi Chengyu; Penagaricano, Jose; Papanikolaou, Niko

    2008-01-01

    Intensity modulated radiotherapy (IMRT) is an advanced treatment technology for radiation therapy. There are several treatment planning systems (TPS) that can generate IMRT plans. These plans may show different inhomogeneity indices to the planning target volume (PTV) and integral dose to organs at risk (OAR). In this study, we compared clinical cases covering different anatomical treatment sites, including head and neck, brain, lung, prostate, pelvis, and cranio-spinal axis. Two treatment plans were developed for each case using Pinnacle 3 and helical tomotherapy (HT) TPS. The inhomogeneity index of the PTV and the non-tumor integral dose (NTID) were calculated and compared for each case. Despite the difference in the number of effective beams, in several cases, NTID did not increase from HT as compared to the step-and-shoot delivery method. Six helical tomotherapy treatment plans for different treatment sites have been analyzed and compared against corresponding step-and-shoot plans generated with the Pinnacle 3 planning system. Results show that HT may produce plans with smaller integral doses to healthy organs, and fairly homogeneous doses to the target as compared to linac-based step-and-shoot IMRT planning in special treatment site such as cranio-spinal

  1. Pelvic tomo-therapy among 70 to 90 year old patients: feasibility and tolerance

    International Nuclear Information System (INIS)

    Bibault, J.E.; Nickers, P.; Castelain, B.; Lacornerie, T.; Reynaert, N.; Lartigau, E.

    2010-01-01

    As population is getting older (the number of people older than 70 years will double by 2030), it is important to assess the feasibility and tolerance of new irradiation techniques, notably the intensity-modulated radiotherapy, for elderly people, particularly in the case of pelvic tumours. Based on a sample of 18 patients, the authors notice that tomo-therapy reduces the digestive and urinary toxicity, and thus could be used for the treatment of aged patients, even 80 to 90 year old patients in good general status. However, these results need to be confirmed by a study on a larger scale. Short communication

  2. Feasibility study of multi-pass respiratory-gated helical tomotherapy of a moving target via binary MLC closure

    Science.gov (United States)

    Kim, Bryan; Chen, Jeff; Kron, Tomas; Battista, Jerry

    2010-11-01

    Gated radiotherapy of lung lesions is particularly complex for helical tomotherapy, due to the simultaneous motions of its three subsystems (gantry, couch and collimator). We propose a new way to implement gating for helical tomotherapy, namely multi-pass respiratory gating. In this method, gating is achieved by delivering only the beam projections that occur within a respiratory gating window, while blocking the rest of the beam projections by fully closing all collimator leaves. Due to the continuous couch motion, the planned beam projections must be delivered over multiple passes of radiation deliveries. After each pass, the patient couch is reset to its starting position, and the treatment recommences at a different phase of tumour motion to 'fill in' the previously blocked beam projections. The gating process may be repeated until the plan dose is delivered (full gating), or halted after a certain number of passes, with the entire remaining dose delivered in a final pass without gating (partial gating). The feasibility of the full gating approach was first tested for sinusoidal target motion, through experimental measurements with film and computer simulation. The optimal gating parameters for full and partial gating methods were then determined for various fractionation schemes through computer simulation, using a patient respiratory waveform. For sinusoidal motion, the PTV dose deviations of -29 to 5% observed without gating were reduced to range from -1 to 3% for a single fraction, with a 4 pass full gating. For a patient waveform, partial gating required fewer passes than full gating for all fractionation schemes. For a single fraction, the maximum allowed residual motion was only 4 mm, requiring large numbers of passes for both full (12) and partial (7 + 1) gating methods. The number of required passes decreased significantly for 3 and 30 fractions, allowing residual motion up to 7 mm. Overall, the multi-pass gating technique was shown to be a promising

  3. Feasibility study of multi-pass respiratory-gated helical tomotherapy of a moving target via binary MLC closure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bryan; Chen, Jeff; Battista, Jerry [London Regional Cancer Program, London Health Sciences Centre, London, ON (Canada); Kron, Tomas, E-mail: bryan.kim@lhsc.on.c [Peter MacCallum Cancer Center, Melbourne (Australia)

    2010-11-21

    Gated radiotherapy of lung lesions is particularly complex for helical tomotherapy, due to the simultaneous motions of its three subsystems (gantry, couch and collimator). We propose a new way to implement gating for helical tomotherapy, namely multi-pass respiratory gating. In this method, gating is achieved by delivering only the beam projections that occur within a respiratory gating window, while blocking the rest of the beam projections by fully closing all collimator leaves. Due to the continuous couch motion, the planned beam projections must be delivered over multiple passes of radiation deliveries. After each pass, the patient couch is reset to its starting position, and the treatment recommences at a different phase of tumour motion to 'fill in' the previously blocked beam projections. The gating process may be repeated until the plan dose is delivered (full gating), or halted after a certain number of passes, with the entire remaining dose delivered in a final pass without gating (partial gating). The feasibility of the full gating approach was first tested for sinusoidal target motion, through experimental measurements with film and computer simulation. The optimal gating parameters for full and partial gating methods were then determined for various fractionation schemes through computer simulation, using a patient respiratory waveform. For sinusoidal motion, the PTV dose deviations of -29 to 5% observed without gating were reduced to range from -1 to 3% for a single fraction, with a 4 pass full gating. For a patient waveform, partial gating required fewer passes than full gating for all fractionation schemes. For a single fraction, the maximum allowed residual motion was only 4 mm, requiring large numbers of passes for both full (12) and partial (7 + 1) gating methods. The number of required passes decreased significantly for 3 and 30 fractions, allowing residual motion up to 7 mm. Overall, the multi-pass gating technique was shown to be a

  4. An assessment of the use of skin flashes in helical tomotherapy using phantom and in-vivo dosimetry

    International Nuclear Information System (INIS)

    Tournel, Koen; Verellen, Dirk; Duchateau, Michael; Fierens, Yves; Linthout, Nadine; Reynders, Truus; Voordeckers, Mia; Storme, Guy

    2007-01-01

    Background and purpose: In helical tomotherapy the nature of the optimizing and planning systems allows the delivery of dose on the skin using a build-up compensating technique (skin flash). However, positioning errors or changes in the patient's contour can influence the correct dosage in these regions. This work studies the behavior of skin-flash regions using phantom and in-vivo dosimetry. Materials and methods: The dosimetric accuracy of the tomotherapy planning system in skin-flash regions is checked using film and TLD on phantom. Positioning errors are induced and the effect on the skin dose is investigated. Further a volume decrease is simulated using bolus material and the results are compared. Results: Results show that the tomotherapy planning system calculates dose on skin regions within 2 SD using TLD measurements. Film measurements show drops of dose of 2.8% and 26% for, respectively, a 5 mm and 10 mm mispositioning of the phantom towards air and a dose increase of 9% for a 5 mm shift towards tissue. These measurements are confirmed by TLD measurements. A simulated volume reduction shows a similar behavior with a 2.6% and 19.4% drop in dose, measured with TLDs. Conclusion: The tomotherapy system allows adequate planning and delivery of dose using skin flashes. However, exact positioning is crucial to deliver the dose at the exact location

  5. Clinical benefits of new immobilization system for hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma by helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yong; Zhou, Yong-Kang; Chen, Yi-Xing; Shi, Shi-Ming; Zeng, Zhao-Chong, E-mail: zeng.zhaochong@zs-hospital.sh.cn

    2017-04-01

    Objective: A comprehensive clinical evaluation was conducted, assessing the Body Pro-Lok immobilization and positioning system to facilitate hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma (HCC), using helical tomotherapy to improve treatment precision. Methods: Clinical applications of the Body Pro-Lok system were investigated (as above) in terms of interfractional and intrafractional setup errors and compressive abdominal breath control. To assess interfractional setup errors, a total of 42 patients who were given 5 to 20 fractions of helical tomotherapy for intrahepatic HCC were analyzed. Overall, 15 patients were immobilized using simple vacuum cushion (group A), and the Body Pro-Lok system was used in 27 patients (group B), performing megavoltage computed tomography (MVCT) scans 196 times and 435 times, respectively. Pretreatment MVCT scans were registered to the planning kilovoltage computed tomography (KVCT) for error determination, and group comparisons were made. To establish intrafractional setup errors, 17 patients with intrahepatic HCC were selected at random for immobilization by Body Pro-Lok system, undergoing MVCT scans after helical tomotherapy every week. A total of 46 MVCT re-scans were analyzed for this purpose. In researching breath control, 12 patients, randomly selected, were immobilized by Body Pro-Lok system and subjected to 2-phase 4-dimensional CT (4DCT) scans, with compressive abdominal control or in freely breathing states, respectively. Respiratory-induced liver motion was then compared. Results: Mean interfractional setup errors were as follows: (1) group A: X, 2.97 ± 2.47 mm; Y, 4.85 ± 4.04 mm; and Z, 3.77 ± 3.21 mm; pitch, 0.66 ± 0.62°; roll, 1.09 ± 1.06°; and yaw, 0.85 ± 0.82°; and (2) group B: X, 2.23 ± 1.79 mm; Y, 4.10 ± 3.36 mm; and Z, 1.67 ± 1.91 mm; pitch, 0.45 ± 0.38°; roll, 0.77 ± 0.63°; and yaw, 0.52 ± 0.49°. Between-group differences were statistically significant in 6 directions (p

  6. Clinical benefits of new immobilization system for hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma by helical tomotherapy

    International Nuclear Information System (INIS)

    Hu, Yong; Zhou, Yong-Kang; Chen, Yi-Xing; Shi, Shi-Ming; Zeng, Zhao-Chong

    2017-01-01

    Objective: A comprehensive clinical evaluation was conducted, assessing the Body Pro-Lok immobilization and positioning system to facilitate hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma (HCC), using helical tomotherapy to improve treatment precision. Methods: Clinical applications of the Body Pro-Lok system were investigated (as above) in terms of interfractional and intrafractional setup errors and compressive abdominal breath control. To assess interfractional setup errors, a total of 42 patients who were given 5 to 20 fractions of helical tomotherapy for intrahepatic HCC were analyzed. Overall, 15 patients were immobilized using simple vacuum cushion (group A), and the Body Pro-Lok system was used in 27 patients (group B), performing megavoltage computed tomography (MVCT) scans 196 times and 435 times, respectively. Pretreatment MVCT scans were registered to the planning kilovoltage computed tomography (KVCT) for error determination, and group comparisons were made. To establish intrafractional setup errors, 17 patients with intrahepatic HCC were selected at random for immobilization by Body Pro-Lok system, undergoing MVCT scans after helical tomotherapy every week. A total of 46 MVCT re-scans were analyzed for this purpose. In researching breath control, 12 patients, randomly selected, were immobilized by Body Pro-Lok system and subjected to 2-phase 4-dimensional CT (4DCT) scans, with compressive abdominal control or in freely breathing states, respectively. Respiratory-induced liver motion was then compared. Results: Mean interfractional setup errors were as follows: (1) group A: X, 2.97 ± 2.47 mm; Y, 4.85 ± 4.04 mm; and Z, 3.77 ± 3.21 mm; pitch, 0.66 ± 0.62°; roll, 1.09 ± 1.06°; and yaw, 0.85 ± 0.82°; and (2) group B: X, 2.23 ± 1.79 mm; Y, 4.10 ± 3.36 mm; and Z, 1.67 ± 1.91 mm; pitch, 0.45 ± 0.38°; roll, 0.77 ± 0.63°; and yaw, 0.52 ± 0.49°. Between-group differences were statistically significant in 6 directions (p

  7. Phase II Study of Preoperative Helical Tomotherapy With a Simultaneous Integrated Boost for Rectal Cancer

    International Nuclear Information System (INIS)

    Engels, Benedikt; Tournel, Koen; Everaert, Hendrik; Hoorens, Anne; Sermeus, Alexandra; Christian, Nicolas; Storme, Guy; Verellen, Dirk; De Ridder, Mark

    2012-01-01

    Purpose: The addition of concomitant chemotherapy to preoperative radiotherapy is considered the standard of care for patients with cT3–4 rectal cancer. The combined treatment modality increases the complete response rate and local control (LC), but has no impact on survival or the incidence of distant metastases. In addition, it is associated with considerable toxicity. As an alternative strategy, we explored prospectively, preoperative helical tomotherapy with a simultaneous integrated boost (SIB). Methods and Materials: A total of 108 patients were treated with intensity-modulated and image-guided radiotherapy using the Tomotherapy Hi-Art II system. A dose of 46 Gy, in daily fractions of 2 Gy, was delivered to the mesorectum and draining lymph nodes, without concomitant chemotherapy. Patients with an anticipated circumferential resection margin (CRM) of less than 2 mm, based on magnetic resonance imaging, received a SIB to the tumor up to a total dose of 55.2 Gy. Acute and late side effects were scored using the National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0. Results: A total of 102 patients presented with cT3–4 tumors; 57 patients entered the boost group and 51 the no-boost group. One patient in the no-boost group developed a radio-hypersensitivity reaction, resulting in a complete tumor remission, a Grade 3 acute and Grade 5 late enteritis. No other Grade ≥3 acute toxicities occurred. With a median follow-up of 32 months, Grade ≥3 late gastrointestinal and urinary toxicity were observed in 6% and 4% of the patients, respectively. The actuarial 2-year LC, progression-free survival and overall survival were 98%, 79%, and 93%. Conclusions: Preoperative helical tomotherapy displays a favorable acute toxicity profile in patients with cT3–4 rectal cancer. A SIB can be safely administered in patients with a narrow CRM and resulted in a promising LC.

  8. Investigation of Pitch and Jaw Width to Decrease Delivery Time of Helical Tomotherapy Treatments for Head and Neck Cancer

    International Nuclear Information System (INIS)

    Moldovan, Monica; Fontenot, Jonas D.; Gibbons, John P.; Lee, Tae Kyu; Rosen, Isaac I.; Fields, Robert S.; Hogstrom, Kenneth R.

    2011-01-01

    Helical tomotherapy plans using a combination of pitch and jaw width settings were developed for 3 patients previously treated for head and neck cancer. Three jaw widths (5, 2.5, and 1 cm) and 4 pitches (0.86, 0.43, 0.287, and 0.215) were used with a (maximum) modulation factor setting of 4. Twelve plans were generated for each patient using an identical optimization procedure (e.g., number of iterations, objective weights, and penalties, etc.), based on recommendations from TomoTherapy (Madison, WI). The plans were compared using isodose plots, dose volume histograms, dose homogeneity indexes, conformity indexes, radiobiological models, and treatment times. Smaller pitches and jaw widths showed better target dose homogeneity and sparing of normal tissue, as expected. However, the treatment time increased inversely proportional to the jaw width, resulting in delivery times of 24 ± 1.9 min for the 1-cm jaw width. Although treatment plans produced with the 2.5-cm jaw were dosimetrically superior to plans produced with the 5-cm jaw, subsequent calculations of tumor control probabilities and normal tissue complication probabilities suggest that these differences may not be radiobiologically meaningful. Because treatment plans produced with the 5-cm jaw can be delivered in approximately half the time of plans produced with the 2.5-cm jaw (5.1 ± 0.6 min vs. 9.5 ± 1.1 min), use of the 5-cm jaw in routine treatment planning may be a viable approach to decreasing treatment delivery times from helical tomotherapy units.

  9. Dose-escalated simultaneous integrated-boost treatment of prostate cancer patients via helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Geier, M.; Astner, S.T.; Duma, M.N.; Putzhammer, J.; Winkler, C.; Molls, M.; Geinitz, H. [Technische Univ. Muenchen (Germany). Klinik und Poliklinik fuer Strahlentherapie und Radiologische Onkologie; Jacob, V. [Universitaetsklinikum Freiburg (Germany). Klinik fuer Strahlenheilkunde; Nieder, C. [Nordland Hospital, Bodoe (Norway). Dept. of Oncology and Palliative Care; Tromsoe Univ. (Norway). Inst. of Clinical Medicine

    2012-05-15

    The goal of this work was to assess the feasibility of moderately hypofractionated simultaneous integrated-boost intensity-modulated radiotherapy (SIB-IMRT) with helical tomotherapy in patients with localized prostate cancer regarding acute side effects and dose-volume histogram data (DVH data). Acute side effects and DVH data were evaluated of the first 40 intermediate risk prostate cancer patients treated with a definitive daily image-guided SIB-IMRT protocol via helical tomotherapy in our department. The planning target volume including the prostate and the base of the seminal vesicles with safety margins was treated with 70 Gy in 35 fractions. The boost volume containing the prostate and 3 mm safety margins (5 mm craniocaudal) was treated as SIB to a total dose of 76 Gy (2.17 Gy per fraction). Planning constraints for the anterior rectal wall were set in order not to exceed the dose of 76 Gy prescribed to the boost volume. Acute toxicity was evaluated prospectively using a modified CTCAE (Common Terminology Criteria for Adverse Events) score. SIB-IMRT allowed good rectal sparing, although the full boost dose was permitted to the anterior rectal wall. Median rectum dose was 38 Gy in all patients and the median volumes receiving at least 65 Gy (V65), 70 Gy (V70), and 75 Gy (V75) were 13.5%, 9%, and 3%, respectively. No grade 4 toxicity was observed. Acute grade 3 toxicity was observed in 20% of patients involving nocturia only. Grade 2 acute intestinal and urological side effects occurred in 25% and 57.5%, respectively. No correlation was found between acute toxicity and the DVH data. This institutional SIB-IMRT protocol using daily image guidance as a precondition for smaller safety margins allows dose escalation to the prostate without increasing acute toxicity. (orig.)

  10. Helical Tomotherapy Planning for Left-Sided Breast Cancer Patients With Positive Lymph Nodes: Comparison to Conventional Multiport Breast Technique

    International Nuclear Information System (INIS)

    Goddu, S. Murty; Chaudhari, Summer; Mamalui-Hunter, Maria; Pechenaya, Olga L.; Pratt, David; Mutic, Sasa; Zoberi, Imran; Jeswani, Sam; Powell, Simon N.; Low, Daniel A.

    2009-01-01

    Purpose: To evaluate the feasibility of using helical tomotherapy for locally advanced left-sided breast cancer. Methods and Materials: Treatment plans were generated for 10 left-sided breast cancer patients with positive lymph nodes comparing a multiport breast (three-dimensional) technique with the tomotherapy treatment planning system. The planning target volumes, including the chest wall/breast, supraclavicular, axillary, and internal mammary lymph nodes, were contoured. The treatment plans were generated on the tomotherapy treatment planning system to deliver 50.4 Gy to the planning target volume. To spare the contralateral tissues, directional blocking was applied to the right breast and right lung. The optimization goals were to protect the lungs, heart, and right breast. Results: The tomotherapy plans increased the minimal dose to the planning target volume (minimal dose received by 99% of target volume = 46.2 ± 1.3 Gy vs. 27.9 ± 17.1 Gy) while improving the dose homogeneity (dose difference between the minimal dose received by 5% and 95% of the planning target volume = 7.5 ± 1.8 Gy vs. 37.5 ± 26.9 Gy). The mean percentage of the left lung volume receiving ≥20 Gy in the tomotherapy plans decreased from 32.6% ± 4.1% to 17.6% ± 3.5%, while restricting the right-lung mean dose to <5 Gy. However, the mean percentage of volume receiving ≥5 Gy for the total lung increased from 25.2% ± 4.2% for the three-dimensional technique to 46.9% ± 8.4% for the tomotherapy plan. The mean volume receiving ≥35 Gy for the heart decreased from 5.6% ± 4.8% to 2.2% ± 1.5% in the tomotherapy plans. However, the mean heart dose for tomotherapy delivery increased from 7.5 ± 3.4 Gy to 12.2 ± 1.8 Gy. Conclusion: The tomotherapy plans provided better dose conformity and homogeneity than did the three-dimensional plans for treatment of left-sided breast tumors with regional lymph node involvement, while allowing greater sparing of the heart and left lung from doses

  11. Whole brain helical Tomotherapy with integrated boost for brain metastases in patients with malignant melanoma–a randomized trial

    International Nuclear Information System (INIS)

    Hauswald, Henrik; Habl, Gregor; Krug, David; Kehle, Denise; Combs, Stephanie E; Bermejo, Justo Lorenzo; Debus, Jürgen; Sterzing, Florian

    2013-01-01

    Patients with malignant melanoma may develop brain metastases during the course of the disease, requiring radiotherapeutic treatment. In patients with 1–3 brain metastases, radiosurgery has been established as a treatment option besides surgery. For patients with 4 or more brain metastases, whole brain radiotherapy is considered the standard treatment. In certain patients with brain metastases, radiation treatment using whole brain helical Tomotherapy with integrated boost and hippocampal-sparing may improve prognosis of these patients. The present prospective, randomized two-armed trial aims to exploratory investigate the treatment response to conventional whole brain radiotherapy applying 30 Gy in 10 fractions versus whole brain helical Tomotherapy applying 30 Gy in 10 fractions with an integrated boost of 50 Gy to the brain metastases as well as hippocampal-sparing in patients with brain metastases from malignant melanoma. The main inclusion criteria include magnetic resonance imaging confirmed brain metastases from a histopathologically confirmed malignant melanoma in patients with a minimum age of 18 years. The main exclusion criteria include a previous radiotherapy of the brain and not having recovered from acute high-grade toxicities of prior therapies. The primary endpoint is treatment-related toxicity. Secondary endpoints include imaging response, local and loco-regional progression-free survival, overall survival and quality of life

  12. Multi-centre experience of implementing image-guided intensity-modulated radiotherapy using the TomoTherapy platform

    International Nuclear Information System (INIS)

    Dean, J.C.; Tudor, G.S.J.; Mott, J.H.; Dunlop, P.R.; Morris, S.L.; Harron, E.C.; Christian, J.A.; Sanghera, P.; Elsworthy, M.; Burnet, N.G.

    2013-01-01

    Use of image guided (IG) intensity modulated radiotherapy (IMRT) is increasing, and helical tomotherapy provides an effective, integrated solution. Practical experience of implementation, shared at a recent UK TomoTherapy Users' meeting, may help centres introducing these techniques using TomoTherapy or other platforms. Seven centres participated, with data shared from 6, varying from 2500 - 4800 new patients per year. Case selection of patients “most likely” to benefit from IG-IMRT was managed in all centres by multi-professional groups comprising clinical oncologists, physicists, treatment planners and radiographers. Radical treatments ranged from 94% to 100%. The proportions of tumour types varied substantially: head and neck: range 0%–100% (mean of centres 50%), prostate: 3%–96% (mean of centres 28%). Head and neck cases were considered most likely to benefit from IMRT, prostate cases from IGRT, or IG-IMRT if pelvic nodes were being treated. IMRT was also selected for complex target volumes, to avoid field junctions, for technical treatment difficulties, and retreatments. Across the centres, every patient was imaged every day, with positional correction before treatment. In one centre, for prostate patients including pelvic treatment, the pelvis was also imaged weekly. All centres had designed a ‘ramp up’ of patient numbers, which was similar in 5. One centre, treating 96% prostate patients, started with 3 and increased to 36 patients per day within 3 months. The variation in case mix implies wide applicability of IG-IMRT. Daily on-line IGRT with IMRT can be routinely implemented into busy departments

  13. Development of a software tool for the management of quality control in a helical tomotherapy unit

    International Nuclear Information System (INIS)

    Garcia Repiso, S.; Hernandez Rodriguez, J.; Martin Rincon, C.; Ramos Pacho, J. A.; Verde Velasco, J. M.; Delgado Aparacio, J. M.; Perez Alvarez, M. e.; Gomez Gonzalez, N.; Cons Perez, V.; Saez Beltran, M.

    2013-01-01

    The large amount of data and information that is managed in units of external radiotherapy quality control tests makes necessary the use of tools that facilitate, on the one hand, the management of measures and results in real time, and on other tasks of management, file, query and reporting of stored data. This paper presents an application of software of own development which is used for the integral management of the helical TomoTherapy unit in the aspects related to the roles and responsibilities of the hospital Radiophysics. (Author)

  14. The helical tomo-therapy: appeal to projects Inca 2005 first assessment of the three equipped establishments

    International Nuclear Information System (INIS)

    Zefkili, S.; Francois, P.; Giraud, P.; Caron, J.; Dejean, C.; Kantor, G.; Munos, C.; Mahe, M.A.; Lisbona, A.

    2007-01-01

    The centers of fight against cancer ( C.L.C.C.) Institute Curie of Paris, Institute Bergonie of Bordeaux, Center Rene Gauducheau of Nantes have got to exploit the helical radiotherapy (tomo-therapy) in the frame of an appeal to projects launched in 2005 by the National Institute of cancer (I.n.c.a.) in relation with the innovating techniques in radiotherapy and presenting one of the measures of the Cancer plan 2003-2007. This communication constitutes a step report in the installation and use of equipments. (N.C.)

  15. Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy

    International Nuclear Information System (INIS)

    Rong Yi; Yadav, Poonam; Welsh, James S.; Fahner, Tasha; Paliwal, Bhudatt

    2012-01-01

    The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3–50.4 Gy with daily fraction size of 1.7–2.0 Gy. Total dose to the scar PTV was prescribed to 58.0–60.2 Gy at 2.0–2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTV received 1.7–1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments.

  16. Helical tomotherapy for extramedullary hematopoiesis involving the pericardium in a patient with chronic myeloid leukemia.

    Science.gov (United States)

    Toms, Daniel R; Cannick, Leander; Stuart, Robert K; Jenrette, Joseph M; Terwiliger, Lacy

    2010-07-01

    Extramedullary hematopoiesis (EMH) refers to the development of foci of hematopoiesis outside its normal location in the bone marrow. This occurs normally during fetal development but is abnormal postpartum. The most common sites of EMH are the spleen and liver. The phenomenon occurs in a number of disease states, notably in myelofibrosis, thalassemia, immune thrombocytopenic purpura, sickle cell anemia, polycythemia vera, and myelodysplastic syndrome. Affected patients often develop symptoms related to the location of the EMH. Reported treatments include red blood cell transfusions, surgical excision, decompressive laminectomy in cases of cord compression, chemotherapy, and irradiation. Radiation therapy is highly effective for treating hematopoietic tissue because such tissues are extremely radiosensitive. Megavoltage helical tomotherapy is a technical advance in the delivery of radiation therapy, allowing more conformal and precise treatments. The present case report describes a patient with the diagnosis of atypical chronic myeloid leukemia and myelofibrosis who subsequently developed EMH of the pericardium with effusion and tamponade. By utilizing tomotherapy we were able to treat the pericardium while sparing much of the myocardium. The patient tolerated treatment well without acute adverse effects. His symptoms were alleviated, but he died approximately 1 year later.

  17. Effect of CT contrast on volumetric arc therapy planning (RapidArc and helical tomotherapy) for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Alan J.; Vora, Nayana [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States); Suh, Steve [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Liu, An, E-mail: aliu@coh.org [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Schultheiss, Timothy E. [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Wong, Jeffrey Y.C. [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States)

    2015-04-01

    The objectives of the study were to evaluate the effect of intravenous contrast in the dosimetry of helical tomotherapy and RapidArc treatment for head and neck cancer and determine if it is acceptable during the computed tomography (CT) simulation to acquire only CT with contrast for treatment planning of head and neck cancer. Overall, 5 patients with head and neck cancer (4 men and 1 woman) treated on helical tomotherapy were analyzed retrospectively. For each patient, 2 consecutive CT scans were performed. The first CT set was scanned before the contrast injection and secondary study set was scanned 45 seconds after contrast. The 2 CTs were autoregistered using the same Digital Imaging and Communications in Medicine coordinates. Tomotherapy and RapidArc plans were generated on 1 CT data set and subsequently copied to the second CT set. Dose calculation was performed, and dose difference was analyzed to evaluate the influence of intravenous contrast media. The dose matrix used for comparison included mean, minimum and maximum doses of planning target volume (PTV), PTV dose coverage, and V{sub 45} {sub Gy}, V{sub 30} {sub Gy}, and V{sub 20} {sub Gy} organ doses. Treatment planning on contrasted images generally showed a lower dose to both organs and target than plans on noncontrasted images. The doses for the points of interest placed in the organs and target rarely changed more than 2% in any patient. In conclusion, treatment planning using a contrasted image had insignificant effect on the dose to the organs and targets. In our opinion, only CT with contrast needs to be acquired during the CT simulation for head and neck cancer. Dose calculations performed on contrasted images can potentially underestimate the delivery dose slightly. However, the errors of planning on a contrasted image should not affect the result in clinically significant way.

  18. Pelvic tomo-therapy among 70 to 90 year old patients: feasibility and tolerance; Tomotherapie pelvienne chez les sujets ages de 70 a 90 ans: faisabilite et tolerance

    Energy Technology Data Exchange (ETDEWEB)

    Bibault, J.E.; Nickers, P.; Castelain, B.; Lacornerie, T.; Reynaert, N.; Lartigau, E. [Centre Oscar-Lambret, 59 - Lille (France)

    2010-10-15

    As population is getting older (the number of people older than 70 years will double by 2030), it is important to assess the feasibility and tolerance of new irradiation techniques, notably the intensity-modulated radiotherapy, for elderly people, particularly in the case of pelvic tumours. Based on a sample of 18 patients, the authors notice that tomo-therapy reduces the digestive and urinary toxicity, and thus could be used for the treatment of aged patients, even 80 to 90 year old patients in good general status. However, these results need to be confirmed by a study on a larger scale. Short communication

  19. Comparing conformal, arc radiotherapy and helical tomotherapy in craniospinal irradiation planning.

    Science.gov (United States)

    Myers, Pamela A; Mavroidis, Panayiotis; Papanikolaou, Nikos; Stathakis, Sotirios

    2014-09-08

    Currently, radiotherapy treatment plan acceptance is based primarily on dosimetric performance measures. However, use of radiobiological analysis to assess benefit in terms of tumor control and harm in terms of injury to normal tissues can be advantageous. For pediatric craniospinal axis irradiation (CSI) patients, in particular, knowing the technique that will optimize the probabilities of benefit versus injury can lead to better long-term outcomes. Twenty-four CSI pediatric patients (median age 10) were retrospectively planned with three techniques: three-dimensional conformal radiation therapy (3D CRT), volumetric-modulated arc therapy (VMAT), and helical tomotherapy (HT). VMAT plans consisted of one superior and one inferior full arc, and tomotherapy plans were created using a 5.02cm field width and helical pitch of 0.287. Each plan was normalized to 95% of target volume (whole brain and spinal cord) receiving prescription dose 23.4Gy in 13 fractions. Using an in-house MATLAB code and DVH data from each plan, the three techniques were evaluated based on biologically effective uniform dose (D=), the complication-free tumor control probability (P+), and the width of the therapeutically beneficial range. Overall, 3D CRT and VMAT plans had similar values of D= (24.1 and 24.2 Gy), while HT had a D= slightly lower (23.6 Gy). The average values of the P+ index were 64.6, 67.4, and 56.6% for 3D CRT, VMAT, and HT plans, respectively, with the VMAT plans having a statistically significant increase in P+. Optimal values of D= were 28.4, 33.0, and 31.9 Gy for 3D CRT, VMAT, and HT plans, respectively. Although P+ values that correspond to the initial dose prescription were lower for HT, after optimizing the D= prescription level, the optimal P+ became 94.1, 99.5, and 99.6% for 3D CRT, VMAT, and HT, respectively, with the VMAT and HT plans having statistically significant increases in P+. If the optimal dose level is prescribed using a radiobiological evaluation method, as

  20. Intensity-modulated radiation therapy using static ports of tomotherapy (TomoDirect): comparison with the TomoHelical mode

    International Nuclear Information System (INIS)

    Murai, Taro; Shibamoto, Yuta; Manabe, Yoshihiko; Murata, Rumi; Sugie, Chikao; Hayashi, Akihiro; Ito, Hiroya; Miyoshi, Yoshihito

    2013-01-01

    With the new mode of Tomotherapy, irradiation can be delivered using static ports of the TomoDirect mode. The purpose of this study was to evaluate the characteristics of TomoDirect plans compared to conventional TomoHelical plans. TomoDirect and TomoHelical plans were compared in 46 patients with a prostate, thoracic wall or lung tumor. The mean target dose was used as the prescription dose. The minimum coverage dose of 95% of the target (D95%), conformity index (CI), uniformity index (UI), dose distribution in organs at risk and treatment time were evaluated. For TomoDirect, 2 to 5 static ports were used depending on the tumor location. For the prostate target volume, TomoDirect plans could not reduce the rectal dose and required a longer treatment time than TomoHelical. For the thoracic wall target volume, the V5Gy of the lung or liver was lower in TomoDirect than in TomoHelical (p = 0.02). For the lung target volume, TomoDirect yielded higher CI (p = 0.009) but smaller V5Gy of the lung (p = 0.005) than TomoHelical. Treatment time did not differ significantly between the thoracic wall and lung plans. Prostate cancers should be treated with the TomoHelical mode. Considering the risk of low-dose radiation to the lung, the TomoDirect mode could be an option for thoracic wall and lung tumors

  1. The using of megavoltage computed tomography in image-guided brachytherapy for cervical cancer: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Tharavichitkul, Ekkasit; Janla-or, Suwapim; Wanwilairat, Somsak; Chakrabandhu, Somvilai; Klunklin, Pitchayaponne; Onchan, Wimrak; Supawongwattana, Bongkot; Chitapanarux, Imjai [Division of Therapeutic Radiology and Oncology, Dept. of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai (Thailand); Galalae, Razvan M. [Faculty of Medicine, Christian-Albrecht University (Campus Kiel), Kiel (Germany)

    2015-06-15

    We present a case of cervical cancer treated by concurrent chemoradiation. In radiation therapy part, the combination of the whole pelvic helical tomotherapy plus image-guided brachytherapy with megavoltage computed tomography of helical tomotherapy was performed. We propose this therapeutic approach could be considered in a curative setting in some problematic situation as our institution.

  2. Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

    International Nuclear Information System (INIS)

    Staton, Robert J.; Langen, Katja M.; Kupelian, Patrick A.; Meeks, Sanford L.

    2009-01-01

    In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about ±2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude (±2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of ±7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D 50 of organs at risk, the D 95 for planning target volumes (PTVs), and the local dose difference were used to

  3. SU-F-BRB-13: Correlation of Improved Target and Organ-At-Risk Dosimetric Quantities and Clinical Outcomes for Helical Tomotherapy Treated Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Qi, S; Kishan, A; Alexander, S; Lee, P; Selch, M; Kupelian, P; Steiberg, M; Low, D [UCLA, Los Angeles, CA (United States)

    2015-06-15

    Purpose: We have observed improved local control probability (LCP) for adjuvant mesothelioma radiotherapy following pleurectomy/decortication using Tomotherapy compared to the conventional 3D technique (p<0.05). This work assesses the correlation between the improved clinical outcomes against dosimetry quantities. Methods: Thirty-eight mesothelioma cases consecutively treated at our clinic were retrospectively analyzed. Sixteen patients were treated using 3D technique planned on the Eclipse for c-arm accelerators prior to 7/2012; the other 22 cases were treated on Tomotherapy using helical IMRT after 7/2012. Typical 3D plans consisting of 15 MV AP/PA photon fields prescribed to 10 cm depth followed by matching electron fields with energy ranging from 8–16 MeV. Tomotherapy plans were designed using 2.5cm jaw, 0.287 pitch with directional blocking of the contralateral lung. The same prescription of 45 Gy (1.8GyX25) was used for both techniques. The dosimetry metrics for the critical structures: ipsilateral-/contralateral-lung, heart, cord, esophagus, etc were compared between two techniques. Results: Superior LCP is closely associated with improved target coverage. Tomotherapy plans yielded dramatically better target coverage and less dose heterogeneity despite of more advanced/larger disease. The averaged PTV volumes were 2287.3±569.9 (Tomotherapy) vs. 1904.8±312.3cc (3D); V100s were: 91.1±4.0 (%) vs. 47.8±12.7 (%) with heterogeneity indices of 1.20±0.1 vs.1.37±0.38 and for the Tomotherapy and 3D plans, respectively. Compared to the 3D technique, we observed significant lower maximum cord doses (p<0.001), lower mean esophagus doses (p<0.002), and lower heart mean doses when tumor was left-sided (p=0.002). For ipsilateral-/contralateral-lungs, however, the mean doses and V20, V5 of Tomotherapy plans were significantly higher than the 3D plans (p<0.01) regardless which sides of lung were treated. However, rates of radiation pneumonitis were no different

  4. Conventional patient specific IMRT QA and 3DVH verification of dose distribution for helical tomotherapy

    International Nuclear Information System (INIS)

    Sharma, Prabhat Krishna; Joshi, Kishore; Epili, D.; Gavake, Umesh; Paul, Siji; Reena, Ph.; Jamema, S.V.

    2016-01-01

    In recent years, patient-specific IMRT QA has transitioned from point dose measurements by ion chambers to films to 2D array measurements. 3DVH software has taken this transition a step further by estimating the 3D dose delivered to the patient volume from 2D diode measurements using a planned dose perturbation (PDP) algorithm. This algorithm was developed to determine, if the conventional IMRT QA though sensitive at detecting errors, has any predictive power in detecting dose errors of clinical significance related to dose to the target volume and organs at risk (OAR). The aim of this study is to compare the conventional IMRT patient specific QA and 3DVH dose distribution for patients treated with helical tomotherapy (HT)

  5. Dosimetric comparison between helical tomotherapy and volumetric modulated arc-therapy for non-anaplastic thyroid cancer treatment.

    Science.gov (United States)

    Khalifa, Jonathan; Vieillevigne, Laure; Boyrie, Sabrina; Ouali, Monia; Filleron, Thomas; Rives, Michel; Laprie, Anne

    2014-11-26

    To evaluate and compare dosimetric parameters of volumetric modulated arctherapy (VMAT) and helical tomotherapy (HT) for non-anaplastic thyroid cancer adjuvant radiotherapy. Twelve patients with non-anaplastic thyroid cancer at high risk of local relapse received adjuvant external beam radiotherapy with curative intent in our institution, using a two-dose level prescription with a simultaneous integrated boost approach. Each patient was re-planned by the same physicist twice using both VMAT and HT. Several dosimetric quality indexes were used: target coverage index (proportion of the target volume covered by the reference isodose), healthy tissue conformity index (proportion of the reference isodose volume including the target volume), conformation number (combining both previous indexes), Dice Similarity Coefficient (DSC), and homogeneity index ((D2%-D98%)/prescribed dose). Dose-volume histogram statistics were also compared. HT provided statistically better target coverage index and homogeneity index for low risk PTV in comparison with VMAT (respectively 0.99 vs. 0.97 (p=0.008) and 0.22 vs. 0.25 (p=0.016)). However, HT provided poorer results for healthy tissue conformity index, conformation number and DSC with low risk and high risk PTV. As regards organs at risk sparing, by comparison with VMAT, HT statistically decreased the D2% to medullary canal (25.3 Gy vs. 32.6 Gy (p=0.003)). Besides, HT allowed a slight sparing dose for the controlateral parotid (Dmean: 4.3 Gy vs. 6.6 Gy (p=0.032)) and for the controlateral sub-maxillary gland (Dmean: 29.1 Gy vs. 33.1 Gy (p=0.041)). Both VMAT and HT techniques for adjuvant treatment of non-anaplastic thyroid cancer provide globally attractive treatment plans with slight dosimetric differences. However, helical tomotherapy clearly provides a benefit in term of medullary canal sparing.

  6. Helical tomo-therapy in the anal canal cancer: dosimetric comparison with conformal radiotherapy with intensity modulation and classical conformal radiotherapy

    International Nuclear Information System (INIS)

    Ozsahin, M.; Ugurluer, G.; Ballerini, G.; Letenneur, G.; Zouhair, A.; Mirimanoff, R.O.

    2009-01-01

    A dosimetry comparison was made between helical tomo-therapy, I.M.R.T. and classical conformal three dimensional radiotherapy for twelve first patients that received a image guided radiotherapy, the toxicity was tackled with a minimum follow-up of fourteen months. In conclusion, the CT-guided radiotherapy allows to save organs at risks superior to I.M.R.T. and conformal radiotherapy and a best homogeneity in the target volume. the toxicity is moderated and the break time is limited. (N.C.)

  7. The use of a commercial QA device for daily output check of a helical tomotherapy unit

    International Nuclear Information System (INIS)

    Alaei, Parham; Hui, Susanta K.; Higgins, Patrick D.; Gerbi, Bruce J.

    2006-01-01

    Helical tomotherapy radiation therapy units, due to their particular design and differences from a traditional linear accelerator, require different procedures by which to perform routine quality assurance (QA). One of the principal QA tasks that should be performed daily on any radiation therapy equipment is the output constancy check. The daily output check on a Hi-Art TomoTherapy unit is commonly performed utilizing ionization chambers placed inside a solid water phantom. This provides a good check of output at one point, but does not give any information on either energy or symmetry of the beam, unless more than one point is measured. This also has the added disadvantage that it has to be done by the physics staff. To address these issues, and to simplify the process, such that it can be performed by radiation therapists, we investigated the use of a commercially available daily QA device to perform this task. The use of this device simplifies the task of daily output constancy checks and eliminates the need for continued physics involvement. This device can also be used to monitor the constancy of beam energy and cone profile and can potentially be used to detect gross errors in the couch movement or laser alignment

  8. Utility of Megavoltage Fan-Beam CT for Treatment Planning in a Head-And-Neck Cancer Patient with Extensive Dental Fillings Undergoing Helical Tomotherapy

    International Nuclear Information System (INIS)

    Yang, Claus; Liu Tianxiao; Jennelle, Richard L.; Ryu, Janice K.; Vijayakumar, Srinivasan; Purdy, James A.; Chen, Allen M.

    2010-01-01

    The purpose of this study was to demonstrate the potential utility of megavoltage fan-beam computed tomography (MV-FBCT) for treatment planning in a patient undergoing helical tomotherapy for nasopharyngeal carcinoma in the presence of extensive dental artifact. A 28-year-old female with locally advanced nasopharyngeal carcinoma presented for radiation therapy. Due to the extensiveness of the dental artifact present in the oral cavity kV-CT scan acquired at simulation, which made treatment planning impossible on tomotherapy planning system, MV-FBCT imaging was obtained using the HI-ART tomotherapy treatment machine, with the patient in the treatment position, and this information was registered with her original kV-CT scan for the purposes of structure delineation, dose calculation, and treatment planning. To validate the feasibility of the MV-FBCT-generated treatment plan, an electron density CT phantom (model 465, Gammex Inc., Middleton, WI) was scanned using MV-FBCT to obtain CT number to density table. Additionally, both a 'cheese' phantom (which came with the tomotherapy treatment machine) with 2 inserted ion chambers and a generic phantom called Quasar phantom (Modus Medical Devices Inc., London, ON, Canada) with one inserted chamber were used to confirm dosimetric accuracy. The MV-FBCT could be used to clearly visualize anatomy in the region of the dental artifact and provide sufficient soft-tissue contrast to assist in the delineation of normal tissue structures and fat planes. With the elimination of the dental artifact, the MV-FBCT images allowed more accurate dose calculation by the tomotherapy system. It was confirmed that the phantom material density was determined correctly by the tomotherapy MV-FBCT number to density table. The ion chamber measurements agreed with the calculations from the MV-FBCT generated phantom plan within 2%. MV-FBCT may be useful in radiation treatment planning for nasopharyngeal cancer patients in the setting of extensive

  9. Tomotherapy – a different way of dose delivery in radiotherapy

    Science.gov (United States)

    Skórska, Małgorzata; Jodda, Agata; Ryczkowski, Adam; Kaźmierska, Joanna; Adamska, Krystyna; Karczewska-Dzionk, Aldona; Żmijewska-Tomczak, Małgorzata; Włodarczyk, Hanna

    2012-01-01

    Aim of the study Helical tomotherapy is one of the methods of radiotherapy. This method enables treatment implementation for a wide spectrum of clinical cases. The vast array of therapeutic uses of helical tomotherapy results directly from the method of dose delivery, which is significantly different from the classic method developed for conventional linear accelerators. The paper discusses the method of dose delivery by a tomotherapy machine. Moreover, an analysis and presentation of treatment plans was performed in order to show the therapeutic possibilities of the applied technology. Dose distributions were obtained for anaplastic medulloblastoma, multifocal metastases to brain, vulva cancer, tongue cancer, metastases to bones, and advanced skin cancer. Tomotherapy treatment plans were compared with conventional linear accelerator plans. Results Following the comparative analysis of tomotherapy and conventional linear accelerator plans, in each case we obtained the increase in dose distribution conformity manifested in greater homogeneity of doses in the radiation target area for anaplastic medulloblastoma, multifocal metastases to brain, vulva cancer, metastases to bones, and advanced skin cancer, and the reduction of doses in organs at risk (OAR) for anaplastic medulloblastoma, vulva cancer, tongue cancer, and advanced skin cancer. The time of treatment delivery in the case of a tomotherapy machine is comparable to the implementation of the plan prepared in intensity-modulated radiotherapy (IMRT) technique for a conventional linear accelerator. In the case of tomotherapy the application of a fractional dose was carried out in each case during one working period of the machine. For a conventional linear accelerator the total value of the fractional dose in the case of anaplastic medulloblastoma and metastases to bones was delivered using several treatment plans, for which a change of set-up was necessary during a fraction. Conclusion The obtained results

  10. Dose-volume and biological-model based comparison between helical tomotherapy and (inverse-planned) IMAT for prostate tumours

    International Nuclear Information System (INIS)

    Iori, Mauro; Cattaneo, Giovanni Mauro; Cagni, Elisabetta; Fiorino, Claudio; Borasi, Gianni; Riccardo, Calandrino; Iotti, Cinzia; Fazio, Ferruccio; Nahum, Alan E.

    2008-01-01

    Background and purpose: Helical tomotherapy (HT) and intensity-modulated arc therapy (IMAT) are two arc-based approaches to the delivery of intensity-modulated radiotherapy (IMRT). Through plan comparisons we have investigated the potential of IMAT, both with constant (conventional or IMAT-C) and variable (non-conventional or IMAT-NC, a theoretical exercise) dose-rate, to serve as an alternative to helical tomotherapy. Materials and methods: Six patients with prostate tumours treated by HT with a moderately hypo-fractionated protocol, involving a simultaneous integrated boost, were re-planned as IMAT treatments. A method for IMAT inverse-planning using a commercial module for static IMRT combined with a multi-leaf collimator (MLC) arc-sequencing was developed. IMAT plans were compared to HT plans in terms of dose statistics and radiobiological indices. Results: Concerning the planning target volume (PTV), the mean doses for all PTVs were similar for HT and IMAT-C plans with minimum dose, target coverage, equivalent uniform dose (EUD) and tumour control probability (TCP) values being generally higher for HT; maximum dose and degree of heterogeneity were instead higher for IMAT-C. In relation to organs at risk, mean doses and normal tissue complication probability (NTCP) values were similar between the two modalities, except for the penile bulb where IMAT was significantly better. Re-normalizing all plans to the same rectal toxicity (NTCP = 5%), the HT modality yielded higher TCP than IMAT-C but there was no significant difference between HT and IMAT-NC. The integral dose with HT was higher than that for IMAT. Conclusions: with regards to the plan analysis, the HT is superior to IMAT-C in terms of target coverage and dose homogeneity within the PTV. Introducing dose-rate variation during arc-rotation, not deliverable with current linac technology, the simulations result in comparable plan indices between (IMAT-NC) and HT

  11. Sparing of the hippocampus and limbic circuit during whole brain radiation therapy: a dosimetric study using helical tomotherapy

    International Nuclear Information System (INIS)

    Marsh, J.C.; Gielda, B.T.; Herskovic, A.M.; Turian, J.V.

    2010-01-01

    Full text: The study aims to assess the feasibility of dosimetrically sparing the limbic circuit during whole brain radiation therapy (WBRT) and prophylactic cranial irradiation (PCI). Methods and Materials: We contoured the brain/brainstem on fused MRI and CT as the target volume (PTV) in 11 patients, excluding the hippocampus and the rest of the limbic circuit, which were considered organs at risk (OARs). PCI and WBRT helical tomotherapy plans were prepared for each patient with a 1.0-cm field width, pitch 0.285, initial modulation factor = 2.5. We attempted to spare the hippocampus and the rest of the limbic circuit while treating the rest of the brain to 30 Gy in 15 fractions (PCI) or 35 Gy in 14 fractions (WBRT) with VlOO ∼ 95%. The quality of the plans was assessed by calculating mean dose and equivalent uniform dose (EUD) for OARs and the % volume of the PTV receiving the prescribed dose, V 100. Results: In the PCI plans, mean doses/EUD were: hippocampus 12.5 Gy/ 14.23 Gy, rest of limbic circuit 17.0 Gy/19.02 Gy. In the WBRT plans, mean doses/EUD were: hippocampus 14.3 Gy/16.07 Gy, rest of limbic circuit 17.9 Gy/20.74 Gy. The mean VlOO for the rest of the brain (PTV) were 94.7% (PCl) and 95.1 % (WBRT). Mean PCI and WBRT treatment times were essentially identical (mean 15.23 min, range 14.27-17.5). Conclusions: It is dosimetrically feasible to spare the hippocampus and the rest of the limbic circuit using helical tomotherapy while treating the rest of the brain to full dose.

  12. Safety and Efficacy of Intensity-Modulated Stereotactic Body Radiotherapy Using Helical Tomotherapy for Lung Cancer and Lung Metastasis

    Directory of Open Access Journals (Sweden)

    Aiko Nagai

    2014-01-01

    Full Text Available Stereotactic body radiotherapy (SBRT proved to be an effective treatment with acceptable toxicity for lung tumors. However, the use of helical intensity-modulated (IM SBRT is controversial. We investigated the outcome of lung tumor patients treated by IMSBRT using helical tomotherapy with a Japanese standard fractionation schedule of 48 Gy in 4 fractions (n=37 or modified protocols of 50–60 Gy in 5–8 fractions (n=35. Median patient’s age was 76 years and median follow-up period for living patients was 20 months (range, 6–46. The median PTV was 6.9 cc in the 4-fraction group and 14 cc in the 5- to 8-fraction group (P=0.001. Grade 2 radiation pneumonitis was seen in 2 of 37 patients in the 4-fraction group and in 2 of 35 patients in the 5- to 8-fraction group (log-rank P=0.92. Other major complications were not observed. The LC rates at 2 years were 87% in the 4-fraction group and 83% in the 5- to 8-fraction group. Helical IMSBRT for lung tumors is safe and effective. Patients with a high risk of developing severe complications may also be safely treated using 5–8 fractions. The results of the current study warrant further studies of helical IMSBRT.

  13. Conversion of helical tomotherapy plans to step-and-shoot IMRT plans--Pareto front evaluation of plans from a new treatment planning system.

    Science.gov (United States)

    Petersson, Kristoffer; Ceberg, Crister; Engström, Per; Benedek, Hunor; Nilsson, Per; Knöös, Tommy

    2011-06-01

    The resulting plans from a new type of treatment planning system called SharePlan have been studied. This software allows for the conversion of treatment plans generated in a TomoTherapy system for helical delivery, into plans deliverable on C-arm linear accelerators (linacs), which is of particular interest for clinics with a single TomoTherapy unit. The purpose of this work was to evaluate and compare the plans generated in the SharePlan system with the original TomoTherapy plans and with plans produced in our clinical treatment planning system for intensity-modulated radiation therapy (IMRT) on C-arm linacs. In addition, we have analyzed how the agreement between SharePlan and TomoTherapy plans depends on the number of beams and the total number of segments used in the optimization. Optimized plans were generated for three prostate and three head-and-neck (H&N) cases in the TomoTherapy system, and in our clinical treatment planning systems (TPS) used for IMRT planning with step-and-shoot delivery. The TomoTherapy plans were converted into step-and-shoot IMRT plans in SharePlan. For each case, a large number of Pareto optimal plans were created to compare plans generated in SharePlan with plans generated in the Tomotherapy system and in the clinical TPS. In addition, plans were generated in SharePlan for the three head-and-neck cases to evaluate how the plan quality varied with the number of beams used. Plans were also generated with different number of beams and segments for other patient cases. This allowed for an evaluation of how to minimize the number of required segments in the converted IMRT plans without compromising the agreement between them and the original TomoTherapy plans. The plans made in SharePlan were as good as or better than plans from our clinical system, but they were not as good as the original TomoTherapy plans. This was true for both the head-and-neck and the prostate cases, although the differences between the plans for the latter were

  14. Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer

    International Nuclear Information System (INIS)

    Kim, Dae Woong; Kim, Jong Won; Choi, Yun Kyeong; Kim, Jung Soo; Hwang, Jae Woong; Jeong, Kyeong Sik; Choi, Gye Suk

    2008-01-01

    The goal of radiation treatment is to deliver a prescribed radiation dose to the target volume accurately while minimizing dose to normal tissues. In this paper, we comparing the dose distribution between three dimensional conformal radiation radiotherapy (3D-CRT) and helical tomotherapy (TOMO) plan for partial breast cancer. Twenty patients were included in the study, and plans for two techniques were developed for each patient (left breast:10 patients, right breast:10 patients). For each patient 3D-CRT planning was using pinnacle planning system, inverse plan was made using Tomotherapy Hi-Art system and using the same targets and optimization goals. We comparing the Homogeneity index (HI), Conformity index (CI) and sparing of the organs at risk for dose-volume histogram. Whereas the HI, CI of TOMO was significantly better than the other, 3D-CRT was observed to have significantly poorer HI, CI. The percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose was 3D-CRT (mean: 40.4%), TOMO (mean: 18.3%). The average ipsilateral lung volume percentage receiving 20% of the PD was 3D-CRT (mean: 4.8%), TOMO (mean: 14.2), concerning the average heart volume receiving 20% and 10% of the PD during treatment of left breast cancer 3D-CRT (mean: 1.6%, 3.0%), TOMO (mean: 9.7%, 26.3%) In summary, 3D-CRT and TOMO techniques were found to have acceptable PTV coverage in our study. However, in TOMO, high conformity to the PTV and effective breast tissue sparing was achieved at the expense of considerable dose exposure to the lung and heart.

  15. Helical tomotherapy for SIB and hypo-fractionated treatments in lung carcinomas: A 4D Monte Carlo treatment planning study

    International Nuclear Information System (INIS)

    Sterpin, Edmond; Janssens, Guillaume; Orban de Xivry, Jonathan; Goossens, Samuel; Wanet, Marie; Lee, John A.; Delor, Antoine; Bol, Vanesa; Vynckier, Stefaan; Gregoire, Vincent; Geets, Xavier

    2012-01-01

    Purpose: To evaluate the impact of intra-fraction motion induced by regular breathing on treatment quality for helical tomotherapy treatments. Material and methods: Four patients treated by simultaneous-integrated boost (SIB) and three by hypo-fractionated stereotactic treatments (hypo-fractionated, 18 Gy/fraction) were included. All patients were coached to ensure regular breathing. For the SIB group, the tumor volume was delineated using CT information only (CTV CT ) and the boost region was based on PET information (GTV PET , no CTV extension). In the hypo-fractionated group, a GTV based on CT information was contoured. In both groups, ITVs were defined according to 4D data. The PTV included the ITV plus a setup error margin. The treatment was planned using the tomotherapy TPS on 3D CT images. In order to verify the impact of intra-fraction motion and interplay effects, dose calculations were performed using a previously validated Monte Carlo model of tomotherapy (TomoPen): first on the planning 3D CT (“planned dose”) and second, on the 10 phases of the 4D scan. For the latter, two dose distributions, termed “interplay simulated” or “no interplay” were computed with and without beamlet-phase correlation over the 10 phases and combined using deformable dose registration. Results: In all cases, DVHs of “interplay simulated” dose distributions complied within 1% of the original clinical objectives used for planning, defined according to ICRU (report 83) and RTOG (trials 0236 and 0618) recommendations, for SIB and hypo-fractionated groups, respectively. For one patient in the hypo-fractionated group, D mean to the CTV CT was 2.6% and 2.5% higher than “planned” for “interplay simulated” and “no interplay”, respectively. Conclusion: For the patients included in this study, assuming regular breathing, the results showed that interplay of breathing and tomotherapy delivery motions did not affect significantly plan delivery accuracy. Hence

  16. Helical Tomotherapy Planning for Lung Cancer Based on Ventilation Magnetic Resonance Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cai Jing; McLawhorn, Robert [Department of Radiation Oncology, University of Virginia, Charlottesville, VA (United States); Altes, Tallisa A.; Lange, Eduard de [Department of Radiology, University of Virginia, Charlottesville, VA (United States); Read, Paul W.; Larner, James M.; Benedict, Stanley H. [Department of Radiation Oncology, University of Virginia, Charlottesville, VA (United States); Sheng Ke, E-mail: ks2mc@virginia.edu [Department of Radiation Oncology, University of Virginia, Charlottesville, VA (United States)

    2011-01-01

    To investigate the feasibility of lung ventilation-based treatment planning, computed tomography and hyperpolarized (HP) helium-3 (He-3) magnetic resonance imaging (MRI) ventilation images of 6 subjects were coregistered for intensity-modulated radiation therapy planning in Tomotherapy. Highly-functional lungs (HFL) and less-functional lungs (LFL) were contoured based on their ventilation image intensities, and a cylindrical planning-target-volume was simulated at locations adjacent to both HFL and LFL. Annals of an anatomy-based plan (Plan 1) and a ventilation-based plan (Plan 2) were generated. The following dosimetric parameters were determined and compared between the 2 plans: percentage of total/HFL volume receiving {>=}20 Gy, 15 Gy, 10 Gy, and 5 Gy (TLV{sub 20}, HFLV{sub 20}, TLV{sub 15}, HFLV{sub 15}, TLV{sub 10}, HFLV{sub 10}, TLV{sub 5}, HFLV{sub 5}), mean total/HFL dose (MTLD/HFLD), maximum doses to all organs at risk (OARs), and target dose conformality. Compared with Plan 1, Plan 2 reduced mean HFLD (mean reduction, 0.8 Gy), MTLD (mean reduction, 0.6 Gy), HFLV{sub 20} (mean reduction, 1.9%), TLV{sub 20} (mean reduction, 1.5%), TLV{sub 15} (mean reduction, 1.7%), and TLV{sub 10} (mean reduction, 2.1%). P-values of the above comparisons are less than 0.05 using the Wilcoxon signed rank test. For HFLV{sub 15}, HFLV{sub 10}, TLV{sub 5}, and HTLV{sub 5}, Plan 2 resulted in lower values than plan 1 but the differences are not significant (P-value range, 0.063-0.219). Plan 2 did not significantly change maximum doses to OARs (P-value range, 0.063-0.563) and target conformality (P = 1.000). HP He-3 MRI of patients with lung disease shows a highly heterogeneous ventilation capacity that can be utilized for functional treatment planning. Moderate but statistically significant improvements in sparing functional lungs were achieved using helical tomotherapy plans.

  17. A treatment planning study comparing helical tomotherapy with intensity-modulated radiotherapy for the treatment of anal cancer

    International Nuclear Information System (INIS)

    Joseph, Kurian Jones; Syme, Alasdair; Small, Cormac; Warkentin, Heather; Quon, Harvey; Ghosh, Sunita; Field, Colin; Pervez, Nadeem; Tankel, Keith; Patel, Samir; Usmani, Nawaid; Severin, Diane; Nijjar, Tirath; Fallone, Gino; Pedersen, John

    2010-01-01

    Purpose: A planning study to compare helical tomotherapy (HT) and intensity-modulated radiotherapy (IMRT) for the treatment of anal canal cancer. Materials and methods: Sixteen (8 males and 8 females) patients with anal cancer previously treated radically were identified. HT and IMRT plans were generated and dosimetric comparisons of the plans were performed. The planning goals were to deliver 54 Gy to the tumor (PTV 54Gy ) and 48 Gy to the nodes at risk (PTV Node ) in 30 fractions. Results: PTVs: HT plans were more homogeneous for both men and women. Male patients: HT vs. IMRT: D max : 55.87 ± 0.58 vs. 59.17 ± 3.24 (p = 0.036); D min : 52.91 ± 0.36 vs. 44.09 ± 6.84 (p = 0.012); female patients: HT vs. IMRT: D max : 56.14 ± 0.71 vs. 59.47 ± 0.81 (p = 0.012); D min : 52.36 ± 0.87 vs. 50.97 ± 1.42 (p = 0.028). OARs: In general, HT plans delivered a lower dose to the peritoneal cavity, external genitalia and the bladder and IMRT plans resulted in greater sparing of the pelvic bones (iliac crest/femur) for both men and women. Iliac crest/femur: the difference was significant only for the mean V10 Gy of iliac crest in women (p ≤ 0.012). External genitalia: HT plans achieved better sparing in women compared to men (p ≤ 0.046). For men, the mean doses were 18.96 ± 3.17 and 15.72 ± 3.21 for the HT and IMRT plan, respectively (p ≤ 0.017). Skin: both techniques achieved comparable sparing of the non-target skin (p = NS). Conclusions: HT and IMRT techniques achieved comparable target dose coverage and organ sparing, whereas HT plans were more homogeneous for both men and women.

  18. Evaluation of ovary dose for woman of childbearing age woman with breast cancer in tomotherapy

    International Nuclear Information System (INIS)

    Lee, Soo Hyeong; Park, Soo Yeon; Choi, Ji Min; Park, Ju Young; Kim, Jong Suk

    2014-01-01

    The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of 64.94±0.84 mGy and 37.64±1.20 mGy in left ovary part and average of 64.38±1.85 mGy and 32.96±1.11 mGy in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required

  19. Evaluation of ovary dose for woman of childbearing age woman with breast cancer in tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Hyeong; Park, Soo Yeon; Choi, Ji Min; Park, Ju Young; Kim, Jong Suk [Dept. of Radiation Oncology, Samsung Medical Center, Seoul (Korea, Republic of)

    2014-12-15

    The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of 64.94±0.84 mGy and 37.64±1.20 mGy in left ovary part and average of 64.38±1.85 mGy and 32.96±1.11 mGy in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required.

  20. Image-guided total-marrow irradiation using helical tomotherapy in patients with multiple myeloma and acute leukemia undergoing hematopoietic cell transplantation.

    Science.gov (United States)

    Wong, Jeffrey Y C; Rosenthal, Joseph; Liu, An; Schultheiss, Timothy; Forman, Stephen; Somlo, George

    2009-01-01

    Total-body irradiation (TBI) has an important role in patients undergoing hematopoietic cell transplantation (HCT), but is associated with significant toxicities. Targeted TBI using helical tomotherapy results in reduced doses to normal organs, which predicts for reduced toxicities compared with standard TBI. Thirteen patients with multiple myeloma were treated in an autologous tandem transplantation Phase I trial with high-dose melphalan, followed 6 weeks later by total-marrow irradiation (TMI) to skeletal bone. Dose levels were 10, 12, 14, and 16 Gy at 2 Gy daily/twice daily. In a separate allogeneic HCT trial, 8 patients (5 with acute myelogenous leukemia, 1 with acute lymphoblastic leukemia, 1 with non-Hodgkin's lymphoma, and 1 with multiple myeloma) were treated with TMI plus total lymphoid irradiation plus splenic radiotherapy to 12 Gy (1.5 Gy twice daily) combined with fludarabine/melphalan. For the 13 patients in the tandem autologous HCT trial, median age was 54 years (range, 42-66 years). Median organ doses were 15-65% that of the gross target volume dose. Primarily Grades 1-2 acute toxicities were observed. Six patients reported no vomiting; 9 patients, no mucositis; 6 patients, no fatigue; and 8 patients, no diarrhea. For the 8 patients in the allogeneic HCT trial, median age was 52 years (range, 24-61 years). Grades 2-3 nausea, vomiting, mucositis, and diarrhea were observed. In both trials, no Grade 4 nonhematologic toxicity was observed, and all patients underwent successful engraftment. This study shows that TMI using helical tomotherapy is clinically feasible. The reduced acute toxicities observed compare favorably with those seen with standard TBI. Initial results are encouraging and warrant further evaluation as a method to dose escalate with acceptable toxicity or to offer TBI-containing regimens to patients unable to tolerate standard approaches.

  1. Image-Guided Total-Marrow Irradiation Using Helical Tomotherapy in Patients With Multiple Myeloma and Acute Leukemia Undergoing Hematopoietic Cell Transplantation

    International Nuclear Information System (INIS)

    Wong, Jeffrey Y.C.; Rosenthal, Joseph; Liu An; Schultheiss, Timothy; Forman, Stephen; Somlo, George

    2009-01-01

    Purpose: Total-body irradiation (TBI) has an important role in patients undergoing hematopoietic cell transplantation (HCT), but is associated with significant toxicities. Targeted TBI using helical tomotherapy results in reduced doses to normal organs, which predicts for reduced toxicities compared with standard TBI. Methods and Materials: Thirteen patients with multiple myeloma were treated in an autologous tandem transplantation Phase I trial with high-dose melphalan, followed 6 weeks later by total-marrow irradiation (TMI) to skeletal bone. Dose levels were 10, 12, 14, and 16 Gy at 2 Gy daily/twice daily. In a separate allogeneic HCT trial, 8 patients (5 with acute myelogenous leukemia, 1 with acute lymphoblastic leukemia, 1 with non-Hodgkin's lymphoma, and 1 with multiple myeloma) were treated with TMI plus total lymphoid irradiation plus splenic radiotherapy to 12 Gy (1.5 Gy twice daily) combined with fludarabine/melphalan. Results: For the 13 patients in the tandem autologous HCT trial, median age was 54 years (range, 42-66 years). Median organ doses were 15-65% that of the gross target volume dose. Primarily Grades 1-2 acute toxicities were observed. Six patients reported no vomiting; 9 patients, no mucositis; 6 patients, no fatigue; and 8 patients, no diarrhea. For the 8 patients in the allogeneic HCT trial, median age was 52 years (range, 24-61 years). Grades 2-3 nausea, vomiting, mucositis, and diarrhea were observed. In both trials, no Grade 4 nonhematologic toxicity was observed, and all patients underwent successful engraftment. Conclusions: This study shows that TMI using helical tomotherapy is clinically feasible. The reduced acute toxicities observed compare favorably with those seen with standard TBI. Initial results are encouraging and warrant further evaluation as a method to dose escalate with acceptable toxicity or to offer TBI-containing regimens to patients unable to tolerate standard approaches

  2. Helical Tomotherapy in Children and Adolescents: Dosimetric Comparisons, Opportunities and Issues

    Energy Technology Data Exchange (ETDEWEB)

    Mascarin, Maurizio, E-mail: mascarin@cro.it [Pediatric Radiotherapy Unit, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Department of Radiation Therapy, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Giugliano, Francesca Maria [Pediatric Radiotherapy Unit, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Seconda Università di Napoli, Napoli 80138 (Italy); Coassin, Elisa [Pediatric Radiotherapy Unit, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Drigo, Annalisa; Chiovati, Paola; Dassie, Andrea [Department of Radiation Therapy, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Department of Medical Physics, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Franchin, Giovanni; Minatel, Emilio; Trovò, Mauro Gaetano [Department of Radiation Therapy, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy)

    2011-10-25

    Helical Tomotherapy (HT) is a highly conformal image-guided radiation technique, introduced into clinical routine in 2006 at the Centro di Riferimento Oncologico Aviano (Italy). With this new technology, intensity-modulated radiotherapy (IMRT) is delivered using a helicoidal method. Here we present our dosimetric experiences using HT in 100 children, adolescents and young adults treated from May 2006 to February 2011. The median age of the patients was 13 years (range 1–24). The most common treated site was the central nervous system (50; of these, 24 were craniospinal irradiations), followed by thorax (22), head and neck (10), abdomen and pelvis (11), and limbs (7). The use of HT was calculated in accordance to the target dose conformation, the target size and shape, the dose to critical organs adjacent to the target, simultaneous treatment of multiple targets, and re-irradiation. HT has demonstrated to improve target volume dose homogeneity and the sparing of critical structures, when compared to 3D Linac-based radiotherapy (RT). In standard cases this technique represented a comparable alternative to IMRT delivered with conventional linear accelerator. In certain cases (e.g., craniospinal and pleural treatments) only HT generated adequate treatment plans with good target volume coverage. However, the gain in target conformality should be balanced with the spread of low-doses to distant areas. This remains an open issue for the potential risk of secondary malignancies (SMNs) and longer follow-up is mandatory.

  3. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, David, E-mail: d-pasquier@o-lambret.fr [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Centre Galilee, Clinique de la Louviere, Lille (France); Cavillon, Fabrice [Universite Lille Nord de France, Lille (France); Faculte Libre de Medecine, Lille (France); Lacornerie, Thomas [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Touzeau, Claire [Centre Galilee, Clinique de la Louviere, Lille (France); Tresch, Emmanuelle [Unite de Methodologie et Biostatistique, Centre O. Lambret, Lille (France); Lartigau, Eric [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France)

    2013-02-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  4. Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Harmon, Joseph F. Jr.; Langen, Katja M.; Willoughby, Twyla R.; Wagner, Thomas H.; Kupelian, Patrick A.

    2005-01-01

    Helical tomotherapy is an innovative means of delivering IGRT and IMRT using a device that combines features of a linear accelerator and a helical computed tomography (CT) scanner. The HI-ART II can generate CT images from the same megavoltage x-ray beam it uses for treatment. These megavoltage CT (MVCT) images offer verification of the patient position prior to and potentially during radiation therapy. Since the unit uses the actual treatment beam as the x-ray source for image acquisition, no surrogate telemetry systems are required to register image space to treatment space. The disadvantage to using the treatment beam for imaging, however, is that the physics of radiation interactions in the megavoltage energy range may force compromises between the dose delivered and the image quality in comparison to diagnostic CT scanners. The performance of the system is therefore characterized in terms of objective measures of noise, uniformity, contrast, and spatial resolution as a function of the dose delivered by the MVCT beam. The uniformity and spatial resolutions of MVCT images generated by the HI-ART II are comparable to that of diagnostic CT images. Furthermore, the MVCT scan contrast is linear with respect to the electron density of material imaged. MVCT images do not have the same performance characteristics as state-of-the art diagnostic CT scanners when one objectively examines noise and low-contrast resolution. These inferior results may be explained, at least partially, by the low doses delivered by our unit; the dose is 1.1 cGy in a 20 cm diameter cylindrical phantom. In spite of the poorer low-contrast resolution, these relatively low-dose MVCT scans provide sufficient contrast to delineate many soft-tissue structures. Hence, these images are useful not only for verifying the patient's position at the time of therapy, but they are also sufficient for delineating many anatomic structures. In conjunction with the ability to recalculate radiotherapy doses on

  5. SU-F-T-267: A Clarkson-Based Independent Dose Verification for the Helical Tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, H [Shonan Kamakura General Hospital, Kamakura, Kanagawa, (Japan); Juntendo University, Hongo, Tokyo (Japan); Hongo, H [Shonan Kamakura General Hospital, Kamakura, Kanagawa, (Japan); Tsukuba University, Tsukuba, Ibaraki (Japan); Kawai, D [Kanagawa Cancer Center, Yokohama, Kanagawa (Japan); Takahashi, R [Cancer Institute Hospital of Japanese Foundation for Cancer Research, Koto, Tokyo (Japan); Hashimoto, H [Shonan Fujisawa Tokushukai Hospital, Fujisawa, Kanagawa (Japan); Tachibana, H [National Cancer Center, Kashiwa, Chiba (Japan)

    2016-06-15

    Purpose: There have been few reports for independent dose verification for Tomotherapy. We evaluated the accuracy and the effectiveness of an independent dose verification system for the Tomotherapy. Methods: Simple MU Analysis (SMU, Triangle Product, Ishikawa, Japan) was used as the independent verification system and the system implemented a Clarkson-based dose calculation algorithm using CT image dataset. For dose calculation in the SMU, the Tomotherapy machine-specific dosimetric parameters (TMR, Scp, OAR and MLC transmission factor) were registered as the machine beam data. Dose calculation was performed after Tomotherapy sinogram from DICOM-RT plan information was converted to the information for MU and MLC location at more segmented control points. The performance of the SMU was assessed by a point dose measurement in non-IMRT and IMRT plans (simple target and mock prostate plans). Subsequently, 30 patients’ treatment plans for prostate were compared. Results: From the comparison, dose differences between the SMU and the measurement were within 3% for all cases in non-IMRT plans. In the IMRT plan for the simple target, the differences (Average±1SD) were −0.70±1.10% (SMU vs. TPS), −0.40±0.10% (measurement vs. TPS) and −1.20±1.00% (measurement vs. SMU), respectively. For the mock prostate, the differences were −0.40±0.60% (SMU vs. TPS), −0.50±0.90% (measurement vs. TPS) and −0.90±0.60% (measurement vs. SMU), respectively. For patients’ plans, the difference was −0.50±2.10% (SMU vs. TPS). Conclusion: A Clarkson-based independent dose verification for the Tomotherapy can be clinically available as a secondary check with the similar tolerance level of AAPM Task group 114. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

  6. Clinical effectiveness, toxicity, and failure patterns of helical tomotherapy for postoperative oral cavity cancer patients

    Directory of Open Access Journals (Sweden)

    Hsieh CH

    2014-03-01

    Full Text Available Chen-Hsi Hsieh,1–3 Pei-Wei Shueng,1,4 Li-Ying Wang,5 Li-Jen Liao,6 Yu-Chin Lin,7 Ying-Shiung Kuo,8 Wu-Chia Lo,6 Chien-Fu Tseng,8 Hui-Ju Tien,1 Hsiu-Ling Chou,9,10 Yen-Ping Hsieh,11 Le-Jung Wu,1 Yu-Jen Chen3,12–14 1Department of Radiation Oncology, Far Eastern Memorial Hospital, 2Department of Medicine, 3Institute of Traditional Medicine, School of Medicine, National Yang-Ming University, 4Department of Radiation Oncology, National Defense Medical Center, 5School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, 6Department of Otolaryngology, 7Division of Medical Oncology and Hematology, Department of Internal Medicine, 8Department of Dentistry and Oral Surgery, 9Department of Nursing, Far Eastern Memorial Hospital, 10Department of Nursing, Oriental Institute of Technology, Taipei, 11Department of Senior Citizen Service Management, National Taichung University of Science and Technology, Taichung, 12Department of Radiation Oncology, 13Department of Medical Research, Mackay Memorial Hospital, 14Graduate Institute of Sport Coaching Science, Chinese Culture University, Taipei, Taiwan Background: The outcome of postoperative high- and intermediate-risk oral cavity cancer (OCC patients receiving helical tomotherapy (HT remains limited. Materials and methods: Between November 2006 and November 2012, 53 postoperative high- and intermediate-risk OCC patients treated with HT were enrolled. Results: The 4-year locoregional, local, and regional control rates were 66%, 76.4%, and 94.3%, respectively. The 4-year locoregional control rates of oral tongue and buccal mucosa cancer were 88.3% and 37.1%, respectively (P=0.012. Eleven (20.8% patients experienced locoregional failure. In-field failure occurred in six of 53 (11.3% in the primary area and three of 53 (5.7% in the regional lymph-node area. No marginal failure was noted. Two of 53 (3.8% experienced out-of-field failure. The rates of grade 3 dermatitis

  7. Daily measure of the constancy of rotation in the evaluation of geometric and dosimetric parameters of the tomotherapy

    International Nuclear Information System (INIS)

    Erzilbengoa, M.; Moral, S.; Bragado, L.; Guisasola, M. A.

