WorldWideScience

Sample records for pattern determine mass

  1. Outcome prediction in pneumonia induced ALI/ARDS by clinical features and peptide patterns of BALF determined by mass spectrometry.

    Science.gov (United States)

    Frenzel, Jochen; Gessner, Christian; Sandvoss, Torsten; Hammerschmidt, Stefan; Schellenberger, Wolfgang; Sack, Ulrich; Eschrich, Klaus; Wirtz, Hubert

    2011-01-01

    Peptide patterns of bronchoalveolar lavage fluid (BALF) were assumed to reflect the complex pathology of acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) better than clinical and inflammatory parameters and may be superior for outcome prediction. A training group of patients suffering from ALI/ARDS was compiled from equal numbers of survivors and nonsurvivors. Clinical history, ventilation parameters, Murray's lung injury severity score (Murray's LISS) and interleukins in BALF were gathered. In addition, samples of bronchoalveolar lavage fluid were analyzed by means of hydrophobic chromatography and MALDI-ToF mass spectrometry (MALDI-ToF MS). Receiver operating characteristic (ROC) analysis for each clinical and cytokine parameter revealed interleukin-6>interleukin-8>diabetes mellitus>Murray's LISS as the best outcome predictors. Outcome predicted on the basis of BALF levels of interleukin-6 resulted in 79.4% accuracy, 82.7% sensitivity and 76.1% specificity (area under the ROC curve, AUC, 0.853). Both clinical parameters and cytokines as well as peptide patterns determined by MALDI-ToF MS were analyzed by classification and regression tree (CART) analysis and support vector machine (SVM) algorithms. CART analysis including Murray's LISS, interleukin-6 and interleukin-8 in combination was correct in 78.0%. MALDI-ToF MS of BALF peptides did not reveal a single identifiable biomarker for ARDS. However, classification of patients was successfully achieved based on the entire peptide pattern analyzed using SVM. This method resulted in 90% accuracy, 93.3% sensitivity and 86.7% specificity following a 10-fold cross validation (AUC = 0.953). Subsequent validation of the optimized SVM algorithm with a test group of patients with unknown prognosis yielded 87.5% accuracy, 83.3% sensitivity and 90.0% specificity. MALDI-ToF MS peptide patterns of BALF, evaluated by appropriate mathematical methods can be of value in predicting outcome in pneumonia induced

  2. Asteroids mass determination

    International Nuclear Information System (INIS)

    Hoffmann, M.

    1989-01-01

    Basic methods for asteroid mass determinations and their errors are discussed. New results and some current developments in the astrometric method are reviewed. New methods and techniques, such as electronic imaging, radar ranging and space probes are becoming important for asteroid mass determinations. Mass and density estimations on rotational properties and possible satelites are also discussed

  3. Outcome prediction in pneumonia induced ALI/ARDS by clinical features and peptide patterns of BALF determined by mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Jochen Frenzel

    Full Text Available BACKGROUND: Peptide patterns of bronchoalveolar lavage fluid (BALF were assumed to reflect the complex pathology of acute lung injury (ALI/acute respiratory distress syndrome (ARDS better than clinical and inflammatory parameters and may be superior for outcome prediction. METHODOLOGY/PRINCIPAL FINDINGS: A training group of patients suffering from ALI/ARDS was compiled from equal numbers of survivors and nonsurvivors. Clinical history, ventilation parameters, Murray's lung injury severity score (Murray's LISS and interleukins in BALF were gathered. In addition, samples of bronchoalveolar lavage fluid were analyzed by means of hydrophobic chromatography and MALDI-ToF mass spectrometry (MALDI-ToF MS. Receiver operating characteristic (ROC analysis for each clinical and cytokine parameter revealed interleukin-6>interleukin-8>diabetes mellitus>Murray's LISS as the best outcome predictors. Outcome predicted on the basis of BALF levels of interleukin-6 resulted in 79.4% accuracy, 82.7% sensitivity and 76.1% specificity (area under the ROC curve, AUC, 0.853. Both clinical parameters and cytokines as well as peptide patterns determined by MALDI-ToF MS were analyzed by classification and regression tree (CART analysis and support vector machine (SVM algorithms. CART analysis including Murray's LISS, interleukin-6 and interleukin-8 in combination was correct in 78.0%. MALDI-ToF MS of BALF peptides did not reveal a single identifiable biomarker for ARDS. However, classification of patients was successfully achieved based on the entire peptide pattern analyzed using SVM. This method resulted in 90% accuracy, 93.3% sensitivity and 86.7% specificity following a 10-fold cross validation (AUC = 0.953. Subsequent validation of the optimized SVM algorithm with a test group of patients with unknown prognosis yielded 87.5% accuracy, 83.3% sensitivity and 90.0% specificity. CONCLUSIONS/SIGNIFICANCE: MALDI-ToF MS peptide patterns of BALF, evaluated by appropriate

  4. Ion Mass Determination

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (100) is described for determining the mass of ions, the apparatus configured to hold a plasma (101 ) having a plasma potential. The apparatus (100) comprises an electrode (102) having a surface extending in a surface plane and an insulator (104) interfacing with the electrode (102......, and a processing unit (108) configured to interpret the detected impact locations in terms of the mass of the impacting ions....

  5. Determination of selected endogenous anabolic androgenic steroids and ratios in urine by ultra high performance liquid chromatography tandem mass spectrometry and isotope pattern deconvolution.

    Science.gov (United States)

    Pitarch-Motellón, J; Sancho, J V; Ibáñez, M; Pozo, O; Roig-Navarro, A F

    2017-09-15

    An isotope dilution mass spectrometry (IDMS) method for the determination of selected endogenous anabolic androgenic steroids (EAAS) in urine by UHPLC-MS/MS has been developed using the isotope pattern deconvolution (IPD) mathematical tool. The method has been successfully validated for testosterone, epitestosterone, androsterone and etiocholanolone, employing their respective deuterated analogs using two certified reference materials (CRM). Accuracy was evaluated as recovery of the certified values and ranged from 75% to 108%. Precision was assessed in intraday (n=5) and interday (n=4) experiments, with RSDs below 5% and 10% respectively. The method was also found suitable for real urine samples, with limits of detection (LOD) and quantification (LOQ) below the normal urinary levels. The developed method meets the requirements established by the World Anti-Doping Agency for the selected steroids for Athlete Biological Passport (ABP) measurements, except in the case of androsterone, which is currently under study. Copyright © 2017. Published by Elsevier B.V.

  6. The accumulation pattern of ferruginol in the heartwood-forming Cryptomeria japonica xylem as determined by time-of-flight secondary ion mass spectrometry and quantity analysis

    Science.gov (United States)

    Kuroda, Katsushi; Fujiwara, Takeshi; Hashida, Koh; Imai, Takanori; Kushi, Masayoshi; Saito, Kaori; Fukushima, Kazuhiko

    2014-01-01

    Background and Aims Heartwood formation is a unique phenomenon of tree species. Although the accumulation of heartwood substances is a well-known feature of the process, the accumulation mechanism remains unclear. The aim of this study was to determine the accumulation process of ferruginol, a predominant heartwood substance of Cryptomeria japonica, in heartwood-forming xylem. Methods The radial accumulation pattern of ferruginol was examined from sapwood and through the intermediate wood to the heartwood by direct mapping using time-of-flight secondary ion mass spectrometry (TOF-SIMS). The data were compared with quantitative results obtained from a novel method of gas chromatography analysis using laser microdissection sampling and with water distribution obtained from cryo-scanning electron microscopy. Key Results Ferruginol initially accumulated in the middle of the intermediate wood, in the earlywood near the annual ring boundary. It accumulated throughout the entire earlywood in the inner intermediate wood, and in both the earlywood and the latewood in the heartwood. The process of ferruginol accumulation continued for more than eight annual rings. Ferruginol concentration peaked at the border between the intermediate wood and heartwood, while the concentration was less in the latewood compared wiht the earlywood in each annual ring. Ferruginol tended to accumulate around the ray parenchyma cells. In addition, at the border between the intermediate wood and heartwood, the accumulation was higher in areas without water than in areas with water. Conclusions TOF-SIMS clearly revealed ferruginol distribution at the cellular level. Ferruginol accumulation begins in the middle of intermediate wood, initially in the earlywood near the annual ring boundary, then throughout the entire earlywood, and finally across to the whole annual ring in the heartwood. The heterogeneous timing of ferruginol accumulation could be related to the distribution of ray parenchyma cells

  7. Determination of the neutron mass

    International Nuclear Information System (INIS)

    Amador V, P.; Chacon R, A.; Arcos P, A.; Rodriguez N, S.; Pinedo S, A.; Vega C, H.R.

    2005-01-01

    The binding energy of the deuteron was measured and it was determined the neutron mass starting from the nuclear reaction, 1 0 n + 1 1 H → 2 1 D + γ. The produced photon is soon a gamma ray that is emitted when the hydrogen captures a thermal neutron. The photon energy was measured using two spectrometric systems for gamma rays. A system with a detector of NaI(TI) of 3'' x 3'' and the other one with a High-purity Germanium detector. The first detector has a bigger efficiency and a smaller resolution in comparison with the second detector. The energy of the measured photon is the binding energy of the deuteron. With the measurement of the photon energy and the masses of the proton and of the deuterium it was determined the neutron mass. The value of the mass obtained with both systems it was compared with the value reported in the literature. The nuclear reaction was induced in a volume of paraffin that it was bombing with a source 239 PuBe whose activity is of 3.7 x 10 10 Bq. (Author)

  8. Higgs mass determination in supersymmetry

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Javier Pardo [Abdus Salam International Centre for Theoretical Physics, Strada Costiera 11, 34151, Trieste (Italy); SISSA International School for Advanced Studies and INFN Trieste, Via Bonomea 265, 34136, Trieste (Italy); Villadoro, Giovanni [Abdus Salam International Centre for Theoretical Physics, Strada Costiera 11, 34151, Trieste (Italy)

    2015-07-29

    We present the state-of-the-art of the effective field theory computation of the MSSM Higgs mass, improving the existing ones by including extra threshold corrections. We show that, with this approach, the theoretical uncertainty is within 1 GeV in most of the relevant parameter space. We confirm the smaller value of the Higgs mass found in the EFT computations, which implies a slightly heavier SUSY scale. We study the large tan β region, finding that sbottom thresholds might relax the upper bound on the scale of SUSY. We present SUSYHD, a fast computer code that computes the Higgs mass and its uncertainty for any SUSY scale, from the TeV to the Planck scale, even in Split SUSY, both in the (DR)-bar and in the on-shell schemes. Finally, we apply our results to derive bounds on some well motivated SUSY models, in particular we show how the value of the Higgs mass allows to determine the complete spectrum in minimal gauge mediation.

  9. Vertebrate Embryonic Cleavage Pattern Determination.

    Science.gov (United States)

    Hasley, Andrew; Chavez, Shawn; Danilchik, Michael; Wühr, Martin; Pelegri, Francisco

    2017-01-01

    The pattern of the earliest cell divisions in a vertebrate embryo lays the groundwork for later developmental events such as gastrulation, organogenesis, and overall body plan establishment. Understanding these early cleavage patterns and the mechanisms that create them is thus crucial for the study of vertebrate development. This chapter describes the early cleavage stages for species representing ray-finned fish, amphibians, birds, reptiles, mammals, and proto-vertebrate ascidians and summarizes current understanding of the mechanisms that govern these patterns. The nearly universal influence of cell shape on orientation and positioning of spindles and cleavage furrows and the mechanisms that mediate this influence are discussed. We discuss in particular models of aster and spindle centering and orientation in large embryonic blastomeres that rely on asymmetric internal pulling forces generated by the cleavage furrow for the previous cell cycle. Also explored are mechanisms that integrate cell division given the limited supply of cellular building blocks in the egg and several-fold changes of cell size during early development, as well as cytoskeletal specializations specific to early blastomeres including processes leading to blastomere cohesion. Finally, we discuss evolutionary conclusions beginning to emerge from the contemporary analysis of the phylogenetic distributions of cleavage patterns. In sum, this chapter seeks to summarize our current understanding of vertebrate early embryonic cleavage patterns and their control and evolution.

  10. τ lepton mass determination at KEDR

    International Nuclear Information System (INIS)

    Eidelman, S.I.; Anashin, V.V.; Aulchenko, V.M.; Baldin, E.M.; Barladyan, A.K.; Barnyakov, A.Yu.; Barnyakov, M.Yu.; Baru, S.E.; Basok, I.Yu.; Bedny, I.V.; Beloborodova, O.L.; Blinov, A.E.; Blinov, V.E.; Bobrov, A.V.; Bobrovnikov, V.S.; Bogomyagkov, A.V.; Bondar, A.E.; Buzykaev, A.R.; Eidelman, S.I.; Glukhovchenko, Yu.M.

    2011-01-01

    We present preliminary results of a new high-precision determination of the τ lepton mass performed with the KEDR detector at the VEPP-4M e + e - collider. These results are compared to two recent τ lepton mass measurements at Belle and BaBar.

  11. Pattern of side feeding intensity in mass 40 region

    International Nuclear Information System (INIS)

    Kshetri, Ritesh; Ray, Indrani; Mukherjee, A.

    2005-01-01

    Mass 40 region has many interesting features to offer to the fields of nuclear structure. In this paper, intention was made to study the effect of forward and inverse type of reaction and excitation energy on the side feeding intensity pattern in the mass region 40. The effect of coexistence of different types of structural features in this mass region will also be investigated

  12. Simultaneous Mass Determination for Gravitationally Coupled Asteroids

    Energy Technology Data Exchange (ETDEWEB)

    Baer, James [Private address, 3210 Apache Road, Pittsburgh, PA 15241 (United States); Chesley, Steven R., E-mail: jimbaer1@earthlink.net [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States)

    2017-08-01

    The conventional least-squares asteroid mass determination algorithm allows us to solve for the mass of a large subject asteroid that is perturbing the trajectory of a smaller test asteroid. However, this algorithm is necessarily a first approximation, ignoring the possibility that the subject asteroid may itself be perturbed by the test asteroid, or that the encounter’s precise geometry may be entangled with encounters involving other asteroids. After reviewing the conventional algorithm, we use it to calculate the masses of 30 main-belt asteroids. Compared to our previous results, we find new mass estimates for eight asteroids (11 Parthenope, 27 Euterpe, 51 Neimausa, 76 Freia, 121 Hermione, 324 Bamberga, 476 Hedwig, and 532 Herculina) and significantly more precise estimates for six others (2 Pallas, 3 Juno, 4 Vesta, 9 Metis, 16 Psyche, and 88 Thisbe). However, we also find that the conventional algorithm yields questionable results in several gravitationally coupled cases. To address such cases, we describe a new algorithm that allows the epoch state vectors of the subject asteroids to be included as solve-for parameters, allowing for the simultaneous solution of the masses and epoch state vectors of multiple subject and test asteroids. We then apply this algorithm to the same 30 main-belt asteroids and conclude that mass determinations resulting from current and future high-precision astrometric sources (such as Gaia ) should conduct a thorough search for possible gravitational couplings and account for their effects.

  13. Simultaneous Mass Determination for Gravitationally Coupled Asteroids

    Science.gov (United States)

    Baer, James; Chesley, Steven R.

    2017-08-01

    The conventional least-squares asteroid mass determination algorithm allows us to solve for the mass of a large subject asteroid that is perturbing the trajectory of a smaller test asteroid. However, this algorithm is necessarily a first approximation, ignoring the possibility that the subject asteroid may itself be perturbed by the test asteroid, or that the encounter’s precise geometry may be entangled with encounters involving other asteroids. After reviewing the conventional algorithm, we use it to calculate the masses of 30 main-belt asteroids. Compared to our previous results, we find new mass estimates for eight asteroids (11 Parthenope, 27 Euterpe, 51 Neimausa, 76 Freia, 121 Hermione, 324 Bamberga, 476 Hedwig, and 532 Herculina) and significantly more precise estimates for six others (2 Pallas, 3 Juno, 4 Vesta, 9 Metis, 16 Psyche, and 88 Thisbe). However, we also find that the conventional algorithm yields questionable results in several gravitationally coupled cases. To address such cases, we describe a new algorithm that allows the epoch state vectors of the subject asteroids to be included as solve-for parameters, allowing for the simultaneous solution of the masses and epoch state vectors of multiple subject and test asteroids. We then apply this algorithm to the same 30 main-belt asteroids and conclude that mass determinations resulting from current and future high-precision astrometric sources (such as Gaia) should conduct a thorough search for possible gravitational couplings and account for their effects.

  14. Simultaneous Mass Determination for Gravitationally Coupled Asteroids

    International Nuclear Information System (INIS)

    Baer, James; Chesley, Steven R.

    2017-01-01

    The conventional least-squares asteroid mass determination algorithm allows us to solve for the mass of a large subject asteroid that is perturbing the trajectory of a smaller test asteroid. However, this algorithm is necessarily a first approximation, ignoring the possibility that the subject asteroid may itself be perturbed by the test asteroid, or that the encounter’s precise geometry may be entangled with encounters involving other asteroids. After reviewing the conventional algorithm, we use it to calculate the masses of 30 main-belt asteroids. Compared to our previous results, we find new mass estimates for eight asteroids (11 Parthenope, 27 Euterpe, 51 Neimausa, 76 Freia, 121 Hermione, 324 Bamberga, 476 Hedwig, and 532 Herculina) and significantly more precise estimates for six others (2 Pallas, 3 Juno, 4 Vesta, 9 Metis, 16 Psyche, and 88 Thisbe). However, we also find that the conventional algorithm yields questionable results in several gravitationally coupled cases. To address such cases, we describe a new algorithm that allows the epoch state vectors of the subject asteroids to be included as solve-for parameters, allowing for the simultaneous solution of the masses and epoch state vectors of multiple subject and test asteroids. We then apply this algorithm to the same 30 main-belt asteroids and conclude that mass determinations resulting from current and future high-precision astrometric sources (such as Gaia ) should conduct a thorough search for possible gravitational couplings and account for their effects.

  15. Mass transport in propagating patterns of convection

    International Nuclear Information System (INIS)

    Moses, E.; Steinberg, V.

    1988-01-01

    Recent studies of propagating waves in an oscillatory convection of binary mixtures arise questions about transport properties of this flow. Optical visualization of a field of refraction index due to a shadowgraph technique gives information on the temperature and concentration fields. However, experimental observation of rolls propagating along the cell as travelling waves (TW) does not necessarily imply that mass is transferred hydrodynamically by the convective motion along the cell. One of the possibilities discussed, e.g., is that TW observed is only a phase propagation. The traditional examples of such situations come from the domain of linear, superposition-oriented physics. Acoustic waves transfer momentum and energy, but do not cause the mass to make excursions for their equilibrium point that are larger than the oscillation amplitude. In the case of nonlinear physics we were aware that small amplitude surface waves cause only small oscillatory motion round the equilibrium point, while larger amplitudes can cause the mass to start moving in the direction of the TW. This paper discussed the different possibilities of mass transfer by TW. 27 refs., 20 figs

  16. A new determination of the pion mass

    International Nuclear Information System (INIS)

    Anagnastopoulos, D.; Belmiloud, D.; El-Khoury, P.; Indelicato, P.; Borchert, G.; Gorke, H.; Gotta, D.; Lenz, S.; Siems, T.; Daum, M.; Frosch, R.; Hauser, P.; Kirch, K.; Simons, L.M.

    1996-01-01

    Initial measurements concerning the feasibility of a new pion mass determination are described. In a first step, a high-resolution crystal spectrometer was coupled to a cyclotron trap which provides a high pion stopping density, sufficient to check predictions for the cascade process and to measure the stability of the apparatus. A comparison with the measured Cu K α fluorescence line resolves an ambiguity in the value of the pion mass. The preliminary result from this experiment is m π -=(139.57040±0.00045) MeV/c 2 . (orig.)

  17. Pattern of Conjunctival Masses Seen At Guinness Eye Centre Luth ...

    African Journals Online (AJOL)

    Pattern of Conjunctival Masses Seen At Guinness Eye Centre Luth Idi-Araba. ... Open Access DOWNLOAD FULL TEXT Subscription or Fee ... 13.2% of eyes. Our study however did not confirm outdoor occupations as a risk factor for pterygium.

  18. Neutrino mass matrices with vanishing determinant

    International Nuclear Information System (INIS)

    Chauhan, Bhag C.; Pulido, Joao; Picariello, Marco

    2006-01-01

    We investigate the prospects for neutrinoless double beta decay, texture zeros. and equalities between neutrino mass matrix elements in scenarios with vanishing determinant mass matrices for vanishing and finite θ 13 mixing angles in normal and inverse mass hierarchies. For normal hierarchy and both zero and finite θ 13 it is found that neutrinoless double beta decay cannot be observed by any of the present or next generation experiments, while for inverse hierarchy it is, on the contrary, accessible to experiments. Regarding texture zeros and equalities between mass matrix elements, we find that in both normal and inverse hierarchies with θ 13 =0 no texture zeros nor any such equalities can exist apart from the obvious ones. For θ 13 ≠0 some texture zeros become possible. In normal hierarchy two texture zeros occur if 8.1x10 -2 ≤sinθ 13 ≤9.1x10 -2 while in inverse hierarchy three are possible, one with sinθ 13 ≥7x10 -3 and two others with sinθ 13 ≥0.18. All equalities between mass matrix elements are impossible with θ 13 ≠0

  19. Contemporary labor patterns: the impact of maternal body mass index.

    Science.gov (United States)

    Kominiarek, Michelle A; Zhang, Jun; Vanveldhuisen, Paul; Troendle, James; Beaver, Julie; Hibbard, Judith U

    2011-09-01

    We sought to compare labor patterns by body mass index (BMI). A total of 118,978 gravidas with a singleton term cephalic gestation were studied. Repeated-measures analysis constructed mean labor curves by parity and BMI categories for those who reached 10 cm. Interval-censored regression analysis determined median traverse times, adjusting for covariates in vaginal deliveries and intrapartum cesareans. In the labor curves, the time difference to reach 10 cm was 1.2 hours from the lowest to highest BMI category for nulliparas. Multiparas entered active phase by 6 cm, but reaching this point took longer for BMI ≥40.0 (3.4 hours) compared to BMI .05) but decreased as BMI increased for multiparas (P < .001). Labor proceeds more slowly as BMI increases, suggesting that labor management be altered to allow longer time for these differences. Copyright © 2011 Mosby, Inc. All rights reserved.

  20. Dietary Patterns and Body Mass Index in Children with Autism and Typically Developing Children

    Science.gov (United States)

    Evans, E. Whitney; Must, Aviva; Anderson, Sarah E.; Curtin, Carol; Scampini, Renee; Maslin, Melissa; Bandini, Linda

    2012-01-01

    To determine whether dietary patterns (juice and sweetened non-dairy beverages, fruits, vegetables, fruits and vegetables, snack foods, and kid's meals) and associations between dietary patterns and body mass index (BMI) differed between 53 children with autism spectrum disorders (ASD) and 58 typically developing children, ages 3-11, multivariate…

  1. Changes in Kicking Pattern: Effect of Experience, Speed, Accuracy, and Effective Striking Mass

    Science.gov (United States)

    Southard, Dan L.

    2014-01-01

    Purpose: The purposes of this study were to: (a) examine the effect of experience and goal constraints (speed, accuracy) on kicking patterns; (b) determine if effective striking mass was independent of ankle velocity at impact; and (c) determine the accuracy of kicks relative to independent factors. Method: Twenty participants were recruited to…

  2. Mass Determination of Entire Amyloid Fibrils by Using Mass Spectrometry.

    Science.gov (United States)

    Doussineau, Tristan; Mathevon, Carole; Altamura, Lucie; Vendrely, Charlotte; Dugourd, Philippe; Forge, Vincent; Antoine, Rodolphe

    2016-02-12

    Amyloid fibrils are self-assembled protein structures with important roles in biology (either pathogenic or physiological), and are attracting increasing interest in nanotechnology. However, because of their high aspect ratio and the presence of some polymorphism, that is, the possibility to adopt various structures, their characterization is challenging and basic information such as their mass is unknown. Here we show that charge-detection mass spectrometry, recently developed for large self-assembled systems such as viruses, provides such information in a straightforward manner. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Pattern changes in determinants of Chinese emissions

    Science.gov (United States)

    Mi, Zhifu; Meng, Jing; Guan, Dabo; Shan, Yuli; Liu, Zhu; Wang, Yutao; Feng, Kuishuang; Wei, Yi-Ming

    2017-07-01

    The Chinese economy has been recovering slowly from the global financial crisis, but it cannot achieve the same rapid development of the pre-recession period. Instead, the country has entered a new phase of economic development—a ‘new normal’. We use a structural decomposition analysis and environmental input-output analysis to estimate the determinants of China’s carbon emission changes during 2005-2012. China’s imports are linked to a global multi-regional input-output model based on the Global Trade and Analysis Project database to calculate the embodied CO2 emissions in imports. We find that the global financial crisis has affected the drivers of China’s carbon emission growth. From 2007 to 2010, the CO2 emissions induced by China’s exports dropped, whereas emissions induced by capital formation grew rapidly. In the ‘new normal’, the strongest factors that offset CO2 emissions have shifted from efficiency gains to structural upgrading. Efficiency was the strongest factor offsetting China’s CO2 emissions before 2010 but drove a 1.4% increase in emissions in the period 2010-2012. By contrast, production structure and consumption patterns caused a 2.6% and 1.3% decrease, respectively, in China’s carbon emissions from 2010 to 2012. In addition, China tends to shift gradually from an investment to a consumption-driven economy. The proportion of CO2 emissions induced by consumption had a declining trend before 2010 but grew from 28.6%-29.1% during 2010-2012.

  4. Burnup determination of mass spectrometry for nuclear fuels

    International Nuclear Information System (INIS)

    Zhang Chunhua.

    1987-01-01

    The various methods currently being used in burnup determination of nuclear fuels are studied and reviewed. The mass spectrometry method of destructive testing is discussed emphatically. The burnup determination of mass spectrometry includes heavy isotopic abundance ratio method and isotope dilution mass spectrometry used as burnup indicator for the fission products. The former is applied to high burnup level, but the later to various burnup level. According to experiences, some problems which should be noticed in burnup determination of mass spectrometry are presented

  5. Mass determination of Hercules X-1

    International Nuclear Information System (INIS)

    Bahcall, J.N.; Chester, T.J.

    1977-01-01

    The allowed range of masses for Hercules X-1 is calculated using the optical pulsation data of Middleditch and Nelson, a simple geometrical model for the optical pulsations, and Uhuru X-ray observations of the mass function and eclipse duration. For a specific set of assumptions, we obtain 0.6M/sub sun/ 1 < or =2.0M/sub sun/

  6. Determining the neutrino mass hierarchy with cosmology

    International Nuclear Information System (INIS)

    De Bernardis, Francesco; Kitching, Thomas D.; Heavens, Alan; Melchiorri, Alessandro

    2009-01-01

    The combination of current large-scale structure and cosmic microwave background anisotropies data can place strong constraints on the sum of the neutrino masses. Here we show that future cosmic shear experiments, in combination with cosmic microwave background constraints, can provide the statistical accuracy required to answer questions about differences in the mass of individual neutrino species. Allowing for the possibility that masses are nondegenerate we combine Fisher matrix forecasts for a weak lensing survey like Euclid with those for the forthcoming Planck experiment. Under the assumption that neutrino mass splitting is described by a normal hierarchy we find that the combination Planck and Euclid will possibly reach enough sensitivity to put a constraint on the mass of a single species. Using a Bayesian evidence calculation we find that such future experiments could provide strong evidence for either a normal or an inverted neutrino hierarchy. Finally we show that if a particular neutrino hierarchy is assumed then this could bias cosmological parameter constraints, for example, the dark energy equation of state parameter, by > or approx. 1σ, and the sum of masses by 2.3σ. We finally discuss the impact of uncertainties on the theoretical modeling of nonlinearities. The results presented in this analysis are obtained under an approximation to the nonlinear power spectrum. This significant source of uncertainty needs to be addressed in future work.

  7. Position and mass determination of multiple particles using cantilever based mass sensors

    International Nuclear Information System (INIS)

    Dohn, Soeren; Schmid, Silvan; Boisen, Anja; Amiot, Fabien

    2010-01-01

    Resonant microcantilevers are highly sensitive to added masses and have the potential to be used as mass-spectrometers. However, making the detection of individual added masses quantitative requires the position determination for each added mass. We derive expressions relating the position and mass of several added particles to the resonant frequencies of a cantilever, and an identification procedure valid for particles with different masses is proposed. The identification procedure is tested by calculating positions and mass of multiple microparticles with similar mass positioned on individual microcantilevers. Excellent agreement is observed between calculated and measured positions and calculated and theoretical masses.

  8. Precision Determination of the Top Quark Mass

    Energy Technology Data Exchange (ETDEWEB)

    Movilla Fernandez, Pedro A.; /LBL, Berkeley

    2007-05-01

    The CDF and D0 collaborations have updated their measurements of the mass of the top quark using proton-antiproton collisions at {radical}s = 1.96 TeV produced at the Tevatron. The uncertainties in each of the top-antitop decay channels have been reduced. The new Tevatron average for the mass of the top quark based on about 1 fb{sup -1} of data per experiment is 170.9 {+-} 1.8 GeV/c{sup 2}.

  9. Socioeconomic determinants of eating pattern of adolescent ...

    African Journals Online (AJOL)

    Introduction During the last few decades, Egypt experienced rapid socio-cultural changes that were associated with major changes in the food choices and eating habits, which, progressively, becomes more westernized. The objective of this study was to investigate the meal patterns of secondary school adolescent ...

  10. Mass and position determination in MEMS mass sensors: a theoretical and an experimental investigation

    KAUST Repository

    Bouchaala, Adam M.; Nayfeh, Ali H.; Jaber, Nizar; Younis, Mohammad I.

    2016-01-01

    We present a method to determine accurately the position and mass of an entity attached to the surface of an electrostatically actuated clamped-clamped microbeam implemented as a mass sensor. In the theoretical investigation, the microbeam

  11. Top quark kinematics and mass determination

    International Nuclear Information System (INIS)

    Williams, H.H.

    1994-10-01

    An analysis is presented of 10 W + ≥ 3 jet events, each with evidence for the presence of a b quark, that were recently observed by the CDF collaboration. Seven of these events include a fourth jet and can be explicitly reconstructed as t bar t production. The best estimate of the top quark mass is M t = 174 ± 10 -12 +13 GeV/c 2 . A study has also been performed to see if the kinematical properties of events with W + ≥ 3 jets gives evidence for top production. An excess of events with large jet energies, compared to that expected from direct production of W + ≥ 3 jets, is observed. A large fraction of these events also contain a b-quark and a fourth jet

  12. Precision determination of the top-quark mass

    International Nuclear Information System (INIS)

    Moch, Sven-Olaf

    2014-08-01

    Precision determinations of the top-quark mass require theory predictions with a well-defined mass parameter in a given renormalization scheme. The top-quark's running mass in the MS scheme can be extracted with good precision from the total cross section at next-to-next-to-leading order in QCD. The Monte Carlo top-quark mass parameter measured from comparison to events with top-quark decay products is not identical with the pole mass. Its translation to the pole mass scheme introduces an additional uncertainty of the order of 1 GeV.

  13. Associations of Bone Mineral Density with Lean Mass, Fat Mass, and Dietary Patterns in Postmenopausal Chinese Women: A 2-Year Prospective Study.

    Directory of Open Access Journals (Sweden)

    Yongjie Chen

    Full Text Available To assess factors associated with bone mineral density (BMD in postmenopausal women in a longitudinal study, and to examine the relative contribution of lean mass, fat mass, dietary patterns, and years since menopause to BMD.Two hundred and eighty-two postmenopausal women were randomly selected from Hongqi Community Health Center, in Harbin City, China. All participants were followed up from 2009 to 2011. Dietary data were collected using a Food Frequency Questionnaire. BMD of the left hip, the lumbar spine, and the total body, and the body composition were measured by dual-energy X-ray absorptiometry at baseline and follow-up.Lean mass and fat mass were positively associated with BMD of the spine, hip, and the total body at both baseline and follow-up. The association between fat mass and BMD at the spine at baseline (P = 0.210 and at the spine (P = 0.116 and hip (P = 0.073 in the second year was not statistically significant when height was adjusted. Six dietary patterns were identified but only cereal grains-fruits pattern (P = 0.001 in the spine, P = 0.037 in hip and milk-root vegetables pattern (P = 0.010 in hip were associated with BMD of the spine and hip. The linear mixed model of follow-up data showed that lean mass, years since menopause, and age of menophania were the significant determinants of BMD of all sites. Moreover, lean mass was the best determinant of BMD (VIP = 1.936.Lean mass, years since menopause, age of menophania and dietary patterns are the important determinants of BMD of the spine, hip, and the total body. Lean mass is the best determinant of BMD.

  14. A Method To Determine Adhesion Of Suppository Mass On Excised ...

    African Journals Online (AJOL)

    A method to determine adhesion of suppository mass to intestinal tissue was developed using excised pig intestine. The method which employs the principe of drainage unto and subsequent detachment from the mucosa, of an adherent suppository mass is simple, inexpensive and accurate. Fully optimised, it can be used ...

  15. Jellyfish movement data - Determining Movement Patterns of Jellyfish

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project is to determine horizontal and vertical movement patterns of two jellyfish species in Hood Canal, in relation to environmental variables. It is being...

  16. Cultural, socioeconomic and nutritional determinants of functional food consumption patterns.

    Science.gov (United States)

    Mullie, P; Guelinckx, I; Clarys, P; Degrave, E; Hulens, M; Vansant, G

    2009-11-01

    The aim of our research was to describe cultural, socioeconomic and nutritional determinants associated with functional food consumption. Cross-sectional design in 5000 military men. Using mailed questionnaires, the functional food consumption frequency was recorded. Margarines fortified with phytosterols or phytostanols were used on a daily basis by 26.3% of the responders. Only 4.7% took a daily portion of probiotics, whereas 14.0% consumed one or more portions of nuts a week. One man out of three consumed one cup of tea daily, whereas 10.2% consumed one glass of red wine daily. Three or more portions of fruit a day were consumed by 19.1%, and two or more portions of vegetables a day by 26.6%. Only 12.3% consumed a portion of fatty fish weekly. After adjustment for age, body mass index, physical activity, use of vitamin supplements, smoking, marital status, cultural background, educational and income level, the daily consumption of fortified margarines increased with age. The consumption of fermented dairy products increased with physical activity and with the use of vitamin supplements. The consumption of fortified margarines, nuts, tea and fatty fish was strongly influenced by cultural background, with higher consumptions for Flemish-speaking men compared with French-speaking persons. Daily consumption of red wine was higher in French-speaking men and in higher educated men. Finally, functional food consumption was associated with a healthy dietary pattern. Age, physical activity, level of education, use of vitamin supplements and cultural background are predictors of functional food consumption patterns.

  17. Effects of body mass index on sleep patterns during pregnancy.

    LENUS (Irish Health Repository)

    Kennelly, M M

    2011-01-01

    The purpose of this study was to profile sleep patterns during pregnancy according to body mass index (BMI) and to correlate labour outcomes with both BMI and hours sleep. Data were collected from 200 postpartum women detailing sleep characteristics before and during pregnancy. A validated sleep questionnaire was employed, which comprised of questions about sleep apnoea, snoring, subjective sleep quality, sleep latency, sleep duration, habitual sleep efficiency, sleep disturbances, use of sleeping medication and daytime dysfunction. Descriptive analyses were used. With advancing gestation, the mean (SD) number of hours sleep per night declined: pre-pregnancy 8.1 (SD 1.4); 1st trimester 8.3 (SD 1.8); 2nd trimester 7.7 (SD 1.7) and 3rd trimester 6.7 (SD 2.2). In the 18.5-24.9 BMI group, there was a marked difference in hours sleep per night from pre-pregnancy to 1st (8.6 h, p = 0.007), 2nd (7.9 h, p = 0.023) and 3rd (6.4 h, p = 0.000) trimesters in primiparous women. In the 25-29.9 BMI group, there was a difference from pre-pregnancy to 3rd trimester (p = 0.000). These changes were not reflected in a clinically significant difference in birth weight or mode of delivery.

  18. Body Mass Index and Menstrual Patterns in Dancers.

    Science.gov (United States)

    Stracciolini, Andrea; Quinn, Bridget J; Geminiani, Ellen; Kinney, Susan; McCrystal, Tara; Owen, Michael; Pepin, Michael J; Stein, Cynthia J

    2016-04-18

    Questionnaires were distributed to investigate body mass index (BMI) and menstrual patterns in female dancers aged 12 to 17 years. The study cohort consisted of 105 dancers, mean age 14.8 ± 1.1 years, and mean BMI 19.5 ± 2.3 kg/m 2 In all, 92% were healthy weight for height. First menses age ranged from 10 to 15 years (mean 12.9 ± 1.1 years). A total of 44% reported irregular menses; of those, 14% described irregularity as "every other month," 37% as "every 3 months," and 49% as "skips a month occasionally." A total of 36% of the dancers stop getting their menses during times of increased activity/dance, and 30% have gone >3 months at any time without getting their menses. A significant negative correlation between BMI and age of first menses was found with lower BMI associated with increased age of first menses (linear regression, β = -0.49,P= .021). This study supports an association between BMI and age of menarche among young female dancers. Given bone health reliance on hormonal milieu in female dancers, future research is warranted. © The Author(s) 2016.

  19. Structural determination of intact proteins using mass spectrometry

    Science.gov (United States)

    Kruppa, Gary [San Francisco, CA; Schoeniger, Joseph S [Oakland, CA; Young, Malin M [Livermore, CA

    2008-05-06

    The present invention relates to novel methods of determining the sequence and structure of proteins. Specifically, the present invention allows for the analysis of intact proteins within a mass spectrometer. Therefore, preparatory separations need not be performed prior to introducing a protein sample into the mass spectrometer. Also disclosed herein are new instrumental developments for enhancing the signal from the desired modified proteins, methods for producing controlled protein fragments in the mass spectrometer, eliminating complex microseparations, and protein preparatory chemical steps necessary for cross-linking based protein structure determination.Additionally, the preferred method of the present invention involves the determination of protein structures utilizing a top-down analysis of protein structures to search for covalent modifications. In the preferred method, intact proteins are ionized and fragmented within the mass spectrometer.

  20. Associations between lifestyle patterns and body mass index in a sample of Greek children and adolescents

    NARCIS (Netherlands)

    Kontogianni, Meropi D; Farmaki, Anastasia-Eleni; Vidra, Nikoletta; Sofrona, Stavroula; Magkanari, Flora; Yannakoulia, Mary

    BACKGROUND: Although eating and physical activity behaviors have been previously individually investigated with regard to overweight in children, multidimensional lifestyle patterns, based on these behaviors, have not been explored. OBJECTIVE: To assess lifestyle patterns in relation to body mass

  1. Patterns to Enable Mass-Customized Business Process Monitoring

    NARCIS (Netherlands)

    Jochem Vonk; dr Marco Comuzzi; dr. Samuil Angelov

    2012-01-01

    Mass-customization challenges the one-size-fits-all assumption of mass production, allowing customers to specify the options that best fit their requirements when choosing a product or a service. In business process management, to achieve mass-customization, providers offer to their customers the

  2. Patterns to enable mass-customized business process monitoring

    NARCIS (Netherlands)

    Comuzzi, M.; Angelov, S.A.; Vonk, J.; Ralyté, J,; Franch, X.; Brinkkemper, S.; Wrycza, S.

    2012-01-01

    Mass-customization challenges the one-size-fits-all assumption of mass production, allowing customers to specify the options that best fit their requirements when choosing a product or a service. In business process management, to achieve mass-customization, providers offer to their customers the

  3. The double mass hierarchy pattern: Simultaneously understanding quark and lepton mixing

    Science.gov (United States)

    Hollik, Wolfgang Gregor; Saldaña Salazar, Ulises Jesús

    2015-03-01

    The charged fermion masses of the three generations exhibit the two strong hierarchies m3 ≫m2 ≫m1. We assume that also neutrino masses satisfy mν3 >mν2 >mν1 and derive the consequences of the hierarchical spectra on the fermionic mixing patterns. The quark and lepton mixing matrices are built in a general framework with their matrix elements expressed in terms of the four fermion mass ratios, mu /mc, mc /mt, md /ms and ms /mb, and me /mμ, mμ /mτ, mν1 /mν2 and mν2 /mν3, for the quark and lepton sector, respectively. In this framework, we show that the resulting mixing matrices are consistent with data for both quarks and leptons, despite the large leptonic mixing angles. The minimal assumption we take is the one of hierarchical masses and minimal flavor symmetry breaking that strongly follows from phenomenology. No special structure of the mass matrices has to be assumed that cannot be motivated by this minimal assumption. This analysis allows us to predict the neutrino mass spectrum and set the mass of the lightest neutrino well below 0.01 eV. The method also gives the 1σ allowed ranges for the leptonic mixing matrix elements. Contrary to the common expectation, leptonic mixing angles are found to be determined solely by the four leptonic mass ratios without any relation to symmetry considerations as commonly used in flavor model building. Still, our formulae can be used to build up a flavor model that predicts the observed hierarchies in the masses - the mixing follows then from the procedure which is developed in this work.

  4. Maternal dietary patterns during pregnancy and childhood bone mass: a longitudinal study.

    Science.gov (United States)

    Cole, Zoe A; Gale, Catharine R; Javaid, M Kassim; Robinson, Sian M; Law, Catherine; Boucher, Barbara J; Crozier, Sarah R; Godfrey, Keith M; Dennison, Elaine M; Cooper, Cyrus

    2009-04-01

    Maternal nutrition is a potentially important determinant of intrauterine skeletal development. Previous studies have examined the effects of individual nutrients, but the pattern of food consumption may be of greater relevance. We therefore examined the relationship between maternal dietary pattern during pregnancy and bone mass of the offspring at 9 yr of age. We studied 198 pregnant women 17-43 yr of age and their offspring at 9 yr of age. Dietary pattern was assessed using principal component analysis from a validated food frequency questionnaire. The offspring underwent measurements of bone mass using DXA at 9 yr of age. A high prudent diet score was characterized by elevated intakes of fruit, vegetables, and wholemeal bread, rice, and pasta and low intakes of processed foods. Higher prudent diet score in late pregnancy was associated with greater (p socioeconomic status, height, arm circumference, maternal smoking, and vitamin D status. Associations with prudent diet score in early pregnancy were weaker and nonsignificant. We conclude that dietary patterns consistent with current advice for healthy eating during pregnancy are associated with greater bone size and BMD in the offspring at 9 yr of age.

