WorldWideScience

Sample records for peak intensity variation

  1. Focused ultrasound transducer spatial peak intensity estimation: a comparison of methods

    Science.gov (United States)

    Civale, John; Rivens, Ian; Shaw, Adam; ter Haar, Gail

    2018-03-01

    Characterisation of the spatial peak intensity at the focus of high intensity focused ultrasound transducers is difficult because of the risk of damage to hydrophone sensors at the high focal pressures generated. Hill et al (1994 Ultrasound Med. Biol. 20 259-69) provided a simple equation for estimating spatial-peak intensity for solid spherical bowl transducers using measured acoustic power and focal beamwidth. This paper demonstrates theoretically and experimentally that this expression is only strictly valid for spherical bowl transducers without a central (imaging) aperture. A hole in the centre of the transducer results in over-estimation of the peak intensity. Improved strategies for determining focal peak intensity from a measurement of total acoustic power are proposed. Four methods are compared: (i) a solid spherical bowl approximation (after Hill et al 1994 Ultrasound Med. Biol. 20 259-69), (ii) a numerical method derived from theory, (iii) a method using measured sidelobe to focal peak pressure ratio, and (iv) a method for measuring the focal power fraction (FPF) experimentally. Spatial-peak intensities were estimated for 8 transducers at three drive powers levels: low (approximately 1 W), moderate (~10 W) and high (20-70 W). The calculated intensities were compared with those derived from focal peak pressure measurements made using a calibrated hydrophone. The FPF measurement method was found to provide focal peak intensity estimates that agreed most closely (within 15%) with the hydrophone measurements, followed by the pressure ratio method (within 20%). The numerical method was found to consistently over-estimate focal peak intensity (+40% on average), however, for transducers with a central hole it was more accurate than using the solid bowl assumption (+70% over-estimation). In conclusion, the ability to make use of an automated beam plotting system, and a hydrophone with good spatial resolution, greatly facilitates characterisation of the FPF, and

  2. Peak Running Intensity of International Rugby: Implications for Training Prescription.

    Science.gov (United States)

    Delaney, Jace A; Thornton, Heidi R; Pryor, John F; Stewart, Andrew M; Dascombe, Ben J; Duthie, Grant M

    2017-09-01

    To quantify the duration and position-specific peak running intensities of international rugby union for the prescription and monitoring of specific training methodologies. Global positioning systems (GPS) were used to assess the activity profile of 67 elite-level rugby union players from 2 nations across 33 international matches. A moving-average approach was used to identify the peak relative distance (m/min), average acceleration/deceleration (AveAcc; m/s 2 ), and average metabolic power (P met ) for a range of durations (1-10 min). Differences between positions and durations were described using a magnitude-based network. Peak running intensity increased as the length of the moving average decreased. There were likely small to moderate increases in relative distance and AveAcc for outside backs, halfbacks, and loose forwards compared with the tight 5 group across all moving-average durations (effect size [ES] = 0.27-1.00). P met demands were at least likely greater for outside backs and halfbacks than for the tight 5 (ES = 0.86-0.99). Halfbacks demonstrated the greatest relative distance and P met outputs but were similar to outside backs and loose forwards in AveAcc demands. The current study has presented a framework to describe the peak running intensities achieved during international rugby competition by position, which are considerably higher than previously reported whole-period averages. These data provide further knowledge of the peak activity profiles of international rugby competition, and this information can be used to assist coaches and practitioners in adequately preparing athletes for the most demanding periods of play.

  3. Peak tree: a new tool for multiscale hierarchical representation and peak detection of mass spectrometry data.

    Science.gov (United States)

    Zhang, Peng; Li, Houqiang; Wang, Honghui; Wong, Stephen T C; Zhou, Xiaobo

    2011-01-01

    Peak detection is one of the most important steps in mass spectrometry (MS) analysis. However, the detection result is greatly affected by severe spectrum variations. Unfortunately, most current peak detection methods are neither flexible enough to revise false detection results nor robust enough to resist spectrum variations. To improve flexibility, we introduce peak tree to represent the peak information in MS spectra. Each tree node is a peak judgment on a range of scales, and each tree decomposition, as a set of nodes, is a candidate peak detection result. To improve robustness, we combine peak detection and common peak alignment into a closed-loop framework, which finds the optimal decomposition via both peak intensity and common peak information. The common peak information is derived and loopily refined from the density clustering of the latest peak detection result. Finally, we present an improved ant colony optimization biomarker selection method to build a whole MS analysis system. Experiment shows that our peak detection method can better resist spectrum variations and provide higher sensitivity and lower false detection rates than conventional methods. The benefits from our peak-tree-based system for MS disease analysis are also proved on real SELDI data.

  4. Regression analysis of MCS Intensity and peak ground motion data in Italy

    Science.gov (United States)

    Faenza, L.; Michelini, A.

    2009-04-01

    Intensity scales are historically important because no instrumentation is necessary, and useful measurements of earthquake shaking can be made by an unequipped observer. The use of macroseismics data are essential for the revision of historical seismicity and of great importance for seismic hazard assessment of vulnerable areas. The procedure ShakeMap (Wald et al., Earthquake Spectra., 15, 1999) provides instrumentally based estimates of intensity maps. In Italy, intensities have been hitherto reported through the use of the MCS (Mercalli, Cancani Sieberg) intensity scale. The DBMI2004 (and the most recent DBMI08) report intensities for earthquakes in Italy that date back to Roman age. In order to exploit fully the potential of such a long intensity catalogue for past large events and with the aim of presenting ShakeMaps using an intensity scale consistent with that of the past, we have ri-calibrated the relationships between MCS intensity and observed peak ground motion (PGM) values in terms of both peak-ground acceleration and peak-ground velocities. To this end, we have used the two most updataed and complete dataset available for Italy - the strong motion Itaca database and the DBMI08 macroseismic database. In this work we have first assembled a data set consisting of PGM-intensity pairs and we have then determined the most suitable regressions parameters. Many tests have been made to quantify the accuracy and robustness of the results. The new instrumental intensity scale is going to be adopted for mapping the level of shaking resulting from earthquakes in Italy replacing the instrumental Modified Mercalli scale currently in use (Michelini et al., SRL, 79, 2008) and to determine shakemaps for historical events.

  5. Relationship between SEP Peak intensity and CME Acceleration, Speed and Width

    Science.gov (United States)

    Xie, H.; St Cyr, O. C.; Makela, P. A.; Gopalswamy, N.

    2017-12-01

    We study the large solar energetic particle (SEP) events that were detected by GOES in the >10 MeV energy channel during December 2006 to January 2016. Data used in this study includes the Solar Electron Proton Telescope (SEPT) and High Energy Telescopes (HET) on STEREO A and B, the Electron, Proton, and Alpha Monitor (EPAM) on ACE, and the Energetic and Relativistic Nuclei and Electron instrument (ERNE) on SOHO. By choosing the smallest connection angles between SEP solar locations and magnetic foot-points of each spacecraft, we divide SEP events as SOHO SEPs or STEREO SEPs. We then compute the SEP peak intensity I0 at the center of the Gausssian using the Gausssian expression from Richardson et al. (2014) and study the relationship between SEP electron and proton peak intensity and CME acceleration, speed and width. By using I0 derived from multi-spacecraft observations we found that the correlations between SEP peak intensity and CME acceleration and speed improved. We also found that this correlation can be further improved by taking into account the effects of CME width and its solar source latitude. The implication for the SEP forecast of our obtained results will be discussed.

  6. Solar cycle variations in IMF intensity

    International Nuclear Information System (INIS)

    King, J.H.

    1979-01-01

    Annual averages of logarithms of hourly interplanetary magnetic field (IMF) intensities, obtained from geocentric spacecraft between November 1963 and December 1977, reveal the following solar cycle variation. For 2--3 years at each solar minimum period, the IMF intensity is depressed by 10--15% relative to its mean value realized during a broad 9-year period contered at solar maximum. No systematic variations occur during this 9-year period. The solar minimum decrease, although small in relation to variations in some other solar wind parameters, is both statistically and physically significant

  7. Sound-Intensity Feedback During Running Reduces Loading Rates and Impact Peak.

    Science.gov (United States)

    Tate, Jeremiah J; Milner, Clare E

    2017-08-01

    Study Design Controlled laboratory study, within-session design. Background Gait retraining has been proposed as an effective intervention to reduce impact loading in runners at risk of stress fractures. Interventions that can be easily implemented in the clinic are needed. Objective To assess the immediate effects of sound-intensity feedback related to impact during running on vertical impact peak, peak vertical instantaneous loading rate, and vertical average loading rate. Methods Fourteen healthy, college-aged runners who ran at least 9.7 km/wk participated (4 male, 10 female; mean ± SD age, 23.7 ± 2.0 years; height, 1.67 ± 0.08 m; mass, 60.9 ± 8.7 kg). A decibel meter provided real-time sound-intensity feedback of treadmill running via an iPad application. Participants were asked to reduce the sound intensity of running while receiving continuous feedback for 15 minutes, while running at their self-selected preferred speed. Baseline and follow-up ground reaction force data were collected during overground running at participants' self-selected preferred running speed. Results Dependent t tests indicated a statistically significant reduction in vertical impact peak (1.56 BW to 1.13 BW, P≤.001), vertical instantaneous loading rate (95.48 BW/s to 62.79 BW/s, P = .001), and vertical average loading rate (69.09 BW/s to 43.91 BW/s, P≤.001) after gait retraining, compared to baseline. Conclusion The results of the current study support the use of sound-intensity feedback during treadmill running to immediately reduce loading rate and impact force. The transfer of within-session reductions in impact peak and loading rates to overground running was demonstrated. Decreases in loading were of comparable magnitude to those observed in other gait retraining methods. J Orthop Sports Phys Ther 2017;47(8):565-569. Epub 6 Jul 2017. doi:10.2519/jospt.2017.7275.

  8. Wavelet transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  9. Wavelett transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  10. Real-time bilinear rotation decoupling in absorptive mode J-spectroscopy: Detecting low-intensity metabolite peak close to high-intensity metabolite peak with convenience

    Science.gov (United States)

    Verma, Ajay; Baishya, Bikash

    2016-05-01

    ;Pure shift; NMR spectra display singlet peak per chemical site. Thus, high resolution is offered at the cost of valuable J-coupling information. In the present work, real-time BIRD (BIlinear Rotation Decoupling) is applied to the absorptive-mode 2D J-spectroscopy to provide pure shift spectrum in the direct dimension and J-coupling information in the indirect dimension. Quite often in metabolomics, proton NMR spectra from complex bio-fluids display tremendous signal overlap. Although conventional J-spectroscopy in principle overcomes this problem by separating the multiplet information from chemical shift information, however, only magnitude mode of the experiment is practical, sacrificing much of the potential high resolution that could be achieved. Few J-spectroscopy methods have been reported so far that produce high-resolution pure shift spectrum along with J-coupling information for crowded spectral regions. In the present work, high-quality J-resolved spectrum from important metabolomic mixture such as tissue extract from rat cortex is demonstrated. Many low-intensity metabolite peaks which are obscured by the broad dispersive tails from high-intensity metabolite peaks in regular magnitude mode J-spectrum can be clearly identified in real-time BIRD J-resolved spectrum. The general practice of removing such spectral overlap is tedious and time-consuming as it involves repeated sample preparation to change the pH of the tissue extract sample and subsequent spectra recording.

  11. The impact of soil suction variation on earthquake intensity indices

    Directory of Open Access Journals (Sweden)

    Biglari Mahnoosh

    2016-01-01

    Full Text Available Soil properties can completely change the ground motion characteristics as they travel from the bedrock to the surface because, soil as a low-pass filter, may amplify or deamplify seismic motions in some frequencies on the wave travelling path. Recent studies about the advanced unsaturated soil mechanics clearly shows that dynamic properties of soils, including small-strain shear modulus (Gmax, shear modulus reduction (G/Gmax, and damping ratio (D curves are affected by changes in the soil suction level. The current study present nonlinear time-dependent analysis of three different unsaturated soils available in the literature with different ranges of nonlinear behaviour that earlier have been studied on unsaturated dynamic models. Since, the earthquake intensity parameters can be used to describe the damage potential of an earthquake, the focus of this paper is to evaluate the impact of the suction variation on the engineering ground motion parameters, including peak values of strong motion, Vmax/Amax, root-mean-square acceleration, Arias intensity, characteristic intensity, cumulative absolute velocity, acceleration spectrum intensity, effective design acceleration, A95 parameter and predominant period separately under the near-field and the far-field seismicity categories.

  12. High intensity aerobic interval training improves peak oxygen consumption in patients with metabolic syndrome: CAT

    Directory of Open Access Journals (Sweden)

    Alexis Espinoza Salinas

    2014-06-01

    Full Text Available Introduction A number of cardiovascular risk factors characterizes the metabolic syndrome: insulin resistance (IR, low HDL cholesterol and high triglycerides. The aforementioned risk factors lead to elevated levels of abdominal adipose tissue, resulting in oxygen consumption deficiency. Purpose To verify the validity and applicability of using high intensity interval training (HIIT in subjects with metabolic syndrome and to answer the following question: Can HIIT improve peak oxygen consumption? Method The systematic review "Effects of aerobic interval training on exercise capacity and metabolic risk factors in individuals with cardiometabolic disorders" was analyzed. Results Data suggests high intensity aerobic interval training increases peak oxygen consumption by a standardized mean difference of 3.60 mL/kg-1/min-1 (95% confidence interval, 0.28-4.91. Conclusion In spite of the methodological shortcomings of the primary studies included in the systematic review, we reasonably conclude that implementation of high intensity aerobic interval training in subjects with metabolic syndrome, leads to increases in peak oxygen consumption.

  13. Latitudinal variation of the solar photospheric intensity

    OpenAIRE

    Rast, Mark P.; Ortiz, Ada; Meisner, Randle W.

    2007-01-01

    We have examined images from the Precision Solar Photometric Telescope (PSPT) at the Mauna Loa Solar Observatory (MLSO) in search of latitudinal variation in the solar photospheric intensity. Along with the expected brightening of the solar activity belts, we have found a weak enhancement of the mean continuum intensity at polar latitudes (continuum intensity enhancement $\\sim0.1 - 0.2%$ corresponding to a brightness temperature enhancement of $\\sim2.5{\\rm K}$). This appears to be thermal in ...

  14. A study of diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India

    Directory of Open Access Journals (Sweden)

    Jenny Jayapal

    2014-01-01

    Full Text Available Background: Peak Expiratory Flow Rate (PEFR reflects the strength and condition of respiratory muscles and the degree of airflow limitation in large airways. PEFR shows hour to hour variation that follows a specific pattern in asthmatics and healthy individuals. Adequate data is not available for the diurnal variation in normal individuals who are students in professional courses and had a sedentary life style. Hence, this study was undertaken to study the diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India. Materials and Methods: Peak expiratory flow rate was recorded in 50 adult healthy female students aged 18-23 years and studying in professional courses. Mini Wright′s peak flow meter was used to measure the peak expiratory flow rate. PEFR were recorded at 7-8 a.m., 10-11 a.m., 1-2 p.m., 4-5 p.m., and 7-8 p.m. for two consecutive days. Results: On analysis of PEFR records of individual subjects, it was seen that there was an overall dip in the morning at 7-8 h PEFR, which increased in the daytime, peaking in the afternoon at 1-2 p.m. and eventually decreased in the night. Subjects did not show the peak PEFR values at the same time point, 10% of subjects had a rise in PEFR in the early morning, afternoon (1-2 p.m. peak was observed in 48% subjects and evening (4-5 p.m. peak was observed in 16% subjects. 14% subjects showed a peak in the night time (7-8 p.m. PEFR values. Conclusion: This study provided the preliminary reference data of diurnal variation of peak expiratory flow rate in healthy adults. Since, there is a variation in the peak expiratory flow rate recorded during different time points of the day; hence, to compare the PEFR between individuals it is advisable to record the PEFR at the same time point.

  15. Quantification of Protein Biomarker Using SERS Nano-Stress Sensing with Peak Intensity Ratiometry

    Science.gov (United States)

    Goh, Douglas; Kong, Kien Voon; Jayakumar, Perumal; Gong, Tianxun; Dinish, U. S.; Olivo, Malini

    We report a surface enhanced Raman spectroscopy (SERS) ratiometry method based on peak intensity coupled in a nano-stress sensing platform to detect and quantify biological molecules. Herein, we employed an antibody-conjugated p-aminothiophenol (ATP) functionalized on a bimetallic-film-over-nanosphere (BMFON) substrate as a sensitive SERS platform to detect human haptoglobin (Hp) protein, which is an acute phase protein and a biomarker for various cancers. Correlation between change in the ATP spectral characteristics and concentration of Hp protein was established by examining the peak intensity ratio at 1572cm-1 and 1592cm-1 that reflects the degree of stress experienced by the aromatic ring of ATP during Hp protein-antibody interaction. Development of this platform shows the potential in developing a low-cost and sensitive SERS sensor for the pre-screening of various biomarkers.

  16. Peak flow variation in childhood asthma : Relationship to symptoms, atopy, airways obstruction and hyperresponsiveness

    NARCIS (Netherlands)

    Brand, PLP; Duiverman, EJ; Postma, DS; Waalkens, HJ; Kerrebijn, KF; vanEssenZandvliet, EEM; Quanjer, PH; Sluiter, HJ; Pouw, EM; Schoonbrood, DFME; Roos, CM; Jansen, HM; DeGooijer, A; Kerstjens, HAM; vanderMark, TW; Koeter, GH; deJong, PM; Sterk, PJ; Weaver, AMJ; Dijkman, JH; Dekhuijzen, PNR; Folgering, HTM; vanHerwaarden, CLA; Overbeek, SE; Bogaard, JM; Hilvering, C; Gans, SJ; Mengelers, HJJ; vanderBruggenBogaarts, BAHA; Kreukniet, J; Kouwenberg, JM; Prinsen, JE; Gerritsen, J; Knol, K; deMonchy, JGR; Dekker, FW; Kaptein, AA; Merkus, PJFM; Pocock, SJ; Hughes, MD; Robinson, NJ; Bleecker, ER; Meyers, DA

    Although home recording of peak expiratory flow (PEF) is considered useful in managing asthma, little is known about the relationship of PEF variation to other indicators of disease activity, We examined the relationship of PEF variation, expressed in various ways, to symptoms, atopy, level of lung

  17. Enhancement of peak intensity in a filament core with spatiotemporally focused femtosecond laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Zeng Bin; Chu Wei; Li Guihua; Zhang Haisu; Ni Jielei [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Graduate School of Chinese Academy of Sciences, Beijing 100080 (China); Gao Hui; Liu Weiwei [Institute of Modern Optics, Nankai University, Tianjin, 300071 (China); Yao Jinping; Cheng Ya; Xu Zhizhan [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Chin, See Leang [Center for Optics, Photonics and Laser (COPL) and Department of Physics, Engineering Physics and Optics, Universite Laval, Quebec City, QC, G1V 0A6 (Canada)

    2011-12-15

    We demonstrate that the peak intensity in the filament core, which is inherently limited by the intensity clamping effect during femtosecond laser filamentation, can be significantly enhanced using spatiotemporally focused femtosecond laser pulses. In addition, the filament length obtained by spatiotemporally focused femtosecond laser pulses is {approx}25 times shorter than that obtained by a conventional focusing scheme, resulting in improved high spatial resolution.

  18. LONGITUDINAL AND RADIAL DEPENDENCE OF SOLAR ENERGETIC PARTICLE PEAK INTENSITIES: STEREO, ACE, SOHO, GOES, AND MESSENGER OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Lario, D.; Ho, G. C.; Decker, R. B.; Roelof, E. C. [The Johns Hopkins University, Applied Physics Laboratory, Laurel, MD 20723 (United States); Aran, A. [Departament d' Astronomia i Meteorologia, Institut de Ciencies del Cosmos, Universitat de Barcelona, Barcelona (Spain); Gomez-Herrero, R.; Dresing, N.; Heber, B., E-mail: david.lario@jhuapl.edu [Institute of Experimental and Applied Physics, Christian-Albrechts University of Kiel, Kiel (Germany)

    2013-04-10

    Simultaneous measurements of solar energetic particle (SEP) events by two or more of the spacecraft located near 1 AU during the rising phase of solar cycle 24 (i.e., STEREO-A, STEREO-B, and near-Earth spacecraft such as ACE, SOHO, and GOES) are used to determine the longitudinal dependence of 71-112 keV electron, 0.7-3 MeV electron, 15-40 MeV proton, and 25-53 MeV proton peak intensities measured in the prompt component of SEP events. Distributions of the peak intensities for the selected 35 events with identifiable solar origin are approximated by the form exp [ - ({phi} - {phi}{sub 0}){sup 2}/2{sigma}{sup 2}], where {phi} is the longitudinal separation between the parent active region and the footpoint of the nominal interplanetary magnetic field (IMF) line connecting each spacecraft with the Sun, {phi}{sub 0} is the distribution centroid, and {sigma} determines the longitudinal gradient. The MESSENGER spacecraft, at helioradii R < 1 AU, allows us to determine a lower limit to the radial dependence of the 71-112 keV electron peak intensities measured along IMF lines. We find five events for which the nominal magnetic footpoint of MESSENGER was less than 20 Degree-Sign apart from the nominal footpoint of a spacecraft near 1 AU. Although the expected theoretical radial dependence for the peak intensity of the events observed along the same field line can be approximated by a functional form R {sup -{alpha}} with {alpha} < 3, we find two events for which {alpha} > 3. These two cases correspond to SEP events occurring in a complex interplanetary medium that favored the enhancement of peak intensities near Mercury but hindered the SEP transport to 1 AU.

  19. Reference values for peak flow and FEV1 variation in healthy schoolchildren using home spirometry

    NARCIS (Netherlands)

    Brouwer, A. F. J.; Duiverman, E. J.; Brand, P. L. P.

    2008-01-01

    Current reference values for diurnal peak flow variation in healthy children (median 8.2%; 95th percentile 31%) are so high that considerable overlap exists with those of asthmatic children. These values have been obtained using written peak flow diaries, which are unreliable. The aim of the present

  20. Variations in embodied energy and carbon emission intensities of construction materials

    Energy Technology Data Exchange (ETDEWEB)

    Wan Omar, Wan-Mohd-Sabki [Griffith School of Engineering, Griffith University, Gold Coast Campus, Queensland 4222 (Australia); School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis (Malaysia); Doh, Jeung-Hwan, E-mail: j.doh@griffith.edu.au [Griffith School of Engineering, Griffith University, Gold Coast Campus, Queensland 4222 (Australia); Panuwatwanich, Kriengsak [Griffith School of Engineering, Griffith University, Gold Coast Campus, Queensland 4222 (Australia)

    2014-11-15

    Identification of parameter variation allows us to conduct more detailed life cycle assessment (LCA) of energy and carbon emission material over their lifecycle. Previous research studies have demonstrated that hybrid LCA (HLCA) can generally overcome the problems of incompleteness and accuracy of embodied energy (EE) and carbon (EC) emission assessment. Unfortunately, the current interpretation and quantification procedure has not been extensively and empirically studied in a qualitative manner, especially in hybridising between the process LCA and I-O LCA. To determine this weakness, this study empirically demonstrates the changes in EE and EC intensities caused by variations to key parameters in material production. Using Australia and Malaysia as a case study, the results are compared with previous hybrid models to identify key parameters and issues. The parameters considered in this study are technological changes, energy tariffs, primary energy factors, disaggregation constant, emission factors, and material price fluctuation. It was found that changes in technological efficiency, energy tariffs and material prices caused significant variations in the model. Finally, the comparison of hybrid models revealed that non-energy intensive materials greatly influence the variations due to high indirect energy and carbon emission in upstream boundary of material production, and as such, any decision related to these materials should be considered carefully. - Highlights: • We investigate the EE and EC intensity variation in Australia and Malaysia. • The influences of parameter variations on hybrid LCA model were evaluated. • Key significant contribution to the EE and EC intensity variation were identified. • High indirect EE and EC content caused significant variation in hybrid LCA models. • Non-energy intensive material caused variation between hybrid LCA models.

  1. Variations in embodied energy and carbon emission intensities of construction materials

    International Nuclear Information System (INIS)

    Wan Omar, Wan-Mohd-Sabki; Doh, Jeung-Hwan; Panuwatwanich, Kriengsak

    2014-01-01

    Identification of parameter variation allows us to conduct more detailed life cycle assessment (LCA) of energy and carbon emission material over their lifecycle. Previous research studies have demonstrated that hybrid LCA (HLCA) can generally overcome the problems of incompleteness and accuracy of embodied energy (EE) and carbon (EC) emission assessment. Unfortunately, the current interpretation and quantification procedure has not been extensively and empirically studied in a qualitative manner, especially in hybridising between the process LCA and I-O LCA. To determine this weakness, this study empirically demonstrates the changes in EE and EC intensities caused by variations to key parameters in material production. Using Australia and Malaysia as a case study, the results are compared with previous hybrid models to identify key parameters and issues. The parameters considered in this study are technological changes, energy tariffs, primary energy factors, disaggregation constant, emission factors, and material price fluctuation. It was found that changes in technological efficiency, energy tariffs and material prices caused significant variations in the model. Finally, the comparison of hybrid models revealed that non-energy intensive materials greatly influence the variations due to high indirect energy and carbon emission in upstream boundary of material production, and as such, any decision related to these materials should be considered carefully. - Highlights: • We investigate the EE and EC intensity variation in Australia and Malaysia. • The influences of parameter variations on hybrid LCA model were evaluated. • Key significant contribution to the EE and EC intensity variation were identified. • High indirect EE and EC content caused significant variation in hybrid LCA models. • Non-energy intensive material caused variation between hybrid LCA models

  2. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Meijer, G. G.; Postma, D. S.; van der Heide, S.; de Reus, D. M.; Roorda, R. J.; Koëter, G. H.; van Aalderen, W. M.

    1996-01-01

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  3. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Postma, DS; VanderHeide, S; DeReus, DM; Koeter, GH; VanAalderen, WMC; Meijer, G.

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  4. How would peak rainfall intensity affect runoff predictions using conceptual water balance models?

    Directory of Open Access Journals (Sweden)

    B. Yu

    2015-06-01

    Full Text Available Most hydrological models use continuous daily precipitation and potential evapotranspiration for streamflow estimation. With the projected increase in mean surface temperature, hydrological processes are set to intensify irrespective of the underlying changes to the mean precipitation. The effect of an increase in rainfall intensity on the long-term water balance is, however, not adequately accounted for in the commonly used hydrological models. This study follows from a previous comparative analysis of a non-stationary daily series of stream flow of a forested watershed (River Rimbaud in the French Alps (area = 1.478 km2 (1966–2006. Non-stationarity in the recorded stream flow occurred as a result of a severe wild fire in 1990. Two daily models (AWBM and SimHyd were initially calibrated for each of three distinct phases in relation to the well documented land disturbance. At the daily and monthly time scales, both models performed satisfactorily with the Nash–Sutcliffe coefficient of efficiency (NSE varying from 0.77 to 0.92. When aggregated to the annual time scale, both models underestimated the flow by about 22% with a reduced NSE at about 0.71. Exploratory data analysis was undertaken to relate daily peak hourly rainfall intensity to the discrepancy between the observed and modelled daily runoff amount. Preliminary results show that the effect of peak hourly rainfall intensity on runoff prediction is insignificant, and model performance is unlikely to improve when peak daily precipitation is included. Trend analysis indicated that the large decrease of precipitation when daily precipitation amount exceeded 10–20 mm may have contributed greatly to the decrease in stream flow of this forested watershed.

  5. Propagation of Solar Energetic Particles in Three-dimensional Interplanetary Magnetic Fields: Radial Dependence of Peak Intensities

    Science.gov (United States)

    He, H.-Q.; Zhou, G.; Wan, W.

    2017-06-01

    A functional form {I}\\max (R)={{kR}}-α , where R is the radial distance of a spacecraft, was usually used to model the radial dependence of peak intensities {I}\\max (R) of solar energetic particles (SEPs). In this work, the five-dimensional Fokker-Planck transport equation incorporating perpendicular diffusion is numerically solved to investigate the radial dependence of SEP peak intensities. We consider two different scenarios for the distribution of a spacecraft fleet: (1) along the radial direction line and (2) along the Parker magnetic field line. We find that the index α in the above expression varies in a wide range, primarily depending on the properties (e.g., location and coverage) of SEP sources and on the longitudinal and latitudinal separations between the sources and the magnetic foot points of the observers. Particularly, whether the magnetic foot point of the observer is located inside or outside the SEP source is a crucial factor determining the values of index α. A two-phase phenomenon is found in the radial dependence of peak intensities. The “position” of the break point (transition point/critical point) is determined by the magnetic connection status of the observers. This finding suggests that a very careful examination of the magnetic connection between the SEP source and each spacecraft should be taken in the observational studies. We obtain a lower limit of {R}-1.7+/- 0.1 for empirically modeling the radial dependence of SEP peak intensities. Our findings in this work can be used to explain the majority of the previous multispacecraft survey results, and especially to reconcile the different or conflicting empirical values of the index α in the literature.

  6. Occupational Variation in End-of-Life Care Intensity.

    Science.gov (United States)

    Hyder, Joseph A; Haring, R Sterling; Sturgeon, Daniel; Gazarian, Priscilla K; Jiang, Wei; Cooper, Zara; Lipsitz, Stuart R; Prigerson, Holly G; Weissman, Joel S

    2018-03-01

    End-of-life (EOL) care intensity is known to vary by secular and geographic patterns. US physicians receive less aggressive EOL care than the general population, presumably the result of preferences shaped by work-place experience with EOL care. We investigated occupation as a source of variation in EOL care intensity. Across 4 states, we identified 660 599, nonhealth maintenance organization Medicare beneficiaries aged ≥66 years who died between 2004 and 2011. Linking death certificates, we identified beneficiaries with prespecified occupations: nurses, farmers, clergy, mortuary workers, homemakers, first-responders, veterinary workers, teachers, accountants, and the general population. End-of-life care intensity over the last 6 months of life was assessed using 5 validated measures: (1) Medicare expenditures, rates of (2) hospice, (3) surgery, (4) intensive care, and (5) in-hospital death. Occupation was a source of large variation in EOL care intensity across all measures, before and after adjustment for sex, education, age-adjusted Charlson Comorbidity Index, race/ethnicity, and hospital referral region. For example, absolute and relative adjusted differences in expenditures were US$9991 and 42% of population mean expenditure ( P EOL care intensity measures, teachers (5 of 5), homemakers (4 of 5), farmers (4 of 5), and clergy (3 of 5) demonstrated significantly less aggressive care. Mortuary workers had lower EOL care intensity (4 of 5) but small numbers limited statistical significance. Occupations with likely exposure to child development, death/bereavement, and naturalistic influences demonstrated lower EOL care intensity. These findings may inform patients and clinicians navigating choices around individual EOL care preferences.

  7. Intracyclic Velocity Variation of the Center of Mass and Hip in Breaststroke Swimming With Maximal Intensity.

    Science.gov (United States)

    Gourgoulis, Vassilios; Koulexidis, Stylianos; Gketzenis, Panagiotis; Tzouras, Grigoris

    2018-03-01

    Gourgoulis, V, Koulexidis, S, Gketzenis, P, and Tzouras, G. Intra-cyclic velocity variation of the center of mass and hip in breaststroke swimming with maximal intensity. J Strength Cond Res 32(3): 830-840, 2018-The aim of the study was to compare the center of mass (CM) and hip (HIP) intracyclic velocity variation in breaststroke swimming using 3-dimensional kinematic analysis. Nine male breaststrokes, of moderate performance level, swam 25-m breaststroke with maximal intensity, and their movements were recorded, both under and above the water surface, using 8 digital cameras. Their CM and HIP velocities and their intracyclic variations were estimated after manual digitization of 28 selected points on the body in a complete arm and leg breaststroke cycle. Paired sample t-tests or Wilcoxon tests, when the assumption of normality was broken, were used for statistical analyses. In both, CM and HIP velocity-time curves, the results revealed a similar pattern of 2 clear peaks associated with the leg and arm propulsive phases and 2 minimal velocities that corresponded to the arm and leg recovery phase and the lag time between the leg and arm propulsive phases, respectively. However, despite this similar general pattern, the HIP minimum resultant velocity was significantly lower, whereas its maximal value was significantly greater, than the corresponding CM values. Consequently, the HIP intracyclic swimming velocity fluctuation significantly overestimates the actual variation of the swimmer's velocity in breaststroke swimming.

  8. Climate-related variation in plant peak biomass and growth phenology across Pacific Northwest tidal marshes

    Science.gov (United States)

    Buffington, Kevin J.; Dugger, Bruce D.; Thorne, Karen M.

    2018-03-01

    The interannual variability of tidal marsh plant phenology is largely unknown and may have important ecological consequences. Marsh plants are critical to the biogeomorphic feedback processes that build estuarine soils, maintain marsh elevation relative to sea level, and sequester carbon. We calculated Tasseled Cap Greenness, a metric of plant biomass, using remotely sensed data available in the Landsat archive to assess how recent climate variation has affected biomass production and plant phenology across three maritime tidal marshes in the Pacific Northwest of the United States. First, we used clipped vegetation plots at one of our sites to confirm that tasseled cap greenness provided a useful measure of aboveground biomass (r2 = 0.72). We then used multiple measures of biomass each growing season over 20-25 years per study site and developed models to test how peak biomass and the date of peak biomass varied with 94 climate and sea-level metrics using generalized linear models and Akaike Information Criterion (AIC) model selection. Peak biomass was positively related to total annual precipitation, while the best predictor for date of peak biomass was average growing season temperature, with the peak 7.2 days earlier per degree C. Our study provides insight into how plants in maritime tidal marshes respond to interannual climate variation and demonstrates the utility of time-series remote sensing data to assess ecological responses to climate stressors.

  9. GRB physics and cosmology with peak energy-intensity correlations

    Energy Technology Data Exchange (ETDEWEB)

    Sawant, Disha, E-mail: sawant@fe.infn.it [University of Ferrara, Via Saragat-1, Block C, Ferrara 44122 (Italy); University of Nice, 28 Avenue Valrose, Nice 06103 (France); IRAP Erasmus PhD Program, European Union and INAF - IASF Bologna, Via P. Gobetti 101, Bologna 41125 (Italy); Amati, Lorenzo, E-mail: amati@iasfbo.inaf.it [INAF - IASF Bologna, Via P. Gobetti 101, Bologna 41125 (Italy); ICRANet, Piazzale Aldo Moro-5, Rome 00185 (Italy)

    2015-12-17

    Gamma Ray Bursts (GRBs) are immensely energetic explosions radiating up to 10{sup 54} erg of energy isotropically (E{sub iso}) and they are observed within a wide range of redshift (from ∼ 0.01 up to ∼ 9). Such enormous power and high redshift point at these phenomena being highly favorable to investigate the history and evolution of our universe. The major obstacle in their application as cosmological study-tools is to find a way to standardize the GRBs, for instance similar to SNe Ia. With respect to this goal, the correlation between spectral peak energy (E{sub p,i}) and the “intensity” is a positively useful and investigated criterion. Moreover, it has been demonstrated that, through the E{sub p,i} – E{sub iso} correlation, the current data set of GRBs can already contribute to the independent evidence of the matter density Ω{sub M} being ∼ 0.3 for a flat universe scenario. We try to inspect and compare the correlations of E{sub p,i} with different intensity indicators (e.g., radiated energy, average and peak luminosity, bolometric vs. monochromatic quantities, etc.) both in terms of intrinsic dispersion and precise estimation of Ω{sub M}. The outcome of such studies are further analyzed in verifying the reliability of the correlations for both GRB physics and their standardization for cosmology.

  10. LONGITUDINAL AND RADIAL DEPENDENCE OF SOLAR ENERGETIC PARTICLE PEAK INTENSITIES: STEREO, ACE, SOHO, GOES, AND MESSENGER OBSERVATIONS

    International Nuclear Information System (INIS)

    Lario, D.; Ho, G. C.; Decker, R. B.; Roelof, E. C.; Aran, A.; Gómez-Herrero, R.; Dresing, N.; Heber, B.

    2013-01-01

    Simultaneous measurements of solar energetic particle (SEP) events by two or more of the spacecraft located near 1 AU during the rising phase of solar cycle 24 (i.e., STEREO-A, STEREO-B, and near-Earth spacecraft such as ACE, SOHO, and GOES) are used to determine the longitudinal dependence of 71-112 keV electron, 0.7-3 MeV electron, 15-40 MeV proton, and 25-53 MeV proton peak intensities measured in the prompt component of SEP events. Distributions of the peak intensities for the selected 35 events with identifiable solar origin are approximated by the form exp [ – (φ – φ 0 ) 2 /2σ 2 ], where φ is the longitudinal separation between the parent active region and the footpoint of the nominal interplanetary magnetic field (IMF) line connecting each spacecraft with the Sun, φ 0 is the distribution centroid, and σ determines the longitudinal gradient. The MESSENGER spacecraft, at helioradii R –α with α 3. These two cases correspond to SEP events occurring in a complex interplanetary medium that favored the enhancement of peak intensities near Mercury but hindered the SEP transport to 1 AU.

  11. Sub-annual paleoenvironmental information evaluated from intensity variations of fluorescent annual layers in a stalagmite from Ryuo-do Cave, Nagasaki Prefecture, western Japan

    Science.gov (United States)

    Sasaki, Hana; Onishi, Yuri; Ishihara, Yoshiro; Yoshimura, Kazuhisa

    2017-04-01

    Stalagmites can provide various types of paleoenvironmental information such as information on vegetation and climate changes. Fluorescent annual layers formed by humic substances (mainly fulvic acids: FA) in these stalagmites can also provide a time proxy, and a time series on precipitation. Fluorescence intensity patterns in these annual layers can be classified into symmetric, gradually increasing and gradually decreasing types. Onishi et al. (EGU2016) demonstrated the existence of these fluorescence intensity patterns in the annual layers, and their stratigraphic changes, by numerical simulations, and suggested that the patterns could provide paleoenvironmental information at a sub-annual resolution. In this study, we carried out an analysis of fluorescence intensity patterns in the annual layers of a stalagmite from Ryuo-do Cave, Nagasaki Prefecture, western Japan, and also simulated the patterns in the stalagmite, to obtain paleoenvironmental information. Fluorescence intensity patterns in the annual layers are strongly affected by annual variations in FA concentration and precipitation rates of calcite. As the result of simulations of fluorescence intensity patterns, cumulative variations and various types of pattern are reproduced. These differences are depending on time lags between the variation of the FA concentration in the drip waters, and that of the growth rate of the stalagmite. Co-precipitation models of FA are divided into the "Hiatus model" in which FA are preferentially preserved in the stalagmite when its growth rate is relatively low, and the "Partition coefficient (PC) model" in which FA concentrations in the stalagmite increase when the calcite precipitation rate is relatively high. However, various fluorescence intensity patterns in the annual layers could be formed under a combination or either of both of the models. Fluorescence intensity patterns in an annual layer in the stalagmite from Ryuo-do Cave, Nagasaki Prefecture, western Japan

  12. Climate-related variation in plant peak biomass and growth phenology across Pacific Northwest tidal marshes

    Science.gov (United States)

    Buffington, Kevin J.; Dugger, Bruce D.; Thorne, Karen M.

    2018-01-01

    The interannual variability of tidal marsh plant phenology is largely unknown and may have important ecological consequences. Marsh plants are critical to the biogeomorphic feedback processes that build estuarine soils, maintain marsh elevation relative to sea level, and sequester carbon. We calculated Tasseled Cap Greenness, a metric of plant biomass, using remotely sensed data available in the Landsat archive to assess how recent climate variation has affected biomass production and plant phenology across three maritime tidal marshes in the Pacific Northwest of the United States. First, we used clipped vegetation plots at one of our sites to confirm that tasseled cap greenness provided a useful measure of aboveground biomass (r2 = 0.72). We then used multiple measures of biomass each growing season over 20–25 years per study site and developed models to test how peak biomass and the date of peak biomass varied with 94 climate and sea-level metrics using generalized linear models and Akaike Information Criterion (AIC) model selection. Peak biomass was positively related to total annual precipitation, while the best predictor for date of peak biomass was average growing season temperature, with the peak 7.2 days earlier per degree C. Our study provides insight into how plants in maritime tidal marshes respond to interannual climate variation and demonstrates the utility of time-series remote sensing data to assess ecological responses to climate stressors.

  13. Time variations in geomagnetic intensity

    Science.gov (United States)

    Valet, Jean-Pierre

    2003-03-01

    After many years spent by paleomagnetists studying the directional behavior of the Earth's magnetic field at all possible timescales, detailed measurements of field intensity are now needed to document the variations of the entire vector and to analyze the time evolution of the field components. A significant step has been achieved by combining intensity records derived from archeological materials and from lava flows in order to extract the global field changes over the past 12 kyr. A second significant step was due to the emergence of coherent records of relative paleointensity using the remanent magnetization of sediments to retrace the evolution of the dipole field. A third step was the juxtaposition of these signals with those derived from cosmogenic isotopes. Contemporaneous with the acquisition of records, new techniques have been developed to constrain the geomagnetic origin of the signals. Much activity has also been devoted to improving the quality of determinations of absolute paleointensity from volcanic rocks with new materials, proper selection of samples, and investigations of complex changes in magnetization during laboratory experiments. Altogether these developments brought us from a situation where the field changes were restricted to the past 40 kyr to the emergence of a coherent picture of the changes in the geomagnetic dipole moment for at least the past 1 Myr. On longer timescales the field variability and its average behavior is relatively well documented for the past 400 Myr. Section 3 gives a summary of most methods and techniques that are presently used to track the field intensity changes in the past. In each case, current limits and potential promises are discussed. The section 4 describes the field variations measured so far over various timescales covered by the archeomagnetic and the paleomagnetic records. Preference has always been given to composite records and databases in order to extract and discuss major and global geomagnetic

  14. Rapid geomagnetic field intensity variations in the Near East during the 6th millennium BC: New archeointensity data from Halafian site Yarim Tepe II (Northern Iraq)

    Science.gov (United States)

    Yutsis-Akimova, Stanislava; Gallet, Yves; Amirov, Shahmardan

    2018-01-01

    further suggests that the intensity secular variation in the Near East and in Eastern Europe during the 6th millennium BC was in fact principally punctuated by two successive short-lasting intensity peaks, the first around 5800 BC and the second around 5500 BC. The scarcity of the intensity data available worldwide, however, prevents us constraining the geomagnetic dipole or non-dipole origin of these features. The variation rates associated with the rapid intensity fluctuations observed in Yarim Tepe II are of ∼0.15-0.25 μT/yr. This range of values appears similar to that of rapid intensity variations that sporadically occurred in more recent times, such as in Western Europe around 700 BC and 1000 AD. In contrast, it is lower than the variation rates that were proposed for geomagnetic spikes. Our results also have interesting implications on Halafian archeology; in particular, they suggest that the Late Halaf-HUT boundary was older by ∼ one century than previously considered.

  15. Three dimensional analysis of cosmic ray intensity variation

    International Nuclear Information System (INIS)

    Yasue, Shin-ichi; Mori, Satoru; Nagashima, Kazuo.

    1974-01-01

    Three dimensional analysis of cosmic ray anisotropy and its time variation was performed. This paper describes the analysis of the Forbush decrease in Jan. 1968 to investigate by comparing the direction of the magnetic field in interplanetary space and the direction of the reference axis for cosmic ray anisotropy. New anisotropy becomes dominant at the time of Forbush decrease because the anisotropy of cosmic ray in calm state is wiped out. Such anisotropy produces intensity variation in neutron monitors on the ground. The characteristic parameters of three dimensional anisotropy can be determined from theoretical value and observed intensity. Analyzed data were taken for 6 days from Jan. 25 to Jan. 30, 1968, at Deep River. The decrease of intensity at Deep River was seen for several hours from 11 o'clock (UT), Jan. 26, just before The Forbush decrease. This may be due to the loss cone. The Forbush decrease began at 19 o'clock, Jan. 26, and the main phase continued to 5 o'clock in the next morning. The spectrum of variation was Psup(-0.5). The time variations of the magnetic field in interplanetary space and the reference axis of cosmic ray anisotropy are shown for 15 hours. The average directions of both are almost in coincidence. The spatial distribution of cosmic ray near the earth may be expressed by the superposition of axial symmetrical distribution along a reference axis and its push-out to the direction of 12 o'clock. It is considered that the direction of magnetic force line and the velocity of solar wind correspond to the direction of the reference axis and the magnitude of anisotropy in the direction of 12 o'clock, respectively. (Kato, T.)

  16. Changes in the Long-Term Intensity Variations in Cygnus X-2 and LMC X-3

    Science.gov (United States)

    Paul, B.; Kitamoto, S.; Makino, F.

    2000-01-01

    We report the detection of changes in the long-term intensity variations in two X-ray binaries, Cyg X-2 and LMC X-3. In this work, we have used the long-term light curves obtained with the All-Sky Monitors (ASMs) of the Rossi X-Ray Timing Explorer (RXTE), Ginga, Ariel 5, and Vela 5B and the scanning modulation collimator of HEAO 1. It is found that in the light curves of both the sources, obtained with these instruments at various times over the last 30 years, more than one periodic or quasi-periodic component is always present. The multiple prominent peaks in the periodograms have frequencies unrelated to each other. In Cyg X-2, RXTE-ASM data show strong peaks at 40.4 and 68.8 days, and Ginga-ASM data show strong peaks at 53.7 and 61.3 days. Multiple peaks are also observed in LMC X-3. The various strong peaks in the periodograms of LMC X-3 appear at 104, 169, and 216 days (observed with RXTE-ASM) and 105, 214, and 328 days (observed with Ginga-ASM). The present results, when compared with the earlier observations of periodicities in these two systems, demonstrate the absence of any stable long period. The 78 day periodicity detected earlier in Cyg X-2 was probably due to the short time base in the RXTE data that were used, and the periodicity of 198 days in LMC X-3 was due to a relatively short duration of observation with HEAO 1.

  17. Respiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia.

    Science.gov (United States)

    Morparia, Kavita G; Reddy, Srijaya K; Olivieri, Laura J; Spaeder, Michael C; Schuette, Jennifer J

    2018-04-01

    The determination of fluid responsiveness in the critically ill child is of vital importance, more so as fluid overload becomes increasingly associated with worse outcomes. Dynamic markers of volume responsiveness have shown some promise in the pediatric population, but more research is needed before they can be adopted for widespread use. Our aim was to investigate effectiveness of respiratory variation in peak aortic velocity and pulse pressure variation to predict fluid responsiveness, and determine their optimal cutoff values. We performed a prospective, observational study at a single tertiary care pediatric center. Twenty-one children with normal cardiorespiratory status undergoing general anesthesia for neurosurgery were enrolled. Respiratory variation in peak aortic velocity (ΔVpeak ao) was measured both before and after volume expansion using a bedside ultrasound device. Pulse pressure variation (PPV) value was obtained from the bedside monitor. All patients received a 10 ml/kg fluid bolus as volume expansion, and were qualified as responders if stroke volume increased >15% as a result. Utility of ΔVpeak ao and PPV and to predict responsiveness to volume expansion was investigated. A baseline ΔVpeak ao value of greater than or equal to 12.3% best predicted a positive response to volume expansion, with a sensitivity of 77%, specificity of 89% and area under receiver operating characteristic curve of 0.90. PPV failed to demonstrate utility in this patient population. Respiratory variation in peak aortic velocity is a promising marker for optimization of perioperative fluid therapy in the pediatric population and can be accurately measured using bedside ultrasonography. More research is needed to evaluate the lack of effectiveness of pulse pressure variation for this purpose.

  18. Empirical model for the electron density peak height disturbance in response to solar wind conditions

    Science.gov (United States)

    Blanch, E.; Altadill, D.

    2009-04-01

    Geomagnetic storms disturb the quiet behaviour of the ionosphere, its electron density and the electron density peak height, hmF2. Many works have been done to predict the variations of the electron density but few efforts have been dedicated to predict the variations the hmF2 under disturbed helio-geomagnetic conditions. We present the results of the analyses of the F2 layer peak height disturbances occurred during intense geomagnetic storms for one solar cycle. The results systematically show a significant peak height increase about 2 hours after the beginning of the main phase of the geomagnetic storm, independently of both the local time position of the station at the onset of the storm and the intensity of the storm. An additional uplift is observed in the post sunset sector. The duration of the uplift and the height increase are dependent of the intensity of the geomagnetic storm, the season and the local time position of the station at the onset of the storm. An empirical model has been developed to predict the electron density peak height disturbances in response to solar wind conditions and local time which can be used for nowcasting and forecasting the hmF2 disturbances for the middle latitude ionosphere. This being an important output for EURIPOS project operational purposes.

  19. Relating Solar Energetic Particle Event Fluences to Peak Intensities

    Science.gov (United States)

    Kahler, Stephen W.; Ling, Alan G.

    2018-02-01

    Recently we (Kahler and Ling, Solar Phys. 292, 59, 2017: KL) have shown that time-intensity profiles [I(t)] of 14 large solar energetic particle (SEP) events can be fitted with a simple two-parameter fit, the modified Weibull function, which is characterized by shape and scaling parameters [α and β]. We now look for a simple correlation between an event peak energy intensity [Ip] and the time integral of I(t) over the event duration: the fluence [F]. We first ask how the ratio of F/Ip varies for the fits of the 14 KL events and then examine that ratio for three separate published statistical studies of SEP events in which both F and Ip were measured for comparisons of those parameters with various solar-flare and coronal mass ejection (CME) parameters. The three studies included SEP energies from a 4 - 13 MeV band to E > 100 MeV. Within each group of SEP events, we find a very robust correlation (CC > 0.90) in log-log plots of F versus Ip over four decades of Ip. The ratio increases from western to eastern longitudes. From the value of Ip for a given event, F can be estimated to within a standard deviation of a factor of {≤} 2. Log-log plots of two studies are consistent with slopes of unity, but the third study shows plot slopes of { 10 MeV to {>} 100 MeV. This difference is not explained.

  20. Photodissociation of H2+ by intense chirped pulses - beyond the effect of pulse duration and peak power

    International Nuclear Information System (INIS)

    Lev, U; Prabhudesai, V; Natan, A; Bruner, B; Diner, A; Heber, O; Strasser, D; Schwalm, D; Silberberg, Y; Zajfman, D; Ben-Itzhak, I; Hua, J J; Esry, B D

    2009-01-01

    H 2 + photodissociation, induced by intense short laser pulses, was measured by a full 3D imaging system. We have conducted a series of experiments, in which we systematically changed the linear chirp, using a pulse shaper, and observed the kinetic energy release spectra(KER). Distinct differences in the KER spectra are observed both in peak positions and angular distribution for laser pulses with similar duration and intensity but opposite chirp sign.

  1. Splitting diffraction peak in different thickness LL-interferometer and determination of thickness of damaged layer induced by electron irradiation of plates

    International Nuclear Information System (INIS)

    Truni, K.G.; Sedrakyan, A.G.; Papoyan, A.A.; Bezirganyan, P.A.

    1988-01-01

    Amplitude of twice reflected beam is calculated analytically, oscillatory dependence of peak intensity in the centre of diffraction image on the small variations in thickness is shown. The expression, clearly binding the splitting value of diffraction peak with variation in thickness of the interferometer plates, is received. The effect of variation in thickness on the splitting value of focal line is studied experimentally in case of irradiation of the equal-arm Π-shaped interferometer blocks by fast electron flow, thickness of the originated damaged layers are determined

  2. 2-D Modelling of Long Period Variations of Galactic Cosmic Ray Intensity

    International Nuclear Information System (INIS)

    Siluszyk, M; Iskra, K; Alania, M

    2015-01-01

    A new two-dimensional (2-D) time dependent model describing long-period variations of the Galactic Cosmic Ray (GCR) intensity has been developed. New approximations for the changes of the magnitude B of the Interplanetary Magnetic Field (IMF), the tilt angle δ of the Heliospheric Neutral Sheet (HNS) and drift effects of the GCR particles have been included into the model. Moreover, temporal changes of the exponent γ expressing the power law - rigidity dependence of the amplitudes of the 11-year variation of the GCR intensity have been added. We show that changes of the expected GCR particle density precedes changes of the GCR intensity measured by the Moscow Neutron (MN) monitor by about 18 months. So ∼18 months can be taken as an effective delay time between the expected intensity caused by the combined influence of the changes of the parameters implemented in the time-dependent 2-D model and the GCR intensity measured by neutron monitors during the 21 cycle of solar activity. (paper)

  3. Binomial probability distribution model-based protein identification algorithm for tandem mass spectrometry utilizing peak intensity information.

    Science.gov (United States)

    Xiao, Chuan-Le; Chen, Xiao-Zhou; Du, Yang-Li; Sun, Xuesong; Zhang, Gong; He, Qing-Yu

    2013-01-04

    Mass spectrometry has become one of the most important technologies in proteomic analysis. Tandem mass spectrometry (LC-MS/MS) is a major tool for the analysis of peptide mixtures from protein samples. The key step of MS data processing is the identification of peptides from experimental spectra by searching public sequence databases. Although a number of algorithms to identify peptides from MS/MS data have been already proposed, e.g. Sequest, OMSSA, X!Tandem, Mascot, etc., they are mainly based on statistical models considering only peak-matches between experimental and theoretical spectra, but not peak intensity information. Moreover, different algorithms gave different results from the same MS data, implying their probable incompleteness and questionable reproducibility. We developed a novel peptide identification algorithm, ProVerB, based on a binomial probability distribution model of protein tandem mass spectrometry combined with a new scoring function, making full use of peak intensity information and, thus, enhancing the ability of identification. Compared with Mascot, Sequest, and SQID, ProVerB identified significantly more peptides from LC-MS/MS data sets than the current algorithms at 1% False Discovery Rate (FDR) and provided more confident peptide identifications. ProVerB is also compatible with various platforms and experimental data sets, showing its robustness and versatility. The open-source program ProVerB is available at http://bioinformatics.jnu.edu.cn/software/proverb/ .

  4. Wave propagation through disordered media without backscattering and intensity variations

    Institute of Scientific and Technical Information of China (English)

    Konstantinos G Makris; Andre Brandst(o)tter; Philipp Ambichl; Ziad H Musslimani; Stefan Rotter

    2017-01-01

    A fundamental manifestation of wave scattering in a disordered medium is the highly complex intensity pattern the waves acquire due to multi-path interference.Here we show that these intensity variations can be entirely suppressed by adding disorder-specific gain and loss components to the medium.The resulting constant-intensity waves in such non-Hermitian scattering landscapes are free of any backscattering and feature perfect transmission through the disorder.An experimental demonstration of these unique wave states is envisioned based on spatially modulated pump beams that can flexibly control the gain and loss components in an active medium.

  5. Variations in plasma wave intensity with distance along the electron foreshock boundary at Venus

    Science.gov (United States)

    Crawford, G. K.; Strangeway, R. J.; Russell, C. T.

    1991-01-01

    Plasma waves are observed in the solar wind upstream of the Venus bow shock by the Pioneer Venus Orbiter. These wave signatures occur during periods when the interplanetary magnetic field through the spacecraft position intersects the bow shock, thereby placing the spacecraft in the foreshock region. Wave intensity is analyzed as a function of distance along the electron foreshock boundary. It is found that the peak wave intensity may increase along the foreshock boundary from the tangent point to a maximum value at several Venus radii, then decrease in intensity with subsequent increase in distance. These observations could be associated with the instability process: the instability of the distribution function increasing with distance from the tangent point to saturation at the peak. Thermalization of the beam for distances beyond this point could reduce the distribution function instability resulting in weaker wave signatures.

  6. Effect of doping on the Raman lineshape and intensity of graphene

    Science.gov (United States)

    Casiraghi, Cinzia; Basko, Denis M.; Ferrari, Andrea C.

    2010-03-01

    Graphene can be doped by applying a gate voltage [1-2]. Doping strongly affects the G and 2D Raman peaks: i) the G peak upshifts for increasing doping, while its width decreases [1]; ii) the 2D upshifts for p-doping, while it downshifts for n-doping [2]. iii) the ratio between the 2D and G peaks intensity decreases for increasing doping [2]. The 2D intensity is strongly affected by the electron-electron scattering rate, which increases with doping [3]. Similar Raman peaks variations were observed for non-gated samples, as an effect of charged impurities [4]. Here we use the 2D peak intensity variation with doping to extract the electron-phonon scattering rate [3,5]. We note that in non-gated samples, where the Fermi level shift is induced by charged impurities, we can probe the 2D peak dependence much closer to the Dirac point than in gated ones [5]. We find an electron-phonon coupling scattering rate of 60 ps-1 at 2.41 eV excitation energy [3,5]. [4pt] [1] S. Pisana et al, Nature Mat. 6, 198 (2007)[0pt] [2] A. Das et al., Nature Nanotech. 3, 210 (2008)[0pt] [3] D. M. Basko et al. PRB 80, 165413 (2009)[0pt] [4] C. Casiraghi et al., APL 91, 233108 (2007)[0pt] [5] C. Casiraghi, arXiv:0908.4480

  7. Contribution of Myostatin gene polymorphisms to normal variation in lean mass, fat mass and peak BMD in Chinese male offspring

    Institute of Scientific and Technical Information of China (English)

    Hua YUE; Miao LI; Yu-juan LIU; Song-hua WU; Zhen-lin ZHANG; Jin-wei HE; Hao ZHANG; Chun WANG; Wei-wei HU; Jie-mei GU; Yao-hua KE; Wen-zhen FU; Yun-qiu HU

    2012-01-01

    Myostatin gene is a member of the transforming growth factor-β (TGF-β) family that negatively regulates skeletal muscle growth.Genetic polymorphisms in Myostatin were found to be associated with the peak bone mineral density (BMD) in Chinese women.The purpose of this study was to investigate whether Myostatin played a role in the normal variation in peak BMD,lean mass (LM),and fat mass (FM) of Chinese men.Methods:Four hundred male-offspring nuclear families of Chinese Han ethnic group were recruited.Anthropometric measurements,includingthe peak BMD,body LM and FM were measured using dual-energy X-ray absorptiometry (DXA).The single nucleotide polymorphisms (SNPs) studied were tag-SNPs selected by sequencing.Both rs2293284 and +2278G>A were genotyped using TaqMan assay,and rs3791783 was genotyped with PCR-restriction fragment length polymorphism (RFLP) analysis.The associations of the SNPs with anthropometfic variations were analyzed using the quantitative transmission disequilibrium test (QTDT).Results:Using QTDT to detect within-family associations,neither single SNP nor haplotype was found to be associated with peak BMD at any bone site.However,rs3791783 was found to be significantly associated with fat mass of the trunk (P<0.001).Moreover,for within-family associations,haplotypes AGG,AAA,and TGG were found to be significantly associated with the trunk fat mass (all P<0.001).Conclusion:Our results suggest that genetic variation within Myostatin may play a role in regulating the variation in fat mass in Chinese males.Additionally,the Myostatin gene may be a candidate that determines body fat mass in Chinese men.

  8. Variation of photon intensities in transmitted photon spectra of 60Co as a function of dimensions of a soil medium

    International Nuclear Information System (INIS)

    Singh, Charanjeet; Sidhu, Gurdeep S.; Kumar, Ashok; Singh, Tejbir; Singh, Parjit S.; Mudahar, Gurmel S.

    2005-01-01

    The transmitted photon spectra of a point gamma-ray source of 60 Co have been measured through the longitudinal and transverse dimensions of a soil medium. The simultaneous effect of longitudinal and transverse thicknesses has been studied on the intensity of an appeared multiple-scatter peak in the soft part of the spectrum. The intensity of peak decreases exponentially with the increase of longitudinal thickness of soil medium whereas a reversal of the trend of multiple-scatter peak intensity with the transverse thickness observed as longitudinal dimension increases

  9. Long-term variations of cosmic ray intensity

    International Nuclear Information System (INIS)

    Dergachev, V.A.; Kocharov, G.E.; Ostryakov, V.M.

    1982-01-01

    At the present time we know only one possibility to reconstruct the Cosmic Ray intensity in the past. This possibility is connected with the measurements of radiocarbon abundance in the dendrochronologically dated wood samples. As the experiments carried out with the help of spacecrafts, balloons and ground apparatus show the Galactic Cosmic Ray flux essentially varies on a short time scales. The variations are caused by different astrophysical and geophysical phenomena. 14 C isotope allows us to investigate these reasons on a more long time interval in comparison with direct observational possibilities

  10. Derivation from first principles of the statistical distribution of the mass peak intensities of MS data.

    Science.gov (United States)

    Ipsen, Andreas

    2015-02-03

    Despite the widespread use of mass spectrometry (MS) in a broad range of disciplines, the nature of MS data remains very poorly understood, and this places important constraints on the quality of MS data analysis as well as on the effectiveness of MS instrument design. In the following, a procedure for calculating the statistical distribution of the mass peak intensity for MS instruments that use analog-to-digital converters (ADCs) and electron multipliers is presented. It is demonstrated that the physical processes underlying the data-generation process, from the generation of the ions to the signal induced at the detector, and on to the digitization of the resulting voltage pulse, result in data that can be well-approximated by a Gaussian distribution whose mean and variance are determined by physically meaningful instrumental parameters. This allows for a very precise understanding of the signal-to-noise ratio of mass peak intensities and suggests novel ways of improving it. Moreover, it is a prerequisite for being able to address virtually all data analytical problems in downstream analyses in a statistically rigorous manner. The model is validated with experimental data.

  11. Soliton-induced nonlocal resonances observed through high-intensity tunable spectrally compressed second-harmonic peaks

    DEFF Research Database (Denmark)

    Zhou, Binbin; Guo, Hairun; Bache, Morten

    2014-01-01

    Experimental data of femtosecond thick-crystal second-harmonic generation show that when tuning away from phase matching, a dominating narrow spectral peak appears in the second harmonic that can be tuned over hundreds of nanometers by changing the phase-mismatch parameter. Traditional theory...... and the nonlocal theory indirectly proves that we have observed a soliton-induced nonlocal resonance. The soliton exists in the self-defocusing regime of the cascaded nonlinear interaction and in the normal dispersion regime of the crystal, and needs high input intensities to become excited....

  12. Photodissociation of H{sub 2}{sup +} by intense chirped pulses - beyond the effect of pulse duration and peak power

    Energy Technology Data Exchange (ETDEWEB)

    Lev, U; Prabhudesai, V; Natan, A; Bruner, B; Diner, A; Heber, O; Strasser, D; Schwalm, D; Silberberg, Y; Zajfman, D [Faculty of Physics, Weizmann Institute of Science, Rehovot 76100 (Israel); Ben-Itzhak, I; Hua, J J; Esry, B D, E-mail: uri.lev@Weizmann.ac.i [Department of Physics, Kansas State University, Manhattan, KS 66506 (United States)

    2009-11-01

    H{sub 2}{sup +} photodissociation, induced by intense short laser pulses, was measured by a full 3D imaging system. We have conducted a series of experiments, in which we systematically changed the linear chirp, using a pulse shaper, and observed the kinetic energy release spectra(KER). Distinct differences in the KER spectra are observed both in peak positions and angular distribution for laser pulses with similar duration and intensity but opposite chirp sign.

  13. Climate change is projected to have severe impacts on the frequency and intensity of peak electricity demand across the United States.

    Science.gov (United States)

    Auffhammer, Maximilian; Baylis, Patrick; Hausman, Catherine H

    2017-02-21

    It has been suggested that climate change impacts on the electric sector will account for the majority of global economic damages by the end of the current century and beyond [Rose S, et al. (2014) Understanding the Social Cost of Carbon: A Technical Assessment ]. The empirical literature has shown significant increases in climate-driven impacts on overall consumption, yet has not focused on the cost implications of the increased intensity and frequency of extreme events driving peak demand, which is the highest load observed in a period. We use comprehensive, high-frequency data at the level of load balancing authorities to parameterize the relationship between average or peak electricity demand and temperature for a major economy. Using statistical models, we analyze multiyear data from 166 load balancing authorities in the United States. We couple the estimated temperature response functions for total daily consumption and daily peak load with 18 downscaled global climate models (GCMs) to simulate climate change-driven impacts on both outcomes. We show moderate and heterogeneous changes in consumption, with an average increase of 2.8% by end of century. The results of our peak load simulations, however, suggest significant increases in the intensity and frequency of peak events throughout the United States, assuming today's technology and electricity market fundamentals. As the electricity grid is built to endure maximum load, our findings have significant implications for the construction of costly peak generating capacity, suggesting additional peak capacity costs of up to 180 billion dollars by the end of the century under business-as-usual.

  14. Relative importance of precipitation frequency and intensity in inter-annual variation of precipitation in Singapore during 1980-2013

    Science.gov (United States)

    Li, Xin; Babovic, Vladan

    2017-04-01

    Observed studies on inter-annual variation of precipitation provide insight into the response of precipitation to anthropogenic climate change and natural climate variability. Inter-annual variation of precipitation results from the concurrent variations of precipitation frequency and intensity, understanding of the relative importance of frequency and intensity in the variability of precipitation can help fathom its changing properties. Investigation of the long-term changes of precipitation schemes has been extensively carried out in many regions across the world, however, detailed studies of the relative importance of precipitation frequency and intensity in inter-annual variation of precipitation are still limited, especially in the tropics. Therefore, this study presents a comprehensive framework to investigate the inter-annual variation of precipitation and the dominance of precipitation frequency and intensity in a tropical urban city-state, Singapore, based on long-term (1980-2013) daily precipitation series from 22 rain gauges. First, an iterative Mann-Kendall trend test method is applied to detect long-term trends in precipitation total, frequency and intensity at both annual and seasonal time scales. Then, the relative importance of precipitation frequency and intensity in inducing the inter-annual variation of wet-day precipitation total is analyzed using a dominance analysis method based on linear regression. The results show statistically significant upward trends in wet-day precipitation total, frequency and intensity at annual time scale, however, these trends are not evident during the monsoon seasons. The inter-annual variation of wet-day precipitation is mainly dominated by precipitation intensity for most of the stations at annual time scale and during the Northeast monsoon season. However, during the Southwest monsoon season, the inter-annual variation of wet-day precipitation is mainly dominated by precipitation frequency. These results have

  15. Bayesian hierarchical model for variations in earthquake peak ground acceleration within small-aperture arrays

    KAUST Repository

    Rahpeyma, Sahar

    2018-04-17

    Knowledge of the characteristics of earthquake ground motion is fundamental for earthquake hazard assessments. Over small distances, relative to the source–site distance, where uniform site conditions are expected, the ground motion variability is also expected to be insignificant. However, despite being located on what has been characterized as a uniform lava‐rock site condition, considerable peak ground acceleration (PGA) variations were observed on stations of a small‐aperture array (covering approximately 1 km2) of accelerographs in Southwest Iceland during the Ölfus earthquake of magnitude 6.3 on May 29, 2008 and its sequence of aftershocks. We propose a novel Bayesian hierarchical model for the PGA variations accounting separately for earthquake event effects, station effects, and event‐station effects. An efficient posterior inference scheme based on Markov chain Monte Carlo (MCMC) simulations is proposed for the new model. The variance of the station effect is certainly different from zero according to the posterior density, indicating that individual station effects are different from one another. The Bayesian hierarchical model thus captures the observed PGA variations and quantifies to what extent the source and recording sites contribute to the overall variation in ground motions over relatively small distances on the lava‐rock site condition.

  16. Bayesian hierarchical model for variations in earthquake peak ground acceleration within small-aperture arrays

    KAUST Repository

    Rahpeyma, Sahar; Halldorsson, Benedikt; Hrafnkelsson, Birgir; Jonsson, Sigurjon

    2018-01-01

    Knowledge of the characteristics of earthquake ground motion is fundamental for earthquake hazard assessments. Over small distances, relative to the source–site distance, where uniform site conditions are expected, the ground motion variability is also expected to be insignificant. However, despite being located on what has been characterized as a uniform lava‐rock site condition, considerable peak ground acceleration (PGA) variations were observed on stations of a small‐aperture array (covering approximately 1 km2) of accelerographs in Southwest Iceland during the Ölfus earthquake of magnitude 6.3 on May 29, 2008 and its sequence of aftershocks. We propose a novel Bayesian hierarchical model for the PGA variations accounting separately for earthquake event effects, station effects, and event‐station effects. An efficient posterior inference scheme based on Markov chain Monte Carlo (MCMC) simulations is proposed for the new model. The variance of the station effect is certainly different from zero according to the posterior density, indicating that individual station effects are different from one another. The Bayesian hierarchical model thus captures the observed PGA variations and quantifies to what extent the source and recording sites contribute to the overall variation in ground motions over relatively small distances on the lava‐rock site condition.

  17. RELATIONSHIP OF AIRWAY HYPERRESPONSIVENESS TO RESPIRATORY SYMPTOMS AND DIURNAL PEAK FLOW VARIATION IN PATIENTS WITH OBSTRUCTIVE LUNG-DISEASE

    NARCIS (Netherlands)

    BRAND, PLP; POSTMA, DS; KERSTJENS, HAM; KOETER, GH

    This study reports on the relationship of airway hyperresponsiveness (AH) with respiratory symptoms and diurnal peak flow expiratory (PEF) variation in 221 hyperresponsive patients with moderately severe airways obstruction. The disease was in a stable phase in all patients. Closely adhering to the

  18. Automated Peak Picking and Peak Integration in Macromolecular NMR Spectra Using AUTOPSY

    Science.gov (United States)

    Koradi, Reto; Billeter, Martin; Engeli, Max; Güntert, Peter; Wüthrich, Kurt

    1998-12-01

    A new approach for automated peak picking of multidimensional protein NMR spectra with strong overlap is introduced, which makes use of the program AUTOPSY (automatedpeak picking for NMRspectroscopy). The main elements of this program are a novel function for local noise level calculation, the use of symmetry considerations, and the use of lineshapes extracted from well-separated peaks for resolving groups of strongly overlapping peaks. The algorithm generates peak lists with precise chemical shift and integral intensities, and a reliability measure for the recognition of each peak. The results of automated peak picking of NOESY spectra with AUTOPSY were tested in combination with the combined automated NOESY cross peak assignment and structure calculation routine NOAH implemented in the program DYANA. The quality of the resulting structures was found to be comparable with those from corresponding data obtained with manual peak picking.

  19. Spatiotemporal phenological changes in fall foliage peak coloration in deciduous forest and the responses to climatic variation

    Science.gov (United States)

    Xie, Y.; Wilson, A. M.

    2017-12-01

    Plant phenology studies typically focus on the beginning and end of the growing season in temperate forests. We know too little about fall foliage peak coloration, which is a bioindicator of plant response in autumn to environmental changes, an important visual cue in fall associated with animal activities, and a key element in fall foliage ecotourism. Spatiotemporal changes in timing of fall foliage peak coloration of temperate forests and the associated environmental controls are not well understood. In this study, we examined multiple color indices to estimate Land Surface Phenology (LSP) of fall foliage peak coloration of deciduous forest in the northeastern USA using Moderate Resolution Imaging Spectroradiometer (MODIS) daily imagery from 2000 to 2015. We used long term phenology ground observations to validate our estimated LSP, and found that Visible Atmospherically Resistant Index (VARI) and Plant Senescence Reflectance Index (PSRI) were good metrics to estimate peak and end of leaf coloration period of deciduous forest. During the past 16 years, the length of period with peak fall foliage color of deciduous forest at southern New England and northern Appalachian forests regions became longer (0.3 7.7 days), mainly driven by earlier peak coloration. Northern New England, southern Appalachian forests and Ozark and Ouachita mountains areas had shorter period (‒0.2 ‒9.2 days) mainly due to earlier end of leaf coloration. Changes in peak and end of leaf coloration not only were associated with changing temperature in spring and fall, but also to drought and heat in summer, and heavy precipitation in both summer and fall. The associations between leaf peak coloration phenology and climatic variations were not consistent among ecoregions. Our findings suggested divergent change patterns in fall foliage peak coloration phenology in deciduous forests, and improved our understanding in the environmental control on timing of fall foliage color change.

  20. The peak in neutron powder diffraction

    International Nuclear Information System (INIS)

    Laar, B. van; Yelon, W.B.

    1984-01-01

    For the application of Rietveld profile analysis to neutron powder diffraction data a precise knowledge of the peak profile, in both shape and position, is required. The method now in use employs a Gaussian shaped profile with a semi-empirical asymmetry correction for low-angle peaks. The integrated intensity is taken to be proportional to the classical Lorentz factor calculated for the X-ray case. In this paper an exact expression is given for the peak profile based upon the geometrical dimensions of the diffractometer. It is shown that the asymmetry of observed peaks is well reproduced by this expression. The angular displacement of the experimental profile with respect to the nominal Bragg angle value is larger than expected. Values for the correction to the classical Lorentz factor for the integrated intensity are given. The exact peak profile expression has been incorporated into a Rietveld profile analysis refinement program. (Auth.)

  1. The geomorphic structure of the runoff peak

    Directory of Open Access Journals (Sweden)

    R. Rigon

    2011-06-01

    Full Text Available This paper develops a theoretical framework to investigate the core dependence of peak flows on the geomorphic properties of river basins. Based on the theory of transport by travel times, and simple hydrodynamic characterization of floods, this new framework invokes the linearity and invariance of the hydrologic response to provide analytical and semi-analytical expressions for peak flow, time to peak, and area contributing to the peak runoff. These results are obtained for the case of constant-intensity hyetograph using the Intensity-Duration-Frequency (IDF curves to estimate extreme flow values as a function of the rainfall return period. Results show that, with constant-intensity hyetographs, the time-to-peak is greater than rainfall duration and usually shorter than the basin concentration time. Moreover, the critical storm duration is shown to be independent of rainfall return period as well as the area contributing to the flow peak. The same results are found when the effects of hydrodynamic dispersion are accounted for. Further, it is shown that, when the effects of hydrodynamic dispersion are negligible, the basin area contributing to the peak discharge does not depend on the channel velocity, but is a geomorphic propriety of the basin. As an example this framework is applied to three watersheds. In particular, the runoff peak, the critical rainfall durations and the time to peak are calculated for all links within a network to assess how they increase with basin area.

  2. Latitudinal variation of the polar cusp during a geomagnetic storm

    International Nuclear Information System (INIS)

    Meng, C.