    2011-01-01

    The daily test performance called ''Rotating Constancia'', based on the methodology developed by Balog ''Helical tomotherapy dynamic quality assurance'' (2006), has allowed us over these 2 years to assess the response to TomoTherapy machine parameters given dose, travel speed table offset of the same, position of the green lasers, field size, rotation time and energy index of the beam parameters can be measured without intensity modulation.

  8. Design and implementation of a ''cheese'' phantom-based Tomotherapy TLD dose intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Schiefer, Hans; Buchauer, Konrad; Heinze, Simon [Medical Physics Group, Department of Radiation Oncology, St. Gallen (Switzerland); Henke, Guido; Plasswilm, Ludwig [Department of Radiation Oncology, St. Gallen (Switzerland)

    2015-11-15

    The unique beam-delivery technique of Tomotherapy machines (Accuray Inc., Sunnyvale, Calif.) necessitates tailored quality assurance. This requirement also applies to external dose intercomparisons. Therefore, the aim of the 2014 SSRMP (Swiss Society of Radiobiology and Medical Physics) dosimetry intercomparison was to compare two set-ups with different phantoms. A small cylindrical Perspex phantom, which is similar to the IROC phantom (Imaging and Radiation Oncology Core, Houston, Tex.), and the ''cheese'' phantom, which is provided by the Tomotherapy manufacturer to all institutions, were used. The standard calibration plans for the TomoHelical and TomoDirect irradiation techniques were applied. These plans are routinely used for dose output calibration in Tomotherapy institutions. We tested 20 Tomotherapy machines in Germany and Switzerland. The ratio of the measured (D{sub m}) to the calculated (D{sub c}) dose was assessed for both phantoms and irradiation techniques. The D{sub m}/D{sub c} distributions were determined to compare the suitability of the measurement set-ups investigated. The standard deviations of the TLD-measured (thermoluminescent dosimetry) D{sub m}/D{sub c} ratios for the ''cheese'' phantom were 1.9 % for the TomoHelical (19 measurements) and 1.2 % (11 measurements) for the TomoDirect irradiation techniques. The corresponding ratios for the Perspex phantom were 2.8 % (18 measurements) and 1.8 % (11 measurements). Compared with the Perspex phantom-based set-up, the ''cheese'' phantom-based set-up without individual planning was demonstrated to be more suitable for Tomotherapy dose checks. Future SSRMP dosimetry intercomparisons for Tomotherapy machines will therefore be based on the ''cheese'' phantom set-up. (orig.) [German] Die einzigartige Bestrahlungstechnik mit Tomotherapie-Bestrahlungsgeraeten (Accuray Inc., Sunnyvale, CA, USA) erfordert spezifische

  9. Longitudinal assessment of parotid function in patients receiving tomotherapy for head-and-neck cancer

    International Nuclear Information System (INIS)

    Voordeckers, M.; Tournel, K.; Verellen, D.; Esch, G. van; Storme, G.; Everaert, H.; Vanhove, C.; Baron, I.

    2008-01-01

    Background and purpose: conventional radiotherapy is associated with high doses to the salivary glands which causes xerostomia and adverse effects on quality of life. The study aims to investigate the potential of helical tomotherapy (Hi-Art Tomotherapy registered ) to preserve parotid function in head-and-neck cancer patients. Patients and methods: seven consecutive patients treated with helical tomotherapy at the UZ Brussel, Belgium, were included. During planning, priority was attributed to planning target volume (PTV) coverage: ≥ 95% of the dose must be delivered to ≥ 95% of the PTV. Elective nodal regions received 54 Gy (1.8 Gy/fraction). A dose of 70.5 Gy (2.35 Gy/fraction) was prescribed to the primary tumor and pathologic lymph nodes = simultaneous integrated boost scheme. If possible, the mean parotid dose was kept below 26 Gy. Salivary gland function was assessed by technetium scintigraphy. Results: there was a significant dose-response relationship between mean parotid dose and functional recuperation. If the mean dose was kept 26 %). In order to preserve 75% of SE, 46% of the parotid volume should receive a dose 26 Gy can be reduced. (orig.)

  10. Image-guided intensity modulated radiotherapy with helical tomotherapy for postoperative treatment of high-risk oral cavity cancer

    International Nuclear Information System (INIS)

    Hsieh, Chen-Hsi; Hsieh, Yen-Ping; Lin, Shoei Long; Chen, Chun-Yi; Chen, Chien-An; Shueng, Pei-Wei; Kuo, Ying-Shiung; Liao, Li-Jen; Hu, Kawang-Yu; Lin, Shih-Chiang; Wu, Le-Jung; Lin, Yu-Chin; Chen, Yu-Jen; Wang, Li-Ying

    2011-01-01

    The aim of this study was to assess the treatment results and toxicity profiles of helical tomotherapy (HT) for postoperative high-risk oral cavity cancer. From December 6, 2006 through October 9, 2009, 19 postoperative high-risk oral cavity cancer patients were enrolled. All of the patients received HT with (84%) or without (16%) chemotherapy. The median follow-up time was 17 months. The 2-year overall survival, disease-free survival, locoregional control, and distant metastasis-free rates were 94%, 84%, 92%, and 94%, respectively. The package of overall treatment time > 13 wk, the interval between surgery and radiation ≤ 6 wk, and the overall treatment time of radiation ≤ 7 wk was 21%, 84%, and 79%, respectively. The percentage of grade 3 mucositis, dermatitis, and leucopenia was 42%, 5% and 5%, respectively. HT achieved encouraging clinical outcomes for postoperative high-risk oral cavity cancer patients with high compliance. A long-term follow-up study is needed to confirm these preliminary findings

  11. The role of helical tomotherapy in the treatment of bone plasmacytoma

    International Nuclear Information System (INIS)

    Chargari, Cyrus; Hijal, Tarek; Bouscary, Didier; Caussa, Lucas; Dendale, Remi; Zefkili, Sofia; Fourquet, Alain; Kirova, Youlia M.

    2012-01-01

    We evaluated the early clinical outcome of patients with solitary bone plasmacytoma (SP) or a solitary lesion of multiple myeloma (MM) treated with helical tomotherapy (HT) compared with 3D conformal radiotherapy (3D-CRT), in terms of target coverage and exposure of critical organs. Ten patients with SP and 3 patients with a solitary lesion of MM underwent radiation therapy (RT) delivered by HT, to a dose of 40 Gy in 20 fractions. Treatment planning was then performed with 3D-CRT and the dosimetric parameters of both techniques were compared. Patients were also assessed for response to treatment and acute toxicities. With a median follow-up of 13 months, 78% of patients with pain before RT had resolution of their symptoms. Coverage of target lesion was adequate with both techniques in 12 of 13 patients. Target coverage was significantly lower for HT (V 95% = 98.55% vs. 97.15%; p = 0.04, for 3D-CRT and HT, respectively). Target overdoses were also lower with HT (V 105% = 2.01% vs. 0.19%; p= 0.16), although nonsignificant. Finally, there were no significant differences in organs-at-risk irradiation between both techniques. The early treatment tolerance was excellent, with no toxicity higher than grade I. RT of SP and MM with a solitary lesion can be safely delivered with HT, with no major acute side effects and good symptomatic control. Finally, HT provides a dosimetry similar to that of 3D-CRT in terms of organs-at-risk sparing and target volume coverage.

  12. The role of helical tomotherapy in the treatment of bone plasmacytoma

    Energy Technology Data Exchange (ETDEWEB)

    Chargari, Cyrus; Hijal, Tarek [Department of Radiation Oncology, Institut Curie, Paris (France); Bouscary, Didier [Department of Hematology, Hopital Cochin, Paris (France); Caussa, Lucas; Dendale, Remi; Zefkili, Sofia; Fourquet, Alain [Department of Radiation Oncology, Institut Curie, Paris (France); Kirova, Youlia M., E-mail: youlia.kirova@curie.net [Department of Radiation Oncology, Institut Curie, Paris (France)

    2012-04-01

    We evaluated the early clinical outcome of patients with solitary bone plasmacytoma (SP) or a solitary lesion of multiple myeloma (MM) treated with helical tomotherapy (HT) compared with 3D conformal radiotherapy (3D-CRT), in terms of target coverage and exposure of critical organs. Ten patients with SP and 3 patients with a solitary lesion of MM underwent radiation therapy (RT) delivered by HT, to a dose of 40 Gy in 20 fractions. Treatment planning was then performed with 3D-CRT and the dosimetric parameters of both techniques were compared. Patients were also assessed for response to treatment and acute toxicities. With a median follow-up of 13 months, 78% of patients with pain before RT had resolution of their symptoms. Coverage of target lesion was adequate with both techniques in 12 of 13 patients. Target coverage was significantly lower for HT (V{sub 95%} = 98.55% vs. 97.15%; p = 0.04, for 3D-CRT and HT, respectively). Target overdoses were also lower with HT (V{sub 105%} = 2.01% vs. 0.19%; p= 0.16), although nonsignificant. Finally, there were no significant differences in organs-at-risk irradiation between both techniques. The early treatment tolerance was excellent, with no toxicity higher than grade I. RT of SP and MM with a solitary lesion can be safely delivered with HT, with no major acute side effects and good symptomatic control. Finally, HT provides a dosimetry similar to that of 3D-CRT in terms of organs-at-risk sparing and target volume coverage.

  13. A Monte Carlo derived TG-51 equivalent calibration for helical tomotherapy

    International Nuclear Information System (INIS)

    Thomas, S.D.; Mackenzie, M.; Rogers, D.W.O.; Fallone, B.G.

    2005-01-01

    Helical tomotherapy (HT) requires a method of accurately determining the absorbed dose under reference conditions. In the AAPM's TG-51 external beam dosimetry protocol, the quality conversion factor, k Q , is presented as a function of the photon component of the percentage depth-dose at 10 cm depth, %dd(10) x , measured under the reference conditions of a 10x10 cm 2 field size and a source-to-surface distance (SSD) of 100 cm. The value of %dd(10) x from HT cannot be used for the determination of k Q because the design of the HT does not meet the following TG-51 reference conditions: (i) the field size and the practical SSD required by TG-51 are not obtainable and (ii) the absence of the flattening filter changes the beam quality thus affecting some components of k Q . The stopping power ratio is not affected because of its direct relationship to %dd(10) x . We derive a relationship for the Exradin A1SL ion chamber converting the %dd(10) x measured under HT 'reference conditions' of SSD=85 cm and a 5x10 cm 2 field-size [%dd(10) x[HTRef] ], to the dosimetric equivalent value under for TG-51 reference conditions [%dd(10) x[HTTG-51] ] for HT. This allows the determination of k Q under the HT reference conditions. The conversion results in changes of 0.1% in the value of k Q for our particular unit. The conversion relationship should also apply to other ion chambers with possible errors on the order of 0.1%

  14. Investigating output and energy variations and their relationship to delivery QA results using Statistical Process Control for helical tomotherapy.

    Science.gov (United States)

    Binny, Diana; Mezzenga, Emilio; Lancaster, Craig M; Trapp, Jamie V; Kairn, Tanya; Crowe, Scott B

    2017-06-01

    The aims of this study were to investigate machine beam parameters using the TomoTherapy quality assurance (TQA) tool, establish a correlation to patient delivery quality assurance results and to evaluate the relationship between energy variations detected using different TQA modules. TQA daily measurement results from two treatment machines for periods of up to 4years were acquired. Analyses of beam quality, helical and static output variations were made. Variations from planned dose were also analysed using Statistical Process Control (SPC) technique and their relationship to output trends were studied. Energy variations appeared to be one of the contributing factors to delivery output dose seen in the analysis. Ion chamber measurements were reliable indicators of energy and output variations and were linear with patient dose verifications. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  15. Prostate cancer treated with image-guided helical TomoTherapy {sup registered} and image-guided LINAC-IMRT. Correlation between high-dose bladder volume, margin reduction, and genitourinary toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Drozdz, Sonia; Wendt, Thomas G. [University Hospital Jena, Friedrich-Schiller-University Jena, Department of Radiation Oncology, Jena (Germany); Schwedas, Michael; Salz, Henning [University Hospital Jena, Friedrich-Schiller-University Jena, Department of Radiation Oncology, Section of Medical Physics, Jena (Germany); Foller, Susan [University Hospital Jena, Friedrich-Schiller-University Jena, Department of Urology, Jena (Germany)

    2016-04-15

    We compared different image-guidance (IG) strategies for prostate cancer with high-precision IG intensity-modulated radiation therapy (IMRT) using TomoTherapy {sup registered} (Accuray Inc., Madison, WI, USA) and linear accelerator (LINAC)-IMRT and their impact on planning target volume (PTV) margin reduction. Follow-up data showed reduced bladder toxicity in TomoTherapy patients compared to LINAC-IMRT. The purpose of this study was to quantify whether the treatment delivery technique and decreased margins affect reductions in bladder toxicity. Setup corrections from 30 patients treated with helical TomoTherapy and 30 treated with a LINAC were analyzed. These data were used to simulate three IG protocols based on setup error correction and a limited number of imaging sessions. For all patients, gastrointestinal (GI) and genitourinary (GU) toxicity was documented and correlated with the treatment delivery technique. For fiducial marker (FM)-based RT, a margin reduction of up to 3.1, 3.0, and 4.8 mm in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, respectively, could be achieved with calculation of a setup correction from the first three fractions and IG every second day. Although the bladder volume was treated with mean doses of 35 Gy in the TomoTherapy group vs. 22 Gy in the LINAC group, we observed less GU toxicity after TomoTherapy. Intraprostate FMs allow for small safety margins, help decrease imaging frequency after setup correction, and minimize the dose to bladder and rectum, resulting in lower GU toxicity. In addition, IMRT delivered with TomoTherapy helps to avoid hotspots in the bladder neck, a critical anatomic structure associated with post-RT urinary toxicity. (orig.) [German] Wir haben im Rahmen der Prostatakarzinombehandlung verschiedene bildgefuehrte (IG) Strategien der hochpraezisen intensitaetsmodulierten Radiotherapie (IMRT) unter Einsatz der Tomotherapie (TomoTherapy {sup registered}, Accuray Inc., Madison

  16. Helical tomotherapy with dynamic running-start-stop delivery compared to conventional tomotherapy delivery

    International Nuclear Information System (INIS)

    Rong, Yi; Chen, Yu; Lu, Weiguo; Shang, Lu; Zuo, Li; Chen, Quan

    2014-01-01

    Purpose: Despite superior target dose uniformity, helical tomotherapy ® (HT) may involve a trade-off between longitudinal dose conformity and beam-on time (BOT), due to the limitation of only three available jaw sizes with the conventional HT (1.0, 2.5, and 5.0 cm). The recently introduced dynamic running-start-stop (RSS) delivery allows smaller jaw opening at the superior and inferior ends of the target when a sharp penumbra is needed. This study compared the dosimetric performance of RSS delivery with the fixed jaw HT delivery. Methods: Twenty patient cases were selected and deidentified prior to treatment planning, including 16 common clinical cases (brain, head and neck (HN), lung, and prostate) and four special cases of whole brain with hippocampus avoidance (WBHA) that require a high degree of dose modulation. HT plans were generated for common clinical cases using the fixed 2.5 cm jaw width (HT2.5) and WBHA cases using 1.0 cm (HT1.0). The jaw widths for RSS were preset with a larger size (RSS5.0 vs HT2.5 and RSS2.5 vs HT1.0). Both delivery techniques were planned based on identical contours, prescriptions, and planning objectives. Dose indices for targets and critical organs were compared using dose-volume histograms, BOT, and monitor units. Results: The average BOT was reduced from 4.8 min with HT2.5 to 2.5 min with RSS5.0. Target dose homogeneity with RSS5.0 was shown comparable to HT2.5 for common clinical sites. Superior normal tissue sparing was observed in RSS5.0 for optic nerves and optic chiasm in brain and HN cases. RSS5.0 demonstrated improved dose sparing for cord and esophagus in lung cases, as well as penile bulb in prostate cases. The mean body dose was comparable for both techniques. For the WBHA cases, the target homogeneity was significantly degraded in RSS2.5 without distinct dose sparing for hippocampus, compared to HT1.0. Conclusions: Compared to the fixed jaw HT delivery, RSS combined with a larger jaw width provides faster treatment

  17. Helical tomotherapy with dynamic running-start-stop delivery compared to conventional tomotherapy delivery

    Energy Technology Data Exchange (ETDEWEB)

    Rong, Yi, E-mail: yi.rong@osumc.edu [Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, Ohio 43210 (United States); Chen, Yu; Lu, Weiguo [21st Century Oncology, Madison, Wisconsin 53719 (United States); Shang, Lu [Guangxi Polytechnic of Construction and Technology, Nanning (China); Zuo, Li [Radiologic Sciences and Respiratory Therapy Division, School of Health and Rehabilitation Sciences, The Ohio State University College of Medicine, Columbus, Ohio 43210 (United States); Chen, Quan [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia 22904 (United States)

    2014-05-15

    Purpose: Despite superior target dose uniformity, helical tomotherapy{sup ®} (HT) may involve a trade-off between longitudinal dose conformity and beam-on time (BOT), due to the limitation of only three available jaw sizes with the conventional HT (1.0, 2.5, and 5.0 cm). The recently introduced dynamic running-start-stop (RSS) delivery allows smaller jaw opening at the superior and inferior ends of the target when a sharp penumbra is needed. This study compared the dosimetric performance of RSS delivery with the fixed jaw HT delivery. Methods: Twenty patient cases were selected and deidentified prior to treatment planning, including 16 common clinical cases (brain, head and neck (HN), lung, and prostate) and four special cases of whole brain with hippocampus avoidance (WBHA) that require a high degree of dose modulation. HT plans were generated for common clinical cases using the fixed 2.5 cm jaw width (HT2.5) and WBHA cases using 1.0 cm (HT1.0). The jaw widths for RSS were preset with a larger size (RSS5.0 vs HT2.5 and RSS2.5 vs HT1.0). Both delivery techniques were planned based on identical contours, prescriptions, and planning objectives. Dose indices for targets and critical organs were compared using dose-volume histograms, BOT, and monitor units. Results: The average BOT was reduced from 4.8 min with HT2.5 to 2.5 min with RSS5.0. Target dose homogeneity with RSS5.0 was shown comparable to HT2.5 for common clinical sites. Superior normal tissue sparing was observed in RSS5.0 for optic nerves and optic chiasm in brain and HN cases. RSS5.0 demonstrated improved dose sparing for cord and esophagus in lung cases, as well as penile bulb in prostate cases. The mean body dose was comparable for both techniques. For the WBHA cases, the target homogeneity was significantly degraded in RSS2.5 without distinct dose sparing for hippocampus, compared to HT1.0. Conclusions: Compared to the fixed jaw HT delivery, RSS combined with a larger jaw width provides faster

  18. Dose-Volume Relationships for Acute Bowel Toxicity in Patients Treated With Pelvic Nodal Irradiation for Prostate Cancer

    International Nuclear Information System (INIS)

    Fiorino, Claudio; Alongi, Filippo; Perna, Lucia; Broggi, Sara; Cattaneo, Giovanni Mauro; Cozzarini, Cesare; Di Muzio, Nadia; Fazio, Ferruccio; Calandrino, Riccardo

    2009-01-01

    Purpose: To find correlation between dose-volume histograms (DVHs) of the intestinal cavity (IC) and moderate-severe acute bowel toxicity in men with prostate cancer treated with pelvic nodal irradiation. Methods and Materials: The study group consisted of 191 patients with localized prostate cancer who underwent whole-pelvis radiotherapy with radical or adjuvant/salvage intent during January 2004 to November 2007. Complete planning/clinical data were available in 175 of these men, 91 of whom were treated with a conventional four-field technique (50.4 Gy, 1.8 Gy/fraction) and 84 of whom were treated with IMRT using conventional Linac (n = 26, 50.4 Gy, 1.8 Gy/fraction) or Helical TomoTherapy (n = 58, 50-54 Gy, 1.8-2 Gy/fraction). The IC outside the planning target volume (PTV) was contoured and the DVH for the first 6 weeks of treatment was recovered in all patients. The correlation between a number of clinical and DVH (V10-V55) variables and toxicity was investigated in univariate and multivariate analyses. The correlation between DVHs for the IC outside the PTV and DVHs for the whole IC was also assessed. Results: Twenty-two patients experienced toxicity (3/22 in the IMRT/tomotherapy group). Univariate analyses showed a significant correlation between V20-V50 and toxicity (p = 0.0002-0.001), with a higher predictive value observed for V40-V50. Previous prostatectomy (p = 0.066) and abdominal/pelvic surgery (p = 0.12) also correlated with toxicity. Multivariate analysis that included V45, abdominal/pelvic surgery, and prostatectomy showed that the most predictive parameters were V45 (p = 0.002) and abdominal/pelvic surgery (p = 0.05, HR = 2.4) Conclusions: Our avoidance IMRT approach drastically reduces the incidence of acute bowel toxicity. V40-V50 of IC and, secondarily, previous abdominal/pelvic surgery were the main predictors of acute bowel toxicity.

  19. Advances in the implementation of helical tomotherapy-based total marrow irradiation with a novel field junction technique

    Energy Technology Data Exchange (ETDEWEB)

    Zeverino, Michele, E-mail: michele.zeverino@istge.it [Medical Physics Department, IRCCS, Istituto Nazionale per la Ricerca sul cancro, Genoa (Italy); Agostinelli, Stefano; Taccini, Gianni; Cavagnetto, Francesca; Garelli, Stefania; Gusinu, Marco [Medical Physics Department, IRCCS, Istituto Nazionale per la Ricerca sul cancro, Genoa (Italy); Vagge, Stefano; Barra, Salvina; Corvo, Renzo [Radiation Oncology Department, IRCCS, Istituto Nazionale per la Ricerca sul cancro, Genoa (Italy)

    2012-10-01

    Given the limitations in the travel ability of the helical tomotherapy (HT) couch, total marrow irradiation (TMI) has to be split in 2 segments, with the lower limbs treated with feet first orientation. The aim of this work is to present a planning technique useful to reduce the dose inhomogeneity resulting from the matching of the 2 helical dose distributions. Three HT plans were generated for each of the 18 patients enrolled. Upper TMI (UTMI) and lower TMI (LTMI) were planned onto the whole-body computed tomography (CT) and on the lower-limb CT, respectively. A twin lower TMI plan (tLTMI) was designed on the whole-body CT. Agreement between LTMI and tLTMI plans was assessed by computing for each dose-volume histogram (DVH) structure the {gamma} index scored with 1% of dose and volume difference thresholds. UTMI and tLTMI plans were summed together on the whole-body CT, enabling the evaluation of dose inhomogeneity. Moreover, a couple of transition volumes were used to improve the dose uniformity in the abutment region. For every DVH, a number of points >99% passed the {gamma} analysis, validating the method used to generate the twin plan. The planned dose inhomogeneity at the junction level resulted within {+-}10% of the prescribed dose. Median dose reduction to organs at risk ranged from 30-80% of the prescribed dose. Mean conformity index was 1.41 (range 1.36-1.44) for the whole-body target. The technique provided a 'full helical' dose distribution for TMI treatments, which can be considered effective only if the dose agreement between LTMI and tLTMI plans is met. The planning of TMI with HT for the whole body with adequate dose homogeneity and conformity was shown to be feasible.

  20. Radiotherapy for Adult Medulloblastoma: Evaluation of Helical Tomotherapy, Volumetric Intensity Modulated Arc Therapy, and Three-Dimensional Conformal Radiotherapy and the Results of Helical Tomotherapy Therapy

    Directory of Open Access Journals (Sweden)

    Sun Zong-wen

    2018-01-01

    Full Text Available Introduction. All adult medulloblastoma (AMB patients should be treated with craniospinal irradiation (CSI postoperatively. Because of the long irradiation range, multiple radiation fields must be designed for conventional radiotherapy technology. CSI can be completed in only one session with helical tomotherapy (HT. We evaluated the dose of HT, volumetric intensity modulated arc therapy (VMAT, and three-dimensional conformal radiotherapy (3D-CRT of AMB and the results of 5 cases of AMB treated with HT. Methods. Complete craniospinal and posterior cranial fossa irradiation with HT, VMAT, and 3D-CRT and dose evaluation were performed. And results of 5 cases of AMB treated with HT were evaluated. Results. A large volume of tissue was exposed to low dose radiation in the organs at risk (OAR, while a small volume was exposed to high dose radiation with HT. The conformity and uniformity of the targets were good with HT and VMAT, and the volume of targets exposed to high dose with VMAT was larger than that of HT. The uniformity of 3D-CRT was also good, but the dose conformity was poor. The main toxicity was hematologic toxicity, without 4th-degree bone marrow suppression. There was 3rd-degree inhibition in the white blood cells, hemoglobin, and platelets. The three female patients suffered menstrual disorders during the course of radiation. Two female patients with heavy menstruation suffered 3rd-degree anemia inhibition, and 2 patients suffered amenorrhea after radiotherapy. Although menstrual cycle was normal, the third patient was not pregnant. Conclusion. CSI with HT is convenient for clinical practice, and the side effects are mild. With good conformity and uniformity, VMAT can also be used for selection in CSI. For poor conformity, 3D-CRT should not be the priority selection for CSI. In female patients, the ovaries should be protected.

  1. Helical Tomotherapy-Based STAT Stereotactic Body Radiation Therapy: Dosimetric Evaluation for a Real-Time SBRT Treatment Planning and Delivery Program

    International Nuclear Information System (INIS)

    Dunlap, Neal; McIntosh, Alyson; Sheng Ke; Yang Wensha; Turner, Benton; Shoushtari, Asal; Sheehan, Jason; Jones, David R.; Lu Weigo; Ruchala, Keneth; Olivera, Gustavo; Parnell, Donald; Larner, James L.; Benedict, Stanley H.; Read, Paul W.

    2010-01-01

    Stereotactic body radiation therapy (SBRT) treatments have high-dose gradients and even slight patient misalignment from the simulation to treatment could lead to target underdosing or organ at risk (OAR) overdosing. Daily real-time SBRT treatment planning could minimize the risk of geographic miss. As an initial step toward determining the clinical feasibility of developing real-time SBRT treatment planning, we determined the calculation time of helical TomoTherapy-based STAT radiation therapy (RT) treatment plans for simple liver, lung, and spine SBRT treatments to assess whether the planning process was fast enough for practical clinical implementation. Representative SBRT planning target volumes for hypothetical liver, peripheral lung, and thoracic spine lesions and adjacent OARs were contoured onto a planning computed tomography scan (CT) of an anthropomorphic phantom. Treatment plans were generated using both STAT RT 'full scatter' and conventional helical TomoTherapy 'beamlet' algorithms. Optimized plans were compared with respect to conformality index (CI), heterogeneity index (HI), and maximum dose to regional OARs to determine clinical equivalence and the number of required STAT RT optimization iterations and calculation times were determined. The liver and lung dosimetry for the STAT RT and standard planning algorithms were clinically and statistically equivalent. For the liver lesions, 'full scatter' and 'beamlet' algorithms showed a CI of 1.04 and 1.04 and HI of 1.03 and 1.03, respectively. For the lung lesions, 'full scatter' and 'beamlet' algorithms showed a CI of 1.05 and 1.03 and HI of 1.05and 1.05, respectively. For spine lesions, 'full scatter' and 'beamlet' algorithms showed a CI of 1.15 and 1.14 and HI of 1.22 and 1.14, respectively. There was no difference between treatment algorithms with respect to maximum doses to the OARs. The STAT RT iteration time with current treatment planning systems is 45 sec, and the treatment planning required 3

  2. Dosimetric comparison between conformational irradiation and helical tomo-therapy in supra-diaphragmatic Hodgkin disease in paediatrics; Comparaison dosimetrique entre l'irradiation conformationelle et la tomotherapie helicoidale dans la maladie de Hodgkin sus-diaphragmatique en pediatrie

    Energy Technology Data Exchange (ETDEWEB)

    Padovani, L.; Taright, N.; Muraracciole, X.; Nomikossof, N.; Capdeville, S.; Portal, T.; Cowen, D. [Assistance publique-hopitaux de Marseille (France)

    2011-10-15

    The authors report the comparison of dosimetry when using three-dimensional conformational radiotherapy or intensity-modulated conformational radiotherapy (IMRT) in the case of 13 children treated for a Hodgkin disease. The comparison is made in terms of previsional target volume (PTV) coverage and of doses received at the level of organs at risk. Coverage is almost the same for both techniques. Helical tomo-therapy allows the reduction of doses delivered to the heart, spine and lungs, including low doses (V5 and V10) while respecting an identical PTV coverage. This dose reduction could result in a reduction of toxicity on the long term, which is a major challenge for cured children. Short communication

  3. Modelling simple helically delivered dose distributions

    International Nuclear Information System (INIS)

    Fenwick, John D; Tome, Wolfgang A; Kissick, Michael W; Mackie, T Rock

    2005-01-01

    In a previous paper, we described quality assurance procedures for Hi-Art helical tomotherapy machines. Here, we develop further some ideas discussed briefly in that paper. Simple helically generated dose distributions are modelled, and relationships between these dose distributions and underlying characteristics of Hi-Art treatment systems are elucidated. In particular, we describe the dependence of dose levels along the central axis of a cylinder aligned coaxially with a Hi-Art machine on fan beam width, couch velocity and helical delivery lengths. The impact on these dose levels of angular variations in gantry speed or output per linear accelerator pulse is also explored

  4. Evaluation of two tomotherapy-based techniques for the delivery of whole-breast intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Gonzalez, Victor J.; Buchholz, Daniel J.; Langen, Katja M.; Olivera, Gustavo H.; Chauhan, Bhavin; Meeks, Sanford L.; Ruchala, Kenneth J.; Haimerl, Jason; Lu Weiguo; Kupelian, Patrick A.

    2006-01-01

    Purpose: To evaluate two different techniques for whole-breast treatments delivered using the Hi-ART II tomotherapy device. Methods and Materials: Tomotherapy uses the standard rotational helical delivery. Topotherapy uses a stationary gantry while delivering intensity-modulated treatments. CT scans from 5 breast cancer patients were used. The prescription dose was 50.4 Gy. Results: On average, 99% of the target volume received 95% of prescribed dose with either technique. If treatment times are restricted to less than 9 min, the average percentage ipsilateral lung receiving ≥20 Gy was 22% for tomotherapy vs. 10% for topotherapy. The ipsilateral lung receiving ≥50.4 Gy was 4 cc for tomotherapy vs. 27 cc for topotherapy. The percentage of left ventricle receiving ≥30 Gy was 14% with tomotherapy vs. 4% for topotherapy. The average doses to the contralateral breast and lung were 0.6 and 0.8 Gy, respectively, for tomotherapy vs. 0.4 and 0.3 Gy for topotherapy. Conclusions: Tomotherapy provides improved target dose homogeneity and conformality over topotherapy. If delivery times are restricted, topotherapy reduces the amount of heart and ipsilateral lung volumes receiving low doses. For whole-breast treatments, topotherapy is an efficient technique that achieves adequate target uniformity while maintaining low doses to sensitive structures

  5. Preliminary Retrospective Analysis of Daily Tomotherapy Output Constancy Checks Using Statistical Process Control.

    Science.gov (United States)

    Mezzenga, Emilio; D'Errico, Vincenzo; Sarnelli, Anna; Strigari, Lidia; Menghi, Enrico; Marcocci, Francesco; Bianchini, David; Benassi, Marcello

    2016-01-01

    The purpose of this study was to retrospectively evaluate the results from a Helical TomoTherapy Hi-Art treatment system relating to quality controls based on daily static and dynamic output checks using statistical process control methods. Individual value X-charts, exponentially weighted moving average charts, and process capability and acceptability indices were used to monitor the treatment system performance. Daily output values measured from January 2014 to January 2015 were considered. The results obtained showed that, although the process was in control, there was an out-of-control situation in the principal maintenance intervention for the treatment system. In particular, process capability indices showed a decreasing percentage of points in control which was, however, acceptable according to AAPM TG148 guidelines. Our findings underline the importance of restricting the acceptable range of daily output checks and suggest a future line of investigation for a detailed process control of daily output checks for the Helical TomoTherapy Hi-Art treatment system.

  6. Helical tomotherapy in patients with breast cancer and complex treatment volumes.

    Science.gov (United States)

    Cendales, Ricardo; Schiappacasse, Luis; Schnitman, Franco; García, Graciela; Marsiglia, Hugo

    2011-04-01

    To describe early clinical results of tomotherapy treatment in patients with breast cancer and complex treatment volumes. Ten patients were treated with tomotherapy between January 2009 and March 2010. Treatment planning objectives were to cover at least 95% of the planning target volume with the 95% isodose; to have a minimum dose of 90% and a maximum dose of 105%. All treatments included daily CT/megavoltage image guidance. Acute toxicity was recorded weekly. Six patients were treated because constraints were not accomplished for heart, lung or contralateral breast in a previous three-dimensional conformal plan; two for preexisting cardiac or pulmonary disease, and two more for bilateral breast irradiation. Treatment volumes included the whole breast in the majority of patients, as well as the supraclavicular and the internal mammary chain nodes when indicated. Most patients were older than 50 years, and had an early breast cancer, with positive oestrogen receptors, negative HER2 expression and a poorly differentiated, infiltrating ductal carcinoma. The majority of patients had received neoadjuvant chemotherapy associated to breast-conserving surgery and adjuvant hormonotherapy. Median homogeneity index was 1.09; median coverage index was 0.81. Median V20Gy and V10Gy for ipsilateral lung was 20% and 37.1% respectively. Median V25 and V35 for heart was 15% and 4% respectively. Median dose for contralateral breast was 7 Gy. Skin acute toxicity was grade 1 in 41.7% and grade 2 in 58.3%. Tomotherapy is a technique capable of delivering a well tolerated treatment with high homogeneity and coverage indexes and high capabilities for sparing the organs at risk in patients with anatomically complex breast cancer, bilateral breast cancer, indication for internal mammary chain node irradiation, cardiac toxicity derived from chemotherapy, or preexisting cardiac or pulmonary disease. Further studies are required to evaluate local control and late toxicity.

  7. The role of helical tomotherapy in the treatment of bone plasmacytoma.

    Science.gov (United States)

    Chargari, Cyrus; Hijal, Tarek; Bouscary, Didier; Caussa, Lucas; Dendale, Remi; Zefkili, Sofia; Fourquet, Alain; Kirova, Youlia M

    2012-01-01

    We evaluated the early clinical outcome of patients with solitary bone plasmacytoma (SP) or a solitary lesion of multiple myeloma (MM) treated with helical tomotherapy (HT) compared with 3D conformal radiotherapy (3D-CRT), in terms of target coverage and exposure of critical organs. Ten patients with SP and 3 patients with a solitary lesion of MM underwent radiation therapy (RT) delivered by HT, to a dose of 40 Gy in 20 fractions. Treatment planning was then performed with 3D-CRT and the dosimetric parameters of both techniques were compared. Patients were also assessed for response to treatment and acute toxicities. With a median follow-up of 13 months, 78% of patients with pain before RT had resolution of their symptoms. Coverage of target lesion was adequate with both techniques in 12 of 13 patients. Target coverage was significantly lower for HT (V(95%) = 98.55% vs. 97.15%; p = 0.04, for 3D-CRT and HT, respectively). Target overdoses were also lower with HT (V(105%) = 2.01% vs. 0.19%; p= 0.16), although nonsignificant. Finally, there were no significant differences in organs-at-risk irradiation between both techniques. The early treatment tolerance was excellent, with no toxicity higher than grade I. RT of SP and MM with a solitary lesion can be safely delivered with HT, with no major acute side effects and good symptomatic control. Finally, HT provides a dosimetry similar to that of 3D-CRT in terms of organs-at-risk sparing and target volume coverage. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  8. Comparing the quality of passively-scattered proton and photon tomotherapy plans for brain and head and neck disease sites

    International Nuclear Information System (INIS)

    Kainz, Kristofer; Firat, Selim; Wilson, J Frank; Schultz, Christopher; Siker, Malika; Wang, Andrew; Olson, Dan; Allen Li, X

    2015-01-01

    We compare the quality of photon IMRT (helical tomotherapy) with classic proton plans for brain, head and neck tumors, in terms of target dose uniformity and conformity along with organ-at-risk (OAR) sparing. Plans were created for twelve target volumes among eight cases. All patients were originally planned and treated using helical tomotherapy. Proton plans were generated using a passively-scattered beam model with a maximum range of 32 g cm −2 (225 MeV), range modulation in 0.5 g cm −2 increments and range compensators with 4.8 mm milling tool diameters. All proton plans were limited to two to four beams. Plan quality was compared using uniformity index (UI), conformation number (CN) and a EUD-based plan quality index (fEUD). For 11 of the 12 targets, UI was improved for the proton plan; on average, UI was 1.05 for protons versus 1.08 for tomotherapy. For 7 of the 12 targets, the tomotherapy plan exhibited more favorable CN. For proximal OARs, the improved dose conformity to the target volume from tomotherapy led to a lower maximum dose. For distal OARs, the maximum dose was much lower for proton plans. For 6 of the 8 cases, near-total avoidance for distal OARs provided by protons leads to improved fEUD. However, if distal OARs are excluded in the fEUD calculation, the proton plans exhibit better fEUD in only 3 of the 8 cases. The distal OAR sparing and target dose uniformity are generally better with passive-scatter proton planning than with photon tomotherapy; proton therapy may be preferred if the clinician deems those attributes critical. However, tomotherapy may serve equally as well as protons for cases where superior target dose conformity from tomotherapy leads to plan quality nearly identical to or better than protons and for cases where distal OAR sparing is not concerning. (paper)

  9. Image-guided intensity modulated radiotherapy with helical tomotherapy for postoperative treatment of high-risk oral cavity cancer

    Directory of Open Access Journals (Sweden)

    Chen Yu-Jen

    2011-01-01

    Full Text Available Abstract Background The aim of this study was to assess the treatment results and toxicity profiles of helical tomotherapy (HT for postoperative high-risk oral cavity cancer. Methods From December 6, 2006 through October 9, 2009, 19 postoperative high-risk oral cavity cancer patients were enrolled. All of the patients received HT with (84% or without (16% chemotherapy. Results The median follow-up time was 17 months. The 2-year overall survival, disease-free survival, locoregional control, and distant metastasis-free rates were 94%, 84%, 92%, and 94%, respectively. The package of overall treatment time > 13 wk, the interval between surgery and radiation ≤ 6 wk, and the overall treatment time of radiation ≤ 7 wk was 21%, 84%, and 79%, respectively. The percentage of grade 3 mucositis, dermatitis, and leucopenia was 42%, 5% and 5%, respectively. Conclusions HT achieved encouraging clinical outcomes for postoperative high-risk oral cavity cancer patients with high compliance. A long-term follow-up study is needed to confirm these preliminary findings.

  10. Feasibility and response of helical tomotherapy in patients with metastatic colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Ho [Dept. of Radiation Oncology, Catholic Kwandong University International St. Mary' s Hospital, Incheon (Korea, Republic of); Bae, Sun yun; Moon, Seong Kwon; Cho, Kwang Hwan; Shin, Eung Jin; Lee, Moon Sung; Ryu, Chang Beom; Ko, Bong Min; Yun, Ji Na [Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of)

    2015-12-15

    To investigate the treatment outcome and the toxicity of helical tomotherapy (HT) in patients with metastatic colorectal cancer (mCRC). We retrospectively reviewed 18 patients with 31 lesions from mCRC treated with HT between 2009 and 2013. The liver (9 lesions) and lymph nodes (9 lesions) were the most frequent sites. The planning target volume (PTV) ranged from 12 to 1,110 mL (median, 114 mL). The total doses ranged from 30 to 70 Gy in 10-30 fractions. When the alpha/beta value for the tumor was assumed to be 10 Gy for the biologically equivalent dose (BED), the total doses ranged from 39 to 119 Gy{sub 10} (median, 55 Gy{sub 10}). Nineteen lesions were treated with concurrent chemotherapy (CCRT). With a median follow-up time of 16 months, the median overall survival for 18 patients was 33 months. Eight lesions (26%) achieved complete response. The 1- and 3-year local progression free survival (LPFS) rates for 31 lesions were 45% and 34%, respectively. On univariate analysis, significant parameters influencing LPFS rates were chemotherapy response before HT, aim of HT, CCRT, PTV, BED, and adjuvant chemotherapy. On multivariate analysis, PTV < or =113 mL and BED >48 Gy{sub 10} were associated with a statistically significant improvement in LFPS. During HT, four patients experienced grade 3 hematologic toxicities, each of whom had also received CCRT. The current study demonstrates the efficacy and tolerability of HT for mCRC. To define optimal RT dose according to tumor size of mCRC, further study should be needed.

  11. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    International Nuclear Information System (INIS)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-01-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  12. A dosimetric comparison of tomotherapy and volumetric modulated arc therapy in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy.

    Science.gov (United States)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-02-01

    To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Tumor cell survival dependence on helical tomotherapy, continuous arc and segmented dose delivery

    International Nuclear Information System (INIS)

    Yang Wensha; Wang Li; Larner, James; Read, Paul; Benedict, Stan; Sheng Ke

    2009-01-01

    The temporal pattern of radiation delivery has been shown to influence the tumor cell survival fractions for the same radiation dose. To study the effect more specifically for state of the art rotational radiation delivery modalities, 2 Gy of radiation dose was delivered to H460 lung carcinoma, PC3 prostate cancer cells and MCF-7 breast tumor cells by helical tomotherapy (HT), seven-field LINAC (7F), and continuous dose delivery (CDD) over 2 min that simulates volumetric rotational arc therapy. Cell survival was measured by the clonogenic assay. The number of viable H460 cell colonies was 23.2 ± 14.4% and 27.7 ± 15.6% lower when irradiated by CDD compared with HT and 7F, respectively, and the corresponding values were 36.8 ± 18.9% and 35.3 ± 18.9% lower for MCF7 cells (p < 0.01). The survival of PC3 was also lower when irradiated by CDD than by HT or 7F but the difference was not as significant (p = 0.06 and 0.04, respectively). The higher survival fraction from HT delivery was unexpected because 90% of the 2 Gy was delivered in less than 1 min at a significantly higher dose rate than the other two delivery techniques. The results suggest that continuous dose delivery at a constant dose rate results in superior in vitro tumor cell killing compared with prolonged, segmented or variable dose rate delivery.

  14. Helical Tomotherapy Versus Single-Arc Intensity-Modulated Arc Therapy: A Collaborative Dosimetric Comparison Between Two Institutions

    International Nuclear Information System (INIS)

    Rong Yi; Tang, Grace; Welsh, James S.; Mohiuddin, Majid M.; Paliwal, Bhudatt; Yu, Cedric X.

    2011-01-01

    Purpose: Both helical tomotherapy (HT) and single-arc intensity-modulated arc therapy (IMAT) deliver radiation using rotational beams with multileaf collimators. We report a dual-institution study comparing dosimetric aspects of these two modalities. Methods and Materials: Eight patients each were selected from the University of Maryland (UMM) and the University of Wisconsin Cancer Center Riverview (UWR), for a total of 16 cases. Four cancer sites including brain, head and neck (HN), lung, and prostate were selected. Single-arc IMAT plans were generated at UMM using Varian RapidArc (RA), and HT plans were generated at UWR using Hi-Art II TomoTherapy. All 16 cases were planned based on the identical anatomic contours, prescriptions, and planning objectives. All plans were swapped for analysis at the same time after final approval. Dose indices for targets and critical organs were compared based on dose-volume histograms, the beam-on time, monitor units, and estimated leakage dose. After the disclosure of comparison results, replanning was done for both techniques to minimize diversity in optimization focus from different operators. Results: For the 16 cases compared, the average beam-on time was 1.4 minutes for RA and 4.8 minutes for HT plans. HT provided better target dose homogeneity (7.6% for RA and 4.2% for HT) with a lower maximum dose (110% for RA and 105% for HT). Dose conformation numbers were comparable, with RA being superior to HT (0.67 vs. 0.60). The doses to normal tissues using these two techniques were comparable, with HT showing lower doses for more critical structures. After planning comparison results were exchanged, both techniques demonstrated improvements in dose distributions or treatment delivery times. Conclusions: Both techniques created highly conformal plans that met or exceeded the planning goals. The delivery time and total monitor units were lower in RA than in HT plans, whereas HT provided higher target dose uniformity.

  15. Helical CT defecography

    International Nuclear Information System (INIS)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M.; Tornago, S.

    1999-01-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases [it

  16. SU-E-T-197: Helical Cranial-Spinal Treatments with a Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, J; Bernard, D; Liao, Y; Templeton, A; Turian, J; Chu, J [Rush University Medical Center, Chicago, IL (United States)

    2014-06-01

    Purpose: Craniospinal irradiation (CSI) of systemic disease requires a high level of beam intensity modulation to reduce dose to bone marrow and other critical structures. Current helical delivery machines can take 30 minutes or more of beam-on time to complete these treatments. This pilot study aims to test the feasibility of performing helical treatments with a conventional linear accelerator using longitudinal couch travel during multiple gantry revolutions. Methods: The VMAT optimization package of the Eclipse 10.0 treatment planning system was used to optimize pseudo-helical CSI plans of 5 clinical patient scans. Each gantry revolution was divided into three 120° arcs with each isocenter shifted longitudinally. Treatments requiring more than the maximum 10 arcs used multiple plans with each plan after the first being optimized including the dose of the others (Figure 1). The beam pitch was varied between 0.2 and 0.9 (couch speed 5- 20cm/revolution and field width of 22cm) and dose-volume histograms of critical organs were compared to tomotherapy plans. Results: Viable pseudo-helical plans were achieved using Eclipse. Decreasing the pitch from 0.9 to 0.2 lowered the maximum lens dose by 40%, the mean bone marrow dose by 2.1% and the maximum esophagus dose by 17.5%. (Figure 2). Linac-based helical plans showed dose results comparable to tomotherapy delivery for both target coverage and critical organ sparing, with the D50 of bone marrow and esophagus respectively 12% and 31% lower in the helical linear accelerator plan (Figure 3). Total mean beam-on time for the linear accelerator plan was 8.3 minutes, 54% faster than the tomotherapy average for the same plans. Conclusions: This pilot study has demonstrated the feasibility of planning pseudo-helical treatments for CSI targets using a conventional linac and dynamic couch movement, and supports the ongoing development of true helical optimization and delivery.

  17. Maximum likelihood as a common computational framework in tomotherapy

    International Nuclear Information System (INIS)

    Olivera, G.H.; Shepard, D.M.; Reckwerdt, P.J.; Ruchala, K.; Zachman, J.; Fitchard, E.E.; Mackie, T.R.

    1998-01-01

    Tomotherapy is a dose delivery technique using helical or axial intensity modulated beams. One of the strengths of the tomotherapy concept is that it can incorporate a number of processes into a single piece of equipment. These processes include treatment optimization planning, dose reconstruction and kilovoltage/megavoltage image reconstruction. A common computational technique that could be used for all of these processes would be very appealing. The maximum likelihood estimator, originally developed for emission tomography, can serve as a useful tool in imaging and radiotherapy. We believe that this approach can play an important role in the processes of optimization planning, dose reconstruction and kilovoltage and/or megavoltage image reconstruction. These processes involve computations that require comparable physical methods. They are also based on equivalent assumptions, and they have similar mathematical solutions. As a result, the maximum likelihood approach is able to provide a common framework for all three of these computational problems. We will demonstrate how maximum likelihood methods can be applied to optimization planning, dose reconstruction and megavoltage image reconstruction in tomotherapy. Results for planning optimization, dose reconstruction and megavoltage image reconstruction will be presented. Strengths and weaknesses of the methodology are analysed. Future directions for this work are also suggested. (author)

  18. Dose-volume histogram comparison between static 5-field IMRT with 18-MV X-rays and helical tomotherapy with 6-MV X-rays.

    Science.gov (United States)

    Hayashi, Akihiro; Shibamoto, Yuta; Hattori, Yukiko; Tamura, Takeshi; Iwabuchi, Michio; Otsuka, Shinya; Sugie, Chikao; Yanagi, Takeshi

    2015-03-01

    We treated prostate cancer patients with static 5-field intensity-modulated radiation therapy (IMRT) using linac 18-MV X-rays or tomotherapy with 6-MV X-rays. As X-ray energies differ, we hypothesized that 18-MV photon IMRT may be better for large patients and tomotherapy may be more suitable for small patients. Thus, we compared dose-volume parameters for the planning target volume (PTV) and organs at risk (OARs) in 59 patients with T1-3 N0M0 prostate cancer who had been treated using 5-field IMRT. For these same patients, tomotherapy plans were also prepared for comparison. In addition, plans of 18 patients who were actually treated with tomotherapy were analyzed. The evaluated parameters were homogeneity indicies and a conformity index for the PTVs, and D2 (dose received by 2% of the PTV in Gy), D98, Dmean and V10-70 Gy (%) for OARs. To evaluate differences by body size, patients with a known body mass index were grouped by that index ( 25 kg/m(2)). For the PTV, all parameters were higher in the tomotherapy plans compared with the 5-field IMRT plans. For the rectum, V10 Gy and V60 Gy were higher, whereas V20 Gy and V30 Gy were lower in the tomotherapy plans. For the bladder, all parameters were higher in the tomotherapy plans. However, both plans were considered clinically acceptable. Similar trends were observed in 18 patients treated with tomotherapy. Obvious trends were not observed for body size. Tomotherapy provides equivalent dose distributions for PTVs and OARs compared with 18-MV 5-field IMRT. Tomotherapy could be used as a substitute for high-energy photon IMRT for prostate cancer regardless of body size. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  19. Tomotherapy: IMRT and tomographic verification

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2000-01-01

    include MLC's and many clinics use them to replace 90% or more of the field-shaping requirements of conventional radiotherapy. Now, several academic centers are treating patients with IMRT using conventional MLC's to modulate the field. IMRT using conventional MLC's have the advantage that the patient is stationary during the treatment and the MLC's can be used in conventional practice. Nevertheless, tomotherapy using the Peacock system delivers the most conformal dose distributions of any commercial system to date. The biggest limitation with the both the NOMOS Peacock tomotherapy system and conventional MLC's for IMRT delivery is the lack of treatment verification. In conventional few-field radiotherapy one relied on portal images to determine if the patient was setup correctly and the beams were correctly positioned. With IMRT the image contrast is superimposed on the beam intensity variation. Conventional practice allowed for monitor unit calculation checks and point dosimeters placed on the patient's surface to verify that the treatment was properly delivered. With IMRT it is impossible to perform hand calculations of monitor units and dosimeters placed on the patient's surface are prone to error due to high gradients in the beam intensity. NOMOS has developed a verification phantom that allows multiple sheets of film to be placed in a light-tight box that is irradiated with the same beam pattern that is used to treat the patient. The optical density of the films are adjusted, normalized, and calibrated and then quantitatively compared with the dose calculated for the phantom delivery. However, this process is too laborious to be used for patient-specific QA. If IMRT becomes ubiquitous and it can be shown that IMRT is useful on most treatment sites then there is a need to design treatment units dedicated to IMRT delivery and verification. Helical tomotherapy is such a redesign. Helical tomotherapy is the delivery of a rotational fan beam while the patient is

  20. Toxic risk of stereotactic body radiotherapy and concurrent helical tomotherapy followed by erlotinib for non-small-cell lung cancer treatment - case report

    International Nuclear Information System (INIS)

    Hsieh, Chen-Hsi; Chen, Chun-Yi; Shueng, Pei-Wei; Chang, Hou-Tai; Lin, Shih-Chiang; Chen, Yu-Jen; Wang, Li-Ying; Hsieh, Yen-Ping; Chen, Chien-An; Chong, Ngot-Swan; Lin, Shoei Long

    2010-01-01

    Stereotactic body radiation therapy (SBRT) applied by helical tomotherapy (HT) is feasible for lung cancer in clinical. Using SBRT concurrently with erlotinib for non-small cell lung cancer (NSCLC) is not reported previously. A 77-year-old man with stage III NSCLC, received erlotinib 150 mg/day, combined with image-guided SBRT via HT. A total tumor dose of 54 Gy/9 fractions was delivered to the tumor bed. The tumor responded dramatically and the combined regimen was well tolerated. After concurrent erlotinib-SBRT, erlotinib was continued as maintenance therapy. The patient developed dyspnea three months after the combined therapy and radiation pneumonitis with interstitial lung disease was suspected. Combination SBRT, HT, and erlotinib therapy provided effective anti-tumor results. Nonetheless, the potential risks of enhanced adverse effects between radiation and erlotinib should be monitored closely, especially when SBRT is part of the regimen

  1. Xerostomia in patients treated for oropharyngeal carcinoma: comparing linear accelerator-based intensity-modulated radiation therapy with helical tomotherapy.

    Science.gov (United States)

    Fortin, Israël; Fortin, Bernard; Lambert, Louise; Clavel, Sébastien; Alizadeh, Moein; Filion, Edith J; Soulières, Denis; Bélair, Manon; Guertin, Louis; Nguyen-Tan, Phuc Felix

    2014-09-01

    In comparison to sliding-window intensity-modulated radiation therapy (sw-IMRT), we hypothesized that helical tomotherapy (HT) would achieve similar locoregional control and, at the same time, decrease the parotid gland dose, thus leading to a xerostomia reduction. The association between radiation techniques, mean parotid dose, and xerostomia incidence, was reviewed in 119 patients with advanced oropharyngeal carcinoma treated with concurrent chemoradiation using sw-IMRT (n = 59) or HT (n = 60). Ipsilateral and contralateral parotid mean doses were significantly lower for patients treated with HT versus sw-IMRT: 24 Gy versus 32 Gy ipsilaterally and 20 Gy versus 25 Gy contralaterally. The incidence of grade ≥2 xerostomia was significantly lower in the HT group than in the sw-IMRT group: 12% versus 78% at 6 months, 3% versus 51% at 12 months, and 0% versus 25% at 24 months. Total parotid mean dose xerostomia at 6, 12, and 24 months. This retrospective series suggests that using HT can better spare the parotid glands while respecting quantitative analysis of normal tissue effects in the clinic (QUANTEC)'s criteria. Copyright © 2013 Wiley Periodicals, Inc.

  2. SU-F-T-435: Helical Tomotherapy for Craniospinal Irradiation: What We Have Learned from a Multi-Institutional Study

    Energy Technology Data Exchange (ETDEWEB)

    Du, D; Kaprealian, T; Low, D; Qi, X [University of California Los Angeles, Los Angeles, CA (United States); Han, C [City of Hope National Medical Center, Los Angeles, CA (United States); Chen, J; Perez-Andujar, A [University of California San Francisco, Lafayette, CA (United States); Lee, B [University of California, Los Angeles, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To report cranio-spinal irradiation (CSI) planning experience, compare dosimetric quality and delivery efficiency with Tomotherapy from different institutions, and to investigate effect of planning parameters on plan quality and treatment time. Methods: Clinical helical tomotherapy IMRT plans for thirty-nine CSI cases from three academic institutions were retrospectively evaluated. The planning parameters: field width (FW), pitch, modulation factor (MF), and achieved dosimetric endpoints were cross-compared. A fraction-dose-delivery-timing index (FDTI), defined as treatment time per fraction dose per PTV length, was utilized to evaluate plan delivery efficiency. A lower FDTI indicates higher delivery efficiency. We studied the correlation between planning quality, treatment time and planning parameters by grouping the plans under specific planning parameters. Additionally, we created new plans using 5cm jaw for a subset of plans that used 2.5cm jaw to exam if treatment efficiency can be improved without sacrificing plan quality. Results: There were significant dosimetric differences for organ at risks (OARs) among different institutions (A,B,C). Using the lowest average MF (1.9±0.4) and 5cm field width, C had the highest lung, heart, kidney, liver mean doses and maximum doses for lens. Using the same field width of 5cm, but higher MF (2.6±0.6), B had lower doses to the OARs in the thorax and abdomen area. Most of A’s plans were planned with 2.5cm jaw, the plans yielded better PTV coverage, higher OAR doses and slightly shorter FDTI compared to institution B. The replanned 5cm jaw plans achieved comparable PTV coverage and OARs sparing, while saving up to 44.7% treatment time. Conclusion: Plan quality and delivery efficiency could vary significantly in CSI planning on Tomotheapy due to choice of different planning parameters. CSI plans using a 5cm jaw, with proper selection of pitch and MF, can achieve comparable/ better plan quality with shorter

  3. Feasibility of Helical Tomotherapy for Debulking Irradiation Before Stem Cell Transplantation in Malignant Lymphoma

    International Nuclear Information System (INIS)

    Chargari, Cyrus; Vernant, Jean-Paul; Tamburini, Jerome; Zefkili, Sofia; Fayolle, Maryse; Campana, Francois; Fourquet, Alain; Kirova, Youlia M.

    2011-01-01

    Purpose: Preliminary clinical experience has suggested that radiation therapy (RT) may be effectively incorporated into conditioning therapy before transplant for patients with refractory/relapsed malignant lymphoma. We investigated the feasibility of debulking selective lymph node irradiation before autologous and/or allogeneic stem cell transplantation (SCT) using helical tomotherapy (HT). Methods and Materials: Six consecutive patients with refractory malignant lymphoma were referred to our institution for salvage HT before SCT. All patients had been previously heavily treated but had bulky residual tumor despite chemotherapy (CT) intensification. Two patients had received previous radiation therapy. HT delivered 30-40 Gy in the involved fields (IF), using 6 MV photons, 2 Gy per daily fraction. Total duration of treatment was 28 to 35 days. Results: Using HT, doses to critical organs (heart, lungs, esophagu, and parotids) were significantly decreased and highly conformational irradiation could be delivered to all clinical target volumes. HT delivery was technically possible, even in patients with lesions extremely difficult to irradiate in other conditions or in patients with previous radiation therapy. No Grade 2 or higher toxicity occurred. Four months after the end of HT, 5 patients experienced complete clinical, radiologic, and metabolic response and were subsequently referred for SCT. Conclusions: By more effectively sparing critical organs, HT may contribute to improving the tolerance of debulking irradiation before allograft. Quality of life may be preserved, and doses to the heart may be decreased. This is particularly relevant in heavily treated patients who are at risk for subsequent heart disease. These preliminary results require further prospective assessment.

  4. Use of semiconductor diodes for dosimetry TomoTherapy Hi-Art unit; Utilizacion de diodos de semiconductor para la dosimetria de una unidad Tomotherapy Hi-Art

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Rodriguez, J.; Garcia Repiso, S.; Martin Rincon, C.; Ramos Pacho, J. A.; Verde Velasco, J. M.; Montes Fuentes, C.; Dena Espinel, E. de; Gomez Llorente, P. L.; Fernandez Bordes, M.

    2011-07-01

    The radiotherapy unit TIT-Art TomoTherapy allows the realization of intensity modulated treatments in a helical manner through design, consisting of a linear accelerator installed on a rotating gantry in combination with the longitudinal movement of the treatment table and a multi leaf collimator (MLC) binary. The acceptance tests include, among other things, the acquisition of a set of dosimetric data (profiles and PDD), for later comparison with a reference set of measures taken at the factory, called the gold standard. Being pre commissioning from the factory, the unit will be accepted provided that the measured data meet the gold standard within preset tolerances. The dosimetric equipment used in the test of acceptance is provided by the manufacturer and so far is done with water tank, camera, software electrometer and associate of Standard Imaging and marketed by TomoTherapy Inc. The objective of this study is to compare the measures obtained with a semiconductor diode with the gold standard. (Author)

  5. Measurement of dosimetric parameters for Hi-ART helical tomotherapy unit

    International Nuclear Information System (INIS)

    Wang Yunlai; Sha Xiangyou; Dai Xiangkun; Ma Lin; Feng Linchun; Qu Baolin

    2008-01-01

    Objective: To develop a measurement method of dosimetric parameters for Hi-ART tomotherapy unit. Methods: Percentage depth doses and beam profiles were measured using the dedicated mini water phantom, and compared to the results of 6 MV X-ray from Primus accelerator. Following the AAPM TG51 protocol, absolute dose calibration was carried out under SSD of 8.5 cm at depth of 1.5 cm for field of 5 cm x 40 cm. The output linearity and reproducibility were evaluated. The output variation with the gantry rotation was also investigated using 0.6 cm 3 ion chamber in cylindrical perplex phantom and on-board MVCT detectors. Leaf fluence output factors were quantified for the leaf of interest and its adjacent leaves. Results: The buildup depth was around 1.0 cm. The PDD values at 10 cm for Hi-ART and Primus were 59.7% and 64.7%, respectively. Varying with the field width, the lateral and longitudinal beam profiles were not so homogeneous as the Primus fields. The measured dose rate was 848.38 cGy/min. The fitted linear function between the readings of dosimeter and the irradiated time was R(nC) =-0.017 + 0.256· t(sec), with a relative coefficient of 0.999. The maximum deviation and standard deviation of output were 1.6% and less than 0.5%; The maximum deviation and standard deviation of output changed by gantry angle were 1.1% and 0.5%, respectively. Leaf fluence output factors did not increase significantly when leaves were opened beyond the two adjacent leaves. Conclusions: Hi-ART Tomotherapy unit has a very high dose output and inhomogeneous beam profiles owing to its special design of the treatment head. This may be useful in dose calculation and treatment delivery. (authors)

  6. Cerebrospinal tomo-therapy; Tomotherapie cerebrospinale

    Energy Technology Data Exchange (ETDEWEB)

    Fumagalli, I.; Coche-Dequeant, B.; Lacornerie, T.; Reynaert, N.; Lartigau, E. [Centre Oscar-Lambret, 59 - Lille (France)

    2010-10-15

    The authors report the study of the feasibility of a cerebrospinal tomo-therapy, of the protection of organs at risk, and of tolerance. Nine patients have been treated, one with a bi-fractionated irradiation and the others with a conventional fractionation. Seven had chemotherapy before radiotherapy, and two had intensification with self-grafting of stem cells. The dose constraints and the planning target volume (PTV) differed with respect to the treated organ (kidney, lung, thyroid, parotid, hypophysis). The tolerance was good. It appears that cerebrospinal tomo-therapy results in a better comfort for the patient and an easier treatment plan with a good dose homogeneity. Short communication

  7. Intra-fraction motion of the prostate during treatment with helical tomotherapy

    International Nuclear Information System (INIS)

    Thomas, Simon J.; Ashburner, Mark; Tudor, George Samuel J.; Treeby, Jo; Dean, June; Routsis, Donna; Rimmer, Yvonne L.; Russell, Simon G.; Burnet, Neil G.

    2013-01-01

    Background and purpose: To measure the geometric uncertainty resulting from intra-fraction motion and intra-observer image matching, for patients having image-guided prostate radiotherapy on TomoTherapy. Material and methods: All patients had already been selected for prostate radiotherapy on TomoTherapy, with daily MV-CT imaging. The study involved performing an additional MV-CT image at the end of treatment, on 5 occasions during the course of 37 treatments. 54 patients were recruited to the study. A new formula was derived to calculate the PTV margin for intra-fraction motion. Results: The mean values of the intra-fraction differences were 0.0 mm, 0.5 mm, 0.5 mm and 0.0° for LR, SI, AP and roll, respectively. The corresponding standard deviations were 1.1 mm, 0.8 mm, 0.8 mm and 0.6° for systematic uncertainties (Σ), 1.3 mm, 2.0 mm, 2.2 mm and 0.3° for random uncertainties (σ). This intra-fraction motion requires margins of 2.2 mm in LR, 2.1 mm in SI and 2.1 mm in AP directions. Inclusion of estimates of the effect of rotations and matching errors increases these margins to approximately 4 mm in LR and 5 mm in SI and AP directions. Conclusions: A new margin recipe has been developed to calculate margins for intra-fraction motion. This recipe is applicable to any measurement technique that is based on the difference between images taken before and after treatment

  8. Toxic risk of stereotactic body radiotherapy and concurrent helical tomotherapy followed by erlotinib for non-small-cell lung cancer treatment - case report

    Directory of Open Access Journals (Sweden)

    Chen Chien-An

    2010-12-01

    Full Text Available Abstract Background Stereotactic body radiation therapy (SBRT applied by helical tomotherapy (HT is feasible for lung cancer in clinical. Using SBRT concurrently with erlotinib for non-small cell lung cancer (NSCLC is not reported previously. Case Presentation A 77-year-old man with stage III NSCLC, received erlotinib 150 mg/day, combined with image-guided SBRT via HT. A total tumor dose of 54 Gy/9 fractions was delivered to the tumor bed. The tumor responded dramatically and the combined regimen was well tolerated. After concurrent erlotinib-SBRT, erlotinib was continued as maintenance therapy. The patient developed dyspnea three months after the combined therapy and radiation pneumonitis with interstitial lung disease was suspected. Conclusions Combination SBRT, HT, and erlotinib therapy provided effective anti-tumor results. Nonetheless, the potential risks of enhanced adverse effects between radiation and erlotinib should be monitored closely, especially when SBRT is part of the regimen.

  9. Dynamic evaluation of pelvic floor reconstructive surgery using radiopaque meshes and three-dimensional helical CT

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2010-04-01

    Full Text Available PURPOSE: This prospective study was performed to achieve visualization of the reestablishment of anatomy after reconstructive surgery in the different pelvic compartments with non-absorbable radiopaque meshes, providing valuable anatomic information for surgeons implanting meshes. MATERIALS AND METHODS: A total of 30 female patients with stress urinary incontinence (SUI, anterior and posterior vaginal wall prolapse, or both underwent surgical repair using radiopaque meshes after written informed consent. Patients with SUI underwent five different surgeries. Patients with anterior vaginal prolapse underwent a procedure using a combined pre-pubic and transobturator mesh, and those with posterior vaginal prolapse underwent posterior slingplasty. Three-dimensional reconstruction using helical CT was performed four weeks postoperatively. RESULTS: In all cases, the mesh was clearly visualized. Transobturator slings were shown at the midurethra, and the anchoring tails perforated the obturator foramen at the safety region. Mini-slings were in the proper place, and computed angiography revealed that the anchoring system was away from the obturator vessels. In patients undergoing procedure for anterior vaginal prolapse, both pre-pubic armpit and obturator slings were clearly seen and the mesh was in the proper position, supporting the bladder base and occluding the distal part of the urogenital hiatus. Transcoccygeal sacropexy revealed indirectly a well-supported "neo rectovaginal fascia" and the anchoring tails at the level of ischial spines. CONCLUSION: Three-dimensional helical tomography images of the female pelvis using radiopaque meshes have a potential role in improving our understanding of pelvic floor reconstructive surgeries. These radiopaque meshes might be the basis of a new investigative methodology.

  10. Use of semiconductor diodes for dosimetry TomoTherapy Hi-Art unit

    International Nuclear Information System (INIS)

    Hernandez Rodriguez, J.; Garcia Repiso, S.; Martin Rincon, C.; Ramos Pacho, J. A.; Verde Velasco, J. M.; Montes Fuentes, C.; Dena Espinel, E. de; Gomez Llorente, P. L.; Fernandez Bordes, M.

    2011-01-01

    The radiotherapy unit TIT-Art TomoTherapy allows the realization of intensity modulated treatments in a helical manner through design, consisting of a linear accelerator installed on a rotating gantry in combination with the longitudinal movement of the treatment table and a multi leaf collimator (MLC) binary. The acceptance tests include, among other things, the acquisition of a set of dosimetric data (profiles and PDD), for later comparison with a reference set of measures taken at the factory, called the gold standard. Being pre commissioning from the factory, the unit will be accepted provided that the measured data meet the gold standard within preset tolerances. The dosimetric equipment used in the test of acceptance is provided by the manufacturer and so far is done with water tank, camera, software electrometer and associate of Standard Imaging and marketed by TomoTherapy Inc. The objective of this study is to compare the measures obtained with a semiconductor diode with the gold standard. (Author)

  11. Measurement and correction of leaf open times in helical tomotherapy

    International Nuclear Information System (INIS)

    Sevillano, David; Mínguez, Cristina; Sánchez, Alicia; Sánchez-Reyes, Alberto

    2012-01-01

    Purpose: The binary multileaf collimator (MLC) is one of the most important components in helical tomotherapy (HT), as it modulates the dose delivered to the patient. However, methods to ensure MLC quality in HT treatments are lacking. The authors obtained data on the performance of the MLC in treatments administered in their department in order to assess possible delivery errors due to the MLC. Correction methods based on their data are proposed. Methods: Twenty sinograms from treatments delivered using both of the authors HT systems were measured and analyzed by recording the fluence collected by the imaging detector. Planned and actual sinograms were compared using distributions of leaf open time (LOT) errors, as well as differences in fluence reconstructed at each of the 51 projections into which the treatment planning system divides each rotation for optimization purposes. They proposed and applied a method based on individual leaf error correction and the increase in projection time to prevent latency effects when LOT is close to projection time. In order to analyze the dosimetric impact of the corrections, inphantom measurements were made for four corrected treatments. Results: The LOTs measured were consistent with those planned. Most of the mean errors in LOT distributions were within 1 ms with standard deviations of over 4 ms. Reconstructed fluences showed good results, with over 90% of points passing the 3% criterion, except in treatments with a short mean LOT, where the percentage of passing points was as low as 66%. Individual leaf errors were as long as 4 ms in some cases. Corrected sinograms improved error distribution, with standard deviations of over 3 ms and increased percentages of points passing 3% in the fluence per angle analysis, especially in treatments with a short mean LOT and those that were more subject to latency effects. The minimum percentage of points within 3% increased to 86%. In-phantom measurements of the corrected treatments

  12. Measurement and correction of leaf open times in helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sevillano, David; Minguez, Cristina; Sanchez, Alicia; Sanchez-Reyes, Alberto [Department of Medical Physics, Tomotherapy Unit, Grupo IMO, Madrid 28010 (Spain)

    2012-11-15

    Purpose: The binary multileaf collimator (MLC) is one of the most important components in helical tomotherapy (HT), as it modulates the dose delivered to the patient. However, methods to ensure MLC quality in HT treatments are lacking. The authors obtained data on the performance of the MLC in treatments administered in their department in order to assess possible delivery errors due to the MLC. Correction methods based on their data are proposed. Methods: Twenty sinograms from treatments delivered using both of the authors HT systems were measured and analyzed by recording the fluence collected by the imaging detector. Planned and actual sinograms were compared using distributions of leaf open time (LOT) errors, as well as differences in fluence reconstructed at each of the 51 projections into which the treatment planning system divides each rotation for optimization purposes. They proposed and applied a method based on individual leaf error correction and the increase in projection time to prevent latency effects when LOT is close to projection time. In order to analyze the dosimetric impact of the corrections, inphantom measurements were made for four corrected treatments. Results: The LOTs measured were consistent with those planned. Most of the mean errors in LOT distributions were within 1 ms with standard deviations of over 4 ms. Reconstructed fluences showed good results, with over 90% of points passing the 3% criterion, except in treatments with a short mean LOT, where the percentage of passing points was as low as 66%. Individual leaf errors were as long as 4 ms in some cases. Corrected sinograms improved error distribution, with standard deviations of over 3 ms and increased percentages of points passing 3% in the fluence per angle analysis, especially in treatments with a short mean LOT and those that were more subject to latency effects. The minimum percentage of points within 3% increased to 86%. In-phantom measurements of the corrected treatments

  13. Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry Study

    International Nuclear Information System (INIS)

    Capelle, Lisa; Warkentin, Heather; MacKenzie, Marc; Joseph, Kurian; Gabos, Zsolt; Pervez, Nadeem; Tankel, Keith; Chafe, Susan; Amanie, John; Ghosh, Sunita; Parliament, Matthew; Abdulkarim, Bassam

    2012-01-01

    Purpose: We investigated whether treatment-planning system (TPS)-calculated dose accurately reflects skin dose received for patients receiving adjuvant breast radiotherapy (RT) with standard three-dimensional conformal RT (3D-CRT) or skin-sparing helical tomotherapy (HT). Methods and Materials: Fifty patients enrolled in a randomized controlled trial investigating acute skin toxicity from adjuvant breast RT with 3D-CRT compared to skin-sparing HT, where a 5-mm strip of ipsilateral breast skin was spared. Thermoluminescent dosimetry or optically stimulated luminescence measurements were made in multiple locations and were compared to TPS-calculated doses. Skin dosimetric parameters and acute skin toxicity were recorded in these patients. Results: With HT there was a significant correlation between calculated and measured dose in the medial and lateral ipsilateral breast (r = 0.67, P V50 (1.4% vs 5.9%, respectively; P=.001) but higher skin V40 and skin V30 (71.7% vs 64.0%, P=.02; and 99.0% vs 93.8%, P=.001, respectively) than 3D-CRT plans. Conclusion: The 3D-CRT TPS more accurately reflected skin dose than the HT TPS, which tended to overestimate dose received by 14% in patients receiving adjuvant breast RT.

  14. A technique for adaptive image-guided helical tomotherapy for lung cancer

    International Nuclear Information System (INIS)

    Ramsey, Chester R.; Langen, Katja M.; Kupelian, Patrick A.; Scaperoth, Daniel D.; Meeks, Sanford L.; Mahan, Stephen L.; Seibert, Rebecca M.