  5. Qualitative pattern classification of shear wave elastography for breast masses: how it correlates to quantitative measurements.

    Science.gov (United States)

    Yoon, Jung Hyun; Ko, Kyung Hee; Jung, Hae Kyoung; Lee, Jong Tae

    2013-12-01

    To determine the correlation of qualitative shear wave elastography (SWE) pattern classification to quantitative SWE measurements and whether it is representative of quantitative SWE values with similar performances. From October 2012 to January 2013, 267 breast masses of 236 women (mean age: 45.12 ± 10.54 years, range: 21-88 years) who had undergone ultrasonography (US), SWE, and subsequent biopsy were included. US BI-RADS final assessment and qualitative and quantitative SWE measurements were recorded. Correlation between pattern classification and mean elasticity, maximum elasticity, elasticity ratio and standard deviation were evaluated. Diagnostic performances of grayscale US, SWE parameters, and US combined to SWE values were calculated and compared. Of the 267 breast masses, 208 (77.9%) were benign and 59 (22.1%) were malignant. Pattern classifications significantly correlated with all quantitative SWE measurements, showing highest correlation with maximum elasticity, r = 0.721 (P0.05). Pattern classification shows high correlation to maximum stiffness and may be representative of quantitative SWE values. When combined to grayscale US, SWE improves specificity of US. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Qualitative pattern classification of shear wave elastography for breast masses: How it correlates to quantitative measurements

    International Nuclear Information System (INIS)

    Yoon, Jung Hyun; Ko, Kyung Hee; Jung, Hae Kyoung; Lee, Jong Tae

    2013-01-01

    Objective: To determine the correlation of qualitative shear wave elastography (SWE) pattern classification to quantitative SWE measurements and whether it is representative of quantitative SWE values with similar performances. Methods: From October 2012 to January 2013, 267 breast masses of 236 women (mean age: 45.12 ± 10.54 years, range: 21–88 years) who had undergone ultrasonography (US), SWE, and subsequent biopsy were included. US BI-RADS final assessment and qualitative and quantitative SWE measurements were recorded. Correlation between pattern classification and mean elasticity, maximum elasticity, elasticity ratio and standard deviation were evaluated. Diagnostic performances of grayscale US, SWE parameters, and US combined to SWE values were calculated and compared. Results: Of the 267 breast masses, 208 (77.9%) were benign and 59 (22.1%) were malignant. Pattern classifications significantly correlated with all quantitative SWE measurements, showing highest correlation with maximum elasticity, r = 0.721 (P < 0.001). Sensitivity was significantly decreased in US combined to SWE measurements to grayscale US: 69.5–89.8% to 100.0%, while specificity was significantly improved: 62.5–81.7% to 13.9% (P < 0.001). Area under the ROC curve (A z ) did not show significant differences between grayscale US to US combined to SWE (P > 0.05). Conclusion: Pattern classification shows high correlation to maximum stiffness and may be representative of quantitative SWE values. When combined to grayscale US, SWE improves specificity of US

  7. Qualitative pattern classification of shear wave elastography for breast masses: How it correlates to quantitative measurements

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung Hyun, E-mail: lvjenny0417@gmail.com [Department of Radiology, CHA Bundang Medical Center, CHA University, School of Medicine (Korea, Republic of); Department of Radiology, Research Institute of Radiological Science, Yonsei University, College of Medicine (Korea, Republic of); Ko, Kyung Hee, E-mail: yourheeya@cha.ac.kr [Department of Radiology, CHA Bundang Medical Center, CHA University, School of Medicine (Korea, Republic of); Jung, Hae Kyoung, E-mail: AA40501@cha.ac.kr [Department of Radiology, CHA Bundang Medical Center, CHA University, School of Medicine (Korea, Republic of); Lee, Jong Tae, E-mail: jtlee@cha.ac.kr [Department of Radiology, CHA Bundang Medical Center, CHA University, School of Medicine (Korea, Republic of)

    2013-12-01

    Objective: To determine the correlation of qualitative shear wave elastography (SWE) pattern classification to quantitative SWE measurements and whether it is representative of quantitative SWE values with similar performances. Methods: From October 2012 to January 2013, 267 breast masses of 236 women (mean age: 45.12 ± 10.54 years, range: 21–88 years) who had undergone ultrasonography (US), SWE, and subsequent biopsy were included. US BI-RADS final assessment and qualitative and quantitative SWE measurements were recorded. Correlation between pattern classification and mean elasticity, maximum elasticity, elasticity ratio and standard deviation were evaluated. Diagnostic performances of grayscale US, SWE parameters, and US combined to SWE values were calculated and compared. Results: Of the 267 breast masses, 208 (77.9%) were benign and 59 (22.1%) were malignant. Pattern classifications significantly correlated with all quantitative SWE measurements, showing highest correlation with maximum elasticity, r = 0.721 (P < 0.001). Sensitivity was significantly decreased in US combined to SWE measurements to grayscale US: 69.5–89.8% to 100.0%, while specificity was significantly improved: 62.5–81.7% to 13.9% (P < 0.001). Area under the ROC curve (A{sub z}) did not show significant differences between grayscale US to US combined to SWE (P > 0.05). Conclusion: Pattern classification shows high correlation to maximum stiffness and may be representative of quantitative SWE values. When combined to grayscale US, SWE improves specificity of US.

  8. Determination of absolute neutrino masses from Z-bursts

    International Nuclear Information System (INIS)

    Fodor, Z.

    2001-05-01

    Ultrahigh energy neutrinos (UHEν) scatter on cosmological relic neutrinos (Rν) producing Z bosons, which can decay hadronically producing protons (Z-burst). We compare the predicted proton spectrum with the observed ultrahigh energy cosmic ray (UHECR) spectrum and determine the mass of the heaviest Rν via a maximum likelihood analysis. Our mass prediction depends on the origin of the power-like part of the UHECR spectrum: m ν = 2.34 -0.84 +1.29 eV for Galactic halo and 0.26 -0.14 +0.20 eV for extragalactic (EG) origin. The second mass, with a lower bound of 0.06 eV on the 95% confidence level (CL), is compatible with a hierarchical ν mass scenario with the largest mass suggested by the atmospheric ν oscillation. The necessary UHEν flux is compatible with present upper limits and should be detected in the near future. (orig.)

  9. Workshop on Top mass: challenges in definition and determination

    CERN Document Server

    2015-01-01

    The top-quark mass definition and determination is a major subject of debate in both theoretical and experimental communities. Different strategies to relate the measured and theoretical quantities have been envisaged. The aim of this 3-day meeting is to convene experts on this topic to stimulate an informal discussion on different aspects of the issue. We plan to have only three or four talks each day, and plenty of time to discuss the connection between the experimentally reconstructed top mass relying on Monte Carlo generators and different theoretical mass definitions, including the most advanced strategies. Implications of the top-mass determination for physics beyond the standard model will be also covered. The general approach and format will be pedagogical, the audience ranging from top-quark physics experts to graduate students, and should favour extended discussion among participants.

  10. High-accuracy mass determination of unstable nuclei with a Penning trap mass spectrometer

    CERN Multimedia

    2002-01-01

    The mass of a nucleus is its most fundamental property. A systematic study of nuclear masses as a function of neutron and proton number allows the observation of collective and single-particle effects in nuclear structure. Accurate mass data are the most basic test of nuclear models and are essential for their improvement. This is especially important for the astrophysical study of nuclear synthesis. In order to achieve the required high accuracy, the mass of ions captured in a Penning trap is determined via their cyclotron frequency $ \

  11. Determining the dark matter mass with DeepCore

    Energy Technology Data Exchange (ETDEWEB)

    Das, Chitta R. [Centro de Física Teórica de Partículas, Instituto Superior Técnico (CFTP), Universidade Tćnica de Lisboa, Avenida Rovisco Pais 1, 1049-001 Lisboa (Portugal); Mena, Olga [Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Palomares-Ruiz, Sergio, E-mail: sergio.palomares.ruiz@ist.utl.pt [Centro de Física Teórica de Partículas, Instituto Superior Técnico (CFTP), Universidade Tćnica de Lisboa, Avenida Rovisco Pais 1, 1049-001 Lisboa (Portugal); Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Pascoli, Silvia [IPPP, Department of Physics, Durham University, Durham DH1 3LE (United Kingdom)

    2013-10-01

    Cosmological and astrophysical observations provide increasing evidence of the existence of dark matter in our Universe. Dark matter particles with a mass above a few GeV can be captured by the Sun, accumulate in the core, annihilate, and produce high energy neutrinos either directly or by subsequent decays of Standard Model particles. We investigate the prospects for indirect dark matter detection in the IceCube/DeepCore neutrino telescope and its capabilities to determine the dark matter mass.

  12. Volumetric determination of tumor size abdominal masses. Problems -feasabilities

    International Nuclear Information System (INIS)

    Helmberger, H.; Bautz, W.; Sendler, A.; Fink, U.; Gerhardt, P.

    1995-01-01

    The most important indication for clinically reliable volumetric determination of tumor size in the abdominal region is monitoring liver metastases during chemotherapy. Determination of volume can be effectively realized using 3D reconstruction. Therefore, the primary data set must be complete and contiguous. The mass should be depicted strongly enhanced and free of artifacts. At present, this prerequisite can only be complied with using thin-slice spiral CT. Phantom studies have proven that a semiautomatic reconstruction algorithm is recommendable. The basic difficulties involved in volumetric determination of tumor size are the problems in differentiating active malignant mass and changes in the surrounding tissue, as well as the lack of histomorphological correlation. Possible indications for volumetry of gastrointestinal masses in the assessment of neoadjuvant therapeutic concepts are under scientific evaluation. (orig./MG) [de

  13. Evolving practice patterns for the management of small renal masses in the USA.

    Science.gov (United States)

    Yang, Glen; Villalta, Jacqueline D; Meng, Maxwell V; Whitson, Jared M

    2012-10-01

    What's known on the subject? and What does the study add? Treatment options for small renal masses include radical nephrectomy (RN), partial nephrectomy (PN), ablation, and surveillance. PN provides equivalent oncological as RN for small tumours, but long-term outcomes for ablation and surveillance are poorly defined. Due to changing techniques and technology, treatment patterns for small renal masses are rapidly developing. Prior studies had analysed utilisation trends for PN and RN to 2006, revealing a relative rise in the rate of PN. However, overall treatment trends including surveillance and ablation had not been studied using a population-based cohort. It has become increasingly clear that RN is associated with greater renal and cardiovascular deterioration than nephron-sparing treatments. Thus, it is important to understand current population-based practice patterns for the treatment of small renal masses to assess whether practitioners are adhering to ever-changing principles in this field. The present study provides up-to-date treatment trends in the USA using a large population-based cohort. To describe the changing practice patterns in the management of small renal masses, including the use of surveillance and ablative techniques. All patients in the Surveillance, Epidemiology and End Results (SEER) registry treated for renal masses of ≤7 cm in diameter, from 1998 to 2008, were included for analysis. Annual trends in the use of surveillance, ablation, partial nephrectomy (PN), and radical nephrectomy (RN) were calculated. Multinomial logistic regression was used to determine the association of demographic and clinical characteristics with treatment method. In all, 48 148 patients from 17 registry sites with a mean age of 63.4 years were included for analysis. Between 1998 and 2008, for masses of vs 50%, 16% vs 33%, respectively) and ablation (1% vs 11%, 2% vs 9%, respectively). In multivariable analysis, later year of diagnosis, male gender, being

  14. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation.

    Science.gov (United States)

    Cong, Rui; Li, Jing; Guo, Song

    2017-02-01

    To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all Pbreast mass diagnoses. Copyright © 2016. Published by Elsevier B.V.

  15. Determination of iodine to compliment mass spectrometric measurements

    International Nuclear Information System (INIS)

    Hohorst, F.A.

    1994-11-01

    The dose of iodine-129 to facility personnel and the general public as a result of past, present, and future activities at DOE sites is of continuing interest, WINCO received about 160 samples annually in a variety of natural matrices, including snow, milk, thyroid tissue, and sagebrush, in which iodine-129 is determined in order to evaluate this dose, Currently, total iodine and the isotopic ratio of iodine-127 to iodine-129 are determined by mass spectrometry. These two measurements determine the concentration of iodine-129 in each sample, These measurements require at least 16 h of mass spectrometer operator time for each sample. A variety of methods are available which concentrate and determine small quantities of iodine. Although useful, these approaches would increase both time and cost. The objective of this effort was to determine total iodine by an alternative method in order to decrease the load on mass spectrometry by 25 to 50%. The preparation of each sample for mass spectrometric analysis involves a common step--collection of iodide on an ion exchange bed. This was the focal point of the effort since the results would be applicable to all samples

  16. A new method of determining the ejected mass of novae

    Energy Technology Data Exchange (ETDEWEB)

    Sparks, W.M.

    1994-12-31

    A new method of determining the ejected mass of novae based on simple, reasonable assumptions is presented. This method assumes that the remnant mass on the white dwarf is the same as that from the previous nova outburst. The hydrogen, helium, and metal abundances of the accreted material from the secondary must also be known or assumed. The white dwarf`s mass has a small effect because the amount of hydrogen consumed during the thermonuclear runaway only depends weakly upon this mass. If the composition of the ejecta and the time of the remnant shell burnout are determined from observations, then the ejected and remnant masses can be deduced. At present only a sharp decrease in the X-rays observed by ROSAT has been attributed to this remnant burnout and only for two novae: GQ Mus and V1974 Cyg. The ejected and remnant masses for these two novae are calculated. If other indicators of nova remnant burnout, such as a rapid decrease in high-ionization lines, can be identified, then this method could be applied to additional novae.

  17. Patterns and determinants of acute psychiatric readmissions | Behr ...

    African Journals Online (AJOL)

    Patterns and determinants of acute psychiatric readmissions. Graham Michael Behr, Cathy Christie, Neil Soderlund, Tennyson Lee. Abstract. Objectives. Deinstitutionalisation and shortage of psychiatric beds worldwide has led to extensive research into the risk factors and interventions associated with rapid and recurrent ...

  18. Clinico-Electroencephalography Pattern and Determinant of 2-year ...

    African Journals Online (AJOL)

    Clinico-Electroencephalography Pattern and Determinant of 2-year Seizure Control in Patients with Complex Partial Seizure Disorder in Kano, Northwestern ... Ability to predict seizure control on first diagnosis can be very useful in the management of patients with CPS. ... Data were analyzed using STATA version 10.

  19. Determination of ocular torsion by means of automatic pattern recognition

    NARCIS (Netherlands)

    Groen, E.L.; Bos, J.E.; Nacken, P.F.M.; Graaf, B. de

    1996-01-01

    A new, automatic method for determination of human ocular torsion (OT) was devel-oped based on the tracking of iris patterns in digitized video images. Instead of quanti-fying OT by means of cross-correlation of circular iris samples, a procedure commonly applied, this new method automatically

  20. Determination of ocular torsion by means of automatic pattern recognition

    NARCIS (Netherlands)

    Groen, Eric; Bos, Jelte E.; Nacken, Peter F M; De Graaf, Bernd

    A new, automatic method for determination of human ocular torsion (OT) was developed based on the tracking of iris patterns in digitized video images. Instead of quantifying OT by means of cross-correlation of circular iris samples, a procedure commonly applied, this new method automatically selects

  1. Mass and Position Determination in MEMS Resonant Mass Sensors: Theoretical and Experimental Investigation

    KAUST Repository

    Bouchaala, Adam M.; Nayfeh, Ali H.; Jaber, Nizar; Younis, Mohammad I.

    2016-01-01

    We present a method to determine accurately the position and mass of an entity attached to the surface of an electrostatically actuated clamped-clamped microbeam implemented as a mass sensor. In the theoretical investigation, the microbeam is modeled as a nonlinear Euler-Bernoulli beam and a perturbation technique is used to develop a closed-form expression for the frequency shift due to an added mass at a specific location on the microbeam surface. The experimental investigation was conducted on a microbeam made of Polyimide with a special lower electrode to excite both of the first and second modes of vibration. Using an ink-jet printer, we deposited droplets of polymers with a defined mass and position on the surface of the microbeam and we measured the shifts in its resonance frequencies. The theoretical predictions of the mass and position of the deposited droplets match well with the experimental measurements.

  2. Mass and Position Determination in MEMS Resonant Mass Sensors: Theoretical and Experimental Investigation

    KAUST Repository

    Bouchaala, Adam M.

    2016-12-05

    We present a method to determine accurately the position and mass of an entity attached to the surface of an electrostatically actuated clamped-clamped microbeam implemented as a mass sensor. In the theoretical investigation, the microbeam is modeled as a nonlinear Euler-Bernoulli beam and a perturbation technique is used to develop a closed-form expression for the frequency shift due to an added mass at a specific location on the microbeam surface. The experimental investigation was conducted on a microbeam made of Polyimide with a special lower electrode to excite both of the first and second modes of vibration. Using an ink-jet printer, we deposited droplets of polymers with a defined mass and position on the surface of the microbeam and we measured the shifts in its resonance frequencies. The theoretical predictions of the mass and position of the deposited droplets match well with the experimental measurements.

  3. Mass and position determination in MEMS mass sensors: a theoretical and an experimental investigation

    KAUST Repository

    Bouchaala, Adam M.

    2016-08-31

    We present a method to determine accurately the position and mass of an entity attached to the surface of an electrostatically actuated clamped-clamped microbeam implemented as a mass sensor. In the theoretical investigation, the microbeam is modeled as a nonlinear Euler-Bernoulli beam and a perturbation technique is used to develop a closed-form expression for the frequency shift due to an added mass at a specific location on the microbeam surface. The experimental investigation was conducted on a microbeam made of Polyimide with a special lower electrode to excite both of the first and second modes of vibration. Using an ink-jet printer, we deposited droplets of polymers with a defined mass and position on the surface of the microbeam and we measured the shifts in its resonance frequencies. The theoretical predictions of the mass and position of the deposited droplets match well with the experimental measurements.

  4. Lean body mass as a determinant of thyroid size

    NARCIS (Netherlands)

    Wesche, M. F.; Wiersinga, W. M.; Smits, N. J.

    1998-01-01

    Males have a larger thyroid gland than females, and this has been related to the difference in body weight. In view of the different body composition of men and women, we hypothesized that lean body mass is a better determinant of thyroid volume than body weight. A cross-sectional study in an area

  5. The Effect of Dietary Pattern and Body Mass Index on the Academic Performance of In-School Adolescents

    Science.gov (United States)

    Ogunsile, Seyi Elizabeth

    2012-01-01

    The main objective of this study was to determine the effects of dietary pattern and body mass index on the academic performance of in-school adolescents in Ekiti State. One hundred and twenty eight students (10-19 years) selected from three senior secondary schools in Ekiti State Nigeria, formed the participants for this study. Questionnaire was…

  6. Determination of balloon gas mass and revised estimates of drag and virtual mass coefficients

    Science.gov (United States)

    Robbins, E.; Martone, M.

    1993-01-01

    In support of the NASA Balloon Program, small-scale balloons were flown with varying lifting gas and total system mass. Instrument packages were developed to measure and record acceleration and temperature data during these tests. Top fitting and instrument payload accelerations were measured from launch to steady state ascent and through ballast drop transients. The development of the small lightweight self-powered Stowaway Special instrument packages is discussed along with mathematical models developed to determine gas mass, drag and virtual mass coefficients.

  7. A scan for models with realistic fermion mass patterns

    International Nuclear Information System (INIS)

    Bijnens, J.; Wetterich, C.

    1986-03-01

    We consider models which have no small Yukawa couplings unrelated to symmetry. This situation is generic in higher dimensional unification where Yukawa couplings are predicted to have strength similar to the gauge couplings. Generations have then to be differentiated by symmetry properties and the structure of fermion mass matrices is given in terms of quantum numbers alone. We scan possible symmetries leading to realistic mass matrices. (orig.)

  8. Precision and accuracy of β gauge for aerosol mass determinations

    International Nuclear Information System (INIS)

    Courtney, W.J.; Shaw, R.W.; Dzabay, T.G.

    1982-01-01

    Results of an experimental determination of the precision and the accuracy of a β-ray attenuation method for measurement of aerosol mass are presented. The instrumental precision for a short-term experiment was 25 μg for a 6.5-cm 2 deposit collected on approximately 1 mg/cm 2 Teflon filters; for a longer-term experiment the precision was 27 μg. The precision of the gravimetric determinations of aerosol deposits was 22 μg for Teflon filters weighed to 1 μg. Filter reorientation and air density changes that were able adversely to affect the β-ray attenuation results are discussed. β-ray attenuation results are in good agreement with gravimetric measurements on the same filter-collected aerosols. Using dichotomous samplers in Durham, NC, we collected 136 aerosol samples on Teflon filters in two size ranges. A regression line was calculated implicitly assuming errors in both measurements of mass. The 90% confidence intervals lay within 21 μg of the regression line for mean fine fraction aerosol mass loadings of 536 μg and within 19 μg of the regression line for mean coarse fraction aerosol mass loadings of 349 μg. Any bias between gravimetric and β-gauge mass measurements was found to be less than 5%

  9. Histone Deacetylase Inhibition Facilitates Massed Pattern-Induced Synaptic Plasticity and Memory

    Science.gov (United States)

    Pandey, Kiran; Sharma, Kaushik P.; Sharma, Shiv K.

    2015-01-01

    Massed training is less effective for long-term memory formation than the spaced training. The role of acetylation in synaptic plasticity and memory is now well established. However, the role of this important protein modification in synaptic plasticity induced by massed pattern of stimulation or memory induced by massed training is not well…

  10. High-Precision Direct Mass Determination of Unstable Isotopes

    CERN Multimedia

    2002-01-01

    The extension of systematic high-precision measurements of the nuclear mass to nuclei far from the valley of $\\beta$ stability is of great interest in nuclear physics and astrophysics. The mass, or binding energy, is a fundamental gross property and a key input parameter for nuclear matter calculations. It is also a sensitive probe for collective and single-particle effects in nuclear structure. \\\\ \\\\ For such purposes, nuclear masses need to be known to an accuracy of about 10$^{-7}$ (i.e. $\\Delta$M~$\\leq$~10~keV for A~=~100). To resolve a particular mass from its nuclear isomers and isobars, resolving power of 10$^6$ are often required. To achieve this, the ions delivered by the on-line mass separator ISOLDE are confined in a Penning quadrupole trap. This trap is placed in the very homogeneous and stable magnetic field of a superconducting magnet. Here, the cyclotron frequency and hence the mass are determined. \\\\ \\\\ The first measurements using this new technique have been completed for a long chain of Cs ...

  11. Saponification reaction system: a detailed mass transfer coefficient determination.

    Science.gov (United States)

    Pečar, Darja; Goršek, Andreja

    2015-01-01

    The saponification of an aromatic ester with an aqueous sodium hydroxide was studied within a heterogeneous reaction medium in order to determine the overall kinetics of the selected system. The extended thermo-kinetic model was developed compared to the previously used simple one. The reaction rate within a heterogeneous liquid-liquid system incorporates a chemical kinetics term as well as mass transfer between both phases. Chemical rate constant was obtained from experiments within a homogeneous medium, whilst the mass-transfer coefficient was determined separately. The measured thermal profiles were then the bases for determining the overall reaction-rate. This study presents the development of an extended kinetic model for considering mass transfer regarding the saponification of ethyl benzoate with sodium hydroxide within a heterogeneous reaction medium. The time-dependences are presented for the mass transfer coefficient and the interfacial areas at different heterogeneous stages and temperatures. The results indicated an important role of reliable kinetic model, as significant difference in k(L)a product was obtained with extended and simple approach.

  12. Three-dimensional image reconstruction. I. Determination of pattern orientation

    International Nuclear Information System (INIS)

    Blankenbecler, Richard

    2004-01-01

    The problem of determining the Euler angles of a randomly oriented three-dimensional (3D) object from its 2D Fraunhofer diffraction patterns is discussed. This problem arises in the reconstruction of a positive semidefinite 3D object using oversampling techniques. In such a problem, the data consist of a measured set of magnitudes from 2D tomographic images of the object at several unknown orientations. After the orientation angles are determined, the object itself can then be reconstructed by a variety of methods using oversampling, the magnitude data from the 2D images, physical constraints on the image, and then iteration to determine the phases

  13. Long-term patterns of body mass and stature evolution within the hominin lineage.

    Science.gov (United States)

    Will, Manuel; Pablos, Adrián; Stock, Jay T

    2017-11-01

    Body size is a central determinant of a species' biology and adaptive strategy, but the number of reliable estimates of hominin body mass and stature have been insufficient to determine long-term patterns and subtle interactions in these size components within our lineage. Here, we analyse 254 body mass and 204 stature estimates from a total of 311 hominin specimens dating from 4.4 Ma to the Holocene using multi-level chronological and taxonomic analytical categories. The results demonstrate complex temporal patterns of body size variation with phases of relative stasis intermitted by periods of rapid increases. The observed trajectories could result from punctuated increases at speciation events, but also differential proliferation of large-bodied taxa or the extinction of small-bodied populations. Combined taxonomic and temporal analyses show that in relation to australopithecines, early Homo is characterized by significantly larger average body mass and stature but retains considerable diversity, including small body sizes. Within later Homo , stature and body mass evolution follow different trajectories: average modern stature is maintained from ca 1.6 Ma, while consistently higher body masses are not established until the Middle Pleistocene at ca 0.5-0.4 Ma, likely caused by directional selection related to colonizing higher latitudes. Selection against small-bodied individuals (less than 40 kg; less than 140 cm) after 1.4 Ma is associated with a decrease in relative size variability in later Homo species compared with earlier Homo and australopithecines. The isolated small-bodied individuals of Homo naledi ( ca 0.3 Ma) and Homo floresiensis ( ca 100-60 ka) constitute important exceptions to these general patterns, adding further layers of complexity to the evolution of body size within the genus Homo . At the end of the Late Pleistocene and Holocene, body size in Homo sapiens declines on average, but also extends to lower limits not seen in

  14. Heat-And-Mass Transfer Relationship to Determine Shear Stress in Tubular Membrane Systems

    DEFF Research Database (Denmark)

    Ratkovich, Nicolas Rios; Nopens, Ingmar

    2012-01-01

    The main drawback of Membrane Bioreactors (MBRs) is the fouling of the membrane. One way to reduce this fouling is through controlling the hydrodynamics of the two-phase slug flow near the membrane surface. It has been proven in literature that the slug flow pattern has a higher scouring effect...... to remove particulates due to the high shear rates and high mass transfer between the membrane surface and the bulk region. However, to calculate the mass transfer coefficient in an efficient and accurate way is not straightforward. Indeed, for accurate determination, numerous complex experimental...

  15. Determining mass-to-light ratios in elliptical galaxies

    International Nuclear Information System (INIS)

    Mathews, W.G.

    1988-01-01

    If the endstate of cooling hot gas in elliptical galaxies is a population of optically dark, low-mass stars near the galactic cores, the mass-to-light ratio could be expected to vary significantly with projected radius. No strong variation in M/L is observed. To investigate the sensitivity and reliability of observational mass-to-light determinations for a variety of galactic parameters, model galaxies having de Vaucouleurs profiles (but with central cores and outer cutoffs), variable velocity ellipsoid structure, and extended dark halos are constructed. Spurious radial variations in M/L can occur when none are present if the properties of the galactic models are processed similar to observational data. Conversely, when a population of diffuse dark stellar matter is added near the galactic cores, large gradients in M/L can escape detection. However, the magnitude of the central velocity dispersion and its variation with projected radius within the effective radius both suggest that a component of dark stars is unlikely to be more massive than about 30 times the core mass of luminous stars. This restriction is important in establishing the initial mass function of stars in elliptical galaxies and the history of winds and cooling inflows in the interstellar medium. 35 references

  16. Myofiber metabolic type determination by mass spectrometry imaging

    OpenAIRE

    Théron, Laetitia; Vénien, Annie; Pujos-Guillot, Estelle; Astruc, Thierry; Chambon, Christophe

    2017-01-01

    In muscle imaging, myofiber type determination is of great importance to better understand biological mechanisms related to skeletal muscle changes associated with pathologies. However, reference methods (histo-enzymology and immunohistochemistry) require serial-cross sections, and several days from the sampling to the results of image analysis. In this work, a strategy based on MALDI-Mass Spectrometry Imaging was developed as an alternative to the classical methods for myofiber metabolic typ...

  17. Nuclear equipment to determine soil and water mass attenuation coefficients

    International Nuclear Information System (INIS)

    Zucchi, O.L.A.D.; Nascimento Filho, V.F. do

    1984-01-01

    The feasibility of substituting the monochannel gamma spectrometer, traditionally used in the gamma ray attenuation technique, for a less sophisticated and less expensive system of integral counting is studied. The proposed system can be operated by a non-specialized person. Three detection systems were used in the determination of the mass attenuation coefficients for different types of soil and for water. (M.A.C.) [pt

  18. Determining the minimum mass and cost of a magnetic refrigerator

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Smith, Anders; Bahl, Christian Robert Haffenden

    2011-01-01

    An expression is determined for the mass of the magnet and magnetocaloric material needed for a magnetic refrigerator and these are determined using numerical modeling for both parallel plate and packed sphere bed regenerators as function of temperature span and cooling power. As magnetocaloric......, respectively, the cheapest 100 W parallel plate refrigerator with a temperature span of 20 K using Gd and a Halbach magnet has 0.8 kg of magnet, 0.3 kg of Gd and a cost of $35. Using the constant material reduces this cost to $25. A packed sphere bed refrigerator with the constant material costs $7. It is also...

  19. Isotope determination of sulfur by mass spectrometry in soil samples

    Directory of Open Access Journals (Sweden)

    Alexssandra Luiza Rodrigues Molina Rossete

    2012-12-01

    Full Text Available Sulphur plays an essential role in plants and is one of the main nutrients in several metabolic processes. It has four stable isotopes (32S, 33S, 34S, and 36S with a natural abundance of 95.00, 0.76, 4.22, and 0.014 in atom %, respectively. A method for isotopic determination of S by isotope-ratio mass spectrometry (IRMS in soil samples is proposed. The procedure involves the oxidation of organic S to sulphate (S-SO4(2-, which was determined by dry combustion with alkaline oxidizing agents. The total S-SO4(2- concentration was determined by turbidimetry and the results showed that the conversion process was adequate. To produce gaseous SO2 gas, BaSO4 was thermally decomposed in a vacuum system at 900 ºC in the presence of NaPO3. The isotope determination of S (atom % 34S atoms was carried out by isotope ratio mass spectrometry (IRMS. In this work, the labeled material (K2(34SO4 was used to validate the method of isotopic determination of S; the results were precise and accurate, showing the viability of the proposed method.

  20. Neutrino mass hierarchy determination for θ13 = 0

    International Nuclear Information System (INIS)

    Gandhi, Raj; Ghoshal, Pomita; Goswami, Srubabati; Sankar, S. Uma

    2010-01-01

    We examine the possibility of determining the neutrino mass hierarchy in the limit θ 13 = 0 using atmospheric neutrinos as the source. In this limit, θ 13 driven matter effects are absent so independent measurements of Δ 31 and Δ 32 can, in principle, lead to hierarchy determination. Since their difference is Δ 21 , one needs an experimental arrangement where Δ 21 L/E > or approx. 1 can be achieved. This can be satisfied by atmospheric neutrinos which have a large range of L and E. Still, we find that hierarchy determination in the θ 13 = 0 limit with atmospheric neutrinos is not a realistic possibility, even in conjunction with a beam experiment like T2K or NOνA. We discuss why, and also reiterate the general conditions for hierarchy determination if θ 13 = 0.

  1. Neutrino mass hierarchy determination via atmospheric neutrinos with future detectors

    International Nuclear Information System (INIS)

    Gandhi, Raj; Ghoshal, Pomita; Goswami, Srubabati; Mehta, Poonam; Sankar, S Uma; Shalgar, Shashank

    2008-01-01

    The issue of determining the neutrino mass hierarchy is one of the outstanding questions in neutrino physics. We consider the potential of hierarchy determination using atmospheric neutrinos as the source in three different proposed future detectors: A large Iron Calorimeter detector, a megaton Water Cerenkov detector and a large-mass Liquid Argon detector. If the mixing angle θ 13 is about 10 deg. (close to CHOOZ upper bound), the hierarchy sensitivity is essentially determined by resonant matter effects. To maximize the potential of these effects in atmospheric neutrinos, charge discrimination capability in the detector is desirable. Hence, detectors with this capability have an advantage in hierarchy determination. We compare and contrast the performance of the above three detectors in this respect. We perform a realistic analysis of the above future detectors for atmospheric neutrinos and show that it is possible to achieve a significant hierarchy sensitivity if the detector characteristics are favourable. Note: The abstract has been modified from its original form to incorporate suggestions received during the conference. The poster is being submitted in its original form.

  2. Determine the Foot Strike Pattern Using Inertial Sensors

    Directory of Open Access Journals (Sweden)

    Tzyy-Yuang Shiang

    2016-01-01

    Full Text Available From biomechanical point of view, strike pattern plays an important role in preventing potential injury risk in running. Traditionally, strike pattern determination was conducted by using 3D motion analysis system with cameras. However, the procedure is costly and not convenient. With the rapid development of technology, sensors have been applied in sport science field lately. Therefore, this study was designed to determine the algorithm that can identify landing strategies with a wearable sensor. Six healthy male participants were recruited to perform heel and forefoot strike strategies at 7, 10, and 13 km/h speeds. The kinematic data were collected by Vicon 3D motion analysis system and 2 inertial measurement units (IMU attached on the dorsal side of both shoes. The data of each foot strike were gathered for pitch angle and strike index analysis. Comparing the strike index from IMU with the pitch angle from Vicon system, our results showed that both signals exhibited highly correlated changes between different strike patterns in the sagittal plane (r=0.98. Based on the findings, the IMU sensors showed potential capabilities and could be extended beyond the context of sport science to other fields, including clinical applications.

  3. A knowledge based method for nuclear plant loading pattern determination

    International Nuclear Information System (INIS)

    Dauboin, P.

    1990-01-01

    This paper deals with the design of a knowledge based system for solving an industrial problem which occurs in nuclear fuel management. The problem lies in determining satisfactory loading patterns for nuclear plants. Its primary feature consists in the huge search space involved. Conventional resolution processes are formally defined and analyzed: there is no general algorithm which guarantees to always provide a reasonable solution in each situation. We propose a new approach to solve this constrained search problem using domain-specific knowledge and general constraint-based heuristics. During a preprocessing step, a problem dependent search algorithm is designed. This procedure is then automatically implemented in FORTRAN. The generated routines have proved to be very efficient finding solutions which could not have been provided using logic programming. A prototype expert system has already been applied to actual reload pattern searches. While combining efficiency and flexibility, this knowledge based system enables human experts to rapidly match new constraints and requirements

  4. Determination of plutonium in soils by mass spectrometry

    International Nuclear Information System (INIS)

    Storms, H.A.; Carlson, D.C.; Hunter, F.F.

    1974-01-01

    A procedure is described in which mass spectrometry is utilized for the determination of plutonium in soils. Using this procedure we have measured plutonium isotopic compositions at concentrations as low as 2 x 10 -14 grams Pu per gram soil. A thermal ionization source with canoe-shaped rhenium filament, is utilized in the mass spectrometer. The plutonium, when loaded onto the filament, is contained in a single Dowex-1 resin bead which is about 350 micrometers in diameter. Concentrating the plutonium within this single bead is a key step in the procedure and produces a relatively clean plutonium fraction. The resin bead also serves as an effective diffusion barrier such that the plutonium is prevented from being removed with the lower boiling impurities. The Pu remains in the bead until the temperature is sufficiently high for efficient production of Pu + ions. Plutonium ionization efficiencies as high as 2.5 percent have been measured

  5. An analysis of whorl patterns for determination of hand.

    Science.gov (United States)

    Kapoor, Neeti; Badiye, Ashish

    2015-05-01

    On crime scenes, whole set of the ten digit fingerprints are rarely found and usually chance prints in the form of single digit fingerprint are encountered. Determination of hand (Right or left) can be of vital importance to reduce the burden on the investigator and may thereby aid in fixation of absolute identity of the donor. In the present investigation, 500 randomly selected and bilateral rolled fingerprints of 250 healthy, consenting adult subjects of a central Indian (Marathi) population with whorl patterns were examined to determine the hand. It was found that by studying various parameters like; slope of apex ridges (towards right, left or absent), rotation of innermost ridges (either clockwise, anti-clockwise or absent), angle formed at both sides of core, position of the perpendicular bisector on the delta line (with respect to core), ridge tracing (outer, inner or meeting), higher ridge count, angle between deltas and core (at deltas), direction of the pattern (tilting/inclination) and distance between the deltas & the core; it is possible to successfully determine the hand of the print. Applying chi-square test, the results were found to be statistically significant at p < 0.01 levels. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  6. The pattern of anthropogenic signal emergence in Greenland Ice Sheet surface mass balance

    NARCIS (Netherlands)

    Fyke, J.G.; Vizcaino, M.; Lipscomb, W.H.

    2014-01-01

    Surface mass balance (SMB) trends influence observed Greenland Ice Sheet (GrIS) mass loss, but the component of these trends related to anthropogenic forcing is unclear. Here we study the simulated spatial pattern of emergence of an anthropogenically derived GrIS SMB signal between 1850 and 2100

  7. Determination of trace elements by resonant ionization mass spectrometry (RIMS)

    International Nuclear Information System (INIS)

    Ruster, W.; Ames, F.; Rehklau, D.; Mang, M.; Muehleck, C.; Rimke, H.; Sattelberger, P.; Herrmann, G.; Trautmann, N.; Kluge, H.J.; Otten, E.W.

    1988-01-01

    A resonant ionization mass spectrometer has been developed as an analytical tool for the detection of trace elements, especially of plutonium and other radionuclides. The sample, deposited on a rhenium filament, is evaporated by electrical heating and the atoms of the element under investigation are selectively ionized by laser light delivered from three dye lasers pumped by a copper vapour laser. The resulting photoions are detected in a time-of-flight spectrometer with a channelplate detector. For plutonium a mass resolution of M/ΔM=1500 was obtained and an overall detection efficiency of 4x10 -6 was determined for stepwise excitation and ionization via autoionizing states. With a laser light bandwidth of 3-5 GHz neighbouring isotopes could be suppressed by a factor of 20 due to isotope shifts in the excitation transitions. The isotope composition of synthetic samples was measured and good agreement was found with mass spectroscopic results. The influence of the hyperfine structure on the isotope ratios is discussed. (orig.)

  8. Characterization of the fracturation of rock masses for determining flow

    International Nuclear Information System (INIS)

    Derlich, S.

    1984-02-01

    Flow in a rock mass is the consequence of the permeability of the rock, which can be roughly separated into matrix permeability and fissure permeability. In crystalline rocks fissure permeability is dominant, especially where the rocks are extensively fractured. It is thus essential, by means of studies either at the surface or underground, to characterize the volume fracturation in the mass considered. The purpose of this paper is to illustrate the methodology for analysing fracturation at a site by the studies performed on the granite mass of Auriat in the French Massif Central. A number of geology laboratories have participated in this study and a broad spectrum of observations has been made which can be used for determining the various stages of a study with a view to selection of a site, the advantages and limitations of each method or study plan and additional methods which need to be used for gaining as complete a picture as possible of the fracturation. A brief examination of the results obtained at Auriat enables the relative advantages of using these various methods at a particular site to be compared

  9. Rugae pattern determination in periodontitis patients: A descriptive study

    Directory of Open Access Journals (Sweden)

    Vikas Jindal

    2016-01-01

    Full Text Available Background: Forensic sciences, a well-established branch in the field of medicine and dentistry always aids in revealing person identity by various methods. Commonly used techniques are analysis of teeth, fingerprints, and DNA comparison, which allowing fast and secure identification processes. However, these techniques cannot always be applied, in some cases, it is necessary to apply different and less known techniques. Aim: The aim of the present study was to determine the uniqueness of palatal rugae pattern in Himachal ethnicity population and whether there is any relation between pattern of rugae in gingivitis, chronic periodontitis, and aggressive periodontitis. Settings and Design: The present study includes maxillary impressions cast in dental stone of patients attending and were divided into three groups of gingivitis, aggressive periodontitis, and chronic periodontitis. Materials and Methods: In our study, palatal rugae pattern were then evaluated on maxillary casts for the number and shape using calcorrugoscopy. Statistical Analysis: Comparison of means of number of rugae in three groups was done using independent sample t-test, and comparison of mean of different shapes was done employing analysis of variance. The level of significance was fixed at P< 0.05. Results: The most prevalent palatal rugae shape in aggressive periodontitis was found to be angle followed by Sinuous and in chronic and aggressive periodontitis was sinuous followed by line pattern. Conclusions: The differences in rugae shape between the three groups may be attributed to genetic factors, disease progression, and recent shared ancestry has probably rendered their differences to moderate levels.

  10. Determination of root activity pattern in citrus under irrigation (Tumbaco)

    International Nuclear Information System (INIS)

    Aizaga, Jorge; Calvache, Marcelo

    1992-01-01

    This experiment was carried out in Tumbaco, province of Pichincha, from january to april 1991. The objective of the study was to determine the root activity patterns in citrus. Tangerine plants of two varieties(common and willowleaf on rugged lemon pattern) three years old were used. A solution of Na H 2 PO 4 labeled with 3 2 P was applied at four distances: 0.30, 0.60, 0.90 and 1.20 m, distributed in a circle around the trees. Leaf samples were taken at 20,37 and 64 days after application and 3 2 P activity was determined. Statistical analysis of the data showed a highly significant variation between treatments and two ranges of significance were defined: the first one included the treatments at 0.30 and 0.60 m, and the second, the treatments at 0.90 and 1.20 m. At the same time soil moisture data were collected. These data demonstrated the relation between soil moisture and root activity and efficiency. With the obtained information it can be concluded that in trees over three years old, and in Tumbaco conditions of citrus management and ecology, the best distance to apply fertilizer is in circles located at 0.30 to 0.60 . from the trunck of tree

  11. Image resolution influence on determination of resin injection rock mass

    Science.gov (United States)

    Wang, Weixing; Hakami, Eva

    2006-01-01

    In the context of nuclear waste repositories, an important approach to understanding brittle rock mass behavior to integrate new and powerful observational and numerical methods with multi-functional 3-D imaging and visualization techniques. Since 1994, Swedish Nuclear Fuel and Waste Management Company (SKB) have identified the need for a better understanding of radionuclide transport and retention processes in fractured rock. As a cooperation project between Sweden and China, we sampled a number of rock specimens for analyze rock fracture network by optical image technique. The samples are resin injected, in which way; opened fractures can be seen clearly by means of UV (Ultraviolet) light illumination. In the study period, we used different optical focuses to obtain the images from the same samples; we found that Image resolution influences on porosity determination of resin injected rock mass. This paper presents and discusses the six issues based on our research results: (1) Fracture porosity increases as camera focus distance decreases; (2) Porosity increases as illumination increases in resin injected fracture images; (3) To roughly estimate the porosity, the low resolution image can be used; (4) To collect more details of fracture information, the high resolution image is needed; (5) The resolution of image should be determined based on the aim of fracture analysis; (6) To acquire high resolution image, constructing a special illumination (standard) box maybe helpful to avoid light reflection and diffusion.