    1982-01-01

    Large amplitude latitudinal variation of the polar cusp position was observed during the intense geomagnetic storm of 15--16 February 1980. The observation of the polar cusp, identified as the region of intense but extremely soft electron precipitation, was made by two nearly noon-midnight orbit DMSP satellites over both northern and southern hemispheres. The latitudinal shift of the polar cusp is observed to be related to the intensity variation of the ring current indicated by the hourly Dst values. The polar cusp region moved from its normal location at approx.76 0 gm lat down to approx.62 0 gm lat at the peak of this storm. This movement took about 5 hours and was detected over both hemispheres. A drastic variation in the width of the cusp region was also observed; it is very narrow (approx.1 0 ) during the equatorial shift and expands to > or approx. =5 0 during the poleward recovery. Variation of the polar cusp latitude with that of the Dst index was also seen during the period before the intense storm

  3. Automation of peak-tracking analysis of stepwise perturbed NMR spectra

    Energy Technology Data Exchange (ETDEWEB)

    Banelli, Tommaso; Vuano, Marco [Università di Udine, Dipartimento di Area Medica (Italy); Fogolari, Federico [INBB (Italy); Fusiello, Andrea [Università di Udine, Dipartimento Politecnico di Ingegneria e Architettura (Italy); Esposito, Gennaro [INBB (Italy); Corazza, Alessandra, E-mail: alessandra.corazza@uniud.it [Università di Udine, Dipartimento di Area Medica (Italy)

    2017-02-15

    We describe a new algorithmic approach able to automatically pick and track the NMR resonances of a large number of 2D NMR spectra acquired during a stepwise variation of a physical parameter. The method has been named Trace in Track (TinT), referring to the idea that a gaussian decomposition traces peaks within the tracks recognised through 3D mathematical morphology. It is capable of determining the evolution of the chemical shifts, intensity and linewidths of each tracked peak.The performances obtained in term of track reconstruction and correct assignment on realistic synthetic spectra were high above 90% when a noise level similar to that of experimental data were considered. TinT was applied successfully to several protein systems during a temperature ramp in isotope exchange experiments. A comparison with a state-of-the-art algorithm showed promising results for great numbers of spectra and low signal to noise ratios, when the graduality of the perturbation is appropriate. TinT can be applied to different kinds of high throughput chemical shift mapping experiments, with quasi-continuous variations, in which a quantitative automated recognition is crucial.

  4. Effect of high-intensity training versus moderate training on peak oxygen uptake and chronotropic response in heart transplant recipients

    DEFF Research Database (Denmark)

    Dall, C H; Snoer, M; Christensen, S

    2014-01-01

    In heart transplant (HTx) recipients, there has been reluctance to recommend high-intensity interval training (HIIT) due to denervation and chronotropic impairment of the heart. We compared the effects of 12 weeks' HIIT versus continued moderate exercise (CON) on exercise capacity and chronotropic...... response in stable HTx recipients >12 months after transplantation in a randomized crossover trial. The study was completed by 16 HTx recipients (mean age 52 years, 75% males). Baseline peak oxygen uptake (VO2peak ) was 22.9 mL/kg/min. HIIT increased VO2peak by 4.9 ± 2.7 mL/min/kg (17%) and CON by 2.6 ± 2.......2 mL/kg/min (10%) (significantly higher in HIIT; p HIIT, systolic blood pressure decreased significantly (p = 0.037) with no significant change in CON (p = 0.241; between group difference p = 0.027). Peak heart rate (HRpeak ) increased significantly by 4.3 beats per minute (p = 0...

  5. EXTINCTION AND POLYCYCLIC AROMATIC HYDROCARBON INTENSITY VARIATIONS ACROSS THE H II REGION IRAS 12063-6259

    Energy Technology Data Exchange (ETDEWEB)

    Stock, D. J.; Peeters, E.; Otaguro, J. N. [Department of Physics and Astronomy, University of Western Ontario, London, ON N6A 3K7 (Canada); Tielens, A. G. G. M. [Leiden Observatory, Leiden University, P.O. Box 9513, NL-2300 RA Leiden (Netherlands); Bik, A. [Max-Planck-Institut fuer Astronomie, Koenigstuhl 17, D-69117 Heidelberg (Germany)

    2013-07-01

    The spatial variations in polycyclic aromatic hydrocarbon (PAH) band intensities are normally attributed to the physical conditions of the emitting PAHs, however in recent years it has been suggested that such variations are caused mainly by extinction. To resolve this question, we have obtained near-infrared (NIR), mid-infrared (MIR), and radio observations of the compact H II region IRAS 12063-6259. We use these data to construct multiple independent extinction maps and also to measure the main PAH features (6.2, 7.7, 8.6, and 11.2 {mu}m) in the MIR. Three extinction maps are derived: the first using the NIR hydrogen lines and case B recombination theory; the second combining the NIR data with radio data; and the third making use of the Spitzer/IRS MIR observations to measure the 9.8 {mu}m silicate absorption feature using the Spoon method and PAHFIT (as the depth of this feature can be related to overall extinction). The silicate absorption over the bright, southern component of IRAS 12063-6259 is almost absent while the other methods find significant extinction. While such breakdowns of the relationship between the NIR extinction and the 9.8 {mu}m absorption have been observed in molecular clouds, they have never been observed for H II regions. We then compare the PAH intensity variations in the Spitzer/IRS data after dereddening to those found in the original data. It was found that in most cases, the PAH band intensity variations persist even after dereddening, implying that extinction is not the main cause of the PAH band intensity variations.

  6. Effect of variations in rainfall intensity on slope stability in Singapore

    Directory of Open Access Journals (Sweden)

    Christofer Kristo

    2017-12-01

    Full Text Available Numerous scientific evidence has given credence to the true existence and deleterious impacts of climate change. One aspect of climate change is the variations in rainfall patterns, which affect the flux boundary condition across ground surface. A possible disastrous consequence of this change is the occurrence of rainfall-induced slope failures. This paper aims to investigate the variations in rainfall patterns in Singapore and its effect on slope stability. Singapore's historical rainfall data from Seletar and Paya Lebar weather stations for the period of 1985–2009 were obtained and analysed by duration using linear regression. A general increasing trend was observed in both weather stations, with a possible shift to longer duration rainfall events, despite being statistically insignificant according to the Mann-Kendall test. Using the derived trends, projected rainfall intensities in 2050 and 2100 were used in the seepage and slope stability analyses performed on a typical residual soil slope in Singapore. A significant reduction in factor of safety was observed in the next 50 years, with only a marginal decrease in factor of safety in the subsequent 50 years. This indicates a possible detrimental effect of variations in rainfall patterns on slope stability in Singapore, especially in the next 50 years. The statistical analyses on rainfall data from Seletar and Paya Lebar weather stations for the period of 1985–2009 indicated that rainfall intensity tend to increase over the years, with a possible shift to longer duration rainfall events in the future. The stability analyses showed a significant decrease in factor of safety from 2003 to 2050 due to increase in rainfall intensity, suggesting that a climate change might have existed beyond 2009 with possibly detrimental effects to slope stability. Keywords: Climate change, Rainfall, Seepage, Slope stability

  7. Colour based fire detection method with temporal intensity variation filtration

    International Nuclear Information System (INIS)

    Trambitckii, K; Musalimov, V; Anding, K; Linß, G

    2015-01-01

    Development of video, computing technologies and computer vision gives a possibility of automatic fire detection on video information. Under that project different algorithms was implemented to find more efficient way of fire detection. In that article colour based fire detection algorithm is described. But it is not enough to use only colour information to detect fire properly. The main reason of this is that in the shooting conditions may be a lot of things having colour similar to fire. A temporary intensity variation of pixels is used to separate them from the fire. These variations are averaged over the series of several frames. This algorithm shows robust work and was realised as a computer program by using of the OpenCV library

  8. Colour based fire detection method with temporal intensity variation filtration

    Science.gov (United States)

    Trambitckii, K.; Anding, K.; Musalimov, V.; Linß, G.

    2015-02-01

    Development of video, computing technologies and computer vision gives a possibility of automatic fire detection on video information. Under that project different algorithms was implemented to find more efficient way of fire detection. In that article colour based fire detection algorithm is described. But it is not enough to use only colour information to detect fire properly. The main reason of this is that in the shooting conditions may be a lot of things having colour similar to fire. A temporary intensity variation of pixels is used to separate them from the fire. These variations are averaged over the series of several frames. This algorithm shows robust work and was realised as a computer program by using of the OpenCV library.

  9. Origin of transient cosmic ray intensity variations

    International Nuclear Information System (INIS)

    Duggal, S.P.; Pomerantz, M.A.

    1977-01-01

    A new approach to determining the solar progenitor of transient cosmic ray intensity variations has revealed that in a statistical sense, solar flares, heretofore regarded as the predominant source of the modulation, actually do not precede the reduction in flux observed at earth. Superposed epoch analysis of the cosmic ray data with respect to the time of occurrence of all 379 solar flares of importance (Imp) < or =2 observed during solar cycle 20 (1964-1974 inclusive) shows that the onset of a decrease in the composite nucleonic intensity at polar stations occurs prior to the zero day (i.e., time of the flare) well before the arrival in the vicinity of earth of the associated solar plasma. The statistical significance of this result is confirmed by comparing the pooled variance determined from Chree analysis of an equal number of random epochs with that of the curve representing the flare epochs. Subdivision of the latter into three groups according to the heliographic longitude of the flares shows that whereas eastern flares might be associated with cosmic ray decreases, central (30degree to -30degree) and western flares cannot be thus related. A similar analysis of all flares of Imp< or =2 that occurred in a selected set of 24 extraordinary flare-rich active centers during 1964--1974 confirms these results and shows that the observed cosmic ray intensity decrease is, in fact, associated with the central meridian passage ( +- 1 day) of the active regions. Thus earlier conclusions concerning relationships between the heliolongitude of flares and their apparent effectiveness in producing Forbush decreases require reevaluation. The specific feature associated with solar active centers that is actually the principal source of transient modulations remanins to be identified

  10. Case studies of the storm time variation of the polar cusp

    International Nuclear Information System (INIS)

    Meng, C.

    1983-01-01

    The latitudinal variations of the polar cusp region were examined during three intense geomagnetic storms. The variations were compared with the intensity of storm time ring current inferred from the Dst index, with the magnitude of the north-south component B/sub z/ of the interplanetary magnetic field and with substorm activity. The common feature is that the rapid equatorward shift occurred during the increase of the ring current growth and during the southward turning of the interplanetary magnetic field orientation. The equatorwardmost latitude of the cusp was reached before the peak of the ring current intensity, by a few to several hours, coinciding with the occurrence of the largest magnitude of the southward interplanetary magnetic field component. However, details of the polar cusp latitudinal movement differ from storm to storm. During the three storms studied, the poleward recovery commenced at the peak magnitude of the negative IMF B/sub z/ component, but the recovery proceeded without a clear relation to variations of the interplanetary B/sub z/ component, to the ring current intensity, or to the substorm activity. The lowest cusp latitude observed was at approx.61.7 0 , and the magnitude of this shift seems to be related to the magnitudes of -B/sub z/. It is further observed that the approximate rates of the cusp macroscopic equatorward and poleward movements are about 3 0 and 1.5 0 per hour, respectively

  11. EXTINCTION AND POLYCYCLIC AROMATIC HYDROCARBON INTENSITY VARIATIONS ACROSS THE H II REGION IRAS 12063–6259

    International Nuclear Information System (INIS)

    Stock, D. J.; Peeters, E.; Otaguro, J. N.; Tielens, A. G. G. M.; Bik, A.

    2013-01-01

    The spatial variations in polycyclic aromatic hydrocarbon (PAH) band intensities are normally attributed to the physical conditions of the emitting PAHs, however in recent years it has been suggested that such variations are caused mainly by extinction. To resolve this question, we have obtained near-infrared (NIR), mid-infrared (MIR), and radio observations of the compact H II region IRAS 12063–6259. We use these data to construct multiple independent extinction maps and also to measure the main PAH features (6.2, 7.7, 8.6, and 11.2 μm) in the MIR. Three extinction maps are derived: the first using the NIR hydrogen lines and case B recombination theory; the second combining the NIR data with radio data; and the third making use of the Spitzer/IRS MIR observations to measure the 9.8 μm silicate absorption feature using the Spoon method and PAHFIT (as the depth of this feature can be related to overall extinction). The silicate absorption over the bright, southern component of IRAS 12063–6259 is almost absent while the other methods find significant extinction. While such breakdowns of the relationship between the NIR extinction and the 9.8 μm absorption have been observed in molecular clouds, they have never been observed for H II regions. We then compare the PAH intensity variations in the Spitzer/IRS data after dereddening to those found in the original data. It was found that in most cases, the PAH band intensity variations persist even after dereddening, implying that extinction is not the main cause of the PAH band intensity variations.

  12. Cluster-assisted multiple ionization of methyl iodide by a nanosecond laser: Influence of laser intensity on the kinetic energy and peak profile of multicharged ions

    International Nuclear Information System (INIS)

    Wen Lihua; Li Haiyang; Luo Xiaolin; Niu Dongmei; Xiao Xue; Wang Bin; Liang Feng; Hou Keyong; Shao Shiyong

    2006-01-01

    The dependences of kinetic energies and peak profiles of multicharged ions of I q+ (q = 2-3) and C 2+ on the laser intensity have been studied in detail by time-of-flight mass spectrometry, those multicharged ions are produced by irradiation of methyl iodide cluster beam with a nanosecond 532 nm Nd-YAG laser. Our experiments show that the kinetic energies released of multicharged ions increase linearly with the laser intensity in the range of 3 x 10 9 -2 x 10 11 W/cm 2 . The peaks of multicharged ions are split to forward ions and backward ions, and the ratio of the backward ions to forward ions decreases exponentially with laser intensity. The decreasing of backward ions is probably due to Coulomb scattering by the heavier I + ions when they turn around through the laser focus point. The linear dependence of kinetic energy of multicharged ions on laser intensity is interpreted by the ionization mechanism, in which the laser induced inverse bremsstrahlung heating of electron is the rate-limiting step

  13. Photon energy dependent intensity variations observed in Auger spectra of free argon clusters

    International Nuclear Information System (INIS)

    Lundwall, M; Lindblad, A; Bergersen, H; Rander, T; Oehrwall, G; Tchaplyguine, M; Peredkov, S; Svensson, S; Bjoerneholm, O

    2006-01-01

    Photon energy dependent intensity variations are experimentally observed in the L 2,3 M 2,3 M 2,3 Auger spectra of argon clusters. Two cluster sizes are examined in the present study. Extrinsic scattering effects, both elastic and inelastic, involving the photoelectron are discussed and suggested as the explanation of the variations in the Auger signal. The atoms in the first few coordination shells surrounding the core-ionized atom are proposed to be the main targets for the scattering processes

  14. Variations of interplanetary parameters and cosmic-ray intensities

    International Nuclear Information System (INIS)

    Geranios, A.

    1980-01-01

    Observations of cosmic ray intensity depressions by earth bound neutron monitors and measurements of interplanetary parameter's variations aboard geocentric satellites in the period January 1972-July 1974 are analysed and grouped according to their correlation among them. From this analysis of about 30 cases it came out that the majority of the depressions correlates with the average propagation speed of interplanetary shocks as well as with the amplitude of the interplanetary magnetic field after the eruption of a solar flare. About one fourth of the events correlates with corotating fast solar wind streams. As the recovery time of the shock-related depressions depends strongly on the heliographic longitude of the causitive solar flare, it seems that the cosmic ray modulation region has a corotative-like feature. (Auth.)

  15. Characterizations of the diurnal shapes of OI 630.0 nm dayglow intensity variations: inferences

    Directory of Open Access Journals (Sweden)

    D. Chakrabarty

    2002-11-01

    Full Text Available Measurements of OI 630.0 nm thermospheric dayglow emission by means of the Dayglow Photometer (DGP at Mt. Abu (24.6° N, 73.7° E, dip lat 19.09° N, a station under the crest of Equatorial Ionization Anomaly (EIA, reveal day-to-day changes in the shapes of the diurnal profiles of dayglow intensity variations. These shapes have been characterized using the magnetometer data from equatorial and low-latitude stations. Substantial changes have been noticed in the shapes of the dayglow intensity variations between 10:00–15:00 IST (Indian Standard Time during the days when normal and counter electrojet events are present over the equator. It is found that the width (the time span corresponding to 0.8 times the maximum dayglow intensity of the diurnal profile has a linear relationship with the integrated electrojet strength. Occasional deviation from this linear relationship is attributed to the presence of substantial mean meridional wind.Key words. Ionosphere (equatorial ionosphere; ionosphere – atmosphere interactions; ionospheric disturbances

  16. Characterizations of the diurnal shapes of OI 630.0 nm dayglow intensity variations: inferences

    Directory of Open Access Journals (Sweden)

    D. Chakrabarty

    Full Text Available Measurements of OI 630.0 nm thermospheric dayglow emission by means of the Dayglow Photometer (DGP at Mt. Abu (24.6° N, 73.7° E, dip lat 19.09° N, a station under the crest of Equatorial Ionization Anomaly (EIA, reveal day-to-day changes in the shapes of the diurnal profiles of dayglow intensity variations. These shapes have been characterized using the magnetometer data from equatorial and low-latitude stations. Substantial changes have been noticed in the shapes of the dayglow intensity variations between 10:00–15:00 IST (Indian Standard Time during the days when normal and counter electrojet events are present over the equator. It is found that the width (the time span corresponding to 0.8 times the maximum dayglow intensity of the diurnal profile has a linear relationship with the integrated electrojet strength. Occasional deviation from this linear relationship is attributed to the presence of substantial mean meridional wind.

    Key words. Ionosphere (equatorial ionosphere; ionosphere – atmosphere interactions; ionospheric disturbances

  17. The environmental impacts of peaking at hydropower plants

    International Nuclear Information System (INIS)

    Halleraker, Jo Halvard

    2001-01-01

    A recent energy act in Norway allows hydropower plants to be operated so that hydro peaking is permitted. However, it is uncertain how fish react to the variations in discharge and depth that follow hydro peaking. SINTEF Energy Research is cooperating with other research institutions to investigate the consequences of these variations on the biota. Among the research tools is an aqua channel which is an indoor laboratory flume where fish behaviour can be studied in detail. It has been constructed to provide the hydropower industry and public authorities with means of better determining the effects of hydro peaking. (author)

  18. Validation of the Amsterdam Dynamic Facial Expression Set--Bath Intensity Variations (ADFES-BIV: A Set of Videos Expressing Low, Intermediate, and High Intensity Emotions.

    Directory of Open Access Journals (Sweden)

    Tanja S H Wingenbach

    Full Text Available Most of the existing sets of facial expressions of emotion contain static photographs. While increasing demand for stimuli with enhanced ecological validity in facial emotion recognition research has led to the development of video stimuli, these typically involve full-blown (apex expressions. However, variations of intensity in emotional facial expressions occur in real life social interactions, with low intensity expressions of emotions frequently occurring. The current study therefore developed and validated a set of video stimuli portraying three levels of intensity of emotional expressions, from low to high intensity. The videos were adapted from the Amsterdam Dynamic Facial Expression Set (ADFES and termed the Bath Intensity Variations (ADFES-BIV. A healthy sample of 92 people recruited from the University of Bath community (41 male, 51 female completed a facial emotion recognition task including expressions of 6 basic emotions (anger, happiness, disgust, fear, surprise, sadness and 3 complex emotions (contempt, embarrassment, pride that were expressed at three different intensities of expression and neutral. Accuracy scores (raw and unbiased (Hu hit rates were calculated, as well as response times. Accuracy rates above chance level of responding were found for all emotion categories, producing an overall raw hit rate of 69% for the ADFES-BIV. The three intensity levels were validated as distinct categories, with higher accuracies and faster responses to high intensity expressions than intermediate intensity expressions, which had higher accuracies and faster responses than low intensity expressions. To further validate the intensities, a second study with standardised display times was conducted replicating this pattern. The ADFES-BIV has greater ecological validity than many other emotion stimulus sets and allows for versatile applications in emotion research. It can be retrieved free of charge for research purposes from the

  19. Validation of the Amsterdam Dynamic Facial Expression Set--Bath Intensity Variations (ADFES-BIV): A Set of Videos Expressing Low, Intermediate, and High Intensity Emotions.

    Science.gov (United States)

    Wingenbach, Tanja S H; Ashwin, Chris; Brosnan, Mark

    2016-01-01

    Most of the existing sets of facial expressions of emotion contain static photographs. While increasing demand for stimuli with enhanced ecological validity in facial emotion recognition research has led to the development of video stimuli, these typically involve full-blown (apex) expressions. However, variations of intensity in emotional facial expressions occur in real life social interactions, with low intensity expressions of emotions frequently occurring. The current study therefore developed and validated a set of video stimuli portraying three levels of intensity of emotional expressions, from low to high intensity. The videos were adapted from the Amsterdam Dynamic Facial Expression Set (ADFES) and termed the Bath Intensity Variations (ADFES-BIV). A healthy sample of 92 people recruited from the University of Bath community (41 male, 51 female) completed a facial emotion recognition task including expressions of 6 basic emotions (anger, happiness, disgust, fear, surprise, sadness) and 3 complex emotions (contempt, embarrassment, pride) that were expressed at three different intensities of expression and neutral. Accuracy scores (raw and unbiased (Hu) hit rates) were calculated, as well as response times. Accuracy rates above chance level of responding were found for all emotion categories, producing an overall raw hit rate of 69% for the ADFES-BIV. The three intensity levels were validated as distinct categories, with higher accuracies and faster responses to high intensity expressions than intermediate intensity expressions, which had higher accuracies and faster responses than low intensity expressions. To further validate the intensities, a second study with standardised display times was conducted replicating this pattern. The ADFES-BIV has greater ecological validity than many other emotion stimulus sets and allows for versatile applications in emotion research. It can be retrieved free of charge for research purposes from the corresponding author.

  20. Local Times of Galactic Cosmic Ray Intensity Maximum and Minimum in the Diurnal Variation

    Directory of Open Access Journals (Sweden)

    Su Yeon Oh

    2006-06-01

    Full Text Available The Diurnal variation of galactic cosmic ray (GCR flux intensity observed by the ground Neutron Monitor (NM shows a sinusoidal pattern with the amplitude of 1sim 2 % of daily mean. We carried out a statistical study on tendencies of the local times of GCR intensity daily maximum and minimum. To test the influences of the solar activity and the location (cut-off rigidity on the distribution in the local times of maximum and minimum GCR intensity, we have examined the data of 1996 (solar minimum and 2000 (solar maximum at the low-latitude Haleakala (latitude: 20.72 N, cut-off rigidity: 12.91 GeV and the high-latitude Oulu (latitude: 65.05 N, cut-off rigidity: 0.81 GeV NM stations. The most frequent local times of the GCR intensity daily maximum and minimum come later about 2sim3 hours in the solar activity maximum year 2000 than in the solar activity minimum year 1996. Oulu NM station whose cut-off rigidity is smaller has the most frequent local times of the GCR intensity maximum and minimum later by 2sim3 hours from those of Haleakala station. This feature is more evident at the solar maximum. The phase of the daily variation in GCR is dependent upon the interplanetary magnetic field varying with the solar activity and the cut-off rigidity varying with the geographic latitude.

  1. Detection of the relationship between peak temperature and extreme precipitation

    Science.gov (United States)

    Yu, Y.; Liu, J.; Zhiyong, Y.

    2017-12-01

    Under the background of climate change and human activities, the characteristics and pattern of precipitation have changed significantly in many regions. As the political and cultural center of China, the structure and character of precipitation in Jingjinji District has varied dramatically in recent years. In this paper, the daily precipitation data throughout the period 1960-2013 are selected for analyzing the spatial-temporal variability of precipitation. The results indicate that the frequency and intensity of precipitation presents an increasing trend. Based on the precipitation data, the maximum, minimum and mean precipitation in different temporal and spatial scales is calculated respectively. The temporal and spatial variation of temperature is obtained by using statistical methods. The relationship between temperature and precipitation in different range is analyzed. The curve relates daily precipitation extremes with local temperatures has a peak structure, increasing at the low-medium range of temperature variations but decreasing at high temperatures. The relationship between extreme precipitation is stronger in downtown than that in suburbs.

  2. Variation in faecal water content may confound estimates of gastro-intestinal parasite intensity in wild African herbivores.

    Science.gov (United States)

    Turner, W C; Cizauskas, C A; Getz, W M

    2010-03-01

    Estimates of parasite intensity within host populations are essential for many studies of host-parasite relationships. Here we evaluated the seasonal, age- and sex-related variability in faecal water content for two wild ungulate species, springbok (Antidorcas marsupialis) and plains zebra (Equus quagga). We then assessed whether or not faecal water content biased conclusions regarding differences in strongyle infection rates by season, age or sex. There was evidence of significant variation in faecal water content by season and age for both species, and by sex in springbok. Analyses of faecal egg counts demonstrated that sex was a near-significant factor in explaining variation in strongyle parasite infection rates in zebra (P = 0.055) and springbok (P = 0.052) using wet-weight faecal samples. However, once these intensity estimates were re-scaled by the percent of dry matter in the faeces, sex was no longer a significant factor (zebra, P = 0.268; springbok, P = 0.234). These results demonstrate that variation in faecal water content may confound analyses and could produce spurious conclusions, as was the case with host sex as a factor in the analysis. We thus recommend that researchers assess whether water variation could be a confounding factor when designing and performing research using faecal indices of parasite intensity.

  3. Validation of the Amsterdam Dynamic Facial Expression Set – Bath Intensity Variations (ADFES-BIV): A Set of Videos Expressing Low, Intermediate, and High Intensity Emotions

    Science.gov (United States)

    Wingenbach, Tanja S. H.

    2016-01-01

    Most of the existing sets of facial expressions of emotion contain static photographs. While increasing demand for stimuli with enhanced ecological validity in facial emotion recognition research has led to the development of video stimuli, these typically involve full-blown (apex) expressions. However, variations of intensity in emotional facial expressions occur in real life social interactions, with low intensity expressions of emotions frequently occurring. The current study therefore developed and validated a set of video stimuli portraying three levels of intensity of emotional expressions, from low to high intensity. The videos were adapted from the Amsterdam Dynamic Facial Expression Set (ADFES) and termed the Bath Intensity Variations (ADFES-BIV). A healthy sample of 92 people recruited from the University of Bath community (41 male, 51 female) completed a facial emotion recognition task including expressions of 6 basic emotions (anger, happiness, disgust, fear, surprise, sadness) and 3 complex emotions (contempt, embarrassment, pride) that were expressed at three different intensities of expression and neutral. Accuracy scores (raw and unbiased (Hu) hit rates) were calculated, as well as response times. Accuracy rates above chance level of responding were found for all emotion categories, producing an overall raw hit rate of 69% for the ADFES-BIV. The three intensity levels were validated as distinct categories, with higher accuracies and faster responses to high intensity expressions than intermediate intensity expressions, which had higher accuracies and faster responses than low intensity expressions. To further validate the intensities, a second study with standardised display times was conducted replicating this pattern. The ADFES-BIV has greater ecological validity than many other emotion stimulus sets and allows for versatile applications in emotion research. It can be retrieved free of charge for research purposes from the corresponding author

  4. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors.

    Science.gov (United States)

    Ignee, Andre; Jedrejczyk, Maciej; Schuessler, Gudrun; Jakubowski, Wieslaw; Dietrich, Christoph F

    2010-01-01

    Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Videos sequences of 31 consecutive patients for at least 60s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10cm depths, whereas all other parameters showed only satisfying results at 4-6cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  5. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors

    Energy Technology Data Exchange (ETDEWEB)

    Ignee, Andre [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: andre.ignee@gmx.de; Jedrejczyk, Maciej [Department of Diagnostic Imaging, 2nd Division of Medical Faculty, Medical University, Ul. Kondratowicza 8, 03-242 Warsaw (Poland)], E-mail: mjedrzejczyk@interia.pl; Schuessler, Gudrun [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: gudrunschuessler@gmx.de; Jakubowski, Wieslaw [Department of Diagnostic Imaging, 2nd Division of Medical Faculty, Medical University, Ul. Kondratowicza 8, 03-242 Warsaw (Poland)], E-mail: ewajbmd@go2.pl; Dietrich, Christoph F. [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: christoph.dietrich@ckbm.de

    2010-01-15

    Introduction: Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Patients and methods: Videos sequences of 31 consecutive patients for at least 60 s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. Results: The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10 cm depths, whereas all other parameters showed only satisfying results at 4-6 cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. Discussion: (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4 cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6 cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves.

  6. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors

    International Nuclear Information System (INIS)

    Ignee, Andre; Jedrejczyk, Maciej; Schuessler, Gudrun; Jakubowski, Wieslaw; Dietrich, Christoph F.

    2010-01-01

    Introduction: Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Patients and methods: Videos sequences of 31 consecutive patients for at least 60 s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. Results: The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10 cm depths, whereas all other parameters showed only satisfying results at 4-6 cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. Discussion: (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4 cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6 cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves.

  7. Dependence of high order harmonics intensity on laser focal spot position in preformed plasma plumes

    International Nuclear Information System (INIS)

    Singhal, H.; Ganeev, R.; Naik, P. A.; Arora, V.; Chakravarty, U.; Gupta, P. D.

    2008-01-01

    The dependence of the high-order harmonic intensity on the laser focal spot position in laser produced plasma plumes is experimentally studied. High order harmonics up to the 59th order (λ∼13.5 nm) were generated by focusing 48 fs laser pulses from a Ti:sapphire laser system in silver plasma plume produced using 300 ps uncompressed laser radiation as the prepulse. The intensity of harmonics nearly vanished when the best focus was located in the plume center, whereas it peaked on either side with unequal intensity. The focal spot position corresponding to the peak harmonic intensity moved away from the plume center for higher order harmonics. The results are explained in terms of the variation of phase mismatch between the driving laser beam and harmonics radiation produced, relativistic drift of electrons, and defocusing effect due to radial ionization gradient in the plasma for different focal spot positions

  8. Secular variation of cosmic ray intensity recorded in the radiocarbon concentration of tree rings

    International Nuclear Information System (INIS)

    Kigoshi, K.

    1978-01-01

    Study of the secular variations of cosmic ray intensity on the basis of the secular variations of atmospheric radiocarbon concentration in 8000 years is considered. The data on the radiocarbon concentration is received by three laboratories using the dendrochronologically dated tree ring samples. In order to use the data the variations due to geochemical process must be eliminated. From this point of view the climatic effect on the atmospheric radiocarbon concenttration is estimated using the data on sunspot number and global surface temperature during 1650-1800 y. The barge influence of climate on the atmospheric radiocarbon concentration syggests the small contribution of change of radiocarbon production rate to the short-period fluctuations in the atmospheric radiocarbon concentration. Elimination of variations caused by climate and sunspot activities from the variations in atmospheric radiocarbon concentration gives a long-term scale of its concentration which agrees well to the observed paleo-geomagnetic data

  9. Towards highest peak intensities for ultra-short MeV-range ion bunches

    Science.gov (United States)

    Busold, Simon; Schumacher, Dennis; Brabetz, Christian; Jahn, Diana; Kroll, Florian; Deppert, Oliver; Schramm, Ulrich; Cowan, Thomas E.; Blažević, Abel; Bagnoud, Vincent; Roth, Markus

    2015-01-01

    A laser-driven, multi-MeV-range ion beamline has been installed at the GSI Helmholtz center for heavy ion research. The high-power laser PHELIX drives the very short (picosecond) ion acceleration on μm scale, with energies ranging up to 28.4 MeV for protons in a continuous spectrum. The necessary beam shaping behind the source is accomplished by applying magnetic ion lenses like solenoids and quadrupoles and a radiofrequency cavity. Based on the unique beam properties from the laser-driven source, high-current single bunches could be produced and characterized in a recent experiment: At a central energy of 7.8 MeV, up to 5 × 108 protons could be re-focused in time to a FWHM bunch length of τ = (462 ± 40) ps via phase focusing. The bunches show a moderate energy spread between 10% and 15% (ΔE/E0 at FWHM) and are available at 6 m distance to the source und thus separated from the harsh laser-matter interaction environment. These successful experiments represent the basis for developing novel laser-driven ion beamlines and accessing highest peak intensities for ultra-short MeV-range ion bunches. PMID:26212024

  10. Towards highest peak intensities for ultra-short MeV-range ion bunches

    Science.gov (United States)

    Busold, Simon; Schumacher, Dennis; Brabetz, Christian; Jahn, Diana; Kroll, Florian; Deppert, Oliver; Schramm, Ulrich; Cowan, Thomas E.; Blažević, Abel; Bagnoud, Vincent; Roth, Markus

    2015-07-01

    A laser-driven, multi-MeV-range ion beamline has been installed at the GSI Helmholtz center for heavy ion research. The high-power laser PHELIX drives the very short (picosecond) ion acceleration on μm scale, with energies ranging up to 28.4 MeV for protons in a continuous spectrum. The necessary beam shaping behind the source is accomplished by applying magnetic ion lenses like solenoids and quadrupoles and a radiofrequency cavity. Based on the unique beam properties from the laser-driven source, high-current single bunches could be produced and characterized in a recent experiment: At a central energy of 7.8 MeV, up to 5 × 108 protons could be re-focused in time to a FWHM bunch length of τ = (462 ± 40) ps via phase focusing. The bunches show a moderate energy spread between 10% and 15% (ΔE/E0 at FWHM) and are available at 6 m distance to the source und thus separated from the harsh laser-matter interaction environment. These successful experiments represent the basis for developing novel laser-driven ion beamlines and accessing highest peak intensities for ultra-short MeV-range ion bunches.

  11. Avoiding the False Peaks in Correlation Discrimination

    International Nuclear Information System (INIS)

    Awwal, A.S.

    2009-01-01

    Fiducials imprinted on laser beams are used to perform video image based alignment of the 192 laser beams in the National Ignition Facility (NIF) of Lawrence Livermore National Laboratory. In many video images, matched filtering is used to detect the location of these fiducials. Generally, the highest correlation peak is used to determine the position of the fiducials. However, when the signal to-be-detected is very weak compared to the noise, this approach totally breaks down. The highest peaks act as traps for false detection. The active target images used for automatic alignment in the National Ignition Facility are examples of such images. In these images, the fiducials of interest exhibit extremely low intensity and contrast, surrounded by high intensity reflection from metallic objects. Consequently, the highest correlation peaks are caused by these bright objects. In this work, we show how the shape of the correlation is exploited to isolate the valid matches from hundreds of invalid correlation peaks, and therefore identify extremely faint fiducials under very challenging imaging conditions

  12. Tornado hazard model with the variation effects of tornado intensity along the path length

    International Nuclear Information System (INIS)

    Hirakuchi, Hiromaru; Nohara, Daisuke; Sugimoto, Soichiro; Eguchi, Yuzuru; Hattori, Yasuo

    2015-01-01

    Most of Japanese tornados have been reported near the coast line, where all of Japanese nuclear power plants are located. It is necessary for Japanese electric power companies to assess tornado risks on the plants according to a new regulation in 2013. The new regulatory guide exemplifies a tornado hazard model, which cannot consider the variation of tornado intensity along the path length and consequently produces conservative risk estimates. The guide also recommends the long narrow strip area along the coast line with the width of 5-10 km as a region of interest, although the model tends to estimate inadequate wind speeds due to the limit of application. The purpose of this study is to propose a new tornado hazard model which can be apply to the long narrow strip area. The new model can also consider the variation of tornado intensity along the path length and across the path width. (author)

  13. Interfractional Dose Variations in Intensity-Modulated Radiotherapy With Breath-Hold for Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Mitsuhiro [Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto (Japan); Shibuya, Keiko, E-mail: kei@kuhp.kyoto-u.ac.jp [Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto (Japan); Nakamura, Akira [Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto (Japan); Shiinoki, Takehiro [Department of Nuclear Engineering, Kyoto University Graduate School of Engineering, Kyoto (Japan); Matsuo, Yukinori [Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto (Japan); Nakata, Manabu [Clinical Radiology Service Division, Kyoto University Hospital, Kyoto (Japan); Sawada, Akira; Mizowaki, Takashi; Hiraoka, Masahiro [Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto (Japan)

    2012-04-01

    Purpose: To investigate the interfractional dose variations for intensity-modulated radiotherapy (RT) combined with breath-hold (BH) at end-exhalation (EE) for pancreatic cancer. Methods and Materials: A total of 10 consecutive patients with pancreatic cancer were enrolled. Each patient was fixed in the supine position on an individualized vacuum pillow with both arms raised. Computed tomography (CT) scans were performed before RT, and three additional scans were performed during the course of chemoradiotherapy using a conventional RT technique. The CT data were acquired under EE-BH conditions (BH-CT) using a visual feedback technique. The intensity-modulated RT plan, which used five 15-MV coplanar ports, was designed on the initial BH-CT set with a prescription dose of 39 Gy at 2.6 Gy/fraction. After rigid image registration between the initial and subsequent BH-CT scans, the dose distributions were recalculated on the subsequent BH-CT images under the same conditions as in planning. Changes in the dose-volume metrics of the gross tumor volume (GTV), clinical target volume (CTV = GTV + 5 mm), stomach, and duodenum were evaluated. Results: For the GTV and clinical target volume (CTV), the 95th percentile of the interfractional variations in the maximal dose, mean dose, dose covering 95% volume of the region of structure, and percentage of the volume covered by the 90% isodose line were within {+-}3%. Although the volume covered by the 39 Gy isodose line for the stomach and duodenum did not exceed 0.1 mL at planning, the volume covered by the 39 Gy isodose line for these structures was up to 11.4 cm{sup 3} and 1.8 cm{sup 3}, respectively. Conclusions: Despite variations in the gastrointestinal state and abdominal wall position at EE, the GTV and CTV were mostly ensured at the planned dose, with the exception of 1 patient. Compared with the duodenum, large variations in the stomach volume receiving high-dose radiation were observed, which might be beyond the

  14. Variational analysis of self-focusing of intense ultrashort pulses in gases

    International Nuclear Information System (INIS)

    Arevalo, E.; Becker, A.

    2005-01-01

    By using perturbation theory we derive an expression for the electrical field of a Gaussian laser beam propagating in a gas medium. This expression is used as a trial solution in a variational method to get quasianalytical solutions for the width, intensity, and self-focusing distance. The approximation gives a better agreement with results of numerical simulations for a broad range of values of the input power than previous analytical results available in the literature. The results apply in the case of ultrashort pulses too

  15. Seasonal variations of intensity of muons and electrons of decay in points of probe measurements of cosmic radiation in the atmosphere

    International Nuclear Information System (INIS)

    Kurguzova, A.I.; Charakhch'yan, T.N.

    1983-01-01

    Altitude-dependent intensities of muon and electron decay are calculated for the summer and winter seasons in the regions of Murmansk, Moscow, Alma-Ata and Mirnyj (the Antarctica). Values of the calculated temperature coefficients of muonf and electron decay for three levels (50, 500 and 1000 g/cm 2 ) are given. Seasonal variations of the muone and electron intensities are practically the same for all the points at depths X > 300 g/cm 2 (approximately 5% for muons and approximately 1% for electrons); at depths X 2 in Mirnyj the variations are considerably higher than in other points. Seasonal variations of the cosmic ray intensity on the surface of the Earth make up approximately 4%, in the low atmosphere (X=500 g/cm 2 ) they make up approximately 2%. In Mirnyj the seasonal variations of cosmic rays in the stratosphere (X=50 g/cm 2 ) also make up approximately 2%

  16. Spatiotemporal Variation in Surface Urban Heat Island Intensity and Associated Determinants across Major Chinese Cities

    Directory of Open Access Journals (Sweden)

    Juan Wang

    2015-03-01

    Full Text Available Urban heat islands (UHIs created through urbanization can have negative impacts on the lives of people living in cities. They may also vary spatially and temporally over a city. There is, thus, a need for greater understanding of these patterns and their causes. While previous UHI studies focused on only a few cities and/or several explanatory variables, this research provides a comprehensive and comparative characterization of the diurnal and seasonal variation in surface UHI intensities (SUHIIs across 67 major Chinese cities. The factors associated with the SUHII were assessed by considering a variety of related social, economic and natural factors using a regression tree model. Obvious seasonal variation was observed for the daytime SUHII, and the diurnal variation in SUHII varied seasonally across China. Interestingly, the SUHII varied significantly in character between northern and southern China. Southern China experienced more intense daytime SUHIIs, while the opposite was true for nighttime SUHIIs. Vegetation had the greatest effect in the day time in northern China. In southern China, annual electricity consumption and the number of public buses were found to be important. These results have important theoretical significance and may be of use to mitigate UHI effects.

  17. Intra-pulse transition between ion acceleration mechanisms in intense laser-foil interactions

    Energy Technology Data Exchange (ETDEWEB)

    Padda, H.; King, M.; Gray, R. J.; Powell, H. W.; Gonzalez-Izquierdo, B.; Wilson, R.; Dance, R. J.; MacLellan, D. A.; Butler, N. M. H.; Capdessus, R.; McKenna, P., E-mail: paul.mckenna@strath.ac.uk [SUPA Department of Physics, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Stockhausen, L. C. [Centro de Laseres Pulsados (CLPU), Parque Cientifico, Calle del Adaja s/n. 37185 Villamayor, Salamanca (Spain); Carroll, D. C. [Central Laser Facility, STFC Rutherford Appleton Laboratory, Oxfordshire OX11 0QX (United Kingdom); Yuan, X. H. [Key Laboratory for Laser Plasmas (Ministry of Education) and Department of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China); Collaborative Innovation Center of IFSA (CICIFSA), Shanghai Jiao Tong University, Shanghai 200240 (China); Borghesi, M. [Centre for Plasma Physics, Queens University Belfast, Belfast BT7 1NN (United Kingdom); Neely, D. [SUPA Department of Physics, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Central Laser Facility, STFC Rutherford Appleton Laboratory, Oxfordshire OX11 0QX (United Kingdom)

    2016-06-15

    Multiple ion acceleration mechanisms can occur when an ultrathin foil is irradiated with an intense laser pulse, with the dominant mechanism changing over the course of the interaction. Measurement of the spatial-intensity distribution of the beam of energetic protons is used to investigate the transition from radiation pressure acceleration to transparency-driven processes. It is shown numerically that radiation pressure drives an increased expansion of the target ions within the spatial extent of the laser focal spot, which induces a radial deflection of relatively low energy sheath-accelerated protons to form an annular distribution. Through variation of the target foil thickness, the opening angle of the ring is shown to be correlated to the point in time transparency occurs during the interaction and is maximized when it occurs at the peak of the laser intensity profile. Corresponding experimental measurements of the ring size variation with target thickness exhibit the same trends and provide insight into the intra-pulse laser-plasma evolution.

  18. Periodic transmission peak splitting in one dimensional disordered photonic structures

    Science.gov (United States)

    Kriegel, Ilka; Scotognella, Francesco

    2016-08-01

    In the present paper we present ways to modulate the periodic transmission peaks arising in disordered one dimensional photonic structures with hundreds of layers. Disordered structures in which the optical length nd (n is the refractive index and d the layer thickness) is the same for each layer show regular peaks in their transmission spectra. A proper variation of the optical length of the layers leads to a splitting of the transmission peaks. Notably, the variation of the occurrence of high and low refractive index layers, gives a tool to tune also the width of the peaks. These results are of highest interest for optical application, such as light filtering, where the manifold of parameters allows a precise design of the spectral transmission ranges.

  19. Electromagnetic design of a β=0.4 superconducting spoke resonator for a high intensity proton linac

    International Nuclear Information System (INIS)

    Pathak, Abhishek; Krishnagopal, Srinivas

    2015-01-01

    Here we present electromagnetic design simulations of a superconducting single-spoke resonator with a geometrical beta of 0.4 and operating at 325 MHz for a high intensity proton linac (HIPL). The spoke equatorial and base parameters were optimized to minimize the peak electric and peak magnetic fields and maximize the shunt impedance, while keeping the same resonant frequency. Variation of the surface magnetic fields was investigated as a function of the spoke base shape, and it was found that an elliptical profile is preferred over a circular or racecourse profile with E peak /E acc =4.71, E peak /E acc =4.33 (mT/(MV/m)) and R/Q=272 Ω. (author)

  20. Characteristic of 120 degree C thermoluminescence peak of iceland spar

    International Nuclear Information System (INIS)

    Lu Xinwei; Han Jia

    2006-01-01

    The basic characteristic of 120 degree C thermoluminescence peak of iceland spar was studied. The experimental result indicates the longevity of 120 degree C thermoluminescence peak of iceland spar is about 2 h under 30 degree C. The thermoluminescence peak moves to the high temperature when the heating speed increasing. The intensity of 120 degree C thermoluminescence peak of iceland spar is directly proportional to radiation dose under 15 Gy. (authors)

  1. The influence of dose on the kinetic parameters and dosimetric features of the main thermoluminescence glow peak in α-Al{sub 2}O{sub 3}:C,Mg

    Energy Technology Data Exchange (ETDEWEB)

    Kalita, J.M.; Chithambo, M.L., E-mail: m.chithambo@ru.ac.za

    2017-03-01

    Highlights: • Influence of dose on thermoluminescence features of α-Al{sub 2}O{sub 3}:C,Mg have been studied. • Kinetic parameters of the main peak are independent of dose (0.1–100 Gy). • Dose response of the main peak: 0.1–30 Gy, superlinear; 30–100 Gy, sublinear. • Fading of the main peak: ∼22% within 2400 s. • Reproducibility: coefficient of variation in the results of 10 re-cycles: >0.071%. - Abstract: The influence of dose (0.1–100 Gy) on the kinetic parameters and the dosimetric features of the main glow peak of α-Al{sub 2}O{sub 3}:C,Mg have been investigated. Thermoluminescence (TL) measured at 1 °C/s shows a very high intensity glow peak at 161 °C and six secondary peaks at 42, 72, 193, 279, 330, 370 °C respectively. Analysis shows that the main peak follows first order kinetics irrespective of the irradiation dose. The activation energy is found to be consistent at 1.37 eV and the frequency factor is of the order of 10{sup 14} s{sup −1} for any dose between 0.1 and 100 Gy. Further, the analysis for thermal quenching of the main peak of 0.1 Gy irradiated sample shows that the activation energy for thermal quenching is (0.94 ± 0.04) eV. Regarding the dosimetric features of α-Al{sub 2}O{sub 3}:C,Mg, the dose response of the main peak is superlinear within 0.1 to 30 Gy of beta dose and then it becomes sublinear up to 100 Gy. Fading analysis shows that the intensity of the main peak drops to ∼22% of its initial value within 2400 s after irradiation and thereafter to ∼14% within 64,800 s. Analysis of the reproducibility shows that the coefficient of variation in the results for 10 identical TL measurements show that reproducibility improves with increase in dose.

  2. High-resolution records of non-dipole variations in the intensity of the Earth's magnetic field

    NARCIS (Netherlands)

    de Groot, L.V.

    2013-01-01

    Our understanding of the short-term behavior of the Earth’s magnetic field is currently mainly hampered by a lack of high-resolution records of geomagnetic intensity variations that are well distributed over the globe and cover the same timespan. Over the past decades many efforts have been made to

  3. Predicting the effects of organ motion on the dose delivered by dynamic intensity modulation

    International Nuclear Information System (INIS)

    Yu, C.X.; Jaffray, David; Martinez, A.A.; Wong, J.W.

    1997-01-01

    of several breathing cycles. To simplify the analysis, the three-dimensional target was projected to one depth level and the movements of the target along beam direction were assumed to have negligible effects. Results: The dose variations in the target due to the interplay of the target motion and the movement of the beam aperture can be large, over 100% (peak-to-peak) for a clinically realistic range of the speed of collimator travel and size of field segments. Predictions using the numerical model agreed with results measured with a moving phantom. The magnitude of the dose variations in the target showed strong dependence on the collimator speed relative to the speed of the target motion, and the size of field segments relative to the amplitude of target motion. The dose variation was small when the speed of field boundary variation is very low. The dose variation decreased with the size of the field segments. When the treatment was delivered in multiple fractions, the desired beam intensities were smoothed, defeating the purpose of intensity modulation. Conclusion: A simple model was developed to analyze the dosimetric effects of target movement during delivery of dynamic intensity modulation. The dose distributions in a moving target can be predicted before an intensity-modulated treatment is delivered. In regions where the target moves during irradiation, the detrimental dosimetric effects could be significant and cannot be neglected. In such cases, methods of fixing the target position, such as gating or breathing control, are required for dynamic intensity modulation to be delivered

  4. DISCOVERY OF TIME VARIATION OF THE INTENSITY OF MOLECULAR LINES IN IRC+10216 IN THE SUBMILLIMETER AND FAR-INFRARED DOMAINS

    Energy Technology Data Exchange (ETDEWEB)

    Cernicharo, J.; Quintana-Lacaci, G.; Agúndez, M.; Velilla-Prieto, L. [Group of Molecular Astrophysics, ICMM, CSIC, C/Sor Juana Inés de La Cruz N3, E-28049 Madrid (Spain); Teyssier, D.; García-Lario, P. [ESA, ESAC, P.O. Box 78, Villanueva de la Cañada, E-28691 Madrid (Spain); Daniel, F. [Univ. Grenoble Alpes, IPAG, F-38000 Grenoble (France); Decin, L. [Instituut voor Sterrenkunde, Katholieke Universiteit Leuven, Celestijnenlaan 200D, B-3001 Leuven (Belgium); Guélin, M. [Institut de Radioastronomie Millimétrique, 300 rue de la Piscine, F-38406 St-Martin d' Hères (France); Encrenaz, P. [LERMA, Observatoire de Paris, 61 Av. de l' Observatoire, F-75014 Paris (France); De Beck, E. [Department of Earth and Space Sciences, Chalmers University of Technology, Onsala Space Observatory, SE 439 92 Onsala (Sweden); Barlow, M. J. [Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT (United Kingdom); Groenewegen, M. A. T. [Koninklijke Sterrenwacht van België, Ringlaan 3, B-1180 Brussels (Belgium); Neufeld, D. [Department of Physics and Astronomy, Johns Hopkins University, 3400 North Charles Street, Baltimore, MD 21218 (United States); Pearson, J. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States)

    2014-11-20

    We report on the discovery of strong intensity variations in the high rotational lines of abundant molecular species toward the archetypical circumstellar envelope of IRC+10216. The observations have been carried out with the Heterodyne Instrument for the Far-Infrared (HIFI) instrument on board Herschel and with the IRAM30 m telescope. They cover several observing periods spreading over three years. The line intensity variations for molecules produced in the external layers of the envelope most likely result from time variations in the infrared pumping rates. We analyze the main implications this discovery has on the interpretation of molecular line emission in the envelopes of Mira-type stars. Radiative transfer calculations must take into account both the time variability of infrared pumping and the possible variation of the dust and gas temperatures with stellar phase in order to reproduce the observation of molecular lines at different epochs. The effect of gas temperature variations with stellar phase could be particularly important for lines produced in the innermost regions of the envelope. Each layer of the circumstellar envelope sees the stellar light radiation with a different lag time (phase). Our results show that this effect must be included in the models. The submillimeter and far infrared lines of asymptotic giant branch stars can no longer be considered as safe intensity calibrators.

  5. Time Variations of the Radial Velocity of H2O Masers in the Semi-Regular Variable R Crt

    Science.gov (United States)

    Sudou, Hiroshi; Shiga, Motoki; Omodaka, Toshihiro; Nakai, Chihiro; Ueda, Kazuki; Takaba, Hiroshi

    2017-12-01

    H2O maser emission {at 22 GHz} in the circumstellar envelope is one of the good tracers of detailed physics and inematics in the mass loss process of asymptotic giant branch stars. Long-term monitoring of an H2O maser spectrum with high time resolution enables us to clarify acceleration processes of the expanding shell in the stellar atmosphere. We monitored the H2O maser emission of the semi-regular variable R Crt with the Kagoshima 6-m telescope, and obtained a large data set of over 180 maser spectra over a period of 1.3 years with an observational span of a few days. Using an automatic peak detection method based on least-squares fitting, we exhaustively detected peaks as significant velocity components with the radial velocity on a 0.1 km s^{-1} scale. This analysis result shows that the radial velocity of red-shifted and blue-shifted components exhibits a change between acceleration and deceleration on the time scale of a few hundred days. These velocity variations are likely to correlate with intensity variations, in particular during flaring state of H2O masers. It seems reasonable to consider that the velocity variation of the maser source is caused by shock propagation in the envelope due to stellar pulsation.However, it is difficult to explain the relationship between the velocity variation and the intensity variation only from shock propagation effects. We found that a time delay of the integrated maser intensity with respect to the optical light curve is about 150 days.

  6. Four Weeks of Off-Season Training Improves Peak Oxygen Consumption in Female Field Hockey Players

    OpenAIRE

    Lindsey T. Funch; Erik Lind; Larissa True; Deborah Van Langen; John T. Foley; James F. Hokanson

    2017-01-01

    The purpose of the study was to examine the changes in peak oxygen consumption ( V ˙O2peak) and running economy (RE) following four-weeks of high intensity training and concurrent strength and conditioning during the off-season in collegiate female field hockey players. Fourteen female student-athletes (age 19.29 ± 0.91 years) were divided into two training groups, matched from baseline V ˙O2peak: High Intensity Training (HITrun; n = 8) and High Intensity Interval Training (HIIT; ...

  7. Worldwide variation in atmospheric noise intensities with sunspot number: an in-depth look at the 20 to 24 hour seasonal time block

    International Nuclear Information System (INIS)

    Joglekar, P.J.; Sathiamurthy, T.S.

    1975-01-01

    Comparisons of the variation of atmospheric radio noise intensities for 20 to 24 hr to sunspot numbers have been completed. Statistical dependence between the noise intensities and sunspot numbers was found for different seasons at a number of frequencies for many locations in the global network of ARN-2 noise recorders. The noise intensities generally tended to decrease with sunspot number in the range from 50 kHz to 5 MHz, which is presumed to be due to increases in residual ionospheric absorption during nighttime. At frequencies greater than 5 MHz, noise intensities increased with sunspot number in many cases, which would be expected from our present knowledge of ionospheric behavior in the HF range. By convention, CCIR treats year-to-year variation in the noise intensities as random and includes them in the prediction uncertainty sigma /sub Fam/ (for which one value is given at a frequency for a seasonal time block for all locations) in system performance evaluation. An error analysis on a global basis shows that a large portion of the year-to-year variability is due to sunspot variation. This suggests the possibility of improved noise estimates. (auth)

  8. variations of peak expiratory flow rate with anthropometric

    African Journals Online (AJOL)

    admin

    Decreased bronchomotor tone would lead to a fall in airway resistance, and hence increased flow rate of air along it. Tests of. PEFR reflect changes in airway calibers. (Hughes and Empey, 1981). There have been reports on the variations of various ventilatory parameters with anthropometric determinants in. Nigerians.

  9. The road to gold: training and peaking characteristics in the year prior to a gold medal endurance performance.

    Directory of Open Access Journals (Sweden)

    Espen Tønnessen

    Full Text Available To describe training variations across the annual cycle in Olympic and World Champion endurance athletes, and determine whether these athletes used tapering strategies in line with recommendations in the literature.Eleven elite XC skiers and biathletes (4 male; 28±1 yr, 85±5 mL x min(-1 x kg(-1 VO2max, 7 female, 25±4 yr, 73±3 mL x min(-1 x kg(-1 VO2max reported one year of day-to-day training leading up to the most successful competition of their career. Training data were divided into periodization and peaking phases and distributed into training forms, intensity zones and endurance activity forms.Athletes trained ∼800 h/500 sessions x year(-1, including ∼500 h x year(-1 of sport-specific training. Ninety-four percent of all training was executed as aerobic endurance training. Of this, ∼90% was low intensity training (LIT, below the first lactate threshold and 10% high intensity training (HIT, above the first lactate threshold by time. Categorically, 23% of training sessions were characterized as HIT with primary portions executed at or above the first lactate turn point. Training volume and specificity distribution conformed to a traditional periodization model, but absolute volume of HIT remained stable across phases. However, HIT training patterns tended to become more polarized in the competition phase. Training volume, frequency and intensity remained unchanged from pre-peaking to peaking period, but there was a 32±15% (P<.01 volume reduction from the preparation period to peaking phase.The annual training data for these Olympic and World champion XC skiers and biathletes conforms to previously reported training patterns of elite endurance athletes. During the competition phase, training became more sport-specific, with 92% performed as XC skiing. However, they did not follow suggested tapering practice derived from short-term experimental studies. Only three out of 11 athletes took a rest day during the final 5 days prior to

  10. Statistical intensity variation analysis for rapid volumetric imaging of capillary network flux.

    Science.gov (United States)

    Lee, Jonghwan; Jiang, James Y; Wu, Weicheng; Lesage, Frederic; Boas, David A

    2014-04-01

    We present a novel optical coherence tomography (OCT)-based technique for rapid volumetric imaging of red blood cell (RBC) flux in capillary networks. Previously we reported that OCT can capture individual RBC passage within a capillary, where the OCT intensity signal at a voxel fluctuates when an RBC passes the voxel. Based on this finding, we defined a metric of statistical intensity variation (SIV) and validated that the mean SIV is proportional to the RBC flux [RBC/s] through simulations and measurements. From rapidly scanned volume data, we used Hessian matrix analysis to vectorize a segment path of each capillary and estimate its flux from the mean of the SIVs gathered along the path. Repeating this process led to a 3D flux map of the capillary network. The present technique enabled us to trace the RBC flux changes over hundreds of capillaries with a temporal resolution of ~1 s during functional activation.

  11. Seasonal and Spatial Variation of Surface Urban Heat Island Intensity in a Small Urban Agglomerate in Brazil

    Directory of Open Access Journals (Sweden)

    Elis Dener Lima Alves

    2016-12-01

    Full Text Available In recent years, SUHIs (surface urban heat islands have been greatly emphasized in urban climate studies, since it is one of the climate phenomena most influenced by human action. In this study, temporal and spatial variations of SUHIs in the cities of Ceres and Rialma (Brazil were investigated; satellite Landsat 8 TIRS/OLI images from 2013 to 2016 were used for this purpose. The results showed that in all seasons, two relationships were observed, one positive and one negative. An N D V I (Normalized Difference Vegetation Index of 0.2 is the divider of this relationship: up to this value, the relationship is positive, that is, the higher the N D V I value, the higher the surface temperature, while the relationship is negative at an N D V I greater than 0.2. There was high seasonal variation in the SUHIs, with the highest intensities recorded in the spring and summer (±12 °C, and the lowest in the winter. These temporal variations were attributed to the annual cycle of precipitation, which directly involves the robustness of the Cerrado vegetation. SUHIs occupied, on average, an area three times larger than the area of SUCIs (surface urban cool islands. The highest values of SUCIs were observed in water bodies and in valley bottoms. Overall, SUHIs showed high intensities; however, a more intense core area, such as in large cities, was not observed.

  12. Functional High-Intensity Circuit Training Improves Body Composition, Peak Oxygen Uptake, Strength, and Alters Certain Dimensions of Quality of Life in Overweight Women.

    Science.gov (United States)

    Sperlich, Billy; Wallmann-Sperlich, Birgit; Zinner, Christoph; Von Stauffenberg, Valerie; Losert, Helena; Holmberg, Hans-Christer

    2017-01-01

    The effects of circuit-like functional high-intensity training (Circuit HIIT ) alone or in combination with high-volume low-intensity exercise (Circuit combined ) on selected cardio-respiratory and metabolic parameters, body composition, functional strength and the quality of life of overweight women were compared. In this single-center, two-armed randomized, controlled study, overweight women performed 9-weeks (3 sessions·wk -1 ) of either Circuit HIIT ( n = 11), or Circuit combined ( n = 8). Peak oxygen uptake and perception of physical pain were increased to a greater extent ( p body mass, body-mass-index, waist-to-hip ratio, fat mass, and enhanced fat-free mass; decreased ratings of perceived exertion during submaximal treadmill running; improved the numbers of push-ups, burpees, one-legged squats, and 30-s skipping performed, as well as the height of counter-movement jumps; and improved physical and social functioning, role of physical limitations, vitality, role of emotional limitations, and mental health to a similar extent (all p training can be employed to improve body composition, selected variables of functional strength, and certain dimensions of quality of life in overweight women. However, Circuit HIIT improves peak oxygen uptake to a greater extent, but with more perception of pain, whereas Circuit combined results in better perception of general health.

  13. Figure-of-merit (FOM), an improved criterion over the normalized chi-squared test for assessing goodness-of-fit of gamma-ray spectral peaks

    International Nuclear Information System (INIS)

    Garo Balian, H.; Eddy, N.W.

    1977-01-01

    A careful experimenter knows that in order to choose the best curve fits of peaks from a gamma ray spectrum for such purposes as energy or intensity calibration, half-life determination, etc., the application of the normalized chi-squared test, [chisub(N)] 2 =chi 2 /(n-m), is insufficient. One must normally verify the goodness-of-fit with plots, detailed scans of residuals, etc. Because of different techniques of application, variations in backgrounds, in peak sizes and shapes, etc., quotation of the [chisub(N)] 2 value associated with an individual peak fit conveys very little information unless accompanied by considerable ancillary data. (This is not to say that the traditional chi 2 formula should not be used as the source of the normal equations in the least squares fitting procedure. But after the fitting, it is unreliable as a criterion for comparison with other fits.) The authors present a formula designated figure-of-merit (FOM) which greatly improves on the uncertainty and fluctuations of the [chisub(N)] 2 formula. An FOM value of less than 2.5% indicates a good fit (in the authors' judgement) irrespective of background conditions and variations in peak sizes and shapes. Furthermore, the authors feel the FOM formula is less subject to fluctuations resulting from different techniques of application. (Auth.)

  14. Gamma-ray peak shapes from cadmium zinc telluride detectors

    Energy Technology Data Exchange (ETDEWEB)

    Namboodiri, M.N.; Lavietes, A.D.; McQuaid, J.H.

    1996-09-01

    We report the results of a study of the peak shapes in the gamma spectra measured using several 5 x 5 x 5 mm{sup 3} cadmium zinc telluride (CZT) detectors. A simple parameterization involving a Gaussian and an exponential low energy tail describes the peak shapes sell. We present the variation of the parameters with gamma energy. This type of information is very useful in the analysis of complex gamma spectra consisting of many peaks.

  15. Multiscale peak detection in wavelet space.

    Science.gov (United States)

    Zhang, Zhi-Min; Tong, Xia; Peng, Ying; Ma, Pan; Zhang, Ming-Jin; Lu, Hong-Mei; Chen, Xiao-Qing; Liang, Yi-Zeng

    2015-12-07

    Accurate peak detection is essential for analyzing high-throughput datasets generated by analytical instruments. Derivatives with noise reduction and matched filtration are frequently used, but they are sensitive to baseline variations, random noise and deviations in the peak shape. A continuous wavelet transform (CWT)-based method is more practical and popular in this situation, which can increase the accuracy and reliability by identifying peaks across scales in wavelet space and implicitly removing noise as well as the baseline. However, its computational load is relatively high and the estimated features of peaks may not be accurate in the case of peaks that are overlapping, dense or weak. In this study, we present multi-scale peak detection (MSPD) by taking full advantage of additional information in wavelet space including ridges, valleys, and zero-crossings. It can achieve a high accuracy by thresholding each detected peak with the maximum of its ridge. It has been comprehensively evaluated with MALDI-TOF spectra in proteomics, the CAMDA 2006 SELDI dataset as well as the Romanian database of Raman spectra, which is particularly suitable for detecting peaks in high-throughput analytical signals. Receiver operating characteristic (ROC) curves show that MSPD can detect more true peaks while keeping the false discovery rate lower than MassSpecWavelet and MALDIquant methods. Superior results in Raman spectra suggest that MSPD seems to be a more universal method for peak detection. MSPD has been designed and implemented efficiently in Python and Cython. It is available as an open source package at .

  16. Solar center-limb variation of the Ca II K line and the Wilson-Bappu effect

    International Nuclear Information System (INIS)

    Engvold, O.; Marstad, N.C.

    1983-01-01

    New observations of the quiet Sun Ca II K line center-to-limb (C-L) have been made. The separation of the K 2 intensity peaks, the K 1 intensity minima and the intermediate width W 0 (the Wilson-Bappu width) are presented. It is shown that the C-L variation of all three parameters can be accounted for as a dependence on chromospheric column mass. The corresponding Ca II K line with parameters of 41 late type stars are also shown to vary in accordance with the inferred chromospheric column mass of the stars. The solar C-L and the stellar variation of the widths ΔK 1 and W 0 are found to have nearly indentical factors of proportionality with respect to log (column mass)

  17. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2017-01-01

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  18. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas

    2017-09-18

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  19. Simultaneous collection method of on-peak window image and off-peak window image in Tl-201 imaging

    International Nuclear Information System (INIS)

    Murakami, Tomonori; Noguchi, Yasushi; Kojima, Akihiro; Takagi, Akihiro; Matsumoto, Masanori

    2007-01-01

    Tl-201 imaging detects the photopeak (71 keV, in on-peak window) of characteristic X-rays of Hg-201 formed from Tl-201 decay. The peak is derived from 4 rays of different energy and emission intensity and does not follow in Gaussian distribution. In the present study, authors made an idea for the method in the title to attain the more effective single imaging, which was examined for its accuracy and reliability with phantoms and applied clinically to Tl-201 scintigraphy in a patient. The authors applied the triple energy window method for data acquisition: the energy window setting was made on Hg-201 X-rays photopeak in three of the lower (3%, L), main (72 keV, M) and upper (14%, U) windows with the gamma camera with 2-gated detector (Toshiba E. CAM/ICON). L, M and U images obtained simultaneously were then constructed to images of on-peak (L+M, Mock on-peak) and off-peak (M+U) window settings for evaluation. Phantoms for line source with Tl-201-containing swab and for multi-defect with acrylic plate containing Tl-201 solution were imaged in water. The female patient with thyroid cancer was subjected to preoperative scintigraphy under the defined conditions. Mock on-, off-peak images were found to be equivalent to the true (ordinary, clinical) on-, off-peak ones, and the present method was thought usable for evaluation of usefulness of off-peak window data. (R.T.)

  20. Diffraction peaks in x-ray spectroscopy: Friend or foe?

    International Nuclear Information System (INIS)

    Tissot, R.G.; Goehner, R.P.

    1992-01-01

    Diffraction peaks can occur as unidentifiable peaks in the energy spectrum of an x-ray spectrometric analysis. Recently, there has been increased interest in oriented polycrystalline films and epitaxial films on single crystal substrates for electronic applications. Since these materials diffract x-rays more efficiently than randomly oriented polycrystalline materials, diffraction peaks are being observed more frequently in x-ray fluorescent spectra. In addition, micro x-ray spectrometric analysis utilizes a small, intense, collimated x-ray beam that can yield well defined diffraction peaks. In some cases these diffraction peaks can occur at the same position as elemental peaks. These diffraction peaks, although a possible problem in qualitative and quantitative elemental analysis, can give very useful information about the crystallographic structure and orientation of the material being analyzed. The observed diffraction peaks are dependent on the geometry of the x-ray spectrometer, the degree of collimation and the distribution of wavelengths (energies) originating from the x-ray tube and striking the sample

  1. Experimental investigation of the multiple scatter peak of gamma rays in portland cement in the energy range 279-1332 keV

    International Nuclear Information System (INIS)

    Singh, Tejbir; Singh, Parjit S

    2011-01-01

    The pulse height spectra for different thicknesses of portland cement in the reflected geometry has been recorded with the help of a NaI(Tl) scintillator detector and 2 K MCA card using different gamma-ray sources such as Hg 203 (279 keV), Cs 137 (662 keV) and Co 60 (1173 and 1332 keV). It has been observed that the multiple scatter peak for portland cement appears at 110 (±7) keV in all the spectra irrespective of different incident photon energies in the range 279-1332 keV from different gamma-ray sources. Further, the variation in the intensity of the multiple scatter peak with the thickness of portland cement in the backward semi-cylinders has been investigated.

  2. An Empirical Study on Raman Peak Fitting and Its Application to Raman Quantitative Research.

    Science.gov (United States)

    Yuan, Xueyin; Mayanovic, Robert A

    2017-10-01

    Fitting experimentally measured Raman bands with theoretical model profiles is the basic operation for numerical determination of Raman peak parameters. In order to investigate the effects of peak modeling using various algorithms on peak fitting results, the representative Raman bands of mineral crystals, glass, fluids as well as the emission lines from a fluorescent lamp, some of which were measured under ambient light whereas others under elevated pressure and temperature conditions, were fitted using Gaussian, Lorentzian, Gaussian-Lorentzian, Voigtian, Pearson type IV, and beta profiles. From the fitting results of the Raman bands investigated in this study, the fitted peak position, intensity, area and full width at half-maximum (FWHM) values of the measured Raman bands can vary significantly depending upon which peak profile function is used in the fitting, and the most appropriate fitting profile should be selected depending upon the nature of the Raman bands. Specifically, the symmetric Raman bands of mineral crystals and non-aqueous fluids are best fit using Gaussian-Lorentzian or Voigtian profiles, whereas the asymmetric Raman bands are best fit using Pearson type IV profiles. The asymmetric O-H stretching vibrations of H 2 O and the Raman bands of soda-lime glass are best fit using several Gaussian profiles, whereas the emission lines from a florescent light are best fit using beta profiles. Multiple peaks that are not clearly separated can be fit simultaneously, provided the residuals in the fitting of one peak will not affect the fitting of the remaining peaks to a significant degree. Once the resolution of the Raman spectrometer has been properly accounted for, our findings show that the precision in peak position and intensity can be improved significantly by fitting the measured Raman peaks with appropriate profiles. Nevertheless, significant errors in peak position and intensity were still observed in the results from fitting of weak and wide Raman

  3. Cosmic ray intensity in the past

    International Nuclear Information System (INIS)

    Dergachev, V.A.

    1977-01-01

    Variations of cosmic rays have been investigated according to the data on the content of radiocarbon in the Earth atmosphere, on the solar activity and on the geomagnetic field. The results of spectral analysis of the data on radiocarbon (1688-1951 time interval) and the data on the numbers of sunspots have been compared. As a result of spectral analysis it has been established that the two main peaks coincide in periods (approximately 11 and approximately 80 years) and differ in amplitudes. The 11-year periods are the main periods for the solar activity, and the 80-year periods for the radiocarbon concentration. To elucidate the role of the geomagnetic field in the cosmic ray variations considered are extermal changes in the magnetic field and variations in the radiocarbon content for four time intervals: 0-500 years, 750-2200 years, 2200-4500 years and 4500-6800 years form the present. The following cycles have been revealed in the time spectra of radiocarbon; approximately 600, approximately 360, approximately 80, approximately 36 years, their relative amplitude decreasing with the period. The absence of short-range solar syscle is typical for the geomagnetic field intensity

  4. RECORD-SETTING COSMIC-RAY INTENSITIES IN 2009 AND 2010

    International Nuclear Information System (INIS)

    Mewaldt, R. A.; Davis, A. J.; Leske, R. A.; Stone, E. C.; Cummings, A. C.; Labrador, A. W.; Lave, K. A.; Binns, W. R.; Israel, M. H.; Wiedenbeck, M. E.; Christian, E. R.; De Nolfo, G. A.; Von Rosenvinge, T. T.

    2010-01-01

    We report measurements of record-setting intensities of cosmic-ray nuclei from C to Fe, made with the Cosmic Ray Isotope Spectrometer carried on the Advanced Composition Explorer in orbit about the inner Sun-Earth Lagrangian point. In the energy interval from ∼70 to ∼450 MeV nucleon -1 , near the peak in the near-Earth cosmic-ray spectrum, the measured intensities of major species from C to Fe were each 20%-26% greater in late 2009 than in the 1997-1998 minimum and previous solar minima of the space age (1957-1997). The elevated intensities reported here and also at neutron monitor energies were undoubtedly due to several unusual aspects of the solar cycle 23/24 minimum, including record-low interplanetary magnetic field (IMF) intensities, an extended period of reduced IMF turbulence, reduced solar-wind dynamic pressure, and extremely low solar activity during an extended solar minimum. The estimated parallel diffusion coefficient for cosmic-ray transport based on measured solar-wind properties was 44% greater in 2009 than in the 1997-1998 solar-minimum period. In addition, the weaker IMF should result in higher cosmic-ray drift velocities. Cosmic-ray intensity variations at 1 AU are found to lag IMF variations by 2-3 solar rotations, indicating that significant solar modulation occurs inside ∼20 AU, consistent with earlier galactic cosmic-ray radial-gradient measurements. In 2010, the intensities suddenly decreased to 1997 levels following increases in solar activity and in the inclination of the heliospheric current sheet. We describe the conditions that gave cosmic rays greater access to the inner solar system and discuss some of their implications.

  5. Neutron-induced peaks in Ge detectors from evaporation neutrons

    International Nuclear Information System (INIS)

    Gete, E.; Measday, D.F.; Moftah, B.A.; Saliba, M.A.; Stocki, T.J.

    1997-01-01

    We have studied the peak shapes at 596 and 691 keV resulting from fast neutron interactions inside germanium detectors. We have used neutrons from a 252 Cf source, as well as from the 28 Si(μ - , nν), and 209 Bi(π - , xn) reactions to compare the peaks and to check for a dependence of peak shape on the incoming neutron energy. In our investigation, no difference between these three measurements has been observed. In a comparison of these peak shapes with other studies, we found similar results to ours except for those measurements using monoenergetic neutrons in which a significant variation with neutron energy has been observed. (orig.)

  6. High-intensity interval training improves VO2peak, maximal lactate accumulation, time trial and competition performance in 9?11-year-old swimmers

    OpenAIRE

    Sperlich, Billy; Zinner, Christoph; Heilemann, Ilka; Kjendlie, Per-Ludvik; Holmberg, Hans-Christer; Mester, Joachim

    2010-01-01

    Training volume in swimming is usually very high when compared to the relatively short competition time. High-intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. The main purpose of the present study was to examine the effects of a 5-week HIIT versus high-volume training (HVT) in 9?11-year-old swimmers on competition performance, 100 and 2,000?m time (T 100?m and T 2,000?m), VO2peak and rate of maximal lactate accumulation (La...

  7. Statistical analysis of the low-temperature dislocation peak of internal friction (Bordoni peak) in nanostructured copper

    International Nuclear Information System (INIS)

    Vatazhuk, E.N.; Natsik, V.D.

    2011-01-01

    The temperature-frequency dependence of internal friction in the nanostructured samples of Cu and fibred composite C-32 vol.%Nb with the sizes of structure fragments approx 200 nm is analyzed. Experiments are used as initial information for such analysis. The characteristic for the heavily deformed copper Bordoni peak, located nearby a temperature 90 K, was recorded on temperature dependence of vibration decrement (frequencies 73-350 kHz) in previous experiments. The peak is due to the resonance interaction of sound with the system of thermal activated relaxators, and its width considerably greater in comparison with the width of standard internal friction peak with the single relaxation time. Statistical analysis of the peak is made in terms of assumption that the reason of broadening is random activation energy dispersion of relaxators as a result of intense distortion of copper crystal structure. Good agreement of experimental data and Seeger theory considers thermal activated paired kinks at linear segments of dislocation lines, placed in potential Peierls relief valley, as relaxators of Bordoni peak, was established. It is shown that the registered peak height in experiment correspond to presence at the average one dislocation segment in the interior of crystalline grain with size of 200 nm. Empirical estimates for the critical Peierls stress σp ∼ 2x10 7 Pa and integrated density of the interior grain dislocations ρ d ∼ 10 13 m -2 are made. Nb fibers in the composite Cu-Nb facilitate to formation of nanostructured copper, but do not influence evidently on the Bordoni peak.