    2006-01-01

    Purpose: The gross tumor volume (GTV) for many lung cancer patients can decrease during the course of radiation therapy. As the tumor reduces in size during treatment, the margin added around the GTV effectively becomes larger, which can result in the excessive irradiation of normal lung tissue. The specific goal of this study is to evaluate the feasibility of using image-guided adaptive radiation therapy to adjust the planning target volume weekly based on the previous week's CT image sets that were used for image-guided patient setup. Methods and Materials: Megavoltage computed tomography (MVCT) images of the GTV were acquired daily on a helical tomotherapy system. These images were used to position the patient and to measure reduction in GTV volume. A planning study was conducted to determine the amount of lung-sparing that could have been achieved if adaptive therapy had been used. Treatment plans were created in which the target volumes were reduced after tumor reduction was measured. Results: A total of 158 MVCT imaging sessions were performed on 7 lung patients. The GTV was reduced by 60-80% during the course of treatment. The tumor reduction in the first 60 days of treatment can be modeled using the second-order polynomial R 0.0002t 2 - 0.0219t + 1.0, where R is the percent reduction in GTV, and t is the number of elapsed days. Based on these treatment planning studies, the absolute volume of ipsilateral lung receiving 20 Gy can be reduced between 17% and 23% (21% mean) by adapting the treatment delivery. The benefits of adaptive therapy are the greatest for tumor volumes ≥25 cm 3 and are directly dependent on GTV reduction during treatment. Conclusions: Megavoltage CT-based image guidance can be used to position lung cancer patients daily. This has the potential to decrease margins associated with daily setup error. Furthermore, the adaptive therapy technique described in this article can decrease the volume of healthy lung tissue receiving above 20 Gy

  15. Results of a two-year quality control program for a helical tomotherapy unit

    International Nuclear Information System (INIS)

    Broggi, Sara; Mauro Cattaneo, Giovanni; Molinelli, Silvia; Maggiulli, Eleonora; Del Vecchio, Antonella; Longobardi, Barbara; Perna, Lucia; Fazio, Ferruccio; Calandrino, Riccardo

    2008-01-01

    Background and purpose: Image-guided helical tomotherapy (HT) is a new modality for delivering intensity modulated radiation therapy (IMRT) with helical irradiation: the slip ring continuously rotates while the couch moves into the bore. The radiation source (Linac, 6 MV) is collimated into a fan beam and modulated by means of a binary multileaf collimator (MLC). A xenon detector array, opposite the radiation source, allows a megavoltage-CT (MVCT) acquisition of patient images for set-up verification. The aim of this paper is to report the results of a two-year quality control (QC) program for the physical and dosimetric characterization of an HT unit installed at our Institute and clinically activated in November 2004, in order to monitor and verify the stability and the reliability of this promising radiation treatment unit. Materials and methods: Conventional Linac acceptance protocols (ATP) and QC protocols were adapted to HT with the addition of specific items reflecting important differences between the two irradiation modalities. QC tests can be summarized as: (a) mechanical and geometrical characterization of the system's components: evaluation of alignment among radiation source-gantry rotation plan-jaws-MLC-MVCT; (b) treatment beam configuration in static condition: depth dose curves (PDD) and profiles, output factors, output reproducibility and linearity; (c) dynamic component characterization: accuracy and reproducibility of MLC positioning; rotational output reproducibility and linearity, leaf latency, couch movement constancy; (d) gantry-couch and MLC-gantry synchronization; and (e) MVCT image quality. Peculiar periodicity specific tolerance and action levels were defined. Ionization chambers (Exradin A1SL 0.056 cc), films (XOmat-V/EDR2), water and solid water phantoms were used to perform quality assurance measurements. Results: Over a two-year period the final average output variation after possible beam output adjustment was -0.2 ± 1% for the

  16. A dosimetric selectivity intercomparison of HDR brachytherapy, IMRT and helical tomotherapy in prostate cancer radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hermesse, Johanne; Biver, Sylvie; Jansen, Nicolas; Coucke, Philippe [Dept. of Radiation Oncology, Liege Univ. Hospital (Belgium); Lenaerts, Eric [Dept. of Medical Physics, Liege Univ. Hospital (Belgium); De Patoul, Nathalie; Vynckier, Stefaan [Dept. of Medical Physics, St Luc Univ. Hospital, Brussels (Belgium); Scalliet, Pierre [Dept. of Radiation Oncology, St Luc Univ. Hospital, Brussels (Belgium); Nickers, Philippe [Dept. of Radiation Oncology, Oscar Lambret Center, Lille (France)

    2009-11-15

    Background and purpose: dose escalation in order to improve the biochemical control in prostate cancer requires the application of irradiation techniques with high conformality. The dosimetric selectivity of three radiation modalities is compared: high-dose-rate brachytherapy (HDR-BT), intensity-modulated radiation radiotherapy (IMRT), and helical tomotherapy (HT). Patients and methods: ten patients with prostate adenocarcinoma treated by a 10-Gy HDR-BT boost after external-beam radiotherapy were investigated. For each patient, HDR-BT, IMRT and HT theoretical treatment plans were realized using common contour sets. A 10-Gy dose was prescribed to the planning target volume (PTV). The PTVs and critical organs' dose-volume histograms obtained were compared using Student's t-test. Results: HDR-BT delivers spontaneously higher mean doses to the PTV with smaller cold spots compared to IMRT and HT. 33% of the rectal volume received a mean HDR-BT dose of 3.86 {+-} 0.3 Gy in comparison with a mean IMRT dose of 6.57 {+-} 0.68 Gy and a mean HT dose of 5.58 {+-} 0.71 Gy (p < 0.0001). HDR-BT also enables to better spare the bladder. The hot spots inside the urethra are greater with HDR-BT. The volume of healthy tissue receiving 10% of the prescribed dose is reduced at least by a factor of 8 with HDR-BT (p < 0.0001). Conclusion: HDR-BT offers better conformality in comparison with HT and IMRT and reduces the volume of healthy tissue receiving a low dose. (orig.)

  17. Image Guided Hypofractionated Radiotherapy by Helical Tomotherapy for Prostate Carcinoma: Toxicity and Impact on Nadir PSA

    Directory of Open Access Journals (Sweden)

    Salvina Barra

    2014-01-01

    Full Text Available Aim. To evaluate the toxicity of a hypofractionated schedule for primary radiotherapy (RT of prostate cancer as well as the value of the nadir PSA (nPSA and time to nadir PSA (tnPSA as surrogate efficacy of treatment. Material and Methods. Eighty patients underwent hypofractionated schedule by Helical Tomotherapy (HT. A dose of 70.2 Gy was administered in 27 daily fractions of 2.6 Gy. Acute and late toxicities were graded on the RTOG/EORTC scales. The nPSA and the tnPSA for patients treated with exclusive RT were compared to an equal cohort of 20 patients treated with conventional fractionation and standard conformal radiotherapy. Results. Most of patients (83% did not develop acute gastrointestinal (GI toxicity and 50% did not present genitourinary (GU toxicity. After a median follow-up of 36 months only grade 1 of GU and GI was reported in 6 and 3 patients as late toxicity. Average tnPSA was 30 months. The median value of nPSA after exclusive RT with HT was 0.28 ng/mL and was significantly lower than the median nPSA (0.67 ng/mL of the conventionally treated cohort (P=0.02. Conclusions. Hypofractionated RT schedule with HT for prostate cancer treatment reports very low toxicity and reaches a low level of nPSA that might correlate with good outcomes.

  18. An automatic dose verification system for adaptive radiotherapy for helical tomotherapy

    International Nuclear Information System (INIS)

    Mo, Xiaohu; Chen, Mingli; Parnell, Donald; Olivera, Gustavo; Galmarini, Daniel; Lu, Weiguo

    2014-01-01

    Purpose: During a typical 5-7 week treatment of external beam radiotherapy, there are potential differences between planned patient's anatomy and positioning, such as patient weight loss, or treatment setup. The discrepancies between planned and delivered doses resulting from these differences could be significant, especially in IMRT where dose distributions tightly conforms to target volumes while avoiding organs-at-risk. We developed an automatic system to monitor delivered dose using daily imaging. Methods: For each treatment, a merged image is generated by registering the daily pre-treatment setup image and planning CT using treatment position information extracted from the Tomotherapy archive. The treatment dose is then computed on this merged image using our in-house convolution-superposition based dose calculator implemented on GPU. The deformation field between merged and planning CT is computed using the Morphon algorithm. The planning structures and treatment doses are subsequently warped for analysis and dose accumulation. All results are saved in DICOM format with private tags and organized in a database. Due to the overwhelming amount of information generated, a customizable tolerance system is used to flag potential treatment errors or significant anatomical changes. A web-based system and a DICOM-RT viewer were developed for reporting and reviewing the results. Results: More than 30 patients were analysed retrospectively. Our in-house dose calculator passed 97% gamma test evaluated with 2% dose difference and 2mm distance-to-agreement compared with Tomotherapy calculated dose, which is considered sufficient for adaptive radiotherapy purposes. Evaluation of the deformable registration through visual inspection showed acceptable and consistent results, except for cases with large or unrealistic deformation. Our automatic flagging system was able to catch significant patient setup errors or anatomical changes. Conclusions: We developed an automatic

  19. Development of a software tool for the management of quality control in a helical tomotherapy unit; Desarrollo de una herramienta de software para la gestion integral del control de calidad en una unidad de tomoterapia helicoidal

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Repiso, S.; Hernandez Rodriguez, J.; Martin Rincon, C.; Ramos Pacho, J. A.; Verde Velasco, J. M.; Delgado Aparacio, J. M.; Perez Alvarez, M. e.; Gomez Gonzalez, N.; Cons Perez, V.; Saez Beltran, M.

    2013-07-01

    The large amount of data and information that is managed in units of external radiotherapy quality control tests makes necessary the use of tools that facilitate, on the one hand, the management of measures and results in real time, and on other tasks of management, file, query and reporting of stored data. This paper presents an application of software of own development which is used for the integral management of the helical TomoTherapy unit in the aspects related to the roles and responsibilities of the hospital Radiophysics. (Author)

  20. A method for testing the performance and the accuracy of the binary MLC used in helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lissner, Steffen; Schubert, Kai; Klueter, Sebastian; Oetzel, Dieter; Debus, Juergen [University Hospital Heidelberg (Germany). Dept. of Radiation Oncology

    2013-08-01

    During a helical tomotherapy a binary MLC is used for fluence modulation. The 64 pneumatically driven leaves of the MLC are either completely open or closed. Th e fast and frequent leaf movements result in a high demand of accuracy and stability of the MLC. This article is based on the analytical investigation of the accuracy and the stability of the MLC. Different patterns of MLC movements were generated to investigate the characteristics of the MLC. One of the considered aspects contains the friction between the leaves. The influence of variations of the compressed air on the MLC was also explored. The integrated MVCT detector of the tomotherapy system deposits the treatment data in a matrix. The detector is triggered with the linear accelerator, which is pulsed by 300Hz. The data matrix is available after the treatment. An IDL (Interactive Data Language) routine was programmed in order to analyse the matrix. The points of time, at which the leaves open (POT), and the period, in which the leaves stay open (LOT), were measured and compared with the desired values. That procedure has been repeated several times a week for approximately 6 months to investigate the stability of the MLC. Relative deviations of the LOT from -0.4% to -5.4% were measured. The friction between the leaves had no significant influence on the LOT. The available compressed air, that is used to move the leaves, depends on the number of moving leaves and also on the previous movements of the MLC. Variations of the compressed air resulted in deviations of the LOT from -1.8% to -3.7%. The measured POT deviates from the programmed POT up to -18.4ms {+-} 0.7ms. This maximal deviation correlates with a shift of the gantry angle of 0.52 which is negligible. The MLC has shown a stable behaviour over the 6 months. A separate consideration of the leaves showed no higher standard deviation of the LOT than {+-} 0.7ms during the investigated time. The variation between the different leaves is much higher

  1. A method for testing the performance and the accuracy of the binary MLC used in helical tomotherapy

    International Nuclear Information System (INIS)

    Lissner, Steffen; Schubert, Kai; Klueter, Sebastian; Oetzel, Dieter; Debus, Juergen

    2013-01-01

    During a helical tomotherapy a binary MLC is used for fluence modulation. The 64 pneumatically driven leaves of the MLC are either completely open or closed. Th e fast and frequent leaf movements result in a high demand of accuracy and stability of the MLC. This article is based on the analytical investigation of the accuracy and the stability of the MLC. Different patterns of MLC movements were generated to investigate the characteristics of the MLC. One of the considered aspects contains the friction between the leaves. The influence of variations of the compressed air on the MLC was also explored. The integrated MVCT detector of the tomotherapy system deposits the treatment data in a matrix. The detector is triggered with the linear accelerator, which is pulsed by 300Hz. The data matrix is available after the treatment. An IDL (Interactive Data Language) routine was programmed in order to analyse the matrix. The points of time, at which the leaves open (POT), and the period, in which the leaves stay open (LOT), were measured and compared with the desired values. That procedure has been repeated several times a week for approximately 6 months to investigate the stability of the MLC. Relative deviations of the LOT from -0.4% to -5.4% were measured. The friction between the leaves had no significant influence on the LOT. The available compressed air, that is used to move the leaves, depends on the number of moving leaves and also on the previous movements of the MLC. Variations of the compressed air resulted in deviations of the LOT from -1.8% to -3.7%. The measured POT deviates from the programmed POT up to -18.4ms ± 0.7ms. This maximal deviation correlates with a shift of the gantry angle of 0.52 which is negligible. The MLC has shown a stable behaviour over the 6 months. A separate consideration of the leaves showed no higher standard deviation of the LOT than ± 0.7ms during the investigated time. The variation between the different leaves is much higher than

  2. TU-H-BRC-07: Therapeutic Benefit in Spatially Fractionated Radiotherapy (GRID) Using Helical Tomotherapy

    International Nuclear Information System (INIS)

    Narayanasamy, G; Zhang, X; Paudel, N; Morrill, S; Maraboyina, S; Peacock, L; Penagaricano, J; Meigooni, A; Liang, X

    2016-01-01

    Purpose: The aim of this project is to study the therapeutic ratio (TR) for helical Tomotherapy (HT) based spatially fractionated radiotherapy (GRID). Estimation of TR was based on the linear-quadratic cell survival model by comparing the normal cell survival in a HT GRID to that of a uniform dose delivery in an open-field for the same tumor survival. Methods: HT GRID plan was generated using a patient specific virtual GRID block pattern of non-divergent, cylinder shaped holes using MLCs. TR was defined as the ratio of normal tissue surviving fraction (SF) under HT GRID irradiation to an open field irradiation with an equivalent dose that result in the same tumor cell SF. The ratio was estimated from DVH data on ten patient plans with deep seated, bulky tumor approved by the treating radiation oncologist. Dependence of the TR values on radio-sensitivity of the tumor cells and prescription dose were also analyzed. Results: The mean ± standard deviation (SD) of TR was 4.0±0.7 (range: 3.1 to 5.5) for the 10 patients with single fraction dose of 20 Gy and tumor cell SF of 0.5 at 2 Gy. In addition, mean±SD of TR = 1±0.1 and 18.0±5.1 were found for tumor with SF of 0.3 and 0.7, respectively. Reducing the prescription dose to 15 and 10 Gy lowered the TR to 2.0±0.2 and 1.2±0.04 for a tumor cell SF of 0.5 at 2 Gy. In this study, the SF of normal cells was assumed to be 0.5 at 2 Gy. Conclusion: HT GRID displayed a significant therapeutic advantage over uniform dose from an open field irradiation. TR increases with the radioresistance of the tumor cells and with prescription dose.

  3. Prostate contouring uncertainty in megavoltage computed tomography images acquired with a helical tomotherapy unit during image-guided radiation therapy

    International Nuclear Information System (INIS)

    Song, William Y.; Chiu, Bernard; Bauman, Glenn S.; Lock, Michael; Rodrigues, George; Ash, Robert; Lewis, Craig; Fenster, Aaron; Battista, Jerry J.; Van Dyk, Jake

    2006-01-01

    Purpose: To evaluate the image-guidance capabilities of megavoltage computed tomography (MVCT), this article compares the interobserver and intraobserver contouring uncertainty in kilovoltage computed tomography (KVCT) used for radiotherapy planning with MVCT acquired with helical tomotherapy. Methods and Materials: Five prostate-cancer patients were evaluated. Each patient underwent a KVCT and an MVCT study, a total of 10 CT studies. For interobserver variability analysis, four radiation oncologists, one physicist, and two radiation therapists (seven observers in total) contoured the prostate and seminal vesicles (SV) in the 10 studies. The intraobserver variability was assessed by asking all observers to repeat the contouring of 1 patient's KVCT and MVCT studies. Quantitative analysis of contour variations was performed by use of volumes and radial distances. Results: The interobserver and intraobserver contouring uncertainty was larger in MVCT compared with KVCT. Observers consistently segmented larger volumes on MVCT where the ratio of average prostate and SV volumes was 1.1 and 1.2, respectively. On average (interobserver and intraobserver), the local delineation variability, in terms of standard deviations [Δσ = √(σ 2 MVCT - σ 2 KVCT )], increased by 0.32 cm from KVCT to MVCT. Conclusions: Although MVCT was inferior to KVCT for prostate delineation, the application of MVCT in prostate radiotherapy remains useful

  4. Preliminary analysis of risk factors for late rectal toxicity after helical tomotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Tomita, Natsuo; Soga, Norihito; Ogura, Yuji

    2013-01-01

    The purpose of this study is to examine risk factors for late rectal toxicity for localized prostate cancer patients treated with helical tomotherapy (HT). The patient cohort of this retrospective study was composed of 241 patients treated with HT and followed up regularly. Toxicity levels were scored according to the Radiation Therapy Oncology Group grading scale. The clinical and dosimetric potential factors increasing the risk of late rectal toxicity, such as age, diabetes, anticoagulants, prior abdominal surgery, prescribed dose, maximum dose of the rectum, and the percentage of the rectum covered by 70 Gy (V70), 60 Gy (V60), 40 Gy (V40) and 20 Gy (V20) were compared between ≤ Grade 1 and ≥ Grade 2 toxicity groups using the Student's t-test. Multivariable logistic regression analysis of the factors that appeared to be associated with the risk of late rectal toxicity (as determined by the Student's t-test) was performed. The median follow-up time was 35 months. Late Grade 2-3 rectal toxicity was observed in 18 patients (7.4%). Age, the maximum dose of the rectum, V70 and V60 of the ≥ Grade 2 toxicity group were significantly higher than in those of the ≤ Grade 1 toxicity group (P=0.00093, 0.048, 0.0030 and 0.0021, respectively). No factor was significant in the multivariable analysis. The result of this study indicates that the risk of late rectal toxicity correlates with the rectal volume exposed to high doses of HT for localized prostate cancer. Further follow-up and data accumulation may establish dose-volume modeling to predict rectal complications after HT. (author)

  5. Stereotactic body radiation therapy via helical tomotherapy to replace brachytherapy for brachytherapy-unsuitable cervical cancer patients – a preliminary result

    Directory of Open Access Journals (Sweden)

    Hsieh CH

    2013-02-01

    Full Text Available Chen-Hsi Hsieh,1–3 Hui-Ju Tien,1 Sheng-Mou Hsiao,4 Ming-Chow Wei,4 Wen-Yih Wu,4 Hsu-Dong Sun,4 Li-Ying Wang,5 Yen-Ping Hsieh,6 Yu-Jen Chen,3,7–9 Pei-Wei Shueng1,101Department of Radiation Oncology, Far Eastern Memorial Hospital, Taipei, Taiwan; 2Department of Medicine, 3Institute of Traditional Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan; 4Department of Obstetrics and Gynecology, Far Eastern Memorial Hospital, Taipei, Taiwan; 5School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan; 6Department of Senior Citizen Service Management, National Taichung University of Science and Technology, Taichung, Taiwan; 7Department of Radiation Oncology, 8Department of Medical Research, Mackay Memorial Hospital, Taipei, Taiwan; 9Graduate Institute of Sport Coaching Science, Chinese Culture University, Taipei, Taiwan; 10Department of Radiation Oncology, National Defense Medical Center, Taipei, TaiwanAim: To review the experience and to evaluate the results of stereotactic body radiation therapy (SBRT via helical tomotherapy (HT, for the treatment of brachytherapy-unsuitable cervical cancer.Methods: Between September 1, 2008 to January 31, 2012, nine cervical cancer patients unsuitable for brachytherapy were enrolled. All of the patients received definitive whole pelvic radiotherapy with or without chemotherapy, followed by SBRT via HT.Results: The actuarial locoregional control rate at 3 years was 78%. The mean biological equivalent dose in 2-Gy fractions of the tumor, rectum, bladder, and intestines was 76.0 ± 7.3, 73.8 ± 13.2, 70.5 ± 10.0, and 43.1 ± 7.1, respectively. Only two had residual tumors after treatment, and the others were tumor-free. Two patients experienced grade 3 acute toxicity: one had diarrhea; and another experienced thrombocytopenia. There were no grade 3 or 4 subacute toxicities. Three patients suffered from manageable rectal bleeding in

  6. Dosimetric comparison between helical tomotherapy and intensity-modulated radiation therapy plans for non-small cell lung cancer.

    Science.gov (United States)

    Meng, Ling-Ling; Feng, Lin-Chun; Wang, Yun-Lai; Dai, Xiang-Kun; Xie, Chuan-Bin

    2011-06-01

    Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformity, dose gradients, and protection for the lung than IMRT plan. We compared the dosimetric characteristics of HT for NSCLC with those of conventional IMRT to observe the superiority of HT. There was a comparative case series comprising 10 patients with NSCLC. Computed tomographic (CT) images of delineated targets were transferred to the PrecisePlan planning system (IMRT) and Tomo planning system (HT). The prescription doses were 70 Gy/33F for the gross tumor volume (GTV) and the visible lymph nodes (GTVnd), and 60 Gy/33F for the clinical target volume (CTV) and the clinical target volume of the visible lymph nodes (CTVnd). The dose restrictions for organs at risk were as follows: the maximum dose to spinal cord ≤ 45 Gy, V20 to the total lungs 0.05). The maximum doses to the spinal cord, heart, esophagus and trachea in the HT plan were lower than those in the IMRT plan, but the differences were not statistically significant. The HT plan provids better dose uniformity, dose gradients, and protection for the organs at risk. It can reduce the high-dose radiation volume for lung and the MLD, but may deliver a larger lung volume of low-dose radiation.

  7. Patient- and therapy-related factors associated with the incidence of xerostomia in nasopharyngeal carcinoma patients receiving parotid-sparing helical tomotherapy.

    Science.gov (United States)

    Lee, Tsair-Fwu; Liou, Ming-Hsiang; Ting, Hui-Min; Chang, Liyun; Lee, Hsiao-Yi; Wan Leung, Stephen; Huang, Chih-Jen; Chao, Pei-Ju

    2015-08-20

    We investigated the incidence of moderate to severe patient-reported xerostomia among nasopharyngeal carcinoma (NPC) patients treated with helical tomotherapy (HT) and identified patient- and therapy-related factors associated with acute and chronic xerostomia toxicity. The least absolute shrinkage and selection operator (LASSO) normal tissue complication probability (NTCP) models were developed using quality-of-life questionnaire datasets from 67 patients with NPC. For acute toxicity, the dosimetric factors of the mean doses to the ipsilateral submandibular gland (Dis) and the contralateral submandibular gland (Dcs) were selected as the first two significant predictors. For chronic toxicity, four predictive factors were selected: age, mean dose to the oral cavity (Doc), education, and T stage. The substantial sparing data can be used to avoid xerostomia toxicity. We suggest that the tolerance values corresponded to a 20% incidence of complications (TD20) for Dis = 39.0 Gy, Dcs = 38.4 Gy, and Doc = 32.5 Gy, respectively, when mean doses to the parotid glands met the QUANTEC 25 Gy sparing guidelines. To avoid patient-reported xerostomia toxicity, the mean doses to the parotid gland, submandibular gland, and oral cavity have to meet the sparing tolerance, although there is also a need to take inherent patient characteristics into consideration.

  8. A Dosimetric Comparison of Accelerated Partial Breast Irradiation Techniques: Multicatheter Interstitial Brachytherapy, Three-Dimensional Conformal Radiotherapy, and Supine Versus Prone Helical Tomotherapy

    International Nuclear Information System (INIS)

    Patel, Rakesh R.; Becker, Stewart J.; Das, Rupak K.; Mackie, Thomas R.

    2007-01-01

    Purpose: To compare dosimetrically four different techniques of accelerated partial breast irradiation (APBI) in the same patient. Methods and Materials: Thirteen post-lumpectomy interstitial brachytherapy (IB) patients underwent imaging with preimplant computed tomography (CT) in the prone and supine position. These CT scans were then used to generate three-dimensional conformal radiotherapy (3D-CRT) and prone and supine helical tomotherapy (PT and ST, respectively) APBI plans and compared with the treated IB plans. Dose-volume histogram analysis and the mean dose (NTD mean ) values were compared. Results: Planning target volume coverage was excellent for all methods. Statistical significance was considered to be a p value mean dose of 1.3 Gy 3 and 1.2 Gy 3 , respectively. Both of these methods were statistically significantly lower than the supine external beam techniques. Overall, all four methods yielded similar low doses to the heart. Conclusions: The use of IB and PT resulted in greater normal tissue sparing (especially ipsilateral breast and lung) than the use of supine external beam techniques of 3D-CRT or ST. However, the choice of APBI technique must be tailored to the patient's anatomy, lumpectomy cavity location, and overall treatment goals

  9. Reference dosimetry for helical tomotherapy: Practical implementation and a multicenter validation

    International Nuclear Information System (INIS)

    De Ost, B.; Schaeken, B.; Vynckier, S.; Sterpin, E.; Van den Weyngaert, D.

    2011-01-01

    Purpose: The aim of this study was to implement a protocol for reference dosimetry in tomotherapy and to validate the beam output measurements with an independent dosimetry system. Methods: Beam output was measured at the reference depth of 10 cm in water for the following three cases: (1) a 5 x 10 cm 2 static machine specific reference field (MSR), (2) a rotational 5 x 10 cm 2 field without modulation and no tabletop in the beam, (3) a plan class specific reference (PCSR) field defined as a rotational homogeneous dose delivery to a cylindrical shaped target volume: plan with modulation and table-top movement. The formalism for reference dosimetry of small and nonstandard fields [Med.Phys.35: 5179-5186, 2008] and QA recommendations [Med.Phys.37: 4817-4853, 2010] were adopted in the dose measurement protocol. All ionization chamber measurements were verified independently using alanine/EPR dosimetry. As a pilot study, the beam output was measured on tomotherapy Hi-art systems at three other centers and directly compared to the centers specifications and to alanine dosimetry. Results: For the four centers, the mean static output at a depth of 10 cm in water and SAD = 85 cm, measured with an A1SL chamber following the TG-148 report was 6.238 Gy/min ± 0.058 (1 SD); the rotational output was 6.255 Gy/min ± 0.069 (1 SD). The dose stated by the center was found in good agreement with the measurements of the visiting team: D center /D visit = 1.000 ± 0.003 (1 SD). The A1SL chamber measurements were all in good agreement with Alanine/EPR dosimetry. Going from the static reference field to the rotational/non modulated field the dose rate remains constant within 0.2% except for one center where a deviation of 1.3% was detected. Conclusions: Following the TG-148 report, beam output measurements in water at the reference depth using a local protocol, as developed at different centers, was verified. The measurements were found in good agreement with alanine/EPR dosimetry. The

  10. Dose-volume effects for pelvic bone marrow in predicting hematological toxicity in prostate cancer radiotherapy with pelvic node irradiation.

    Science.gov (United States)

    Sini, Carla; Fiorino, Claudio; Perna, Lucia; Noris Chiorda, Barbara; Deantoni, Chiara Lucrezia; Bianchi, Marco; Sacco, Vincenzo; Briganti, Alberto; Montorsi, Francesco; Calandrino, Riccardo; Di Muzio, Nadia; Cozzarini, Cesare

    2016-01-01

    To prospectively identify clinical/dosimetric predictors of acute/late hematologic toxicity (HT) in chemo-naÏve patients treated with whole-pelvis radiotherapy (WPRT) for prostate cancer. Data of 121 patients treated with adjuvant/salvage WPRT were analyzed (static-field IMRT n=19; VMAT/Rapidarc n=57; Tomotherapy n=45). Pelvic bone marrow (BM) was delineated as ilium (IL), lumbosacral, lower and whole pelvis (WP), and the relative DVHs were calculated. HT was graded both according to CTCAE v4.03 and as variation in percentage relative to baseline. Logistic regression was used to analyze association between HT and clinical/DVHs factors. Significant differences (p<0.005) in the DVH of BM volumes between different techniques were found: Tomotherapy was associated with larger volumes receiving low doses (3-20 Gy) and smaller receiving 40-50 Gy. Lower baseline absolute values of WBC, neutrophils and lymphocytes (ALC) predicted acute/late HT (p ⩽ 0.001). Higher BM V40 was associated with higher risk of acute Grade3 (OR=1.018) or late Grade2 lymphopenia (OR=1.005). Two models predicting lymphopenia were developed, both including baseline ALC, and BM WP-V40 (AUC=0.73) and IL-V40+smoking (AUC=0.904) for acute/late respectively. Specific regions of pelvic BM predicting acute/late lymphopenia, a risk factor for viral infections, were identified. The 2-variable models including specific constraints to BM may help reduce HT. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Selection of the optimal radiotherapy technique for locally advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Lee, Ik-Jae; Seong, Jinsil; Koom, Woong-Sub; Kim, Yong-Bae; Jeon, Byeong-Chul; Kim, Joo-Ho; Han, Kwang-Hyub

    2011-01-01

    Various techniques are available for radiotherapy of hepatocellular carcinoma, including three-dimensional conformal radiotherapy, linac-based intensity-modulated radiotherapy and helical tomotherapy. The purpose of this study was to determine the optimal radiotherapy technique for hepatocellular carcinoma. Between 2006 and 2007, 12 patients underwent helical tomotherapy for locally advanced hepatocellular carcinoma. Helical tomotherapy computerized radiotherapy planning was compared with the best computerized radiotherapy planning for three-dimensional conformal radiotherapy and linac-based intensity-modulated radiotherapy for the delivery of 60 Gy in 30 fractions. Tumor coverage was assessed by conformity index, radical dose homogeneity index and moderated dose homogeneity index. Computerized radiotherapy planning was also compared according to the tumor location. Tumor coverage was shown to be significantly superior with helical tomotherapy as assessed by conformity index and moderated dose homogeneity index (P=0.002 and 0.03, respectively). Helical tomotherapy showed significantly lower irradiated liver volume at 40, 50 and 60 Gy (V40, V50 and V60, P=0.04, 0.03 and 0.01, respectively). On the contrary, the dose-volume of three-dimensional conformal radiotherapy at V20 was significantly smaller than those of linac-based intensity-modulated radiotherapy and helical tomotherapy in the remaining liver (P=0.03). Linac-based intensity-modulated radiotherapy showed better sparing of the stomach compared with helical tomotherapy in the case of separated lesions in both lobes (12.3 vs. 24.6 Gy). Helical tomotherapy showed the high dose-volume exposure to the left kidney due to helical delivery in the right lobe lesion. Helical tomotherapy achieved the best tumor coverage of the remaining normal liver. However, helical tomotherapy showed much exposure to the remaining liver at the lower dose region and left kidney. (author)

  12. SU-E-T-371: Validation of Organ Doses Delivered During Craniospinal Irradiation with Helical Tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Andujar, A; Chen, J; Garcia, A; Haas-Kogan, D [University of San Francisco, San Francisco, CA (United States)

    2014-06-01

    Purpose: New techniques have been developed to deliver more conformal treatments to the craniospinal axis. One concern, however, is the widespread low dose delivered and implications for possible late effects. The purpose of this work is for the first time to validate the organ doses calculated by the treatment planning system (TPS), including out-of-field doses for a pediatric craniospinal treatment (CSI). Methods: A CSI plan prescribed to 23.4 Gy and a posterior fossa boost plan to 30.6 Gy (total dose 54.0 Gy) was developed for a pediatric anthropomorphic phantom representing a 13 yearold- child. For the CSI plan, the planning target volumes (PTV) consisted of the brain and spinal cord with 2 mm and 5 mm expansions, respectively. Organs at risk (OAR) were contoured and included in the plan optimization. The plans were delivered on a helical tomotherapy unit. Thermoluminescent dosimeters (TLDs) were used to measure the dose at 54 positions within the PTV and OARs. Results: For the CSI treatment, the mean percent difference between TPS dose calculations and measurements was 5% for the PTV and 10% for the OARs. For the boost, the average was 3% for the PTV. The percent difference for the OARs, which lie outside the field and received a small fraction of the prescription dose, varied from 15% to 200%. However in terms of absolute dose, the average difference between measurement and TPS per treatment Gy was 2 cGy/Gy and 3 mGy/Gy for the CSI and boost plans, respectively. Conclusion: There was good agreement between doses calculated by the TPS and measurements for the CSI treatment. Higher percent differences were observed for out-of-field doses in the boost plan, but absolute dose differences were very small compared to the prescription dose. These findings can help in the estimation of late effects after radiotherapy for pediatric patients.

  13. Adaptive radiotherapy for soft tissue changes during helical tomotherapy for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Duma, M.N.; Kampfer, S.; Winkler, C.; Geinitz, H. [Universitaetsklinikum rechts der Isar, Muenchen (Germany). Dept. of Radiation Oncology; Schuster, T. [Universitaetsklinikum rechts der Isar, Muenchen (Germany). Inst. of Medical Statistics and Epidemiology

    2012-03-15

    The goal of the present study was to assess the frequency and impact of replanning triggered solely by soft tissue changes observed on the daily setup mega-voltage CT (MVCT) in head and neck cancer (H and N) helical tomotherapy (HT). A total of 11 patients underwent adaptive radiotherapy (ART) using MVCT. Preconditions were a soft tissue change > 0.5 cm and a tight mask. The dose-volume histograms (DVHs) derived from the initial planning kVCT (inPlan), the recalculated DVHs of the fraction (fx) when replanning was decided (actSit) and the DVHs of the new plan (adaptPlan) were compared. Assessed were the following: maximum dose (D{sub max}), minimum dose (D{sub min}), and mean dose (D{sub mean}) to the planning target volume (PTV) normalized to the prescribed dose; the D{sub mean}/fx to the parotid glands (PG), oral cavity (OC), and larynx (Lx); and the D{sub max}/fx to the spinal cord (SC) in Gy/fx. No patient had palpable soft tissue changes. The median weight loss at the moment of replanning was 2.3 kg. The median PTV D{sub mean} was 100% for inPlan, 103% for actSit, and 100% for adaptPlan. The PTV was always covered by the prescribed dose. A statistically significant increase was noted for all organs at risk (OAR) in the actSit. The D{sub mean} to the Lx, the D{sub mean} to the OC and the D{sub max} to the SC were statistically better in the adaptPlan. No statistically significant improvement was achieved by ART for the PGs. No significant correlations between weight and volume loss or between the volume changes of the organs to each other were observed, except a strong positive correlation of the shrinkage of the PGs ({rho} = + 0.77, p = 0.005). Soft tissue shrinkage without clinical palpable changes will not affect the coverage of the PTV, but translates into a higher delivered dose to the PTV itself and the normal tissue outside the PTV. The gain by ART in individual patients - especially in patients who receive doses close to the tolerance doses of the OAR

  14. Cerebrospinal tomo-therapy

    International Nuclear Information System (INIS)

    Fumagalli, I.; Coche-Dequeant, B.; Lacornerie, T.; Reynaert, N.; Lartigau, E.

    2010-01-01

    The authors report the study of the feasibility of a cerebrospinal tomo-therapy, of the protection of organs at risk, and of tolerance. Nine patients have been treated, one with a bi-fractionated irradiation and the others with a conventional fractionation. Seven had chemotherapy before radiotherapy, and two had intensification with self-grafting of stem cells. The dose constraints and the planning target volume (PTV) differed with respect to the treated organ (kidney, lung, thyroid, parotid, hypophysis). The tolerance was good. It appears that cerebrospinal tomo-therapy results in a better comfort for the patient and an easier treatment plan with a good dose homogeneity. Short communication

  15. Head and neck region consolidation radiotherapy and prophylactic cranial irradiation with hippocampal avoidance delivered with helical tomotherapy after induction chemotherapy for non-sinonasal neuroendocrine carcinoma of the upper airways

    International Nuclear Information System (INIS)

    Franco, Pierfrancesco; La Porta, Maria Rosa; Girelli, Giuseppe; Borca, Valeria Casanova; Pasquino, Massimo; Tofani, Santi; Ozzello, Franca; Ricardi, Umberto; Numico, Gianmauro; Migliaccio, Fernanda; Catuzzo, Paola; Cante, Domenico; Ceroni, Paola; Sciacero, Piera; Carassai, Pierpaolo; Canzi, Paolo

    2012-01-01

    Non-sinonasal neuroendocrine carcinomas (NSNECs) of the head and neck are considered an unfrequent clinico-pathological entity. Combined modality treatment represents an established therapeutic option for undifferentiated forms where distant metastasis is a common pattern of failure. We report on a case of NSNEC treated with sequential chemo-radiation consisting of 6 cycles of cisplatin and etoposide followed by loco-regional radiation to the head and neck and simultaneous prophylactic cranial irradiation to prevent from intracranial spread, delivered with helical tomotherapy with the 'hippocampal avoidance' technique in order to reduce neuro-cognitive late effects. One year after the end of the whole combined modality approach, the patient achieved complete remission, with no treatment-related sub-acute and late effects. The present report highlights the importance of multidisciplinary management for NSNECs of the head and neck, as the possibility to achieve substantial cure rates with mild side effects with modern radiotherapy techniques

  16. Critical structure sparing in stereotactic ablative radiotherapy for central lung lesions: helical tomotherapy vs. volumetric modulated arc therapy.

    Directory of Open Access Journals (Sweden)

    Alexander Chi

    Full Text Available BACKGROUND: Helical tomotherapy (HT and volumetric modulated arc therapy (VMAT are both advanced techniques of delivering intensity-modulated radiotherapy (IMRT. Here, we conduct a study to compare HT and partial-arc VMAT in their ability to spare organs at risk (OARs when stereotactic ablative radiotherapy (SABR is delivered to treat centrally located early stage non-small-cell lung cancer or lung metastases. METHODS: 12 patients with centrally located lung lesions were randomly chosen. HT, 2 & 8 arc (Smart Arc, Pinnacle v9.0 plans were generated to deliver 70 Gy in 10 fractions to the planning target volume (PTV. Target and OAR dose parameters were compared. Each technique's ability to meet dose constraints was further investigated. RESULTS: HT and VMAT plans generated essentially equivalent PTV coverage and dose conformality indices, while a trend for improved dose homogeneity by increasing from 2 to 8 arcs was observed with VMAT. Increasing the number of arcs with VMAT also led to some improvement in OAR sparing. After normalizing to OAR dose constraints, HT was found to be superior to 2 or 8-arc VMAT for optimal OAR sparing (meeting all the dose constraints (p = 0.0004. All dose constraints were met in HT plans. Increasing from 2 to 8 arcs could not help achieve optimal OAR sparing for 4 patients. 2/4 of them had 3 immediately adjacent structures. CONCLUSION: HT appears to be superior to VMAT in OAR sparing mainly in cases which require conformal dose avoidance of multiple immediately adjacent OARs. For such cases, increasing the number of arcs in VMAT cannot significantly improve OAR sparing.

  17. Fast Helical Tomotherapy in a head and neck cancer planning study: is time priceless?

    International Nuclear Information System (INIS)

    Van Gestel, Dirk; De Kerf, Geert; Wouters, Kristien; Crijns, Wouter; Vermorken, Jan B.; Gregoire, Vincent; Verellen, Dirk

    2015-01-01

    The last few years, in radiotherapy there has been a growing focus on speed of treatment delivery (largely driven by economical and commercial interests). This study investigates the influence of treatment time on plan quality for helical tomotherapy (HT), using delivery times with Volumetric Modulated Arc Therapy (VMAT; Rapid Arc [RA]) as reference. In a previous study, double arc RA (Eclipse) and standard HT plans (TomoHD™) were created for five oropharyngeal cancer patients and reported according to ICRU 83 guidelines. By modifying the beam width from 2.5 to 5.0 cm, elevating the pitch and lowering the modulation factor, “TomoFast” (TF) plans were generated with treatment times equal to RA plans. To quantify the impact of TF’s craniocaudal gradient, similar plans were generated on TomoEdge TM (TomoEdgeFast;TEF). The homogeneity index (HI), conformity index (CI), mean dose, D near-max (D2) and D near-min (D98) of the PTVs were analyzed as well as the mean dose, specific critical doses and volumes of 26 organs at risk (OARs). Data were analyzed using repeated measures ANOVA. With a mean treatment time of 3.05 min (RA), 2.89 min (TF) and 2.95 min (TEF), PTV therapeutic coverage was more homogeneous with TF (HI.07;SE.01) and TEF (HI.08;SE.01) compared to RA (HI.10;SE.01), while PTV prophylactic was most homogeneous with RA. Mean doses to parotid glands were comparable for RA, TF, TEF: 25.62, 25.34, 23.09 Gy for contralateral and 32.02, 31.96, 30.01 Gy for ipsilateral glands, respectively. OARs’ mean doses varied between different approaches not favoring a particular technique. TF’s higher dose to OARs at the cranial-caudal edges of the PTVs and its higher integral dose, both due to the extended cranial-caudal gradient, seems to be solved by the new TomoEdge™ software. However, all these faster techniques lose part of standard TomoHD’s OAR sparing capacity It is possible to treat oropharyngeal cancer patients using HT (TF/TEF) within time

  18. Three-dimensional analysis of the respiratory interplay effect in helical tomotherapy: Baseline variations cause the greater part of dose inhomogeneities seen.

    Science.gov (United States)

    Tudor, G Samuel J; Harden, Susan V; Thomas, Simon J

    2014-03-01

    Dose differences from those planned can occur due to the respiratory interplay effect on helical tomotherapy. The authors present a technique to calculate single-fraction doses in three-dimensions resulting from craniocaudal motion applied to a patient CT set. The technique is applied to phantom and patient plans using patient respiratory traces. An additional purpose of the work is to determine the contribution toward the interplay effect of different components of the respiratory trace. MATLAB code used to calculate doses to a CT dataset from a helical tomotherapy plan has been modified to permit craniocaudal motion and improved temporal resolution. Real patient traces from seven patients were applied to ten phantom plans of differing field width, modulation factor, pitch and fraction dose, and simulations made with peak-to-peak amplitudes ranging from 0 to 2.5 cm. PTV voxels near the superior or inferior limits of the PTV are excluded from the analysis. The maximum dose discrepancy compared with the static case recorded along with the proportion of voxels receiving more than 10% and 20% different from prescription dose. The analysis was repeated with the baseline variation of the respiratory trace removed, leaving the cyclic component of motion only. Radiochromic film was used on one plan-trace combination and compared with the software simulation. For one case, filtered traces were generated and used in simulations which consisted only of frequencies near to particular characteristic frequencies of the treatment delivery. Intraslice standard deviation of dose differences was used to identify potential MLC interplay, which was confirmed using nonmodulated simulations. Software calculations were also conducted for four realistic patient plans and modeling movement of a patient CT set with amplitudes informed by the observed motion of the GTV on 4DCT. The maximum magnitude of dose difference to a PTV voxel due to the interplay effect within a particular plan

  19. Fast Megavoltage Computed Tomography: A Rapid Imaging Method for Total Body or Marrow Irradiation in Helical Tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Magome, Taiki [Department of Radiological Sciences, Faculty of Health Sciences, Komazawa University, Tokyo (Japan); Department of Radiology, The University of Tokyo Hospital, Tokyo (Japan); Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota (United States); Haga, Akihiro [Department of Radiology, The University of Tokyo Hospital, Tokyo (Japan); Takahashi, Yutaka [Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota (United States); Department of Radiation Oncology, Osaka University, Osaka (Japan); Nakagawa, Keiichi [Department of Radiology, The University of Tokyo Hospital, Tokyo (Japan); Dusenbery, Kathryn E. [Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Hui, Susanta K., E-mail: shui@coh.org [Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota (United States); Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Department of Radiation Oncology and Beckman Research Institute, City of Hope, Duarte, California (United States)

    2016-11-01

    Purpose: Megavoltage computed tomographic (MVCT) imaging has been widely used for the 3-dimensional (3-D) setup of patients treated with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, the result of slow couch speeds of approximately 1 mm/s, which can be difficult for the patient to tolerate. We sought to develop an MVCT imaging method allowing faster couch speeds and to assess its accuracy for image guidance for HT. Methods and Materials: Three cadavers were scanned 4 times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm with a penalty term of total variation and with a conventional filtered back projection (FBP) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors from the 2 reconstruction algorithms were compared. This fast MVCT imaging was tested in 3 cases of total marrow irradiation as a clinical trial. Results: The 3-D registration errors of the MVCT images reconstructed with the IR algorithm were smaller than the errors of images reconstructed with the FBP algorithm at fast couch speeds (2, 3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, faster MVCT (3 mm/s couch speed) scanning reduced the imaging time and still generated images useful for anatomic registration. Conclusions: Fast MVCT with the IR algorithm is clinically feasible for large 3-D target localization, which may reduce the overall time for the treatment procedure. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area. Automated integration of this imaging is at least needed to further assess its clinical benefits.

  20. Effect of image value-to-density table (IVDT) on the accuracy of delivery quality assurance (DQA) process in helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ju-Young [Department of Radiation Oncology, Chonnam National University Medical School, Gwangju (Korea, Republic of); Ahn, Sung-Ja, E-mail: dandy@catholic.ac.kr [Department of Radiation Oncology, Chonnam National University Medical School, Gwangju (Korea, Republic of)

    2012-10-01

    The effect of the accuracy in the application of the image value-to-density table (IVDT) from kilovoltage computed tomography (kVCT) and mega-voltage computed tomography (MVCT) images on the delivery quality assurance (DQA) in helical tomotherapy (HT) was analyzed. The DQA plans were prepared with a kVCT image of a cheese phantom for 10 HT patients, and the difference in absolute dose equivalence between the planned and real measurement was evaluated according to the accuracy of IVDT application. The difference between the calculated dose distribution and real dose distribution measured with MapCHECK (SunNuclear, Melbourne, FL) was analyzed through the DQA process with a kVCT MapCHECK image and the same analysis was performed with an MVCT MapCHECK image. The IVDT for kVCT was applied to MVCT and the variation in error between the planned and real measurement caused by improper application of IVDT was evaluated. The accuracy of the IVDT application in the homogeneous water-equivalent cheese phantom had only a minor influence on the dose calculation. Although the overall accuracy of the calculated dose was increased when the proper IVDT was applied, this result had no statistical significance. The MVCT image of MapCHECK contained less error between the calculated dose and delivered dose with a high pass rate. The proper IVDT application to the MVCT image of MapCHECK increased the accuracy of dose calculation, and this result had a statistical significance. Application of the correct IVDT is important in HT DQA and its significance is increased when using phantoms consisting of inhomogeneous density materials.

  1. Comparison of the effectiveness of different immobilization systems in different body regions using daily megavoltage CT in helical tomotherapy

    Science.gov (United States)

    Cheng, K-F

    2014-01-01

    Objective: Effective immobilization is crucial for the accurate delivery of radiotherapy. This study aimed to compare the effectiveness of the commonly used immobilization systems for different body regions using megavoltage CT (MVCT). Methods: Daily treatment set-up data from 212 patients treated by helical tomotherapy (Accuray, Sunnyvale, CA) in 6 body regions (52 head and neck, 41 chest, 38 abdomen, 36 pelvis, 18 breast and 27 cranium) were obtained. Based on a verification tool using the pre-treatment MVCT, set-up corrections for each patient were recorded. Mean systematic and random errors of lateral, longitudinal, vertical and roll directions and three-dimensional vectors were compared between immobilization systems of each region. Results: Smaller set-up deviations were observed in the Orfit system (Orfit Industries NV, Wijnegem, Belgium) of the head and neck region, while the performance of immobilization systems for the chest, abdomen and pelvis regions was similar. Larger differences were noted in the breast group, where the prone BodyFIX® system (Medical Intelligence, Medizintechnik GmbH, Schwabmünchen, Germany) was less stable than the supine VacLok® system (CIVCO Medical Solutions, Orange City, IA). Conclusion: Differences were found between the immobilization systems in the head and neck region, in which the Orfit system was relatively more effective, whereas the VacLok and BodyFIX systems performed similarly in the chest, abdomen and pelvis regions. For the breast case, the supine position with VacLok was much more stable than the prone breast technique. The results provided references for the estimation of clinical target volume–planning target volume margins. Advances in knowledge: This is the first article on comprehensive comparisons performed in immobilization systems for main body regions that provides some practical recommendations. PMID:24398111

  2. Helical tomotherapy in the treatment of pediatric malignancies: a preliminary report of feasibility and acute toxicity

    Directory of Open Access Journals (Sweden)

    Beltrán César

    2011-08-01

    Full Text Available Abstract Background Radiation therapy plays a central role in the management of many childhood malignancies and Helical Tomotherapy (HT provides potential to decrease toxicity by limiting the radiation dose to normal structures. The aim of this article was to report preliminary results of our clinical experience with HT in pediatric malignancies. Methods In this study 66 consecutive patients younger than 14 years old, treated with HT at our center between January 2006 and April 2010, have been included. We performed statistical analyses to assess the relationship between acute toxicity, graded according to the RTOG criteria, and several clinical and treatment characteristics such as a dose and irradiation volume. Results The median age of patients was 5 years. The most common tumor sites were: central nervous system (57%, abdomen (17% and thorax (6%. The most prevalent histological types were: medulloblastoma (16 patients, neuroblastoma (9 patients and rhabdomyosarcoma (7 patients. A total of 52 patients were treated for primary disease and 14 patients were treated for recurrent tumors. The majority of the patients (72% were previously treated with chemotherapy. The median prescribed dose was 51 Gy (range 10-70 Gy. In 81% of cases grade 1 or 2 acute toxicity was observed. There were 11 cases (16,6% of grade 3 hematological toxicity, two cases of grade 3 skin toxicity and one case of grade 3 emesis. Nine patients (13,6% had grade 4 hematological toxicity. There were no cases of grade 4 non-hematological toxicities. On the univariate analysis, total dose and craniospinal irradiation (24 cases were significantly associated with severe toxicity (grade 3 or more, whereas age and chemotherapy were not. On the multivariate analysis, craniospinal irradiation was the only significant independent risk factor for grade 3-4 toxicity. Conclusion HT in pediatric population is feasible and safe treatment modality. It is characterized by an acceptable level of

  3. Helical tomotherapy in the treatment of pediatric malignancies: a preliminary report of feasibility and acute toxicity

    International Nuclear Information System (INIS)

    Mesbah, Latifa; Marsiglia, Hugo; Matute, Raúl; Usychkin, Sergey; Marrone, Immacolata; Puebla, Fernando; Mínguez, Cristina; García, Rafael; García, Graciela; Beltrán, César

    2011-01-01

    Radiation therapy plays a central role in the management of many childhood malignancies and Helical Tomotherapy (HT) provides potential to decrease toxicity by limiting the radiation dose to normal structures. The aim of this article was to report preliminary results of our clinical experience with HT in pediatric malignancies. In this study 66 consecutive patients younger than 14 years old, treated with HT at our center between January 2006 and April 2010, have been included. We performed statistical analyses to assess the relationship between acute toxicity, graded according to the RTOG criteria, and several clinical and treatment characteristics such as a dose and irradiation volume. The median age of patients was 5 years. The most common tumor sites were: central nervous system (57%), abdomen (17%) and thorax (6%). The most prevalent histological types were: medulloblastoma (16 patients), neuroblastoma (9 patients) and rhabdomyosarcoma (7 patients). A total of 52 patients were treated for primary disease and 14 patients were treated for recurrent tumors. The majority of the patients (72%) were previously treated with chemotherapy. The median prescribed dose was 51 Gy (range 10-70 Gy). In 81% of cases grade 1 or 2 acute toxicity was observed. There were 11 cases (16,6%) of grade 3 hematological toxicity, two cases of grade 3 skin toxicity and one case of grade 3 emesis. Nine patients (13,6%) had grade 4 hematological toxicity. There were no cases of grade 4 non-hematological toxicities. On the univariate analysis, total dose and craniospinal irradiation (24 cases) were significantly associated with severe toxicity (grade 3 or more), whereas age and chemotherapy were not. On the multivariate analysis, craniospinal irradiation was the only significant independent risk factor for grade 3-4 toxicity. HT in pediatric population is feasible and safe treatment modality. It is characterized by an acceptable level of acute toxicity that we have seen in this highly

  4. Validation of GPU based TomoTherapy dose calculation engine.

    Science.gov (United States)

    Chen, Quan; Lu, Weiguo; Chen, Yu; Chen, Mingli; Henderson, Douglas; Sterpin, Edmond

    2012-04-01

    The graphic processing unit (GPU) based TomoTherapy convolution/superposition(C/S) dose engine (GPU dose engine) achieves a dramatic performance improvement over the traditional CPU-cluster based TomoTherapy dose engine (CPU dose engine). Besides the architecture difference between the GPU and CPU, there are several algorithm changes from the CPU dose engine to the GPU dose engine. These changes made the GPU dose slightly different from the CPU-cluster dose. In order for the commercial release of the GPU dose engine, its accuracy has to be validated. Thirty eight TomoTherapy phantom plans and 19 patient plans were calculated with both dose engines to evaluate the equivalency between the two dose engines. Gamma indices (Γ) were used for the equivalency evaluation. The GPU dose was further verified with the absolute point dose measurement with ion chamber and film measurements for phantom plans. Monte Carlo calculation was used as a reference for both dose engines in the accuracy evaluation in heterogeneous phantom and actual patients. The GPU dose engine showed excellent agreement with the current CPU dose engine. The majority of cases had over 99.99% of voxels with Γ(1%, 1 mm) engine also showed similar degree of accuracy in heterogeneous media as the current TomoTherapy dose engine. It is verified and validated that the ultrafast TomoTherapy GPU dose engine can safely replace the existing TomoTherapy cluster based dose engine without degradation in dose accuracy.

  5. Tomotherapeutic stereotactic body radiation therapy: Techniques and comparison between modalities

    International Nuclear Information System (INIS)

    Fuss, Martin; Chengyu Shi; Papanikolaou, Niko

    2006-01-01

    Presentation and comparison of tomotherapeutic intensity-modulated techniques for planning and delivery of stereotactic body radiation therapy. Serial tomotherapeutic SBRT has been planned and delivered at our institution since 8/2001. Since 12/2005, 12 patients have been treated using a helical tomotherapy unit. For these 12 patients both helical and serial tomotherapy plans were computed and clinically approved. Techniques and considerations of tomotherapy SBRT planning, associated image-guidance, and delivery are presented. The respective treatment plans were compared based on dosimetric parameters as well as time to develop a treatment plan and delivery times. Also the associated quality of megavoltage CT (MVCT) image-guidance inherent to the helical tomotherapy unit was assessed. Tumor volumes averaged 9.3, 9.8, and 58.7 cm 3 for liver, lung, and spinal targets. Helical and serial tomotherapy plans showed comparable plan quality with respect to maximum and average doses to the gross tumor and planning target volumes. Time to develop helical tomotherapy plans averaged 3.5 h while serial tomotherapy planning consistently required less than one hour. Treatment delivery was also slower using helical tomotherapy, with differences of less than 10 min between modalities. MVCT image-guidance proved satisfactory for bony and lung targets, but failed to depict liver lesions, owing to poor soft-tissue contrast. SBRT planning and delivery is clinically feasible using either tomotherapeutic modality. While treatment planning time was consistently shorter and more readily accomplished in a standardized approach using the serial tomotherapy modality, actual plan quality and treatment delivery times are grossly comparable between the modalities. MVCT volumetric image-guidance, was observed to be valuable for thoracic and spinal target volumes, whereas it proved challenging for liver targets

  6. Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

    International Nuclear Information System (INIS)

    Kim, Min-Joo; Park, So-Hyun; Son, Seok-Hyun; Cheon, Keum-Seong; Choi, Byung-Ock; Suh, Tae-Suk

    2013-01-01

    The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue

  7. Practical and clinical considerations in Cobalt-60 tomotherapy

    Directory of Open Access Journals (Sweden)

    Joshi Chandra

    2009-01-01

    Full Text Available Cobalt-60 (Co-60 based radiation therapy continues to play a significant role in not only developing countries, where access to radiation therapy is extremely limited, but also in industrialized countries. Howver, technology has to be developed to accommodate modern techniques, in-clud-ing image guided and adaptive radiation therapy (IGART. In this paper we describe some of the practical and clinical considerations for Co-60 based tomotherapy by comparing Co-60 and 6 MV linac-based tomotherapy plans for a head and neck (HandN cancer and a prostate cancer case. The tomotherapy IMRT plans were obtained by modeling a MIMiC binary multi-leaf collimator attached to a Theratron-780c Co-60 unit and a 6 MV linear accelerator (CL2100EX. The EGSnrc/BEAMnrc Monte Carlo (MC code was used for the modeling of the treatment units with the MIMiC collimator and EGSnrc/DOSXYZnrc code was used for beamlet dose data. An in-house inverse treatment planning program was then used to generate optimized tomotherapy dose distributions for the H and N and prostate cases. The dose distributions, cumulative dose area histograms (DAHs and dose difference maps were used to evaluate and compare Co-60 and 6 MV based tomotherapy plans. A quantitative analysis of the dose distributions and dose-volume histograms shows that both Co-60 and 6 MV plans achieve the plan objectives for the targets (CTV and nodes and OARs (spinal cord in HandN case, and rectum in prostate case.

  8. Extended helical tomo-therapy and concomitant chemotherapy for an uterine cervix carcinoma: dosimetry parameters and hematological toxicity; Tomotherapie helicoidale etendue et chimiotherapie concomitante pour un cancer du col de l'uterus: parametres dosimetriques et toxicite hematologique

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, H.; Thomas, L.; Belhomme, S.; Chemin, A.; Caron, J.; Dejean, C.; Kantor, G.; Richaud, P. [Institut Bergonie, Dept. de Radiotherapie, 33 - Bordeaux (France); Floquet, A.; Guyon, F. [Institut Bergonie, Dept. de Chirurgie, 33 - Bordeaux (France)

    2009-10-15

    the extended tomo-therapy associated to concomitant chemotherapy is feasible and allows a dose escalation at the ganglions level. It is necessary to continue to study the dosimetry parameters at the hematopoietic marrow level that are predictive for a hematological toxicity. (N.C.)

  9. Dosimetric Comparison of Helical Tomotherapy and Dynamic Conformal Arc Therapy in Stereotactic Radiosurgery for Vestibular Schwannomas

    International Nuclear Information System (INIS)

    Lee, Tsair-Fwu; Chao, Pei-Ju; Wang, Chang-Yu; Lan, Jen-Hong; Huang, Yu-Je; Hsu, Hsuan-Chih; Sung, Chieh-Cheng; Su, Te-Jen; Lian, Shi-Long; Fang, Fu-Min

    2011-01-01

    The dosimetric results of stereotactic radiosurgery (SRS) for vestibular schwannoma (VS) performed using dynamic conformal arc therapy (DCAT) with the Novalis system and helical TomoTherapy (HT) were compared using plan quality indices. The HT plans were created for 10 consecutive patients with VS previously treated with SRS using the Novalis system. The dosimetric indices used to compare the techniques included the conformity index (CI) and homogeneity index (HI) for the planned target volume (PTV), the comprehensive quality index (CQI) for nine organs at risk (OARs), gradient score index (GSI) for the dose drop-off outside the PTV, and plan quality index (PQI), which was verified using the plan quality discerning power (PQDP) to incorporate 3 plan indices, to evaluate the rival plans. The PTV ranged from 0.27-19.99 cm 3 (median 3.39 cm 3 ), with minimum required PTV prescribed doses of 10-16 Gy (median 12 Gy). Both systems satisfied the minimum required PTV prescription doses. HT conformed better to the PTV (CI: 1.51 ± 0.23 vs. 1.94 ± 0.34; p < 0.01), but had a worse drop-off outside the PTV (GSI: 40.3 ± 10.9 vs. 64.9 ± 13.6; p < 0.01) compared with DCAT. No significant difference in PTV homogeneity was observed (HI: 1.08 ± 0.03 vs. 1.09 ± 0.02; p = 0.20). HT had a significantly lower maximum dose in 4 OARs and significant lower mean dose in 1 OAR; by contrast, DCAT had a significantly lower maximum dose in 1 OAR and significant lower mean dose in 2 OARs, with the CQI of the 9 OARs = 0.92 ± 0.45. Plan analysis using PQI (HT 0.37 ± 0.12 vs. DCAT 0.65 ± 0.08; p < 0.01), and verified using the PQDP, confirmed the dosimetric advantage of HT. However, the HT system had a longer beam-on time (33.2 ± 7.4 vs. 4.6 ± 0.9 min; p < 0.01) and consumed more monitor units (16772 ± 3803 vs. 1776 ± 356.3; p < 0.01). HT had a better dose conformity and similar dose homogeneity but worse dose gradient than DCAT. Plan analysis confirmed the dosimetric advantage of HT

  10. A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Oliver, Mike; Chen, Jeff; Wong, Eugene; Van Dyk, Jake; Perera, Francisco

    2007-01-01

    Purpose and background: Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast irradiation for their radiation conformity index, dose homogeneity index, and dose to organs at risk. Methods and materials: Small-field tangents, three-dimensional conformal radiation therapy, intensity-modulated radiation therapy and helical tomotherapy were compared for each of 15 patients (7 right, 8 left). One radiation conformity and two dose homogeneity indices were used to evaluate the dose to the target. The mean dose to organs at risk was also evaluated. Results: All proposed APBI techniques improved the conformity index significantly over whole breast tangents while maintaining dose homogeneity and without a significant increase in dose to organs at risk. Conclusion: The four-field IMRT plan produced the best dosimetric results; however this technique would require appropriate respiratory motion management. An alternative would be to use a four-field conformal technique that is less sensitive to the effects of respiratory motion

  11. Measurement of MV CT dose index for Hi-ART helical tomotherapy unit

    International Nuclear Information System (INIS)

    Wang Yunlai; Liao Xiongfei

    2010-01-01

    Objective: To evaluate the patient dose from Hi-ART MV helical CT imaging in image-guided radiotherapy. Methods: Weighted CT dose index (CTDI W ) was measured with PTW TM30009 CT ion chamber in head and body phantoms, respectively,for slice thicknesses of 2, 4, 6 mm with scanned range of 5 cm and 15 cm. Dose length products (DLP) were subsequently calculated. The CTDI W and DLP were compared with XVI kV CBCT and ACQSim simulator CT for routine clinical protocols. Results: An inverse relationship between CTDI and the slice thickness was found. The dose distribution was inhomogeneous owing to the attenuation of the couch. CTDI and DLP had close relationship with the slice thickness and the scanned range. Patient dose from MVCT was lower than XVI CBCT for head, but larger for body scan. Conclusions: CTDI W can be used to assess the patient dose in MV helical CT due to its simplicity for measurement and reproducibility. Regular measurement should be performed in QA and QC program. Appropriate slice thickness and scan range should be chosen to reduce the patient dose. (authors)

  12. Evidence of Limited Motion of the Prostate by Carefully Emptying the Rectum as Assessed by Daily MVCT Image Guidance with Helical Tomotherapy

    International Nuclear Information System (INIS)

    Fiorino, Claudio Ph.D.; Di Muzio, Nadia; Broggi, Sara; Cozzarini, Cesare; Maggiulli, Eleonora M.Sc.; Alongi, Filippo; Valdagni, Riccardo; Fazio, Ferruccio; Calandrino, Riccardo

    2008-01-01

    Purpose: To assess setup and organ motion error by means of analysis of daily megavoltage computed tomography (MVCT) of patients treated with hypofractionated helical tomotherapy (71.4-74.2 Gy in 28 fractions). Methods and Materials: Data from 21 patients were analyzed. Patients were instructed to empty the rectum carefully before planning CT and every morning before therapy by means of a self-applied rectal enema. The position of the prostate was assessed by means of automatic bone matching (BM) with the planning kilovoltage CT (BM, setup error) followed by a direct visualization (DV) match on the prostate. Deviations between planning and therapy positions referred to BM and BM + DV were registered for the three main axes. In case of a full rectum at MVCT with evident shift of the prostate, treatment was postponed until after additional rectal emptying procedures; in this case, additional MVCT was performed before delivering the treatment. Data for 522 fractions were available; the impact of post-MVCT procedure was investigated for 17 of 21 patients (410 fractions). Results: Prostate motion relative to bony anatomy was limited. Concerning posterior-anterior shifts, only 4.9% and 2.7% of fractions showed deviation of 3 mm or greater of the prostate relative to BM without and with consideration of post-MVCT procedures, respectively. Interobserver variability for BM + DV match was within 0.8 mm (1 SD). Conclusions: Daily MVCT-based correction is feasible. The BM + DV matching was found to be consistent between operators. Rectal emptying using a daily enema is an efficient tool to minimize prostate motion, even for centers that have not yet implemented image-guided radiotherapy

  13. Efficacy of virtual block objects in reducing the lung dose in helical tomotherapy planning for cervical oesophageal cancer: a planning study.

    Science.gov (United States)

    Ito, Makoto; Shimizu, Hidetoshi; Aoyama, Takahiro; Tachibana, Hiroyuki; Tomita, Natsuo; Makita, Chiyoko; Koide, Yutaro; Kato, Daiki; Ishiguchi, Tsuneo; Kodaira, Takeshi

    2018-04-04

    Intensity-modulated radiotherapy is useful for cervical oesophageal carcinoma (CEC); however, increasing low-dose exposure to the lung may lead to radiation pneumonitis. Nevertheless, an irradiation technique that avoids the lungs has never been examined due to the high difficulty of dose optimization. In this study, we examined the efficacy of helical tomotherapy that can restrict beamlets passing virtual blocks during dose optimization computing (block plan) in reducing the lung dose. Fifteen patients with CEC were analysed. The primary/nodal lesion and prophylactic nodal region with adequate margins were defined as the planning target volume (PTV)-60 Gy and PTV-48 Gy, respectively. Nineteen plans per patient were made and compared (total: 285 plans), including non-block and block plans with several shapes and sizes. The most appropriate block model was semi-circular, 8 cm outside of the tracheal bifurcation, with a significantly lower lung dose compared to that of non-block plans; the mean lung volumes receiving 5 Gy, 10 Gy, 20 Gy, and the mean lung dose were 31.3% vs. 48.0% (p block and non-block plans were comparable in terms of the homogeneity and conformity indexes of PTV-60 Gy: 0.05 vs. 0.04 (p = 0.100) and 0.82 vs. 0.85 (p = 0.616), respectively. The maximum dose of the spinal cord planning risk volume increased slightly (49.4 Gy vs. 47.9 Gy, p = 0.002). There was no significant difference in the mean doses to the heart and the thyroid gland. Prolongation of the delivery time was less than 1 min (5.6 min vs. 4.9 min, p = 0.010). The block plan for CEC could significantly reduce the lung dose, with acceptable increment in the spinal dose and a slightly prolonged delivery time.

  14. Superiority of conventional intensity-modulated radiotherapy over helical tomotherapy in locally advanced non-small cell lung cancer. A comparative plan analysis

    Energy Technology Data Exchange (ETDEWEB)

    Song, C. [National Cancer Center, Research Institute and Hospital, Goyang (Korea, Republic of). Proton Therapy Center; Seoul National Univ. College of Medicine (Korea, Republic of). Dept. of Radiation Oncology; Pyo, H.; Kim, J. [Sungkyunkwan Univ. School of Medicine, Samsung Medical Center, Seoul (Korea, Republic of). Dept. of Radiation Oncology; Lim, Y.K.; Kim, D.W.; Cho, K.H. [National Cancer Center, Research Institute and Hospital, Goyang (Korea, Republic of). Proton Therapy Center; Kim, W.C. [Inha Univ. School of Medicine, Incheon (Korea, Republic of). Dept. of Radiation Oncology; Kim, H.J. [Seoul National Univ. College of Medicine (Korea, Republic of). Dept. of Radiation Oncology

    2012-10-15

    Purpose: To compare helical tomotherapy (HT) and conventional intensity-modulated radiotherapy (IMRT) using a variety of dosimetric and radiobiologic indexes in patients with locally advanced non-small cell lung cancer (LA-NSCLC). Patients and methods: A total of 20 patients with LA-NSCLC were enrolled. IMRT plans with 4-6 coplanar beams and HT plans were generated for each patient. Dose distributions and dosimetric indexes for the tumors and critical structures were computed for both plans and compared. Results: Both modalities created highly conformal plans. They did not differ in the volumes of lung exposed to > 20 Gy of radiation. The average mean lung dose, volume receiving {>=} 30 Gy, and volume receiving {>=} 10 Gy in HT planning were 18.3 Gy, 18.5%, and 57.1%, respectively, compared to 19.4 Gy, 25.4%, and 48.9%, respectively, with IMRT (p = 0.004, p < 0.001, and p < 0.001). The differences between HT and IMRT in lung volume receiving {>=} 10-20 Gy increased significantly as the planning target volume (PTV) increased. For 6 patients who had PTV greater than 700 cm{sup 3}, IMRT was superior to HT for 5 patients in terms of lung volume receiving {>=} 5-20 Gy. The integral dose to the entire thorax in HT plans was significantly higher than in IMRT plans. Conclusion: HT gave significantly better control of mean lung dose and volume receiving {>=} 30-40 Gy, whereas IMRT provided better control of the lung volume receiving {>=} 5-15 Gy and the integral dose to entire thorax. In most patients with PTV greater than 700 cm{sup 3}, IMRT was superior to HT in terms of lung volume receiving {>=} 5-20 Gy. It is therefore advised that caution should be exercised when planning LA-NSCLC using HT. (orig.)

  15. MOSFET detectors in quality assurance of tomotherapy treatments.

    Science.gov (United States)

    Cherpak, Amanda; Studinski, Ryan C N; Cygler, Joanna E

    2008-02-01

    The purpose of this work was to characterize metal oxide semiconductor field-effect transistors (MOSFETs) in a 6 MV conventional linac and investigate their use for quality assurance of radiotherapy treatments with a tomotherapy Hi-Art unit. High sensitivity and standard sensitivity MOSFETs were first calibrated and then tested for reproducibility, field size dependence, and accuracy of measuring surface dose in a 6 MV beam as well as in a tomotherapy Hi-Art unit. In vivo measurements were performed on both a RANDO phantom and several head and neck cancer patients treated with tomotherapy and compared to TLD measurements and treatment plan doses to evaluate the performance of MOSFETs in a high gradient radiation field. The average calibration factor found was 0.345+/-2.5%cGy/mV for the high sensitivity MOSFETs tested and 0.901+/-2.4%cGy/mV for the standard sensitivity MOSFETs. MOSFET measured surface doses had an average agreement with ion chamber measurements of 1.55% for the high sensitivity MOSFET and 5.23% for the standard sensitivity MOSFET when averaged over all trials and field sizes tested. No significant dependence on field size was found for the standard sensitivity MOSFETs, however a maximum difference of 5.34% was found for the high sensitivity MOSFET calibration factors in the field sizes tested. Measurements made with MOSFETS on head and neck patients treated on a tomotherapy Hi-Art unit had an average agreement of (3.26+/-0.03)% with TLD measurements, however the average of the absolute difference between the MOSFET measurements and the treatment plan skin doses was (12.2+/-7.5)%. The MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1.4% to 6.6%. Similar results were found from trials using a RANDO phantom. The MOSFETs performed well when used in the tomotherapy Hi-Art unit and did not increase the overall treatment set-up time when used for patient measurements. It was found that MOSFETs

  16. A phase II multi-institutional study assessing simultaneous in-field boost helical tomotherapy for 1-3 brain metastases

    International Nuclear Information System (INIS)

    Rodrigues, George; Yartsev, Slav; Tay, Keng Yeow; Pond, Gregory R; Lagerwaard, Frank; Bauman, Glenn

    2012-01-01

    Our research group has previously published a dosimetric planning study that demonstrated that a 60 Gy/10 fractions intralesional boost with whole-brain radiotherapy (WBRT) to 30 Gy/10 fractions was biologically equivalent with a stereotactic radiosurgery (SRS) boost of 18 Gy/1 fraction with 30 Gy/10 fractions WBRT. Helical tomotherapy (HT) was found to be dosimetrically equivalent to SRS in terms of target coverage and superior to SRS in terms of normal tissue tolerance. A phase I trial has been now completed at our institution with a total of 60 enrolled patients and 48 evaluable patients. The phase II dose has been determined to be the final phase I cohort dose of 60 Gy/10 fractions. The objective of this clinical trial is to subject the final phase I cohort dose to a phase II assessment of the endpoints of overall survival, intracranial control (ICC) and intralesional control (ILC). We hypothesize HT would be considered unsuitable for further study if the median OS for patients treated with the HT SIB technique is degraded by 2 months, or the intracranial progression-free rates (ICC and ILC) are inferior by 10% or greater compared to the expected results with treatment by whole brain plus SRS as defined by the RTOG randomized trial. A sample size of 93 patients was calculated based on these parameters as well as the statistical assumptions of alpha = 0.025 and beta = 0.1 due to multiple statistical testing. Secondary assessments of toxicity, health-related quality-of-life, cognitive changes, and tumor response are also integrated into this research protocol. To summarize, the purpose of this phase II trial is to assess this non-invasive alternative to SRS in terms of central nervous system (CNS) control when compared to SRS historical controls. A follow-up phase III trial may be required depending on the results of this trial in order to definitively assess non-inferiority/superiority of this approach. Ultimately, the purpose of this line of research is to

  17. An automatic contour propagation method to follow parotid gland deformation during head-and-neck cancer tomotherapy

    International Nuclear Information System (INIS)

    Faggiano, E; Scalco, E; Rizzo, G; Fiorino, C; Broggi, S; Cattaneo, M; Maggiulli, E; Calandrino, R; Dell'Oca, I; Di Muzio, N

    2011-01-01

    We developed an efficient technique to auto-propagate parotid gland contours from planning kVCT to daily MVCT images of head-and-neck cancer patients treated with helical tomotherapy. The method deformed a 3D surface mesh constructed from manual kVCT contours by B-spline free-form deformation to generate optimal and smooth contours. Deformation was calculated by elastic image registration between kVCT and MVCT images. Data from ten head-and-neck cancer patients were considered and manual contours by three observers were included in both kVCT and MVCT images. A preliminary inter-observer variability analysis demonstrated the importance of contour propagation in tomotherapy application: a high variability was reported in MVCT parotid volume estimation (p = 0.0176, ANOVA test) and a larger uncertainty of MVCT contouring compared with kVCT was demonstrated by DICE and volume variability indices (Wilcoxon signed rank test, p -4 for both indices). The performance analysis of our method showed no significant differences between automatic and manual contours in terms of volumes (p > 0.05, in a multiple comparison Tukey test), center-of-mass distances (p = 0.3043, ANOVA test), DICE values (p = 0.1672, Wilcoxon signed rank test) and average and maximum symmetric distances (p = 0.2043, p = 0.8228 Wilcoxon signed rank tests). Results suggested that our contour propagation method could successfully substitute human contouring on MVCT images.

  18. An automatic contour propagation method to follow parotid gland deformation during head-and-neck cancer tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Faggiano, E; Scalco, E; Rizzo, G [Istituto di Bioimmagini e Fisiologia Molecolare (IBFM), CNR, Milan (Italy); Fiorino, C; Broggi, S; Cattaneo, M; Maggiulli, E; Calandrino, R [Department of Medical Physics, San Raffaele Scientific Institute, Milan (Italy); Dell' Oca, I; Di Muzio, N, E-mail: fiorino.claudio@hsr.it [Department of Radiotherapy, San Raffaele Scientific Institute, Milan (Italy)

    2011-02-07

    We developed an efficient technique to auto-propagate parotid gland contours from planning kVCT to daily MVCT images of head-and-neck cancer patients treated with helical tomotherapy. The method deformed a 3D surface mesh constructed from manual kVCT contours by B-spline free-form deformation to generate optimal and smooth contours. Deformation was calculated by elastic image registration between kVCT and MVCT images. Data from ten head-and-neck cancer patients were considered and manual contours by three observers were included in both kVCT and MVCT images. A preliminary inter-observer variability analysis demonstrated the importance of contour propagation in tomotherapy application: a high variability was reported in MVCT parotid volume estimation (p = 0.0176, ANOVA test) and a larger uncertainty of MVCT contouring compared with kVCT was demonstrated by DICE and volume variability indices (Wilcoxon signed rank test, p < 10{sup -4} for both indices). The performance analysis of our method showed no significant differences between automatic and manual contours in terms of volumes (p > 0.05, in a multiple comparison Tukey test), center-of-mass distances (p = 0.3043, ANOVA test), DICE values (p = 0.1672, Wilcoxon signed rank test) and average and maximum symmetric distances (p = 0.2043, p = 0.8228 Wilcoxon signed rank tests). Results suggested that our contour propagation method could successfully substitute human contouring on MVCT images.

  19. Evaluation of the optimal combinations of modulation factor and pitch for Helical TomoTherapy plans made with TomoEdge using Pareto optimal fronts.