  12. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Cong, Rui, E-mail: congrui2684@163.com; Li, Jing, E-mail: lijing@sj-hospital.org; Guo, Song, E-mail: 21751735@qq.com

    2017-02-15

    Highlights: • Qualitative SWE classification proposed here was significantly better than quantitative SWE parameters. • Qualitative classification proposed here was better than the classification proposed before. • Qualitative classification proposed here could obtain higher specificity without a loss of sensitivity. - Abstract: Objectives: To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. Methods: From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. Results: With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P < 0.05). When applying Qual1

  13. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation

    International Nuclear Information System (INIS)

    Cong, Rui; Li, Jing; Guo, Song

    2017-01-01

    Highlights: • Qualitative SWE classification proposed here was significantly better than quantitative SWE parameters. • Qualitative classification proposed here was better than the classification proposed before. • Qualitative classification proposed here could obtain higher specificity without a loss of sensitivity. - Abstract: Objectives: To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. Methods: From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. Results: With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P < 0.05). When applying Qual1

  14. Energy determines broad pattern of plant distribution in Western Himalaya.

    Science.gov (United States)

    Panda, Rajendra M; Behera, Mukunda Dev; Roy, Partha S; Biradar, Chandrashekhar

    2017-12-01

    Several factors describe the broad pattern of diversity in plant species distribution. We explore these determinants of species richness in Western Himalayas using high-resolution species data available for the area to energy, water, physiography and anthropogenic disturbance. The floral data involves 1279 species from 1178 spatial locations and 738 sample plots of a national database. We evaluated their correlation with 8-environmental variables, selected on the basis of correlation coefficients and principal component loadings, using both linear (structural equation model) and nonlinear (generalised additive model) techniques. There were 645 genera and 176 families including 815 herbs, 213 shrubs, 190 trees, and 61 lianas. The nonlinear model explained the maximum deviance of 67.4% and showed the dominant contribution of climate on species richness with a 59% share. Energy variables (potential evapotranspiration and temperature seasonality) explained the deviance better than did water variables (aridity index and precipitation of the driest quarter). Temperature seasonality had the maximum impact on the species richness. The structural equation model confirmed the results of the nonlinear model but less efficiently. The mutual influences of the climatic variables were found to affect the predictions of the model significantly. To our knowledge, the 67.4% deviance found in the species richness pattern is one of the highest values reported in mountain studies. Broadly, climate described by water-energy dynamics provides the best explanation for the species richness pattern. Both modeling approaches supported the same conclusion that energy is the best predictor of species richness. The dry and cold conditions of the region account for the dominant contribution of energy on species richness.

  15. Hybrid expert system implementation to determine core reload patterns

    International Nuclear Information System (INIS)

    Greek, K.J.; Robinson, A.H.

    1989-01-01

    Determining reactor reload fuel patterns is a computationally intensive problem solving process for which automation can be of significant benefit. Often much effort is expended in the search for an optimal loading. While any modern programming language could be used to automate solution, the specialized tools of artificial intelligence (AI) are the most efficient means of introducing the fuel management expert's knowledge into the search for an optimum reload pattern. Prior research in pressurized water reactor refueling strategies developed FORTRAN programs that automated an expert's basic knowledge to direct a search for an acceptable minimum peak power loading. The dissatisfaction with maintenance of compiled knowledge in FORTRAN programs has served as the motivation for the development of the SHUFFLE expert system. SHUFFLE is written in Smalltalk, an object-oriented programming language, and evaluates loadings as it generates them using a two-group, two-dimensional nodal power calculation compiled in a personal computer-based FORTRAN. This paper reviews the object-oriented representation developed to solve the core reload problem with an expert system tool and its operating prototype, SHUFFLE

  16. A precise determination of the top-quark pole mass

    International Nuclear Information System (INIS)

    Wang, Sheng-Quan; Wu, Xing-Gang; Si, Zong-Guo; Brodsky, Stanley J.

    2018-01-01

    The Principle of Maximum Conformality (PMC) provides a systematic way to eliminate the renormalization scheme and renormalization scale uncertainties for high-energy processes. We have observed that by applying PMC scale setting, one obtains comprehensive and self-consistent pQCD predictions for the top-quark pair total cross section and the top-quark pair forward-backward asymmetry in agreement with the measurements at the Tevatron and LHC. As a step forward, in the present paper, we determine the top-quark pole mass via a detailed comparison of the top-quark pair cross section with the measurements at the Tevatron and LHC. The results for the top-quark pole mass are m t = 174.6 +3.1 -3.2 GeV for the Tevatron with √(S) = 1.96 TeV, m t = 173.7 ± 1.5 and 174.2 ± 1.7 GeV for the LHC with √(S) = 7 and 8 TeV, respectively. Those predictions agree with the average, 173.34 ± 0.76 GeV, obtained from various collaborations via direct measurements. The consistency of the pQCD predictions using the PMC with all of the collider measurements at different energies provides an important verification of QCD. (orig.)

  17. A precise determination of the top-quark pole mass

    Science.gov (United States)

    Wang, Sheng-Quan; Wu, Xing-Gang; Si, Zong-Guo; Brodsky, Stanley J.

    2018-03-01

    The Principle of Maximum Conformality (PMC) provides a systematic way to eliminate the renormalization scheme and renormalization scale uncertainties for high-energy processes. We have observed that by applying PMC scale setting, one obtains comprehensive and self-consistent pQCD predictions for the top-quark pair total cross section and the top-quark pair forward-backward asymmetry in agreement with the measurements at the Tevatron and LHC. As a step forward, in the present paper, we determine the top-quark pole mass via a detailed comparison of the top-quark pair cross section with the measurements at the Tevatron and LHC. The results for the top-quark pole mass are m_t=174.6^{+3.1}_{-3.2} GeV for the Tevatron with √{S}=1.96 TeV, m_t=173.7± 1.5 and 174.2± 1.7 GeV for the LHC with √{S} = 7 and 8 TeV, respectively. Those predictions agree with the average, 173.34± 0.76 GeV, obtained from various collaborations via direct measurements. The consistency of the pQCD predictions using the PMC with all of the collider measurements at different energies provides an important verification of QCD.

  18. Fractal pattern growth simulation in electrodeposition and study of the shifting of center of mass

    International Nuclear Information System (INIS)

    Shaikh, Yusuf H.; Khan, A.R.; Pathan, J.M.; Patil, Aruna; Behere, S.H.

    2009-01-01

    We presented simulation of fractal pattern in electrodeposition (Diffusion limited aggregation) using concept of off lattice walk. It is seen that the growth patterns are based on a parameter called 'bias'. This parameter 'bias' controls the growth of patterns similar to that of electric field in electrodeposition technique. In present study the fractal patterns are grown for different values of 'bias'. Dendritic patterns grown at lower value of 'bias' comprises open structure and show limited branching. As the bias is increased the growth tends to be dense and show more crowded branching. Box counting was implemented to calculate fractal dimension. The structural and textural complexities and are compared with the experimental observations. It was also noted that in the evolution of DLA patterns, the center of mass of the growth is shifted slightly. We tracked the position of the center of mass of simulated electro deposits under different electric field conditions. The center of mass exhibit random walk like patterns and it wanders around the origin or the starting point of the growth.

  19. Fossils and living taxa agree on patterns of body mass evolution: a case study with Afrotheria.

    Science.gov (United States)

    Puttick, Mark N; Thomas, Gavin H

    2015-12-22

    Most of life is extinct, so incorporating some fossil evidence into analyses of macroevolution is typically seen as necessary to understand the diversification of life and patterns of morphological evolution. Here we test the effects of inclusion of fossils in a study of the body size evolution of afrotherian mammals, a clade that includes the elephants, sea cows and elephant shrews. We find that the inclusion of fossil tips has little impact on analyses of body mass evolution; from a small ancestral size (approx. 100 g), there is a shift in rate and an increase in mass leading to the larger-bodied Paenungulata and Tubulidentata, regardless of whether fossils are included or excluded from analyses. For Afrotheria, the inclusion of fossils and morphological character data affect phylogenetic topology, but these differences have little impact upon patterns of body mass evolution and these body mass evolutionary patterns are consistent with the fossil record. The largest differences between our analyses result from the evolutionary model, not the addition of fossils. For some clades, extant-only analyses may be reliable to reconstruct body mass evolution, but the addition of fossils and careful model selection is likely to increase confidence and accuracy of reconstructed macroevolutionary patterns. © 2015 The Authors.

  20. Direct molecular mass determination of trehalose monomycolate from 11 species of mycobacteria by MALDI-TOF mass spectrometry.

    Science.gov (United States)

    Fujita, Yukiko; Naka, Takashi; Doi, Takeshi; Yano, Ikuya

    2005-05-01

    Direct estimation of the molecular mass of single molecular species of trehalose 6-monomycolate (TMM), a ubiquitous cell-wall component of mycobacteria, was performed by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. When less than 1 microg TMM was analysed by MALDI-TOF mass spectrometry, quasimolecular ions [M+Na]+ of each molecular species were demonstrated and the numbers of carbons and double bonds (or cyclopropane rings) were determined. Since the introduction of oxygen atoms such as carbonyl, methoxy and ester groups yielded the appropriate shift of mass ions, the major subclasses of mycolic acid (alpha, methoxy, keto and wax ester) were identified without resorting to hydrolytic procedures. The results showed a marked difference in the molecular species composition of TMM among mycobacterial species. Unexpectedly, differing from other mycoloyl glycolipids, TMM from Mycobacterium tuberculosis showed a distinctive mass pattern, with abundant odd-carbon-numbered monocyclopropanoic (or monoenoic) alpha-mycolates besides dicyclopropanoic mycolate, ranging from C75 to C85, odd- and even-carbon-numbered methoxymycolates ranging from C83 to C94 and even- and odd-carbon-numbered ketomycolates ranging from C83 to C90. In contrast, TMM from Mycobacterium bovis (wild strain and BCG substrains) possessed even-carbon-numbered dicyclopropanoic alpha-mycolates. BCG Connaught strain lacked methoxymycolates almost completely. These results were confirmed by MALDI-TOF mass analysis of mycolic acid methyl esters liberated by alkaline hydrolysis and methylation of the original TMM. Wax ester-mycoloyl TMM molecular species were demonstrated for the first time as an intact form in the Mycobacterium avium-intracellulare group, M. phlei and M. flavescens. The M. avium-intracellulare group possessed predominantly C85 and C87 wax ester-mycoloyl TMM, while M. phlei and the rapid growers tested contained C80, C81, C82 and C83 wax ester

  1. Adolescent dietary patterns in Fiji and their relationships with standardized body mass index.

    Science.gov (United States)

    Wate, Jillian T; Snowdon, Wendy; Millar, Lynne; Nichols, Melanie; Mavoa, Helen; Goundar, Ramneek; Kama, Ateca; Swinburn, Boyd

    2013-04-09

    Obesity has been increasing in adolescents in Fiji and obesogenic dietary patterns need to be assessed to inform health promotion. The objective of this study was to identify the dietary patterns of adolescents in peri-urban Fiji and determine their relationships with standardized body mass index (BMI-z). This study analysed baseline measurements from the Pacific Obesity Prevention In Communities (OPIC) Project. The sample comprised 6,871 adolescents aged 13-18 years from 18 secondary schools on the main island of Viti Levu, Fiji. Adolescents completed a questionnaire that included diet-related variables; height and weight were measured. Descriptive statistics and regression analyses were conducted to examine the associations between dietary patterns and BMI-z, while controlling for confounders and cluster effect by school. Of the total sample, 24% of adolescents were overweight or obese, with a higher prevalence among Indigenous Fijians and females. Almost all adolescents reported frequent consumption of sugar sweetened beverages (SSB) (90%) and low intake of fruit and vegetables (74%). Over 25% of participants were frequent consumers of takeaways for dinner, and either high fat/salt snacks, or confectionery after school. Nearly one quarter reported irregular breakfast (24%) and lunch (24%) consumption on school days, while fewer adolescents (13%) ate fried foods after school. IndoFijians were more likely than Indigenous Fijians to regularly consume breakfast, but had a high unhealthy SSB and snack consumption.Regular breakfast (p<0.05), morning snack (p<0.05) and lunch (p<0.05) consumption were significantly associated with lower BMI-z. Consumption of high fat/salt snacks, fried foods and confectionery was lower among participants with higher BMI-z. This study provides important information about Fijian adolescents' dietary patterns and associations with BMI-z. Health promotion should target reducing SSB, increasing fruit and vegetables consumption, and

  2. Quantitative interpretation of tracks for determination of body mass.

    Directory of Open Access Journals (Sweden)

    Tom Schanz

    Full Text Available To better understand the biology of extinct animals, experimentation with extant animals and innovative numerical approaches have grown in recent years. This research project uses principles of soil mechanics and a neoichnological field experiment with an African elephant to derive a novel concept for calculating the mass (i.e., the weight of an animal from its footprints. We used the elephant's footprint geometry (i.e., vertical displacements, diameter in combination with soil mechanical analyses (i.e., soil classification, soil parameter determination in the laboratory, Finite Element Analysis (FEA and gait analysis for the back analysis of the elephant's weight from a single footprint. In doing so we validated the first component of a methodology for calculating the weight of extinct dinosaurs. The field experiment was conducted under known boundary conditions at the Zoological Gardens Wuppertal with a female African elephant. The weight of the elephant was measured and the walking area was prepared with sediment in advance. Then the elephant was walked across the test area, leaving a trackway behind. Footprint geometry was obtained by laser scanning. To estimate the dynamic component involved in footprint formation, the velocity the foot reaches when touching the subsoil was determined by the Digital Image Correlation (DIC technique. Soil parameters were identified by performing experiments on the soil in the laboratory. FEA was then used for the backcalculation of the elephant's weight. With this study, we demonstrate the adaptability of using footprint geometry in combination with theoretical considerations of loading of the subsoil during a walk and soil mechanical methods for prediction of trackmakers weight.

  3. Anthropometric parameters: weight height, body mass index and mammary volume in relationship with the mammographic pattern

    International Nuclear Information System (INIS)

    Perez-Candela, V.; Busto, C.; Avila, R.; Marrero, M. G.; Liminana, J. M.; Orengo, J. C.

    2001-01-01

    A prospective study to attempt to relate the anthropometric parameters of height, weight, body mass index as well as age with the mammographic patterns obtained for the patients and obtain an anthropometric profile was carried out. The study was performed in 1.000 women who underwent a mammography in cranial-caudal and medial lateral oblique projection of both breasts, independently of whether they were screened or diagnosed. Prior to the performance of the mammography, weight and height were obtained, and this was also performed by the same technicians, and the patient were asked their bra size to deduce breast volume. With the weight, the body mass index of Quetelet was calculated (weight [kg]/height''2 (ml). After reading the mammography, the patient was assigned to one of the four mammographic patterns considered in the BIRADS (Breast Imaging Reporting and Data System) established by the ACR (American College of Radiology): type I (fat). type II (disperse fibroglandular densities), type III (fibroglandular densities distributed heterogeneously), type 4 (dense). The results were introduced into a computer database and the SPSS 8.0 statistical program was applied, using the statistical model of multivariant logistic regression. In women under 40 years, with normal weight, the dense breast pattern accounted for 67.8% and as the body mass index (BMI) increased, this pattern decreased to 25.1%. The fat pattern is 20% and as the BMI increases, this increased to 80%. In 40-60 year old women with normal weight, the dense pattern accounts for 44% and decreases to 20.9% in the grades II, III and IV obese. The fat pattern is 11.1% and increases to 53.7% in the grade II, III and IV obese. In women over 60 with normal, the dense pattern accounts for 19.3% and and decreases to 13% in the grade III obese. The fat pattern is 5.3% and increases to 20.2% in the grade iii of obesity. As age increases, the probability of presenting a mammographic pattern with a fat image in the

  4. On the Bar Pattern Speed Determination of NGC 3367

    Science.gov (United States)

    Gabbasov, R. F.; Repetto, P.; Rosado, M.

    2009-09-01

    An important dynamic parameter of barred galaxies is the bar pattern speed, Ω P . Among several methods that are used for the determination of Ω P , the Tremaine-Weinberg method has the advantage of model independence and accuracy. In this work, we apply the method to a simulated bar including gas dynamics and study the effect of two-dimensional spectroscopy data quality on robustness of the method. We added white noise and a Gaussian random field to the data and measured the corresponding errors in Ω P . We found that a signal to noise ratio in surface density ~5 introduces errors of ~20% for the Gaussian noise, while for the white noise the corresponding errors reach ~50%. At the same time, the velocity field is less sensitive to contamination. On the basis of the performed study, we applied the method to the NGC 3367 spiral galaxy using Hα Fabry-Pérot interferometry data. We found Ω P = 43 ± 6 km s-1 kpc-1 for this galaxy.

  5. ON THE BAR PATTERN SPEED DETERMINATION OF NGC 3367

    International Nuclear Information System (INIS)

    Gabbasov, R. F.; Repetto, P.; Rosado, M.

    2009-01-01

    An important dynamic parameter of barred galaxies is the bar pattern speed, Ω P . Among several methods that are used for the determination of Ω P , the Tremaine-Weinberg method has the advantage of model independence and accuracy. In this work, we apply the method to a simulated bar including gas dynamics and study the effect of two-dimensional spectroscopy data quality on robustness of the method. We added white noise and a Gaussian random field to the data and measured the corresponding errors in Ω P . We found that a signal to noise ratio in surface density ∼5 introduces errors of ∼20% for the Gaussian noise, while for the white noise the corresponding errors reach ∼50%. At the same time, the velocity field is less sensitive to contamination. On the basis of the performed study, we applied the method to the NGC 3367 spiral galaxy using Hα Fabry-Perot interferometry data. We found Ω P = 43 ± 6 km s -1 kpc -1 for this galaxy.

  6. Patterns of motor recruitment can be determined using surface EMG.

    Science.gov (United States)

    Wakeling, James M

    2009-04-01

    Previous studies have reported how different populations of motor units (MUs) can be recruited during dynamic and locomotor tasks. It was hypothesised that the higher-threshold units would contribute higher-frequency components to the sEMG spectra due to their faster conduction velocities, and thus recruitment patterns that increase the proportion of high-threshold units active would lead to higher-frequency elements in the sEMG spectra. This idea was tested by using a model of varying recruitment coupled to a three-layer volume conductor model to generate a series of sEMG signals. The recruitment varied from (A) orderly recruitment where the lowest-threshold MUs were initially activated and higher-threshold MUs were sequentially recruited as the contraction progressed, (B) a recurrent inhibition model that started with orderly recruitment, but as the higher-threshold units were activated they inhibited the lower-threshold MUs (C) nine models with intermediate properties that were graded between these two extremes. The sEMG was processed using wavelet analysis and the spectral properties quantified by their mean frequency, and an angle theta that was determined from the principal components of the spectra. Recruitment strategies that resulted in a greater proportion of faster MUs being active had a significantly lower theta and higher mean frequency.

  7. Use of ecoacoustics to determine biodiversity patterns across ecological gradients.

    Science.gov (United States)

    Grant, Paul B C; Samways, Michael J

    2016-12-01

    The variety of local animal sounds characterizes a landscape. We used ecoacoustics to noninvasively assess the species richness of various biotopes typical of an ecofriendly forest plantation with diverse ecological gradients and both nonnative and indigenous vegetation. The reference area was an adjacent large World Heritage Site protected area (PA). All sites were in a global biodiversity hotspot. Our results showed how taxa segregated into various biotopes. We identified 65 singing species, including birds, frogs, crickets, and katydids. Large, natural, protected grassland sites in the PA had the highest mean acoustic diversity (14.1 species/site). Areas covered in nonnative timber or grass species were devoid of acoustic species. Sites grazed by native and domestic megaherbivores were fairly rich (5.1) in acoustic species but none were unique to this habitat type, where acoustic diversity was greater than in intensively managed grassland sites (0.04). Natural vegetation patches inside the plantation mosaic supported high mean acoustic diversity (indigenous forests 7.6, grasslands 8.0, wetlands 9.1), which increased as plant heterogeneity and patch size increased. Indigenous forest patches within the plantation mosaic contained a highly characteristic acoustic species assemblage, emphasizing their complementary contribution to local biodiversity. Overall, acoustic signals determined spatial biodiversity patterns and can be a useful tool for guiding conservation. © 2016 Society for Conservation Biology.

  8. JUNO. Determination of the neutrino mass hierarchy using reactor neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Wonsak, Bjoern [Hamburg University, Inst. Exp. Phys., Hamburg (Germany)

    2015-07-01

    The Jiangmen Underground Neutrino Observatory (JUNO) is a medium-baseline reactor neutrino experiment located in China. Its aim is to determine the neutrino mass hierarchy at more than 3 sigma significance after six years of data taking by using a 20kt liquid scintillator detector. To achieve this goal, an energy resolution of less than 3%/√(E) is necessary, creating strict requirements on the detector design and the liquid scintillator. Moreover, JUNO will be the only experiment in the near future able to measure the solar mixing parameters with a precision of better than 1%. This is at the same level as our current knowledge on flavour mixing in the quark sector, marking an important milestone of neutrino physics. In addition, supernova neutrinos, geo-neutrinos, sterile neutrinos as well as solar and atmospheric neutrinos can be studied. JUNO was approved in 2013 and the construction of the underground facility started early this year. In this talk the status of the experiment and its prospects is discussed.

  9. Determinism and mass-media portrayals of genetics.

    Science.gov (United States)

    Condit, C M; Ofulue, N; Sheedy, K M

    1998-01-01

    Scholars have expressed concern that the introduction of substantial coverage of "medical genetics" in the mass media during the past 2 decades represents an increase in biological determinism in public discourse. To test this contention, we analyzed the contents of a randomly selected, structured sample of American public newspapers (n=250) and magazines (n=722) published during 1919-95. Three coders, using three measures, all with intercoder reliability >85%, were employed. Results indicate that the introduction of the discourse of medical genetics is correlated with both a statistically significant decrease in the degree to which articles attribute human characteristics to genetic causes (P<.001) and a statistically significant increase in the differentiation of attributions to genetic and other causes among various conditions or outcomes (P<. 016). There has been no statistically significant change in the relative proportions of physical phenomena attributed to genetic causes, but there has been a statistically significant decrease in the number of articles assigning genetic causes to mental (P<.002) and behavioral (P<.000) characteristics. These results suggest that the current discourse of medical genetics is not accurately described as more biologically deterministic than its antecedents. PMID:9529342

  10. Diagnostic performance and color overlay pattern in shear wave elastography (SWE) for palpable breast mass.

    Science.gov (United States)

    Park, Jiyoon; Woo, Ok Hee; Shin, Hye Seon; Cho, Kyu Ran; Seo, Bo Kyoung; Kang, Eun Young

    2015-10-01

    The purpose of this study is to evaluate the diagnostic performance of SWE in palpable breast mass and to compare with color overlay pattern in SWE with conventional US and quantitative SWE for assessing palpable breast mass. SWE and conventional breast US were performed in 133 women with 156 palpable breast lesions (81 benign, 75 malignant) between August 2013 to June 2014. Either pathology or periodic imaging surveillance more than 2 years was a reference standard. Existence of previous image was blinded to performing radiologists. US BI-RADS final assessment, qualitative and quantitative SWE measurements were evaluated. Diagnostic performances of grayscale US, SWE and US combined to SWE were calculated and compared. Correlation between pattern classification and quantitative SWE was evaluated. Both color overlay pattern and quantitative SWE improved the specificity of conventional US, from 81.48% to 96.30% (p=0.0005), without improvement in sensitivity. Color overlay pattern was significantly related to all quantitative SWE parameters and malignancy rate (pbreast mass, conventional US combine to SWE improves specificity and reduces the number of biopsies that ultimately yield a benign result. Color overlay pattern classification is more quick and easy and may represent quantitative SWE measurements with similar diagnostic performances. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Offending, Adjudication, and Outcome Patterns of Solo Male, Solo Female, and Partnered Mass Murderers.

    Science.gov (United States)

    Gurian, Elizabeth A

    2018-05-01

    Research on mass murder is limited due to differences in definitions (particularly with respect to victim count), as well as categorizations based on motive. These limitations restrict our understanding of the offending, adjudication, and outcome patterns of these offenders and can obscure potential underlying similarities to comparable types of offenders (e.g., lone actors or terrorists). To address some of these limitations, this research study, which includes an international sample of 434 cases (455 total offenders), uses descriptive and empirical analyses of solo male, solo female, and partnered mass murderers (teams of two or more) to explore offending, adjudication, and outcome patterns among these different types offenders. While the results from this research study support much previous mass murder research, the findings also emphasize the importance of large international sample sizes, objective categorizations, and the use of empirically based analyses to further advance our understanding of these offenders.

  12. Patterns of cross-continental variation in tree seed mass in the Canadian Boreal Forest.

    Directory of Open Access Journals (Sweden)

    Jushan Liu

    Full Text Available Seed mass is an adaptive trait affecting species distribution, population dynamics and community structure. In widely distributed species, variation in seed mass may reflect both genetic adaptation to local environments and adaptive phenotypic plasticity. Acknowledging the difficulty in separating these two aspects, we examined the causal relationships determining seed mass variation to better understand adaptability and/or plasticity of selected tree species to spatial/climatic variation. A total of 504, 481 and 454 seed collections of black spruce (Picea mariana (Mill. B.S.P., white spruce (Picea glauca (Moench Voss and jack pine (Pinus banksiana Lamb across the Canadian Boreal Forest, respectively, were selected. Correlation analyses were used to determine how seed mass vary with latitude, longitude, and altitude. Structural Equation Modeling was used to examine how geographic and climatic variables influence seed mass. Climatic factors explained a large portion of the variation in seed mass (34, 14 and 29%, for black spruce, white spruce and jack pine, respectively, indicating species-specific adaptation to long term climate conditions. Higher annual mean temperature and winter precipitation caused greater seed mass in black spruce, but annual precipitation was the controlling factor for white spruce. The combination of factors such as growing season temperature and evapotranspiration, temperature seasonality and annual precipitation together determined seed mass of jack pine. Overall, sites with higher winter temperatures were correlated with larger seeds. Thus, long-term climatic conditions, at least in part, determined spatial variation in seed mass. Black spruce and Jack pine, species with relatively more specific habitat requirements and less plasticity, had more variation in seed mass explained by climate than did the more plastic species white spruce. As traits such as seed mass are related to seedling growth and survival, they

  13. Pattern and determinants of birth weight in Oman.

    Science.gov (United States)

    Islam, M M; ElSayed, M K

    2015-12-01

    The aim of this study was to analyse the pattern of birth weight (BW) and identify the factors affecting BW and the risk factors of low birth weight (LBW) in Oman. The data for the study came from the 2000 Oman National Health Survey conducted by the Ministry of Health. The survey covered a nationally representative sample of 2037 ever married Omani women of reproductive age. Data on birth weight were gathered from health cards of the infants born within five years before the survey date. The study considered 977 singleton live births for whom data on birth weights were available. LBW was defined as BW less than 2500 g. Descriptive statistics, analysis of variance, multivariate linear regression and logistic regression models were used for data analysis. The mean BW was found to be 3.09 (SD 0.51) kg. BW was found to be significantly lower among the infants with the following characteristics: born in Ad-Dhakhliyah region, born in rural areas, and whose mothers had low economic status, low parity (0-2), and late initiation of antenatal care (ANC) visit. The incidence of LBW was found to be 9% in Oman in 2000. Mother's education, economic status, region of residence, late initiation of first ANC visit and experience of pregnancy complications appeared as the significant determinants of LBW in Oman. In contrast to most other studies, this study demonstrates that mothers with an advanced level of education (secondary and above) are more likely to have infants with LBW in Oman. The study findings highlight the need of intervention for specific groups of women with higher risk of adverse BW outcomes. Copyright © 2015 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  14. Simultaneous determination of mass and thermal accommodation coefficients from temporal evolution of an evaporating water microdroplet

    International Nuclear Information System (INIS)

    Zientara, M; Jakubczyk, D; Derkachov, G; Kolwas, K; Kolwas, M

    2005-01-01

    Scattering of coherent light by an evaporating droplet of pure water several micrometres in size was investigated. The droplet was levitated in an electrodynamic trap placed in a small climatic chamber. The evolution of the droplet radius and the evolution dynamics were investigated by means of analysing the scattering patterns with the aid of Mie theory. A numerical model of droplet evolution, incorporating the kinetic effects near the droplet surface, was constructed. Application of this model to the experimental data allowed us to determine the mass and thermal accommodation coefficients to be α C = 0.12 ± 0.02 and α T = 0.65 ± 0.09, respectively. This model enabled us to determine with high precision the temperature evolution of the droplet and the relative humidity in the droplet vicinity

  15. Ranking of factors determining potassium mass balance in bicarbonate haemodialysis.

    Science.gov (United States)

    Basile, Carlo; Libutti, Pasquale; Lisi, Piero; Teutonico, Annalisa; Vernaglione, Luigi; Casucci, Francesco; Lomonte, Carlo

    2015-03-01

    One of the most important pathogenetic factors involved in the onset of intradialysis arrhytmias is the alteration in electrolyte concentration, particularly potassium (K(+)). Two studies were performed: Study A was designed to investigate above all the isolated effect of the factor time t on intradialysis K(+) mass balance (K(+)MB): 11 stable prevalent Caucasian anuric patients underwent one standard (∼4 h) and one long-hour (∼8 h) bicarbonate haemodialysis (HD) session. The latter were pair-matched as far as the dialysate and blood volume processed (90 L) and volume of ultrafiltration are concerned. Study B was designed to identify and rank the other factors determining intradialysis K(+)MB: 63 stable prevalent Caucasian anuric patients underwent one 4-h standard bicarbonate HD session. Dialysate K(+) concentration was 2.0 mmol/L in both studies. Blood samples were obtained from the inlet blood tubing immediately before the onset of dialysis and at t60, t120, t180 min and at end of the 4- and 8-h sessions for the measurement of plasma K(+), blood bicarbonates and blood pH. Additional blood samples were obtained at t360 min for the 8 h sessions. Direct dialysate quantification was utilized for K(+)MBs. Direct potentiometry with an ion-selective electrode was used for K(+) measurements. Study A: mean K(+)MBs were significantly higher in the 8-h sessions (4 h: -88.4 ± 23.2 SD mmol versus 8 h: -101.9 ± 32.2 mmol; P = 0.02). Bivariate linear regression analyses showed that only mean plasma K(+), area under the curve (AUC) of the hourly inlet dialyser diffusion concentration gradient of K(+) (hcgAUCK(+)) and AUC of blood bicarbonates and mean blood bicarbonates were significantly related to K(+)MB in both 4- and 8-h sessions. A multiple linear regression output with K(+)MB as dependent variable showed that only mean plasma K(+), hcgAUCK(+) and duration of HD sessions per se remained statistically significant. Study B: mean K(+)MBs were -86.7 ± 22.6 mmol

  16. Socio-demographic and lifestyle determinants of dietary patterns in French-speaking Switzerland, 2009-2012.

    Science.gov (United States)

    Marques-Vidal, Pedro; Waeber, Gérard; Vollenweider, Peter; Guessous, Idris

    2018-01-12

    Food intake is a complex behaviour which can be assessed using dietary patterns. Our aim was to characterize dietary patterns and associated factors in French-speaking Switzerland. Cross-sectional study conducted between 2009 and 2012 in the city of Lausanne, Switzerland, including 4372 participants (54% women, 57.3 ± 10.3 years). Food consumption was assessed using a validated food frequency questionnaire. Dietary patterns were assessed by principal components analysis. Three patterns were identified: "Meat & fries"; "Fruits & Vegetables" and "Fatty & sugary". The "Meat & fries" pattern showed the strongest correlations with total and animal protein and cholesterol carbohydrates, dietary fibre and calcium. The "Fruits & Vegetables" pattern showed the strongest correlations with dietary fibre, carotene and vitamin D. The "Fatty & sugary" pattern showed the strongest correlations with total energy and saturated fat. On multivariate analysis, male gender, low educational level and sedentary status were positively associated with the "Meat & fries" and the "Fatty & sugary" patterns, and negatively associated with the "Fruits & Vegetables" pattern. Increasing age was inversely associated with the "Meat & fries" pattern; smoking status was inversely associated with the "Fruits & Vegetables" pattern. Being born in Portugal or Spain was positively associated with the "Meat & fries" and the "Fruits & Vegetables" patterns. Increasing body mass index was positively associated with the "Meat & fries" pattern and inversely associated with the "Fatty & sugary" pattern. Three dietary patterns, one healthy and two unhealthy, were identified in the Swiss population. Several associated modifiable behaviours were identified; the information on socio- demographic determinants allows targeting of the most vulnerable groups in the context of public health interventions.

  17. Precise determination of W anfd Z masses in UA2

    International Nuclear Information System (INIS)

    Lefebvre, M.

    1990-01-01

    The UA2 experiment has collected large samples of W and Z events during the 1988 and 1989 runs at the CERN antipp Collider at √s = 630 GeV. These samples have been used to perform precise measurements of the masses of the W and Z bosons. After a careful analysis of systematic errors, an improved result is obtained for the mass ratio M W /M Z . This provides a new value for the weak mixing parameter sin 2 θ W . Furthermore, it can be combined with recent measurements of the Z mass from e + e - colliders to give an absolute measurement of the W mass, leading to the result m W = 80.49 ± 0.43(stat) ± 0.24(syst) GeV

  18. A realistic pattern of fermion masses from a five-dimensional SO(10) model

    International Nuclear Information System (INIS)

    Feruglio, Ferruccio; Patel, Ketan M.; Vicino, Denise

    2015-01-01

    We provide a unified description of fermion masses and mixing angles in the framework of a supersymmetric grand unified SO(10) model with anarchic Yukawa couplings of order unity. The space-time is five dimensional and the extra flat spatial dimension is compactified on the orbifold S 1 /(Z 2 ×Z 2 ′ ), leading to Pati-Salam gauge symmetry on the boundary where Yukawa interactions are localised. The gauge symmetry breaking is completed by means of a rather economic scalar sector, avoiding the doublet-triplet splitting problem. The matter fields live in the bulk and their massless modes get exponential profiles, which naturally explain the mass hierarchy of the different fermion generations. Quarks and leptons properties are naturally reproduced by a mechanism, first proposed by Kitano and Li, that lifts the SO(10) degeneracy of bulk masses in terms of a single parameter. The model provides a realistic pattern of fermion masses and mixing angles for large values of tan β. It favours normally ordered neutrino mass spectrum with the lightest neutrino mass below 0.01 eV and no preference for leptonic CP violating phases. The right handed neutrino mass spectrum is very hierarchical and does not allow for thermal leptogenesis. We analyse several variants of the basic framework and find that the results concerning the fermion spectrum are remarkably stable.

  19. Implicit Priors in Galaxy Cluster Mass and Scaling Relation Determinations

    Science.gov (United States)

    Mantz, A.; Allen, S. W.

    2011-01-01

    Deriving the total masses of galaxy clusters from observations of the intracluster medium (ICM) generally requires some prior information, in addition to the assumptions of hydrostatic equilibrium and spherical symmetry. Often, this information takes the form of particular parametrized functions used to describe the cluster gas density and temperature profiles. In this paper, we investigate the implicit priors on hydrostatic masses that result from this fully parametric approach, and the implications of such priors for scaling relations formed from those masses. We show that the application of such fully parametric models of the ICM naturally imposes a prior on the slopes of the derived scaling relations, favoring the self-similar model, and argue that this prior may be influential in practice. In contrast, this bias does not exist for techniques which adopt an explicit prior on the form of the mass profile but describe the ICM non-parametrically. Constraints on the slope of the cluster mass-temperature relation in the literature show a separation based the approach employed, with the results from fully parametric ICM modeling clustering nearer the self-similar value. Given that a primary goal of scaling relation analyses is to test the self-similar model, the application of methods subject to strong, implicit priors should be avoided. Alternative methods and best practices are discussed.

  20. Density-body mass relationships: Inconsistent intercontinental patterns among termite feeding-groups

    Science.gov (United States)

    Dahlsjö, Cecilia A. L.; Parr, Catherine L.; Malhi, Yadvinder; Meir, Patrick; Rahman, Homathevi; Eggleton, Paul

    2015-02-01

    Allometric relationships are useful for estimating and understanding resource distribution in assemblages with species of different masses. Damuth's law states that body mass scales with population density as M-0.75, where M is body mass and -0.75 is the slope. In this study we used Damuth's law (M-0.75) as a null hypothesis to examine the relationship between body mass and population density for termite feeding-groups in three different countries and regions (Cameroon, West Africa; Peru South America; and Malaysia SE Asia). We found that none of the feeding-groups had a relationship where M-0.75 while the data suggested that population density-body mass relationships for true soil-feeding termites in Cameroon (M2.7) and wood-feeding termites in Peru (M1.5) were significantly different from the expected values given by Damuth's law. The dominance of large-bodied true soil-feeding termites in Cameroon and the absence of fungus-growing termites from Peru suggest that these allometric patterns are due to heterogeneities in termite biogeographical evolution. Additionally, as these feeding-groups have higher population density than expected by their body masses it may be suggested that they also have a higher energy throughput than expected. The results presented here may be used to gain further understanding of resource distribution among termite feeding-groups across regions and an insight into the importance of evolutionary history and biogeography on allometric patterns. Further understanding of population density-body mass relationships in termite feeding-groups may also improve understanding of the role these feeding-groups play in ecosystem processes in different regions.

  1. Determination of {sup 135}Cs by accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, C.M.; Charles, C.R.J. [Andre. E. Lalonde AMS Laboratory, University of Ottawa, 150 Louis Pasteur, Ottawa, ON K1N 6N5 (Canada); Department of Earth Sciences, University of Ottawa, 150 Louis Pasteur, Ottawa, ON K1N 6N5 (Canada); Zhao, X.-L.; Kieser, W.E. [Andre. E. Lalonde AMS Laboratory, University of Ottawa, 150 Louis Pasteur, Ottawa, ON K1N 6N5 (Canada); Department of Physics, University of Ottawa, 150 Louis Pasteur, Ottawa, ON K1N 6N5 (Canada); Cornett, R.J. [Andre. E. Lalonde AMS Laboratory, University of Ottawa, 150 Louis Pasteur, Ottawa, ON K1N 6N5 (Canada); Department of Earth Sciences, University of Ottawa, 150 Louis Pasteur, Ottawa, ON K1N 6N5 (Canada); Litherland, A.E. [IsoTrace Laboratory, University of Toronto, 60 St. George St., Toronto, ON M5S 1A7 (Canada)

    2015-10-15

    The ratio of anthropogenic {sup 135}Cs and {sup 137}Cs isotopes is characteristic of a uranium fission source. This research evaluates the technique of isotope dilution (yield tracing) for the purpose of quantifying {sup 135}Cs by accelerator mass spectrometry with on-line isobar separation. Interferences from Ba, Zn{sub 2}, and isotopes of equal mass to charge ratios were successfully suppressed. However, some sample crosstalk from source contamination remains. The transmission and di-fluoride ionization efficiencies of Cs isotopes were found to be 8 × 10{sup −3} and 1.7 × 10{sup −7} respectively. This quantification of {sup 135}Cs using yield tracing by accelerator mass spectrometry shows promise for future environmental sample analysis once the issues of sample crosstalk and low efficiency can be resolved.

  2. Direct gravimetric determination of aerosol mass concentration in central antarctica.

    Science.gov (United States)

    Annibaldi, Anna; Truzzi, Cristina; Illuminati, Silvia; Scarponi, Giuseppe

    2011-01-01

    In Antarctica, experimental difficulties due to extreme conditions have meant that aerosol mass has rarely been measured directly by gravimetry, and only in coastal areas where concentrations were in the range of 1-7 μg m(-3). The present work reports on a careful differential weighing methodology carried out for the first time on the plateau of central Antarctica (Dome C, East Antarctica). To solve problems of accurate aerosol mass measurements, a climatic room was used for conditioning and weighing filters. Measurements were carried out in long stages of several hours of readings with automatic recording of temperature/humidity and mass. This experimental scheme allowed us to sample from all the measurements (up to 2000) carried out before and after exposure, those which were recorded under the most stable humidity conditions and, even more importantly, as close to each other as possible. The automatic reading of the mass allowed us in any case to obtain hundreds of measurements from which to calculate average values with uncertainties sufficiently low to meet the requirements of the differential weighing procedure (±0.2 mg in filter weighing, between ±7% and ±16% both in aerosol mass and concentration measurements). The results show that the average summer aerosol mass concentration (aerodynamic size ≤10 μm) in central Antarctica is about 0.1 μg m(-3), i.e., about 1/10 of that of coastal Antarctic areas. The concentration increases by about 4-5 times at a site very close to the station.

  3. Determining neutrino mass from the cosmic microwave background alone.

    Science.gov (United States)

    Kaplinghat, Manoj; Knox, Lloyd; Song, Yong-Seon

    2003-12-12

    Distortions of cosmic microwave background temperature and polarization maps caused by gravitational lensing, observable with high angular resolution and high sensitivity, can be used to measure the neutrino mass. Assuming two massless species and one with mass m(nu), we forecast sigma(m(nu))=0.15 eV from the Planck satellite and sigma(m(nu))=0.04 eV from observations with twice the angular resolution and approximately 20 times the sensitivity. A detection is likely at this higher sensitivity since the observation of atmospheric neutrino oscillations requires Deltam(2)(nu) greater, similar (0.04 eV)(2).