  8. On the role of magnetic field intensity for better micro-structural characterization during Barkhausen Noise analysis

    Science.gov (United States)

    Yusufzai, Mohd Zaheer Khan; Vashista, M.

    2018-04-01

    Barkhausen Noise analysis is a popular and preferred technique for micro-structural characterization. The root mean square value and peak value of Barkhausen Noise burst are important parameters to assess the micro-hardness and residual stress. Barkhausen Noise burst can be enveloped using a curve known as Barkhausen Noise profile. Peak position of profile changes with change in micro-structure. In the present work, raw signal of Barkhausen Noise burst was obtained from Ni based sample at various magnetic field intensity to observe the effect of variation in field intensity on Barkhausen Noise burst. Raw signal was opened using MATLAB to further process for microstructure analysis. Barkhausen Noise analysis parameters such as magnetizing frequency, number of burst, high pass and low pass filter frequency were kept constant and magnetizing field was varied in wide range between 200 Oe to 1200 Oe. The processed profiles of Barkhausen Noise burst obtained at various magnetizing field intensity clearly reveals requirement of optimum magnetic field strength for better characterization of micro-structure.

  9. Field-aligned currents observed by CHAMP during the intense 2003 geomagnetic storm events

    Directory of Open Access Journals (Sweden)

    H. Wang

    2006-03-01

    Full Text Available This study concentrates on the characteristics of field-aligned currents (FACs in both hemispheres during the extreme storms in October and November 2003. High-resolution CHAMP magnetic data reflect the dynamics of FACs during these geomagnetic storms, which are different from normal periods. The peak intensity and most equatorward location of FACs in response to the storm phases are examined separately for both hemispheres, as well as for the dayside and nightside. The corresponding large-scale FAC peak densities are, on average, enhanced by about a factor of 5 compared to the quiet-time FACs' strengths. And the FAC densities on the dayside are, on average, 2.5 times larger in the Southern (summer than in the Northern (winter Hemisphere, while the observed intensities on the nightside are comparable between the two hemispheres. Solar wind dynamic pressure is correlated with the FACs strength on the dayside. However, the latitudinal variations of the FACs are compared with the variations in Dst and the interplanetary magnetic field component Bz, in order to determine how these parameters control the large-scale FACs' configuration in the polar region. We have determined that (1 the equatorward shift of FACs on the dayside is directly controlled by the southward IMF Bz and there is a saturation of the latitudinal displacement for large value of negative Bz. In the winter hemisphere this saturation occurs at higher latitudes than in the summer hemisphere. (2 The equatorward expansion of the nightside FACs is delayed with respect to the solar wind input. The poleward recovery of FACs on the nightside is slower than on the dayside. The latitudinal variations on the nightside are better described by the variations of the Dst index. (3 The latitudinal width of the FAC region on the nightside spreads over a wide range of about 25° in latitude.

  10. The day-night variation of cosmic rays intensity at sea level under the influence of meteorological fronts and troughs

    International Nuclear Information System (INIS)

    Mok, H.M.; Cheng, K.M.

    2000-01-01

    The day-night variation of cosmic rays (CR) intensity at sea level has been observed by a simple G-M counter telescope. We perform two 5 hours counting during the day and the night and find that the pattern of variation is closely related to the atmospheric disturbance. The normal pattern shows that the day counts is a few percents lower than that of the night counts. This can be simply explained by the temperature effect. But when our observation station is being affected by a meteorological front or trough, a reversal occurs. At times the reversal pattern occurs even up to a few days ahead the formation of the troughs at a few hundred kilometers away. Such a reversal may lasts for a few days until the influence of the front or trough has significantly weakened. This effect also overrides the barometric effect, except when there is a sharp change of air pressure, such as during the approach of a tropical cyclone. Our further investigation shows that the pattern of variation may be negatively correlated to the altitude of the 0degC level in the atmosphere. A 150 m upward shift of the 0degC level reduces the CR intensity by about 3-4%. Our postulation is that this variation of CR intensity is related to the relativistic effect of the muon decay, and is an indication of the height of the mid-level pressure distribution. The phenomenon should be further investigated for possible application in weather forecasting and better understanding of the phenomenon could be of use in differentiating the atmospheric effect and the solar effects in CR data. (author)

  11. The need for standardisation of peak flow charts

    OpenAIRE

    Reddel, H; Vincent, S; Civitico, J

    2005-01-01

    Peak expiratory flow (PEF) monitoring is recommended in asthma guidelines as a tool for assessing severity, monitoring response to treatment, detecting exacerbations, identifying triggers, and providing objective justification for treatment to the patient, but some clinicians have expressed concerns about its relevance in the management of asthma. We have identified a sevenfold variation in the scale of existing PEF charts, with resulting wide variation in the appearance of the same PEF date ...

  12. Effect of Variations in Long-Duration Rainfall Intensity on Unsaturated Slope Stability

    Directory of Open Access Journals (Sweden)

    Hsin-Fu Yeh

    2018-04-01

    Full Text Available In recent years, many scientific methods have been used to prove that the Earth’s climate is changing. Climate change can affect rainfall patterns, which can in turn affect slope safety. Therefore, this study analyzed the effects of climate change on rainfall patterns from the perspective of rainfall intensity. This analysis was combined with numerical model analysis to examine the rainfall patterns of the Zengwen reservoir catchment area and its effects on slope stability. In this study, the Mann–Kendall test and the Theil–Sen estimator were used to analyze the rainfall records of rainfall stations at Da-Dong-Shan, Ma-To-Shan, and San-Jiao-Nan-Shan. The rainfall intensity of the Zengwen reservoir catchment area showed an increasing trend from 1990–2016. In addition, the analysis results of rainfall intensity trends were used for qualitative analysis of seepage and slope stability. The trend analysis result showed that in the future, from 2017–2100, if the amount of rainfall per hour continues to rise at about 0.1 mm per year, the amount of seepage will increase at the slope surface boundary and significantly change pore water pressure in the soil. As a result, the time of the occurrence of slope instability after the start of rainfall will decrease from 20 to 13 h, and the reduction in the safety coefficient will increase from 32 to 41%. Therefore, to decrease the effects of slope disasters on the safety of the Zengwen reservoir and its surrounding areas, changes in rainfall intensity trends should be considered for slope safety in this region. However, the results of trend analyses were weak and future research is needed using a wider range of precipitation data and detailed hydrological analysis to better predict rainfall pattern variations.

  13. Intensity rankings of plyometric exercises using joint power absorption.

    Science.gov (United States)

    Van Lieshout, Kathryn G; Anderson, Joy G; Shelburne, Kevin B; Davidson, Bradley S

    2014-09-01

    Athletic trainers and physical therapists often progress patients through rehabilitation by selecting plyometric exercises of increasing intensity in preparation for return to sport. The purpose of this study was to quantify the intensity of seven plyometric movements commonly used in lower-extremity rehabilitation by joint-specific peak power absorption and the sum of the peak power. Ten collegiate athletes performed submaximal plyometric exercises in a single test session: vertical jump, forward jump, backward jump, box drop, box jump up, tuck jump, and depth jump. Three-dimensional kinematics and force platform data were collected to generate joint kinetics. Peak power absorption normalized to body mass was calculated at the ankle, knee, and hip, and averaged across repetitions. Joint peak power data were pooled across athletes and summed to obtain the sum of peak power. Movements were ranked from 1 (low) to 7 (high) based on the sum of peak power and joint peak power (ankle, knee, hip). The sum of peak power did not correspond with standard low, medium, and high subjective intensity ratings or joint peak power in all joints. Mixed model analyses revealed significant variance between the sum of peak power and joint peak power ranks in the forward jump, backward jump, box drop, and depth jump (P<0.05), but not in the vertical jump, box jump up, and tuck jump. Results provide intensity rankings that can be used directly by athletic trainers and physical therapists in developing protocols for rehabilitation specific to the injured joint. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. New Late Neolithic (c. 7000-5000 BC) archeointensity data from Syria. Reconstructing 9000 years of archeomagnetic field intensity variations in the Middle East

    Science.gov (United States)

    Gallet, Yves; Molist Montaña, Miquel; Genevey, Agnès; Clop García, Xavier; Thébault, Erwan; Gómez Bach, Anna; Le Goff, Maxime; Robert, Béatrice; Nachasova, Inga

    2015-01-01

    We present new archeomagnetic intensity data from two Late Neolithic archeological sites (Tell Halula and Tell Masaïkh) in Syria. These data, from 24 groups of potsherds encompassing 15 different time levels, are obtained using the Triaxe experimental protocol, which takes into account both the thermoremanent magnetization anisotropy and cooling rate effects on intensity determinations. They allow us to recover the geomagnetic intensity variations in the Middle East, between ∼7000 BC and ∼5000 BC, i.e. during the so-called pre-Halaf, proto-Halaf, Halaf and Halaf-Ubaid Transitional cultural phases. The data are compared with previous archeointensity results of similar ages from Northern Iraq (Yarim Tepe II and Tell Sotto) and Bulgaria. We find that previous dating of the Iraqi material was in error. When corrected, all northern Mesopotamian data show a relatively good consistency and also reasonably match with the Bulgarian archeointensity dataset. Using a compilation of available data, we construct a geomagnetic field intensity variation curve for the Middle East encompassing the past 9000 years, which makes it presently the longest known regional archeomagnetic intensity record. We further use this compilation to constrain variations in dipole field moment over most of the Holocene. In particular, we discuss the possibility that a significant dipole moment maximum occurred during the third millennium BC, which cannot easily be identified in available time-varying global geomagnetic field reconstructions.

  15. Cryptosporidium and Giardia in Danish organic pig farms: seasonal and age-related variation in prevalence, infection intensity and species/genotypes

    DEFF Research Database (Denmark)

    Petersen, Heidi Huus; Jianmin, Wang; Katakam, Kiran K.

    2015-01-01

    Although pigs are commonly infected with Cryptosporidium spp. and Giardia duodenalis, including potentially zoonotic species or genotypes, little is known about age-related infection levels, seasonal differences and genetic variation in naturally infected pigs raised in organic management systems....... Therefore, the current study was conducted to assess seasonal and age-related variations in prevalence and infection intensity of Cryptosporidium and Giardia, evaluate zoonotic potential and uncover correlations between species/genotypes, infection intensity and faecal consistency. Shedding of oocysts...... and cysts ((oo-) cysts) was monitored at quarterly intervals (September 2011 to June 2012) in piglets (n=152), starter pigs (n=234), fatteners (n=230) and sows (n=240) from three organic farms in Denmark. (Oo-) cysts were quantified by immunofluorescence microscopy; and 56/75 subsamples from Cryptosporidium...

  16. The Peak Pairs algorithm for strain mapping from HRTEM images

    Energy Technology Data Exchange (ETDEWEB)

    Galindo, Pedro L. [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain)], E-mail: pedro.galindo@uca.es; Kret, Slawomir [Institute of Physics, PAS, AL. Lotnikow 32/46, 02-668 Warsaw (Poland); Sanchez, Ana M. [Departamento de Ciencia de los Materiales e Ing. Metalurgica y Q. Inorganica, Facultad de Ciencias, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain); Laval, Jean-Yves [Laboratoire de Physique du Solide, UPR5 CNRS-ESPCI, Paris (France); Yanez, Andres; Pizarro, Joaquin; Guerrero, Elisa [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain); Ben, Teresa; Molina, Sergio I. [Departamento de Ciencia de los Materiales e Ing. Metalurgica y Q. Inorganica, Facultad de Ciencias, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain)

    2007-11-15

    Strain mapping is defined as a numerical image-processing technique that measures the local shifts of image details around a crystal defect with respect to the ideal, defect-free, positions in the bulk. Algorithms to map elastic strains from high-resolution transmission electron microscopy (HRTEM) images may be classified into two categories: those based on the detection of peaks of intensity in real space and the Geometric Phase approach, calculated in Fourier space. In this paper, we discuss both categories and propose an alternative real space algorithm (Peak Pairs) based on the detection of pairs of intensity maxima in an affine transformed space dependent on the reference area. In spite of the fact that it is a real space approach, the Peak Pairs algorithm exhibits good behaviour at heavily distorted defect cores, e.g. interfaces and dislocations. Quantitative results are reported from experiments to determine local strain in different types of semiconductor heterostructures.

  17. Pigment variations in Emiliania huxleyi (CCMP370) as a response to changes in light intensity or quality.

    Science.gov (United States)

    Garrido, José L; Brunet, Christophe; Rodríguez, Francisco

    2016-12-01

    Many studies on photoacclimation examine the pigment responses to changes in light intensity, but variations in light climate in the aquatic environment are also related to changes in spectral composition. We have employed a high-performance liquid chromatography method with improved resolution towards chlorophyll c and fucoxanthin-related xanthophylls to examine the pigment composition of Emiliania huxleyi CCMP 370 under different light intensities and spectral qualities. To maintain its photosynthetic performance, E. huxleyi CCMP370 promotes drastic pigment changes that can be either the interconversion of pigments in pools with the same basic chromophoric structure (Fucoxanthin type or chlorophyll c type), or the ex novo synthesis (Diatoxanthin). These changes are linked either to variations in light quality (Fucoxanthin related xanthophylls) or in light intensity (chlorophyll c 3 /Monovinyl chlorophyll c 3 , Diadinoxanthin/Diatoxanthin, β,ɛ-carotene/ β,β-carotene). Fucoxanthin and 19'-hexanoyloxyfucoxanthin proportions were highly dependent on spectral conditions. Whereas Fucoxanthin dominated in green and red light, 19'-hexanoyloxyfucoxanthin prevailed under blue spectral conditions. Our results suggest that the huge pigment diversity enhanced the photoacclimative capacities of E. huxleyi to efficiently perform under changing light environments. The ubiquity and success in the global ocean as well as the capacity of E. huxleyi to form large surface blooms might be associated to the plasticity described here. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.

  18. SPANISH PEAKS WILDERNESS STUDY AREA, COLORADO.

    Science.gov (United States)

    Budding, Karin E.; Kluender, Steven E.

    1984-01-01

    A geologic and geochemical investigation and a survey of mines and prospects were conducted to evaluate the mineral-resource potential of the Spanish Peaks Wilderness Study Area, Huerfano and Las Animas Counties, in south-central Colorado. Anomalous gold, silver, copper, lead, and zinc concentrations in rocks and in stream sediments from drainage basins in the vicinity of the old mines and prospects on West Spanish Peak indicate a substantiated mineral-resource potential for base and precious metals in the area surrounding this peak; however, the mineralized veins are sparse, small in size, and generally low in grade. There is a possibility that coal may underlie the study area, but it would be at great depth and it is unlikely that it would have survived the intense igneous activity in the area. There is little likelihood for the occurrence of oil and gas because of the lack of structural traps and the igneous activity.

  19. Accurate LC peak boundary detection for ¹⁶O/¹⁸O labeled LC-MS data.

    Science.gov (United States)

    Cui, Jian; Petritis, Konstantinos; Tegeler, Tony; Petritis, Brianne; Ma, Xuepo; Jin, Yufang; Gao, Shou-Jiang S J; Zhang, Jianqiu Michelle

    2013-01-01

    In liquid chromatography-mass spectrometry (LC-MS), parts of LC peaks are often corrupted by their co-eluting peptides, which results in increased quantification variance. In this paper, we propose to apply accurate LC peak boundary detection to remove the corrupted part of LC peaks. Accurate LC peak boundary detection is achieved by checking the consistency of intensity patterns within peptide elution time ranges. In addition, we remove peptides with erroneous mass assignment through model fitness check, which compares observed intensity patterns to theoretically constructed ones. The proposed algorithm can significantly improve the accuracy and precision of peptide ratio measurements.

  20. The road to gold: training and peaking characteristics in the year prior to a gold medal endurance performance.

    Science.gov (United States)

    Tønnessen, Espen; Sylta, Øystein; Haugen, Thomas A; Hem, Erlend; Svendsen, Ida S; Seiler, Stephen

    2014-01-01

    To describe training variations across the annual cycle in Olympic and World Champion endurance athletes, and determine whether these athletes used tapering strategies in line with recommendations in the literature. Eleven elite XC skiers and biathletes (4 male; 28±1 yr, 85±5 mL x min(-1) x kg(-1) VO2max, 7 female, 25±4 yr, 73±3 mL x min(-1) x kg(-1) VO2max) reported one year of day-to-day training leading up to the most successful competition of their career. Training data were divided into periodization and peaking phases and distributed into training forms, intensity zones and endurance activity forms. Athletes trained ∼800 h/500 sessions x year(-1), including ∼500 h x year(-1) of sport-specific training. Ninety-four percent of all training was executed as aerobic endurance training. Of this, ∼90% was low intensity training (LIT, below the first lactate threshold) and 10% high intensity training (HIT, above the first lactate threshold) by time. Categorically, 23% of training sessions were characterized as HIT with primary portions executed at or above the first lactate turn point. Training volume and specificity distribution conformed to a traditional periodization model, but absolute volume of HIT remained stable across phases. However, HIT training patterns tended to become more polarized in the competition phase. Training volume, frequency and intensity remained unchanged from pre-peaking to peaking period, but there was a 32±15% (Pphase. The annual training data for these Olympic and World champion XC skiers and biathletes conforms to previously reported training patterns of elite endurance athletes. During the competition phase, training became more sport-specific, with 92% performed as XC skiing. However, they did not follow suggested tapering practice derived from short-term experimental studies. Only three out of 11 athletes took a rest day during the final 5 days prior to their most successful competition.

  1. Does team lifting increase the variability in peak lumbar compression in ironworkers?

    NARCIS (Netherlands)

    Faber, Gert; Visser, Steven; van der Molen, Henk F.; Kuijer, P. Paul F. M.; Hoozemans, Marco J. M.; van Dieën, Jaap H.; Frings-Dresen, Monique H. W.

    2012-01-01

    Ironworkers frequently perform heavy lifting tasks in teams of two or four workers. Team lifting could potentially lead to a higher variation in peak lumbar compression forces than lifts performed by one worker, resulting in higher maximal peak lumbar compression forces. This study compared

  2. Interspecific variation in the relationship between clutch size, laying date and intensity of urbanization in four species of hole-nesting birds.

    Science.gov (United States)

    Vaugoyeau, Marie; Adriaensen, Frank; Artemyev, Alexandr; Bańbura, Jerzy; Barba, Emilio; Biard, Clotilde; Blondel, Jacques; Bouslama, Zihad; Bouvier, Jean-Charles; Camprodon, Jordi; Cecere, Francesco; Charmantier, Anne; Charter, Motti; Cichoń, Mariusz; Cusimano, Camillo; Czeszczewik, Dorota; Demeyrier, Virginie; Doligez, Blandine; Doutrelant, Claire; Dubiec, Anna; Eens, Marcel; Eeva, Tapio; Faivre, Bruno; Ferns, Peter N; Forsman, Jukka T; García-Del-Rey, Eduardo; Goldshtein, Aya; Goodenough, Anne E; Gosler, Andrew G; Grégoire, Arnaud; Gustafsson, Lars; Harnist, Iga; Hartley, Ian R; Heeb, Philipp; Hinsley, Shelley A; Isenmann, Paul; Jacob, Staffan; Juškaitis, Rimvydas; Korpimäki, Erkki; Krams, Indrikis; Laaksonen, Toni; Lambrechts, Marcel M; Leclercq, Bernard; Lehikoinen, Esa; Loukola, Olli; Lundberg, Arne; Mainwaring, Mark C; Mänd, Raivo; Massa, Bruno; Mazgajski, Tomasz D; Merino, Santiago; Mitrus, Cezary; Mönkkönen, Mikko; Morin, Xavier; Nager, Ruedi G; Nilsson, Jan-Åke; Nilsson, Sven G; Norte, Ana C; Orell, Markku; Perret, Philippe; Perrins, Christopher M; Pimentel, Carla S; Pinxten, Rianne; Richner, Heinz; Robles, Hugo; Rytkönen, Seppo; Senar, Juan Carlos; Seppänen, Janne T; Pascoal da Silva, Luis; Slagsvold, Tore; Solonen, Tapio; Sorace, Alberto; Stenning, Martyn J; Tryjanowski, Piotr; von Numers, Mikael; Walankiewicz, Wieslaw; Møller, Anders Pape

    2016-08-01

    The increase in size of human populations in urban and agricultural areas has resulted in considerable habitat conversion globally. Such anthropogenic areas have specific environmental characteristics, which influence the physiology, life history, and population dynamics of plants and animals. For example, the date of bud burst is advanced in urban compared to nearby natural areas. In some birds, breeding success is determined by synchrony between timing of breeding and peak food abundance. Pertinently, caterpillars are an important food source for the nestlings of many bird species, and their abundance is influenced by environmental factors such as temperature and date of bud burst. Higher temperatures and advanced date of bud burst in urban areas could advance peak caterpillar abundance and thus affect breeding phenology of birds. In order to test whether laying date advance and clutch sizes decrease with the intensity of urbanization, we analyzed the timing of breeding and clutch size in relation to intensity of urbanization as a measure of human impact in 199 nest box plots across Europe, North Africa, and the Middle East (i.e., the Western Palearctic) for four species of hole-nesters: blue tits (Cyanistes caeruleus), great tits (Parus major), collared flycatchers (Ficedula albicollis), and pied flycatchers (Ficedula hypoleuca). Meanwhile, we estimated the intensity of urbanization as the density of buildings surrounding study plots measured on orthophotographs. For the four study species, the intensity of urbanization was not correlated with laying date. Clutch size in blue and great tits does not seem affected by the intensity of urbanization, while in collared and pied flycatchers it decreased with increasing intensity of urbanization. This is the first large-scale study showing a species-specific major correlation between intensity of urbanization and the ecology of breeding. The underlying mechanisms for the relationships between life history and

  3. A beam-synchronous gated peak-detector for the LHC beam observation system

    CERN Document Server

    Levens, T E; Wehrle, U

    2013-01-01

    Measurements of the bunch peak amplitude using the longitudinal wideband wall-current monitor are a vital tool used in the Large Hadron Collider (LHC) beam observation system. These peak-detected measurements can be used to diagnose bunch shape oscillations, for example coherent quadrupole oscillations, that occur at injection and during beam manipulations. Peak-detected Schottky diagnostics can also be used to obtain the synchrotron frequency distribution and other parameters from a bunched beam under stable conditions. For the LHC a beam-synchronous gated peak detector has been developed to allow individual bunches to be monitored without the influence of other bunches circulating in the machine. The requirement for the observation of both low intensity pilot bunches and high intensity bunches for physics requires a detector front-end with a high bandwidth and a large dynamic range while the usage for Schottky measurements requires low noise electronics. This paper will present the design of this detector s...

  4. Neurofeedback training for peak performance

    OpenAIRE

    Marek Graczyk; Maria Pąchalska; Artur Ziółkowski; Grzegorz Mańko; Beata Łukaszewska; Kazimierz Kochanowicz; Andrzej Mirski; Iurii D. Kropotov

    2014-01-01

    [b]aim[/b]. One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneou...

  5. Solar cycle variation of cosmic ray intensity along with interplanetary and solar wind plasma parameters

    International Nuclear Information System (INIS)

    Mishra, R.K.; Tiwari, S.; Agarwal, R.

    2008-01-01

    Galactic cosmic rays are modulated at their propagation in the heliosphere by the effect of the large-scale structure of the interplanetary medium. A comparison of the variations in the cosmic ray intensity data obtained by neutron monitoring stations with those in geomagnetic disturbance, solar wind velocity (V), interplanetary magnetic field (B), and their product (V , B) near the Earth for the period 1964-2004 has been presented so as to establish a possible correlation between them. We used the hourly averaged cosmic ray counts observed with the neutron monitor in Moscow. It is noteworthy that a significant negative correlation has been observed between the interplanetary magnetic field, product (V , B) and cosmic ray intensity during the solar cycles 21 and 22. The solar wind velocity has a good positive correlation with cosmic ray intensity during solar cycle 21, whereas it shows a weak correlation during cycles 20, 22 and 23. The interplanetary magnetic field shows a weak negative correlation with cosmic rays for solar cycle 20, and a good anti-correlation for solar cycles 21-23 with the cosmic ray intensity, which, in turn, shows a good positive correlation with disturbance time index (Dst) during solar cycles 21 and 22, and a weak correlation for cycles 20 and 23. (Authors)

  6. Seasonal variation in the intensity of movements by the estuarine dolphin, Sotalia guianensis (Cetacea: Delphinidae, in the North Bay, Santa Catarina Island

    Directory of Open Access Journals (Sweden)

    Paulo César Simões-Lopes

    2004-05-01

    Full Text Available The resident population of estuarine dolphins (Sotalia guianensis in the North Bay, Santa Catarina Island, southern Brazil, was studied from September 2001 until July 2003 through periodical boat surveys. Using focal-group and sequential sampling, information such as geographical position and behavioral patterns were registered at 5-minute intervals. All the information collected was insert in a GIS database of the study area. Since patterns of seasonal variation concerning home range and behavior had been established in previous work, we aimed at evaluating the existence of seasonal intensity of movements, therefore strengthening the proposed hypothesis of higher spatial requirements when food resources are low. The daily mean speed of the dolphin’s group was used as an index of the intensity of movements, and its seasonal variation throughout the study period was analyzed. We found a statistically significant seasonal variation in the intensity of movement. The dolphins tended to move more in the cold seasons, in contrast with the hot seasons when the dolphins tended to move less. Thus, previous studies are corroborated, supporting the hypothesis og higher spatial requirements when there are fewer food resources.

  7. Four Weeks of Off-Season Training Improves Peak Oxygen Consumption in Female Field Hockey Players

    Directory of Open Access Journals (Sweden)

    Lindsey T. Funch

    2017-11-01

    Full Text Available The purpose of the study was to examine the changes in peak oxygen consumption ( V ˙O2peak and running economy (RE following four-weeks of high intensity training and concurrent strength and conditioning during the off-season in collegiate female field hockey players. Fourteen female student-athletes (age 19.29 ± 0.91 years were divided into two training groups, matched from baseline V ˙O2peak: High Intensity Training (HITrun; n = 8 and High Intensity Interval Training (HIIT; n = 6. Participants completed 12 training sessions. HITrun consisted of 30 min of high-intensity running, while HIIT consisted of a series of whole-body high intensity Tabata-style intervals (75–85% of age predicted maximum heart rate for a total of four minutes. In addition to the interval training, the off-season training included six resistance training sessions, three team practices, and concluded with a team scrimmage. V ˙O2peak was measured pre- and post-training to determine the effectiveness of the training program. A two-way mixed (group × time ANOVA showed a main effect of time with a statistically significant difference in V ˙O2peak from pre- to post-testing, F(1, 12 = 12.657, p = 0.004, partial η2 = 0.041. Average (±SD V ˙O2peak increased from 44.64 ± 3.74 to 47.35 ± 3.16 mL·kg−1·min−1 for HIIT group and increased from 45.39 ± 2.80 to 48.22 ± 2.42 mL·kg−1·min−1 for HITrun group. Given the similar improvement in aerobic power, coaches and training staff may find the time saving element of HIIT-type conditioning programs attractive.

  8. Relaxation peak near 200 K in NiTi alloy

    Science.gov (United States)

    Zhu, J. S.; Schaller, R.; Benoit, W.

    1989-10-01

    Internal friction (IF), frequency ( f), electrical resistance ( R) and zero point movement of the torsion pendulum (ɛ) have been measured in near equi-atomic NiTi alloy in order to clarify the mechanism for the relaxation peak near 200 K. The height of the relaxation peak decreases successively with thermal cycling and settles down to a lower stable value in running 15 cycles. However, the electrical resistance of the sample shows a variation in contrast with the internal friction. Both of them will return to the initial state after a single annealing at 773 K for 1 h. The probable mechanism of this relaxation peak was discussed.

  9. Active inductor shunt peaking in high-speed VCSEL driver design

    CERN Document Server

    Liang, Futian; Hou, Suen; Liu, Chonghan; Liu, Tiankuan; Su, Da-Shung; Teng, Ping-Kun; Xiang, Annie; Ye, Jingbo; Jin, Ge

    2013-01-01

    An all transistor active inductor shunt peaking structure has been used in a prototype of 8-Gbps high-speed VCSEL driver which is designed for the optical link in ATLAS liquid Argon calorimeter upgrade. The VCSEL driver is fabricated in a commercial 0.25-um Silicon-on-Sapphire (SoS) CMOS process for radiation tolerant purpose. The all transistor active inductor shunt peaking is used to overcome the bandwidth limitation from the CMOS process. The peaking structure has the same peaking effect as the passive one, but takes a small area, does not need linear resistors and can overcome the process variation by adjust the peaking strength via an external control. The design has been tapped out, and the prototype has been proofed by the preliminary electrical test results and bit error ratio test results. The driver achieves 8-Gbps data rate as simulated with the peaking. We present the all transistor active inductor shunt peaking structure, simulation and test results in this paper.

  10. From Modeling of Plasticity in Single-Crystal Superalloys to High-Resolution X-rays Three-Crystal Diffractometer Peaks Simulation

    Science.gov (United States)

    Jacques, Alain

    2016-12-01

    The dislocation-based modeling of the high-temperature creep of two-phased single-crystal superalloys requires input data beyond strain vs time curves. This may be obtained by use of in situ experiments combining high-temperature creep tests with high-resolution synchrotron three-crystal diffractometry. Such tests give access to changes in phase volume fractions and to the average components of the stress tensor in each phase as well as the plastic strain of each phase. Further progress may be obtained by a new method making intensive use of the Fast Fourier Transform, and first modeling the behavior of a representative volume of material (stress fields, plastic strain, dislocation densities…), then simulating directly the corresponding diffraction peaks, taking into account the displacement field within the material, chemical variations, and beam coherence. Initial tests indicate that the simulated peak shapes are close to the experimental ones and are quite sensitive to the details of the microstructure and to dislocation densities at interfaces and within the soft γ phase.

  11. Modeling the probability distribution of peak discharge for infiltrating hillslopes

    Science.gov (United States)

    Baiamonte, Giorgio; Singh, Vijay P.

    2017-07-01

    Hillslope response plays a fundamental role in the prediction of peak discharge at the basin outlet. The peak discharge for the critical duration of rainfall and its probability distribution are needed for designing urban infrastructure facilities. This study derives the probability distribution, denoted as GABS model, by coupling three models: (1) the Green-Ampt model for computing infiltration, (2) the kinematic wave model for computing discharge hydrograph from the hillslope, and (3) the intensity-duration-frequency (IDF) model for computing design rainfall intensity. The Hortonian mechanism for runoff generation is employed for computing the surface runoff hydrograph. Since the antecedent soil moisture condition (ASMC) significantly affects the rate of infiltration, its effect on the probability distribution of peak discharge is investigated. Application to a watershed in Sicily, Italy, shows that with the increase of probability, the expected effect of ASMC to increase the maximum discharge diminishes. Only for low values of probability, the critical duration of rainfall is influenced by ASMC, whereas its effect on the peak discharge seems to be less for any probability. For a set of parameters, the derived probability distribution of peak discharge seems to be fitted by the gamma distribution well. Finally, an application to a small watershed, with the aim to test the possibility to arrange in advance the rational runoff coefficient tables to be used for the rational method, and a comparison between peak discharges obtained by the GABS model with those measured in an experimental flume for a loamy-sand soil were carried out.

  12. Interobserver Delineation variation using CT versus combined CT + MRI in intensity- modulated radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Villeirs, G.M.; Verstraete, K.L.; Vaerenbergh, K. van; Vakaet, L.; Bral, S.; Claus, F.; Neve, W.J. de; Meerleer, G.O. de

    2005-01-01

    Purpose: to quantify interobserver variation of prostate and seminal vesicle delineations using CT only versus CT + MRI in consensus reading with a radiologist. Material and methods: the prostate and seminal vesicles of 13 patients treated with intensity-modulated radiotherapy for prostatic adenocarcinoma were retrospectively delineated by three radiation oncologists on CT only and on CT + MRI in consensus reading with a radiologist. The volumes and margin positions were calculated and intermodality and interobserver variations were assessed for the clinical target volume (CTV), seminal vesicles, prostate and three prostatic subdivisions (apical, middle and basal third). Results: using CT + MRI as compared to CT alone, the mean CTV, prostate and seminal vesicle volumes significantly decreased by 6.54%, 5.21% and 10.47%, respectively. More importantly, their standard deviations significantly decreased by 63.06%, 62.65% and 44.83%, respectively. The highest level of variation was found at the prostatic apex, followed by the prostatic base and seminal vesicles. Conclusion: addition of MRI to CT in consensus reading with a radiologist results in a moderate decrease of the CTV, but an important decrease of the interobserver delineation variation, especially at the prostatic apex. (orig.)

  13. Within-session responses to high-intensity interval training in spinal cord injury.

    Science.gov (United States)

    Astorino, Todd Anthony; Thum, Jacob S

    2018-02-01

    Completion of high-intensity interval training (HIIT) increases maximal oxygen uptake and health status, yet its feasibility in persons with spinal cord injury is unknown. To compare changes in cardiorespiratory and metabolic variables between two interval training regimes and moderate intensity exercise. Nine adults with spinal cord injury (duration = 6.8 ± 6.2 year) initially underwent determination of peak oxygen uptake. During subsequent sessions, they completed moderate intensity exercise, HIIT, or sprint interval training. Oxygen uptake, heart rate, and blood lactate concentration were measured. Oxygen uptake and heart rate increased (p  0.05) to moderate intensity exercise. Peak oxygen uptake and heart rate were higher (p HIIT (90% peak oxygen uptake and 99% peak heart rate) and sprint interval training (80% peak oxygen uptake and 96% peak heart rate) versus moderate intensity exercise. Despite a higher intensity and peak cardiorespiratory strain, all participants preferred interval training versus moderate exercise. Examining long-term efficacy and feasibility of interval training in this population is merited, considering that exercise intensity is recognized as the most important variable factor of exercise programming to optimize maximal oxygen uptake. Implications for Rehabilitation Spinal cord injury (SCI) reduces locomotion which impairs voluntary physical activity, typically resulting in a reduction in peak oxygen uptake and enhanced chronic disease risk. In various able-bodied populations, completion of high-intensity interval training (HIIT) has been consistently reported to improve cardiorespiratory fitness and other health-related outcomes, although its efficacy in persons with SCI is poorly understood. Data from this study in 9 men and women with SCI show similar changes in oxygen uptake and heart in response to HIIT compared to a prolonged bout of aerobic exercise, although peak values were higher in response to HIIT. Due to

  14. Internal friction peaks observed in explosively deformed polycrystalline Mo, Nb, and Cu

    Science.gov (United States)

    Rieu, G. E.; Grimes, H. H.; Romain, J. P.; Defouquet, J.

    1974-01-01

    Explosive deformation (50 kbar range) induced, in Cu, Mo and Nb, internal friction peaks identical to those observed after large normal deformation. The variation of the peaks with pressure for Mo and Nb lead to an explanation of these processes in terms of double kink generation in screw and edge dislocations.

  15. Comparative LC-MS: A landscape of Peaks and Valleys

    NARCIS (Netherlands)

    America, A.H.P.; Cordewener, J.H.G.

    2008-01-01

    Quantitative proteomics approaches using stable isotopes are well-known and used in many labs nowadays. More recently, high resolution quantitative approaches are reported that rely on LC-MS quantitation of peptide concentrations by comparing peak intensities between multiple runs obtained by

  16. Escape peak ratios in silicon X-ray charge coupled devices (CCDs)

    International Nuclear Information System (INIS)

    McCarthy, K.J.; Owens, A.; Keay, A.

    1997-01-01

    The intensity of the escape peak from the CCDs developed for the Joint European X-ray Telescope (JET-X) has been investigated over the energy range 2-10 keV. Both measured and calculated escape peak ratios (i.e., the ratio of counts in the escape peak to the sum of the counts in the escape and main peaks) are found to be in excellent agreement for all event sizes (i.e., single pixel events, 1 and 2 pixel events, etc.). Using a Monte Carlo simulation the escape peak ratio has been investigated as a function of pixel size and depletion depth. For completeness, we list the energy dependent parameterised forms for five CCDs used in three major astronomy missions. (orig.)

  17. CLASP/SJ Observations of Rapid Time Variations in the Ly α Emission in a Solar Active Region

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Shin-nosuke [Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, 3-1-1 Yoshinodai, Chuo-ku, Sagamihara, Kanagawa 252–5210 (Japan); Kubo, Masahito; Katsukawa, Yukio; Kano, Ryouhei; Narukage, Noriyuki; Ishikawa, Ryohko; Bando, Takamasa [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Winebarger, Amy; Kobayashi, Ken [NASA Marshall Space Flight Center, Huntsville, AL 35812 (United States); Trujillo Bueno, Javier [Instituto de Astrofísica de Canarias, E-38205 La Laguna, Tenerife (Spain); Auchère, Frédéric, E-mail: s.ishikawa@solar.isas.jaxa.jp [Institut d’Astrophysique Spatiale, CNRS/Univ. Paris-Sud 11, Bätiment 121, F-91405 Orsay (France)

    2017-09-10

    The Chromospheric Ly α SpectroPolarimeter (CLASP) is a sounding rocket experiment launched on 2015 September 3 to investigate the solar chromosphere and transition region. The slit-jaw (SJ) optical system captured Ly α images with a high time cadence of 0.6 s. From the CLASP/SJ observations, many variations in the solar chromosphere and transition region emission with a timescale of <1 minute were discovered. In this paper, we focus on the active region within the SJ field of view and investigate the relationship between short (<30 s) temporal variations in the Ly α emission and the coronal structures observed by Solar Dynamics Observatory/Atmospheric Imaging Assembly (AIA). We compare the Ly α temporal variations at the coronal loop footpoints observed in the AIA 211 Å (≈2 MK) and AIA 171 Å (≈0.6 MK) channels with those in the regions with bright Ly α features without a clear association with the coronal loop footpoints. We find more short (<30 s) temporal variations in the Ly α intensity in the footpoint regions. Those variations did not depend on the temperature of the coronal loops. Therefore, the temporal variations in the Ly α intensity at this timescale range could be related to the heating of the coronal structures up to temperatures around the sensitivity peak of 171 Å. No signature was found to support the scenario that these Ly α intensity variations were related to the nanoflares. Waves or jets from the lower layers (lower chromosphere or photosphere) are possible causes for this phenomenon.

  18. New Raman-peak at 1850 cm(-1) observed in multiwalled carbon nanotubes produced by hydrogen arc discharge.

    Science.gov (United States)

    Chen, B; Kadowaki, Y; Inoue, S; Ohkohchi, M; Zhao, X; Ando, Y

    2010-06-01

    The new peak (near 1850 cm(-1)) assigned to carbon linear chain included in the centre of very thin innermost multiwalled carbon nanotubes (MWNTs) has been verified by Raman spectroscopy. These MWNTs were produced by dc arc discharge of pure graphite rods in pure hydrogen gas and existed in the cathode deposit. In this paper, we clarified that the new Raman-peaks could also be observed in the cathode deposit including MWNTs produced by hydrogen dc arc discharge using graphite electrode with added Y or La. By changing the quantity of addition (Y or La), dc arc current and pressure of ambient hydrogen gas, the optimum condition to get maximum intensity of the new Raman-peaks was obtained. For the case of 1 wt% La, dc 50 A, H2 pressure of 50 Torr was found to be optimum, and the intensity of new Raman-peak was even higher than the G-band peak. For the case of 1 wt% Y, dc 50 A, H2 pressure of 50 Torr was optimum, but the intensity of new Raman-peak was weaker than the G-band peak. Transmission electron microscopy observation revealed that the crystallinity of MWNTs produced with pure graphite rod was better than those produced with added Y or La.

  19. Free-space optical communications with peak and average constraints: High SNR capacity approximation

    KAUST Repository

    Chaaban, Anas

    2015-09-07

    The capacity of the intensity-modulation direct-detection (IM-DD) free-space optical channel with both average and peak intensity constraints is studied. A new capacity lower bound is derived by using a truncated-Gaussian input distribution. Numerical evaluation shows that this capacity lower bound is nearly tight at high signal-to-noise ratio (SNR), while it is shown analytically that the gap to capacity upper bounds is a small constant at high SNR. In particular, the gap to the high-SNR asymptotic capacity of the channel under either a peak or an average constraint is small. This leads to a simple approximation of the high SNR capacity. Additionally, a new capacity upper bound is derived using sphere-packing arguments. This bound is tight at high SNR for a channel with a dominant peak constraint.

  20. Anomalous decrease in X-ray diffraction intensities of Cu-Ni-Al-Co-Cr-Fe-Si alloy systems with multi-principal elements

    International Nuclear Information System (INIS)

    Yeh, J.-W.; Chang, S.-Y.; Hong, Y.-D.; Chen, S.-K.; Lin, S.-J.

    2007-01-01

    With an aim to understand the great reduction in the X-ray diffraction (XRD) intensities of high-entropy alloys, a series of Cu-Ni-Al-Co-Cr-Fe-Si alloys with systematic addition of principal elements from pure element to seven elements was investigated for quantitative analysis of XRD intensities. The variation of XRD peak intensities of the alloy system is similar to that caused by thermal effect, but the intensities further drop beyond the thermal effect with increasing number of incorporated principal elements. An intrinsic lattice distortion effect caused by the addition of multi-principal elements with different atomic sizes is expected for the anomalous decrease in XRD intensities. The mathematical factor of this distortion effect for the modification of XRD structure factor is formulated analogue to that of thermal effect

  1. Operation manual for EDXRDDA - a software package for Bragg peak analysis of energy dispersive powder X-ray diffraction data

    International Nuclear Information System (INIS)

    Jayaswal, Balhans; Vijaykumar, V.; Momin, S.N.; Sikka, S.K.

    1992-01-01

    EDXRDDA is a software package for analysis of raw data for energy dispersive x-ray diffraction from powder samples. It resolves the spectra into individual peaks by a constrained non-linear least squares method (Hughes and Sexton, 1988). The profile function adopted is the Gaussian/Lorentzian product with the mixing ratio refinable in the program. The program is implemented on an IBM PC and is highly interactive with extensive plotting facilities. This report is a user's guide for running the program. In the first step after inputting the spectra, the full spectra is plotted on the screen. The user then chooses a portion of this for peak resolution. The initial guess for the peak intensity, peak position are input with the help of a cursor or a mouse. Upto twenty peaks can be fitted at a time in an interval of 500 channels. For overlapping peaks, various constraints can be applied. Bragg peaks and fluorescence peaks with different half widths can be handled simultaneously. The program on execution produces a look up table which contains the refined values of the peak position, half width, peak intensity, integrated intensity, and their error estimates of each peak. The program is very general and can also be used for curve fitting of data from many other experiments. (author). 2 refs., 7 figs., 2 appendices

  2. Including dynamic CO2 intensity with demand response

    International Nuclear Information System (INIS)

    Stoll, Pia; Brandt, Nils; Nordström, Lars

    2014-01-01

    Hourly demand response tariffs with the intention of reducing or shifting loads during peak demand hours are being intensively discussed among policy-makers, researchers and executives of future electricity systems. Demand response rates have still low customer acceptance, apparently because the consumption habits requires stronger incentive to change than any proposed financial incentive. An hourly CO 2 intensity signal could give customers an extra environmental motivation to shift or reduce loads during peak hours, as it would enable co-optimisation of electricity consumption costs and carbon emissions reductions. In this study, we calculated the hourly dynamic CO 2 signal and applied the calculation to hourly electricity market data in Great Britain, Ontario and Sweden. This provided a novel understanding of the relationships between hourly electricity generation mix composition, electricity price and electricity mix CO 2 intensity. Load shifts from high-price hours resulted in carbon emission reductions for electricity generation mixes where price and CO 2 intensity were positively correlated. The reduction can be further improved if the shift is optimised using both price and CO 2 intensity. The analysis also indicated that an hourly CO 2 intensity signal can help avoid carbon emissions increases for mixes with a negative correlation between electricity price and CO 2 intensity. - Highlights: • We present a formula for calculating hybrid dynamic CO 2 intensity of electricity generation mixes. • We apply the dynamic CO 2 Intensity on hourly electricity market prices and generation units for Great Britain, Ontario and Sweden. • We calculate the spearman correlation between hourly electricity market price and dynamic CO 2 intensity for Great Britain, Ontario and Sweden. • We calculate carbon footprint of shifting 1 kWh load daily from on-peak hours to off-peak hours using the dynamic CO 2 intensity. • We conclude that using dynamic CO 2 intensity for

  3. Variation in rates of severe retinopathy of prematurity among neonatal intensive care units in the Australian and New Zealand Neonatal Network

    OpenAIRE

    Darlow, B A; Hutchinson, J L; Simpson, J M; Henderson-Smart, D J; Donoghue, D A; Evans, N J

    2005-01-01

    Aim: To analyse variations in rates of severe retinopathy of prematurity (ROP) among neonatal intensive care units (NICUs) in the Australian and New Zealand Neonatal Network (ANZNN), adjusting for sampling variability and for case mix.

  4. Impact on the aquatic environment of hydro-peaking in hydroelectric plants

    International Nuclear Information System (INIS)

    Sabaton, C.; Lauters, F.; Valentin, S.

    1996-01-01

    There are a number of types of hydroelectric installations on French rivers. Some of these intermittently turbine water stored in dammed reservoirs, in order to use available reserves at the most opportune moment for power generation. These plants, run under 'hydro-peaking' management procedures, cause variations in discharge in river sections downstream of the restitution, on a daily or weekly scale. To answer questions concerning the impact of such variations in discharge on the aquatic environment, EDF launched a research program aimed at describing and better understanding the physical and biological phenomena related to hydro-peaking and assessing the possible impact of this type of plant management on French streams. Seven sites subjects to hydro-peaking were studied on rivers with mean flow rates lower than 20 m 3 /s (which corresponds to over 65 % of EDF hydro-peaking sites). Four themes in particular were examined: hydraulic characterization of hydro-peaking, modifications in thermal regime and water quality, response of benthic invertebrates and response of fish populations to hydro-peaking. For fish as well as for invertebrates, the role of the base discharge - in the absence of peaking flow - and that of the morphology of the river bed (and, in particular, the presence of shelter for fish) during periods of strong discharge were clearly highlighted. Impact assessment requires a precise diagnosis of the state of biocenoses. To carry out such a diagnosis, one must reason in terms of species, life phase (particularly the most sensitive phases) and population structure as well as the type of stream and the faunizone involved. A risk assessment is possible by means of simultaneous study of the morphology of the river bed and the response of the signal generated by hydro-peaking in terms of hydrology and physical characteristics downstream of the restitution. (authors)

  5. Robust Peak Recognition in Intracranial Pressure Signals

    Directory of Open Access Journals (Sweden)

    Bergsneider Marvin

    2010-10-01

    Full Text Available Abstract Background The waveform morphology of intracranial pressure pulses (ICP is an essential indicator for monitoring, and forecasting critical intracranial and cerebrovascular pathophysiological variations. While current ICP pulse analysis frameworks offer satisfying results on most of the pulses, we observed that the performance of several of them deteriorates significantly on abnormal, or simply more challenging pulses. Methods This paper provides two contributions to this problem. First, it introduces MOCAIP++, a generic ICP pulse processing framework that generalizes MOCAIP (Morphological Clustering and Analysis of ICP Pulse. Its strength is to integrate several peak recognition methods to describe ICP morphology, and to exploit different ICP features to improve peak recognition. Second, it investigates the effect of incorporating, automatically identified, challenging pulses into the training set of peak recognition models. Results Experiments on a large dataset of ICP signals, as well as on a representative collection of sampled challenging ICP pulses, demonstrate that both contributions are complementary and significantly improve peak recognition performance in clinical conditions. Conclusion The proposed framework allows to extract more reliable statistics about the ICP waveform morphology on challenging pulses to investigate the predictive power of these pulses on the condition of the patient.

  6. Variation and Grey GM(1, 1) Prediction of Melting Peak Temperature of Polypropylene During Ultraviolet Radiation Aging

    Science.gov (United States)

    Chen, K.; Y Zhang, T.; Zhang, F.; Zhang, Z. R.

    2017-12-01

    Grey system theory regards uncertain system in which information is known partly and unknown partly as research object, extracts useful information from part known, and thereby revealing the potential variation rule of the system. In order to research the applicability of data-driven modelling method in melting peak temperature (T m) fitting and prediction of polypropylene (PP) during ultraviolet radiation aging, the T m of homo-polypropylene after different ultraviolet radiation exposure time investigated by differential scanning calorimeter was fitted and predicted by grey GM(1, 1) model based on grey system theory. The results show that the T m of PP declines with the prolong of aging time, and fitting and prediction equation obtained by grey GM(1, 1) model is T m = 166.567472exp(-0.00012t). Fitting effect of the above equation is excellent and the maximum relative error between prediction value and actual value of T m is 0.32%. Grey system theory needs less original data, has high prediction accuracy, and can be used to predict aging behaviour of PP.

  7. Explanation of the surface peak in charge integrated LEIS spectra

    CERN Document Server

    Draxler, M; Taglauer, E; Schmid, K; Gruber, R; Ermolov, S N; Bauer, P

    2003-01-01

    Low energy ion scattering is very surface sensitive if scattered ions are analyzed. By time-of-flight (TOF) techniques, also neutral and charge integrated spectra (ions plus neutrals) can be obtained, which yield information about deeper layers. In the literature, the observation of a more or less pronounced surface peak was reported for charge integrated spectra, the intensity of the surface peak being higher at low energies and for heavy projectiles. Aiming at a more profound physical understanding of this surface peak, we performed TOF-experiments and computer simulations for He projectiles and a copper target. Experiments were done in the range 1-9 keV for a scattering angle of 129 deg. . The simulation was performed using the MARLOWE code for the given experimental parameters and a polycrystalline target. At low energies, a pronounced surface peak was observed, which fades away at higher energies. This peak is quantitatively reproduced by the simulation, and corresponds to scattering from approx 2 atomic...

  8. Chinese emissions peak: Not when, but how

    International Nuclear Information System (INIS)

    Spencer, Thomas; Colombier, Michel; Wang, Xin; Sartor, Oliver; Waisman, Henri

    2016-07-01

    It seems highly likely that China will overachieve its 2020 and 2030 targets, and peak its emissions before 2030 and possibly at a lower level than often assumed. This paper argues that the debate on the timing of the peak is misplaced: what matters is not when by why. For the peak to be seen as a harbinger of deep transformation, it needs to be based on significant macro-economic reform and restructuring, with attendant improvement in energy intensity. The Chinese economic model has been extraordinarily investment and resource intensive, and has driven the growth in GHG emissions. That model is no longer economically or environmentally sustainable. Therefore Chinese policy-makers are faced with a trade-off between slower short-term growth and economic reform, versus supporting short-term growth but slowing economic reform. The outcome will be crucial for the transition to a low-carbon economy. Overall, the 13. FYP (2016-2020) gives the impression of a cautious reflection of the new normal paradigm on the economic front, and a somewhat conservative translation of this shift into the energy and climate targets. Nonetheless, the 13. FYP targets set China well on the way to overachieving its 2020 pledge undertaken at COP15 in Copenhagen, and to potentially overachieving its INDC. It thus seems likely that China will achieve its emissions peak before 2030. However, the crucial question is not when China peaks, but whether the underlying transformation of the Chinese economy and energy system lays the basis for deep decarbonization thereafter. Thorough assessments of the implications of the 'new normal' for Chinese emissions and energy system trajectories, taking into account the link with the Chinese macro-economy, are needed. Scenarios provide a useful framework and should focus on a number of short-term uncertainties. Most energy system and emissions scenarios published today assume a continuity of trends between 2010-2015 and 2015-2020, which is at odds with clear

  9. Peptide Peak Detection for Low Resolution MALDI-TOF Mass Spectrometry.

    Science.gov (United States)

    Yao, Jingwen; Utsunomiya, Shin-Ichi; Kajihara, Shigeki; Tabata, Tsuyoshi; Aoshima, Ken; Oda, Yoshiya; Tanaka, Koichi

    2014-01-01

    A new peak detection method has been developed for rapid selection of peptide and its fragment ion peaks for protein identification using tandem mass spectrometry. The algorithm applies classification of peak intensities present in the defined mass range to determine the noise level. A threshold is then given to select ion peaks according to the determined noise level in each mass range. This algorithm was initially designed for the peak detection of low resolution peptide mass spectra, such as matrix-assisted laser desorption/ionization Time-of-Flight (MALDI-TOF) mass spectra. But it can also be applied to other type of mass spectra. This method has demonstrated obtaining a good rate of number of real ions to noises for even poorly fragmented peptide spectra. The effect of using peak lists generated from this method produces improved protein scores in database search results. The reliability of the protein identifications is increased by finding more peptide identifications. This software tool is freely available at the Mass++ home page (http://www.first-ms3d.jp/english/achievement/software/).

  10. O2 uptake kinetics during exercise at peak O2 uptake.

    Science.gov (United States)

    Scheuermann, Barry W; Barstow, Thomas J

    2003-11-01

    Compared with moderate- and heavy-intensity exercise, the adjustment of O2 uptake (VO2) to exercise intensities that elicit peak VO2 has received relatively little attention. This study examined the VO2 response of 21 young, healthy subjects (25 +/- 6 yr; mean +/- SD) during cycle ergometer exercise to step transitions in work rate (WR) corresponding to 90, 100, and 110% of the peak WR achieved during a preliminary ramp protocol (15-30 W/min). Gas exchange was measured breath by breath and interpolated to 1-s values. VO2 kinetics were determined by use of a two- or three-component exponential model to isolate the time constant (tau2) as representative of VO2 kinetics and the amplitude (Amp) of the primary fast component independent of the appearance of any VO2 slow component. No difference in VO2 kinetics was observed between WRs (tau90 = 24.7 +/- 9.0; tau100 = 22.8 +/- 6.7; tau110 = 21.5 +/- 9.2 s, where subscripts denote percent of peak WR; P > 0.05); nor in a subgroup of eight subjects was tau2 different from the value for moderate-intensity (exercise (tau2 = 25 +/- 12 s, P > 0.05). As expected, the Amp increased with increasing WRs (Amp90 = 2,089 +/- 548; Amp100 = 2,165 +/- 517; Amp110 = 2,225 +/- 559 ml/min; Amp90 vs. Amp110, P exercise, the gain of the Vo2 response (as deltaVO2/DeltaWR) is reduced for exercise transitions in the severe-intensity domain, but the approach to this gain is well described by a common time constant that is invariant across work intensities. The lower deltaVO2/deltaWR may be due to an insufficient adjustment of the cardiovascular and/or pulmonary systems that determine O2 delivery to the exercising muscles or due to recruitment of motor units with lower oxidative capacity, after the onset of exercise in the severe-intensity domain.

  11. Peaking China’s CO2 Emissions: Trends to 2030 and Mitigation Potential

    Directory of Open Access Journals (Sweden)

    Qiang Liu

    2017-02-01

    Full Text Available China has submitted its nationally determined contribution to peak its energy-related emissions around 2030. To understand how China might develop its economy while controlling CO2 emissions, this study surveys a number of recent modeling scenarios that project the country’s economic growth, energy mix, and associated emissions until 2050. Our analysis suggests that China’s CO2 emissions will continue to grow until 2040 or 2050 and will approximately double their 2010 level without additional policy intervention. The alternative scenario, however, suggests that peaking CO2 emissions around 2030 requires the emission growth rate to be reduced by 2% below the reference level. This step would result in a plateau in China’s emissions from 2020 to 2030. This paper also proposed a deep de-carbonization pathway for China that is consistent with China’s goal of peaking emissions by around 2030, which can best be achieved through a combination of improvements in energy and carbon intensities. Our analysis also indicated that the potential for energy intensity decline will be limited over time. Thus, the peaking will be largely dependent on the share of non-fossil fuel energy in primary energy consumption.

  12. The impact of the year-on-year variation in the intensity of solar radiation on the energy intensity of low-energy and passive houses

    Directory of Open Access Journals (Sweden)

    Šubrt Roman

    2017-01-01

    Full Text Available Solar radiation is a significant segment of heat gains in the operation of buildings. The importance of this segment is highlighted by lowering the energy performance of buildings. The current condition of assessment considers the standard values of solar radiation but these are often very different from the fair values. In the contribution it draws attention to not only to on-year variation in solar fluctuations in the intensity of solar radiation and its significant long-term deviation from the standard values but also to the impact to energy building in reliance to its energy intensity. The attention will be focused also to different values in standards valid in the Czech Republic. This specification of energy assessment of buildings is not only necessary to approximate calculations of real state, but mainly because we can expect more disputes about if a building has declared calculating the parameters of a building with nearly zero-energy or passive house.

  13. Solar cycle variations of the energetic H/He intensity ratio at high heliolatitudes and in the ecliptic plane

    Directory of Open Access Journals (Sweden)

    D. Lario

    Full Text Available We study the variability of the heliospheric energetic proton-to-helium abundance ratios during different phases of the solar cycle. We use energetic particle, solar wind, and magnetic field data from the Ulysses, ACE and IMP-8 spacecraft to compare the H/He intensity ratio at high heliographic latitudes and in the ecliptic plane. During the first out-of-ecliptic excursion of Ulysses (1992–1996, the HI-SCALE instrument measured corotating energetic particle intensity enhancements characterized by low values (< 10 of the 0.5–1.0 MeV nucleon-1 H/He intensity ratio. During the second out-of-ecliptic excursion of Ulysses (1999–2002, the more frequent occurrence of solar energetic particle events resulted in almost continuously high (< 20 values of the H/He ratio, even at the highest heliolatitudes reached by Ulysses. Comparison with in-ecliptic measurements from an identical instrument on the ACE spacecraft showed similar H/He values at ACE and Ulysses, suggesting a remarkable uniformity of energetic particle intensities in the solar maximum heliosphere at high heliolatitudes and in the ecliptic plane. In-ecliptic observations of the H/He intensity ratio from the IMP-8 spacecraft show variations between solar maximum and solar minimum similar to those observed by Ulysses at high heliographic latitudes. We suggest that the variation of the H/He intensity ratio throughout the solar cycle is due to the different level of transient solar activity, as well as the different structure and duration that corotating solar wind structures have under solar maximum and solar minimum conditions. During solar minimum, the interactions between the two different types of solar wind streams (slow vs. fast are strong and long-lasting, allowing for a continuous and efficient acceleration of interstellar pickup He +. During solar maximum, transient events of solar origin (characterized by high values of the H/He ratio are able to globally

  14. The different effects of high intensity interval training and moderate intensity interval training for weightlessness countermeasures

    Science.gov (United States)

    Wang, Lin-Jie; Cheng, Tan; Zhi-Li, Li; Hui-juan, Wang; Wen-juan, Chen; Jianfeng, Zhang; Desheng, Wang; Dongbin, Niu; Qi, Zhao; Chengjia, Yang; Yanqing, Wang

    High intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. But the difference between high intensity interval training and moderate intensity interval training (MIIT) in simulated weightlessness still has not been well studied. This study sought to characterize the difference between 6 weeks high intensity interval training and moderate intensity interval training under reduced weight (RW) gait training device and zero-gravity locomotion system (ZLS). Twenty-three subjects (14M/4F, 32.5±4.5 years) volunteered to participate. They were divided into three groups, that were MITT (alternating 2 min at 40% VO _{2} peak and 2 min at 60% VO _{2} peak for 30min, five days per week) RW group (n=8), HITT (alternating 2 min at 40% VO _{2} peak and 2 min at 90% VO _{2} peak for 30min, three days per week) RW group (n=8) and HITT ZLS group (n=7). The Z-axis load used in RW group was 80% body weight (BW) and in ZLS was 100% BW. Cardiopulmonary function was measured before, after 4-week training and after 6-week training. Isokinetic knee extension-flexion test at 60(°) deg/s and 180(°) deg/s were performed before and after the 6-week training, and isometric knee extension-flexion test at 180(°) deg/s was also examined at the same time. It was found that the VO _{2} peaks, metabolic equivalent (MET), Speedmax and respiratory exchange ratio (RER) were significantly increased after 4 and 6-week training in all three groups and no significant group difference were detected. The peak torque at 60(°) deg/s for right knee flexion were significantly increased after 6 week-training in all three groups, and only in HITT RW group the total power at 60(°) deg/s for right knee flexion enhanced. The total power and average power at 60(°) deg/s for right knee extension decreased significantly after 6-week training in all three groups. The peak torque at 60(°) deg/s for right knee extension in MIIT RW group was

  15. An Evaluation of Subseasonal Intensity Variation of the South Asian High in the CMIP5 Models

    Science.gov (United States)

    Shang, W.; Ren, X.

    2017-12-01

    The South Asian High (SAH) is a vital member among the Asian summer monsoon circulations in the upper troposphere located over the Tibetan Plateau and its surrounding areas during boreal summer. This study presents an evaluation of the characteristics of SAH's subseasonal intensity variation simulated by 18 coupled models from the Coupled Model Intercomparison Project (CMIP5). The empirical orthogonal function (EOF) analysis is used on subseasonal anomalies in 100hPa geopotential height over 20°-40°N, 35°-110°E for June, July and August from 1979 to 2005. The first EOF mode from the ERA-Interim (denoted as observation) shows a monopole pattern capturing the strengthening/weakening of SAH. The power spectrum analysis of the corresponding principal component (PC1) time series shows a period about 10-30 days. In general, all the 18 coupled models can reproduce the monopole pattern and its subseasonal oscillation to a certain extent. The four well-simulated models are: ACCESS1-3, HadGEM2-CC, MRI-CGCM3 and BNU-ESM, which EOF1 show strong positive anomalies in the 100hPa geopotential height over the SAH's region and weak negative anomalies in their north side. Lead-lag regression shows that the evolution of the EOF1 from day -12 to +3 in the above four models is also reasonably simulated. In the observation, positive rainfall band moves northward from the equatorial Indian Ocean, the Bay of Bengals and the Western North Pacific to the north of Indian Peninsula, south of Tibetan Plateau and Southeast China, accompanied by the increasing intensity of SAH. In the above four models, the northward movement of anomalous rainfall band can be well reproduced. In the observation, the spatial pattern of anomalies in integrated apparent heat source and integrated apparent moisture sink resemble that of rainfall, thus corresponding to anomalous condensation heat release. The anomalous heating stimulates positive height anomalies with an anomalous anticyclonic circulation to its

  16. Echo 2: observations at Fort Churchill of a 4-keV peak in low-level electron precipitation

    International Nuclear Information System (INIS)

    Arnoldy, R.L.; Hendrickson, R.A.; Winckler, J.R.

    1975-01-01

    The Echo 2 rocket flight launched from Fort Churchill, Manitoba, offered the opportunity to observe high-latitude low-level electron precipitation during quiet magnetic conditions. Although no visual aurora was evident at the time of the flight, an auroral spectrum sharply peaked at a few keV was observed to have intensities from 1 to 2 orders of magnitude lower than peaked spectra typically assoicated with bright auroral forms. There is a growing body of evidence that relates peaked electron spectra to discrete aurora. The Echo 2 observations show that whatever the mechanism for peaking the electron spectrum in and above discrete forms, it operates over a range of precipitation intensities covering nearly 3 orders of magnitude down to subvisual or near subvisual events

  17. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex.

    Science.gov (United States)

    Xie, Shan Juan; Lu, Yu; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2015-07-14

    Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc.) vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs). In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV) normalization method using guided filter based single scale retinex (GFSSR) is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.

  18. Cardiorespiratory fitness modulates the acute flow-mediated dilation response following high-intensity but not moderate-intensity exercise in elderly men.

    Science.gov (United States)

    Bailey, Tom G; Perissiou, Maria; Windsor, Mark; Russell, Fraser; Golledge, Jonathan; Green, Daniel J; Askew, Christopher D

    2017-05-01

    Impaired endothelial function is observed with aging and in those with low cardiorespiratory fitness (V̇o 2peak ). Improvements in endothelial function with exercise training are somewhat dependent on the intensity of exercise. While the acute stimulus for this improvement is not completely understood, it may, in part, be due to the flow-mediated dilation (FMD) response to acute exercise. We examined the hypothesis that exercise intensity alters the brachial (systemic) FMD response in elderly men and is modulated by V̇o 2peak Forty-seven elderly men were stratified into lower (V̇o 2peak = 24.3 ± 2.9 ml·kg -1 ·min -1 ; n = 27) and higher fit groups (V̇o 2peak = 35.4 ± 5.5 ml·kg -1 ·min -1 ; n = 20) after a test of cycling peak power output (PPO). In randomized order, participants undertook moderate-intensity continuous exercise (MICE; 40% PPO) or high-intensity interval cycling exercise (HIIE; 70% PPO) or no-exercise control. Brachial FMD was assessed at rest and 10 and 60 min after exercise. FMD increased after MICE in both groups {increase of 0.86% [95% confidence interval (CI), 0.17-1.56], P = 0.01} and normalized after 60 min. In the lower fit group, FMD was reduced after HIIE [reduction of 0.85% (95% CI, 0.12-1.58), P = 0.02] and remained decreased at 60 min. In the higher fit group, FMD was unchanged immediately after HIIE and increased after 60 min [increase of 1.52% (95% CI, 0.41-2.62), P exercise control, FMD was reduced in both groups after 60 min ( P = 0.05). Exercise intensity alters the acute FMD response in elderly men and V̇o 2peak modulates the FMD response following HIIE but not MICE. The sustained decrease in FMD in the lower fit group following HIIE may represent a signal for vascular adaptation or endothelial fatigue. NEW & NOTEWORTHY This study is the first to show that moderate-intensity continuous cycling exercise increased flow-mediated dilation (FMD) transiently before normalization of FMD after 1 h, irrespective of

  19. Comparative analysis of peak-detection techniques for comprehensive two-dimensional chromatography.

    Science.gov (United States)

    Latha, Indu; Reichenbach, Stephen E; Tao, Qingping

    2011-09-23

    Comprehensive two-dimensional gas chromatography (GC×GC) is a powerful technology for separating complex samples. The typical goal of GC×GC peak detection is to aggregate data points of analyte peaks based on their retention times and intensities. Two techniques commonly used for two-dimensional peak detection are the two-step algorithm and the watershed algorithm. A recent study [4] compared the performance of the two-step and watershed algorithms for GC×GC data with retention-time shifts in the second-column separations. In that analysis, the peak retention-time shifts were corrected while applying the two-step algorithm but the watershed algorithm was applied without shift correction. The results indicated that the watershed algorithm has a higher probability of erroneously splitting a single two-dimensional peak than the two-step approach. This paper reconsiders the analysis by comparing peak-detection performance for resolved peaks after correcting retention-time shifts for both the two-step and watershed algorithms. Simulations with wide-ranging conditions indicate that when shift correction is employed with both algorithms, the watershed algorithm detects resolved peaks with greater accuracy than the two-step method. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. VARIATION IN RESISTIVE FORCE SELECTION DURING BRIEF HIGH INTENSITY CYCLE ERGOMETRY: IMPLICATIONS FOR POWER ASSESSMENT AND PRODUCTION IN ELITE KARATE PRACTITIONERS

    Directory of Open Access Journals (Sweden)

    Julien Steven Baker

    2006-07-01

    Full Text Available The purpose of this study was to measure power values generated in elite karate fighters during brief high intensity cycle ergometry when resistive forces were derived from total - body mass (TBM or fat - free mass (FFM. Male international karate practitioners volunteered as participants (n = 11. Body density was calculated using hydrostatic weighing procedures with fat mass ascertained from body density values. Participants were required to pedal maximally on a cycle ergometer (Monark 864 against randomly assigned loads ranging from 70 g·kg-1 - 95 g·kg-1 (using a TBM or FFM protocol for 8 seconds. The resistive force that produced the highest peak power output (PPO for each protocol was considered optimal. Differences (p 0.05 were observed between time to PPO, or heart rate when the TBM and FFM protocols were compared. The findings of this study suggest that when high intensity cycle ergometer resistive forces are derived from FFM, greater peak powers can be obtained consistently in karate athletes. Resistive forces that relate to the active muscle tissue utilised during this type of exercise may need to be explored in preference to protocols that include both lean and fat masses. The findings have implications for both exercise prescription and the evaluation of experimental results concerning karate athletes

  1. 'J-KAREN' - high intensity, high contrast laser

    International Nuclear Information System (INIS)

    Kiriyama, Hiromitsu; Mori, Michiaki; Nakai, Yoshiki; Okada, Hajime; Sasao, Hajime; Sagisaka, Akito; Ochi, Yoshihiro; Tanaka, Momoko; Kondo, Kiminori; Tateno, Ryo; Sugiyama, Akira; Daido, Hiroyuki; Koike, Masato; Kawanishi, Syunichi; Shimomura, Takuya; Tanoue, Manabu; Wakai, Daisuke; Kondo, Shuji; Kanazawa, Shuhei

    2010-01-01

    We report on the high intensity, high contrast double chirped-pulse amplification (CPA) Ti:sapphire laser system (named J-KAREN). By use of an optical parametric chirped-pulse amplification (OPCPA) preamplifier that is seeded by a cleaned high-energy pulse, a background amplified spontaneous emission (ASE) level of 10 -10 relative to the peak main femtosecond pulse on the picosecond timescales demonstrated with an output energy of 1.7 J and a pulse duration of 30 fs, corresponding to a peak power of 60TW at a 10 Hz repetition rate. This system which uses a cryogenically-cooled Ti:sapphire final amplifier generates focused peak intensity in excess of 10 20 W/cm 2 at a 10 Hz repetition rate. (author)

  2. Relative Biological Effectiveness Variation Along Monoenergetic and Modulated Bragg Peaks of a 62-MeV Therapeutic Proton Beam: A Preclinical Assessment

    International Nuclear Information System (INIS)

    Chaudhary, Pankaj; Marshall, Thomas I.; Perozziello, Francesca M.; Manti, Lorenzo; Currell, Frederick J.; Hanton, Fiona; McMahon, Stephen J.; Kavanagh, Joy N.; Cirrone, Giuseppe Antonio Pablo; Romano, Francesco; Prise, Kevin M.; Schettino, Giuseppe

    2014-01-01

    Purpose: The biological optimization of proton therapy can be achieved only through a detailed evaluation of relative biological effectiveness (RBE) variations along the full range of the Bragg curve. The clinically used RBE value of 1.1 represents a broad average, which disregards the steep rise of linear energy transfer (LET) at the distal end of the spread-out Bragg peak (SOBP). With particular attention to the key endpoint of cell survival, our work presents a comparative investigation of cell killing RBE variations along monoenergetic (pristine) and modulated (SOBP) beams using human normal and radioresistant cells with the aim to investigate the RBE dependence on LET and intrinsic radiosensitvity. Methods and Materials: Human fibroblasts (AG01522) and glioma (U87) cells were irradiated at 6 depth positions along pristine and modulated 62-MeV proton beams at the INFN-LNS (Catania, Italy). Cell killing RBE variations were measured using standard clonogenic assays and were further validated using Monte Carlo simulations and the local effect model (LEM). Results: We observed significant cell killing RBE variations along the proton beam path, particularly in the distal region showing strong dose dependence. Experimental RBE values were in excellent agreement with the LEM predicted values, indicating dose-averaged LET as a suitable predictor of proton biological effectiveness. Data were also used to validate a parameterized RBE model. Conclusions: The predicted biological dose delivered to a tumor region, based on the variable RBE inferred from the data, varies significantly with respect to the clinically used constant RBE of 1.1. The significant RBE increase at the distal end suggests also a potential to enhance optimization of treatment modalities such as LET painting of hypoxic tumors. The study highlights the limitation of adoption of a constant RBE for proton therapy and suggests approaches for fast implementation of RBE models in treatment planning

  3. On dealing with multiple correlation peaks in PIV

    Science.gov (United States)

    Masullo, A.; Theunissen, R.

    2018-05-01

    A novel algorithm to analyse PIV images in the presence of strong in-plane displacement gradients and reduce sub-grid filtering is proposed in this paper. Interrogation windows subjected to strong in-plane displacement gradients often produce correlation maps presenting multiple peaks. Standard multi-grid procedures discard such ambiguous correlation windows using a signal to noise (SNR) filter. The proposed algorithm improves the standard multi-grid algorithm allowing the detection of splintered peaks in a correlation map through an automatic threshold, producing multiple displacement vectors for each correlation area. Vector locations are chosen by translating images according to the peak displacements and by selecting the areas with the strongest match. The method is assessed on synthetic images of a boundary layer of varying intensity and a sinusoidal displacement field of changing wavelength. An experimental case of a flow exhibiting strong velocity gradients is also provided to show the improvements brought by this technique.

  4. Mapping the continuous reciprocal space intensity distribution of X-ray serial crystallography.

    Science.gov (United States)

    Yefanov, Oleksandr; Gati, Cornelius; Bourenkov, Gleb; Kirian, Richard A; White, Thomas A; Spence, John C H; Chapman, Henry N; Barty, Anton

    2014-07-17

    Serial crystallography using X-ray free-electron lasers enables the collection of tens of thousands of measurements from an equal number of individual crystals, each of which can be smaller than 1 µm in size. This manuscript describes an alternative way of handling diffraction data recorded by serial femtosecond crystallography, by mapping the diffracted intensities into three-dimensional reciprocal space rather than integrating each image in two dimensions as in the classical approach. We call this procedure 'three-dimensional merging'. This procedure retains information about asymmetry in Bragg peaks and diffracted intensities between Bragg spots. This intensity distribution can be used to extract reflection intensities for structure determination and opens up novel avenues for post-refinement, while observed intensity between Bragg peaks and peak asymmetry are of potential use in novel direct phasing strategies.

  5. Intensity variation of cosmic rays near the heliospheric current sheet

    International Nuclear Information System (INIS)

    Badruddin, K.S.; Yadav, R.S.; Yadav, N.R.