    Science.gov (United States)

    De Kerf, Geert; Van Gestel, Dirk; Mommaerts, Lobke; Van den Weyngaert, Danielle; Verellen, Dirk

    2015-09-17

    Modulation factor (MF) and pitch have an impact on Helical TomoTherapy (HT) plan quality and HT users mostly use vendor-recommended settings. This study analyses the effect of these two parameters on both plan quality and treatment time for plans made with TomoEdge planning software by using the concept of Pareto optimal fronts. More than 450 plans with different combinations of pitch [0.10-0.50] and MF [1.2-3.0] were produced. These HT plans, with a field width (FW) of 5 cm, were created for five head and neck patients and homogeneity index, conformity index, dose-near-maximum (D2), and dose-near-minimum (D98) were analysed for the planning target volumes, as well as the mean dose and D2 for most critical organs at risk. For every dose metric the median value will be plotted against treatment time. A Pareto-like method is used in the analysis which will show how pitch and MF influence both treatment time and plan quality. For small pitches (≤0.20), MF does not influence treatment time. The contrary is true for larger pitches (≥0.25) as lowering MF will both decrease treatment time and plan quality until maximum gantry speed is reached. At this moment, treatment time is saturated and only plan quality will further decrease. The Pareto front analysis showed optimal combinations of pitch [0.23-0.45] and MF > 2.0 for a FW of 5 cm. Outside this range, plans will become less optimal. As the vendor-recommended settings fall within this range, the use of these settings is validated.

  20. Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT and Arc technique for esophageal carcinoma

    International Nuclear Information System (INIS)

    Martin, Spencer; Chen, Jeff Z.; Rashid Dar, A.; Yartsev, Slav

    2011-01-01

    Purpose: To compare radiotherapy treatment plans for mid- and distal-esophageal cancer with primary involvement of the gastroesophageal (GE) junction using a novel IMRT and Arc technique (IMRT and Arc), helical tomotherapy (HT), and RapidArc (RA1 and RA2). Methods and materials: Eight patients treated on HT for locally advanced esophageal cancer with radical intent were re-planned for RA and IMRT and Arc. RA plans employed single and double arcs (RA1 and RA2, respectively), while IMRT and Arc plans had four fixed-gantry IMRT fields and a conformal arc. Dose-volume histogram statistics, dose uniformity, and dose homogeneity were analyzed to compare treatment plans. Results: RA2 plans showed significant improvement over RA1 plans in terms of OAR dose and PTV dose uniformity and homogeneity. HT plan provided best dose uniformity (p = 0.001) and dose homogeneity (p = 0.002) to planning target volume (PTV), while IMRT and Arc and RA2 plans gave lowest dose to lungs among four radiotherapy techniques with acceptable PTV dose coverage. Mean V 10 of the lungs was significantly reduced by the RA2 plans compared to IMRT and Arc (40.3%, p = 0.001) and HT (66.2%, p 15 of the lungs for the RA2 plans also showed significant improvement over the IMRT and Arc (25.2%, p = 0.042) and HT (34.8%, p = 0.027) techniques. These improvements came at the cost of higher doses to the heart volume compared to HT and IMRT and Arc techniques. Mean lung dose (MLD) for the IMRT and Arc technique (21.2 ± 5.0% of prescription dose) was significantly reduced compared to HT (26.3%, p = 0.004), RA1 (23.3%, p = 0.028), and RA2 (23.2%, p = 0.017) techniques. Conclusion: The IMRT and Arc technique is a good option for treating esophageal cancer with thoracic involvement. It achieved optimal low dose to the lungs and heart with acceptable PTV coverage. HT is a good option for treating esophageal cancer with little thoracic involvement as it achieves superior dose conformality and uniformity. The RA2

  1. Feasibility of tomotherapy for Graves' ophthalmopathy. Dosimetry comparison with conventional radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Nam P.; Krafft, Shane P. [Arizona Univ., Tucson, AZ (United States). Dept. of Radiation Oncology; Vos, Paul [East Carolina Univ., Greenville, NC (US). Dept. of Biostatistics] (and others)

    2011-09-15

    To compare the dosimetry of tomotherapy and the conventional half-beam technique (HBT) or non-split beam technique (NSBT) for target coverage and radiation dose to the lacrimal glands and lens. A retrospective review of 7 patients with Graves' ophthalmopathy who had radiotherapy because of disease progression on high steroid dose is reported: 3 patients were treated with tomotherapy and 4 patients with HBT. Compared to HBT, tomotherapy may provide better target coverage and significant reduction of radiation dose to the lacrimal glands and a higher dose to the lens. The NSBT improved target coverage but resulted in significantly higher doses to the lens and lacrimal glands. Tomotherapy may provide better coverage of the target volume and may be more effective in reducing severe exophthalmos compared to the conventional radiotherapy technique. (orig.)

  2. Dosimetric selection for helical tomotherapy based stereotactic ablative radiotherapy for early-stage non-small cell lung cancer or lung metastases.

    Directory of Open Access Journals (Sweden)

    Alexander Chi

    Full Text Available BACKGROUND: No selection criteria for helical tomotherapy (HT based stereotactic ablative radiotherapy (SABR to treat early stage non-small cell lung cancer (NSCLC or solitary lung metastases has been established. In this study, we investigate the dosimetric selection criteria for HT based SABR delivering 70 Gy in 10 fractions to avoid severe toxicity in the treatment of centrally located lesions when adequate target dose coverage is desired. MATERIALS AND METHODS: 78 HT-SABR plans for solitary lung lesions were created to prescribe 70 Gy in 10 fractions to the planning target volume (PTV. The PTV was set to have ≥95% PTV receiving 70 Gy in each case. The cases for which dose constraints for ≥1 OAR could not be met without compromising the target dose coverage were compared with cases for which all target and OAR dose constraints were met. RESULTS: There were 23 central lesions for which OAR dose constraints could not be met without compromising PTV dose coverage. Comparing to cases for which optimal HT-based SABR plans were generated, they were associated with larger tumor size (5.72±1.96 cm vs. 3.74±1.49 cm, p<0.0001, higher lung dose, increased number of immediately adjacent OARs ( 3.45±1.34 vs. 1.66±0.81, p<0.0001, and shorter distance to the closest OARs (GTV: 0.26±0.22 cm vs. 0.88±0.54 cm, p<0.0001; PTV 0.19±0.18 cm vs. 0.48±0.36 cm, p = 0.0001. CONCLUSION: Delivery of 70 Gy in 10 fractions with HT to meet all the given OAR and PTV dose constraints are most likely when the following parameters are met: lung lesions ≤3.78 cm (11.98 cc, ≤2 immediately adjacent OARs which are ≥0.45 cm from the gross lesion and ≥0.21 cm from the PTV.

  3. Dosimetric comparison of helical tomotherapy, intensity-modulated radiation therapy, volumetric-modulated arc therapy, and 3-dimensional conformal therapy for the treatment of T1N0 glottic cancer

    International Nuclear Information System (INIS)

    Ekici, Kemal; Pepele, Eda K.; Yaprak, Bahaddin; Temelli, Oztun; Eraslan, Aysun F.; Kucuk, Nadir; Altınok, Ayse Y.; Sut, Pelin A.; Alpak, Ozlem D.; Colak, Cemil; Mayadagli, Alpaslan

    2016-01-01

    Various radiotherapy planning methods for T1N0 laryngeal cancer have been proposed to decrease normal tissue toxicity. We compare helical tomotherapy (HT), linac-based intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and 3-D conformal radiotherapy (3D-CRT) techniques for T1N0 laryngeal cancer. Overall, 10 patients with T1N0 laryngeal cancer were selected and evaluated. Furthermore, 10 radiotherapy treatment plans have been created for all 10 patients, including HT, IMRT, VMAT, and 3D-CRT. IMRT, VMAT, and HT plans vs 3D-CRT plans consistently provided superior planning target volume (PTV) coverage. Similar target coverage was observed between the 3 IMRT modalities. Compared with 3D-CRT, IMRT, HT, and VMAT significantly reduced the mean dose to the carotid arteries. VMAT resulted in the lowest mean dose to the submandibular and thyroid glands. Compared with 3D-CRT, IMRT, HT, and VMAT significantly increased the maximum dose to the spinal cord It was observed that the 3 IMRT modalities studied showed superior target coverage with less variation between each plan in comparison with 3D-CRT. The 3D-CRT plans performed better at the D max of the spinal cord. Clinical investigation is warranted to determine if these treatment approaches would translate into a reduction in radiation therapy–induced toxicities.

  4. Three-dimensional conformal radiation therapy: the tomo-therapy approach

    International Nuclear Information System (INIS)

    Linthout, N.; Verellen, D.; Coninck, P. de; Bel, A.; Storme, G.

    2000-01-01

    Conformal radiation therapy allows the possibility of delivering high doses at the tumor volume whilst limiting the dose to the surrounding tissues and diminishing the secondary effects. With the example of the conformal radiation therapy used at the AZ VU8 (3DCRT and tomo-therapy), two treatment plans of a left ethmoid carcinoma will be evaluated and discussed in detail. The treatment of ethmoid cancer is technically difficult for both radiation therapy and surgery because of the anatomic constraints and patterns of local spread. A radiation therapy is scheduled to be delivered after surgical resection of the tumor. The treatment plan for the radiation therapy was calculated on a three-dimensional (3D) treatment planning system based on virtual simulation with a beam's eye view: George Sherouse's Gratis. An effort was made to make the plan as conformal and as homogeneous as possible to deliver a dose of 66 Gy in 33 fractions at the tumor bed with a maximum dose of 56 Gy to the right optic nerve and the chiasma. To establish the clinical utility and potential advantages of tomo-therapy over 3DCRT for ethmoid carcinoma, the treatment of this patient was also planned with Peacock Plant. For both treatment plans the isodose distributions and cumulative dose volume histograms (CDVH) were computed. Superimposing the CDVHs yielded similar curves for the target and an obvious improvement for organs at risk such as the chiasma, brainstem and the left eye when applying tomo-therapy. These results have also been reflected in the tumor control probabilities (equal for both plans) and the normal tissue complication probabilities (NTCP), yielding significant reductions in NTCP for tomo-therapy. The probability of uncomplicated tumor control was 52.7% for tomo-therapy against 38.3% for 3DCRT. (authors)

  5. A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer

    International Nuclear Information System (INIS)

    Chitapanarux, Imjai; Tharavichitkul, Ekkasit; Nobnop, Wannapa; Wanwilairat, Somsak; Vongtama, Roy; Traisathit, Patrinee

    2015-01-01

    The aim of this study was to compare the dosimetric parameters of whole-pelvis radiotherapy (WPRT) for cervical cancer between step-and-shoot IMRT (SaS-IMRT) and Helical Tomotherapy TM (HT). Retrospective analysis was performed on 20 cervical cancer patients who received WPRT in our center between January 2011 and January 2014. SaS-IMRT and HT treatment plans were generated for each patient. The dosimetric values for target coverage and organ-at-risk (OAR) sparing were compared according to the criteria of the International Commission on Radiation Units and Measurements 83 (ICRU 83) guidelines. Differences in beam-on time (BOT) were also compared. All the PTV dosimetric parameters (D5%, D50% and D95%) for the HT plan were (statistically significantly) of better quality than those for the SaS-IMRT plan (P-value < 0.001 in all respects). HT was also significantly more accurate than SaS-IMRT with respect to the D98% and Dmean of the CTV (P-values of 0.008 and <0.001, respectively). The median Conformity Index (CI) did not differ between the two plans (P-value = 0.057). However, the Uniformity Index for HT was significantly better than that for SaS-IMRT (P-value < 0.001). The median of D50% for the bladder, rectum and small bowel were significantly lower in HT planning than SaS-IMRT (P-value < 0.001). For D2%, we found that HT provided better sparing to the rectum and bladder (P-value < 0.001). However, the median of D2% for the small bowel was comparable for both plans. The median of Dmax of the head of the left femur was significantly lower in the HT plan, but this did not apply for the head of the right femur. BOT for HT was significantly shorter than for SaS-IMRT (P-value < 0.001). HT provided highly accurate plans, with more homogeneous PTV coverage and superior sparing of OARs than SaS-IMRT. In addition, HT enabled a shorter delivery time than SaS-IMRT. (author)

  6. Dosimetric Comparison of 6 MV and 15 MV Single Arc Rapidarc to Helical TomoTherapy for the Treatment of Pancreatic Cancer

    International Nuclear Information System (INIS)

    Cai Jing; Yue Jinbo; McLawhorn, Robert; Yang Wensha; Wijesooriya, Krishni; Dunlap, Neal E.; Sheng Ke; Yin Fangfang; Benedict, Stanley H.

    2011-01-01

    We conducted a planning study to compare Varian's RapidArc (RA) and helical TomoTherapy (HT) for the treatment of pancreatic cancer. Three intensity-modulated radiotherapy (IMRT) plans were generated for 8 patients with pancreatic cancer: one using HT with 6-MV beam (Plan HT6 ), one using single-arc RA with 6-MV beam (Plan RA6 ), and one using single-arc RA with 15-MV beam (Plan RA15 ). Dosimetric indices including high/low conformality index (CI 100% /CI 50% ), heterogeneity index (HI), monitor units (MUs), and doses to organs at risk (OARs) were compared. The mean CI 100% was statistically equivalent with respect to the 2 treatment techniques, as well as beam energy (0.99, 1.01, and 1.02 for Plan HT6 , Plan RA6 , and Plan RA156, respectively). The CI 50% and HI were improved in both RA plans over the HT plan. The RA plans significantly reduced MU (MU RA6 = 697, MU RA15 = 548) compared with HT (MU HT6 = 6177, p = 0.008 in both cases). The mean maximum cord dose was decreased from 29.6 Gy in Plan H T6 to 21.6 Gy (p = 0.05) in Plan RA6 and 21.7 Gy (p = 0.04) in Plan RA15 . The mean bowel dose decreased from 17.2 Gy in Plan HT6 to 15.2 Gy (p = 0.03) in Plan RA6 and 15.0 Gy (p = 0.03) Plan RA15 . The mean liver dose decreased from 8.4 Gy in Plan HT6 to 6.3 Gy (p = 0.04) in Plan RA6 and 6.2 Gy in Plan RA15 . Variations of the mean dose to the duodenum, kidneys, and stomach were statistically insignificant. RA and HT can both deliver conformal dose distributions to target volumes while limiting the dose to surrounding OARs in the treatment of pancreatic cancer. Dosimetric advantages might be gained by using RA over HT by reducing the dose to OARs and total MUs used for treatment.

  7. Rapid Arc, helical tomotherapy, sliding window intensity modulated radiotherapy and three dimensional conformal radiation for localized prostate cancer: A dosimetric comparison

    Directory of Open Access Journals (Sweden)

    Rajesh A Kinhikar

    2014-01-01

    Full Text Available Objective: The objective of this study was to investigate the potential role of RapidArc (RA compared with helical tomotherapy (HT, sliding window intensity modulated radiotherapy (SW IMRT and three-dimensional conformal radiation therapy (3D CRT for localized prostate cancer. Materials and Methods: Prescription doses ranged from 60 Gy to planning target volume (PTV and 66.25 Gy for clinical target volume prostate (CTV-P over 25-30 fractions. PTV and CTV-P coverage were evaluated by conformity index (CI and homogeneity index (HI. Organ sparing comparison was done with mean doses to rectum and bladder. Results: CI 95 were 1.0 ± 0.01 (RA, 0.99 ± 0.01 (HT, 0.97 ± 0.02 (IMRT, 0.98 ± 0.02 (3D CRT for PTV and 1.0 ± 0.00 (RA, HT, SW IMRT and 3D CRT for CTV-P. HI was 0.11 ± 0.03 (RA, 0.16 ± 0.08 (HT, 0.12 ± 0.03 (IMRT, 0.06 ± 0.01 (3D CRT for PTV and 0.03 ± 0.00 (RA, 0.05 ± 0.01 (HT, 0.03 ± 0.01 (SW IMRT and 3D CRT for CTV-P. Mean dose to bladder were 23.68 ± 13.23 Gy (RA, 24.55 ± 12.51 Gy (HT, 19.82 ± 11.61 Gy (IMRT and 23.56 ± 12.81 Gy (3D CRT, whereas mean dose to rectum was 36.85 ± 12.92 Gy (RA, 33.18 ± 11.12 Gy (HT, IMRT and 38.67 ± 12.84 Gy (3D CRT. Conclusion: All studied intensity-modulated techniques yield treatment plans of significantly improved quality when compared with 3D CRT, with HT providing best organs at risk sparing and RA being the most efficient treatment option, reducing treatment time to 1.45-3.7 min and monitor unit to <400 for a 2 Gy fraction.

  8. Application of failure mode and effects analysis (FMEA) to pretreatment phases in tomotherapy.

    Science.gov (United States)

    Broggi, Sara; Cantone, Marie Claire; Chiara, Anna; Di Muzio, Nadia; Longobardi, Barbara; Mangili, Paola; Veronese, Ivan

    2013-09-06

    The aim of this paper was the application of the failure mode and effects analysis (FMEA) approach to assess the risks for patients undergoing radiotherapy treatments performed by means of a helical tomotherapy unit. FMEA was applied to the preplanning imaging, volume determination, and treatment planning stages of the tomotherapy process and consisted of three steps: 1) identification of the involved subprocesses; 2) identification and ranking of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system; and 3) identification of additional safety measures to be proposed for process quality and safety improvement. RPN upper threshold for little concern of risk was set at 125. A total of 74 failure modes were identified: 38 in the stage of preplanning imaging and volume determination, and 36 in the stage of planning. The threshold of 125 for RPN was exceeded in four cases: one case only in the phase of preplanning imaging and volume determination, and three cases in the stage of planning. The most critical failures appeared related to (i) the wrong or missing definition and contouring of the overlapping regions, (ii) the wrong assignment of the overlap priority to each anatomical structure, (iii) the wrong choice of the computed tomography calibration curve for dose calculation, and (iv) the wrong (or not performed) choice of the number of fractions in the planning station. On the basis of these findings, in addition to the safety strategies already adopted in the clinical practice, novel solutions have been proposed for mitigating the risk of these failures and to increase patient safety.

  9. Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

    International Nuclear Information System (INIS)

    Yip, Ho Yin; Mui, Wing Lun A.; Lee, Joseph W.Y.; Fung, Winky Wing Ki; Chan, Jocelyn M.T.; Chiu, G.; Law, Maria Y.Y.

    2013-01-01

    Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time

  10. Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Yip, Ho Yin, E-mail: hoyinyip@yahoo.com.hk [Department of Radiotherapy, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China); Mui, Wing Lun A.; Lee, Joseph W.Y.; Fung, Winky Wing Ki; Chan, Jocelyn M.T.; Chiu, G. [Department of Radiotherapy, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China); Law, Maria Y.Y. [Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China)

    2013-07-01

    Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time.

  11. Pelvic nodal dose escalation with prostate hypofractionation using conformal avoidance defined (H-CAD) intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Hong, Theodore S.; Tome, Wolfgang A.; Jaradat, Hazim; Raisbeck, Bridget M.; Ritter, Mark A.

    2006-01-01

    The management of prostate cancer patients with a significant risk of pelvic lymph node involvement is controversial. Both whole pelvis radiotherapy and dose escalation to the prostate have been linked to improved outcome in such patients, but it is unclear whether conventional whole pelvis doses of only 45-50 Gy are optimal for ultimate nodal control. The purpose of this study is to examine the dosimetric and clinical feasibility of combining prostate dose escalation via hypofractionation with conformal avoidance-based IMRT (H-CAD) dose escalation to the pelvic lymph nodes. One conformal avoidance and one conventional plan were generated for each of eight patients. Conformal avoidance-based IMRT plans were generated that specifically excluded bowel, rectum, and bladder. The prostate and lower seminal vesicles (PTV 70) were planned to receive 70 Gy in 2.5 Gy/fraction while the pelvic lymph nodes (PTV 56) were to concurrently receive 56 Gy in 2 Gy/fraction. The volume of small bowel receiving >45 Gy was restricted to 300 ml or less. These conformal avoidance plans were delivered using helical tomotherapy or LINAC-based IMRT with daily imaging localization. All patients received neoadjuvant and concurrent androgen deprivation with a planned total of two years. The conventional, sequential plans created for comparison purposes for all patients consisted of a conventional 4-field pelvic box prescribed to 50.4 Gy (1.8 Gy/fraction) followed by an IMRT boost to the prostate of 25.2 Gy (1.8 Gy/fraction) yielding a final prostate dose of 75.6 Gy. For all plans, the prescription dose was to cover the target structure. Equivalent uniform dose (EUD) analyses were performed on all targets and dose-volume histograms (DVH) were displayed in terms of both physical and normalized total dose (NTD), i.e. dose in 2 Gy fraction equivalents. H-CAD IMRT plans were created for and delivered to all eight patients. Analysis of the H-CAD plans demonstrates prescription dose coverage of >95

  12. Monte Carlo simulation of the Tomotherapy treatment unit in the static mode using MC HAMMER, a Monte Carlo tool dedicated to Tomotherapy

    International Nuclear Information System (INIS)

    Sterpin, E; Tomsej, M; Cravens, B; Salvat, F; Ruchala, K; Olivera, G H; Vynckier, S

    2007-01-01

    Helical tomotherapy (HT) is designed to deliver highly modulated IMRT treatments. The concept of HT provides new challenges in MC simulation, because simultaneous movement of the gantry, the couch and the multi-leaf collimator (MLC) must be simulated accurately. However, before accounting for gantry, couch movement and multileaf collimator configurations, high accuracy must be achieved while simulating open static fields (1 x 40, 2.5 x 40 and 5 x 40 cm 2 ). This is performed using MC HAMMER, which is a graphical user interface allowing MC simulation using PENELOPE for various configurations of HT. Since the geometry of the different elements and materials involved in the beam generation are precisely known and defined, the only parameters that need to be tuned on are therefore electron source spot size and electron energy. Beyond the build up region, good agreement (2%/1mm) is achieved for all the field sizes between measurements (ion chamber) and simulations with an electron source energy set to 5.5 MeV. The electron source spot size is modelled as a gaussian distribution with full width half maximum equal to 1.4 mm. This value was chosen to match measured and calculated penumbras in the longitudinal direction

  13. SU-E-T-485: Investigation of a Synthetic Diamond Detector for Tomotherapy Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Knill, C; Nalichowski, A; Halford, R [Karmanos Cancer Institute, Detroit, MI (United States); Zakjevskii, V; Zhuang, L [Wayne State University School of Medicine, Detroit, MI (United States); Snyder, M; Burmeister, J [Karmanos Cancer Institute, Detroit, MI (United States); Wayne State University School of Medicine, Detroit, MI (United States)

    2014-06-01

    Purpose: Tomotherapy treatments are characterized by rotational deliveries of flattening-filter free fields resulting in high-gradient dose distributions. Small volume, rotationally independent detectors are needed for accurate dosimetry. PTWs microDiamond detector, with its small sensitive volume (0.004mm{sup 3}), could potentially be an ideal detector for Tomotherapy. The microDiamond detector was tested against a small volume Exradin A1SL ion chamber for Tomotherapy open-field and IMRT commissioning measurements. Methods: Custom detector holders were fabricated to allow A1SL and microDiamond measurements in the Tomotherapy Cheese phantom and a square solid water phantom. The microDiamond rotational dependence within the Tomotherapy phantom was tested by incrementally rotating the detector in between static-gantry angle Tomotherapy irradiations. Longitudinal Tomotherapy profiles, for all field sizes, were measured with the microDiamond and A1SL detectors at 1.5cm depth in the square phantom, and compared to film. Detector axes were aligned parallel to table motion. Per TG-119 recommendations, both detectors were calibrated to known doses in phantoms and used to measure high-dose points in TG-119 H and N and Prostate plans. The measurements were compared to the treatment planning system and subsequently compared to published TG-119 confidence limits. Results: The microDiamond angular dependence was less than 0.5%. The average difference between the detectors and film-measured longitudinal profile 80–20% penumbras were 0.03+/-0.04mm and 1.36+/-0.22mm for the microDiamond and A1SL, respectively. The average difference between the detector and filmmeasured field sizes were 0.07+/-0.01mm and 0.09+/-0.02mm for the microDiamond and A1SL, respectively. The measured confidence limits were 0.023 and 0.015 for microDiamond and A1SL, respectively. TG-119 reported a confidence limit of 0.034. Conclusion: The microDiamond measured open-field longitudinal Tomotherapy profiles

  14. Encouraging Early Clinical Outcomes With Helical Tomotherapy-Based Image-Guided Intensity-Modulated Radiation Therapy for Residual, Recurrent, and/or Progressive Benign/Low-Grade Intracranial Tumors: A Comprehensive Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Tejpal [Department of Radiation Oncology, ACTREC/TMH, Tata Memorial Centre, Kharghar, Navi Mumbai (India); Wadasadawala, Tabassum; Master, Zubin; Phurailatpam, Reena; Pai-Shetty, Rajershi; Jalali, Rakesh [Department of Radiation Oncology, ACTREC/TMH, Tata Memorial Centre, Kharghar, Navi Mumbai (India)

    2012-02-01

    Purpose: To report early clinical outcomes of helical tomotherapy (HT)-based image-guided intensity-modulated radiation therapy (IMRT) in brain tumors of varying shape, size, and location. Materials and Methods: Patients with residual, recurrent, and/or progressive low-grade intracranial and skull-base tumors were treated on a prospective protocol of HT-based IMRT and followed clinicoradiologically. Standardized metrics were used for plan evaluation and outcome analysis. Results: Twenty-seven patients with 30 lesions were treated to a median radiotherapy dose of 54 Gy in 30 fractions. All HT plans resulted in excellent target volume coverage with steep dose-gradients. The mean (standard deviation) dose homogeneity index and conformity index was 0.07 (0.05) and 0.71 (0.08) respectively. At first response assessment, 20 of 30 lesions were stable, whereas 9 showed partial regression. One patient with a recurrent clival chordoma though neurologically stable showed imaging-defined progression, whereas another patient with stable disease on serial imaging had sustained neurologic worsening. With a median follow-up of 19 months (interquartile range, 11-26 months), the 2-year clinicoradiological progression-free survival and overall survival was 93.3% and 100% respectively. Conclusions: Careful selection of radiotherapy technique is warranted for benign/low-grade brain tumors to achieve durable local control with minimum long-term morbidity. Large or complex-shaped tumors benefit most from IMRT. Our early clinical experience of HT-based IMRT for brain tumors has been encouraging.

  15. Bowel sparing in pediatric cranio-spinal radiotherapy: a comparison of combined electron and photon and helical TomoTherapy techniques to a standard photon method

    International Nuclear Information System (INIS)

    Harron, Elizabeth; Lewis, Joanne

    2012-01-01

    The aim of this study was to compare the dose to organs at risk (OARs) from different craniospinal radiotherapy treatment approaches available at the Northern Centre for Cancer Care (NCCC), with a particular emphasis on sparing the bowel. Method: Treatment plans were produced for a pediatric medulloblastoma patient with inflammatory bowel disease using 3D conformal 6-MV photons (3DCP), combined 3D 6-MV photons and 18-MeV electrons (3DPE), and helical photon TomoTherapy (HT). The 3DPE plan was a modification of the standard 3DCP technique, using electrons to treat the spine inferior to the level of the diaphragm. The plans were compared in terms of the dose-volume data to OARs and the nontumor integral dose. Results: The 3DPE plan was found to give the lowest dose to the bowel and the lowest nontumor integral dose of the 3 techniques. However, the coverage of the spine planning target volume (PTV) was least homogeneous using this technique, with only 74.6% of the PTV covered by 95% of the prescribed dose. HT was able to achieve the best coverage of the PTVs (99.0% of the whole-brain PTV and 93.1% of the spine PTV received 95% of the prescribed dose), but delivered a significantly higher integral dose. HT was able to spare the heart, thyroid, and eyes better than the linac-based techniques, but other OARs received a higher dose. Conclusions: Use of electrons was the best method for reducing the dose to the bowel and the integral dose, at the expense of compromised spine PTV coverage. For some patients, HT may be a viable method of improving dose homogeneity and reducing selected OAR doses.

  16. Tomotherapy for prostate adenocarcinoma: A report on acute toxicity

    International Nuclear Information System (INIS)

    Keiler, Louis; Dobbins, Donald; Kulasekere, Ravi; Einstein, Douglas

    2007-01-01

    Background and purpose: To analyze the impact of Tomotherapy (TOMO) intensity modulated radiotherapy (IMRT) on acute gastrointestinal (GI) and genitourinary (GU) toxicity in prostate cancer. Materials and methods: The records of 55 consecutively treated TOMO patients were reviewed. Additionally a well-matched group of 43 patients treated with LINAC-based step and shoot IMRT (LINAC) was identified. Acute toxicity was scored according to Radiation Therapy Oncology Group acute toxicity criterion. Results: The grade 2-3 acute GU toxicity rates for the TOMO vs. LINAC groups were 51% vs. 28% (p = 0.001). Acute grade 2 GI toxicity was 25% vs. 40% (p = 0.024), with no grade 3 GI toxicity in either group. In univariate analysis, androgen deprivation, prostate volume, pre-treatment urinary toxicity, and prostate dose homogeneity correlated with acute GI and GU toxicity. With multivariate analysis use of Tomotherapy, median bladder dose and bladder dose homogeneity remained significantly correlated with GU toxicity. Conclusions: Acute GI toxicity for prostate cancer is improved with Tomotherapy at a cost of increased acute GU toxicity possibly due to differences in bladder and prostate dose distribution

  17. Real-time motion-adaptive-optimization (MAO) in TomoTherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lu Weiguo; Chen Mingli; Ruchala, Kenneth J; Chen Quan; Olivera, Gustavo H [TomoTherapy Inc., 1240 Deming Way, Madison, WI (United States); Langen, Katja M; Kupelian, Patrick A [MD Anderson Cancer Center-Orlando, Orlando, FL (United States)], E-mail: wlu@tomotherapy.com

    2009-07-21

    IMRT delivery follows a planned leaf sequence, which is optimized before treatment delivery. However, it is hard to model real-time variations, such as respiration, in the planning procedure. In this paper, we propose a negative feedback system of IMRT delivery that incorporates real-time optimization to account for intra-fraction motion. Specifically, we developed a feasible workflow of real-time motion-adaptive-optimization (MAO) for TomoTherapy delivery. TomoTherapy delivery is characterized by thousands of projections with a fast projection rate and ultra-fast binary leaf motion. The technique of MAO-guided delivery calculates (i) the motion-encoded dose that has been delivered up to any given projection during the delivery and (ii) the future dose that will be delivered based on the estimated motion probability and future fluence map. These two pieces of information are then used to optimize the leaf open time of the upcoming projection right before its delivery. It consists of several real-time procedures, including 'motion detection and prediction', 'delivered dose accumulation', 'future dose estimation' and 'projection optimization'. Real-time MAO requires that all procedures are executed in time less than the duration of a projection. We implemented and tested this technique using a TomoTherapy (registered) research system. The MAO calculation took about 100 ms per projection. We calculated and compared MAO-guided delivery with two other types of delivery, motion-without-compensation delivery (MD) and static delivery (SD), using simulated 1D cases, real TomoTherapy plans and the motion traces from clinical lung and prostate patients. The results showed that the proposed technique effectively compensated for motion errors of all test cases. Dose distributions and DVHs of MAO-guided delivery approached those of SD, for regular and irregular respiration with a peak-to-peak amplitude of 3 cm, and for medium and large

  18. Real-time motion-adaptive-optimization (MAO) in TomoTherapy

    International Nuclear Information System (INIS)

    Lu Weiguo; Chen Mingli; Ruchala, Kenneth J; Chen Quan; Olivera, Gustavo H; Langen, Katja M; Kupelian, Patrick A

    2009-01-01

    IMRT delivery follows a planned leaf sequence, which is optimized before treatment delivery. However, it is hard to model real-time variations, such as respiration, in the planning procedure. In this paper, we propose a negative feedback system of IMRT delivery that incorporates real-time optimization to account for intra-fraction motion. Specifically, we developed a feasible workflow of real-time motion-adaptive-optimization (MAO) for TomoTherapy delivery. TomoTherapy delivery is characterized by thousands of projections with a fast projection rate and ultra-fast binary leaf motion. The technique of MAO-guided delivery calculates (i) the motion-encoded dose that has been delivered up to any given projection during the delivery and (ii) the future dose that will be delivered based on the estimated motion probability and future fluence map. These two pieces of information are then used to optimize the leaf open time of the upcoming projection right before its delivery. It consists of several real-time procedures, including 'motion detection and prediction', 'delivered dose accumulation', 'future dose estimation' and 'projection optimization'. Real-time MAO requires that all procedures are executed in time less than the duration of a projection. We implemented and tested this technique using a TomoTherapy (registered) research system. The MAO calculation took about 100 ms per projection. We calculated and compared MAO-guided delivery with two other types of delivery, motion-without-compensation delivery (MD) and static delivery (SD), using simulated 1D cases, real TomoTherapy plans and the motion traces from clinical lung and prostate patients. The results showed that the proposed technique effectively compensated for motion errors of all test cases. Dose distributions and DVHs of MAO-guided delivery approached those of SD, for regular and irregular respiration with a peak-to-peak amplitude of 3 cm, and for medium and large prostate motions. The results conceptually

  19. [Position-checking by imaging embarked there tomotherapy and the delegation to the radiology technician].

    Science.gov (United States)

    Autret, A; Choupeaux, D; Le Mée, M

    2016-10-01

    Tomotherapy is a technique of IMRT and IGRT using a linear accelerator and a helical CT-scanner. To reach this targeting of precision, the repositioning of the patient is essential. The use of a contention adapted according to the location of the disease and the morphology of the patient is necessary for the safety of this one and the treatment. Once the patient positioned on the reference table, technicians of imager's team check by the acquisition of helical imagery with the reference CT-scanner the position of the patient, the zone of the PTV and healthy organs in the protected surroundings. At first, adjustment will be made automatically on three planes of the space (axial, sagittal, frontal) and three rotations (pitch, roll and yaw) by the device of treatment, then the technicians of imagery will bring a modification of these recalls manually. After validation, the processing will then be made in complete safety for the patient and the nursing. This check by MVCT is daily before every session of processing. It is made by the technicians of imagery. The radiation oncologist confirms the images at j0, then controls once a week MVCT. Traceability in the file of the patient of the various marks (osseous and\\or soft tissue) necessary for the daily gaps will be noted by this one to delegate to the technicians of imagery the validation of the MVCT before every session. Copyright © 2016. Published by Elsevier SAS.

  20. Can We Spare the Pancreas and Other Abdominal Organs at Risk? A Comparison of Conformal Radiotherapy, Helical Tomotherapy and Proton Beam Therapy in Pediatric Irradiation.

    Science.gov (United States)

    Jouglar, Emmanuel; Wagner, Antoine; Delpon, Grégory; Campion, Loïc; Meingan, Philippe; Bernier, Valérie; Demoor-Goldschmidt, Charlotte; Mahé, Marc-André; Lacornerie, Thomas; Supiot, Stéphane

    2016-01-01

    Late abdominal irradiation toxicity during childhood included renal damage, hepatic toxicity and secondary diabetes mellitus. We compared the potential of conformal radiotherapy (CRT), helical tomotherapy (HT) and proton beam therapy (PBT) to spare the abdominal organs at risk (pancreas, kidneys and liver- OAR) in children undergoing abdominal irradiation. We selected children with abdominal tumors who received more than 10 Gy to the abdomen. Treatment plans were calculated in order to keep the dose to abdominal OAR as low as possible while maintaining the same planned target volume (PTV) coverage. Dosimetric values were compared using the Wilcoxon signed-rank test. The dose distribution of 20 clinical cases with a median age of 8 years (range 1-14) were calculated with different doses to the PTV: 5 medulloblastomas (36 Gy), 3 left-sided and 2 right-sided nephroblastomas (14.4 Gy to the tumor + 10.8 Gy boost to para-aortic lymphnodes), 1 left-sided and 4 right-sided or midline neuroblastomas (21 Gy) and 5 Hodgkin lymphomas (19.8 Gy to the para-aortic lymphnodes and spleen). HT significantly reduced the mean dose to the whole pancreas (WP), the pancreatic tail (PT) and to the ipsilateral kidney compared to CRT. PBT reduced the mean dose to the WP and PT compared to both CRT and HT especially in midline and right-sided tumors. PBT decreased the mean dose to the ispilateral kidney but also to the contralateral kidney and the liver compared to CRT. Low dose to normal tissue was similar or increased with HT whereas integral dose and the volume of normal tissue receiving at least 5 and 10 Gy were reduced with PBT compared to CRT and HT. In children undergoing abdominal irradiation therapy, proton beam therapy reduces the dose to abdominal OAR while sparing normal tissue by limiting low dose irradiation.

  1. Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the hypofractionated treatment of high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Yartsev Slav

    2008-01-01

    Full Text Available Abstract Background To compare two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the setting of hypofractionated high-risk prostate cancer treatment. Methods 3DCRT and dIMRT/Helical Tomotherapy(HT planning with 10 CT datasets was undertaken to deliver 68 Gy in 25 fractions (prostate and simultaneously delivering 45 Gy in 25 fractions (pelvic lymph node targets in a single phase. The paradigms of pelvic vessel targeting (iliac vessels with margin are used to target pelvic nodes and conformal normal tissue avoidance (treated soft tissues of the pelvis while limiting dose to identified pelvic critical structures were assessed compared to 3DCRT controls. Both dIMRT/HT and 3DCRT solutions were compared to each other using repeated measures ANOVA and post-hoc paired t-tests. Results When compared to conformal pelvic vessel targeting, conformal normal tissue avoidance delivered more homogenous PTV delivery (2/2 t-test comparisons; p dose, 1–3 Gy over 5/10 dose points; p Conclusion dIMRT/HT nodal and pelvic targeting is superior to 3DCRT in dose delivery and critical structure sparing in the setting of hypofractionation for high-risk prostate cancer. The pelvic targeting paradigm is a potential solution to deliver highly conformal pelvic radiation treatment in the setting of nodal location uncertainty in prostate cancer and other pelvic malignancies.

  2. PET-guided dose escalation tomotherapy in malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Fodor, Andrei; Dell' Oca, Italo; Pasetti, Marcella; Di Muzio, Nadia Gisella [San Raffaele Scientific Institute, Milan (Italy). Dept. of Radiotherapy; Fiorino, Claudio; Broggi, Sara; Cattaneo, Giovanni Mauro; Calandrino, Riccardo [San Raffaele Scientific Institute, Milan (Italy). Medical Physics; Gianolli, Luigi [San Raffaele Scientific Institute, Milan (Italy). Dept. of Nuclear Medicine

    2011-11-15

    To test the feasibility of salvage radiotherapy using PET-guided helical tomotherapy in patients with progressive malignant pleural mesothelioma (MPM). A group of 12 consecutive MPM patients was treated with 56 Gy/25 fractions to the planning target volume (PTV); FDG-PET/CT simulation was always performed to include all positive lymph nodes and MPM infiltrations. Subsequently, a second group of 12 consecutive patients was treated with the same dose to the whole pleura adding a simultaneous integrated boost of 62.5 Gy to the FDG-PET/CT positive areas (BTV). Good dosimetric results were obtained in both groups. No grade 3 (RTOG/EORTC) acute or late toxicities were reported in the first group, while 3 cases of grade 3 late pneumonitis were registered in the second group: the duration of symptoms was 2-10 weeks. Median overall survival was 8 months (1.2-50.5 months) and 20 months (4.3-33.8 months) from the beginning of radiotherapy, for groups I and II, respectively (p = 0.19). A significant impact on local relapse from radiotherapy was seen (median time to local relapse: 8 vs 17 months; 1-year local relapse-free rate: 16% vs 81%, p = 0.003). The results of this pilot study support the planning of a phase III study of combined sequential chemoradiotherapy with dose escalation to BTV in patients not able to undergo resection. (orig.)

  3. Gynecological applications of helical CT using SmartPrep

    Energy Technology Data Exchange (ETDEWEB)

    Sakurada, Akira; Kakizaki, Dai; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1999-11-01

    SmartPrep is software program for scanning a given region of interest (ROI) at optimal contrast density. An operator can arbitrarily define ROI and preset the CT value at which scanning should be started. After the injection of a contrast medium, system conducts continuous monitoring of the ROI and the operator starts helical scanning of the planned region when the present CT value has been reached. In comparison with conventional helical CT that requires a period of time from the beginning of contrast medium injection to the beginning of scanning, SmartPrep minimizes personal error and better depicts the artery-predominant phase under optimal conditions. In this study we examine the usefulness of contrast-enhanced helical CT using SmartPrep in the evaluation of gynecological disease. When the contrast medium was injected into the dorsal vein of the hand at a rate of 3 ml/sec, strong staining of pelvic arteries was observed in the CT images started at 17 to 23 sec after injection. The early-phase helical CT obtained under these conditions provided good depiction of lesions in cases of placenta accreta and invasive mole, as well as clear demonstration of tumor angiogenesis and evaluation of laterality in cases of cervical cancer. Comparison of the early and delayed phase also facilitated easier evaluation of lymph nodes than conventional comparison of simple and contrast-enhanced CT. The results thus suggest the usefulness of contrast-enhanced helical CT using SmartPrep in gynecology. (author)

  4. Stereotactic radiotherapy using tomotherapy for early-stage non-small cell lung carcinoma: analysis of intrafaction tumour motion

    International Nuclear Information System (INIS)

    Boggs, Drexell Hunter; Feigenberg, Steven; Walter, Robert; Wissing, Dennis; Patel, Bijal; Wu, Terry; Rosen, Lane

    2014-01-01

    Intrafraction tumour motion in helical tomotherapy was investigated by comparing pre- and mid-fraction CT scans in patients with early non-small cell lung carcinoma (NSCLC) to assess the efficacy of a 7-mm margin around gross tumour volumes (GTVs) in stereotactic body radiation therapy (SBRT). Thirty patients with early-stage NSCLC received SBRT in four or five fractions for a total of 141 treatments. A slow positron emission tomography/CT scan was fused with the simulation CT to determine the GTV. A planning target volume was created by placing an isotropic margin of 7mm around the GTV. Data were retrospectively analyzed to assess translational tumour positional changes along the x, y and z axes and vector changes in millimeters from the pretreatment megavoltage (MV)-CT to the mid-fraction MV-CT. Average movements for all 141 treatment days along the x, y and z axes were 0.5±2.3, −0.3±3.0 and 0.9±3.0mm, respectively. Average movements for each patient along the x, y and z axes were 0.5±1.5, −0.2±2.0 and 0.9±1.9mm, respectively. Average vector displacement was 4.3±2.4mm for all treatment days and 4.2±1.7mm for each patient. Of 141 treatments, 137 (97.2%) fell within 7.0mm in all axes. The addition of a 7-mm margin to the GTV for patients receiving SBRT for NSCLC using tomotherapy is adequate to account for tumour movement. Mid-fraction CT scans proved to be valuable in assessing intrafraction tumour motion.

  5. Accuracy of out-of-field dose calculation of tomotherapy and Cyberknife treatment planning systems. A dosimetric study

    International Nuclear Information System (INIS)

    Schneider, Uwe; Hirslanden Medical Center, Aarau; Haelg, Roger A.; Hartmann, Matthias; Mack, Andreas; Storelli, Fabrizio; Besserer, Juergen; Joosten, Andreas; Moeckli, Raphael

    2014-01-01

    Purpose: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. Materials and methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. Results: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40 cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10 cm from the PTV border the Tomotherapy up to 35 cm. Conclusions: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35 cm from the PTV border (for a 390 cm 3 large PTV). (orig.)

  6. Helical CT defecography; La defecografia con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M. [Genua Univ., Genua (Italy). Ist. di Radiologia, Cattedra R; Tornago, S. [Genua Univ. Genua (Italy). 2 Clinica Ortopedica

    1999-11-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases. [Italian] Scopo di questo lavoro e' ricercare un ruolo per la defeco-TC con apparecchiatura elicoidale nello studio delle malattie del pavimento pelvico confrontandola con i risultati consolidati della defecografia tradizionale. Si sono visionati 90 pazienti, 62 femmine e 28 maschi, con eta' compresa tra 24 e 82 anni, con defecografia tradizionale; di questi, 18 casi con diagnosi dubbia sono stati studiati anche con defeco-TC spirale

  7. Analytical model of the binary multileaf collimator of tomotherapy for Monte Carlo simulations

    International Nuclear Information System (INIS)

    Sterpin, E; Vynckier, S; Salvat, F; Olivera, G H

    2008-01-01

    Helical Tomotherapy (HT) delivers intensity-modulated radiotherapy by the means of many configurations of the binary multi-leaf collimator (MLC). The aim of the present study was to devise a method, which we call the 'transfer function' (TF) method, to perform the transport of particles through the MLC much faster than the time consuming Monte Carlo (MC) simulation and with no significant loss of accuracy. The TF method consists of calculating, for each photon in the phase-space file, the attenuation factor for each leaf (up to three) that the photon passes, assuming straight propagation through closed leaves, and storing these factors in a modified phase-space file. To account for the transport through the MLC in a given configuration, the weight of a photon is simply multiplied by the attenuation factors of the leaves that are intersected by the photon ray and are closed. The TF method was combined with the PENELOPE MC code, and validated with measurements for the three static field sizes available (40x5, 40x2.5 and 40x1 cm 2 ) and for some MLC patterns. The TF method allows a large reduction in computation time, without introducing appreciable deviations from the result of full MC simulations

  8. Multi-institutional Feasibility Study of a Fast Patient Localization Method in Total Marrow Irradiation With Helical Tomotherapy: A Global Health Initiative by the International Consortium of Total Marrow Irradiation

    International Nuclear Information System (INIS)

    Takahashi, Yutaka; Vagge, Stefano; Agostinelli, Stefano; Han, Eunyoung; Matulewicz, Lukasz; Schubert, Kai; Chityala, Ravishankar; Ratanatharathorn, Vaneerat; Tournel, Koen; Penagaricano, Jose A.; Florian, Sterzing; Mahe, Marc-Andre; Verneris, Michael R.; Weisdorf, Daniel J.

    2015-01-01

    Purpose: To develop, characterize, and implement a fast patient localization method for total marrow irradiation. Methods and Materials: Topographic images were acquired using megavoltage computed tomography (MVCT) detector data by delivering static orthogonal beams while the couch traversed through the gantry. Geometric and detector response corrections were performed to generate a megavoltage topogram (MVtopo). We also generated kilovoltage topograms (kVtopo) from the projection data of 3-dimensional CT images to reproduce the same geometry as helical tomotherapy. The MVtopo imaging dose and the optimal image acquisition parameters were investigated. A multi-institutional phantom study was performed to verify the image registration uncertainty. Forty-five MVtopo images were acquired and analyzed with in-house image registration software. Results: The smallest jaw size (front and backup jaws of 0) provided the best image contrast and longitudinal resolution. Couch velocity did not affect the image quality or geometric accuracy. The MVtopo dose was less than the MVCT dose. The image registration uncertainty from the multi-institutional study was within 2.8 mm. In patient localization, the differences in calculated couch shift between the registration with MVtopo-kVtopo and MVCT-kVCT images in lateral, cranial–caudal, and vertical directions were 2.2 ± 1.7 mm, 2.6 ± 1.4 mm, and 2.7 ± 1.1 mm, respectively. The imaging time in MVtopo acquisition at the couch speed of 3 cm/s was <1 minute, compared with ≥15 minutes in MVCT for all patients. Conclusion: Whole-body MVtopo imaging could be an effective alternative to time-consuming MVCT for total marrow irradiation patient localization

  9. Poster — Thur Eve — 15: Improvements in the stability of the tomotherapy imaging beam

    Energy Technology Data Exchange (ETDEWEB)

    Belec, J [The Ottawa Hospital Cancer Center, Ontario (Canada)

    2014-08-15

    Use of helical TomoTherapy based MVCT imaging for adaptive planning requires the image values (HU) to remain stable over the course of treatment. In the past, the image value stability was suboptimal, which required frequent change to the image value to density calibration curve to avoid dose errors on the order of 2–4%. The stability of the image values at our center was recently improved by stabilizing the dose rate of the machine (dose control servo) and performing daily MVCT calibration corrections. In this work, we quantify the stability of the image values over treatment time by comparing patient treatment image density derived using MVCT and KVCT. The analysis includes 1) MVCT - KVCT density difference histogram, 2) MVCT vs KVCT density spectrum, 3) multiple average profile density comparison and 4) density difference in homogeneous locations. Over two months, the imaging beam stability was compromised several times due to a combination of target wobbling, spectral calibration, target change and magnetron issues. The stability of the image values were analyzed over the same period. Results show that the impact on the patient dose calculation is 0.7% +− 0.6%.

  10. SU-D-201-03: During-Treatment Delivery Monitoring System for TomoTherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Q; Read, P [University of Virginia, Charlottesville, VA (United States)

    2016-06-15

    Purpose: Multiple error pathways can lead to delivery errors during the treatment course that cannot be caught with pre-treatment QA. While in vivo solutions are being developed for linacs, no such solution exists for tomotherapy. The purpose of this study is to develop a near real-time system for tomotherapy that can monitor the delivery and dose accumulation process during the treatment-delivery, which enable the user to assess the impact of delivery variations and/or errors and to interrupt the treatment if necessary. Methods: A program running on a tomotherapy planning station fetches the raw DAS data during treatment. Exit detector data is extracted as well as output, gantry angle, and other machine parameters. For each sample, the MLC open-close state is determined. The delivered plan is compared with the original plan via a Monte Carlo dose engine which transports fluence deviations from a pre-treatment Monte Carlo run. A report containing the difference in fluence, dose and DVH statistics is created in html format. This process is repeated until the treatment is completed. Results: Since we only need to compute the dose for the difference in fluence for a few projections each time, dose with 2% statistical uncertainty can be computed in less than 1 second on a 4-core cpu. However, the current bottleneck in this near real-time system is the repeated fetching and processing the growing DAS data file throughout the delivery. The frame rate drops from 10Hz at the beginning of treatment to 5Hz after 3 minutes and to 2Hz after 10 minutes. Conclusion: A during-treatment delivery monitor system has been built to monitor tomotherapy treatments. The system improves patient safety by allowing operators to assess the delivery variations and errors during treatment delivery and adopt appropriate actions.

  11. SU-D-201-03: During-Treatment Delivery Monitoring System for TomoTherapy

    International Nuclear Information System (INIS)

    Chen, Q; Read, P

    2016-01-01

    Purpose: Multiple error pathways can lead to delivery errors during the treatment course that cannot be caught with pre-treatment QA. While in vivo solutions are being developed for linacs, no such solution exists for tomotherapy. The purpose of this study is to develop a near real-time system for tomotherapy that can monitor the delivery and dose accumulation process during the treatment-delivery, which enable the user to assess the impact of delivery variations and/or errors and to interrupt the treatment if necessary. Methods: A program running on a tomotherapy planning station fetches the raw DAS data during treatment. Exit detector data is extracted as well as output, gantry angle, and other machine parameters. For each sample, the MLC open-close state is determined. The delivered plan is compared with the original plan via a Monte Carlo dose engine which transports fluence deviations from a pre-treatment Monte Carlo run. A report containing the difference in fluence, dose and DVH statistics is created in html format. This process is repeated until the treatment is completed. Results: Since we only need to compute the dose for the difference in fluence for a few projections each time, dose with 2% statistical uncertainty can be computed in less than 1 second on a 4-core cpu. However, the current bottleneck in this near real-time system is the repeated fetching and processing the growing DAS data file throughout the delivery. The frame rate drops from 10Hz at the beginning of treatment to 5Hz after 3 minutes and to 2Hz after 10 minutes. Conclusion: A during-treatment delivery monitor system has been built to monitor tomotherapy treatments. The system improves patient safety by allowing operators to assess the delivery variations and errors during treatment delivery and adopt appropriate actions.

  12. Helical Tomotherapy for Whole-Brain Irradiation With Integrated Boost to Multiple Brain Metastases: Evaluation of Dose Distribution Characteristics and Comparison With Alternative Techniques

    International Nuclear Information System (INIS)

    Levegrün, Sabine; Pöttgen, Christoph; Wittig, Andrea; Lübcke, Wolfgang; Abu Jawad, Jehad; Stuschke, Martin

    2013-01-01

    Purpose: To quantitatively evaluate dose distribution characteristics achieved with helical tomotherapy (HT) for whole-brain irradiation (WBRT) with integrated boost (IB) to multiple brain metastases in comparison with alternative techniques. Methods and Materials: Dose distributions for 23 patients with 81 metastases treated with WBRT (30 Gy/10 fractions) and IB (50 Gy) were analyzed. The median number of metastases per patient (N mets ) was 3 (range, 2-8). Mean values of the composite planning target volume of all metastases per patient (PTV mets ) and of the individual metastasis planning target volume (PTV ind met ) were 8.7 ± 8.9 cm 3 (range, 1.3-35.5 cm 3 ) and 2.5 ± 4.5 cm 3 (range, 0.19-24.7 cm 3 ), respectively. Dose distributions in PTV mets and PTV ind met were evaluated with respect to dose conformity (conformation number [CN], RTOG conformity index [PITV]), target coverage (TC), and homogeneity (homogeneity index [HI], ratio of maximum dose to prescription dose [MDPD]). The dependence of dose conformity on target size and N mets was investigated. The dose distribution characteristics were benchmarked against alternative irradiation techniques identified in a systematic literature review. Results: Mean ± standard deviation of dose distribution characteristics derived for PTV mets amounted to CN = 0.790 ± 0.101, PITV = 1.161 ± 0.154, TC = 0.95 ± 0.01, HI = 0.142 ± 0.022, and MDPD = 1.147 ± 0.029, respectively, demonstrating high dose conformity with acceptable homogeneity. Corresponding numbers for PTV ind met were CN = 0.708 ± 0.128, PITV = 1.174 ± 0.237, TC = 0.90 ± 0.10, HI = 0.140 ± 0.027, and MDPD = 1.129 ± 0.030, respectively. The target size had a statistically significant influence on dose conformity to PTV mets (CN = 0.737 for PTV mets ≤4.32 cm 3 vs CN = 0.848 for PTV mets >4.32 cm 3 , P=.006), in contrast to N mets . The achieved dose conformity to PTV mets , assessed by both CN and PITV, was in all investigated volume strata

  13. SU-F-T-468: Efficient Scanning Data Analysis for TomoTherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sintay, B; Pearman, K; Maurer, J; Liu, H; Hayes, T; Wiant, D [Cone Health Cancer Center, Greensboro, NC (United States)

    2016-06-15

    Purpose: The standard TomoTherapy 2D scanning system requires manual analysis using spreadsheets or similar software. Manual analysis is time consuming and does not allow efficient use of the medical physicist or timely results that may indicate issues during the acquisition of data. The purpose of this study is to determine if an in-house solution can provide timely analysis of TomoTherapy scan data. Methods: A custom MATLAB program utilizing a streamlined graphical interface was developed to interpret the native scanning data acquired by the TomoTherapy Electrometer Measurement System (TEMS). The gold beam data provided by the manufacturer was used as a baseline for the acquired data. Two separate sets of scan data were used including longitudinal, transverse, and percent depth dose (PDD). The scan data were compared visually in an overlay and analytically for each beam width using the full width half max (FWHM) for longitudinal profiles and difference inside the field core for the transverse profiles as recommended by TG-148. A plot of the PDD percent error at each point along the curve was generated to show agreement. The time to analysis was measured on a laptop running an Intel i5 processor with 8GB of RAM. Results: The software program required on average less than 5 seconds to load and analyze the results. No conversion or reformatting of the data was required. This allowed real-time visualization of the comparison to the gold beam data as well as the parameters recommended by TG-148. The average percent difference was 0.3% for the longitudinal profiles and 0.1% for the transverse profiles. All PDD data was less than 1% different beyond dmax. Conclusion: We have developed a tool to analyze TomoTherapy scan data in real-time. This allows an efficient method to perform beam commissioning, annual QA, and adjust the beam parameters if necessary.

  14. Traumatic injuries: imaging of abdominal and pelvic injuries

    International Nuclear Information System (INIS)

    Weishaupt, Dominik; Grozaj, Ana M.; Willmann, Juergen K.; Roos, Justus E.; Hilfiker, Paul R.; Marincek, Borut

    2002-01-01

    The availability of new imaging modalities has altered the diagnostic approach to patients with abdominal and pelvic trauma. Computed tomography and ultrasound have largely replaced diagnostic peritoneal lavage. Ultrasound is used in most trauma centers as the initial imaging technique for the detection of hemoperitoneum and helps to determine the need for emergency laparotomy. Computed tomography allows for an accurate diagnosis of a wide range of traumatic abdominal and pelvic conditions. The speed of single-detector helical and multi-detector row CT (MDCT) permits a rapid CT examination of the seriously ill patient in the emergency room. In particular, the technology of MDCT permits multiple, sequential CT scans to be quickly obtained in the same patient, which is a great advance in the rapid assessment of the multiple-injured patient. The evolving concepts in trauma care promoting non-operative management of liver and splenic injuries creates the need for follow-up cross-sectional imaging studies in these patients. Computed tomography and, less frequently, MR or ultrasound, are used for this purpose. (orig.)

  15. Traumatic injuries: imaging of abdominal and pelvic injuries

    Energy Technology Data Exchange (ETDEWEB)

    Weishaupt, Dominik; Grozaj, Ana M.; Willmann, Juergen K.; Roos, Justus E.; Hilfiker, Paul R.; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2002-06-01

    The availability of new imaging modalities has altered the diagnostic approach to patients with abdominal and pelvic trauma. Computed tomography and ultrasound have largely replaced diagnostic peritoneal lavage. Ultrasound is used in most trauma centers as the initial imaging technique for the detection of hemoperitoneum and helps to determine the need for emergency laparotomy. Computed tomography allows for an accurate diagnosis of a wide range of traumatic abdominal and pelvic conditions. The speed of single-detector helical and multi-detector row CT (MDCT) permits a rapid CT examination of the seriously ill patient in the emergency room. In particular, the technology of MDCT permits multiple, sequential CT scans to be quickly obtained in the same patient, which is a great advance in the rapid assessment of the multiple-injured patient. The evolving concepts in trauma care promoting non-operative management of liver and splenic injuries creates the need for follow-up cross-sectional imaging studies in these patients. Computed tomography and, less frequently, MR or ultrasound, are used for this purpose. (orig.)

  16. Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A.; Murthy, Vedang; Goel, Vineeta; Tambe, Chandrashekar M.; Dhote, Dipak S.; Deshpande, Deepak D.

    2009-01-01

    The purpose of this work was to estimate skin dose for the patients treated with tomotherapy using metal oxide semiconductor field-effect transistors (MOSFETs) and thermoluminescent dosimeters (TLDs). In vivo measurements were performed for two head and neck patients treated with tomotherapy and compared to TLD measurements. The measurements were subsequently carried out for five days to estimate the inter-fraction deviations in MOSFET measurements. The variation between skin dose measured with MOSFET and TLD for first patient was 2.2%. Similarly, the variation of 2.3% was observed between skin dose measured with MOSFET and TLD for second patient. The tomotherapy treatment planning system overestimated the skin dose as much as by 10-12% when compared to both MOSFET and TLD. However, the MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1% to 1.4%. MOSFETs may be used as a viable dosimeter for measuring skin dose in areas where the treatment planning system may not be accurate.

  17. Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy.

    Science.gov (United States)

    Kinhikar, Rajesh A; Murthy, Vedang; Goel, Vineeta; Tambe, Chandrashekar M; Dhote, Dipak S; Deshpande, Deepak D

    2009-09-01

    The purpose of this work was to estimate skin dose for the patients treated with tomotherapy using metal oxide semiconductor field-effect transistors (MOSFETs) and thermoluminescent dosimeters (TLDs). In vivo measurements were performed for two head and neck patients treated with tomotherapy and compared to TLD measurements. The measurements were subsequently carried out for five days to estimate the inter-fraction deviations in MOSFET measurements. The variation between skin dose measured with MOSFET and TLD for first patient was 2.2%. Similarly, the variation of 2.3% was observed between skin dose measured with MOSFET and TLD for second patient. The tomotherapy treatment planning system overestimated the skin dose as much as by 10-12% when compared to both MOSFET and TLD. However, the MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1% to 1.4%. MOSFETs may be used as a viable dosimeter for measuring skin dose in areas where the treatment planning system may not be accurate.

  18. Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the hypofractionated treatment of high-risk prostate cancer

    International Nuclear Information System (INIS)

    Yuen, Jasper; Rodrigues, George; Trenka, Kristina; Coad, Terry; Yartsev, Slav; D'Souza, David; Lock, Michael; Bauman, Glenn

    2008-01-01

    To compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated high-risk prostate cancer treatment. 3DCRT and dIMRT/Helical Tomotherapy(HT) planning with 10 CT datasets was undertaken to deliver 68 Gy in 25 fractions (prostate) and simultaneously delivering 45 Gy in 25 fractions (pelvic lymph node targets) in a single phase. The paradigms of pelvic vessel targeting (iliac vessels with margin are used to target pelvic nodes) and conformal normal tissue avoidance (treated soft tissues of the pelvis while limiting dose to identified pelvic critical structures) were assessed compared to 3DCRT controls. Both dIMRT/HT and 3DCRT solutions were compared to each other using repeated measures ANOVA and post-hoc paired t-tests. When compared to conformal pelvic vessel targeting, conformal normal tissue avoidance delivered more homogenous PTV delivery (2/2 t-test comparisons; p < 0.001), similar nodal coverage (8/8 t-test comparisons; p = ns), higher and more homogenous pelvic tissue dose (6/6 t-test comparisons; p < 0.03), at the cost of slightly higher critical structure dose (D dose , 1–3 Gy over 5/10 dose points; p < 0.03). The dIMRT/HT approaches were superior to 3DCRT in sparing organs at risk (22/24 t-test comparisons; p < 0.05). dIMRT/HT nodal and pelvic targeting is superior to 3DCRT in dose delivery and critical structure sparing in the setting of hypofractionation for high-risk prostate cancer. The pelvic targeting paradigm is a potential solution to deliver highly conformal pelvic radiation treatment in the setting of nodal location uncertainty in prostate cancer and other pelvic malignancies

  19. Intensity-Modulated Radiotherapy (IMRT) vs Helical Tomotherapy (HT) in Concurrent Chemoradiotherapy (CRT) for Patients with Anal Canal Carcinoma (ACC): an analysis of dose distribution and toxicities

    International Nuclear Information System (INIS)

    Yeung, Rosanna; McConnell, Yarrow; Warkentin, Heather; Graham, Darren; Warkentin, Brad; Joseph, Kurian; Doll, Corinne M

    2015-01-01

    Intensity-modulated radiotherapy (IMRT) and helical tomotherapy (HT) have been adopted for radiotherapy treatment of anal canal carcinoma (ACC) due to better conformality, dose homogeneity and normal-tissue sparing compared to 3D-CRT. To date, only one published study compares dosimetric parameters of IMRT vs HT in ACC, but there are no published data comparing toxicities. Our objectives were to compare dosimetry and toxicities between these modalities. This is a retrospective study of 35 ACC patients treated with radical chemoradiotherapy at two tertiary cancer institutions from 2008–2010. The use of IMRT vs HT was primarily based on center availability. The majority of patients received fluorouracil (5-FU) and 1–2 cycles of mitomycin C (MMC); 2 received 5-FU and cisplatin. Primary tumor and elective nodes were prescribed to ≥54Gy and ≥45Gy, respectively. Patients were grouped into two cohorts: IMRT vs HT. The primary endpoint was a dosimetric comparison between the cohorts; the secondary endpoint was comparison of toxicities. 18 patients were treated with IMRT and 17 with HT. Most IMRT patients received 5-FU and 1 MMC cycle, while most HT patients received 2 MMC cycles (p < 0.01), based on center policy. HT achieved more homogenous coverage of the primary tumor (HT homogeneity and uniformity index 0.14 and 1.02 vs 0.29 and 1.06 for IMRT, p = 0.01 and p < 0.01). Elective nodal coverage did not differ. IMRT achieved better bladder, femoral head and peritoneal space sparing (V30 and V40, p ≤ 0.01), and lower mean skin dose (p < 0.01). HT delivered lower bone marrow (V10, p < 0.01) and external genitalia dose (V20 and V30, p < 0.01). Grade 2+ hematological and non-hematological toxicities were similar. Febrile neutropenia and unscheduled treatment breaks did not differ (both p = 0.13), nor did 3-year overall and disease-free survival (p = 0.13, p = 0.68). Chemoradiotherapy treatment of ACC using IMRT vs HT results in differences in dose homogenity and

  20. Radiobiologic comparison of helical tomotherapy, intensity modulated radiotherapy, and conformal radiotherapy in treating lung cancer accounting for secondary malignancy risks

    Energy Technology Data Exchange (ETDEWEB)

    Komisopoulos, Georgios [Department of Medical Physics, Medical School, University of Patras, Patras (Greece); Mavroidis, Panayiotis, E-mail: mavroidis@uthscsa.edu [Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, San Antonio, TX (United States); Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm (Sweden); Rodriguez, Salvador; Stathakis, Sotirios; Papanikolaou, Nikos [Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, San Antonio, TX (United States); Nikiforidis, Georgios C.; Sakellaropoulos, Georgios C. [Department of Medical Physics, Medical School, University of Patras, Patras (Greece)

    2014-01-01

    The aim of the present study is to examine the importance of using measures to predict the risk of inducing secondary malignancies in association with the clinical effectiveness of treatment plans in terms of tumor control and normal tissue complication probabilities. This is achieved by using radiobiologic parameters and measures, which may provide a closer association between clinical outcome and treatment delivery. Overall, 4 patients having been treated for lung cancer were examined. For each of them, 3 treatment plans were developed based on the helical tomotherapy (HT), multileaf collimator-based intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (CRT) modalities. The different plans were evaluated using the complication-free tumor control probability (p{sub +}), the overall probability of injury (p{sub I}), the overall probability of control/benefit (p{sub B}), and the biologically effective uniform dose (D{sup ¯¯}). These radiobiologic measures were used to develop dose-response curves (p-D{sup ¯¯} diagram), which can help to evaluate different treatment plans when used in conjunction with standard dosimetric criteria. The risks for secondary malignancies in the heart and the contralateral lung were calculated for the 3 radiation modalities based on the corresponding dose-volume histograms (DVHs) of each patient. Regarding the overall evaluation of the different radiation modalities based on the p{sub +} index, the average values of the HT, IMRT, and CRT are 67.3%, 61.2%, and 68.2%, respectively. The corresponding average values of p{sub B} are 75.6%, 70.5%, and 71.0%, respectively, whereas the average values of p{sub I} are 8.3%, 9.3%, and 2.8%, respectively. Among the organs at risk (OARs), lungs show the highest probabilities for complications, which are 7.1%, 8.0%, and 1.3% for the HT, IMRT, and CRT modalities, respectively. Similarly, the biologically effective prescription doses (D{sub B}{sup ¯¯}) for the

  1. Patient Dose From Megavoltage Computed Tomography Imaging

    International Nuclear Information System (INIS)

    Shah, Amish P.; Langen, Katja M.; Ruchala, Kenneth J.; Cox, Andrea; Kupelian, Patrick A.; Meeks, Sanford L.

    2008-01-01

    Purpose: Megavoltage computed tomography (MVCT) can be used daily for imaging with a helical tomotherapy unit for patient alignment before treatment delivery. The purpose of this investigation was to show that the MVCT dose can be computed in phantoms, and further, that the dose can be reported for actual patients from MVCT on a helical tomotherapy unit. Methods and Materials: An MVCT beam model was commissioned and verified through a series of absorbed dose measurements in phantoms. This model was then used to retrospectively calculate the imaging doses to the patients. The MVCT dose was computed for five clinical cases: prostate, breast, head/neck, lung, and craniospinal axis. Results: Validation measurements in phantoms verified that the computed dose can be reported to within 5% of the measured dose delivered at the helical tomotherapy unit. The imaging dose scaled inversely with changes to the CT pitch. Relative to a normal pitch of 2.0, the organ dose can be scaled by 0.67 and 2.0 for scans done with a pitch of 3.0 and 1.0, respectively. Typical doses were in the range of 1.0-2.0 cGy, if imaged with a normal pitch. The maximal organ dose calculated was 3.6 cGy in the neck region of the craniospinal patient, if imaged with a pitch of 1.0. Conclusion: Calculation of the MVCT dose has shown that the typical imaging dose is approximately 1.5 cGy per image. The uniform MVCT dose delivered using helical tomotherapy is greatest when the anatomic thickness is the smallest and the pitch is set to the lowest value

  2. MO-FG-BRA-07: Intrafractional Motion Effect Can Be Minimized in Tomotherapy Stereotactic Body Radiotherapy (SBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Price, A; Chang, S; Matney, J; Wang, A; Lian, J [University of North Carolina, Chapel Hill, NC (United States); Chao, E [Accuray Incorporated, Madison, WI (United States)

    2016-06-15

    Purpose: Tomotherapy has unique challenges in handling intrafractional motion compared to conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data and investigated real time jaw/MLC compensation approaches to minimize the motion-induced dose discrepancy in Tomotherapy SBRT treatment. Methods: Intrafractional motion data recorded in two CyberKnife lung treatment cases through fiducial tracking and two LINAC prostate cases through Calypso tracking were used in this study. For each treatment site, one representative case has an average motion (6mm) and one has a large motion (10mm for lung and 15mm for prostate). The cases were re-planned on Tomotherapy for SBRT. Each case was planned with 3 different jaw settings: 1cm static, 2.5cm dynamic, and 5cm dynamic. 4D dose accumulation software was developed to compute dose with the recorded motions and theoretically compensate motions by modifying original jaw and MLC to track the trajectory of the tumor. Results: PTV coverage in Tomotherapy SBRT for patients with intrafractional motion depends on motion type, amplitude and plan settings. For the prostate patient with large motion, PTV coverage changed from 97.2% (motion-free) to 47.1% (target motion-included), 96.6% to 58.5% and 96.3% to 97.8% for the 1cm static jaw, 2.5cm dynamic jaw and 5cm dynamic jaw setting, respectively. For the lung patient with large motion, PTV coverage discrepancies showed a similar trend of change. When the jaw and MLC compensation program was engaged, the motion compromised PTV coverage was recovered back to >95% for all cases and plans. All organs at risk (OAR) were spared with < 5% increase from original motion-free plans. Conclusion: Tomotherapy SBRT is less motion-impacted when 5cm dynamic jaw is used. Once the motion pattern is known, the jaw and MLC compensation program can largely minimize the compromised target coverage and OAR sparing.

  3. MO-FG-BRA-07: Intrafractional Motion Effect Can Be Minimized in Tomotherapy Stereotactic Body Radiotherapy (SBRT)

    International Nuclear Information System (INIS)

    Price, A; Chang, S; Matney, J; Wang, A; Lian, J; Chao, E

    2016-01-01

    Purpose: Tomotherapy has unique challenges in handling intrafractional motion compared to conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data and investigated real time jaw/MLC compensation approaches to minimize the motion-induced dose discrepancy in Tomotherapy SBRT treatment. Methods: Intrafractional motion data recorded in two CyberKnife lung treatment cases through fiducial tracking and two LINAC prostate cases through Calypso tracking were used in this study. For each treatment site, one representative case has an average motion (6mm) and one has a large motion (10mm for lung and 15mm for prostate). The cases were re-planned on Tomotherapy for SBRT. Each case was planned with 3 different jaw settings: 1cm static, 2.5cm dynamic, and 5cm dynamic. 4D dose accumulation software was developed to compute dose with the recorded motions and theoretically compensate motions by modifying original jaw and MLC to track the trajectory of the tumor. Results: PTV coverage in Tomotherapy SBRT for patients with intrafractional motion depends on motion type, amplitude and plan settings. For the prostate patient with large motion, PTV coverage changed from 97.2% (motion-free) to 47.1% (target motion-included), 96.6% to 58.5% and 96.3% to 97.8% for the 1cm static jaw, 2.5cm dynamic jaw and 5cm dynamic jaw setting, respectively. For the lung patient with large motion, PTV coverage discrepancies showed a similar trend of change. When the jaw and MLC compensation program was engaged, the motion compromised PTV coverage was recovered back to >95% for all cases and plans. All organs at risk (OAR) were spared with < 5% increase from original motion-free plans. Conclusion: Tomotherapy SBRT is less motion-impacted when 5cm dynamic jaw is used. Once the motion pattern is known, the jaw and MLC compensation program can largely minimize the compromised target coverage and OAR sparing.

  4. Evaluation of the room shielding thickness of Hi-Art tomotherapy system

    International Nuclear Information System (INIS)

    Liu Haikuan; Wu Jinhai; Gu Naigu; Gao Yiming; Wang Li; Huang Weiqin; Wang Fengxian

    2010-01-01

    In this paper, we calculate and evaluate the room shielding thickness of a Hi-Art tomotherapy system, which is a new type of radiotherapy facility. Due to the self-shielding of the accelerator,only scattered beam and beam leakage were considered in calculating the room shielding thickness. The radiation field of the tomotherapy system was used as the basic data to calculate the shielding thickness of every 15 degree solid angle. The maximum shielding thickness required of each shielding wall was at the position with the angle of 15 degree, and the calculated shielding thickness were 1023, 975, 917, 1460, 1147 and 1189 mm for the east wall,south wall,west wall, north wall, the roof and the floor,respectively. According to the calculation results, all shielding walls, ceiling and floor could meet the requirement of the radiation protection, but the north wall thickness of 1200 mm was a little thinner. (authors)

  5. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    International Nuclear Information System (INIS)

    Wiezorek, Tilo; Schubert, Kai; Wagner, Daniela; Wendt, Thomas G; Brachwitz, Tim; Georg, Dietmar; Blank, Eyck; Fotina, Irina; Habl, Gregor; Kretschmer, Matthias; Lutters, Gerd; Salz, Henning

    2011-01-01

    Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx) using the following treatment planning systems (TPS) for rotational IMRT: Monaco (ELEKTA VMAT solution), Eclipse (Varian RapidArc solution) and HiArt for the helical tomotherapy (Tomotherapy). Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V 5Gy ). Additionally, the cumulative monitor units (MUs) and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V 5Gy values were lowest for the sliding window IMRT technique (3499 ccm) and largest for RapidArc (5480 ccm). The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. All IMRT delivery technologies with their associated TPS

  6. TomoTherapy MLC verification using exit detector data

    International Nuclear Information System (INIS)

    Chen Quan; Westerly, David; Fang Zhenyu; Sheng, Ke; Chen Yu

    2012-01-01

    Purpose: Treatment delivery verification (DV) is important in the field of intensity modulated radiation therapy (IMRT). While IMRT and image guided radiation therapy (IGRT), allow us to create more conformal plans and enables the use of tighter margins, an erroneously executed plan can have detrimental effects on the treatment outcome. The purpose of this study is to develop a DV technique to verify TomoTherapy's multileaf collimator (MLC) using the onboard mega-voltage CT detectors. Methods: The proposed DV method uses temporal changes in the MVCT detector signal to predict actual leaf open times delivered on the treatment machine. Penumbra and scattered radiation effects may produce confounding results when determining leaf open times from the raw detector data. To reduce the impact of the effects, an iterative, Richardson-Lucy (R-L) deconvolution algorithm is applied. Optical sensors installed on each MLC leaf are used to verify the accuracy of the DV technique. The robustness of the DV technique is examined by introducing different attenuation materials in the beam. Additionally, the DV technique has been used to investigate several clinical plans which failed to pass delivery quality assurance (DQA) and was successful in identifying MLC timing discrepancies as the root cause. Results: The leaf open time extracted from the exit detector showed good agreement with the optical sensors under a variety of conditions. Detector-measured leaf open times agreed with optical sensor data to within 0.2 ms, and 99% of the results agreed within 8.5 ms. These results changed little when attenuation was added in the beam. For the clinical plans failing DQA, the dose calculated from reconstructed leaf open times played an instrumental role in discovering the root-cause of the problem. Throughout the retrospective study, it is found that the reconstructed dose always agrees with measured doses to within 1%. Conclusions: The exit detectors in the TomoTherapy treatment systems

  7. Helicity content and tokamak applications of helicity

    International Nuclear Information System (INIS)

    Boozer, A.H.