  4. UP-HILIC-MS/MS to Determine the Action Pattern of Penicillium sp. Dextranase

    Science.gov (United States)

    Yi, Lin; Sun, Xue; Du, Kenze; Ouyang, Yilan; Wu, Chengling; Xu, Naiyu; Linhardt, Robert J.; Zhang, Zhenqing

    2015-07-01

    Investigation of the action pattern of enzymes acting on carbohydrates is challenging, as both the substrate and the digestion products are complex mixtures. Dextran and its enzyme-derived oligosaccharides are widely used for many industrial applications. In this work, a new method relying on ultra-performance hydrophilic interaction liquid chromatography quadrupole time-of-flight tandem mass spectrometry (UP-HILIC- Q/TOF-MS/MS) was developed to analyze a complex mixture of dextran oligosaccharide products to determine the action pattern of dextranase. No derivatization of oligosaccharides was required and the impact of the α- and β-configurations of the native oligosaccharides on the chromatographic separation was eliminated. The 1→6, 1→3, 1→4 backbone linkages and the branch linkages of these oligosaccharides were all distinguished from diagnostic ions in their MS/MS spectra, including fragments corresponding to 0,2A, 0,3A, 0,4A, B-H2O, 2,5A, and 3,5A. The sequences of the oligosaccharide products were similarly established. Thus, the complex oligosaccharide mixtures in dextran digestion products were profiled and identified using this method. The more enzyme-resistant structures in dextran were established using much less sample, labor, time, and uncertainty than in previous studies. This method provides an efficient, sensitive, and straightforward way to monitor the entire process of digestion, establish the action pattern of the dextranase from Penicillium sp., and to support the proper industrial application of dextranase.

  5. Incorporating Biological Mass Spectrometry into Undergraduate Teaching Labs, Part 2: Peptide Identification via Molecular Mass Determination

    Science.gov (United States)

    Arnquist, Isaac J.; Beussman, Douglas J.

    2009-01-01

    Mass spectrometry has become a routine analytical tool in the undergraduate curriculum in the form of GC-MS. While relatively few undergraduate programs have incorporated biological mass spectrometry into their programs, the importance of these techniques, as demonstrated by their recognition with the 2002 Nobel Prize, will hopefully lead to…

  6. Determining intervention thresholds that change output behavior patterns

    NARCIS (Netherlands)

    Walrave, B.

    2016-01-01

    This paper details a semi-automated method that can calculate intervention thresholds—that is, the minimum required intervention sizes, over a given time frame, that result in a desired change in a system’s output behavior pattern. The method exploits key differences in atomic behavior profiles that

  7. Patterns of Mass Mortality among Rocky Shore Invertebrates across 100 km of Northeastern Pacific Coastline.

    Directory of Open Access Journals (Sweden)

    Laura J Jurgens

    Full Text Available Mass mortalities in natural populations, particularly those that leave few survivors over large spatial areas, may cause long-term ecological perturbations. Yet mass mortalities may remain undocumented or poorly described due to challenges in responding rapidly to unforeseen events, scarcity of baseline data, and difficulties in quantifying rare or patchily distributed species, especially in remote or marine systems. Better chronicling the geographic pattern and intensity of mass mortalities is especially critical in the face of global changes predicted to alter regional disturbance regimes. Here, we couple replicated post-mortality surveys with preceding long-term surveys and historical data to describe a rapid and severe mass mortality of rocky shore invertebrates along the north-central California coast of the northeastern Pacific Ocean. In late August 2011, formerly abundant intertidal populations of the purple sea urchin (Strongylocentrotus purpuratus, a well-known ecosystem engineer, and the predatory six-armed sea star (Leptasterias sp. were functionally extirpated from ~100 km of coastline. Other invertebrates, including the gumboot chiton (Cryptochiton stelleri the ochre sea star (Pisaster ochraceus, and subtidal populations of purple sea urchins also exhibited elevated mortality. The pattern and extent of mortality suggest the potential for long-term population, community, and ecosystem consequences, recovery from which may depend on the different dispersal abilities of the affected species.

  8. Determination of SB2 masses and age: introduction of the mass ratio in the Bayesian analysis

    Science.gov (United States)

    Giarrusso, M.; Leone, F.; Tognelli, E.; Degl'Innocenti, S.; Prada Moroni, P. G.

    2018-04-01

    Stellar age assignment still represents a difficult task in Astrophysics. This unobservable fundamental parameter can be estimated only through indirect methods, as well as generally the mass. Bayesian analysis is a statistical approach largely used to derive stellar properties by taking into account the available information about the quantities we are looking for. In this paper we propose to apply the method to the double-lined spectroscopic binaries (SB2), for which the only available information about masses is the observed mass ratio of the two components. We validated the method on a synthetic sample of Pre-Main Sequence (PMS) SB2 systems showing the capability of the technique to recover the simulated age and masses. Then, we applied our procedure to the PMS eclipsing binaries Parenago 1802 and RX J0529.4+0041 A, whose masses of both components are known, by treating them as SB2 systems. The estimated masses are in agreement with those dynamically measured. We conclude that the method, if based on high resolution and high signal-to-noise spectroscopy, represents a robust way to infer the masses of the very numerous SB2 systems together with their age, allowing to date the hosting astrophysical environments.

  9. Determination of SB2 masses and age: introduction of the mass ratio in the Bayesian analysis

    Science.gov (United States)

    Giarrusso, M.; Leone, F.; Tognelli, E.; Degl'Innocenti, S.; Prada Moroni, P. G.

    2018-07-01

    Stellar age assignment still represents a difficult task in Astrophysics. This unobservable fundamental parameter can be estimated only through indirect methods, as well as generally the mass. Bayesian analysis is a statistical approach largely used to derive stellar properties by taking into account the available information about the quantities we are looking for. In this paper, we propose to apply the method to the double-lined spectroscopic binaries (SB2), for which the only available information about masses is the observed mass ratio of the two components. We validated the method on a synthetic sample of pre-main-sequence (PMS) SB2 systems showing the capability of the technique to recover the simulated age and masses. Then, we applied our procedure to the PMS eclipsing binaries Parenago 1802 and RX J0529.4+0041 A, whose masses of both components are known, by treating them as SB2 systems. The estimated masses are in agreement with those dynamically measured. We conclude that the method, if based on high resolution and high signal-to-noise spectroscopy, represents a robust way to infer the masses of the very numerous SB2 systems together with their age, allowing to date the hosting astrophysical environments.

  10. Mass spectrometry-based serum proteome pattern analysis in molecular diagnostics of early stage breast cancer

    Directory of Open Access Journals (Sweden)

    Stobiecki Maciej

    2009-07-01

    Full Text Available Abstract Background Mass spectrometric analysis of the blood proteome is an emerging method of clinical proteomics. The approach exploiting multi-protein/peptide sets (fingerprints detected by mass spectrometry that reflect overall features of a specimen's proteome, termed proteome pattern analysis, have been already shown in several studies to have applicability in cancer diagnostics. We aimed to identify serum proteome patterns specific for early stage breast cancer patients using MALDI-ToF mass spectrometry. Methods Blood samples were collected before the start of therapy in a group of 92 patients diagnosed at stages I and II of the disease, and in a group of age-matched healthy controls (104 women. Serum specimens were purified and the low-molecular-weight proteome fraction was examined using MALDI-ToF mass spectrometry after removal of albumin and other high-molecular-weight serum proteins. Protein ions registered in a mass range between 2,000 and 10,000 Da were analyzed using a new bioinformatic tool created in our group, which included modeling spectra as a sum of Gaussian bell-shaped curves. Results We have identified features of serum proteome patterns that were significantly different between blood samples of healthy individuals and early stage breast cancer patients. The classifier built of three spectral components that differentiated controls and cancer patients had 83% sensitivity and 85% specificity. Spectral components (i.e., protein ions that were the most frequent in such classifiers had approximate m/z values of 2303, 2866 and 3579 Da (a biomarker built from these three components showed 88% sensitivity and 78% specificity. Of note, we did not find a significant correlation between features of serum proteome patterns and established prognostic or predictive factors like tumor size, nodal involvement, histopathological grade, estrogen and progesterone receptor expression. In addition, we observed a significantly (p = 0

  11. Plutonium determination in urine by techniques of mass spectrometry

    International Nuclear Information System (INIS)

    Hernandez M, H.; Yllera de Ll, A.

    2013-10-01

    The objective of this study was to develop an analytic method for quantification and plutonium reappraisal in plane tables of alpha spectrometry be means of the mass spectrometry technique of high resolution with plasma source inductively coupled and desolvator Aridus (Aridus-Hr-Icp-Ms) and mass spectrometry with accelerator (AMS). The obtained results were, the recovery percentage of Pu in the plane table was of ∼ 90% and activity minimum detectable obtained with Aridus-Hr-Icp-Ms and AMS was of ∼ 3 and ∼ 0.4 f g of 239 Pu, respectively. Conclusion, the results demonstrate the aptitude of the Aridus-Hr-Icp-Ms and AMS techniques in the Pu reappraisal in plane tables with bigger speed and precision, improving the values notably of the activity minimum detectable that can be obtained with the alpha spectrometry (∼ 50 f g of 239 Pu). (author)

  12. Precise determination of 40Ti mass by measuring the 40Sc isospin analogue state

    International Nuclear Information System (INIS)

    Liu Weiping; Hellstroem, M.; Collatz, R.; Benlliure, J.; Cortina, G.D.; Farget, F.; Grawe, H.; Hu, Z.; Iwasa, N.; Pfuetzner, M.; Roeckl, E.; Chulkov, L.; Piechaczek, A.; Raabe, R.; Reusen, I.; Vancraeynest, G.; Woehr, A.

    2001-01-01

    The mass of 40 Ti has been determined by using the isobaric multiplet mass equation method. The experimental data of the 40 Ti β-decay were used to determine the level of the isospin analogue state of 40 Sc. The ground-state mass excess and the Q EC value for 40 Ti were determined to be -9060 +- 12 keV and 11466 +- 13 keV, respectively

  13. Identification of volatile and semivolatile compounds in chemical ionization GC-MS using a mass-to-structure (MTS) Search Engine with integral isotope pattern ranking.

    Science.gov (United States)

    Liao, Wenta; Draper, William M

    2013-02-21

    The mass-to-structure or MTS Search Engine is an Access 2010 database containing theoretical molecular mass information for 19,438 compounds assembled from common sources such as the Merck Index, pesticide and pharmaceutical compilations, and chemical catalogues. This database, which contains no experimental mass spectral data, was developed as an aid to identification of compounds in atmospheric pressure ionization (API)-LC-MS. This paper describes a powerful upgrade to this database, a fully integrated utility for filtering or ranking candidates based on isotope ratios and patterns. The new MTS Search Engine is applied here to the identification of volatile and semivolatile compounds including pesticides, nitrosoamines and other pollutants. Methane and isobutane chemical ionization (CI) GC-MS spectra were obtained from unit mass resolution mass spectrometers to determine MH(+) masses and isotope ratios. Isotopes were measured accurately with errors of Search Engine and details performance testing with over 50 model compounds.

  14. Determination of high molecular mass compounds from Amazonian plant's leaves

    International Nuclear Information System (INIS)

    Siqueira, Denilson Soares de; Pereira, Alberto dos Santos; Aquino Neto, Francisco Radler de; Simoneit, Bernd R.T.

    2003-01-01

    The fractions of dichloromethane extracts of leaves from andiroba (Carapa guianensis - Meliaceae), caapi (Banisteriopsis caapi - Malpighiaceae), cocoa (Theobroma cacao - Sterculiaceae), Brazil nut (Bertholletia excelsa - Lecytidaceae), cupuacu (Theobroma grandiflorum - Sterculiaceae), marupa (Simaruba amara - Simaroubaceae) and rubber tree (Hevea brasiliensis - Euphorbiaceae), were analyzed by HT-HRGC and HT-HRGC-MS. Esters of homologous series of fatty acids and long chain alcohols, phytol, amyrines and tocopherols were characterized. The characterization of the compounds was based mainly in mass spectra data and in addition by usual spectrometric data ( 1 H and 13 C NMR, IR). (author)

  15. Determining Central Black Hole Masses in Distant Active Galaxies

    DEFF Research Database (Denmark)

    Vestergaard, Marianne

    2002-01-01

    An empirical relationship, of particular interest for studies of high redshift active galactic nuclei (AGNs) and quasars, between the masses of their central black-holes and rest-frame ultraviolet (UV) parameters measured in single-epoch AGN spectra is presented. This relationship is calibrated...... black-hole demographics at high redshift as well as to statistically study the fundamental properties of AGNs. The broad line region size - luminosity relationship is key to the calibrations presented here. The fact that its intrinsic scatter is also the main source of uncertainty in the calibrations...

  16. Uranium analysis. Impurities determination by spark mass spectrometry

    International Nuclear Information System (INIS)

    Anon.

    Determination of impurities in uranium, suitable for atomic content greater than 10 -8 , particularly adapted for a low content. The method is quantitative for metallic impurities and qualitative for non metallic impurities [fr

  17. Zirconium analysis. Impurities determination by spark mass specrometry

    International Nuclear Information System (INIS)

    Anon.

    Determination of impurities in zirconium, suitable for atomic content greater than 10 -8 but particularly adapted for low contents. The method is quantitative only if a reference sample is available (metallic impurities) [fr

  18. Determination of gaseous compounds using online mass spectrometry

    International Nuclear Information System (INIS)

    Praun, S.

    1999-08-01

    The work is divided in three major parts and describes various measurements of gaseous compounds. The first part tasks the problem of transit traffic along the motorway from Kufstein, Northern Tyrol/Austria until Ala, Trentino/Italy. During three periods measurements of the immissions of many compounds were carried out simultaneously in Northern Tyrol, Southern Tyrol and Trentino. The influence of the ban of heavy lorry traffic during the weekend and during the night on the reduction of NO 2 could be demonstrated. Furthermore certain compounds (e.g. Benzene) were monitored online for the first time along the motorway at lowest concentrations using the mass spectrometer 'Airsense 500'. In the second part online measurements of exhaled human breath after the oral application of a medicine against bronchitis was performed. In that way beside clinical and pharmacological studies the effectiveness of this pharmacon could be proved. The last part of the present work shows adsorption- and desorption measurements on four different adsorbents. During this procedure seven different gases with an increasing number of carbon atoms were monitored online by the hyphenation of these adsorbents with the mass spectrometer 'Airsense 500'. Thereby, the various properties of the adsorbents in the interaction with the gases could be demonstrated. (author)

  19. Protein Glycation in Diabetes as Determined by Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Annunziata Lapolla

    2013-01-01

    Full Text Available Diabetes is a common endocrine disorder characterized by hyperglycemia leading to nonenzymatic glycation of proteins, responsible for chronic complications. The development of mass spectrometric techniques able to give highly specific and reliable results in proteome field is of wide interest for physicians, giving them new tools to monitor the disease progression and the possible complications related to diabetes, as well as the effectiveness of therapeutic treatments. This paper reports and discusses some of the data pertaining protein glycation in diabetic subjects obtained by matrix-assisted laser desorption ionization (MALDI mass spectrometry (MS. The preliminary studies carried out by in vitro protein glycation experiments show clear differences in molecular weight of glycated and unglycated proteins. Then, the attention was focused on plasma proteins human serum albumin (HSA and immunoglobulin G (IgG. Enzymatic degradation products of in vitro glycated HSA were studied in order to simulate the in vivo enzymatic digestion of glycated species by the immunological system leading to the highly reactive advanced glycation end-products (AGEs peptides. Further studies led to the evaluation of glycated Apo A-I and glycated haemoglobin levels. A different MALDI approach was employed for the identification of markers of disease in urine samples of healthy, diabetic, nephropathic, and diabetic-nephropathic subjects.

  20. Determination of the mass-ratio distribution, I: single-lined spectroscopic binary stars

    NARCIS (Netherlands)

    Hogeveen, S.J.

    1992-01-01

    For single-lined spectroscopic binary stars (sbi), the mass ratio q = Msec=Mprim is calculated from the mass function f(m), which is determined from observations. For statistical investigations of the mass-ratio distribution, the term sin^3 i, that remains in the cubic equation from which q is

  1. Identification of a dietary pattern prospectively associated with bone mass in Australian young adults.

    Science.gov (United States)

    van den Hooven, Edith H; Ambrosini, Gina L; Huang, Rae-Chi; Mountain, Jenny; Straker, Leon; Walsh, John P; Zhu, Kun; Oddy, Wendy H

    2015-11-01

    Relatively little is known about the relations between dietary patterns and bone health in adolescence, which is a period of substantial bone mass accrual. We derived dietary patterns that were hypothesized to be related to bone health on the basis of their protein, calcium, and potassium contents and investigated their prospective associations with bone mineral density (BMD), bone area, and bone mineral content (BMC) in a cohort of young adults. The study included 1024 young adults born to mothers who were participating in the Western Australian Pregnancy Cohort (Raine) Study. Dietary information was obtained from food-frequency questionnaires at 14 and 17 y of age. Dietary patterns were characterized according to protein, calcium, and potassium intakes with the use of reduced-rank regression. BMD, bone area, and BMC were estimated with the use of a total body dual-energy X-ray absorptiometry scan at 20 y of age. We identified 2 major dietary patterns. The first pattern was positively correlated with intakes of protein, calcium, and potassium and had high factor loadings for low-fat dairy products, whole grains, and vegetables. The second pattern was positively correlated with protein intake but negatively correlated with intakes of calcium and potassium and had high factor loadings for meat, poultry, fish, and eggs. After adjustment for anthropometric, sociodemographic, and lifestyle factors, a higher z score for the first pattern at 14 y of age was positively associated with BMD and BMC at 20 y of age [differences: 8.6 mg/cm(2) (95% CI: 3.0, 14.1 mg/cm(2)) and 21.9 g (95% CI: 6.5, 37.3 g), respectively, per SD increase in z score]. The z score for this same pattern at 17 y of age was not associated with bone outcomes at 20 y of age. The second pattern at 14 or 17 y of age was not associated with BMD, BMC, or bone area. A dietary pattern characterized by high intakes of protein, calcium, and potassium in midadolescence was associated with higher BMD and BMC at 20

  2. Reduction of determinate errors in mass bias-corrected isotope ratios measured using a multi-collector plasma mass spectrometer

    International Nuclear Information System (INIS)

    Doherty, W.

    2015-01-01

    A nebulizer-centric instrument response function model of the plasma mass spectrometer was combined with a signal drift model, and the result was used to identify the causes of the non-spectroscopic determinate errors remaining in mass bias-corrected Pb isotope ratios (Tl as internal standard) measured using a multi-collector plasma mass spectrometer. Model calculations, confirmed by measurement, show that the detectable time-dependent errors are a result of the combined effect of signal drift and differences in the coordinates of the Pb and Tl response function maxima (horizontal offset effect). If there are no horizontal offsets, then the mass bias-corrected isotope ratios are approximately constant in time. In the absence of signal drift, the response surface curvature and horizontal offset effects are responsible for proportional errors in the mass bias-corrected isotope ratios. The proportional errors will be different for different analyte isotope ratios and different at every instrument operating point. Consequently, mass bias coefficients calculated using different isotope ratios are not necessarily equal. The error analysis based on the combined model provides strong justification for recommending a three step correction procedure (mass bias correction, drift correction and a proportional error correction, in that order) for isotope ratio measurements using a multi-collector plasma mass spectrometer

  3. The changing pattern and determinants of declining consanguinity in Jordan during 1990-2012.

    Science.gov (United States)

    Islam, M Mazharul

    2018-03-01

    Consanguinity is a deep rooted cultural trait in Jordan. To examine the patterns and determinants of declining rates of consanguineous marriage in Jordan during 1990-2012 in the context of the changing pattern of socio-economic and demographic conditions. The data come from the 1990 and 2012 Jordan Population and Family Health Surveys (JPFHSs). A total of 6461 women in 1990 and 11,352 women in 2012 were successfully interviewed. Descriptive and multivariate statistical techniques were used for data analysis. Consanguinity was found to be widely practiced (35% in 2012) until recent times in Jordan. However, there has been a secular declining trend over the last few decades as the practice of consanguinity has declined from 56% in 1990 to 35% in 2012. Increasing age at marriage and female education, higher level of education of husbands, declining family size, increasing rate of urbanisation and female employment, exposure to mass media and higher economic status appeared as significant predictors of declining consanguinity in Jordan. The findings of this study support Goode's hypothesis of a decrease of consanguinity with modernisation. Although consanguinity is a deeply rooted cultural trend in Jordan, it is gradually losing ground due to modernisation and socio-demographic transition of the country.

  4. Physical Activity And Dietary Fat As Determinants Of Body Mass ...

    African Journals Online (AJOL)

    Overweight/obesity and related disease conditions will constitute a major threat to the economically productive adults and subsequently, will present a huge health-care burden on developing countries in the near future. Suspected determinants include physical activity and dietary fat. The main indicator of ...

  5. Glucose tolerance in obese pregnant women determines newborn fat mass

    DEFF Research Database (Denmark)

    Carlsen, Emma Malchau; Renault, Kristina Martha; Nørgaard, Kirsten

    2016-01-01

    INTRODUCTION: Offspring of obese women have both short- and long-term increased morbidities. We investigated the relationship between maternal 2-h plasma glucose level determined by oral glucose tolerance test, degree of obesity, gestational weight gain and total fat, abdominal fat, and fat-free ...

  6. Determination of the Image Complexity Feature in Pattern Recognition

    Directory of Open Access Journals (Sweden)

    Veacheslav L. Perju

    2003-11-01

    Full Text Available The new image complexity informative feature is proposed. The experimental estimation of the image complexity is carried out. There are elaborated two optical-electronic processors for image complexity calculation. The determination of the necessary number of the image's digitization elements depending on the image complexity was carried out. The accuracy of the image complexity feature calculation was made.

  7. Explaining individual variation in patterns of mass loss in breeding birds

    Directory of Open Access Journals (Sweden)

    Cuthill Innes C

    2006-05-01

    Full Text Available Abstract Background Studies of birds have a disproportionate representation in the literature on life-history evolution, because of the (apparent ease with which the costs and benefits can be quantified and manipulated. During reproduction, birds frequently show a highly conserved pattern of mass change and changes in mass loss during breeding have been widely considered to be a valid short-term measure of the costs of reproduction. Experimental manipulations of the breeding attempts of birds usually argue that the presence of a response shows that a cost of reproduction exists, but there is little consensus as to how the size of these costs can be measured. Results We model this mass loss by considering how a parent can maximise its lifetime reproductive success, using a theoretical framework that is particularly suited to modelling parental care in altricial birds. If lifetime reproductive success is taken to be the sum of a parent's current and future reproductive success, we show that the exact forms of these components will influence the optimal amount of mass a parent should lose. In particular, we demonstrate that the shape of the relationship between parental investment and chick survival will lead to differing degrees of investment between parents of different initial qualities: parents with initially high levels of energy reserves could conceivably invested a lesser, similar or greater amount of resources than parents with initially low reserves, and these initially 'heavy' parents could potentially end up being lighter than the initially 'lighter' individuals. Conclusion We argue that it is difficult to make predictions about the dependence of a parent's final mass on its initial mass, and therefore mass loss should only be used as a short-term measure of the costs of reproduction with caution. The model demonstrates that we require a better understanding of the relationship between mass loss and both current and future reproductive

  8. Determinants of practice patterns in pediatric UTI management.

    Science.gov (United States)

    Selekman, R E; Allen, I E; Copp, H L

    2016-10-01

    Urinary tract infection (UTI) affects 10% of girls and 3% of boys by age 16. Both the American Academy of Pediatrics and National Institute for Health and Clinical Excellence Guidelines recommend urine testing prior to initiation of antibiotic treatment and the use of local antibiograms to guide empiric antibiotic therapy. Urine culture results not only provide the opportunity to halt empiric therapy if there is no bacterial growth, but also allow for tailoring of broad-spectrum therapy. Additionally, the use of antiobiograms improves empiric antibiotic selection based on local resistance patterns. However, execution of guideline recommendations has proved challenging. Understanding barriers in implementation is critical to developing targeted interventions aimed to improve adherence to these guidelines. The present study sought to investigate practice patterns and factors that influence urine testing and antibiogram use in the setting of empiric antibiotic treatment of UTI in children to ultimately improve adherence to UTI management guidelines. A random, national sample of physicians caring for children was surveyed from the American Medical Association Masterfile. Participants were queried regarding practice type, length of time in practice, factors influencing urine testing, urine specimen collection method, and antibiogram utilization. Logistic regression was used to assess factors associated with use of urine testing, bagged specimens, and antibiograms. Of respondents who acknowledged contact by surveyors, 47% completed the survey (n = 366). Most respondents (84%) obtain urinalysis and culture prior to treatment for UTI. Physicians report they would more likely order testing if the specimen were easier to collect (46%) and if results were available immediately (48%) (Table). Urine collection by bag was more common in circumcised boys (>30%) compared with girls (20%) and uncircumcised boys (20%) (P = 0.02). The most common reasons for collection by bag

  9. Determination of the Relative Atomic Masses of Metals by Liberation of Molecular Hydrogen

    Science.gov (United States)

    Waghorne, W. Earle; Rous, Andrew J.

    2009-01-01

    Students determine the relative atomic masses of calcium, magnesium, and aluminum by reaction with hydrochloric acid and measurement of the volume of hydrogen gas liberated. The experiment demonstrates stoichiometry and illustrates clearly that mass of the reagent is not the determinant of the amounts in chemical reactions. The experiment is…

  10. Different localization patterns of anthocyanin species in the pericarp of black rice revealed by imaging mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Yukihiro Yoshimura

    Full Text Available Black rice (Oryza sativa L. Japonica contains high levels of anthocyanins in the pericarp and is considered an effective health-promoting food. Several studies have identified the molecular species of anthocyanins in black rice, but information about the localization of each anthocyanin species is limited because methodologies for investigating the localization such as determining specific antibodies to anthocyanin, have not yet been developed Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS is a suitable tool for investigating the localization of metabolites. In this study, we identified 7 species of anthocyanin monoglycosides and 2 species of anthocyanin diglycosides in crude extracts from black rice by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS analysis. We also analyzed black rice sections by MALDI-IMS and found 2 additional species of anthocyanin pentosides and revealed different localization patterns of anthocyanin species composed of different sugar moieties. Anthocyanin species composed of a pentose moiety (cyanidin-3-O-pentoside and petunidin-3-O-pentoside were localized in the entire pericarp, whereas anthocyanin species composed of a hexose moiety (cyanidin-3-O-hexoside and peonidin-3-O-hexoside were focally localized in the dorsal pericarp. These results indicate that anthocyanin species composed of different sugar moieties exhibit different localization patterns in the pericarp of black rice. This is the first detailed investigation into the localization of molecular species of anthocyanins by MALDI-IMS.

  11. Mass-spectrometric determination in individual coated HTR fuel particles

    International Nuclear Information System (INIS)

    Strigl, A.

    1976-11-01

    A method is described which allows the simultaneous determination of fission and reaction gases in individual coated particles at temperatures up to 2000 0 C. The particles are heated under high-vacuum in a micro resistance-furnace up to the desired temperature. After preselected times the particles are crushed by action of a pneumatic cylinder. The gases liberated are fed into a quadrupoleanalyzer where they are analyzed in a dynamic mode. A peak selector allows the simultaneous measurement of up to four gases. The method is used routinely for the determination of fission gases (Kr and Xe) and of carbon monoxide which is formed as a reaction gas from oxide fuel. Precision and accuracy are in the order of a few percent. Detection limits for routine measurements are about 10 -7 cm 3 (STP) for KR and Xe and 2 x 10 -5 cm 3 (STP) for CO but can be lowered by special techniques. (author)

  12. Circular migration patterns and determinants in Nairobi slum settlements

    Directory of Open Access Journals (Sweden)

    Donatien Beguy

    2010-09-01

    Full Text Available This paper measures migration flows and determinants in two slum settlements in Nairobi City between 2003 and 2007. The results confirm the high intensity of migration with a quarter of the total slum population and a third of those aged 15-30 being renewed annually. A circular migration system is at play whereby the majority of slum dwellers are short-term migrants spending on average less than 3 years in the area. Migration is more intense during early adulthood (20-24, and despite very similar determinants across gender, mobility is more intense among women compared to men. The increasing feminization of migration is likely to change the face of slum settlements, resulting in more balanced sex ratios, in line with city-wide trends in Nairobi over the past half century. The high population turnover is due to the insecurity of livelihoods, tenure, and poor basic amenities and social services in slum settlements.

  13. Determination of the System Mass and the Individual Masses of Pluto and Charon from New Horizons Radio Tracking

    Science.gov (United States)

    Hahn, M.; Paetzold, M.; Andert, T.; Bird, M. K.; Tyler, G. L.; Hinson, D. P.; Linscott, I.; Stern, A.; Weaver, H. A., Jr.; Young, L. A.; Ennico Smith, K.; Olkin, C.

    2016-12-01

    One objective of the New Horizons Radio Science Experiment REX is the direct determination of the system mass and the individual masses of Pluto and Charon. About four weeks of two-way radio tracking centered around the closest approach of New Horizons to the Pluto system were processed. Major problems during the processing were the changes in spacecraft attitude by thrusters which applied extra Δv to the spacecraft motion masking partially the continuously perturbed motion caused by the attracting forces of the Pluto system members. The times of the spacecraft thruster activity are known but the applied Δv magnitude needed to be specifically adjusted. No two-way tracking was available during the flyby day on 14th July but slots of the REX one-way uplink observations cover the most important time near closest approach, these are for example the Pluto and Charon Earth occultation entries and exits. The REX data during the flyby day allowed to extract the individual masses of Pluto and Charon from the system mass at high precision. The relative errors of the mass determinations are below 0.02% and 0.2%, respectively. The masses of the 4 small satellites in the Pluto system could not be resolved.

  14. Associations of Blood Pressure Dipping Patterns With Left Ventricular Mass and Left Ventricular Hypertrophy in Blacks: The Jackson Heart Study.

    Science.gov (United States)

    Abdalla, Marwah; Caughey, Melissa C; Tanner, Rikki M; Booth, John N; Diaz, Keith M; Anstey, D Edmund; Sims, Mario; Ravenell, Joseph; Muntner, Paul; Viera, Anthony J; Shimbo, Daichi

    2017-04-05

    Abnormal diurnal blood pressure (BP), including nondipping patterns, assessed using ambulatory BP monitoring, have been associated with increased cardiovascular risk among white and Asian adults. We examined the associations of BP dipping patterns (dipping, nondipping, and reverse dipping) with cardiovascular target organ damage (left ventricular mass index and left ventricular hypertrophy), among participants from the Jackson Heart Study, an exclusively black population-based cohort. Analyses included 1015 participants who completed ambulatory BP monitoring and had echocardiography data from the baseline visit. Participants were categorized based on the nighttime to daytime systolic BP ratio into 3 patterns: dipping pattern (≤0.90), nondipping pattern (>0.90 to ≤1.00), and reverse dipping pattern (>1.00). The prevalence of dipping, nondipping, and reverse dipping patterns was 33.6%, 48.2%, and 18.2%, respectively. In a fully adjusted model, which included antihypertensive medication use and clinic and daytime systolic BP, the mean differences in left ventricular mass index between reverse dipping pattern versus dipping pattern was 8.3±2.1 g/m 2 ( P pattern versus dipping pattern was -1.0±1.6 g/m 2 ( P =0.536). Compared with participants with a dipping pattern, the prevalence ratio for having left ventricular hypertrophy was 1.65 (95% CI, 1.05-2.58) and 0.96 (95% CI, 0.63-1.97) for those with a reverse dipping pattern and nondipping pattern, respectively. In this population-based study of blacks, a reverse dipping pattern was associated with increased left ventricular mass index and a higher prevalence of left ventricular hypertrophy. Identification of a reverse dipping pattern on ambulatory BP monitoring may help identify black at increased risk for cardiovascular target organ damage. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  15. Beyond the ridge pattern: multi-informative analysis of latent fingermarks by MALDI mass spectrometry.

    Science.gov (United States)

    Francese, S; Bradshaw, R; Ferguson, L S; Wolstenholme, R; Clench, M R; Bleay, S

    2013-08-07

    After over a century, fingerprints are still one of the most powerful means of biometric identification. The conventional forensic workflow for suspect identification consists of (i) recovering latent marks from crime scenes using the appropriate enhancement technique and (ii) obtaining an image of the mark to compare either against known suspect prints and/or to search in a Fingerprint Database. The suspect is identified through matching the ridge pattern and local characteristics of the ridge pattern (minutiae). However successful, there are a number of scenarios in which this process may fail; they include the recovery of partial, distorted or smudged marks, poor quality of the image resulting from inadequacy of the enhancement technique applied, extensive scarring/abrasion of the fingertips or absence of suspect's fingerprint records in the database. In all of these instances it would be very desirable to have a technology able to provide additional information from a fingermark exploiting its endogenous and exogenous chemical content. This opportunity could potentially provide new investigative leads, especially when the fingermark comparison and match process fails. We have demonstrated that Matrix Assisted Laser Desorption Ionisation Mass Spectrometry and Mass Spectrometry Imaging (MALDI MSI) can provide multiple images of the same fingermark in one analysis simultaneous with additional intelligence. Here, a review on the pioneering use and development of MALDI MSI for the analysis of latent fingermarks is presented along with the latest achievements on the forensic intelligence retrievable.

  16. Experimental determination of airplane mass and inertial characteristics

    Science.gov (United States)

    Wolowicz, C. H.; Yancey, R. B.

    1974-01-01

    Current practices are evaluated for experimentally determining airplane center of gravity, moments of inertia, and products of inertia. The techniques discussed are applicable to bodies other than airplanes. In pitching- and rolling-moment-of-inertia investigations with the airplane mounted on and pivoted about knife edges, the nonlinear spring moments that occur at large amplitudes of oscillation can be eliminated by using the proper spring configuration. The single-point suspension double-pendulum technique for obtaining yawing moments of inertia, products of inertia, and the inclination of the principal axis provides accurate results from yaw-mode oscillation data, provided that the sway-mode effects are minimized by proper suspension rig design. Rocking-mode effects in the data can be isolated.

  17. Model-independent X-ray Mass Determinations for Clusters of Galaxies

    Science.gov (United States)

    Nulsen, Paul

    2005-09-01

    We propose to use high quality X-ray data from the Chandra archive to determine the mass distributions of about 60 clusters of galaxies over the largest possible range of radii. By avoiding unwarranted assumptions, model-independent methods make best use of high quality data. We will employ two model-independent methods. That used by Nulsen & Boehringer (1995) to determine the mass of the Virgo Cluster and a new method, that will be developed as part of the project. The new method will fit a general mass model directly to the X-ray spectra, making best possible use of the fitting errors to constrain mass profiles.

  18. Patterns and determinants of mammography screening in Lebanese women.

    Science.gov (United States)

    Elias, Nadia; Bou-Orm, Ibrahim R; Adib, Salim M

    2017-03-01

    The associations of ever using and/or repeating a mammography test with psychosocial and socio-demographic factors were surveyed in 2014 among Lebanese women ≥ 40. A sample of 2400 women was selected across Lebanon. Variables with significant bivariate associations with various types of behaviors were entered in multivariate analysis. Of the total, 105 women (4·4%) had never heard of mammography as a tool for early breast cancer detection. Among the remaining 2295, 45% had ever used it, of whom 10% had obtained it for the first time within the 12 months preceding the survey. Repeaters were 67% of 926 women who had the time opportunity to do so (median lifetime frequency: 2). Older age, higher socio-economic status (SES) and living within the Greater Beirut (GB) area were significantly associated with ever-use. Within GB, psychosocial factors such as perceived susceptibility and benefits were most strongly associated with ever-use. Outside GB, socio-economic advantage seemed to mostly affect ever-use. Only 4% reported opposition from husbands to their mammography, and husband's support was significant for adherence to mammography guidelines mostly outside GB. Higher education emerged also as a significant socio-demographic determinant for ever-repeating in all regions. Perceived comfort of the previous test strongly affected the likelihood of repeating it. Providing mammography free-of-charge may alleviate some obstacles among women with socio-economic disadvantage. Stressing that good results one year do not make the cancer less likely or repeating the test less important, as well as improving the comfort of mammography testing could ensure test repeating.

  19. Relationship of Muscle Mass Determined by DEXA with Spirometric Results in Healthy Individuals.

    Science.gov (United States)

    Martín Holguera, Rafael; Turrión Nieves, Ana Isabel; Rodríguez Torres, Rosa; Alonso, María Concepción

    2017-07-01

    Muscle mass maybe a determining factor in the variability of spirometry results in individuals of the same sex and age who have similar anthropometric characteristics. The aim of this study was to determine the association between spirometric results from healthy individuals and their muscle mass assessed by dual energy X-ray absorptiometry (DEXA). A sample of 161 women and 144 men, all healthy non-smokers, was studied. Ages ranged from18 to77years. For each subject, spirometry results and total and regional lean mass values obtained by full body DEXA were recorded. A descriptive analysis of the variables and a regression analysis were performed to study the relationship between spirometric variables and lean body mass, correcting for age and body mass index (BMI). In both sexes all muscle mass variables correlated positively and significantly with spirometric variables, and to a greater extent in men. After partial adjustment of correlations by age and BMI, the factor which best explains the spirometric variables is the total lean body mass in men, and trunk lean body mass in women. In men, muscle mass in the lower extremities is most closely associated with spirometric results. In women, it is the muscle mass of the trunk. In both sexes muscle mass mainly affects FEV 1 . Copyright © 2016 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Determination of B and Li in nuclear materials by secondary-ion mass spectrometry

    International Nuclear Information System (INIS)

    Eby, R.E.; Christie, W.H.

    1981-01-01

    Secondary ion mass spectrometry (SIMS) was used to perform mass and isotopic analysis for B and Li in samples that are not readily amenable to more conventional mass spectrometric techniques (e.g., surface ionization, electron impact, etc.). In this paper three specific applications of SIMS analysis to nuclear materials are discussed: first, the quantitative determination of B and its isotopic composition in borosilicate glasses; second, the determination of the isotopic composition of B and Li in irradiated nuclear-grade aluminum oxide/boron carbide composite pellets, and, lastly, the quantitative and isotopic determination of B and Li in highly radioactive solutions of unknown composition

  1. Precise mass determination of single cell with cantilever-based microbiosensor system.

    Directory of Open Access Journals (Sweden)

    Bogdan Łabędź

    Full Text Available Having determined the mass of a single cell of brewer yeast Saccharomyces cerevisiae by means of a microcantilever-based biosensor Cantisens CSR-801 (Concentris, Basel, Switzerland, it was found that its dry mass is 47,65 ± 1,05 pg. Found to be crucial in this mass determination was the cell position along the length of the cantilever. Moreover, calculations including cells positions on the cantilever provide a threefold better degree of accuracy than those which assume uniform mass distribution. We have also examined the influence of storage time on the single cell mass. Our results show that after 6 months there is an increase in the average mass of a single yeast cell.

  2. Precise mass determination of single cell with cantilever-based microbiosensor system.

    Science.gov (United States)

    Łabędź, Bogdan; Wańczyk, Aleksandra; Rajfur, Zenon

    2017-01-01

    Having determined the mass of a single cell of brewer yeast Saccharomyces cerevisiae by means of a microcantilever-based biosensor Cantisens CSR-801 (Concentris, Basel, Switzerland), it was found that its dry mass is 47,65 ± 1,05 pg. Found to be crucial in this mass determination was the cell position along the length of the cantilever. Moreover, calculations including cells positions on the cantilever provide a threefold better degree of accuracy than those which assume uniform mass distribution. We have also examined the influence of storage time on the single cell mass. Our results show that after 6 months there is an increase in the average mass of a single yeast cell.

  3. Dietary patterns in Canadian men and women ages 25 and older: relationship to demographics, body mass index, and bone mineral density

    Directory of Open Access Journals (Sweden)

    Towheed Tanveer

    2010-01-01

    Full Text Available Abstract Background Previous research has shown that underlying dietary patterns are related to the risk of many different adverse health outcomes, but the relationship of these underlying patterns to skeletal fragility is not well understood. The objective of the study was to determine whether dietary patterns in men (ages 25-49, 50+ and women (pre-menopause, post-menopause are related to femoral neck bone mineral density (BMD independently of other lifestyle variables, and whether this relationship is mediated by body mass index. Methods We performed an analysis of 1928 men and 4611 women participants in the Canadian Multicentre Osteoporosis Study, a randomly selected population-based longitudinal cohort. We determined dietary patterns based on the self-administered food frequency questionnaires in year 2 of the study (1997-99. Our primary outcome was BMD as measured by dual x-ray absorptiometry in year 5 of the study (2000-02. Results We identified two underlying dietary patterns using factor analysis and then derived factor scores. The first factor (nutrient dense was most strongly associated with intake of fruits, vegetables, and whole grains. The second factor (energy dense was most strongly associated with intake of soft drinks, potato chips and French fries, certain meats (hamburger, hot dog, lunch meat, bacon, and sausage, and certain desserts (doughnuts, chocolate, ice cream. The energy dense factor was associated with higher body mass index independent of other demographic and lifestyle factors, and body mass index was a strong independent predictor of BMD. Surprisingly, we did not find a similar positive association between diet and BMD. In fact, when adjusted for body mass index, each standard deviation increase in the energy dense score was associated with a BMD decrease of 0.009 (95% CI: 0.002, 0.016 g/cm2 for men 50+ years old and 0.004 (95% CI: 0.000, 0.008 g/cm2 for postmenopausal women. In contrast, for men 25-49 years old

  4. A method for determination mass absorption coefficient of gamma rays by Compton scattering

    International Nuclear Information System (INIS)

    El Abd, A.

    2014-01-01

    A method was proposed for determination mass absorption coefficient of gamma rays for compounds, alloys and mixtures. It is based on simulating interaction processes of gamma rays with target elements having atomic numbers from Z=1 to Z=92 using the MCSHAPE software. Intensities of Compton scattered gamma rays at saturation thicknesses and at a scattering angle of 90° were calculated for incident gamma rays of different energies. The obtained results showed that the intensity of Compton scattered gamma rays at saturations and mass absorption coefficients can be described by mathematical formulas. These were used to determine mass absorption coefficients for compound, alloys and mixtures with the knowledge of their Compton scattered intensities. The method was tested by calculating mass absorption coefficients for some compounds, alloys and mixtures. There is a good agreement between obtained results and calculated ones using WinXom software. The advantages and limitations of the method were discussed. - Highlights: • Compton scattering of γ−rays was used for determining mass absorption coefficient. • Scattered intensities were determined by the MCSHAPE software. • Mass absorption coefficients were determined for some compounds, mixtures and alloys. • Mass absorption coefficients were calculated by Winxcom software. • Good agreements were found between determined and calculated results

  5. Special features of the isotope ratio determination using mass-spectrometer with induction-bound plasma

    International Nuclear Information System (INIS)

    Stepanov, A.I.; Ramendik, G.I.; Fatyushina, E.V.

    2000-01-01

    The origin of the errors arising upon measuring relative abundance of Nd, Yb, and Gd isotopes on a HP-4500 mass-spectrometer (USA) is studied. It is shown that the main origin of the error is the different sensitivity of the mass-spectrometer to ions of different masses. Optimal content of the elements in the solutions is established upon determination of their isotopic abundance [ru

  6. Mass determination of heavy nuclei by the (α, 8He) reaction

    International Nuclear Information System (INIS)

    Kato, S.; Kubono, S.; Tanaka, M.H.