    1985-01-01

    Cosmic ray intensity variations near the heliospheric current sheet-both above and below it-have been studied during 1964-76. Superposed epoch analysis of the cosmic ray neutron monitor data with respect to sector boundaries (i.e., heliospheric current sheet crossings) has been performed. In this analysis data from neutron monitors well distributed in latitude over the Earth's surface is used. First, this study has been made during the two solar activity minimum periods 1964-65 and 1975-76, using the data from Thule (cut-off rigidity O GV), Deep River (cut-off rigidity 1.02 GV), Rome (cut-off rigidity 6.32 GV) and Huancayo (cut-off rigidity 13.45 GV) neutron monitors. The data is analyzed from Deep River, Rome and Huancayo neutron monitors, for which data is available for the full period (1964-76), by dividing the periods according to the changes in solar activity, interplanetary magnetic field polarity and coronal holes. All these studies have shown a negative gradient with respect to heliomagnetic latitude (current sheet). These results have been discussed in the light of theoretical and observational evidences. Suggestions have been given to overcome the discrepancy between the observational and theoretical results. Further, possible explanations for these observational results have been suggested. (author)

  6. Rainwater runoff retention on an aged intensive green roof.

    Science.gov (United States)

    Speak, A F; Rothwell, J J; Lindley, S J; Smith, C L

    2013-09-01

    Urban areas are characterised by large proportions of impervious surfaces which increases rainwater runoff and the potential for surface water flooding. Increased precipitation is predicted under current climate change projections, which will put further pressure on urban populations and infrastructure. Roof greening can be used within flood mitigation schemes to restore the urban hydrological balance of cities. Intensive green roofs, with their deeper substrates and higher plant biomass, are able to retain greater quantities of runoff, and there is a need for more studies on this less common type of green roof which also investigate the effect of factors such as age and vegetation composition. Runoff quantities from an aged intensive green roof in Manchester, UK, were analysed for 69 rainfall events, and compared to those on an adjacent paved roof. Average retention was 65.7% on the green roof and 33.6% on the bare roof. A comprehensive soil classification revealed the substrate, a mineral soil, to be in good general condition and also high in organic matter content which can increase the water holding capacity of soils. Large variation in the retention data made the use of predictive regression models unfeasible. This variation arose from complex interactions between Antecedant Dry Weather Period (ADWP), season, monthly weather trends, and rainfall duration, quantity and peak intensity. However, significantly lower retention was seen for high rainfall events, and in autumn, which had above average rainfall. The study period only covers one unusually wet year, so a longer study may uncover relationships to factors which can be applied to intensive roofs elsewhere. Annual rainfall retention for Manchester city centre could be increased by 2.3% by a 10% increase in intensive green roof construction. The results of this study will be of particular interest to practitioners implementing greenspace adaptation in temperate and cool maritime climates. Copyright © 2013

  7. Estimating the intensity of ward admission and its effect on emergency department access block.

    Science.gov (United States)

    Luo, Wei; Cao, Jiguo; Gallagher, Marcus; Wiles, Janet

    2013-07-10

    Emergency department access block is an urgent problem faced by many public hospitals today. When access block occurs, patients in need of acute care cannot access inpatient wards within an optimal time frame. A widely held belief is that access block is the end product of a long causal chain, which involves poor discharge planning, insufficient bed capacity, and inadequate admission intensity to the wards. This paper studies the last link of the causal chain-the effect of admission intensity on access block, using data from a metropolitan hospital in Australia. We applied several modern statistical methods to analyze the data. First, we modeled the admission events as a nonhomogeneous Poisson process and estimated time-varying admission intensity with penalized regression splines. Next, we established a functional linear model to investigate the effect of the time-varying admission intensity on emergency department access block. Finally, we used functional principal component analysis to explore the variation in the daily time-varying admission intensities. The analyses suggest that improving admission practice during off-peak hours may have most impact on reducing the number of ED access blocks. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Morphology, surface roughness, electron inelastic and quasi-elastic scattering in elastic peak electron spectroscopy of polymers

    International Nuclear Information System (INIS)

    Lesiak, B.; Kosinski, A.; Nowakowski, R.; Koever, L.; Toth, J.; Varga, D.; Cserny, I.; Sulyok, A.; Gergely, G.

    2006-01-01

    Complete text of publication follows. Elastic peak electron spectroscopy (EPES) deals with the interaction of electrons with atoms of a solid surface, studying the distribution of electrons backscattered elastically. The nearest vicinity of the elastic peak, (low kinetic energy region) reflects both, electron inelastic and quasi-elastic processes. The incident electrons produce surface excitations, inducing surface plasmons with the corresponding loss peaks separated by 1 - 20 eV energy from the elastic peak. Quasi-elastic losses result from the recoil of scattering atoms of different atomic number, Z. The respective energy shift and Doppler broadening of the elastic peak depend on Z, the primary electron energy, E, and the measurement geometry. Quantitative surface analytical application of EPES, such as determination of parameters describing electron transport, requires a comparison of experimental data with corresponding data derived from Monte Carlo (MC) simulation. Several problems occur in EPES studies of polymers. The intensity of elastic peak, considered in quantitative surface analysis, is influenced by both, the inelastic and quasi-elastic scattering processes (especially for hydrogen scattering atoms and primary electron energy above 1000 eV). An additional factor affecting the elastic peak intensity is the surface morphology and roughness. The present work compares the effect of these factors on the elastic peak intensity for selected polymers (polyethylene, polyaniline and polythiophenes). X-ray photoelectron spectroscopy (XPS) and helium pycnometry are applied for deriving the surface atomic composition and the bulk density, while scanning electron microscopy (SEM) and atomic force microscopy (AFM) for determining surface morphology and roughness. According to presented results, the influence of surface morphology and roughness is larger than those of surface excitations or recoil of hydrogen atoms. The component due to recoil of hydrogen atoms can be

  9. Automatic Peak Selection by a Benjamini-Hochberg-Based Algorithm

    KAUST Repository

    Abbas, Ahmed; Kong, Xin-Bing; Liu, Zhi; Jing, Bing-Yi; Gao, Xin

    2013-01-01

    A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR)-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H)-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into p-values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx. © 2013

  10. Automatic Peak Selection by a Benjamini-Hochberg-Based Algorithm

    KAUST Repository

    Abbas, Ahmed

    2013-01-07

    A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR)-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H)-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into p-values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx. © 2013

  11. Variation in Rapa Nui (Easter Island) land use indicates production and population peaks prior to European contact.

    Science.gov (United States)

    Stevenson, Christopher M; Puleston, Cedric O; Vitousek, Peter M; Chadwick, Oliver A; Haoa, Sonia; Ladefoged, Thegn N

    2015-01-27

    Many researchers believe that prehistoric Rapa Nui society collapsed because of centuries of unchecked population growth within a fragile environment. Recently, the notion of societal collapse has been questioned with the suggestion that extreme societal and demographic change occurred only after European contact in AD 1722. Establishing the veracity of demographic dynamics has been hindered by the lack of empirical evidence and the inability to establish a precise chronological framework. We use chronometric dates from hydrated obsidian artifacts recovered from habitation sites in regional study areas to evaluate regional land-use within Rapa Nui. The analysis suggests region-specific dynamics including precontact land use decline in some near-coastal and upland areas and postcontact increases and subsequent declines in other coastal locations. These temporal land-use patterns correlate with rainfall variation and soil quality, with poorer environmental locations declining earlier. This analysis confirms that the intensity of land use decreased substantially in some areas of the island before European contact.

  12. Absolute intensities of supersonic beams

    International Nuclear Information System (INIS)

    Beijerinck, H.C.W.; Habets, A.H.M.; Verster, N.F.

    1977-01-01

    In a molecular beam experiment the center-line intensity I(0) (particles s -1 sterad -1 ) and the flow rate dN/dt (particles s -1 ) of a beam source are important features. To compare the performance of different types of beam sources the peaking factor, kappa, is defined as the ratio kappa=π(I(0)/dN/dt). The factor π is added to normalize to kappa=1 for an effusive source. The ideal peaking factor for the supersonic flow from a nozzle follows from continuum theory. Numerical values of kappa are available. Experimental values of kappa for an argon expansion are presented in this paper, confirming these calculations. The actual center-line intensity of a supersonic beam source with a skimmer is reduced in comparison to this ideal intensity if the skimmer shields part of the virtual source from the detector. Experimental data on the virtual source radius are given enabling one to predict this shielding quantitatively. (Auth.)

  13. Peak Velocity as an Alternative Method for Training Prescription in Mice.

    Science.gov (United States)

    Picoli, Caroline de Carvalho; Romero, Paulo Vitor da Silva; Gilio, Gustavo R; Guariglia, Débora A; Tófolo, Laize P; de Moraes, Solange M F; Machado, Fabiana A; Peres, Sidney B

    2018-01-01

    Purpose: To compare the efficiency of an aerobic physical training program prescribed according to either velocity associated with maximum oxygen uptake (vVO 2max ) or peak running speed obtained during an incremental treadmill test (V peak_K ) in mice. Methods: Twenty male Swiss mice, 60 days old, were randomly divided into two groups with 10 animals each: 1. group trained by vVO 2max (GVO 2 ), 2. group trained by V peak_K (GVP). After the adaptation training period, an incremental test was performed at the beginning of each week to adjust training load and to determine the amount of VO 2 and VCO 2 fluxes consumed, energy expenditure (EE) and run distance during the incremental test. Mice were submitted to 4 weeks of aerobic exercise training of moderate intensity (velocity referring to 70% of vVO 2max and V peak_K ) in a programmable treadmill. The sessions lasted from 30 to 40 min in the first week, to reach 60 min in the fourth week, in order to provide the mice with a moderate intensity exercise, totaling 20 training sessions. Results: Mice demonstrated increases in VO 2max (ml·kg -1 ·min -1 ) (GVO 2 = 49.1% and GVP = 56.2%), V peak_K (cm·s -1 ) (GVO 2 = 50.9% and GVP = 22.3%), EE (ml·kg -0,75 ·min -1 ) (GVO 2 = 39.9% and GVP = 51.5%), and run distance (cm) (GVO 2 = 43.5% and GVP = 33.4%), after 4 weeks of aerobic training (time effect, P < 0.05); there were no differences between the groups. Conclusions: V peak_K , as well as vVO 2max , can be adopted as an alternative test to determine the performance and correct prescription of systemized aerobic protocol training to mice.

  14. Regional Variation in Neonatal Intensive Care Admissions and the Relationship to Bed Supply.

    Science.gov (United States)

    Harrison, Wade N; Wasserman, Jared R; Goodman, David C

    2018-01-01

    To characterize geographic variation in neonatal intensive care unit (NICU) admission rates across the entire birth cohort and evaluate the relationship between regional bed supply and NICU admission rates. This was a population-based, cross-sectional study. 2013 US birth certificate and 2012 American Hospital Association data were used to assign newborns and NICU beds to neonatal intensive care regions. Descriptive statistics of admission rates were calculated across neonatal intensive care regions. Multilevel logistic regression was used to examine the relationship between bed supply and individual odds of admission, with adjustment for maternal and newborn characteristics. Among 3 304 364 study newborns, the NICU admission rate was 7.2 per 100 births and varied across regions for all birth weight categories. IQRs in admission rates were 84.5-93.2 per 100 births for 500-1499 g, 35.3-46.1 for 1500-2499 g, and 3.5-5.5 for ≥2500 g. Adjusted odds of admission for newborns of very low birth weight were unrelated to regional bed supply; however, newborns ≥2500 g in regions with the highest NICU bed supply were significantly more likely to be admitted to a NICU than those in regions with the lowest (aOR 1.20 [1.03-1.40]). There is persistent underuse of NICU care for newborns of very low birth weight that is not associated with regional bed supply. Among larger newborns, we find evidence of supply-sensitive care, raising concerns about the potential overuse of expensive and unnecessary care. Rather than improving access to needed care, NICU expansion may instead further deregionalize neonatal care, exacerbating underuse. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex

    Directory of Open Access Journals (Sweden)

    Shan Juan Xie

    2015-07-01

    Full Text Available Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc. vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs. In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV normalization method using guided filter based single scale retinex (GFSSR is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.

  16. Automatic fitting of Gaussian peaks using abductive machine learning

    Science.gov (United States)

    Abdel-Aal, R. E.

    1998-02-01

    Analytical techniques have been used for many years for fitting Gaussian peaks in nuclear spectroscopy. However, the complexity of the approach warrants looking for machine-learning alternatives where intensive computations are required only once (during training), while actual analysis on individual spectra is greatly simplified and quickened. This should allow the use of simple portable systems for fast and automated analysis of large numbers of spectra, particularly in situations where accuracy may be traded for speed and simplicity. This paper proposes the use of abductive networks machine learning for this purpose. The Abductory Induction Mechanism (AIM) tool was used to build models for analyzing both single and double Gaussian peaks in the presence of noise depicting statistical uncertainties in collected spectra. AIM networks were synthesized by training on 1000 representative simulated spectra and evaluated on 500 new spectra. A classifier network determines the multiplicity of single/double peaks with an accuracy of 5.8%. With statistical uncertainties corresponding to a peak count of 100, average percentage absolute errors for the height, position, and width of single peaks are 4.9, 2.9, and 4.2%, respectively. For double peaks, these average errors are within 7.0, 3.1, and 5.9%, respectively. Models have been developed which account for the effect of a linear background on a single peak. Performance is compared with a neural network application and with an analytical curve-fitting routine, and the new technique is applied to actual data of an alpha spectrum.

  17. Automatic fitting of Gaussian peaks using abductive machine learning

    International Nuclear Information System (INIS)

    Abdel-Aal, R.E.

    1998-01-01

    Analytical techniques have been used for many years for fitting Gaussian peaks in nuclear spectroscopy. However, the complexity of the approach warrants looking for machine-learning alternatives where intensive computations are required only once (during training), while actual analysis on individual spectra is greatly simplified and quickened. This should allow the use of simple portable systems for fast and automated analysis of large numbers of spectra, particularly in situations where accuracy may be traded for speed and simplicity. This paper proposes the use of abductive networks machine learning for this purpose. The Abductory Induction Mechanism (AIM) tool was used to build models for analyzing both single and double Gaussian peaks in the presence of noise depicting statistical uncertainties in collected spectra. AIM networks were synthesized by training on 1,000 representative simulated spectra and evaluated on 500 new spectra. A classifier network determines the multiplicity of single/double peaks with an accuracy of 98%. With statistical uncertainties corresponding to a peak count of 100, average percentage absolute errors for the height, position, and width of single peaks are 4.9, 2.9, and 4.2%, respectively. For double peaks, these average errors are within 7.0, 3.1, and 5.9%, respectively. Models have been developed which account for the effect of a linear background on a single peak. Performance is compared with a neural network application and with an analytical curve-fitting routine, and the new technique is applied to actual data of an alpha spectrum

  18. The spatial resolution of epidemic peaks.

    Directory of Open Access Journals (Sweden)

    Harriet L Mills

    2014-04-01

    Full Text Available The emergence of novel respiratory pathogens can challenge the capacity of key health care resources, such as intensive care units, that are constrained to serve only specific geographical populations. An ability to predict the magnitude and timing of peak incidence at the scale of a single large population would help to accurately assess the value of interventions designed to reduce that peak. However, current disease-dynamic theory does not provide a clear understanding of the relationship between: epidemic trajectories at the scale of interest (e.g. city; population mobility; and higher resolution spatial effects (e.g. transmission within small neighbourhoods. Here, we used a spatially-explicit stochastic meta-population model of arbitrary spatial resolution to determine the effect of resolution on model-derived epidemic trajectories. We simulated an influenza-like pathogen spreading across theoretical and actual population densities and varied our assumptions about mobility using Latin-Hypercube sampling. Even though, by design, cumulative attack rates were the same for all resolutions and mobilities, peak incidences were different. Clear thresholds existed for all tested populations, such that models with resolutions lower than the threshold substantially overestimated population-wide peak incidence. The effect of resolution was most important in populations which were of lower density and lower mobility. With the expectation of accurate spatial incidence datasets in the near future, our objective was to provide a framework for how to use these data correctly in a spatial meta-population model. Our results suggest that there is a fundamental spatial resolution for any pathogen-population pair. If underlying interactions between pathogens and spatially heterogeneous populations are represented at this resolution or higher, accurate predictions of peak incidence for city-scale epidemics are feasible.

  19. Low- and high-frequency spectral behavior of cosmic-ray intensity for the period 1953–1996

    Directory of Open Access Journals (Sweden)

    H. Mavromichalaki

    2003-08-01

    Full Text Available A study of the cosmic-ray intensity power spectrum using the Climax Neutron Monitor data in the frequency range from 10-9 Hz to 10-7 Hz (which corresponds to periodicities from 11 years to a few months during the period 1953–1996, was carried out by means of the successive approximations method of analysis and was compared against the power spectrum and the maximum entropy methods. The contributions of the time evolution of several peaks to the global one were obtained. Except for the well-known 11-year and the 1-year variations, peaks at 7.7, 5.5, 2 and 1.7 years are found. Several peaks with periods less than 10 months have appeared in our analysis, while the occurrence of 5.1 months is obtained in all the examined solar cycles with a strong signature in cycle 21. Transitions of these quasi-periodicities are seen in power spectra plots. Some of them can be attributed to the modulation of the cosmic ray intensity by solar activity. Others are sporadic and have been previously attributed to the interplanetary magnetic field. The results obtained support once again the argument regarding the difference in the solar activity between odd and even solar cycles.Key words. Interplanetary physics (Cosmic rays, Interplanetary magnetic fields

  20. Fast geomagnetic Field Intensity Variations between 1400 and 400 BCE: New Archaeointensity Data from Germany

    Science.gov (United States)

    Hervé, G.; Schnepp, E.; Metzler-Nebelsick, C.; Lhuillier, F.; Gilder, S.; Genevey, A.; Fassbinder, J.; Gallet, Y.

    2017-12-01

    Thirty-five mean archaeointensity data were obtained on ceramic sherds dated between 1400 and 400 BCE from sites located near Munich, Germany. The 453 sherds were collected from 52 graves, pits and wells dated by archaeological correlation, radiocarbon and/or dendrochronology. Rock magnetic analyses indicate that the remanent magnetization was mainly carried by magnetite. Data from Thellier-Thellier experiments were corrected for anisotropy and cooling rate effects. Triaxe and multispecimen (MSP-DSC) protocols were also measured on a subset of specimens. Around 60% of the samples provide reliable results when using stringent criteria selection. The 35 average archaeointensity values based on 154 pots are consistent with previous data and triple the Western Europe database between 1400 and 400 BCE. A secular variation curve for central-western Europe, built using a Bayesian approach, shows a double oscillation in geomagnetic field strength with intensity maxima of 70 μT around 1000-900 BCE and another up to 90 μT around 600-500 BCE. The maximum rate of variation was 0.25 μT/yr circa 700 BCE. The secular variation trend in Western Europe is similar to that observed in the Middle East and the Caucasus except that we find no evidence for hyper-rapid field variations (i.e. geomagnetic spikes). Virtual Axial Dipole Moments from Western Europe, the Middle East and central Asia differ by more than 20 ZA·m2 prior to 600 BCE, which signifies a departure from an axial dipole field especially between 1000 and 600 BCE. Our observations suggest that the regional Levantine Iron Age anomaly has been accompanied by an increase of the axial dipole moment together with a tilt of the dipole.

  1. Muscle injury after low-intensity downhill running reduces running economy.

    Science.gov (United States)

    Baumann, Cory W; Green, Michael S; Doyle, J Andrew; Rupp, Jeffrey C; Ingalls, Christopher P; Corona, Benjamin T

    2014-05-01

    Contraction-induced muscle injury may reduce running economy (RE) by altering motor unit recruitment, lowering contraction economy, and disturbing running mechanics, any of which may have a deleterious effect on endurance performance. The purpose of this study was to determine if RE is reduced 2 days after performing injurious, low-intensity exercise in 11 healthy active men (27.5 ± 5.7 years; 50.05 ± 1.67 VO2peak). Running economy was determined at treadmill speeds eliciting 65 and 75% of the individual's peak rate of oxygen uptake (VO2peak) 1 day before and 2 days after injury induction. Lower extremity muscle injury was induced with a 30-minute downhill treadmill run (6 × 5 minutes runs, 2 minutes rest, -12% grade, and 12.9 km·h(-1)) that elicited 55% VO2peak. Maximal quadriceps isometric torque was reduced immediately and 2 days after the downhill run by 18 and 10%, and a moderate degree of muscle soreness was present. Two days after the injury, steady-state VO2 and metabolic work (VO2 L·km(-1)) were significantly greater (4-6%) during the 65% VO2peak run. Additionally, postinjury VCO2, VE and rating of perceived exertion were greater at 65% but not at 75% VO2peak, whereas whole blood-lactate concentrations did not change pre-injury to postinjury at either intensity. In conclusion, low-intensity downhill running reduces RE at 65% but not 75% VO2peak. The results of this study and other studies indicate the magnitude to which RE is altered after downhill running is dependent on the severity of the injury and intensity of the RE test.

  2. Seasonal variations in house dust mite influence the circadian peak expiratory flow amplitude

    NARCIS (Netherlands)

    Postma, DS; vanderHeide, S; deReus, DM; Koeter, GH; vanAalderen, WMC; Meijer, G.

    1996-01-01

    The aim of the study was to investigate whether seasonal differences in house dust mite (HDM) allergen exposure influence the circadian peak expiratory flow (PEF) amplitude in asthmatic children. Asthmatic children (n = 25) with a solitary allergy to HDM were studied in spring and in autumn. All

  3. Does team lifting increase the variability in peak lumbar compression in ironworkers?

    Science.gov (United States)

    Faber, Gert; Visser, Steven; van der Molen, Henk F; Kuijer, P Paul F M; Hoozemans, Marco J M; Van Dieën, Jaap H; Frings-Dresen, Monique H W

    2012-01-01

    Ironworkers frequently perform heavy lifting tasks in teams of two or four workers. Team lifting could potentially lead to a higher variation in peak lumbar compression forces than lifts performed by one worker, resulting in higher maximal peak lumbar compression forces. This study compared single-worker lifts (25-kg, iron bar) to two-worker lifts (50-kg, two iron bars) and to four-worker lifts (100-kg, iron lattice). Inverse dynamics was used to calculate peak lumbar compression forces. To assess the variability in peak lumbar loading, all three lifting tasks were performed six times. Results showed that the variability in peak lumbar loading was somewhat higher in the team lifts compared to the single-worker lifts. However, despite this increased variability, team lifts did not result in larger maximum peak lumbar compression forces. Therefore, it was concluded that, from a biomechanical point of view, team lifting does not result in an additional risk for low back complaints in ironworkers.

  4. Where does HIT fit? An examination of the affective response to high-intensity intervals in comparison to continuous moderate- and continuous vigorous-intensity exercise in the exercise intensity-affect continuum.

    Directory of Open Access Journals (Sweden)

    Mary E Jung

    Full Text Available Affect experienced during an exercise session is purported to predict future exercise behaviour. Compared to continuous moderate-intensity exercise (CMI, the affective response to continuous vigorous-intensity exercise (CVI has consistently been shown to be more aversive. The affective response, and overall tolerability to high-intensity interval training (HIT, is less studied. To date, there has yet to be a comparison between HIT, CVI, and CMI. The purpose of this study was to compare the tolerability and affective responses during HIT to CVI and CMI. This study utilized a repeated measures, randomized, counter-balanced design. Forty-four participants visited the laboratory on four occasions. Baseline fitness testing was conducted to establish peak power output in Watts (W peak. Three subsequent visits involved a single bout of a HIT, corresponding to 1-minute at ∼ 100% W peak and 1-minute at ∼ 20% W peak for 20 minutes, b CMI, corresponding to ∼ 40% W peak for 40 minutes, and c CVI, corresponding to ∼ 80% W peak for 20 minutes. The order of the sessions was randomized. Affective responses were measured before, during and after each session. Task self-efficacy, intentions, enjoyment and preference were measured after sessions. Participants reported greater enjoyment of HIT as compared to CMI and CVI, with over 50% of participants reporting a preference to engage in HIT as opposed to either CMI or CVI. HIT was considered more pleasurable than CVI after exercise, but less pleasurable than CMI at these times. Despite this participants reported being just as confident to engage in HIT as they were CMI, but less confident to engage in CVI. This study highlights the utility of HIT in inactive individuals, and suggests that it may be a viable alternative to traditionally prescribed continuous modalities of exercise for promoting self-efficacy and enjoyment of exercise.

  5. Where does HIT fit? An examination of the affective response to high-intensity intervals in comparison to continuous moderate- and continuous vigorous-intensity exercise in the exercise intensity-affect continuum.

    Science.gov (United States)

    Jung, Mary E; Bourne, Jessica E; Little, Jonathan P

    2014-01-01

    Affect experienced during an exercise session is purported to predict future exercise behaviour. Compared to continuous moderate-intensity exercise (CMI), the affective response to continuous vigorous-intensity exercise (CVI) has consistently been shown to be more aversive. The affective response, and overall tolerability to high-intensity interval training (HIT), is less studied. To date, there has yet to be a comparison between HIT, CVI, and CMI. The purpose of this study was to compare the tolerability and affective responses during HIT to CVI and CMI. This study utilized a repeated measures, randomized, counter-balanced design. Forty-four participants visited the laboratory on four occasions. Baseline fitness testing was conducted to establish peak power output in Watts (W peak). Three subsequent visits involved a single bout of a) HIT, corresponding to 1-minute at ∼ 100% W peak and 1-minute at ∼ 20% W peak for 20 minutes, b) CMI, corresponding to ∼ 40% W peak for 40 minutes, and c) CVI, corresponding to ∼ 80% W peak for 20 minutes. The order of the sessions was randomized. Affective responses were measured before, during and after each session. Task self-efficacy, intentions, enjoyment and preference were measured after sessions. Participants reported greater enjoyment of HIT as compared to CMI and CVI, with over 50% of participants reporting a preference to engage in HIT as opposed to either CMI or CVI. HIT was considered more pleasurable than CVI after exercise, but less pleasurable than CMI at these times. Despite this participants reported being just as confident to engage in HIT as they were CMI, but less confident to engage in CVI. This study highlights the utility of HIT in inactive individuals, and suggests that it may be a viable alternative to traditionally prescribed continuous modalities of exercise for promoting self-efficacy and enjoyment of exercise.

  6. Photoneutron intensity variation with field size around radiotherapy linear accelerator 18-MeV X-ray beam

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ghamdi, H.; Fazal-ur-Rehman [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Jarallah, M.I. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: mibrahim@kfupm.edu.sa; Maalej, N. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2008-08-15

    In X-ray radiotherapy accelerators, neutrons are produced mainly by ({gamma},n) reaction when high energy X-rays interact with high Z materials of the linear accelerator head. These materials include the lead (Pb) used as shielding in the collimator, tungsten (W) target used for the production of X-rays and iron (Fe) in the accelerator head. These unwanted neutrons contaminate the therapeutic beam and contribute to the patient dose during the treatment of a cancer patient. Knowing the neutron distribution around the radiotherapy accelerator is therefore desired. CR-39 nuclear track detectors (NTDs) were used to study the variation of fast and thermal neutron relative intensities around an 18 MeV linear accelerator X-ray beam with the field sizes of 0, 10x10, 20x20, 30x30 and 40x40cm{sup 2}. For fast neutron detection, bare NTDs were used. For thermal neutron detection, NTDs were covered with lithium tetra borate (Li{sub 2}B{sub 4}O{sub 7}) converters. The NTDs were placed at different locations in the direction perpendicular to the treatment couch (transversal) and in the direction parallel to the treatment couch (longitudinal) with respect to the isocenter of the accelerator. The fast neutron relative intensity is symmetrical about the beam axis and exhibits an exponential-like drop with distance from the isocenter of the accelerator for all the field sizes. At the primary beam (isocenter), the relative fast neutron intensity is highest for 40x40cm{sup 2} field size and decreases linearly with the decrease in the field size. However, fast neutron intensities do not change significantly with beam size for the measurements outside the primary beam. The fast neutron intensity in the longitudinal direction outside the primary beam decreases linearly with the field size. The thermal neutron intensity, at any location, was found to be almost independent of the field size.

  7. Prediction of galactic cosmic ray intensity variation for a few (up to 10-12 years ahead on the basis of convection-diffusion and drift model

    Directory of Open Access Journals (Sweden)

    L. I. Dorman

    2005-11-01

    Full Text Available We determine the dimension of the Heliosphere (modulation region, radial diffusion coefficient and other parameters of convection-diffusion and drift mechanisms of cosmic ray (CR long-term variation, depending on particle energy, the level of solar activity (SA and general solar magnetic field. This important information we obtain on the basis of CR and SA data in the past, taking into account the theory of convection-diffusion and drift global modulation of galactic CR in the Heliosphere. By using these results and the predictions which are regularly published elsewhere of expected SA variation in the near future and prediction of next future SA cycle, we may make a prediction of the expected in the near future long-term cosmic ray intensity variation. We show that by this method we may make a prediction of the expected in the near future (up to 10-12 years, and may be more, in dependence for what period can be made definite prediction of SA galactic cosmic ray intensity variation in the interplanetary space on different distances from the Sun, in the Earth's magnetosphere, and in the atmosphere at different altitudes and latitudes.

  8. [A peak recognition algorithm designed for chromatographic peaks of transformer oil].

    Science.gov (United States)

    Ou, Linjun; Cao, Jian

    2014-09-01

    In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.

  9. Variations in peak nasal inspiratory flow among healthy students after using saline solutions.

    Science.gov (United States)

    Olbrich Neto, Jaime; Olbrich, Sandra Regina Leite Rosa; Mori, Natália Leite Rosa; Oliveira, Ana Elisa de; Corrente, José Eduardo

    2016-01-01

    Nasal hygiene with saline solutions has been shown to relieve congestion, reduce the thickening of the mucus and keep nasal cavity clean and moist. Evaluating whether saline solutions improve nasal inspiratory flow among healthy children. Students between 8 and 11 years of age underwent 6 procedures with saline solutions at different concentrations. The peak nasal inspiratory flow was measured before and 30 min after each procedure. Statistical analysis was performed by means of t test, analysis of variance, and Tukey's test, considering p<0.05. We evaluated 124 children at all stages. There were differences on the way a same concentration was used. There was no difference between 0.9% saline solution and 3% saline solution by using a syringe. The 3% saline solution had higher averages of peak nasal inspiratory flow, but it was not significantly higher than the 0.9% saline solution. It is important to offer various options to patients. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  10. Peaking of world oil production: Impacts, mitigation, & risk management

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, R.L. (SAIC); Bezdek, Roger (MISI); Wendling, Robert (MISI)

    2005-02-01

    The peaking of world oil production presents the U.S. and the world with an unprecedented risk management problem. As peaking is approached, liquid fuel prices and price volatility will increase dramatically, and, without timely mitigation, the economic, social, and political costs will be unprecedented. Viable mitigation options exist on both the supply and demand sides, but to have substantial impact, they must be initiated more than a decade in advance of peaking.... The purpose of this analysis was to identify the critical issues surrounding the occurrence and mitigation of world oil production peaking. We simplified many of the complexities in an effort to provide a transparent analysis. Nevertheless, our study is neither simple nor brief. We recognize that when oil prices escalate dramatically, there will be demand and economic impacts that will alter our simplified assumptions. Consideration of those feedbacks will be a daunting task but one that should be undertaken. Our aim in this study is to-- • Summarize the difficulties of oil production forecasting; • Identify the fundamentals that show why world oil production peaking is such a unique challenge; • Show why mitigation will take a decade or more of intense effort; • Examine the potential economic effects of oil peaking; • Describe what might be accomplished under three example mitigation scenarios. • Stimulate serious discussion of the problem, suggest more definitive studies, and engender interest in timely action to mitigate its impacts.

  11. Applicability of Pulse Pressure Variation during Unstable Hemodynamic Events in the Intensive Care Unit: A Five-Day Prospective Multicenter Study

    Directory of Open Access Journals (Sweden)

    Bertrand Delannoy

    2016-01-01

    Full Text Available Pulse pressure variation can predict fluid responsiveness in strict applicability conditions. The purpose of this study was to describe the clinical applicability of pulse pressure variation during episodes of patient hemodynamic instability in the intensive care unit. We conducted a five-day, seven-center prospective study that included patients presenting with an unstable hemodynamic event. The six predefined inclusion criteria for pulse pressure variation applicability were as follows: mechanical ventilation, tidal volume >7 mL/kg, sinus rhythm, no spontaneous breath, heart rate/respiratory rate ratio >3.6, absence of right ventricular dysfunction, or severe valvulopathy. Seventy-three patients presented at least one unstable hemodynamic event, with a total of 163 unstable hemodynamic events. The six predefined criteria for the applicability of pulse pressure variation were completely present in only 7% of these. This data indicates that PPV should only be used alongside a strong understanding of the relevant physiology and applicability criteria. Although these exclusion criteria appear to be profound, they likely represent an absolute contraindication of use for only a minority of critical care patients.

  12. Tidal and near-inertial peak variations around the diurnal critical latitude

    Science.gov (United States)

    van Haren, Hans

    2005-12-01

    Spectra from historic long-term open-ocean moored current meter data between latitudes 0° shift of the peak frequency to 0.97 +/- 0.01f, or a poleward spreading of enhanced energy. This contrasts with more common blue-shift. The enhancement may be the result of sub-harmonic instability, as supported by sparse significant bicoherence at half-D2, although i) systematic enhancement of diurnal tidal frequencies, notably M1, was not observed, ii) the latitudes of low D2-energy and high f-energy do not coincide. This may be due to a mix of coupled and independent waves, whilst the poleward trapping of sub-f energy suggests non-traditional effects.

  13. Solar UV radiation variations and their stratospheric and climatic effects

    Science.gov (United States)

    Donnelly, R. F.; Heath, D. F.

    1985-01-01

    Nimbus-7 SBUV measurements of the short-term solar UV variations caused by solar rotation and active-region evolution have determined the amplitude and wavelength dependence for the active-region component of solar UV variations. Intermediate-term variations lasting several months are associated with rounds of major new active regions. The UV flux stays near the peak value during the current solar cycle variation for more than two years and peaks about two years later than the sunspot number. Nimbus-7 measurements have observed the concurrent stratospheric ozone variations caused by solar UV variations. There is now no doubt that solar UV variations are an important cause of short- and long-term stratospheric variations, but the strength of the coupling to the troposphere and to climate has not yet been proven.

  14. Patient-specific AAA wall stress analysis: 99-percentile versus peak stress

    NARCIS (Netherlands)

    Speelman, L.; Bosboom, E.M.H.; Schurink, G.W.H.; Hellenthal, F.A.M.V.I.; Buth, J.; Breeuwer, M.; Jacobs, M.J.; Vosse, van de F.N.

    2008-01-01

    Objective Biomechanically, rupture of an Abdominal Aortic Aneurysm (AAA) occurs when the stress acting on the wall due to the blood pressure, exceeds the strength of the wall. Peak wall stress estimations, based on CT reconstruction, may be prone to observer variation. This study focuses on the

  15. Determination of the diagnostic x-ray tube practical peak voltage (PPV) from average or average peak voltage measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hourdakis, C J, E-mail: khour@gaec.gr [Ionizing Radiation Calibration Laboratory-Greek Atomic Energy Commission, PO Box 60092, 15310 Agia Paraskevi, Athens, Attiki (Greece)

    2011-04-07

    The practical peak voltage (PPV) has been adopted as the reference measuring quantity for the x-ray tube voltage. However, the majority of commercial kV-meter models measure the average peak, U-bar{sub P}, the average, U-bar, the effective, U{sub eff} or the maximum peak, U{sub P} tube voltage. This work proposed a method for determination of the PPV from measurements with a kV-meter that measures the average U-bar or the average peak, U-bar{sub p} voltage. The kV-meter reading can be converted to the PPV by applying appropriate calibration coefficients and conversion factors. The average peak k{sub PPV,kVp} and the average k{sub PPV,Uav} conversion factors were calculated from virtual voltage waveforms for conventional diagnostic radiology (50-150 kV) and mammography (22-35 kV) tube voltages and for voltage ripples from 0% to 100%. Regression equation and coefficients provide the appropriate conversion factors at any given tube voltage and ripple. The influence of voltage waveform irregularities, like 'spikes' and pulse amplitude variations, on the conversion factors was investigated and discussed. The proposed method and the conversion factors were tested using six commercial kV-meters at several x-ray units. The deviations between the reference and the calculated - according to the proposed method - PPV values were less than 2%. Practical aspects on the voltage ripple measurement were addressed and discussed. The proposed method provides a rigorous base to determine the PPV with kV-meters from U-bar{sub p} and U-bar measurement. Users can benefit, since all kV-meters, irrespective of their measuring quantity, can be used to determine the PPV, complying with the IEC standard requirements.

  16. Importance of selecting archaeomagnetic data for geomagnetic modelling: example of the new Western Europe directional and intensity secular variation curves from 1500 BC to 200 AD

    Science.gov (United States)

    Herve, Gwenael; Chauvin, Annick; Lanos, Philippe

    2014-05-01

    At the regional scale, the dispersion between archaeomagnetic data and especially archaeointensities suggests that some of them may be biased. As a consequence, it appears necessary to perform a selection of available data before to compute mean regional secular variation curves or geomagnetic models. However the definition of suitable selection criteria is not obvious and we need to know how to manage "old" data acquired during the 60-70s. The Western Europe directional and intensity data set from 1500 BC to 200 AD allows to discuss these issues. It has recently been enhanced by 39 new archaeodirections and 23 new archaeointensities (Hervé et al., 2013a and 2013b data sets and 5 unpublished data). First, the whole Western Europe data set was selected but the strong dispersion restricted the accuracy and the reliability of the new Western Europe secular variation curves at Paris. The causes of the dispersion appear different between archaeodirections and archaeointensities. In the directional data set, the main problem comes from some age errors in the oldest published data. Since their publication their archaeological dating may have changed of 50 years or more. For intensity data that were acquired much more recently, the dispersion mainly results from the use of unreliable archaeointensity protocols. We propose a weighting approach based on the number of specimens and the use of pTRM-checks, anisotropy and cooling rate corrections. Only 63% of available archaeodirections and 32% of archaeointensities were used to build the new Western Europe secular variation curves from 1500 BC to 200 AD. These curves reveal that selecting the reference data avoids wrong estimations of the shape of the secular variation curves, the secular variation rate, the dating of archaeomagnetic jerks... Finally, it is worth pointing out that current geomagnetic global models take into account almost all the data that we decided to reject. It could partly explain why their predictions at

  17. Solar Cycle variations in Earth's open flux content measured by the SuperDARN radar network

    Science.gov (United States)

    Imber, S. M.; Milan, S. E.; Lester, M.

    2013-09-01

    We present a long term study, from 1996 - 2012, of the latitude of the Heppner-Maynard Boundary (HMB) determined using the northern hemisphere SuperDARN radars. The HMB represents the equatorward extent of ionospheric convection and is here used as a proxy for the amount of open flux in the polar cap. The mean HMB latitude (measured at midnight) is found to be at 64 degrees during the entire period, with secondary peaks at lower latitudes during the solar maximum of 2003, and at higher latitudes during the recent extreme solar minimum of 2008-2011. We associate these large scale statistical variations in open flux content with solar cycle variations in the solar wind parameters leading to changes in the intensity of the coupling between the solar wind and the magnetosphere.

  18. The velocity of light intensity increase modulates the photoprotective response in coastal diatoms.

    Directory of Open Access Journals (Sweden)

    Vasco Giovagnetti

    Full Text Available In aquatic ecosystems, the superimposition of mixing events to the light diel cycle exposes phytoplankton to changes in the velocity of light intensity increase, from diurnal variations to faster mixing-related ones. This is particularly true in coastal waters, where diatoms are dominant. This study aims to investigate if coastal diatoms differently activate the photoprotective responses, xanthophyll cycle (XC and non-photochemical fluorescence quenching (NPQ, to cope with predictable light diel cycle and unpredictable mixing-related light variations. We compared the effect of two fast light intensity increases (simulating mixing events with that of a slower increase (corresponding to the light diel cycle on the modulation of XC and NPQ in the planktonic coastal diatom Pseudo-nitzschia multistriata. During each light treatment, the photon flux density (PFD progressively increased from darkness to five peaks, ranging from 100 to 650 µmol photons m-2 s-1. Our results show that the diel cycle-related PFD increase strongly activates XC through the enhancement of the carotenoid biosynthesis and induces a moderate and gradual NPQ formation over the light gradient. In contrast, during mixing-related PFD increases, XC is less activated, while higher NPQ rapidly develops at moderate PFD. We observe that together with the light intensity and its increase velocity, the saturation light for photosynthesis (Ek is a key parameter in modulating photoprotection. We propose that the capacity to adequately regulate and actuate alternative photoprotective 'safety valves' in response to changing velocity of light intensity increase further enhances the photophysiological flexibility of diatoms. This might be an evolutionary outcome of diatom adaptation to turbulent marine ecosystems characterized by unpredictable mixing-related light changes over the light diel cycle.

  19. A semi-automatic method for peak and valley detection in free-breathing respiratory waveforms

    International Nuclear Information System (INIS)

    Lu Wei; Nystrom, Michelle M.; Parikh, Parag J.; Fooshee, David R.; Hubenschmidt, James P.; Bradley, Jeffrey D.; Low, Daniel A.

    2006-01-01

    The existing commercial software often inadequately determines respiratory peaks for patients in respiration correlated computed tomography. A semi-automatic method was developed for peak and valley detection in free-breathing respiratory waveforms. First the waveform is separated into breath cycles by identifying intercepts of a moving average curve with the inspiration and expiration branches of the waveform. Peaks and valleys were then defined, respectively, as the maximum and minimum between pairs of alternating inspiration and expiration intercepts. Finally, automatic corrections and manual user interventions were employed. On average for each of the 20 patients, 99% of 307 peaks and valleys were automatically detected in 2.8 s. This method was robust for bellows waveforms with large variations

  20. PEAK SHIFTS PRODUCED BY CORRELATED RESPONSE TO SELECTION.

    Science.gov (United States)

    Price, Trevor; Turelli, Michael; Slatkin, Montgomery

    1993-02-01

    Traits may evolve both as a consequence of direct selection and also as a correlated response to selection on other traits. While correlated response may be important for both the production of evolutionary novelty and in the build-up of complex characters, its potential role in peak shifts has been neglected empirically and theoretically. We use a quantitative genetic model to investigate the conditions under which a character, Y, which has two alternative optima, can be dragged from one optimum to the other as a correlated response to selection on a second character, X. High genetic correlations between the two characters make the transition, or peak shift, easier, as does weak selection tending to restore Y to the optimum from which it is being dragged. When selection on Y is very weak, the conditions for a peak shift depend only on the location of the new optimum for X and are independent of the strength of selection moving it there. Thus, if the "adaptive valley" for Y is very shallow, little reduction in mean fitness is needed to produce a shift. If the selection acts strongly to keep Y at its current optimum, very intense directional selection on X, associated with a dramatic drop in mean fitness, is required for a peak shift. When strong selection is required, the conditions for peak shifts driven by correlated response might occur rarely, but still with sufficient frequency on a geological timescale to be evolutionarily important. © 1993 The Society for the Study of Evolution.

  1. Seasonal variation in family member perceptions of physician competence in the intensive care unit: findings from one academic medical center.

    Science.gov (United States)

    Stevens, Jennifer P; Kachniarz, Bart; O'Reilly, Kristin; Howell, Michael D

    2015-04-01

    Researchers have found mixed results about the risk to patient safety in July, when newly minted physicians enter U.S. hospitals to begin their clinical training, the so-called "July effect." However, patient and family satisfaction and perception of physician competence during summer months remain unknown. The authors conducted a retrospective observational cohort study of 815 family members of adult intensive care unit (ICU) patients who completed the Family Satisfaction with Care in the Intensive Care Unit instrument from eight ICUs at Beth Israel Deaconess Medical Center, Boston, Massachusetts, between April 2008 and June 2011. The association of ICU care in the summer months (July-September) versus other seasons and family perception of physician competence was examined in univariable and multivariable analyses. A greater proportion of family members described physicians as competent in summer months as compared with winter months (odds ratio [OR] 1.9; 95% confidence interval [CI] 1.2-3.0; P = .003). After adjustment for patient and proxy demographics, severity of illness, comorbidities, and features of the admission in a multivariable model, seasonal variation of family perception of physician competence persisted (summer versus winter, OR of judging physicians competent 2.4; 95% CI 1.3-4.4; P = .004). Seasonal variation exists in family perception of physician competence in the ICU, but opposite to the "July effect." The reasons for this variation are not well understood. Further research is necessary to explore the role of senior provider involvement, trainee factors, system factors such as handoffs, or other possible contributors.

  2. Short-term high-intensity interval and moderate-intensity continuous training reduce leukocyte TLR4 in inactive adults at elevated risk of type 2 diabetes.

    Science.gov (United States)

    Robinson, Emily; Durrer, Cody; Simtchouk, Svetlana; Jung, Mary E; Bourne, Jessica E; Voth, Elizabeth; Little, Jonathan P

    2015-09-01

    Exercise can have anti-inflammatory effects in obesity, but the optimal type and intensity of exercise are not clear. This study compared short-term high-intensity interval training (HIIT) with moderate-intensity continuous training (MICT) in terms of improvement in cardiorespiratory fitness, markers of inflammation, and glucose control in previously inactive adults at elevated risk of developing type 2 diabetes. Thirty-nine inactive, overweight/obese adults (32 women) were randomly assigned to 10 sessions over 2 wk of progressive HIIT (n = 20, four to ten 1-min sessions at ∼90% peak heart rate, 1-min rest periods) or MICT (n = 19, 20-50 min at ∼65% peak heart rate). Before and 3 days after training, participants performed a peak O2 uptake test, and fasting blood samples were obtained. Both HIIT (1.8 ± 0.4 vs. 1.9 ± 0.4 l/min, pre vs. post) and MICT (1.8 ± 0.5 vs. 1.9 ± 0.5 l/min, pre vs. post) improved peak O2 uptake (P fasting plasma glucose (P fasting glucose. Copyright © 2015 the American Physiological Society.

  3. The phase differences of the interdecadal variabilities of tropical cyclone activity in the peak and late seasons over the western North Pacific

    Science.gov (United States)

    Fan, Tingting; Xu, Shibin; Huang, Fei; Zhao, Jinping

    2018-04-01

    This study compares the interdecadal variations in tropical cyclone (TC) activities over the western North Pacific (WNP) basin during the peak season (July-September) and late season (October-December) of 1955-2014 and explores the possible physical mechanisms behind the variations. Both the peak- and late-season tropical storm (TS) days show distinct interdecadal variations, while the late-season TS days lead the peak-season TS days by approximately 4 years on an interdecadal time scale. The late-season TC activity is related to the east-west sea surface temperature (SST) gradient across the equatorial Pacific. The westerly winds induced by the SST gradient can reduce the vertical wind shear and increase the low-level vorticity, which favors TC genesis over the TC genesis region. The peak-season TC activity appears to relate to the SST gradient between the Indian Ocean and the Central Pacific. The westerly wind induced by the SST gradient can reduce the vertical wind shear and increase the mid-level relative humidity, thereby enhancing the TC activity. The full picture of the interdecadal variation in the WNP TC activity during the peak and late seasons revealed in this study provides a new perspective on the seasonal TC forecasts and future projections.

  4. A new record peak luminosity for the LHC

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Two weeks of dedicated machine development paid off last weekend when the LHC ran for physics with three nominal intensity (∼1011 protons) bunches in each beam.   This brought a new record peak luminosity of around 8×1029 cm-2 s-1, and allowed the LHC to double the integrated luminosity delivered to the experiments since 30 March from 16 to 32 inverse nanobarns over the weekend. After a few more fills in this configuration, the number of bunches will be raised to six per beam, which will in turn allow the peak luminosity to break the 1030 cm-2 s-1 barrier for the first time, well on the way to achieving the 2010 objective of 1032 cm-2 s-1. This peak luminosity goal requires 800 nominal bunches per beam squeezed to a beta of 3.5 metres. The plan for 2011 is to run the LHC in this configuration over about 10 months, thus achieving the objective of recording one inverse femtobarn of data in total. The machine development period also allowed the TOTEM detectors to be set up with 45...

  5. Forecasting monthly peak demand of electricity in India—A critique

    International Nuclear Information System (INIS)

    Rallapalli, Srinivasa Rao; Ghosh, Sajal

    2012-01-01

    The nature of electricity differs from that of other commodities since electricity is a non-storable good and there have been significant seasonal and diurnal variations of demand. Under such condition, precise forecasting of demand for electricity should be an integral part of the planning process as this enables the policy makers to provide directions on cost-effective investment and on scheduling the operation of the existing and new power plants so that the supply of electricity can be made adequate enough to meet the future demand and its variations. Official load forecasting in India done by Central Electricity Authority (CEA) is often criticized for being overestimated due to inferior techniques used for forecasting. This paper tries to evaluate monthly peak demand forecasting performance predicted by CEA using trend method and compare it with those predicted by Multiplicative Seasonal Autoregressive Integrated Moving Average (MSARIMA) model. It has been found that MSARIMA model outperforms CEA forecasts both in-sample static and out-of-sample dynamic forecast horizons in all five regional grids in India. For better load management and grid discipline, this study suggests employing sophisticated techniques like MSARIMA for peak load forecasting in India. - Highlights: ► This paper evaluates monthly peak demand forecasting performance by CEA. ► Compares CEA forecasts it with those predicted by MSARIMA model. ► MSARIMA model outperforms CEA forecasts in all five regional grids in India. ► Opportunity exists to improve the performance of CEA forecasts.

  6. Sharp or broad pulse peak for high resolution instruments? Choice of moderator performance

    International Nuclear Information System (INIS)

    Arai, M.; Watanabe, N.; Teshigawara, M.

    2001-01-01

    We demonstrate a concept how we should choose moderator performance to realize required performance for instruments. Neutron burst pulse can be characterized with peak intensity, peak width and tail. Those can be controllable by designing moderator, i.e. material, temperature, shape, decoupling, poisoning and having premoderator. Hence there are large number of variable parameters to be determined. Here we discuss the required moderator performance for some typical examples, i.e. high resolution powder instrument, chopper instrument, high resolution back scattering machine. (author)

  7. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    Directory of Open Access Journals (Sweden)

    Thomas L. Stöggl

    2017-08-01

    Full Text Available The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR in well-trained endurance athletes.Methods: Thirty-six male (n = 33 and female (n = 3 runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak: 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT. A maximal anaerobic running/cycling test (MART/MACT was performed prior to and following a 9-week training period.Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001 and peak lactate (P = 0.001 during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L−1 was changed (P > 0.05. Acute HRR was improved in HIIT (11.2%, P = 0.002 and POL (7.9%, P = 0.023 with no change in the HVLIT oriented control group.Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT had no effect on any performance or HRR outcomes.

  8. Decomposition and correction overlapping peaks of LIBS using an error compensation method combined with curve fitting.

    Science.gov (United States)

    Tan, Bing; Huang, Min; Zhu, Qibing; Guo, Ya; Qin, Jianwei

    2017-09-01

    The laser induced breakdown spectroscopy (LIBS) technique is an effective method to detect material composition by obtaining the plasma emission spectrum. The overlapping peaks in the spectrum are a fundamental problem in the qualitative and quantitative analysis of LIBS. Based on a curve fitting method, this paper studies an error compensation method to achieve the decomposition and correction of overlapping peaks. The vital step is that the fitting residual is fed back to the overlapping peaks and performs multiple curve fitting processes to obtain a lower residual result. For the quantitative experiments of Cu, the Cu-Fe overlapping peaks in the range of 321-327 nm obtained from the LIBS spectrum of five different concentrations of CuSO 4 ·5H 2 O solution were decomposed and corrected using curve fitting and error compensation methods. Compared with the curve fitting method, the error compensation reduced the fitting residual about 18.12-32.64% and improved the correlation about 0.86-1.82%. Then, the calibration curve between the intensity and concentration of the Cu was established. It can be seen that the error compensation method exhibits a higher linear correlation between the intensity and concentration of Cu, which can be applied to the decomposition and correction of overlapping peaks in the LIBS spectrum.

  9. Performance test of Spectran-F and Spectran-III computer programs for resolving the 137Cs-110Ag double peak in gamma-ray spectrometric analysis

    International Nuclear Information System (INIS)

    Terada, H.; Malinowski, J.; Blick, H.

    1981-09-01

    The performance of the computer programs (Spectran F and Spectran-III) in resolving the 137 Cs-sup(110m)Ag double peak at 661.6-657.7 keV in the gamma-ray spectrum was investigated. In the experiments, the intensity ratios of both lines in the double peak were varied from 0.1 to 60. The results obtained show, that both programs have almost the same performance in resolving the double peak investigated, with slight superiority of Spectran-F. If accuracy better than 5% is desired, the peak intensity ratio in the dublet must be kept below 10. (orig.)

  10. High-intensity lower limb endurance training in chronic respiratory disease

    OpenAIRE

    Tanaka, Takako; Arizono, Shinichi; Hanada, Masatoshi; Senjyu, Hideaki

    2015-01-01

    High-intensity endurance training is mainly undertaken during pulmonary rehabilitation for patients with chronic respiratory disease. High-intensity endurance training is recommended in many clinical management guidelines. High-intensity endurance training involves training generally at an intensity of at 60-80% of the patient’s peak work capacity or higher. The effects of high-intensity lower limb endurance training have mostly been investigated in chronic obstructive pulmonary disease (COPD...

  11. Diurnal variations of summer precipitation over the regions east to Tibetan Plateau

    Science.gov (United States)

    Wu, Yang; Huang, Anning; Huang, Danqing; Chen, Fei; Yang, Ben; Zhou, Yang; Fang, Dexian; Zhang, Lujun; Wen, Lijuan

    2017-12-01

    Based on the hourly gauge-satellite merged precipitation product with the horizontal resolution of 0.1° latitude/longitude during 2008-2014, diurnal variations of the summer precipitation amount (PA), frequency (PF), and intensity (PI) with different duration time over the regions east to Tibetan Plateau have been systematically revealed in this study. Results indicate that the eight typical precipitation diurnal patterns identified by the cluster analysis display pronounced regional features among the plateaus, basins, plains, hilly and coastal areas. The precipitation diurnal cycles are significantly affected by the sub-grid terrain fluctuations. The PA, PF and PI of the total rainfall show much more pronounced double diurnal peaks with the sub-grid topography standard deviation (SD) decreased. Meanwhile, the diurnal peaks of PA and PF (PI) strengthen (weaken) with the sub-grid topography SD enhanced. Over the elevated mountain ranges, southeastern hilly and coastal regions, the PA and PF diurnal patterns of the total rainfall generally show predominant late-afternoon peaks, which are closely associated with the short-duration (≤slant 3 h) rainfall. Along the Tibetan Plateau to its downstream, the diurnal peaks of PA, PF and PI for the total rainfall all exhibit obvious eastward phase time delay mainly due to the diurnal evolutions of long-duration (> 6 h) rainfall. However, the 4-6 h rainfall leads to the eastward phase time delay of the total rainfall along the Taihang Mountains to its downstream. Further mechanism analysis suggests that the midnight to morning diurnal evolution of the long-duration rainfall is closely associated with the diurnal variations of the upward branches of thermally driven mountain-plain solenoids and the water vapor transport associated with the accelerated nocturnal southwesterly winds. The late-afternoon peak of the short-duration PA over the southeastern hilly and coastal regions is ascribed to the strong local thermal

  12. Phenotypic selection varies with pollination intensity across populations of Sabatia angularis.

    Science.gov (United States)

    Emel, Sarah L; Franks, Steven J; Spigler, Rachel B

    2017-07-01

    Pollinators are considered primary selective agents acting on plant traits, and thus variation in the strength of the plant-pollinator interaction might drive variation in the opportunity for selection and selection intensity across plant populations. Here, we examine whether these critical evolutionary parameters covary with pollination intensity across wild populations of the biennial Sabatia angularis. We quantified pollination intensity in each of nine S. angularis populations as mean stigmatic pollen load per population. For female fitness and three components, fruit number, fruit set (proportion of flowers setting fruit) and number of seeds per fruit, we evaluated whether the opportunity for selection varied with pollination intensity. We used phenotypic selection analyses to test for interactions between pollination intensity and selection gradients for five floral traits, including flowering phenology. The opportunity for selection via fruit set and seeds per fruit declined significantly with increasing pollen receipt, as expected. We demonstrated significant directional selection on multiple traits across populations. We also found that selection intensity for all traits depended on pollination intensity. Consistent with general theory about the relationship between biotic interaction strength and the intensity of selection, our study suggests that variation in pollination intensity drives variation in selection across S. angularis populations. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  13. Peak-interviewet

    DEFF Research Database (Denmark)

    Raalskov, Jesper; Warming-Rasmussen, Bent

    Peak-interviewet er en særlig effektiv metode til at gøre ubevidste menneskelige ressourcer bevidste. Fokuspersonen (den interviewede) interviewes om en selvvalgt, personlig succesoplevelse. Terapeuten/coachen (intervieweren) spørger ind til processen, som ledte hen til denne succes. Herved afdæk...... fokuspersonen ønsker at tage op (nye mål eller nye processer). Nærværende workingpaper beskriver, hvad der menes med et peak-interview, peakinterviwets teoretiske fundament samt metodikken til at foretage et tillidsfuldt og effektiv peak-interview....

  14. 'Peak oil' or 'peak demand'?

    International Nuclear Information System (INIS)

    Chevallier, Bruno; Moncomble, Jean-Eudes; Sigonney, Pierre; Vially, Rolland; Bosseboeuf, Didier; Chateau, Bertrand

    2012-01-01

    This article reports a workshop which addressed several energy issues like the objectives and constraints of energy mix scenarios, the differences between the approaches in different countries, the cost of new technologies implemented for this purposes, how these technologies will be developed and marketed, which will be the environmental and societal acceptability of these technical choices. Different aspects and issues have been more precisely presented and discussed: the peak oil, development of shale gases and their cost (will non conventional hydrocarbons modify the peak oil and be socially accepted?), energy efficiency (its benefits, its reality in France and other countries, its position in front of the challenge of energy transition), and strategies in the transport sector (challenges for mobility, evolution towards a model of sustainable mobility)

  15. Ultrafast, ultrahigh-peak power Ti:sapphire laser system

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Koichi; Aoyama, Makoto; Matsuoka, Shinichi; Akahane, Yutaka; Kase, Teiji; Nakano, Fumihiko; Sagisaka, Akito [Advanced Photon Research Center, Kansai Research Establishment, Japan Atomic Energy Research Inst., Kizu, Kyoto (Japan)

    2001-01-01

    We review progress in the generation of multiterawatt optical pulses in the 10-fs range. We describe a design, performance and characterization of a Ti:sapphire laser system based on chirped-pulse amplification, which has produced a peak power in excess of 100-TW with sub-20-fs pulse durations and an average power of 19-W at a 10-Hz repetition rate. We also discuss extension of this system to the petawatt power level and potential applications in the relativistic, ultrahigh intensity regimes. (author)

  16. Variations of radiation intensity as a function of position in radiation field of a mammographic unit of 760 mm SID with Mo anode and 20 μm Mo added filter

    International Nuclear Information System (INIS)

    Noriah Jamal

    2001-01-01

    There are many effects that contribute to radiation field nonuniformity in mammography, including the heel effect and shorter source to image distance (SID), inverse square law and different photon path lengths through various attenuating media (the x-ray tube beryllium window, the added filter, the mirror, and the compression paddle) throughout the field. Variations of radiation intensity was investigated as a function of position in the radiation field (with compression paddle in place)of a mammographic unit in 760 mm SID with Mo anode and 20 μm Mo added filter. Reduction in radiation intensity along central axis of up to 19.40%, 19.13% and 19.34% were noted at 24, 26 and 28 kVp respectively. Radiation intensity also drops off to the left and right of the central axis. As a function of position in the field, we also found that the variations of optical density correlate well with the measured radiation intensity changes. (Author)

  17. Peak Pc Prediction in Conjunction Analysis: Conjunction Assessment Risk Analysis. Pc Behavior Prediction Models

    Science.gov (United States)

    Vallejo, J.J.; Hejduk, M.D.; Stamey, J. D.

    2015-01-01

    Satellite conjunction risk typically evaluated through the probability of collision (Pc). Considers both conjunction geometry and uncertainties in both state estimates. Conjunction events initially discovered through Joint Space Operations Center (JSpOC) screenings, usually seven days before Time of Closest Approach (TCA). However, JSpOC continues to track objects and issue conjunction updates. Changes in state estimate and reduced propagation time cause Pc to change as event develops. These changes a combination of potentially predictable development and unpredictable changes in state estimate covariance. Operationally useful datum: the peak Pc. If it can reasonably be inferred that the peak Pc value has passed, then risk assessment can be conducted against this peak value. If this value is below remediation level, then event intensity can be relaxed. Can the peak Pc location be reasonably predicted?

  18. Kinetic quantification of plyometric exercise intensity.

    Science.gov (United States)

    Ebben, William P; Fauth, McKenzie L; Garceau, Luke R; Petushek, Erich J

    2011-12-01

    Ebben, WP, Fauth, ML, Garceau, LR, and Petushek, EJ. Kinetic quantification of plyometric exercise intensity. J Strength Cond Res 25(12): 3288-3298, 2011-Quantification of plyometric exercise intensity is necessary to understand the characteristics of these exercises and the proper progression of this mode of exercise. The purpose of this study was to assess the kinetic characteristics of a variety of plyometric exercises. This study also sought to assess gender differences in these variables. Twenty-six men and 23 women with previous experience in performing plyometric training served as subjects. The subjects performed a variety of plyometric exercises including line hops, 15.24-cm cone hops, squat jumps, tuck jumps, countermovement jumps (CMJs), loaded CMJs equal to 30% of 1 repetition maximum squat, depth jumps normalized to the subject's jump height (JH), and single leg jumps. All plyometric exercises were assessed with a force platform. Outcome variables associated with the takeoff, airborne, and landing phase of each plyometric exercise were evaluated. These variables included the peak vertical ground reaction force (GRF) during takeoff, the time to takeoff, flight time, JH, peak power, landing rate of force development, and peak vertical GRF during landing. A 2-way mixed analysis of variance with repeated measures for plyometric exercise type demonstrated main effects for exercise type and all outcome variables (p ≤ 0.05) and for the interaction between gender and peak vertical GRF during takeoff (p ≤ 0.05). Bonferroni-adjusted pairwise comparisons identified a number of differences between the plyometric exercises for the outcome variables assessed (p ≤ 0.05). These findings can be used to guide the progression of plyometric training by incorporating exercises of increasing intensity over the course of a program.

  19. Data Intensive Systems (DIS) Benchmark Performance Summary

    National Research Council Canada - National Science Library

    Musmanno, Joseph

    2003-01-01

    .... However, elements such as larger caches, prefetching, and multithreading do not address the needs of data-intensive DoD applications, which consequently operate at rates far below the peak processor- capacity...

  20. Spatiotemporal control of laser intensity

    Science.gov (United States)

    Froula, Dustin H.; Turnbull, David; Davies, Andrew S.; Kessler, Terrance J.; Haberberger, Dan; Palastro, John P.; Bahk, Seung-Whan; Begishev, Ildar A.; Boni, Robert; Bucht, Sara; Katz, Joseph; Shaw, Jessica L.

    2018-05-01

    The controlled coupling of a laser to plasma has the potential to address grand scientific challenges1-6, but many applications have limited flexibility and poor control over the laser focal volume. Here, we present an advanced focusing scheme called a `flying focus', where a chromatic focusing system combined with chirped laser pulses enables a small-diameter laser focus to propagate nearly 100 times its Rayleigh length. Furthermore, the speed at which the focus moves (and hence the peak intensity) is decoupled from the group velocity of the laser. It can co- or counter-propagate along the laser axis at any velocity. Experiments validating the concept measured subluminal (-0.09c) to superluminal (39c) focal-spot velocities, generating a nearly constant peak intensity over 4.5 mm. Among possible applications, the flying focus could be applied to a photon accelerator7 to mitigate dephasing, facilitating the production of tunable XUV sources.

  1. Neurofeedback training for peak performance.

    Science.gov (United States)

    Graczyk, Marek; Pąchalska, Maria; Ziółkowski, Artur; Mańko, Grzegorz; Łukaszewska, Beata; Kochanowicz, Kazimierz; Mirski, Andrzej; Kropotov, Iurii D

    2014-01-01

    One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneous EEG and event related potentials (ERPs). The case is presented of an Olympic athlete who has lost his performance confidence after injury in sport. He wanted to resume his activities by means of neurofeedback training. His QEEG/ERP parameters were assessed before and after 4 intensive sessions of neurotherapy. Dramatic and statistically significant changes that could not be explained by error measurement were observed in the patient. Neurofeedback training in the subject under study increased the amplitude of the monitoring component of ERPs generated in the anterior cingulate cortex, accompanied by an increase in beta activity over the medial prefrontal cortex. Taking these changes together, it can be concluded that that even a few sessions of neurofeedback in a high performance brain can significantly activate the prefrontal cortical areas associated with increasing confidence in sport performance.

  2. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    Science.gov (United States)

    Stöggl, Thomas L.; Björklund, Glenn

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes. Methods: Thirty-six male (n = 33) and female (n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak): 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT). A maximal anaerobic running/cycling test (MART/MACT) was performed prior to and following a 9-week training period. Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P 0.05). Acute HRR was improved in HIIT (11.2%, P = 0.002) and POL (7.9%, P = 0.023) with no change in the HVLIT oriented control group. Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT) had no effect on any performance or HRR outcomes. PMID:28824457

  3. Plasma and energetic electron flux variations in the Mercury 1 C event: Evidence for a magnetospheric boundary layer

    International Nuclear Information System (INIS)

    Christon, S.P.

    1989-01-01

    Near the outbound magnetopause crossing during the first encounter of Mariner 10 with the planet Mercury on March 29, 1974, large intensity, ∼ 6 s quasi-periodic variations in the intensity-time profile of the charged particle experiment's electron counting rate appeared as a series of peaks and valleys. The peaks have previously been interpreted as quasi-periodic burst sequences of mildly relativistic electrons, caused in one case by episodic ∼ 6-s magnetotail substorm reconnection events and in another case by multiple encounters with a substorm energized electron population drifting around Mercury with an ∼ 6 s drift period. In this paper, the authors offer a new and fundamentally different interpretation of the Mariner 10 energetic electron, plasma electron, and magnetic field data near the outbound magnetopause at Mercury 1. They show that magnetosheath-like boundary layer plasma was observed up to ∼ 360 km planetward of the dawn magnetopause crossing as sensed by the magnetometer. They show that observations of substorm enhanced > 35 keV electron flux (that previously interpreted as > 175 keV electrons) associated with the hot tenuous plasma sheet population were interleaved with ∼ 6 s period observations of a cold dense boundary layer plasma associated with a much lower > 35 keV electron flux. They argue that the ∼ 6 s temporal signature is due to variation of the thickness and/or position of the boundary layer plasma population. This explanation of the ∼ 6-s variations, based upon the analysis of the coincident responses of the magnetic field experiment and two independent charged particle instruments (at their highest temporal resolutions), finds a direct analogue in observations of Earth's magnetospheric boundary layer, although the time scales are significantly shorter at Mercury

  4. Correlation between ionospheric potential and the intensity of cosmic rays

    International Nuclear Information System (INIS)

    Meyerott, R.E.; Reagan, J.B.; Evans, J.E.

    1983-01-01

    Ionospheric potential variations with a period of about 10 yr have been observed in the data that have been acquired to date. Previous studies have shown that these variations appear to be correlated inversely with sunspot number and with solar wind velocity, and directly with cosmic ray intensity. Since the cosmic ray intensity is inversely correlated with sunspot number and solar wind velocity, these correlations all suggest that the long period variations are of solar origin. In this report it is shown that, over the limited period for which ionospheric potential measurements exist, the long period variations are better correlated with the aerosol burden injected into the stratosphere by large volcanic eruptions than with the intensity of cosmic rays. This result indicates that the long period variations in ionospheric potential are of terrestrial rather than solar origin. 20 references

  5. How We Remember the Emotional Intensity of Past Musical Experiences

    Directory of Open Access Journals (Sweden)

    Thomas eSchäfer

    2014-08-01

    Full Text Available Listening to music usually elicits emotions that can vary considerably in their intensity over the course of listening. Yet, after listening to a piece of music, people are easily able to evaluate the music’s overall emotional intensity. There are two different hypotheses about how affective experiences are temporally processed and integrated: (1 all moments’ intensities are integrated, resulting in an averaged value; (2 the overall evaluation is built from specific single moments, such as the moments of highest emotional intensity (peaks, the end, or a combination of these. Here we investigated what listeners do when building an overall evaluation of a musical experience. Participants listened to unknown songs and provided moment-to-moment ratings of experienced intensity of emotions. Subsequently, they evaluated the overall emotional intensity of each song. Results indicate that participants’ evaluations were predominantly influenced by their average impression but that, in addition, the peaks and end emotional intensities contributed substantially. These results indicate that both types of processes play a role: All moments are integrated into an averaged value but single moments might be assigned a higher value in the calculation of this average.

  6. No association between gender inequality and peak HIV prevalence in developing countries - an ecological study.

    Science.gov (United States)

    Kenyon, Chris R; Buyze, Jozefien

    2015-01-01

    The prevalence of both gender inequality and HIV prevalence vary considerably both within all developing countries and within those in sub-Saharan Africa. We test the hypothesis that the extent of gender inequality is associated with national peak HIV prevalence. Linear regression was used to test the association between national peak HIV prevalence and three markers of gender equality - the gender-related development index (GDI), the gender empowerment measure (GEM), and the gender inequality index (GII). No evidence was found of a positive relationship between gender inequality and HIV prevalence, either in the analyses of all developing countries or those limited to Africa. In the bivariate analyses limited to Africa, there was a positive association between the two measures of gender "equality" and peak HIV prevalence (GDI: coefficient 28, 95% confidence interval (CI) 9.1-46.8; GEM: coefficient 54.8, 95% CI 20.5-89.1). There was also a negative association between the marker of gender "inequality" and peak HIV prevalence (GII: coefficient -66.9, 95% CI -112.8 to -21.0). These associations all disappeared on multivariate analyses. We could not find any evidence to support the hypothesis that variations in the extent of gender inequality explain variations in HIV prevalence in developing countries.

  7. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis.

    Science.gov (United States)

    Baumgart, Julia Kathrin; Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Systematic literature review and meta-analysis. PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in sports with few

  8. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis.

    Directory of Open Access Journals (Sweden)

    Julia Kathrin Baumgart

    Full Text Available Peak oxygen uptake (VO2peak in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested.To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak.Systematic literature review and meta-analysis.PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean.Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included.Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak.Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in

  9. Isotopic composition of water in precipitation due to seasonal variation and variation in intensity of rain fall at a place

    International Nuclear Information System (INIS)

    Singh, B.P.

    2015-01-01

    An attempt has been made to analyze the data to find the original precipitate on GMWL, when there is seasonal variation and variations in intensity of rain fall at the same longitude, latitude and altitude. This has been done using the data as available for each month, weighted average of month and individual year for δ 2 H and δ 18 O for a 10-year periods. Correlation equations between δ 2 H and δ 18 O are available giving slopes and intercepts on the δ 2 H axis for 10-year periods. The data of slope versus intercept for each month, weighted monthly average value and individual year are plotted to arrive at isotope composition of meteoric water δ 18 O and δ 2 H, the method suggested by (Singh B.P. 2013, Isotopic composition of water in precipitation in a region or place, Applied Radiation and Isotopes, vol. 75, pp. 22–25; Singh B.P. 2014, Isotopic composition of river water across a continent, Applied Radiation and Isotopes, vol. 85, pp. 14–18). The results of the original meteoric isotopic composition of water are within the experimental errors as analyzed on a yearly basis, the average of each month of yearly basis and on the basis of each month and also some different amounts of precipitation giving the same value of δ 18 O=−16.72 and δ 2 H=−129.86 on GMWL. - Highlights: • New pattern, plot of slope versus intercept between δ 18 O and δ 2 H at the same location for seasons and rainfall are given. • These patterns are analyzed to arrive at the original isotopic composition to be on GMWL. • It is found that the original isotopic composition is same for different seasons and amount of rainfall

  10. Cosmic ray intensity distribution in the vertical direction to solar equator plane

    International Nuclear Information System (INIS)

    Nosaka, Toru; Mori, Satoru; Sagisaka, Shuji.

    1983-01-01

    The data of the annual variation of cosmic ray intensity measured by neutron detectors were used to study the distribution of cosmic ray intensity vertical to the solar equator plane and its long term variation. The data used were obtained at Deep River, Kiel, Kerguelen Island, McMurdo, Ottawa, and Mt. Washington. All data showed annual variation. The patterns and degree of variation obtained in northern and southern hemisphere were similar. The summation dial representation of the annual variation and semi-annual variation of cosmic ray was obtained. The inversion of annual variation in 1958 - 1959 and 1968 - 1969 corresponded to the inversion of polarity of solar pole magnetic field. The semi-annual variation showed a complex behavior. The helio-latitudial distribution of cosmic ray intensity was obtained. The asymmetric distribution in relation to the solar equator was observed in the annual variation. The northward gradient of density in 1955 - 1958 and southward gradient in 1959 - 1968 were seen. (Kato, T.)

  11. Periodic variations of cosmic ray intensity with period of -37 minute observed on April 25th, 1984

    International Nuclear Information System (INIS)

    Sakai, Takasuke; Kato, Masahito; Takei, Ryoji; Tamai, Eiji

    1985-01-01

    Existence of cosmic ray variation with period ranging from a few hours to seconds during geomagnetically quiet and perturb period at different altitude with different detector, was reported previously. As short period variation is thought to be transient with small amplitude fluctuation, consequently high counting rate of cosmic ray and appropriate method for finding short periodicity, is required. Further, there is similar phenomenon in which short variation, followed by storm sudden commencement (SSC) and/or Forbush decrease (FD) occurs. In 1979, Kato et al. used 3 minutes data at Mt. Norikura and obtained -6 x 10 5 count/min, and tried to find out short periodicity of cosmic ray around SSC, but no clear conclusion was obtained. T. Sakai, et al., used plastic scintillation counter of Akeno observatory, following their preceding work. The counter has an area about 154 m 2 . High counting rate of -2 x 10 6 counts/min. was observed at Akeno which revealed the existence of -37 minute periodical oscillation with an amplitude of 0.1 % in p-p during the time period of 1300 - 1900 UT on April 25th 1984, one day before FD. Observed periodical oscillation of cosmic ray counting rate may be the result of the changes in magnetic field. But, it must be noted that there remains possibility of oscillation of cosmic ray intensity in the interplanetary space during the period, independent of geomagnetic field. (author)

  12. Holographic wavefront characterization of a frequency-tripled high-peak-power neodymium:glass laser

    International Nuclear Information System (INIS)

    Kessler, T.J.