    1986-05-01

    Magnetic helicity is approximately conserved by the turbulence associated with resistive instabilities of plasmas. To generalize the application of the concept of helicity, the helicity content of an arbitrary bounded region of space will be defined. The definition has the virtues that both the helicity content and its time derivative have simple expressions in terms of the poloidal and toroidal magnetic fluxes, the average toroidal loop voltage and the electric potential on the bounding surface, and the volume integral of E-B. The application of the helicity concept to tokamak plasmas is illustrated by a discussion of so-called MHD current drive, an example of a stable tokamak q profile with q less than one in the center, and a discussion of the possibility of a natural steady-state tokamak due to the bootstrap current coupling to tearing instabilities

  8. Radiation survey of first Hi-Art II Tomotherapy vault design in India

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A.; Jamema, S.V.; Pai, Rajeshree; Sharma, P.K. Dash; Deshpande, Deepak D.

    2009-01-01

    A vault as per government-regulation compliance with adequate shielding needs was designed and constructed for Hi-Art II Tomotherapy machine being the first in India. Radiation measurements around this Tomotherapy treatment vault were carried out to check the shielding adequacy of the source housing and the vault. It was mandatory to get this un-conventional machine 'Type Approved' by Atomic Energy Regulatory Board (AERB) in India. The aim of this paper was to report on the radiation levels measured during the radiation survey carried out for this machine. The radiation levels in and around the vault were measured for stationary as well as rotational treatment procedures with the largest open field size (5 cm x 40 cm) at the isocenter with and without scattering medium. The survey was performed at three locations near each wall surrounding the vault as well. The leakage radiation from the source housing was measured both in the patient plane outside the treatment field and one meter distance from the source outside the patient plane. The radiation levels both for stationary as well as rotational procedures were within 1 mR/h. No significance difference was observed in the radiation levels measured for rotational procedures with and without scattering medium. The leakage radiation in the patient plane was found to be 0.04% (Tolerance 0.2%), while the head leakage was 0.007% (Tolerance 0.5%) of the dose rate at the isocenter. The treatment delivery with Tomotherapy does play safe radiation levels around the installation layout and also passes the leakage criteria as well.

  9. The use of computed tomographic three-dimensional reconstructions to develop instructional models for equine pelvic ultrasonography.

    Science.gov (United States)

    Whitcomb, Mary Beth; Doval, John; Peters, Jason

    2011-01-01

    Ultrasonography has gained increased utility to diagnose pelvic fractures in horses; however, internal pelvic contours can be difficult to appreciate from external palpable landmarks. We developed three-dimensional (3D) simulations of the pelvic ultrasonographic examination to assist with translation of pelvic contours into two-dimensional (2D) images. Contiguous 1mm transverse computed tomography (CT) images were acquired through an equine femur and hemipelvis using a single slice helical scanner. 3D surface models were created using a DICOM reader and imported into a 3D modeling and animation program. The bone models were combined with a purchased 3D horse model and the skin made translucent to visualize pelvic surface contours. 3D models of ultrasound transducers were made from reference photos, and a thin sector shape was created to depict the ultrasound beam. Ultrasonographic examinations were simulated by moving transducers on the skin surface and rectally to produce images of pelvic structures. Camera angles were manipulated to best illustrate the transducer-beam-bone interface. Fractures were created in multiple configurations. Animations were exported as QuickTime movie files for use in presentations coupled with corresponding ultrasound videoclips. 3D models provide a link between ultrasonographic technique and image generation by depicting the interaction of the transducer, ultrasound beam, and structure of interest. The horse model was important to facilitate understanding of the location of pelvic structures relative to the skin surface. While CT acquisition time was brief, manipulation within the 3D software program was time intensive. Results were worthwhile from an instructional standpoint based on user feedback. © 2011 Veterinary Radiology & Ultrasound.

  10. Godbillon Vey Helicity and Magnetic Helicity in Magnetohydrodynamics

    Science.gov (United States)

    Webb, G. M.; Hu, Q.; Anco, S.; Zank, G. P.

    2017-12-01

    The Godbillon-Vey invariant arises in homology theory, and algebraic topology, where conditions for a layered family of 2D surfaces forms a 3D manifold were elucidated. The magnetic Godbillon-Vey helicity invariant in magnetohydrodynamics (MHD) is a helicity invariant that occurs for flows, in which the magnetic helicity density hm= A\\cdotB=0 where A is the magnetic vector potential and B is the magnetic induction. Our purpose is to elucidate the evolution of the magnetic Godbillon-Vey field η =A×B/|A|2 and the Godbillon-Vey helicity hgv}= η \\cdot∇ × η in general MHD flows in which the magnetic helicity hm≠q 0. It is shown that hm acts as a source term in the Godbillon-Vey helicity transport equation, in which hm is coupled to hgv via the shear tensor of the background flow. The transport equation for hgv depends on the electric field potential ψ , which is related to the gauge for A, which takes its simplest form for the advected A gauge in which ψ =A\\cdot u where u is the fluid velocity.

  11. Monte Carlo-based simulation of dynamic jaws tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sterpin, E.; Chen, Y.; Chen, Q.; Lu, W.; Mackie, T. R.; Vynckier, S. [Department of Molecular Imaging, Radiotherapy and Oncology, Universite Catholique de Louvain, 54 Avenue Hippocrate, 1200 Brussels, Belgium and Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); TomoTherapy Inc., 1240 Deming Way, Madison, Wisconsin 53717 (United States); 21 Century Oncology., 1240 D' onofrio, Madison, Wisconsin 53719 (United States); TomoTherapy Inc., 1240 Deming Way, Madison, Wisconsin 53717 and Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Department of Radiotherapy and Oncology, Universite Catholique de Louvain, St-Luc University Hospital, 10 Avenue Hippocrate, 1200 Brussels (Belgium)

    2011-09-15

    Purpose: Original TomoTherapy systems may involve a trade-off between conformity and treatment speed, the user being limited to three slice widths (1.0, 2.5, and 5.0 cm). This could be overcome by allowing the jaws to define arbitrary fields, including very small slice widths (<1 cm), which are challenging for a beam model. The aim of this work was to incorporate the dynamic jaws feature into a Monte Carlo (MC) model called TomoPen, based on the MC code PENELOPE, previously validated for the original TomoTherapy system. Methods: To keep the general structure of TomoPen and its efficiency, the simulation strategy introduces several techniques: (1) weight modifiers to account for any jaw settings using only the 5 cm phase-space file; (2) a simplified MC based model called FastStatic to compute the modifiers faster than pure MC; (3) actual simulation of dynamic jaws. Weight modifiers computed with both FastStatic and pure MC were compared. Dynamic jaws simulations were compared with the convolution/superposition (C/S) of TomoTherapy in the ''cheese'' phantom for a plan with two targets longitudinally separated by a gap of 3 cm. Optimization was performed in two modes: asymmetric jaws-constant couch speed (''running start stop,'' RSS) and symmetric jaws-variable couch speed (''symmetric running start stop,'' SRSS). Measurements with EDR2 films were also performed for RSS for the formal validation of TomoPen with dynamic jaws. Results: Weight modifiers computed with FastStatic were equivalent to pure MC within statistical uncertainties (0.5% for three standard deviations). Excellent agreement was achieved between TomoPen and C/S for both asymmetric jaw opening/constant couch speed and symmetric jaw opening/variable couch speed, with deviations well within 2%/2 mm. For RSS procedure, agreement between C/S and measurements was within 2%/2 mm for 95% of the points and 3%/3 mm for 98% of the points, where dose is

  12. Monte Carlo-based simulation of dynamic jaws tomotherapy

    International Nuclear Information System (INIS)

    Sterpin, E.; Chen, Y.; Chen, Q.; Lu, W.; Mackie, T. R.; Vynckier, S.

    2011-01-01

    Purpose: Original TomoTherapy systems may involve a trade-off between conformity and treatment speed, the user being limited to three slice widths (1.0, 2.5, and 5.0 cm). This could be overcome by allowing the jaws to define arbitrary fields, including very small slice widths (<1 cm), which are challenging for a beam model. The aim of this work was to incorporate the dynamic jaws feature into a Monte Carlo (MC) model called TomoPen, based on the MC code PENELOPE, previously validated for the original TomoTherapy system. Methods: To keep the general structure of TomoPen and its efficiency, the simulation strategy introduces several techniques: (1) weight modifiers to account for any jaw settings using only the 5 cm phase-space file; (2) a simplified MC based model called FastStatic to compute the modifiers faster than pure MC; (3) actual simulation of dynamic jaws. Weight modifiers computed with both FastStatic and pure MC were compared. Dynamic jaws simulations were compared with the convolution/superposition (C/S) of TomoTherapy in the ''cheese'' phantom for a plan with two targets longitudinally separated by a gap of 3 cm. Optimization was performed in two modes: asymmetric jaws-constant couch speed (''running start stop,'' RSS) and symmetric jaws-variable couch speed (''symmetric running start stop,'' SRSS). Measurements with EDR2 films were also performed for RSS for the formal validation of TomoPen with dynamic jaws. Results: Weight modifiers computed with FastStatic were equivalent to pure MC within statistical uncertainties (0.5% for three standard deviations). Excellent agreement was achieved between TomoPen and C/S for both asymmetric jaw opening/constant couch speed and symmetric jaw opening/variable couch speed, with deviations well within 2%/2 mm. For RSS procedure, agreement between C/S and measurements was within 2%/2 mm for 95% of the points and 3%/3 mm for 98% of the points, where dose is greater than 30% of the prescription dose (gamma analysis

  13. Breast conserving treatment for breast cancer: dosimetric comparison of sequential versus simultaneous integrated photon boost.

    Science.gov (United States)

    Van Parijs, Hilde; Reynders, Truus; Heuninckx, Karina; Verellen, Dirk; Storme, Guy; De Ridder, Mark

    2014-01-01

    Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining normofractionation on the breast. For 10 patients 4 treatment plans were deployed, 1 with a sequential photon boost, and 3 with different SIB techniques: on a conventional linear accelerator, helical TomoTherapy, and static TomoDirect. Dosimetric comparison was performed. PTV-coverage was good in all techniques. Conformity was better with all SIB techniques compared to sequential boost (P = 0.0001). There was less dose spilling to the ipsilateral breast outside the PTVboost (P = 0.04). The dose to the organs at risk (OAR) was not influenced by SIB compared to sequential boost. Helical TomoTherapy showed a higher mean dose to the contralateral breast, but less than 5 Gy for each patient. SIB showed less dose spilling within the breast and equal dose to OAR compared to sequential boost. Both helical TomoTherapy and the conventional technique delivered acceptable dosimetry. SIB seems a safe alternative and can be implemented in clinical routine.

  14. MO-D-213-04: The Proximity to the Skin of PTV Affects PTV Coverage and Skin Dose for TomoTherapy

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, T; Higgins, P; Watanabe, Y [University of Minnesota, Minneapolis, MN (United States)

    2015-06-15

    Purpose: The proximity to the skin surface of the PTV for the patients with skin disease could be a concern in terms of the PTV coverage and actual surface dose (SD). IMRT optimization algorithms increase the beam intensity close to the skin in order to compensate for lack of scattering material, leading to enhanced SD but potential hot spots. This study aims to investigate the effect of PTV proximity to the skin on planning and measured SD Methods: All measurements were done for 6 MV X-ray beam of Helical TomoTherapy. An anthropomorphic phantom was scanned in a CT simulator in a routine manner with thermoplastic mask immobilization. PTVs were created with varying distances to the skin of 0 mm -(PTV1), 1 mm- (PTV2), 2 mm-(PTV3) and 3 mm-(PTV4). Also, a 5 mm bolus was used with PTV1 (PTV5). All planning constraints were kept the same in all studies (hard constraint: 95% of the prescription dose covered 95% of the PTV). Gafchromic film (EBT3) was placed under the mask on the phantom surface, and the resulting dose was estimated using RIT software. Results: Optimizing the dose using different PTVs lead to average planned target doses of 10.8, 10.3, 10.2, 10.3 and 10.0 Gy, with maximum doses 12.2, 11.2, 11.1, 11.1 and 10.0 Gy for PTV1, PTV2, PTV3, PTV4 and PTV5, respectively. EBT3 measurements indicated a significant decrease of SD with skin distance by 12.7% (PTV1), 21.9% (PTV2), 24.8% (PTV3) and 28.4% (PTV4) comparing to prescription dose. Placement of a 5 mm bolus on the phantom surface resulted in a SD close to prescribed (+0.5%). Conclusion: This work provides a clear demonstration of the relationship between the skin dose and the PTV to the skin distance. The results indicate the necessity of a bolus even for TomoTherapy when high skin dose is required.

  15. MO-D-213-04: The Proximity to the Skin of PTV Affects PTV Coverage and Skin Dose for TomoTherapy

    International Nuclear Information System (INIS)

    Reynolds, T; Higgins, P; Watanabe, Y

    2015-01-01

    Purpose: The proximity to the skin surface of the PTV for the patients with skin disease could be a concern in terms of the PTV coverage and actual surface dose (SD). IMRT optimization algorithms increase the beam intensity close to the skin in order to compensate for lack of scattering material, leading to enhanced SD but potential hot spots. This study aims to investigate the effect of PTV proximity to the skin on planning and measured SD Methods: All measurements were done for 6 MV X-ray beam of Helical TomoTherapy. An anthropomorphic phantom was scanned in a CT simulator in a routine manner with thermoplastic mask immobilization. PTVs were created with varying distances to the skin of 0 mm -(PTV1), 1 mm- (PTV2), 2 mm-(PTV3) and 3 mm-(PTV4). Also, a 5 mm bolus was used with PTV1 (PTV5). All planning constraints were kept the same in all studies (hard constraint: 95% of the prescription dose covered 95% of the PTV). Gafchromic film (EBT3) was placed under the mask on the phantom surface, and the resulting dose was estimated using RIT software. Results: Optimizing the dose using different PTVs lead to average planned target doses of 10.8, 10.3, 10.2, 10.3 and 10.0 Gy, with maximum doses 12.2, 11.2, 11.1, 11.1 and 10.0 Gy for PTV1, PTV2, PTV3, PTV4 and PTV5, respectively. EBT3 measurements indicated a significant decrease of SD with skin distance by 12.7% (PTV1), 21.9% (PTV2), 24.8% (PTV3) and 28.4% (PTV4) comparing to prescription dose. Placement of a 5 mm bolus on the phantom surface resulted in a SD close to prescribed (+0.5%). Conclusion: This work provides a clear demonstration of the relationship between the skin dose and the PTV to the skin distance. The results indicate the necessity of a bolus even for TomoTherapy when high skin dose is required

  16. Monte Carlo simulations of patient dose perturbations in rotational-type radiotherapy due to a transverse magnetic field: A tomotherapy investigation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Y. M.; Geurts, M.; Smilowitz, J. B.; Bednarz, B. P., E-mail: bbednarz2@wisc.edu [Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin, Madison, Wisconsin 53703 (United States); Sterpin, E. [Molecular Imaging, Radiotherapy and Oncology, Université catholique de Louvain, Brussels, Belgium 1348 (Belgium)

    2015-02-15

    Purpose: Several groups are exploring the integration of magnetic resonance (MR) image guidance with radiotherapy to reduce tumor position uncertainty during photon radiotherapy. The therapeutic gain from reducing tumor position uncertainty using intrafraction MR imaging during radiotherapy could be partially offset if the negative effects of magnetic field-induced dose perturbations are not appreciated or accounted for. The authors hypothesize that a more rotationally symmetric modality such as helical tomotherapy will permit a systematic mediation of these dose perturbations. This investigation offers a unique look at the dose perturbations due to homogeneous transverse magnetic field during the delivery of Tomotherapy{sup ®} Treatment System plans under varying degrees of rotational beamlet symmetry. Methods: The authors accurately reproduced treatment plan beamlet and patient configurations using the Monte Carlo code GEANT4. This code has a thoroughly benchmarked electromagnetic particle transport physics package well-suited for the radiotherapy energy regime. The three approved clinical treatment plans for this study were for a prostate, head and neck, and lung treatment. The dose heterogeneity index metric was used to quantify the effect of the dose perturbations to the target volumes. Results: The authors demonstrate the ability to reproduce the clinical dose–volume histograms (DVH) to within 4% dose agreement at each DVH point for the target volumes and most planning structures, and therefore, are able to confidently examine the effects of transverse magnetic fields on the plans. The authors investigated field strengths of 0.35, 0.7, 1, 1.5, and 3 T. Changes to the dose heterogeneity index of 0.1% were seen in the prostate and head and neck case, reflecting negligible dose perturbations to the target volumes, a change from 5.5% to 20.1% was observed with the lung case. Conclusions: This study demonstrated that the effect of external magnetic fields can

  17. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    Directory of Open Access Journals (Sweden)

    Lutters Gerd

    2011-02-01

    Full Text Available Abstract Background Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Methods Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx using the following treatment planning systems (TPS for rotational IMRT: Monaco (ELEKTA VMAT solution, Eclipse (Varian RapidArc solution and HiArt for the helical tomotherapy (Tomotherapy. Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V5Gy. Additionally, the cumulative monitor units (MUs and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Results Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V5Gy values were lowest for the sliding window IMRT technique (3499 ccm and largest for RapidArc (5480 ccm. The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. Conclusions All

  18. Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry

    International Nuclear Information System (INIS)

    Pavoni, J. F.; Pike, T. L.; Snow, J.; DeWerd, L.; Baffa, O.

    2012-01-01

    Purpose: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. Methods: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. Results: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%/3 mm and of 96.5% using 4%/4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. Conclusions: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements.

  19. Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pavoni, J. F.; Pike, T. L.; Snow, J.; DeWerd, L.; Baffa, O. [Departamento de Fisica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Av. Bandeirantes, 3900 - CEP 14040-901 - Bairro Monte Alegre - Ribeirao Preto, SP (Brazil); Medical Radiation Research Center, Department of Medical Physics, University of Wisconsin, 1111 Highland Avenue, B1002 WIMR, Madison, Wisconsin 53705-2275 (United States); Departamento de Fisica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Av. Bandeirantes, 3900 - CEP 14040-901 - Bairro Monte Alegre - Ribeirao Preto, SP (Brazil)

    2012-05-15

    Purpose: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. Methods: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. Results: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%/3 mm and of 96.5% using 4%/4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. Conclusions: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements.

  20. SU-F-J-62: Assessment of Dose Changes Due to Anterior-Posterior Patient Separation During Daily MVCT Scans

    Energy Technology Data Exchange (ETDEWEB)

    Leney, M [Wayne State University, Detroit, MI (United States); Nalichowski, A; Patel, S [Karmanos Cancer Institute, Detroit, MI (United States)

    2016-06-15

    Purpose: To determine the effects of patient separation on absolute dose and dose distribution in patients undergoing pelvic radiotherapy on TomoTherapy. Methods: An Alderson RANDO phantom with 4cm of bolus was imaged on a CT simulator and the resulting scans were contoured as a whole pelvic case. Using TomoTherapy Planning Station, the plan was designed to give 45 Gy to 95% of the treatment volume in 25 fractions. TomoTherapy MVCT scans were performed on the RANDO phantom with 2cm and 4cm of bolus removed to simulate visible changes in a patient’s anatomy. The MVCT images were rigidly registered with planning CT images on TomoTherapy Planned Adaptive. The original fluence was recalculated on the MVCT images and changes in dose distribution due to patient separation were quantified by the changes in DVHs for the target volume and the organs at risk. Results: Patient separation difference equivalent to 2cm and 4cm in anterior-posterior direction resulted in an increase of the PTV D50 and maximum PTV dose of 5.6%, 6.2% for 2cm and 7.7%, 10.4% for 4cm, respectively. For the 2cm change, D50 and maximum doses to organs at risk increased by 6.5%, 7.1% in the bladder, 4.9%, 4.8% in the rectum, and 5.3%, 6.6% in the bowel. For the 4cm change, D50 and maximum doses increased by 10.7%, 12.2% in the bladder, 5.9%, 6.1% in the rectum, and 7.7%, 10.1% in the bowel. Conclusion: This research indicates that, without any changes to the structures, patient separation in the anterior-posterior direction can affect the dose distribution for the PTV and organs at risk. These results can assist physicians in determining if obtaining a new CT simulation set and replanning is necessary for pelvic patients on TomoTherapy.

  1. Impact of the Lok-bar for High-precision Radiotherapy with Tomotherapy.

    Science.gov (United States)

    Hirata, Makoto; Monzen, Hajime; Tamura, Mikoto; Kubo, Kazuki; Matsumoto, Kenji; Hanaoka, Kohei; Okumura, Masahiko; Nishimura, Yasumasa

    2018-05-01

    Patient immobilization systems are used to establish a reproducible patient position relative to the couch. In this study, the impact of conventional lok-bars for CT-simulation (CIVCO-bar) and treatment (iBEAM-bar) were compared with a novel lok-bar (mHM-bar) in tomotherapy. Verification was obtained as follows: i. artifacts in CT images; ii. dose attenuation rate of lok-bar, compared to without lok-bar; and iii. dose differences between the calculated and measured absorbed doses. With the CIVCO-bar, there were obvious metal artifacts, while there were nearly no artifacts with the mHM-bar. The mean dose attenuation rates with the mHM-bar and iBEAM-bar were 1.31% and 2.28%, and the mean dose difference was 1.55% and 1.66% for mHM-bar and iBEAM-bar. Using the mHM-bar reduced artifacts on the CT image and improved dose attenuation are obtained. The lok-bar needs to be inserted as a structure set in treatment planning with tomotherapy. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  2. Pelvic floor muscle function in women with pelvic floor dysfunction

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Dehlendorff, Christian

    2014-01-01

    The objectives of this study were to investigate the level of pelvic floor muscle (PFM) function in women with pelvic floor dysfunction (PFD) referred by gynaecologists and urologists for in-hospital pelvic floor muscle training (PFMT), and to identity associated factors for a low level of PFM...

  3. Realization of fluence field modulated CT on a clinical TomoTherapy megavoltage CT system

    International Nuclear Information System (INIS)

    Szczykutowicz, Timothy P; Hermus, James; Geurts, Mark; Smilowitz, Jennifer

    2015-01-01

    The multi-leaf collimator (MLC) assembly present on TomoTherapy (Accuray, Madison WI) radiation therapy (RT) and mega voltage CT machines is well suited to perform fluence field modulated CT (FFMCT). In addition, there is a demand in the RT environment for FFMCT imaging techniques, specifically volume of interest (VOI) imaging.A clinical TomoTherapy machine was programmed to perform VOI. Four different size ROIs were placed at varying distances from isocenter. Projections intersecting the VOI received ‘full dose’ while those not intersecting the VOI received 30% of the dose (i.e. the incident fluence for non VOI projections was 30% of the incident fluence for projections intersecting the VOI). Additional scans without fluence field modulation were acquired at ‘full’ and 30% dose. The noise (pixel standard deviation) and mean CT number were measured inside the VOI region and compared between the three scans. Dose maps were generated using a dedicated TomoTherapy treatment planning dose calculator.The VOI-FFMCT technique produced an image noise 1.05, 1.00, 1.03, and 1.05 times higher than the ‘full dose’ scan for ROI sizes of 10 cm, 13 cm, 10 cm, and 6 cm respectively within the VOI region. The VOI-FFMCT technique required a total imaging dose equal to 0.61, 0.69, 0.60, and 0.50 times the ‘full dose’ acquisition dose for ROI sizes of 10 cm, 13 cm, 10 cm, and 6 cm respectively within the VOI region.Noise levels can be almost unchanged within clinically relevant VOIs sizes for RT applications while the integral imaging dose to the patient can be decreased, and/or the image quality in RT can be dramatically increased with no change in dose relative to non-FFMCT RT imaging. The ability to shift dose away from regions unimportant for clinical evaluation in order to improve image quality or reduce imaging dose has been demonstrated. This paper demonstrates that FFMCT can be performed using the MLC on a clinical TomoTherapy machine for the

  4. Pelvic Muscle Rehabilitation: A Standardized Protocol for Pelvic Floor Dysfunction

    Directory of Open Access Journals (Sweden)

    Rodrigo Pedraza

    2014-01-01

    Full Text Available Introduction. Pelvic floor dysfunction syndromes present with voiding, sexual, and anorectal disturbances, which may be associated with one another, resulting in complex presentation. Thus, an integrated diagnosis and management approach may be required. Pelvic muscle rehabilitation (PMR is a noninvasive modality involving cognitive reeducation, modification, and retraining of the pelvic floor and associated musculature. We describe our standardized PMR protocol for the management of pelvic floor dysfunction syndromes. Pelvic Muscle Rehabilitation Program. The diagnostic assessment includes electromyography and manometry analyzed in 4 phases: (1 initial baseline phase; (2 rapid contraction phase; (3 tonic contraction and endurance phase; and (4 late baseline phase. This evaluation is performed at the onset of every session. PMR management consists of 6 possible therapeutic modalities, employed depending on the diagnostic evaluation: (1 down-training; (2 accessory muscle isolation; (3 discrimination training; (4 muscle strengthening; (5 endurance training; and (6 electrical stimulation. Eight to ten sessions are performed at one-week intervals with integration of home exercises and lifestyle modifications. Conclusions. The PMR protocol offers a standardized approach to diagnose and manage pelvic floor dysfunction syndromes with potential advantages over traditional biofeedback, involving additional interventions and a continuous pelvic floor assessment with management modifications over the clinical course.

  5. COMPUTED TOMOGRAPHY DOSE INDEX MEASUREMENT FOR Hi-ART MEGAVOLTAGE HELICAL CT.

    Science.gov (United States)

    Liu, Minglu; Wang, Yunlai; Liao, Xiongfei

    2016-11-01

    On-line megavoltage computed tomography (MVCT) images are used to verify patient daily set-up in Hi-ART helical TomoTherapy unit. To evaluate the patient dose from MVCT scanning in image guidance, weighted computed tomography (CT) dose index (CTDI w ) was measured with PTW TM30009 CT pencil chamber in head and body phantoms for slice thicknesses of 2, 4 and 6 mm with different scan lengths. Dose length products (DLPs) were subsequently calculated. The CTDI w and DLP were compared with XVI kV CBCT and Brilliance simulator CT for routine clinical protocols. It was shown that CTDI and DLP had close relationship with the slice thickness and the scan length. The dose distribution in the transversal plane was very inhomogeneous due to the attenuation of the couch. Patient dose from MVCT was lower than XVI CBCT for the head scan, while larger for body scan. CTDI w , which is measured easily and reproducibly, can be used to assess the patient dose in MVCT. Regular measurement should be performed in QA & QC programmes. Appropriate slice thickness and scan range should be chosen to reduce the patient dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. The Role of Pelvic Floor Muscles in Male Sexual Dysfunction and Pelvic Pain.

    Science.gov (United States)

    Cohen, Deborah; Gonzalez, Joshua; Goldstein, Irwin

    2016-01-01

    Sexual function is essential to good health and well-being in men. The relationship between male sexual function, pelvic floor function, and pelvic pain is complex and only beginning to be appreciated. The objectives of the current review are to examine these complex relationships, and to demonstrate how pelvic floor physical therapy can potentially improve the treatment of various male sexual dysfunctions, including erectile dysfunction and dysfunction of ejaculation and orgasm. Contemporary data on pelvic floor anatomy and function as they relate to the treatment of various male sexual dysfunctions were reviewed. Examination of evidence supporting the association between the male pelvic floor and erectile dysfunction, ejaculatory/orgasmic dysfunction, and chronic prostatitis/chronic pelvic pain syndrome, respectively. Evidence suggests a close relationship between the pelvic floor and male sexual dysfunction and a potential therapeutic benefit from pelvic floor therapy for men who suffer from these conditions. Pelvic floor physical therapy is a necessary tool in a more comprehensive bio-neuromusculoskeletal-psychosocial approach to the treatment of male sexual dysfunction and pelvic pain. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  7. Conversion from mutual helicity to self-helicity observed with IRIS

    Science.gov (United States)

    Li, L. P.; Peter, H.; Chen, F.; Zhang, J.

    2014-10-01

    Context. In the upper atmosphere of the Sun observations show convincing evidence for crossing and twisted structures, which are interpreted as mutual helicity and self-helicity. Aims: We use observations with the new Interface Region Imaging Spectrograph (IRIS) to show the conversion of mutual helicity into self-helicity in coronal structures on the Sun. Methods: Using far UV spectra and slit-jaw images from IRIS and coronal images and magnetograms from SDO, we investigated the evolution of two crossing loops in an active region, in particular, the properties of the Si IV line profile in cool loops. Results: In the early stage two cool loops cross each other and accordingly have mutual helicity. The Doppler shifts in the loops indicate that they wind around each other. As a consequence, near the crossing point of the loops (interchange) reconnection sets in, which heats the plasma. This is consistent with the observed increase of the line width and of the appearance of the loops at higher temperatures. After this interaction, the two new loops run in parallel, and in one of them shows a clear spectral tilt of the Si IV line profile. This is indicative of a helical (twisting) motion, which is the same as to say that the loop has self-helicity. Conclusions: The high spatial and spectral resolution of IRIS allowed us to see the conversion of mutual helicity to self-helicity in the (interchange) reconnection of two loops. This is observational evidence for earlier theoretical speculations. Movie associated with Fig. 1 and Appendix A are available in electronic form at http://www.aanda.org

  8. Breast Conserving Treatment for Breast Cancer: Dosimetric Comparison of Sequential versus Simultaneous Integrated Photon Boost

    Directory of Open Access Journals (Sweden)

    Hilde Van Parijs

    2014-01-01

    Full Text Available Background. Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB compared to a sequential boost to hypofractionate the boost volume, while maintaining normofractionation on the breast. Methods. For 10 patients 4 treatment plans were deployed, 1 with a sequential photon boost, and 3 with different SIB techniques: on a conventional linear accelerator, helical TomoTherapy, and static TomoDirect. Dosimetric comparison was performed. Results. PTV-coverage was good in all techniques. Conformity was better with all SIB techniques compared to sequential boost (P = 0.0001. There was less dose spilling to the ipsilateral breast outside the PTVboost (P = 0.04. The dose to the organs at risk (OAR was not influenced by SIB compared to sequential boost. Helical TomoTherapy showed a higher mean dose to the contralateral breast, but less than 5 Gy for each patient. Conclusions. SIB showed less dose spilling within the breast and equal dose to OAR compared to sequential boost. Both helical TomoTherapy and the conventional technique delivered acceptable dosimetry. SIB seems a safe alternative and can be implemented in clinical routine.

  9. Quantifying Appropriate PTV Setup Margins: Analysis of Patient Setup Fidelity and Intrafraction Motion Using Post-Treatment Megavoltage Computed Tomography Scans

    International Nuclear Information System (INIS)

    Drabik, Donata M.; MacKenzie, Marc A.; Fallone, Gino B.

    2007-01-01

    Purpose: To present a technique that can be implemented in-house to evaluate the efficacy of immobilization and image-guided setup of patients with different treatment sites on helical tomotherapy. This technique uses an analysis of alignment shifts between kilovoltage computed tomography and post-treatment megavoltage computed tomography images. The determination of the shifts calculated by the helical tomotherapy software for a given site can then be used to define appropriate planning target volume internal margins. Methods and Materials: Twelve patients underwent post-treatment megavoltage computed tomography scans on a helical tomotherapy machine to assess patient setup fidelity and net intrafraction motion. Shifts were studied for the prostate, head and neck, and glioblastoma multiforme. Analysis of these data was performed using automatic and manual registration of the kilovoltage computed tomography and post-megavoltage computed tomography images. Results: The shifts were largest for the prostate, followed by the head and neck, with glioblastoma multiforme having the smallest shifts in general. It appears that it might be more appropriate to use asymmetric planning target volume margins. Each margin value reported is equal to two standard deviations of the average shift in the given direction. Conclusion: This method could be applied using individual patient post-image scanning and combined with adaptive planning to reduce or increase the margins as appropriate

  10. Helicity, Reconnection, and Dynamo Effects

    International Nuclear Information System (INIS)

    Ji, Hantao

    1998-01-01

    The inter-relationships between magnetic helicity, magnetic reconnection, and dynamo effects are discussed. In laboratory experiments, where two plasmas are driven to merge, the helicity content of each plasma strongly affects the reconnection rate, as well as the shape of the diffusion region. Conversely, magnetic reconnection events also strongly affect the global helicity, resulting in efficient helicity cancellation (but not dissipation) during counter-helicity reconnection and a finite helicity increase or decrease (but less efficiently than dissipation of magnetic energy) during co-helicity reconnection. Close relationships also exist between magnetic helicity and dynamo effects. The turbulent electromotive force along the mean magnetic field (alpha-effect), due to either electrostatic turbulence or the electron diamagnetic effect, transports mean-field helicity across space without dissipation. This has been supported by direct measurements of helicity flux in a laboratory plasma. When the dynamo effect is driven by electromagnetic turbulence, helicity in the turbulent field is converted to mean-field helicity. In all cases, however, dynamo processes conserve total helicity except for a small battery effect, consistent with the observation that the helicity is approximately conserved during magnetic relaxation

  11. Contribution of pelvic floor muscles to stiffness of the pelvic ring

    NARCIS (Netherlands)

    Pool-Goudzwaard, A.L.; Hoek van Dijke, G; van Gurp, M; Mulder, P; Snijders, C.J.; Stoeckart, R.

    2004-01-01

    STUDY DESIGN: A biomechanical study in embalmed specimens, on the relation between applied tension in the pelvic floor muscles, stiffness of the pelvic ring and generation of movement in the sacroiliac joints. OBJECTIVE: To gain insight into the effect of tension in the pelvic floor muscles on

  12. Dosimetric evaluation of tomography and four-box field conformal radiotherapy in locally advanced rectal cancer

    International Nuclear Information System (INIS)

    Yu, Mina; Lee, Hyo Chun; Chung, Mi Joo; Kim, Sung Hwan; Lee, Jong Hoon; Jang, Hong Seok; Jeon, Dong Min; Cheon, Geum Seong

    2013-01-01

    To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvis using Tomotherapy, between July 2010 and December 2010, were selected. Using their simulation computed tomography scans, Tomotherapy and four-box field CRT plans with the same dose schedule were evaluated, and dosimetric parameters of the two plans were compared. For the comparison of target coverage, we analyzed the mean dose, Vn Gy, Dmin, Dmax, radical dose homogeneity index (rDHI), and radiation conformity index (RCI). For the comparison of organs at risk (OAR), we analyzed the mean dose. Tomotherapy showed a significantly higher mean target dose than four-box field CRT (p 0.001). But, V26.25 Gy and V27.5 Gywere not significantly different between the two modalities. Tomotherapy showed higher Dmax and lower Dmin. The Tomotherapy plan had a lower rDHI than four-box field CRT (p = 0.000). Tomotherapy showed better RCI than four-box field CRT (p = 0.007). For OAR, the mean irradiated dose was significantly lower in Tomotherapy than four-box field CRT. In locally advanced rectal cancer, Tomotherapy delivers a higher conformal radiation dose to the target and reduces the irradiated dose to OAR than four-box field CRT.

  13. Dosimetric evaluation of tomography and four-box field conformal radiotherapy in locally advanced rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Mina; Lee, Hyo Chun; Chung, Mi Joo; Kim, Sung Hwan; Lee, Jong Hoon [Dept. of Radiation Oncology, St. Vincent' s Hospital, The Catholic University of Korea College of Medicine, Suwon (Korea, Republic of); Jang, Hong Seok; Jeon, Dong Min; Cheon, Geum Seong [Dept. of Radiation Oncology, Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2013-12-15

    To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvis using Tomotherapy, between July 2010 and December 2010, were selected. Using their simulation computed tomography scans, Tomotherapy and four-box field CRT plans with the same dose schedule were evaluated, and dosimetric parameters of the two plans were compared. For the comparison of target coverage, we analyzed the mean dose, Vn Gy, Dmin, Dmax, radical dose homogeneity index (rDHI), and radiation conformity index (RCI). For the comparison of organs at risk (OAR), we analyzed the mean dose. Tomotherapy showed a significantly higher mean target dose than four-box field CRT (p 0.001). But, V26.25 Gy and V27.5 Gywere not significantly different between the two modalities. Tomotherapy showed higher Dmax and lower Dmin. The Tomotherapy plan had a lower rDHI than four-box field CRT (p = 0.000). Tomotherapy showed better RCI than four-box field CRT (p = 0.007). For OAR, the mean irradiated dose was significantly lower in Tomotherapy than four-box field CRT. In locally advanced rectal cancer, Tomotherapy delivers a higher conformal radiation dose to the target and reduces the irradiated dose to OAR than four-box field CRT.

  14. Intra-pelvic pressure changes after pelvic fracture: A cadaveric study quantifying the effect of a pelvic binder and limb bandaging over a bolster.

    Science.gov (United States)

    Morris, Rhys; Loftus, Andrew; Friedmann, Yasmin; Parker, Paul; Pallister, Ian

    2017-04-01

    Unstable pelvic fractures can be life-threatening due to catastrophic haemorrhage. Non-invasive methods of reducing and stabilising these injuries include pelvic binder application and also lower limb bandaging over a knee-flexion bolster. Both of these methods help close the pelvic ring and should tamponade bleeding. This study aimed to quantify the intra-pelvic pressure changes that occurred with 3 different manoeuvres: lower limb bandaging over a bolster; a Trauma Pelvic Orthotic Device (T-POD) pelvic binder, and a combination of both. Following a pilot study with 2 soft embalmed cadavers, a formal study with 6 unembalmed cadavers was performed. For each specimen an unstable pelvic injury was created (OA/OTA 61-C1) by dividing the pelvic ring anteriorly and posteriorly. A 3-4cm manometric water-filled balloon was placed in the retropubic space and connected to a 50ml syringe and water manometer via a 3-way tap. A baseline pressure of 8cmH 2 O (equating to the average central venous pressure) was used for each cadaver. Steady intra-pelvic pressures (more reliably reflecting the pressures achieved following an intervention) were used in the subsequent statistical analysis, using R statistical language and Rstudio. Paired t-test or Wilcoxon's rank sum test were used (depending on the normality of the dataset) to determine the impact of each intervention on the intra-pelvic pressure. The mean steady intra-pelvic pressures were significantly greater than the baseline pressure for each intervention. The binder and limb bandaging over a bolster alone increased the mean steady pelvic pressures significantly to 24 (SE=5) (plower limb bandaging over a bolster and pelvic binder application significantly increased intra-pelvic pressure above the baseline pressure. This was further increased through combining these interventions, which could be useful clinically to augment haemorrhage control in these fractures. Lower-limb bandaging over a bolster, and pelvic binder

  15. Therapeutic benefits in grid irradiation on Tomotherapy for bulky, radiation-resistant tumors.

    Science.gov (United States)

    Narayanasamy, Ganesh; Zhang, Xin; Meigooni, Ali; Paudel, Nava; Morrill, Steven; Maraboyina, Sanjay; Peacock, Loverd; Penagaricano, Jose

    2017-08-01

    Spatially fractionated radiation therapy (SFRT or grid therapy) has proven to be effective in management of bulky tumors. The aim of this project is to study the therapeutic ratio (TR) of helical Tomotherapy (HT)-based grid therapy using linear-quadratic cell survival model. HT-based grid (or HT-GRID) plan was generated using a patient-specific virtual grid pattern of high-dose cylindrical regions using MLCs. TR was defined as the ratio of normal tissue surviving fraction (SF) under HT-GRID irradiation to an open debulking field of an equivalent dose that result in the same tumor cell SF. TR was estimated from DVH data on ten HT-GRID patient plans with deep seated, bulky tumor. Dependence of the TR values on radiosensitivity of the tumor cells and prescription dose was analyzed. The mean ± standard deviation (SD) of TR was 4.0 ± 0.7 (range: 3.1-5.5) for the 10 patients with single fraction maximum dose of 20 Gy to GTV assuming a tumor cell SF at 2 Gy (SF2 t ) value of 0·5. In addition, the mean ± SD of TR values for SF2 t values of 0.3 and 0.7 were found to be 1 ± 0.1 and 18.0 ± 5.1, respectively. Reducing the prescription dose to 15 and 10 Gy lowered the respective TR values to 2.0 ± 0.2 and 1.2 ± 0.04 for a SF2 t value of 0.5. HT-GRID therapy demonstrates a significant therapeutic advantage over uniform dose from an open field irradiation for the same tumor cell kill. TR increases with the radioresistance of the tumor cells and with prescription dose.

  16. Helical type vacuum container

    International Nuclear Information System (INIS)

    Owada, Kimio.

    1989-01-01

    Helical type vacuum containers in the prior art lack in considerations for thermal expansion stresses to helical coils, and there is a possibility of coil ruptures. The object of the present invention is to avoid the rupture of helical coils wound around the outer surface of a vacuum container against heat expansion if any. That is, bellows or heat expansion absorbing means are disposed to a cross section of a helical type vacuum container. With such a constitution, thermal expansion of helical coils per se due to temperature elevation of the coils during electric supply can be absorbed by expansion of the bellows or absorption of the heat expansion absorbing means. Further, this can be attained by arranging shear pins in the direction perpendicular to the bellows axis so that the bellows are not distorted when the helical coils are wound around the helical type vacuum container. (I.S.)

  17. Verification of skin dose according to the location of tumor in Tomotherapy

    International Nuclear Information System (INIS)

    Yoon, Bo Reum; Park, Su Yeon; Park, Byoung Suk; KIm, Jong Sik; Song, Ki Won

    2014-01-01

    To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5 mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5 mm and 10 mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3 mm and 5 mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5 mm and 3 mm respectively. If placed 5 mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10 mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5 mm and 3 mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10 mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2-17.1% whereas if the tumor is 5 mm away from the ceiling part, the figure decreased to 2.8-9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment

  18. Effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction

    Directory of Open Access Journals (Sweden)

    Shi-Qiong Li

    2017-04-01

    Full Text Available Objective: To explore the effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction and on the sexual life quality. Methods: A total of 286 puerpera with pelvic floor dysfunction who were admitted in our hospital from May, 2014 to May, 2015 42 d after delivery were included in the study, and randomized into the treatment group and the control group with 143 cases in each group. After guidance, the puerpera in the control group were given pelvic floor muscle training by themselves at home. On this basis, the puerpera in the treatment group were treated by the pelvic floor rehabilitation apparatus. The puerpera in the two groups were treated for 4 weeks. The pelvic floor function before treatment, 6 months and 1 year after delivery was detected. The color Doppler ultrasound apparatus was used to detect BSD, PUVA, UVJ-M, and BND 3 months after delivery. Results: BND, PUVA-R, PUVA-S, and UVJ-M 3 months after delivery in the treatment groups were significantly lower than those in the control group, while BSD-S was significantly higher than that in the control group. The improvement of type I and II muscle fiber fatigue (%, POP-Q degree, AP indication point (cm, and vaginal dynamic pressure (cmH2O was significantly superior to that in the control group. The comparison of pelvic floor muscle strength classification before treatment between the two groups was not statistically significant. After treatment, the pelvic floor muscle in the two groups was significantly strengthened, and the proportion of V grade patients was significantly increased when compared with before treatment. Conclusions: The postpartum early pelvic floor rehabilitation technique can effectively enhance the pelvic floor function, and prevent the postpartum pelvic floor dysfunction, with an accurate efficacy; therefore, it deserves to be widely recommended in the clinic.

  19. Hypofractionated radiotherapy for primary or secondary oligometastatic lung cancer using Tomotherapy

    International Nuclear Information System (INIS)

    Chang, Heng-Jui; Ko, Hui-Ling; Lee, Cheng-Yen; Wu, Ren-Hong; Yeh, Yu-Wung; Jiang, Jiunn-Song; Kao, Shang-Jyh; Chi, Kwan-Hwa

    2012-01-01

    To retrospectively review the outcome of patients with primary or secondary oligometastatic lung cancer, treated with hypofractionated Tomotherapy. Between April 2007 and June 2011, a total of 33 patients with oligometastatic intrapulmonary lesions underwent hypofractionated radiotherapy by Tomotherapy along with appropriate systemic therapy. There were 24 primary, and 9 secondary lung cancer cases. The radiation doses ranged from 4.5 to 7.0 Gy per fraction, multiplied by 8–16 fractions. The median dose per fraction was 4.5 Gy (range, 4.5-7.0 Gy), and the median total dose was 49.5 Gy (range, 45–72 Gy). The median estimated biological effective dose at 10 Gy (BED 10 ) was 71.8 Gy (range, 65.3–119.0 Gy), and that at 3 Gy (BED 3 ) was 123.8 Gy (range, 112.5–233.3 Gy). The mean lung dose (MLD) was constrained mainly under 1200 cGy. The median gross tumor volume (GTV) was 27.9 cm 3 (range: 2.5–178.1 cm 3 ). The median follow-up period was 25.8 months (range, 3.0–60.7 months). The median overall survival (OS) time was 32.1 months for the 24 primary lung cancer patients, and >40 months for the 9 metastatic lung patients. The median survival time of the patients with extra-pulmonary disease (EPD) was 11.2 months versus >50 months (not reached) in the patients without EPD (p < 0.001). Those patients with smaller GTV (≦27.9 cm 3 ) had a better survival than those with larger GTV (>27.9 cm 3 ): >40 months versus 12.85 months (p = 0.047). The patients with ≦2 lesions had a median survival >40 months, whereas those with ≧3 lesions had 26 months (p = 0.065). The 2-year local control (LC) rate was 94.7%. Only 2 patients (6.1%) developed ≧grade 3 radiation pneumonitis. Using Tomotherapy in hypofractionation may be effective for selected primary or secondary lung oligometastatic diseases, without causing significant toxicities. Pulmonary oligometastasis patients without EPD had better survival outcomes than those with EPD. Moreover, GTV is more significant than

  20. Hypofractionated radiotherapy for primary or secondary oligometastatic lung cancer using Tomotherapy

    Science.gov (United States)

    2012-01-01

    Background To retrospectively review the outcome of patients with primary or secondary oligometastatic lung cancer, treated with hypofractionated Tomotherapy. Methods Between April 2007 and June 2011, a total of 33 patients with oligometastatic intrapulmonary lesions underwent hypofractionated radiotherapy by Tomotherapy along with appropriate systemic therapy. There were 24 primary, and 9 secondary lung cancer cases. The radiation doses ranged from 4.5 to 7.0 Gy per fraction, multiplied by 8–16 fractions. The median dose per fraction was 4.5 Gy (range, 4.5-7.0 Gy), and the median total dose was 49.5 Gy (range, 45–72 Gy). The median estimated biological effective dose at 10 Gy (BED10) was 71.8 Gy (range, 65.3–119.0 Gy), and that at 3 Gy (BED3) was 123.8 Gy (range, 112.5–233.3 Gy). The mean lung dose (MLD) was constrained mainly under 1200 cGy. The median gross tumor volume (GTV) was 27.9 cm3 (range: 2.5–178.1 cm3). Results The median follow-up period was 25.8 months (range, 3.0–60.7 months). The median overall survival (OS) time was 32.1 months for the 24 primary lung cancer patients, and >40 months for the 9 metastatic lung patients. The median survival time of the patients with extra-pulmonary disease (EPD) was 11.2 months versus >50 months (not reached) in the patients without EPD (p 27.9 cm3): >40 months versus 12.85 months (p = 0.047). The patients with ≦2 lesions had a median survival >40 months, whereas those with ≧3 lesions had 26 months (p = 0.065). The 2-year local control (LC) rate was 94.7%. Only 2 patients (6.1%) developed ≧grade 3 radiation pneumonitis. Conclusion Using Tomotherapy in hypofractionation may be effective for selected primary or secondary lung oligometastatic diseases, without causing significant toxicities. Pulmonary oligometastasis patients without EPD had better survival outcomes than those with EPD. Moreover, GTV is more significant than lesion number in

  1. Chronic pelvic pain.

    Science.gov (United States)

    Stein, Sharon L

    2013-12-01

    Chronic pelvic pain is pain lasting longer than 6 months and is estimated to occur in 15% of women. Causes of pelvic pain include disorders of gynecologic, urologic, gastroenterologic, and musculoskeletal systems. The multidisciplinary nature of chronic pelvic pain may complicate diagnosis and treatment. Treatments vary by cause but may include medicinal, neuroablative, and surgical treatments. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Pelvic Actinomycosis

    Directory of Open Access Journals (Sweden)

    Alejandra García-García

    2017-01-01

    Full Text Available Introduction. Actinomycosis is a chronic bacterial infection caused by Actinomyces, Gram-positive anaerobic bacteria. Its symptomatology imitates some malignant pelvic tumours, tuberculosis, or nocardiosis, causing abscesses and fistulas. Actinomycoses are opportunistic infections and require normal mucous barriers to be altered. No epidemiological studies have been conducted to determine prevalence or incidence of such infections. Objective. To analyse the clinical cases of pelvic actinomycosis reported worldwide, to update the information about the disease. Methods. A systematic review of worldwide pelvic actinomycosis cases between 1980 and 2014 was performed, utilising the PubMed, Scopus, and Google Scholar databases. The following information was analysed: year, country, type of study, number of cases, use of intrauterine device (IUD, final and initial diagnosis, and method of diagnosis. Results. 63 articles met the search criteria, of which 55 reported clinical cases and 8 reported cross-sectional studies. Conclusions. Pelvic actinomycosis is confusing to diagnose and should be considered in the differential diagnosis of pelvic chronic inflammatory lesions. It is commonly diagnosed through a histological report, obtained after a surgery subsequent to an erroneous initial diagnosis. A bacterial culture in anaerobic medium could be useful for the diagnosis but requires a controlled technique and should be performed using specialised equipment.

  3. Validation of the Pelvic Floor Distress Inventory-20 and the Pelvic Floor Impact Questionnaire-7 in Danish women with pelvic organ prolapse

    DEFF Research Database (Denmark)

    Due, Ulla; Brostrøm, Søren; Lose, Gunnar

    2013-01-01

    To translate the Pelvic Floor Distress Inventory-20 (PFDI-20) and the Pelvic Floor Impact Questionnaire-7 (PFIQ-7) and to evaluate their psychometric properties in Danish women with symptomatic pelvic organ prolapse....

  4. Pelvic and acetabular fractures

    International Nuclear Information System (INIS)

    Mears, D.C.; Rubash, H.E.

    1986-01-01

    This treatise focuses primarily on the clinical aspects of diagnosis and treatments of pelvic and acetabular fractures. However, considerable attention is also paid to the radiographic diagnosis of trauma and postoperative effects. The book begins with a succinct review of pelvic and acetabular anatomy and pelvic biomechanics. It continues with a radiographic classification of pelvic injury, which will represent the major source of the book's interest for radiologists. The remainder of the book is concerned with clinical management of pelvic and acetabular trauma, including preoperative planning, surgical approaches, techniques of reduction, internal fixation, eternal fixation, post-operative care, and late problems. Even throughout this later portion of the book there are extensive illustrations, including plain radiographs, computed tomographic (CT) scans, reconstructed three-dimensional CT scans, and schematic diagrams of diverse pelvic and acetabular fractures and the elementary surgical techniques for their repair

  5. Actual Dose Variation of Parotid Glands and Spinal Cord for Nasopharyngeal Cancer Patients During Radiotherapy

    International Nuclear Information System (INIS)

    Han Chunhui; Chen Yijen; Liu An; Schultheiss, Timothy E.; Wong, Jeffrey Y.C.

    2008-01-01

    Purpose: For intensity-modulated radiotherapy of nasopharyngeal cancer, accurate dose delivery is crucial to the success of treatment. This study aimed to evaluate the significance of daily image-guided patient setup corrections and to quantify the parotid gland volume and dose variations for nasopharyngeal cancer patients using helical tomotherapy megavoltage computed tomography (CT). Methods and Materials: Five nasopharyngeal cancer patients who underwent helical tomotherapy were selected retrospectively. Each patient had received 70 Gy in 35 fractions. Daily megavoltage CT scans were registered with the planning CT images to correct the patient setup errors. Contours of the spinal cord and parotid glands were drawn on the megavoltage CT images at fixed treatment intervals. The actual doses delivered to the critical structures were calculated using the helical tomotherapy Planned Adaptive application. Results: The maximal dose to the spinal cord showed a significant increase and greater variation without daily setup corrections. The significant decrease in the parotid gland volume led to a greater median dose in the later phase of treatment. The average parotid gland volume had decreased from 20.5 to 13.2 cm 3 by the end of treatment. On average, the median dose to the parotid glands was 83 cGy and 145 cGy for the first and the last treatment fractions, respectively. Conclusions: Daily image-guided setup corrections can eliminate significant dose variations to critical structures. Constant monitoring of patient anatomic changes and selective replanning should be used during radiotherapy to avoid critical structure complications

  6. Integral dose delivered to normal brain with conventional intensity-modulated radiotherapy (IMRT) and helical tomotherapy IMRT during partial brain radiotherapy for high-grade gliomas with and without selective sparing of the hippocampus, limbic circuit and neural stem cell compartment

    International Nuclear Information System (INIS)

    Marsh, James C.; Ziel, Ellis G; Diaz, Aidnag Z; Turian, Julius V; Wendt, Julie A.; Gobole, Rohit

    2013-01-01

    We compared integral dose with uninvolved brain (ID brain ) during partial brain radiotherapy (PBRT) for high-grade glioma patients using helical tomotherapy (HT) and seven field traditional inverse-planned intensity-modulated radiotherapy (IMRT) with and without selective sparing (SPA) of contralateral hippocampus, neural stem cell compartment (NSC) and limbic circuit. We prepared four PBRT treatment plans for four patients with high-grade gliomas (60Gy in 30 fractions delivered to planning treatment volume (PTV60Gy)). For all plans, a structure denoted 'uninvolved brain' was created, which included all brain tissue not part of PTV or standard (STD) organs at risk (OAR). No dosimetric constraints were included for uninvolved brain. Selective SPA plans were prepared with IMRT and HT; contralateral hippocampus, NSC and limbic circuit were contoured; and dosimetric constraints were entered for these structures without compromising dose to PTV or STD OAR. We compared V100 and D95 for PTV46Gy and PTV60Gy, and ID brain for all plans. There were no significant differences in V100 and D95 for PTV46Gy and PTV60Gy. ID brain was lower in traditional IMRT versus HT plans for STD and SPA plans (mean ID brain 23.64Gy vs. 28Gy and 18.7Gy vs. 24.5Gy, respectively) and in SPA versus STD plans both with IMRT and HT (18.7Gy vs. 23.64Gy and 24.5Gy vs. 28Gy, respectively). n the setting of PBRT for high-grade gliomas, IMRT reduces ID brain compared with HT with or without selective SPA of contralateral hippocampus, limbic circuit and NSC, and the use of selective SPA reduces ID brain compared with STD PBRT delivered with either traditional IMRT or HT.

  7. SU-E-T-417: The Impact of Normal Tissue Constraints On PTV Dose Homogeneity for Intensity Modulated Radiotherapy (IMRT), Volume Modulated Arc Therapy (VMAT) and Tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Peng, J; McDonald, D; Ashenafi, M; Ellis, A; Vanek, K [Medical University of South Carolina, Charleston, SC (United States)

    2014-06-01

    Purpose: Complex intensity modulated arc therapy tends to spread low dose to normal tissue(NT)regions to obtain improved target conformity and homogeneity and OAR sparing.This work evaluates the trade-offs between PTV homogeneity and reduction of the maximum dose(Dmax)spread to NT while planning of IMRT,VMAT and Tomotherapy. Methods: Ten prostate patients,previously planned with step-and-shoot IMRT,were selected.To fairly evaluate how PTV homogeneity was affected by NT Dmax constraints,original IMRT DVH objectives for PTV and OARs(femoral heads,and rectal and bladder wall)applied to 2 VMAT plans in Pinnacle(V9.0), and Tomotherapy(V4.2).The only constraint difference was the NT which was defined as body contours excluding targets,OARs and dose rings.NT Dmax constraint for 1st VMAT was set to the prescription dose(Dp).For 2nd VMAT(VMAT-NT)and Tomotherapy,it was set to the Dmax achieved in IMRT(~70-80% of Dp).All NT constraints were set to the lowest priority.Three common homogeneity indices(HI),RTOG-HI=Dmax/Dp,moderated-HI=D95%/D5% and complex-HI=(D2%-D98%)/Dp*100 were calculated. Results: All modalities with similar dosimetric endpoints for PTV and OARs.The complex-HI shows the most variability of indices,with average values of 5.9,4.9,9.3 and 6.1 for IMRT,VMAT,VMAT-NT and Tomotherapy,respectively.VMAT provided the best PTV homogeneity without compromising any OAR/NT sparing.Both VMAT-NT and Tomotherapy,planned with more restrictive NT constraints,showed reduced homogeneity,with VMAT-NT showing the worst homogeneity(P<0.0001)for all HI.Tomotherapy gave the lowest NT Dmax,with slightly decreased homogeneity compared to VMAT. Finally, there was no significant difference in NT Dmax or Dmean between VMAT and VMAT-NT. Conclusion: PTV HI is highly dependent on permitted NT constraints. Results demonstrated that VMAT-NT with more restrictive NT constraints does not reduce Dmax NT,but significantly receives higher Dmax and worse target homogeneity.Therefore, it is critical

  8. Monte Carlo computed machine-specific correction factors for reference dosimetry of TomoTherapy static beam for several ion chambers

    International Nuclear Information System (INIS)

    Sterpin, E.; Mackie, T. R.; Vynckier, S.

    2012-01-01

    Purpose: To determine k Q msr ,Q o f msr ,f o correction factors for machine-specific reference (msr) conditions by Monte Carlo (MC) simulations for reference dosimetry of TomoTherapy static beams for ion chambers Exradin A1SL, A12; PTW 30006, 31010 Semiflex, 31014 PinPoint, 31018 microLion; NE 2571. Methods: For the calibration of TomoTherapy units, reference conditions specified in current codes of practice like IAEA/TRS-398 and AAPM/TG-51 cannot be realized. To cope with this issue, Alfonso et al. [Med. Phys. 35, 5179–5186 (2008)] described a new formalism introducing msr factors k Q msr ,Q o f msr ,f o for reference dosimetry, applicable to static TomoTherapy beams. In this study, those factors were computed directly using MC simulations for Q 0 corresponding to a simplified 60 Co beam in TRS-398 reference conditions (at 10 cm depth). The msr conditions were a 10 × 5 cm 2 TomoTherapy beam, source-surface distance of 85 cm and 10 cm depth. The chambers were modeled according to technical drawings using the egs++ package and the MC simulations were run with the egs c hamber user code. Phase-space files used as the source input were produced using PENELOPE after simulation of a simplified 60 Co beam and the TomoTherapy treatment head modeled according to technical drawings. Correlated sampling, intermediate phase-space storage, and photon cross-section enhancement variance reduction techniques were used. The simulations were stopped when the combined standard uncertainty was below 0.2%. Results: Computed k Q msr ,Q o f msr ,f o values were all close to one, in a range from 0.991 for the PinPoint chamber to 1.000 for the Exradin A12 with a statistical uncertainty below 0.2%. Considering a beam quality Q defined as the TPR 20,10 for a 6 MV Elekta photon beam (0.661), the additional correction k Q msr, Q f msr, f ref to k Q,Q o defined in Alfonso et al. [Med. Phys. 35, 5179–5186 (2008)] formalism was in a range from 0.997 to 1.004.Conclusion: The MC computed

  9. Biot-Savart helicity versus physical helicity: A topological description of ideal flows

    Science.gov (United States)

    Sahihi, Taliya; Eshraghi, Homayoon

    2014-08-01

    For an isentropic (thus compressible) flow, fluid trajectories are considered as orbits of a family of one parameter, smooth, orientation-preserving, and nonsingular diffeomorphisms on a compact and smooth-boundary domain in the Euclidian 3-space which necessarily preserve a finite measure, later interpreted as the fluid mass. Under such diffeomorphisms the Biot-Savart helicity of the pushforward of a divergence-free and tangent to the boundary vector field is proved to be conserved and since these circumstances present an isentropic flow, the conservation of the "Biot-Savart helicity" is established for such flows. On the other hand, the well known helicity conservation in ideal flows which here we call it "physical helicity" is found to be an independent constant with respect to the Biot-Savart helicity. The difference between these two helicities reflects some topological features of the domain as well as the velocity and vorticity fields which is discussed and is shown for simply connected domains the two helicities coincide. The energy variation of the vorticity field is shown to be formally the same as for the incompressible flow obtained before. For fluid domains consisting of several disjoint solid tori, at each time, the harmonic knot subspace of smooth vector fields on the fluid domain is found to have two independent base sets with a special type of orthogonality between these two bases by which a topological description of the vortex and velocity fields depending on the helicity difference is achieved since this difference is shown to depend only on the harmonic knot parts of velocity, vorticity, and its Biot-Savart vector field. For an ideal magnetohydrodynamics (MHD) flow three independent constant helicities are reviewed while the helicity of magnetic potential is generalized for non-simply connected domains by inserting a special harmonic knot field in the dynamics of the magnetic potential. It is proved that the harmonic knot part of the vorticity

  10. Prevalence of myofascial chronic pelvic pain and the effectiveness of pelvic floor physical therapy.

    Science.gov (United States)

    Bedaiwy, Mohamed A; Patterson, Betsy; Mahajan, Sangeeta

    2013-01-01

    To determine the prevalence of myofascial pain and the outcome of transvaginal pelvic floor physical therapy for the treatment of chronic pelvic pain caused by myofascial pelvic pain in a tertiary care facility. A retrospective chart review was performed on all women who presented to our facility between January 2005 and December 2007. Those diagnosed with myofascial pelvic pain and referred for transvaginal pelvic floor physical therapy over this 3-year period were evaluated. Participants with an initial pain score of > or = 4, myofascial pelvic pain on examination, and who attended 2 or more physician visits were included in the analysis. Patient physical examination findings, symptoms, and verbal pain ratings were reviewed. In all, 146 (13.2%) of 1,106 initially screened patients were diagnosed with myofascial pain. Seventy-five (51%) of the 146 patients who were referred for physical therapy were included, and 75% had an initial pain score of > or = 7. Pain scores significantly improved proportional to the number of physical therapy visits completed, with 63% of patients reporting significant pain improvement. Transvaginal physical therapy is an effective treatment for chronic pelvic pain resulting from myofascial pelvic pain.

  11. Chronic female pelvic pain

    Directory of Open Access Journals (Sweden)

    Gaurab Maitra

    2013-01-01

    Full Text Available Chronic pelvic pain (CPP is defined as nonmalignant pain perceived in the structures related to the pelvis that has been present for more than 6 months or a non acute pain mechanism of shorter duration. Pain in the pelvic region can arise from musculoskeletal, gynaecological, urologic, gastrointestinal and or neurologic conditions. Key gynaecological conditions that contribute to CPP include pelvic inflammatory disease (PID, endometriosis, adnexa pathologies (ovarian cysts, ovarian remnant syndrome, uterine pathologies (leiomyoma, adenomyosis and pelvic girdle pain associated with pregnancy. Several major and minor sexually transmitted diseases (STD can cause pelvic and vulvar pain. A common painful condition of the urinary system is Interstitial cystitis(IC. A second urologic condition that can lead to development of CPP is urethral syndrome. Irritable bowel syndrome (IBS is associated with dysmenorrhoea in 60% of cases. Other bowel conditions contributing to pelvic pain include diverticular disease,Crohn′s disease ulcerative colitis and chronic appendicitis. Musculoskeletal pathologies that can cause pelvic pain include sacroiliac joint (SIJ dysfunction, symphysis pubis and sacro-coccygeal joint dysfunction, coccyx injury or malposition and neuropathic structures in the lower thoracic, lumbar and sacral plexus. Prolonged pelvic girdle pain, lasting more than 6 months postpartum is estimated in 3% to 30% of women. Nerve irritation or entrapment as a cause of pelvic pain can be related to injury of the upper lumbar segments giving rise to irritation of the sensory nerves to the ventral trunk or from direct trauma from abdominal incisions or retractors used during abdominal surgical procedures. Afflictions of the iliohypogastric, ilioinguinal, genitofemoral, pudendal and obturator nerves are of greatest concern in patients with pelvic pain. Patient education about the disease and treatment involved is paramount. A knowledge of the differential

  12. Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields

    Science.gov (United States)

    McNiven, Andrea L.

    The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the

  13. Bearing capacity of helical pile foundation in peat soil from different, diameter and spacing of helical plates

    Science.gov (United States)

    Fatnanta, F.; Satibi, S.; Muhardi

    2018-03-01

    In an area dominated by thick peat soil layers, driven piles foundation is often used. These piles are generally skin friction piles where the pile tips do not reach hard stratum. Since the bearing capacity of the piles rely on the resistance of their smooth skin, the bearing capacity of the piles are generally low. One way to increase the bearing capacity of the piles is by installing helical plates around the pile tips. Many research has been performed on helical pile foundation. However, literature on the use of helical pile foundation on peat soil is still hardly found. This research focus on the study of axial bearing capacity of helical pile foundation in peat soil, especially in Riau Province. These full-scale tests on helical pile foundation were performed in a rectangular box partially embedded into the ground. The box is filled with peat soil, which was taken from Rimbo Panjang area in the district of Kampar, Riau Province. Several helical piles with different number, diameter and spacing of the helical plates have been tested and analysed. The tests result show that helical pile with three helical plates of uniform diameter has better bearing capacity compared to other helical piles with varying diameter and different number of helical plates. The bearing capacity of helical pile foundation is affected by the spacing between helical plates. It is found that the effective helical plates spacing for helical pile foundation with diameter of 15cm to 35cm is between 20cm to 30cm. This behaviour may be considered to apply to other type of helical pile foundations in peat soil.

  14. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.

    Science.gov (United States)

    Schwarz, Timo Julian; Weber, Markus; Dornia, Christian; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Craiovan, Benjamin

    2017-09-01

    Purpose  Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method  In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results  The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion  Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points   · Pelvic tilt and rotation influence cup

  15. Emergencies in the retroperitoneum: assessment of spread of disease by helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Scialpi, M. E-mail: michelescialpi@libero.it; Scaglione, M.; Angelelli, G.; Lupattelli, L.; Resta, M.C.; Resta, M.; Rotondo, A

    2004-04-01

    Acute pancreatitis, leaking abdominal aortic aneurysm, and renal trauma frequently occur in the setting of patients with abdominal nontraumatic and traumatic injury; it represents the most urgent conditions that may determine the presence of fluid collections or haematoma in the retroperitoneum. Single spiral CT and multidetector-row CT (MDCT) play an important role in diagnosis of retroperitoneal emergencies, providing useful informations on the type, site, extent and management of the fluid collections. An accurate CT assessment requires the awareness of the existence of dissectable retroperitoneal fascial planes. Fluid collections or haematoma tends to escape the retroperitoneal site of origin into planes extend from the diaphragm to the pelvic floor. We assess the multicompartimental anatomy of the retroperitoneum and the pathway of spread of the most frequent retroperitoneal fluid collections or haematoma by helical CT.

  16. Assessment of a semiautomated pelvic floor measurement model for evaluating pelvic organ prolapse on MRI.

    Science.gov (United States)

    Onal, S; Lai-Yuen, S; Bao, P; Weitzenfeld, A; Greene, K; Kedar, R; Hart, S

    2014-06-01

    The objective of this study was to assess the performance of a semiautomated pelvic floor measurement algorithmic model on dynamic magnetic resonance imaging (MRI) images compared with manual pelvic floor measurements for pelvic organ prolapse (POP) evaluation. We examined 15 MRIs along the midsagittal view. Five reference points used for pelvic floor measurements were identified both manually and using our semiautomated measurement model. The two processes were compared in terms of accuracy and precision. The semiautomated pelvic floor measurement model provided highly consistent and accurate locations for all reference points on MRI. Results also showed that the model can identify the reference points faster than the manual-point identification process. The semiautomated pelvic floor measurement model can be used to facilitate and improve the process of pelvic floor measurements on MRI. This will enable high throughput analysis of MRI data to improve the correlation analysis with clinical outcomes and potentially improve POP assessment.

  17. Hypofractionated radiotherapy for primary or secondary oligometastatic lung cancer using Tomotherapy

    Directory of Open Access Journals (Sweden)

    Chang Heng-Jui

    2012-12-01

    Full Text Available Abstract Background To retrospectively review the outcome of patients with primary or secondary oligometastatic lung cancer, treated with hypofractionated Tomotherapy. Methods Between April 2007 and June 2011, a total of 33 patients with oligometastatic intrapulmonary lesions underwent hypofractionated radiotherapy by Tomotherapy along with appropriate systemic therapy. There were 24 primary, and 9 secondary lung cancer cases. The radiation doses ranged from 4.5 to 7.0 Gy per fraction, multiplied by 8–16 fractions. The median dose per fraction was 4.5 Gy (range, 4.5-7.0 Gy, and the median total dose was 49.5 Gy (range, 45–72 Gy. The median estimated biological effective dose at 10 Gy (BED10 was 71.8 Gy (range, 65.3–119.0 Gy, and that at 3 Gy (BED3 was 123.8 Gy (range, 112.5–233.3 Gy. The mean lung dose (MLD was constrained mainly under 1200 cGy. The median gross tumor volume (GTV was 27.9 cm3 (range: 2.5–178.1 cm3. Results The median follow-up period was 25.8 months (range, 3.0–60.7 months. The median overall survival (OS time was 32.1 months for the 24 primary lung cancer patients, and >40 months for the 9 metastatic lung patients. The median survival time of the patients with extra-pulmonary disease (EPD was 11.2 months versus >50 months (not reached in the patients without EPD (p 3 had a better survival than those with larger GTV (>27.9 cm3: >40 months versus 12.85 months (p = 0.047. The patients with ≦2 lesions had a median survival >40 months, whereas those with ≧3 lesions had 26 months (p = 0.065. The 2-year local control (LC rate was 94.7%. Only 2 patients (6.1% developed ≧grade 3 radiation pneumonitis. Conclusion Using Tomotherapy in hypofractionation may be effective for selected primary or secondary lung oligometastatic diseases, without causing significant toxicities. Pulmonary oligometastasis patients without EPD had better survival outcomes than those with

  18. A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes

    Energy Technology Data Exchange (ETDEWEB)

    Michalski, Andrea [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Central Coast Cancer Centre, Gosford Hospital, Gosford, New South Wales (Australia); Atyeo, John, E-mail: john.atyeo@sydney.edu.au [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Cox, Jennifer [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia); Rinks, Marianne [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Radiation Oncology, Cancer Services, Illawarra Shoalhaven Local Health District, Wollongong, New South Wales (Australia); Morgia, Marita; Lamoury, Gillian [Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia)

    2014-07-01

    Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. All patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D

  19. Pelvic exenteration for locally advanced primary and recurrent pelvic neoplasm: a series of 54 resectable cases

    Directory of Open Access Journals (Sweden)

    Sergio Renato Pais Costa

    2008-09-01

    Full Text Available Objective: To report on a series of 54 patients with pelvic neoplasms submitted to curative pelvic exenteration at a tertiary hospital and describe the results (morbidity, mortality, and long-term survival. Methods: The complete data of 54 patients submitted to pelvic exenteration between 1999 and 2007 were evaluated. Sixteen men and 38 women with a mean age of 65 years and median age of 66 years (36 to 77 were studied. Surgical procedures included total pelvic exenteration (n = 26, anterior pelvic exenteration(n = 5, and posterior pelvic exenteration (n = 23. Rresults: The mean operative time was 402 minutes (280 to 585. The average volume of intraoperative bleeding was 2,013 ml (300 to 5,800. Postoperative mortality was 5% (n = 3. The overall morbidity rate was 46%(n = 25. Histological evaluation demonstrated that 47 resections were R0 (87% while seven were R1 (13%. The overall survival rate in five years was 23.5% (n = 12. Cconclusions: Despite its aggressive nature and high morbidity, pelvic exenteration is still justified in locally advanced pelvic neoplasms or even in isolated pelvic recurrence, since it affords a greater long-term control of the neoplasm.

  20. [Functional aspects of pelvic floor surgery].

    Science.gov (United States)

    Wagenlehner, F M E; Gunnemann, A; Liedl, B; Weidner, W

    2009-11-01

    Pelvic floor dysfunctions are frequently seen in females. The human pelvic floor is a complex structure and heavily stressed throughout female life. Recent findings in the functional anatomy of the pelvic floor have led to a much better understand-ing, on the basis of which enormous improvements in the therapeutic options have arisen. The pelvic floor activity is regulated by three main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor -organs, bladder and rectum. For different reasons laxity in the vagina or its supporting ligaments as a result of altered connective tissue can distort this functional anatomy. A variety of symptoms can derive from these pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, faecal incontinence, obstructive bowel disease syndrome and pelvic pain. Pelvic floor reconstruction is nowadays driven by the concept that in the case of pelvic floor symptoms restoration of the anatomy will translate into restoration of the physiology and ultimately improve the patients' symptoms. The exact surgical reconstruction of the anatomy is there-fore almost exclusively focused on the restoration of the lax pelvic floor ligaments. An exact identification of the anatomic lesions preoperatively is eminently necessary, to allow for an exact anatomic reconstruction with respect to the muscular forces of the pelvic floor. Georg Thieme Verlag Stuttgart * New York.

  1. Tomotherapy archive structure and new software tool for loading and advanced analysis of data contained in it

    International Nuclear Information System (INIS)

    Ryczkowski, A.; Piotrowski, T.

    2011-01-01

    Aim: The main objective of the study was to analyze the structure of data contained in the archives exported from a tomotherapy treatment planning system. An additional aim was to create an application equipped with a user-friendly interface to enable automatic reading of files and data analysis, also using external algorithms. Analyses had to include image registration, dose deformation and summation. Materials and methods: Files from the archive exported from the tomotherapy treatment planning system (TPS) were analyzed. Two programs were used to analyze the information contained in the archive files: XML Viewer by Mind Fusion Limited and H x D hex editor by Mael Hora. To create an application enabling loading and analyzing the data, Matlab by MathWorks, version R2009b, was used. Results: Archive exported from the TPS is a directory with several files. It contains three types of data: .xml, .img and .sin. Tools available in Matlab offer great opportunities for analysis and transformation of loaded information. Proposed application automates the loading of necessary information and simplifies data handling. Furthermore, the application is equipped with a graphical user interface (GUI). The main application window contains buttons for opening the archives and analyzing the loaded data. Conclusion: The analysis of data contained in the archive exported from the tomotherapy treatment planning system allowed to determine the way and place of saving information of our interest, such as tomography images, structure sets and dose distributions. This enabled us to develop and optimize methods of loading and analyzing this information. (authors)

  2. Pelvic denervation procedures for dysmenorrhea.

    Science.gov (United States)

    Ramirez, Christina; Donnellan, Nicole

    2017-08-01

    Chronic pelvic pain and dysmenorrhea are common conditions affecting reproductive-age women. Surgical pelvic denervation procedures may be a treatment option for women with midline dysmenorrhea, in which medical management is declined by the patient, ineffective at managing symptoms, or medically contraindicated. This review describes the surgical techniques and complications associated with pelvic denervation procedures as well as the current evidence for these procedures in women with primary dysmenorrhea and dysmenorrhea secondary to endometriosis. Presacral neurectomy is the preferred pelvic denervation procedure in patients with primary dysmenorrhea and midline chronic pelvic pain associated with endometriosis. In patients with endometriosis presacral neurectomy is a useful adjunct to excision or ablation of all endometrial lesions to improve postoperative pain relief. There is no additional patient benefit of performing combined presacral neurectomy and uterine nerve ablation procedures. Pelvic denervation procedures can be performed safely and quickly with a low risk of complication if the surgeon is knowledgeable and skilled in operating in the presacral space. Patients should be adequately counseled on expected success rates and potential complications associated with pelvic denervation procedures.