    1991-07-01

    The atomic mass excesses of 86 Zr, 88 Mo, 181 Re, 193 Au, and 200 Pb were determined from the Q-value measurements of the (α, 8 He) reaction on 90 Zr, 92 Mo, 185 Re, 197 Au, and 204 Pb. Further, the mass excesses of 181 Os, 193 Hg, 204 Po, 208 Rn, 212 Ra, and 216 Th were deduced from the measured mass excesses and the known Q values of alpha and beta decays. (author)

  7. Precision electron-capture energy in {sup 202}Pb and its relevance for neutrino mass determination

    Energy Technology Data Exchange (ETDEWEB)

    Welker, A. [CERN, Geneva (Switzerland); Technische Universitaet Dresden, Dresden (Germany); Filianin, P. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Petersburg Nuclear Physics Institute, Gatchina (Russian Federation); Althubiti, N.A.S. [The University of Manchester, School of Physics and Astronomy, Manchester (United Kingdom); Atanasov, D.; Blaum, K.; Eliseev, S.; Kreim, S. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Cocolios, T.E. [The University of Manchester, School of Physics and Astronomy, Manchester (United Kingdom); KU Leuven, Instituut voor Kern- en Stralingsfysica, Leuven (Belgium); Herfurth, F.; Neidherr, D. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Lunney, D. [CSNSM-IN2P3-CNRS, Universite Paris-Sud, Orsay (France); Manea, V. [CERN, Geneva (Switzerland); Novikov, Yu. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Petersburg Nuclear Physics Institute, Gatchina (Russian Federation); Physics Faculty, St. Petersburg State University (Russian Federation); Rosenbusch, M.; Schweikhard, L.; Wienholtz, F. [Ernst-Moritz-Arndt-Universitaet, Institut fuer Physik, Greifswald (Germany); Wolf, R.N. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); The University of Sydney, ARC Centre of Excellence for Engineered Quantum Systems, Sydney (Australia); Zuber, K. [Technische Universitaet Dresden, Dresden (Germany)

    2017-07-15

    Within the framework of an extensive programme devoted to the search for alternative candidates for the neutrino mass determination, the atomic mass difference between {sup 202}Pb and {sup 202}Tl has been measured with the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN. The obtained value Q{sub EC} = 38.8(43) keV is three times more precise than the AME2012 value. While it will probably not lead to a replacement of {sup 163}Ho in modern experiments on the determination of the electron-neutrino mass, the electron capture in {sup 202}Pb would however allow a determination of the electron-neutrino mass on the few-eV level using a cryogenic micro-calorimeter. (orig.)

  8. A radioactive tracer dilution method to determine the mass of molten salt

    International Nuclear Information System (INIS)

    Lei Cao; Jarrell, Josh; Hardtmayer, D.E.; White, Susan; Herminghuysen, Kevin; Kauffman, Andrew; Sanders, Jeff; Li, Shelly

    2017-01-01

    A new technique for molten salt mass determination, termed radioactive tracer dilution, that uses 22 Na as a tracer was validated at bench scale. It has been a challenging problem to determine the mass of molten salt in irregularly shaped containers, where a highly radioactive, high-temperature molten salt was used to process nuclear spent/used fuel during electrochemical recycling (pyro-processing) or for coolant/fuel salt from molten salt reactors. A radioactive source with known activity is dissolved into the salt. After a complete mixture, a small amount of the salt is sampled and measured in terms of its mass and radioactivity. By finding the ratio of the mass to radioactivity, the unknown salt mass in the original container can be precisely determined. (author)

  9. Search for new candidates for the neutrino-oriented mass determination by electron-capture

    CERN Multimedia

    Herfurth, F; Boehm, C; Blaum, K; Beck, D

    2008-01-01

    This proposal is part of an extended program dedicated to the neutrino-mass determination in the electron-capture sector, which aims at ultra-precise mass measurements by Penning traps in combination with cryogenic micro-calorimetry for atomic de-excitation measurements. Here, precise mass measurements with ISOLTRAP are proposed for the orbital electron-capture nuclides $^{194}$Hg and $^{202}$Pb, as well as their daughters, with the goal to determine accurately their Q-values. These values are expected to be the smallest ones among a great variety of known electron-capture precursors. Therefore, these nuclides are strong candidates for an improved electron-neutrino mass determination. We ask for 8 shifts of on-line beam at ISOLDE for mass measurements of $^{194}$Hg, $^{194}$ Au, $^{202}$Pb, and $^{202}$Tl at ISOLTRAP.

  10. The Determination of Children's Knowledge of Global Lunar Patterns from Online Essays Using Text Mining Analysis

    Science.gov (United States)

    Cheon, Jongpil; Lee, Sangno; Smith, Walter; Song, Jaeki; Kim, Yongjin

    2013-01-01

    The purpose of this study was to use text mining analysis of early adolescents' online essays to determine their knowledge of global lunar patterns. Australian and American students in grades five to seven wrote about global lunar patterns they had discovered by sharing observations with each other via the Internet. These essays were analyzed for…

  11. Point-Mass Model for Nano-Patterning Using Dip-Pen Nanolithography (DPN

    Directory of Open Access Journals (Sweden)

    Seok-Won Kang

    2011-04-01

    Full Text Available Micro-cantilevers are frequently used as scanning probes and sensors in micro-electromechanical systems (MEMS. Usually micro-cantilever based sensors operate by detecting changes in cantilever vibration modes (e.g., bending or torsional vibration frequency or surface stresses - when a target analyte is adsorbed on the surface. The catalyst for chemical reactions (i.e., for a specific analyte can be deposited on micro-cantilevers by using Dip-Pen Nanolithography (DPN technique. In this study, we simulate the vibration mode in nano-patterning processes by using a Point-Mass Model (or Lumped Parameter Model. The results from the simulations are used to derive the stability of writing and reading mode for a particular driving frequency during the DPN process. In addition, we analyze the sensitivity of the tip-sample interaction forces in fluid (ink solution by utilizing the Derjaguin-Muller-Toporov (DMT contact theory.

  12. Determination of nuclear fuel burn-up using mass spectrometric techniques

    International Nuclear Information System (INIS)

    Saha, B.; Bagyalakshmi, R.; Periaswami, G.; Kavimandan, V.D.; Chitambar, S.A.; Jain, H.C.; Mathews, C.K.

    1977-01-01

    Determination of burn-up using a stable fission product monitor such as 148 Nd and heavy elements, determined by isotope dilution mass spectrometry gives the most accurate data. This report describes the work carried out to standardise the conditions for burn-up determination. Some typical results are given. (author)

  13. Water vapor mass balance method for determining air infiltration rates in houses

    Science.gov (United States)

    David R. DeWalle; Gordon M. Heisler

    1980-01-01

    A water vapor mass balance technique that includes the use of common humidity-control equipment can be used to determine average air infiltration rates in buildings. Only measurements of the humidity inside and outside the home, the mass of vapor exchanged by a humidifier/dehumidifier, and the volume of interior air space are needed. This method gives results that...

  14. Determination of the masses of electrical weak gauge bosons with L3

    CERN Document Server

    Rosenbleck, Christian

    2006-01-01

    This thesis presents the measurement of the masses of the carriers of the weak force in the Standard Model of Particle Physics, the gauge bosons W and Z. The masses are determined using the kinematics of the bosons' decay products. The data were collected by the L3 experiment at the Large Electron Positron Collider (LEP) at centre-of-mass energies, sqrt(s), between 183 GeV and 209 GeV in the years 1997 to 2000. The mass of the Z-boson, mZ, is already known very precisely: The L3 collaboration determined it to be mZ = 91.1898 +- 0.0031 GeV from a scan of the Z resonance. Therefore the main aim of this analysis is not the determination of the numerical value of mZ; instead the analysis is used to cross-check the measurement of the W boson mass since the methods are similar. Alternatively, the analysis can be used to measure the mean centre-of-mass energy at the L3 interaction point. The Z-boson mass is determined to be mZ = 91.272 +- 0.046 GeV. If interpreted as measurement of the centre-of-mass energy, this va...

  15. Molar mass determination of lignins by size-exclusion chromatography: towards standardisation of the method

    NARCIS (Netherlands)

    Baumberger, S.; Abaecherli, A.; Fasching, M.; Gellerstedt, G.; Gosselink, R.J.A.; Hortling, B.; Li, J.; Saake, B.; Jong, de E.

    2007-01-01

    The reactivity and physicochemical properties of lignins are partly governed by their molar mass distribution. The development of reliable standard methods for determination of the molar mass distribution is not only relevant for designing technical lignins for specific applications, but also for

  16. Quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry

    International Nuclear Information System (INIS)

    Ure, A.M.; Bacon, J.R.

    1978-01-01

    Experimental details are given of the quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry. The effects of interfering species, and corrections that can be applied, are discussed. (U.K.)

  17. Determination of trimethyllead reference material using high performance liquid chromatography-inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lu Hai; Wei Chao; Wang Jun; Chao Jingbo; Zhou Tao; Chen Dazhou

    2005-01-01

    A high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) was combined, and the chromatography conditions were optimized. The stability and homogeneity of a trimethyllead reference material were determined using this method. (authors)

  18. Correlation of acidic and basic carrier ampholyte and immobilized pH gradient two-dimensional gel electrophoresis patterns based on mass spectrometric protein identification

    DEFF Research Database (Denmark)

    Nawrocki, A; Larsen, Martin Røssel; Podtelejnikov, A V

    1998-01-01

    Separation of proteins on either carrier ampholyte-based or immobilized pH gradient-based two-dimensional (2-D) gels gives rise to electrophoretic patterns that are difficult to compare visually. In this paper we have used matrix-assisted laser desorption/ionization mass spectrometry (MALDI......-MS) to determine the identities of 335 protein spots in these two 2-D gel systems, including a substantial number of basic proteins which had never been identified before. Proteins that were identified in both gel systems allowed us to cross-reference the gel patterns. Vector analysis of these cross...

  19. Parallel patterns determination in solving cyclic flow shop problem with setups

    Directory of Open Access Journals (Sweden)

    Bożejko Wojciech

    2017-06-01

    Full Text Available The subject of this work is the new idea of blocks for the cyclic flow shop problem with setup times, using multiple patterns with different sizes determined for each machine constituting optimal schedule of cities for the traveling salesman problem (TSP. We propose to take advantage of the Intel Xeon Phi parallel computing environment during so-called ’blocks’ determination basing on patterns, in effect significantly improving the quality of obtained results.

  20. Using gravimetric measurement for determination of the mass fraction PM10

    Directory of Open Access Journals (Sweden)

    Nicolae Chirilă

    2011-12-01

    Full Text Available In this paper, we tried to determinate the air pollution level with mass fraction PM10 from Targu Mures area. For this purpose, determinations were made in University Petru Maior’s laboratory, using ADR 1200 S device and in Targu Mures Environmental Department’s laboratory. The results that we obtained show a low level of air pollution with mass fraction PM10 in Targu Mures area.

  1. Molecular effects in the neutrino mass determination from beta-decay of the tritium molecule

    International Nuclear Information System (INIS)

    Fackler, O.; Jeziorski, B.; Kolos, W.; Szalewicz, K.; Monkhorst, H.J.; Mugge, M.

    1986-03-01

    Molecular final state energies and transition probabilities have been computed for beta-decay of the tritium molecule. The results are of sufficient accuracy to make a determination of the electron neutrino rest mass with an error not exceeding a few tenths of an electron volt. Effects of approximate models of tritium beta-decay on the neutrino mass determination are discussed. 14 refs., 3 figs., 1 tab

  2. Evaluation difference between mass of received cargo and mass of handed over the cargo in the determination of the masses by draft survey

    Directory of Open Access Journals (Sweden)

    Yakuta I. V.

    2016-12-01

    Full Text Available The paper provides the analysis of problems associated with the evaluation of difference between the mass of received and handed over cargo in determining the masses by draft survey and due to the difference in the measurement conditions at the loading and unloading ports (due to the change errors in various stages of the measurement procedures. The errors that may arise in determining the mass of the cargo due to roughness when measuring draft, due to using the inclinometer to determine the draft from one of boards, due to instrumental errors in the determination of the density of seawater, due to other possible errors have been investigated and evaluated. To estimate the errors of draft due to heaving and errors of inclinometer some formula are to be applied, their derivation has been done in this paper. It has been recommended to use the traditional formula of high-speed drawdown with the replacement of vessel speed on current rate to calculate the error of precipitation arising from the drawdowns ship on a current. The value per unit displacement draft from loading scale has been used to evaluate the error of the displacement appearing in the presence of draft errors. As a result two similar criteria (rigorous and statistical of allowable discrepancies calculated by draft survey mass of cargo in the port of loading and port of discharge have been substantiated. These criteria require the calculation and accumulation in a table of all the errors and calculate the total error of displacement. Criteria will allow the consignee and the carrier come to a reasonable and agreed decision about the significance of differences of the masses taking into account the indifference of conditions and measuring instruments.

  3. The mass angular scattering power method for determining the kinetic energies of clinical electron beams

    International Nuclear Information System (INIS)

    Blais, N.; Podgorsak, E.B.

    1992-01-01

    A method for determining the kinetic energy of clinical electron beams is described, based on the measurement in air of the spatial spread of a pencil electron beam which is produced from the broad clinical electron beam. As predicted by the Fermi-Eyges theory, the dose distribution measured in air on a plane, perpendicular to the incident direction of the initial pencil electron beam, is Gaussian. The square of its spatial spread is related to the mass angular scattering power which in turn is related to the kinetic energy of the electron beam. The measured spatial spread may thus be used to determine the mass angular scattering power, which is then used to determine the kinetic energy of the electron beam from the known relationship between mass angular scattering power and kinetic energy. Energies obtained with the mass angular scattering power method agree with those obtained with the electron range method. (author)

  4. Comparison of STIM and particle backscattering spectrometry mass determination for quantitative microanalysis of cultured cells

    International Nuclear Information System (INIS)

    Deves, G.; Ortega, R.

    2001-01-01

    In biological sample microanalysis, a mass-normalisation method is commonly used as a quantitative index of elemental concentrations determined by particle-induced X-ray emission (PIXE). The organic mass can either be determined using particle backscattering spectrometry (BS) or scanning transmission ion microscopy (STIM). However, the accuracy of quantitative microanalysis in samples such as cultured cells is affected by beam-induced loss of organic mass during analysis. The aim of this paper is to compare mass measurements determined by particle BS or by STIM. In order to calibrate STIM and BS analyses, we measured by both techniques the thickness of standard foils of polycarbonate (3 and 6 μm), Mylar[reg] (4 μm), Kapton[reg] (7.5 μm) and Nylon[reg] (15 μm), as well as biological samples of mono-layered cultured cells. Non-damaging STIM analysis of samples before PIXE irradiation is certainly one of the most accurate ways to determine the sample mass, however, this requires strong experimental handling. On the other hand, BS performed simultaneously to PIXE is the simplest method to determine the local mass in polymer foils, but appears less accurate in the case of cultured cells

  5. Gas chromatography–triple quadrupole mass spectrometry for the determination of atmospheric polychlorinated naphthalenes

    Energy Technology Data Exchange (ETDEWEB)

    Li, Fang [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Jin, Jing [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China); Sun, Xiaoli [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Wang, Xueli; Li, Yun; Shah, Syed Mazhar [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China); Chen, Jiping, E-mail: chenjp@dicp.ac.cn [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China)

    2014-09-15

    Highlights: • Atmospheric PCNs were detected by isotope-dilution GC–MS/MS. • The pollution levels of PCNs covering from mono- to octa-CNs were investigated comprehensively in air samples. • The dioxin-like toxicity and human exposure levels of PCNs in air samples were estimated. - Abstract: Atmospheric polychlorinated naphthalenes (PCNs) ranging from mono-CNs to octa-CNs were detected using isotope-dilution gas chromatography coupled with triple quadrupole mass spectrometry (GC–MS/MS). The developed instrumental method was successfully applied to the determination of PCNs in technical products. It was observed that there were significant differences in concentrations, homologue profiles, chlorinated contents and total toxic equivalents (∑TEQs) of PCNs for four Halowax products. Subsequently, the validation of the analytical method was evaluated for the determination of PCNs in air samples in terms of method detection limit (MDL), recovery and matrix effect. The results demonstrated that this method could provide satisfactory sensitivity and adequate selectivity with lower cost. It was conducted to comprehensively evaluate the levels, composition patterns, ∑TEQs, and daily intake exposure of PCNs in indoor and outdoor air samples. Concentrations and ∑TEQs of PCNs in air samples ranged 47.7–832.7 pg m{sup −3} and 1.31–5.99 fg m{sup −3}, respectively, and the predominant homologues were di- and tri-CNs in the gas phase. The results indicated that this analytical method was useful for the accurate and specific evaluation of dioxin-like toxicity and human exposure levels of PCNs in the atmosphere.

  6. Mayfly and fish species identification and sex determination in bleak (Alburnus alburnus) by MALDI-TOF mass spectrometry.

    Science.gov (United States)

    Maasz, G; Takács, P; Boda, P; Varbiro, G; Pirger, Z

    2017-12-01

    Besides food quality control of fish or cephalopods, the novel mass spectrometry (MS) approaches could be effective and beneficial methods for the investigation of biodiversity in ecological research. Our aims were to verify the applicability of MALDI-TOF MS in the rapid identification of closely related species, and to further develop it for sex determination in phenotypically similar fish focusing on the low mass range. For MALDI-TOF MS spectra analysis, ClinProTools software was applied, but our observed classification was also confirmed by Self Organizing Map. For verifying the wide applicability of the method, brains from invertebrate and vertebrate species were used in order to detect the species related markers from two mayflies and eight fish as well as sex-related markers within bleak. Seven Ephemera larvae and sixty-one fish species related markers were observed and nineteen sex-related markers were identified in bleak. Similar patterns were observed between the individuals within one species. In contrast, there were markedly diverse patterns between the different species and sexes visualized by SOMs. Two different Ephemera species and male or female fish were identified with 100% accuracy. The various fish species were classified into 8 species with a high level of accuracy (96.2%). Based on MS data, dendrogram was generated from different fish species by using ClinProTools software. This MS-based dendrogram shows relatively high correspondence with the phylogenetic relationships of both the studied species and orders. In summary, MALDI-TOF MS provides a cheap, reliable, sensitive and fast identification tool for researchers in the case of closely related species using mass spectra acquired in a low mass range to define specific molecular profiles. Moreover, we presented evidence for the first time for determination of sex within one fish species by using this method. We conclude that it is a powerful tool that can revolutionize ecological and

  7. Mass determination based on electron scattering in electron probe X-ray microanalysis of thin biological specimens

    International Nuclear Information System (INIS)

    Linders, P.W.J.

    1984-01-01

    This thesis describes the development of a method for mass determination of thin biological objects by quantitative electron microscopy. The practical realization of the mass determination consists of photographical recording with subsequent densitometry. (Auth.)

  8. Mass

    International Nuclear Information System (INIS)

    Quigg, Chris

    2007-01-01

    In the classical physics we inherited from Isaac Newton, mass does not arise, it simply is. The mass of a classical object is the sum of the masses of its parts. Albert Einstein showed that the mass of a body is a measure of its energy content, inviting us to consider the origins of mass. The protons we accelerate at Fermilab are prime examples of Einsteinian matter: nearly all of their mass arises from stored energy. Missing mass led to the discovery of the noble gases, and a new form of missing mass leads us to the notion of dark matter. Starting with a brief guided tour of the meanings of mass, the colloquium will explore the multiple origins of mass. We will see how far we have come toward understanding mass, and survey the issues that guide our research today.

  9. Ex vivo determination of chewing patterns using FBG and artificial neural networks

    Science.gov (United States)

    Karam, L. Z.; Pegorini, V.; Pitta, C. S. R.; Assmann, T. S.; Cardoso, R.; Kalinowski, H. J.; Silva, J. C. C.

    2014-05-01

    This paper reports the experimental procedures performed in a bovine head for the determination of chewing patterns during the mastication process. Mandible movements during the chewing have been simulated either by using two plasticine materials with different textures or without material. Fibre Bragg grating sensors were fixed in the jaw to monitor the biomechanical forces involved in the chewing process. The acquired signals from the sensors fed the input of an artificial neural network aiming at the classification of the measured chewing patterns for each material used in the experiment. The results obtained from the simulation of the chewing process presented different patterns for the different textures of plasticine, resulting on the determination of three chewing patterns with a classification error of 5%.

  10. Dietary patterns among girls aged 16–18 years old according to their body mass index and waist-to-hip ratio

    Directory of Open Access Journals (Sweden)

    Agnieszka Dmitruk

    2018-03-01

    Full Text Available Aim: The study has been aimed at evaluating dietary patterns of girls aged 16–18 years old in groups identified according to measures such as their body mass index and waist-to-hip ratio. Material and methods: The study covered a total of 151 girls aged 16–18 years old from selected higher secondary schools in Biała Podlaska, Poland. Based on height, weight, waist and hip circumference measurements, body mass index was calculated for each of the participants of the study, allowing to identify two groups: group 1 with normal index and group 2 with overweight or obesity. Also, to determine the type of obesity in the overweight and obese respondents, their waist-to-hip ratio was calculated, identifying the subgroup of girls with abdominal obesity. The respondents’ dietary patterns were identified with the use of a diagnostic survey. The statistical significance of the differences between the participants with normal body mass index and the overweight and obese respondents (including those with abdominal obesity was tested with the chi-square test. Results: Numerous nutritional mistakes/unhealthy dietary patterns were identified in the studied group, largely involving the overweight and obese girls, including those with abdominal obesity. The respondents whose body mass index and waist-to-hip ratio were too high ate fewer meals per day, skipped breakfast more frequently, had their last meal of the day later than 8 p.m., reported less frequent fish and wholemeal bread intake, as opposed to more frequent fast food, sweets and sweetened beverages intake. Conclusion: The unhealthy dietary patterns found in the population of girls with high body mass index and abdominal obesity highlight the need for education in the scope of healthy nutrition aimed both at overweight/obese individuals and their families.

  11. Determination and correlation of mass transfer coefficients in a stirred cell

    International Nuclear Information System (INIS)

    Herranz, J.; Bloxom, S.R.; Keeler, J.B.; Roth, S.R.

    1975-01-01

    In the proposed Molten Salt Breeder Reactor flowsheet, a fraction of the rare earth fission products is removed from the fuel salt in mass transfer cells. To obtain design parameters for this extraction, the effect of cell size, blade diameter, phase volume, and agitation rate on the mass transfer for a high density ratio system (mercury/water) in nondispersing square cross section contactors was determined. Aqueous side mass transfer coefficients were measured by polarography over a wide range of operating conditions. Correlations for the experimental mass transfer coefficients as functions of the operating parameters are presented. Several techniques for measuring mercury-side mass transfer coefficients were evaluated and a new one is recommended

  12. A method for determination mass absorption coefficient of gamma rays by Compton scattering.

    Science.gov (United States)

    El Abd, A

    2014-12-01

    A method was proposed for determination mass absorption coefficient of gamma rays for compounds, alloys and mixtures. It is based on simulating interaction processes of gamma rays with target elements having atomic numbers from Z=1 to Z=92 using the MCSHAPE software. Intensities of Compton scattered gamma rays at saturation thicknesses and at a scattering angle of 90° were calculated for incident gamma rays of different energies. The obtained results showed that the intensity of Compton scattered gamma rays at saturations and mass absorption coefficients can be described by mathematical formulas. These were used to determine mass absorption coefficients for compound, alloys and mixtures with the knowledge of their Compton scattered intensities. The method was tested by calculating mass absorption coefficients for some compounds, alloys and mixtures. There is a good agreement between obtained results and calculated ones using WinXom software. The advantages and limitations of the method were discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Interlaboratory determinations of isotopically enriched metals by field desorption mass spectroscopy

    International Nuclear Information System (INIS)

    Bahr, U.; Schulten, H.R.; Achenbach, C.; Ziskoven, R.

    1982-01-01

    The isotopic distribution of stable isotopes in six enriched metals (calcium, copper, barium, rubidium, strontium and thallium) has been determined by field desorption mass spectrometry. A first evaluation of the interlaboratory reproducibility of the application of this method for trace determination of metals was made using three different types of mass spectrometers in three different laboratories. The standard deviations for the most abundant isotopes of the metals investigated are between +-0.1 and +-0.5%. Within these standard deviations, the values obtained by the three mass spectrometry groups are the same. To support the accuracy of our quantification, thermal ionization mass spectrometry has been employed and confirms the results of the field desorption method. (orig.) [de

  14. Screening halogenated environmental contaminants in biota based on isotopic pattern and mass defect provided by high resolution mass spectrometry profiling

    Energy Technology Data Exchange (ETDEWEB)

    Cariou, Ronan, E-mail: laberca@oniris-nantes.fr; Omer, Elsa; Léon, Alexis; Dervilly-Pinel, Gaud; Le Bizec, Bruno

    2016-09-14

    In the present work, we addressed the question of global seeking/screening organohalogenated compounds in a large panel of complex biological matrices, with a particular focus on unknown chemicals that may be considered as potential emerging hazards. A fishing strategy was developed based on untargeted profiling among full scan acquisition datasets provided by high resolution mass spectrometry. Since large datasets arise from such profiling, filtering useful information stands as a central question. In this way, we took advantage of the exact mass differences between Cl and Br isotopes. Indeed, our workflow involved an innovative Visual Basic for Applications script aiming at pairing features according to this mass difference, in order to point out potential organohalogenated clusters, preceded by an automated peak picking step based on the centWave function (xcms package of open access R programming environment). Then, H/Cl-scale mass defect plots were used to visualize the datasets before and after filtering. The filtering script was successfully applied to a dataset generated upon liquid chromatography coupled to ESI(−)-HRMS measurement from one eel muscle extract, allowing for realistic manual investigations of filtered clusters. Starting from 9789 initial obtained features, 1994 features were paired in 589 clusters. Hexabromocyclododecane, chlorinated paraffin series and various other compounds have been identified or tentatively identified, allowing thus broad screening of organohalogenated compounds in this extract. Although realistic, manual review of paired clusters remains time consuming and much effort should be devoted to automation. - Highlights: • We address the screening of halogenated compounds in large Full Scan HRMS datasets. • The workflow involves peak picking, pairing script and review of paired features. • The pairing script is based on exact mass differences between Cl and Br isotopes. • H/Cl scale mass defect plots are used to

  15. Screening halogenated environmental contaminants in biota based on isotopic pattern and mass defect provided by high resolution mass spectrometry profiling

    International Nuclear Information System (INIS)

    Cariou, Ronan; Omer, Elsa; Léon, Alexis; Dervilly-Pinel, Gaud; Le Bizec, Bruno

    2016-01-01

    In the present work, we addressed the question of global seeking/screening organohalogenated compounds in a large panel of complex biological matrices, with a particular focus on unknown chemicals that may be considered as potential emerging hazards. A fishing strategy was developed based on untargeted profiling among full scan acquisition datasets provided by high resolution mass spectrometry. Since large datasets arise from such profiling, filtering useful information stands as a central question. In this way, we took advantage of the exact mass differences between Cl and Br isotopes. Indeed, our workflow involved an innovative Visual Basic for Applications script aiming at pairing features according to this mass difference, in order to point out potential organohalogenated clusters, preceded by an automated peak picking step based on the centWave function (xcms package of open access R programming environment). Then, H/Cl-scale mass defect plots were used to visualize the datasets before and after filtering. The filtering script was successfully applied to a dataset generated upon liquid chromatography coupled to ESI(−)-HRMS measurement from one eel muscle extract, allowing for realistic manual investigations of filtered clusters. Starting from 9789 initial obtained features, 1994 features were paired in 589 clusters. Hexabromocyclododecane, chlorinated paraffin series and various other compounds have been identified or tentatively identified, allowing thus broad screening of organohalogenated compounds in this extract. Although realistic, manual review of paired clusters remains time consuming and much effort should be devoted to automation. - Highlights: • We address the screening of halogenated compounds in large Full Scan HRMS datasets. • The workflow involves peak picking, pairing script and review of paired features. • The pairing script is based on exact mass differences between Cl and Br isotopes. • H/Cl scale mass defect plots are used to

  16. Spatial Pattern Determination of Biodiversity Threats at Landscape Level (Case Study: Golestan Province)

    OpenAIRE

    R. Mirzaei; A. Esmaili-Sari; M. R. Hemami; H. R. Rezaei

    2015-01-01

    Mapping spatial patterns of potential biodiversity threats is one of the important steps for effective conservation planning and activities. To determine the spatial patterns of threats in Golestan province, 12 criteria in four main groups including structural (fractal coefficient of perimeter, circularity ratio of area, average slope), compositional aspects of biodiversity (presence of species at risk), non-biological threats (distance to city, distance to village, distance to road, distance...

  17. Mass determination of U-233 and Pu-239 by gamma spectrometry technique

    International Nuclear Information System (INIS)

    Moraes, M.A.P.V. de; Pugliesi, R.

    1988-09-01

    The gamma spectrometry technique has been used for masses determinations of uranium-233 and plutonium-239, granted by AERE-HARWELL. A high purity Ge semicondutor detector was used and the total efficiency curve was obtained for the counting system in the energy range 13 KeV to 135 KeV. The calculated values for the masses compared with that obtained by means of gravimetry technique. (author) [pt

  18. Calorimetric measurements of $^{163}$ holmium decay as tools to determine the electron neutrino mass

    CERN Document Server

    De Rújula, Alvaro

    1982-01-01

    Computes the spectrum of 'calorimetric' energy in the electron capture decay of /sup 163/Ho. A calorimetric experiment would yield an excellent determination of (/sup 163/Ho, /sup 163/Dy) mass difference. The proximity of the spectral endpoint to an atomic resonance makes the fraction of events that are sensitive to a non-zero neutrino mass superior in /sup 163/Ho decay than in tritium decay.

  19. Using forbidden ordinal patterns to detect determinism in irregularly sampled time series.

    Science.gov (United States)

    Kulp, C W; Chobot, J M; Niskala, B J; Needhammer, C J

    2016-02-01

    It is known that when symbolizing a time series into ordinal patterns using the Bandt-Pompe (BP) methodology, there will be ordinal patterns called forbidden patterns that do not occur in a deterministic series. The existence of forbidden patterns can be used to identify deterministic dynamics. In this paper, the ability to use forbidden patterns to detect determinism in irregularly sampled time series is tested on data generated from a continuous model system. The study is done in three parts. First, the effects of sampling time on the number of forbidden patterns are studied on regularly sampled time series. The next two parts focus on two types of irregular-sampling, missing data and timing jitter. It is shown that forbidden patterns can be used to detect determinism in irregularly sampled time series for low degrees of sampling irregularity (as defined in the paper). In addition, comments are made about the appropriateness of using the BP methodology to symbolize irregularly sampled time series.

  20. Texture one zero Dirac neutrino mass matrix with vanishing determinant or trace condition

    Science.gov (United States)

    Singh, Madan

    2018-06-01

    In the light of non-zero and relatively large value of rector mixing angle (θ13), we have performed a detailed analysis of texture one zero neutrino mass matrix Mν in the scenario of vanishing determinant/trace conditions, assuming the Dirac nature of neutrinos. In both the scenarios, normal mass ordering is ruled out for all the six possibilities of Mν, however for inverted mass ordering, only two are found to be viable with the current neutrino oscillation data at 3σ confidence level. Numerical and some approximate analytical results are presented.

  1. Proposed thermodynamic method to determine the vortex mass in layered superconductors

    International Nuclear Information System (INIS)

    Moler, K.A.; Fetter, A.L.; Kapitulnik, A.

    1995-01-01

    The authors describe a simple method to study vortex dynamics that can determine or set an upper limit on the vortex mass. The specific heat of the vortex lattice in layered superconductors has a classical limit of 1 k B per pancake vortex if the vortex mass is zero. If the vortex mass m v is finite, a new Einstein branch of normal modes will appear with a crossover temperature Θ E ∝ m v -1 , and the specific heat will saturate at a new classical limit of 2 k B per pancake vortex

  2. Differential fragmentation patterns of pectin oligogalacturonides observed by nanoelectrospray quadrupole ion-trap mass spectrometry using automated spectra interpretation

    DEFF Research Database (Denmark)

    Mutenda, Kudzai E; Matthiesen, Rune; Roepstorff, Peter

    2007-01-01

    Oligogalacturonides of different degrees of polymerization (DP) and methyl esterification (DE) were structurally analyzed by nanoESI quadrupole ion-trap mass spectrometry. The fragmentation patterns of the oligogalacturonides were compared using the program 'Virtual Expert Mass Spectrometrist...... with free carboxylic acid groups underwent higher water loss compared to fully methyl-esterified oligogalacturonides under the same fragmentation conditions. Cross-ring cleavage, in which fragmentation occurs across the ring system of the galacturonate residue and signified by unique mass losses...... water loss than methyl-esterified ones will be postulated. In addition, the VEMS program was extended to automatically interpret and assign the fragment ions peaks generated in this study....

  3. Quantitative determination of carbonaceous particle mixing state in Paris using single-particle mass spectrometer and aerosol mass spectrometer measurements

    Directory of Open Access Journals (Sweden)

    R. M. Healy

    2013-09-01

    Full Text Available Single-particle mixing state information can be a powerful tool for assessing the relative impact of local and regional sources of ambient particulate matter in urban environments. However, quantitative mixing state data are challenging to obtain using single-particle mass spectrometers. In this study, the quantitative chemical composition of carbonaceous single particles has been determined using an aerosol time-of-flight mass spectrometer (ATOFMS as part of the MEGAPOLI 2010 winter campaign in Paris, France. Relative peak areas of marker ions for elemental carbon (EC, organic aerosol (OA, ammonium, nitrate, sulfate and potassium were compared with concurrent measurements from an Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS, a thermal–optical OCEC analyser and a particle into liquid sampler coupled with ion chromatography (PILS-IC. ATOFMS-derived estimated mass concentrations reproduced the variability of these species well (R2 = 0.67–0.78, and 10 discrete mixing states for carbonaceous particles were identified and quantified. The chemical mixing state of HR-ToF-AMS organic aerosol factors, resolved using positive matrix factorisation, was also investigated through comparison with the ATOFMS dataset. The results indicate that hydrocarbon-like OA (HOA detected in Paris is associated with two EC-rich mixing states which differ in their relative sulfate content, while fresh biomass burning OA (BBOA is associated with two mixing states which differ significantly in their OA / EC ratios. Aged biomass burning OA (OOA2-BBOA was found to be significantly internally mixed with nitrate, while secondary, oxidised OA (OOA was associated with five particle mixing states, each exhibiting different relative secondary inorganic ion content. Externally mixed secondary organic aerosol was not observed. These findings demonstrate the range of primary and secondary organic aerosol mixing states in Paris. Examination of the

  4. Quantitative determination of carbonaceous particle mixing state in Paris using single-particle mass spectrometer and aerosol mass spectrometer measurements

    Science.gov (United States)

    Healy, R. M.; Sciare, J.; Poulain, L.; Crippa, M.; Wiedensohler, A.; Prévôt, A. S. H.; Baltensperger, U.; Sarda-Estève, R.; McGuire, M. L.; Jeong, C.-H.; McGillicuddy, E.; O'Connor, I. P.; Sodeau, J. R.; Evans, G. J.; Wenger, J. C.

    2013-09-01

    Single-particle mixing state information can be a powerful tool for assessing the relative impact of local and regional sources of ambient particulate matter in urban environments. However, quantitative mixing state data are challenging to obtain using single-particle mass spectrometers. In this study, the quantitative chemical composition of carbonaceous single particles has been determined using an aerosol time-of-flight mass spectrometer (ATOFMS) as part of the MEGAPOLI 2010 winter campaign in Paris, France. Relative peak areas of marker ions for elemental carbon (EC), organic aerosol (OA), ammonium, nitrate, sulfate and potassium were compared with concurrent measurements from an Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS), a thermal-optical OCEC analyser and a particle into liquid sampler coupled with ion chromatography (PILS-IC). ATOFMS-derived estimated mass concentrations reproduced the variability of these species well (R2 = 0.67-0.78), and 10 discrete mixing states for carbonaceous particles were identified and quantified. The chemical mixing state of HR-ToF-AMS organic aerosol factors, resolved using positive matrix factorisation, was also investigated through comparison with the ATOFMS dataset. The results indicate that hydrocarbon-like OA (HOA) detected in Paris is associated with two EC-rich mixing states which differ in their relative sulfate content, while fresh biomass burning OA (BBOA) is associated with two mixing states which differ significantly in their OA / EC ratios. Aged biomass burning OA (OOA2-BBOA) was found to be significantly internally mixed with nitrate, while secondary, oxidised OA (OOA) was associated with five particle mixing states, each exhibiting different relative secondary inorganic ion content. Externally mixed secondary organic aerosol was not observed. These findings demonstrate the range of primary and secondary organic aerosol mixing states in Paris. Examination of the temporal

  5. Determination of the top mass with exclusive events t->Wb->lvJPsiX

    CERN Document Server

    Chierici, Roberto

    2006-01-01

    This note presents a realistic estimate of the CMS potential for determining the top quark mass via indirect reconstruction using leptonic W decays and from the fragmentation of the b quark. The top quark mass is determined via its correlation with the invariant mass of the and the lepton from the W decay coming from the sametop. This measurement is expected to strongly reduce the systematic errors coming from the hadronic sector, which is known to be dominant indirect reconstruction methods. This analysis also presents many innovations with respect to previously published methods on the subject, and takes into account both physics and combinatorial background. The expected error on from this measurement will be presented as a function of the collected luminosity, and emphasis will be given to the determination of systematic errors, studied in great detail.

  6. Mass spectrometric determination of magnesium isotopic ratios and its corrections for electron multiplier discrimination and mass fractionation

    International Nuclear Information System (INIS)

    Deng Zhongguo

    1989-01-01

    The mass spectrometric determination of magnesium isotopic ratios by the use of uranyl nitrate added to magnesium samples to act as a binding agent is reported. Prebaking empty filaments and preheating filaments with deposited magnesium samples on its surface in a vacuum are employed to reduce the Na signal from the thenium-ribbon. Methods for correcting magnesium isotopic ratios for electron multiplier discrimination and mass fractionation are described in detail. The results of the determination of natural magnesium isotopic ratios are 25 Mg/ 24 Mg = 0.12660 (1±0.01%) and 26 Mg/ 24 Mg = 0.13938 (1±0.10%). The magnesium isotopic ratios of rich - 26 Mg-2 sample and rich- 25 Mg-1 sample are 24 Mg/ 26 Mg = 0.003463 (1±0.2%), 25 Mg/ 26 Mg = 0.001656 (±0.2%) and 24 Mg/ 25 Mg = 0.006716 (1±0.2%), 26 Mg/ 25 Mg = 0.007264 (1±0.2%) respectively

  7. Exploring the resonant vibration of thin plates: Reconstruction of Chladni patterns and determination of resonant wave numbers.

    Science.gov (United States)

    Tuan, P H; Wen, C P; Chiang, P Y; Yu, Y T; Liang, H C; Huang, K F; Chen, Y F

    2015-04-01

    The Chladni nodal line patterns and resonant frequencies for a thin plate excited by an electronically controlled mechanical oscillator are experimentally measured. Experimental results reveal that the resonant frequencies can be fairly obtained by means of probing the variation of the effective impedance of the exciter with and without the thin plate. The influence of the extra mass from the central exciter is confirmed to be insignificant in measuring the resonant frequencies of the present system. In the theoretical aspect, the inhomogeneous Helmholtz equation is exploited to derive the response function as a function of the driving wave number for reconstructing experimental Chladni patterns. The resonant wave numbers are theoretically identified with the maximum coupling efficiency as well as the maximum entropy principle. Substituting the theoretical resonant wave numbers into the derived response function, all experimental Chladni patterns can be excellently reconstructed. More importantly, the dispersion relationship for the flexural wave of the vibrating plate can be determined with the experimental resonant frequencies and the theoretical resonant wave numbers. The determined dispersion relationship is confirmed to agree very well with the formula of the Kirchhoff-Love plate theory.

  8. Determination of Interannual to Decadal Changes in Ice Sheet Mass Balance from Satellite Altimetry

    Science.gov (United States)

    Zwally, H. Jay; Busalacchi, Antonioa J. (Technical Monitor)

    2001-01-01

    A major uncertainty in predicting sea level rise is the sensitivity of ice sheet mass balance to climate change, as well as the uncertainty in present mass balance. Since the annual water exchange is about 8 mm of global sea level equivalent, the +/- 25% uncertainty in current mass balance corresponds to +/- 2 mm/yr in sea level change. Furthermore, estimates of the sensitivity of the mass balance to temperature change range from perhaps as much as - 10% to + 10% per K. Although the overall ice mass balance and seasonal and inter-annual variations can be derived from time-series of ice surface elevations from satellite altimetry, satellite radar altimeters have been limited in spatial coverage and elevation accuracy. Nevertheless, new data analysis shows mixed patterns of ice elevation increases and decreases that are significant in terms of regional-scale mass balances. In addition, observed seasonal and interannual variations in elevation demonstrate the potential for relating the variability in mass balance to changes in precipitation, temperature, and melting. From 2001, NASA's ICESat laser altimeter mission will provide significantly better elevation accuracy and spatial coverage to 86 deg latitude and to the margins of the ice sheets. During 3 to 5 years of ICESat-1 operation, an estimate of the overall ice sheet mass balance and sea level contribution will be obtained. The importance of continued ice monitoring after the first ICESat is illustrated by the variability in the area of Greenland surface melt observed over 17-years and its correlation with temperature. In addition, measurement of ice sheet changes, along with measurements of sea level change by a series of ocean altimeters, should enable direct detection of ice level and global sea level correlations.

  9. Burn-up determination of irradiated thoria samples by isotope dilution-thermal ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Jaison, P.G.; Telmore, V.M.; Shah, R.V.; Sant, V.L.; Sasibhushan, K.; Parab, A.R.; Alamelu, D.