    1984-01-01

    Near-field amplitude and phase distributions from a high-peak-power, frequency converted Nd:glass laser (lambda = 351 nm) have been holographically recorded on silver-halide emulsions. Conventionally, the absence of a suitable reference beam forces one to use some type of shearing interferometry to obtain phasefront information, while the near-field and far-field distributions are recorded as intensity profiles. In this study, a spatially filtered, locally generated reference beam was created to holographically store the complex amplitude distribution of the pulsed laser beam, while reconstruction of the original wavefront was achieved with a continuous-wave laser. Reconstructed near-field and quasi-far-field intensity distributions closely resembled those obtained from conventional techniques, and accurate phasefront reconstruction was achieved. Furthermore, several two-beam interferometric techniques, not practicable with a high-peak-power laser, have been successfully implemented on a continuous-wave reconstruction of the pulsed laser beam. 46 refs., 40 figs., 1 tab

  13. MRI intensity inhomogeneity correction by combining intensity and spatial information

    International Nuclear Information System (INIS)

    Vovk, Uros; Pernus, Franjo; Likar, Bostjan

    2004-01-01

    We propose a novel fully automated method for retrospective correction of intensity inhomogeneity, which is an undesired phenomenon in many automatic image analysis tasks, especially if quantitative analysis is the final goal. Besides most commonly used intensity features, additional spatial image features are incorporated to improve inhomogeneity correction and to make it more dynamic, so that local intensity variations can be corrected more efficiently. The proposed method is a four-step iterative procedure in which a non-parametric inhomogeneity correction is conducted. First, the probability distribution of image intensities and corresponding second derivatives is obtained. Second, intensity correction forces, condensing the probability distribution along the intensity feature, are computed for each voxel. Third, the inhomogeneity correction field is estimated by regularization of all voxel forces, and fourth, the corresponding partial inhomogeneity correction is performed. The degree of inhomogeneity correction dynamics is determined by the size of regularization kernel. The method was qualitatively and quantitatively evaluated on simulated and real MR brain images. The obtained results show that the proposed method does not corrupt inhomogeneity-free images and successfully corrects intensity inhomogeneity artefacts even if these are more dynamic

  14. Variation of the binary encounter peak energy as a function of projectile atomic number

    International Nuclear Information System (INIS)

    Sanders, J.M.

    1994-01-01

    The energy of the binary encounter peak, in spectra of electrons emitted at 0 degrees with respect to the projectile beam direction, has been studied to investigate its dependence on the atomic number of the projectile ion. The projectiles all had the same squared velocity of 0.6 MeV/u, and all had the same charge q=7. The Z of the projectiles ranged from 8 to 35, and the target was H 2 . The Energy E BEP of the binary encounter peak and also the energy t of the cusp formed by electron loss or electron capture to the projectile continuum (ELC or ECC) were obtained from fits to the spectra. Considerable care was required in fitting the cusp in order to properly ascertain the cusp energy. The energy shift ΔE, defined as the difference between 4t and E BEP , was obtained for each projectile. It is found that the energy shift decreases as the projectile Z increases. This trend is the opposite of that seen for projectile charge where the shift increases as q increases. Such a trend is not well described by the simple elastic scattering model of binary encounter electron production

  15. Probabilistic peak detection in CE-LIF for STR DNA typing.

    Science.gov (United States)

    Woldegebriel, Michael; van Asten, Arian; Kloosterman, Ate; Vivó-Truyols, Gabriel

    2017-07-01

    In this work, we present a novel probabilistic peak detection algorithm based on a Bayesian framework for forensic DNA analysis. The proposed method aims at an exhaustive use of raw electropherogram data from a laser-induced fluorescence multi-CE system. As the raw data are informative up to a single data point, the conventional threshold-based approaches discard relevant forensic information early in the data analysis pipeline. Our proposed method assigns a posterior probability reflecting the data point's relevance with respect to peak detection criteria. Peaks of low intensity generated from a truly existing allele can thus constitute evidential value instead of fully discarding them and contemplating a potential allele drop-out. This way of working utilizes the information available within each individual data point and thus avoids making early (binary) decisions on the data analysis that can lead to error propagation. The proposed method was tested and compared to the application of a set threshold as is current practice in forensic STR DNA profiling. The new method was found to yield a significant improvement in the number of alleles identified, regardless of the peak heights and deviation from Gaussian shape. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Time-resolved measurement of emission profiles in pulsed radiofrequency glow discharge optical emission spectroscopy: Investigation of the pre-peak

    International Nuclear Information System (INIS)

    Alberts, D.; Horvath, P.; Nelis, Th.; Pereiro, R.; Bordel, N.; Michler, J.; Sanz-Medel, A.

    2010-01-01

    Radiofrequency glow discharge coupled to optical emission spectroscopy has been used in pulsed mode in order to perform a detailed study of the measured temporal emission profiles for a wide range of copper transitions. Special attention has been paid to the early emission peak (or so-called pre-peak), observed at the beginning of the emission pulse profile. The effects of the important pulse parameters such as frequency, duty cycle, pulse width and power-off time, have been studied upon the Cu pulse emission profiles. The influence of discharge parameters, such as pressure and power, was studied as well. Results have shown that the intensity observed in the pre-peak can be 10 times as large as the plateau value for resonant lines and up to 5 times in case of transitions to the metastable levels. Increasing pressure or power increased the pre-peak intensity while its appearance in time changed. The pre-peak decreased when the discharge off-time was shorter than 100 μs. According to such results, the presence of the pre-peak could be probably due to the lack of self-absorption during the first 50 μs, and not to the ignition of the plasma. Under the selected operation conditions, the use of the pre-peak emission as analytical signals increases the linearity of calibration curves for resonant lines subjected to self-absorption at high concentrations.

  17. Time-resolved measurement of emission profiles in pulsed radiofrequency glow discharge optical emission spectroscopy: Investigation of the pre-peak

    Energy Technology Data Exchange (ETDEWEB)

    Alberts, D. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain); Horvath, P. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Feuerwerkerstrasse 39, 3602 Thun (Switzerland); Nelis, Th. [LAPLACE, Universite Paul Sabatier, 118 rte de Narbonne, Bat3R2, 31062 Toulouse Cedex (France); CU Jean Francois Champollion, Place de Verdun 81012 Albi Cedex 9 (France); Pereiro, R. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain); Bordel, N. [Department of Physics, Faculty of Science, University of Oviedo, Calvo Sotelo, 33007 Oviedo (Spain); Michler, J. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Feuerwerkerstrasse 39, 3602 Thun (Switzerland); Sanz-Medel, A., E-mail: asm@uniovi.e [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain)

    2010-07-15

    Radiofrequency glow discharge coupled to optical emission spectroscopy has been used in pulsed mode in order to perform a detailed study of the measured temporal emission profiles for a wide range of copper transitions. Special attention has been paid to the early emission peak (or so-called pre-peak), observed at the beginning of the emission pulse profile. The effects of the important pulse parameters such as frequency, duty cycle, pulse width and power-off time, have been studied upon the Cu pulse emission profiles. The influence of discharge parameters, such as pressure and power, was studied as well. Results have shown that the intensity observed in the pre-peak can be 10 times as large as the plateau value for resonant lines and up to 5 times in case of transitions to the metastable levels. Increasing pressure or power increased the pre-peak intensity while its appearance in time changed. The pre-peak decreased when the discharge off-time was shorter than 100 {mu}s. According to such results, the presence of the pre-peak could be probably due to the lack of self-absorption during the first 50 {mu}s, and not to the ignition of the plasma. Under the selected operation conditions, the use of the pre-peak emission as analytical signals increases the linearity of calibration curves for resonant lines subjected to self-absorption at high concentrations.

  18. Strongly intensive quantities

    International Nuclear Information System (INIS)

    Gorenstein, M. I.; Gazdzicki, M.

    2011-01-01

    Analysis of fluctuations of hadron production properties in collisions of relativistic particles profits from use of measurable intensive quantities which are independent of system size variations. The first family of such quantities was proposed in 1992; another is introduced in this paper. Furthermore we present a proof of independence of volume fluctuations for quantities from both families within the framework of the grand canonical ensemble. These quantities are referred to as strongly intensive ones. Influence of conservation laws and resonance decays is also discussed.

  19. Ultrasonic Transducer Peak-to-Peak Optical Measurement

    Directory of Open Access Journals (Sweden)

    Pavel Skarvada

    2012-01-01

    Full Text Available Possible optical setups for measurement of the peak-to-peak value of an ultrasonic transducer are described in this work. The Michelson interferometer with the calibrated nanopositioner in reference path and laser Doppler vibrometer were used for the basic measurement of vibration displacement. Langevin type of ultrasonic transducer is used for the purposes of Electro-Ultrasonic Nonlinear Spectroscopy (EUNS. Parameters of produced mechanical vibration have to been well known for EUNS. Moreover, a monitoring of mechanical vibration frequency shift with a mass load and sample-transducer coupling is important for EUNS measurement.

  20. The match-to-match variation of match-running in elite female soccer.

    Science.gov (United States)

    Trewin, Joshua; Meylan, César; Varley, Matthew C; Cronin, John

    2018-02-01

    The purpose of this study was to examine the match-to-match variation of match-running in elite female soccer players utilising GPS, using full-match and rolling period analyses. Longitudinal study. Elite female soccer players (n=45) from the same national team were observed during 55 international fixtures across 5 years (2012-2016). Data was analysed using a custom built MS Excel spreadsheet as full-matches and using a rolling 5-min analysis period, for all players who played 90-min matches (files=172). Variation was examined using co-efficient of variation and 90% confidence limits, calculated following log transformation. Total distance per minute exhibited the smallest variation when both the full-match and peak 5-min running periods were examined (CV=6.8-7.2%). Sprint-efforts were the most variable during a full-match (CV=53%), whilst high-speed running per minute exhibited the greatest variation in the post-peak 5-min period (CV=143%). Peak running periods were observed as slightly more variable than full-match analyses, with the post-peak period very-highly variable. Variability of accelerations (CV=17%) and Player Load (CV=14%) was lower than that of high-speed actions. Positional differences were also present, with centre backs exhibiting the greatest variation in high-speed movements (CV=41-65%). Practitioners and researchers should account for within player variability when examining match performances. Identification of peak running periods should be used to assist worst case scenarios. Whilst micro-sensor technology should be further examined as to its viable use within match-analyses. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  1. Short-term high-intensity interval and moderate-intensity continuous training reduce leukocyte TLR4 in inactive adults at elevated risk of type 2 diabetes

    Science.gov (United States)

    Robinson, Emily; Durrer, Cody; Simtchouk, Svetlana; Jung, Mary E.; Bourne, Jessica E.; Voth, Elizabeth

    2015-01-01

    Exercise can have anti-inflammatory effects in obesity, but the optimal type and intensity of exercise are not clear. This study compared short-term high-intensity interval training (HIIT) with moderate-intensity continuous training (MICT) in terms of improvement in cardiorespiratory fitness, markers of inflammation, and glucose control in previously inactive adults at elevated risk of developing type 2 diabetes. Thirty-nine inactive, overweight/obese adults (32 women) were randomly assigned to 10 sessions over 2 wk of progressive HIIT (n = 20, four to ten 1-min sessions at ∼90% peak heart rate, 1-min rest periods) or MICT (n = 19, 20-50 min at ∼65% peak heart rate). Before and 3 days after training, participants performed a peak O2 uptake test, and fasting blood samples were obtained. Both HIIT (1.8 ± 0.4 vs. 1.9 ± 0.4 l/min, pre vs. post) and MICT (1.8 ± 0.5 vs. 1.9 ± 0.5 l/min, pre vs. post) improved peak O2 uptake (P HIIT and MICT (P HIIT and MICT (P HIIT or MICT can improve cardiorespiratory fitness and glucose control and lead to reductions in TLR2 and TLR4 expression. MICT, which involved a longer duration of exercise, may be superior for reducing fasting glucose. PMID:26139217

  2. Comparison of the TL intensity of the sintered composites of CaSO4+Tm

    International Nuclear Information System (INIS)

    Junot, O.D.; Sousa, F.L. de; Chagas, M.A.P.; Souza, D.N.

    2009-01-01

    The objective of this work is to compare the thermoluminescent intensity (TL) of CaSO 4 +Tm, CaSO 4 +Tm+glass and glass+Tm composites for use as thermoluminescent dosimeter (TLD). The route used to prepare the CaSO 4 +Tm and the CaSO 4 +Tm+glass was by mixing 1 g of CaSO 4 with 0.02 g of thulium oxide (99,9% purity) and 0.3 g of commercial and colorless glass. To mixing the composites were taken to a magnetic stirrer for 30 min with 10 mL of distilled water for better homogenization. The powder mixtures were dried in a stove at 100 deg C for 24 h. After drying, it was added polyvinyl alcohol (PVA) to improve the binding material. The pellets were compacted by application of an uniaxial pressing and sintered at 700 deg C/ 6 h. The route used in the preparation of glass+Tm pellets was similar to one previously mentioned, except by the use of 1 g of glass and 0.02 of Tm. After the sintering, the pellets dimensions were 1 mm thick and 6 mm in diameter. All samples were irradiated by a beta source ( 90 Sr + 90 Y) and received doses from 1.00 Gy to 20 Gy. Each composite presented a characteristic emission curve. The dosimeter of CaSO 4 +Tm+glass presented two peaks, the first at 115 deg C, and the second, very intense, ate 150 deg C. The CaSO 4 +Tm dosimeter showed a less intense peak at 140 deg C and another, more intense, at 235 deg C. In the composites of glass+Tm, the most intense peak has a thermoluminescent signal 94,04% lower than the most intense peak of CaSO 4 +Tm+glass and 81.57% lower than the most intense peak of CaSO 4 +Tm. After the analysis of TL emission curves, we observed that the CaSO 4 +Tm+glass have the highest TL intensity and a TL response proportional to the dose absorbed. (author)

  3. Decomposing the variation of aggregate electricity intensity in Spanish industry

    International Nuclear Information System (INIS)

    Gonzalez, P.F.; Suarez, R.P.

    2003-01-01

    Several papers have dealt with methodological and application issues related to techniques for decomposing changes in environmental indicators. This paper aims to decompose changes in electricity intensity in Spanish industry and to explain the factors that contribute to these changes. Focusing on an energy intensity approach based on Divisia indices, we began by reviewing the two general parametric Divisia methods and six specific cases. In order to avoid obtaining significantly different results by using differing methods, all of them have been applied to Spanish data. Also two different disaggregation levels have been taken into consideration. Combined with electricity price analysis, the results of this paper indicate the poor contribution of structural change to substantial reductions in aggregate electricity intensity, and underline the role of innovation, development, diffusion and access to more efficient technologies as main contributors to the reduction of the energy/production ratio. (author)

  4. Between-game variation of physical soccer performance measures in highly trained youth soccer players.

    Science.gov (United States)

    Doncaster, Greg; Unnithan, Viswanath

    2017-07-12

    To assess the between-game variation in measures of physical performance during 11 v 11 soccer match-play, over a short period of time, in highly trained youth soccer players. A single cohort observational study design was employed. Physical match performance data were collected from 17 male, highly trained youth soccer players (age: 13.3 ± 0.4 y) over three, 2 x 20min, 11 v 11 matches. Using 10 Hz GPS, the variables selected for analyses were total distance (TD), high-speed running (HSR), very high-speed running (VHSR), number of high-speed running efforts (HSReff) and number of very high-speed running efforts (VHSReff). Match data was also separated into cumulative 5 min epochs, to identify the peak 5 min epoch and the mean of the cumulative 5 min epochs for each match. Variability was quantified using the coefficient of variation (CV), Standard error of measurement (SEM) and intra-class correlation coefficient (ICC). Between- and within-player smallest worthwhile changes (SWC) were also calculated for each variable to aid in the interpretation of the data. Analysis of the variance between games reported a low CV for TD (3.8%) but larger CVs for HSR (33.3%), HSReff (35.4%) and VHSR and VHSReff (59.6 and 57.4 %, respectively). Analysis of 5 min epochs (peak and average) found an increase in the CVs beyond that of the values reported for the whole match. Between-player SWC in high intensity physical performance data ranged from 24.7 - 42.4 %, whereas within-player SWC ranged from 1.2 - 79.9%. The between-game variability of high and very high intensity activities in youth soccer players, across three soccer matches over a short period of time (2 weeks), is relatively 'large' and specific to the individual, thus highlighting the need for caution when interpreting physical performance data between games and players.

  5. Characterising phase variations in MALDI-TOF data and correcting

    Directory of Open Access Journals (Sweden)

    Michael C Fitzgerald

    2005-01-01

    Full Text Available Abstract: The use of MALDI-TOF mass spectrometry as a means of analyzing the proteome has been evaluated extensively in recent years. One of the limitations of this technique that has impeded the development of robust data analysis algorithms is the variability in the location of protein ion signals along the x-axis. We studied technical variations of MALDI-TOF measurements in the context of proteomics profiling. By acquiring a benchmark data set with five replicates, we estimated 76% to 85% of the total variance is due to phase variation. We devised a lobster plot, so named because of the resemblance to a lobster claw, to help detect the phase variation in replicates. We also investigated a peak alignment algorithm to remove the phase variation. This operation is analogous to the normalization step in microarray data analysis. Only after this critical step can features of biological interest be clearly revealed. With the help of principal component analysis, we demonstrated that after peak alignment, the differences among replicates are reduced. We compared this approach to peak alignment with a model-based calibration approach in which there was known information about peaks in common among all spectra. Finally, we examined the potential value at each point in an analysis pipeline of having a set of methods available that includes parametric, semiparametric and nonparametric methods; among such methods are those that benefit from the use of prior information.

  6. Percent voluntary inactivation and peak force predictions with the interpolated twitch technique in individuals with high ability of voluntary activation

    International Nuclear Information System (INIS)

    Herda, Trent J; Walter, Ashley A; Hoge, Katherine M; Stout, Jeffrey R; Costa, Pablo B; Ryan, Eric D; Cramer, Joel T

    2011-01-01

    The purpose of this study was to examine the sensitivity and peak force prediction capability of the interpolated twitch technique (ITT) performed during submaximal and maximal voluntary contractions (MVCs) in subjects with the ability to maximally activate their plantar flexors. Twelve subjects performed two MVCs and nine submaximal contractions with the ITT method to calculate percent voluntary inactivation (%VI). Additionally, two MVCs were performed without the ITT. Polynomial models (linear, quadratic and cubic) were applied to the 10–90% VI and 40–90% VI versus force relationships to predict force. Peak force from the ITT MVC was 6.7% less than peak force from the MVC without the ITT. Fifty-eight percent of the 10–90% VI versus force relationships were best fit with nonlinear models; however, all 40–90% VI versus force relationships were best fit with linear models. Regardless of the polynomial model or the contraction intensities used to predict force, all models underestimated the actual force from 22% to 28%. There was low sensitivity of the ITT method at high contraction intensities and the predicted force from polynomial models significantly underestimated the actual force. Caution is warranted when interpreting the % VI at high contraction intensities and predicted peak force from submaximal contractions

  7. MODIS derived fire characteristics and aerosol optical depth variations during the agricultural residue burning season, north India

    International Nuclear Information System (INIS)

    Vadrevu, Krishna Prasad; Ellicott, Evan; Badarinath, K.V.S.; Vermote, Eric

    2011-01-01

    Agricultural residue burning is one of the major causes of greenhouse gas emissions and aerosols in the Indo-Ganges region. In this study, we characterize the fire intensity, seasonality, variability, fire radiative energy (FRE) and aerosol optical depth (AOD) variations during the agricultural residue burning season using MODIS data. Fire counts exhibited significant bi-modal activity, with peak occurrences during April-May and October-November corresponding to wheat and rice residue burning episodes. The FRE variations coincided with the amount of residues burnt. The mean AOD (2003-2008) was 0.60 with 0.87 (+1σ) and 0.32 (-1σ). The increased AOD during the winter coincided well with the fire counts during rice residue burning season. In contrast, the AOD-fire signal was weak during the summer wheat residue burning and attributed to dust and fossil fuel combustion. Our results highlight the need for 'full accounting of GHG's and aerosols', for addressing the air quality in the study area. - Highlights: → MODIS data could capture rice and wheat residue burning events. → The total FRP was high during the rice burning season than the wheat. → MODIS AOD variations coincided well with rice burning events than wheat. → AOD values exceeding one suggested intense air pollution. - This research work highlights the satellite derived fire products and their potential in characterizing the agricultural residue burning events and air pollution.

  8. Effect of transmission intensity on hotspots and micro-epidemiology of malaria in sub-Saharan Africa.

    Science.gov (United States)

    Mogeni, Polycarp; Omedo, Irene; Nyundo, Christopher; Kamau, Alice; Noor, Abdisalan; Bejon, Philip

    2017-06-30

    Malaria transmission intensity is heterogeneous, complicating the implementation of malaria control interventions. We provide a description of the spatial micro-epidemiology of symptomatic malaria and asymptomatic parasitaemia in multiple sites. We assembled data from 19 studies conducted between 1996 and 2015 in seven countries of sub-Saharan Africa with homestead-level geospatial data. Data from each site were used to quantify spatial autocorrelation and examine the temporal stability of hotspots. Parameters from these analyses were examined to identify trends over varying transmission intensity. Significant hotspots of malaria transmission were observed in most years and sites. The risk ratios of malaria within hotspots were highest at low malaria positive fractions (MPFs) and decreased with increasing MPF (p hotspots was lowest at extremely low and extremely high MPFs, with a peak in statistical significance at an MPF of ~0.3. In four sites with longitudinal data we noted temporal instability and variable negative correlations between MPF and average age of symptomatic malaria across all sites, suggesting varying degrees of temporal stability. We observed geographical micro-variation in malaria transmission at sites with a variety of transmission intensities across sub-Saharan Africa. Hotspots are marked at lower transmission intensity, but it becomes difficult to show statistical significance when cases are sparse at very low transmission intensity. Given the predictability with which hotspots occur as transmission intensity falls, malaria control programmes should have a low threshold for responding to apparent clustering of cases.

  9. Temperature peaks affect fire-induced soil water repellency, infiltration and erosion risk of Mediterranean shrublands. Implications for water and sediment connectivity

    Science.gov (United States)

    Jordán, Antonio; Zavala, Lorena M.; Gordillo-Rivero, Ángel J.; Miriam, Miriam; Keesstra, Saskia; Cerdà, Artemi

    2017-04-01

    We know that the impact of fire on soil water repellency varies largely with the availability of water and physical and chemical soil properties, as well as the intensity of pre-existing hydrophobicity. However, there are few studies that relate the intensity of post-fire soil hydrophobicity and its persistence to the intensity and duration of thermal peaks occurring during fire. Fundamentally, this is due to the difficulty of quantifying these factors in situ, so that experimental fires are an extremely useful tool. The objective of this work was to study the impact of the intensity and duration of the thermal peaks observed during an experimental fire in the hydrophobicity of previously wet or slightly hydrophobic soils and the consequences of these changes on infiltration, runoff and soil loss (through rainfall simulation) in the immediate (30 days) and medium-term (1 year) post-fire period. In general, soil water repellency increased in all cases, although high temperatures and residence times of moderate thermal peaks caused the greatest impact. Although infiltration rates determined by mini-disk infiltrometer with water generally declined, no significant changes were observed in the same measurement with ethanol (which negates the effect of hydrophobicity).

  10. Experimental study of proton acceleration with ultra-high intensity, high contrast laser beam

    International Nuclear Information System (INIS)

    Flacco, A.

    2008-07-01

    This thesis reports experimental work in the domain of laser-matter interaction to study the production of energetic proton beams. The ion beams accelerated by laser have been increasing in quality, in energy and in repeatability as laser technology keeps improving. The presence of the pedestal before the high peak laser pulse introduces many unknowns in the accelerating conditions that are created on the front and on the rear surface of the target. The first part of the experimental activities is focused to a better comprehension and the experimental validation of the interaction of a 'pedestal-like', moderate intensity, laser pulse on Aluminum targets. The developed interferometric technique proved to be reliable and produced a complete set of maps of the early stages of the plasma expansion. The reflectometry experiment stresses the importance of the quality of the metallic targets and underlines some obscure points on the behaviour of the rear surface of the illuminated foil. For instance the reflectometry measurements on the thicker targets are significantly different from what is foreseen by the simulations about the timescale of the shock break out. In the second part, the XPW laser pulse is used in ion acceleration from thin metal foils. The laser and target parameters are varied to put in evidence the dependence of the ion beam to the experimental condition. In conclusion I can say that first, during the variation of the target thickness, an optimum is put in evidence. Secondly, the correlation between the laser pulse duration and the proton cutoff energy is qualitatively different between thicker (15 μm) and thinner (1.5 μm, 3 μm) targets. For the first, an optimal pulse duration exists while for the seconds, no variation is found - in the searched space - from the monotonic decreasing of the cutoff energy with the peak intensity. The experimental results put however in evidence some points that are not completely understood. (A.C.)

  11. Neurofeedback training for peak performance

    Directory of Open Access Journals (Sweden)

    Marek Graczyk

    2014-11-01

    Full Text Available [b]aim[/b]. One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneous EEG and event related potentials (ERPs. [b]case study[/b]. The case is presented of an Olympic athlete who has lost his performance confidence after injury in sport. He wanted to resume his activities by means of neurofeedback training. His QEEG/ERP parameters were assessed before and after 4 intensive sessions of neurotherapy. Dramatic and statistically significant changes that could not be explained by error measurement were observed in the patient. [b]conclusion[/b]. Neurofeedback training in the subject under study increased the amplitude of the monitoring component of ERPs generated in the anterior cingulate cortex, accompanied by an increase in beta activity over the medial prefrontal cortex. Taking these changes together, it can be concluded that that even a few sessions of neurofeedback in a high performance brain can significantly activate the prefrontal cortical areas associated with increasing confidence in sport performance.

  12. VARIATIONS OF SOME NUTRITION VALUES OF OLIVE OIL BY HOUSEHOLD USING

    Directory of Open Access Journals (Sweden)

    Zita Jenisová

    2014-02-01

    Full Text Available This study examines of virgin olive oil variations after microwave heating, boiling in vinegar or salt solution, as well as UV irradiation. The heating and UV irradiation were performed using both continuous and discontinuous profiles. Measurements of selected nutrition values involving chlorophylls, carotenoids and alpha-tocopherol contents were carried out applying visible and fluorescence spectrometry. Development of fatty acid oxidation products was verified from relation of intensity ratio of 445/520 nm peaks in fluorescence spectrum. The continual microwave heating or UV irradiation showed results different from those using the discontinuous exposure despite the same cumulative treatment time. Chlorophylls and carotenoids were less sensible to the treatment than alpha-tocopherol. The boiling with the vinegar solution affected each from the followed components more destructively than the salt medium.

  13. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis

    Science.gov (United States)

    Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Background Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. Objectives To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Design Systematic literature review and meta-analysis. Data sources PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Eligibility criteria Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data synthesis Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Results Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1

  14. A revised ground-motion and intensity interpolation scheme for shakemap

    Science.gov (United States)

    Worden, C.B.; Wald, D.J.; Allen, T.I.; Lin, K.; Garcia, D.; Cua, G.

    2010-01-01

    We describe a weighted-average approach for incorporating various types of data (observed peak ground motions and intensities and estimates from groundmotion prediction equations) into the ShakeMap ground motion and intensity mapping framework. This approach represents a fundamental revision of our existing ShakeMap methodology. In addition, the increased availability of near-real-time macroseismic intensity data, the development of newrelationships between intensity and peak ground motions, and new relationships to directly predict intensity from earthquake source information have facilitated the inclusion of intensity measurements directly into ShakeMap computations. Our approach allows for the combination of (1) direct observations (ground-motion measurements or reported intensities), (2) observations converted from intensity to ground motion (or vice versa), and (3) estimated ground motions and intensities from prediction equations or numerical models. Critically, each of the aforementioned data types must include an estimate of its uncertainties, including those caused by scaling the influence of observations to surrounding grid points and those associated with estimates given an unknown fault geometry. The ShakeMap ground-motion and intensity estimates are an uncertainty-weighted combination of these various data and estimates. A natural by-product of this interpolation process is an estimate of total uncertainty at each point on the map, which can be vital for comprehensive inventory loss calculations. We perform a number of tests to validate this new methodology and find that it produces a substantial improvement in the accuracy of ground-motion predictions over empirical prediction equations alone.

  15. State Variation in Medical Imaging: Despite Great Variation, the Medicare Spending Decline Continues.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Hughes, Danny R; Duszak, Richard

    2015-10-01

    The purpose of this study was to assess state-level trends in per beneficiary Medicare spending on medical imaging. Medicare part B 5% research identifiable files from 2004 through 2012 were used to compute national and state-by-state annual average per beneficiary spending on imaging. State-to-state geographic variation and temporal trends were analyzed. National average per beneficiary Medicare part B spending on imaging increased 7.8% annually between 2004 ($350.54) and its peak in 2006 ($405.41) then decreased 4.4% annually between 2006 and 2012 ($298.63). In 2012, annual per beneficiary spending was highest in Florida ($367.25) and New York ($355.67) and lowest in Ohio ($67.08) and Vermont ($72.78). Maximum state-to-state geographic variation increased over time, with the ratio of highest-spending state to lowest-spending state increasing from 4.0 in 2004 to 5.5 in 2012. Spending in nearly all states decreased since peaks in 2005 (six states) or 2006 (43 states). The average annual decrease among states was 5.1% ± 1.8% (range, 1.2-12.2%) The largest decrease was in Ohio. In only two states did per beneficiary spending increase (Maryland, 12.5% average annual increase since 2005; Oregon, 4.8% average annual increase since 2008). Medicare part B average per beneficiary spending on medical imaging declined in nearly every state since 2005 and 2006 peaks, abruptly reversing previously reported trends. Spending continued to increase, however, in Maryland and Oregon. Identification of state-level variation may facilitate future investigation of the potential effect of specific and regional changes in spending on patient access and outcomes.

  16. Effect of background correction on peak detection and quantification in online comprehensive two-dimensional liquid chromatography using diode array detection.

    Science.gov (United States)

    Allen, Robert C; John, Mallory G; Rutan, Sarah C; Filgueira, Marcelo R; Carr, Peter W

    2012-09-07

    A singular value decomposition-based background correction (SVD-BC) technique is proposed for the reduction of background contributions in online comprehensive two-dimensional liquid chromatography (LC×LC) data. The SVD-BC technique was compared to simply subtracting a blank chromatogram from a sample chromatogram and to a previously reported background correction technique for one dimensional chromatography, which uses an asymmetric weighted least squares (AWLS) approach. AWLS was the only background correction technique to completely remove the background artifacts from the samples as evaluated by visual inspection. However, the SVD-BC technique greatly reduced or eliminated the background artifacts as well and preserved the peak intensity better than AWLS. The loss in peak intensity by AWLS resulted in lower peak counts at the detection thresholds established using standards samples. However, the SVD-BC technique was found to introduce noise which led to detection of false peaks at the lower detection thresholds. As a result, the AWLS technique gave more precise peak counts than the SVD-BC technique, particularly at the lower detection thresholds. While the AWLS technique resulted in more consistent percent residual standard deviation values, a statistical improvement in peak quantification after background correction was not found regardless of the background correction technique used. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Solar cycle variations of geocoronal balmer α emission

    International Nuclear Information System (INIS)

    Nossal, S.; Reynolds, R.J.; Roesler, F.L.; Scherb, F.

    1993-01-01

    Observations of the geocoronal Balmer in nightglow have been made from Wisconsin for more than a solar cycle with an internally consistent intensity reference to standard astronomical nebulae. These measurements were made with a double etalon, pressure-scanned, 15-cm aperture Fabry-Perot interferometer. The resulting long time data provides an opportunity to examine solar cycle influence on the mid-latitude exosphere and to address accompanying questions concerning the degree to which the exosphere is locally static or changing. The exospheric Balmer α absolute intensity measurements reported here show no statistically significant variations throughout the solar cycle when the variation with viewing geometry is removed by normalizing the data to reference exospheric model predictions by Anderson et al. However, the relative intensity dependence on solar depression angle does show a solar cycle variation. This variation suggests a possible related variation in the exospheric hydrogen density profile, although other interpretations are also possible. The results suggest that additional well-calibrated data taken over a longer time span could probe low-amplitude variations over the solar cycle and test predictions of a slow monotonic increase in exospheric hydrogen arising from greenhouse gases. 21 refs., 9 figs., 2 tabs

  18. Scenario analysis on the goal of carbon emission peaking around 2030 of China proposed in the China-U.S. joint statement on climate change

    Science.gov (United States)

    Zheng, T.

    2015-12-01

    A goal of carbon (C) emission peaking around 2030 of China was declared in the China-U.S. joint statement on climate change, and emphasized in China's intended nationally determined contributions (INDC). Here, we predicted the carbon emission of China during the period 2011~2050 under seven scenarios, and analyzed the scientific and social implications of realizing the goal. Our results showed that: (1) C emissions of China will reach their peaks at 2022~2045 (with peak values 3.15~5.10 Pg C), and the predicted decay rates of C intensity were 2.1~4.2% in 2011~2050; (2) the precondition that the national C emission reaches the peak before 2030 is that the annual decay rates of C intensity must exceed 3.3% , as decay rates under different scenarios were predicted higher than that except for Past G8 scenario; (3) the national C emission would reach the peak before 2030, if the government of China should realize the C emissions reduction goals of China's 12th five-year plan, climate commitments of Copenhagen and INDC; (4) Chinese government could realize the goal of C emission peaking around 2030 from just controlling C emission intensity , but associated with relatively higher government's burden. In summary, China's C emission may well peak before 2030, meanwhile the combination of emissions reduction and economic macro-control would be demanded to avoid heavier social pressure of C emissions reduction occurred.

  19. Maximal intensity higher-order Akhmediev breathers of the nonlinear Schrödinger equation and their systematic generation

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Siu A., E-mail: chin@physics.tamu.edu [Department of Physics and Astronomy, Texas A& M University, College Station, TX 77843 (United States); Ashour, Omar A. [Department of Physics and Astronomy, Texas A& M University, College Station, TX 77843 (United States); Science Program, Texas A& M University at Qatar, P.O. Box 23874 Doha (Qatar); Nikolić, Stanko N. [Science Program, Texas A& M University at Qatar, P.O. Box 23874 Doha (Qatar); Institute of Physics, University of Belgrade, Pregrevica 118, 11080 Belgrade (Serbia); Belić, Milivoj R. [Science Program, Texas A& M University at Qatar, P.O. Box 23874 Doha (Qatar)

    2016-10-23

    It is well known that Akhmediev breathers of the nonlinear cubic Schrödinger equation can be superposed nonlinearly via the Darboux transformation to yield breathers of higher order. Surprisingly, we find that the peak height of each Akhmediev breather only adds linearly to form the peak height of the final breather. Using this peak-height formula, we show that at any given periodicity, there exists a unique high-order breather of maximal intensity. Moreover, these high-order breathers form a continuous hierarchy, growing in intensity with increasing periodicity. For any such higher-order breather, a simple initial wave function can be extracted from the Darboux transformation to dynamically generate that breather from the nonlinear Schrödinger equation. - Highlights: • Proved an analytical formula for the peak-height of an nth-order Akhmediev breather. • Constructed nth-order Akhmediev breathers of maximal peak intensity. • Extracted initial wave functions that can be used experimentally to produce these maximal breathers in optical fibers.

  20. A Methodological Approach to Quantifying Plyometric Intensity.

    Science.gov (United States)

    Jarvis, Mark M; Graham-Smith, Phil; Comfort, Paul

    2016-09-01

    Jarvis, MM, Graham-Smith, P, and Comfort, P. A Methodological approach to quantifying plyometric intensity. J Strength Cond Res 30(9): 2522-2532, 2016-In contrast to other methods of training, the quantification of plyometric exercise intensity is poorly defined. The purpose of this study was to evaluate the suitability of a range of neuromuscular and mechanical variables to describe the intensity of plyometric exercises. Seven male recreationally active subjects performed a series of 7 plyometric exercises. Neuromuscular activity was measured using surface electromyography (SEMG) at vastus lateralis (VL) and biceps femoris (BF). Surface electromyography data were divided into concentric (CON) and eccentric (ECC) phases of movement. Mechanical output was measured by ground reaction forces and processed to provide peak impact ground reaction force (PF), peak eccentric power (PEP), and impulse (IMP). Statistical analysis was conducted to assess the reliability intraclass correlation coefficient and sensitivity smallest detectable difference of all variables. Mean values of SEMG demonstrate high reliability (r ≥ 0.82), excluding ECC VL during a 40-cm drop jump (r = 0.74). PF, PEP, and IMP demonstrated high reliability (r ≥ 0.85). Statistical power for force variables was excellent (power = 1.0), and good for SEMG (power ≥0.86) excluding CON BF (power = 0.57). There was no significant difference (p > 0.05) in CON SEMG between exercises. Eccentric phase SEMG only distinguished between exercises involving a landing and those that did not (percentage of maximal voluntary isometric contraction [%MVIC] = no landing -65 ± 5, landing -140 ± 8). Peak eccentric power, PF, and IMP all distinguished between exercises. In conclusion, CON neuromuscular activity does not appear to vary when intent is maximal, whereas ECC activity is dependent on the presence of a landing. Force characteristics provide a reliable and sensitive measure enabling precise description of intensity

  1. 4D RECONSTRUCTIONS FROM LOW-COUNT SPECT DATA USING DEFORMABLE MODELS WITH SMOOTH INTERIOR INTENSITY VARIATIONS

    International Nuclear Information System (INIS)

    Cunningham, G. S.; Lehovich, A.

    2000-01-01

    The Bayes Inference Engine (BIE) has been used to perform a 4D reconstruction of a first-pass radiotracer bolus distribution inside a CardioWest Total Artificial Heart, imaged with the University of Arizona's FastSPECT system. The BIE estimates parameter values that define the 3D model of the radiotracer distribution at each of 41 times spanning about two seconds. The 3D models have two components: a closed surface, composed of hi-quadratic Bezier triangular surface patches, that defines the interface between the part of the blood pool that contains radiotracer and the part that contains no radiotracer, and smooth voxel-to-voxel variations in intensity within the closed surface. Ideally, the surface estimates the ventricular wall location where the bolus is infused throughout the part of the blood pool contained by the right ventricle. The voxel-to-voxel variations are needed to model an inhomogeneously-mixed bolus. Maximum a posterior (MAP) estimates of the Bezier control points and voxel values are obtained for each time frame. We show new reconstructions using the Bezier surface models, and discuss estimates of ventricular volume as a function of time, ejection fraction, and wall motion. The computation time for our reconstruction process, which directly estimates complex 3D model parameters from the raw data, is performed in a time that is competitive with more traditional voxel-based methods (ML-EM, e.g.)

  2. Numerical simulations of self-pinched transport of intense ion beams in low-pressure gases

    International Nuclear Information System (INIS)

    Rose, D.V.; Ottinger, P.F.; Welch, D.R.; Oliver, B.V.; Olson, C.L.

    1999-01-01

    The self-pinched transport of intense ion beams in low-pressure background gases is studied using numerical simulations and theoretical analysis. The simulations are carried out in a parameter regime that is similar to proton beam experiments being fielded on the Gamble II pulsed power generator [J. D. Shipman, Jr., IEEE Trans. Nucl. Sci. NS-18, 243 (1971)] at the Naval Research Laboratory. Simulation parameter variations provide information on scaling with background gas species, gas pressure, beam current, beam energy, injection angles, and boundaries. The simulation results compare well with simple analytic scaling arguments for the gas pressure at which the effective net current should peak and with estimates for the required confinement current. The analysis indicates that the self-pinched transport of intense proton beams produced on Gamble II (1.5 MeV, 100 kA, 3 cm radius) is expected to occur at gas pressures between 30 and 80 mTorr of He or between 3 and 10 mTorr of Ar. The significance of these results to ion-driven inertial confinement fusion is discussed. copyright 1999 American Institute of Physics

  3. Climate Change Impacts on Peak Electricity Consumption: US vs. Europe.

    Science.gov (United States)

    Auffhammer, M.

    2016-12-01

    It has been suggested that climate change impacts on the electric sector will account for the majority of global economic damages by the end of the current century and beyond. This finding is at odds with the relatively modest increase in climate driven impacts on consumption. Comprehensive high frequency load balancing authority level data have not been used previously to parameterize the relationship between electric demand and temperature for any major economy. Using statistical models we analyze multi-year data from load balancing authorities in the United States of America and the European Union, which are responsible for more than 90% of the electricity delivered to residential, industrial, commercial and agricultural customers. We couple the estimated response functions between total daily consumption and daily peak load with an ensemble of downscaled GCMs from the CMIP5 archive to simulate climate change driven impacts on both outcomes. We show moderate and highly spatially heterogeneous changes in consumption. The results of our peak load simulations, however, suggest significant changes in the intensity and frequency of peak events throughout the United States and Europe. As the electricity grid is built to endure maximum load, which usually occurs on the hottest day of the year, our findings have significant implications for the construction of costly peak generating and transmission capacity.

  4. Electricity Portfolio Management: Optimal Peak / Off-Peak Allocations

    OpenAIRE

    Huisman, Ronald; Mahieu, Ronald; Schlichter, Felix

    2007-01-01

    textabstractElectricity purchasers manage a portfolio of contracts in order to purchase the expected future electricity consumption profile of a company or a pool of clients. This paper proposes a mean-variance framework to address the concept of structuring the portfolio and focuses on how to allocate optimal positions in peak and off-peak forward contracts. It is shown that the optimal allocations are based on the difference in risk premiums per unit of day-ahead risk as a measure of relati...

  5. Impact of carbon intensity and energy security constraints on China's coal import

    International Nuclear Information System (INIS)

    Lin Boqiang; Liu Jianghua; Yang Yingchun

    2012-01-01

    Logistic and Gaussian Curves are adopted in this article to predict the coal production peak for Shanxi province, Henan province as well as the whole of China. According to the prediction based on the basic coal reserve data, coal production in China will reach its peak in the 2030 s while that of Shanxi and Henan provinces will be achieved by the 2040 s and 2020 s respectively. This article also assesses the influential factors of China's coal peak and revises the forecast of about China's coal demand by taking the CO2 intensity constraint into consideration, and then predicting the corresponding coal import. The results show that China would import 983 million tonnes of coal in 2020; which takes as high as 27% of China's total coal consumption. This article demonstrates that even if China fulfills CO2 intensity constraint, the country's energy situation would still be grim as a result of its high GDP growth rate. Therefore, China has to consider both CO2 intensity and energy security constraints when establishing strategic energy plan. Finally, this article suggests an adjustment of energy structure by which those constraints can be addressed and further assesses the effect of the adjusted energy structure. - Highlights: ► China's coal peak will arrive in 2040s when basic reserve data is used. ► China's peak production would be 4.8–5.8 billion tons. ► The energy security is still grim even if China meets CO 2 intensity constraint. ► The energy structure suggested should be “natural gas in place of oil and coal”.

  6. The influence of cricket fast bowlers' front leg technique on peak ground reaction forces.

    Science.gov (United States)

    Worthington, Peter; King, Mark; Ranson, Craig

    2013-01-01

    High ground reaction forces during the front foot contact phase of the bowling action are believed to be a major contributor to the high prevalence of lumbar stress fractures in fast bowlers. This study aimed to investigate the influence of front leg technique on peak ground reaction forces during the delivery stride. Three-dimensional kinematic data and ground reaction forces during the front foot contact phase were captured for 20 elite male fast bowlers. Eight kinematic parameters were determined for each performance, describing run-up speed and front leg technique, in addition to peak force and time to peak force in the vertical and horizontal directions. There were substantial variations between bowlers in both peak forces (vertical 6.7 ± 1.4 body weights; horizontal (braking) 4.5 ± 0.8 body weights) and times to peak force (vertical 0.03 ± 0.01 s; horizontal 0.03 ± 0.01 s). These differences were found to be linked to the orientation of the front leg at the instant of front foot contact. In particular, a larger plant angle and a heel strike technique were associated with lower peak forces and longer times to peak force during the front foot contact phase, which may help reduce the likelihood of lower back injuries.

  7. River flooding due to intense precipitation

    International Nuclear Information System (INIS)

    Lin, James C.

    2014-01-01

    River stage can rise and cause site flooding due to local intense precipitation (LIP), dam failures, snow melt in conjunction with precipitation or dam failures, etc. As part of the re-evaluation of the design basis as well as the PRA analysis of other external events, the likelihood and consequence of river flooding leading to the site flooding need to be examined more rigorously. To evaluate the effects of intense precipitation on site structures, the site watershed hydrology and pond storage are calculated. To determine if river flooding can cause damage to risk-significant systems, structures, and components (SSC), water surface elevations are analyzed. Typically, the amount and rate of the input water is determined first. For intense precipitation, the fraction of the rainfall in the watershed drainage area not infiltrated into the ground is collected in the river and contributes to the rise of river water elevation. For design basis analysis, the Probable Maximum Flood (PMF) is evaluated using the Probable Maximum Precipitation (PMP) based on the site topography/configuration. The peak runoff flow rate and water surface elevations resulting from the precipitation induced flooding can then be estimated. The runoff flow hydrograph and peak discharge flows can be developed using the synthetic hydrograph method. The standard step method can then be used to determine the water surface elevations along the river channel. Thus, the flood water from the local intense precipitation storm and excess runoff from the nearby river can be evaluated to calculate the water surface elevations, which can be compared with the station grade floor elevation to determine the effects of site flooding on risk-significant SSCs. The analysis needs to consider any possible diversion flow and the effects of changes to the site configurations. Typically, the analysis is performed based on conservative peak rainfall intensity and the assumptions of failure of the site drainage facilities

  8. Peak regulation right

    International Nuclear Information System (INIS)

    Gao, Z. |; Ren, Z.; Li, Z.; Zhu, R.

    2005-01-01

    A peak regulation right concept and corresponding transaction mechanism for an electricity market was presented. The market was based on a power pool and independent system operator (ISO) model. Peak regulation right (PRR) was defined as a downward regulation capacity purchase option which allowed PRR owners to buy certain quantities of peak regulation capacity (PRC) at a specific price during a specified period from suppliers. The PRR owner also had the right to decide whether or not they would buy PRC from suppliers. It was the power pool's responsibility to provide competitive and fair peak regulation trading markets to participants. The introduction of PRR allowed for unit capacity regulation. The PRR and PRC were rated by the supplier, and transactions proceeded through a bidding process. PRR suppliers obtained profits by selling PRR and PRC, and obtained downward regulation fees regardless of whether purchases are made. It was concluded that the peak regulation mechanism reduced the total cost of the generating system and increased the social surplus. 6 refs., 1 tab., 3 figs

  9. WaVPeak: Picking NMR peaks through wavelet-based smoothing and volume-based filtering

    KAUST Repository

    Liu, Zhi

    2012-02-10

    Motivation: Nuclear magnetic resonance (NMR) has been widely used as a powerful tool to determine the 3D structures of proteins in vivo. However, the post-spectra processing stage of NMR structure determination usually involves a tremendous amount of time and expert knowledge, which includes peak picking, chemical shift assignment and structure calculation steps. Detecting accurate peaks from the NMR spectra is a prerequisite for all following steps, and thus remains a key problem in automatic NMR structure determination. Results: We introduce WaVPeak, a fully automatic peak detection method. WaVPeak first smoothes the given NMR spectrum by wavelets. The peaks are then identified as the local maxima. The false positive peaks are filtered out efficiently by considering the volume of the peaks. WaVPeak has two major advantages over the state-of-the-art peak-picking methods. First, through wavelet-based smoothing, WaVPeak does not eliminate any data point in the spectra. Therefore, WaVPeak is able to detect weak peaks that are embedded in the noise level. NMR spectroscopists need the most help isolating these weak peaks. Second, WaVPeak estimates the volume of the peaks to filter the false positives. This is more reliable than intensity-based filters that are widely used in existing methods. We evaluate the performance of WaVPeak on the benchmark set proposed by PICKY (Alipanahi et al., 2009), one of the most accurate methods in the literature. The dataset comprises 32 2D and 3D spectra from eight different proteins. Experimental results demonstrate that WaVPeak achieves an average of 96%, 91%, 88%, 76% and 85% recall on 15N-HSQC, HNCO, HNCA, HNCACB and CBCA(CO)NH, respectively. When the same number of peaks are considered, WaVPeak significantly outperforms PICKY. The Author(s) 2012. Published by Oxford University Press.

  10. Low-intensity training increases peak arm VO2 by enhancing both convective and diffusive O2 delivery

    DEFF Research Database (Denmark)

    Boushel, R; Ara, I; Gnaiger, E

    2014-01-01

    in prolonged low-intensity training of a small muscle group when the cardiac output capacity is not directly limiting. The purpose of this study was to investigate the relative roles of circulatory and muscle metabolic mechanisms by which prolonged low-intensity exercise training alters regional muscle VO2 ....

  11. The peak altitude of H3+ auroral emission: comparison with the ultraviolet

    Science.gov (United States)

    Blake, J.; Stallard, T.; Miller, S.; Melin, H.; O'Donoghue, J.; Baines, K.

    2013-09-01

    account for this, the acceptable error in misalignment was set to be ± 4 degrees. The accepted error range for the altitudinal profiles was set to ± 250 km. It was determined that variations in the measured altitude of the aurorae are predominantly shifted by misalignment, though there is also some natural variation. Using a second order polynomial fit, the altitude with zero misalignment is measured at 1215 ± 119 km. Further still, through comparison of the IR and UV altitudinal emission profiles is had been discovered that regardless of the alignment, the Infrared auroral altitudinal profile drops off in intensity much faster and the Ultraviolet counterpart, declining to less than 10% of maximum intensity before reaching an altitude of 2000 km above the 1 bar pressure surface. Further work is currently underway to investigate the implication for the emissive behaviour of H3 + with altitude.

  12. Multilayered samples reconstructed by measuring Kα/Kβ or Lα/Lβ X-ray intensity ratios by EDXRF

    Science.gov (United States)

    Cesareo, Roberto; de Assis, Joaquim T.; Roldán, Clodoaldo; Bustamante, Angel D.; Brunetti, Antonio; Schiavon, Nick

    2013-10-01

    In this paper a general method based on energy-dispersive X-ray fluorescence (EDXRF) analysis has been tested to assess its possible use as a tool to reconstruct the structure and determine the thickness of two and/or multi-layered materials. The method utilizes the X-ray intensity ratios of Kα/Kβ or Lα/Lβ peaks (or the ratio of these peaks) for selected elements present in multi-layered objects of various materials (Au alloys, gilded Cu, gilded Ag, gilded Pb, Ag-Au Tumbaga, stone surfaces with protective treatments, Zn or Nickel plating on metals). Results show that, in the case of multi-layered samples, a correct calculation of the peak ratio (Kα /Kβ and/or Lα/Lβ) of relevant elements from energy-dispersive X-ray fluorescence spectra, can provide important information in assessing the exact location of each layer and for calculating its thickness. The methodological approach shown may have important applications not only in materials science but also when dealing with the conservation and restoration of multi-layered cultural heritage objects where the use of a Non-Destructive techniques to determine slight chemical and thickness variations in the layered structure is often of paramount importance to achieve the best results.

  13. Sulphur mountain: Cosmic ray intensity records

    International Nuclear Information System (INIS)

    Venkatesan, D.; Mathews, T.

    1985-01-01

    This book deals with the comic ray intensity registrations at the Sulphur Mountain Cosmic Ray Laboratory. The time series of intensity form a valuable data-set, for studying cosmic ray intensity variations and their dependence on solar activity. The IGY neutron monitor started operating from July 1, 1957 and continued through 1963. Daily mean values are tabulated for the period and these are also represented in plots. This monitor was set up by the National Research Council of Canada

  14. Peak creation in the energy spectrum of laser-produced protons by phase rotation

    International Nuclear Information System (INIS)

    Noda, Akira; Nakamura, Shu; Iwashita, Yoshihisa; Shirai, Toshiyuki; Tongu, Hiromu; Ito, Hiroyuki; Souda, Hikaru; Yamazaki, Atsushi; Tanabe, Mikio; Daido, Hiroyuki; Mori, Michiaki; Kado, Masataka; Sagisaka, Akito; Ogura, Koichi; Nishiuchi, Mamiko; Orimo, Satoshi; Hayashi, Yukio; Yogo, Akifumi; Bulanov, Sergei; Esirkepov, Timur; Nagashima, Akira; Kimura, Toyoaki; Tajima, Toshiki; Fukumi, Atsushi; Li, Zhong

    2007-01-01

    In collaboration between JAEA, Kansai Photon Science Institute and Institute for Chemical Research, Kyoto University, proton generation from a thin foil target (Ti 3 or 5 μm in thickness) with use of 10 TW laser (JLITEX) has been performed. Proton production is optimized by real time proton energy measurement with use of TOF method. Phase rotation with use of an RF electric field phase-synchronized to the pulse laser enabled the creation of peaks with the spread of ∼7% in the energy spectrum of the produced protons, which resulted in the increase of the intensity ∼4 times at peak position. (author)

  15. Periodic permanent magnet focusing system with high peak field

    International Nuclear Information System (INIS)

    Zhang Hong; Liu Weiwei; Bai Shuxin; Chen Ke

    2008-01-01

    In this study, hybrid periodic permanent magnet (PPM) system is studied, which has high axial magnetic field and low magnetic leakage. By simulation computation, some laws of magnetic field distribution vs. structure dimensions were obtained. A hybrid PPM is designed and constructed whose peak field reaches 0.6 T. The factors inducing discrepancies between computational results and practical measurements are analyzed. The magnetic field distribution is very sensitive to the variations of constructional parameters. Construction accuracy greatly influences the magnetic field distribution. Research results obtained here are potentially valuable for future work

  16. The hydrological behaviour of extensive and intensive green roofs in a dry climate.

    Science.gov (United States)

    Razzaghmanesh, M; Beecham, S

    2014-11-15

    This paper presents the results of a hydrological investigation of four medium scale green roofs that were set up at the University of South Australia. In this study, the potential of green roofs as a source control device was investigated over a 2 year period using four medium size green roof beds comprised of two growth media types and two media depths. During the term of this study, 226 rainfall events were recorded and these were representative of the Adelaide climate. In general, there were no statistically significant differences between the rainfall and runoff parameters for the intensive and extensive beds except for peak attenuation and peak runoff delay, for which higher values were recorded in the intensive beds. Longer dry periods generally resulted in higher retention coefficients and higher retention was also recorded in warmer seasons. The average retention coefficient for intensive systems (89%) was higher than for extensive systems (74%). It was shown that rainfall depth, intensity, duration and also average dry weather period between events can change the retention performance and runoff volume of the green roofs. Comparison of green and simulated conventional roofs indicated that the former were able to mitigate the peak of runoff and could delay the start of runoff. These characteristics are important for most source control measures. The recorded rainfall and runoff data displayed a non-linear relationship. Also, the results indicated that continuous time series modelling would be a more appropriate technique than using peak rainfall intensity methods for green roof design and simulation. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. The economic impact of emission peaking control policies and China's sustainable development

    Directory of Open Access Journals (Sweden)

    Yi Wang

    2014-12-01

    Full Text Available To achieve the goals of national sustainable development, the peaking control of CO2 emissions is pivotal, as well as other pollutants. In this paper, we build a Chinese inter-regional CGE model and simulate 13 policies and their combinations. By analyzing the energy consumptions, coal consumptions, relating emissions and their impacts on GDP, we found that with the structure adjustment policy, the proportion of coal in primary fossil fuels in 2030 will decrease from 53% to 48% and CO2 emissions will decrease by 11.3%–22.8% compared to the baseline scenario. With the energy intensity reduction policy, CO2 emissions will decrease by 33.3% in 2030 and 47.8% in 2050 than baseline scenario. Other pollutants will also be controlled as synergetic effects. In this study we also find that although the earlier the peaking time the better for emission amounts control, the economic costs can not be ignored. The GDP will decrease by 2.96%–8.23% under different scenarios. Therefore, integrated policy solutions are needed for realizing the peaks package and more targeted measures are required to achieve the peaks of other pollutants earlier.

  18. Intensive Exercise Training During Bed Rest Attenuates Deconditioning

    Science.gov (United States)

    Greenleaf, John E.

    1997-01-01

    Intensive exercise training during bed rest attenuates deconditioning. Med. Sci. Sports Exerc., Vol. 29, No. 2, pp. 207-215, 1997. A 30-d 6 deg head-down bed rest project was conducted to evaluate variable high-intensity, short-duration, isotonic cycle ergometer exercise (ITE) training and high-intensity intermittent resistive isokinetic exercise (IKE) training regimens designed to maintain peak VO2 and muscle mass, strength, and endurance at ambulatory control levels throughout prolonged bed rest. Other elements of the deconditioning (adaptive) syndrome, such as proprioception, psychological performance, hypovolemia, water balance, body composition, and orthostatic tolerance, were also measured. Major findings are summarized in this paper. Compared with response during bed rest of the no exercise (NOE) control group: the ITE training regimen (a) maintained work capacity (peak VO2), (b) maintained plasma and red cell volumes, (c) induced positive body water balance, (d) decreased quality of sleep and mental concentration, and (e) had no effect on the decrease in orthostatic tolerance; the IKE training regimen (f) attenuated the decrease in peak VO2 by 50%, (g) attenuated loss of red cell volume by 40% but had no effect on loss of plasma volume, (b) induced positive body water balance, (i) had no adverse effect on quality of sleep or concentration, and 0) had no effect on the decrease in orthostatic tolerance. These findings suggest that various elements of the deconditioning syndrome can be manipulated by duration and intensity of ITE or IKE training regimens and that several different training protocols will be required to maintain or restore physiological and psychological performance of individuals confined to prolonged bed rest.

  19. Variation of Raman spectra of CdSe/ZnS quantum dots at the bioconjugation

    Energy Technology Data Exchange (ETDEWEB)

    Macotela, L.G.V.; Douda, J. [UPIITA - Instituto Politecnico Nacional, Mexico (Mexico); Torchynska, T.V. [ESFM - Instituto Politecnico Nacional, Mexico (Mexico); Sierra, R.P. [CINVESTAV del IPN, Mexico (Mexico)

    2010-04-15

    This paper presents the results of comparative analysis of Raman scattering spectra of CdSe/ZnS QDs covered by polymer with and without bio-conjugation to the mouse anti PSA (Prostate-Specific Antigen) antibodies (mab). Commercial CdSe/ZnS QDs used in the study are characterized by the color emission with the maximum at 565 nm (2.19 eV) at 300 K. Raman scattering spectra measured at room temperature demonstrate two groups of peaks: (i) related to the Si substrate at 230-460, 522, 610, 670, 940-1040 cm{sup -1} and (2) to polymer on the QD surface in the spectral range 1268-3310 cm{sup -1}. It is revealed that the QD bio-conjugation to the anti PSA mab is accompanied by the variation dramatically in the intensity of Raman lines of both types. The explanation of Raman peak stimulation in bio-conjugated QDs has been proposed on the base of surface enhanced Raman scattering (SERS) effect (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  20. Origin of absorption peaks in reflection loss spectrum in Ku- frequency band of Co-Zr substituted strontium hexaferrites prepared using sucrose precursor

    Energy Technology Data Exchange (ETDEWEB)

    Narang, Sukhleen Bindra, E-mail: sukhleen2@yahoo.com [Department of Electronics Technology, Guru Nanak Dev University, Amritsar (India); Pubby, Kunal, E-mail: kunalpubby02@gmail.com [Department of Electronics Technology, Guru Nanak Dev University, Amritsar (India); Chawla, S.K., E-mail: sschawla118@gmail.com [Department of Chemistry, Centre for Advanced Studies-I, Guru Nanak Dev University, Amritsar (India); Kaur, Prabhjyot, E-mail: prabhjyot.2525@gmail.com [Department of Chemistry, Centre for Advanced Studies-I, Guru Nanak Dev University, Amritsar (India)

    2017-03-15

    This study presents the detailed explanation of the factors, contributing towards the absorption peaks in reflection loss spectrum of hexaferrites. Cobalt-Zirconium substituted strontium hexaferrites, synthesized using sucrose precursor sol-gel technique, were analyzed in 12.4–18 GHz frequency range. The concepts of impedance matching through quarter wavelength condition, complex thickness, dielectric phase angle and attenuation constant have been used to determine the location as well as intensity of absorption peaks. This study also demonstrates the potential application of three compositions of this series with doping content (x)==0.0, 0.6 and 0.8 as an effective microwave absorbers in Ku-frequency band. - Highlights: • EM analysis of Sr Hexaferrites in Ku-band. • Factors towards absorption peak intensity & location.

  1. Limitation of peak fitting and peak shape methods for determination of activation energy of thermoluminescence glow peaks

    CERN Document Server

    Sunta, C M; Piters, T M; Watanabe, S

    1999-01-01

    This paper shows the limitation of general order peak fitting and peak shape methods for determining the activation energy of the thermoluminescence glow peaks in the cases in which retrapping probability is much higher than the recombination probability and the traps are filled up to near saturation level. Right values can be obtained when the trap occupancy is reduced by using small doses or by post-irradiation partial bleaching. This limitation in the application of these methods has not been indicated earlier. In view of the unknown nature of kinetics in the experimental samples, it is recommended that these methods of activation energy determination should be applied only at doses well below the saturation dose.

  2. Thermoluminescence of SrAl_2O_4:Eu"2"+, Dy"3"+: dosimetric characteristics and evidence of glow-peak collocation

    International Nuclear Information System (INIS)

    Chithambo, M.L.

    2016-01-01

    The thermoluminescence of SrAl_2O_4:Eu"2"+, Dy"3"+ consists of collocated peaks whereby a dominant component subsumes subsidiary ones to such an extent that they appear as one; Qualitative and quantitative analysis of such cases will be described with suitable illustrative examples. The general features and qualitative kinetics properties of thermoluminescence from SrAl_2O_4:Eu"2"+, Dy"3"+ is reported. Measurements using X-ray excited optical luminescence show that stimulated luminescence from SrAl_2O_4:Eu"2"+, Dy"3"+ has two prominent emission bands, one at 475 nm and a more intense one near 575 nm, studied in this work. There are also weaker intensity emissions at 405, 510, 600 and 660 nm. The natural thermoluminescence measured at 1°C s"-"1 shows three peaks at 74, 170 and 340°C whereas 20 Gy beta-irradiation produces TL dominated by a single peak at 34°C. Analysis of this peak for its order of kinetics produces somewhat inconclusive results. The results of the partial heating procedure T_m - T_s_t_o_p are consistent with both first and second-order kinetics. On the other hand, the position of the peak is independent of dose for several ranges of doses implying that the apparently single peak consists of multiple first-order peaks. Complementary investigations using the fractional glow technique, resolution by isothermal heating and the effect of fading on the peak show that the glow-curve of SrAl_2O_4:Eu"2"+, Dy"3"+ comprises closely collocated thermoluminescence peaks. The implication of such complexity on kinetic analysis on this material and others that share this feature will be discussed. (author)

  3. Make peak flow a habit

    Science.gov (United States)

    Asthma - make peak flow a habit; Reactive airway disease - peak flow; Bronchial asthma - peak flow ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  4. Electrophysiological Correlates of Changes in Reaction Time Based on Stimulus Intensity

    Science.gov (United States)

    Lakhani, Bimal; Vette, Albert H.; Mansfield, Avril; Miyasike-daSilva, Veronica; McIlroy, William E.

    2012-01-01

    Background Although reaction time is commonly used as an indicator of central nervous system integrity, little is currently understood about the mechanisms that determine processing time. In the current study, we are interested in determining the differences in electrophysiological events associated with significant changes in reaction time that could be elicited by changes in stimulus intensity. The primary objective is to assess the effect of increasing stimulus intensity on the latency and amplitude of afferent inputs to the somatosensory cortex, and their relation to reaction time. Methods Median nerve stimulation was applied to the non-dominant hand of 12 healthy young adults at two different stimulus intensities (HIGH & LOW). Participants were asked to either press a button as fast as possible with their dominant hand or remain quiet following the stimulus. Electroencephalography was used to measure somatosensory evoked potentials (SEPs) and event related potentials (ERPs). Electromyography from the flexor digitorum superficialis of the button-pressing hand was used to assess reaction time. Response time was the time of button press. Results Reaction time and response time were significantly shorter following the HIGH intensity stimulus compared to the LOW intensity stimulus. There were no differences in SEP (N20 & P24) peak latencies and peak-to-peak amplitude for the two stimulus intensities. ERPs, locked to response time, demonstrated a significantly larger pre-movement negativity to positivity following the HIGH intensity stimulus over the Cz electrode. Discussion This work demonstrates that rapid reaction times are not attributable to the latency of afferent processing from the stimulated site to the somatosensory cortex, and those latency reductions occur further along the sensorimotor transformation pathway. Evidence from ERPs indicates that frontal planning areas such as the supplementary motor area may play a role in transforming the elevated sensory

  5. Oxidative stress does not influence local sweat rate during high-intensity exercise.

    Science.gov (United States)

    Meade, Robert D; Fujii, Naoto; Poirier, Martin P; Boulay, Pierre; Sigal, Ronald J; Kenny, Glen P

    2018-02-01

    What is the central question of this study? We evaluated whether oxidative stress attenuates the contribution of nitric oxide to sweating during high-intensity exercise. What is the main finding and its importance? In contrast to our previous report of an oxidative stress-mediated reduction in nitric oxide-dependent cutaneous vasodilatation in this cohort during intense exercise, we demonstrated no influence of local ascorbate administration on the sweating response during moderate- (∼51% peak oxygen uptake) or high-intensity exercise (∼72% peak oxygen uptake). These new findings provide important mechanistic insight into how exercise-induced oxidative stress impacts sudomotor activity. Nitric oxide (NO)-dependent sweating is diminished during high- but not moderate-intensity exercise. We evaluated whether this impairment stems from increased oxidative stress during high-intensity exercise. On two separate days, 11 young (24 ± 4 years) men cycled in the heat (35°C) at a moderate [500 W; 52 ± 6% peak oxygen uptake (V̇O2 peak )] or high (700 W; 71 ± 5% V̇O2 peak ) rate of metabolic heat production. Each session included two 30 min exercise bouts separated by a 20 min recovery period. Local sweat rate was monitored at four forearm skin sites continuously perfused via intradermal microdialysis with the following: (i) lactated Ringer solution (Control); (ii) 10 mm ascorbate (Ascorbate; non-selective antioxidant); (iii) 10 mm N G -nitro-l-arginine methyl ester (l-NAME; NO synthase inhibitor); or (iv) 10 mm ascorbate plus 10 mm l-NAME (Ascorbate + l-NAME). During moderate exercise, sweat rate was attenuated at the l-NAME and Ascorbate + l-NAME sites (both ∼1.0 mg min -1  cm -2 ; all P < 0.05) but not at the Ascorbate site (∼1.1 mg min -1  cm -2 ; both P ≥ 0.28) in comparison to the Control site (∼1.1 mg min -1  cm -2 ). However, no differences were observed between treatment sites (∼1.4 mg min -1  cm -2 ; P = 0

  6. Variations in the small-scale galactic magnetic field and short time-scale intensity variations of extragalactic radio sources

    International Nuclear Information System (INIS)

    Simonetti, J.H.

    1985-01-01

    Structure functions of the Faraday rotation measures (RMs) of extragalactic radio sources are used to investigate variations in the interstellar magnetic field on length scales of approx.0.01 to 100 pc. Model structure functions derived assuming a power-law power spectrum of irregularities in n/sub e/B, are compared with those observed. The results indicate an outer angular scale for RM variations of approximately less than or equal to 5 0 and evidence for RM variations on scales as small as 1'. Differences in the variance of n/sub e/B fluctuations for various lines of sight through the Galaxy are found. Comparison of pulsar scintillations in right- and left-circular polarizations yield an upper limit to the variations in n/sub e/ on a length scale of approx.10 11 cm. RMs were determined through high-velocity molecular flows in galactic star-formation regions, with the goal of constraining magnetic fields in and near the flows. RMs of 7 extragalactic sources with a approx.20 arcmin wide area seen through Cep A, fall in two groups separated by approx.150 rad m -2 - large given our knowledge of RM variations on small angular scales and possibly a result of the anisotropy of the high-velocity material

  7. Comparison of respiratory-induced variations in photoplethysmographic signals

    International Nuclear Information System (INIS)

    Li, Jin; Jin, Jie; Chen, Xiang; Sun, Weixin; Guo, Ping

    2010-01-01

    Photoplethysmography (PPG) is an optical method for detecting blood volume changes in tissue. Respiratory-induced intensity, frequency and amplitude variations are contained in the PPG signal; thus, an understanding of the relationships between all of these variations and respiration is essential to advancing respiration monitoring based on PPG. This study investigated correlations between respiratory-induced variations extracted from PPG and simultaneous respiratory signals. PPG signals were recorded from 28 healthy subjects under eight different conditions. Six respiratory-induced variations, i.e. the period of the systole, diastole and pulse, the amplitude of the systole and diastole, and the intensity variation, were determined from the PPG signal. The results indicate that, compared with the period of the pulse, the period of the systole and diastole correlates weakly with respiration; the amplitude of the diastole has a stronger correlation with respiration than the amplitude of the systole. For men, when the respiratory rate is less than 10 breaths min −1 , the period of the pulse has the strongest correlation with respiration, whereas up to or above 15 breaths min −1 , the intensity variation becomes strongest in the sitting posture, while the amplitude of the diastole is strongest in the supine posture. For women, compared with the other variations, the period of the pulse has nearly the strongest correlation with respiration, independent of respiratory rate or posture

  8. Regional variations in health care intensity and physician perceptions of quality of care.

    Science.gov (United States)

    Sirovich, Brenda E; Gottlieb, Daniel J; Welch, H Gilbert; Fisher, Elliott S

    2006-05-02

    Research has documented dramatic differences in health care utilization and spending across U.S. regions with similar levels of patient illness. Although patient outcomes and quality of care have been found to be no better in regions of high health care intensity, it is unknown whether physicians in these regions feel more capable of providing good patient care than those in low-intensity regions. To determine whether physicians in high-intensity regions feel better able to care for patients than physicians in low-intensity regions. Physician telephone survey. 51 metropolitan and 9 nonmetropolitan areas of the United States and a supplemental national sample. 10,577 physicians who provided care to adults in 1998 or 1999 were surveyed for the Community Tracking Study (response rate, 61%). The End-of-Life Expenditure Index, a measure of spending that reflects differences in the overall quantity of medical services provided rather than differences in illness or price, was used to determine health care intensity in the physicians' community. Outcomes included physicians' perceived availability of clinical services, ability to provide high-quality care to patients, and career satisfaction. Although the highest-intensity regions have substantially more hospital beds and specialists per capita, physicians in these regions reported more difficulty obtaining needed services for their patients. The proportion of physicians who felt able to obtain elective hospital admissions ranged from 50% in high-intensity regions to 64% in the lowest-intensity region (P market factors (for example, managed care penetration); the difference in perceived ability to provide high-quality care was no longer statistically significant (P = 0.099). The cross-sectional design prevented demonstration of a causal relationship between intensity and physician perceptions of quality. Despite more resources, physicians in regions of high health care intensity did not report greater ease in obtaining

  9. Dependence of ionospheric response on the local time of sudden commencement and the intensity of geomagnetic storms

    International Nuclear Information System (INIS)

    Balan, N.; Rao, P.B.

    1990-01-01

    A study has been designed specifically to investigate the dependence of the ionospheric response on the time of occurrence of sudden commencement (SC) and the intensity of the magnetic storms for a low- and a mid-latitude station by considering total electron content and peak electron density data for more than 60 SC-type geomagnetic storms. The nature of the response, whether positive or negative, is found to be determined largely by the local time of SC, although there is a local time shift of about six hours between low- and mid-latitudes. The time delays associated with the positive responses are low for daytime SCs and high for night-time SCs, whereas the opposite applies for negative responses. The time delays are significantly shorter for mid-latitudes than for low-latitudes and, at both latitudes, are inversely related to the intensity of the storm. There is a positive correlation between the intensity of the ionospheric response and that of the magnetic storm, the correlation being greater at mid-latitudes. The results are discussed in the light of the possible processes which might contribute to the storm-associated ionospheric variations. (author)

  10. Intense ion beam generator

    International Nuclear Information System (INIS)

    Humphries, S. Jr.; Sudan, R.N.

    1977-01-01

    Methods and apparatus for producing intense megavolt ion beams are disclosed. In one embodiment, a reflex triode-type pulsed ion accelerator is described which produces ion pulses of more than 5 kiloamperes current with a peak energy of 3 MeV. In other embodiments, the device is constructed so as to focus the beam of ions for high concentration and ease of extraction, and magnetic insulation is provided to increase the efficiency of operation

  11. The Circadian Variation of Psychophysiological Reactivity to Stress : A Study of Individual Differences

    Science.gov (United States)

    1994-08-25

    and/ or peak during the morning hours (Millar- Craig , Bishop, and Raftery, 1978; Turton and Deegan , 1974; and Weitzman et al., 1971). Furthermore, a...hematological factors showing distinct c i rcadian variations (e.g. Millar- Craig , Bishop, and Raftery, 1978; Weitzman, Fukushima, Nogeire, Roffwarg...examined the circadian variation o f blood pressure (BP), and have observed a morning peak in blood pressure (e.g., Millar- Craig , Bishop, & Raftery

  12. Intensity limits for stationary and interacting multi-soliton complexes

    International Nuclear Information System (INIS)

    Sukhorukov, Andrey A.; Akhmediev, Nail N.

    2002-01-01

    We obtain an accurate estimate for the peak intensities of multi-soliton complexes for a Kerr-type nonlinearity in the (1+1) dimension problem. Using exact analytical solutions of the integrable set of nonlinear Schroedinger equations, we establish a rigorous relationship between the eigenvalues of incoherently-coupled fundamental solitons and the range of admissible intensities. A clear geometrical interpretation of this effect is given

  13. THz Induced Nonlinear Effects in Materials at Intensities above 26 GW/cm2

    Science.gov (United States)

    Woldegeorgis, A.; Kurihara, T.; Beleites, B.; Bossert, J.; Grosse, R.; Paulus, G. G.; Ronneberger, F.; Gopal, A.

    2018-04-01

    Nonlinear refractive index and absorption coefficient are measured for common semiconductor material such as silicon and organic molecule such as lactose in the terahertz (THz) spectral regime extending from 0.1 to 3 THz. Terahertz pulses with field strengths in excess of 4.4 MV/cm have been employed. Transmittance and the transmitted spectrum were measured with Z-scan and single shot noncollinear electro-optic pump-probe techniques. The THz-induced change in the refractive index (Δn) shows frequency-dependence and a maximum change of - 0.128 at 1.37 THz in lactose and up to + 0.169 at 0.15 THz in silicon was measured for a peak incident THz intensity of 26 GW/cm2. Furthermore, the refractive index variation shows a quadratic dependence on the incident THz field, implying the dominance of third-order nonlinearity.