  3. Concept and development of measurement method of time sensitivity profile (TSP) in X-ray CT. Comparison of non-helical, single-slice helical, and multi-slice helical scans

    International Nuclear Information System (INIS)

    Tsujioka, Katsumi; Ida, Yoshihiro; Ohtsubo, Hironori; Takahashi, Yasukata; Niwa, Masayoshi

    2000-01-01

    We focused on the time element contained in a single CT image, and devised the concept of a time-sensitivity profile (TSP) describing how the time element is translated into an image. We calculated the data collection time range when the helical pitch is changed in non helical scans, single slice helical scans, and multi slice helical scans. We then calculated the time sensitivity profile (TSP) from the weighting applied when the data collection time range is translated into an image. TSP was also measured for each scanning method using our self-made moving phantom. TSPs obtained from the calculation and the experiments were very close. TSP showed interesting characteristics with each scanning method, especially in the case of multi slice helical scanning, in which TSP became shorter as helical pitch increased. We referred to the TSP's FWHM as the effective scanning time. When we conducted multi slice helical scanning at helical pitch 3, the effective scanning time increased to about 24% longer than that of a non helical scan. When we conducted multi slice helical scanning at helical pitch 5 or 6, the effective scanning time was about half that of a non helical scan. The time sensitivity profile (TSP) is a totally new concept that we consider an important element in discussing the time resolution of a CT scanner. The results of this review will provide significant data in determining the scanning parameters when scanning a moving object. (author)

  4. Pelvic floor physical therapy in urogynecologic disorders.

    Science.gov (United States)

    Kotarinos, Rhonda K

    2003-08-01

    Physical therapists are uniquely qualified to treat pelvic floor dysfunction with conservative management techniques. Techniques associated with incontinence and support functions of the pelvic floor include bladder training and pelvic floor rehabilitation: pelvic floor exercises, biofeedback therapy, and pelvic floor electrical stimulation. Pain associated with mechanical pelvic floor dysfunction can be treated by physical therapists utilizing various manual techniques and modalities. Research documents that conservative management is effective in treating many conditions associated with pelvic floor dysfunction. Research should be conducted to determine if addressing diastasis recti and contracture of the pelvic floor musculature should be a component of the standard physical therapy protocol.

  5. 4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yong, E-mail: hu.yong@zs-hospital.sh.cn; Zhou, Yong-Kang, E-mail: zhouyk2009@163.com; Chen, Yi-Xing, E-mail: chen.yixing@zs-hospital.sh.cn; Shi, Shi-Ming, E-mail: shiming32@126.com; Zeng, Zhao-Chong, E-mail: zeng.zhaochong@zs-hospital.sh.cn [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, 180 Feng Lin Road, Shanghai 200032 (China)

    2016-07-15

    Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area between the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z

  6. Awareness and timing of pelvic floor muscle contraction, pelvic exercises and rehabilitation of pelvic floor in lifelong premature ejaculation: 5 years experience

    Directory of Open Access Journals (Sweden)

    Giuseppe La Pera

    2014-06-01

    Full Text Available Objectives: To assess the cure rate of patients with premature ejaculation who underwent a treatment involving: 1 awareness of the pelvic floor muscles 2 learning the timing of execution and maintenance of contraction of the pelvic floor muscles during the sensation of the pre-orgasmic phase 3 pelvic floor rehabilitation (bio feed back, pelvic exercises and electrostimulation. Materials and methods: We recruited 78 patients with lifelong premature ejaculation who completed the training. The patients were informed of the role of the pelvic floor. They were taught to carry out the execution and maintenance of contraction of the pelvic floor muscles during the sensation of the pre-orgasmic phase to control the ejaculatory reflex. In order to improve the awareness, the tone and the endurance of the pelvic floor muscles, patients were treated with the rehabilitation of pelvic floor (RPF consisting mainly in biofeedback, pelvic exercises and in some cases also in electro-stimulation (ES. The training was carried out for a period of about 2-6 months with an average of 2-5 visits per cycle. Results: 54% of patients who completed the training were cured of premature ejaculation and learned over time to be able to postpone the ejaculation reflex. In a subgroup of 26 patients was also measured the IELT which on the average increased from < 2 minutes to >10 minutes. The best results occurred mainly in patients aged less than 35 where the cure rate was 65%. There were no side effects. Conclusions: In this study, approximately half of patients with premature ejaculation were cured after applying the above treatment.This therapy, necessitates a fairly long period of time (2-6 months and a great commitment on the part of the patient, nevertheless it can be a valid and effective treatment for patients with premature ejaculation. This treatment makes the patient independent in that he is not bound to specific times for taking medication. Furthermore there are no

  7. Anorectal and Pelvic Pain.

    Science.gov (United States)

    Bharucha, Adil E; Lee, Tae Hee

    2016-10-01

    Although pelvic pain is a symptom of several structural anorectal and pelvic disorders (eg, anal fissure, endometriosis, and pelvic inflammatory disease), this comprehensive review will focus on the 3 most common nonstructural, or functional, disorders associated with pelvic pain: functional anorectal pain (ie, levator ani syndrome, unspecified anorectal pain, and proctalgia fugax), interstitial cystitis/bladder pain syndrome, and chronic prostatitis/chronic pelvic pain syndrome. The first 2 conditions occur in both sexes, while the latter occurs only in men. They are defined by symptoms, supplemented with levator tenderness (levator ani syndrome) and bladder mucosal inflammation (interstitial cystitis). Although distinct, these conditions share several similarities, including associations with dysfunctional voiding or defecation, comorbid conditions (eg, fibromyalgia, depression), impaired quality of life, and increased health care utilization. Several factors, including pelvic floor muscle tension, peripheral inflammation, peripheral and central sensitization, and psychosocial factors, have been implicated in the pathogenesis. The management is tailored to symptoms, is partly supported by clinical trials, and includes multidisciplinary approaches such as lifestyle modifications and pharmacological, behavioral, and physical therapy. Opioids should be avoided, and surgical treatment has a limited role, primarily in refractory interstitial cystitis. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  8. Pulling Helices inside Bacteria: Imperfect Helices and Rings

    Science.gov (United States)

    Allard, Jun F.; Rutenberg, Andrew D.

    2009-04-01

    We study steady-state configurations of intrinsically-straight elastic filaments constrained within rod-shaped bacteria that have applied forces distributed along their length. Perfect steady-state helices result from axial or azimuthal forces applied at filament ends, however azimuthal forces are required for the small pitches observed for MreB filaments within bacteria. Helix-like configurations can result from distributed forces, including coexistence between rings and imperfect helices. Levels of expression and/or bundling of the polymeric protein could mediate this coexistence.

  9. A comparison between stabilization exercises and pelvic floor muscle training in women with pelvic organ prolapse

    Directory of Open Access Journals (Sweden)

    Nuriye Özengin

    2015-03-01

    Full Text Available Objective: This study aimed to compare the effectiveness of stabilization exercises and pelvic floor muscle training in women with stage 1 and 2 pelvic organ prolapse. Materials and Methods: In a total 38 women with pelvic organ prolapse whose average age was 45.60 years, pelvic floor muscles were evaluated with electromyography, and prolapse with pelvic organ prolapse quantification system, and the quality of life with prolapse quality of life questionnaire. Afterwards, the subjects were divided into two groups; stabilization exercise group (n=19 and pelvic floor muscle training group (n=19. Stabilization exercise group were given training for 8 weeks, 3 times a week. Pelvic floor muscle training group were given eight-week home exercises. Each group was assessed before training and after eight weeks. Results: An increase was found in the pelvic muscle activation response in the 2 groups (p≤0.05. There was no difference in EMG activity values between the groups (p>0.05. A difference was found in the values Aa, Ba and C in subjects of each group (p≤0.05, and the TVL, Ap, Bp and D values of subjects in pelvic floor muscle training group (p≤0.05 in the before and after pelvic organ prolapse quantification system assessment, however, no difference was found between the groups (p≤0.05. A positive difference was found in the effect of prolapse sub parameter in each of the two groups, and in general health perception sub parameter in subjects of stabilization exercise group (p<0.05 in the prolapse quality of life questionnaire. Conclusions: It was concluded that both training programs increased the pelvic floor muscle strength, provided a decline in prolapse stages. Stabilization exercise has increased general health perception unlike home training, thus, these exercises can be added to the treatment of women with prolapse.

  10. SU-F-P-11: Long Term Dosimetric Stability of 6 TomoTherapy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Smilowitz, J; Dunkerley, D; Geurts, M; Hill, P; Yadav, P [University of Wisconsin, Madison, WI (United States)

    2016-06-15

    Purpose: The dosimetric stability of six TomoTherapy units was analyzed to investigate changes in performance over time and with system upgrades. Methods: Energy and output were tracked using monitor chamber signal, onboard MVCT detector signal and external ion chamber measurements. The systems (and monitoring periods) include 3 Hi-Art (67, 61 and 65 mos.), 2 HDA (29 and 25 mos.) and one research unit (7 mo.). Dose Control Stability system (DCS) was installed on 4 systems. Output stability is reported as deviation from reference monitor chamber signal for all systems, and from an external chamber for 4 systems. Energy stability was monitored using the relative (center versus off-axis) MVCT detector signal and/or the ratio of chamber measurements at 2 depths. The results from the clinical systems were used to benchmark the stability of the research unit, which has the same linear accelerator but runs at a higher dose rate. Results: The output based on monitor chamber data of all six systems is very stable. Non- DCS had a standard deviation of 1.7% and 1.8%. As expected, DCS systems had improved standard deviation: 0.003–0.05%. The energy was also very stable for all units. The standard deviation in exit detector flatness was 0.02–0.3%. Ion chamber output and 20/10 cm ratios supported these results. The stability for the research system, as monitored with a variety of metrics, is on par with the existing systems. Conclusion: The output and energy of six TomoTherapy units over a total of almost 10 years is quite stable. For each system, the results are consistent between the different measurement tools and techniques, proving not only the dosimetric stability, but that these quality parameters can be confirmed with various metrics. A research unit operating at a higher dose rate performed as well as the clinical treatment units. University of Wisconsin and Accuray Inc. (vendor of TomoTherapy systems) have a research agreement which supplies funds for research to

  11. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tome, Wolfgang A. [Department of Human Oncology, University of Wisconsin-Madison, WI, 53792 (United States); Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC 3002 (Australia) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Human Oncology, University of Wisconsin-Madison, WI 53792 (United States); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia) and Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Einstein Institute of Oncophysics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York 10461 (United States) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2012-08-15

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  12. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tomé, Wolfgang A.

    2012-01-01

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed “Super Sampling” involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  13. Pelvic Insufficiency Fracture After Pelvic Radiotherapy for Cervical Cancer: Analysis of Risk Factors

    International Nuclear Information System (INIS)

    Oh, Dongryul; Huh, Seung Jae; Nam, Heerim; Park, Won; Han, Youngyih; Lim, Do Hoon; Ahn, Yong Chan; Lee, Jeong Won; Kim, Byoung Gie; Bae, Duk Soo; Lee, Je Ho

    2008-01-01

    Purpose: To investigate the incidence, clinical characteristics, and risk factors of pelvic insufficiency fracture (PIF) after pelvic radiotherapy (RT) in cervical cancer. Methods and Materials: Medical records and imaging studies, including bone scintigraphy, CT, and MRI of 557 patients with cervical cancer who received whole-pelvic RT between January 1998 and August 2005 were reviewed. Results: Eighty-three patients were diagnosed as having PIF after pelvic RT. The 5-year cumulative incidence of PIF was 19.7%. The most commonly involved site was the sacroiliac joint. Pelvic pain developed in 48 patients (57.8%) at diagnosis. Eleven patients (13.3%) needed admission or narcotics because of severe pain, and others had good relief of symptoms with conservative management. In univariate analysis, age ≥55 years (p < 0.001), anteroposterior/posteroanterior parallel opposing technique (p = 0.001), curative treatment (p < 0.001), and radiation dose ≥50.4 Gy (p = 0.005) were the predisposing factors for development of PIF. Concurrent chemotherapy (p = 0.78) was not significant. Multivariate analysis showed that age ≥55 years (p < 0.001), body weight <55 kg (p = 0.02), curative treatment (p = 0.03), and radiation dose ≥50.4 Gy (p = 0.04) were significant predisposing factors for development of PIF. Conclusion: The development of PIF is not rare after pelvic RT. The use of multibeam arrangements to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture, especially in elderly women with low body weight

  14. Helical system. History and current state of helical research

    International Nuclear Information System (INIS)

    Yokoyama, Masayuki

    2017-01-01

    This paper described the following: (1) history of nuclear fusion research of Japan's original heliotron method, (2) worldwide development of nuclear fusion research based on helical system such as stellarator, and (3) worldwide meaning of large helical device (LHD) aiming to demonstrate the steady-state performance of heliotron type in the parameter area extrapolable to the core plasma, and research results of LHD. LHD demonstrated that the helical system is excellent in steady operation performance at the world's most advanced level. In an experiment using deuterium gas in 2017, LHD achieved to reach 120 million degrees of ion temperature, which is one index of nuclear fusion condition, demonstrated the realization of high-performance plasma capable of extrapolating to future nuclear fusion reactors, and established the foundation for full-scale research toward the realization of nuclear fusion reactor. Besides experimental research, this paper also described the helical-type stationary nuclear fusion prototype reactor, FFHR-d1, which was based on progress of large-scale simulation at the world's most advanced level. A large-scale superconducting stellarator experimental device, W7-X, with the same scale as LHD, started experiment in December 2015, whose current state is also touched on here. (A.O.)

  15. Recalculation of dose for each fraction of treatment on TomoTherapy.

    Science.gov (United States)

    Thomas, Simon J; Romanchikova, Marina; Harrison, Karl; Parker, Michael A; Bates, Amy M; Scaife, Jessica E; Sutcliffe, Michael P F; Burnet, Neil G

    2016-01-01

    The VoxTox study, linking delivered dose to toxicity requires recalculation of typically 20-37 fractions per patient, for nearly 2000 patients. This requires a non-interactive interface permitting batch calculation with multiple computers. Data are extracted from the TomoTherapy(®) archive and processed using the computational task-management system GANGA. Doses are calculated for each fraction of radiotherapy using the daily megavoltage (MV) CT images. The calculated dose cube is saved as a digital imaging and communications in medicine RTDOSE object, which can then be read by utilities that calculate dose-volume histograms or dose surface maps. The rectum is delineated on daily MV images using an implementation of the Chan-Vese algorithm. On a cluster of up to 117 central processing units, dose cubes for all fractions of 151 patients took 12 days to calculate. Outlining the rectum on all slices and fractions on 151 patients took 7 h. We also present results of the Hounsfield unit (HU) calibration of TomoTherapy MV images, measured over an 8-year period, showing that the HU calibration has become less variable over time, with no large changes observed after 2011. We have developed a system for automatic dose recalculation of TomoTherapy dose distributions. This does not tie up the clinically needed planning system but can be run on a cluster of independent machines, enabling recalculation of delivered dose without user intervention. The use of a task management system for automation of dose calculation and outlining enables work to be scaled up to the level required for large studies.

  16. Review of the helicity formalism

    International Nuclear Information System (INIS)

    Barreiro, F.; Cerrada, M.; Fernandez, E.

    1972-01-01

    Our purpose in these notes has been to present a brief and general review of the helicity formalism. We begin by discussing Lorentz invariance, spin and helicity ideas, in section 1 . In section 2 we deal with the construction of relativistic states and scattering amplitudes in the helicity basis and we study their transformation properties under discrete symmetries. Finally we present some more sophisticated topics like kinematical singularities of helicity amplitudes, kinematical constraints and crossing relations 3, 4, 5 respectively. (Author) 8 refs

  17. Post Pelvic Radiotherapy Bony Changes

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Seung Jae [Samsung Medical Center, Seoul (Korea, Republic of)

    2009-03-15

    There has been recent interest in radiation-induced bone injury in clinical conditions, especially for pelvic insufficiency fracture (PIF). A PIF is caused by the effect of normal or physiological stress on bone with demineralization and decreased elastic resistance. Pelvic radiotherapy (RT) can also contribute to the development of a PIF. A PIF has been regarded as a rare complication with the use of megavoltage equipment. However, recent studies have reported the incidence of PIFs as 8.2{approx}20% after pelvic RT in gynecological patients, an incidence that was higher than previously believed. The importance of understanding a PIF lies in the potential for misdiagnosis as a bony metastasis. If patients complain of pelvic pain after whole-pelvis radiation therapy, the presence of a PIF must be considered in the differential diagnosis. The use of multibeam arrangements and conformal RT to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture. In addition to a PIF, osteonecrosis and avascular necrosis of the femoral head can develop after radiation therapy. Osteoradionecrosis of the pelvic bone is a clinical diagnostic challenge that must be differentiated from an osseous metastasis. A post-radiation bone sarcoma can result as a long-term sequela of pelvic irradiation for uterine cervical cancer.

  18. A note on helicity

    International Nuclear Information System (INIS)

    Bialynicki-Birula, I.; Newmann, E.T.; Porter, J.; Winicour, J.; Lukacs, B.; Perjes, Z.; Sebestyen, A.

    1981-03-01

    The authors give a formal definition of the helicity operator for integral spin fields, which does not involve their momentum-space decomposition. The discussion is based upon a representation of the Pauli-Lubanski operator in terms of the action on tensor fields by the Killing vectors associated with the generators of the Poincare group. This leads to an identification of the helicity operator with the duality operator defined by the space-time alternating tensor. Helicity eigenstates then correspond to self-dual or anti-self-dual fields, in agreement with usage implicit in the literature. In addiition, the relationship between helicity eigenstates which are intrinsically non-classical, and states of right or left circular polarization in classical electrodynamics are discussed. (author)

  19. Generalized helicity and its time derivative

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Marklin, G.J.

    1985-01-01

    Spheromaks can be sustained against resistive decay by helicity injection because they tend to obey the minimum energy principle. This principle states that a plasma-laden magnetic configuration will relax to a state of minimum energy subject to the constraint that the magnetic helicity is conserved. Use of helicity as a constraint on the minimization of energy was first proposed by Woltjer in connection with astrophysical phenomena. Helicity does decay on the resistive diffusion time. However, if helicity is created and made to flow continuoiusly into a confinement geometry, these additional linked fluxes can relax and sustain the configuration indefinitely against the resistive decay. In this paper we will present an extension of the definition of helicity to include systems where B vector can penetrate the boundary and the penetration can be varying in time. We then discuss the sustainment of RFPs and spheromaks in terms of helicity injection

  20. Patterns of uterine enhancement with helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, H.; Loyer, E.M.; Charnsangavej, C. [Department of Diagnostic Radiology, Box 57, The University of Texas, M.D. Anderson Cancer Center, 1515 Holcombe Blvd. Houston, TX 77030 (United States); Minami, M. [Department of Radiology, Faculty of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo 113 (Japan)

    1998-10-01

    Objective: The purpose of this study was to evaluate the enhancement characteristics of the normal uterine body and cervix using dynamic contrast-enhanced helical CT. Methods: Thirty-eight women scheduled for pelvic CT for non-gynecologic malignancies underwent dynamic contrast-enhanced helical CT of the pelvis. Data acquisition was during the arterial phase (30-45 s after the start of injection), the parenchymal phase (90-120 s after the start of injection), and delayed phase (3-9 min after the start of injection). The images were evaluated by four radiologists for the pattern of myometrial and cervical enhancement. Correlation was made with the age and menstrual status of the patients. Results: In the uterine body, three types of enhancement were observed. Type 1 enhancement, seen in 16 patients (42%), was characterized by the visualization of a subendometrial zone of enhancement, 30-120 s after the start of injection. Eight of these patients also showed an enhancing zone in the outer myometrium. Both zones were transitory, and in all cases, the uterus became homogeneous in the delayed phase. This pattern was seen predominantly in premenopausal women with a mean age of 34 years. Type 2 enhancement, seen in 17 cases (45%), was defined by the absence of subendometrial enhancement in the early phase. Enhancement was either diffuse from the outset or originated in the outer myometrium. This pattern was seen nearly equally in premenopausal and postmenopausal women with a mean age of 40 years. Type 3 enhancement was seen in five postmenopausal patients (13%) with a mean age of 53 years and was characterized by faint diffuse enhancement. In the cervix, a zonal pattern of enhancement defining inner and outer stroma was seen in 23 patients (61%). Fifteen patients were premenopausal and eight were postmenopausal. Conclusion: In this study, we have shown a transitory zonal distribution of the contrast in the myometrium and cervix using dynamic contrast-enhanced helical CT

  1. Patterns of uterine enhancement with helical CT

    International Nuclear Information System (INIS)

    Kaur, H.; Loyer, E.M.; Charnsangavej, C.; Minami, M.

    1998-01-01

    Objective: The purpose of this study was to evaluate the enhancement characteristics of the normal uterine body and cervix using dynamic contrast-enhanced helical CT. Methods: Thirty-eight women scheduled for pelvic CT for non-gynecologic malignancies underwent dynamic contrast-enhanced helical CT of the pelvis. Data acquisition was during the arterial phase (30-45 s after the start of injection), the parenchymal phase (90-120 s after the start of injection), and delayed phase (3-9 min after the start of injection). The images were evaluated by four radiologists for the pattern of myometrial and cervical enhancement. Correlation was made with the age and menstrual status of the patients. Results: In the uterine body, three types of enhancement were observed. Type 1 enhancement, seen in 16 patients (42%), was characterized by the visualization of a subendometrial zone of enhancement, 30-120 s after the start of injection. Eight of these patients also showed an enhancing zone in the outer myometrium. Both zones were transitory, and in all cases, the uterus became homogeneous in the delayed phase. This pattern was seen predominantly in premenopausal women with a mean age of 34 years. Type 2 enhancement, seen in 17 cases (45%), was defined by the absence of subendometrial enhancement in the early phase. Enhancement was either diffuse from the outset or originated in the outer myometrium. This pattern was seen nearly equally in premenopausal and postmenopausal women with a mean age of 40 years. Type 3 enhancement was seen in five postmenopausal patients (13%) with a mean age of 53 years and was characterized by faint diffuse enhancement. In the cervix, a zonal pattern of enhancement defining inner and outer stroma was seen in 23 patients (61%). Fifteen patients were premenopausal and eight were postmenopausal. Conclusion: In this study, we have shown a transitory zonal distribution of the contrast in the myometrium and cervix using dynamic contrast-enhanced helical CT

  2. Magnetic helicity and active filament configuration

    Science.gov (United States)

    Romano, P.; Zuccarello, F.; Poedts, S.; Soenen, A.; Zuccarello, F. P.

    2009-11-01

    Context: The role of magnetic helicity in active filament formation and destabilization is still under debate. Aims: Although active filaments usually show a sigmoid shape and a twisted configuration before and during their eruption, it is unclear which mechanism leads to these topologies. In order to provide an observational contribution to clarify these issues, we describe a filament evolution whose characteristics seem to be directly linked to the magnetic helicity transport in corona. Methods: We applied different methods to determine the helicity sign and the chirality of the filament magnetic field. We also computed the magnetic helicity transport rate at the filament footpoints. Results: All the observational signatures provided information on the positive helicity and sinistral chirality of the flux rope containing the filament material: its forward S shape, the orientation of its barbs, the bright and dark threads at 195 Å. Moreover, the magnetic helicity transport rate at the filament footpoints showed a clear accumulation of positive helicity. Conclusions: The study of this event showed a correspondence between several signatures of the sinistral chirality of the filament and several evidences of the positive magnetic helicity of the filament magnetic field. We also found that the magnetic helicity transported along the filament footpoints showed an increase just before the change of the filament shape observed in Hα images. We argued that the photospheric regions where the filament was rooted might be the preferential ways where the magnetic helicity was injected along the filament itself and where the conditions to trigger the eruption were yielded.

  3. Patients with Pelvic Floor Muscle Spasm Have a Superior Response to Pelvic Floor Physical Therapy at Specialized Centers.

    Science.gov (United States)

    Polackwich, Alan Scott; Li, Jianbo; Shoskes, Daniel A

    2015-10-01

    Chronic prostatitis/chronic pelvic pain syndrome is a common condition that often requires multimodal therapy. Patients with chronic pelvic pain syndrome have a high incidence of pelvic floor spasm, which can be treated with pelvic floor physical therapy. However, this is a specialized skill. We compared outcomes of pelvic floor physical therapy as part of multimodal therapy in patients with chronic pelvic pain syndrome between those treated at our institution and elsewhere. We identified patients from our chronic pelvic pain syndrome registry with pelvic floor spasm who were seen between 2010 and 2014 for more than 1 visit. Patient phenotype was assessed with the UPOINT system and symptom severity was determined by the National Institutes of Health CPSI. A 6-point decrease in CPSI was used to define patient improvement. A total of 82 patients fit the study criteria. Mean age was 41.6 years (range 19 to 75) and median symptom duration was 24 months (range 3 to 240). Mean CPSI was 26.8 (range 10 to 41), the median number of positive UPOINT domains was 3 (range 1 to 6) and 27 patients (32.9%) were treated locally. At followup 9 patients had refused pelvic floor physical therapy, and 24 and 48 had undergone pelvic floor physical therapy elsewhere and at CCF, respectively. The mean change in CPSI was 1.11 ± 4.1 in patients who refused, -3.46 ± 6.7 in those treated elsewhere and -11.3 ± 7.0 in those treated at CCF (p physical therapy at CCF (OR 4.23, p = 0.002) and symptom duration (OR 0.52, p = 0.03) predicted improvement. Pelvic floor physical therapy can be effective for chronic pelvic pain syndrome in patients with pelvic floor spasm. However, the outcome depends on specialty training and experience of therapists. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Multispecialty retrospective review of the clinical utility of pelvic magnetic resonance imaging in the setting of pelvic pain.

    Science.gov (United States)

    Moore, John R; Pathak, Ram A; Snowden, Caroline; Bolan, Candice W; Young, Paul R; Broderick, Gregory A

    2017-12-01

    Pelvic pain is a common complaint, and management of it is often difficult. We sought to evaluate the utility of magnetic resonance imaging (MRI) in the diagnosis of male pelvic pain. Though MRIs are commonly ordered to evaluate pelvic pain, there are very few studies obtaining the efficacy of pelvic MRI in determining a definitive diagnosis. The primary aim of our study was to evaluate the clinical utility of pelvic MRI for a diagnosis code that included pain. After receiving institutional review board approval, a retrospective study was performed of all pelvic MRIs completed at our institution from January 2, 2010 to December 31, 2014. These were further delineated into ordering providers by specialty and urology-specific International Classification of Diseases, Ninth Revision (ICD-9) code diagnoses (male pelvic pain, prostatitis, groin pain, scrotal pain, testicular pain, and penile pain). Clinical utility was defined as positive if MRI findings resulted in a change in management. Subanalysis was performed on patients with an ICD-9 co-diagnosis of previous oncologic concern. A total of 2,643 pelvic MRIs were ordered at our institution over a 5-year period. Of these, 597 pelvic MRIs (23%) were ordered for a diagnosis code that included pain (hip pain, rectal pain, joint pain, penile pain, scrotal pain, male pelvic pain and orchitis). Total utility for MRIs to find anatomic abnormalities potentially responsible for the present pain was 34% (205/597). When ordered by urologic providers, utility was 23%. Oncologists represented the highest positivity rate at 57%. Chronic pelvic pain is a multispecialty complaint that is difficult to treat. We were surprised to find the large number of both specialists and generalists invested in the management of pelvic pain. The increasing availability of MRI technology makes it a likely candidate to test for a clinically significant anatomic reason for pain. Though MRI is a test with minimal adverse effect and no increased risk

  5. Pelvic belt effects on sacroiliac joint ligaments: a computational approach to understand therapeutic effects of pelvic belts.

    Science.gov (United States)

    Sichting, Freddy; Rossol, Jerome; Soisson, Odette; Klima, Stefan; Milani, Thomas; Hammer, Niels

    2014-01-01

    The sacroiliac joint is a widely described source of low back pain. Therapeutic approaches to relieve pain include the application of pelvic belts. However, the effects of pelvic belts on sacroiliac joint ligaments as potential pain generators are mostly unknown. The aim of our study was to analyze the influence of pelvic belts on ligament load by means of a computer model. Experimental computer study using a finite element method. A computer model of the human pelvis was created, comprising bones, ligaments, and cartilage. Detailed geometries, material properties of ligaments, and in-vivo pressure distribution patterns of a pelvic belt were implemented. The effects of pelvic belts on ligament strain were computed in the double-leg stance. Pelvic belts increase sacroiliac joint motion around the sagittal axis but decrease motion around the transverse axis. With pelvic belt application, most of the strained sacroiliac joint ligaments were relieved, especially the sacrospinous, sacrotuberous, and the interosseous sacroiliac ligaments. Sacroiliac joint motion and ligament strains were minute. These results agree with validation data from other studies. Assigning homogenous and linear material properties and excluding muscle forces are clear simplifications of the complex reality. Pelvic belts alter sacroiliac joint motion and provide partial relief of ligament strain that is subjectively marked, although minimal in absolute terms. These findings confirm theories that besides being mechanical stabilizers, the sacroiliac joint ligaments are likely involved in neuromuscular feedback mechanisms. The results from our computer model help with unraveling the therapeutic mechanisms of pelvic belts.

  6. TomoTherapy MLC verification using exit detector data

    Energy Technology Data Exchange (ETDEWEB)

    Chen Quan; Westerly, David; Fang Zhenyu; Sheng, Ke; Chen Yu [TomoTherapy Inc., 1240 Deming Way, Madison, Wisconsin 53717 (United States); Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado 80045 (United States); Xinghua Cancer Hospital, Xinghua, Jiangsu 225700 (China); Department of Radiation Oncology, University of California-Los Angeles, Los Angeles, California 90095 (United States); TomoTherapy Inc., 1240 Deming Way, Madison, Wisconsin 53717 (United States)

    2012-01-15

    Purpose: Treatment delivery verification (DV) is important in the field of intensity modulated radiation therapy (IMRT). While IMRT and image guided radiation therapy (IGRT), allow us to create more conformal plans and enables the use of tighter margins, an erroneously executed plan can have detrimental effects on the treatment outcome. The purpose of this study is to develop a DV technique to verify TomoTherapy's multileaf collimator (MLC) using the onboard mega-voltage CT detectors. Methods: The proposed DV method uses temporal changes in the MVCT detector signal to predict actual leaf open times delivered on the treatment machine. Penumbra and scattered radiation effects may produce confounding results when determining leaf open times from the raw detector data. To reduce the impact of the effects, an iterative, Richardson-Lucy (R-L) deconvolution algorithm is applied. Optical sensors installed on each MLC leaf are used to verify the accuracy of the DV technique. The robustness of the DV technique is examined by introducing different attenuation materials in the beam. Additionally, the DV technique has been used to investigate several clinical plans which failed to pass delivery quality assurance (DQA) and was successful in identifying MLC timing discrepancies as the root cause. Results: The leaf open time extracted from the exit detector showed good agreement with the optical sensors under a variety of conditions. Detector-measured leaf open times agreed with optical sensor data to within 0.2 ms, and 99% of the results agreed within 8.5 ms. These results changed little when attenuation was added in the beam. For the clinical plans failing DQA, the dose calculated from reconstructed leaf open times played an instrumental role in discovering the root-cause of the problem. Throughout the retrospective study, it is found that the reconstructed dose always agrees with measured doses to within 1%. Conclusions: The exit detectors in the TomoTherapy treatment

  7. Angiogenic Blockade and Radiotherapy in Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Chi, Kwan-Hwa; Liao, Chao-Sheng; Chang, Chih-Chia; Ko, Hui-Ling; Tsang, Yuk-Wah; Yang, Kuo-Ching; Mehta, Minesh P.

    2010-01-01

    Purpose: We report our preliminary experience of combining sunitinib and helical tomotherapy in patients with advanced HCC. Methods and Materials: Records of patients with advanced hepatocellular carcinoma (HCC) treated with helical tomotherapy and sunitinib after radiation therapy (RT) from March 2007 to August 2008 were retrospectively reviewed. We report acute toxicities, radiologic response, serial α-fetoprotein (AFP) kinetics, and survival. Results: Of 23 evaluable patients, 60% had ≥2 hepatic lesions, extrahepatic disease was present in 5 (21.7%), and all received 2 tablets (25 mg) of sunitinib at least 1 week before, during, and 2 weeks after RT. Thirteen patients continued maintenance sunitinib after RT until disease progression. Hypofractionated RT with a median target dose of 52.5 Gy/15 fractions was delivered. An objective response was achieved in 74% of patients. The 1-year survival rate was 70%, with median survival of 16 months. Multivariate analysis showed that maintenance sunitinib was the most significant factor for survival. The time to progression was 10 months in the maintenance group compared with 4 months in the control group. Eighteen out of 21 patients with elevated AFP (85.7%) had ≥50% decline of AFP within 2 months after RT. There were three episodes of upper gastrointestinal bleeding and one episode of pancreatitis; 10 patients had ≥Grade 2 elevation of liver enzymes, and 15 had ≥Grade 2 thrombocytopenia. Conclusions: These preliminary results suggest that sunitinib and helical tomotherapy yield high Response Evaluation Criteria in Solid Tumors (RECIST) and AFP response rates in advanced HCC with an acceptable safety profile. Maintenance sunitinib after RT potentially prolongs survival. A randomized trial is warranted.

  8. Geometric validation of MV topograms for patient localization on TomoTherapy

    Science.gov (United States)

    Blanco Kiely, Janid P.; White, Benjamin M.; Low, Daniel A.; Qi, Sharon X.

    2016-01-01

    Our goal was to geometrically validate the use of mega-voltage orthogonal scout images (MV topograms) as a fast and low-dose alternative to mega-voltage computed tomography (MVCT) for daily patient localization on the TomoTherapy system. To achieve this, anthropomorphic head and pelvis phantoms were imaged on a 16-slice kilo-voltage computed tomography (kVCT) scanner to synthesize kilo-voltage digitally reconstructed topograms (kV-DRT) in the Tomotherapy detector geometry. MV topograms were generated for couch speeds of 1-4 cm s-1 in 1 cm s-1 increments with static gantry angles in the anterior-posterior and left-lateral directions. Phantoms were rigidly translated in the anterior-posterior (AP), superior-inferior (SI), and lateral (LAT) directions to simulate potential setup errors. Image quality improvement was demonstrated by estimating the noise level in the unenhanced and enhanced MV topograms using a principle component analysis-based noise level estimation algorithm. Average noise levels for the head phantom were reduced by 2.53 HU (AP) and 0.18 HU (LAT). The pelvis phantom exhibited average noise level reduction of 1.98 HU (AP) and 0.48 HU (LAT). Mattes Mutual Information rigid registration was used to register enhanced MV topograms with corresponding kV-DRT. Registration results were compared to the known rigid displacements, which assessed the MV topogram localization’s sensitivity to daily positioning errors. Reduced noise levels in the MV topograms enhanced the registration results so that registration errors were  pairs in the context bony-anatomy based procedures such as total marrow irradiation, total body irradiation, and cranial spinal irradiation.

  9. Chronic pelvic floor dysfunction.

    Science.gov (United States)

    Hartmann, Dee; Sarton, Julie

    2014-10-01

    The successful treatment of women with vestibulodynia and its associated chronic pelvic floor dysfunctions requires interventions that address a broad field of possible pain contributors. Pelvic floor muscle hypertonicity was implicated in the mid-1990s as a trigger of major chronic vulvar pain. Painful bladder syndrome, irritable bowel syndrome, fibromyalgia, and temporomandibular jaw disorder are known common comorbidities that can cause a host of associated muscular, visceral, bony, and fascial dysfunctions. It appears that normalizing all of those disorders plays a pivotal role in reducing complaints of chronic vulvar pain and sexual dysfunction. Though the studies have yet to prove a specific protocol, physical therapists trained in pelvic dysfunction are reporting success with restoring tissue normalcy and reducing vulvar and sexual pain. A review of pelvic anatomy and common findings are presented along with suggested physical therapy management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. SU-E-T-372: Dosimetric Comparison of Craniospinal Irradiation Using Different Tomotherapy Techniques

    International Nuclear Information System (INIS)

    Zhang, X; Penagaricano, J; Han, E; Liang, X; Morrill, S; Hardee, M; Gupta, S; Vaneerat, R

    2014-01-01

    Purpose: TomoHDA can treat with fixed jaws, dynamic jaws, and fixed gantry using either 3DCRT or IMRT. This study compares PTV coverage, OAR sparing, and beam-on-time (BOT) among these techniques for craniospinal irradiation (CSI). Methods: This study includes ten CSI patients treated to 23.4 Gy/13 fractions with Hi-Art 3.0 unit (HT-IMRT fixed 5 cm jaw). New plans were regenerated with 5 cm jaw for TomoHDA Hi-Art 5.0 using dynamic jaw (HD-IMRT), TomoDirect-IMRT (TD-IMRT), and Helical Tomotherapy 3DCRT (HT-3DCRT using 5 cm and 2.5 cm jaws with various pitches). Studied parameters include PTV mean dose, D95 (dose covering 95% of PTV), Paddick's conformity index (CI) and homogeneity index (HI – standard deviation of PTV dose/average PTV dose), BOT, and average OAR doses. Results: PTV coverage from these techniques were comparable (p>0.05). The main differences were in OAR sparing; HDIMRT reduced more OAR doses for lenses, bladder and rectum compared to HT-IMRT. For the sparing of visceral organs: liver, lung, heart, and kidneys, the three IMRT techniques gave comparable results. HD-IMRT gave best heart sparing; HT-IMRT best kidney sparing. Liver and lung doses were best reduced by TD-IMRT. All three IMRT techniques gave comparable BOT. OARs sparing was achieved for jaw size of 2.5 cm. HI was also improved but with doubling of BOT. Increasing the pitch number from 0.2 to 0.43 produced no significant improvement in OAR sparing but CI and HI did improve. Conclusion: HT-3DCRT, HT-IMRT, HD-IMRT or TD-IMRT techniques give comparable PTV coverage but the three IMRT plans better spared OARs compared with 3DCRT plans. Dynamic jaw plan is superior to fixed jaw plan to spare more OAR doses at field edge. TD-IMRT cannot reduce BOT for CSI patient but for sparing certain OAR, TD-IMRT may be used to avoid the beam going through the structures of interest

  11. Dosimetric comparison of photon and proton treatment techniques for chondrosarcoma of thoracic spine

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, Poonam, E-mail: yadav@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, WI (United States); University of Wisconsin Riverview Cancer Center, Wisconsin Rapids, WI (United States); Paliwal, Bhudatt R. [Department of Human Oncology, University of Wisconsin, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, WI (United States); Kozak, Kevin [Department of Human Oncology, University of Wisconsin, Madison, WI (United States)

    2013-10-01

    Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy. Retrospectively, the tomotherapy plan was compared with intensity-modulated radiation therapy, dynamic arc photon therapy, and proton therapy. Two primary comparisons were made: (1) comparison of normal tissue sparing with comparable target volume coverage (plan-1), and (2) comparison of target volume coverage with a constrained maximum dose to the cord center (plan-2). With constrained target volume coverage, proton plans were found to yield lower mean doses for all organs at risk (spinal cord, esophagus, heart, and both lungs). Tomotherapy planning resulted in the lowest mean dose to all organs at risk amongst photon-based methods. For cord dose constrained plans, the static-field intensity-modulated radiation therapy and dynamic arc plans resulted target underdosing in 20% and 12% of planning target volume2 volumes, respectively, whereas both proton and tomotherapy plans provided clinically acceptable target volume coverage with no portion of planning target volume2 receiving less than 90% of the prescribed dose. Tomotherapy plans are comparable to proton plans and produce superior results compared with other photon modalities. This feasibility study suggests that tomotherapy is an attractive alternative to proton radiotherapy for delivering high doses to lesions in the thoracic spine.

  12. Dosimetric comparison of photon and proton treatment techniques for chondrosarcoma of thoracic spine

    International Nuclear Information System (INIS)

    Yadav, Poonam; Paliwal, Bhudatt R.; Kozak, Kevin

    2013-01-01

    Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy. Retrospectively, the tomotherapy plan was compared with intensity-modulated radiation therapy, dynamic arc photon therapy, and proton therapy. Two primary comparisons were made: (1) comparison of normal tissue sparing with comparable target volume coverage (plan-1), and (2) comparison of target volume coverage with a constrained maximum dose to the cord center (plan-2). With constrained target volume coverage, proton plans were found to yield lower mean doses for all organs at risk (spinal cord, esophagus, heart, and both lungs). Tomotherapy planning resulted in the lowest mean dose to all organs at risk amongst photon-based methods. For cord dose constrained plans, the static-field intensity-modulated radiation therapy and dynamic arc plans resulted target underdosing in 20% and 12% of planning target volume2 volumes, respectively, whereas both proton and tomotherapy plans provided clinically acceptable target volume coverage with no portion of planning target volume2 receiving less than 90% of the prescribed dose. Tomotherapy plans are comparable to proton plans and produce superior results compared with other photon modalities. This feasibility study suggests that tomotherapy is an attractive alternative to proton radiotherapy for delivering high doses to lesions in the thoracic spine

  13. Radiographic cup anteversion measurement corrected from pelvic tilt.

    Science.gov (United States)

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Recent Advances in Understanding Pelvic-Floor Tissue of Women With and Without Pelvic Organ Prolapse: Considerations for Physical Therapists.

    Science.gov (United States)

    Saunders, Kimberly

    2017-04-01

    Pelvic organ prolapse is a fairly common condition that imposes significant symptoms, diminished quality of life, social burden, financial expense, and surgical risk on women. As evidence supporting the benefit of pelvic-floor muscle training in nonsurgical management of pelvic organ prolapse grows, physical therapists are becoming a provider of choice interacting with women affected by pelvic organ prolapse. This perspective article will review recent research on tissue characteristics of 3 key components of pelvic organ support: skeletal muscle, ligament, and vaginal wall. This information will be summarized as implications for physical therapists. An improved understanding of pelvic-floor tissue in women with and without pelvic organ prolapse will provide a more comprehensive appreciation of the interaction of multiple systems in the disorder. © 2017 American Physical Therapy Association.

  15. Lifestyle advice with or without pelvic floor muscle training for pelvic organ prolapse

    DEFF Research Database (Denmark)

    Due, Ulla; Brostrøm, Søren; Lose, Gunnar

    2016-01-01

    INTRODUCTION AND HYPOTHESIS: We evaluated the effect of adding pelvic floor muscle training (PFMT) to a structured lifestyle advice program. METHODS: This was a single-blinded randomized trial of women with symptomatic pelvic organ prolapse (POP) stage ≥ II. Participants were randomized...

  16. Minimally invasive anterior pelvic internal fixation: An anatomic study comparing Pelvic Bridge to INFIX.

    Science.gov (United States)

    Reichel, Lee M; MacCormick, Lauren M; Dugarte, Anthony J; Rizkala, Amir R; Graves, Sara C; Cole, Peter A

    2018-02-01

    Anterior external fixation for pelvic ring fractures has shown to effectively improve stability and reduce mortality. However, these fixators can be associated with substantial morbidity such as pin tract infection, premature loss of fixation, and decreased quality of life in patients. Recently, two new methods of subcutaneous anterior pelvic internal fixation have been developed; the INFIX and the Pelvic Bridge. These methods have the purported advantages of lower wound complications, less surgical site pain, and improved quality of life. We sought to investigate the measured distances to critical anatomic structures, as well as the qualitative and topographic differences notable during implantation of both devices in the same cadaveric specimen. The Pelvic Bridge and INFIX were implanted in eleven fresh cadavers. Distances were then measured to: the superficial inguinal ring, round ligament, spermatic cord, lateral femoral cutaneous nerve (LFCN), femoral nerve, femoral artery, and femoral vein. Observations regarding implantation and topography were also recorded. The INFIX had greater measured distances from all structures except for the LFCN, in which its proximity placed this structure at risk. Neither device appears to put other critical structures at risk in the supine position. Significant implantation and topographic differences exist between the devices. The INFIX application lacked "safety margins" concerning the LFCN in 10/11 (90.9%) specimens, while Pelvic Bridge placement lacked "safety margins" with regard to the right superficial ring (1/11, 9%) and the right spermatic cord (1/11, 9%). Both the Pelvic Bridge and INFIX lie at safe distances from most critical pelvic structures in the supine position, though INFIX application places the LFCN at risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Pelvic floor and sexual male dysfunction

    Directory of Open Access Journals (Sweden)

    Antonella Pischedda

    2013-04-01

    Full Text Available The pelvic floor is a complex multifunctional structure that corresponds to the genito- urinary-anal area and consists of muscle and connective tissue. It supports the urinary, fecal, sexual and reproductive functions and pelvic statics. The symptoms caused by pelvic floor dysfunction often affect the quality of life of those who are afflicted, worsening significantly more aspects of daily life. In fact, in addition to providing support to the pelvic organs, the deep floor muscles support urinary continence and intestinal emptying whereas the superficial floor muscles are involved in the mechanism of erection and ejaculation. So, conditions of muscle hypotonia or hypertonicity may affect the efficiency of the pelvic floor, altering both the functionality of the deep and superficial floor muscles. In this evolution of knowledge it is possible imagine how the rehabilitation techniques of pelvic floor muscles, if altered and able to support a voiding or evacuative or sexual dysfunction, may have a role in improving the health and the quality of life.

  18. Mode of delivery and Pelvic floor disorder

    International Nuclear Information System (INIS)

    Noor, R.; Neelam, H.; Bashir, M.S.

    2017-01-01

    Objective: To compare pelvic floor dysfunction in non pregnant women who had delivered vaginally versus those with cesarean delivery. Methodology: The prevalence of pelvic floor disorders among non pregnant women was assesses by using a standardized tool pelvic floor distress inventory short form (PFDI-20). Data was collected from Jinnah Hospital Lahore, Pakistan. Results: Total numbers of participants were 278. 47.12% subjects had moderate, 36.69% miner and 16.19% had severe pelvic floor dysfunction. The symptoms of pelvic organ prolapse were more prevalent (mean value is 59.1876) than Urinary Distress (mean value is 40.5426), while the Colorectal-Anal Distress (mean value is 35.9150) were least prevalent. Conclusion: Pelvic floor disorders are very common among females and are strongly associated with mode of delivery. Although spontaneous vaginal birth was extensively associated with pelvic floor disorders the instrumental delivery affects most. (author)

  19. Pyrolysis of Helical Coordination Polymers for Metal-Sulfide-Based Helices with Broadband Chiroptical Activity.

    Science.gov (United States)

    Hirai, Kenji; Yeom, Bongjun; Sada, Kazuki

    2017-06-27

    Fabrication of chiroptical materials with broadband response in the visible light region is vital to fully realize their potential applications. One way to achieve broadband chiroptical activity is to fabricate chiral nanostructures from materials that exhibit broadband absorption in the visible light region. However, the compounds used for chiroptical materials have predominantly been limited to materials with narrowband spectral response. Here, we synthesize Ag 2 S-based nanohelices derived from helical coordination polymers. The right- and left-handed coordination helices used as precursors are prepared from l- and d-glutathione with Ag + and a small amount of Cu 2+ . The pyrolysis of the coordination helices yields right- and left-handed helices of Cu 0.12 Ag 1.94 S/C, which exhibit chiroptical activity spanning the entire visible light region. Finite element method simulations substantiate that the broadband chiroptical activity is attributed to synergistic broadband light absorption and light scattering. Furthermore, another series of Cu 0.10 Ag 1.90 S/C nanohelices are synthesized by choosing the l- or d-Glu-Cys as starting materials. The pitch length of nanohelicies is controlled by changing the peptides, which alters their chiroptical properties. The pyrolysis of coordination helices enables one to fabricate helical Ag 2 S-based materials that enable broadband chiroptical activity but have not been explored owing to the lack of synthetic routes.

  20. Biomechanics of the pelvic floor musculature

    NARCIS (Netherlands)

    Janda, S.

    2006-01-01

    The present thesis was motivated by two main goals. The first research goal of the thesis was to understand the complex biomechanical behaviour of the pelvic floor muscles. The second goal was to study the mechanism of the pelvic organ prolapse (genital prolapse). The pelvic floor in humans is a

  1. Analysis of daily quality assurance tests for tomotherapy and two Varian linear accelerators - three months review

    International Nuclear Information System (INIS)

    Kushwaha, Pratishtha; Jaiswal, Deeksha; Dheera, A.; Upreti, Udita; Chaudhari, Suresh; Kinhikar, Rajesh; Deshpande, Deepak; Shrivastava, Shyam

    2016-01-01

    Daily quality assurance (QA) for high precision radiotherapy equipments is very important to maintain the mechanical and dosimetric accuracy for patient treatments. Gross deviations in these parameters may have an adverse impact on the delivery of the treatments to patients. We report the results of daily QA tests performed over a period of three months for two Varian linear accelerators and a Tomotherapy machine

  2. Employing helicity amplitudes for resummation

    International Nuclear Information System (INIS)

    Moult, Ian; Stewart, Iain W.; Tackmann, Frank J.; Waalewijn, Wouter J.; Amsterdam Univ.

    2015-08-01

    Many state-of-the-art QCD calculations for multileg processes use helicity amplitudes as their fundamental ingredients. We construct a simple and easy-to-use helicity operator basis in soft-collinear effective theory (SCET), for which the hard Wilson coefficients from matching QCD onto SCET are directly given in terms of color-ordered helicity amplitudes. Using this basis allows one to seamlessly combine fixed-order helicity amplitudes at any order they are known with a resummation of higher-order logarithmic corrections. In particular, the virtual loop amplitudes can be employed in factorization theorems to make predictions for exclusive jet cross sections without the use of numerical subtraction schemes to handle real-virtual infrared cancellations. We also discuss matching onto SCET in renormalization schemes with helicities in 4- and d-dimensions. To demonstrate that our helicity operator basis is easy to use, we provide an explicit construction of the operator basis, as well as results for the hard matching coefficients, for pp → H+0,1,2 jets, pp → W/Z/γ+0,1,2 jets, and pp → 2,3 jets. These operator bases are completely crossing symmetric, so the results can easily be applied to processes with e + e - and e - p collisions.

  3. Postoperative low-pelvic irradiation for stage I-IIA cervical cancer patients with risk factors other than pelvic lymph node metastasis

    International Nuclear Information System (INIS)

    Hong, J.-H.; Tsai, C.-S.; Lai, C.-H.; Chang, T.-C.; Wang, C.-C.; Lee, Steve P.; Tseng, C.-J.; Hsueh, Swei

    2002-01-01

    Purpose: To retrospectively investigate whether postoperative low-pelvic radiotherapy (RT) is an appropriate treatment for node-negative, high-risk Stage I-IIA cervical cancer patients. Methods and Materials: A total of 228 Stage I-IIA cervical cancer patients treated by radical surgery and postoperative RT were included in this study. All patients had histopathologically negative pelvic node metastasis, but at least one of the following risk factors: parametrial involvement, positive or close resection margins, invasion depth two-thirds or greater cervical stromal thickness. Seventy-nine patients (35%) received 30-50 Gy (median 44) to whole pelvis and a boost dose to the low pelvis (whole-pelvic RT group); the other 149 patients (65%) received low-pelvic RT only (low-pelvic RT group). For both groups, the total external RT dose to the low pelvis ranged from 40 to 60 Gy (median 50). The potential factors associated with survival, small bowel (gastrointestinal) complications, and leg lymphedema were analyzed, and patients who had a relapse in the upper pelvis were identified. Results: The 5-year overall and disease-specific survival rate was 84% and 86%, respectively. After multivariate analysis, only bulky tumor (≥4 cm) and non-squamous cell carcinoma were significantly associated with survival. Parametrial involvement, lymph-vascular invasion, ≤50.4 Gy to the low pelvis, positive or close margins, and low-pelvic RT alone did not significantly affect survival. Grade I-V small bowel complications occurred in 33 patients (15%). Whole pelvic RT and >50.4 Gy to the low pelvis, but not old age and treatment technique (AP-PA vs. box), were significantly associated with gastrointestinal complications. Three patients (2%) in the low-pelvic RT group and 6 patients (8%) in the whole-pelvic RT group were found to have Grade III or higher small bowel complications (p=0.023). Thirty-one percent of patients developed lymphedema of the leg. A dose to the low pelvis >50.4 Gy

  4. The screening pelvic radiograph in pediatric trauma

    International Nuclear Information System (INIS)

    Rees, M.J.; Aickin, R.; Kolbe, A.; Teele, R.L.

    2001-01-01

    Background. Pelvic radiographs are routinely obtained in adult trauma to optimise early management. In adults, pelvic fractures are associated with high early transfusion requirement, high injury severity scores and an increased incidence of other abdominal and thoracic injuries. It is unclear whether this holds true in children. Objective. To determine whether the screening pelvic radiograph is necessary in paediatric trauma. Materials and methods. The notes of all patients who presented after trauma to the Starship Children's Hospital and were triaged to the resuscitation room during 1997 were reviewed. Results of initial radiography were obtained and correlated with later imaging. Results. Our review of 444 injured children seen over a period of 1 year revealed that of 347 children who had screening pelvic radiographs, only 1 had a pelvic fracture. The fracture in this child was clinically apparent and required no specific treatment. Conclusions. The presence of a pelvic fracture is rare in injured children. By omitting screening pelvic radiographs there are potential benefits, including reduced radiation exposure to children and cost savings. Uninterpretable or abnormal clinical examination or haematuria requires further investigation, but routine screening for pelvic fracture is unnecessary. (orig.)

  5. Recognition and Management of Nonrelaxing Pelvic Floor Dysfunction

    OpenAIRE

    Faubion, Stephanie S.; Shuster, Lynne T.; Bharucha, Adil E.

    2012-01-01

    Nonrelaxing pelvic floor dysfunction is not widely recognized. Unlike in pelvic floor disorders caused by relaxed muscles (eg, pelvic organ prolapse or urinary incontinence, both of which often are identified readily), women affected by nonrelaxing pelvic floor dysfunction may present with a broad range of nonspecific symptoms. These may include pain and problems with defecation, urination, and sexual function, which require relaxation and coordination of pelvic floor muscles and urinary and ...

  6. MR imaging in female pelvic organs prolapse

    International Nuclear Information System (INIS)

    Capiel, Carlos A. h; Bouzas, Carlos A.

    2003-01-01

    Pelvic floor weakness and consequent organ prolapse may result in a variety of symptoms, including pain, urinary or fecal incontinence and constipation. Diagnosis is made primary on the basis of findings at physical pelvic examination. Imaging is useful in patients in whom findings at physical examination are equivocal. Different imaging techniques (fluoroscopy, ultrasonography), can be useful in evaluating pelvic organs prolapse. MR imaging is a new noninvasive technique that provides a multiplanar global evaluation of the pelvic contents and demonstrates pelvic organs prolapse. Reference points are the pubococcygeal line and puborectalis muscle sling. This pictorial assay illustrates different grades of cystourethrocele, recto-sigmoidocele and hysteroptosis (uterine prolapse) on MR imaging. (author)

  7. Extraperitoneal pelvic leiomyosarcoma

    International Nuclear Information System (INIS)

    Santamarina, Mario G.; Baltazar, Alberto D.; Arce, Patricia; Dettano, Veronica; Lopez, Jessica

    2003-01-01

    Extraperitoneal pelvic leiomyosarcoma is a very uncommon neoplasic process. It is a highly aggressive tumor with unfavorable prognosis. Clinical findings are nonspecific; diagnosis is generally made in an advanced stage of the disease. We present a case of a 34 years old female patient with pelvic leiomyosarcoma located at the recto vaginal septum who referred vulvar tumor and disability of the left lower limb. This case report describes the results obtained by ultrasound, Computed Tomography, Magnetic Resonance Imaging and pathology. (author)

  8. Magnetic helicity balance in the Sustained Spheromak Plasma Experiment

    International Nuclear Information System (INIS)

    Stallard, B.W.; Hooper, E.B.; Woodruff, S.; Bulmer, R.H.; Hill, D.N.; McLean, H.S.; Wood, R.D.

    2003-01-01

    The magnetic helicity balance between the helicity input injected by a magnetized coaxial gun, the rate-of-change in plasma helicity content, and helicity dissipation in electrode sheaths and Ohmic losses have been examined in the Sustained Spheromak Plasma Experiment (SSPX) [E. B. Hooper, L. D. Pearlstein, and R. H. Bulmer, Nucl. Fusion 39, 863 (1999)]. Helicity is treated as a flux function in the mean-field approximation, allowing separation of helicity drive and losses between closed and open field volumes. For nearly sustained spheromak plasmas with low fluctuations, helicity balance analysis implies a decreasing transport of helicity from the gun input into the spheromak core at higher spheromak electron temperature. Long pulse discharges with continuously increasing helicity and larger fluctuations show higher helicity coupling from the edge to the spheromak core. The magnitude of the sheath voltage drop, inferred from cathode heating and a current threshold dependence of the gun voltage, shows that sheath losses are important and reduce the helicity injection efficiency in SSPX

  9. Analysis of Daily Setup Variation With Tomotherapy Megavoltage Computed Tomography

    International Nuclear Information System (INIS)

    Zhou Jining; Uhl, Barry; Dewit, Kelly; Young, Mark; Taylor, Brian; Fei Dingyu; Lo, Y-C

    2010-01-01

    The purpose of this study was to evaluate different setup uncertainties for various anatomic sites with TomoTherapy (registered) pretreatment megavoltage computed tomography (MVCT) and to provide optimal margin guidelines for these anatomic sites. Ninety-two patients with tumors in head and neck (HN), brain, lung, abdominal, or prostate regions were included in the study. MVCT was used to verify patient position and tumor target localization before each treatment. With the anatomy registration tool, MVCT provided real-time tumor shift coordinates relative to the positions where the simulation CT was performed. Thermoplastic facemasks were used for HN and brain treatments. Vac-Lok TM cushions were used to immobilize the lower extremities up to the thighs for prostate patients. No respiration suppression was administered for lung and abdomen patients. The interfractional setup variations were recorded and corrected before treatment. The mean interfractional setup error was the smallest for HN among the 5 sites analyzed. The average 3D displacement in lateral, longitudinal, and vertical directions for the 5 sites ranged from 2.2-7.7 mm for HN and lung, respectively. The largest movement in the lung was 2.0 cm in the longitudinal direction, with a mean error of 6.0 mm and standard deviation of 4.8 mm. The mean interfractional rotation variation was small and ranged from 0.2-0.5 deg., with the standard deviation ranging from 0.7-0.9 deg. Internal organ displacement was also investigated with a posttreatment MVCT scan for HN, lung, abdomen, and prostate patients. The maximum 3D intrafractional displacement across all sites was less than 4.5 mm. The interfractional systematic errors and random errors were analyzed and the suggested margins for HN, brain, prostate, abdomen, and lung in the lateral, longitudinal, and vertical directions were between 4.2 and 8.2 mm, 5.0 mm and 12.0 mm, and 1.5 mm and 6.8 mm, respectively. We suggest that TomoTherapy (registered) pretreatment

  10. Analysis of daily setup variation with tomotherapy megavoltage computed tomography.

    Science.gov (United States)

    Zhou, Jining; Uhl, Barry; Dewit, Kelly; Young, Mark; Taylor, Brian; Fei, Ding-Yu; Lo, Yeh-Chi

    2010-01-01

    The purpose of this study was to evaluate different setup uncertainties for various anatomic sites with TomoTherapy pretreatment megavoltage computed tomography (MVCT) and to provide optimal margin guidelines for these anatomic sites. Ninety-two patients with tumors in head and neck (HN), brain, lung, abdominal, or prostate regions were included in the study. MVCT was used to verify patient position and tumor target localization before each treatment. With the anatomy registration tool, MVCT provided real-time tumor shift coordinates relative to the positions where the simulation CT was performed. Thermoplastic facemasks were used for HN and brain treatments. Vac-Lok cushions were used to immobilize the lower extremities up to the thighs for prostate patients. No respiration suppression was administered for lung and abdomen patients. The interfractional setup variations were recorded and corrected before treatment. The mean interfractional setup error was the smallest for HN among the 5 sites analyzed. The average 3D displacement in lateral, longitudinal, and vertical directions for the 5 sites ranged from 2.2-7.7 mm for HN and lung, respectively. The largest movement in the lung was 2.0 cm in the longitudinal direction, with a mean error of 6.0 mm and standard deviation of 4.8 mm. The mean interfractional rotation variation was small and ranged from 0.2-0.5 degrees, with the standard deviation ranging from 0.7-0.9 degrees. Internal organ displacement was also investigated with a posttreatment MVCT scan for HN, lung, abdomen, and prostate patients. The maximum 3D intrafractional displacement across all sites was less than 4.5 mm. The interfractional systematic errors and random errors were analyzed and the suggested margins for HN, brain, prostate, abdomen, and lung in the lateral, longitudinal, and vertical directions were between 4.2 and 8.2 mm, 5.0 mm and 12.0 mm, and 1.5 mm and 6.8 mm, respectively. We suggest that TomoTherapy pretreatment MVCT can be used to

  11. Morbidity and outcome of pelvic exenteration in locally advanced pelvic malignancies.

    Science.gov (United States)

    Ramamurthy, Rajaraman; Duraipandian, Amudhan

    2012-09-01

    Pelvic exenteration is a technically demanding surgical procedure performed for locally advanced cancers in the pelvis. Aim of the present study was to analyze morbidity, failure pattern and survival after pelvic exenteration during a period of 15 years in a dedicated cancer centre in South India. Retrospective analysis of case records of 50 patients who underwent pelvic exenteration from 1996 to 2011 in the Department of Surgical Oncology, Government Royapettah Hospital Chennai. Forty-six patients were females and 4 were males with a mean age of 48.3 years (range 21-72). Twenty six patients had cervical cancer,14 had rectal cancer, 3 had bladder cancer,2 had endometrial cancer, 2 had vaginal cancer, 1 had uterine sarcoma, 1 had anal cancer and 1 had ovarian cancer. The postoperative morbidity was 50%. 7 patients (14%) developed recurrence of which 5 had local and 2 had distant recurrence. The estimated 5 year overall survival for all patients in our series was 53.5% and for the patients with Ca rectum and Ca cervix was 60.6% and 40.1% respectively. Adjacent organ invasion had a significant impact over survival. Pelvic exenteration provides a curative form of treatment for carefully selected locally advanced cancer in the pelvis and it can be done safely with acceptable complications in centers experienced in multivisceral resections.

  12. Reconstruction of Complex Post-Traumatic Perineal/Pelvic Defects ...

    African Journals Online (AJOL)

    of the pelvic diaphragm). A composite pedicled. ALT flap was considered adequate for the initial reconstruction and stabilization, with the option of using a free fibular flap later, should the pelvic ring remain unstable. The fascia was used to complete the pelvic ring. It also provided anterior support to the pelvic diaphragm.

  13. Diffusion in a tokamak with helical magnetic cells

    International Nuclear Information System (INIS)

    Wakatani, Masahiro

    1975-05-01

    In a tokamak with helical magnetic cells produced by a resonant helical magnetic field, diffusion in the collisional regime is studied. The diffusion coefficient is greatly enhanced near the resonant surface even for a weak helical magnetic field. A theoretical model for disruptive instabilities based on the enhanced transport due to helical magnetic cells is discussed. This may explain experiments of the tokamak with resonant helical fields qualitatively. (author)

  14. Pelvic floor dysfunction, and effects of pregnancy and mode of delivery on pelvic floor

    Directory of Open Access Journals (Sweden)

    Murat Bozkurt

    2014-12-01

    Full Text Available Pelvic floor dysfunction (PFD, although seems to be simple, is a complex process that develops secondary to multifactorial factors. The incidence of PFD is increasing with increasing life expectancy. PFD is a term that refers to a broad range of clinical scenarios, including lower urinary tract excretory and defecation disorders, such as urinary and anal incontinence, overactive bladder, and pelvic organ prolapse, as well as sexual disorders. It is a financial burden on the health care system and disrupts women's quality of life. Strategies applied to decrease PFD are focused on the course of pregnancy, mode and management of delivery, and pelvic exercise methods. Many studies in the literature define traumatic birth, usage of forceps, length of the second stage of delivery, and sphincter damage as modifiable risk factors for PFD. Maternal age, fetal position, and fetal head circumference are nonmodifiable risk factors. Although numerous studies show that vaginal delivery affects pelvic floor structures and their functions in a negative way, there is not enough scientific evidence to recommend elective cesarean delivery in order to prevent development of PFD. PFD is a heterogeneous pathological condition, and the effects of pregnancy, vaginal delivery, cesarean delivery, and possible risk factors of PFD may be different from each other. Observational studies have identified certain obstetrical exposures as risk factors for pelvic floor disorders. These factors often coexist; therefore, the isolated effects of these variables on the pelvic floor are difficult to study. The routine use of episiotomy for many years in order to prevent PFD is not recommended anymore; episiotomy should be used in selected cases, and the mediolateral procedures should be used if needed.

  15. Dynamics of zonal flows in helical systems.

    Science.gov (United States)

    Sugama, H; Watanabe, T-H

    2005-03-25

    A theory for describing collisionless long-time behavior of zonal flows in helical systems is presented and its validity is verified by gyrokinetic-Vlasov simulation. It is shown that, under the influence of particles trapped in helical ripples, the response of zonal flows to a given source becomes weaker for lower radial wave numbers and deeper helical ripples while a high-level zonal-flow response, which is not affected by helical-ripple-trapped particles, can be maintained for a longer time by reducing their bounce-averaged radial drift velocity. This implies a possibility that helical configurations optimized for reducing neoclassical ripple transport can simultaneously enhance zonal flows which lower anomalous transport.

  16. Serial tomotherapy vs. MLC-IMRT (Multileaf Collimator Intensity Modulated Radiotherapy) for simultaneous boost treatment large intracerebral lesions

    International Nuclear Information System (INIS)

    Wolff, Dirk; Lohr, Frank; Mai, Sabine; Polednik, Martin; Wenz, Frederik; Dobler, Barbara

    2009-01-01

    Introduction: Recent data suggest that a radiosurgery boost treatment for up to three brain metastases in addition to whole brain radiotherapy (WBRT) is beneficial. Sequential treatment of multiple metastatic lesions is time-consuming and optimal normal tissue sparing is not trivial for larger metastases when separate plans are created and are only superimposed afterwards. Sequential Tomotherapy with noncoplanar arcs and Multi-field IMRT may streamline the process and enable easy simultaneous treatment. We compared plans for 2-3 intracerebral targets calculated with Intensity Modulated Radiotherapy (IMRT) based on treatment with MLC or sequential Tomotherapy using the Peacock-System. Treatment time was not to exceed 90 min on a linac with standart dose rate. MIMiC plans without treatment-time restrictions were created as a benchmark. Materials and methods: Calculations are based on a Siemens KD2 linac with a dose rate of 200 MU/min. Step-and-Shoot IMRT is performed with a standard MLC (2 x 29 leaves, 1 cm), serial Tomotherapy with the Multivane-Collimator MIMiC (NOMOS Inc. USA). Treatment plans are created with Corvus 5.0. To create plans with good conformity we chose a noncoplanar beam- and arc geometry for each approach (IMRT 4-, MIMiC 5-couch angles). The benchmark MIMiC plans with maximally steep dose gradients had 9 couch angles. For plan comparison reasons, 10Gy were prescribed to 90% of the PTV. Steepness of dose gradients, homogeneity and conformity were assessed by the following parameters: Volume encompassed by certain isodoses outside the target as well as homogeneity and conformity as indicated by Homogeneity- and Conformity-Index. Results: Plans without treatment-time restrictions had slightest dose to organ at risk (OAR), normal tissue and least Conformity-index. MIMiC- and MLC-IMRT based plans can be treated within the intended period of 90 min, all plans met the required dose. MLC based plans resulted in higher dose to organs at risk (OAR) and dose

  17. Parameterization and measurements of helical magnetic fields

    International Nuclear Information System (INIS)

    Fischer, W.; Okamura, M.

    1997-01-01

    Magnetic fields with helical symmetry can be parameterized using multipole coefficients (a n , b n ). We present a parameterization that gives the familiar multipole coefficients (a n , b n ) for straight magnets when the helical wavelength tends to infinity. To measure helical fields all methods used for straight magnets can be employed. We show how to convert the results of those measurements to obtain the desired helical multipole coefficients (a n , b n )

  18. Dynamics and deformability of α-, 310- and π-helices

    Directory of Open Access Journals (Sweden)

    Narwani Tarun Jairaj

    2018-01-01

    Full Text Available Protein structures are often represented as seen in crystals as (i rigid macromolecules (ii with helices, sheets and coils. However, both definitions are partial because (i proteins are highly dynamic macromolecules and (ii the description of protein structures could be more precise. With regard to these two points, we analyzed and quantified the stability of helices by considering α-helices as well as 310- and π-helices. Molecular dynamic (MD simulations were performed on a large set of 169 representative protein domains. The local protein conformations were followed during each simulation and analyzed. The classical flexibility index (B-factor was confronted with the MD root mean square flexibility (RMSF index. Helical regions were classified according to their level of helicity from high to none. For the first time, a precise quantification showed the percentage of rigid and flexible helices that underlie unexpected behaviors. Only 76.4% of the residues associated with α-helices retain the conformation, while this tendency drops to 40.5% for 310-helices and is never observed for π-helices. α-helix residues that do not remain as an α-helix have a higher tendency to assume β-turn conformations than 310- or π-helices. The 310-helices that switch to the α-helix conformation have a higher B-factor and RMSF values than the average 310-helix but are associated with a lower accessibility. Rare π-helices assume a β-turn, bend and coil conformations, but not α- or 310-helices. The view on π-helices drastically changes with the new DSSP (Dictionary of Secondary Structure of Proteins assignment approach, leading to behavior similar to 310-helices, thus underlining the importance of secondary structure assignment methods.

  19. Functional anatomy of pelvic floor

    Directory of Open Access Journals (Sweden)

    Salvatore Rocca Rossetti

    2016-03-01

    Full Text Available Generally, descriptions of the pelvic floor are discordant, since its complex structures and the complexity of pathological disorders of such structures; commonly the descriptions are sectorial, concerning muscles, fascial developments, ligaments and so on. On the contrary to understand completely nature and function of the pelvic floor it is necessary to study it in the most unitary view and in the most global aspect, considering embriology, philogenesy, anthropologic development and its multiple activities others than urological, gynaecological and intestinal ones. Recent acquirements succeeded in clarifying many aspects of pelvic floor activity, whose musculature has been investigated through electromyography, sonography, magnetic resonance, histology, histochemistry, molecular research. Utilizing recent research concerning not only urinary and gynecologic aspects but also those regarding statics and dynamics of pelvis and its floor, it is now possible to study this important body part as a unit; that means to consider it in the whole body economy to which maintaining upright position, walking and behavior or physical conduct do not share less than urinary, genital, and intestinal functions. It is today possible to consider the pelvic floor as a musclefascial unit with synergic and antagonistic activity of muscular bundles, among them more or less interlaced, with multiple functions and not only the function of pelvic cup closure.

  20. Pelvic belt effects on pelvic morphometry, muscle activity and body balance in patients with sacroiliac joint dysfunction.

    Directory of Open Access Journals (Sweden)

    Odette Soisson

    Full Text Available The sacroiliac joint (SIJ is frequently involved in low back and pelvic girdle pain. However, morphometrical and functional characteristics related to SIJ pain are poorly defined. Pelvic belts represent one treatment option, but evidence still lacks as to their pain-reducing effects and the mechanisms involved. Addressing these two issues, this case-controlled study compares morphometric, functional and clinical data in SIJ patients and healthy controls and evaluates the effects of short-term pelvic belt application.Morphometric and functional data pertaining to pelvic belt effects were compared in 17 SIJ patients and 17 controls. Lumbar spine and pelvis morphometries were obtained from 3T magnetic resonance imaging. Functional electromyography data of pelvis and leg muscles and center of pressure excursions were measured in one-leg stance. The numerical rating scale was used to evaluate immediate pain-reducing effects.Pelvic morphometry was largely unaltered in SIJ patients and also by pelvic belt application. The angle of lumbar lateral flexion was significantly larger in SIJ patients without belt application. Muscle activity and center of pressure were unaffected by SIJ pain or by belt application in one-leg stance. Nine of 17 patients reported decreased pain intensities under moderate belt application, four reported no change and four reported increased pain intensity. For the entire population investigated here, this qualitative description was not confirmed on a statistical significant level.Minute changes were observed in the alignment of the lumbar spine in the frontal plane in SIJ patients. The potential pain-decreasing effects of pelvic belts could not be attributed to altered muscle activity, pelvic morphometry or body balance in a static short-term application. Long-term belt effects will therefore be of prospective interest.

  1. Pelvic Belt Effects on Pelvic Morphometry, Muscle Activity and Body Balance in Patients with Sacroiliac Joint Dysfunction

    Science.gov (United States)

    Soisson, Odette; Lube, Juliane; Germano, Andresa; Hammer, Karl-Heinz; Josten, Christoph; Sichting, Freddy; Winkler, Dirk; Milani, Thomas L.; Hammer, Niels

    2015-01-01

    Introduction The sacroiliac joint (SIJ) is frequently involved in low back and pelvic girdle pain. However, morphometrical and functional characteristics related to SIJ pain are poorly defined. Pelvic belts represent one treatment option, but evidence still lacks as to their pain-reducing effects and the mechanisms involved. Addressing these two issues, this case-controlled study compares morphometric, functional and clinical data in SIJ patients and healthy controls and evaluates the effects of short-term pelvic belt application. Methods Morphometric and functional data pertaining to pelvic belt effects were compared in 17 SIJ patients and 17 controls. Lumbar spine and pelvis morphometries were obtained from 3T magnetic resonance imaging. Functional electromyography data of pelvis and leg muscles and center of pressure excursions were measured in one-leg stance. The numerical rating scale was used to evaluate immediate pain-reducing effects. Results Pelvic morphometry was largely unaltered in SIJ patients and also by pelvic belt application. The angle of lumbar lateral flexion was significantly larger in SIJ patients without belt application. Muscle activity and center of pressure were unaffected by SIJ pain or by belt application in one-leg stance. Nine of 17 patients reported decreased pain intensities under moderate belt application, four reported no change and four reported increased pain intensity. For the entire population investigated here, this qualitative description was not confirmed on a statistical significant level. Discussion Minute changes were observed in the alignment of the lumbar spine in the frontal plane in SIJ patients. The potential pain-decreasing effects of pelvic belts could not be attributed to altered muscle activity, pelvic morphometry or body balance in a static short-term application. Long-term belt effects will therefore be of prospective interest. PMID:25781325

  2. Pelvic belt effects on pelvic morphometry, muscle activity and body balance in patients with sacroiliac joint dysfunction.