    2010-03-01

    Burn-up was determined experimentally using thermal ionization mass spectrometry for two samples from ThO 2 bundles irradiated in KAPS-2. This involved quantitative dissolution of the irradiated fuel samples followed by separation and determination of Th, U and a stable fission product burn-up monitor in the dissolved fuel solution. Stable fission product 148 Nd was used as a burn-up monitor for determining the number of fissions. Isotope Dilution-Thermal Ionisation Mass Spectrometry (ID-TIMS) using natural U, 229 Th and enriched 142 Nd as spikes was employed for the determination of U, Th and Nd, respectively. Atom % fission values of 1.25 ± 0.03 were obtained for both the samples. 232 U content in 233 U determined by alpha spectrometry was about 500 ppm and this was higher by a factor of 5 compared to the theoretically predicted value by ORIGEN-2 code. (author)

  10. Spatial pattern of Baccharis platypoda shrub as determined by sex and life stages

    Science.gov (United States)

    Fonseca, Darliana da Costa; de Oliveira, Marcio Leles Romarco; Pereira, Israel Marinho; Gonzaga, Anne Priscila Dias; de Moura, Cristiane Coelho; Machado, Evandro Luiz Mendonça

    2017-11-01

    Spatial patterns of dioecious species can be determined by their nutritional requirements and intraspecific competition, apart from being a response to environmental heterogeneity. The aim of the study was to evaluate the spatial pattern of populations of a dioecious shrub reporting to sex and reproductive stage patterns of individuals. Sampling was carried out in three areas located in the meridional portion of Serra do Espinhaço, where in individuals of the studied species were mapped. The spatial pattern was determined through O-ring analysis and Ripley's K-function and the distribution of individuals' frequencies was verified through x2 test. Populations in two areas showed an aggregate spatial pattern tending towards random or uniform according to the observed scale. Male and female adults presented an aggregate pattern at smaller scales, while random and uniform patterns were verified above 20 m for individuals of both sexes of the areas A2 and A3. Young individuals presented an aggregate pattern in all areas and spatial independence in relation to adult individuals, especially female plants. The interactions between individuals of both genders presented spatial independence with respect to spatial distribution. Baccharis platypoda showed characteristics in accordance with the spatial distribution of savannic and dioecious species, whereas the population was aggregated tending towards random at greater spatial scales. Young individuals showed an aggregated pattern at different scales compared to adults, without positive association between them. Female and male adult individuals presented similar characteristics, confirming that adult individuals at greater scales are randomly distributed despite their distinct preferences for environments with moisture variation.

  11. Determining Mass and Persistence of a Reactive Brominated-Solvent DNAPL Source Using Mass Depletion-Mass Flux Reduction Relationships During Pumping

    Science.gov (United States)

    Johnston, C. D.; Davis, G. B.; Bastow, T.; Annable, M. D.; Trefry, M. G.; Furness, A.; Geste, Y.; Woodbury, R.; Rhodes, S.

    2011-12-01

    Measures of the source mass and depletion characteristics of recalcitrant dense non-aqueous phase liquid (DNAPL) contaminants are critical elements for assessing performance of remediation efforts. This is in addition to understanding the relationships between source mass depletion and changes to dissolved contaminant concentration and mass flux in groundwater. Here we present results of applying analytical source-depletion concepts to pumping from within the DNAPL source zone of a 10-m thick heterogeneous layered aquifer to estimate the original source mass and characterise the time trajectory of source depletion and mass flux in groundwater. The multi-component, reactive DNAPL source consisted of the brominated solvent tetrabromoethane (TBA) and its transformation products (mostly tribromoethene - TriBE). Coring and multi-level groundwater sampling indicated the DNAPL to be mainly in lower-permeability layers, suggesting the source had already undergone appreciable depletion. Four simplified source dissolution models (exponential, power function, error function and rational mass) were able to describe the concentration history of the total molar concentration of brominated organics in extracted groundwater during 285 days of pumping. Approximately 152 kg of brominated compounds were extracted. The lack of significant kinetic mass transfer limitations in pumped concentrations was notable. This was despite the heterogeneous layering in the aquifer and distribution of DNAPL. There was little to choose between the model fits to pumped concentration time series. The variance of groundwater velocities in the aquifer determined during a partitioning inter-well tracer test (PITT) were used to parameterise the models. However, the models were found to be relatively insensitive to this parameter. All models indicated an initial source mass around 250 kg which compared favourably to an estimate of 220 kg derived from the PITT. The extrapolated concentrations from the

  12. Improved peak detection in mass spectrum by incorporating continuous wavelet transform-based pattern matching.

    Science.gov (United States)

    Du, Pan; Kibbe, Warren A; Lin, Simon M

    2006-09-01

    A major problem for current peak detection algorithms is that noise in mass spectrometry (MS) spectra gives rise to a high rate of false positives. The false positive rate is especially problematic in detecting peaks with low amplitudes. Usually, various baseline correction algorithms and smoothing methods are applied before attempting peak detection. This approach is very sensitive to the amount of smoothing and aggressiveness of the baseline correction, which contribute to making peak detection results inconsistent between runs, instrumentation and analysis methods. Most peak detection algorithms simply identify peaks based on amplitude, ignoring the additional information present in the shape of the peaks in a spectrum. In our experience, 'true' peaks have characteristic shapes, and providing a shape-matching function that provides a 'goodness of fit' coefficient should provide a more robust peak identification method. Based on these observations, a continuous wavelet transform (CWT)-based peak detection algorithm has been devised that identifies peaks with different scales and amplitudes. By transforming the spectrum into wavelet space, the pattern-matching problem is simplified and in addition provides a powerful technique for identifying and separating the signal from the spike noise and colored noise. This transformation, with the additional information provided by the 2D CWT coefficients can greatly enhance the effective signal-to-noise ratio. Furthermore, with this technique no baseline removal or peak smoothing preprocessing steps are required before peak detection, and this improves the robustness of peak detection under a variety of conditions. The algorithm was evaluated with SELDI-TOF spectra with known polypeptide positions. Comparisons with two other popular algorithms were performed. The results show the CWT-based algorithm can identify both strong and weak peaks while keeping false positive rate low. The algorithm is implemented in R and will be

  13. Determination of neutrino mass hierarchy by 21 cm line and CMB B-mode polarization observations

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Yoshihiko, E-mail: oyamayo@post.kek.jp [The Graduate University for Advanced Studies (SOKENDAI), 1-1 Oho, Tsukuba 305-0801 (Japan); Shimizu, Akie [The Graduate University for Advanced Studies (SOKENDAI), 1-1 Oho, Tsukuba 305-0801 (Japan); Kohri, Kazunori [The Graduate University for Advanced Studies (SOKENDAI), 1-1 Oho, Tsukuba 305-0801 (Japan); Institute of Particle and Nuclear Studies, KEK, 1-1 Oho, Tsukuba 305-0801 (Japan)

    2013-01-29

    We focus on the ongoing and future observations for both the 21 cm line and the CMB B-mode polarization produced by a CMB lensing, and study their sensitivities to the effective number of neutrino species, the total neutrino mass, and the neutrino mass hierarchy. We find that combining the CMB observations with future square kilometer arrays optimized for 21 cm line such as Omniscope can determine the neutrino mass hierarchy at 2{sigma}. We also show that a more feasible combination of Planck + POLARBEAR and SKA can strongly improve errors of the bounds on the total neutrino mass and the effective number of neutrino species to be {Delta}{Sigma}m{sub {nu}}{approx}0.12 eV and {Delta}N{sub {nu}}{approx}0.38 at 2{sigma}, respectively.

  14. Determination of ultra-low levels of uranium using resonance ionization mass spectrometry

    International Nuclear Information System (INIS)

    Kiran Kumar, P.V.; Acharyulu, G.V.S.G.

    2015-01-01

    The determination of isotopic composition of actinides like U and Pu is important, due to their distribution in the environment as a result of nuclear weapons testing, fuel reprocessing, reactor operations and to a smaller extent from accidental releases. The analytical methods like fission track analysis (FTA), thermal ionization mass spectrometry (TIMS), inductively coupled plasma mass spectrometry (ICPMS) and resonance ionization mass spectrometry (RIMS) have evolved as sensitive techniques. Resonance Ionization Mass Spectrometry yields rapid isotopic signature data for material containing actinides without requiring time-consuming sample preparation and chemical separation procedures. In this paper, authors presented the details of the methodology and results for low-level detection of uranium using RIMS

  15. Determination of the LEP centre-of-mass energy from Z$\\gamma$ events

    CERN Document Server

    Barate, R.; Ghez, Philippe; Goy, C.; Jezequel, S.; Lees, J.P.; Martin, F.; Merle, E.; Minard, M.N.; Pietrzyk, B.; Przysiezniak, H.; Alemany, R.; Casado, M.P.; Chmeissani, M.; Crespo, J.M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, L.; Grauges, E.; Juste, A.; Martinez, M.; Merino, G.; Miquel, R.; Mir, L.M.; Morawitz, P.; Pacheco, A.; Park, I.C.; Riu, I.; Colaleo, A.; Creanza, D.; De Palma, M.; Iaselli, G.; Maggi, G.; Maggi, M.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Becker, U.; Boix, G.; Cattaneo, M.; Cerutti, F.; Ciulli, V.; Dissertori, G.; Drevermann, H.; Forty, R.W.; Frank, M.; Gianotti, F.; Greening, T.C.; Halley, A.W.; Hansen, J.B.; Harvey, John; Janot, P.; Jost, B.; Lehraus, I.; Leroy, O.; Loomis, C.; Maley, P.; Mato, P.; Minten, A.; Moutoussi, A.; Ranjard, F.; Rolandi, Gigi; Schlatter, D.; Schmitt, M.; Schneider, O.; Spagnolo, P.; Tejessy, W.; Teubert, F.; Tomalin, I.R.; Tournefier, E.; Wright, A.E.; Ajaltouni, Z.; Badaud, F.; Chazelle, G.; Deschamps, O.; Dessagne, S.; Falvard, A.; Ferdi, C.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.C.; Pallin, D.; Perret, P.; Podlyski, F.; Hansen, J.D.; Hansen, J.R.; Hansen, P.H.; Nilsson, B.S.; Rensch, B.; Waananen, A.; Daskalakis, G.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Vayaki, A.; Blondel, A.; Brient, J.C.; Machefert, F.; Rouge, A.; Swynghedauw, M.; Tanaka, R.; Valassi, A.; Videau, H.; Focardi, E.; Parrini, G.; Zachariadou, K.; Cavanaugh, R.; Corden, M.; Georgiopoulos, C.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Chiarella, V.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G.P.; Passalacqua, L.; Pepe-Altarelli, M.; Chalmers, M.; Curtis, L.; Lynch, J.G.; Negus, P.; O'Shea, V.; Raeven, B.; Raine, C.; Smith, D.; Teixeira-Dias, P.; Thompson, A.S.; Ward, J.J.; Buchmuller, O.; Dhamotharan, S.; Geweniger, C.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E.E.; Putzer, A.; Sommer, J.; Tittel, K.; Werner, S.; Wunsch, M.; Beuselinck, R.; Binnie, D.M.; Cameron, W.; Dornan, P.J.; Girone, M.; Goodsir, S.; Marinelli, N.; Martin, E.B.; Nash, J.; Nowell, J.; Sciaba, A.; Sedgbeer, J.K.; Thomson, Evelyn J.; Williams, M.D.; Ghete, V.M.; Girtler, P.; Kneringer, E.; Kuhn, D.; Rudolph, G.; Bowdery, C.K.; Buck, P.G.; Ellis, G.; Finch, A.J.; Foster, F.; Hughes, G.; Jones, R.W.L.; Robertson, N.A.; Smizanska, M.; Williams, M.I.; Giehl, I.; Holldorfer, F.; Jakobs, K.; Kleinknecht, K.; Krocker, M.; Muller, A.S.; Nurnberger, H.A.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.G.; Schmeling, S.; Wachsmuth, H.; Zeitnitz, C.; Ziegler, T.; Aubert, J.J.; Benchouk, C.; Bonissent, A.; Carr, J.; Coyle, P.; Ealet, A.; Fouchez, D.; Motsch, F.; Payre, P.; Rousseau, D.; Talby, M.; Thulasidas, M.; Tilquin, A.; Aleppo, M.; Antonelli, M.; Gilardoni, Simone S.; Ragusa, F.; Buescher, Volker; Dietl, H.; Ganis, G.; Huttmann, K.; Lutjens, G.; Mannert, C.; Manner, W.; Moser, H.G.; Schael, S.; Settles, R.; Seywerd, H.; Stenzel, H.; Wiedenmann, W.; Wolf, G.; Azzurri, P.; Boucrot, J.; Callot, O.; Chen, S.; Davier, M.; Duflot, L.; Grivaz, J.F.; Heusse, P.; Jacholkowska, A.; Kado, M.; Lefrancois, J.; Serin, L.; Veillet, J.J.; Videau, I.; de Viviede Regie, J.B.; Zerwas, D.; Bagliesi, Giuseppe; Bettarini, S.; Boccali, T.; Bozzi, C.; Calderini, G.; Dell'Orso, R.; Ferrante, I.; Giassi, A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P.S.; Messineo, A.; Palla, F.; Rizzo, G.; Sanguinetti, G.; Sguazzoni, G.; Tenchini, R.; Vannini, C.; Venturi, A.; Verdini, P.G.; Blair, G.A.; Coles, J.; Cowan, G.; Green, M.G.; Hutchcroft, D.E.; Jones, L.T.; Medcalf, T.; Strong, J.A.; von Wimmersperg-Toeller, J.H.; Botterill, D.R.; Clifft, R.W.; Edgecock, T.R.; Norton, P.R.; Thompson, J.C.; Bloch-Devaux, Brigitte; Colas, P.; Fabbro, B.; Faif, G.; Lancon, E.; Lemaire, M.C.; Locci, E.; Perez, P.; Rander, J.; Renardy, J.F.; Rosowsky, A.; Trabelsi, A.; Tuchming, B.; Vallage, B.; Black, S.N.; Dann, J.H.; Kim, H.Y.; Konstantinidis, N.; Litke, A.M.; McNeil, M.A.; Taylor, G.; Booth, C.N.; Cartwright, S.; Combley, F.; Hodgson, P.N.; Kelly, M.S.; Lehto, M.; Thompson, L.F.; Affholderbach, K.; Boehrer, Armin; Brandt, S.; Grupen, C.; Hess, J.; Misiejuk, A.; Prange, G.; Sieler, U.; Giannini, G.; Gobbo, B.; Putz, J.; Rothberg, J.; Wasserbaech, S.; Williams, R.W.; Armstrong, S.R.; Elmer, P.; Ferguson, D.P.S.; Gao, Y.; Gonzalez, S.; Hayes, O.J.; Hu, H.; Jin, S.; McNamara, P.A., III; Nielsen, J.; Orejudos, W.; Pan, Y.B.; Saadi, Y.; Scott, I.J.; Walsh, J.; Wu, Sau Lan; Wu, X.; Zobernig, G.

    1999-01-01

    Radiative returns to the Z resonance (Z\\gamma events) are used to determine the LEP2 centre-of-mass energy from the data collected with the ALEPH detector in 1997. The average centre-of-mass energy is measured to be: E_CM = 182.50 +- 0.19 (stat.) +- 0.08 (syst.) GeV in good agreement with the precise determination by the LEP energy working group of 182.652 +- 0.050 GeV. If applied to the measurement of the W mass, its precision translates into a systematic error on M_W which is smaller than the statistical error achieved from the corresponding dataset.

  16. Structural features of lipoarabinomannan from Mycobacterium bovis BCG. Determination of molecular mass by laser desorption mass spectrometry.

    Science.gov (United States)

    Venisse, A; Berjeaud, J M; Chaurand, P; Gilleron, M; Puzo, G

    1993-06-15

    It was recently shown that mycobacterial lipoarabinomannan (LAM) can be classified into two types (Chatterjee, D., Lowell, K., Rivoire B., McNeil M. R., and Brennan, P. J. (1992) J. Biol. Chem. 267, 6234-6239) according to the presence or absence of mannosyl residues (Manp) located at the nonreducing end of the oligoarabinosyl side chains. These two types of LAM were found in a pathogenic Mycobacterium tuberculosis strain and in an avirulent M. tuberculosis strain, respectively, suggesting that LAM with Manp characterizes virulent and "disease-inducing strains." We now report the structure of the LAM from Mycobacterium bovis Bacille Calmette-Guérin (BCG) strain Pasteur, largely used throughout the world as vaccine against tuberculosis. Using an up-to-date analytical approach, we found that the LAM of M. bovis BCG belongs to the class of LAMs capped with Manp. By means of two-dimensional homonuclear and heteronuclear scalar coupling NMR analysis and methylation data, the sugar spin system assignments were partially established, revealing that the LAM contained two types of terminal Manp and 2-O-linked Manp. From the following four-step process: (i) partial hydrolysis of deacylated LAM (dLAM), (ii) oligosaccharide derivatization with aminobenzoic ethyl ester, (iii) HPLC purification, (iv) FAB/MS-MS analysis; it was shown that the dimannosyl unit alpha-D-Manp-(1-->2)-alpha-D-Manp is the major residue capping the termini of the arabinan of the LAM. In this report, LAM molecular mass determination was established using matrix-assisted UV-laser desorption/ionization mass spectrometry which reveals that the LAM molecular mass is around 17.4 kDa. The similarity of the LAM structures between M. bovis BCG and M. tuberculosis H37Rv is discussed in regard to their function in the immunopathology of mycobacterial infection.

  17. Determination of aromatic amines in aqueous extracts of polyurethane foam using hydrophilic interaction liquid chromatography and mass spectrometry

    International Nuclear Information System (INIS)

    Riddar Johnson, Jakob; Karlsson, Daniel; Dalene, Marianne; Skarping, Gunnar

    2010-01-01

    A method is presented for the determination of aromatic amines in aqueous extracts of polyurethane (PUR) foam. The method is based on the extraction of PUR foam using aqueous acetic acid (0.1%, w/v) followed by determination of extracted aromatic amines using hydrophilic interaction liquid chromatography (HILIC) and tandem mass spectrometry (MS/MS) with positive electrospray ionisation. The injections of volumes up to 5 μL of aqueous solutions were made possible by on-column focusing with partially filled loop injections. The fragmentation patterns for 2,4- and 2,6-toluene diamine (TDA) and 4,4'-methylene dianiline (MDA) were clarified by performing a hydrogen-deuterium exchange study. TDA and MDA were determined using trideuterated 2,4- and 2,6-TDA and dideuterated 4,4'-MDA as internal standards. Linear calibration graphs were obtained over the range 0.025-0.5 μg mL -1 with correlation coefficients >0.996 and the instrumental detection limit for each compound was <50 fmol. The stability of the amines was influenced by the matrix, so their concentrations decreased over time. Agreement was observed between the results of analyses of PUR foam extracts by HILIC-MS/MS and results obtained by ethyl chloroformate derivatisation and reversed phase (RP) liquid chromatography-mass spectrometry (LC-MS/MS). TDA was observed to be unstable in extracts of foam but not in pure solutions.

  18. Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometry

    NARCIS (Netherlands)

    van der Lijke, H.; Alffenaar, J.-W. C.; Kok, W.Th.; Greijdanus, B.; Uges, D.R.A.

    2012-01-01

    A method has been developed for the determination of ribavirin in human serum for therapeutic drug monitoring purposes, using liquid chromatography electrospray ionization mass spectrometry. Separation was obtained with a mobile phase gradient starting and ending in 100% aqueous conditions using a

  19. Reliability and validity of non-invasive determined haemoglobin mass and blood volumes

    DEFF Research Database (Denmark)

    Fagoni, Nazzareno; Andersen, Andreas Breenfeldt; Oberholzer, Laura

    2018-01-01

    INTRODUCTION: The carbon monoxide (CO) rebreathing method used for the determination of haemoglobin mass (Hbmass ) is associated with blood sample analysis (in this study: Radiometer ABL800). As an alternative hereto the aim of the present study was to evaluate the use of a portable and non-invas...

  20. Experimental conditions for determination of the neutrino mass hierarchy with reactor antineutrinos

    Directory of Open Access Journals (Sweden)

    Myoung Youl Pac

    2016-01-01

    Full Text Available This article reports the optimized experimental requirements to determine neutrino mass hierarchy using electron antineutrinos (ν¯e generated in a nuclear reactor. The features of the neutrino mass hierarchy can be extracted from the |Δm312| and |Δm322| oscillations by applying the Fourier sine and cosine transforms to the L/E spectrum. To determine the neutrino mass hierarchy above 90% probability, the requirements on the energy resolution as a function of the baseline are studied at sin2⁡2θ13=0.1. If the energy resolution of the neutrino detector is less than 0.04/Eν and the determination probability obtained from Bayes' theorem is above 90%, the detector needs to be located around 48–53 km from the reactor(s to measure the energy spectrum of ν¯e. These results will be helpful for setting up an experiment to determine the neutrino mass hierarchy, which is an important problem in neutrino physics.

  1. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  2. Determination of the gas-to-membrane mass transfer coefficient in a catalytic membrane reactor

    NARCIS (Netherlands)

    Veldsink, J.W.; Versteeg, G.F.; Swaaij, W.P.M. van

    1995-01-01

    A novel method to determine the external mass transfer coefficient in catalytic membrane reactors (Sloot et al., 1992a, b) was presented in this study. In a catalytically active membrane reactor, in which a very fast reaction occurs, the external transfer coefficient can conveniently be measured by

  3. Determination of organophosphorus acids by thermo-spray liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Wils, E.R.J.; Hulst, A.G.

    1988-01-01

    The determination of thirteen organophosphorus acids, hydrolysis products of nerve agents and pesticides, by a combination of ion-pair liquid chromatography on a reversed-phase C18 column and thermospray mass spectrometry was investigated. Ammonium acetate and three tetraalkylammonium salts with

  4. Determination of platinum in human subcellular microsamples by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Björn, Erik; Nygren, Yvonne; Nguyen, Tam T. T. N.

    2007-01-01

    A fast and robust method for the determination of platinum in human subcellular microsamples by inductively coupled plasma mass spectrometry was developed, characterized, and validated. Samples of isolated DNA and exosome fractions from human ovarian (2008) and melanoma (T289) cancer cell lines w...

  5. Mass determination of Λ 0 and anti-Λ0 produced by pp reactions

    International Nuclear Information System (INIS)

    Buenrostro C, E.A.; Quintero G, G.I.; Felix, J.

    1997-01-01

    It was determined the mass of the hyperon Λ 0 and of the anti-hyperon anti-Λ 0 , during the second scientific research summer. Both hyperons were collected from inclusive and exclusive proton-proton collisions. The results are in excellent agreement with the universally accepted values. In this paper we compare both values and discuss their theoretical consequences. (Author)

  6. Determination of chlormequat in pears by liquid chromatography/mass spectrometry

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Vreeken, R.J.; Steijger, O.M.

    2000-01-01

    A straightforward and reliable method was developed for the determination of chlormequat in pears by liquid chromatography/mass spectrometry (LC/MS). Water and methanol were compared as extraction solvents. Because no significant differences in extraction efficiency or repeatability were found,

  7. Effects of 14-day oral low dose selenium nanoparticles and selenite in rat—as determined by metabolite pattern determination

    Directory of Open Access Journals (Sweden)

    Niels Hadrup

    2016-10-01

    Full Text Available Selenium (Se is an essential element with a small difference between physiological and toxic doses. To provide more effective and safe Se dosing regimens, as compared to dosing with ionic selenium, nanoparticle formulations have been developed. However, due to the nano-formulation, unexpected toxic effects may occur. We used metabolite pattern determination in urine to investigate biological and/or toxic effects in rats administered nanoparticles and for comparison included ionic selenium at an equimolar dose in the form of sodium selenite. Low doses of 10 and 100 fold the recommended human high level were employed to study the effects at borderline toxicity. Evaluations of all significantly changed putative metabolites, showed that Se nanoparticles and sodium selenite induced similar dose dependent changes of the metabolite pattern. Putative identified metabolites included increased decenedioic acid and hydroxydecanedioic acid for both Se formulations whereas dipeptides were only increased for selenite. These effects could reflect altered fatty acid and protein metabolism, respectively.

  8. Pattern placement errors: application of in-situ interferometer-determined Zernike coefficients in determining printed image deviations

    Science.gov (United States)

    Roberts, William R.; Gould, Christopher J.; Smith, Adlai H.; Rebitz, Ken

    2000-08-01

    Several ideas have recently been presented which attempt to measure and predict lens aberrations for new low k1 imaging systems. Abbreviated sets of Zernike coefficients have been produced and used to predict Across Chip Linewidth Variation. Empirical use of the wavefront aberrations can now be used in commercially available lithography simulators to predict pattern distortion and placement errors. Measurement and Determination of Zernike coefficients has been a significant effort of many. However the use of this data has generally been limited to matching lenses or picking best fit lense pairs. We will use wavefront aberration data collected using the Litel InspecStep in-situ Interferometer as input data for Prolith/3D to model and predict pattern placement errors and intrafield overlay variation. Experiment data will be collected and compared to the simulated predictions.

  9. Determination of trace amounts of impurities in molybdenum by spark source and glow discharge mass spectrometry

    International Nuclear Information System (INIS)

    Saito, Morimasa

    1994-01-01

    For the determination of trace and ultra-trace amounts of impurities in high-purity molybdenum, spark source mass spectrometry and glow discharge mass spectrometry were studied. In spark source mass spectrometry using the metal probe method, the liquid-helium cryogenic pump was used in order to protect the surface of the samples from oxidation. The theoretical relative sensitivity factors (Mo=1) calculated from physical properties were used. The analytical results obtained for molybdenum tablet and high-purity molybdenum were in good agreement with those obtained by other methods (atomic absorption spectrometry and others). In glow discharge mass spectrometry, the relative sensitivity factors were calculated by using the results obtained by spark source mass spectrometry and atomic absorption spectrometry, and this method was applied to the determination of ultra-trace amounts of impurities in ultra high-purity molybdenum and gave the satisfactory results. The detection limits (2σ, n=10) in the integration time of 600 s for U and Th were 0.6 ppb and 0.3 ppb, and the values for Al, Si, Cr, Mn and Cu were in the range of 10 ppb to 0.5 ppb. (author)

  10. The effect of nuclear gas distribution on the mass determination of supermassive black holes

    Science.gov (United States)

    Mejía-Restrepo, J. E.; Lira, P.; Netzer, H.; Trakhtenbrot, B.; Capellupo, D. M.

    2018-01-01

    Supermassive black holes reside in the nuclei of most galaxies. During their active episodes, black holes are powered by accretion discs where gravitational energy is converted into radiation1. Accurately determining black hole masses is key to understand how the population evolves over time and how the black holes relate to their host galaxies2-4. Beyond the local universe, z ≳ 0.2, the mass is commonly estimated assuming a virialized motion of gas in the close vicinity of the active black holes, traced through broad emission lines5,6. However, this procedure has uncertainties associated with the unknown distribution of the gas clouds. Here, we show that the black hole masses derived from the properties of the accretion disk and virial mass estimates differ by a factor that is inversely proportional to the width of the broad emission lines. This leads to virial mass misestimations up to a factor of six. Our results suggest that a planar gas distribution that is inclined with respect to the line of sight may account for this effect. However, radiation pressure effects on the distribution of gas can also reproduce our results. Regardless of the physical origin, our findings contribute to mitigating the uncertainties in current black hole mass estimations and, in turn, will help us to better understand the evolution of distant supermassive black holes and their host galaxies.

  11. Value of radio density determined by enhanced computed tomography for the differential diagnosis of lung masses

    International Nuclear Information System (INIS)

    Xie, Min

    2011-01-01

    Lung masses are often difficult to differentiate when their clinical symptoms and shapes or densities on computed tomography images are similar. However, with different pathological contents, they may appear differently on plain and enhanced computed tomography. Objectives: To determine the value of enhanced computed tomography for the differential diagnosis of lung masses based on the differences in radio density with and without enhancement. Patients and Methods: Thirty-six patients with lung cancer, 36 with pulmonary tuberculosis and 10 with inflammatory lung pseudo tumors diagnosed by computed tomography and confirmed by pathology in our hospital were selected. The mean ±SD radio densities of lung masses in the three groups of patients were calculated based on the results of plain and enhanced computed tomography. Results: There were no significant differences in the radio densities of the masses detected by plain computed tomography among patients with inflammatory lung pseudo tumors, tuberculosis and lung cancer (P> 0.05). However, there were significant differences (P< 0.01)between all the groups in terms of radio densities of masses detected by enhanced computed tomography. Conclusions: The radio densities of lung masses detected by enhanced computed tomography could potentially be used to differentiate between lung cancer, pulmonary tuberculosis and inflammatory lung pseudo tumors.

  12. Urban-rural difference in the determinants of dietary and energy intake patterns: A case study in West Java, Indonesia.

    Science.gov (United States)

    Kosaka, Satoko; Suda, Kazuhiro; Gunawan, Budhi; Raksanagara, Ardini; Watanabe, Chiho; Umezaki, Masahiro

    2018-01-01

    Few studies have explored differences in the determinants of individual dietary/energy intake patterns between urban and rural areas. To examine whether the associations between individual characteristics and dietary/energy intake patterns differ between urban and rural areas in West Java, Indonesia. A 3-day weighed food record, interviews, and anthropometric measurements were conducted in Bandung (urban area; n = 85) and Sumedang (rural area; n = 201). Total energy intake and intake from protein, fat, and carbohydrates were calculated. Food items were grouped into dietary categories based on the main ingredients to calculate their share of total energy intake. The associations between individual characteristics and dietary/energy intake were examined by fitting regression models. Models that also included education and body mass index (BMI) were fitted to adult samples only. In Sumedang, the total energy intake and energy intake from carbohydrates, fat, and grain/tubers were significantly associated with age and occupation. In Bandung, energy intake from grain/tubers and vegetables/legumes was related to sex and occupation, while other indicators showed no associations. Among adults, BMI was associated with the total energy intake and educational level was associated with energy intake from vegetables/legumes (both only in Sumedang). The relationship between demographic and socioeconomic factors and dietary/energy intake patterns differs in rural versus urban areas in West Java. These results suggest that different strategies are needed in rural and urban areas to identify and aid populations at risk of diet-related diseases.

  13. Determination of the pattern of nuclear binding from the data on the lepton-nucleus deep inelastic scattering

    International Nuclear Information System (INIS)

    Smirnov, G.I.

    1999-01-01

    Nucleon structure function ratios r A (x) = F 2 A (x) / F 2 D (x) measured in the range of atomic masses A ≥ 4 are analyzed with the aim to determine the pattern of the x and A dependence of F 2 (x) modifications caused by nuclear environment. It is found that the x and A dependence of the deviations of the r A (x) from unity can be factorized in the entire range of x. The characteristic feature of the factorization is represented with the three cross-over points x i , i = 1 - 3 in which r A (x) = 1 independently of A. In the range x > 0.7 the pattern of r A (x) is fixed with x 3 = 0.84 ± 0.01. The pattern of the x dependence is compared with theoretical calculations of Burov, Molochkov and Smirnov to demonstrate that evolution of the nucleon structure as a function of A occurs in two steps, first for A ≤ 4 and second for A > 4. The long-standing problem of the origin of the EMC effect is understood as the modification of the nucleon structure in the field responsible for the binding forces in a three-nucleon system

  14. DETERMINATION OF CO2 MASSES IN THE EXHAUST GASES OF THE MARINE DIESEL ENGINES

    Directory of Open Access Journals (Sweden)

    Doru COSOFRET

    2016-05-01

    Full Text Available Currently, reducing CO2 emissions that contribute to the greenhouse effect is currently under attention of the relevant international bodies. In the field of maritime transport, in 2011 International Maritime Organization (IMO has taken steps to reduce emissions of CO2 from the exhaust gases of marine diesel engines on ships, by imposing their energy efficiency standards. In this regard, we conducted a laboratory study on a 4-stroke diesel engine naturally aspirated by using to power it diesel and different blends of biodiesel with diesel fuel. The purpose of the study was to determine the formulas for calculating the mass flow rates of CO2 from exhaust gases’ concentrations experimentally determined. Determining the mass flow of CO2 is necessary to calculate the energy efficiency coefficient of the ship to assess the energy efficiency of the board of the limits imposed by the IMO.

  15. Protein Adsorption Patterns and Analysis on IV Nanoemulsions—The Key Factor Determining the Organ Distribution

    Directory of Open Access Journals (Sweden)

    Mirko Jansch

    2012-12-01

    Full Text Available Intravenous nanoemulsions have been on the market for parenteral nutrition since the 1950s; meanwhile, they have also been used successfully for IV drug delivery. To be well tolerable, the emulsions should avoid uptake by the MPS cells of the body; for drug delivery, they should be target-specific. The organ distribution is determined by the proteins adsorbing them after injection from the blood (protein adsorption pattern, typically analyzed by two-dimensional polyacrylamide gel electrophoresis, 2-D PAGE. The article reviews the 2-D PAGE method, the analytical problems to be faced and the knowledge available on how the composition of emulsions affects the protein adsorption patterns, e.g., the composition of the oil phase, stabilizer layer and drug incorporation into the interface or oil core. Data were re-evaluated and compared, and the implications for the in vivo distribution are discussed. Major results are that the interfacial composition of the stabilizer layer is the main determining factor and that this composition can be modulated by simple processes. Drug incorporation affects the pattern depending on the localization of the drug (oil core versus interface. The data situation regarding in vivo effects is very limited; mainly, it has to be referred to in the in vivo data of polymeric nanoparticles. As a conclusion, determination of the protein adsorption patterns can accelerate IV nanoemulsion formulation development regarding optimized organ distribution and related pharmacokinetics.

  16. Protein Adsorption Patterns and Analysis on IV Nanoemulsions-The Key Factor Determining the Organ Distribution.

    Science.gov (United States)

    Keck, Cornelia M; Jansch, Mirko; Müller, Rainer H

    2012-12-21

    Intravenous nanoemulsions have been on the market for parenteral nutrition since the 1950s; meanwhile, they have also been used successfully for IV drug delivery. To be well tolerable, the emulsions should avoid uptake by the MPS cells of the body; for drug delivery, they should be target-specific. The organ distribution is determined by the proteins adsorbing them after injection from the blood (protein adsorption pattern), typically analyzed by two-dimensional polyacrylamide gel electrophoresis, 2-D PAGE. The article reviews the 2-D PAGE method, the analytical problems to be faced and the knowledge available on how the composition of emulsions affects the protein adsorption patterns, e.g., the composition of the oil phase, stabilizer layer and drug incorporation into the interface or oil core. Data were re-evaluated and compared, and the implications for the in vivo distribution are discussed. Major results are that the interfacial composition of the stabilizer layer is the main determining factor and that this composition can be modulated by simple processes. Drug incorporation affects the pattern depending on the localization of the drug (oil core versus interface). The data situation regarding in vivo effects is very limited; mainly, it has to be referred to in the in vivo data of polymeric nanoparticles. As a conclusion, determination of the protein adsorption patterns can accelerate IV nanoemulsion formulation development regarding optimized organ distribution and related pharmacokinetics.

  17. The traditional lunch pattern is inversely correlated with body mass index in a population-based study in Brazil

    Directory of Open Access Journals (Sweden)

    Roberta de Oliveira Santos

    2017-07-01

    Full Text Available Abstract Background The association of obesity and dietary patterns has been well documented in scientific literature; however, information on the impact of meal patterns on obesity is scarce. The objective of this study was to investigate the association of adherence to lunch patterns and body mass index (BMI in a representative sample of individuals aged 20 years or older in Sao Paulo. Methods Data for 933 participants were retrieved from the Health Survey of São Paulo (ISA-Capital 2008, a cross-sectional population-based survey. The usual dietary intake of individuals with at least one 24-h recall was estimated by the Multiple Source Method. The definition of lunch was self-reported by the participant. Five lunch patterns were derived from twenty-two food groups by exploratory factor analysis: Traditional, Western, Sweetened juice, Salad, and Meats. To estimate the effect of lunch patterns on BMI, we used a generalized linear model with link identity and inverse Gaussian distribution. Analyses were adjusted by age, gender, household income per capita, physical activity levels, smoking status, alcohol consumption, total energy intake, and misreporting status. Results The greater adherence to the traditional pattern at the lunch meal was associated with lower BMI, only in insufficiently active individuals (ß = −0.78; 95% CI -1.57; −0.02. Conclusions The traditional Brazilian lunch pattern might protect the insufficiently active individuals against obesity.

  18. Determination of mass density, dielectric, elastic, and piezoelectric constants of bulk GaN crystal.

    Science.gov (United States)

    Soluch, Waldemar; Brzozowski, Ernest; Lysakowska, Magdalena; Sadura, Jolanta

    2011-11-01

    Mass density, dielectric, elastic, and piezoelectric constants of bulk GaN crystal were determined. Mass density was obtained from the measured ratio of mass to volume of a cuboid. The dielectric constants were determined from the measured capacitances of an interdigital transducer (IDT) deposited on a Z-cut plate and from a parallel plate capacitor fabricated from this plate. The elastic and piezoelectric constants were determined by comparing the measured and calculated SAW velocities and electromechanical coupling coefficients on the Z- and X-cut plates. The following new constants were obtained: mass density p = 5986 kg/m(3); relative dielectric constants (at constant strain S) ε(S)(11)/ε(0) = 8.6 and ε(S)(11)/ε(0) = 10.5, where ε(0) is a dielectric constant of free space; elastic constants (at constant electric field E) C(E)(11) = 349.7, C(E)(12) = 128.1, C(E)(13) = 129.4, C(E)(33) = 430.3, and C(E)(44) = 96.5 GPa; and piezoelectric constants e(33) = 0.84, e(31) = -0.47, and e(15) = -0.41 C/m(2).

  19. Precision determination of pion mass using X-ray CCD spectroscopy

    CERN Document Server

    Nelms, N; Augsburger, M A; Borchert, G; Chatellard, D; Daum, M; Egger, J P; Gotta, D; Hauser, P; Indelicato, P J; Jeannet, E; Kirch, K; Schult, O W B; Siems, T; Simons, L M; Wells, A

    2002-01-01

    An experiment is described which aims to determine the charged pion mass to 1 ppm or better, from which a new determination of the upper limit of the muon neutrino mass is anticipated. The experimental approach uses a high-intensity negative pion beam (produced at the PSI 590 MeV proton cyclotron), injected into a cyclotron trap and stopped inside a gas-filled target chamber, to form highly excited exotic atoms of pionic nitrogen and muonic oxygen. The energy of photons, emitted during de-excitation, is directly proportional to the mass of the pion or muon. These soft X-ray emission spectra are measured using a high-precision crystal spectrometer, with an array of six, high quantum efficiency X-ray position resolving CCDs at the focus. To achieve sub-ppm accuracy, simultaneous calibration of the pionic nitrogen line is provided by measurement of an adjacent muonic oxygen line, whose energy is known to 0.3 ppm. The high precision of the experiment offers a new opportunity to determine the pion mass to the leve...

  20. Method and apparatus for simultaneous determination of fluid mass flow rate, mean velocity and density

    International Nuclear Information System (INIS)

    Hamel, W.R.

    1984-01-01

    This invention relates to a new method and new apparatus for determining fluid mass flow rate and density. In one aspect of the invention, the fluid is passed through a straight cantilevered tube in which transient oscillation has been induced, thus generating Coriolis damping forces on the tube. The decay rate and frequency of the resulting damped oscillation are measured, and the fluid mass flow rate and density are determined therefrom. In another aspect of the invention, the fluid is passed through the cantilevered tube while an electrically powered device imparts steady-state harmonic excitation to the tube. This generates Coriolis tube-damping forces which are dependent on the mass flow rate of the fluid. Means are provided to respond to incipient flow-induced changes in the amplitude of vibration by changing the power input to the excitation device as required to sustain the original amplitude of vibration. The fluid mass flow rate and density are determined from the required change in power input. The invention provides stable, rapid, and accurate measurements. It does not require bending of the fluid flow

  1. Restoration of marine ecosystems following the end-Permian mass extinction: pattern and dynamics

    Science.gov (United States)

    Chen, Z.

    2013-12-01

    Life came closest to complete annihilation during the end-Permian mass extinction (EPME). Pattern and cause of this great dying have long been disputed. Similarly, there is also some debate on the recovery rate and pattern of marine organisms in the aftermath of the EPME. Some clades recovered rapidly, within the first 1-3 Myr of the Triassic. For instance, foraminiferal recovery began 1 Myr into the Triassic and was not much affected by Early Triassic crises. Further, some earliest Triassic body and trace fossil assemblages are also more diverse than predicted. Others, ie. Brachiopods, corals etc., however, did not rebound until the Middle Triassic. In addition, although ammonoids recovered fast, reaching a higher diversity by the Smithian than in the Late Permian, much of this Early Triassic radiation was within a single group, the Ceratitina, and their morphological disparity did not expand until the end-Spathian. Here, I like to broaden the modern ecologic network model to explore the complete trophic structure of fossilized ecosystems during the Permian-Triassic transition as a means of assessing the recovery. During the Late Permian and Early Triassic, primary producers, forming the lowest trophic level, were microbes. The middle part of the food web comprises primary and meso-consumer trophic levels, the former dominated by microorganisms such as foraminifers, the latter by opportunistic communities (i.e. disaster taxa), benthic shelly communities, and reef-builders. They were often consumed by invertebrate and vertebrate predators, the top trophic level. Fossil record from South China shows that the post-extinction ecosystems were degraded to a low level and typified by primary producers or opportunistic consumers, which are represented by widespread microbialites or high-abundance, low-diversity communities. Except for some opportunists, primary consumers, namely foraminifers, rebounded in Smithian. Trace-makers recovered in Spathian, which also saw

  2. Determination of molybdenum in plant reference material by thermal-ionization isotope-dilution mass spectrometry

    International Nuclear Information System (INIS)

    Saumer, M.; Gantner, E.; Reinhardt, J.; Ache, H.J.

    1992-01-01

    An analytical method is described for the determination of the concentration and the isotopic composition of molybdenum in plant samples using thermal ionization mass spectrometry. After microwave acid digestion and liquid-liquid extractive separation with Amberlite LA-2, the molybdenum isotopes are measured as MoO 3 - -ions in a quadrupole mass spectrometer. In all cases, the relative standard deviation of the measurements of both natural and spike molybdenum was better than 3% for all ratios measured. The concentration of molybdenum found in three different plant reference materials agreed well with the certified values. (orig.)

  3. Improved determination of the Higgs mass in the MSSM with heavy superpartners

    Energy Technology Data Exchange (ETDEWEB)

    Bagnaschi, Emanuele [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Pardo Vega, Javier [Abdus Salam International Centre for Theoretical Physics, Trieste (Italy); SISSA International School for Advanced Studies, Trieste (Italy); INFN, Trieste (Italy); Slavich, Pietro [UPMC Univ. Paris 06 Sorbonne Univs., Paris (France). LPTHE; CNRS, Paris (France). LPTHE

    2017-03-15

    We present several advances in the effective field theory calculation of the Higgs mass in MSSM scenarios with heavy superparticles. In particular, we compute the dominant two-loop threshold corrections to the quartic Higgs coupling for generic values of the relevant SUSY-breaking parameters, including all contributions controlled by the strong gauge coupling and by the third-family Yukawa couplings. We also study the effects of a representative subset of dimension-six operators in the effective theory valid below the SUSY scale. Our results will allow for an improved determination of the Higgs mass and of the associated theoretical uncertainty.