  14. Intensive Care Unit Structure Variation and Implications for Early Mobilization Practices. An International Survey.

    Science.gov (United States)

    Bakhru, Rita N; McWilliams, David J; Wiebe, Douglas J; Spuhler, Vicki J; Schweickert, William D

    2016-09-01

    Early mobilization (EM) improves outcomes for mechanically ventilated patients. Variation in structure and organizational characteristics may affect implementation of EM practices. We queried intensive care unit (ICU) environment and standardized ICU practices to evaluate organizational characteristics that enable EM practice. We recruited 151 ICUs in France, 150 in Germany, 150 in the United Kingdom, and 500 in the United States by telephone. Survey domains included respondent characteristics, hospital and ICU characteristics, and ICU practices and protocols. We surveyed 1,484 ICU leaders and received a 64% response rate (951 ICUs). Eighty-eight percent of respondents were in nursing leadership roles; the remainder were physiotherapists. Surveyed ICUs were predominantly mixed medical-surgical units (67%), and 27% were medical ICUs. ICU staffing models differed significantly (P equipment were highly variable among respondents. International ICU structure and practice is quite heterogeneous, and several factors (multidisciplinary rounds, setting daily goals for patients, presence of a dedicated physiotherapist, country, and nurse/patient staffing ratio) are significantly associated with the practice of EM. Practice and barriers may be far different based upon staffing structure. To achieve successful implementation, whether through trials or quality improvement, ICU staffing and practice patterns must be taken into account.

  15. Prediction of SEP Peak Proton Intensity Based on CME Speed, Direction and Observations of Associated Solar Phenomena

    Science.gov (United States)

    Richardson, I. G.; Mays, M. L.; Thompson, B. J.; Kwon, R.; Frechette, B. P.

    2017-12-01

    We assess whether a formula obtained by Richardson et al. (Solar Phys., 289, 3059, 2014; DOI 10.1007/s11207-014-0524-8) relating the intensity of 14-24 MeV protons in a solar energetic particle event at 1 AU to the solar event location and the speed of the associated coronal mass ejection (CME), may be used to "predict" the intensity of a solar energetic particle event. Starting with a subset of several hundred CMEs in the CCMC/SWRC DONKI real-time database (http://kauai.ccmc.gsfc.nasa.gov/DONKI/) selected without consideration of whether they were associated with SEP events, we first use the CME speed and direction to predict the proton intensity at Earth or the STEREO spacecraft using this formula. Since most of these CMEs were not in fact associated with SEP events, many "false alarms" result. We then examine whether considering other phenomena which may accompany the CMEs, such as the X-ray flare intensity and the properties of type II and type III radio emissions, may help to reduce the false alarm rate. We also use CME parameters calculated from an ellipsoidal shell fit to multi-spacecraft CME shock observations for a smaller number of events to predict the SEP intensity. We calculate skill scores for each case and assess whether the Richardson et al. (2014) formula, using additional observations to reduce the false alarm rate, has any potential as a SEP prediction tool, assuming that the required observations could be acquired sufficiently rapidly following the onset of the related solar event/CME.

  16. The influence of high-intensity compared with moderate-intensity exercise training on cardiorespiratory fitness and body composition in colorectal cancer survivors: a randomised controlled trial.

    Science.gov (United States)

    Devin, James L; Sax, Andrew T; Hughes, Gareth I; Jenkins, David G; Aitken, Joanne F; Chambers, Suzanne K; Dunn, Jeffrey C; Bolam, Kate A; Skinner, Tina L

    2016-06-01

    Following colorectal cancer diagnosis and anti-cancer therapy, declines in cardiorespiratory fitness and body composition lead to significant increases in morbidity and mortality. There is increasing interest within the field of exercise oncology surrounding potential strategies to remediate these adverse outcomes. This study compared 4 weeks of moderate-intensity exercise (MIE) and high-intensity exercise (HIE) training on peak oxygen consumption (V̇O2peak) and body composition in colorectal cancer survivors. Forty seven post-treatment colorectal cancer survivors (HIE = 27 months post-treatment; MIE = 38 months post-treatment) were randomised to either HIE [85-95 % peak heart rate (HRpeak)] or MIE (70 % HRpeak) in equivalence with current physical activity guidelines and completed 12 training sessions over 4 weeks. HIE was superior to MIE in improving absolute (p = 0.016) and relative (p = 0.021) V̇O2peak. Absolute (+0.28 L.min(-1), p body composition for colorectal cancer survivors. HIE appears to offer superior improvements in cardiorespiratory fitness and body composition in comparison to current physical activity recommendations for colorectal cancer survivors and therefore may be an effective clinical utility following treatment.

  17. Estimation of cerium and lanthanum content in core material of high intensity carbon arc electrodes by x-ray fluorescence method

    International Nuclear Information System (INIS)

    Nagpal, K.C.; Bhavalkar, R.H.

    1977-01-01

    The X-ray fluorescence method has been used to determine the weight percentages of cerium and lanthanum in the core material of high intensity carbon arc electrodes from the calibration curves plotted between the weight percentages of these elements and the peak-intensity ratios of CeLsub(α1), and LaLsub(α1) peaks to the neighbouring peak SnLsub(α1) due to an internal standard element. (author)

  18. Estimation of historical earthquake intensities and intensity-PGA relationship for wooden house damages

    International Nuclear Information System (INIS)

    Choi, In-Kil; Seo, Jeong-Moon

    2002-01-01

    A series of tests and dynamic analyses on Korean traditional wooden houses was performed for the intensity estimation of the typical large historical earthquake records. Static and cyclic lateral load tests on the wooden frames were performed to assess the lateral load capacity of wooden frames. The shaking table tests on two 1:4 scaled models of a Korean ancient commoner's house made of fresh pine lumber were performed. Typical earthquake time histories recorded on soil and rock sites were used as input for the tests. The prototypical wooden house was analyzed for multiple time histories which match Ohsaki's ground response spectra. Seismic analyses comprise the aging of lumber and different soil condition. The relationship between the earthquake intensity and the peak ground acceleration (PGA) is proposed for the wooden house damages based on the results of this study. The intensity of major Korean historical earthquake records related with house collapses was quantitatively estimated to be MM VIII

  19. Diel and seasonal variation in food habits of Atlantic salmon parr in a small stream

    Science.gov (United States)

    Grader, M.; Letcher, B.H.

    2006-01-01

    The diel and seasonal food habits of young-of-year (YOY) and post-young-of-year (PYOY) Atlantic salmon (Salmo salar) parr were assayed over the course of 11 months in the West Brook, Massachusetts USA. Gut fullness of YOY salmon did not vary significantly among months. PYOY salmon exhibited significant seasonal differences in gut fullness, with peak fullness occurring in the spring and late fall. Significant diel differences in PYOY gut fullness occurred in June and April, with peak fullness always occurring at dawn. Prey composition varied substantially among months. Dominant prey items of PYOY salmon were baetid mayflies in June, July, and August, limnephilid caddisflies in October and November, and ephemerellid mayflies in February and April. Few differences in prey composition between PYOY and YOY salmon were observed. Fish growth was unrelated to prey availability, but gut fullness explained up to 97% of growth variation across seasons. Results suggest that spring and fall are critical periods of feeding for PYOY salmon and that diel feeding intensity shifts seasonally.

  20. STORMVEX: The Storm Peak Lab Cloud Property Validation Experiment Science and Operations Plan

    Energy Technology Data Exchange (ETDEWEB)

    Mace, J; Matrosov, S; Shupe, M; Lawson, P; Hallar, G; McCubbin, I; Marchand, R; Orr, B; Coulter, R; Sedlacek, A; Avallone, L; Long, C

    2010-09-29

    During the Storm Peak Lab Cloud Property Validation Experiment (STORMVEX), a substantial correlative data set of remote sensing observations and direct in situ measurements from fixed and airborne platforms will be created in a winter season, mountainous environment. This will be accomplished by combining mountaintop observations at Storm Peak Laboratory and the airborne National Science Foundation-supported Colorado Airborne Multi-Phase Cloud Study campaign with collocated measurements from the second ARM Mobile Facility (AMF2). We describe in this document the operational plans and motivating science for this experiment, which includes deployment of AMF2 to Steamboat Springs, Colorado. The intensive STORMVEX field phase will begin nominally on 1 November 2010 and extend to approximately early April 2011.

  1. The Effect of Variation of Plyometric Push-Ups on Force-Application Kinetics and Perception of Intensity.

    Science.gov (United States)

    Dhahbi, Wissem; Chaouachi, Anis; Dhahbi, Anis Ben; Cochrane, Jodie; Chèze, Laurence; Burnett, Angus; Chamari, Karim

    2017-02-01

    To examine differences between ground-reaction-force (GRF)-based parameters collected from 5 types of plyometric push-ups. Between-trials reliability and the relationships between parameters were also assessed. Thirty-seven highly active commando soldiers performed 3 trials of 5 variations of the plyometric push-up in a counterbalanced order: standard countermovement push-up (SCPu), standard squat push-up (SSPu), kneeling countermovement push-up (KCPu), kneeling squat push-up (KSPu), and drop-fall push-up (DFPu). Vertical GRF was measured during these exercises using a portable Kistler force plate. The GRF applied by the hands in the starting position (initial force supported), peak GRF and rate of force development during takeoff, flight time, impact force, and rate of force development impact on landing were determined. During standard-position exercises (SCPu and SSPu) the initial force supported and impact force were higher (P push-up exercises ([CMP] SCPu, KCPu, and DFPu) than squat push-up exercises ([SP] SSPu and KSPu). Furthermore, the flight time was greater (P push-up exercises and train athletes' muscle power by correctly interpreting GRF-based parameters. However, caution is required as some parameters had marginal absolute reliability.

  2. Peak Experience Project

    Science.gov (United States)

    Scott, Daniel G.; Evans, Jessica

    2010-01-01

    This paper emerges from the continued analysis of data collected in a series of international studies concerning Childhood Peak Experiences (CPEs) based on developments in understanding peak experiences in Maslow's hierarchy of needs initiated by Dr Edward Hoffman. Bridging from the series of studies, Canadian researchers explore collected…

  3. Effect of variations in rainfall intensity on slope stability in Singapore

    OpenAIRE

    Christofer Kristo; Harianto Rahardjo; Alfrendo Satyanaga

    2017-01-01

    Numerous scientific evidence has given credence to the true existence and deleterious impacts of climate change. One aspect of climate change is the variations in rainfall patterns, which affect the flux boundary condition across ground surface. A possible disastrous consequence of this change is the occurrence of rainfall-induced slope failures. This paper aims to investigate the variations in rainfall patterns in Singapore and its effect on slope stability. Singapore's historical rainfall d...

  4. Sensitivity of peak flow to the change of rainfall temporal pattern due to warmer climate

    Science.gov (United States)

    Fadhel, Sherien; Rico-Ramirez, Miguel Angel; Han, Dawei

    2018-05-01

    The widely used design storms in urban drainage networks has different drawbacks. One of them is that the shape of the rainfall temporal pattern is fixed regardless of climate change. However, previous studies have shown that the temporal pattern may scale with temperature due to climate change, which consequently affects peak flow. Thus, in addition to the scaling of the rainfall volume, the scaling relationship for the rainfall temporal pattern with temperature needs to be investigated by deriving the scaling values for each fraction within storm events, which is lacking in many parts of the world including the UK. Therefore, this study analysed rainfall data from 28 gauges close to the study area with a 15-min resolution as well as the daily temperature data. It was found that, at warmer temperatures, the rainfall temporal pattern becomes less uniform, with more intensive peak rainfall during higher intensive times and weaker rainfall during less intensive times. This is the case for storms with and without seasonal separations. In addition, the scaling values for both the rainfall volume and the rainfall fractions (i.e. each segment of rainfall temporal pattern) for the summer season were found to be higher than the corresponding results for the winter season. Applying the derived scaling values for the temporal pattern of the summer season in a hydrodynamic sewer network model produced high percentage change of peak flow between the current and future climate. This study on the scaling of rainfall fractions is the first in the UK, and its findings are of importance to modellers and designers of sewer systems because it can provide more robust scenarios for flooding mitigation in urban areas.

  5. The slope-background for the near-peak regimen of photoemission spectra

    Energy Technology Data Exchange (ETDEWEB)

    Herrera-Gomez, A., E-mail: aherrera@qro.cinvestav.mx [CINVESTAV-Unidad Queretaro, Queretaro 76230 (Mexico); Bravo-Sanchez, M. [CINVESTAV-Unidad Queretaro, Queretaro 76230 (Mexico); Aguirre-Tostado, F.S. [Centro de Investigación en Materiales Avanzados, Chihuahua, Chihuahua 31109 (Mexico); Vazquez-Lepe, M.O. [Departamento de Ingeniería de Proyectos, Universidad de Guadalajara, Jalisco 44430 (Mexico)

    2013-08-15

    Highlights: •We propose a method that accounts for the change in the background slope of XPS data. •The slope-background can be derived from Tougaard–Sigmund's transport theory. •The total background is composed by Shirley–Sherwood and Tougaard type backgrounds. •The slope-background employs one parameter that can be related to REELS spectra. •The slope, in conjunction with the Shirley–Sherwood background, provides better fits. -- Abstract: Photoemission data typically exhibits a change on the intensity of the background between the two sides of the peaks. This step is usually very well reproduced by the Shirley–Sherwood background. Yet, the change on the slope of the background in the near-peak regime, although usually present, is not always as obvious to the eye. However, the intensity of the background signal associated with the evolution of its slope can be appreciable. The slope-background is designed to empirically reproduce the change on the slope. Resembling the non-iterative Shirley method, the proposed functional form relates the slope of the background to the integrated signal at higher electron kinetic energies. This form can be predicted under Tougaard–Sigmund's electron transport theory in the near-peak regime. To reproduce both the step and slope changes on the background, it is necessary to employ the slope-background in conjunction with the Shirley–Sherwood background under the active-background method. As it is shown for a series of materials, the application of the slope-background provides excellent fits, is transparent to the operator, and is much more independent of the fitting range than other background methods. The total area assessed through the combination of the slope and the Shirley–Sherwood backgrounds is larger than when only the Shirley–Sherwood background is employed, and smaller than when the Tougaard background is employed.

  6. Absolute peak detection efficiencies of a Ge(Li) detector for high gamma-ray energies

    International Nuclear Information System (INIS)

    Katagiri, Masaki

    1985-11-01

    Absolute peak detection efficiencies of a Ge(Li) detector for gamma-rays of 3.5 MeV to 12 MeV were measured using four (p,γ) reactions and a (n,γ) reaction. Two-line-method was used to obtaine peak detection efficiencies. The efficiencies with the both cases are agreed very well. Utilization of (n,γ) reaction is, therefore, effective for measuring these efficiencies, because high energy gamma-rays can be generated easily by using a neutron source. These results were applied to calibration of a gamma-ray standard source, emitting 6.13 MeV gamma-rays, and of intensities of 56 Co standard gamma-ray source. (author)

  7. Global variations in peak bone mass as studied by dual-energy X-ray absorptiometry

    International Nuclear Information System (INIS)

    McCloskey, E.V.; Dey, A.; Bostock, J.; Parr, R.M.; Aras, N.; Balogh, A.; Borelli, A.; Krishnan, S.; Lobo, G.; Qin, L.L.

    2004-01-01

    In 1994, the International Atomic Energy Agency (IAEA) initiated a 5-year Co-ordinated Research Project (CRP) to determine geographical and racial differences in peak bone mineral density (BMD) in men and women aged 15-49 years. Distinct global differences in BMD were demonstrated at the hip and spine in both men and women approximating to one population standard deviation between populations with the highest and lowest BMD. These differences persist following adjustments for age, sex and body size. Such information is valuable in understanding the reasons for global differences in fracture rate and predicting future trends in fracture incidence. (author)

  8. Variational approach for spatial point process intensity estimation

    DEFF Research Database (Denmark)

    Coeurjolly, Jean-Francois; Møller, Jesper

    is assumed to be of log-linear form β+θ⊤z(u) where z is a spatial covariate function and the focus is on estimating θ. The variational estimator is very simple to implement and quicker than alternative estimation procedures. We establish its strong consistency and asymptotic normality. We also discuss its...... finite-sample properties in comparison with the maximum first order composite likelihood estimator when considering various inhomogeneous spatial point process models and dimensions as well as settings were z is completely or only partially known....

  9. Variation of High-Intensity Therapeutic Ultrasound (HITU) Pressure Field Characterization: Effects of Hydrophone Choice, Nonlinearity, Spatial Averaging and Complex Deconvolution.

    Science.gov (United States)

    Liu, Yunbo; Wear, Keith A; Harris, Gerald R

    2017-10-01

    Reliable acoustic characterization is fundamental for patient safety and clinical efficacy during high-intensity therapeutic ultrasound (HITU) treatment. Technical challenges, such as measurement variation and signal analysis, still exist for HITU exposimetry using ultrasound hydrophones. In this work, four hydrophones were compared for pressure measurement: a robust needle hydrophone, a small polyvinylidene fluoride capsule hydrophone and two fiberoptic hydrophones. The focal waveform and beam distribution of a single-element HITU transducer (1.05 MHz and 3.3 MHz) were evaluated. Complex deconvolution between the hydrophone voltage signal and frequency-dependent complex sensitivity was performed to obtain pressure waveforms. Compressional pressure (p + ), rarefactional pressure (p - ) and focal beam distribution were compared up to 10.6/-6.0 MPa (p + /p - ) (1.05 MHz) and 20.65/-7.20 MPa (3.3 MHz). The effects of spatial averaging, local non-linear distortion, complex deconvolution and hydrophone damage thresholds were investigated. This study showed a variation of no better than 10%-15% among hydrophones during HITU pressure characterization. Published by Elsevier Inc.

  10. Environmental Dependence of Artifact CD Peaks of Chiral Schiff Base 3d-4f Complexes in Soft Mater PMMA Matrix

    Directory of Open Access Journals (Sweden)

    Yu Okamoto

    2011-10-01

    Full Text Available Four chiral Schiff base binuclear 3d-4f complexes (NdNi, NdCu, GdNi, and GdCu have been prepared and characterized by means of electronic and CD spectra, IR spectra, magnetic measurements, and X-ray crystallography (NdNi. A so-called artifact peak of solid state CD spectra, which was characteristic of oriented molecules without free molecular rotation, appeared at about 470 nm. Magnetic data of the complexes in the solid state (powder and in PMMA cast films or solutions indicated that only GdCu preserved molecular structures in various matrixes of soft maters. For the first time, we have used the changes of intensity of artifact CD peaks to detect properties of environmental (media solid state (KBr pellets, PMMA cast films, concentration dependence of PMMA in acetone solutions, and pure acetone solution for chiral 3d-4f complexes (GdCu. Rigid matrix keeping anisotropic orientation exhibited a decrease in the intensity of the artifact CD peak toward negative values. The present results suggest that solid state artifact CD peaks can be affected by environmental viscosity of a soft mater matrix.

  11. Peak Oil and other threatening peaks-Chimeras without substance

    International Nuclear Information System (INIS)

    Radetzki, Marian

    2010-01-01

    The Peak Oil movement has widely spread its message about an impending peak in global oil production, caused by an inadequate resource base. On closer scrutiny, the underlying analysis is inconsistent, void of a theoretical foundation and without support in empirical observations. Global oil resources are huge and expanding, and pose no threat to continuing output growth within an extended time horizon. In contrast, temporary or prolonged supply crunches are indeed plausible, even likely, on account of growing resource nationalism denying access to efficient exploitation of the existing resource wealth.

  12. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    OpenAIRE

    Thomas L. Stöggl; Glenn Björklund; Glenn Björklund

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes.Methods: Thirty-six male (n = 33) and female (n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak): 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high ...

  13. Wuchereria bancrofti in Tanzania: microfilarial periodicity and effect of blood sampling time on microfilarial intensities

    DEFF Research Database (Denmark)

    Simonsen, Poul Erik; Niemann, L.; Meyrowitsch, Dan Wolf

    1997-01-01

    The circadian periodicity of Wuchereria bancrofti microfilarial (mf) intensities in peripheral blood was analysed in a group of infected individuals from an endemic community in north-eastern Tanzania. The mf density was quantified at two-hourly intervals for 24 hours. A clear nocturnal periodic...... of blood sampling before peak time is discussed, and the importance of taking sampling time into consideration when analysing data from epidemiological studies is emphasized. A simple method is devised which can be used to adjust for the influence of time on mf intensities, in studies where accurate...... information on mf intensities is necessary, and where it is impossible to obtain all samples at peak time....

  14. Incorporation of electricity GHG emissions intensity variability into building environmental assessment

    International Nuclear Information System (INIS)

    Cubi, Eduard; Doluweera, Ganesh; Bergerson, Joule

    2015-01-01

    Highlights: • Current building assessment does not account for variability in the electric grid. • A new method incorporates hourly grid variability into building assessment. • The method is complementary with peak-shaving policies. • The assessment method can affect building design decisions. - Abstract: Current building energy and GHG emissions assessments do not account for the variable performance of the electric grid. Incorporating hourly grid variability into building assessment methods can help to better prioritize energy efficiency measures that result in the largest environmental benefits. This article proposes a method to incorporate GHG emissions intensity changes due to grid variability into building environmental assessment. The proposed method encourages building systems that reduce electricity use during peak periods while accounting for differences in grid GHG emissions intensity (i.e., peak shaving is more strongly encouraged in grids that have GHG intense peak generation). A set of energy saving building technologies are evaluated in a set of building variants (office, residential) and grid types (hydro/nuclear dominated, coal/gas dominated) to demonstrate the proposed method. Differences between total GHG emissions calculated with the new method compared with the standard (which assumes a constant GHG emissions intensity throughout the year) are in the 5–15% range when the contribution of electricity to total GHG emissions is more significant. The influence of the method on the assessment of the relative performance of some energy efficiency measures is much higher. For example, the estimated GHG emissions savings with heat pumps and photovoltaics can change by −40% and +20%, respectively, using the new assessment method instead of the standard. These differences in GHG emissions estimates can influence building design decisions. The new method could be implemented easily, and would lead to better decision making and more accurate

  15. Implementation of the Peak Scaling Method for Temperature Measurement in the Laser Heated Diamond Anvil Cell at ALS Beamline 12.2.2

    Science.gov (United States)

    Kunz, M.; MacDowell, A. A.; Yan, J.; Beavers, C.; Doran, A.; Williams, Q. C.

    2016-12-01

    The laser-heated diamond anvil cell (LHDAC) is an important tool in the quest to correlate seismologically derived density and velocity profiles of the Earth with mineralogical models. Precise and accurate measurement of pressure and temperature is crucial for the LHDAC to be useful. Measuring accurate temperatures of laser-heated samples is an ongoing problem. One of the more promising approaches is the `peak-scaling method' as proposed by Kavner and Panero [2004]. This method relies on imaging the entire hot spot, rather than only the peak region onto the grating of a spectrometer. The temperature derived from the entire hotspot is an `average' temperature of the full hot spot. Combined with a monochromatic intensity map of the hot spot and a single temperature spot on this map (normally the peak temperature), a complete temperature map of the LHDAC can be derived. The crux of the method is to determine an accurate peak temperature. Using MATLAB, we derived systematic dependences of the relationship between average temperature and peak temperature as a function of peak temperature, deviations from the grey body assumption [ɛ = f(T,λ)], size and shape of hotspot, as well as the size and position of the spectral window used for spectral fitting. We find these average-to-peak deviations to be significant (5 - 25 %) and hard to control. To avoid biases introduced into the temperature map by erroneous assumptions on the peak temperature, we implemented on ALS beamline 12.2.2 an iterative way to fit a correct peak temperature based on the measured average temperature and measured monochromatic (700 nm) intensity map of the hot spot. The method calculates an average temperature by inverting the Planck equation on the intensities extracted from the monochromatic hotspot image and compares this value to the value obtained by fitting the Wien approximation to the averaged spectrum of the entire hotspot. The peak temperature is adjusted until the difference between

  16. Spectral Variation of NLS1 Galaxy PMN J0948+0022

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... Four well-sampled Spectral Energy Distributions (SEDs) of PMN J0948+0022 are fitted with the syn+SSC+EC model to derive the physical parameters of its jets and to investigate the spectral variations of its SEDs. A tentative correlation between the peak luminosity (c) and peak frequency (c) of its ...

  17. How avian nest site selection responds to predation risk: Testing an 'adaptive peak hypothesis'

    Science.gov (United States)

    Quresh S. Latif; Sacha K. Heath; John T. Rotenberry

    2012-01-01

    1. Nest predation limits avian fitness, so birds should favour nest sites that minimize predation risk. Nevertheless, preferred nest microhabitat features are often uncorrelated with apparent variation in predation rates. 2. This lack of congruence between theory-based expectation and empirical data may arise when birds already occupy ‘adaptive peaks’. If birds nest...

  18. Individual Variation in Hunger, Energy Intake, and Ghrelin Responses to Acute Exercise.

    Science.gov (United States)

    King, James A; Deighton, Kevin; Broom, David R; Wasse, Lucy K; Douglas, Jessica A; Burns, Stephen F; Cordery, Philip A; Petherick, Emily S; Batterham, Rachel L; Goltz, Fernanda R; Thackray, Alice E; Yates, Thomas; Stensel, David J

    2017-06-01

    This study aimed to characterize the immediate and extended effect of acute exercise on hunger, energy intake, and circulating acylated ghrelin concentrations using a large data set of homogenous experimental trials and to describe the variation in responses between individuals. Data from 17 of our group's experimental crossover trials were aggregated yielding a total sample of 192 young, healthy males. In these studies, single bouts of moderate to high-intensity aerobic exercise (69% ± 5% V˙O2 peak; mean ± SD) were completed with detailed participant assessments occurring during and for several hours postexercise. Mean hunger ratings were determined during (n = 178) and after (n = 118) exercise from visual analog scales completed at 30-min intervals, whereas ad libitum energy intake was measured within the first hour after exercise (n = 60) and at multiple meals (n = 128) during the remainder of trials. Venous concentrations of acylated ghrelin were determined at strategic time points during (n = 118) and after (n = 89) exercise. At group level, exercise transiently suppressed hunger (P hunger and circulating acylated ghrelin concentrations with notable diversity between individuals. Care must be taken to distinguish true interindividual variation from random differences within normal limits.

  19. Analysis of the Diurnal Variation of the Global Electric Circuit Obtained From Different Numerical Models

    Science.gov (United States)

    Jánský, Jaroslav; Lucas, Greg M.; Kalb, Christina; Bayona, Victor; Peterson, Michael J.; Deierling, Wiebke; Flyer, Natasha; Pasko, Victor P.

    2017-12-01

    This work analyzes different current source and conductivity parameterizations and their influence on the diurnal variation of the global electric circuit (GEC). The diurnal variations of the current source parameterizations obtained using electric field and conductivity measurements from plane overflights combined with global Tropical Rainfall Measuring Mission satellite data give generally good agreement with measured diurnal variation of the electric field at Vostok, Antarctica, where reference experimental measurements are performed. An approach employing 85 GHz passive microwave observations to infer currents within the GEC is compared and shows the best agreement in amplitude and phase with experimental measurements. To study the conductivity influence, GEC models solving the continuity equation in 3-D are used to calculate atmospheric resistance using yearly averaged conductivity obtained from the global circulation model Community Earth System Model (CESM). Then, using current source parameterization combining mean currents and global counts of electrified clouds, if the exponential conductivity is substituted by the conductivity from CESM, the peak to peak diurnal variation of the ionospheric potential of the GEC decreases from 24% to 20%. The main reason for the change is the presence of clouds while effects of 222Rn ionization, aerosols, and topography are less pronounced. The simulated peak to peak diurnal variation of the electric field at Vostok is increased from 15% to 18% from the diurnal variation of the global current in the GEC if conductivity from CESM is used.

  20. Simulation of geomagnetic field variations during an intensive magnetic storm

    International Nuclear Information System (INIS)

    Fel'dshtejn, Ya.I.; Dremukhin, L.A.; Veshcherova, U.B.

    1993-01-01

    The intensity of asymmetric part of magnetic field of ring current is closely linked with energy flow entering the magnetosphere from solar wind. Quantitative description assumes usage of data on parameters of solar wind before few hours

  1. Archeomagnetic Intensity Spikes: Global or Regional Geomagnetic Field Features?

    Directory of Open Access Journals (Sweden)

    Monika Korte

    2018-03-01

    Full Text Available Variations of the geomagnetic field prior to direct observations are inferred from archeo- and paleomagnetic experiments. Seemingly unusual variations not seen in the present-day and historical field are of particular interest to constrain the full range of core dynamics. Recently, archeomagnetic intensity spikes, characterized by very high field values that appear to be associated with rapid secular variation rates, have been reported from several parts of the world. They were first noted in data from the Levant at around 900 BCE. A recent re-assessment of previous and new Levantine data, involving a rigorous quality assessment, interprets the observations as an extreme local geomagnetic high with at least two intensity spikes between the 11th and 8th centuries BCE. Subsequent reports of similar features from Asia, the Canary Islands and Texas raise the question of whether such features might be common occurrences, or whether they might even be part of a global magnetic field feature. Here we use spherical harmonic modeling to test two hypotheses: firstly, whether the Levantine and other potential spikes might be associated with higher dipole field intensity than shown by existing global field models around 1,000 BCE, and secondly, whether the observations from different parts of the world are compatible with a westward drifting intense flux patch. Our results suggest that the spikes originate from intense flux patches growing and decaying mostly in situ, combined with stronger and more variable dipole moment than shown by previous global field models. Axial dipole variations no more than 60% higher than observed in the present field, probably within the range of normal geodynamo behavior, seem sufficient to explain the observations.

  2. Affective Responses to Repeated Sessions of High-Intensity Interval Training.

    Science.gov (United States)

    Saanijoki, Tiina; Nummenmaa, Lauri; Eskelinen, Jari-Joonas; Savolainen, Anna M; Vahlberg, Tero; Kalliokoski, Kari K; Hannukainen, Jarna C

    2015-12-01

    Vigorous exercise feels unpleasant, and negative emotions may discourage adherence to regular exercise. We quantified the subjective affective responses to short-term high-intensity interval training (HIT) in comparison with moderate-intensity continuous training (MIT). Twenty-six healthy middle-age (mean age, 47 ± 5 yr; mean VO2peak, 34.2 ± 4.1 mL·kg⁻¹·min⁻¹) sedentary men were randomized into HIT (n = 13, 4-6 × 30 s of all-out cycling efforts at approximately 180% of peak workload with 4-min recovery) or MIT (n = 13, 40- to 60-min continuous cycling at 60% of peak workload) groups, performing six sessions within two weeks. Perceived exertion, stress, and affective state were recorded before, during, and after each session. Perceived exertion and arousal were higher, and affective state, more negative during the HIT than that during MIT sessions (P training. Peak oxygen consumption increased (P training). Short-term HIT and MIT are equally effective in improving aerobic fitness, but HIT increases experience of negative emotions and exertion in sedentary middle-age men. This may limit the adherence to this time-effective training mode, even though displeasure lessens over time and suggests similar mental adaptations to both MIT and HIT.

  3. Cardiorespiratory Responses and Prediction of Peak Oxygen Uptake during the Shuttle Walking Test in Healthy Sedentary Adult Men

    Science.gov (United States)

    Neves, Camila D. C.; Lacerda, Ana Cristina Rodrigues; Lage, Vanessa K. S.; Lima, Liliana P.; Fonseca, Sueli F.; de Avelar, Núbia C. P.; Teixeira, Mauro M.; Mendonça, Vanessa A.

    2015-01-01

    Background The application of the Shuttle Walking Test (SWT) to assess cardiorespiratory fitness and the intensity of this test in healthy participants has rarely been studied. This study aimed to assess and correlate the cardiorespiratory responses of the SWT with the cardiopulmonary exercise testing (CEPT) and to develop a regression equation for the prediction of peak oxygen uptake (VO2 peak) in healthy sedentary adult men. Methods In the first stage of this study, 12 participants underwent the SWT and the CEPT on a treadmill. In the second stage, 53 participants underwent the SWT twice. In both phases, the VO2 peak, respiratory exchange ratio (R), and heart rate (HR) were evaluated. Results Similar results in VO2 peak (P>0.05), R peak (P>0.05) and predicted maximum HR (P>0.05) were obtained between the SWT and CEPT. Both tests showed strong and significant correlations of VO2 peak (r = 0.704, P = 0.01) and R peak (r = 0.737, P0.05) was found. Conclusions The SWT produced maximal cardiorespiratory responses comparable to the CEPT, and the developed equation showed viability for the prediction of VO2 peak in healthy sedentary men. PMID:25659094

  4. Effect of 1,6-hexamethylene diisocyanate exposure on peak flowmetry in automobile paint shop workers in Iran.

    Science.gov (United States)

    Pourabedian, Siyamak; Barkhordari, Abdullah; Habibi, Ehsanallah; Rismanchiyan, Masoud; Zare, Mohsen

    2010-06-01

    The aim of this study was to investigate the effects of occupational exposure to 1,6-hexamethylene diisocyanate (HDI) on peak flowmetry in automobile body paint shop workers in Iran. We studied a population of 43 car painters exposed to HDI at their workplaces. Peak expiratory flow was tested for one working week, from the start to the end of each shift. Air was sampled and HDI analysed in parallel, according to the OSHA 42 method. Daily and weekly HDI exposure averages were (0.42+/-0.1) mg m(-3) and (0.13+/-0.05) mg m(-3), respectively. On painting days, 72 % of workers showed more than a 10 % variation in peak expiratory flow. Inhalation exposure exceeded the threshold limit value (TLV) ten times over. This strongly suggests that HDI affected the peak flowmetry in the studied workers.

  5. Peak power ratio generator

    Science.gov (United States)

    Moyer, R.D.

    A peak power ratio generator is described for measuring, in combination with a conventional power meter, the peak power level of extremely narrow pulses in the gigahertz radio frequency bands. The present invention in a preferred embodiment utilizes a tunnel diode and a back diode combination in a detector circuit as the only high speed elements. The high speed tunnel diode provides a bistable signal and serves as a memory device of the input pulses for the remaining, slower components. A hybrid digital and analog loop maintains the peak power level of a reference channel at a known amount. Thus, by measuring the average power levels of the reference signal and the source signal, the peak power level of the source signal can be determined.

  6. Modification of medium-range order in silica glass by ball-milling: real- and reciprocal-space structural correlations for the first sharp diffraction peak

    International Nuclear Information System (INIS)

    Mukai, Akira; Kohara, Shinji; Uchino, Takashi

    2007-01-01

    We have carried out high-energy x-ray diffraction measurements on mechanically milled silica glass. It has been found that the first sharp diffraction peak (FSDP) in the structure factor S(Q) of silica glass appreciably decreases in intensity as a result of mechanical milling, whereas the observed features of the other peaks in S(Q) almost remain unchanged. The corresponding real-space correlation function of the milled samples shows a marked decrease in intensity at r∼5 A. This gives an experimental manifestation that the dominant real-space structural correlation pertaining to the FSDP occurs at r∼5 A

  7. Modification of medium-range order in silica glass by ball-milling: real- and reciprocal-space structural correlations for the first sharp diffraction peak

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Akira [Department of Chemistry, Kobe University, Kobe 657-8501 (Japan); Kohara, Shinji [SPring-8, Japan Synchrotron Radiation Research Institute, Sayo, Hyogo 679-5198 (Japan); Uchino, Takashi [Department of Chemistry, Kobe University, Kobe 657-8501 (Japan)

    2007-11-14

    We have carried out high-energy x-ray diffraction measurements on mechanically milled silica glass. It has been found that the first sharp diffraction peak (FSDP) in the structure factor S(Q) of silica glass appreciably decreases in intensity as a result of mechanical milling, whereas the observed features of the other peaks in S(Q) almost remain unchanged. The corresponding real-space correlation function of the milled samples shows a marked decrease in intensity at r{approx}5 A. This gives an experimental manifestation that the dominant real-space structural correlation pertaining to the FSDP occurs at r{approx}5 A.

  8. An analysis of China's CO2 emission peaking target and pathways

    Directory of Open Access Journals (Sweden)

    Jian-Kun He

    2014-12-01

    Full Text Available China has set the goal for its CO2 emissions to peak around 2030, which is not only a strategic decision coordinating domestic sustainable development and global climate change mitigation but also an overarching target and a key point of action for China's resource conservation, environmental protection, shift in economic development patterns, and CO2 emission reduction to avoid climate change. The development stage where China maps out the CO2 emission peak target is earlier than that of the developed countries. It is a necessity that the non-fossil energy supplies be able to meet all the increased energy demand for achieving CO2 emission peaking. Given that China's potential GDP annual increasing rate will be more than 4%, and China's total energy demand will continue to increase by approximately 1.0%–1.5% annually around 2030, new and renewable energies will need to increase by 6%–8% annually to meet the desired CO2 emission peak. The share of new and renewable energies in China's total primary energy supply will be approximately 20% by 2030. At that time, the energy consumption elasticity will decrease to around 0.3, and the annual decrease in the rate of CO2 intensity will also be higher than 4% to ensure the sustained growth of GDP. To achieve the CO2 emission peaking target and substantially promote the low-carbon development transformation, China needs to actively promote an energy production and consumption revolution, the innovation of advanced energy technologies, the reform of the energy regulatory system and pricing mechanism, and especially the construction of a national carbon emission cap and trade system.

  9. Non-invasive treatment efficacy evaluation for high-intensity focused ultrasound therapy using magnetically induced magnetoacoustic measurement

    Science.gov (United States)

    Guo, Gepu; Wang, Jiawei; Ma, Qingyu; Tu, Juan; Zhang, Dong

    2018-04-01

    Although the application of high intensity focused ultrasound (HIFU) has been demonstrated to be a non-invasive treatment technology for tumor therapy, the real-time temperature monitoring is still a key issue in the practical application. Based on the temperature-impedance relation, a fixed-point magnetically induced magnetoacoustic measurement technology of treatment efficacy evaluation for tissue thermocoagulation during HIFU therapy is developed with a sensitive indicator of critical temperature monitoring in this study. With the acoustic excitation of a focused transducer in the magnetoacoustic tomography with the magnetic induction system, the distributions of acoustic pressure, temperature, electrical conductivity, and acoustic source strength in the focal region are simulated, and the treatment time dependences of the peak amplitude and the corresponding amplitude derivative under various acoustic powers are also achieved. It is proved that the strength peak of acoustic sources is generated by tissue thermocoagulation with a sharp conductivity variation. The peak amplitude of the transducer collected magnetoacoustic signal increases accordingly along with the increase in the treatment time under a fixed acoustic power. When the temperature in the range with the radial and axial widths of about ±0.46 mm and ±2.2 mm reaches 69 °C, an obvious peak of the amplitude derivative can be achieved and used as a sensitive indicator of the critical status of treatment efficacy. The favorable results prove the feasibility of real-time non-invasive temperature monitoring and treatment efficacy evaluation for HIFU ablation using the magnetically induced magnetoacoustic measurement, and might provide a new strategy for accurate dose control during HIFU therapy.

  10. Construction, test and operation in a high intensity beam of a small system of microstrip gas chambers

    CERN Document Server

    Barr, A J; Boimska, B; Bouclier, Roger; Braem, André; Camps, C; Capéans-Garrido, M; Commichau, V; Dominik, Wojciech; Flügge, G; Gómez, F; Hammarström, R; Hangarter, K; Hoch, M; Labbé, J C; Macke, D; Manzin, G; Meijers, F; Million, Gilbert; Mühlemann, K; Nagaslaev, V P; Peisert, Anna; Ropelewski, Leszek; Runólfsson, O; Sauli, Fabio; Schulte, R; Schulz, M; Sharma, A; Shekhtman, L I; Wolff, C

    1998-01-01

    We describe the construction, test and installation procedures, and the experience gained with the operation of a small but complete system of high rate Micro-Strip Gas Chambers, made on thin boro-silicate glass with a diamond-like coating with chromium or gold strips. A set of detectors, fully equipped with readout electronics and each with an active area of 100x100 mm2, was exposed during six months to a high intensity muon beam at CERN with a peak intensity of ~104 mm-2s-1. Continuous monitoring of the performance of the chambers during the beam runs allowed the evaluation of detection efficiency and the monitoring of accidental rates, as well as the study of ambient induced variations and aging in realistic beam conditions. No significant difference has been found in the operation of under- and over-coated plates. Efficiencies could reach ~98% in best operating conditions, although local lower values were often observed due to missing channels (open strips, broken bonds and dead electronic channels). The ...

  11. Glacial erosion, rock, and peak uplift within the central Transantarctic Mountains

    International Nuclear Information System (INIS)

    Stern, T.A.; Baxter, A.K.

    2002-01-01

    About 1500 m of peak elevation can be ascribed to the isostatic response of valley incision within the central Transantarctic Mountains. This estimate, based on a 3D analysis of topography, and on rock uplift history, represents c. 33% of the maximum peak elevation within the Transantarctic Mountains. Input to the calculation includes a previoulsy published estimate for the variation of flexural rigidity across the western margin of East Antarctica, and a lithospheric free-edge at the Transantarctic Mountains Front. The rebound response is a complex function of lithospheric rigidity, wavelength or erosion, and lithospheric boundary conditions. We also calculate a maximum 4000 m of total rebound due to both valley incision and erosion of mountain tops. This represents 60% of the maximum rock uplift inferred for the mountain front on the bases of fission track data and flexure analysis. (author). 34 refs., 5 figs., 3 tabs

  12. Longitudinal Variation of the Lunar Tide in the Equatorial Electrojet

    Science.gov (United States)

    Yamazaki, Yosuke; Stolle, Claudia; Matzka, Jürgen; Siddiqui, Tarique A.; Lühr, Hermann; Alken, Patrick

    2017-12-01

    The atmospheric lunar tide is one known source of ionospheric variability. The subject received renewed attention as recent studies found a link between stratospheric sudden warmings and amplified lunar tidal perturbations in the equatorial ionosphere. There is increasing evidence from ground observations that the lunar tidal influence on the ionosphere depends on longitude. We use magnetic field measurements from the CHAMP satellite during July 2000 to September 2010 and from the two Swarm satellites during November 2013 to February 2017 to determine, for the first time, the complete seasonal-longitudinal climatology of the semidiurnal lunar tidal variation in the equatorial electrojet intensity. Significant longitudinal variability is found in the amplitude of the lunar tidal variation, while the longitudinal variability in the phase is small. The amplitude peaks in the Peruvian sector (˜285°E) during the Northern Hemisphere winter and equinoxes, and in the Brazilian sector (˜325°E) during the Northern Hemisphere summer. There are also local amplitude maxima at ˜55°E and ˜120°E. The longitudinal variation is partly due to the modulation of ionospheric conductivities by the inhomogeneous geomagnetic field. Another possible cause of the longitudinal variability is neutral wind forcing by nonmigrating lunar tides. A tidal spectrum analysis of the semidiurnal lunar tidal variation in the equatorial electrojet reveals the dominance of the westward propagating mode with zonal wave number 2 (SW2), with secondary contributions by westward propagating modes with zonal wave numbers 3 (SW3) and 4 (SW4). Eastward propagating waves are largely absent from the tidal spectrum. Further study will be required for the relative importance of ionospheric conductivities and nonmigrating lunar tides.

  13. Temporal variation in United States firearm injuries 1993-2008: results from a national data base

    Directory of Open Access Journals (Sweden)

    Randall T. Loder

    2014-01-01

    Full Text Available Abstract: Background: There are few studies that address temporal variation in firearm associated injuries. It was the purpose of this study to analyze the temporal variation in the types and patterns of injuries associated with firearm use from a national data base. Methods: The database used was the Inter-University Consortium for Political and Social Research Firearm Injury Surveillance Study 1993-2008. Emergency department visits associated with firearm use were analyzed for month and day of the week for various demographic variables. Statistical analyses were performed using SUDAAN 10™ software to give national estimates. Temporal variation by month or day was assessed using histograms, circular distributions, and cosinor analyses. Variation by month and day combined were analyzed using three dimensional contours. Results: There were an estimated 1,841,269 injuries. Circular analyses demonstrated a non-uniform distribution for all parameters for both month and day of injury (p less than 0.001. The overall peak was September 15 with several exceptions. Injuries from BB guns had a peak on May 22, a diagnosis of a foreign body on July 11, and patients aged 10 to 14 years on April 9.The peak day was always Saturday/Sunday when significant variation existed. There were many different patterns for month and day combined. Some were “a rapidly rising high mountain starting at sea level” (hunting, or others a “series of mountain ranges starting from a high plain or steppe” (hospital admissions. Conclusions: This study provides altogether new information regarding temporal variation for injuries associated with firearms in the USA. These results can be used to assist medical resource allocation and prevention campaigns. Education campaigns can be emphasized before the peaks for which prevention is desired (eg. BB gun prevention campaigns should be concentrated in March, prior to the April/May peak.

  14. Estimating nonrigid motion from inconsistent intensity with robust shape features

    International Nuclear Information System (INIS)

    Liu, Wenyang; Ruan, Dan

    2013-01-01

    Purpose: To develop a nonrigid motion estimation method that is robust to heterogeneous intensity inconsistencies amongst the image pairs or image sequence. Methods: Intensity and contrast variations, as in dynamic contrast enhanced magnetic resonance imaging, present a considerable challenge to registration methods based on general discrepancy metrics. In this study, the authors propose and validate a novel method that is robust to such variations by utilizing shape features. The geometry of interest (GOI) is represented with a flexible zero level set, segmented via well-behaved regularized optimization. The optimization energy drives the zero level set to high image gradient regions, and regularizes it with area and curvature priors. The resulting shape exhibits high consistency even in the presence of intensity or contrast variations. Subsequently, a multiscale nonrigid registration is performed to seek a regular deformation field that minimizes shape discrepancy in the vicinity of GOIs. Results: To establish the working principle, realistic 2D and 3D images were subject to simulated nonrigid motion and synthetic intensity variations, so as to enable quantitative evaluation of registration performance. The proposed method was benchmarked against three alternative registration approaches, specifically, optical flow, B-spline based mutual information, and multimodality demons. When intensity consistency was satisfied, all methods had comparable registration accuracy for the GOIs. When intensities among registration pairs were inconsistent, however, the proposed method yielded pronounced improvement in registration accuracy, with an approximate fivefold reduction in mean absolute error (MAE = 2.25 mm, SD = 0.98 mm), compared to optical flow (MAE = 9.23 mm, SD = 5.36 mm), B-spline based mutual information (MAE = 9.57 mm, SD = 8.74 mm) and mutimodality demons (MAE = 10.07 mm, SD = 4.03 mm). Applying the proposed method on a real MR image sequence also provided

  15. Periodic Variations in the Coronal Green Line Intensity and their ...

    Indian Academy of Sciences (India)

    tribpo

    behaviour of data results as discussed by Tsubaki (1988) in the green corona line intensity. ... This work was partly supported by the Grant Agency (5017/98) of the Slovak. Academy of Sciences. One of us (M. M.) thanks IAU for travel support.

  16. Variation in ultrafiltered and LMW organic matter fluorescence properties under simulated estuarine mixing transects: 1. Mixing alone

    Science.gov (United States)

    Boyd, Thomas J.; Barham, Bethany P.; Hall, Gregory J.; Osburn, Christopher L.

    2010-09-01

    Ultrafiltered and low molecular weight dissolved organic matter (UDOM and LMW-DOM, respectively) fluorescence was studied under simulated estuarine mixing using samples collected from Delaware, Chesapeake, and San Francisco Bays (USA) transects. UDOM was concentrated by tangential flow ultrafiltration (TFF) from the marine (>33 PSU), mid-estuarine (˜16 PSU), and freshwater (ocean members. LMW fluorescence components fit a decreasing linear mixing model from mid salinities to the ocean end-member, but were more highly fluorescent than mixing alone would predict in lower salinities (shifts were also seen in UDOM peak emission wavelengths with blue-shifting toward the ocean end-member. Humic-type components in UDOM generally showed lower fluorescent intensities at low salinities, higher at mid-salinities, and lower again toward the ocean end-member. T (believed to be proteinaceous) and N (labile organic matter) peaks behaved similarly to each other, but not to B peak fluorescence, which showed virtually no variation in permeate or UDOM mixes with salinity. PCA and PARAFAC models showed similar results suggesting trends could be modeled for DOM end- and mid-member sources. Changes in fluorescence properties due to estuarine mixing may be important when using CDOM as a proxy for DOM cycling in coastal systems.

  17. Fibromyalgia patients' quality of life and pain intensity variation Variação da intensidade da dor e da qualidade de vida de pacientes com fibromialgia

    Directory of Open Access Journals (Sweden)

    José Eduardo Martinez

    2008-12-01

    Full Text Available INTRODUCTION: One of the most reported issues on the Fibromyalgia syndrome is the pain intensity variation and its impact on patients' life quality. OBJECTIVES: 1 to establish the correlation among pain, anxiety and depression intensity perception; 2 to determine whether there is a correlation between pain intensity variation and the impact of fibromyalgia on patients' quality of life. MATERIAL AND METHODS: A study was carried out with 21 patients, who received a diary to register their perceptions on pain, anxiety and depression intensity. The patients have made this procedure three times a day, for a fifteen-day period. The impact on life quality was measured by the the Fibromyalgia Impact Questionaire (FIQ. RESULTS: It was observed a significant variation on pain intensity during the day periods. There was not a significant variation for anxiety and depression through the day periods. It was not observed any significant correlation between pain and depression or pain and anxiety intensity perception at any time of the day, during the study period. When considering the whole study period, it was observed that there was a correlation between pain and anxiety and pain and depression in the morning. CONCLUSION: It is concluded that there is a significant pain variation through the day periods and there is a correlation between pain and anxiety and pain and depression in the morning. There is a significant correlation of life quality with pain in the morning, anxiety in the afternoon and evening; and depression in all periods of the day.INTRODUÇÃO: Uma das questões mais relatadas é a variação da intensidade da dor no decorrer do dia e seu impacto na qualidade de vida. OBJETIVOS: Estabelecer a correlação entre a percepção da intensidade da dor, da ansiedade e da depressão e determinar a correlação entre a variação da intensidade da dor e o impacto na qualidade de vida. MATERIAL E MÉTODOS: Estudou-se 21 pacientes com fibromialgia. As

  18. Estimating grass-clover ratio variations caused by traffic intensities using image analysis

    DEFF Research Database (Denmark)

    Jørgensen, Rasmus Nyholm; Sørensen, Claus Grøn; Green, Ole

    Grass and especially clover have a negative yield response as a function of  traffic intensity.  Conventional grass-clover production for silage have high traffic intensity due to fertilizing with slurry, cutting the grass, rolling the grass into swaths, and collecting and chopping the grass...... to fulfill the aim [1]http://www.ruralni.gov.uk/index/publications/press_articles/dairy-2/role-of-clover.htm...

  19. Pitch peak alignment in an outside focus realization : Frisian-Dutch bilingual speakers’ declarative and imperative intonation patterns

    NARCIS (Netherlands)

    Nota, Amber; Hilton, Nanna; Coler, Matthew

    2016-01-01

    This paper investigates intonational pitch variations and pitch peak alignment in declarative sentences and is part of a larger study of declarative, interrogative and imperative grammatical constructions in the Frisian-Dutch contact situation. Frisian is a minority language spoken in the province

  20. Preanalytical and analytical variation of surface-enhanced laser desorption-ionization time-of-flight mass spectrometry of human serum

    DEFF Research Database (Denmark)

    Albrethsen, Jakob; Bøgebo, Rikke; Olsen, Jesper

    2006-01-01

    BACKGROUND: Surface-enhanced laser desorption-ionization time-of-flight (SELDI-TOF) mass spectrometry of human serum is a potential diagnostic tool in human diseases. In the present study, the preanalytical and analytical variation of SELDI-TOF mass spectrometry of serum was assessed in healthy...... was 18% (6%-34%, n=4) for 16 peaks, and inter-individual CV was 38% (16%-56%, n=16) for 20 peaks. CONCLUSIONS: The pre-analytical and analytical conditions of SELDI-TOF mass spectrometry of serum have a significant impact on the protein peaks, with the number of peaks low and the assay variation high...

  1. Seasonal variation of seismic ambient noise level at King Sejong Station, Antarctica

    Science.gov (United States)

    Lee, W.; Sheen, D.; Seo, K.; Yun, S.

    2009-12-01

    The generation of the secondary- or double-frequency (DF) microseisms with dominant frequencies between 0.1 and 0.5 Hz has been explained by nonlinear second-order pressure perturbations on the ocean bottom due to the interference of two ocean waves of equal wavelengths traveling in opposite directions. Korea Polar Research Institute (KOPRI) has been operating a broadband seismic station (KSJ1) at King George Island (KGI), Antarctica, since 2001. Examining the ambient seismic noise level for the period from 2006 to 2008 at KSJ1, we found a significant seasonal variation in the frequency range 0.1-0.5 Hz. Correlation of the DF peaks with significant ocean wave height and peak wave period models indicates that the oceanic infragravity waves in the Drake Passage is a possible source to excite the DF microseisms at KGI. Location of King Sejong Station, Antarctica Seasonal variations of DF peak, significant wave height, and peak wave period

  2. IVF: exploiting intensity variation function for high-performance pedestrian tracking in forward-looking infrared imagery

    Science.gov (United States)

    Lamberti, Fabrizio; Sanna, Andrea; Paravati, Gianluca; Belluccini, Luca

    2014-02-01

    Tracking pedestrian targets in forward-looking infrared video sequences is a crucial component of a growing number of applications. At the same time, it is particularly challenging, since image resolution and signal-to-noise ratio are generally very low, while the nonrigidity of the human body produces highly variable target shapes. Moreover, motion can be quite chaotic with frequent target-to-target and target-to-scene occlusions. Hence, the trend is to design ever more sophisticated techniques, able to ensure rather accurate tracking results at the cost of a generally higher complexity. However, many of such techniques might not be suitable for real-time tracking in limited-resource environments. This work presents a technique that extends an extremely computationally efficient tracking method based on target intensity variation and template matching originally designed for targets with a marked and stable hot spot by adapting it to deal with much more complex thermal signatures and by removing the native dependency on configuration choices. Experimental tests demonstrated that, by working on multiple hot spots, the designed technique is able to achieve the robustness of other common approaches by limiting drifts and preserving the low-computational footprint of the reference method.

  3. Intensity of low-frequency radiations and the interplanetary magnetic field

    International Nuclear Information System (INIS)

    Larkina, V.I.; Likhter, Ya.I.

    1983-01-01

    The data of measurements of ELF/VLF radiations at ''Interkosmos-13'' artificial Earth satellite in auroral latitudes and in the polar cap in the vernal equinox of 1975 are compared with characteristics of interplanetary magnetic field (IMF). The absence of north-south asymmetry of variations of ELF/VLF-radiation Intensity in the outer ionosphere versus the IMF characteristics is noted. The intensity of natural ELF- and VLF-radiations depends in a complex way on parameters of the magnetospheric plasma: composition and concentration of ''cold'' particles, geomagnetic field intensity, properties of energetic particle fluxes. The considered variations in the radiation amplitude versus the IMF characteristics show the predominant role of the sector structure polarity and IMF Bsub(y) component sign

  4. Rainfall intensity effects on crusting and mode of seedling ...

    African Journals Online (AJOL)

    Predicted changes in rainfall intensity due to climate change are likely to influence key soil health parameters, especially structural attributes and crop growth. Variations in rainfall intensity will impact crop ... and growth in these soils. Keywords: climate change, crusting, mineralogy, penetration resistance, soil organic matter ...

  5. Fit of second order thermoluminescence glow peaks using the logistic distribution function

    International Nuclear Information System (INIS)

    Pagonis, V.; Kitis, G.

    2001-01-01

    A new thermoluminescence glow curve deconvolution (GCD) function is introduced which accurately describes second order thermoluminescence (TL) curves. The logistic asymmetric (LA) statistical probability function is used with the function variables being the maximum peak intensity (I m ), the temperature of the maximum peak intensity (T m ) and the LA width parameter a 2 . An analytical expression is derived from which the activation energy E can be calculated as a function of T m and the LA width parameter a 2 with an accuracy of 2% or better. The accuracy of the fit was tested for E values ranging from 0.7 to 2.5 eV, for s values between 10 5 and 10 25 s -1 , and for trap occupation number n 0 /N between 1 and 10 -6 . The goodness of fit of the logistic asymmetric function is described by the Figure of Merit (FOM) which is found to be of the order of 10 -2 . Preliminary results show that the GCD described here can easily be extended to the description of general order TL glow curves by varying the asymmetry parameter of the logistic asymmetric function. It is concluded that the TL kinetic analysis of first, second and general order TL glow curves can be performed with high accuracy and speed by using commercially available statistical packages that incorporate the Weibull and logistic asymmetric functions. (author)

  6. Acute blood glucose, cardiovascular and exaggerated responses to HIIT and moderate-intensity continuous training in men with type 2 diabetes mellitus.

    Science.gov (United States)

    Wormgoor, Shohn G; Dalleck, Lance C; Zinn, Caryn; Harris, Nigel K

    2018-01-01

    Optimizing exercise-induced physiological responses without increasing the risk of negative exaggerated responses is an important aspect of exercise prescription for people with type 2 diabetes mellitus (T2DM). However, knowledge of acute responses, including exaggerated responses, of different training modalities is limited. The aim of the study was to compare acute physiological responses of moderate-intensity continuous training (MICT) and high-intensity interval training (HIIT) in T2DM. Baseline data were used to randomly assign male participants into supervised training groups for a 12-week intervention. During week 7, participants trialed either a fully progressed MICT (N.=11) or HIIT (N.=11) (combined with resistance training) session. The MICT included 26 minutes at 55% estimated maximum workload (eWLmax) while the HIIT included twelve 1-minute bouts at 95% eWLmax interspersed with 1-minute bouts at 40% eWLmax. While energy expenditure and peak systolic and diastolic blood pressure responses were similar between groups (P=0.47, P=0.71, P=0.56, respectively), peak heart rate, workload and perceived exertion were higher in the HIIT group (P=0.04, PHIIT (36%) participants. While structured MICT and HIIT sessions resulted in comparable acute physiological responses, the individual variations and exaggerated responses, even after preparatory training, necessitated precautionary respite in T2DM men.

  7. Solid state cathodoluminescence and the properties of its two emission peaks

    International Nuclear Information System (INIS)

    Xu Xurong

    2007-01-01

    We discovered solid state cathodoluminescence (SSCL). For its identification we excluded all artifacts, carried out its cross proof and studied its generality. Its spectrum is characterized by the appearance of short wavelength peak when the applied voltage is increased. Three voltage ranges are distinguished, in the lower voltage range we have the long wavelength emission, in the middle range we have both long and short wavelength emissions, and in the higher voltage range we have only the short wavelength emission. The mechanism of this spectral shift lies in the electrical field ionization of excitons. This effect initiates the applicability of band model besides molecular excitons theory. The temporal behaviors of both peaks in SSCL are studied with a method of estimating lifetime by means of frequency dependence on intensity. The lifetime of short wavelength emission is found to be 5 ms and that of long wavelength emission is less than 0.05 ms

  8. Peaking for optimal performance: Research limitations and future directions.

    Science.gov (United States)

    Pyne, David B; Mujika, Iñigo; Reilly, Thomas

    2009-02-01

    A key element of the physical preparation of athletes is the taper period in the weeks immediately preceding competition. Existing research has defined the taper, identified various forms used in contemporary sport, and examined the prescription of training volume, load, intensity, duration, and type (progressive or step). Current limitations include: the lack of studies on team, combative, racquet, and precision (target) sports; the relatively small number of randomized controlled trials; the narrow focus on a single competition (single peak) compared with multiple peaking for weekly, multi-day or multiple events; and limited understanding of the physiological, neuromuscular, and biomechanical basis of the taper. Future research should address these limitations, together with the influence of prior training on optimal tapering strategies, and the interactions between the taper and long-haul travel, heat, and altitude. Practitioners seek information on how to prescribe tapers from season to season during an athlete's career, or a team's progression through a domestic league season, or multi-year Olympic or World Cup cycle. Practical guidelines for planning effective tapers for the Vancouver 2010 and London 2012 Olympics will evolve from both experimental investigations and modelling of successful tapers currently employed in a wide range of sports.

  9. Acute effect of exercise intensity and duration on acylated ghrelin and hunger in men.

    Science.gov (United States)

    Broom, David R; Miyashita, Masashi; Wasse, Lucy K; Pulsford, Richard; King, James A; Thackray, Alice E; Stensel, David J

    2017-03-01

    Acute exercise transiently suppresses the orexigenic gut hormone acylated ghrelin, but the extent to which exercise intensity and duration determine this response is not fully understood. The effects of manipulating exercise intensity and duration on acylated ghrelin concentrations and hunger were examined in two experiments. In experiment one, nine healthy males completed three, 4-h conditions (control, moderate-intensity running (MOD) and vigorous-intensity running (VIG)), with an energy expenditure of ~2.5 MJ induced in both MOD (55-min running at 52% peak oxygen uptake (V.O 2peak )) and VIG (36-min running at 75% V.O 2peak ). In experiment two, nine healthy males completed three, 9-h conditions (control, 45-min running (EX45) and 90-min running (EX90)). Exercise was performed at 70% V.O 2peak In both experiments, participants consumed standardised meals, and acylated ghrelin concentrations and hunger were quantified at predetermined intervals. In experiment one, delta acylated ghrelin concentrations were lower than control in MOD (ES = 0.44, P = 0.01) and VIG (ES = 0.98, P Hunger ratings were similar across the conditions (P = 0.35). In experiment two, delta acylated ghrelin concentrations were lower than control in EX45 (ES = 0.77, P Hunger ratings were lower than control in EX45 (ES = 0.20, P = 0.01) and EX90 (ES = 0.27, P = 0.001); EX45 and EX90 were similar (ES = 0.07, P = 0.34). Hunger and delta acylated ghrelin concentrations remained suppressed at 1.5 h in EX90 but not EX45. In conclusion, exercise intensity, and to a lesser extent duration, are determinants of the acylated ghrelin response to acute exercise. © 2017 Society for Endocrinology.

  10. Ultra-High Intensity Proton Accelerators and their Applications

    International Nuclear Information System (INIS)

    Weng, W. T.

    1997-01-01

    The science and technology of proton accelerators have progressed considerably in the past three decades. Three to four orders of magnitude increase in both peak intensity and average flux have made it possible to construct high intensity proton accelerators for modern applications, such as: spallation neutron sources, kaon factory, accelerator production of tritium, energy amplifier and muon collider drivers. The accelerator design focus switched over from intensity for synchrotrons, to brightness for colliders to halos for spallation sources. An overview of this tremendous progress in both accelerator science and technology is presented, with special emphasis on the new challenges of accelerator physics issues such as: H(-) injection, halo formation and reduction of losses

  11. Ecloud Build-Up Simulations for the FNAL MI for a Mixed Fill Pattern: Dependence on Peak SEY and Pulse Intensity During the Ramp

    International Nuclear Information System (INIS)

    Furman, M.A.

    2010-01-01

    We present simulation results of the build-up of the electron-cloud density n e in three regions of the FNAL Main Injector (MI) for a beam fill pattern made up of 5 double booster batches followed by a 6th single batch. We vary the pulse intensity in the range N t = (2-5) x 10 13 , and the beam kinetic energy in the range E k = 8-120 GeV. We assume a secondary electron emission model qualitatively corresponding to TiN, except that we let the peak value of the secondary electron yield (SEY) (delta) max vary as a free parameter in a fairly broad range. Our main conclusions are: (1) At fixed N t there is a clear threshold behavior of n e as a function of (delta) max in the range ∼ 1.1-1.3. (2) At fixed (delta) max , there is a threshold behavior of n e as a function of N t provided (delta) max is sufficiently high; the threshold value of N t is a function of the characteristics of the region being simulated. (3) The dependence on E k is weak except possibly at transition energy. Most of these results were informally presented to the relevant MI personnel in April 2010.

  12. Variations of bubble cavitation and temperature elevation during lesion formation by high-intensity focused ultrasound.

    Science.gov (United States)

    Zhou, Yufeng; Gao, Xiaobin Wilson

    2013-08-01

    High-intensity focused ultrasound (HIFU) is emerging as an effective therapeutic modality in both thermal ablations for solid tumor/cancer and soft-tissue fragmentation. Mechanical and thermal effects, which play an important role in the HIFU treatment simultaneously, are dependent on the operating parameters and may vary with the progress of therapy. Mechanical erosion in the shape of a "squid," a "dumbbell" lesion with both mechanical and thermal lesions, or a "tadpole" lesion with mechanical erosion at the center and thermal necrosis on the boundary in the transparent gel phantom could be produced correspondingly with the pulse duration of 5-30 ms, which is much longer than histotripsy burst but shorter than the time for tissue boiling, and pulse repetition frequency (PRF) of 0.2-5 Hz. Meanwhile, variations of bubble cavitation (both inertial and stable cavitation) and temperature elevation in the focal region (i.e., z = -2.5, 0, and 2.5 mm) were measured by passive cavitation detection (PCD) and thermocouples during the therapeutic procedure, respectively. Stable cavitation increased with the pulse duration, PRF, and the number of pulses delivered. However, inertial cavitation was found to increase initially and then decrease with long pulse duration and high PRF. Temperature in the pre-focal region is always higher than those at the focal and post-focal position in all tests. Great variations of PCD signals and temperature elevation are due to the generation and persistence of large bubble, which is resistant to collapse and occurs with the increase of pulse duration and PRF. Similar lesion pattern and variations were also observed in ex vivo porcine kidneys. Hyperechoes in the B-mode ultrasound image were comparable to the shape and size of lesions in the dissected tissue. Thermal lesion volume increased with the increase of pulse duration and PRF, but mechanical erosion reached its maximum volume with the pulse duration of 20 ms and PRF of 1

  13. PolyaPeak: Detecting Transcription Factor Binding Sites from ChIP-seq Using Peak Shape Information

    Science.gov (United States)

    Wu, Hao; Ji, Hongkai

    2014-01-01

    ChIP-seq is a powerful technology for detecting genomic regions where a protein of interest interacts with DNA. ChIP-seq data for mapping transcription factor binding sites (TFBSs) have a characteristic pattern: around each binding site, sequence reads aligned to the forward and reverse strands of the reference genome form two separate peaks shifted away from each other, and the true binding site is located in between these two peaks. While it has been shown previously that the accuracy and resolution of binding site detection can be improved by modeling the pattern, efficient methods are unavailable to fully utilize that information in TFBS detection procedure. We present PolyaPeak, a new method to improve TFBS detection by incorporating the peak shape information. PolyaPeak describes peak shapes using a flexible Pólya model. The shapes are automatically learnt from the data using Minorization-Maximization (MM) algorithm, then integrated with the read count information via a hierarchical model to distinguish true binding sites from background noises. Extensive real data analyses show that PolyaPeak is capable of robustly improving TFBS detection compared with existing methods. An R package is freely available. PMID:24608116

  14. Hurricane Mitch: Peak Discharge for Selected River Reachesin Honduras

    Science.gov (United States)

    Smith, Mark E.; Phillips, Jeffrey V.; Spahr, Norman E.

    2002-01-01

    Hurricane Mitch began as a tropical depression in the Caribbean Sea on 22 October 1998. By 26 October, Mitch had strengthened to a Category 5 storm as defined by the Saffir-Simpson Hurricane Scale (National Climate Data Center, 1999a), and on 27 October was threatening the northern coast of Honduras (fig. 1). After making landfall 2 days later (29 October), the storm drifted south and west across Honduras, wreaking destruction throughout the country before reaching the Guatemalan border on 31 October. According to the National Climate Data Center of the National Oceanic and Atmospheric Administration (National Climate Data Center, 1999b), Hurricane Mitch ranks among the five strongest storms on record in the Atlantic Basin in terms of its sustained winds, barometric pressure, and duration. Hurricane Mitch also was one of the worst Atlantic storms in terms of loss of life and property. The regionwide death toll was estimated to be more than 9,000; thousands of people were reported missing. Economic losses in the region were more than $7.5 billion (U.S. Agency for International Development, 1999). Honduras suffered the most widespread devastation during the storm. More than 5,000 deaths, and economic losses of more than $4 billion, were reported by the Government of Honduras. Honduran officials estimated that Hurricane Mitch destroyed 50 years of economic development. In addition to the human and economic losses, intense flooding and landslides scarred the Honduran landscape - hydrologic and geomorphologic processes throughout the country likely will be affected for many years. As part of the U.S. Government's response to the disaster, the U.S. Geological Survey (USGS) conducted post-flood measurements of peak discharge at 16 river sites throughout Honduras (fig. 2). Such measurements, termed 'indirect' measurements, are used to determine peak flows when direct measurements (using current meters or dye studies, for example) cannot be made. Indirect measurements of

  15. Solar activity effects on cosmic ray intensity and geomagnetic field variation

    International Nuclear Information System (INIS)

    Shukla, A.K.; Shukla, J.P.; Sharma, S.M.; Singh, R.L.; Agrawal, S.P.

    1978-01-01

    An analysis has been performed to statistically correlate the date of solar flare occurrence and its importance with the short term cosmic ray intensity decreases (observed by the high latitude neutron monitors) as well as with the geomagnetic field fluctuation indices (Asub(p) and Dsub(st)), during the period 1973-1976. This period has the particular advantage of being close to a solar minimum to avoid the ambiguity due to closely spaced solar flares. It is found that the intensity decrease starts at least 2-3 days after the date of bright solar flares of Imp 1B, 2B or 3B and the amplitude of the decrease increases with the importance of the solar flare. (author)

  16. Suitability of cerebrospinal fluid as a signal-intensity reference on MRI: evaluation of signal-intensity variations in the lumbosacral dural sac

    International Nuclear Information System (INIS)

    Luoma, E.K.; Luukkonen, R.; Riihimaeki, H.A.; Raininko, R.; Manninen, H.I.; Nummi, P.J.

    1997-01-01

    The suitability of the cerebrospinal fluid (CSF) in the lumbosacral dural sac as an internal signal-intensity reference was studied on magnetic resonance imaging (MRI) of the lumbar spine using a surface coil and motion artefact suppression technique. A signal-intensity reference is needed when signal is compared between images, studies or subjects. Homogeneity of the CSF was estimated visually on T2-weighted images of 60 subjects at 1.5 T and of another 60 subjects at 0.1 T. Spines with a severely narrowed dural sac or marked scoliosis were excluded from the study to avoid partial volume effect. CSF was homogeneous in 82% and 73% of the examinations at 1.5 T and 0.1 T, respectively. The type and location of the local inhomogeneities did not relate to local narrowings of the dural sac. The signal intensity of CSF was measured in 108 examinations at 0.1 T after correcting the spatially-dependent signal-intensity nonuniformities with a phantom-based method. The signal-intensity difference between the CSF in the upper and lower lumbar dural sac was less than 10% in 73% of the examinations. The CSF in the lumbosacral dural sac can be a useful signal-intensity reference for estimation of the signal of the adjacent structures in patients without severe narrowing of the dural sac or marked scoliosis. It may contribute to assessing spinal disease processes. (orig.). With 1 fig., 3 tabs

  17. The high intensity solar cell: Key to low cost photovoltaic power

    Science.gov (United States)

    Sater, B. L.; Goradia, C.

    1975-01-01

    The design considerations and performance characteristics of the 'high intensity' (HI) solar cell are presented. A high intensity solar system was analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency. It is shown that residential sized systems can be produced at less than $1000/kW peak electric power. Due to their superior high intensity performance characteristics compared to the conventional and VMJ cells, HI cells and light concentrators may be the key to low cost photovoltaic power.

  18. Turbulence Hazard Metric Based on Peak Accelerations for Jetliner Passengers

    Science.gov (United States)

    Stewart, Eric C.

    2005-01-01

    Calculations are made of the approximate hazard due to peak normal accelerations of an airplane flying through a simulated vertical wind field associated with a convective frontal system. The calculations are based on a hazard metric developed from a systematic application of a generic math model to 1-cosine discrete gusts of various amplitudes and gust lengths. The math model simulates the three degree-of- freedom longitudinal rigid body motion to vertical gusts and includes (1) fuselage flexibility, (2) the lag in the downwash from the wing to the tail, (3) gradual lift effects, (4) a simplified autopilot, and (5) motion of an unrestrained passenger in the rear cabin. Airplane and passenger response contours are calculated for a matrix of gust amplitudes and gust lengths. The airplane response contours are used to develop an approximate hazard metric of peak normal accelerations as a function of gust amplitude and gust length. The hazard metric is then applied to a two-dimensional simulated vertical wind field of a convective frontal system. The variations of the hazard metric with gust length and airplane heading are demonstrated.

  19. Reduction of intensity variations on a photovoltaic array with compound parabolic concentrators

    Science.gov (United States)

    Greenman, P.; Ogallagher, J.; Winston, R.; Costogue, E.

    1979-01-01

    The reduction of nonuniformities in the intensity distribution of light focused on a photovoltaic array by a compound parabolic concentrator is investigated. The introduction of small distortions into the surfaces of the reflector in order to diffuse the incident collimated light to fill the angular acceptance of the concentrator is calculated by means of ray tracing to decrease the irradiance nonuniformity at the cost of a lowered effective concentration of the concentrator. Measurements of the intensity distribution on a scale test model in terrestrial sunlight with corrugated aluminized mylar reflectors are shown to be in good agreement with the ray tracing results. A two-stage concentrator consisting of a focusing primary and a nonimaging secondary is also shown to result in a fairly uniform intensity distribution except in the case of a 4-deg incidence angle, which may be corrected by the introduction of distortions into one or both concentration stages.

  20. Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Assmann, W., E-mail: walter.assmann@lmu.de; Reinhardt, S.; Lehrack, S.; Edlich, A.; Thirolf, P. G.; Parodi, K. [Department for Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching 85748 (Germany); Kellnberger, S.; Omar, M.; Ntziachristos, V. [Institute for Biological and Medical Imaging, Technische Universität München and Helmholtz Zentrum München, Ingolstädter Landstrasse 1, Neuherberg 85764 (Germany); Moser, M.; Dollinger, G. [Institute for Applied Physics and Measurement Technology, Universität der Bundeswehr, Werner-Heisenberg-Weg 39, Neubiberg 85577 (Germany)

    2015-02-15

    Purpose: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam. Methods: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measured by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE. Results: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10{sup 12} eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 μm and agreed with Geant4 simulations to better than 100 μm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations. Conclusions: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound

  1. High-intensity interval training versus moderate-intensity steady-state training in UK cardiac rehabilitation programmes (HIIT or MISS UK): study protocol for a multicentre randomised controlled trial and economic evaluation.