    Science.gov (United States)

    Soisson, Odette; Lube, Juliane; Germano, Andresa; Hammer, Karl-Heinz; Josten, Christoph; Sichting, Freddy; Winkler, Dirk; Milani, Thomas L; Hammer, Niels

    2015-01-01

    The sacroiliac joint (SIJ) is frequently involved in low back and pelvic girdle pain. However, morphometrical and functional characteristics related to SIJ pain are poorly defined. Pelvic belts represent one treatment option, but evidence still lacks as to their pain-reducing effects and the mechanisms involved. Addressing these two issues, this case-controlled study compares morphometric, functional and clinical data in SIJ patients and healthy controls and evaluates the effects of short-term pelvic belt application. Morphometric and functional data pertaining to pelvic belt effects were compared in 17 SIJ patients and 17 controls. Lumbar spine and pelvis morphometries were obtained from 3T magnetic resonance imaging. Functional electromyography data of pelvis and leg muscles and center of pressure excursions were measured in one-leg stance. The numerical rating scale was used to evaluate immediate pain-reducing effects. Pelvic morphometry was largely unaltered in SIJ patients and also by pelvic belt application. The angle of lumbar lateral flexion was significantly larger in SIJ patients without belt application. Muscle activity and center of pressure were unaffected by SIJ pain or by belt application in one-leg stance. Nine of 17 patients reported decreased pain intensities under moderate belt application, four reported no change and four reported increased pain intensity. For the entire population investigated here, this qualitative description was not confirmed on a statistical significant level. Minute changes were observed in the alignment of the lumbar spine in the frontal plane in SIJ patients. The potential pain-decreasing effects of pelvic belts could not be attributed to altered muscle activity, pelvic morphometry or body balance in a static short-term application. Long-term belt effects will therefore be of prospective interest.

  3. [The Life Impacts and Symptom Distress in Women With Pelvic Organ Prolapse Syndrome Before Pelvic Reconstruction Surgery].

    Science.gov (United States)

    Ko, I-Chen; Lo, Tsia-Shu; Lu, Yu-Ying; Tsao, Lee-Ing

    2017-02-01

    The decision whether or not to undergo pelvic reconstructive surgery is difficult for women suffering from pelvic organ prolapse. However, little research has examined the symptom distress and life impacts that these women face prior to this surgery. Thus, it is crucial that gynecology nurses learn about these life impacts and symptom distresses in order to help these women make the best decisions with regard to surgery. To explore the life impacts and degree of symptom distress in pre-surgery women with pelvic organ prolapse; to explore the relationships between demographic data and the variables of life impact and degree of symptom distress; and to identify the factors that relate to the explainable variance in the life impacts of these women. A cross-sectional and correlational research design was used and a total of 110 women with pelvic organ prolapse who had not yet undergone pelvic reconstruction surgery were recruited in the gynecological clinics of one medical center in Taiwan. Daytime urination frequency was the most prevalent urinary tract symptom noted by the participants; vaginal protrusion was the most prevalent pelvis-related symptom noted; and depression and anxiety were the most prevalent life impacts noted. Moreover, greater lower-urinary-tract symptom distress was associated with greater pelvic-symptom distress. Furthermore, greater lower urinary tract and pelvic symptom distresses were associated with a greater negative impact on life. Education background and pelvis-related symptoms were the explained variances in pre-surgery life impacts. Women with pelvic organ prolapse should pay particular attention to symptoms that include: daytime urinary frequency, vaginal protrusion, and emotional problems including depression and anxiety. Education background and level of symptom distress should be taken into consideration when caring for the life impacts of this vulnerable group of women.

  4. Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor

    International Nuclear Information System (INIS)

    Cheon, Geum Seong; Kim, Chang Uk; Kim, Hoi Nam; Heo, Gyeong Hun; Song, Jin Ho; Hong, Joo Yeong; Jeong, Jae Yong

    2010-01-01

    Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two different modalities. The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head and neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. In case of comparing both simple summation absorbed dose and integration absorbed dose, the

  5. Helical Confinement Concepts

    Energy Technology Data Exchange (ETDEWEB)

    Beidler, C; Brakel, R; Burhenn, R; Dinklage, A; Erckmann, V; Feng, Y; Geiger, J; Hartmann, D; Hirsch, M; Jaenicke, R; Koenig, R; Laqua, H P; Maassberg, H; Wagner, F; Weller, A; Wobig, H [Max-Planck Institut fuer Plasmaphysik, EURATOM Association, Greifswald (Germany)

    2012-09-15

    Stellarators, conceived 1951 by Lyman Spitzer in Princeton, are toroidal devices that confine a plasma in a magnetic field which originates from currents in coils outside the plasma. A plasma current driven by external means, for example by an ohmic transformer, is not required for confinement. Supplying the desired poloidal field component by external coils leads to a helically structured plasma topology. Thus stellarators - or helical confinement devices - are fully three-dimensional in contrast to the toroidal (rotational) symmetry of tokamaks. As stellarators can be free of an inductive current, whose radial distribution depends on the plasma parameters, their equilibrium must not be established via the evolving plasma itself, but to a first order already given by the vacuum magnetic field. They do not need an active control (like positional feedback) and therefore cannot suffer from its failure. The outstanding conceptual advantage of stellarators is the potential of steady state plasma operation without current drive. As there is no need for current drive, the recirculating power is expected to be smaller than in equivalent tokamaks. The lack of a net current avoids current driven instabilities; specifically, no disruptions, no resistive wall modes and no conventional or neoclassical tearing modes appear. Second order pressure-driven currents (Pfirsch-Schlueter, bootstrap) exist but they can be modified and even minimized by the magnetic design. The magnetic configuration of helical devices naturally possesses a separatrix, which allows the implementation of a helically structured divertor for exhaust and impurity control. (author)

  6. Early development of the human pelvic diaphragm

    NARCIS (Netherlands)

    Koch, Wijnandus Franciscus Robertus Maria

    2006-01-01

    The last decade an increasing interest in the pelvic floor can be observed in medical sciences. The lack of data on the development of the human pelvic floor is striking. The early development of the human pelvic diaphragm was studied. Materials and methodsUse was made of 38 human embryos and

  7. [Continuous improvement of portable domestic pelvic floor neuromuscular electrical stimulation on the pelvic floor function of patients with urinary incontinence].

    Science.gov (United States)

    Sun, Zhijing; Zhu, Lan; Lang, Jinghe; Wang, Wei; Shi, Honghui; Pang, Hongxia; Shi, Xinwen

    2015-12-01

    To evaluate continuous improvement of portable domestic pelvic floor neuromuscular electrical stimulation on the pelvic floor function of patients with stress urinary incontinence after short-term pelvic floor electrophysiological treatment in hospital. Totally 60 women with stress urinary incontinence were recruited for this randomized controlled trial. The control group including a total of 30 patients, only received 4 weeks pelvic floor electrophysiological treatment in the hospital. Family consolidation treatment group (experimental group) including 30 patients, after 4-week treatment in hospital, received 12-week of pelvic floor neuromuscular electrical stimulation using portable electrical stimulator at home under the guidance of doctors. In post-treatment 6 months and 9 months, 1-hour pad test was measured for urine leakage, pelvic floor electrical physiological parameters were assessed, and subjective improvement of symptoms of urinary incontinence were evaluated. All these data were analysed to compare the effect of the two groups. In 9 months after treatment, average change of urine leakage, the control group and experiment group were (75±24)% versus (99±3)%, the difference was statistically significant (Pcontinuous improvement of pelvic floor function.

  8. Magnetic resonance imaging of pelvic floor dysfunction.

    Science.gov (United States)

    Lalwani, Neeraj; Moshiri, Mariam; Lee, Jean H; Bhargava, Puneet; Dighe, Manjiri K

    2013-11-01

    Pelvic floor dysfunction is largely a complex problem of multiparous and postmenopausal women and is associated with pelvic floor or organ descent. Physical examination can underestimate the extent of the dysfunction and misdiagnose the disorders. Functional magnetic resonance (MR) imaging is emerging as a promising tool to evaluate the dynamics of the pelvic floor and use for surgical triage and operative planning. This article reviews the anatomy and pathology of pelvic floor dysfunction, typical imaging findings, and the current role of functional MR imaging. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Unilateral and bilateral neck SIB for head and neck cancer patients. Intensity-modulated proton therapy, tomotherapy, and RapidArc

    Energy Technology Data Exchange (ETDEWEB)

    Stromberger, Carmen; Budach, Volker; Ghadjar, Pirus; Wlodarczyk, Waldemar; Marnitz, Simone [Charite - Universitaetsmedizin Berlin, Department of Radiation Oncology and Radiotherapy, Berlin (Germany); Cozzi, Luca; Fogliata, Antonella [Humanitas Cancer Center Milan, Radiotherapy and Radiosurgery Department, Milan (Italy); Jamil, Basil [Klinikum Frankfurt Oder, Praxis fuer Strahlentherapie, Frankfurt Oder (Germany); Raguse, Jan D. [Clinic for Oral and Maxillofacial Surgery, Berlin (Germany); Boettcher, Arne [Charite - Universitaetsmedizin Berlin, Department of Otorhinolaryngology, Berlin (Germany)

    2016-04-15

    To compare simultaneous integrated boost plans for intensity-modulated proton therapy (IMPT), helical tomotherapy (HT), and RapidArc therapy (RA) for patients with head and neck cancer. A total of 20 patients with squamous cell carcinoma of the head and neck received definitive chemoradiation with bilateral (n = 14) or unilateral (n = 6) neck irradiation and were planned using IMPT, HT, and RA with 54.4, 60.8, and 70.4 GyE/Gy in 32 fractions. Dose distributions, coverage, conformity, homogeneity to planning target volumes (PTV)s and sparing of organs at risk and normal tissue were compared. All unilateral and bilateral plans showed excellent PTV coverage and acceptable dose conformity. For unilateral treatment, IMPT delivered substantially lower mean doses to contralateral salivary glands (< 0.001-1.1 Gy) than both rotational techniques did (parotid gland: 6-10 Gy; submandibular gland: 15-20 Gy). Regarding the sparing of classical organs at risk for bilateral treatment, IMPT and HT were similarly excellent and RA was satisfactory. For unilateral neck irradiation, IMPT may minimize the dry mouth risk in this subgroup but showed no advantage over HT for bilateral neck treatment regarding classical organ-at-risk sparing. All methods satisfied modern standards regarding toxicity and excellent target coverage for unilateral and bilateral treatment of head and neck cancer at the planning level. (orig.) [German] Planvergleich von intensitaetsmodulierter Protonentherapie (IMPT), Tomotherapie (HT) und RapidArc-Therapie (RA) fuer Patienten mit Plattenepithelkarzinomen der Kopf-Hals-Region unter Anwendung des simultan integrierten Boost-Konzepts (SIB). Fuer 20 Patienten mit Plattenepithelkarzinomen der Kopf-Hals-Region und bilateraler (n = 14) oder unilateraler (n = 6) zervikaler primaerer Radiochemotherapie erfolgte eine IMPT-, HT- und RA-Planung mit 54,4, 60,8 und 70,4 GyE/Gy in 32 Fraktionen. Die Dosisverteilung, Abdeckung, Konformitaet und Homogenitaet der PTVs sowie die

  10. General architecture of the alpha-helical globule.

    Science.gov (United States)

    Murzin, A G; Finkelstein, A V

    1988-12-05

    A model is presented for the arrangement of alpha-helices in globular proteins. In the model, helices are placed on certain ribs of "quasi-spherical" polyhedra. The polyhedra are chosen so as to allow the close packing of helices around a hydrophobic core and to stress the collective interactions of the individual helices. The model predicts a small set of stable architectures for alpha-helices in globular proteins and describes the geometries of the helix packings. Some of the predicted helix arrangements have already been observed in known protein structures; others are new. An analysis of the three-dimensional structures of all proteins for which co-ordinates are available shows that the model closely approximates the arrangements and packing of helices actually observed. The average deviations of the real helix axes from those in the model polyhedra is +/- 20 degrees in orientation and +/- 2 A in position (1 A = 0.1 nm). We also show that for proteins that are not homologous, but whose helix arrangements are described by the same polyhedron, the root-mean-square difference in the position of the C alpha atoms in the helices is 1.6 to 3.0 A.

  11. Evidence for Mixed Helicity in Erupting Filaments

    Science.gov (United States)

    Muglach, K.; Wang, Y.-M.; Kliem, B.

    2009-09-01

    Erupting filaments are sometimes observed to undergo a rotation about the vertical direction as they rise. This rotation of the filament axis is generally interpreted as a conversion of twist into writhe in a kink-unstable magnetic flux rope. Consistent with this interpretation, the rotation is usually found to be clockwise (as viewed from above) if the post-eruption arcade has right-handed helicity, but counterclockwise if it has left-handed helicity. Here, we describe two non-active-region filament events recorded with the Extreme-Ultraviolet Imaging Telescope on the Solar and Heliospheric Observatory in which the sense of rotation appears to be opposite to that expected from the helicity of the post-event arcade. Based on these observations, we suggest that the rotation of the filament axis is, in general, determined by the net helicity of the erupting system, and that the axially aligned core of the filament can have the opposite helicity sign to the surrounding field. In most cases, the surrounding field provides the main contribution to the net helicity. In the events reported here, however, the helicity associated with the filament "barbs" is opposite in sign to and dominates that of the overlying arcade.

  12. Applications of 2D helical vortex dynamics

    DEFF Research Database (Denmark)

    Okulov, Valery; Sørensen, Jens Nørkær

    2010-01-01

    In the paper, we show how the assumption of helical symmetry in the context of 2D helical vortices can be exploited to analyse and to model various cases of rotating flows. From theory, examples of three basic applications of 2D dynamics of helical vortices embedded in flows with helical symmetry...... of the vorticity field are addressed. These included some of the problems related to vortex breakdown, instability of far wakes behind rotors and vortex theory of ideal rotors....

  13. Knowledge of the pelvic floor in nulliparous women

    OpenAIRE

    Neels, Hedwig; Wyndaele, Jean-Jacques; Tjalma, Wiebren A. A.; De Wachter, Stefan; Wyndaele, Michel; Vermandel, Alexandra

    2016-01-01

    [Purpose] Proper pelvic floor function is important to avoid serious dysfunctions including incontinence, prolapse, and sexual problems. The current study evaluated the knowledge of young nulliparous women about their pelvic floor and identified what additional information they wanted. [Subjects and Methods] In this cross-sectional survey, a validated, 36 item questionnaire was distributed to 212 nulliparous women. The questionnaire addressed demography, pelvic floor muscles, pelvic floor dys...

  14. Imaging findings in idiopathic pelvic fibrosis

    International Nuclear Information System (INIS)

    Wiesner, W.; Bongartz, G.; Stoffel, F.

    2001-01-01

    Two patients presented with ureteric obstruction, and voiding symptoms and constipation, respectively, and were examined by means of intravenous urography and computed tomography. One patient was additionally examined by means of MR tomography. After CT (performed in both patients) and MRT (performed in one patient) had shown a diffuse, contrast-enhancing, infiltrating process in the small pelvis with infiltration of adjacent organs and vessels, surgical biopsy proved the diagnosis of idopathic pelvic fibrosis. Extension of retroperitoneal fibrosis below the pelvic rim is very rare. Clinical symptoms of pelvic fibrosis are variable and imaging findings may lead to a broad list of differential diagnoses. We present two patients with idiopathic pelvic fibrosis and discuss radiological findings and differential diagnoses of this rare disease. (orig.)

  15. Imaging findings in idiopathic pelvic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Wiesner, W.; Bongartz, G. [Inst. of Diagnostic Radiology University Hospital Basel (Switzerland); Stoffel, F. [Inst. of Urology, University Hospital Basel (Switzerland)

    2001-04-01

    Two patients presented with ureteric obstruction, and voiding symptoms and constipation, respectively, and were examined by means of intravenous urography and computed tomography. One patient was additionally examined by means of MR tomography. After CT (performed in both patients) and MRT (performed in one patient) had shown a diffuse, contrast-enhancing, infiltrating process in the small pelvis with infiltration of adjacent organs and vessels, surgical biopsy proved the diagnosis of idopathic pelvic fibrosis. Extension of retroperitoneal fibrosis below the pelvic rim is very rare. Clinical symptoms of pelvic fibrosis are variable and imaging findings may lead to a broad list of differential diagnoses. We present two patients with idiopathic pelvic fibrosis and discuss radiological findings and differential diagnoses of this rare disease. (orig.)

  16. Physical activity and the pelvic floor.

    Science.gov (United States)

    Nygaard, Ingrid E; Shaw, Janet M

    2016-02-01

    Pelvic floor disorders are common, with 1 in 4 US women reporting moderate to severe symptoms of urinary incontinence, pelvic organ prolapse, or fecal incontinence. Given the high societal burden of these disorders, identifying potentially modifiable risk factors is crucial. Physical activity is one such potentially modifiable risk factor; the large number of girls and women participating in sport and strenuous training regimens increases the need to understand associated risks and benefits of these exposures. The aim of this review was to summarize studies reporting the association between physical activity and pelvic floor disorders. Most studies are cross-sectional and most include small numbers of participants. The primary findings of this review include that urinary incontinence during exercise is common and is more prevalent in women during high-impact sports. Mild to moderate physical activity, such as brisk walking, decreases both the odds of having and the risk of developing urinary incontinence. In older women, mild to moderate activity also decreases the odds of having fecal incontinence; however, young women participating in high-intensity activity are more likely to report anal incontinence than less active women. Scant data suggest that in middle-aged women, lifetime physical activity increases the odds of stress urinary incontinence slightly and does not increase the odds of pelvic organ prolapse. Women undergoing surgery for pelvic organ prolapse are more likely to report a history of heavy work than controls; however, women recruited from the community with pelvic organ prolapse on examination report similar lifetime levels of strenuous activity as women without this examination finding. Data are insufficient to determine whether strenuous activity while young predisposes to pelvic floor disorders later in life. The existing literature suggests that most physical activity does not harm the pelvic floor and does provide numerous health benefits for

  17. Theoretical aspects of magnetic helicity

    International Nuclear Information System (INIS)

    Hammer, J.H.

    1985-01-01

    The magnetic helicity, usually defined as K=integralA.Bdv, where A is the vector potential and B the magnetic field, measures the topological linkage of magnetic fluxes. Helicity manifests itself in the twistedness and knottedness of flux tubes. Its significance is that it is an ideal MHD invariant. While the helicity formalism has proven very useful in understanding reversed field pinch and spheromak behavior, some problems exist in applying the method consistently for complex (e.g., toroidal) conductor geometries or in situations where magnetic flux penetrates conducting walls. Recent work has attempted to generalize K to allow for all possible geometries

  18. Intra-abdominal gout mimicking pelvic abscess

    International Nuclear Information System (INIS)

    Chen, Chia-Hui; Chen, Clement Kuen-Huang; Yeh, Lee-Ren; Pan, Huay-Ban; Yang, Chien-Fang

    2005-01-01

    Gout is the most common crystal-induced arthritis. Gouty tophi typically deposit in the extremities, especially toes and fingers. We present an unusual case of intrapelvic tophaceous gout in a patient suffering from chronic gouty arthritis. CT and MRI of the abdomen and pelvic cavity disclosed calcified gouty tophi around both hips, and a cystic lesion with peripheral enhancement in the pelvic cavity along the course of the iliopsoas muscle. The intra-abdominal tophus mimicked pelvic abscess. (orig.)

  19. Intra-abdominal gout mimicking pelvic abscess

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chia-Hui; Chen, Clement Kuen-Huang [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (Taiwan); National Yang-Ming University, School of Medicine, Taipei (Taiwan); Yeh, Lee-Ren; Pan, Huay-Ban; Yang, Chien-Fang [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (Taiwan)

    2005-04-01

    Gout is the most common crystal-induced arthritis. Gouty tophi typically deposit in the extremities, especially toes and fingers. We present an unusual case of intrapelvic tophaceous gout in a patient suffering from chronic gouty arthritis. CT and MRI of the abdomen and pelvic cavity disclosed calcified gouty tophi around both hips, and a cystic lesion with peripheral enhancement in the pelvic cavity along the course of the iliopsoas muscle. The intra-abdominal tophus mimicked pelvic abscess. (orig.)

  20. Gynecological pelvic pain as emergency pathology.

    Science.gov (United States)

    Rivera Domínguez, A; Mora Jurado, A; García de la Oliva, A; de Araujo Martins-Romeo, D; Cueto Álvarez, L

    Acute pelvic pain is a common condition in emergency. The sources of acute pelvic pain are multifactorial, so it is important to be familiar with this type of pathologies. The purpose of this article is review the main causes of gynecological acute pelvic pain and their radiologic appearances to be able to make an accurate diagnosis and provide objective criteria for patient management. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Effects of Magnetic and Kinetic Helicities on the Growth of Magnetic Fields in Laminar and Turbulent Flows by Helical Fourier Decomposition

    Energy Technology Data Exchange (ETDEWEB)

    Linkmann, Moritz; Sahoo, Ganapati; Biferale, Luca [Department of Physics and INFN, University of Rome Tor Vergata, Via della Ricerca Scientifica 1, I-00133 Rome (Italy); McKay, Mairi; Berera, Arjun [School of Physics and Astronomy, University of Edinburgh, Peter Guthrie Tait Road, EH9 3FD, Edinburgh (United Kingdom)

    2017-02-10

    We present a numerical and analytical study of incompressible homogeneous conducting fluids using a helical Fourier representation. We analytically study both small- and large-scale dynamo properties, as well as the inverse cascade of magnetic helicity, in the most general minimal subset of interacting velocity and magnetic fields on a closed Fourier triad. We mainly focus on the dependency of magnetic field growth as a function of the distribution of kinetic and magnetic helicities among the three interacting wavenumbers. By combining direct numerical simulations of the full magnetohydrodynamics equations with the helical Fourier decomposition, we numerically confirm that in the kinematic dynamo regime the system develops a large-scale magnetic helicity with opposite sign compared to the small-scale kinetic helicity, a sort of triad-by-triad α -effect in Fourier space. Concerning the small-scale perturbations, we predict theoretically and confirm numerically that the largest instability is achived for the magnetic component with the same helicity of the flow, in agreement with the Stretch–Twist–Fold mechanism. Vice versa, in the presence of Lorentz feedback on the velocity, we find that the inverse cascade of magnetic helicity is mostly local if magnetic and kinetic helicities have opposite signs, while it is more nonlocal and more intense if they have the same sign, as predicted by the analytical approach. Our analytical and numerical results further demonstrate the potential of the helical Fourier decomposition to elucidate the entangled dynamics of magnetic and kinetic helicities both in fully developed turbulence and in laminar flows.

  2. Triple pelvic ring fixation in patients with severe pregnancy-related low back and pelvic pain.

    NARCIS (Netherlands)

    Zwienen, C.M. van; Bosch, E.W. van den; Snijders, C.J.; Vugt, A.B. van

    2004-01-01

    STUDY DESIGN: Single-group prospective follow-up study. OBJECTIVES: To assess the functional outcome of internal fixation of the pelvic ring in patients with severe pregnancy-related low back and pelvic pain (PLBP) in whom all other treatments failed. BACKGROUND DATA: More than half of all pregnant

  3. Electronic transport in single-helical protein molecules: Effects of multiple charge conduction pathways and helical symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Kundu, Sourav, E-mail: sourav.kunduphy@gmail.com; Karmakar, S.N.

    2016-07-15

    We propose a tight-binding model to investigate electronic transport properties of single helical protein molecules incorporating both the helical symmetry and the possibility of multiple charge transfer pathways. Our study reveals that due to existence of both the multiple charge transfer pathways and helical symmetry, the transport properties are quite rigid under influence of environmental fluctuations which indicates that these biomolecules can serve as better alternatives in nanoelectronic devices than its other biological counterparts e.g., single-stranded DNA.

  4. High-n helicity-induced shear Alfven eigenmodes

    International Nuclear Information System (INIS)

    Nakajima, N.; Cheng, C.Z.; Okamoto, M.

    1992-05-01

    The high-n Helicity-induced shear Alfven Eigenmodes (HAE) are considered both analytically and numerically for the straight helical magnetic system, where n is the toroidal mode number. The eigenmode equation for the high-n HAE modes is derived along the field line and with the aid of the averaging method is shown to reduce to the Mathieu equation asymptotically. The discrete HAE modes are shown to exist inside the continuum spectrum gaps. The continuous spectrum gaps appear around ω 2 = ω A 2 [N(lι-m)/2] 2 for N = 1,2,.., where ω A is the toroidal Alfven transit frequency, and l, m, and ι are the polarity of helical coils, the toroidal pitch number of helical coils, and the rotational transform, respectively. For the same ω A and ι, the frequency of the helical continuum gap is larger than that of the continuum gap in tokamak plasmas by |l-ι -1 m|. The polarity of helical coils l plays a crucial role in determining the spectrum gaps and the properties of the high-n HAE modes. The spectrum gaps near the magnetic axis are created by the helical ripple with circular flux surfaces for l = 1, and ≥ 3 helicals. For l = 2 helical systems, the spectrum gaps are created by the ellipticity of the flux surfaces. These analytical results for the continuum gaps and the existence of the high-n HAE modes in the continuum gaps are confirmed numerically for the l = 2 case, and we find that the HAE modes exist for mode structures with the even and the odd parities. (author)

  5. Employing Helicity Amplitudes for Resummation

    NARCIS (Netherlands)

    Moult, I.; Stewart, I.W.; Tackmann, F.J.; Waalewijn, W.J.

    2015-01-01

    Many state-of-the-art QCD calculations for multileg processes use helicity amplitudes as their fundamental ingredients. We construct a simple and easy-to-use helicity operator basis in soft-collinear effective theory (SCET), for which the hard Wilson coefficients from matching QCD onto SCET are

  6. Radiographic assessment of pelvic trauma

    International Nuclear Information System (INIS)

    Rubenstein, J.D.

    1983-01-01

    Assessment of pelvic fractures requires an understanding of the bony and soft-tissue anatomy of the pelvis. Pelvic injuries may be classified into major and minor groups. Minor fractures usually result from athletic trauma in the young or falls in the elderly and can generally be adequately evaluated with routine radiography. Major fractures are most often caused by motor vehicle accidents, falls from a height or industrial accidents and require more sophisticated examination. However, the investigation of injuries in either category should be directed by a knowledge of the history and physical findings. The classification of pelvic injuries used at Sunnbrook Medical Centre is based on mechanisms of injury

  7. Self-assembly of a double-helical complex of sodium.

    Science.gov (United States)

    Bell, T W; Jousselin, H

    1994-02-03

    Spontaneous self-organization of helical and multiple-helical molecular structures occurs on several levels in living organisms. Key examples are alpha-helical polypeptides, double-helical nucleic acids and helical protein structures, including F-actin, microtubules and the protein sheath of the tobacco mosaic virus. Although the self-assembly of double-helical transition-metal complexes bears some resemblance to the molecular organization of double-stranded DNA, selection between monohelical, double-helical and triple-helical structures is determined largely by the size and geometrical preference of the tightly bound metal. Here we present an example of double-helical assembly induced by the weaker and non-directional interactions of an alkali-metal ion with an organic ligand that is pre-organized into a coil. We have characterized the resulting complex by two-dimensional NMR and fast-atom-bombardment mass spectrometry. These results provide a step toward the creation of molecular tubes or ion channels consisting of intertwined coils.

  8. Helicity multiplexed broadband metasurface holograms.

    Science.gov (United States)

    Wen, Dandan; Yue, Fuyong; Li, Guixin; Zheng, Guoxing; Chan, Kinlong; Chen, Shumei; Chen, Ming; Li, King Fai; Wong, Polis Wing Han; Cheah, Kok Wai; Pun, Edwin Yue Bun; Zhang, Shuang; Chen, Xianzhong

    2015-09-10

    Metasurfaces are engineered interfaces that contain a thin layer of plasmonic or dielectric nanostructures capable of manipulating light in a desirable manner. Advances in metasurfaces have led to various practical applications ranging from lensing to holography. Metasurface holograms that can be switched by the polarization state of incident light have been demonstrated for achieving polarization multiplexed functionalities. However, practical application of these devices has been limited by their capability for achieving high efficiency and high image quality. Here we experimentally demonstrate a helicity multiplexed metasurface hologram with high efficiency and good image fidelity over a broad range of frequencies. The metasurface hologram features the combination of two sets of hologram patterns operating with opposite incident helicities. Two symmetrically distributed off-axis images are interchangeable by controlling the helicity of the input light. The demonstrated helicity multiplexed metasurface hologram with its high performance opens avenues for future applications with functionality switchable optical devices.

  9. A randomized clinical trial comparing pelvic floor muscle training to a Pilates exercise program for improving pelvic muscle strength.

    Science.gov (United States)

    Culligan, Patrick J; Scherer, Janet; Dyer, Keisha; Priestley, Jennifer L; Guingon-White, Geri; Delvecchio, Donna; Vangeli, Margi

    2010-04-01

    The purpose of this study is to determine whether a Pilates exercise program and a pelvic floor muscle-training (PFMT) program could provide similar improvements in pelvic muscle strength. Sixty-two women with little or no pelvic floor dysfunction were randomized to Pilates or PFMT. Each group had 24 biweekly 1-h sessions with either a physical therapist or Pilates instructor. Strength was measured via perineometry (cmH(2)O). Two questionnaires--pelvic floor distress inventory (PFDI-20) and pelvic floor impact questionnaire (PFIQ-7)--were also collected. At baseline, the Pilates and PFMT groups measured 14.9 +/- 12.5 and 12.5 +/- 10.4 cmH(2)O, respectively (p = 0.41). Both the Pilates and PFMT groups got stronger (6.2 +/- 7.5 cmH(2)O, p = 0.0002 and 6.6 +/- 7.4 cmH(2)O, p = 0.0002, respectively), with no difference between groups p = 0.85. PFIQ and PFDI scores improved from baseline but not between groups. Further study is required to determine if Pilates can actually treat pelvic floor dysfunction.

  10. The Number of Positive Pelvic Lymph Nodes and Multiple Groups of Pelvic Lymph Node Metastasis Influence Prognosis in Stage IA-IIB Cervical Squamous Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Yu Liu

    2015-01-01

    Full Text Available Background: Pelvic lymph node metastasis (LNM is an important prognostic factor in cervical cancer. Cervical squamous cell carcinoma accounts for approximately 75-80% of all cervical cancers. Analyses of the effects of the number of positive lymph nodes (LNs, unilateral versus bilateral pelvic LNM and a single group versus multiple groups of pelvic LNM on survival and recurrence of cervical squamous cell carcinoma are still lacking. The study aimed to analyze the effects of the number of positive pelvic LNs and a single group versus multiple groups of pelvic LNM on survival and recurrence. Methods: We performed a retrospective review of 296 patients diagnosed with Stage IA-IIB cervical squamous cell carcinoma who received extensive/sub-extensive hysterectomy with pelvic lymphadenectomy/pelvic LN sampling at Peking University People′s Hospital from November 2004 to July 2013. Ten clinicopathological variables were evaluated as risk factors for pelvic LNM: Age at diagnosis, gravidity, clinical stage, histological grade, tumor diameter, lymph-vascular space involvement (LVSI, depth of cervical stromal invasion, uterine invasion, parametrial invasion, and neoadjuvant chemotherapy. Results: The incidence of pelvic LNM was 20.27% (60/296 cases. Pelvic LNM (P = 0.00 was significantly correlated with recurrence. Pelvic LNM (P = 0.00, the number of positive pelvic LNs (P = 0.04 and a single group versus multiple groups of pelvic LNM (P = 0.03 had a significant influence on survival. Multivariate analysis revealed that LVSI (P = 0.00, depth of cervical stromal invasion (P = 0.00 and parametrial invasion (P = 0.03 were independently associated with pelvic LNM. Conclusions: Patients with pelvic LNM had a higher recurrence rate and poor survival outcomes. Furthermore, more than 2 positive pelvic LNs and multiple groups of pelvic LNM appeared to identify patients with worse survival outcomes in node-positive IA-IIB cervical squamous cell carcinoma. LVSI

  11. [Quality of life in women with pelvic floor dysfunction].

    Science.gov (United States)

    Segedi, Ljiljana Mladenović; Ilić, Katarina Parezanović; Curcić, Aleksandar; Visnjevac, Nemanja

    2011-11-01

    Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfaction in adult women with pelvic organ prolapse presenting to tertiary care clinic for surgical treatment. This prospective case-control study included 50 patients who presented to tertiary care gynecology clinic for surgical treatment and 50 controls with normal pelvic floor support and without urinary incontinence who presented tertiary care gynecology clinic for other reasons. Both, patients and controls, completed two quastionnaires recommended for the evaluation of symptoms (Pelvic floor distress inventory - short forms) and quality of life impact (Pelvic floor impact questionnaire - short form) of pelvic organ prolapse, and Body Image Scale. The patients scored significantly worse on the prolapse, urinary, colorectal scales and overall score of Pelvic floor distress inventory--20 than controls subjects (134.91 vs 78.08; p self-conscious (78% vs 42%; p body. There was a positive correlation between decreased quality of life and body image in women with pelvic dysfunction. Women with pelvic floor dysfunction have decreased quality of life and body image.

  12. Occupational lifting and pelvic pain during pregnancy:

    DEFF Research Database (Denmark)

    Larsen, Pernille Stemann; Strandberg-Larsen, Katrine; Juhl, Mette

    2013-01-01

    OBJECTIVES: Pelvic pain during pregnancy is a common ailment, and the disease is a major cause of sickness absence during pregnancy. It is plausible that occupational lifting may be a risk factor of pelvic pain during pregnancy, but no previous studies have examined this specific exposure. The aim...... of this study was to examine the association between occupational lifting and pelvic pain during pregnancy. METHODS: The study comprised 50 143 pregnant women, enrolled in the Danish National Birth Cohort in the period from 1996-2002. During pregnancy, the women provided information on occupational lifting...... (weight load and daily frequency), and six months post partum on pelvic pain. Adjusted odds ratios for pelvic pain during pregnancy according to occupational lifting were calculated by logistic regression. RESULTS: Any self-reported occupational lifting (>1 time/day and loads weighing >10 kg...

  13. Beta-helical polymers from isocyanopeptides

    NARCIS (Netherlands)

    Cornelissen, J.J.L.M.; Donners, J.J.J.M.; Gelder, de R.; Graswinckel, W.S.; Metselaar, G.A.; Rowan, A.E.; Sommerdijk, N.A.J.M.; Nolte, R.J.M.

    2001-01-01

    Polymerization of isocyanopeptides results in the formation of high molecular mass polymers that fold in a proteinlike fashion to give helical strands in which the peptide chains are arranged in ß-sheets. The ß-helical polymers retain their structure in water and unfold in a cooperative process at

  14. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    Science.gov (United States)

    Lagisetty, Jyothi; Slovis, Thomas; Thomas, Ronald; Knazik, Stephen; Stankovic, Curt

    2012-07-01

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients.

  15. Pelvic pain in a young patient: Sclerosing stromal tumor

    Directory of Open Access Journals (Sweden)

    Huriye Ayşe Parlakgümüş

    2013-03-01

    Full Text Available Introduction: Sclerosing stromal tumors are rare, benign sex chord stromal tumors. They are usually unilateral and are seen in second or third decades. The complaint at admission may be menstrual irregularity, pelvic pain, palpable pelvic mass, precocious puberty and postmenopausal bleeding. Because the complaint at admission and radiological findings are not specific to SSTs preoperative diagnosis is challenging. Herein we present the sonographical, intraoperative and histopathological findings of a SST diagnosed during laparoscopy in a patient who admitted with chronic pelvic pain and received pelvic inflammatory disease and endometriosis treatment and differential diagnosis of SSTs with the other ovarian tumors. Case report: 24 years old nulliparous patient first admitted to the gynecology department with the complaint of foul smelling vaginal discharge and pelvic pain. The diagnosis was pelvic inflammatory disease and the patient received antibiotics. The pelvic examination was normal except the mass in the right ovary which had similar echogenity to the ovary. Because of the pelvic pain the mass was assumed to be an endometrioma and the patient was prescribed an oral contraceptive treatment for 3 months. Because of the persistent pelvic pain a diagnostic laparoscopy was performed which revealed a 2 cm, pinkish- white, exophytic lesion originating from the right ovary. Pathological examination reported the mass to be a sclerosing stromal tumor. After the treatment the patient no longer complained of vaginal discharge but pelvic pain still persisted. After the operation the patient no longer complained of pelvic pain. Conclusion: Although SSTs are rare, they should be kept in mind when a young patient admits with menstrual irregularity, pelvic pain and hirsutism, particularly if the pain is refractory to treatment.

  16. SU-E-T-407: Evaluation of Four Commercial Dosimetry Systems for Routine Patient-Specific Tomotherapy Delivery Quality Assurance

    International Nuclear Information System (INIS)

    Xing, A; Arumugam, S; Deshpande, S; George, A; Holloway, L; Vial, P; Goozee, G

    2014-01-01

    Purpose: The purpose of this project was to evaluate the performance of four commercially available dosimetry systems for Tomotherapy delivery quality assurance (DQA). Methods: Eight clinical patient plans were chosen to represent a range of treatment sites and typical clinical plans. Four DQA plans for each patient plan were created using the TomoTherapy DQA Station (Hi-Art version 4.2.1) on CT images of the ScandiDose Delta4, IBA MatriXX Evolution, PTW Octavius 4D and Sun Nuclear ArcCHECK phantoms. Each detector was calibrated following the manufacture-provided procedure. No angular response correction was applied. All DQA plans for each detector were delivered on the Tomotherapy Hi-Art unit in a single measurement session but on different days. The measured results were loaded into the vendor supplied software for each QA system for comparison with the TPS-calculated dose. The Gamma index was calculated using 3%/3mm, 2%/2mm with 10% dose threshold of maximum TPS calculated dose. Results: Four detector systems showed comparable gamma pass rates for 3%/3m, which is recommended by AAPM TG119 and commonly used within the radiotherapy community. The averaged pass rates ± standard deviation for all DQA plans were (98.35±1.97)% for ArcCHECK, (99.9%±0.87)% for Matrix, (98.5%±5.09)% for Octavius 4D, (98.7%±1.27)% for Delata4. The rank of the gamma pass rate for individual plans was consistent between detectors. Using 2%/2mm Gamma criteria for analysis, the Gamma pass rate decreased on average by 9%, 8%, 6.6% and 5% respectively. Profile and Gamma failure map analysis using the software tools from each dosimetry system indicated that decreased passing rate is mainly due to the threading effect of Tomo plan. Conclusion: Despite the variation in detector type and resolution, phantom geometry and software implementation, the four systems demonstrated similar dosimetric performance, with the rank of the gamma pass rate consistent for the plans considered

  17. Single-superfield helical-phase inflation

    Energy Technology Data Exchange (ETDEWEB)

    Ketov, Sergei V., E-mail: ketov@tmu.ac.jp [Department of Physics, Tokyo Metropolitan University, Minami-ohsawa 1-1, Hachioji-shi, Tokyo 192-0397 (Japan); Kavli Institute for the Physics and Mathematics of the Universe (IPMU), The University of Tokyo, Chiba 277-8568 (Japan); Institute of Physics and Technology, Tomsk Polytechnic University, 30 Lenin Ave., Tomsk 634050 (Russian Federation); Terada, Takahiro, E-mail: takahiro@hep-th.phys.s.u-tokyo.ac.jp [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan); Deutsches Elektronen-Synchrotron (DESY), 22607 Hamburg (Germany)

    2016-01-10

    Large-field inflation in supergravity requires the approximate global symmetry needed to protect flatness of the scalar potential. In helical-phase inflation, the U(1) symmetry of the Kähler potential is assumed, the phase part of the complex scalar of a chiral superfield plays the role of inflaton, and the radial part is strongly stabilized. The original model of helical phase inflation, proposed by Li, Li and Nanopoulos (LLN), employs an extra (stabilizer) superfield. We propose a more economical new class of the helical phase inflationary models without a stabilizer superfield. As the specific examples, the quadratic, the natural, and the Starobinsky-type inflationary models are studied in our approach.

  18. Three dimensional conformal irradiation with intensity modulation by tomo-therapy at the skull base in three patients with a acrochordoma and a patient with a chondrosarcoma; Irradiation conformationnelle tridimensionnelle avec modulation d'intensite par tomotherapie de la base du crane chez 3 patients atteints d'un chordome et un patient atteint d'un chondrosarcome

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.; Meyer, P.; Niederst, C.; Antoni, D.; Karamanoukian, D. [Centre de lutte contre le cancer Paul-Strauss, 67 - Strasbourg (France); Froelich, S.; Boyer, P. [Hopital Universitaire de Hautepierre, 67 - Strasbourg (France); George, B. [Hopital Universitaire Lariboisiere, AP-HP, 75 - Paris (France)

    2009-10-15

    The tomo-therapy of acrochordomas and chondrosarcomas of the skull base is possible. The dose distribution is satisfying the tolerance is acceptable. A dosimetry comparison with protons is being. (N.C.)

  19. A real-scale helical coil winding trial of the Large Helical Device

    International Nuclear Information System (INIS)

    Senba, T.; Yamamoto, T.; Tamaki, T.; Asano, K.; Suzuki, S.; Yamauchi, T.; Uchida, K.; Nakanishi, K.; Yamagiwa, T.; Suzuki, S.; Miyoshi, R.; Sasa, H.; Watanabe, S.; Tatemura, M.; Hatada, N.; Yamaguchi, S.; Imagawa, S.; Yanagi, N.; Satow, T.; Yamamoto, J.; Motojima, O.

    1995-01-01

    A real-scale helical coil winding trial of the Large Helical Device (LHD) has been conducted for a study of coil winding configuration and winding methods and for exhibiting the state of the art. It includes construction and test run of a specifically designed winding machine and development of various manufacturing methods for accurate coil winding. It has been carried out in Hitachi Works before in situ winding, and has provided much needed engineering data for construction of the LHD. (orig.)

  20. On the helicity of open magnetic fields

    International Nuclear Information System (INIS)

    Prior, C.; Yeates, A. R.

    2014-01-01

    We reconsider the topological interpretation of magnetic helicity for magnetic fields in open domains, and relate this to the relative helicity. Specifically, our domains stretch between two parallel planes, and each of these ends may be magnetically open. It is demonstrated that, while the magnetic helicity is gauge-dependent, its value in any gauge may be physically interpreted as the average winding number among all pairs of field lines with respect to some orthonormal frame field. In fact, the choice of gauge is equivalent to the choice of reference field in the relative helicity, meaning that the magnetic helicity is no less physically meaningful. We prove that a particular gauge always measures the winding with respect to a fixed frame, and propose that this is normally the best choice. For periodic fields, this choice is equivalent to measuring relative helicity with respect to a potential reference field. However, for aperiodic fields, we show that the potential field can be twisted. We prove by construction that there always exists a possible untwisted reference field.

  1. Pelvic Mass Due to Transmigrated IUD

    Directory of Open Access Journals (Sweden)

    Nadereh Behtash

    2010-03-01

    Full Text Available Intrauterine device (IUD, a conventional method of contraception is rarely associated with uterine perforation and extra uterine dislocation. A 29 years old woman complaining of vaginal bleeding was referred for pelvic mass identified in ultrasound. The mass was confirmed with CT scan. In laparatomy we found an IUD in cul-de-sac and pelvic mass was apparently an organized hematoma. Transmigrated IUD can induce organized hematomas presenting as a pelvic mass."n© 2010 Tehran University of Medical Sciences. All rights reserved.

  2. Pelvic Pain

    Science.gov (United States)

    ... OLPP) Office of Science Policy, Reporting, and Program Analysis (OSPRA) Division of Extramural Research (DER) Extramural Scientific ... treat my pain? Can pelvic pain affect my emotional well-being? How can I cope with long- ...

  3. Pelvic Exam

    Science.gov (United States)

    ... each step so that nothing comes as a surprise to you. After the pelvic exam After the ... Clinic does not endorse any of the third party products and services advertised. Advertising and sponsorship policy ...

  4. Pelvic floor function during and after first pregnancy

    NARCIS (Netherlands)

    Brummen, H.J. van

    2006-01-01

    This study evaluated the effects the first pregnancy and childbirth on the pelvic floor. Pregnancy and vaginal delivery can negatively affect pelvic floor function. Micturition symptoms, defecation symptoms and sexual dysfunction are all signs of an impaired pelvic floor function. These symptoms are

  5. Preoperative evaluation of locally spreaded pelvic tumors

    International Nuclear Information System (INIS)

    Baramia, M.; Todua, F.; Gotsadze, D.; Khutulashvili, N.; Lashkhi, K.; Nadareishvili, A.

    1998-01-01

    Am of the study: preoperative evaluation of patients with locally advanced pelvic tumors subjected to pelvic exenteration. Determine operability to avoid explorative laparatomies, which cause serious complications in these patients. Evaluate condition of urinary system in case of this pathology. Materials and methods: 34 patients with locally advanced pelvic tumors where pelvic exenteration was attempted were studied. Along with other methods of diagnostic CT and MRI were performed. Results: In all patients secondary involvement of the urinary bladder was noted. In 30 patients CT and MR findings were confirmed (88,2%) intraoperatively and different types of pelvic organs exenteration were performed. In 1 case spread of tomoruos infiltrate to the pelvic wall and common iliac vessels was detected intraoperatively (patient had history of radiation therapy). In 2 cases carcinomatosis of the peritoneum was found. In 1 case involvement of urinary bladder was simulated by close attachment of enlarged uterus. Conclusion: Obtained results show, that CT and MR are highly informative methods of disease spread evaluation and thus determining operability. Radiotherapy performed prior to operation sets difficulties in differentiation for tumourous infiltrate and post-radiotherapy changes in pelvis. (Full text)

  6. Physical exercise and pelvic girdle pain in pregnancy

    DEFF Research Database (Denmark)

    Andersen, Linda Kahr; Backhausen, Mette; Hegaard, Hanne Kristine

    2015-01-01

    OBJECTIVE: Pelvic girdle pain is a frequent cause of sick leave among pregnant women in Denmark. Studies regarding prevention of pelvic girdle pain are sparse. The aim of this study was to examine the association between physical exercise and pelvic girdle pain in pregnancy. STUDY DESIGN: A nested...... case-control study within the Danish National Birth Cohort (n = 5304). METHODS: This study used self-reported data on pelvic girdle pain obtained from an interview six months after childbirth. Information on physical exercise was obtained from the pregnancy interview around gestational week 16....... The association was estimated using logistic regression analysis. RESULTS: Physical exercise in pregnancy was associated with decreased risk of overall pelvic girdle pain (OR = 0.87; 95% CI: 0.77-0.99, p = 0.028). Tests for trend indicated decreasing odds for pelvic girdle pain with increasing number of hours per...

  7. Recognition and Management of Nonrelaxing Pelvic Floor Dysfunction

    Science.gov (United States)

    Faubion, Stephanie S.; Shuster, Lynne T.; Bharucha, Adil E.

    2012-01-01

    Nonrelaxing pelvic floor dysfunction is not widely recognized. Unlike in pelvic floor disorders caused by relaxed muscles (eg, pelvic organ prolapse or urinary incontinence, both of which often are identified readily), women affected by nonrelaxing pelvic floor dysfunction may present with a broad range of nonspecific symptoms. These may include pain and problems with defecation, urination, and sexual function, which require relaxation and coordination of pelvic floor muscles and urinary and anal sphincters. These symptoms may adversely affect quality of life. Focus on the global symptom complex, rather than the individual symptoms, may help the clinician identify the condition. The primary care provider is in a position to intervene early, efficiently, and effectively by (1) recognizing the range of symptoms that might suggest nonrelaxing pelvic floor dysfunction, (2) educating patients, (3) performing selective tests when needed to confirm the diagnosis, and (4) providing early referral for physical therapy. PMID:22305030

  8. Helicity-flip in particle production on nuclei

    International Nuclear Information System (INIS)

    Faeldt, G.

    1977-01-01

    Coherent nuclear production processes are generally analyzed assuming helicity conserving production amplitudes. In view of the uncertainties of the actual helicity structure this could be a dangerous assumption. It is shown that helicity-flip contributions might be part of the explanation of the small effective (pππ)-nucleon cross sections observed in coherent production. (Auth.)

  9. Imaging pelvic floor disorders. 2. rev. ed.

    International Nuclear Information System (INIS)

    Stoker, Jaap; Taylor, Stuart A.; DeLancey, John O.L.

    2008-01-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  10. Imaging pelvic floor disorders. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Amsterdam Univ. (Netherlands). Dept. of Radiology; Taylor, Stuart A. [University College Hospital, London (United Kingdom). Dept. of Specialist X-Ray; DeLancey, John O.L. (eds.) [Michigan Univ., Ann Arbor, MI (United States). L4000 Women' s Hospital

    2008-07-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  11. Geometric validation of MV topograms for patient localization on TomoTherapy

    International Nuclear Information System (INIS)

    Blanco Kiely, Janid P; White, Benjamin M; Low, Daniel A; Qi, Sharon X

    2016-01-01

    Our goal was to geometrically validate the use of mega-voltage orthogonal scout images (MV topograms) as a fast and low-dose alternative to mega-voltage computed tomography (MVCT) for daily patient localization on the TomoTherapy system. To achieve this, anthropomorphic head and pelvis phantoms were imaged on a 16-slice kilo-voltage computed tomography (kVCT) scanner to synthesize kilo-voltage digitally reconstructed topograms (kV-DRT) in the Tomotherapy detector geometry. MV topograms were generated for couch speeds of 1–4 cm s −1 in 1 cm s −1 increments with static gantry angles in the anterior-posterior and left-lateral directions. Phantoms were rigidly translated in the anterior-posterior (AP), superior-inferior (SI), and lateral (LAT) directions to simulate potential setup errors. Image quality improvement was demonstrated by estimating the noise level in the unenhanced and enhanced MV topograms using a principle component analysis-based noise level estimation algorithm. Average noise levels for the head phantom were reduced by 2.53 HU (AP) and 0.18 HU (LAT). The pelvis phantom exhibited average noise level reduction of 1.98 HU (AP) and 0.48 HU (LAT). Mattes Mutual Information rigid registration was used to register enhanced MV topograms with corresponding kV-DRT. Registration results were compared to the known rigid displacements, which assessed the MV topogram localization’s sensitivity to daily positioning errors. Reduced noise levels in the MV topograms enhanced the registration results so that registration errors were  <1 mm. The unenhanced head MV topograms had discrepancies  <2.1 mm and the pelvis topograms had discrepancies  <2.7 mm. Result were found to be consistent regardless of couch speed. In total, 64.7% of the head phantom MV topograms and 60.0% of the pelvis phantom MV topograms exactly measured the phantom offsets. These consistencies demonstrated the potential for daily patient positioning using MV topogram pairs

  12. A Suspected Pelvic Aneurysmal Bone Cyst in Pregnancy

    Directory of Open Access Journals (Sweden)

    Rayan Elkattah

    2013-01-01

    Full Text Available Albeit rare, the majority of identified bone lesions in pregnancy spare the pelvis. Once encountered with a pelvic bone lesion in pregnancy, the obstetrician may face a challenging situation as it is difficult to determine and predict the effects that labor and parturition impart on the pelvic bones. Bone changes and pelvic bone fractures have been well documented during childbirth. The data regarding clinical outcomes and management of pregnancies complicated by pelvic ABCs is scant. Highly suspected to represent an aneurysmal bone cyst, the clinical evaluation of a pelvic lesion in the ilium of a pregnant individual is presented, and modes of delivery in such a scenario are discussed.

  13. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    International Nuclear Information System (INIS)

    Lagisetty, Jyothi; Slovis, Thomas; Thomas, Ronald; Knazik, Stephen; Stankovic, Curt

    2012-01-01

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS <14, positive urinalysis, abdominal pain/tenderness, femur fracture) and five high-risk mechanisms of injury (unrestrained motor vehicle collision [MVC], MVC with ejection, MVC rollover, auto vs. pedestrian, auto vs. bicycle). Pelvic fractures in pediatric major blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients. (orig.)

  14. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Lagisetty, Jyothi [Memorial Hermann Medical Center, Emergency Medicine Department, Houston, TX (United States); Slovis, Thomas [Wayne State University School of Medicine, Department of Radiology, Pediatric Imaging, Children' s Hospital of Michigan, Detroit, MI (United States); Thomas, Ronald [Children' s Hospital of Michigan, Wayne State University of Medicine, Department of Pediatrics, Detroit, MI (United States); Knazik, Stephen; Stankovic, Curt [Wayne State University of Medicine, Division of Emergency Medicine, Children' s Hospital of Michigan, Detroit, MI (United States)

    2012-07-15

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS <14, positive urinalysis, abdominal pain/tenderness, femur fracture) and five high-risk mechanisms of injury (unrestrained motor vehicle collision [MVC], MVC with ejection, MVC rollover, auto vs. pedestrian, auto vs. bicycle). Pelvic fractures in pediatric major blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients. (orig.)

  15. Cryo-EM Structure Determination Using Segmented Helical Image Reconstruction.

    Science.gov (United States)

    Fromm, S A; Sachse, C

    2016-01-01

    Treating helices as single-particle-like segments followed by helical image reconstruction has become the method of choice for high-resolution structure determination of well-ordered helical viruses as well as flexible filaments. In this review, we will illustrate how the combination of latest hardware developments with optimized image processing routines have led to a series of near-atomic resolution structures of helical assemblies. Originally, the treatment of helices as a sequence of segments followed by Fourier-Bessel reconstruction revealed the potential to determine near-atomic resolution structures from helical specimens. In the meantime, real-space image processing of helices in a stack of single particles was developed and enabled the structure determination of specimens that resisted classical Fourier helical reconstruction and also facilitated high-resolution structure determination. Despite the progress in real-space analysis, the combination of Fourier and real-space processing is still commonly used to better estimate the symmetry parameters as the imposition of the correct helical symmetry is essential for high-resolution structure determination. Recent hardware advancement by the introduction of direct electron detectors has significantly enhanced the image quality and together with improved image processing procedures has made segmented helical reconstruction a very productive cryo-EM structure determination method. © 2016 Elsevier Inc. All rights reserved.

  16. Association between preterm labour and pelvic floor muscle function.

    Science.gov (United States)

    Aran, Turhan; Pekgöz, Ipek; Bozkaya, Hasan; Osmanagaoglu, Mehmet A

    2018-03-23

    We hypothesised that the pressure on the cervix increases with advancing gestation and it may lead to a cervical shortening and cause preterm labour in women with weak pelvic floor muscles. The aim of this prospective study was to measure vaginal resting pressure and pelvic floor muscle strength in the first trimester of pregnancy and to investigate their effects on labour. A study was conducted on the pregnant women with a low risk for preterm birth. The pelvic floor muscle strength and vaginal resting pressure were assessed in 320 pregnant women at their first trimester with a vaginal pressure measurement device. Fifty-two pregnant women were hospitalised for tocolytic therapy because of spontaneous preterm labour. Thirty-two of them (10.2%) had a preterm delivery despite the tocolytic therapy. Both the vaginal resting pressure (p = .009, 95%CI: 0.8; 5.9) and the pelvic floor muscle strength (p = .01, 95%CI: 3.5; 13.1) were significantly lower in the women with a preterm labour. Impact statement What is already known on this subject? The pelvic floor muscles have an essential role in continence and provide support to the pelvic organs. They also have an impact on labour. The pelvic floor muscles should distend to allow the passage of the foetus during labour. The rotation and flexion of the foetal head is due to the pelvic floor resistance. The effect of a vaginal birth on the pelvic floor's function is readily understood. On the other hand, the effect of the pelvic floor muscle function on labour is still controversial. What do the results of this study add? This prospective study showed that there is a negative association between the pelvic floor muscle strength and preterm labour. This is the first clinical study indicating that weak pelvic floor muscles may cause a preterm labour. What are the implications of these findings for clinical practice and/or further research? Pelvic floor physical therapy may be an alternative preventive strategy to reduce

  17. Pelvic X-ray misses out on detecting sacral fractures in the elderly - Importance of CT imaging in blunt pelvic trauma.

    Science.gov (United States)

    Schicho, Andreas; Schmidt, Stefan A; Seeber, Kevin; Olivier, Alain; Richter, Peter H; Gebhard, Florian

    2016-03-01

    Patients aged 75 years and older with blunt pelvic trauma are frequently seen in the ER. The standard diagnostic tool in these patients is the plain a.p.-radiograph of the pelvis. Especially lesions of the posterior pelvic ring are often missed due to e.g. bowel gas projection and enteric overlay. With a retrospective study covering these patients over a 3 year period in our level I trauma centre, we were able to evaluate the rate of missed injuries in the a.p.-radiograph whenever a corresponding CT scan was performed. Age, gender, and accompanying fractures of the pelvic ring were recorded. The intrinsic test characteristics and the performance in the population were calculated according to standard formulas. Thus, 233 consecutive patients with blunt pelvic trauma with both conventional radiographic examination and computed tomography (CT) were included. Thereof, 56 (23%) showed a sacral fracture in the CT scan. Of 233 pelvic X-ray-images taken, 227 showed no sacral fracture. 51 (21.7%) of these were false negative, yielding a sensitivity of just 10.5%. Average age of patients with sacral fractures was 85.1±6.1 years, with 88% being female. Sacral fractures were often accompanied by lesions of the anterior pelvic ring with pubic bone fractures in 75% of sacrum fracture cases. Second most concomitant fractures are found at the acetabulum (23.3%). Plain radiographic imaging is especially likely to miss out fractures of the posterior pelvic ring, which nowadays can be of therapeutic consequence. Besides the physicians experience in the ED, profound knowledge of insensitivity of plain radiographs in finding posterior pelvic ring lesions is crucial for a reliable diagnostic routine. Since the high mortality caused by prolonged immobilisation due to pelvic ring injuries, all fractures should be identified. We therefore provide a diagnostic algorithm for blunt pelvic trauma in the elderly. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. HEMISPHERIC HELICITY TREND FOR SOLAR CYCLE 24

    International Nuclear Information System (INIS)

    Hao Juan; Zhang Mei

    2011-01-01

    Using vector magnetograms obtained with the Spectro-polarimeter (SP) on board Hinode satellite, we studied two helicity parameters (local twist and current helicity) of 64 active regions that occurred in the descending phase of solar cycle 23 and the ascending phase of solar cycle 24. Our analysis gives the following results. (1) The 34 active regions of the solar cycle 24 follow the so-called hemispheric helicity rule, whereas the 30 active regions of the solar cycle 23 do not. (2) When combining all 64 active regions as one sample, they follow the hemispheric helicity sign rule as in most other observations. (3) Despite the so-far most accurate measurement of vector magnetic field given by SP/Hinode, the rule is still weak with large scatters. (4) The data show evidence of different helicity signs between strong and weak fields, confirming previous result from a large sample of ground-based observations. (5) With two example sunspots we show that the helicity parameters change sign from the inner umbra to the outer penumbra, where the sign of penumbra agrees with the sign of the active region as a whole. From these results, we speculate that both the Σ-effect (turbulent convection) and the dynamo have contributed in the generation of helicity, whereas in both cases turbulence in the convection zone has played a significant role.

  19. Surgical reconstruction of pelvic floor descent: anatomic and functional aspects.

    Science.gov (United States)

    Wagenlehner, F M E; Bschleipfer, T; Liedl, B; Gunnemann, A; Petros, P; Weidner, W

    2010-01-01

    The human pelvic floor is a complex structure and pelvic floor dysfunction is seen frequently in females. This review focuses on the surgical reconstruction of the pelvic floor employing recent findings on functional anatomy. A selective literature research was performed by the authors. Pelvic floor activity is regulated by 3 main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor organs, bladder and rectum. A variety of symptoms can derive from pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, fecal incontinence, obstructive bowel disease syndrome and pelvic pain. These symptoms mainly derive, for different reasons, from laxity in the vagina or its supporting ligaments as a result of altered connective tissue. Pelvic floor reconstruction is nowadays driven by the concept that in case of pelvic floor symptoms, restoration of the anatomy will translate into restoration of the physiology and ultimately improve patients' symptoms. The surgical reconstruction of the anatomy is almost exclusively focused on the restoration of the lax pelvic floor ligaments. Exact preoperative identification of the anatomical lesions is necessary to allow for exact anatomical reconstruction with respect to the muscular forces of the pelvic floor. Copyright 2010 S. Karger AG, Basel.

  20. Ion temperature gradient modes in toroidal helical systems

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, T. [Graduate University for Advanced Studies, Toki, Gifu (Japan); Sugama, H.; Kanno, R.; Okamoto, M.

    2000-04-01

    Linear properties of ion temperature gradient (ITG) modes in helical systems are studied. The real frequency, growth rate, and eigenfunction are obtained for both stable and unstable cases by solving a kinetic integral equation with proper analytic continuation performed in the complex frequency plane. Based on the model magnetic configuration for toroidal helical systems like the Large Helical Device (LHD), dependences of the ITG mode properties on various plasma equilibrium parameters are investigated. Particularly, relative effects of {nabla}B-curvature drifts driven by the toroidicity and by the helical ripples are examined in order to compare the ITG modes in helical systems with those in tokamaks. (author)

  1. Ion temperature gradient modes in toroidal helical systems

    International Nuclear Information System (INIS)

    Kuroda, T.; Sugama, H.; Kanno, R.; Okamoto, M.

    2000-04-01

    Linear properties of ion temperature gradient (ITG) modes in helical systems are studied. The real frequency, growth rate, and eigenfunction are obtained for both stable and unstable cases by solving a kinetic integral equation with proper analytic continuation performed in the complex frequency plane. Based on the model magnetic configuration for toroidal helical systems like the Large Helical Device (LHD), dependences of the ITG mode properties on various plasma equilibrium parameters are investigated. Particularly, relative effects of ∇B-curvature drifts driven by the toroidicity and by the helical ripples are examined in order to compare the ITG modes in helical systems with those in tokamaks. (author)

  2. Re-Shielding of Cobalt-60 Teletherapy Rooms for Tomotherapy and Conventional Linear Accelerators using Monte Carlo Simulations

    Science.gov (United States)

    Çeçen, Yiğit; Yazgan, Çağrı

    2017-09-01

    Purpose. Nearly all Cobalt-60 teletherapy machines were removed around the world during the last two decades. The remaining ones are being used for experimental purposes. However, the rooms of these teletherapy machines are valuable because of lack of space in radiotherapy clinics. In order to place a new technology treatment machine in one of these rooms, one should re-shield the room since it was designed only for 1.25 MeV gamma beams on average. Mostly, the vendor of the new machine constructs the new shielding of the room using their experience. However, every radiotherapy room has different surrounding work areas and it would be wise to shield the room considering these special conditions. Also, the shield design goal of the clinic may be much lower than the International Atomic Energy Agency (IAEA) or the local association accepts. The study shows re-shielding of a Cobalt-60 room, specific to the clinic, using Monte Carlo simulations. Materials & Methods: First, a 6 MV Tomotherapy machine, then a 10 MV conventional linear accelerator (LINAC) was placed inside the Cobalt-60 teletherapy room. The photon flux outside the room was simulated using Monte Carlo N-Particle (MCNP6.1) code before and after re-shielding. For the Tomotherapy simulation, flux distributions around the machine were obtained from the vendor and implemented as the source of the model. The LINAC model was more generic with the 10 MeV electron source, the tungsten target, first and secondary collimators. The aim of the model was to obtain the maximum (40x40 cm2) open field at the isocenter. Two different simulations were carried out for gantry angles 90o and 270o. The LINAC was placed in the room such that the primary walls were A' (Gantry 270o) and C' (Gantry 90o) (figure 1). The second part of the study was to model the re-shielding of the room for Tomotherapy and for the conventional LINAC, separately. The aim was to investigate the recommended shielding by the vendors. Left side of the room

  3. [Clinical characteristics and pathophysiology of pelvic pain in women].

    Science.gov (United States)

    Wesselmann, U

    2002-12-01

    Chronic pelvic pain is a common and debilitating problem that can significantly impair the quality of life of a woman. Patients with chronic pelvic pain are usually evaluated and treated by gynecologists, gastroenterologists, urologists, and internists. Although these patients seek medical care because they are looking for help to alleviate their pelvic discomfort and pain, in many cases the only focus is on finding and possibly treating the underlying pelvic disease.However, often the examination and work-up remain unrevealing and no specific cause of the pain can be identified. At this point patients are frequently told, that no etiology for their chronic pain syndrome can be found and that nothing can be done. In these cases it is important to recognize that pain is not only a symptom of pelvic disease, but that the patient is suffering from a chronic pelvic pain syndrome. Knowledge of the clinical characteristics of visceral pain will guide the health care provider in making a diagnosis of chronic pelvic pain and in sorting it out from the lump diagnosis of idiopathic pain. Once the diagnosis of chronic pelvic pain is made, treatment should be directed towards symptomatic pain management.This conceptualization of chronic pelvic pain is very important, because chronic pelvic pain is a treatable condition! Effective treatment modalities are available to lessen the impact of pain and offer reasonable expectations of an improved functional status.

  4. ICRF heating on helical devices

    International Nuclear Information System (INIS)

    Rasmussen, D.A.; Lyon, J.F.; Hoffman, D.J.; Murakami, M.; England, A.C.; Wilgen, J.B.; Jaeger, E.F.; Wang, C.; Batchelor, D.B.

    1995-01-01

    Ion cyclotron range of frequency (ICRF) heating is currently in use on CHS and W7-AS and is a major element of the heating planned for steady state helical devices. In helical devices, the lack of a toroidal current eliminates both disruptions and the need for ICRF current drive, simplifying the design of antenna structures as compared to tokamak applications. However the survivability of plasma facing components and steady state cooling issues are directly applicable to tokamak devices. Results from LHD steady state experiments should be available on a time scale to strongly influence the next generation of steady state tokamak experiments. The helical plasma geometry provides challenges not faced with tokamak ICRF heating, including the potential for enhanced fast ion losses, impurity accumulation, limited access for antenna structures, and open magnetic field lines in the plasma edge. The present results and near term plans provide the basis for steady state ICRF heating of larger helical devices. An approach which includes direct electron, mode conversion, ion minority and ion Bernstein wave heating addresses these issues

  5. ICRF heating on helical devices

    International Nuclear Information System (INIS)

    Rasmussen, D.A.; Lyon, J.F.; Hoffman, D.J.

    1995-01-01

    Ion cyclotron range of frequency (ICRF) heating is currently in use on CHS and W7AS and is a major element of the heating planned for steady state helical devices. In helical devices, the lack of a toroidal current eliminates both disruptions and the need for ICRF current drive, simplifying the design of antenna structures as compared to tokamak applications. However the survivability of plasma facing components and steady state cooling issues are directly applicable to tokamak devices. Results from LHD steady state experiments should be available on a time scale to strongly influence the next generation of steady state tokamak experiments. The helical plasma geometry provides challenges not faced with tokamak ICRF heating, including the potential for enhanced fast ion losses, impurity accumulation, limited access for antenna structures, and open magnetic field lines in the plasma edge. The present results and near term plans provide the basis for steady state ICRF heating of larger helical devices. An approach which includes direct electron, mode conversion, ion minority and ion Bernstein wave heating addresses these issues

  6. Generalized helicity and Beltrami fields

    International Nuclear Information System (INIS)

    Buniy, Roman V.; Kephart, Thomas W.

    2014-01-01

    We propose covariant and non-abelian generalizations of the magnetic helicity and Beltrami equation. The gauge invariance, variational principle, conserved current, energy–momentum tensor and choice of boundary conditions elucidate the subject. In particular, we prove that any extremal of the Yang–Mills action functional 1/4 ∫ Ω trF μν F μν d 4 x subject to the local constraint ε μναβ trF μν F αβ =0 satisfies the covariant non-abelian Beltrami equation. -- Highlights: •We introduce the covariant non-abelian helicity and Beltrami equation. •The Yang–Mills action and instanton term constraint lead to the Beltrami equation. •Solutions of the Beltrami equation conserve helicity

  7. The 12-month effects of structured lifestyle advice and pelvic floor muscle training for pelvic organ prolapse

    DEFF Research Database (Denmark)

    Due, Ulla; Brostrøm, Søren; Lose, Gunnar

    2016-01-01

    INTRODUCTION: We evaluated the 12-month effects of adding pelvic floor muscle training to a lifestyle advice program in women with symptomatic pelvic organ prolapse stage II-III and the number of women who had sought further treatment. MATERIAL AND METHODS: This study was a 12-month follow up...... of a randomized controlled trial comparing a structured lifestyle advice program alone (lifestyle group) or in combination with pelvic floor muscle training (training and lifestyle group). Both programs consisted of six separate group sessions within 12 weeks. RESULTS: Data were available from 83 (76%) of the 109...... surgery. More severe anterior prolapse and more bladder symptoms at the 3-month follow up were significantly associated with having sought further treatment in both groups. CONCLUSIONS: At 12-month follow up, the effects of adding pelvic floor muscle training to a structured lifestyle advice program were...

  8. Efficacy of pelvic floor muscle training and hypopressive exercises for treating pelvic organ prolapse in women: randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Bruno Teixeira Bernardes

    Full Text Available CONTEXT AND OBJECTIVE: Previous studies have shown that women with pelvic floor dysfunctions present decreased cross-sectional area (CSA of the levator ani muscle. One way to assess the effects of training programs is to measure the CSA of the muscle, using ultrasonography. The aim here was to evaluate the efficacy of pelvic floor muscle training and hypopressive exercises for increasing the CSA of the levator ani muscle in women with pelvic organ prolapse. DESIGN AND SETTING: Prospective randomized controlled trial at the Urogynecology outpatient clinic of Universidade Federal de São Paulo. METHODS: Fifty-eight women with stage II pelvic organ prolapse were divided into three groups for physiotherapy: a pelvic floor muscle training group (GI; a hypopressive exercise group (GII; and a control group (GIII. The patients underwent transperineal ultrasonographic evaluation using a transducer of frequency 4-9 MHz. The (CSA of the levator ani muscle was measured before physiotherapy and after 12 weeks of treatment. RESULTS: The groups were homogeneous regarding age, number of pregnancies, number of vaginal deliveries, body mass index and hormonal status. Statistically significant differences in CSA were found in GI and GII from before to after the treatment (P < 0.001, but not in relation to GIII (P = 0.816. CONCLUSIONS: The CSA of the levator ani muscle increased significantly with physiotherapy among the women with pelvic organ prolapse. Pelvic floor muscle training and hypopressive exercises produced similar improvements in the CSA of the levator ani muscle.

  9. Ultrasound guided transrectal catheter drainage of pelvic collections.

    Science.gov (United States)

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  10. Helical-D pinch

    International Nuclear Information System (INIS)

    Schaffer, M.J.

    1997-08-01

    A stabilized pinch configuration is described, consisting of a D-shaped plasma cross section wrapped tightly around a guiding axis. The open-quotes helical-Dclose quotes geometry produces a very large axial (toroidal) transform of magnetic line direction that reverses the pitch of the magnetic lines without the need of azimuthal (poloidal) plasma current. Thus, there is no need of a open-quotes dynamoclose quotes process and its associated fluctuations. The resulting configuration has the high magnetic shear and pitch reversal of the reversed field pinch (RFP). (Pitch = P = qR, where R = major radius). A helical-D pinch might demonstrate good confinement at q << 1

  11. CT in the evaluation of pelvic trauma

    International Nuclear Information System (INIS)

    Federle, M.P.

    1986-01-01

    Pelvic fractures from motor vehicle accidents are a cause of substantial morbidity and permanent disability, and are the third leading cause of death following blunt trauma. Associated extremity fractures are common, and injury to abdominal and pelvic viscera may occur. Difficulty in establishing the source of hemorrhage may be encountered, especially since pelvic fractures with extraperitoneal bleeding may result in intraperitoneal bleeding through torn fascial planes. The difficulty in properly diagnosing and managing complex fractures of the pelvis and acetabulum is well documented. Prognosis is influenced by the type and extent of pelvic fracture and associated soft tissue injuries. Computed tomography (CT) has proved to be a valuable tool in evaluation of these complex and life-threatening injuries

  12. Biomimetic matrices for pelvic floor repair

    NARCIS (Netherlands)

    Vashaghian, M.

    2017-01-01

    Pelvic organ prolapsed (POP) is a dysfunctional disease in female pelvic floor that affects a lot of women worldwide, and reduces their quality of life. Currently, trans-vaginal knitted polypropylene meshes are used as secondary treatment, for anatomical correction of the dysfunctional tissues.

  13. [Modern aspects of surgical treatment of locally advanced pelvic cancer].

    Science.gov (United States)

    Solovyov, I A; Vasilchenko, M V; Lychev, A B; Ambartsumyan, S V; Alekseev, V V

    2015-09-01

    The aim of investigation is to improve surgical treatment of patients with locally advanced pelvic cancer. The basis of investigation is 186 patients with locally advanced pelvic cancer. The average age of patients is 65.2 ± 5.2 years (from 43.7 to 88.4 years). Among them are 112 women and 74 men. In the period from 2007 to 2015 they were carried out combined (101 patients) and expanded (85 patients) surgical intervention in the department of naval surgery of the Military medical academy after S.M.Kirov. Pelvic evisceration was performed in 63 cases. Both patients were performed isolated vascular hyperthermic chemical pelvic perfusion. Indications for plastic surgery of peritoneum pelvic were: total infralitoral pelvic evisceration (9 patients), dorsal infralitoral pelvic evisceration (11 cases) and expanded abdominoperineal rectum extirpation (34 patients). Plastic surgery with autogenouse tissues was performed to 43 patients, with reticulate explants--to 11 patients. The rate of postoperative complications was 40.2%. The rate of postoperative lethality was 8%. Expanded and combined operations of pelvic at patients with locally advanced cancer without absolute contra-indications can be performed irrespective of age. Plastic surgery of peritoneum pelvic after total and dorsal infralitoral pelvic evisceration and expanded abdominoperineal rectum extirpation indicated in all cases. The easiest method is plastic surgery with greater omentum or peritoneum pelvic. Plastic surgery with reticulate explants is performed when autoplastic is impossible.

  14. Employing helicity amplitudes for resummation in SCET

    International Nuclear Information System (INIS)

    Moult, Ian; Stewart, Iain W.; Tackmann, Frank J.; Waalewijn, Wouter J.; Nikhef, Amsterdam

    2016-05-01

    Helicity amplitudes are the fundamental ingredients of many QCD calculations for multi-leg processes. We describe how these can seamlessly be combined with resummation in Soft-Collinear Effective Theory (SCET), by constructing a helicity operator basis for which the Wilson coefficients are directly given in terms of color-ordered helicity amplitudes. This basis is crossing symmetric and has simple transformation properties under discrete symmetries.