  4. Improved determination of the Higgs mass in the MSSM with heavy superpartners.

    Science.gov (United States)

    Bagnaschi, Emanuele; Vega, Javier Pardo; Slavich, Pietro

    2017-01-01

    We present several advances in the effective field theory calculation of the Higgs mass in MSSM scenarios with heavy superparticles. In particular, we compute the dominant two-loop threshold corrections to the quartic Higgs coupling for generic values of the relevant SUSY-breaking parameters, including all contributions controlled by the strong gauge coupling and by the third-family Yukawa couplings. We also study the effects of a representative subset of dimension-six operators in the effective theory valid below the SUSY scale. Our results will allow for an improved determination of the Higgs mass and of the associated theoretical uncertainty.

  5. Application of »Mass Titration« to Determination of Surface Charge of Metal Oxides

    OpenAIRE

    1998-01-01

    The mass titration method, used for the point of zero charge determination, was extended to the measurement of the surface charge density. The results agree with the common method, which is the acid-base titration of the colloidal suspension. The advantage of mass titration is that one does not need to perform blank titration, instead one simply adds metal oxide powder to the electrolyte aqueous solution of known pH. To cover the pH range above and below the point of zero charge, two experime...

  6. Controlling quark mass determinations non-perturbatively in three-flavour QCD

    CERN Document Server

    Campos, Isabel

    2017-01-01

    The determination of quark masses from lattice QCD simulations requires a non-perturbative renormalization procedure and subsequent scale evolution to high energies, where a conversion to the commonly used MS-bar scheme can be safely established. We present our results for the non-perturbative running of renormalized quark masses in Nf=3 QCD between the electroweak and a hadronic energy scale, where lattice simulations are at our disposal. Recent theoretical advances in combination with well-established techniques allows to follow the scale evolution to very high statistical accuracy, and full control of systematic effects.

  7. Improved determination of the Higgs mass in the MSSM with heavy superpartners

    Energy Technology Data Exchange (ETDEWEB)

    Bagnaschi, Emanuele [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Vega, Javier Pardo [Abdus Salam International Centre for Theoretical Physics, Trieste (Italy); SISSA International School for Advanced Studies, Trieste (Italy); INFN Trieste, Trieste (Italy); Slavich, Pietro [LPTHE, UPMC Univ. Paris 06, Sorbonne Universites, Paris (France); LPTHE, CNRS, Paris (France)

    2017-05-15

    We present several advances in the effective field theory calculation of the Higgs mass in MSSM scenarios with heavy superparticles. In particular, we compute the dominant two-loop threshold corrections to the quartic Higgs coupling for generic values of the relevant SUSY-breaking parameters, including all contributions controlled by the strong gauge coupling and by the third-family Yukawa couplings. We also study the effects of a representative subset of dimension-six operators in the effective theory valid below the SUSY scale. Our results will allow for an improved determination of the Higgs mass and of the associated theoretical uncertainty. (orig.)

  8. Standard addition strip for quantitative electrostatic spray ionization mass spectrometry analysis: determination of caffeine in drinks.

    Science.gov (United States)

    Tobolkina, Elena; Qiao, Liang; Roussel, Christophe; Girault, Hubert H

    2014-12-01

    Standard addition strips were prepared for the quantitative determination of caffeine in different beverages by electrostatic spray ionization mass spectrometry (ESTASI-MS). The gist of this approach is to dry spots of caffeine solutions with different concentrations on a polymer strip, then to deposit a drop of sample mixed with an internal standard, here theobromine on each spot and to measure the mass spectrometry signals of caffeine and theobromine by ESTASI-MS. This strip approach is very convenient and provides quantitative analyses as accurate as the classical standard addition method by MS or liquid chromatography. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Determination of Mg/Ca ratio of stalagmite by laser multicollector inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    He Xuexian; Zhu Xiangkun; Tang Suohan; Yang Chun; Cai Junjun; Li Shizhen; Li Zhihong

    2005-01-01

    A method for determining Mg/Ca of stalagmite by LA-MC-ICPMS is studied. 24 Mg/ 44 Ca (Mass 22, intensity of 44C a 2+ , collected by ion counting and mass 24, intensity of 24 Mg + , collected by Faraday cup) ratios were measured in replace of Mg/Ca ratios. Both diameter of laser sampling spot and laser moving increment were 2- μm. The curve of Mg/Ca vs. distance directly was obtained. The result indicates that relative Mg/Ca ratios changed from 0.5 to 2.0 this stalagmite and it is enough to reflect environmental factors act. (authors)

  10. Effects of 14-day oral low dose selenium nanoparticles and selenite in rat—as determined by metabolite pattern determination

    DEFF Research Database (Denmark)

    Hadrup, Niels; Löschner, Katrin; Skov, Kasper

    2016-01-01

    Selenium (Se) is an essential element with a small difference between physiological and toxic doses. To provide more effective and safe Se dosing regimens, as compared to dosing with ionic selenium, nanoparticle formulations have been developed. However, due to the nano-formulation, unexpected...... toxic effects may occur. We used metabolite pattern determination in urine to investigate biological and/or toxic effects in rats administered nanoparticles and for comparison included ionic selenium at an equimolar dose in the form of sodium selenite. Low doses of 10 and 100 fold the recommended human...

  11. Innovative application of the moisture analyzer for determination of dry mass content of processed cheese

    Science.gov (United States)

    Kowalska, Małgorzata; Janas, Sławomir; Woźniak, Magdalena

    2018-04-01

    The aim of this work was the presentation of an alternative method of determination of the total dry mass content in processed cheese. The authors claim that the presented method can be used in industry's quality control laboratories for routine testing and for quick in-process control. For the test purposes both reference method of determination of dry mass in processed cheese and moisture analyzer method were used. The tests were carried out for three different kinds of processed cheese. In accordance with the reference method, the sample was placed on a layer of silica sand and dried at the temperature of 102 °C for about 4 h. The moisture analyzer test required method validation, with regard to drying temperature range and mass of the analyzed sample. Optimum drying temperature of 110 °C was determined experimentally. For Hochland cream processed cheese sample, the total dry mass content, obtained using the reference method, was 38.92%, whereas using the moisture analyzer method, it was 38.74%. An average analysis time in case of the moisture analyzer method was 9 min. For the sample of processed cheese with tomatoes, the reference method result was 40.37%, and the alternative method result was 40.67%. For the sample of cream processed cheese with garlic the reference method gave value of 36.88%, and the alternative method, of 37.02%. An average time of those determinations was 16 min. Obtained results confirmed that use of moisture analyzer is effective. Compliant values of dry mass content were obtained for both of the used methods. According to the authors, the fact that the measurement took incomparably less time for moisture analyzer method, is a key criterion of in-process control and final quality control method selection.

  12. Real-time determination of fringe pattern frequencies: An application to pressure measurement

    Science.gov (United States)

    Sciammarella, Cesar A.; Piroozan, Parham

    2007-05-01

    Retrieving information in real time from fringe patterns is a topic of a great deal of interest in scientific and engineering applications of optical methods. This paper presents a method for fringe frequency determination based on the capability of neural networks to recognize signals that are similar but not identical to signals used to train the neural network. Sampled patterns are generated by calibration and stored in memory. Incoming patterns are analyzed by a back-propagation neural network at the speed of the recording device, a CCD camera. This method of information retrieval is utilized to measure pressures on a boundary layer flow. The sensor combines optics and electronics to analyze dynamic pressure distributions and to feed information to a control system that is capable to preserve the stability of the flow.

  13. Spatial patterns of North Atlantic Oscillation influence on mass balance variability of European glaciers

    Directory of Open Access Journals (Sweden)

    B. Marzeion

    2012-06-01

    Full Text Available We present and validate a set of minimal models of glacier mass balance variability. The most skillful model is then applied to reconstruct 7735 individual time series of mass balance variability for all glaciers in the European Alps and Scandinavia. Subsequently, we investigate the influence of atmospheric variability associated with the North Atlantic Oscillation (NAO on the glaciers' mass balances.

    We find a spatial coherence in the glaciers' sensitivity to NAO forcing which is caused by regionally similar mechanisms relating the NAO forcing to the mass balance: in southwestern Scandinavia, winter precipitation causes a correlation of mass balances with the NAO. In northern Scandinavia, temperature anomalies outside the core winter season cause an anti-correlation between NAO and mass balances. In the western Alps, both temperature and winter precipitation anomalies lead to a weak anti-correlation of mass balances with the NAO, while in the eastern Alps, the influences of winter precipitation and temperature anomalies tend to cancel each other, and only on the southern side a slight anti-correlation of mass balances with the NAO prevails.

  14. Mass detection, localization and estimation for wind turbine blades based on statistical pattern recognition

    DEFF Research Database (Denmark)

    Colone, L.; Hovgaard, K.; Glavind, Lars

    2018-01-01

    A method for mass change detection on wind turbine blades using natural frequencies is presented. The approach is based on two statistical tests. The first test decides if there is a significant mass change and the second test is a statistical group classification based on Linear Discriminant Ana...

  15. An assessment of anti-neutrino mass determination via electrostatic measurements of tritium beta-decay

    International Nuclear Information System (INIS)

    Le Bas, P.A.

    1984-01-01

    Data on the mass of the anti-neutrino determined via electrostatic measurements of tritium beta-decay are assessed. Relativistic calculations concerning the finite mass of the electron anti-neutrino and the recoil of the nucleus, are given for the theoretical end-point spectrum of tritium beta-decay. The specifications are given for an electrostatic Spherical Retarding Beta-Spectrometer, and an electrostatic Cylindrical Mirror Analyser, both used in the tritium beta-decay experiment. The electrostatic measurements lead to a value of less than 50 ev (90% C.L.) for the electron anti-neutrino mass. These results are discussed in terms of the resolution of the electrostatic equipment and the Monte Carlo simulations of the data collection. (UK)

  16. A LEGO Watt balance: An apparatus to determine a mass based on the new SI

    Science.gov (United States)

    Chao, L. S.; Schlamminger, S.; Newell, D. B.; Pratt, J. R.; Seifert, F.; Zhang, X.; Sineriz, G.; Liu, M.; Haddad, D.

    2015-11-01

    A global effort to redefine our International System of Units (SI) is underway, and the change to the new system is expected to occur in 2018. Within the newly redefined SI, the present base units will still exist but be derived from fixed numerical values of seven reference constants. In particular, the unit of mass (the kilogram) will be realized through a fixed value of the Planck constant h. A so-called watt balance, for example, can then be used to realize the kilogram unit of mass within a few parts in 108. Such a balance has been designed and constructed at the National Institute of Standards and Technology. For educational outreach and to demonstrate the principle, we have constructed a LEGO tabletop watt balance capable of measuring a gram-level masses to 1% relative uncertainty. This article presents the design, construction, and performance of the LEGO watt balance and its ability to determine h.

  17. Total cholesterol in serum determined by isotope dilution/mass spectrometry, with liquid-chromatographic separation

    International Nuclear Information System (INIS)

    Takatsu, Akiko; Nishi, Sueo

    1988-01-01

    We describe an accurate, precise method for determination of total serum cholesterol by isotope dilution/mass spectrometry (IDMS) with liquid chromatographic separation. After adding [3,4- 13 C] cholesterol to serum and hydrolyzing the cholesterol esters, we extract the total cholesterol. High-performance liquid chromatography (HPLC) is used to separate the extracted cholesterol for measurement by electron-impact mass spectrometry with use of a direct-insertion device. To evaluate the specificity and the accuracy of this method, we also studied the conventional IDMS method, which involves converting cholesterol to the trimethylsilyl ether and assay by gas chromatography-mass spectrometry with use of a capillary column. The coefficient of variation for the HPLC method was a little larger than for the conventional method, but mean values by each method agreed within 1% for all sera tested. (author)

  18. REFINED NEUTRON STAR MASS DETERMINATIONS FOR SIX ECLIPSING X-RAY PULSAR BINARIES

    International Nuclear Information System (INIS)

    Rawls, Meredith L.; Orosz, Jerome A.; McClintock, Jeffrey E.; Torres, Manuel A. P.; Bailyn, Charles D.; Buxton, Michelle M.

    2011-01-01

    We present an improved method for determining the mass of neutron stars in eclipsing X-ray pulsar binaries and apply the method to six systems, namely, Vela X-1, 4U 1538-52, SMC X-1, LMC X-4, Cen X-3, and Her X-1. In previous studies to determine neutron star mass, the X-ray eclipse duration has been approximated analytically by assuming that the companion star is spherical with an effective Roche lobe radius. We use a numerical code based on Roche geometry with various optimizers to analyze the published data for these systems, which we supplement with new spectroscopic and photometric data for 4U 1538-52. This allows us to model the eclipse duration more accurately and thus calculate an improved value for the neutron star mass. The derived neutron star mass also depends on the assumed Roche lobe filling factor β of the companion star, where β = 1 indicates a completely filled Roche lobe. In previous work a range of β between 0.9 and 1.0 was usually adopted. We use optical ellipsoidal light-curve data to constrain β. We find neutron star masses of 1.77 ± 0.08 M sun for Vela X-1, 0.87 ± 0.07 M sun for 4U 1538-52 (eccentric orbit), 1.00 ± 0.10 M sun for 4U 1538-52 (circular orbit), 1.04 ± 0.09 M sun for SMC X-1, 1.29 ± 0.05 M sun for LMC X-4, 1.49 ± 0.08 M sun for Cen X-3, and 1.07 ± 0.36 M sun for Her X-1. We discuss the limits of the approximations that were used to derive the earlier mass determinations, and we comment on the implications our new masses have for observationally refining the upper and lower bounds of the neutron star mass distribution.

  19. Determining the neutrino mass hierarchy with INO, T2K, NOvA and reactor experiments

    International Nuclear Information System (INIS)

    Ghosh, Anushree; Choubey, Sandhya; Thakore, Tarak

    2013-01-01

    The relatively large measured value of θ 13 has opened up the possibility of determining the neutrino mass hierarchy through earth matter effects. Amongst the current accelerator experiments only NOvA has a long enough baseline to observe earth matter effects. However, even NOvA is plagued with uncertainty on the knowledge of the true value of Δ CP which drastically reduces its sensitivity to the neutrino mass hierarchy. Earth matter effects in atmospheric neutrinos on the other hand is almost independent of δ CP . The 50 kton magnetized Iron CALorimeter at the India-based Neutrino Observatory (ICAL at the rate lNO) will be observing atmospheric neutrinos. The charge identification capability of this detector gives it an edge over others for mass hierarchy determination through observation of earth matter effects. We study in detail the neutrino mass hierarchy sensitivity of the data from this experiment simulated using the Nuance based generator developed for ICAL at the rate lNO and folded with the detector resolution and efficiencies obtained by the INO collaboration from a full detector Geant based simulation. The data from ICAL at the rate lNO is then combined with simulated of T2K, NOvA Double Chooz, RENO and Daya Bay experiments and a combined sensitivity study to the mass hierarchy performed. With 10 years of ICAL at the rate lNO data combined with T2K, NOvA and reactor data, one could get 2.8σ - 5σ discovery for the neutrino mass hierarchy depending on the true value of (θ23, θ13 and δ CP . (author)

  20. Determination of long-lived actinides in soil leachates by inductively coupled plasma: Mass spectrometry

    International Nuclear Information System (INIS)

    Crain, J.S.; Smith, L.L.; Yaeger, J.S.; Alvarado, J.A.

    1994-01-01

    Inductively coupled plasma -- mass spectrometry (ICP-MS) was used to concurrently determine multiple long-lived (t 1/2 > 10 4 y) actinide isotopes in soil samples. Ultrasonic nebulization was found to maximize instrument sensitivity. Instrument detection limits for actinides in solution ranged from 50 mBq L -1 ( 239 Pu) to 2 μBq L -1 ( 235 U) Hydride adducts of 232 Th and 238 U interfered with the determinations of 233 U and 239 Pu; thus, extraction chromatography was, used to eliminate the sample matrix, concentrate the analytes, and separate uranium from the other actinides. Alpha spectrometric determinations of 230 Th, 239 Pu, and the 234 U/ 238 U activity ratio in soil leachates compared well with ICP-MS determinations; however, there were some small systematic differences (ca. 10%) between ICP-MS and a-spectrometric determinations of 234 U and 238 U activities

  1. Chronic hypersensitivity pneumonitis: high resolution computed tomography patterns and pulmonary function indices as prognostic determinants

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Simon L.F.; Devaraj, Anand; Hansell, David M. [Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Sverzellati, Nicola [University of Parma, Department of Clinical Sciences, Section of Radiology, Parma (Italy); Wells, Athol U. [Royal Brompton Hospital, Interstitial Lung Diseases Unit, London (United Kingdom)

    2012-08-15

    To investigate high resolution computed tomography (HRCT) and pulmonary function indices (PFTs) for determining prognosis in patients with chronic fibrotic hypersensitivity pneumonitis (CHP). Case records, PFTs (FEV{sub 1}, FVC and DLco) and HRCTs of ninety-two patients with chronic hypersensitivity pneumonitis were evaluated. HRCT studies were scored by two observers for total disease extent, ground-glass opacification, fine and coarse reticulation, microcystic and macrocystic honeycombing, centrilobular emphysema and consolidation. Traction bronchiectasis within each pattern was graded. Using Cox proportional hazards regression models the prognostic strength of individual HRCT patterns and pulmonary function test variables were determined. There were forty two deaths during the study period. Increasing severity of traction bronchiectasis was the strongest predictor of mortality (HR 1.10, P < 0.001, 95%CI 1.04-1.16). Increasing global interstitial disease extent (HR 1.02, P = 0.02, 95%CI 1.00-1.03), microcystic honeycombing (HR 1.09, P = 0.019, 95%CI 1.01-1.17) and macrocystic honeycombing (HR 1.06, P < 0.01, 95%CI 1.01-1.10) were also independent predictors of mortality. In contrast, no individual PFT variable was predictive of mortality once HRCT patterns were accounted for. HRCT patterns, in particular, severity of traction bronchiectasis and extent of honeycombing are superior to pulmonary function tests for predicting mortality in patients with CHP. (orig.)

  2. Chronic hypersensitivity pneumonitis: high resolution computed tomography patterns and pulmonary function indices as prognostic determinants

    International Nuclear Information System (INIS)

    Walsh, Simon L.F.; Devaraj, Anand; Hansell, David M.; Sverzellati, Nicola; Wells, Athol U.

    2012-01-01

    To investigate high resolution computed tomography (HRCT) and pulmonary function indices (PFTs) for determining prognosis in patients with chronic fibrotic hypersensitivity pneumonitis (CHP). Case records, PFTs (FEV 1 , FVC and DLco) and HRCTs of ninety-two patients with chronic hypersensitivity pneumonitis were evaluated. HRCT studies were scored by two observers for total disease extent, ground-glass opacification, fine and coarse reticulation, microcystic and macrocystic honeycombing, centrilobular emphysema and consolidation. Traction bronchiectasis within each pattern was graded. Using Cox proportional hazards regression models the prognostic strength of individual HRCT patterns and pulmonary function test variables were determined. There were forty two deaths during the study period. Increasing severity of traction bronchiectasis was the strongest predictor of mortality (HR 1.10, P < 0.001, 95%CI 1.04-1.16). Increasing global interstitial disease extent (HR 1.02, P = 0.02, 95%CI 1.00-1.03), microcystic honeycombing (HR 1.09, P = 0.019, 95%CI 1.01-1.17) and macrocystic honeycombing (HR 1.06, P < 0.01, 95%CI 1.01-1.10) were also independent predictors of mortality. In contrast, no individual PFT variable was predictive of mortality once HRCT patterns were accounted for. HRCT patterns, in particular, severity of traction bronchiectasis and extent of honeycombing are superior to pulmonary function tests for predicting mortality in patients with CHP. (orig.)

  3. Determination of traffic intensity from camera images using image processing and pattern recognition techniques

    Science.gov (United States)

    Mehrübeoğlu, Mehrübe; McLauchlan, Lifford

    2006-02-01

    The goal of this project was to detect the intensity of traffic on a road at different times of the day during daytime. Although the work presented utilized images from a section of a highway, the results of this project are intended for making decisions on the type of intervention necessary on any given road at different times for traffic control, such as installation of traffic signals, duration of red, green and yellow lights at intersections, and assignment of traffic control officers near school zones or other relevant locations. In this project, directional patterns are used to detect and count the number of cars in traffic images over a fixed area of the road to determine local traffic intensity. Directional patterns are chosen because they are simple and common to almost all moving vehicles. Perspective vision effects specific to each camera orientation has to be considered, as they affect the size and direction of patterns to be recognized. In this work, a simple and fast algorithm has been developed based on horizontal directional pattern matching and perspective vision adjustment. The results of the algorithm under various conditions are presented and compared in this paper. Using the developed algorithm, the traffic intensity can accurately be determined on clear days with average sized cars. The accuracy is reduced on rainy days when the camera lens contains raindrops, when there are very long vehicles, such as trucks or tankers, in the view, and when there is very low light around dusk or dawn.

  4. Role of Dietary Pattern Analysis in Determining Cognitive Status in Elderly Australian Adults

    Directory of Open Access Journals (Sweden)

    Kimberly Ashby-Mitchell

    2015-02-01

    Full Text Available Principal Component Analysis (PCA was used to determine the association between dietary patterns and cognitive function and to examine how classification systems based on food groups and food items affect levels of association between diet and cognitive function. The present study focuses on the older segment of the Australian Diabetes, Obesity and Lifestyle Study (AusDiab sample (age 60+ that completed the food frequency questionnaire at Wave 1 (1999/2000 and the mini-mental state examination and tests of memory, verbal ability and processing speed at Wave 3 (2012. Three methods were used in order to classify these foods before applying PCA. In the first instance, the 101 individual food items asked about in the questionnaire were used (no categorisation. In the second and third instances, foods were combined and reduced to 32 and 20 food groups, respectively, based on nutrient content and culinary usage—a method employed in several other published studies for PCA. Logistic regression analysis and generalized linear modelling was used to analyse the relationship between PCA-derived dietary patterns and cognitive outcome. Broader food group classifications resulted in a greater proportion of food use variance in the sample being explained (use of 101 individual foods explained 23.22% of total food use, while use of 32 and 20 food groups explained 29.74% and 30.74% of total variance in food use in the sample, respectively. Three dietary patterns were found to be associated with decreased odds of cognitive impairment (CI. Dietary patterns derived from 101 individual food items showed that for every one unit increase in ((Fruit and Vegetable Pattern: p = 0.030, OR 1.061, confidence interval: 1.006–1.118; (Fish, Legumes and Vegetable Pattern: p = 0.040, OR 1.032, confidence interval: 1.001–1.064; (Dairy, Cereal and Eggs Pattern: p = 0.003, OR 1.020, confidence interval: 1.007–1.033, the odds of cognitive impairment decreased. Different

  5. Real time determination of the laser ablated mass by means of electric field-perturbation measurement

    Science.gov (United States)

    Pacheco, P.; Álvarez, J.; Sarmiento, R.; Bredice, F.; Sánchez-Aké, C.; Villagrán-Muniz, M.; Palleschi, V.

    2018-04-01

    A Nd:YAG ns-pulsed laser was used to ablate Al, Cd and Zn targets, which were placed between the plates of a planar charged capacitor. The plasma generates a transient redistribution of the electrical charges on the plates that can be measured as a voltage drop across a resistor connected to the ground plate. This signal is proportional to the capacitor applied voltage, the distance between the plates and the total number of ions produced in the ablation process which in turn is related to the laser energy and the ablated mass. After a series of pulses, the targets were weighed on a thermogravimetric balance to measure the ablated mass. Our results show that the electrical signal measured on the resistor is univocally related to the ablated mass from the target. Therefore, after a proper calibration depending on the material and the experimental geometry, the electrical signal can be used for real time quantitative measurement of the ablated mass in pulsed laser generated plasma experiments. The experiments were repeated on an aluminum target, with and without the presence of the external electric field in order to determine the possible influence of the applied electric field on the ablated mass.

  6. Determination of the neutron mass; Determinacion de la masa del neutron

    Energy Technology Data Exchange (ETDEWEB)

    Amador V, P.; Chacon R, A.; Arcos P, A.; Rodriguez N, S.; Pinedo S, A.; Vega C, H.R. [Unidad Academica de Estudios Nucleares, Cipres 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)]. e-mail: paus2281@yahoo.com.mx

    2005-07-01

    The binding energy of the deuteron was measured and it was determined the neutron mass starting from the nuclear reaction, {sup 1}{sub 0} n + {sup 1}{sub 1} H {yields}{sup 2}{sub 1} D + {gamma}. The produced photon is soon a gamma ray that is emitted when the hydrogen captures a thermal neutron. The photon energy was measured using two spectrometric systems for gamma rays. A system with a detector of NaI(TI) of 3'' x 3'' and the other one with a High-purity Germanium detector. The first detector has a bigger efficiency and a smaller resolution in comparison with the second detector. The energy of the measured photon is the binding energy of the deuteron. With the measurement of the photon energy and the masses of the proton and of the deuterium it was determined the neutron mass. The value of the mass obtained with both systems it was compared with the value reported in the literature. The nuclear reaction was induced in a volume of paraffin that it was bombing with a source {sup 239} PuBe whose activity is of 3.7 x 10{sup 10} Bq. (Author)

  7. Chiral recognition and determination of enantiomeric excess by mass spectrometry: A review

    International Nuclear Information System (INIS)

    Yu, Xiangying; Yao, Zhong-Ping

    2017-01-01

    Chiral analysis is of great importance to fundamental and applied research in chemical, biological and pharmaceutical sciences. Due to the superiority of mass spectrometry (MS) over other analytical methods in terms of speed, specificity and sensitivity, chiral analysis by MS has attracted much interest in recent years. Chiral analysis by MS typically involves introduction of a chiral selector to form diastereomers with analyte enantiomers, and comparison of the behaviors of diastereomers in MS. Chiral differentiation can be achieved by comparing the relative abundances of diastereomers, the thermodynamic or kinetic constants of ion-molecule reactions of diastereomers in the gas phase, the dissociation of diastereomers in MS/MS, or the mobility of diastereomers in ion mobility mass spectrometry. In this review, chiral recognition and determination of enantiomeric excess by these chiral MS methods were summarized, and the prospects of chiral analysis by MS were discussed. - Highlights: • Both chiral recognition and determination of enantiomeric excess by mass spectrometry are systematically reviewed. • Classification is based on the behavioral differences of diastereomers formed between chiral analytes and chiral selectors. • Development of ion mobility mass spectrometry for chiral differentiation is covered. • Various methods are highlighted and compared.

  8. REVISITING ρ1 CANCRI e: A NEW MASS DETERMINATION OF THE TRANSITING SUPER-EARTH

    International Nuclear Information System (INIS)

    Endl, Michael; Cochran, William D.; MacQueen, Phillip J.; Barnes, Stuart I.; Robertson, Paul; Brugamyer, Erik J.; Caldwell, Caroline; Gullikson, Kevin; Wittenmyer, Robert A.

    2012-01-01

    We present a mass determination for the transiting super-Earth ρ 1 Cancri e based on nearly 700 precise radial velocity (RV) measurements. This extensive RV data set consists of data collected by the McDonald Observatory planet search and published data from Lick and Keck observatories. We obtained 212 RV measurements with the Tull Coudé Spectrograph at the Harlan J. Smith 2.7 m Telescope and combined them with a new Doppler reduction of the 131 spectra that we have taken in 2003-2004 with the High-Resolution Spectrograph (HRS) at the Hobby-Eberly Telescope for the original discovery of ρ 1 Cancri e. Using this large data set we obtain a five-planet Keplerian orbital solution for the system and measure an RV semi-amplitude of K = 6.29 ± 0.21 m s –1 for ρ 1 Cnc e and determine a mass of 8.37 ± 0.38 M ⊕ . The uncertainty in mass is thus less than 5%. This planet was previously found to transit its parent star, which allowed them to estimate its radius. Combined with the latest radius estimate from Gillon et al., we obtain a mean density of ρ = 4.50 ± 0.20 g cm –3 . The location of ρ 1 Cnc e in the mass-radius diagram suggests that the planet contains a significant amount of volatiles, possibly a water-rich envelope surrounding a rocky core.

  9. Chiral recognition and determination of enantiomeric excess by mass spectrometry: A review

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Xiangying [College of Pharmacy, Jinan University, Guangzhou 510632, Guangdong (China); State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation) and Shenzhen Key Laboratory of Food Biological Safety Control, Shenzhen Research Institute of Hong Kong Polytechnic University, Shenzhen 518057 (China); Yao, Zhong-Ping, E-mail: zhongping.yao@polyu.edu.hk [State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation) and Shenzhen Key Laboratory of Food Biological Safety Control, Shenzhen Research Institute of Hong Kong Polytechnic University, Shenzhen 518057 (China); Key Laboratory of Natural Resources of Changbai Mountain and Functional Molecules (Yanbian University), Ministry of Education, Yanji 133002, Jilin (China); State Key Laboratory of Chirosciences, Food Safety and Technology Research Centre and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region (China)

    2017-05-22

    Chiral analysis is of great importance to fundamental and applied research in chemical, biological and pharmaceutical sciences. Due to the superiority of mass spectrometry (MS) over other analytical methods in terms of speed, specificity and sensitivity, chiral analysis by MS has attracted much interest in recent years. Chiral analysis by MS typically involves introduction of a chiral selector to form diastereomers with analyte enantiomers, and comparison of the behaviors of diastereomers in MS. Chiral differentiation can be achieved by comparing the relative abundances of diastereomers, the thermodynamic or kinetic constants of ion-molecule reactions of diastereomers in the gas phase, the dissociation of diastereomers in MS/MS, or the mobility of diastereomers in ion mobility mass spectrometry. In this review, chiral recognition and determination of enantiomeric excess by these chiral MS methods were summarized, and the prospects of chiral analysis by MS were discussed. - Highlights: • Both chiral recognition and determination of enantiomeric excess by mass spectrometry are systematically reviewed. • Classification is based on the behavioral differences of diastereomers formed between chiral analytes and chiral selectors. • Development of ion mobility mass spectrometry for chiral differentiation is covered. • Various methods are highlighted and compared.

  10. Determining the REV for Fracture Rock Mass Based on Seepage Theory

    Directory of Open Access Journals (Sweden)

    Lili Zhang

    2017-01-01

    Full Text Available Seepage problems of the fractured rock mass have always been a heated topic within hydrogeology and engineering geology. The equivalent porous medium model method is the main method in the study of the seepage of the fractured rock mass and its engineering application. The key to the method is to determine a representative elementary volume (REV. The FractureToKarst software, that is, discrete element software, is a main analysis tool in this paper and developed by a number of authors. According to the standard of rock classification established by ISRM, this paper aims to discuss the existence and the size of REV of fractured rock masses with medium tractility and provide a general method to determine the existence of REV. It can be gleaned from the study that the existence condition of fractured rock mass with medium tractility features average fracture spacing smaller than 0.6 m. If average fracture spacing is larger than 0.6 m, there is no existence of REV. The rationality of the model is verified by a case study. The present research provides a method for the simulation of seepage field in fissured rocks.

  11. Spatiotemporal Patterns of Ice Mass Variations and the Local Climatic Factors in the Riparian Zone of Central Valley, California

    Science.gov (United States)

    Inamdar, P.; Ambinakudige, S.

    2016-12-01

    Californian icefields are natural basins of fresh water. They provide irrigation water to the farms in the central valley. We analyzed the ice mass loss rates, air temperature and land surface temperature (LST) in Sacramento and San Joaquin basins in California. The digital elevation models from Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) were used to calculate ice mass loss rate between the years 2002 and 2015. Additionally, Landsat TIR data were used to extract the land surface temperature. Data from local weather stations were analyzed to understand the spatiotemporal trends in air temperature. The results showed an overall mass recession of -0.8 ± 0.7 m w.e.a-1. We also noticed an about 60% loss in areal extent of the glaciers in the study basins between 2000 and 2015. Local climatic factors, along with the global climate patterns might have influenced the negative trends in the ice mass loss. Overall, there was an increase in the air temperature by 0.07± 0.02 °C in the central valley between 2000 and 2015. Furthermore, LST increased by 0.34 ± 0.4 °C and 0.55± 0.1 °C in the Sacramento and San Joaquin basins. Our preliminary results show the decrease in area and mass of ice mass in the basins, and changing agricultural practices in the valley.

  12. Automated system for the determination of patterns of high-intensity LEDs

    International Nuclear Information System (INIS)

    Baly, L.; Bolaño, L.; Arteche, R.; Broco, Y.; Quesada, I.; Rodríguez, E.

    2008-01-01

    Determination of high-intensity LEDs lighting patterns is an important step for the simulation and planning of arrays of these devices configurations. Currently there are systems based on CCD cameras able to efficiently solve this problem, however the high cost of these is a limiting factor for use. Another limitation of CCD cameras, is that they are designed for light levels much lower than those produced by a high-intensity LED. In this paper we present an automated system for the determination of the intensity of LEDs based on the scan point to point patterns. The results of the analysis of a type of LED based on arrays of bars with built-in optical system is presented.

  13. Determination of neutrino mass hierarchy and θ13 with a remote detector of reactor antineutrinos

    International Nuclear Information System (INIS)

    Learned, John G.; Pakvasa, Sandip; Dye, Stephen T.; Svoboda, Robert C.

    2008-01-01

    We describe a method for determining the hierarchy of the neutrino mass spectrum and θ 13 through remote detection of electron antineutrinos from a nuclear reactor. This method utilizing a single, 10-kiloton scintillating liquid detector at a distance of 49-63 kilometers from the reactor complex measures mass-squared differences involving ν 3 with a one(ten)-year exposure provided sin 2 (2θ 13 )>0.05(0.02). Our technique applies the Fourier transform to the event rate as a function of neutrino flight distance over neutrino energy. Sweeping a relevant range of δm 2 resolves separate spectral peaks for δm 2 31 and δm 2 32 . For normal (inverted) hierarchy |δm 2 31 | is greater (lesser) than |δm 2 32 |. This robust determination requires a detector energy resolution of 3.5%/√(E).

  14. Penning trap mass spectrometry Q-value determinations for highly forbidden β-decays

    Science.gov (United States)

    Sandler, Rachel; Bollen, Georg; Eibach, Martin; Gamage, Nadeesha; Gulyuz, Kerim; Hamaker, Alec; Izzo, Chris; Kandegedara, Rathnayake; Redshaw, Matt; Ringle, Ryan; Valverde, Adrian; Yandow, Isaac; Low Energy Beam Ion Trap Team

    2017-09-01

    Over the last several decades, extremely sensitive, ultra-low background beta and gamma detection techniques have been developed. These techniques have enabled the observation of very rare processes, such as highly forbidden beta decays e.g. of 113Cd, 50V and 138La. Half-life measurements of highly forbidden beta decays provide a testing ground for theoretical nuclear models, and the comparison of calculated and measured energy spectra could enable a determination of the values of the weak coupling constants. Precision Q-value measurements also allow for systematic tests of the beta-particle detection techniques. We will present the results and current status of Q value determinations for highly forbidden beta decays. The Q values, the mass difference between parent and daughter nuclides, are measured using the high precision Penning trap mass spectrometer LEBIT at the National Superconducting Cyclotron Laboratory.

  15. Model-independent determination of the WIMP mass from direct dark matter detection data

    International Nuclear Information System (INIS)

    Drees, Manuel; Shan, Chung-Lin

    2008-01-01

    Weakly interacting massive particles (WIMPs) are one of the leading candidates for dark matter. We develop a model-independent method for determining the mass m χ of the WIMP by using data (i.e. measured recoil energies) of direct detection experiments. Our method is independent of the as yet unknown WIMP density near the Earth, of the form of the WIMP velocity distribution, as well as of the WIMP–nucleus cross section. However, it requires positive signals from at least two detectors with different target nuclei. In a background-free environment, m χ ∼50 GeV could in principle be determined with an error of ∼35% with only 2 × 50 events; in practice, upper and lower limits on the recoil energy of signal events, imposed to reduce backgrounds, can increase the error. The method also loses precision if m χ significantly exceeds the mass of the heaviest target nucleus used

  16. Prospects for asteroid mass determination from close encounters between asteroids: ESA's Gaia space mission and beyond

    Science.gov (United States)

    Ivantsov, Anatoliy; Hestroffer, Daniel; Eggl, Siegfried

    2018-04-01

    We present a catalog of potential candidates for asteroid mass determination based on mutual close encounters of numbered asteroids with massive perturbers (D>20 km). Using a novel geometric approach tuned to optimize observability, we predict optimal epochs for mass determination observations. In contrast to previous studies that often used simplified dynamical models, we have numerically propagated the trajectories of all numbered asteroids over the time interval from 2013 to 2023 using relativistic equations of motion including planetary perturbations, J2 of the Sun, the 16 major asteroid perturbers and the perturbations due to non-sphericities of the planets. We compiled a catalog of close encounters between asteroids where the observable perturbation of the sky plane trajectory is greater than 0.5 mas so that astrometric measurements of the perturbed asteroids in the Gaia data can be leveraged. The catalog v1.0 is available at ftp://dosya.akdeniz.edu.tr/ivantsov.

  17. Determination of void fraction from source range monitor and mass flow rate data

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1986-09-01

    This is a report on the calculation of the TMI-2 primary coolant system local void fraction from source range neutron flux monitor data and from hot leg mass flowrate meter data during the first 100 minutes of the accident. The methods of calculation of void fraction from the two data sources is explained and the results are compared. It is indicated that the void fraction determined using the mass flowrate data contained an error of unknown magnitude due to the assumption of constant homogeneous volumetric flowrate used in the calculation and required further work. Void fraction determined from the source range monitor data is felt to be usable although an uncertainty analysis has not been performed

  18. Determining picogram quantities of U in human urine by thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Kelly, W.R.; Fassett, J.D.; Hotes, S.A.

    1987-01-01

    The U concentration in Standard Reference Material 2670 (Toxic Metals in Freeze-Dried Urine) and the urine of two preschool-age children were determined by measuring the chemically separated U by isotope dilution thermal ionization mass spectrometry using ion counting detection. This procedure can detect about 1% of the U atoms loaded into the mass spectrometer and has a total chemical blank of about 5 pg U. The U concentration in SRM 2670 was found to be 113 +/- 2 pg 238 U/ml (1 s). At this concentration, a 1-ml sample is sufficient for a determination with a total uncertainty of less than 5%. The U concentrations in the two children were 3.1 +/- 0.9 and 3.6 +/- 0.9 pg 238 U/g. These values suggest that the U concentration in urine of unexposed persons may be at this low level or lower

  19. Determinants of Heterogeneous Blood Feeding Patterns by Aedes aegypti in Iquitos, Peru

    OpenAIRE

    Liebman, Kelly A.; Stoddard, Steven T.; Reiner, Robert C.; Perkins, T. Alex; Astete, Helvio; Sihuincha, Moises; Halsey, Eric S.; Kochel, Tadeusz J.; Morrison, Amy C.; Scott, Thomas W.

    2014-01-01

    Background Heterogeneous mosquito biting results in different individuals in a population receiving an uneven number of bites. This is a feature of many vector-borne disease systems that, if understood, could guide preventative control efforts toward individuals who are expected to contribute most to pathogen transmission. We aimed to characterize factors determining biting patterns of Aedes aegypti, the principal mosquito vector of dengue virus. Methodology/Principal Findings Engorged female...

  20. Determination of drift-flux velocity as a function of two-phase flow patterns

    International Nuclear Information System (INIS)

    Austregesilo Filho, H.

    1986-01-01

    A method is suggested for the calculation of drift-flux velocity as a function of two-phase flow patterns determined analytically. This model can be introduced in computer codes for thermal hydraulic analyses based mainly on homogeneous assumptions, in order to achieve a more realis tic description of two-phase flow phenomena, which is needed for the simulation of accidents in nuclear power plants for which phase separation effects are dominant, e.g., small break accidents. (Author) [pt

  1. Multi-resolution analysis using integrated microscopic configuration with local patterns for benign-malignant mass classification

    Science.gov (United States)

    Rabidas, Rinku; Midya, Abhishek; Chakraborty, Jayasree; Sadhu, Anup; Arif, Wasim

    2018-02-01

    In this paper, Curvelet based local attributes, Curvelet-Local configuration pattern (C-LCP), is introduced for the characterization of mammographic masses as benign or malignant. Amid different anomalies such as micro- calcification, bilateral asymmetry, architectural distortion, and masses, the reason for targeting the mass lesions is due to their variation in shape, size, and margin which makes the diagnosis a challenging task. Being efficient in classification, multi-resolution property of the Curvelet transform is exploited and local information is extracted from the coefficients of each subband using Local configuration pattern (LCP). The microscopic measures in concatenation with the local textural information provide more discriminating capability than individual. The measures embody the magnitude information along with the pixel-wise relationships among the neighboring pixels. The performance analysis is conducted with 200 mammograms of the DDSM database containing 100 mass cases of each benign and malignant. The optimal set of features is acquired via stepwise logistic regression method and the classification is carried out with Fisher linear discriminant analysis. The best area under the receiver operating characteristic curve and accuracy of 0.95 and 87.55% are achieved with the proposed method, which is further compared with some of the state-of-the-art competing methods.

  2. Determination of Rock Mass Modulus Using the Plate Loading Method at Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Finley, R.E.; George, J.T.; Riggins, M.

    1999-01-01

    A suite of plate loading tests has recently been conducted by Sandia National Laboratories at the Exploratory Studies Facility at Yucca Mountain, Nevada. Fielding of these in situ tests as well as other approaches undertaken for the determination of rock mass modulus are described. The various methodologies are evaluated and their data compared. Calculation by existing empirical methods and numerical modeling are compared to each other as well as to field data

  3. Determination of ketone bodies in blood by headspace gas chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Holm, Karen Marie Dollerup; Linnet, Kristian; Rasmussen, Brian Schou

    2010-01-01

    A gas chromatography-mass spectrometry (GC-MS) method for determination of ketone bodies (ß-hydroxybutyrate, acetone, and acetoacetate) in blood is presented. The method is based on enzymatic oxidation of D-ß-hydroxybutyrate to acetoacetate, followed by decarboxylation to acetone, which...... was quantified by the use of headspace GC-MS using acetone-(13)C(3) as an internal standard. The developed method was found to have intra- and total interday relative standard deviations

  4. Classification of wine by determination of bioactive phenolic compounds using high resolution mass spectrometry

    OpenAIRE

    Ivanova, Violeta; Dimovska, Violeta; Mitrev, Sasa; Gulaboski, Rubin; Bogeva, Elena; Petruseva, Dragana; Causon, Tim; Hann, Stephan

    2016-01-01

    In this project proposal, metabolomic fingerprinting of wine samples will be examined using high performance liquid chromatography combined with ion mobility quadruple time-of-flight mass spectrometry (HPLC–IMS-QTOF-MS) for the first time. Bioactive compounds in wines from various red and white varieties produced in Macedonia and Austria from different wine regions and different vintages will be determined for the first time using a non-targeted fingerprinting approach on this analytical plat...