    Science.gov (United States)

    McGregor, Gordon; Nichols, Simon; Hamborg, Thomas; Bryning, Lucy; Tudor-Edwards, Rhiannon; Markland, David; Mercer, Jenny; Birkett, Stefan; Ennis, Stuart; Powell, Richard; Begg, Brian; Haykowsky, Mark J; Banerjee, Prithwish; Ingle, Lee; Shave, Rob; Backx, Karianne

    2016-11-16

    Current international guidelines for cardiac rehabilitation (CR) advocate moderate-intensity exercise training (MISS, moderate-intensity steady state). This recommendation predates significant advances in medical therapy for coronary heart disease (CHD) and may not be the most appropriate strategy for the 'modern' patient with CHD. High-intensity interval training (HIIT) appears to be a safe and effective alternative, resulting in greater improvements in peak oxygen uptake (VO 2 peak ). To date, HIIT trials have predominantly been proof-of-concept studies in the laboratory setting and conducted outside the UK. The purpose of this multicentre randomised controlled trial is to compare the effects of HIIT and MISS training in patients with CHD attending UK CR programmes. This pragmatic study will randomly allocate 510 patients with CHD to 8 weeks of twice weekly HIIT or MISS training at 3 centres in the UK. HIIT will consist of 10 high-intensity (85-90% peak power output (PPO)) and 10 low-intensity (20-25% PPO) intervals, each lasting 1 min. MISS training will follow usual care recommendations, adhering to currently accepted UK guidelines (ie, >20 min continuous exercise at 40-70% heart rate reserve). Outcome measures will be assessed at baseline, 8 weeks and 12 months. The primary outcome for the trial will be change in VO 2 peak as determined by maximal cardiopulmonary exercise testing. Secondary measures will assess physiological, psychosocial and economic outcomes. The study protocol V.1.0, dated 1 February 2016, was approved by the NHS Health Research Authority, East Midlands-Leicester South Research Ethics Committee (16/EM/0079). Recruitment will start in August 2016 and will be completed in June 2018. Results will be published in peer-reviewed journals, presented at national and international scientific meetings and are expected to inform future national guidelines for exercise training in UK CR. NCT02784873; pre-results. Published by the BMJ

  2. High-intensity interval training: Modulating interval duration in overweight/obese men.

    Science.gov (United States)

    Smith-Ryan, Abbie E; Melvin, Malia N; Wingfield, Hailee L

    2015-05-01

    High-intensity interval training (HIIT) is a time-efficient strategy shown to induce various cardiovascular and metabolic adaptations. Little is known about the optimal tolerable combination of intensity and volume necessary for adaptations, especially in clinical populations. In a randomized controlled pilot design, we evaluated the effects of two types of interval training protocols, varying in intensity and interval duration, on clinical outcomes in overweight/obese men. Twenty-five men [body mass index (BMI) > 25 kg · m(2)] completed baseline body composition measures: fat mass (FM), lean mass (LM) and percent body fat (%BF) and fasting blood glucose, lipids and insulin (IN). A graded exercise cycling test was completed for peak oxygen consumption (VO2peak) and power output (PO). Participants were randomly assigned to high-intensity short interval (1MIN-HIIT), high-intensity interval (2MIN-HIIT) or control groups. 1MIN-HIIT and 2MIN-HIIT completed 3 weeks of cycling interval training, 3 days/week, consisting of either 10 × 1 min bouts at 90% PO with 1 min rests (1MIN-HIIT) or 5 × 2 min bouts with 1 min rests at undulating intensities (80%-100%) (2MIN-HIIT). There were no significant training effects on FM (Δ1.06 ± 1.25 kg) or %BF (Δ1.13% ± 1.88%), compared to CON. Increases in LM were not significant but increased by 1.7 kg and 2.1 kg for 1MIN and 2MIN-HIIT groups, respectively. Increases in VO2peak were also not significant for 1MIN (3.4 ml·kg(-1) · min(-1)) or 2MIN groups (2.7 ml · kg(-1) · min(-1)). IN sensitivity (HOMA-IR) improved for both training groups (Δ-2.78 ± 3.48 units; p < 0.05) compared to CON. HIIT may be an effective short-term strategy to improve cardiorespiratory fitness and IN sensitivity in overweight males.

  3. The end of Peak Oil? Why this topic is still relevant despite recent denials

    International Nuclear Information System (INIS)

    Chapman, Ian

    2014-01-01

    Up until recently Peak Oil was a major discussion point crossing from academic research into mainstream journalism, yet it now attracts far less interest. This paper evaluates the reasons for this and on-going relevance of Peak Oil, considering variations in predictive dates for the phenomenon supported by technological, economic and political issues. Using data from agencies, the validity of each position is assessed looking at reserves, industrial developments and alternative fuels. The complicating issue of demand is also considered. The conclusions are that, supported by commercial interests, an unsubstantiated belief in market and technical solutions, and a narrow paradigmatic focus, critics of Peak Oil theory have used unreliable reserve data, optimistic assumptions about utilisation of unconventional supplies and unrealistic predictions for alternative energy production to discredit the evidence that the resource-limited peak in the world's production of conventional oil has arrived, diverting discussion from what should be a serious topic for energy policy: how we respond to decreasing supplies of one of our most important energy sources. - Highlights: • Key advocates/opponents of Peak Oil reveal their biases. • Reserve calculation methods are considered, showing flaws. • Non-conventional oils’ viability is critiqued and found wanting. • Alternative fuels are found to be unsuitable substitutes for oil. • Demand increases add to the potential for fuel shortages

  4. Sleep and adverse environmental factors in sedated mechanically ventilated pediatric intensive care patients.

    Science.gov (United States)

    Al-Samsam, Rim H; Cullen, Pauline

    2005-09-01

    To document the quantity and architecture of sleep using objective electrophysiologic assessment in sedated mechanically ventilated pediatric intensive care unit patients over a 24-hr period and to investigate the effect of noise and staff interventions on sleep pattern in these subjects. Prospective observational study. Pediatric intensive care unit at a university hospital. A total of 11 patients studied between September 2000 and June 2001, with ages ranging from 3 to 21 months. All patients were intubated, mechanically ventilated, and sedated with morphine and midazolam infusions. Limited sleep polysomnograph, staff interventions, and noise levels were continuously monitored during a 24-hr period. Noise levels were consistently >48 dB(A); the highest night peak reached 103 dB(A). Staff interventions lasted for a mean of 240 (SD 90) mins in a 24-hr period. There was no significant difference in the number of interventions between day and night. Severe alterations to sleep architecture were found throughout the 24 hrs, with no diurnal variations. Active sleep was severely reduced to a mean of 3% (SD 4%; range, 0-11%) of total sleep time. There was severe sleep fragmentation as reflected by the high number (mean, 40 [SD 20]) of wake episodes. The above findings suggest a significant electrophysiologic abnormality of sleep in the pediatric intensive care unit patients. Our pediatric intensive care unit environment is characterized by both, high noise levels and frequent staff interventions. This study has several limitations and future studies are needed, with larger sample size and an attempt to manipulate the environmental factors to minimize their negative effects on sleep.

  5. The correlation of fast OSL component with the TL peak at 3250C in quartz of various origins

    International Nuclear Information System (INIS)

    Kitis, G.; Kiyak, N.; Polymeris, G.S.; Tsirliganis, N.C.

    2010-01-01

    The fast component of the optically stimulated luminescence (OSL) signal in quartz is the basic tool for the optical dating. Its relation with the thermoluminescence (TL) glow-peak at about 325 deg. C is well established for naturally irradiated quartz. This relationship is also an important part of a general model for quartz on which many theoretical simulations of various OSL experimental results have been based. In the present work this relationship is systematically investigated in nine quartz samples of different origin. The linearly modulated OSL (LM-OSL) curves of all quartz samples for stimulation time less than 50 s consists of two components discriminated easily by a computerized curve deconvolution (CCD) analysis. By comparing the un-bleached to the respective bleached TL glow-curve, it is found that the system of these two fast OSL components is directly related with only a small portion of the electron traps responsible for the TL glow-peaks in the temperature region 200-400 0 C. By increasing the stimulation times, besides the two fast components, the medium and the slow components are also obtained. The medium and slow components are clearly related with the main body of the electron traps responsible for TL glow-peaks in the same temperature region 200-400 0 C. Despite their different origin all quartz samples show an appreciable homogeneity concerning the number and time position of the individual components, whereas, the relative TL/OSL intensities vary strongly from sample to sample with the integrated TL intensity being generally much less than the integrated OSL intensity.

  6. Peak capacity and peak capacity per unit time in capillary and microchip zone electrophoresis.

    Science.gov (United States)

    Foley, Joe P; Blackney, Donna M; Ennis, Erin J

    2017-11-10

    The origins of the peak capacity concept are described and the important contributions to the development of that concept in chromatography and electrophoresis are reviewed. Whereas numerous quantitative expressions have been reported for one- and two-dimensional separations, most are focused on chromatographic separations and few, if any, quantitative unbiased expressions have been developed for capillary or microchip zone electrophoresis. Making the common assumption that longitudinal diffusion is the predominant source of zone broadening in capillary electrophoresis, analytical expressions for the peak capacity are derived, first in terms of migration time, diffusion coefficient, migration distance, and desired resolution, and then in terms of the remaining underlying fundamental parameters (electric field, electroosmotic and electrophoretic mobilities) that determine the migration time. The latter expressions clearly illustrate the direct square root dependence of peak capacity on electric field and migration distance and the inverse square root dependence on solute diffusion coefficient. Conditions that result in a high peak capacity will result in a low peak capacity per unit time and vice-versa. For a given symmetrical range of relative electrophoretic mobilities for co- and counter-electroosmotic species (cations and anions), the peak capacity increases with the square root of the electric field even as the temporal window narrows considerably, resulting in a significant reduction in analysis time. Over a broad relative electrophoretic mobility interval [-0.9, 0.9], an approximately two-fold greater amount of peak capacity can be generated for counter-electroosmotic species although it takes about five-fold longer to do so, consistent with the well-known bias in migration time and resolving power for co- and counter-electroosmotic species. The optimum lower bound of the relative electrophoretic mobility interval [μ r,Z , μ r,A ] that provides the maximum

  7. Analysis of low-intensity scintillation spectra

    International Nuclear Information System (INIS)

    Muravsky, V.; Tolstov, S.A.

    2002-01-01

    The maximum likelihood algorithms for nuclides activities estimation from low intensity scintillation γ-ray spectra have been created. The algorithms treat full energy peaks and Compton parts of spectra, and they are more effective than least squares estimators. The factors that could lead to the bias of activity estimates are taken into account. Theoretical analysis of the problem of choosing the optimal set of initial spectra for the spectrum model to minimize errors of the activities estimation has been carried out for the general case of the N-components with Gaussian or Poisson statistics. The obtained criterion allows to exclude superfluous initial spectra of nuclides from the model. A special calibration procedure for scintillation γ-spectrometers has been developed. This procedure is required for application of the maximum likelihood activity estimators processing all the channels of the scintillation γ-spectrum, including the Compton part. It allows one to take into account the influence of the sample mass density variation. The algorithm for testing the spectrum model adequacy to the processed scintillation spectrum has been developed. The algorithms are realized in Borland Pascal 7 as a library of procedures and functions. The developed library is compatible with Delphi 1.0 and higher versions. It can be used as the algorithmic basis for analysis of highly sensitive scintillation γ- and β-spectrometric devices. (author)

  8. Periodic variations of atmospheric electric field on fair weather conditions at YBJ, Tibet

    Science.gov (United States)

    Xu, Bin; Zou, Dan; Chen, Ben Yuan; Zhang, Jin Ye; Xu, Guo Wang

    2013-05-01

    Observations of atmospheric electric field on fair weather conditions from the plateau station, YBJ, Tibet (90°31‧50″ E, 30°06‧38″ N), over the period from 2006 to 2011, are presented in this work. Its periodic modulations are analyzed in frequency-domain by Lomb-Scargle Periodogram method and in time-domain by folding method. The results show that the fair weather atmospheric electric field intensity is modulated weakly by annual cycle, solar diurnal cycle and its several harmonic components. The modulating amplitude of annual cycle is bigger than that of solar diurnal cycle. The annual minimum/maximum nearly coincides with spring/autumn equinox. The detailed spectrum analysis show that the secondary peaks (i.e. sidereal diurnal cycle and semi-sidereal diurnal cycle) nearly disappear along with their primary peaks when the primary signals are subtracted from electric field data sequence. The average daily variation curve exhibits dual-fluctuations, and has obviously seasonal dependence. The mean value is bigger in summer and autumn, but smaller in spring and winter. The daytime fluctuation is affected by the sunrise and sunset effect, the occurring time of which have a little shift with seasons. However, the nightly one has a great dependence on season conditions.

  9. Velocity Spectrum Variation in Central Gulf of Mexico: 9Case Studies for the 2005 Hurricanes

    Science.gov (United States)

    Zhang, F.; Li, C.

    2012-12-01

    Significant near inertial oscillation caused by hurricanes is common in the ocean. The details of the vertical and temporal variations of hurricane induced near inertial oscillation are usually complicated. We have done a case study of such vertical and temporal variations of velocity spectrum focusing around the inertial frequency for the 2005 hurricane season. Data were from a deep water mooring chain containing a series of current meters and 2 ADCPs from June to November 2005. The velocity spectrum is obtained with a 10-day sliding window at different depths for the 40-hour high-passed data to exclude the low frequency Loop Current variations. This gives a temporal variation of the spectrum at different depths. Such variations in velocity spectrum are resulted from the ocean dynamics influenced by the passage of hurricanes. Our preliminary analysis of the results show that (1) right before the center of the hurricane gets closest to the mooring site, there always exists a 2-peak feature of energy at almost all depths; while during the passage of the hurricane these two peaks will merge Into one peak which has a corresponding period of 30.3 to 25.6 hours, encompassing that corresponding to the inertial frequency in this latitude; (2) after the passage of the hurricane, the decay process of energy is also complicated. It is found that the whole profile can be at least divided into 3 layers: surface to 800m, 800m to 1500m, and 1500m to the bottom, which is consistent with the stratification of the water column. It is also found that shift in the peak frequency to either side of the inertial frequency is very common. The main peak of energy can break into several parts during the decay stage, with blue shift and red shift.; ;

  10. Intense upconversion luminescence in ytterbium-sensitized thulium-doped oxychloride germanate glass

    International Nuclear Information System (INIS)

    Sun Hongtao; Zhanga Liyan; Zhang Junjie; Wen Lei; Yu Chunlei; Duan Zhongchao; Dai Shixun; Hu Lili; Jiang Zhonghong

    2005-01-01

    Structural and upconversion fluorescence properties in ytterbium-sensitized thulium-doped oxychloride germanate glass have been studied. The structure of oxychloride germanate glass was investigated by peak-deconvolution of Raman spectrum, and the structural information was obtained from the peak wavenumbers. The Raman spectrum investigation indicates that PbCl 2 plays an important role in the formation of glass network, and has an important influence on the upconversion luminescence. Intense blue and weak red emissions centered at 477 and 650 nm, corresponding to the transitions 1 G 4 → 3 H 6 and 1 G 4 → 3 H 4 , respectively, were observed at room temperature. The possible upconversion mechanisms are discussed and estimated. Intense upconversion luminescence indicates that oxychloride germanate glass can be used as potential host material for upconversion lasers

  11. Time and space variations of trophosherive carbon dioxide over Japan

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, M.; Nakazawa, T.; Aoki, S.

    Aircraft measurements of atmospheric CO/sub 2/ concentration over Japan, initiated in January 1979, have been continued to the present. The average seasonal variation of atmospheric CO/sub 2/ showed maximum concentration early in April and early in May, and minimum concentration in mid-August and mid-September for the lower-most and the upper-most layers of the troposphere, respectively. The peak-to-peak amplitudes of the seasonal variation were 14.5, 9.0 and 7.8 ppmv for the lower, middle and upper tropospheres, respectively. The average rate of annual increase of the CO/sub 2/ concentration over the last 6 years was about 1.3 ppmv yr/sup -1/ with considerable variation with time. The vertical profile of the annual mean value of the CO/sub 2/ concentration was almost the same from year to year; the CO/sub 2/ concentrations decreased gradually with height and the concentration difference between the lowest and highest layers of the troposphere was about 2 ppmv. (authors).

  12. Elevational patterns of genetic variation in the cosmopolitan moss Bryum argenteum (Bryaceae).

    Science.gov (United States)

    Pisa, Sergio; Werner, Olaf; Vanderpoorten, Alain; Magdy, Mahmoud; Ros, Rosa M

    2013-10-01

    The Baas Becking tenet posits that 'everything is everywhere, but the environment selects' to explain cosmopolitan distributions in highly vagile taxa. Bryophyte species show wider distributions than vascular plants and include examples of truly cosmopolitan ranges, which have been interpreted as a result of high dispersal capacities and ecological plasticity. In the current study, we documented patterns of genetic structure and diversity in the cosmopolitan moss Bryum argenteum along an elevational gradient to determine if genetic diversity and structure is homogenized by intense migrations in the lack of ecological differentiation. • 60 specimens were collected in the Sierra Nevada Mountains (Spain) between 100 and 2870 m and sequenced for ITS and rps4. Comparative analyses, genetic diversity estimators, and Mantel's tests were employed to determine the relationship between genetic variation, elevation, and geographic distance and to look for signs of demographic shifts. • Genetic diversity peaked above 1900 m and no signs of demographic shifts were detected at any elevation. There was a strong phylogenetic component in elevational variation. Genetic variation was significantly correlated with elevation, but not with geographic distance. • The results point to the long-term persistence of Bryum argenteum in a range that was glaciated during the Late Pleistocene. Evidence for an environmentally driven pattern of genetic differentiation suggests adaptive divergence. This supports the Baas Becking tenet and indicates that ecological specialization might play a key role in explaining patterns of genetic structure in cosmopolitan mosses.

  13. A study on CT attenuation and MR signal intensity of protein solution

    International Nuclear Information System (INIS)

    Kim, Joung Hae; Choi, Dae Seob; Kim, Soon; Lee, Hyeon Kyeong; Oh, Hyeon Hee; Kim, Seung Hyeon; Lee, Sung Woo; Chang, Kee Hyun; Chung, Jun Ho

    2001-01-01

    To correlate CT attenuation and MR signal intensity with concentration of protein solution. CT and MR examinations of a phantom containing bovine serum albumin solutions of various concentrations ranging from 0 to 55% were performed. CT Hounsfield units(HUs), MR signal intensities, and apparent diffusion coefficients (ADCs) of each albumin solution were measured, and CT HUs and MR signal intensities of the solutions were compared with those of cerebrospinal fluid (CSF), white matter, and cortical gray matter. CT HU increased gradually with increasing albumin concentration. On T1-weighted images(T1WI), signal intensity increased with increasing albumin concentrations of up to 35% but then decreased. On T2-weighted images(T2Wl), gradually decreasing signal intensity and increasing albumin concentration were observed Fluid-attenuated inversion recovery (FLAIR) and diffusion-weighted images (DWls) showed that signal intensity peaked at a concentration of 10% and then gradually decreased. The ADC of the solution gradually decreased as concentration increased. Compared with those of normal brain structures, the CT HUs of solutions at concentrations of over 20% were higher than those of white and gray matter. At T1WI, the signal intensities of 10-45% solutions were similar to or higher than that of the gray matter. At T2Wl, the signal intensities of solutions above 25, 35, and 40% were lower than those of CSF, gray matter, and white matter, respectively. FLAIR images showed that the signal intensities of 5-35% solutions were higher than that of gray matter. The CT attenuation of albumin solution increased gradually with increasing concentration. MR signal intensities peaked at 35% concentration on T1WI and at 10% on FLAIR and DW images, respectively, and then gradually decreased. T2Wl and ADC map images showed gradually decreasing signal intensity and ADC as albumin concentration increased

  14. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    Energy Technology Data Exchange (ETDEWEB)

    Cutshall, N H; Larsen, I L [Oak Ridge National Lab., TN (USA)

    1980-12-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented.

  15. A novel peak detection approach with chemical noise removal using short-time FFT for prOTOF MS data.

    Science.gov (United States)

    Zhang, Shuqin; Wang, Honghui; Zhou, Xiaobo; Hoehn, Gerard T; DeGraba, Thomas J; Gonzales, Denise A; Suffredini, Anthony F; Ching, Wai-Ki; Ng, Michael K; Wong, Stephen T C

    2009-08-01

    Peak detection is a pivotal first step in biomarker discovery from MS data and can significantly influence the results of downstream data analysis steps. We developed a novel automatic peak detection method for prOTOF MS data, which does not require a priori knowledge of protein masses. Random noise is removed by an undecimated wavelet transform and chemical noise is attenuated by an adaptive short-time discrete Fourier transform. Isotopic peaks corresponding to a single protein are combined by extracting an envelope over them. Depending on the S/N, the desired peaks in each individual spectrum are detected and those with the highest intensity among their peak clusters are recorded. The common peaks among all the spectra are identified by choosing an appropriate cut-off threshold in the complete linkage hierarchical clustering. To remove the 1 Da shifting of the peaks, the peak corresponding to the same protein is determined as the detected peak with the largest number among its neighborhood. We validated this method using a data set of serial peptide and protein calibration standards. Compared with MoverZ program, our new method detects more peaks and significantly enhances S/N of the peak after the chemical noise removal. We then successfully applied this method to a data set from prOTOF MS spectra of albumin and albumin-bound proteins from serum samples of 59 patients with carotid artery disease compared to vascular disease-free patients to detect peaks with S/N> or =2. Our method is easily implemented and is highly effective to define peaks that will be used for disease classification or to highlight potential biomarkers.

  16. BLAZAR ANTI-SEQUENCE OF SPECTRAL VARIATION WITHIN INDIVIDUAL BLAZARS: CASES FOR MRK 501 AND 3C 279

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jin; Zhang, Shuang-Nan; Liang, En-Wei, E-mail: zhang.jin@hotmail.com [National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China)

    2013-04-10

    The jet properties of Mrk 501 and 3C 279 are derived by fitting broadband spectral energy distributions (SEDs) with lepton models. The derived {gamma}{sub b} (the break Lorenz factor of the electron distribution) is 10{sup 4}-10{sup 6} for Mrk 501 and 200 {approx} 600 for 3C 279. The magnetic field strength (B) of Mrk 501 is usually one order of magnitude lower than that of 3C 279, but their Doppler factors ({delta}) are comparable. A spectral variation feature where the peak luminosity is correlated with the peak frequency, which is opposite from the blazar sequence, is observed in the two sources. We find that (1) the peak luminosities of the two bumps in the SEDs for Mrk 501 depend on {gamma}{sub b} in both the observer and co-moving frames, but they are not correlated with B and {delta} and (2) the luminosity variation of 3C 279 is dominated by the external Compton (EC) peak and its peak luminosity is correlated with {gamma}{sub b} and {delta}, but anti-correlated with B. These results suggest that {gamma}{sub b} may govern the spectral variation of Mrk 501 and {delta} and B would be responsible for the spectral variation of 3C 279. The narrow distribution of {gamma}{sub b} and the correlation of {gamma}{sub b} and B in 3C 279 would be due to the cooling from the EC process and the strong magnetic field. Based on our brief discussion, we propose that this spectral variation feature may originate from the instability of the corona but not from the variation of the accretion rate as does the blazar sequence.

  17. Peaking-factor of PWR

    International Nuclear Information System (INIS)

    Morioka, Noboru; Kato, Yasuji; Yokoi, M.

    1975-01-01

    Output peaking factor often plays an important role in the safety and operation of nuclear reactors. The meaning of the peaking factor of PWRs is categorized into two features or the peaking factor in core (FQ-core) and the peaking factor on the basis of accident analysis (or FQ-limit). FQ-core is the actual peaking factor realized in nuclear core at the time of normal operation, and FQ-limit should be evaluated from loss of coolant accident and other abnormal conditions. If FQ-core is lower than FQ-limit, the reactor may be operated at full load, but if FQ-core is larger than FQ-limit, reactor output should be controlled lower than FQ-limit. FQ-core has two kinds of values, or the one on the basis of nuclear design, and the other actually measured in reactor operation. The first FQ-core should be named as FQ-core-design and the latter as FQ-core-measured. The numerical evaluation of FQ-core-design is as follows; FQ-core-design of three-dimensions is synthesized with FQ-core horizontal value (X-Y) and FQ-core vertical value, the former one is calculated with ASSY-CORE code, and the latter one with one dimensional diffusion code. For the evaluation of FQ-core-measured, on-site data observation from nuclear reactor instrumentation or off-site data observation is used. (Iwase, T.)

  18. Cardiorespiratory Fitness and Body Composition Responses to Different Intensities and Frequencies of Exercise Training in Colorectal Cancer Survivors.

    Science.gov (United States)

    Devin, James L; Jenkins, David G; Sax, Andrew T; Hughes, Gareth I; Aitken, Joanne F; Chambers, Suzanne K; Dunn, Jeffrey C; Bolam, Kate A; Skinner, Tina L

    2018-06-01

    Deteriorations in cardiorespiratory fitness (V˙o 2peak ) and body composition are associated with poor prognosis after colorectal cancer treatment. However, the optimal intensity and frequency of aerobic exercise training to improve these outcomes in colorectal cancer survivors is unknown. This trial compared 8 weeks of moderate-intensity continuous exercise (MICE; 50 minutes; 70% peak heart rate [HR peak ]; 24 sessions), with high-intensity interval exercise (HIIE; 4 × 4 minutes; 85%-95% HR peak ) at an equivalent (HIIE; 24 sessions) and tapered frequency (HIIE-T; 16 sessions) on V˙o 2peak and on lean and fat mass, measured at baseline, 4, 8, and 12 weeks. Increases in V˙o 2peak were significantly greater after both 4 (+3.0 mL·kg -1 ·min -1 , P = .008) and 8 (+2.3 mL·kg -1 ·min -1 , P = .049) weeks of HIIE compared to MICE. After 8 weeks, there was a significantly greater reduction in fat mass after HIIE compared to MICE (-0.7 kg, P = .038). Four weeks after training, the HIIE group maintained elevated V˙o 2peak (+3.3 mL·kg -1 ·min -1 , P = .006) and reduced fat mass (-0.7 kg, P = .045) compared to the MICE group, with V˙o 2peak in the HIIE-T also being superior to the MICE group (+2.8 mL·kg -1 ·min -1 , P = .013). Compared to MICE, HIIE promotes superior improvements and short-term maintenance of V˙o 2peak and fat mass improvements. HIIE training at a reduced frequency also promotes maintainable cardiorespiratory fitness improvements. In addition to promoting accelerated and superior benefits to the current aerobic exercise guidelines, HIIE promotes clinically relevant improvements even with a substantial reduction in exercise training and for a period after withdrawal. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Experimental Studies of Turbulent Intensity around a Tidal Turbine Support Structure

    Directory of Open Access Journals (Sweden)

    Stuart Walker

    2017-04-01

    Full Text Available Tidal stream energy is a low-carbon energy source. Tidal stream turbines operate in a turbulent environment, and the effect of the structure between the turbine and seabed on this environment is not fully understood. An experimental study using 1:72 scale models based on a commercial turbine design was carried out to study the support structure influence on turbulent intensity around the turbine blades. The study was conducted using the wave-current tank at the Laboratory of Maritime Engineering (LABIMA, University of Florence. A realistic flow environment (ambient turbulent intensity = 11% was established. Turbulent intensity was measured upstream and downstream of a turbine mounted on two different support structures (one resembling a commercial design, the other the same with an additional vertical element, in order to quantify any variation in turbulence and performance between the support structures. Turbine drive power was used to calculate power generation. Acoustic Doppler velocimetry (ADV was used to record and calculate upstream and downstream turbulent intensity. In otherwise identical conditions, performance variation of only 4% was observed between two support structures. Turbulent intensity at 1, 3 and 5 blade diameters, both upstream and downstream, showed variation up to 21% between the two cases. The additional turbulent structures generated by the additional element of the second support structure appears to cause this effect, and the upstream propagation of turbulent intensity is believed to be permitted by surface waves. This result is significant for the prediction of turbine array performance.

  20. Activity measurement by using γ-ray sum peak method considering intake radioactivity and its application

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Narita, Norihiko; Tomita, Kenichi; Katoh, Yoshichika; Mori, Chizuo; Momose, Takumaro; Shinohara, Kunihiko

    2000-01-01

    It is important to measure external and internal exposure dose in the case of accident. The external exposure can be measured by various dosimeters, but the internal exposure is usually calculated from estimated amounts of intake radioactivity because of difficulty of direct measurement. Detection efficiency of human counter used in direct measurement is necessary, but there is no effective method to determine it for non-uniform distribution. The γ-ray sum peak method is tried for the cascade γ-ray emitter under the consideration of small diffusion such as just after intake. After disintegration rates of sources of 46 Sc and 60 Co were determined by 4πβ-γ coincidence method, γ-ray spectra were measured at various positions. Calculated disintegration rates by sum peak method agreed with those by coincidence method within 10%. The similar results were obtained for distributed plural sources in restricted condition. It is also investigated as application for the case that the other nuclide is contained in it. Using peak-to-total ratios measured in advance, the disintegration rates were determined only from the peak intensities. In this case the results had systematic uncertainty of about 20%. (author)

  1. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    International Nuclear Information System (INIS)

    Cutshall, N.H.; Larsen, I.L.

    1980-01-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented. (orig.)

  2. Evaluation of different time domain peak models using extreme learning machine-based peak detection for EEG signal.

    Science.gov (United States)

    Adam, Asrul; Ibrahim, Zuwairie; Mokhtar, Norrima; Shapiai, Mohd Ibrahim; Cumming, Paul; Mubin, Marizan

    2016-01-01

    Various peak models have been introduced to detect and analyze peaks in the time domain analysis of electroencephalogram (EEG) signals. In general, peak model in the time domain analysis consists of a set of signal parameters, such as amplitude, width, and slope. Models including those proposed by Dumpala, Acir, Liu, and Dingle are routinely used to detect peaks in EEG signals acquired in clinical studies of epilepsy or eye blink. The optimal peak model is the most reliable peak detection performance in a particular application. A fair measure of performance of different models requires a common and unbiased platform. In this study, we evaluate the performance of the four different peak models using the extreme learning machine (ELM)-based peak detection algorithm. We found that the Dingle model gave the best performance, with 72 % accuracy in the analysis of real EEG data. Statistical analysis conferred that the Dingle model afforded significantly better mean testing accuracy than did the Acir and Liu models, which were in the range 37-52 %. Meanwhile, the Dingle model has no significant difference compared to Dumpala model.

  3. Physics of high intensity nanosecond electron source

    International Nuclear Information System (INIS)

    Herrera-Gomez, A.; Spicer, W.E.

    1993-08-01

    A new high-intensity, short-time electron source is now being used at the Stanford Linear Accelerator Center (SLAC). Using a GaAs negative affinity semiconductor in the construction of the cathode, it is possible to fulfill operation requirements such as peak currents of tens of amperes, peak widths of the order of nanoseconds, hundreds of hours of operation stability, and electron spin polarization. The cathode is illuminated with high intensity laser pulses, and photoemitted electrons constitute the yield. Because of the high currents, some nonlinear effects are present. Very noticeable is the so-called Charge Limit (CL) effect, which consists of a limit on the total charge in each pulse-that is, the total bunch charge stops increasing as the light pulse total energy increases. In this paper, we explain the mechanism of the CL and how it is caused by the photovoltaic effect. Our treatment is based on the Three-Step model of photoemission. We relate the CL to the characteristics of the surface and bulk of the semiconductor, such as doping, band bending, surface vacuum level, and density of surface states. We also discuss possible ways to prevent the Char's Level effect

  4. Limb Darkening and Planetary Transits: Testing Center-to-limb Intensity Variations and Limb-darkening Directly from Model Stellar Atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Neilson, Hilding R.; Lester, John B. [Department of Astronomy and Astrophysics, University of Toronto, 50 St. George Street, Toronto, ON M5S 3H4 (Canada); McNeil, Joseph T.; Ignace, Richard, E-mail: neilson@astro.utoronto.ca [Department of Physics and Astronomy, East Tennessee State University, Box 70652, Johnson City, TN 37614 (United States)

    2017-08-10

    The transit method, employed by Microvariability and Oscillation of Stars ( MOST ), Kepler , and various ground-based surveys has enabled the characterization of extrasolar planets to unprecedented precision. These results are precise enough to begin to measure planet atmosphere composition, planetary oblateness, starspots, and other phenomena at the level of a few hundred parts per million. However, these results depend on our understanding of stellar limb darkening, that is, the intensity distribution across the stellar disk that is sequentially blocked as the planet transits. Typically, stellar limb darkening is assumed to be a simple parameterization with two coefficients that are derived from stellar atmosphere models or fit directly. In this work, we revisit this assumption and compute synthetic planetary-transit light curves directly from model stellar atmosphere center-to-limb intensity variations (CLIVs) using the plane-parallel Atlas and spherically symmetric SAtlas codes. We compare these light curves to those constructed using best-fit limb-darkening parameterizations. We find that adopting parametric stellar limb-darkening laws leads to systematic differences from the more geometrically realistic model stellar atmosphere CLIV of about 50–100 ppm at the transit center and up to 300 ppm at ingress/egress. While these errors are small, they are systematic, and they appear to limit the precision necessary to measure secondary effects. Our results may also have a significant impact on transit spectra.

  5. THE EFFECTS OF AREA CONTRACTION ON SHOCK WAVE STRENGTH AND PEAK PRESSURE IN SHOCK TUBE

    Directory of Open Access Journals (Sweden)

    A. M. Mohsen

    2012-06-01

    Full Text Available This paper presents an experimental investigation into the effects of area contraction on shock wave strength and peak pressure in a shock tube. The shock tube is an important component of the short duration, high speed fluid flow test facility, available at the Universiti Tenaga Nasional (UNITEN, Malaysia. The area contraction was facilitated by positioning a bush adjacent to the primary diaphragm section, which separates the driver and driven sections. Experimental measurements were performed with and without the presence of the bush, at various diaphragm pressure ratios, which is the ratio of air pressure between the driver (high pressure and driven (low pressure sections. The instantaneous static pressure variations were measured at two locations close to the driven tube end wall, using high sensitivity pressure sensors, which allow the shock wave strength, shock wave speed and peak pressure to be analysed. The results reveal that the area contraction significantly reduces the shock wave strength, shock wave speed and peak pressure. At a diaphragm pressure ratio of 10, the shock wave strength decreases by 18%, the peak pressure decreases by 30% and the shock wave speed decreases by 8%.

  6. Automated asteroseismic peak detections

    DEFF Research Database (Denmark)

    de Montellano, Andres Garcia Saravia Ortiz; Hekker, S.; Themessl, N.

    2018-01-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However......, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible...... of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler....

  7. Environmental impacts of public transport. Why peak-period travellers cause a greater environmental burden than off-peak travellers

    International Nuclear Information System (INIS)

    Rietveld, P.

    2002-01-01

    Given the difference between peak and off-peak occupancy rates in public transport, emissions per traveller kilometre are lower in the peak than in the off-peak period, whereas the opposite pattern is observed for cars. It is argued that it is much more fruitful to analyse environmental effects in marginal terms. This calls for a careful analysis of capacity management policies of public transport suppliers that are facing increased demand during both peak and off-peak periods. A detailed analysis of capacity management by the Netherlands Railways (NS) revealed that off-peak capacity supply is mainly dictated by the demand levels during the peak period. The analysis included the effects of increased frequency and increased vehicle size on environmental impacts, while environmental economies of vehicle size were also taken into account. The main conclusion is that the marginal environmental burden during the peak hours is much higher than is usually thought, whereas it is almost zero during the off-peak period. This implies a pattern that is the precise opposite of the average environmental burden. Thus, an analysis of environmental effects of public transport based on average performance would yield misleading conclusions [nl

  8. Spatial variation and sources of polycyclic aromatic hydrocarbons influenced by intensive land use in an urbanized river network of East China.

    Science.gov (United States)

    Bi, Chunjuan; Wang, Xueping; Jia, Jinpu; Chen, Zhenlou

    2018-06-15

    The concentrations and distribution of polycyclic aromatic hydrocarbons (PAHs) in urbanized river networks are strongly influenced by intensive land use, industrial activities and population density. The spatial variations and their influencing factors of 16 priority PAHs were investigated in surface water, suspended particulate matter (SPM) and sediments among areas under different intensive land uses (industrial areas, agricultural areas, inner city, suburban towns and island areas) in the Shanghai river network, East China. Source apportionment was carried out using isomer ratios of PAHs and Positive Matrix Factorization (PMF). Total concentrations of 16 PAHs ranged from 105.2 to 400.5 ng/L, 108.1 to 1058.8 ng/L and 104.4 to 19,480.0 ng/g in water, SPM and sediments, respectively. The concentrations of PAHs in SPM and sediments varied significantly among areas (p natural gas combustion in water and SPM, and vehicular emissions in sediments. Vehicular emissions were the strongest contributors in SPM and sediments of the inner city, indicating the strong influence of vehicular transportation to PAHs pollution in the urbanized river network. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Ecloud Build-Up Simulations for the FNAL MI for a Mixed Fill Pattern: Dependence on Peak SEY and Pulse Intensity During the Ramp

    Energy Technology Data Exchange (ETDEWEB)

    Furman, M. A.

    2010-12-11

    We present simulation results of the build-up of the electron-cloud density n{sub e} in three regions of the FNAL Main Injector (MI) for a beam fill pattern made up of 5 double booster batches followed by a 6th single batch. We vary the pulse intensity in the range N{sub t} = (2-5) x 10{sup 13}, and the beam kinetic energy in the range E{sub k} = 8-120 GeV. We assume a secondary electron emission model qualitatively corresponding to TiN, except that we let the peak value of the secondary electron yield (SEY) {delta}{sub max} vary as a free parameter in a fairly broad range. Our main conclusions are: (1) At fixed N{sub t} there is a clear threshold behavior of n{sub e} as a function of {delta}{sub max} in the range {approx} 1.1-1.3. (2) At fixed {delta}{sub max}, there is a threshold behavior of n{sub e} as a function of N{sub t} provided {delta}{sub max} is sufficiently high; the threshold value of N{sub t} is a function of the characteristics of the region being simulated. (3) The dependence on E{sub k} is weak except possibly at transition energy. Most of these results were informally presented to the relevant MI personnel in April 2010.

  10. National surveillance of pandemic influenza A(H1N1) infection-related admissions to intensive care units during the 2009-10 winter peak in Denmark: two complementary approaches

    DEFF Research Database (Denmark)

    Gubbels, S; Perner, A; Valentiner-Branth, Palle

    2010-01-01

    close contact with a laboratory-confirmed case. Aggregate numbers of cases were reported weekly: during weeks 48-51 (the peak), reporting was daily. The case-based reports contained demographic and clinical information. The aggregate surveillance registered 93 new cases, the case-based surveillance 61......Surveillance of 2009 pandemic influenza A(H1N1) in Denmark was enhanced during the 2009–10 winter season with a system monitoring the burden of the pandemic on intensive care units (ICUs), in order to inform policymakers and detect shortages in ICUs in a timely manner. Between week 46 of 2009...... and week 11 of 2010, all 36 relevant Danish ICUs reported in two ways: aggregate data were reported online and case-based data on paper. Cases to be reported were defined as patients admitted to an ICU with laboratory-confirmed 2009 pandemic influenza A(H1N1) infection or clinically suspected illness after...

  11. Semi-annual Sq-variation in solar activity cycle

    Science.gov (United States)

    Pogrebnoy, V.; Malosiev, T.

    The peculiarities of semi-annual variation in solar activity cycle have been studied. The data from observatories having long observational series and located in different latitude zones were used. The following observatories were selected: Huancayo (magnetic equator), from 1922 to 1959; Apia (low latitudes), from 1912 to 1961; Moscow (middle latitudes), from 1947 to 1965. Based on the hourly values of H-components, the average monthly diurnal amplitudes (a difference between midday and midnight values), according to five international quiet days, were computed. Obtained results were compared with R (relative sunspot numbers) in the ranges of 0-30R, 40-100R, and 140-190R. It was shown, that the amplitude of semi-annual variation increases with R, from minimum to maximum values, on average by 45%. At equatorial Huancayo observatory, the semi-annual Sq(H)-variation appears especially clearly: its maximums take place at periods of equinoxes (March-April, September-October), and minimums -- at periods of solstices (June-July, December-January). At low (Apia observatory) and middle (Moscow observatory) latitudes, the character of semi-annual variation is somewhat different: it appears during the periods of equinoxes, but considerably less than at equator. Besides, with the growth of R, semi-annual variation appears against a background of annual variation, in the form of second peaks (maximum in June). At observatories located in low and middle latitudes, second peaks become more appreciable with an increase of R (March-April and September-October). During the periods of low solar activity, they are insignificant. This work has been carried out with the support from International Scientific and Technology Center (Project #KR-214).

  12. Population, behavioural and physiological responses of an urban population of black swans to an intense annual noise event.

    Science.gov (United States)

    Payne, Catherine J; Jessop, Tim S; Guay, Patrick-Jean; Johnstone, Michele; Feore, Megan; Mulder, Raoul A

    2012-01-01

    Wild animals in urban environments are exposed to a broad range of human activities that have the potential to disturb their life history and behaviour. Wildlife responses to disturbance can range from emigration to modified behaviour, or elevated stress, but these responses are rarely evaluated in concert. We simultaneously examined population, behavioural and hormonal responses of an urban population of black swans Cygnus atratus before, during and after an annual disturbance event involving large crowds and intense noise, the Australian Formula One Grand Prix. Black swan population numbers were lowest one week before the event and rose gradually over the course of the study, peaking after the event, suggesting that the disturbance does not trigger mass emigration. We also found no difference in the proportion of time spent on key behaviours such as locomotion, foraging, resting or self-maintenance over the course of the study. However, basal and capture stress-induced corticosterone levels showed significant variation, consistent with a modest physiological response. Basal plasma corticosterone levels were highest before the event and decreased over the course of the study. Capture-induced stress levels peaked during the Grand Prix and then also declined over the remainder of the study. Our results suggest that even intensely noisy and apparently disruptive events may have relatively low measurable short-term impact on population numbers, behaviour or physiology in urban populations with apparently high tolerance to anthropogenic disturbance. Nevertheless, the potential long-term impact of such disturbance on reproductive success, individual fitness and population health will need to be carefully evaluated.

  13. Population, behavioural and physiological responses of an urban population of black swans to an intense annual noise event.

    Directory of Open Access Journals (Sweden)

    Catherine J Payne

    Full Text Available Wild animals in urban environments are exposed to a broad range of human activities that have the potential to disturb their life history and behaviour. Wildlife responses to disturbance can range from emigration to modified behaviour, or elevated stress, but these responses are rarely evaluated in concert. We simultaneously examined population, behavioural and hormonal responses of an urban population of black swans Cygnus atratus before, during and after an annual disturbance event involving large crowds and intense noise, the Australian Formula One Grand Prix. Black swan population numbers were lowest one week before the event and rose gradually over the course of the study, peaking after the event, suggesting that the disturbance does not trigger mass emigration. We also found no difference in the proportion of time spent on key behaviours such as locomotion, foraging, resting or self-maintenance over the course of the study. However, basal and capture stress-induced corticosterone levels showed significant variation, consistent with a modest physiological response. Basal plasma corticosterone levels were highest before the event and decreased over the course of the study. Capture-induced stress levels peaked during the Grand Prix and then also declined over the remainder of the study. Our results suggest that even intensely noisy and apparently disruptive events may have relatively low measurable short-term impact on population numbers, behaviour or physiology in urban populations with apparently high tolerance to anthropogenic disturbance. Nevertheless, the potential long-term impact of such disturbance on reproductive success, individual fitness and population health will need to be carefully evaluated.

  14. Drivers of peak sales for pharmaceutical brands

    NARCIS (Netherlands)

    Fischer, Marc; Leeflang, Peter S. H.; Verhoef, Peter C.

    2010-01-01

    Peak sales are an important metric in the pharmaceutical industry. Specifically, managers are focused on the height-of-peak-sales and the time required achieving peak sales. We analyze how order of entry and quality affect the level of peak sales and the time-to-peak-sales of pharmaceutical brands.

  15. Diurnal Variations of Emissions of O2 singlet Delta Near Mars' Northern Summer Solstice

    Science.gov (United States)

    Nosowitz, Jonathon; Ziobron, Elijah; Novak, Robert E.

    2017-10-01

    We are presenting results of O2 singlet Delta emission, a tracer for ozone, in the Martian atmosphere for observations taken before Mars’ Northern summer solstice (Ls = 88o, February 10, 2014 ). The data were taken using CSHELL on the NASA-IRTF telescope located on Mauna Kea in Hawaii. The slit was positioned east-west on Mars and we observed diurnal variations at 20o N and 60o N. Spectral/spatial images were taken with a spectral resolution above 38,000. Mars’ relative velocity of -16 km/s enabled us to separate the Martian emission lines from the telluric absorption lines. Raw images were cleaned by removing dead and hot pixels. The images were then adjusted so that the spatial dimension was perpendicular to the spectral dimension. Extracts at 0.6 arcsec spatial resolution were taken which allowed us to measure Martian emission peaks. The Martian data were calibrated by taking similar observations from a standard star (HR4689) using the temperature, wavelength, and intensity of the star to calibrate the flux density. A Boltzmann analysis was performed on the observed emission peaks to obtain the rotational temperature of the excited O2. From this, the total emission rates were obtained. We found that at both latitudinal locations, the greatest emissions occured between 12:00- 13:00 local time on Mars. The emission intensity increases during the morning hours and then decreases towards sunset. We thank the administration and staff of the NASA-IRTF for observation time and for their assistance during operations of the telescope. We also thank Drs. M. Mumma and G. Villanueva of the NASA Goddard Space Flight Center with whom we collaborate.

  16. Sodium bicarbonate ingestion and individual variability in time-to-peak pH.

    Science.gov (United States)

    Sparks, Andy; Williams, Emily; Robinson, Amy; Miller, Peter; Bentley, David J; Bridge, Craig; Mc Naughton, Lars R

    2017-01-01

    This study determined variability in time-to-peak pH after consumption of 300 mg kg - 1 of sodium bicarbonate. Seventeen participants (mean ± SD: age 21.38 ± 1.5 years; mass 75.8 ± 5.8 kg; height 176.8 ± 7.6 cm) reported to the laboratory where a resting capillary sample was taken. Then, 300 mg kg -1 of NaHCO 3 in 450 ml of flavoured water was ingested. Participants rested for 90 min and repeated blood samples were procured at 10 min intervals for 60 min and then every 5 min until 90 min. Blood pH concentrations were measured. Results suggested that time-to-peak pH (64.41 ± 18.78 min) was variable with a range of 10-85 min and a coefficient of variation of 29.16%. A bimodal distribution occurred, at 65 and 75 min. In conclusion, athletes, when using NaHCO 3 as an ergogenic aid, should determine their time-to-peak pH to best utilize the added buffering capacity this substance allows.

  17. No association of the polymorphisms of the frizzled-related protein gene with peak bone mineral density in Chinese nuclear families

    Directory of Open Access Journals (Sweden)

    Yue Hua

    2010-01-01

    Full Text Available Abstract Background The Wnt/beta-catenin signaling pathway plays an important role in skeletal development. Polymorphisms of frizzled-related protein (FRZB, an antagonist of this pathway, may generate variations in bone mineral density (BMD. In this study, we analyzed the association between FRZB genotypes and peak BMD variation in the spines and hips of two relatively large samples of Chinese female-offspring and male-offspring nuclear families. Methods We recruited 1,260 subjects from 401 female-offspring nuclear families and 1,296 subjects from 427 male-offspring nuclear families and genotyped four tagging single nucleotide polymorphisms (tagSNPs (rs6433993, rs409238, rs288324, and rs4666865 spanning the entire FRZB gene. The SNPs rs288326 and rs7775, which are associated with hip osteoarthritis, were not selected in this study because of their low minor allele frequencies (MAFs in Chinese people. The quantitative transmission disequilibrium test (QTDT was used to analyze the association between each SNP and haplotype with peak BMD in female- and male-offspring nuclear families. Results In the female-offspring nuclear families, we found no evidence of an association between either single SNPs or haplotypes and peak BMD in the spine or hip. In the male-offspring nuclear families, no within-family association was observed for either SNPs or haplotypes, although a significant total association was found between rs4666865 and spine BMD (P = 0.0299. Conclusion Our results suggest that natural variation in FRZB is not a major contributor to the observed variability in peak BMD in either Chinese females or males. Because ethnic differences in the FRZB genotypes may exist, other studies in different population are required to confirm such results.

  18. Interplanetary magnetic field associated changes in cosmic ray intensity and geomagnetic field during 1973-75

    International Nuclear Information System (INIS)

    Singh, R.L.; Shukla, J.P.; Shukla, A.K.; Sharma, S.M.; Agrawal, S.P.

    1979-01-01

    The effects of interplanetary magnetic field (IMF) B and its Bsub(z) component on cosmic ray intensity and geomagnetic field variations have been examined for the period 1973-75. It is observed that: (1) B >= 10γ (magnetic blobs) is pre-requisite in producing cosmic ray intensity and geomagnetic field variations of varying magnitudes, (2) the longer existence of magnetic blobs on successive days produces larger decreases in cosmic ray intensity and geomagnetic field and (3) the southward component (Bsub(z)) of IMF generally gives rise to large Asub(p) changes, though it is not effective in producing cosmic ray intensity decreases. (auth.)

  19. Post-Wildfire Peak Discharge Prediction Methods in Northern New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Ronstadt, Jackie A. [Univ. of New Mexico, Albuquerque, NM (United States)

    2017-12-18

    Recent changes in climate have resulted in a decrease in precipitation and snowpack amounts and increased temperatures in the western United States. As the climate warms, there are also changes to runoff amounts and water availability. Drier and warmer conditions coupled with forest management practices have led to an increase in the frequency and size of forest fires. The 2000 Cerro Grande fire in Los Alamos, New Mexico burned over 43,000 acres and 200 structures. Eleven years later, the Las Conchas fire burned over 156,000 acres and 100 structures, including areas previously burned in 2000, and was considered the largest fire in New Mexico’s history. Both fires burned ponderosa, juniper, piñon and mixed conifer forests, resulting in dramatic decreases in vegetation, changes to surface soils, and alterations to the hydrologic cycle (decreased evapotranspiration, decreased infiltration, increased runoff volume and peak discharge, and decreased time to peak discharge) in surrounding watersheds. The frequency of large, intense “mega-fires” are predicted to increase, thus there is a potential for more post-fire flood damage and more surface water resources to be altered due to water quality issues.

  20. Estimates of peak flood discharge for 21 sites in the Front Range in Colorado in response to extreme rainfall in September 2013

    Science.gov (United States)

    Moody, John A.

    2016-03-21

    Extreme rainfall in September 2013 caused destructive floods in part of the Front Range in Boulder County, Colorado. Erosion from these floods cut roads and isolated mountain communities for several weeks, and large volumes of eroded sediment were deposited downstream, which caused further damage of property and infrastructures. Estimates of peak discharge for these floods and the associated rainfall characteristics will aid land and emergency managers in the future. Several methods (an ensemble) were used to estimate peak discharge at 21 measurement sites, and the ensemble average and standard deviation provided a final estimate of peak discharge and its uncertainty. Because of the substantial erosion and deposition of sediment, an additional estimate of peak discharge was made based on the flow resistance caused by sediment transport effects.Although the synoptic-scale rainfall was extreme (annual exceedance probability greater than 1,000 years, about 450 millimeters in 7 days) for these mountains, the resulting peak discharges were not. Ensemble average peak discharges per unit drainage area (unit peak discharge, [Qu]) for the floods were 1–2 orders of magnitude less than those for the maximum worldwide floods with similar drainage areas and had a wide range of values (0.21–16.2 cubic meters per second per square kilometer [m3 s-1 km-2]). One possible explanation for these differences was that the band of high-accumulation, high-intensity rainfall was narrow (about 50 kilometers wide), oriented nearly perpendicular to the predominant drainage pattern of the mountains, and therefore entire drainage areas were not subjected to the same range of extreme rainfall. A linear relation (coefficient of determination [R2]=0.69) between Qu and the rainfall intensity (ITc, computed for a time interval equal to the time-of-concentration for the drainage area upstream from each site), had the form: Qu=0.26(ITc-8.6), where the coefficient 0.26 can be considered to be an

  1. Signal intensity enhancement of laser ablated volume holograms

    Science.gov (United States)

    Versnel, J. M.; Williams, C.; Davidson, C. A. B.; Wilkinson, T. D.; Lowe, C. R.

    2017-11-01

    Conventional volume holographic gratings (VHGs) fabricated in photosensitive emulsions such as gelatin containing silver salts enable the facile visualization of the holographic image in ambient lighting. However, for the fabrication of holographic sensors, which require more defined and chemically-functionalised polymer matrices, laser ablation has been introduced to create the VHGs and thereby broaden their applications, although the replay signal can be challenging to detect in ambient lighting. When traditional photochemical bleaching solutions used to reduce light scattering and modulate refractive index within the VHG are applied to laser ablated volume holographic gratings, these procedures decrease the holographic peak intensity. This is postulated to occur because both light and dark fringes contain a proportion of metal particles, which upon solubilisation are converted immediately to silver iodide, yielding no net refractive index modulation. This research advances a hypothesis that the reduced intensity of holographic replay signals is linked to a gradient of different sized metal particles within the emulsion, which reduces the holographic signal and may explain why traditional bleaching processes result in a reduction in intensity. In this report, a novel experimental protocol is provided, along with simulations based on an effective medium periodic 1D stack, that offers a solution to increase peak signal intensity of holographic sensors by greater than 200%. Nitric acid is used to etch the silver nanoparticles within the polymer matrix and is thought to remove the smaller particles to generate more defined metal fringes containing a soluble metal salt. Once the grating efficiency has been increased, this salt can be converted to a silver halide, to modulate the refractive index and increase the intensity of the holographic signal. This new protocol has been tested in a range of polymer chemistries; those containing functional groups that help to

  2. Intensive photometry of southern Wolf-Rayet stars

    International Nuclear Information System (INIS)

    Balona, L.A.; Egan, J.; Marang, F.

    1989-01-01

    Results are presented of an intensive photometric campaign on 17 of the brightest southern Wolf-Rayet stars. We report the detection of multi-periodicity in two stars: HD 50896 and HD 96548. It is likely that these periodicities are not coherent but are manifestations of the quasi-periodic variations seen in a few WR stars. A good example of these variations is given by HD 86161. A new eclipsing binary, HD 92740 has been discovered; other stars show periodic variations which can be explained by phase-dependent scattering of the secondary light as it traverses the Wolf-Rayet wind. An important conclusion of this study is that not a single example was found of short-period variations which can be attributed to pulsation. (author)

  3. Analysis of Peak-to-Peak Current Ripple Amplitude in Seven-Phase PWM Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2013-08-01

    Full Text Available Multiphase systems are nowadays considered for various industrial applications. Numerous pulse width modulation (PWM schemes for multiphase voltage source inverters with sinusoidal outputs have been developed, but no detailed analysis of the impact of these modulation schemes on the output peak-to-peak current ripple amplitude has been reported. Determination of current ripple in multiphase PWM voltage source inverters is important for both design and control purposes. This paper gives the complete analysis of the peak-to-peak current ripple distribution over a fundamental period for multiphase inverters, with particular reference to seven-phase VSIs. In particular, peak-to-peak current ripple amplitude is analytically determined as a function of the modulation index, and a simplified expression to get its maximum value is carried out. Although reference is made to the centered symmetrical PWM, being the most simple and effective solution to maximize the DC bus utilization, leading to a nearly-optimal modulation to minimize the RMS of the current ripple, the analysis can be readily extended to either discontinuous or asymmetrical modulations, both carrier-based and space vector PWM. A similar approach can be usefully applied to any phase number. The analytical developments for all different sub-cases are verified by numerical simulations.

  4. Behavioral effects of microwave reinforcement schedules and variations in microwave intensity on albino rats

    Energy Technology Data Exchange (ETDEWEB)

    Vitulli, W.F.; Lambert, J.K.; Brown, S.W.; Quinn, J.M.

    1987-12-01

    The objective of this exploratory investigation was to determine the interactive effects of fixed-ratio scheduling of microwave reinforcement in tandem with changes in microwave intensity. Nine albino rats were conditioned to regulate their thermal environment with microwave radiation while living in a Skinner (operant conditioning) Box in which the ambient temperature was about 27.13 degrees F at the beginning of the session. Each rat obtained a 6-sec. exposure of microwave radiation on a fixed-ratio schedule of MW reinforcement, the values of which varied from FR-1 to FR-30. Intensities of MW radiation were 62.5 W, 125 W, 250 W, and 437.5 W. Sessions lasted for 8 to 9 hr. over an approximate 13-mo. period. The effects of the intensity of microwave reinforcement varied as a function of the ratio value of the schedule used. Continuous reinforcement (FR-1) produced the lowest over-all rates, whereas FR-15, and FR-25 produced the highest over-all rates. Relatively higher thermal-behavior rates occurred under 62.5 W than under any of the other MW intensities for FR-1, FR-15, and FR-25, whereas FR-10 and FR-30 ratios produced intermediate rates of thermal responding which were constant for all values of MW intensity. These data are explained in terms of interactive effects between the local satiation or deprivation properties of the MW intensity and the ratio requirements of the schedule of MW reinforcement.

  5. LRP5 coding polymorphisms influence the variation of peak bone mass in a normal population of French-Canadian women.

    Science.gov (United States)

    Giroux, Sylvie; Elfassihi, Latifa; Cardinal, Guy; Laflamme, Nathalie; Rousseau, François

    2007-05-01

    Bone mineral density has a strong genetic component but it is also influenced by environmental factors making it a complex trait to study. LRP5 gene was previously shown to be involved in rare diseases affecting bone mass. Mutations associated with gain-of-function were described as well as loss-of-function mutations. Following this discovery, many frequent LRP5 polymorphisms were tested against the variation of BMD in the normal population. Heel bone parameters (SOS, BUA) were measured by right calcaneal QUS in 5021 healthy French-Canadian women and for 2104 women, BMD evaluated by DXA at two sites was available (femoral neck (FN) and lumbar spine (LS)). Among women with QUS measures and those with DXA measures, 26.5% and 32.8% respectively were premenopausal, 9.2% and 10.7% were perimenopausal and 64.2% and 56.5% were postmenopausal. About a third of the peri- and postmenopausal women never received hormone therapy. Two single nucleotide coding polymorphisms (Val667Met and Ala1330Val) in LRP5 gene were genotyped by allele-specific PCR. All bone measures were tested individually for associations with each polymorphism by analysis of covariance with adjustment for non genetic risk factors. Furthermore, haplotype analysis was performed to take into account the strong linkage disequilibrium between the two polymorphisms. The two LRP5 polymorphisms were found to be associated with all five bone measures (L2L4 and femoral neck DXA as well as heel SOS, BUA and stiffness index) in the whole sample. Premenopausal women drove the association as expected from the proposed role of LRP5 in peak bone mass. Our results suggest that the Val667Met polymorphism is the causative variant but this remains to be functionally proven.

  6. Spatial variation in water quality within the water bodies of a Peak District catchment and the contribution of moorland condition

    Science.gov (United States)

    Crouch, Tia; Walker, Jonathan

    2013-04-01

    Spatial variation in water quality within the water bodies of a Peak District catchment and the contribution of moorland condition Tia Crouch and Jonathan Walker (Moors for the Future Partnership) Upland locations are significant water supply sources providing over 70% of fresh water in Great Britain. However, the peatlands of the Peak District, Southern Pennines are highly contaminated with anthropogenically derived, atmospherically deposited pollutants, such as heavy metals. This is due to their location between the cities of Manchester and Sheffield, the centre of the 19th century English Industrial Revolution. These peatlands are also severely eroded; therefore erosion could be releasing these pollutants into the fluvial system, representing a threat to both aquatic ecosystems and drinking water supplies. These threats are regulated under the Water Framework Directive (WFD) and the Water Supply Regulations respectively. There are two aims of this project. The first aim is to identify spatial and temporal variability of water quality within the Bamford water treatment works (WTW) catchment. This was achieved by fortnightly spot sampling at eight of the tributaries into the reservoir system. The second aim is to assess the contribution of moorland condition to water quality within the Bamford WTW catchment. Similarly, this was achieved by fortnightly spot sampling at eight moorland streams, draining from a variety of peatland conditions (bare peat, restoration, intact and heather burn). Water samples were analysed for carbon (DOC, POC & TOC), pH, hardness and a suite of heavy metals, including copper, iron and zinc. In addition, stream temperature and stage height was recorded. Preliminary results highlight a number of issues within the Bamford WTW catchment: under the WFD streams are not achieving 'good' status for pH, copper and zinc, and under the Drinking Water Standards (DWS) streams are not achieving targets for aluminium, iron and colour. For example, the

  7. How to use your peak flow meter

    Science.gov (United States)

    ... meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  8. Can We Distinguish Emotions from Faces? Investigation of Implicit and Explicit Processes of Peak Facial Expressions.

    Science.gov (United States)

    Xiao, Ruiqi; Li, Xianchun; Li, Lin; Wang, Yanmei

    2016-01-01

    Most previous studies on facial expression recognition have focused on the moderate emotions; to date, few studies have been conducted to investigate the explicit and implicit processes of peak emotions. In the current study, we used transiently peak intense expression images of athletes at the winning or losing point in competition as materials, and investigated the diagnosability of peak facial expressions at both implicit and explicit levels. In Experiment 1, participants were instructed to evaluate isolated faces, isolated bodies, and the face-body compounds, and eye-tracking movement was recorded. The results revealed that the isolated body and face-body congruent images were better recognized than isolated face and face-body incongruent images, indicating that the emotional information conveyed by facial cues was ambiguous, and the body cues influenced facial emotion recognition. Furthermore, eye movement records showed that the participants displayed distinct gaze patterns for the congruent and incongruent compounds. In Experiment 2A, the subliminal affective priming task was used, with faces as primes and bodies as targets, to investigate the unconscious emotion perception of peak facial expressions. The results showed that winning face prime facilitated reaction to winning body target, whereas losing face prime inhibited reaction to winning body target, suggesting that peak facial expressions could be perceived at the implicit level. In general, the results indicate that peak facial expressions cannot be consciously recognized but can be perceived at the unconscious level. In Experiment 2B, revised subliminal affective priming task and a strict awareness test were used to examine the validity of unconscious perception of peak facial expressions found in Experiment 2A. Results of Experiment 2B showed that reaction time to both winning body targets and losing body targets was influenced by the invisibly peak facial expression primes, which indicated the

  9. Identifying functional reorganization of spelling networks: an individual peak probability comparison approach

    Science.gov (United States)

    Purcell, Jeremy J.; Rapp, Brenda

    2013-01-01

    Previous research has shown that damage to the neural substrates of orthographic processing can lead to functional reorganization during reading (Tsapkini et al., 2011); in this research we ask if the same is true for spelling. To examine the functional reorganization of spelling networks we present a novel three-stage Individual Peak Probability Comparison (IPPC) analysis approach for comparing the activation patterns obtained during fMRI of spelling in a single brain-damaged individual with dysgraphia to those obtained in a set of non-impaired control participants. The first analysis stage characterizes the convergence in activations across non-impaired control participants by applying a technique typically used for characterizing activations across studies: Activation Likelihood Estimate (ALE) (Turkeltaub et al., 2002). This method was used to identify locations that have a high likelihood of yielding activation peaks in the non-impaired participants. The second stage provides a characterization of the degree to which the brain-damaged individual's activations correspond to the group pattern identified in Stage 1. This involves performing a Mahalanobis distance statistics analysis (Tsapkini et al., 2011) that compares each of a control group's peak activation locations to the nearest peak generated by the brain-damaged individual. The third stage evaluates the extent to which the brain-damaged individual's peaks are atypical relative to the range of individual variation among the control participants. This IPPC analysis allows for a quantifiable, statistically sound method for comparing an individual's activation pattern to the patterns observed in a control group and, thus, provides a valuable tool for identifying functional reorganization in a brain-damaged individual with impaired spelling. Furthermore, this approach can be applied more generally to compare any individual's activation pattern with that of a set of other individuals. PMID:24399981

  10. Predicting rheological behavior and baking quality of wheat flour using a GlutoPeak test.

    Science.gov (United States)

    Rakita, Slađana; Dokić, Ljubica; Dapčević Hadnađev, Tamara; Hadnađev, Miroslav; Torbica, Aleksandra

    2018-06-01

    The purpose of this research was to gain an insight into the ability of the GlutoPeak instrument to predict flour functionality for bread making, as well as to determine which of the GlutoPeak parameters show the best potential in predicting dough rheological behavior and baking performance. Obtained results showed that GlutoPeak parameters correlated better with the indices of extensional rheological tests which consider constant dough hydration than with those which were performed at constant dough consistency. The GlutoPeak test showed that it is suitable for discriminating wheat varieties of good quality from those of poor quality, while the most discriminating index was maximum torque (MT). Moreover, MT value of 50 BU and aggregation energy value of 1,300 GPU were set as limits of wheat flour quality. The backward stepwise regression analysis revealed that a high-level prediction of indices which are highly affected by protein content (gluten content, flour water absorption, and dough tenacity) was achieved by using the GlutoPeak indices. Concerning bread quality, a moderate prediction of specific loaf volume and an intense level prediction of breadcrumb textural properties were accomplished by using the GlutoPeak parameters. The presented results indicated that the application of this quick test in wheat transformation chain for the assessment of baking quality would be useful. Baking test is considered as the most reliable method for assessing wheat-baking quality. However, baking test requires trained stuff, time, and large sample amount. These disadvantages have led to a growing demand to develop new rapid tests which would enable prediction of baked product quality with a limited flour size. Therefore, we tested the possibility of using a GlutoPeak tester to predict loaf volume and breadcrumb textural properties. Discrimination of wheat varieties according to quality with a restricted flour amount was also examined. Furthermore, we proposed the limit

  11. Seasonal variation in standardized litter decomposition and effects of elevation and land use at Mount Kilimanjaro

    Science.gov (United States)

    Becker, Joscha; Kuzyakov, Yakov

    2017-04-01

    Decomposition is one of most important ecological steps in organic matter and nutrient cycles, but studies and reliable data from tropical regions in Africa are still scarce. At the global scale, litter decomposition and recycling is controlled by climatic factors and land-use intensity. These factors can be linked to specific ecosystem characteristics along the unique elevation gradient of Mt. Kilimanjaro. Our objectives were to assess the effects of climatic conditions (i.e. elevation) and land-use intensity on C turnover and stabilization and investigated the seasonal variations. Tea-bag Index (see www.teatime4science.org) was used to measure decomposition of a standardized litter substrate by microorganisms and mesofauna coffee plantations or cloud forest (S=0.11) respectively and strongly increased again to a maximum of S=0.41 in the alpine helichrysum ecosystem. During all seasons, we found the highest decomposition rates at mid elevation. However, during both warm seasons the peak is shifted upslope. Savanna experienced the strongest seasonal variation, with 23 times higher S-values in dry- compared to rainy season. Mean annual k-values increased for about 30% with increasing land-use intensity. C stabilization in Mt. Kilimanjaro ecosystems is strongly dependent on seasonal moisture limitation (lower slope) and perennial temperature limitation (alpine zone). Ecosystems at mid elevation (around 1920 & 2120m) represent the interception zone of optimal moisture and temperature conditions. High input and fast turnover drive the C sequestration in these ecosystems, while restrains on decomposition control the C turnover in lower and higher elevation zones. Land-use intensification decreases stabilization from new C inputs in transition zones from savanna to maize monocultures and from traditional homegardens to large-scale coffee plantations.

  12. High-Power, High-Intensity Laser Propagation and Interactions

    Science.gov (United States)

    2014-03-10

    intensity as the weighting function. The full refractive index associated with the laser plasma interaction having a parabolic density variation ...radiation in turn enhances the electron density wave further amplifying the radiation. Considering spatial variations in the z direction only the FEL...effL/ at the entrance to the wiggler where effL is the effective interaction length. This requirement can be expressed by the following inequality

  13. Preparation of highly aligned silicon oxide nanowires with stable intensive photoluminescence

    International Nuclear Information System (INIS)

    Duraia, El-Shazly M.; Mansurov, Z.A.; Tokmolden, S.; Beall, Gary W.

    2010-01-01

    In this work we report the successful formation of highly aligned vertical silicon oxide nanowires. The source of silicon was from the substrate itself without any additional source of silicon. X-ray measurement demonstrated that our nanowires are amorphous. Photoluminescence measurements were conducted through 18 months and indicated that there is a very good intensive emission peaks near the violet regions. The FTIR measurements indicated the existence of peaks at 463, 604, 795 and a wide peak at 1111 cm -1 and this can be attributed to Si-O-Si and Si-O stretching vibrations. We also report the formation of the octopus-like silicon oxide nanowires and the growth mechanism of these structures was discussed.

  14. Preparation of highly aligned silicon oxide nanowires with stable intensive photoluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Duraia, El-Shazly M., E-mail: duraia_physics@yahoo.co [Suez Canal University, Faculty of Science, Physics Department, Ismailia (Egypt); Al-Farabi Kazakh National University, Almaty (Kazakhstan); Institute of Physics and Technology, 11 Ibragimov Street, 050032 Almaty (Kazakhstan); Mansurov, Z.A. [Al-Farabi Kazakh National University, Almaty (Kazakhstan); Tokmolden, S. [Institute of Physics and Technology, 11 Ibragimov Street, 050032 Almaty (Kazakhstan); Beall, Gary W. [Texas State University-San Marcos, Department of Chemistry and Biochemistry, 601 University Dr., San Marcos, TX 78666 (United States)

    2010-02-15

    In this work we report the successful formation of highly aligned vertical silicon oxide nanowires. The source of silicon was from the substrate itself without any additional source of silicon. X-ray measurement demonstrated that our nanowires are amorphous. Photoluminescence measurements were conducted through 18 months and indicated that there is a very good intensive emission peaks near the violet regions. The FTIR measurements indicated the existence of peaks at 463, 604, 795 and a wide peak at 1111 cm{sup -1} and this can be attributed to Si-O-Si and Si-O stretching vibrations. We also report the formation of the octopus-like silicon oxide nanowires and the growth mechanism of these structures was discussed.

  15. Modelling Variable Fire Severity in Boreal Forests: Effects of Fire Intensity and Stand Structure.

    Science.gov (United States)

    Miquelajauregui, Yosune; Cumming, Steven G; Gauthier, Sylvie

    2016-01-01

    It is becoming clear that fires in boreal forests are not uniformly stand-replacing. On the contrary, marked variation in fire severity, measured as tree mortality, has been found both within and among individual fires. It is important to understand the conditions under which this variation can arise. We integrated forest sample plot data, tree allometries and historical forest fire records within a diameter class-structured model of 1.0 ha patches of mono-specific black spruce and jack pine stands in northern Québec, Canada. The model accounts for crown fire initiation and vertical spread into the canopy. It uses empirical relations between fire intensity, scorch height, the percent of crown scorched and tree mortality to simulate fire severity, specifically the percent reduction in patch basal area due to fire-caused mortality. A random forest and a regression tree analysis of a large random sample of simulated fires were used to test for an effect of fireline intensity, stand structure, species composition and pyrogeographic regions on resultant severity. Severity increased with intensity and was lower for jack pine stands. The proportion of simulated fires that burned at high severity (e.g. >75% reduction in patch basal area) was 0.80 for black spruce and 0.11 for jack pine. We identified thresholds in intensity below which there was a marked sensitivity of simulated fire severity to stand structure, and to interactions between intensity and structure. We found no evidence for a residual effect of pyrogeographic region on simulated severity, after the effects of stand structure and species composition were accounted for. The model presented here was able to produce variation in fire severity under a range of fire intensity conditions. This suggests that variation in stand structure is one of the factors causing the observed variation in boreal fire severity.

  16. Peak and end effects in patients' daily recall of pain and fatigue: a within-subjects analysis.

    Science.gov (United States)

    Schneider, Stefan; Stone, Arthur A; Schwartz, Joseph E; Broderick, Joan E

    2011-02-01

    Clinical research often relies on retrospective recall of symptom levels, but the information contained in these ratings is not well understood. The "peak-and-end rule" suggests that the most intense (peak) and final (end) moments of an experience disproportionately influence retrospective judgments, which may bias self-reports of somatic symptoms. This study examined the extent to which peak and end symptom levels systematically affect patients' day-to-day recall of pain and fatigue. Rheumatology patients (N = 97) completed 5 to 6 momentary ratings of pain and fatigue per day as well as a daily recall rating of these symptoms for 28 consecutive days. For pain, peak and end momentary ratings predicted daily recall of average pain beyond the actual average of momentary ratings. This effect was small, yet was confirmed in both between-person and within-person (repeated measures) analyses. For fatigue, neither peak nor end momentary symptoms significantly contributed to daily recall. Of note, the evidence for peak- and end-effects in recall of pain and fatigue varied significantly between individual patients. These findings suggest that peak- and end-effects create a small bias in recall reports of pain, but not fatigue. However, there are considerable individual differences in susceptibility to peak and end heuristics. The peak-end cognitive heuristic could bias end-of-day recall of pain and fatigue. An effect was shown for pain, but not for fatigue. The effects were small and were unlikely to substantially bias end-of-day assessments. Individuals were shown to differ in the degree that the heuristic was associated with recall. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.

  17. Variability of peak shoulder force during wheelchair propulsion in manual wheelchair users with and without shoulder pain.

    Science.gov (United States)

    Moon, Y; Jayaraman, C; Hsu, I M K; Rice, I M; Hsiao-Wecksler, E T; Sosnoff, J J

    2013-01-01

    Manual wheelchair users report a high prevalence of shoulder pain. Growing evidence shows that variability in forces applied to biological tissue is related to musculoskeletal pain. The purpose of this study was to examine the variability of forces acting on the shoulder during wheelchair propulsion as a function of shoulder pain. Twenty-four manual wheelchair users (13 with pain, 11 without pain) participated in the investigation. Kinetic and kinematic data of wheelchair propulsion were recorded for 3 min maintaining a constant speed at three distinct propulsion speeds (fast speed of 1.1 m/s, a self-selected speed, and a slow speed of 0.7 m/s). Peak resultant shoulder forces in the push phase were calculated using inverse dynamics. Within individual variability was quantified as the coefficient of variation of cycle to cycle peak resultant forces. There was no difference in mean peak shoulder resultant force between groups. The pain group had significantly smaller variability of peak resultant force than the no pain group (Ppropulsion variability could be a novel marker of upper limb pain in manual wheelchair users. © 2013.

  18. Calculating computer-generated optical elements to produce arbitrary intensity distributions

    International Nuclear Information System (INIS)

    Findlay, S.; Nugent, K.A.; Scholten, R.E.