  15. MHD stability analysis of helical system plasmas

    International Nuclear Information System (INIS)

    Nakamura, Yuji

    2000-01-01

    Several topics of the MHD stability studies in helical system plasmas are reviewed with respect to the linear and ideal modes mainly. Difference of the method of the MHD stability analysis in helical system plasmas from that in tokamak plasmas is emphasized. Lack of the cyclic (symmetric) coordinate makes an analysis more difficult. Recent topic about TAE modes in a helical system is also described briefly. (author)

  16. Laparoendoscopic single site in pelvic surgery

    Science.gov (United States)

    Sanchez-Salas, Rafael; Clavijo, Rafael; Barret, Eric; Sotelo, Rene

    2012-01-01

    Laparoendoscopic single site (LESS) has recently gained momentum as feasible techniques for minimal access surgery. Our aim is to describe the current status of laparoendoscopic single site (LESS) in pelvic surgery. A comprehensive revision of the literature in LESS pelvic surgery was performed. References for this manuscript were obtained by performing a review of the available literature in PubMed from 01-01-01 to 30-11-11. References outside the search period were obtained selected manuscript΄s bibliography. Search terms included: pelvic anatomy, less in gynecology, single port colectomy, urological less, single port, single site, NOTES, LESS and single incision. 314 manuscripts were initially identified. Out of these, 46 manuscripts were selected based in their pelvic anatomy or surgical content; including experimental experience, clinical series and literature reviews. LESS drastically limit the surgeon's ability to perform in the operative field and the latter becomes hardened by the lack of space in anatomical location like the pelvis. Potential advantages of LESS are gained with the understanding that the surgical procedure is more technically challenging. Pelvic surgical procedures related to colorectal surgery, gynecology and urology have been performed with LESS technique and information available is mostly represented by case reports and short case series. Comparative series remain few. LESS pelvic surgery remain in its very beginning and due to the very specific anatomical conditions further development of LESS surgery in the mentioned area can be clearly be facilitated by using robotic technology. Standardization ad reproducibility of techniques are mandatory to further develop LESS in the surgical arena.. PMID:22557719

  17. Laparoendoscopic single site in pelvic surgery

    Directory of Open Access Journals (Sweden)

    Rafael Sanchez-Salas

    2012-01-01

    Full Text Available Laparoendoscopic single site (LESS has recently gained momentum as feasible techniques for minimal access surgery. Our aim is to describe the current status of laparoendoscopic single site (LESS in pelvic surgery. A comprehensive revision of the literature in LESS pelvic surgery was performed. References for this manuscript were obtained by performing a review of the available literature in PubMed from 01-01-01 to 30-11-11. References outside the search period were obtained selected manuscript΄s bibliography. Search terms included: pelvic anatomy, less in gynecology, single port colectomy, urological less, single port, single site, NOTES, LESS and single incision. 314 manuscripts were initially identified. Out of these, 46 manuscripts were selected based in their pelvic anatomy or surgical content; including experimental experience, clinical series and literature reviews. LESS drastically limit the surgeon′s ability to perform in the operative field and the latter becomes hardened by the lack of space in anatomical location like the pelvis. Potential advantages of LESS are gained with the understanding that the surgical procedure is more technically challenging. Pelvic surgical procedures related to colorectal surgery, gynecology and urology have been performed with LESS technique and information available is mostly represented by case reports and short case series. Comparative series remain few. LESS pelvic surgery remain in its very beginning and due to the very specific anatomical conditions further development of LESS surgery in the mentioned area can be clearly be facilitated by using robotic technology. Standardization ad reproducibility of techniques are mandatory to further develop LESS in the surgical arena..

  18. Pelvic congestion syndrome masquerading as osteoarthritis of the hip

    Directory of Open Access Journals (Sweden)

    Scott J Dos Santos

    2016-12-01

    Full Text Available Objectives: Pelvic congestion syndrome (PCS is associated with pelvic vein reflux (PVR, occasionally secondary to venous compression. Its symptoms, usually intra-pelvic, are alleviated following the abolition of this reflux by pelvic vein embolisation (PVE. The objective of this report is to present two cases of left hip pain, erroneously diagnosed as osteoarthritis, which disappeared after successful PVE and abolition of PVR. Methods: Two females presented with lower limb varicose veins, and also had a history of left-sided hip pain. Both had previously been investigated for the hip pain and diagnosed as osteoarthritis despite minimal arthritic changes on pelvic X-rays. During investigation for lower limb varicose veins, both showed a pelvic origin for their leg veins and hence underwent transvaginal duplex ultrasound. This revealed PVR, and PVE was planned in both patients. Results: Both patients underwent PVE and reported ‘miraculous’ resolution of left hip pain and also PCS symptoms including pelvic pain, irritable bowel issues and the disappearance of pelvic dragging, with almost immediate disappearance of vulval and vaginal varicosities. One patient also noted reduced clitoral sensitivity. Conclusion: Manifestations of PCS may vary in terms of intra- or extra-pelvic signs. PCS and PVR should be considered in the differential diagnosis of patients with arthritic symptoms in the hip without evident radiographic evidence.

  19. Pelvic incidence variation among individuals: functional influence versus genetic determinism.

    Science.gov (United States)

    Chen, Hong-Fang; Zhao, Chang-Qing

    2018-03-20

    Pelvic incidence has become one of the most important sagittal parameters in spinal surgery. Despite its great importance, pelvic incidence can vary from 33° to 85° in the normal population. The reasons for this great variability in pelvic incidence remain unexplored. The objective of this article is to present some possible interpretations for the great variability in pelvic incidence under both normal and pathological conditions and to further understand the determinants of pelvic incidence from the perspective of the functional requirements for bipedalism and genetic backgrounds via a literature review. We postulate that both pelvic incidence and pelvic morphology may be genetically predetermined, and a great variability in pelvic incidence may already exist even before birth. This great variability may also serve as a further reminder that the sagittal profile, bipedal locomotion mode, and genetic background of every individual are unique and specific, and clinicians should avoid making universally applying broad generalizations of pelvic incidence. Although PI is an important parameter and there are many theories behind its variability, we still do not have clear mechanistic answers.

  20. [Ultrasonography in acute pelvic pain].

    Science.gov (United States)

    Kupesić, Sanja; Aksamija, Alenka; Vucić, Niksa; Tripalo, Ana; Kurjak, Asim

    2002-01-01

    Acute pelvic pain may be the manifestation of various gynecologic and non-gynecologic disorders from less alarming rupture of the follicular cyst to life threatening conditions such as rupture of ectopic pregnancy or perforation of inflamed appendix. In order to construct an algorithm for differential diagnosis we divide acute pelvic pain into gynecologic and non-gynecologic etiology, which is than subdivided into gastrointestinal and urinary causes. Appendicitis is the most common surgical emergency and should always be considered in differential diagnosis if appendix has not been removed. Apart of clinical examination and laboratory tests, an ultrasound examination is sensitive up to 90% and specific up to 95% if graded compression technique is used. Still it is user-depended and requires considerable experience in order to perform it reliably. Meckel's diverticulitis, acute terminal ileitis, mesenteric lymphadenitis and functional bowel disease are conditions that should be differentiated from other causes of low abdominal pain by clinical presentation, laboratory and imaging tests. Dilatation of renal pelvis and ureter are typical signs of obstructive uropathy and may be efficiently detected by ultrasound. Additional thinning of renal parenchyma suggests long-term obstructive uropathy. Ruptured ectopic pregnancy, salpingitis and hemorrhagic ovarian cysts are three most commonly diagnosed gynecologic conditions presenting as an acute abdomen. Degenerating leiomyomas and adnexal torsion occur less frequently. For better systematization, gynecologic causes of acute pelvic pain could be divided into conditions with negative pregnancy test and conditions with positive pregnancy test. Pelvic inflammatory disease may be ultrasonically presented with numerous signs such as thickening of the tubal wall, incomplete septa within the dilated tube, demonstration of hyperechoic mural nodules, free fluid in the "cul-de-sac" etc. Color Doppler ultrasound contributes to more

  1. Retroperitoneal and pelvic fibromatosis

    International Nuclear Information System (INIS)

    Lopez de Lacalle, J. M.; Garmendia, G.; Laso, C.; Galardi, A.

    1998-01-01

    We present a case of retroperitoneal and pelvic fibromatosis in a 17-year-old boy who came to the emergency room with sudden onset acute abdominal pain. The initial radiological examination (plain X-ray and ultrasound) disclosed only minimal right hydronephrosis. Subsequent computed tomography revealed the presence of a solid retroperitoneal and pelvic mass involving right ureter and secondary right hydronephrosis. We stress its presentation in the form of acute abdominal pain with initial radiological signs suggestive of a primarily urological disorder. (Author) 8 refs

  2. Validation of an elastic registration technique to estimate anatomical lung modification in Non-Small-Cell Lung Cancer Tomotherapy

    International Nuclear Information System (INIS)

    Faggiano, Elena; Cattaneo, Giovanni M; Ciavarro, Cristina; Dell'Oca, Italo; Persano, Diego; Calandrino, Riccardo; Rizzo, Giovanna

    2011-01-01

    The study of lung parenchyma anatomical modification is useful to estimate dose discrepancies during the radiation treatment of Non-Small-Cell Lung Cancer (NSCLC) patients. We propose and validate a method, based on free-form deformation and mutual information, to elastically register planning kVCT with daily MVCT images, to estimate lung parenchyma modification during Tomotherapy. We analyzed 15 registrations between the planning kVCT and 3 MVCT images for each of the 5 NSCLC patients. Image registration accuracy was evaluated by visual inspection and, quantitatively, by Correlation Coefficients (CC) and Target Registration Errors (TRE). Finally, a lung volume correspondence analysis was performed to specifically evaluate registration accuracy in lungs. Results showed that elastic registration was always satisfactory, both qualitatively and quantitatively: TRE after elastic registration (average value of 3.6 mm) remained comparable and often smaller than voxel resolution. Lung volume variations were well estimated by elastic registration (average volume and centroid errors of 1.78% and 0.87 mm, respectively). Our results demonstrate that this method is able to estimate lung deformations in thorax MVCT, with an accuracy within 3.6 mm comparable or smaller than the voxel dimension of the kVCT and MVCT images. It could be used to estimate lung parenchyma dose variations in thoracic Tomotherapy

  3. Generalized helicity and Beltrami fields

    Energy Technology Data Exchange (ETDEWEB)

    Buniy, Roman V., E-mail: roman.buniy@gmail.com [Schmid College of Science, Chapman University, Orange, CA 92866 (United States); Isaac Newton Institute, University of Cambridge, Cambridge, CB3 0EH (United Kingdom); Kephart, Thomas W., E-mail: tom.kephart@gmail.com [Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37235 (United States); Isaac Newton Institute, University of Cambridge, Cambridge, CB3 0EH (United Kingdom)

    2014-05-15

    We propose covariant and non-abelian generalizations of the magnetic helicity and Beltrami equation. The gauge invariance, variational principle, conserved current, energy–momentum tensor and choice of boundary conditions elucidate the subject. In particular, we prove that any extremal of the Yang–Mills action functional 1/4 ∫{sub Ω}trF{sub μν}F{sup μν}d{sup 4}x subject to the local constraint ε{sup μναβ}trF{sub μν}F{sub αβ}=0 satisfies the covariant non-abelian Beltrami equation. -- Highlights: •We introduce the covariant non-abelian helicity and Beltrami equation. •The Yang–Mills action and instanton term constraint lead to the Beltrami equation. •Solutions of the Beltrami equation conserve helicity.

  4. Comparison between dynamic cystocolpoproctography and dynamic pelvic floor MRI: pros and cons: which is the "functional" examination for anorectal and pelvic floor dysfunction?

    Science.gov (United States)

    Maglinte, Dean D T; Hale, Douglass S; Sandrasegaran, Kumar

    2013-10-01

    "Functional" imaging of anorectal and pelvic floor dysfunction has assumed an important role in the diagnosis and management of these disorders. Although defecography has been widely practiced for decades to evaluate the dynamics of rectal emptying, debate concerning its clinical relevance, how it should be done and interpreted continues. Due to the recognition of the association of defecatory disorders with pelvic organ prolapse in women, the need to evaluate the pelvic floor as a unit has arisen. To meet this need, defecography has been extended to include not only evaluation of defecation disorders but also the rest of the pelvic floor by opacifying the small bowel, vagina, and the urinary bladder. The term "dynamic cystocolpoproctography" (DCP) has been appropriately applied to this examination. Rectal emptying performed with DCP provides the maximum stress to the pelvic floor resulting in complete levator ani relaxation. In addition to diagnosing defecatory disorders, this method of examination demonstrates maximum pelvic organ descent and provides organ-specific quantification of organ prolapse, information that is only inferred by means of physical examination. It has been found to be of clinical value in patients with defecation disorders and the diagnosis of associated prolapse in other compartments that are frequently unrecognized by history taking and the limitations of physical examination. Pelvic floor anatomy is complex and DCP does not show the anatomical details pelvic magnetic resonance imaging (MRI) provides. Technical advances allowing acquisition of dynamic rapid MRI sequences has been applied to pelvic floor imaging. Early reports have shown that pelvic MRI may be a useful tool in pre-operative planning of these disorders and may lead to a change in surgical therapy. Predictions of hypothetical increase cancer incidence and deaths in patients exposed to radiation, the emergence of pelvic floor MRI in addition to questions relating to the

  5. Pelvic Surgical Site Infections in Gynecologic Surgery

    Directory of Open Access Journals (Sweden)

    Mark P. Lachiewicz

    2015-01-01

    Full Text Available The development of surgical site infection (SSI remains the most common complication of gynecologic surgical procedures and results in significant patient morbidity. Gynecologic procedures pose a unique challenge in that potential pathogenic microorganisms from the skin or vagina and endocervix may migrate to operative sites and can result in vaginal cuff cellulitis, pelvic cellulitis, and pelvic abscesses. Multiple host and surgical risk factors have been identified as risks that increase infectious sequelae after pelvic surgery. This paper will review these risk factors as many are modifiable and care should be taken to address such factors in order to decrease the chance of infection. We will also review the definitions, microbiology, pathogenesis, diagnosis, and management of pelvic SSIs after gynecologic surgery.

  6. CURRENT AND KINETIC HELICITY OF LONG-LIVED ACTIVITY COMPLEXES

    International Nuclear Information System (INIS)

    Komm, Rudolf; Gosain, Sanjay

    2015-01-01

    We study long-lived activity complexes and their current helicity at the solar surface and their kinetic helicity below the surface. The current helicity has been determined from synoptic vector magnetograms from the NSO/SOLIS facility, and the kinetic helicity of subsurface flows has been determined with ring-diagram analysis applied to full-disk Dopplergrams from NSO/GONG and SDO/HMI. Current and kinetic helicity of activity complexes follow the hemispheric helicity rule with mainly positive values (78%; 78%, respectively, with a 95% confidence level of 31%) in the southern hemisphere and negative ones (80%; 93%, respectively, with a 95% confidence level of 22% and 14%, respectively) in the northern hemisphere. The locations with the dominant sign of kinetic helicity derived from Global Oscillation Network Group (GONG) and SDO/HMI data are more organized than those of the secondary sign even if they are not part of an activity complex, while locations with the secondary sign are more fragmented. This is the case for both hemispheres even for the northern one where it is not as obvious visually due to the large amount of magnetic activity present as compared to the southern hemisphere. The current helicity shows a similar behavior. The dominant sign of current helicity is the same as that of kinetic helicity for the majority of the activity complexes (83% with a 95% confidence level of 15%). During the 24 Carrington rotations analyzed here, there is at least one longitude in each hemisphere where activity complexes occur repeatedly throughout the epoch. These ''active'' longitudes are identifiable as locations of strong current and kinetic helicity of the same sign

  7. Comparison of changes in the mobility of the pelvic floor muscle on during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction.

    Science.gov (United States)

    Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho

    2016-01-01

    [Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility was evaluated as the distance from the bladder base using ultrasound. [Results] According to exercise method, bridge exercise and abdominal curl-ups led to significantly different pelvic floor mobility. The pelvic floor muscle was elevated during the abdominal drawing-in maneuver and descended during maximal expiration. Finally, pelvic floor muscle mobility was greater during abdominal curl-up than during the bridge exercise. [Conclusion] According to these results, the abdominal drawing-in maneuver induced pelvic floor muscle contraction, and pelvic floor muscle contraction was greater during the abdominal curl-up than during the bridge exercise.

  8. Female Pelvic Vein Embolization: Indications, Techniques, and Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Anthony James, E-mail: consultant@radiologist.co.uk [The Imaging Clinic (United Kingdom)

    2015-08-15

    Until recently, the main indication for pelvic vein embolization (PVE) in women was to treat pelvic venous congestion syndrome (PVC) but increasingly, patients with refluxing pelvic veins associated with leg varicosities are also being treated. A more unusual reason for PVE is to treat pelvic venous malformations, although such lesions may be treated with sclerotherapy alone. Embolotherapy for treating PVC has been performed for many years with several published studies included in this review, whilst an emerging indication for PVE is to treat lower limb varicosities associated with pelvic vein reflux. Neither group, however, has been subjected to an adequate randomized, controlled trial. Consequently, some of the information presented in this review should be considered anecdotal (level III evidence) at this stage, and a satisfactory ‘proof’ of clinical efficacy remains deficient until higher-level evidence is presented. Furthermore, a wide range of techniques not accepted by all are used, and some standardization will be required based on future mandatory prospective studies. Large studies have also clearly shown an unacceptably high recurrence rate of leg varicose veins following venous surgery. Furthermore, minimally or non-invasive imaging is now revealing that there is a refluxing pelvic venous source in a significant percentage of women with de novo leg varicose veins, and many more with recurrent varicosities. Considering that just over half the world’s population is female and a significant number of women not only have pelvic venous reflux, but also have associated leg varicosities, minimally invasive treatment of pelvic venous incompetence will become a common procedure.

  9. Female Pelvic Vein Embolization: Indications, Techniques, and Outcomes

    International Nuclear Information System (INIS)

    Lopez, Anthony James

    2015-01-01

    Until recently, the main indication for pelvic vein embolization (PVE) in women was to treat pelvic venous congestion syndrome (PVC) but increasingly, patients with refluxing pelvic veins associated with leg varicosities are also being treated. A more unusual reason for PVE is to treat pelvic venous malformations, although such lesions may be treated with sclerotherapy alone. Embolotherapy for treating PVC has been performed for many years with several published studies included in this review, whilst an emerging indication for PVE is to treat lower limb varicosities associated with pelvic vein reflux. Neither group, however, has been subjected to an adequate randomized, controlled trial. Consequently, some of the information presented in this review should be considered anecdotal (level III evidence) at this stage, and a satisfactory ‘proof’ of clinical efficacy remains deficient until higher-level evidence is presented. Furthermore, a wide range of techniques not accepted by all are used, and some standardization will be required based on future mandatory prospective studies. Large studies have also clearly shown an unacceptably high recurrence rate of leg varicose veins following venous surgery. Furthermore, minimally or non-invasive imaging is now revealing that there is a refluxing pelvic venous source in a significant percentage of women with de novo leg varicose veins, and many more with recurrent varicosities. Considering that just over half the world’s population is female and a significant number of women not only have pelvic venous reflux, but also have associated leg varicosities, minimally invasive treatment of pelvic venous incompetence will become a common procedure

  10. Motor cortical representation of the pelvic floor muscles.

    Science.gov (United States)

    Schrum, A; Wolff, S; van der Horst, C; Kuhtz-Buschbeck, J P

    2011-07-01

    Pelvic floor muscle training involves rhythmical voluntary contractions of the external urethral sphincter and ancillary pelvic floor muscles. The representation of these muscles in the motor cortex has not been located precisely and unambiguously. We used functional magnetic resonance imaging to determine brain activity during slow and fast pelvic floor contractions. Cerebral responses were recorded in 17 healthy male volunteers, 21 to 47 years old, with normal bladder control. Functional magnetic resonance imaging was performed during metronome paced slow (0.25 Hertz) and fast (0.7 Hertz) contractions of the pelvic floor that mimicked the interruption of voiding. To study the somatotopy of the cortical representations, flexion-extension movements of the right toes were performed as a control task. Functional magnetic resonance imaging during pelvic floor contractions detected activity of the supplementary motor area in the medial wall and of the midcingulate cortex, insula, posterior parietal cortex, putamen, thalamus, cerebellar vermis and upper ventral pons. There were no significant differences in activation between slow and fast contractions. Toe movements involved significantly stronger activity of the paracentral lobule (ie the medial primary motor cortex) than did the pelvic floor contractions. Otherwise the areas active during pelvic floor and leg muscle contractions overlapped considerably. The motor cortical representation of pelvic floor muscles is located mostly in the supplementary motor area. It extends further ventrally and anteriorly than the representation of distal leg muscles. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Pelvic floor spasm as a cause of voiding dysfunction.

    Science.gov (United States)

    Kuo, Tricia L C; Ng, L G; Chapple, Christopher R

    2015-07-01

    Pelvic floor disorders can present with lower urinary tract symptoms, bowel, sexual dysfunction, and/or pain. Symptoms of pelvic muscle spasm (nonrelaxing pelvic floor or hypertonicity) vary and can be difficult to recognize. This makes diagnosis and management of these disorders challenging. In this article, we review the current evidence on pelvic floor spasm and its association with voiding dysfunction. To distinguish between the different causes of voiding dysfunction, a video urodynamics study and/or electromyography is often required. Conservative measures include patient education, behavioral modifications, lifestyle changes, and pelvic floor rehabilitation/physical therapy. Disease-specific pelvic pain and pain from pelvic floor spasm needs to be differentiated and treated specifically. Trigger point massage and injections relieves pain in some patients. Botulinum toxin A, sacral neuromodulation, and acupuncture has been reported in the management of patients with refractory symptoms. Pelvic floor spasm and associated voiding problems are heterogeneous in their pathogenesis and are therefore often underrecognized and undertreated; it is therefore essential that a therapeutic strategy needs to be personalized to the individual patient's requirements. Therefore, careful evaluation and assessment of individuals using a multidisciplinary team approach including a trained physical therapist/nurse clinician is essential in the management of these patients.

  12. [Establishement for regional pelvic trauma database in Hunan Province].

    Science.gov (United States)

    Cheng, Liang; Zhu, Yong; Long, Haitao; Yang, Junxiao; Sun, Buhua; Li, Kanghua

    2017-04-28

    To establish a database for pelvic trauma in Hunan Province, and to start the work of multicenter pelvic trauma registry.
 Methods: To establish the database, literatures relevant to pelvic trauma were screened, the experiences from the established trauma database in China and abroad were learned, and the actual situations for pelvic trauma rescue in Hunan Province were considered. The database for pelvic trauma was established based on the PostgreSQL and the advanced programming language Java 1.6.
 Results: The complex procedure for pelvic trauma rescue was described structurally. The contents for the database included general patient information, injurious condition, prehospital rescue, conditions in admission, treatment in hospital, status on discharge, diagnosis, classification, complication, trauma scoring and therapeutic effect. The database can be accessed through the internet by browser/servicer. The functions for the database include patient information management, data export, history query, progress report, video-image management and personal information management.
 Conclusion: The database with whole life cycle pelvic trauma is successfully established for the first time in China. It is scientific, functional, practical, and user-friendly.

  13. 38 CFR 4.67 - Pelvic bones.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Pelvic bones. 4.67 Section 4.67 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.67 Pelvic bones. The variability of residuals...

  14. Helical modes generate antimagnetic rotational spectra in nuclei

    Science.gov (United States)

    Malik, Sham S.

    2018-03-01

    A systematic analysis of the antimagnetic rotation band using r -helicity formalism is carried out for the first time. The observed octupole correlation in a nucleus is likely to play a role in establishing the antimagnetic spectrum. Such octupole correlations are explained within the helical orbits. In a rotating field, two identical fermions (generally protons) with paired spins generate these helical orbits in such a way that its positive (i.e., up) spin along the axis of quantization refers to one helicity (right-handedness) while negative (down) spin along the same quantization-axis decides another helicity (left-handedness). Since the helicity remains invariant under rotation, therefore, the quantum state of a fermion is represented by definite angular momentum and helicity. These helicity represented states support a pear-shaped structure of a rotating system having z axis as the symmetry axis. A combined operation of parity, time-reversal, and signature symmetries ensures an absence of one of the signature partner band from the observed antimagnetic spectrum. This formalism has also been tested for the recently observed negative parity Δ I =2 antimagnetic spectrum in odd-A 101Pd nucleus and explains nicely its energy spectrum as well as the B (E 2 ) values. Further, this formalism is found to be fully consistent with twin-shears mechanism popularly known for such type of rotational bands. It also provides significant clue for extending these experiments in various mass regions spread over the nuclear chart.

  15. MR appearance of pelvic hemangiopericytoma

    International Nuclear Information System (INIS)

    Kehagias, D.; Gouliamos, A.; Vlahos, L.

    1999-01-01

    A case of pelvic hemangiopericytoma in a 59-year-old woman is reported. The MR imaging features are presented. The tumor was unresectable and the patient received postoperative irradiation of 4200 cGy on the pelvis. One year after diagnosis, metastasis to a lumbar vertebra was discovered and additional irradiation of 3900 cGy was applied. One year later, CT showed control of the pelvic tumor and its metastasis. (orig.) (orig.)

  16. MAGNETIC HELICITY FLUX IN THE PRESENCE OF SHEAR

    International Nuclear Information System (INIS)

    Hubbard, Alexander; Brandenburg, Axel

    2011-01-01

    Magnetic helicity has risen to be a major player in dynamo theory, with the helicity of the small-scale field being linked to the dynamo saturation process for the large-scale field. It is a nearly conserved quantity, which allows its evolution equation to be written in terms of production and flux terms. The flux term can be decomposed in a variety of fashions. One particular contribution that has been expected to play a significant role in dynamos in the presence of mean shear was isolated by Vishniac and Cho. Magnetic helicity fluxes are explicitly gauge dependent however, and the correlations that have come to be called the Vishniac-Cho flux were determined in the Coulomb gauge, which turns out to be fraught with complications in shearing systems. While the fluxes of small-scale helicity are explicitly gauge dependent, their divergences can be gauge independent. We use this property to investigate magnetic helicity fluxes of the small-scale field through direct numerical simulations in a shearing-box system and find that in a numerically usable gauge the divergence of the small-scale helicity flux vanishes, while the divergence of the Vishniac-Cho flux remains finite. We attribute this seeming contradiction to the existence of horizontal fluxes of small-scale magnetic helicity with finite divergences.

  17. Magnetic Helicity Flux in the Presence of Shear

    Science.gov (United States)

    Hubbard, Alexander; Brandenburg, Axel

    2011-01-01

    Magnetic helicity has risen to be a major player in dynamo theory, with the helicity of the small-scale field being linked to the dynamo saturation process for the large-scale field. It is a nearly conserved quantity, which allows its evolution equation to be written in terms of production and flux terms. The flux term can be decomposed in a variety of fashions. One particular contribution that has been expected to play a significant role in dynamos in the presence of mean shear was isolated by Vishniac & Cho. Magnetic helicity fluxes are explicitly gauge dependent however, and the correlations that have come to be called the Vishniac-Cho flux were determined in the Coulomb gauge, which turns out to be fraught with complications in shearing systems. While the fluxes of small-scale helicity are explicitly gauge dependent, their divergences can be gauge independent. We use this property to investigate magnetic helicity fluxes of the small-scale field through direct numerical simulations in a shearing-box system and find that in a numerically usable gauge the divergence of the small-scale helicity flux vanishes, while the divergence of the Vishniac-Cho flux remains finite. We attribute this seeming contradiction to the existence of horizontal fluxes of small-scale magnetic helicity with finite divergences.

  18. MANAGEMENT OF PELVIC FRACTURES IN DOG

    African Journals Online (AJOL)

    EDITOR-IN-CHIEF

    Dept. of Surgery and Radiology, College of Veterinary Science and Animal Husbandry,. Birsa Agricultural ... dogs, most of the pelvic fractures recover without surgery. .... management in the dog and cat,. New York: Thieme, pp. 161-199. FOSSUM, T.W. (2007) Pelvic fractures. In: Fossum, T.W., 3rd edn.Small. Animal Surgery.

  19. Transport barrier in Helical system

    International Nuclear Information System (INIS)

    Ida, Katsumi

    1998-01-01

    Experiments on the transport barrier in Helical plasmas are reviewed. There are two mechanisms of transport improvement, that results in the formation of the transport barrier. One is the improvement of neoclassical transport by reducing the ripple loss with radial electric field, which exist only in helical plasma. The other is the improvement of anomalous transport due to the suppression of fluctuations associated with a radial electric field shear both in tokamak and helical plasma. The formation of the transport barrier can be triggered by the radial electric field shear associated with the transition of the radial electric field (L/H transition or ion-electron root transition) or the peaked density or the optimization of magnetic field shear. The mechanisms of transport barrier formation are also discussed. (author). 60 refs

  20. Toroidal helical quartz forming machine

    International Nuclear Information System (INIS)

    Hanks, K.W.; Cole, T.R.

    1977-01-01

    The Scyllac fusion experimental machine used 10 cm diameter smooth bore discharge tubes formed into a simple toroidal shape prior to 1974. At about that time, it was discovered that a discharge tube was required to follow the convoluted shape of the load coil. A machine was designed and built to form a fused quartz tube with a toroidal shape. The machine will accommodate quartz tubes from 5 cm to 20 cm diameter forming it into a 4 m toroidal radius with a 1 to 5 cm helical displacement. The machine will also generate a helical shape on a linear tube. Two sets of tubes with different helical radii and wavelengths have been successfully fabricated. The problems encountered with the design and fabrication of this machine are discussed

  1. Stimuli-Directed Helical Chirality Inversion and Bio-Applications

    Directory of Open Access Journals (Sweden)

    Ziyu Lv

    2016-08-01

    Full Text Available Helical structure is a sophisticated ubiquitous motif found in nature, in artificial polymers, and in supramolecular assemblies from microscopic to macroscopic points of view. Significant progress has been made in the synthesis and structural elucidation of helical polymers, nevertheless, a new direction for helical polymeric materials, is how to design smart systems with controllable helical chirality, and further use them to develop chiral functional materials and promote their applications in biology, biochemistry, medicine, and nanotechnology fields. This review summarizes the recent progress in the development of high-performance systems with tunable helical chirality on receiving external stimuli and discusses advances in their applications as drug delivery vesicles, sensors, molecular switches, and liquid crystals. Challenges and opportunities in this emerging area are also presented in the conclusion.

  2. [Biomechanical modeling of pelvic organ mobility: towards personalized medicine].

    Science.gov (United States)

    Cosson, Michel; Rubod, Chrystèle; Vallet, Alexandra; Witz, Jean-François; Brieu, Mathias

    2011-11-01

    Female pelvic mobility is crucial for urinary, bowel and sexual function and for vaginal delivery. This mobility is ensured by a complex organ suspension system composed of ligaments, fascia and muscles. Impaired pelvic mobility affects one in three women of all ages and can be incapacitating. Surgical management has a high failure rate, largely owing to poor knowledge of the organ support system, including the barely discernible ligamentous system. We propose a 3D digital model of the pelvic cavity based on MRI images and quantitative tools, designed to locate the pelvic ligaments. We thus obtain a coherent anatomical and functional model which can be used to analyze pelvic pathophysiology. This work represents a first step towards creating a tool for localizing and characterizing the source of pelvic imbalance. We examine possible future applications of this model, in terms of personalized therapy and prevention.

  3. Assessment of the effect of pelvic floor exercises on pelvic floor muscle strength using ultrasonography in patients with urinary incontinence: a prospective randomized controlled trial

    OpenAIRE

    Tosun, Ozge Celiker; Solmaz, Ulas; Ekin, Atalay; Tosun, Gokhan; Gezer, Cenk; Ergenoglu, Ahmet Mete; Yeniel, Ahmet Ozgur; Mat, Emre; Malkoc, Mehtap; Askar, Niyazi

    2016-01-01

    [Purpose] The aim of this study was to evaluate whether the effect of pelvic floor exercises on pelvic floor muscle strength could be detected via ultrasonography in patients with urinary incontinence. [Subjects and Methods] Of 282 incontinent patients, 116 participated in the study and were randomly divided into a pelvic floor muscle training (n=65) group or control group (n=51). The pelvic floor muscle training group was given pelvic floor exercise training for 12 weeks. Both groups were ev...

  4. The pelvic floor muscles: muscle thickness in healthy and urinary-incontinent women measured by perineal ultrasonography with reference to the effect of pelvic floor training. Estrogen receptor studies

    DEFF Research Database (Denmark)

    Bernstein, Inge Thomsen

    1997-01-01

    demonstrated that the striated periurethral muscles and the pelvic floor muscles are of paramount importance for the closure function. This emphasizes the importance of well-functioning pelvic floor muscles to obtain continence, and probably explains the rationale for the effect of pelvic floor training...... in treating urinary incontinence. This study presents a review of the literature on female urinary incontinence, continence mechanisms, pelvic floor muscles, and pelvic floor training. Furthermore, a review of the literature on estrogen receptors in the pelvic floor muscles is given. Perineal ultrasonography...... the effect of pelvic floor training. Additionally, a study of the Pelvic floor muscles was performed to assess the presence of estrogen receptors. Muscle thickness seems to decrease with age. In women over age 60 years, a significantly thinner pelvic floor muscle was found compared to younger women...

  5. Role of laparoscopy in evaluation of chronic pelvic pain

    Directory of Open Access Journals (Sweden)

    Hebbar Shripad

    2005-01-01

    Full Text Available Introduction: Chronic pelvic pain (CPP is a common medical problem affecting women. Too often the physical signs are not specific. This study aims at determining the accuracy of diagnostic laparoscopy over clinical pelvic examination. Settings and Design: A retrospective study of patients who underwent diagnostic laparoscopy for CPP. Materials and Methods: The medical records of 86 women who underwent laparoscopic evaluation for CPP of at least 6-month duration were reviewed for presentation of symptoms, pelvic examination findings at the admission, operative findings and follow up when available. Statistical analysis used: McNemar Chi-square test for frequencies in a 2 x 2 table. Results: The most common presentation was acyclic lower abdominal pain (79.1%, followed by congestive dysmenorrhoea (26.7%. 61.6% of women did not reveal any significant signs on pelvic examination. Pelvic tenderness was elicited in 27.9%. Diagnostic laparoscopy revealed significant pelvic pathology in 58% of those who essentially had normal pervaginal findings. The most common pelvic pathology by laparoscopy was pelvic adhesions (20.9%, followed by pelvic congestion (18.6%. Laparoscopic adhesiolyis achieved pain relief only in one-third of the women. Conclusion: The study revealed very low incidence of endometriosis (4.7%. Overall clinical examination could detect abnormality in only 38% of women, where as laparoscopy could detect significant pathology in 66% of women with CPP. This shows superiority of diagnostic laparoscopy over clinical examination in detection of aetiology in women with CPP (P < 0.001. Adhesiolysis helps only small proportion of women in achieving pain control.

  6. Comprehensive pelvic floor physical therapy program for men with idiopathic chronic pelvic pain syndrome: a prospective study.

    Science.gov (United States)

    Masterson, Thomas A; Masterson, John M; Azzinaro, Jessica; Manderson, Lattoya; Swain, Sanjaya; Ramasamy, Ranjith

    2017-10-01

    Male chronic pelvic pain syndrome (CPPS) is a heterogeneous constellation of symptoms that causes significant impairment and is often challenging to treat. In this prospective study, we evaluated men with CPPS who underwent comprehensive pelvic floor physical therapy (PFPT) program. We used the previously validated Genitourinary Pain Index (GUPI) to measure outcomes. We included 14 men who underwent physical therapy for idiopathic CPPS from October 2015 to October 2016. Men with clearly identifiable causes of pelvic pain, such as previous surgery, chronic infection, trauma, prostatitis and epididymitis were excluded. Treatment included: (I) manual therapy (internal and external) of pelvic floor and abdominal musculature to facilitate relaxation of muscles; (II) therapeutic exercises to promote range of motion, improve mobility/flexibility and strengthen weak muscles; (III) biofeedback to facilitate strengthening and relaxation of pelvic floor musculature; (IV) neuromodulation for pelvic floor muscle relaxation and pain relief. GUPI questionnaires were collected at initial evaluation and after the 10th visit. Higher scores reflect worse symptoms. Previous validation of the GUPI calculated a reduction of 7 points to robustly predict being a treatment responder (sensitivity 100%, specificity 76%) and a change in 4 points to predict modest response. Data are presented as medians (ranges). A total of 10 patients completed 10 visits, and the remaining four patients completed between 5 and 9 visits. The median National Institute of Health-Chronic Prostatitis Symptom Index (NIH-CPSI) score at initial evaluation was 30.8 [16-39] and decreased to 22.2 [7-37] at the tenth visit. Five of the 10 patients (50%) in the study had a reduction of greater than 7 points indicating a robust treatment response, and two (20%) had a change of greater than 4 indicating moderate response. Three patients (30%) did not have any meaningful change in NIH-CPSI and the remaining four are in the

  7. Abutment region dosimetry for serial tomotherapy

    International Nuclear Information System (INIS)

    Low, Daniel A.; Mutic, Sasa; Dempsey, James F.; Markman, Jerry; Goddu, S. Murty; Purdy, James A.

    1999-01-01

    Purpose: A commercial intensity modulated radiation therapy system (Corvus, NOMOS Corp.) is presently used in our clinic to generate optimized dose distributions delivered using a proprietary dynamic multileaf collimator (DMLC) (MIMiC) composed of 20 opposed leaf pairs. On our accelerator (Clinac 600C/D, Varian Associates, Inc.) each MIMiC leaf projects to either 1.00 x 0.84 or 1.00 x 1.70 cm 2 (depending on the treatment plan and termed 1 cm or 2 cm mode, respectively). The MIMiC is used to deliver serial (axial) tomotherapy treatment plans, in which the beam is delivered to a nearly cylindrical volume as the DMLC is rotated about the patient. For longer targets, the patient is moved (indexed) between treatments a distance corresponding to the projected leaf width. The treatment relies on precise indexing and a method was developed to measure the precision of indexing devices. A treatment planning study of the dosimetric effects of incorrect patient indexing and concluded that a dose heterogeneity of 10% mm -1 resulted. Because the results may be sensitive to the dose model accuracy, we conducted a measurement-based investigation of the consequences of incorrect indexing using our accelerator. Although the indexing provides an accurate field abutment along the isocenter, due to beam divergence, hot and cold spots will be produced below and above isocenter, respectively, when less than 300 deg. arcs were used. A preliminary study recently determined that for a 290 deg. rotation in 1 cm mode, 15% cold and 7% hot spots were delivered to 7 cm above and below isocenter, respectively. This study completes the earlier work by investigating the dose heterogeneity as a function of position relative to the axis of rotation, arc length, and leaf width. The influence of random daily patient positioning errors is also investigated. Methods and Materials: Treatment plans were generated using 8.0 cm diameter cylindrical target volumes within a homogeneous rectilinear film

  8. Microbiota and Pelvic Inflammatory Disease

    Science.gov (United States)

    Sharma, Harsha; Tal, Reshef; Clark, Natalie A.; Segars, James H.

    2014-01-01

    Female genital tract microbiota play a crucial role in maintaining health. Disequilibrium of the microbiota has been associated with increased risk of pelvic infections. In recent years, culture-independent molecular techniques have expanded understanding of the composition of genital microbiota and the dynamic nature of the microbiota. There is evidence that upper genital tract may not be sterile and may harbor microflora in the physiologic state. The isolation of bacterial vaginosis-associated organisms in women with genital infections establishes a link between pelvic infections and abnormal vaginal flora. With the understanding of the composition of the microbiota in healthy and diseased states, the next logical step is to identify the function of the newly identified microbes. This knowledge will further expand our understanding of the causation of pelvic infections, which may lead to more effective prevention and treatment strategies. PMID:24390920

  9. Computed tomography of pelvic fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kimoto, Makoto; Hashimoto, Keiji; Hiraki, Yoshio

    1984-12-01

    Plain x-ray and computed tomographic (CT) findings were compared in 7 patients with pelvic fractures (2 males and 5 females) aged between 35 and 50 year. Plain x-rays had a higher sensitivity than CT in detecting fractures of the ischiatic and pubic ramuses, and deviation of bone fragments. CT was superior to plain x-rays near the acetabulum and in detecting deviation of bone fragments. Although there were no differences between the two modalities in detecting fractures of the wing of ilium, CT was more useful than plain x-rays in visualizing deviation of bone fragments. CT clearly visualized not only fractures but also injuries of the soft tissues, such as pelvic viscera and muscles, and the presence of hematoma. CT seems to be a useful method for observing the condition and process of pelvic injuries and for deciding treatment protocols.

  10. A new tilt on pelvic radiographs: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Richards, P.J. [North Staffordshire Royal Infirmary, Department of Radiology, Stoke-on-Trent, Staffordshire (United Kingdom); Pattison, J.M. [University Hospital of North Staffordshire, Department of Radiology, Stoke on Trent (United Kingdom); Belcher, J. [Keele University, Department of Mathematics, Keele, Staffordshire (United Kingdom); DeCann, R.W. [IMECS, Department of Radiology, Market Drayton, Shropshire (United Kingdom); Anderson, Suzanne [University of Melbourne, Department of Radiology, Melbourne (Australia); Wynn-Jones, C. [University Hospital of North Staffordshire, Department of Orthopaedic Surgery, Stoke on Trent (United Kingdom)

    2009-02-15

    The aim of this study was to evaluate pelvic tilt on commonly performed measurements on radiography in primary protrusio acetabuli and developmental dysplasia of the hip. A dry assembled pelvis and spine skeleton was positioned in an isocentric skull unit and films exposed with increasing degrees of angulation of pelvic tilt. The films were then read by two independent readers for seven different measurements used to evaluate the hips and acetabular: acetabular line to ilioischial line, teardrop appearance, intercristal/intertuberous ratio, co-ordinates of femoral head, centre edge angle, acetabular depth/width ratio and acetabular angle. There was so much variation in the protrusio results that no formal recommendation of any standard radiographic test can be given. Only the inter tuberous distance is not effected by pelvic tilt. The acetabular angles for developmental dysplasia of the hip showed the most potential with pelvic tilt below 15 . As pelvic tilt increases, measurements used in protusio become unreliable, and computed tomography/magnetic resonance imaging are probably going to be more accurate as one can directly visualise pelvic intrusion. We recommend a lateral view to assess the degree of pelvic tilt in patients with protrusion to ensure these measurements are valid. (orig.)

  11. Helicity conservation under quantum reconnection of vortex rings.

    Science.gov (United States)

    Zuccher, Simone; Ricca, Renzo L

    2015-12-01

    Here we show that under quantum reconnection, simulated by using the three-dimensional Gross-Pitaevskii equation, self-helicity of a system of two interacting vortex rings remains conserved. By resolving the fine structure of the vortex cores, we demonstrate that the total length of the vortex system reaches a maximum at the reconnection time, while both writhe helicity and twist helicity remain separately unchanged throughout the process. Self-helicity is computed by two independent methods, and topological information is based on the extraction and analysis of geometric quantities such as writhe, total torsion, and intrinsic twist of the reconnecting vortex rings.

  12. Functional imaging of the pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Lienemann, Andreas E-mail: andreaslienemann@web.de; Fischer, Tanja

    2003-08-01

    Introduction/Objective: Pelvic floor dysfunction and associated pelvic organ prolapse represent a major problem in our present-day society, mostly afflicting parous women. Magnetic resonance imaging (MRI) is assuming an increasingly important role in the more accurate delineation of the extent of the problem. This article briefly reviews one of the main radiological methods for the dynamic evaluation of the pelvic floor: functional cine MRI. Methods and Material: Out of the literature the smallest common denominator for functional cine MRI can be defined as follows: high field system; patient either in supine or sitting position; fast gradient echo sequence; midsagittal slice orientation; either a stack of slices or repeated measurements at the same slice position with the patient at rest or straining; image analysis using the pubococcygeal reference line. Results: All except two publications stress the usefulness of functional cine MRI in the evaluation of patients with organ descent and prolapse. This well accepted method allows for the visualization of all relevant structures in the anterior, middle and posterior compartment. It is especially useful in the detection of enteroceles, and provides a reliable postoperative follow-up tool. Isolated urinary or stool incontinence are not an indication for functional cine MRI, as is the case in patients with equivocal clinical findings. To date it does not allow for real 3D imaging of the pelvic floor or sufficient determination of fascial defects. Discussion: Functional cine MRI of the pelvic floor is a promising new imaging method for the detection of organ descent and prolapse in patients with equivocal clinical findings. The combination of function and morphology allows for an innovative view of the pelvic floor, and thus adds to our understanding of the various interactions of the structures.

  13. System assessment of helical reactors in comparison with tokamaks

    International Nuclear Information System (INIS)

    Yamazaki, K.; Imagawa, S.; Muroga, T.; Sagara, A.; Okamura, S.

    2002-10-01

    A comparative assessment of tokamak and helical reactors has been performed using equivalent physics/engineering model and common costing model. Higher-temperature plasma operation is required in tokamak reactors to increase bootstrap current fraction and to reduce current-drive (CD) power. In helical systems, lower-temperature operation is feasible and desirable to reduce helical ripple transport. The capital cost of helical reactor is rather high, however, the cost of electricity (COE) is almost same as that of tokamak reactor because of smaller re-circulation power (no CD power) and less-frequent blanket replacement (lower neutron wall loading). The standard LHD-type helical reactor with 5% beta value is economically equivalent to the standard tokamak with 3% beta. The COE of lower-aspect ratio helical reactor is on the same level of high-β N tokamak reactors. (author)

  14. Evaluation of the female pelvic floor in pelvic organ prolapse using 3.0-Tesla diffusion tensor imaging and fibre tractography

    Energy Technology Data Exchange (ETDEWEB)

    Zijta, F.M. [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Amsterdam and Department of Radiology, Amsterdam (Netherlands); Academic Medical Center, Department of Radiology, Amsterdam, AZ (Netherlands); Lakeman, M.M.E.; Roovers, J.P. [University of Amsterdam the Netherlands and Biomedical NMR, Amsterdam and Department of Gynaecology, Academic Medical Centre, Amsterdam (Netherlands); Froeling, M. [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Eindhoven University of Technology, Department of Biomedical Engineering, Eindhoven (Netherlands); Paardt, M.P. van der; Borstlap, C.S.V.; Bipat, S.; Nederveen, A.J.; Stoker, J. [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Montauban van Swijndregt, A.D. [Onze Lieve Vrouwe Gasthuis, Amsterdam and Department of Radiology, Amsterdam (Netherlands); Strijkers, G.J. [Eindhoven University of Technology, Department of Biomedical Engineering, Eindhoven (Netherlands)

    2012-12-15

    To prospectively explore the clinical application of diffusion tensor imaging (DTI) and fibre tractography in evaluating the pelvic floor. Ten patients with pelvic organ prolapse, ten with pelvic floor symptoms and ten asymptomatic women were included. A two-dimensional (2D) spin-echo (SE) echo-planar imaging (EPI) sequence of the pelvic floor was acquired. Offline fibre tractography and morphological analysis of pelvic magnetic resonance imaging (MRI) were performed. Inter-rater agreement for quality assessment of fibre tracking results was evaluated using weighted kappa ({kappa}). From agreed tracking results, eigen values ({lambda}1, {lambda}2, {lambda}3), mean diffusivity (MD) and fractional anisotropy (FA) were calculated. MD and FA values were compared using ANOVA. Inter-rater reliability of DTI parameters was interpreted using the intra-class correlation coefficient (ICC). Substantial inter-rater agreement was found ({kappa} = 0.71 [95% CI 0.63-0.78]). Four anatomical structures were reliably identified. Substantial inter-rater agreement was found for MD and FA (ICC 0.60-0.91). No significant differences between groups were observed for anal sphincter, perineal body and puboperineal muscle. A significant difference in FA was found for internal obturator muscle between the prolapse group and the asymptomatic group (0.27 {+-} 0.05 vs 0.22 {+-} 0.03; P = 0.015). DTI with fibre tractography permits identification of part of the clinically relevant pelvic structures. Overall, no significant differences in DTI parameters were found between groups. circle Diffusion tensor MRI offers new insights into female pelvic floor problems. (orig.)

  15. THE EFFECTS OF SPATIAL SMOOTHING ON SOLAR MAGNETIC HELICITY PARAMETERS AND THE HEMISPHERIC HELICITY SIGN RULE

    Energy Technology Data Exchange (ETDEWEB)

    Ocker, Stella Koch [Department of Physics, Oberlin College, Oberlin, OH 44074 (United States); Petrie, Gordon, E-mail: socker@oberlin.edu, E-mail: gpetrie@nso.edu [National Solar Observatory, Boulder, CO 80303 (United States)

    2016-12-01

    The hemispheric preference for negative/positive helicity to occur in the northern/southern solar hemisphere provides clues to the causes of twisted, flaring magnetic fields. Previous studies on the hemisphere rule may have been affected by seeing from atmospheric turbulence. Using Hinode /SOT-SP data spanning 2006–2013, we studied the effects of two spatial smoothing tests that imitate atmospheric seeing: noise reduction by ignoring pixel values weaker than the estimated noise threshold, and Gaussian spatial smoothing. We studied in detail the effects of atmospheric seeing on the helicity distributions across various field strengths for active regions (ARs) NOAA 11158 and NOAA 11243, in addition to studying the average helicities of 179 ARs with and without smoothing. We found that, rather than changing trends in the helicity distributions, spatial smoothing modified existing trends by reducing random noise and by regressing outliers toward the mean, or removing them altogether. Furthermore, the average helicity parameter values of the 179 ARs did not conform to the hemisphere rule: independent of smoothing, the weak-vertical-field values tended to be negative in both hemispheres, and the strong-vertical-field values tended to be positive, especially in the south. We conclude that spatial smoothing does not significantly affect the overall statistics for space-based data, and thus seeing from atmospheric turbulence seems not to have significantly affected previous studies’ ground-based results on the hemisphere rule.

  16. Transvaginal Ultrasound-Guided Aspiration of Pelvic Abscesses

    Directory of Open Access Journals (Sweden)

    P. J. Corsi

    1999-01-01

    Full Text Available Objective: To assess the utility of a less invasive approach to the care of women with a pelvic abscess, we retrospectively reviewed the outcome of women with pelvic abscesses managed by transvaginal ultrasound-guided aspiration.

  17. Straight leg elevation to rule out pelvic injury.

    Science.gov (United States)

    Bolt, Caroline; O'Keeffe, Francis; Finnegan, Pete; Dickson, Kristofer; Smit, De Villiers; Fitzgerald, Mark C; Mitra, Biswadev

    2018-02-01

    Pelvic x-ray is frequently used as a screening tool during initial assessment of injured patients. However routine use in the awake and alert blunt trauma patient may be questioned due to low yield. We propose a clinical tool that may avoid unnecessary imaging by examining whether the ability to straight leg raise, without pain, can rule out pelvic injury. We conducted a prospective cohort study with the exposure variables of ability to straight leg raise and presence of pain on doing so, and presence of pelvic fracture on x-ray as the primary outcome variable. Of the 328 participants, 35 had pelvic fractures, and of these 32 were either unable to straight leg raise, or had pain on doing so, with a sensitivity of 91.43% (95% CI: 76.94-98.2%) and a negative predictive value of 98.57% (95% CI: 95.88-99.70%). The 3 participants with a pelvic fracture who could straight leg raise with no pain, all had a GCS of less than 15, and therefore, among the sub-group of patients with GCS15, a 100% sensitivity and 100% negative predictive value for straight leg raise with no pain to rule out pelvic fracture was demonstrated. Among awake, alert patients, painless straight leg raise can exclude pelvic fractures and be incorporated into initial examination during reception and resuscitation of injured patients. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  18. Spin versus helicity in processes involving transversity

    CERN Document Server

    Mekhfi, Mustapha

    2011-01-01

    We construct the spin formalism in order to deal in a direct and natural way with processes involving transversity which are now of increasing popularity. The helicity formalism which is more appropriate for collision processes of definite helicity has been so far used also to manage processes with transversity, but at the price of computing numerous helicity amplitudes generally involving unnecessary kinematical variables.In a second step we work out the correspondence between both formalisms and retrieve in another way all results of the helicity formalism but in simpler forms.We then compute certain processes for comparison.A special process:the quark dipole magnetic moment is shown to be exclusively treated within the spin formalism as it is directly related to the transverse spin of the quark inside the baryon.

  19. The role of spiral CT in pelvic trauma management

    International Nuclear Information System (INIS)

    Cheung, E.C.F.; Fung, K.K.L.

    1999-01-01

    Rapid and accurate assessment of pelvic injury is critical for good patient management. Plain X-ray is often used as a preliminary evaluation of the injury but this may not give adequate diagnosis of the acetabulum fracture, subtle fracture of the pelvic bone and the associated soft tissue injuries. Nowadays, spiral CT has taken an increasing role in the evaluation of pelvic trauma. It gives a rapid assessment of the bone and soft tissue injuries as compared to conventional CT. Besides, 2-D (multiplanar imaging) and 3-D image reconstruction with multiple angle views, provide the maximum information which facilitates detailed pelvic trauma evaluation. Three cases were used to illustrate the role of spiral CT in pelvic trauma management. Copyright (1999) Blackwell Science Pty Ltd

  20. New formulae for magnetic relative helicity and field line helicity

    Science.gov (United States)

    Aly, Jean-Jacques

    2018-01-01

    We consider a magnetic field {B} occupying the simply connected domain D and having all its field lines tied to the boundary S of D. We assume here that {B} has a simple topology, i.e., the mapping {M} from positive to negative polarity areas of S associating to each other the two footpoints of any magnetic line, is continuous. We first present new formulae for the helicity H of {B} relative to a reference field {{B}}r having the same normal component {B}n on S, and for its field line helicity h relative to a reference vector potential {{C}}r of {{B}}r. These formulae make immediately apparent the well known invariance of these quantities under all the ideal MHD deformations that preserve the positions of the footpoints on S. They express indeed h and H either in terms of {M} and {B}n, or in terms of the values on S of a pair of Euler potentials of {B}. We next show that, for a specific choice of {{C}}r, the field line helicity h of {B} fully characterizes the magnetic mapping {M} and then the topology of the lines. Finally, we give a formula that describes the rate of change of h in a situation where the plasma moves on the perfectly conducting boundary S without changing {B}n and/or non-ideal processes, described by an unspecified term {N} in Ohm’s law, are at work in some parts of D.

  1. MR appearance of pelvic hemangiopericytoma

    Energy Technology Data Exchange (ETDEWEB)

    Kehagias, D.; Gouliamos, A.; Vlahos, L. [Dept. of Radiology, University of Athens (Greece)

    1999-02-01

    A case of pelvic hemangiopericytoma in a 59-year-old woman is reported. The MR imaging features are presented. The tumor was unresectable and the patient received postoperative irradiation of 4200 cGy on the pelvis. One year after diagnosis, metastasis to a lumbar vertebra was discovered and additional irradiation of 3900 cGy was applied. One year later, CT showed control of the pelvic tumor and its metastasis. (orig.) (orig.) With 3 figs., 10 refs.

  2. ADDITIVE SELF-HELICITY AS A KINK MODE THRESHOLD

    International Nuclear Information System (INIS)

    Malanushenko, A.; Longcope, D. W.; Fan, Y.; Gibson, S. E.

    2009-01-01

    In this paper, we propose that additive self-helicity, introduced by Longcope and Malanushenko, plays a role in the kink instability for complex equilibria, similar to twist helicity for thin flux tubes. We support this hypothesis by a calculation of additive self-helicity of a twisted flux tube from the simulation of Fan and Gibson. As more twist gets introduced, the additive self-helicity increases, and the kink instability of the tube coincides with the drop of additive self-helicity, after the latter reaches the value of H A /Φ 2 ∼ 1.5 (where Φ is the flux of the tube and H A is the additive self-helicity). We compare the additive self-helicity to twist for a thin subportion of the tube to illustrate that H A /Φ 2 is equal to the twist number, studied by Berger and Field, when the thin flux tube approximation is applicable. We suggest that the quantity H A /Φ 2 could be treated as a generalization of a twist number, when the thin flux tube approximation is not applicable. A threshold on a generalized twist number might prove extremely useful studying complex equilibria, just as the twist number itself has proven useful studying idealized thin flux tubes. We explicitly describe a numerical method for calculating additive self-helicity, which includes an algorithm for identifying a domain occupied by a flux bundle and a method of calculating potential magnetic field confined to this domain. We also describe a numerical method to calculate twist of a thin flux tube, using a frame parallelly transported along the axis of the tube.

  3. Comparative histology of mouse, rat, and human pelvic ligaments.

    Science.gov (United States)

    Iwanaga, Ritsuko; Orlicky, David J; Arnett, Jameson; Guess, Marsha K; Hurt, K Joseph; Connell, Kathleen A

    2016-11-01

    The uterosacral (USL) and cardinal ligaments (CL) provide support to the uterus and pelvic organs, and the round ligaments (RL) maintain their position in the pelvis. In women with pelvic organ prolapse (POP), the connective tissue, smooth muscle, vasculature, and innervation of the pelvic support structures are altered. Rodents are commonly used animal models for POP research. However, the pelvic ligaments have not been defined in these animals. In this study, we hypothesized that the gross anatomy and histological composition of pelvic ligaments in rodents and humans are similar. We performed an extensive literature search for anatomical and histological descriptions of the pelvic support ligaments in rodents. We also performed anatomical dissections of the pelvis to define anatomical landmarks in relation to the ligaments. In addition, we identified the histological components of the pelvic ligaments and performed quantitative analysis of the smooth muscle bundles and connective tissue of the USL and RL. The anatomy of the USL, CL, and RL and their anatomical landmarks are similar in mice, rats, and humans. All species contain the same cellular components and have similar histological architecture. However, the cervical portion of the mouse USL and RL contain more smooth muscle and less connective tissue compared with rat and human ligaments. The pelvic support structures of rats and mice are anatomically and histologically similar to those of humans. We propose that both mice and rats are appropriate, cost-effective models for directed studies in POP research.

  4. Modern Theories of Pelvic Floor Support : A Topical Review of Modern Studies on Structural and Functional Pelvic Floor Support from Medical Imaging, Computational Modeling, and Electromyographic Perspectives.

    Science.gov (United States)

    Peng, Yun; Miller, Brandi D; Boone, Timothy B; Zhang, Yingchun

    2018-02-12

    Weakened pelvic floor support is believed to be the main cause of various pelvic floor disorders. Modern theories of pelvic floor support stress on the structural and functional integrity of multiple structures and their interplay to maintain normal pelvic floor functions. Connective tissues provide passive pelvic floor support while pelvic floor muscles provide active support through voluntary contraction. Advanced modern medical technologies allow us to comprehensively and thoroughly evaluate the interaction of supporting structures and assess both active and passive support functions. The pathophysiology of various pelvic floor disorders associated with pelvic floor weakness is now under scrutiny from the combination of (1) morphological, (2) dynamic (through computational modeling), and (3) neurophysiological perspectives. This topical review aims to update newly emerged studies assessing pelvic floor support function among these three categories. A literature search was performed with emphasis on (1) medical imaging studies that assess pelvic floor muscle architecture, (2) subject-specific computational modeling studies that address new topics such as modeling muscle contractions, and (3) pelvic floor neurophysiology studies that report novel devices or findings such as high-density surface electromyography techniques. We found that recent computational modeling studies are featured with more realistic soft tissue constitutive models (e.g., active muscle contraction) as well as an increasing interest in simulating surgical interventions (e.g., artificial sphincter). Diffusion tensor imaging provides a useful non-invasive tool to characterize pelvic floor muscles at the microstructural level, which can be potentially used to improve the accuracy of the simulation of muscle contraction. Studies using high-density surface electromyography anal and vaginal probes on large patient cohorts have been recently reported. Influences of vaginal delivery on the

  5. Quality of life in women with pelvic floor dysfunction

    Directory of Open Access Journals (Sweden)

    Mladenović-Segedi Ljiljana

    2011-01-01

    Full Text Available Background/Aim. Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfaction in adult women with pelvic organ prolapse presenting to tertiary care clinic for surgical treatment. Methods. This prospective case-control study included 50 patients who presented to tertiary care gynecology clinic for surgical treatment and 50 controls with normal pelvic floor support and without urinary incontinence who presented tertiary care gynecology clinic for other reasons. Both, patients and controls, completed two quastionnaires recommended for the evaluation of symptoms (Pelvic floor distress inventory - short forms and quality of life impact (Pelvic floor impact questionnaire - short form of pelvic organ prolapse, and Body Image Scale. Results. The patients scored significantly worse on the prolapse, urinary, colorectal scales and overall score of Pelvic floor distress inventory - 20 than controls subjects (134.91 vs 78.08; p < 0.01. The patients also measured significant decrease in condition- specific quality of life (89.23 vs 3.1; p < 0.01. They were more likely to feel self-conscious (78% vs 42%; p < 0.01, less likely to feel physically attractive (78% vs 22%; p < 0.01, more likely to have difficulty looking at themselves naked (70% vs 42%; p < 0.01, less likely to feel sexually attractive (64% vs 32%; p < 0.01, and less likely to feel feminine (56% vs 16%; p < 0.05, than controls. There were no differencies in their feeling of dissatisfaction with appearance when dressed, avoiding people because of appereance and overall dissatisfaction with

  6. Verification of motion induced thread effect during tomotherapy using gel dosimetry

    International Nuclear Information System (INIS)

    Edvardsson, Anneli; Ljusberg, Anna; Ceberg, Crister; Medin, Joakim; Ambolt, Lee; Nordström, Fredrik; Ceberg, Sofie

    2015-01-01

    The purpose of the study was to evaluate how breathing motion during tomotherapy (Accuray, CA, USA) treatment affects the absorbed dose distribution. The experiments were carried out using gel dosimetry and a motion device simulating respiratory-like motion (HexaMotion, ScandiDos, Uppsala, Sweden). Normoxic polyacrylamide gels (nPAG) were irradiated, both during respiratory-like motion and in a static mode. To be able to investigate interplay effects the static absorbed dose distribution was convolved with the motion function and differences between the dynamic and convolved static absorbed dose distributions were interpreted as interplay effects. The expected dose blurring was present and the interplay effects formed a spiral pattern in the lower dose volume. This was expected since the motion induced affects the preset pitch and the theoretically predicted thread effect may emerge. In this study, the motion induced thread effect was experimentally verified for the first time

  7. Pelvic floor muscle training as a persistent nursing intervention: Effect on delivery outcome and pelvic floor myodynamia

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2014-03-01

    Conclusion: Persistent nursing intervention for pregnant/postpartum women helped to shorten the second stage of labour and contributed to the recovery of postpartum pelvic floor myodynamia. The influence of this intervention on the delivery mode, and rates of episiotomy and perineal laceration remains unknown. Medical staff should strengthen health education programmes that involve pelvic floor functional rehabilitation.

  8. [Studies on antimicrobial concentrations of flomoxef in serum, pelvic dead space exudate, and pelvic organs/tissues].

    Science.gov (United States)

    Obata, T; Koishi, K; Sasaki, J; Eguchi, M; Yamamoto, Y

    1987-10-01

    To women undergoing radical and total hysterectomy, flomoxef (FMOX, 6315-S) in a dose of 2 g was administered by intravenous drip infusion over 1 hour and drug concentrations in serum and pelvic dead space exudate as well as pelvic organs/tissues were determined over time. The following results were obtained: 1. Serum concentrations of FMOX after intravenous infusion showed the peak value of 92.86 +/- 17.05 micrograms/ml at the end of infusion and then gradually decreased to 29.00 +/- 10.49 micrograms/ml in 1 hour and 1.16 +/- 1.08 micrograms/ml in 6 hours. 2. Concentrations in pelvic dead space exudate, which were 6.54 +/- 3.21 micrograms/ml at the end of intravenous infusion, gradually increased to 31.28 +/- 12.69 micrograms/ml in 30 minutes, and the peak of 35.21 +/- 13.29 micrograms/ml in 1 hour. Exudate concentrations gradually decreased to 11.10 +/- 6.64 micrograms/ml at 6 hours after infusion. 3. The serum concentration at the ligature of uterine artery was 103.21 +/- 51.69 micrograms/ml. Among concentrations in pelvic organ/tissues 37.17 +/- 18.20 micrograms/ml in uterine cervix was the highest, followed by 35.77 +/- 7.68 micrograms/g in portio vaginalis, 26.35 +/- 14.15 micrograms/g in tube, 21.62 +/- 12.15 micrograms/g in ovary, 20.56 +/- 9.82 micrograms/g in myometrium, and 16.45 +/- 8.10 micrograms/g in endometrium, in this order. 4. From an analysis of the two-compartment model, the maximum serum concentration was 92.81 micrograms/ml, which was very high. The time of 50% reduction of concentration in beta phase was 1.21 hours. In the pelvic dead space exudate, the maximum concentration was 32.38 micrograms/ml and the time of 50% reduction was 2.44 hours. The AUC was 147 micrograms.hr/ml in serum and 201 micrograms.hr/ml in the pelvic dead space. The shift to the pelvic dead space was 137% when AUC's were used as the basis of the comparison. 5. Clinically, FMOX was excellently effective against adnexitis caused by Peptostreptococcus asaccharolyticus

  9. Clinical application of helical CT colonography

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Rujian; Liang Jianhao; Ou Weiqian; Wen Haomao

    2009-01-01

    Objective: To investigate the clinical value of 16-slice helical CT colonography in the diagnosis of colon tumor and polypus. Methods: 16-slice helical CT volumetric scanning was performed in 18 patients with colonic disease, including colonic tumor (n=16) and colonic polypus (n=2). 3D images, virtual endoscopy and multiplanar reformation were obtained in the AW4.1 workstation. CT appearances were compared with operation and fiberoptic colonoscopy. Results: Satisfied results were achieved from 18 patients, no difference found in results between CT colonography and operation in 16 patients with colonic tumor. Conclusion: 16-slice helical CT colonography is of great value in preoperative staging of colonic tumor and have a high value in clinical application. (authors)

  10. Neutrino's helicity in a gravitational field

    International Nuclear Information System (INIS)

    Pansart, J.P.

    1996-01-01

    By using approximated solutions of Dirac's equation, we show that there is no helicity reversal for light neutrinos in the Schwarzschild metric nor in an expanding universe. The actual coupling between a particle spin and the angular momentum of a heavy rotating body induces a possible helicity reversal but with an unobservable probability proportional to m 2 p / E 2 , where m p is the particle mass and E its energy. In these calculations, the helicity is defined through the spin orientation with respect to the current and not with respect to the linear momentum. This definition gives simple expressions and is equal to the usual definition in the case of a flat space. (N.T.)

  11. Treatment of symptomatic pelvic varices by ovarian vein embolization

    International Nuclear Information System (INIS)

    Capasso, Patrizio; Simons, Christine; Trotteur, Genevieve; Dondelinger, Robert F.; Henroteaux, Denis; Gaspard, Ulysse

    1997-01-01

    Purpose. Pelvic congestion syndrome is a common cause of chronic pelvic pain in women and its association with venous congestion has been described in the literature. We evaluated the potential benefits of lumboovarian vein embolization in the treatment of lower abdominal pain in patients presenting with pelvic varicosities. Methods. Nineteen patients were treated. There were 13 unilateral embolizations, 6 initial bilateral treatments and 5 treated recurrences (a total of 30 procedures). All embolizations were performed with either enbucrilate and/or macrocoils, and there was an average clinical and Doppler duplex follow-up of 15.4 months. Results. The initial technical success rate was 96.7%. There were no immediate or long-term complications. Variable symptomatic relief was observed in 73.7% of cases with complete responses in 57.9%. All 8 patients who had partial or no pain relief complained of dyspareunia. The direct relationship between varices and chronic pelvic pain was difficult to ascertain in a significant number of clinical failures. Conclusion. Transcatheter embolization of lumboovarian varices is a safe technique offering symptomatic relief of pelvic pain in the majority of cases. The presence of dyspareunia seemed to be a poor prognostic factor, indicating that other causes of pelvic pain may coexist with pelvic varicosities

  12. Introduction to the m = 1 helicity source

    International Nuclear Information System (INIS)

    Platts, D.A.; Jarboe, T.R.; Wright, B.L.

    1985-01-01

    The m = 1 Helicity Source, formerly called the Kinked Z-pinch, was developed as part of the Electrode Studies program at Los Alamos. The Electrode Studies program was initiated to study the control of electrode erosion in long discharge duration spheromak sources. Erosion control is necessary to reduce plasma impurities and to obtain adequate electrode lifetimes. The first task of the Electrode Studies program is to determine, from among a variety of configurations including the coaxial one, a helicity source geometry with good prospects for erosion control. The more efficient the helicity source the easier it will be to control erosion, but the source most also be easy to diagnose and modify if it is to be a useful test bed. The various erosion control techniques which have been proposed will require extensive experimentation to evaluate and optimize. Proposed techniques include, using refractory metals, profiling of the electrodes and magnetic fields, and various gas injection schemes including porous electrodes. It is considered necessary to do these experiments on an optimized helicity source so that the electrode geometries and plasma properties will be relevant. Therefore the present Electrode Studies program is aimed at developing an improved helicity source design

  13. Chronic Pelvic Pain

    Science.gov (United States)

    ... NSAIDs) are helpful in relieving pelvic pain, especially dysmenorrhea . Physical therapy—Acupuncture, acupressure, and nerve stimulation therapies may be useful in treating pain caused by dysmenorrhea. Physical therapy that eases trigger points may give ...

  14. Pelvic Organ Prolapse

    Science.gov (United States)

    ... the Treatment Options for Pelvic Organ Prolapse? After obtaining a detailed medical history and completing a thorough ... Food and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1- ...

  15. Bone Health and Pelvic Radiotherapy.

    Science.gov (United States)

    Higham, C E; Faithfull, S

    2015-11-01

    Survivors who have received pelvic radiotherapy make up many of the long-term cancer population, with therapies for gynaecological, bowel, bladder and prostate malignancies. Individuals who receive radiotherapy to the pelvis as part of their cancer treatment are at risk of insufficiency fractures. Symptoms of insufficiency fractures include pelvic and back pain and immobility, which can affect substantially quality of life. This constellation of symptoms can occur within 2 months of radiotherapy up to 63 months post-treatment, with a median incidence of 6-20 months. As a condition it is under reported and evidence is poor as to the contributing risk factors, causation and best management to improve the patient's bone health and mobility. As radiotherapy advances, chronic symptoms, such as insufficiency fractures, as a consequence of treatment need to be better understood and reviewed. This overview explores the current evidence for the effect of radiotherapy on bone health and insufficiency fractures and identifies what we know and where gaps in our knowledge lie. The overview concludes with the need to take seriously complaints of pelvic pain from patients after pelvic radiotherapy and to investigate and manage these symptoms more effectively. There is a clear need for definitive research in this field to provide the evidence-based guidance much needed in practice. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Magnetic Helicities and Dynamo Action in Magneto-rotational Turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Bodo, G.; Rossi, P. [INAF/Osservatorio Astrofisico di Torino, Strada Osservatorio 20, I-10025 Pino Torinese (Italy); Cattaneo, F. [Department of Astronomy and Astrophysics, The University of Chicago, 5640 S. Ellis Avenue, Chicago IL 60637 (United States); Mignone, A., E-mail: bodo@oato.inaf.it [Dipartimento di Fisica, Università degli Studi di Torino, Via Pietro Giuria 1, 10125 Torino (Italy)

    2017-07-10

    We examine the relationship between magnetic flux generation, taken as an indicator of large-scale dynamo action, and magnetic helicity, computed as an integral over the dynamo volume, in a simple dynamo. We consider dynamo action driven by magneto-rotational turbulence (MRT) within the shearing-box approximation. We consider magnetically open boundary conditions that allow a flux of helicity in or out of the computational domain. We circumvent the problem of the lack of gauge invariance in open domains by choosing a particular gauge—the winding gauge—that provides a natural interpretation in terms of the average winding number of pairwise field lines. We use this gauge precisely to define and measure the helicity and the helicity flux for several realizations of dynamo action. We find in these cases that the system as a whole does not break reflectional symmetry and that the total helicity remains small even in cases when substantial magnetic flux is generated. We find no particular connection between the generation of magnetic flux and the helicity or the helicity flux through the boundaries. We suggest that this result may be due to the essentially nonlinear nature of the dynamo processes in MRT.

  17. Estimated radiation pneumonitis risk after photon versus proton therapy alone or combined with chemotherapy for lung cancer

    DEFF Research Database (Denmark)

    Vogelius, Ivan R.; Westerly, David C; Aznar, Marianne Camille

    2011-01-01

    Background. Traditionally, radiation therapy plans are optimized without consideration of chemotherapy. Here, we model the risk of radiation pneumonitis (RP) in the presence of a possible interaction between chemotherapy and radiation dose distribution. Material and methods. Three alternative......-radiation combinations could be an interesting indication for selecting patients for proton therapy. It is likely that the IMRT plans would perform better if the CERD was accounted for during optimization, but more clinical data is required to facilitate evidence-based plan optimization in the multi-modality setting....... treatment plans are compared in 18 non-small cell lung cancer patients previously treated with helical tomotherapy; the tomotherapy plan, an intensity modulated proton therapy plan (IMPT) and a three dimensional conformal radiotherapy (3D-CRT) plan. All plans are optimized without consideration...

  18. Helicity amplitudes for matter-coupled gravity

    International Nuclear Information System (INIS)

    Aldrovandi, R.; Novaes, S.F.; Spehler, D.

    1992-07-01

    The Weyl-van der Waerden spinor formalism is applied to the evaluation of helicity invariant amplitudes in the framework of linearized gravitation. The graviton couplings to spin-0, 1 - 2 , 1, and 3 - 2 particles are given, and, to exhibit the reach of this method, the helicity amplitudes for the process electron + positron → photon + graviton are obtained. (author)

  19. Pelvic reconstruction with allogeneic bone graft after tumor resection

    Science.gov (United States)

    Wang, Wei; Bi, Wen Zhi; Yang, Jing; Han, Gang; Jia, Jin Peng

    2013-01-01

    OBJECTIVES : Pelvic reconstruction after tumor resection is challenging. METHODS: A retrospective study had been preformed to compare the outcomes among patients who received pelvic reconstructive surgery with allogeneic bone graft after en bloc resection of pelvic tumors and patients who received en bloc resection only. RESULTS: Patients without reconstruction had significantly lower functional scores at 3 months (10 vs. 15, P = 0.001) and 6 months after surgery (18.5 vs. 22, P = 0.0024), a shorter duration of hospitalization (16 day vs. 40 days, P 0.05). CONCLUSIONS : Pelvic reconstruction with allogeneic bone graft after surgical management of pelvic tumors is associated with satisfactory surgical and functional outcomes. Further clinical studies are required to explore how to select the best reconstruction method. Level of Evidence IV, Case Series. PMID:24453659

  20. Hydrodynamic studies of CNT nanofluids in helical coil heat exchanger

    Science.gov (United States)

    Babita; Sharma, S. K.; Mital Gupta, Shipra; Kumar, Arinjay

    2017-12-01

    Helical coils are extensively used in several industrial processes such as refrigeration systems, chemical reactors, recovery processes etc to accommodate a large heat transfer area within a smaller space. Nanofluids are getting great attention due to their enhanced heat transfer capability. In heat transfer equipments, pressure drop is one of the major factors of consideration for pumping power calculations. So, the present work is aimed to study hydrodynamics of CNT nanofluids in helical coils. In this study, pressure drop characteristics of CNT nanofluid flowing inside horizontal helical coils are investigated experimentally. The helical coil to tube diameter was varied from 11.71 to 27.34 keeping pitch of the helical coil constant. Double distilled water was used as basefluid. SDBS and GA surfactants were added to stablilize CNT nanofluids. The volumetric fraction of CNT nanofluid was varied from 0.003 vol% to 0.051 vol%. From the experimental data, it was analyzed that the friction factor in helical coils is greater than that of straight tubes. Concentration of CNT in nanofluids also has a significant influence on the pressure drop/friction factor of helical coils. At a constant concentration of CNT, decreasing helical coil to tube diameter from 27.24 to 11.71, fanning friction factor of helical coil; f c increases for a constant value of p/d t. This increase in the value of fanning friction factor can be attributed to the secondary flow of CNT nanofluid in helical coils.