    2000-01-01

    Full text: We describe preliminary investigation into using a computer to generate optical elements (CGOEs) with phase-only variation, that will produce an arbitrary intensity distribution in a given image plane. An iterative calculation cycles between the CGOE and the image plane and modifies each according to the appropriate constraints. We extend this to the calculation of defined intensity distributions in two separated planes by modifying both phase and intensity at the CGOE

  19. Observations of Fe XIV Line Intensity Variations in the Solar Corona During the 21 August 2017 Solar Eclipse

    Science.gov (United States)

    Johnson, Payton; Ladd, Edwin

    2018-01-01

    We present time- and spatially-resolved observations of the inner solar corona in the 5303 Å line of Fe XIV, taken during the 21 August 2017 solar eclipse from a field observing site in Crossville, TN. These observations are used to characterize the intensity variations in this coronal emission line, and to compare with oscillation predictions from models for heating the corona by magnetic wave dissipation.The observations were taken with two Explore Scientific ED 102CF 102 mm aperture triplet apochromatic refractors. One system used a DayStar custom-built 5 Å FWHM filter centered on the Fe XIV coronal spectral line and an Atik Titan camera for image collection. The setup produced images with a pixel size of 2.15 arcseconds (~1.5 Mm at the distance to the Sun), and a field of view of 1420 x 1060 arcseconds, covering approximately 20% of the entire solar limb centered near the emerging sunspot complex AR 2672. We obtained images with an exposure time of 0.22 seconds and a frame rate of 2.36 Hz, for a total of 361 images during totality.An identical, co-aligned telescope/camera system observed the same portion of the solar corona, but with a 100 Å FWHM Baader Planetarium solar continuum filter centered on a wavelength of 5400 Å. Images with an exposure time of 0.01 seconds were obtained with a frame rate of 4.05 Hz. These simultaneous observations are used as a control to monitor brightness variations not related to coronal line oscillations.

  20. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis.

    Science.gov (United States)

    Kshirsagar, Parthraj R; Hegde, Harsha; Pai, Sandeep R

    2016-05-01

    This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at -4°C. Contaminant peak was detected in methanol stored in polypropylene microcentrifuge tubes using UFLC analysis. The contaminant peak detected was prominent, sharp detectable at 9.176 ± 0.138 min on a Waters 250-4.6 mm, 4 μ, Nova-Pak C18 column with mobile phase consisting of methanol:water (70:30). It was evident from the study that long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peak. Further, this may mislead in future reporting an unnatural compound by researchers. Long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peakContamination peak with higher area under the curve (609993) was obtained in ultra-flow liquid chromatographic run for methanol stored in PP microcentrifuge tubesContamination peak was detected at retention time 9.113 min with a lambda max of 220.38 nm and 300 mAU intensity on the given chromatographic conditionsGlass vials serve better option over PP microcentrifuge tubes for storing biological samples. Abbreviations used: UFLC: Ultra Flow Liquid Chromatography; LC: Liquid Chromatography; MS: Mass spectrometry; AUC: Area Under Curve.

  1. Postexercise cold-water immersion improves intermittent high-intensity exercise performance in normothermia.

    Science.gov (United States)

    McCarthy, Avina; Mulligan, James; Egaña, Mikel

    2016-11-01

    A brief cold water immersion between 2 continuous high-intensity exercise bouts improves the performance of the latter compared with passive recovery in the heat. We investigated if this effect is apparent in normothermic conditions (∼19 °C), employing an intermittent high-intensity exercise designed to reflect the work performed at the high-intensity domain in team sports. Fifteen young active men completed 2 exhaustive cycling protocols (Ex1 and Ex2: 12 min at 85% ventilatory threshold (VT) and then an intermittent exercise alternating 30-s at 40% peak power (P peak ) and 30 s at 90% P peak to exhaustion) separated by 15 min of (i) passive rest, (ii) 5-min cold-water immersion at 8 °C, and (iii) 10-min cold-water immersion at 8 °C. Core temperature, heart rate, rates of perceived exertion, and oxygen uptake kinetics were not different during Ex1 among conditions. Time to failure during the intermittent exercise was significantly (P immersions (7.2 ± 3.5 min and 7.3 ± 3.3 min, respectively) compared with passive rest (5.8 ± 3.1 min). Core temperature, heart rate, and rates of perceived exertion were significantly (P immersions compared with passive rest. The time constant of phase II oxygen uptake response during the 85% VT bout of Ex2 was not different among the 3 conditions. A postexercise, 5- to 10-min cold-water immersion increases subsequent intermittent high-intensity exercise compared with passive rest in normothermia due, at least in part, to reductions in core temperature, circulatory strain, and effort perception.

  2. Quantitative estimation of infarct size by simultaneous dual radionuclide single photon emission computed tomography: comparison with peak serum creatine kinase activity

    International Nuclear Information System (INIS)

    Kawaguchi, K.; Sone, T.; Tsuboi, H.; Sassa, H.; Okumura, K.; Hashimoto, H.; Ito, T.; Satake, T.

    1991-01-01

    To test the hypothesis that simultaneous dual energy single photon emission computed tomography (SPECT) with technetium-99m (99mTc) pyrophosphate and thallium-201 (201TI) can provide an accurate estimate of the size of myocardial infarction and to assess the correlation between infarct size and peak serum creatine kinase activity, 165 patients with acute myocardial infarction underwent SPECT 3.2 +/- 1.3 (SD) days after the onset of acute myocardial infarction. In the present study, the difference in the intensity of 99mTc-pyrophosphate accumulation was assumed to be attributable to difference in the volume of infarcted myocardium, and the infarct volume was corrected by the ratio of the myocardial activity to the osseous activity to quantify the intensity of 99mTc-pyrophosphate accumulation. The correlation of measured infarct volume with peak serum creatine kinase activity was significant (r = 0.60, p less than 0.01). There was also a significant linear correlation between the corrected infarct volume and peak serum creatine kinase activity (r = 0.71, p less than 0.01). Subgroup analysis showed a high correlation between corrected volume and peak creatine kinase activity in patients with anterior infarctions (r = 0.75, p less than 0.01) but a poor correlation in patients with inferior or posterior infarctions (r = 0.50, p less than 0.01). In both the early reperfusion and the no reperfusion groups, a good correlation was found between corrected infarct volume and peak serum creatine kinase activity (r = 0.76 and r = 0.76, respectively; p less than 0.01)

  3. On the analysis of line profile variations: A statistical approach

    International Nuclear Information System (INIS)

    McCandliss, S.R.

    1988-01-01

    This study is concerned with the empirical characterization of the line profile variations (LPV), which occur in many of and Wolf-Rayet stars. The goal of the analysis is to gain insight into the physical mechanisms producing the variations. The analytic approach uses a statistical method to quantify the significance of the LPV and to identify those regions in the line profile which are undergoing statistically significant variations. Line positions and flux variations are then measured and subject to temporal and correlative analysis. Previous studies of LPV have for the most part been restricted to observations of a single line. Important information concerning the range and amplitude of the physical mechanisms involved can be obtained by simultaneously observing spectral features formed over a range of depths in the extended mass losing atmospheres of massive, luminous stars. Time series of a Wolf-Rayet and two of stars with nearly complete spectral coverage from 3940 angstrom to 6610 angstrom and with spectral resolution of R = 10,000 are analyzed here. These three stars exhibit a wide range of both spectral and temporal line profile variations. The HeII Pickering lines of HD 191765 show a monotonic increase in the peak rms variation amplitude with lines formed at progressively larger radii in the Wolf-Rayet star wind. Two times scales of variation have been identified in this star: a less than one day variation associated with small scale flickering in the peaks of the line profiles and a greater than one day variation associated with large scale asymmetric changes in the overall line profile shapes. However, no convincing period phenomena are evident at those periods which are well sampled in this time series

  4. A model of market power in electricity industries subject to peak load pricing

    International Nuclear Information System (INIS)

    Arellano, Maria-Soledad; Serra, Pablo

    2007-01-01

    This paper studies the exercise of market power in price-regulated electricity industries under peak-load pricing and merit order dispatching, but where investment decisions are taken by independent generating companies. Within this context, we show that producers can exercise market power by under-investing in base-load capacity, compared to the welfare-maximizing configuration. We also show that when there is free entry with an exogenous fixed entry cost that is later sunk, more intense competition results in higher welfare but fewer firms. (author)

  5. Seasonal variations of the high-latitude geomagnetic field intensity in the northern hemisphere

    International Nuclear Information System (INIS)

    Rivin, Yu.R.; Chkhaidze, Z.Sh.

    1994-01-01

    Seasonal variation of the geomagnetic field three components is investigated using the data of the USA observatories chain separately for polar region, auroral zone and middle latitudes beginning from 1950. The variation consists of an annual and half-yearly waves. main attention is paid to time variability of the annual wave phase in the auroral zone, that is connected with superposition of waves of western and eastern jets

  6. Variation of rain intensity and drop size distribution with General Weather Patterns (GWL)

    Science.gov (United States)

    Ghada, Wael; Buras, Allan; Lüpke, Marvin; Menzel, Annette

    2017-04-01

    Short-duration rainfall extremes may cause flash floods in certain catchments (e.g. cities or fast responding watersheds) and pose a great risk to affected communities. In order to predict their occurrence under future climate change scenarios, their link to atmospheric circulation patterns needs to be well understood. We used a comprehensive data set of meteorological data (temperature, rain gauge precipitation) and precipitation spectra measured by a disdrometer (OTT PARSIVEL) between October 2008 and June 2010 at Freising, southern Germany. For the 21 months of the study period, we integrated the disdrometer spectra over intervals of 10 minutes to correspond to the temporal resolution of the weather station data and discarded measurements with air temperatures below 0°C. Daily General Weather Patterns ("Großwetterlagen", GWL) were downloaded from the website of the German Meteorological Service. Out of the 29 GWL, 14 were included in the analysis for which we had at least 12 rain events during our study period. For the definition of a rain event, we tested different lengths of minimum inter-event times and chose 30 min as a good compromise between number and length of resulting events; rain events started when more than 0.001 mm/h (sensitivity of the disdrometer) were recorded. The length of the rain events ranged between 10 min and 28 h (median 130 min) with the maximum rain intensity recorded being 134 mm/h on 24-07-2009. Seasonal differences were identified for rain event average intensities and maximum intensities per event. The influence of GWL on rain properties such as rain intensity and drop size distribution per time step and per event was investigated based on the above mentioned rain event definition. Pairwise Wilcoxon-tests revealed that higher rain intensity and larger drops were associated with the GWL "Low over the British Isles" (TB), whereas low rain intensities and less drops per interval were associated with the GWL "High over Central Europe

  7. Ionization rates and harmonic generation for H interacting with laser pulses of λ = 1064 nm and peak intensities in the range 2 x 1013-2 x 1014 W cm-2

    International Nuclear Information System (INIS)

    Dionissopoulou, S.; Mercouris, Th.; Nicolaides, C.A.

    1996-01-01

    We applied the state-specific expansion approach (SSEA) to the solution of the time-dependent Schroedinger equation describing the interaction of H with laser pulses of λ = 1064 nm and peak intensities I 0 = 2 x 10 13 , 6 x 10 13 , 1 x 10 14 and 2 x 10 14 W cm -2 , and computed ionization rates and high-order harmonic spectra. For the first three cases, our results are compared with those of Krause and co-workers (Krause J L, Schafer K J and Kulander K C 1992 Phys. Rev. A45 3998) who employed the grid method. Whereas for I 0 = 1 x 10 14 W cm -2 convergence difficulties were reported for the grid method, no such difficulties were found for the SSEA. Given this fact, we tackled the problem of computing the harmonic spectrum for I 0 = 2 x 10 14 W cm -2 . This spectrum shows a cut-off at the 65th harmonic (3.17 U p + I p ) and an extended plateau containing low-intensity harmonics up to the 181st. The ionization rate is 1.7 x 10 13 s -1 while at the end of the pulse 19.5% of the system is in the 1s ground state and 2.6% in the bound states up to n = 20, l 19. (author)

  8. Physiological Responses During the Time Limit at 100% of the Peak Velocity in the Carminatti’s Test in Futsal Players

    Directory of Open Access Journals (Sweden)

    Floriano Leandro Teixeira

    2016-12-01

    Full Text Available The aim of this study was to investigate the physiological responses during the time limit at the intensity of the peak velocity of the Carminatti’s test (T-CAR. Ten professional futsal players (age, 27.4 ± 5.8 years, body mass, 78.8 ± 8.5 kg, body height, 175.8 ± 6.8 cm, body fat mass, 14.1 ± 2.6% took part in the study. The players performed three tests, with an interval of at least 48 hours, as follows: the T-CAR to determine the peak velocity and the maximal heart rate; an incremental treadmill protocol to determine the maximal physiological responses; and a time limit running test at the peak velocity reached in the T-CAR. During the last two tests, a portable gas analyzer was used for direct measurement of cardiorespiratory variables. It was shown that the peak velocity was not significantly different from the maximal aerobic speed achieved in the laboratory (p = 0.213. All athletes reached their maximum oxygen uptake during the time limit test. The maximum oxygen uptake achieved during the time limit test was not different from that observed in the laboratory condition (51.1 ± 4.7 vs. 49.6 ± 4.7 ml·kg-1·min-1, respectively, p = 0.100. In addition, Bland and Altman plots evidenced acceptable agreement between them. On average, athletes took ~140 s to achieve maximum oxygen uptake and maintained it for ~180 s. Therefore, the peak velocity intensity can be used as an indicator of maximal aerobic power of futsal athletes and the time limit can be used as a reference for training prescription.

  9. Boson peak of alkali and alkaline earth silicate glasses: influence of the nature and size of the network-modifying cation.

    Science.gov (United States)

    Richet, Nicolas F

    2012-01-21

    The influence of the size of the alkaline earth cation on the boson peak of binary metasilicate glasses, MSiO(3) (M = Mg, Ca, Sr, Ba), has been investigated from vibrational densities of states determined by inversion of low-temperature heat capacities. As given both by C(p)/T(3) and g(ω)/ω(2), the intensity of the boson peak undergoes a 7-fold increase from Mg to Ba, whereas its temperature and frequency correlatively decrease from 18 to 10 K and from 100 to 20 cm(-1), respectively. The boson peak results from a combination of librations of SiO(4) tetrahedra and localized vibrations of network-modifying cations with non-bridging oxygens whose contribution increases markedly with the ionic radius of the alkaline earth. As a function of ionic radii, the intensity for Sr and Ba varies in the same way as previously found for alkali metasilicate glasses. The localized vibrations involving alkali and heavy alkaline earth cations appear to be insensitive to the overall glass structure. Although the new data are coherent with an almost linear relationship between the temperature of the boson peak and transverse sound velocity, pure SiO(2) and SiO(2)-rich glasses make marked exceptions to this trend because of the weak transverse character of SiO(4) librations. Finally, the universality of the calorimetric boson peak is again borne out because all data for silicate glasses collapse on the same master curve when plotted in a reduced form (C(P)∕/T(3))/(C(P)/T(3))(b) vs. T/T(b). © 2012 American Institute of Physics

  10. Transport aloft drives peak ozone in the Mojave Desert

    Science.gov (United States)

    VanCuren, Richard

    2015-05-01

    Transport of anthropogenic pollution eastward out of the Los Angeles megacity region in California has been periodically observed to reach the Colorado River and the Colorado Plateau region beyond. In the 1980s, anthropogenic halocarbon tracers measured in and near the Las Angeles urban area and at a mountain-top site near the Colorado River, 400 km downwind, were shown to have a correlated seven-day cycle explainable by transport from the urban area with a time lag of 1-2 days. Recent short term springtime intensive studies using aircraft observations and regional modeling of long range transport of ozone from the Southern California megacity region showed frequent and persistent ozone impacts at surface sites across the Colorado Plateau and Southern Rocky Mountain region, at distances up to 1500 km, also with time lags of 1-2 days. However, the timing of ozone peaks at low altitude monitoring sites within the Mojave Desert, at distances from 100 to 400 km from the South Coast and San Joaquin Valley ozone source regions, does not show the expected time-lag behavior seen in the larger transport studies. This discrepancy is explained by recognizing ozone transport across the Mojave Desert to occur in a persistent layer of polluted air in the lower free troposphere with a base level at approximately 1 km MSL. This layer impacts elevated downwind sites directly, but only influences low altitude surface ozone maxima through deep afternoon mixing. Pollutants in this elevated layer derive from California source regions (the Los Angeles megacity region and the intensive agricultural region of the San Joaquin Valley), from long-range transport from Asia, and stratospheric down-mixing. Recognition of the role of afternoon mixing during spring and summer over the Mojave explains and expands the significance of previously published reports of ozone and other pollutants observed in and over the Mojave Desert, and resolves an apparent paradox in the timing of ozone peaks due to

  11. Peak Cardiorespiratory Responses of Patients with Subacute Stroke During Land and Aquatic Treadmill Exercise.

    Science.gov (United States)

    Lee, Yong Ki; Kim, Bo Ryun; Han, Eun Young

    2017-05-01

    The aim of this work was to investigate the cardiorespiratory responses of patients with subacute stroke to exercise stress tests with aquatic and land treadmills. Twenty-one consecutive patients who presented with first-ever subacute stroke in 2013-2015. All subjects underwent symptom-limited incremental exercise testing with aquatic and land treadmills. Land treadmill speed started at 1.5 km/h and increased 0.5 km/h every 1 to 2 minutes until maximal tolerable speed was achieved. Thereafter, the grade was elevated by 2% every 2 minutes. In the aquatic treadmill test, subjects were submerged to the xiphoid in 28°C water. Treadmill speed started at 1.5 km/h and was increased 0.5 km/h every 2 minutes thereafter. Cardiorespiratory responses were recorded with aquatic and land treadmills. Compared to land treadmill exercise, aquatic treadmill exercise achieved significantly better peak VO2 (22.0 vs 20.0; P = 0.02), peak metabolic equivalents (6.3 vs 5.8; P = 0.02), and peak rating of perceived exertion (17.6 vs 18.4, P = 0.01). Heart rate and VO2 correlated significantly during both tests (land treadmill: r = 0.96, P aquatic treadmill: r = 0.99, P Aquatic treadmill exercise elicited significantly better peak cardiorespiratory responses than land treadmill exercise and may be as effective for early intensive aerobic training in subacute stroke patients.

  12. Monitoring the deep western boundary current in the western North Pacific by echo intensity measured with lowered acoustic Doppler current profiler

    Science.gov (United States)

    Komaki, Kanae; Nagano, Akira

    2018-05-01

    Oxidation of iron and manganese ions is predominant in the oxygen-rich deep western boundary current (DWBC) within the Pacific Ocean. By the faster removal of particulate iron hydroxide and manganese oxide, densities of the particulate matters are considered to be lower in the DWBC than the interior region. To detect the density variation of suspended particles between the DWBC and interior regions, we analyzed echo intensity (EI) measured in the western North Pacific by hydrographic casts with a 300 kHz lowered acoustic Doppler current profiler (LADCP) in a whole water column. At depths greater than 3000 m ( 3000 dbar), EI is almost uniformly low between 12°N and 30°N but peaks sharply from 30°N to 35°N to a maximum north of 35°N. EI is found to be anomalously low in the DWBC compared to the background distribution. The DWBC pathways are identifiable by the low EI and high dissolved oxygen concentration. EI data by LADCPs and other acoustic instruments may be used to observe the temporal variations of the DWBC pathways.

  13. An adaptive model for vanadium redox flow battery and its application for online peak power estimation

    Science.gov (United States)

    Wei, Zhongbao; Meng, Shujuan; Tseng, King Jet; Lim, Tuti Mariana; Soong, Boon Hee; Skyllas-Kazacos, Maria

    2017-03-01

    An accurate battery model is the prerequisite for reliable state estimate of vanadium redox battery (VRB). As the battery model parameters are time varying with operating condition variation and battery aging, the common methods where model parameters are empirical or prescribed offline lacks accuracy and robustness. To address this issue, this paper proposes to use an online adaptive battery model to reproduce the VRB dynamics accurately. The model parameters are online identified with both the recursive least squares (RLS) and the extended Kalman filter (EKF). Performance comparison shows that the RLS is superior with respect to the modeling accuracy, convergence property, and computational complexity. Based on the online identified battery model, an adaptive peak power estimator which incorporates the constraints of voltage limit, SOC limit and design limit of current is proposed to fully exploit the potential of the VRB. Experiments are conducted on a lab-scale VRB system and the proposed peak power estimator is verified with a specifically designed "two-step verification" method. It is shown that different constraints dominate the allowable peak power at different stages of cycling. The influence of prediction time horizon selection on the peak power is also analyzed.

  14. Intensive lifestyle intervention improves cardiometabolic and exercise parameters in metabolically healthy obese and metabolically unhealthy obese individuals.

    Science.gov (United States)

    Dalzill, Claudie; Nigam, Anil; Juneau, Martin; Guilbeault, Valérie; Latour, Elise; Mauriège, Pascale; Gayda, Mathieu

    2014-04-01

    The effects of an intensive lifestyle intervention including Mediterranean diet nutritional counselling and high-intensity interval training (HIIT) on body composition, cardiometabolic, and exercise parameters were studied in metabolically unhealthy obese (NMHO) and metabolically healthy but obese (MHO) subjects. Fifty-five MHO (51 ± 8 years; waist circumference, 109 ± 13 cm) and 79 NMHO subjects (54 ± 9 years; waist circumference, 112 ± 13 cm) participated in an intensive lifestyle modification program based on Mediterranean diet nutritional counselling and HIIT 2-3 times per week. Body composition, cardiometabolic, and exercise parameters were measured at baseline and after 9 months. Initially, MHO patients had a lower blood pressure (BP), fasting glycemia, triglycerides, and a higher high-density lipoprotein cholesterol and peak oxygen uptake (VO2 peak) (P lifestyle program including Mediterranean diet nutritional counselling and HIIT is an appropriate intervention in MHO and NMHO subjects with similar potential clinical health benefits including an improved body composition, BP, fasting glycemia, insulin sensitivity, VO2 peak, and muscle endurance. Copyright © 2014 Canadian Cardiovascular Society. All rights reserved.

  15. Comparative study of boson peak in normal and secondary alcohols with terahertz time-domain spectroscopy

    International Nuclear Information System (INIS)

    Yomogida, Yoshiki; Sato, Yuki; Nozaki, Ryusuke; Mishina, Tomobumi; Nakahara, Jun'ichiro

    2010-01-01

    Using terahertz (THz) time-domain spectroscopy, we measured the complex permittivity of some normal (1-propanol, 1-butanol, and 1-pentanol) and secondary alcohols (2-propanol, 2-butanol, and 2-pentanol) in the frequency ranges from 0.2 to 2.5 THz at temperatures from 253 to 323 K. For all the samples, the complex permittivity in the THz region includes the following three components: (i) a high frequency side of dielectric relaxation processes, (ii) a broad mode around 1 THz, and (iii) a low frequency side of an intermolecular vibration mode located above 2.5 THz. The mode around 1 THz is recognized as a boson peak which is related to the local structure of disordered materials. The intensity of the boson peak in secondary alcohols is higher than that in normal alcohols. On the other hand, the number of carbon atoms slightly affects the appearance of the boson peak. These observations indicate that the position of an OH group in a molecule has a profound effect on the local structures in monohydric alcohols.

  16. Filling Service Gaps: Providing Intensive Treatment Services for Offenders

    Science.gov (United States)

    Young, Douglas W.; Farrell, Jill L.; Henderson, Craig E.; Taxman, Faye S.

    2009-01-01

    Consistent with the few studies that have previously examined treatment prevalence and access in the adult and juvenile justice systems, the recent National Criminal Justice Treatment Practices (NCJTP) survey indicated that there is a particular need to expand intensive treatment modalities for offenders in both institutional and community corrections settings. Applying multilevel modeling techniques to NCJTP survey data, this study explores conditions and factors that may underlie the wide variation among states in the provision of intensive treatment for offenders. Results indicate that states' overall rates of substance abuse and dependence, funding resources, and the state governor's political party affiliation were significantly associated with intensive treatment provision. Numerous factors that have been implicated in recent studies of evidence-based practice adoption, including state agency executives' views regarding rehabilitation, agency culture and climate, and other state-level measures (e.g., household income, crime rates, expenditures on treatment for the general population) were not associated with treatment provision. Future research should examine further variations in offenders' service needs, the role of legislators' political affiliations, and how other factors may interact with administrator characteristics in the adoption and expansion of intensive treatment services for offenders. PMID:19261394

  17. Automated asteroseismic peak detections

    Science.gov (United States)

    García Saravia Ortiz de Montellano, Andrés; Hekker, S.; Themeßl, N.

    2018-05-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible in a power density spectrum. Identification of oscillation modes is usually done by visual inspection that is time-consuming and has a degree of subjectivity. Here, we present a peak-detection algorithm especially suited for the detection of solar-like oscillations. It reliably characterizes the solar-like oscillations in a power density spectrum and estimates their parameters without human intervention. Furthermore, we provide a metric to characterize the false positive and false negative rates to provide further information about the reliability of a detected oscillation mode or the significance of a lack of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler.

  18. The Technical Integration of Remote Sensing and Geographical Information System to Predict the Peak Discharge Which Uses the Characteristic of Physical Environment of Catchments Area In Elo Sub Catchments Area in Central java

    Directory of Open Access Journals (Sweden)

    Sugiharto Budi Santoso

    2004-01-01

    The results of the research show that: (1 the aerial photo of black and white panchromatic on the scale 1:50. 000 is obtained to interpret the slope area and it is not good to interpret the accuracy of the covered arm is about 87% and 77,4 %, (2 the current coeflicient which is accounted hased on the table of Cook method is about 40,36% - deviates 39,94% from the field data; (3 the peak discharge in Elo sub catchments area with rational formula is about 3022,03 m/second, while the peak discharge as the observation result is about 112,675 m/second. Its large of research area causs the time to peak takes a long time, which causes raining intensity increases. The increasing value of raining intensity and the flow coeficient makes the value of peak discharge increases that larger than measured peak discharge.

  19. Continuous and high-intensity interval training: which promotes higher pleasure?

    Directory of Open Access Journals (Sweden)

    Bruno R R Oliveira

    Full Text Available OBJECTIVES: To compare the psychological responses to continuous (CT and high-intensity interval training (HIT sessions. METHODS: Fifteen men attended one CT session and one HIT session. During the first visit, the maximum heart rate, VO2Peak and respiratory compensation point (RCP were determined through a maximal cardiopulmonary exercise test. The HIT stimulus intensity corresponded to 100% of VO2Peak, and the average intensity of both sessions was maintained at 15% below the RCP. The order of the sessions was randomized. Psychological and physiological variables were recorded before, during and after each session. RESULTS: There were no significant differences between the average percentages of VO2 during the two exercise sessions (HIT: 73.3% vs. CT: 71.8%; p = 0.779. Lower responses on the feeling scale (p≤0.01 and higher responses on the felt arousal scale (p≤0.001 and the rating of perceived exertion were obtained during the HIT session. Despite the more negative feeling scale responses observed during HIT and a greater feeling of fatigue (measured by Profile of Mood States afterwards (p<0.01, the physical activity enjoyment scale was not significantly different between the two conditions (p = 0.779. CONCLUSION: Despite the same average intensity for both conditions, similar psychological responses under HIT and CT conditions were not observed, suggesting that the higher dependence on anaerobic metabolism during HIT negatively influenced the feeling scale responses.

  20. Study of power peak migration due to insertion of control bars in a PWR reactor

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Costa, Danilo Leite; Borges, Diogo da Silva; Lava, Deise Diana; Lima, Zelmo Rodrigues de; Moreira, Maria de Lourdes

    2014-01-01

    This paper aims to present a study on the power distribution behavior in a PWR reactor, considering the intensity and the migration of power peaks as is the insertion of control rods in the core banks. For this, the study of the diffusion of neutrons in the reactor was adopted by computer simulation that uses the finite difference method for numerically solving the neutron diffusion equation to two energy groups in steady state and in symmetry of a fourth quarter core. We decided to add the EPRI-9R 3D benchmark thermal-hydraulic parameters of a typical power PWR. With a new configuration for the reactor, the positions of the control rods banks were also modified. Due to the new positioning of these banks in the reactor, there was intense power gradients, favoring the occurrence of critical situations and logically unconventional for operation of a nuclear reactor. However, these facts have led interesting times for the study on the power distribution behavior in the reactor, showing axial migration of power peaks and mainly the effect of the geometry of the core on the latter. Based on the distribution of power was evident the increase of the power in elements located in the central region of the reactor core and, concomitantly, the reduction in elements of its periphery. Of course, the behavior exhibited by the simulated reactor is not in agreement with that expected in an actual reactor, where the insertion of control rods banks should lead to reduced power throughout the core as evenly as possible, avoiding sharp power peaks, standardizing the burning fuel, controlling reactivity deviations and acting in reactor shutdown

  1. Directional Wave Spectra Observed During Intense Tropical Cyclones

    Science.gov (United States)

    Collins, C. O.; Potter, H.; Lund, B.; Tamura, H.; Graber, H. C.

    2018-02-01

    Two deep-sea moorings were deployed 780 km off the coast of southern Taiwan for 4-5 months during the 2010 typhoon season. Directional wave spectra, wind speed and direction, and momentum fluxes were recorded on two Extreme Air-Sea Interaction buoys during the close passage of Severe Tropical Storm Dianmu and three tropical cyclones (TCs): Typhoon Fanapi, Super Typhoon Megi, and Typhoon Chaba. Conditions sampled include significant wave heights up to 11 m and wind speeds up to 26 m s-1. Details varied for large-scale spectral structure in frequency and direction but were mostly bimodal. The modes were generally composed of a swell system emanating from the most intense storm region and local wind-seas. The peak systems were consistently young, meaning actively forced by winds, when the storms were close. During the peaks of the most intense passages—Chaba at the northern mooring and Megi at the southern—the bimodal seas coalesced. During Chaba, the swell and wind-sea coupling directed the high frequency waves and the wind stress away from the wind direction. A spectral wave model was able reproduce many of the macrofeatures of the directional spectra.

  2. Post-peak metamorphic evolution of the Sumdo eclogite from the Lhasa terrane of southeast Tibet

    Science.gov (United States)

    Cao, Dadi; Cheng, Hao; Zhang, Lingmin; Wang, Ke

    2017-08-01

    A reconstruction of the pressure-temperature-time (P-T-t) path of high-pressure eclogite-facies rocks in subduction zones may reveal important information about the tectono-metamorphic processes that occur at great depths along the plate interface. The majority of studies have focused on prograde to peak metamorphism of these rocks, whereas after-peak metamorphism has received less attention. Herein, we present a detailed petrological, pseudosection modeling and radiometric dating study of a retrograded eclogite sample from the Sumdo ultrahigh pressure belt of the Lhasa terrane, Tibet. Mineral chemical variations, textural discontinuities and thermodynamic modeling suggest that the eclogite underwent an exhumation-heating period. Petrographic observations and phase equilibria modeling suggest that the garnet cores formed at the pressure peak (∼2.5 GPa and ∼520 °C) within the lawsonite eclogite-facies and garnet rims (∼1.5 GPa and spans an interval of ∼7 million years, which is a minimum estimate of the duration of the eclogite-facies metamorphism of the Sumdo eclogite.

  3. Use of the product of mean intensity ratio (PMIR) technique for discriminant analysis of lycopene-rich vegetable juice using a portable NIR-excited Raman spectrometer.

    Science.gov (United States)

    Hara, Risa; Ishigaki, Mika; Kitahama, Yasutaka; Ozaki, Yukihiro; Genkawa, Takuma

    2018-02-15

    In this study, a lycopene-content-based discriminant analysis was performed using a portable near-infrared-excited Raman spectrometer. In the vegetable-juice Raman spectra, the peak intensity of the lycopene band increased with increasing lycopene concentration, but scattering decreased the repeatability of the peak intensity. Consequently, developing a lycopene-concentration regression model using peak intensity is not straightforward. Therefore, a new method known as the product of mean intensity ratio (PMIR) analysis was developed to rapidly identify lycopene-rich samples on-site. In the PMIR analysis, Raman spectra are measured with short exposure times, confirming only the peaks of carotenoids with high concentrations, and thus the lycopene concentrations of vegetable juice samples could be determined successfully. Exposure times of 20ms and 100ms could detect lycopene concentrations of ≥5mg/100g and ≥2mg/100g with 93.2% and 97.7% accuracy, respectively; thus, lycopene-content-based discriminant analysis using the PMIR and a portable Raman spectrometer is feasible. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. LHC Report: Intensity ramp-up

    CERN Multimedia

    Mike Lamont for the LHC Team

    2012-01-01

    The first stable beams at 4 TeV were declared on Thursday, 5 April with 3 bunches per beam. This marked the start of the intensity ramp-up, which aims to get back up to 1380 bunches per beam as quickly as is safely possible.   The next couple of days saw fills with 47, 84 and 264 bunches per beam and on Sunday, 8 April the move was made to 624 bunches. With the squeeze to 60 cm in place, 624 bunches with reasonably high bunch intensities of around 1.3 to 1.4 x1011 protons per bunch have already yielded respectable peak luminosities of up to 2.5 x1033 cm-2s-1. Following a lot of hard work during the Christmas technical stop, machine availability is very good at the moment. The ramp-up in the number of bunches is accompanied by a series of checks aimed to make sure the machine protection systems and operational procedures are in a good enough shape to safely deal with the beam intensity. 624 bunches at 4 TeV already represents an energy over 50 MJ and serious damage potential. The next few days sh...

  5. Survey of elemental specificity in positron annihilation peak shapes

    Science.gov (United States)

    Myler, U.; Simpson, P. J.

    1997-12-01

    Recently the detailed interpretation of positron-annihilation γ-ray peak shapes has proven to be of interest with respect to their chemical specificity. In this contribution, we show highly resolved spectra for a number of different elements. To this purpose, annihilation spectra with strongly reduced background intensities were recorded in the two detector geometry, using a variable-energy positron beam. Division of the subsequently normalized spectra by a standard spectrum (in our case the spectrum of pure silicon) yields quotient spectra, which display features characteristic of the sample material. First we ascertain that the specific spectrum of an element is conserved in different chemical compounds, demonstrated here by identical oxygen spectra obtained from both SiO2/Si and MgO/Mg. Second, we show highly resolved spectra for a number of different elements (Fe...Zn, Ag, Ir...Au). We show that the characteristic features in these spectra vary in a systematic fashion with the atomic number of the element and can be tentatively identified with particular orbitals. Finally, for 26 different elements we compare the maximum intensity in the quotient spectra with the relative atomic density in the corresponding element. To our knowledge, this is the most comprehensive survey of such data made to date.

  6. Equatorial Precession Drove Mid-Latitude Changes in ENSO-Scale Variation in the Earliest Miocene

    Science.gov (United States)

    Fox, B.; D'Andrea, W. J.; Lee, D. E.; Wilson, G. S.

    2014-12-01

    Foulden Maar is an annually laminated lacustrine diatomite deposit from the South Island of New Zealand. The deposit was laid down over ~100 kyr of the latest Oligocene and earliest Miocene, during the peak and deglaciation phase of the Mi-1 Antarctic glaciation event. At this time, New Zealand was located at approximately the same latitude as today (~45°S). Evidence from organic geochemical proxies (δD, δ13C) and physical properties (density, colour) indicates the presence of an 11-kyr cycle at the site. Although it is known that 11-kyr insolation (half-precession) cycles occur between the Tropics, this cycle is rarely seen in sedimentary archives deposited outside the immediate vicinity of the Equator. Records from Foulden Maar correlate well with the amplitude and phase of the modelled equatorial half-precession cycle for the earliest Miocene. High-resolution (50 µm) colour intensity measurements and lamina thickness measurements both indicate the presence of significant ENSO-like (2-8 year) variation in the Foulden Maar sediments. Early results from targeted lamina thickness measurements suggest that ENSO-band variation is modulated by the 11-kyr cycle, with power in the ENSO band increasing during periods of increased insolation at the Equator. This implies that equatorial half-precession had a significant effect on ENSO-like variation in the early Miocene, and that this effect was felt as far afield as the mid-latitudes of the Southern Hemisphere.

  7. Determination of power peak factor using control rods, ex-core detectors and neural networks

    International Nuclear Information System (INIS)

    Souza, Rose Mary Gomes do Prado

    2005-01-01

    This work presents a methodology based on the artificial neural network technique to predict in real time the power peak factor in a form that can be implemented in reactor protection systems. The neural network inputs were those available in the reactor protection systems, namely, the axial and quadrant power differences obtained from measured ex-core detector signals, and the position of control rods. The response of ex core detector signals was measured in experiments especially performed in the IPEN/MB-01 zero-power reactor. Several reactor states with different power density distribution were obtained by positioning the control rods in different configurations. The power distribution and its peak factor were calculated for each of these reactor states using the Citation code. The obtained results show that the power peak factor correlates well with the control rod position and the quadrant power difference, and with a lesser degree with the axial power differences. The data presented an inherent organisation and could be classified into different classes of power peak factor behaviour as a function of position of control rods, axial power difference and quadrant power difference. The RBF networks were able to identify classes and interpolate the power peak factor values. The relative error for the power peak factor estimation ranged from 0.19 % to 0.67 %, less than the one that was obtained performing a power density distribution map with in-core detectors. It was observed that the positions of control rods bear the detailed and localised information about the power density distribution, and that the axial and the quadrant power difference describe its global variations in the axial and radial directions. The results showed that the RBF and MLP networks produced similar results, and that a neural network correlation can be implemented in power reactor protection systems. (author)

  8. Photoionization cross-section of donor impurity in spherical quantum dots under electric and intense laser fields

    International Nuclear Information System (INIS)

    Burileanu, L.M.

    2014-01-01

    Using a perturbative method we have investigated the behavior of the binding energy and photoionization cross-section of a donor impurity in spherical GaAs–GaAlAs quantum dots under the influence of electric and intense high-frequency laser fields. The dependencies of the binding energy and photoionization cross-section on electric and laser field strength, dot radius and impurity position were investigated. Our results show that the amplitude of photoionization cross-section grows with the dot radius increase and the peak of the cross-section blue shifts with the laser intensity increment. We have found that the binding energy is not a monotonically function of laser intensity: it decreases or increases depending on electric field regime. The studied effects are even more pronounced as the quantum dot radius is smaller. -- Highlights: • A photoionization cross-section study in quantum dots under laser and electric fields. • The photoionization cross-section peaks are red shifted by the electric field. • The photoionization cross-section peaks are blue shifted by the laser field. • The combined effects of applied fields strongly affect the binding energy

  9. Dependence of the muon intensity on the atmospheric temperature measured by the GRAPES-3 experiment

    Science.gov (United States)

    Arunbabu, K. P.; Ahmad, S.; Chandra, A.; Dugad, S. R.; Gupta, S. K.; Hariharan, B.; Hayashi, Y.; Jagadeesan, P.; Jain, A.; Jhansi, V. B.; Kawakami, S.; Kojima, H.; Mohanty, P. K.; Morris, S. D.; Nayak, P. K.; Oshima, A.; Rao, B. S.; Reddy, L. V.; Shibata, S.; Tanaka, K.; Zuberi, M.

    2017-09-01

    The large area (560 m2) GRAPES-3 tracking muon telescope has been operating uninterruptedly at Ooty, India since 2001. Every day, it records 4 × 109 muons of ≥1 GeV with an angular resolution of ∼4°. The variation of atmospheric temperature affects the rate of decay of muons produced by the galactic cosmic rays (GCRs), which in turn modulates the muon intensity. By analyzing the GRAPES-3 data of six years (2005-2010), a small (amplitude ∼0.2%) seasonal variation (1 year (Yr) period) in the intensity of muons could be measured. The effective temperature 'Teff' of the upper atmosphere also displays a periodic variation with an amplitude of ∼1 K which was responsible for the observed seasonal variation in the muon intensity. At GeV energies, the muons detected by the GRAPES-3 are expected to be anti-correlated with Teff. The anti-correlation between the seasonal variation of Teff, and the muon intensity was used to measure the temperature coefficient αT by fast Fourier transform (FFT) technique. The magnitude of αT was found to scale with the assumed attenuation length 'λ' of the hadrons in the range λ = 80-180 g cm-2. However, the magnitude of the correction in the muon intensity was found to be almost independent of the value of λ used. For λ = 120 g cm-2 the value of temperature coefficient αT was found to be (- 0.17 ± 0.02)% K-1.

  10. Diurnal variation of tropospheric temperature at a tropical station

    Directory of Open Access Journals (Sweden)

    K. Revathy

    2001-08-01

    Full Text Available The vertical velocity in the troposphere-lower stratosphere region measured using MST radar has been utilized to evaluate the temperature profile in the region. The diurnal variation of the tropospheric temperature on one day in August 1998 at the tropical station Gadanki (13.5° N, 79.2° E has been studied using the MST radar technique. The diurnal variation of the temperature revealed a prominent diurnal variation with the peak in the afternoon hours increasingly delayed in altitude. The tropopause temperature and altitude exhibited a clear diurnal cycle.Key words. Atmospheric composition and structure (pressure, density and temperature; troposphere - composition and chemistry; instruments and technique

  11. Using simulation to isolate physician variation in intensive care unit admission decision making for critically ill elders with end-stage cancer: a pilot feasibility study.

    Science.gov (United States)

    Barnato, Amber E; Hsu, Heather E; Bryce, Cindy L; Lave, Judith R; Emlet, Lillian L; Angus, Derek C; Arnold, Robert M

    2008-12-01

    To determine the feasibility of high-fidelity simulation for studying variation in intensive care unit admission decision making for critically ill elders with end-stage cancer. Mixed qualitative and quantitative analysis of physician subjects participating in a simulation scenario using hospital set, actors, medical chart, and vital signs tracings. The simulation depicted a 78-yr-old man with metastatic gastric cancer, life-threatening hypoxia most likely attributable to cancer progression, and stable preferences to avoid intensive care unit admission and intubation. Two independent raters assessed the simulations and subjects completed a postsimulation web-based survey and debriefing interview. Peter M. Winter Institute for Simulation Education and Research at the University of Pittsburgh. Twenty-seven hospital-based attending physicians, including 6 emergency physicians, 13 hospitalists, and 8 intensivists. Outcomes included qualitative report of clinical verisimilitude during the debriefing interview, survey-reported diagnosis and prognosis, and observed treatment decisions. Independent variables included physician demographics, risk attitude, and reactions to uncertainty. All (100%) reported that the case and simulation were highly realistic, and their diagnostic and prognostic assessments were consistent with our intent. Eight physicians (29.6%) admitted the patient to the intensive care unit. Among the eight physicians who admitted the patient to the intensive care unit, three (37%) initiated palliation, two (25%) documented the patient's code status (do not intubate/do not resuscitate), and one intubated the patient. Among the 19 physicians who did not admit the patient to the intensive care unit, 13 (68%) initiated palliation and 5 (42%) documented code status. Intensivists and emergency physicians (p = 0.048) were more likely to admit the patient to the intensive care unit. Years since medical school graduation were inversely associated with the

  12. "Peak-tracking chip" (PTC) for bulk refractive index sensing and bioarray sensing

    KAUST Repository

    Bougot-Robin, Kristelle; Austin, H. Robert; Benisty, Henri; Hsing, I-Ming; Kodzius, Rimantas; Li, Shunbo; Wen, Weijia; Zhang, Yinghua

    2013-01-01

    Resonant techniques are of wide interest to detect variation of effective refractive index at a chip surface. Both Surface Plasmon Resonance (SPR) and dielectric resonant waveguide (RWGs) can be exploited. Through their design, RWGs allow more flexibility (size of the biomolecule to detect, detection angle…). Using specially designed RWG “Peak-tracking chip”, we propose to use spatial information from a simple monochromatic picture as a new label-free bioarray technique. We discuss robustness, sensitivity, multiplex detection, fluidic integration of the technique and illustrate it through bulk refractive index sensing as well as specific recognition of DNA fragment from gyrase A.

  13. "Peak-tracking chip" (PTC) for bulk refractive index sensing and bioarray sensing

    KAUST Repository

    Bougot-Robin, Kristelle

    2013-10-20

    Resonant techniques are of wide interest to detect variation of effective refractive index at a chip surface. Both Surface Plasmon Resonance (SPR) and dielectric resonant waveguide (RWGs) can be exploited. Through their design, RWGs allow more flexibility (size of the biomolecule to detect, detection angle…). Using specially designed RWG “Peak-tracking chip”, we propose to use spatial information from a simple monochromatic picture as a new label-free bioarray technique. We discuss robustness, sensitivity, multiplex detection, fluidic integration of the technique and illustrate it through bulk refractive index sensing as well as specific recognition of DNA fragment from gyrase A.

  14. Hydrogen atom in intense magnetic field.

    Science.gov (United States)

    Canuto, V.; Kelly, D. C.

    1972-01-01

    The structure of a hydrogen atom situated in an intense magnetic field is investigaged. Three approaches are employed. An elementary Bohr picture establishes a crucial magnetic field strength, H sub a approximately equal to 5 x 10 to the 9th G. Fields in excess of H sub a are intense in that they are able to modify the characteristic atomic scales of length and binding energy. A second approach solves the Schrodinger equation by a combination of variational methods and perturbation theory. It yields analytic expressions for the wave functions and energy eigenvalues. A third approach determines the energy eigenvalues by reducing the Schrodinger equation to a one-dimensional wave equation, which is then solved numerically. Energy eigenvalues are tabulated for field strengths of 2 x 10 to the 10th G and 2 x 10 to the 12th G. It is found that at 2 x 10 to the 12th G the lowest energy eigenvalue is changed from -13.6 to about -180 eV in agreement with previous variational computations.

  15. Effects of high-intensity interval training on cardiometabolic risk factors in overweight/obese women.

    Science.gov (United States)

    Smith-Ryan, Abbie E; Trexler, Eric T; Wingfield, Hailee L; Blue, Malia N M

    2016-11-01

    The purpose of this study was to evaluate two practical interval training protocols on cardiorespiratory fitness, lipids and body composition in overweight/obese women. Thirty women (mean ± SD; weight: 88.1 ± 15.9 kg; BMI: 32.0 ± 6.0 kg · m(2)) were randomly assigned to ten 1-min high-intensity intervals (90%VO2 peak, 1 min recovery) or five 2-min high-intensity intervals (80-100% VO2 peak, 1 min recovery) or control. Peak oxygen uptake (VO2 peak), peak power output (PPO), body composition and fasting blood lipids were evaluated before and after 3 weeks of training, completed 3 days per week. Results from ANCOVA analyses demonstrated no significant training group differences for any primary variables (P > 0.05). When training groups were collapsed, 1MIN and 2MIN resulted in a significant increase in PPO (∆18.9 ± 8.5 watts; P = 0.014) and time to exhaustion (∆55.1 ± 16.4 s; P = 0.001); non-significant increase in VO2 peak (∆2.36 ± 1.34 ml · kg(-)(1) · min(-)(1); P = 0.185); and a significant decrease in fat mass (FM) (-∆1.96 ± 0.99 kg; P = 0.011). Short-term interval exercise training may be effective for decreasing FM and improving exercise tolerance in overweight and obese women.

  16. An Improvement on the Junction Temperature Measurement of Light-Emitting Diodes by using the Peak Shift Method Compared with the Forward Voltage Method

    International Nuclear Information System (INIS)

    He Su-Ming; Wang Jin-Bin; Luo Xiang-Dong; Zhang Bo; Fu Lei; Cheng Li-Wen; Lu Wei

    2012-01-01

    The junction temperature of red, green and blue high power light emitting diodes (LEDs) is measured by using the emission peak shift method and the forward voltage method. Both the emission peak shift and the forward voltage decrease show a linear relationship relative to junction temperature. The linear coefficients of the red, green and blue LEDs for the peak shift method and the forward voltage method range from 0.03 to 0.15 nm/°C and from 1.33 to 3.59 mV/°C, respectively. Compared with the forward voltage method, the peak shift method is almost independent of bias current and sample difference. The variation of the slopes is less than 2% for the peak shift method and larger than 30% for the forward voltage method, when the LEDs are driven by different bias currents. It is indicated that the peak shift method gives better stability than the forward voltage method under different LED working conditions

  17. High-intensity cycle interval training improves cycling and running performance in triathletes.

    Science.gov (United States)

    Etxebarria, Naroa; Anson, Judith M; Pyne, David B; Ferguson, Richard A

    2014-01-01

    Effective cycle training for triathlon is a challenge for coaches. We compared the effects of two variants of cycle high-intensity interval training (HIT) on triathlon-specific cycling and running. Fourteen moderately-trained male triathletes ([Formula: see text]O2peak 58.7 ± 8.1 mL kg(-1) min(-1); mean ± SD) completed on separate occasions a maximal incremental test ([Formula: see text]O2peak and maximal aerobic power), 16 × 20 s cycle sprints and a 1-h triathlon-specific cycle followed immediately by a 5 km run time trial. Participants were then pair-matched and assigned randomly to either a long high-intensity interval training (LONG) (6-8 × 5 min efforts) or short high-intensity interval training (SHORT) (9-11 × 10, 20 and 40 s efforts) HIT cycle training intervention. Six training sessions were completed over 3 weeks before participants repeated the baseline testing. Both groups had an ∼7% increase in [Formula: see text]O2peak (SHORT 7.3%, ±4.6%; mean, ±90% confidence limits; LONG 7.5%, ±1.7%). There was a moderate improvement in mean power for both the SHORT (10.3%, ±4.4%) and LONG (10.7%, ±6.8%) groups during the last eight 20-s sprints. There was a small to moderate decrease in heart rate, blood lactate and perceived exertion in both groups during the 1-h triathlon-specific cycling but only the LONG group had a substantial decrease in the subsequent 5-km run time (64, ±59 s). Moderately-trained triathletes should use both short and long high-intensity intervals to improve cycling physiology and performance. Longer 5-min intervals on the bike are more likely to benefit 5 km running performance.

  18. Testing the FOODBANCS hypothesis: Seasonal variations in near-bottom particle flux, bioturbation intensity, and deposit feeding based on 234Th measurements

    Science.gov (United States)

    McClintic, Mark A.; DeMaster, David J.; Thomas, Carrie J.; Smith, Craig R.

    2008-11-01

    Naturally occurring 234Th (24-d half-life) was used on the West Antarctic continental shelf to evaluate temporal variations in the flux of particulate material reaching the seabed, bioturbation intensity, the seasonal continuity of feeding by benthic fauna, and trends in particle selection during ingestion for six common detritivores (four surface deposit feeders and two subsurface deposit feeders). These measurements were made at three stations during the five FOODBANCS cruises (December 1999, March, June, and October 2000, and March 2001) to assess the nature of pelagic-benthic coupling on the shelf and to evaluate the seabed as a potential food bank for deposit feeders when surface primary production is minimal. Two summer regimes were sampled (March 2000 and March 2001) with the latter exhibiting a distinct 1-2-cm-thick phytodetritus layer in nearly all sediment core samples. At site B, the 234Th fluxes into the near-bottom (150/170 mab) sediment traps were indistinguishable for the December-March 2000, March-June 2000, and June-October 2000 sampling intervals (fluxes ranging from 170 to 280 dpm m -2 d -1). However, the sediment-trap 234Th flux measured for the October 2000-March 2001 interval (1000 dpm m -2 d -1) was ˜5-fold greater than during the other three sampling periods, consistent with the deposition of a phytodetritus layer. The steady-state 234Th fluxes derived from seabed inventories at site B were 2.4-2.7 times greater than the sediment-trap 234Th fluxes, indicating substantial scavenging of this particle-reactive radiotracer in the bottom 150 m of the water column and/or lateral transport near the seabed. The seabed 234Th inventories at the three stations showed no variation during the first four cruises, but were significantly greater during cruise FB-V (March 2001), when the phytodetritus layer occurred. Based on 234Th distributions in the seabed, bioturbation intensities (quantified using the diffusive mixing coefficient, Db) varied from 0

  19. High-intensity interval training and athletic performance in Taekwondo athletes.

    Science.gov (United States)

    Monks, Lynne; Seo, Myong-Won; Kim, Hyun-Bae; Jung, Hyun C; Song, Jong K

    2017-10-01

    The purpose of this study was to determine the effects of high-intensity interval training (HIIT) on athletic performance in Taekwondo athletes. Thirty-three male and female collegiate Taekwondo athletes were randomly divided into a HIIT group (N.=16) or a high-intensity continuous running (HICR) group (N.=17). The HIIT group undertook training of high-intensity sprints interspersed with active rest periods whilst the HICR group participated in high-intensity running for a continuous period. Both groups completed 11 sessions over 4 weeks. Physique, body composition, Wingate anaerobic test and VO2max test were measured. The vertical jump test, agility T-test and sit-ups were used to assess physical fitness. Repeated measures ANCOVAs with sex as a covariate were applied and significant level was set at 0.05. Following 11 sessions of training, significant improvements in anaerobic peak power (Ptraining, specifically the influence of training intensity on anaerobic capacity.

  20. Noise pollution levels in the pediatric intensive care unit.

    Science.gov (United States)

    Kramer, Bree; Joshi, Prashant; Heard, Christopher

    2016-12-01

    Patients and staff may experience adverse effects from exposure to noise. This study assessed noise levels in the pediatric intensive care unit and evaluated family and staff opinion of noise. Noise levels were recorded using a NoisePro DLX. The microphone was 1 m from the patient's head. The noise level was averaged each minute and levels above 70 and 80 dBA were recorded. The maximum, minimum, and average decibel levels were calculated and peak noise level great than 100 dBA was also recorded. A parent questionnaire concerning their evaluation of noisiness of the bedside was completed. The bedside nurse also completed a questionnaire. The average maximum dB for all patients was 82.2. The average minimum dB was 50.9. The average daily bedside noise level was 62.9 dBA. The average % time where the noise level was higher than 70 dBA was 2.2%. The average percent of time that the noise level was higher than 80 dBA was 0.1%. Patients experienced an average of 115 min/d where peak noise was greater than 100 dBA. The parents and staff identified the monitors as the major contribution to noise. Patients experienced levels of noise greater than 80 dBA. Patients experience peak noise levels in excess of 100 dB during their pediatric intensive care unit stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. On calculating intensity from XPS spectra

    International Nuclear Information System (INIS)

    Vegh, Janos

    2006-01-01

    The intensity calculation is the basis for all quantitative applications of electron spectroscopy. Unfortunately, some misinterpreted terms are used and correctly interpreted terms are misused in the overwhelming majority of publications in XPS, including most textbooks as well as accepted and proposed standards. Due to this mistake the number of the detected electrons is given as having dimension of energy (?) and also the formulas for calculating the peak area and its standard deviation are wrong. Since in all other spectroscopic fields the number of the detected particles is dimensionless, continuing this practice leads to isolating XPS from both other measurement sciences and theory, because the measured total intensity in XPS is simply not comparable to the ones derived with other spectroscopic methods or theoretically. Therefore, the basic measuring processes and terms are critically reviewed and their physically correct interpretation is given. This interpretation reveals that the error is hidden in the incorrect interpretation of both the measurement process and the measured quantity. It is shown that through using the correct interpretation both the dimensions of the intensity calculated from electron spectroscopic measurements as well as the formulas related to the intensity and its standard deviation will agree with all other spectroscopic fields

  2. Method and apparatus for current-output peak detection

    Science.gov (United States)

    De Geronimo, Gianluigi

    2017-01-24

    A method and apparatus for a current-output peak detector. A current-output peak detector circuit is disclosed and works in two phases. The peak detector circuit includes switches to switch the peak detector circuit from the first phase to the second phase upon detection of the peak voltage of an input voltage signal. The peak detector generates a current output with a high degree of accuracy in the second phase.

  3. Galactic cosmic-ray intensity to a heliocentric distance of 18 AU

    International Nuclear Information System (INIS)

    Van Allen, J.A.

    1980-01-01

    An updated report is given of observations of galactic cosmic-ray intensity to heliocentric radial distance of 8.6 and 18.4 AU with Pioneer 11 and Pioneer 10, respectively. Solar activity via the magnetic structure of the interplanetary medium continues to modulate the intensity out to the greatest distance reached thus far. During the 7 year period 1972 March to 1979 March, the galactic cosmic-ray intensity E/sub p/>80 MeV as measured by detectors on Pioneers 10 and 11 exhibited aperiodic temporal variations by about a factor of 2 and on a time scale of the order of a year and quasi-persistent cyclic variations of 26 day period and amplitude a few percent. The former are attributed to overall changes in the magnetic field structure of the heliosphere, the latter to fast-slow solar wind streams in and near the ecliptic plane and not to toward-away magnetic field sectors. The apparent heliographic latitude dependence of intensity is 0( +- 1.5)% per 10 0 in the latitude range +7 0 .7 to +15. 0 8, though it is possible that radially dependent temporal variations over the large difference in the heliocentric radial distances of the two spacecraft may make this result of limited significance. For protons of energy E/sub p/>80 MeV, there is a fairly consistent heliocentric radial gradient of +2.1( +- 0.3)% per AU integral intensity until 1978 April--May, at which time a substantial disruption of the distribution of cosmic rays in the heliosphere occurred

  4. Gamma-Ray Peak Integration: Accuracy and Precision

    International Nuclear Information System (INIS)

    Richard M. Lindstrom

    2000-01-01

    The accuracy of singlet gamma-ray peak areas obtained by a peak analysis program is immaterial. If the same algorithm is used for sample measurement as for calibration and if the peak shapes are similar, then biases in the integration method cancel. Reproducibility is the only important issue. Even the uncertainty of the areas computed by the program is trivial because the true standard uncertainty can be experimentally assessed by repeated measurements of the same source. Reproducible peak integration was important in a recent standard reference material certification task. The primary tool used for spectrum analysis was SUM, a National Institute of Standards and Technology interactive program to sum peaks and subtract a linear background, using the same channels to integrate all 20 spectra. For comparison, this work examines other peak integration programs. Unlike some published comparisons of peak performance in which synthetic spectra were used, this experiment used spectra collected for a real (though exacting) analytical project, analyzed by conventional software used in routine ways. Because both components of the 559- to 564-keV doublet are from 76 As, they were integrated together with SUM. The other programs, however, deconvoluted the peaks. A sensitive test of the fitting algorithm is the ratio of reported peak areas. In almost all the cases, this ratio was much more variable than expected from the reported uncertainties reported by the program. Other comparisons to be reported indicate that peak integration is still an imperfect tool in the analysis of gamma-ray spectra

  5. The Mucosal Immune Function Is Not Compromised during a Period of High-Intensity Interval Training. Is It Time to Reconsider an Old Assumption?

    Science.gov (United States)

    Born, Dennis-Peter; Zinner, Christoph; Sperlich, Billy

    2017-01-01

    Purpose: The aim of the study was to evaluate the mucosal immune function and circadian variation of salivary cortisol, Immunoglobin-A (sIgA) secretion rate and mood during a period of high-intensity interval training (HIIT) compared to long-slow distance training (LSD). Methods: Recreational male runners (n = 28) completed nine sessions of either HIIT or LSD within 3 weeks. The HIIT involved 4 × 4 min of running at 90–95% of maximum heart rate interspersed with 3 min of active recovery while the LSD comprised of continuous running at 70–75% of maximum heart rate for 60–80 min. The psycho-immunological stress-response was investigated with a full daily profile of salivary cortisol and immunoglobin-A (sIgA) secretion rate along with the mood state on a baseline day, the first and last day of training and at follow-up 4 days after the last day of training. Before and after the training period, each athlete's running performance and peak oxygen uptake (V·O2peak) was determined with an incremental exercise test. Results: The HIIT resulted in a longer time-to-exhaustion (P = 0.02) and increased V·O2peak compared to LSD (P = 0.01). The circadian variation of sIgA secretion rate showed highest values in the morning immediately after waking up followed by a decrease throughout the day in both groups (P HIIT, the wake-up response of sIgA secretion rate was higher on the last day of training (P HIIT and LSD (P HIIT indicates no compromised mucosal immune function compared to LSD and shows the functional adaptation of the mucosal immune system in response to the increased stress and training load of nine sessions of HIIT. PMID:28744226

  6. On the Scaling Law for Broadband Shock Noise Intensity in Supersonic Jets

    Science.gov (United States)

    Kanudula, Max

    2009-01-01

    A theoretical model for the scaling of broadband shock noise intensity in supersonic jets was formulated on the basis of linear shock-shear wave interaction. An hypothesis has been postulated that the peak angle of incidence (closer to the critical angle) for the shear wave primarily governs the generation of sound in the interaction process rather than the noise generation contribution from off-peak incident angles. The proposed theory satisfactorily explains the well-known scaling law for the broadband shock -associated noise in supersonic jets.

  7. Temporal variation of erythemally effective UVB/UVA ratio at Chilton, UK

    International Nuclear Information System (INIS)

    Hooke, R. J.; Pearson, A. J.; O'Hagan, J. B.

    2012-01-01

    An analysis of the temporal variation in the erythemally weighted UVB/UVA irradiance ratio using spectral data collected from a monitoring site in Chilton, UK (51 deg. N) for the 5-y period from 2004 to 2008 is presented. The variation in the diurnal ratio was found to be bell-shaped, with minima on average 1 h after sunrise and before sunset. The minima were found to be indicative of the point at which UVB becomes undetectable by the spectro-radiometer and therefore the outer boundary of useful data. A potential flaw entailed in the erythemal weighting of low-level spectral UV data is described. The peak daily ratio value was found to have a bell-shaped distribution over the course of a year with a maximum in July rather than at the summer solstice-a result explained by the ozone cycle. The peak daily ratio was found to vary by a factor of 4 over the course of the year; this range of variation was also found to occur over a single day in the summer. (authors)

  8. When intensions do not map onto extensions: Individual differences in conceptualization.

    Science.gov (United States)

    Hampton, James A; Passanisi, Alessia

    2016-04-01

    Concepts are represented in the mind through knowledge of their extensions (the class of items to which the concept applies) and intensions (features that distinguish that class of items). A common assumption among theories of concepts is that the 2 aspects are intimately related. Hence if there is systematic individual variation in concept representation, the variation should correlate between extensional and intensional measures. A pair of individuals with similar extensional beliefs about a given concept should also share similar intensional beliefs. To test this notion, exemplars (extensions) and features (intensions) of common categories were rated for typicality and importance respectively across 2 occasions. Within-subject consistency was greater than between-subjects consensus on each task, providing evidence for systematic individual variation. Furthermore, the similarity structure between individuals for each task was stable across occasions. However, across 5 samples, similarity between individuals for extensional judgments did not map onto similarity between individuals for intensional judgments. The results challenge the assumption common to many theories of conceptual representation that intensions determine extensions and support a hybrid view of concepts where there is a disconnection between the conceptual resources that are used for the 2 tasks. (c) 2016 APA, all rights reserved).

  9. Polarized training has greater impact on key endurance variables than threshold, high intensity or high volume training

    Directory of Open Access Journals (Sweden)

    Thomas eStöggl

    2014-02-01

    Full Text Available Endurance athletes integrate four conditioning concepts in their training programs: high-volume training (HVT, ‘threshold-training’ (THR, high-intensity interval training (HIIT and a combination of these aforementioned concepts known as polarized training (POL. The purpose of this study was to explore which of these four training concepts provides the greatest response on key components of endurance performance in well-trained endurance athletes. Methods: Forty eight runners, cyclists, triathletes and cross-country skiers (peak oxygen uptake: (VO2peak: 62.6±7.1 mL∙min-1∙kg-1 were randomly assigned to one of four groups performing over nine weeks. An incremental test, work economy and a VO2peak tests were performed. Training intensity was heart rate controlled. Results: POL demonstrated the greatest increase in VO2peak (+6.8 ml∙min∙kg-1 or 11.7%, P0.05. Conclusion: POL resulted in the greatest improvements in most key variables of endurance performance in well-trained endurance athletes. THR or HVT did not lead to further improvements in performance related variables.

  10. Seasonal variation in sports participation.

    Science.gov (United States)

    Schüttoff, Ute; Pawlowski, Tim

    2018-02-01

    This study explores indicators describing socio-demographics, sports participation characteristics and motives which are associated with variation in sports participation across seasons. Data were drawn from the German Socio-Economic Panel which contains detailed information on the sports behaviour of adults in Germany. Overall, two different measures of seasonal variation are developed and used as dependent variables in our regression models. The first variable measures the coefficient of (seasonal) variation in sport-related energy expenditure per week. The second variable measures whether activity drops below the threshold as defined by the World Health Organization (WHO). Results suggest that the organisational setting, the intensity and number of sports practised, and the motive for participation are strongly correlated with the variation measures used. For example, both, participation in a sports club and a commercial facility, are associated with reduced seasonal variation and a significantly higher probability of participating at a volume above the WHO threshold across all seasons. These findings give some impetus for policymaking and the planning of sports programmes as well as future research directions.

  11. Anatomic variation and orgasm: Could variations in anatomy explain differences in orgasmic success?

    Science.gov (United States)

    Emhardt, E; Siegel, J; Hoffman, L

    2016-07-01

    Though the public consciousness is typically focused on factors such as psychology, penis size, and the presence of the "G-spot," there are other anatomical and neuro-anatomic differences that could play an equal, or more important, role in the frequency and intensity of orgasms. Discovering these variations could direct further medical or procedural management to improve sexual satisfaction. The aim of this study is to review the available literature of anatomical sexual variation and to explain why this variation may predispose some patients toward a particular sexual experience. In this review, we explored the available literature on sexual anatomy and neuro-anatomy. We used PubMed and OVID Medline for search terms, including orgasm, penile size variation, clitoral variation, Grafenberg spot, and benefits of orgasm. First we review the basic anatomy and innervation of the reproductive organs. Then we describe several anatomical variations that likely play a superior role to popular known variation (penis size, presence of g-spot, etc). For males, the delicate play between the parasympathetic and sympathetic nervous systems is vital to achieve orgasm. For females, the autonomic component is more complex. The clitoris is the primary anatomical feature for female orgasm, including its migration toward the anterior vaginal wall. In conclusions, orgasms are complex phenomena involving psychological, physiological, and anatomic variation. While these variations predispose people to certain sexual function, future research should explore how to surgically or medically alter these. Clin. Anat. 29:665-672, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Ambiguities in the classification of cochin estuary, West coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Shivaprasad, A.; Vinita, J.; Revichandran, C.; Manoj, N.T.; Jayalakshmy, K.V.; Muraleedharan, K.R

    by monsoonal spells causing intense flushing. During the peak dry period, the runoff is less but steady providing a stable environment. River runoff is controlled by short term variations rather than long term variations. Using large comprehensive data sets...

  13. Differential Motor Unit Changes after Endurance or High-Intensity Interval Training.

    Science.gov (United States)

    Martinez-Valdes, Eduardo; Falla, Deborah; Negro, Francesco; Mayer, Frank; Farina, Dario

    2017-06-01

    Using a novel technique of high-density surface EMG decomposition and motor unit (MU) tracking, we compared changes in the properties of vastus medialis and vastus lateralis MU after endurance (END) and high-intensity interval training (HIIT). Sixteen men were assigned to the END or the HIIT group (n = 8 each) and performed six training sessions for 14 d. Each session consisted of 8-12 × 60-s intervals at 100% peak power output separated by 75 s of recovery (HIIT) or 90-120 min continuous cycling at ~65% V˙O2peak (END). Pre- and postintervention, participants performed 1) incremental cycling to determine V˙O2peak and peak power output and 2) maximal, submaximal (10%, 30%, 50%, and 70% maximum voluntary contraction [MVC]), and sustained (until task failure at 30% MVC) isometric knee extensions while high-density surface EMG signals were recorded from the vastus medialis and vastus lateralis. EMG signals were decomposed (submaximal contractions) into individual MU by convolutive blind source separation. Finally, MU were tracked across sessions by semiblind source separation. After training, END and HIIT improved V˙O2peak similarly (by 5.0% and 6.7%, respectively). The HIIT group showed enhanced maximal knee extension torque by ~7% (P = 0.02) and was accompanied by an increase in discharge rate for high-threshold MU (≥50% knee extension MVC) (P 0.05). HIIT and END induce different adjustments in MU discharge rate despite similar improvements in cardiopulmonary fitness. Moreover, the changes induced by HIIT are specific for high-threshold MU. For the first time, we show that HIIT and END induce specific neuromuscular adaptations, possibly related to differences in exercise load intensity and training volume.

  14. X-ray Emission Spectrum of Liquid Ethanol: Origin of Split Peaks.

    Science.gov (United States)

    Takahashi, Osamu; Ljungberg, Mathias P; Pettersson, Lars G M

    2017-12-14

    The X-ray emission spectrum of liquid ethanol was calculated using density functional theory and a semiclassical approximation to the Kramers-Heisenberg formula including core-hole-induced dynamics. Our spectrum agrees well with the experimental spectrum. We found that the intensity ratio between the two peaks at 526 and 527 eV assigned as 10a' and 3a″ depends not only on the hydrogen bonding network around the target molecule but also on the intramolecular conformation. This effect is absent in liquid methanol and demonstrates the high sensitivity of X-ray emission to molecular structure. The dependence of spectral features on hydrogen-bonding as well as on dynamical effects following core excitation are also discussed.

  15. Isometric strength training lowers the O2 cost of cycling during moderate-intensity exercise.

    Science.gov (United States)

    Zoladz, Jerzy A; Szkutnik, Zbigniew; Majerczak, Joanna; Grandys, Marcin; Duda, Krzysztof; Grassi, Bruno

    2012-12-01

    The effect of maximal voluntary isometric strength training of knee extensor muscles on pulmonary V'O(2) on-kinetics, the O(2) cost of cycling and peak oxygen uptake (V'O(2peak)) in humans was studied. Seven healthy males (mean ± SD, age 22.3 ± 2.0 years, body weight 75.0 ± 9.2 kg, V'O(2peak) 49.5 ± 3.8 ml kg(-1) min(-1)) performed maximal isometric strength training lasting 7 weeks (4 sessions per week). Force during maximal voluntary contraction (MVC) increased by 15 % (P Strength training resulted in a significant decrease (by ~7 %; P Isometric strength training rapidly (i.e., after 1 week) decreases the O(2) cost of cycling during moderate-intensity exercise, whereas it does not affect the amplitude of the slow component of the V'O(2) on-kinetics during heavy-intensity exercise. Isometric strength training can have beneficial effects on performance during endurance events.

  16. Climatology and Interannual Variability of Quasi-Global Intense Precipitation Using Satellite Observations

    Science.gov (United States)

    Ricko, Martina; Adler, Robert F.; Huffman, George J.

    2016-01-01

    Climatology and variations of recent mean and intense precipitation over a near-global (50 deg. S 50 deg. N) domain on a monthly and annual time scale are analyzed. Data used to derive daily precipitation to examine the effects of spatial and temporal coverage of intense precipitation are from the current Tropical Rainfall Measuring Mission (TRMM) Multisatellite Precipitation Analysis (TMPA) 3B42 version 7 precipitation product, with high spatial and temporal resolution during 1998 - 2013. Intense precipitation is defined by several different parameters, such as a 95th percentile threshold of daily precipitation, a mean precipitation that exceeds that percentile, or a fixed threshold of daily precipitation value [e.g., 25 and 50 mm day(exp -1)]. All parameters are used to identify the main characteristics of spatial and temporal variation of intense precipitation. High correlations between examined parameters are observed, especially between climatological monthly mean precipitation and intense precipitation, over both tropical land and ocean. Among the various parameters examined, the one best characterizing intense rainfall is a fraction of daily precipitation Great than or equal to 25 mm day(exp. -1), defined as a ratio between the intense precipitation above the used threshold and mean precipitation. Regions that experience an increase in mean precipitation likely experience a similar increase in intense precipitation, especially during the El Nino Southern Oscillation (ENSO) events. Improved knowledge of this intense precipitation regime and its strong connection to mean precipitation given by the fraction parameter can be used for monitoring of intense rainfall and its intensity on a global to regional scale.

  17. Relationships between electroencephalographic spectral peaks across frequency bands

    Directory of Open Access Journals (Sweden)

    Sacha Jennifer Van Albada

    2013-03-01

    Full Text Available The degree to which electroenencephalographic (EEG spectral peaks are independent, and the relationships between their frequencies have been debated. A novel fitting method was used to determine peak parameters in the range 2–35 Hz from a large sample of eyes-closed spectra, and their interrelationships were investigated. Findings were compared with a mean-field model of thalamocortical activity, which predicts near-harmonic relationships between peaks. The subject set consisted of 1424 healthy subjects from the Brain Resource International Database. Peaks in the theta range occurred on average near half the alpha peak frequency, while peaks in the beta range tended to occur near twice and three times the alpha peak frequency on an individual-subject basis. Moreover, for the majority of subjects, alpha peak frequencies were significantly positively correlated with frequencies of peaks in the theta and low and high beta ranges. Such a harmonic progression agrees semiquantitatively with theoretical predictions from the mean-field model. These findings indicate a common or analogous source for different rhythms, and help to define appropriate individual frequency bands for peak identification.

  18. Relationships between Electroencephalographic Spectral Peaks Across Frequency Bands

    Science.gov (United States)

    van Albada, S. J.; Robinson, P. A.

    2013-01-01

    The degree to which electroencephalographic spectral peaks are independent, and the relationships between their frequencies have been debated. A novel fitting method was used to determine peak parameters in the range 2–35 Hz from a large sample of eyes-closed spectra, and their interrelationships were investigated. Findings were compared with a mean-field model of thalamocortical activity, which predicts near-harmonic relationships between peaks. The subject set consisted of 1424 healthy subjects from the Brain Resource International Database. Peaks in the theta range occurred on average near half the alpha peak frequency, while peaks in the beta range tended to occur near twice and three times the alpha peak frequency on an individual-subject basis. Moreover, for the majority of subjects, alpha peak frequencies were significantly positively correlated with frequencies of peaks in the theta and low and high beta ranges. Such a harmonic progression agrees semiquantitatively with theoretical predictions from the mean-field model. These findings indicate a common or analogous source for different rhythms, and help to define appropriate individual frequency bands for peak identification. PMID:23483663

  19. Hubbert's Peak -- A Physicist's View

    Science.gov (United States)

    McDonald, Richard

    2011-04-01

    Oil, as used in agriculture and transportation, is the lifeblood of modern society. It is finite in quantity and will someday be exhausted. In 1956, Hubbert proposed a theory of resource production and applied it successfully to predict peak U.S. oil production in 1970. Bartlett extended this work in publications and lectures on the finite nature of oil and its production peak and depletion. Both Hubbert and Bartlett place peak world oil production at a similar time, essentially now. Central to these analyses are estimates of total ``oil in place'' obtained from engineering studies of oil reservoirs as this quantity determines the area under the Hubbert's Peak. Knowing the production history and the total oil in place allows us to make estimates of reserves, and therefore future oil availability. We will then examine reserves data for various countries, in particular OPEC countries, and see if these data tell us anything about the future availability of oil. Finally, we will comment on synthetic oil and the possibility of carbon-neutral synthetic oil for a sustainable future.

  20. Spatial Splitting and Intensity Suppression of Four-Wave Mixing in V-Type Three-Level Atomic System

    International Nuclear Information System (INIS)

    Chuang-She, Li; Wei-Tao, Yin; Chen-Zhi, Yuan; Mei-Zhen, Shi; Yan, Zhao; Yan-Peng, Zhang

    2010-01-01

    We illustrate our experimental observation of coexisting the controllable spatial splitting and intensity suppression of four-wave mixing (FWM) beam in a V-type three-level atomic system. The peak number and separation distance of the FWM beam are controlled by the intensities and frequencies of the laser beams, as well as atomic density