  5. Determination of thorium in seawater by neutron activation analysis and mass spectrometry

    International Nuclear Information System (INIS)

    Huh, Chih-An.

    1987-01-01

    The recent development of neutron activation analysis and mass spectrometric methods for the determination of 232 Th in seawater has made possible rapid sampling and analysis of this long-lived, non-radiogenic thorium isotope on small-volume samples. The marine geochemical utility of 232 Th, whose concentration in seawater is extremely low, warrants the development of these sensitive techniques. The analytical methods and some results are presented and discussed in this article. 24 refs., 3 figs

  6. Regional differences in brain glucose metabolism determined by imaging mass spectrometry

    OpenAIRE

    André Kleinridders; Heather A. Ferris; Michelle L. Reyzer; Michaela Rath; Marion Soto; M. Lisa Manier; Jeffrey Spraggins; Zhihong Yang; Robert C. Stanton; Richard M. Caprioli; C. Ronald Kahn

    2018-01-01

    Objective: Glucose is the major energy substrate of the brain and crucial for normal brain function. In diabetes, the brain is subject to episodes of hypo- and hyperglycemia resulting in acute outcomes ranging from confusion to seizures, while chronic metabolic dysregulation puts patients at increased risk for depression and Alzheimer's disease. In the present study, we aimed to determine how glucose is metabolized in different regions of the brain using imaging mass spectrometry (IMS). Metho...

  7. Radioimmunoassay and chemical ionization/mass spectrometry compared for plasma cortisol determination

    International Nuclear Information System (INIS)

    Lindberg, C.; Johnson, S.; Hedner, P.; Gustafsson, A.

    1982-01-01

    A method is described for determination of cortisol in plasma and urine, based on chemical ionization/mass spectrometry with deuterium-labeled cortisol as the internal standard. The within-run precision (CV) was 2.5-5.7%, the between-run precision 4.6%. Results by this method were compared with those by a radioimmunological method (RIANEN Cortisol, New England Nuclear) for 395 plasma samples. The latter method gave significantly higher (approx. 25%) cortisol values

  8. Movements and dive patterns of short-finned pilot whales (Globicephala macrorhynchus) released from a mass stranding in the Florida Keys

    Science.gov (United States)

    Wells, Randall S.; Fougeres, Erin M.; Cooper, Arthur G.; Stevens, Robert O.; Brodsky, Micah; Lingenfelser, Robert; Dold, Chris; Douglas, David C.

    2013-01-01

    Short-finned pilot whales (Globicephala macrorhynchus) are among the most common cetaceans to engage in mass strandings in the southeastern United States. Because these are primarily pelagic, continental shelf-edge animals, much of what is known about this species has derived from mass stranding events. Post-release monitoring via satellite-linked telemetry was conducted with two adult males determined on-site to be healthy, and released directly from a mass stranding of 23 pilot whales in May 2011, near Cudjoe Key, Florida. Tracking provided an opportunity to evaluate the decision for immediate release vs rehabilitation, and to learn more about the lives of members of this difficult-to-study species in the wild. The two pilot whales remained together for at least 16 d before transmissions from one pilot whale (Y-404) ceased. Dive patterns and travel rates suggested that Y-404’s condition deteriorated prior to signal loss. Pilot Whale Y-400 was tracked for another 51 d, moving from the Blake Plateau to the Greater Antilles, remaining in the Windward Passage east of Cuba for the last 17 d of tracking. Once he reached the Antilles, Y-400 remained in high-relief habitat appropriate for the species and made dives within or exceeding the reported range for depth and duration for this species, following expected diel patterns, presumably reflecting continued good health. Telemetry data indicate that he made at least one dive to 1,000 to 1,500 m, and several dives lasted more than 40 min. Although the fates of the two released pilot whales may have been different, the concept of evaluating health and releasing individuals determined to be healthy at the time of stranding appears to have merit as an alternative to bringing all members of mass-stranded pilot whale groups into rehabilitation.

  9. Determination of trace quantities of uranium in rocks mass spectrometric isotope dilution technique

    International Nuclear Information System (INIS)

    Kakazu, Mauricio Hiromitu

    1980-01-01

    A detailed experimental investigation on the thermionic emission of uranium deposited on a single flat type rhenium filament has been carried out. The study was aimed at determining the influence of various forms of deposition on the emission sensitivity and thermal stability of U + , UO + and UO 2 + ions. Based on these investigations, a technique, involving an addition of a small quantity of colloidal suspension of graphite on top of the uranyl nitrate sample deposited, was chosen because of its higher, emission sensitivity for uranium metal ions. The experimental parameters of the technique were optimised and the technique was employed in the determination of trace quantities of uranium in rock samples using mass spectrometric isotope dilution method. For the mass spectrometric isotope dilution analysis National Bureau of Standards uranium isotopic standard NBS-U 970 was employed as a tracer, where as the mass discrimination effect in the uranium isotope analysis was corrected using the uranium isotopic standard NBS-U500. Uranium was determined in each of the seven granite samples from Wyoming, USA and two USGS standard rocks. The precision of the analysis was found to be ±1% . The uranium values obtained on the rock samples were compared with the analyses of other investigators. Influence of the sample splitting on the uranium analysis was discussed in the light of the analytical results obtained.(author)

  10. [Determination of strobilurin fungicides in fruits and their mass fragmentation routes by ultra performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhou, Yao; Yang, Huiqin; Shi, Yiyin; Chen, Jiaxian; Zhu, Jian; Deng, Xiaojun; Guo, Dehua

    2017-09-08

    A method was developed for the simultaneous determination of six strobilurin fungicide ( E -metominostrobin, azoxystrobin, kresoxim-methyl, picoxystrobin, pyraclostrobin and trifloxystrobin) residues in orange, banana, apple and pineapple samples by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The fragmentation routes of all the compounds were explained by the aid of a fragment predicting software ACD Lab/MS Fragmenter. The samples were extracted by acetonitrile, then cleaned up by amino solid phase extraction cartridges (SupelClean LC-NH 2 ). The extracts were separated on a ACQUITY UPLC BEH C 18 column (50 mm×2.1 mm, 1.7 μm) with gradient elution. Acetonitrile containing 0.1% (v/v) formic acid and 10 mmol/L ammonium acetate containing 0.1% (v/v) formic acid were used as mobile phases. The samples were detected by electrospray ionization (ESI)-MS/MS in positive ion and multiple reaction monitoring (MRM) mode, quantified by external standard method. Good linearities were obtained in the range of 5-100 μg/L (for pyraclostrobin, 1-20 μg/L) with correlation coefficients ( r 2 ) greater than 0.999. The recoveries ranged from 60.4% to 120% with the relative standard deviations between 2.15% and 15.1% ( n =6). The developed method can meet the inspection of the six strobilurin residues in the orange, banana, apple and pineapple samples.

  11. Determination of sulfonamides in meat by liquid chromatography coupled with atmospheric pressure chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Kim, Dal Ho; Choi, Jong Oh; Kim, Jin Seog; Lee, Dai Woon

    2002-01-01

    Liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) has been used for the determination of sulfonamides in meat. Five typical sulfonamides were selected as target compounds, and beef meat was selected as a matrix sample. As internal standards, sulfapyridine and isotope labeled sulfamethazine ( 13 C 6 -SMZ) were used. Compared to the results of recent reports, our results have shown improved precision to a RSD of 1.8% for the determination of sulfamethazine spiked with 75 ng/g level in meat

  12. Determining the hierarchy of neutrino masses with high density magnetized detectors at the Beta Beams

    International Nuclear Information System (INIS)

    Donini, A.; Fernandez-Martinez, E.; Rigolin, S.; Migliozzi, P.; Lavina, L. Scotto; Selvi, M.; De Fatis, T. Tabarelli; Terranova, F.

    2008-01-01

    Multi-kton iron detectors can be simultaneously exploited as far detectors for high energy Beta Beams and to determine the atmospheric ν μ flux in the multi-GeV range. These measurements can be combined in a highly non trivial manner to improve the sensitivity to the hierarchy of neutrino masses. Considering a Super-SPS based Beta Beam and a 40 kton far detector located ∼700 km from the source (CERN to Gran Sasso distance), we demonstrate that even with moderate detector granularities the sign of Δm 13 2 can be determined for θ 13 values greater than 4 deg.

  13. Studies in the determination of lead isotope ratios by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Date, A.R.; Yuk Ying Cheung

    1987-01-01

    The application of ICP-MS to the determination of lead isotope ratios in geological materials is described. Data presented for a series of lead mineral concentrates are compared with reference values obtained by conventional solid source thermal ionisation mass spectrometry. The simultaneous determination of lead isotope ratios and trace elements is carried out in a rapid analysis mode. The application of an electrothermal vaporisation technique for small solution aliquots is described. Lead isotope ratio data for the United States Geological Survey standard reference silicate rock BCR-1, obtained without separation of lead from the matrix, are compared with previously published values obtained after separation. (author)

  14. [Rapid determination of 8 urinary carbamate pesticides by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Liu, Hualiang; Wang, Yuan; Zhu, Baoli

    2015-11-01

    To establish a method for simultaneously determining the urinary concentrations of 8 carbamate pesticides. After being purified by acetonitrile precipitation, urine samples were transferred to a liquid chromatography-tandem mass spectrometry system, and the concentrations of 8 carbamate pesticides were determined by external standard method. A C18 column was used for ultra-high-performance liquid chromatography; methanol/ammonium acetate solution was used as the mobile phase for gradient elution; the mass spectrometer was operated in a multi-reaction monitoring mode. The calibration curves were linear when the urinary concentrations of these carbamate pesticides were 20~800 µg/L, and the recovery rates were 61.0%~121% at spiked levels of 20, 200 and 800 µg/L, with a relative standard deviation of 1.7%~5.5%. This determination method meets the Guide for establishing occupational health standards-part 5: Determination methods of chemicals in biological materials, and can be used for simultaneous determination of 8 carbamate pesticides in the urine of poisoning patients.

  15. Determination of the W boson mass in the hadronic decay channel in the DELPHI experiment

    International Nuclear Information System (INIS)

    Zoller, Ph.

    2001-04-01

    The subject of this thesis is the determination of the boson W mass in the fully hadronic channel within DELPHI experiment. Data are collected by the detector DELPHI during 1998 and 1999 with the e + e - collider LEP at CERN. W bosons collected were produced by pair in the process e + e - → W + W - with a center of mass energy between 189 and 202 GeV. A significant part of work in the thesis was devoted to the pairing algorithm creation for the four jets and to the final mass determination of the W boson. An event per event log-likelihood method was used for the constrained fit. We also compare for each event selected the reconstructed mass for W + and W - bosons with simulated histograms corrected by a ratio of a modified Breit-Wigner function. Finally, the last part of my work has consisted in studying the influence, on one hand, of some parameters resulting from theoretical models and, on other hand, of the experimental observables responsible of a mass shift. So, I was able to study the systematics effects owing to the final state interactions, to parameters used by models of fragmentation and to their energy and angular resolution. The final result we get is M W = (80.430 ± 0.081 (stat) ± 0.037 (syst) ± 0.050 (FSI) ± 0.017 (LEP)) GeV/c 2 where 'stat' means statistical error, 'LEP' means systematic error due to the LEP beam energy, 'FSI' means systematic error due to the interconnection in the final state, and 'syst' means other systematic errors

  16. A review on the determination of isotope ratios of boron with mass spectrometry.

    Science.gov (United States)

    Aggarwal, Suresh Kumar; You, Chen-Feng

    2017-07-01

    The present review discusses different mass spectrometric techniques-viz, thermal ionization mass spectrometry (TIMS), inductively coupled plasma mass spectrometry (ICPMS), and secondary ion mass spectrometry (SIMS)-used to determine 11 B/ 10 B isotope ratio, and concentration of boron required for various applications in earth sciences, marine geochemistry, nuclear technology, environmental, and agriculture sciences, etc. The details of the techniques-P-TIMS, which uses Cs 2 BO 2 + , N-TIMS, which uses BO 2 - , and MC-ICPMS, which uses B + ions for bulk analysis or B - and B + ions for in situ micro-analysis with SIMS-are highlighted. The capabilities, advantages, limitations, and problems in each mass spectrometric technique are summarized. The results of international interlaboratory comparison experiments conducted at different times are summarized. The certified isotopic reference materials available for boron are also listed. Recent developments in laser ablation (LA) ICPMS and QQQ-ICPMS for solids analysis and MS/MS analysis, respectively, are included. The different aspects of sample preparation and analytical chemistry of boron are summarized. Finally, the future requirements of boron isotope ratios for future applications are also given. Presently, MC-ICPMS provides the best precision and accuracy (0.2-0.4‰) on isotope ratio measurements, whereas N-TIMS holds the potential to analyze smallest amount of boron, but has the issue of bias (+2‰ to 4‰) which needs further investigations. © 2016 Wiley Periodicals, Inc. Mass Spec Rev 36:499-519, 2017. © 2016 Wiley Periodicals, Inc.

  17. Atomic mass determinations for 183W and 199Hg and the mercury problem

    International Nuclear Information System (INIS)

    Barillari, D.K.; Vaz, J.V.; Barber, R.C.; Sharma, K.S.

    2003-01-01

    Recent modifications to the 'Manitoba II' high resolution mass spectrometer are described. Mass differences among the members of the triplet 199 Hg - 183 W 16 O- 12 C 2 35 Cl 5 have been measured. These self-consistent mass differences give masses for 183 W and 199 Hg, as well as the mass difference across the W to Hg region of the mass table. These masses and the mass difference provide important constraints for the least squares atomic mass evaluation

  18. Optimization method to determine mass transfer variables in a PWR crud deposition risk assessment tool

    International Nuclear Information System (INIS)

    Do, Chuong; Hussey, Dennis; Wells, Daniel M.; Epperson, Kenny

    2016-01-01

    Optimization numerical method was implemented to determine several mass transfer coefficients in a crud-induced power shift risk assessment code. The approach was to utilize a multilevel strategy that targets different model parameters that first changes the major order variables, mass transfer inputs, then calibrates the minor order variables, crud source terms, according to available plant data. In this manner, the mass transfer inputs are effectively simplified as 'dependent' on the crud source terms. Two optimization studies were performed using DAKOTA, a design and analysis toolkit, with the difference between the runs, being the number of model runs using BOA, allowed for adjusting the crud source terms, therefore, reducing the uncertainty with calibration. The result of the first case showed that the current best estimated values for the mass transfer coefficients, which were derived from first principle analysis, can be considered an optimized set. When the run limit of BOA was increased for the second case, an improvement in the prediction was obtained with the results deviating slightly from the best estimated values. (author)

  19. Recent advances in applying mass spectrometry and systems biology to determine brain dynamics.

    Science.gov (United States)

    Scifo, Enzo; Calza, Giulio; Fuhrmann, Martin; Soliymani, Rabah; Baumann, Marc; Lalowski, Maciej

    2017-06-01

    Neurological disorders encompass various pathologies which disrupt normal brain physiology and function. Poor understanding of their underlying molecular mechanisms and their societal burden argues for the necessity of novel prevention strategies, early diagnostic techniques and alternative treatment options to reduce the scale of their expected increase. Areas covered: This review scrutinizes mass spectrometry based approaches used to investigate brain dynamics in various conditions, including neurodegenerative and neuropsychiatric disorders. Different proteomics workflows for isolation/enrichment of specific cell populations or brain regions, sample processing; mass spectrometry technologies, for differential proteome quantitation, analysis of post-translational modifications and imaging approaches in the brain are critically deliberated. Future directions, including analysis of cellular sub-compartments, targeted MS platforms (selected/parallel reaction monitoring) and use of mass cytometry are also discussed. Expert commentary: Here, we summarize and evaluate current mass spectrometry based approaches for determining brain dynamics in health and diseases states, with a focus on neurological disorders. Furthermore, we provide insight on current trends and new MS technologies with potential to improve this analysis.

  20. Determination of plutonium-241 half-life by mass spectrometric measurement

    International Nuclear Information System (INIS)

    Hiyama, Takashi; Wada, Yukio; Onishi, Koichi

    1982-01-01

    Much data for Pu-241 half-life have been reported, but these values range from 13.8 years to 15.1 years depending on investigators. In order to define the half-life of Pu-241, the half-life was calculated by analyzing the mass spectrometry data obtained in the author's laboratory over the past six years on Plutonium Isotopic Standard Reference Materials prepared at the National Bureau of Standards (NBS). The sample used for this work consisted of SRM-947 and SRM-948 prepared at NBS. Before mass spectrometric analysis, the plutonium aliquot was separated from its Am-241 daughter by anion exchange chromatography, since Am-241 is not distinguished from Pu-241 in the mass spectrometer. 241 Pu/ 239 Pu and 241 Pu/ 240 Pu ratios were calculated from the values of mass spectrometric measurement. From the relation of log N to time, the half-life of Pu-241 was determined, based on the slope using a least squares fit. The half-life of Pu-241 was estimated to be 14.29+-0.15 years. (Yoshitake, I.)

  1. Higher body mass index is associated with greater severity of alopecia in men with male-pattern androgenetic alopecia in Taiwan: a cross-sectional study.

    Science.gov (United States)

    Yang, Chao-Chun; Hsieh, Fu-Nien; Lin, Li-Yu; Hsu, Chao-Kai; Sheu, Hamm-Ming; Chen, WenChieh

    2014-02-01

    Obesity is a risk factor for multiple health problems, but its association with androgenetic alopecia (AGA) remains controversial. We sought to determine the association between body mass index (BMI) and alopecia severity in men with AGA and early-onset AGA. A cross-sectional study was conducted. The medical charts and photographs of men with a clinical diagnosis of AGA were reviewed. In all, 189 men were enrolled with a mean age of 30.8 years. In male-pattern AGA (n = 142), men with severe alopecia (grade V-VII) had higher BMI than those with mild to moderate alopecia (grade I-IV) (25.1 vs 22.8 kg/m(2), P = .01). After multivariate adjustments, the risk for severe alopecia was higher in the overweight or obese (BMI ≥24 kg/m(2)) subjects with male-pattern AGA (odds ratio 3.52, P < .01). In early-onset male-pattern AGA (n = 46), the risk for having severe alopecia was also higher in the overweight or obese subjects (odds ratio 4.97, P = .03). Parameters used to evaluate obesity were limited because of the retrospective nature of the study. Higher BMI was significantly associated with greater severity of hair loss in men with male-pattern AGA, especially in those with early-onset AGA. Copyright © 2013 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  2. Progress in determination of long-lived radionuclides by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Becker, J.S.; Dietze, H.J.

    2000-01-01

    Mass spectrometric methods (such as inductively coupled plasma mass spectrometry - ICP-MS and laser ablation (LA)-ICP-MS) with their ability to provide a very sensitive multielemental and precise isotopic analysis have become established for the determination of radionuclides in quite different sample materials. The determination of long-lived radionuclides is of increasing interest for the characterization of radioactive waste materials and for the detection of radionuclide contamination in environmental materials in which several radioactive nuclides are present from fallout due to nuclear weapons testing, nuclear power plants or nuclear accidents. Due to its multielement capability, excellent sensitivity, low detection limits (up to sub pg I 1 range), very good precision, easy sample preparation and measurement procedures ICP-MS of aqueous solutions has been increasingly applied for the ultrasensitive determination of long-lived radionuclides such as 99 Tc, 129 I, 230 Th, 232 Th, 234 U, 235 U, 236 U, 239 Pu, 240 Pu and 241 Am and precise isotope ratio measurements of U,Th and Pu. The application especially of microanalytical methods (analysis of some MU by flow injection and on-line coupling techniques as capillary electrophoresis (CE-ICP-MS) or HPLC-ICP-MS) for the precise determination nuclide abundances and concentration of long-lived radionuclides at ultra trace concentration levels in radioactive waste and also for controlling contamination from radioactive waste in the environment is a challenging task

  3. Determination of the Median Lethal Dose and Electrophoretic Pattern of Hottentotta saulcyi (Scorpiones, Buthidae Scorpion Venom

    Directory of Open Access Journals (Sweden)

    ErsenAydın Yağmur

    2015-10-01

    Full Text Available Background: In this study, we investigated the lethal potency, electrophoretic protein pattern and in vivo effects of Hottentotta saulcyi scorpion venom in mice.Methods: Scorpions were collected at night, by using a UV lamp from Mardin Province, Turkey. Venom was obtained from mature H. saulcyi scorpions by electrical stimulation of the telson. The lethality of the venom was determined by i.v. injections using Swiss mice. In vivo effects of the venom were assessed by using the intraperitoneal route (ip injections into mice (20±1g and monitored for 24 h. The protein profiles of the scorpion venom were analyzed by NuPAGE® Novex® 4–12 % gradient Bis-Tris gel followed by Coomassie blue staining.Results: The lethal assay of the venom was 0.73 mg/kg in mice. We determined the electrophoretic protein pattern of this scorpion venom to be 4, 6, 9, 31, 35, 40, 46 and 69 kDa by SDS-PAGE. Analysis of electrophoresis indicated that H. saulcyi scorpion intoxicated mice exhibited autonomic nervous system symptoms (tachypnea, restlessness, hyperexcitability, convulsions, salivation, lacrimation, weakness.Conclusions: Hottentotta saulcyi scorpion venom includes short-chain neurotoxins and long-chain neurotoxins according to the electrophoretic protein patterns. The stings of H. saulcyi scorpion must be considered of risk for humans in the southeastern region, Turkey.

  4. Determination of peak bone mass density and composition in low income urban residents of metro Manila using isotope techniques

    International Nuclear Information System (INIS)

    Lim-Abrahan, M.A.

    2000-01-01

    The work described in this paper is a continuation of the first phase of the study, which is the determination of the peak bone mass density among residents of Metro Manila using dual energy x-ray absorptiometry. However, it also aims to correlate sex, body mass index, nutritional factors, physical activity and lifestyle to peak bone mass and thus attempts to explain any discrepancies in peak bone mass density to that seen in other countries

  5. Determining total hemoglobin mass by means of {sup 13}CO breath analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sowa, Marcus; Hering, Peter [Institut fuer Lasermedizin, Universitaetsklinikum Duesseldorf (Germany)

    2010-07-01

    The aim of our investigations is the development of a non-invasive method for the determination of the total hemoglobin mass in the human body by means of Cavity Leak-Out Spectroscopy (CALOS). The mentioned CALOS system utilizes a CO gas laser in the mid infrared region around 5{mu}m. This system allows isotopologue selective online measurements of {sup 13}CO with a sensitivity of 7 ppb.Hz{sup -1/2}. {sup 13}CO is a non radioactive isotopologue occurring in a ratio of about 1.1 % of the natural CO composition. CO is commonly known as a highly toxic gas but it is also endogenously produced during heme degradation. About 80 % of this CO is exhaled yielding to CO concentrations between 1 ppm to 4 ppm in healthy humans. Transportation of CO through the body is established by hemoglobin which has a high affinity towards CO. Because of this fact inhaled CO is taken up by the blood until equilibrium between the alveolar air and the blood is reached. By determining the exhaled CO concentrations before and after the inhalation of a certain amount of CO a measure for the t-Hb mass can be calculated. The enormous advantage of the isotopologue measurement is the very small amount of {sup 13}CO which can be used for harmless CO inhalation. All data necessary for calculating the t-Hb mass are obtained from breath measurements making this method non invasive.

  6. Mass Determination of Pluto and Charon from New Horizon REX Radio Science Observations

    Science.gov (United States)

    Paetzold, Martin; Andert, T. P.; Tyler, G.; Bird, M. K.; Hinson, D. P.; Linscott, I. R.

    2013-10-01

    The anticipated 14 July 2015 New Horizons fly-through of the Pluto system provides the first opportunity to determine both the total system mass and the individual masses of Pluto and Charon by direct observation. This will be accomplished by use of: i) two-way Doppler radio frequency tracking data during intervals along the fly-in and -out trajectory, and ii) one-way uplink Doppler frequency recorded by the on-board radio science instrument, REX, during the day of closest approaches to Pluto and Charon. Continuous tracking is not feasible as a result of pointing sharing with the instruments during the encounter phase. Needed radio tracking will be obtained during time slots shared with i) two-way Doppler tracking for navigation, ii) 'plasma rolls' with the spacecraft antenna pointing to Earth, and iii) during the ingress and egress phases of the occultations. Simulations of the NH encounter indicate the potential accuracies of the combined and individual mass determinations of Pluto and Charon in the order of 0.1%.

  7. [Determination of Heavy Metal Elements in Diatomite Filter Aid by Inductively Coupled Plasma Mass Spectrometry].

    Science.gov (United States)

    Nie, Xi-du; Fu, Liang

    2015-11-01

    This study established a method for determining Be, Cr, Ni, As, Cd, Sb, Sn, Tl, Hg and Pb, total 10 heavy metals in diatomite filter aid. The diatomite filter aid was digested by using the mixture acid of HNO₃ + HF+ H₃PO₄ in microwave system, 10 heavy metals elements were determined by inductively coupled plasma mass spectrometry (ICP-MS). The interferences of mass spectrometry caused by the high silicon substrate were optimized, first the equipment parameters and isotopes of test metals were selected to eliminate these interferences, the methane was selected as reactant gas, and the mass spectral interferences were eliminated by dynamic reaction cell (DRC). Li, Sc, Y, In and Bi were selected as the internal standard elements to correct the interferences caused by matrix and the drift of sensitivity. The results show that the detection limits for analyte is in the range of 3.29-15.68 ng · L⁻¹, relative standard deviations (RSD) is less than 4.62%, and the recovery is in the range of 90.71%-107.22%. The current method has some advantages such as, high sensitivity, accurate, and precision, which can be used in diatomite filter aid quality control and safety estimations.

  8. Biogeographic and bathymetric determinants of brachiopod extinction and survival during the Late Ordovician mass extinction

    DEFF Research Database (Denmark)

    Finnegan, Seth; Mac Ørum Rasmussen, Christian; Harper, David A. T.

    2016-01-01

    –Early Silurian genus extinctions and evaluate which extinction drivers are best supported by the data. The first (latest Katian) pulse of the LOME preferentially affected genera restricted to deeper waters or to relatively narrow (less than 35°) palaeolatitudinal ranges. This pattern is only observed...... in the latest Katian, suggesting that it reflects drivers unique to this interval. Extinction of exclusively deeper-water genera implies that changes in water mass properties such as dissolved oxygen content played an important role. Extinction of genera with narrow latitudinal ranges suggests that interactions...... between shifting climate zones and palaeobiogeography may also have been important. We test the latter hypothesis by estimating whether each genus would have been able to track habitats within its thermal tolerance range during the greenhouse–icehouse climate transition. Models including these estimates...

  9. Higher order and heavy quark mass effects in the determination of parton distribution functions

    Energy Technology Data Exchange (ETDEWEB)

    Bertone, Valerio

    2013-07-01

    The present thesis was devoted to the study of the inclusion of higher-order corrections and heavy quark mass effects in a PDF determination. This has been carried out in the NNPDF framework resulting originally in the NNPDF2.1 sets, which were at a later stage supplemented by the first LHC data leading to the most recent NNPDF2.3 sets. In Chapter 1 the concept of Parton Distribution Function (PDF) was introduced. We have shown how the analytical computation of the Deep-Inelastic-Scattering (DIS) process at order α{sub s} in QCD leads to initial-stale collinear divergences which, using the factorization theorem, can be reabsorbed into the PDFs. The energy dependence of PDFs is fully determined and the task is then reduced to the determination of the x (Bjorken variable) dependence. In Chapter 2 a detailed discussion of the factorization schemes presently available to include heavy quark mass effects into DIS structure functions has been given. It emerged that there are two possible basic approaches to the calculation of the DIS structure functions. In the first approach, the so-called Fixed-Flavour-Number Scheme (FFNS), the calculation is performed retaining the quark mass of the heavy flavours which provide a ''natural'' regulator for the infrared divergences. In the second approach, called Zero-Mass Variable-Flavour-Number Scheme (ZM-VFNS), the heavy quark masses are instead set to zero and this gives rise to the usual final-state collinear divergences that are absorbed into the PDFs. In addition, in the ZM-VFNS, the number of active flavours is assumed to increase by one unity as the energy of the process crosses the energy threshold of a given heavy quark. In order to obtain a factorization scheme that is accurate both at large and low energies, several prescriptions that interpolate between FFNS at low energy and ZM-VFNS at large energy have been proposed and implemented in as many PDF fits. In Chapter 2 they have been described showing how they behave for

  10. Higher order and heavy quark mass effects in the determination of parton distribution functions

    Energy Technology Data Exchange (ETDEWEB)

    Bertone, Valerio

    2013-07-01

    The present thesis was devoted to the study of the inclusion of higher-order corrections and heavy quark mass effects in a PDF determination. This has been carried out in the NNPDF framework resulting originally in the NNPDF2.1 sets, which were at a later stage supplemented by the first LHC data leading to the most recent NNPDF2.3 sets. In Chapter 1 the concept of Parton Distribution Function (PDF) was introduced. We have shown how the analytical computation of the Deep-Inelastic-Scattering (DIS) process at order α{sub s} in QCD leads to initial-stale collinear divergences which, using the factorization theorem, can be reabsorbed into the PDFs. The energy dependence of PDFs is fully determined and the task is then reduced to the determination of the x (Bjorken variable) dependence. In Chapter 2 a detailed discussion of the factorization schemes presently available to include heavy quark mass effects into DIS structure functions has been given. It emerged that there are two possible basic approaches to the calculation of the DIS structure functions. In the first approach, the so-called Fixed-Flavour-Number Scheme (FFNS), the calculation is performed retaining the quark mass of the heavy flavours which provide a ''natural'' regulator for the infrared divergences. In the second approach, called Zero-Mass Variable-Flavour-Number Scheme (ZM-VFNS), the heavy quark masses are instead set to zero and this gives rise to the usual final-state collinear divergences that are absorbed into the PDFs. In addition, in the ZM-VFNS, the number of active flavours is assumed to increase by one unity as the energy of the process crosses the energy threshold of a given heavy quark. In order to obtain a factorization scheme that is accurate both at large and low energies, several prescriptions that interpolate between FFNS at low energy and ZM-VFNS at large energy have been proposed and implemented in as many PDF fits. In Chapter 2 they have been described showing

  11. Higher order and heavy quark mass effects in the determination of parton distribution functions

    International Nuclear Information System (INIS)

    Bertone, Valerio

    2013-01-01

    The present thesis was devoted to the study of the inclusion of higher-order corrections and heavy quark mass effects in a PDF determination. This has been carried out in the NNPDF framework resulting originally in the NNPDF2.1 sets, which were at a later stage supplemented by the first LHC data leading to the most recent NNPDF2.3 sets. In Chapter 1 the concept of Parton Distribution Function (PDF) was introduced. We have shown how the analytical computation of the Deep-Inelastic-Scattering (DIS) process at order α s in QCD leads to initial-stale collinear divergences which, using the factorization theorem, can be reabsorbed into the PDFs. The energy dependence of PDFs is fully determined and the task is then reduced to the determination of the x (Bjorken variable) dependence. In Chapter 2 a detailed discussion of the factorization schemes presently available to include heavy quark mass effects into DIS structure functions has been given. It emerged that there are two possible basic approaches to the calculation of the DIS structure functions. In the first approach, the so-called Fixed-Flavour-Number Scheme (FFNS), the calculation is performed retaining the quark mass of the heavy flavours which provide a ''natural'' regulator for the infrared divergences. In the second approach, called Zero-Mass Variable-Flavour-Number Scheme (ZM-VFNS), the heavy quark masses are instead set to zero and this gives rise to the usual final-state collinear divergences that are absorbed into the PDFs. In addition, in the ZM-VFNS, the number of active flavours is assumed to increase by one unity as the energy of the process crosses the energy threshold of a given heavy quark. In order to obtain a factorization scheme that is accurate both at large and low energies, several prescriptions that interpolate between FFNS at low energy and ZM-VFNS at large energy have been proposed and implemented in as many PDF fits. In Chapter 2 they have been described showing how

  12. [Study on the determination of 14 inorganic elements in coffee by inductively coupled plasma mass spectrometry].

    Science.gov (United States)

    Nie, Xi-Du; Fu, Liang

    2013-07-01

    Samples of coffee were digested by microwave digestion, and inorganic elements amounts of Na, Mg, P, Ca, Cr, Mn, Fe, Co, Cu, Zn, As, Se, Mo and Pb in sample solutions were determined by inductively coupled plasma mass spectrometry (ICP-MS). HNO3 + H2O2 was used to achieve the complete decomposition of the organic matrix in a closed-vessel microwave oven. The working parameters of the instrument were optimized. The results showed that the relative standard deviation (RSD) was less than 3.84% for all the elements, and the recovery was found to be 92.00% -106.52% by adding standard recovery experiment. This method was simple, sensitive and precise and can perform simultaneous multi-elements determination of coffee, which could satisfy the sample examination request and provide scientific rationale for determining inorganic elements of coffee.

  13. Extractive alkylation of 6-mercaptopurine and determination in plasma by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Floberg, S; Hartvig, P; Lindström, B; Lönner-Holm, G; Odlind, B

    1981-09-11

    An analytical procedure was developed for the determination of 6-mercaptopurine in plasma. Owing to the polar character and low plasma concentration of the compound, extraction and derivatization was carried out directly from the plasma sample by extractive alkylation. Determination was made using gas chromatography-mass spectrometry with multiple-ion detection. Conditions with respect to the rate of formation and the stability of the derivative formed in the extractive alkylation step were evaluated. The selectively of the method to azathioprine and to metabolites was thoroughly investigated. No 6-mercaptopurine was formed from azathioprine added to water or plasma and run through the method. The method enables the detection of 2 ng of 6 mercaptopurine in a 1.0-ml plasma sample. Quantitative determinations were done down to 10 ng/ml 6 mercaptopurine in plasma.

  14. Determination of the η mass with the Crystal Ball at MAMI-B

    International Nuclear Information System (INIS)

    Nikolaev, A.; Beck, R.; Lang, M.; Aguar-Bartolome, P.; Ahrens, J.; Arends, H.J.; Dehn, M.; Heid, E.; Jahn, O.; Jankowiak, A.; Kaiser, K.H.; Krambrich, D.; Ludwig-Mertin, U.; Martinez-Fabregate, M.; Rost, M.; Thomas, A.; Walcher, T.; Annand, J.R.M.; Codling, R.; Downie, E.J.; Livingston, K.; MacGregor, I.J.D.; McGeorge, J.C.; Owens, R.O.; Rosner, G.; Bekrenev, V.; Boillat, B.; Krusche, B.; Zehr, F.; Braghieri, A.; Pedroni, P.; Branford, D.; Glazier, D.I.; Tarbert, C.M.; Watts, D.P.; Briscoe, W.J.; Brudvik, J.W.; Nefkens, B.M.K.; Prakhov, S.N.; Price, J.W.; Starostin, A.; Cherepnya, S.; Fil'kov, L.V.; Gregor, R.; Kotulla, M.; Lugert, S.; Metag, V.; Novotny, R.; Hornidge, D.; Kashevarov, V.L.; Kondratiev, R.; Lisin, V.; Polonski, A.; Korolija, M.; Mekterovic, D.; Supek, I.; Manley, D.M.; Reiter, A.; Rostomyan, T.; Schumann, S.; Unverzagt, M.; Sober, D.

    2014-01-01

    A new precise determination of the η meson mass is presented. It is based on a measurement of the threshold for the γp → pη reaction using the tagger focal-plane microscope detector at the MAMI-B facility in Mainz. The tagger microscope has a higher energy resolution than the standard tagging spectrometer and, hence, allowed an improvement in the accuracy compared to the previous η mass measurement at MAMI-B. Special emphasis was put on a very careful energy calibration of the electron beam and the tagging device, which reduced considerably the systematic uncertainty compared to the previous MAMI experiment. The result m η = (547.865 ± 0.031 stat. ± 0.062 syst. ) MeV agrees very well with the precise values of the NA48, KLOE, CLEO and COSY-ANKE Collaborations and deviates by 6σ from the smaller value obtained by the GEM Collaboration at COSY. (orig.)

  15. In situ determination of a rock mass modulus using a high resolution tiltmeter

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, B.; Husein Malkawi, A.I. [University of Jordan, Amman (Jordan); Blum, P.A. [Universite Pierre et Marie Curie, 75 - Paris (France)

    1996-04-01

    A very sensitive, compact tiltmeter made of melted silica, developed for the measurement of small deformations of various civil engineering structures, was described. The instrument is capable of giving a continuous record and was used to establish a new approach to directly evaluating the in situ average elastic rock mass modulus. Such information is important in decision making during the design stages of large civil engineering works, such as dams, nuclear plant facilities, and underground structures. Five tiltmeters were installed on the facades of the Louvre in Paris to study the deformation induced by internal structural work and by the impact of the Paris metro traffic movement. The data was used to determine displacement using the Boussinesq equation. Results were consistent with typical elastic rock-mass modulus for the rock found in the museum`s foundations. 13 refs., 1 tab., 10 figs.

  16. Determination of the top-quark mass from hadro-production of single top-quarks

    International Nuclear Information System (INIS)

    Alekhin, S.; Moch, S.; Thier, S.

    2016-08-01

    We present a new determination of the top-quark mass m_t based on the experimental data from the Tevatron and the LHC for single-top hadro-production. We use the inclusive cross sections of s- and t-channel top-quark production to extract m_t and to minimize the dependence on the strong coupling constant and the gluon distribution in the proton compared to the hadro-production of top-quark pairs. As part of our analysis we compute the next-to-next-to-leading order approximation for the s-channel cross section in perturbative QCD based on the known soft-gluon corrections and implement it in the program HatHor for the numerical evaluation of the hadronic cross section. Results for the top-quark mass are reported in the MS and in the on-shell renormalization scheme.

  17. A Large Cardiac Mass: Diagnosis of Caseous Mitral Annular Calcification and Determining Optimum Management Strategy

    Directory of Open Access Journals (Sweden)

    Emanuel A. Shapera

    2014-01-01

    Full Text Available A 64-year-old woman with dizziness and blurry vision underwent an evaluation for a possible stroke with a head-neck CT scan and a transthoracic echocardiogram. The head-neck CT scan was unremarkable, but the echocardiogram was notable for a 2.0×2.3 cm heterogeneous echodensity attached to the mitral valve. After a transesophageal echocardiogram and chest CT scan, the mass was determined to be a caseous mitral annular calcification, CMAC. This entity is a rare variant of MAC with an estimated prevalence of 0.068%. Echocardiographic techniques can distinguish CMAC from other intracardiac masses such as tumor, cyst, or abscess. CMAC is associated with cerebrovascular accidents; however, optimal treatment is controversial given the rarity of this clinical finding. Management strategies should be tailored based on the patient’s presentation, risk factors, and overall clinical circumstances.

  18. Bone mass determination from microradiographs by computer-assisted videodensitometry. Pt. 2

    International Nuclear Information System (INIS)

    Kaelebo, P.; Strid, K.G.

    1988-01-01

    Aluminium was evaluated as a reference substance in the assessment of rabbit cortical bone by microradiography followed by videodensitometry. Ten dense, cortical-bone specimens from the same tibia diaphysis were microradiographed using prefiltered 27 kV roentgen radiation together with aluminium step wedges and bone simulating phantoms for calibration. Optimally exposed and processed plates were analysed by previously described computer-assisted videodensitometry. For comparison, the specimens were analysed by physico-chemical methods. A strict proportionality was found between the 'aluminium equivalent mass' and the ash weight of the specimens. The total random error was low with a coefficient of variation within 1.5 per cent. It was concluded that aluminium is an appropriate reference material in the determination of cortical bone, which it resembles in effective atomic number and thus X-ray attenuation characteristics. The 'aluminium equivalent mass' is suitably established as the standard of expressing the results of bone assessment by microradiography. (orig.)

  19. Determination of clarithromycin in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Jiang, Yao; Wang, Jiang; Li, Hao; Wang, Yingwu; Gu, Jingkai

    2007-03-12

    A rapid and sensitive method has been developed for the determination of clarithromycin in human plasma with liquid chromatography-tandem mass spectrometry. Clarithromycin and the internal standard, telmisartan were precipitated from the matrix (50 microl) with 200 microl acetonitrile and separated by HPLC using formic acid:10 mM ammonium acetate:methanol (1:99:400, v/v/v) as the mobile phase. The assay based on detection by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring mode was finished within 2.4 min. Linearity was over the concentration range 10-5000 ng/ml with a limit of detection of 0.50 ng/ml. Intra- and inter-day precision measured as relative standard deviation were bioequivalence study of two tablet formulations of clarithromycin.

  20. The determination of precious metals in geological samples by ICP - Mass Spectrometry

    International Nuclear Information System (INIS)

    Denoyer, E.; Ediger, R.; Hager, J.

    1989-01-01

    ICP - mass spectrometry with laser sampling has been used to determine gold directly in solid fire assay beads. A small portion of the lead bead is vaporized by Nd: YAG laser, and the resulting particulate material is passed by a flow of argon an ICP-mass spectrometer for quantitation of the gold content. Calibration with known geological materials gives linear calibration curves, and detection limits for gols are estimated to be 0.07 micrograms/gram in the original ore sample. The repeatability of the method is similar to that expected for traditional fire assay methods, and the analysis time for the solid lead bead is less than five minutes per sample. (author) [pt

  1. Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saraner, Nihal; Özkan, Güler Yağmur; Güney, Berrak; Alkan, Erkin; Burul-Bozkurt, Nihan; Sağlam, Onursal; Fikirdeşici, Ezgi; Yıldırım, Mevlüt

    2016-06-01

    A rapid, simple and sensitive method was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determination of albendazole sulfoxide (ABZOX) in human plasma. The plasma samples were extracted by protein precipitation using albendazole sulfoxide-d3 as internal standard (IS). The chromatographic separation was performed on Waters Xbridge C18Column (100×4.6mm, 3.5μm) with a mobile phase consisting of ammonia solution, water and methanol at a flow rate of 0.70mL/min. ABZOX was detected and identified by mass spectrometry with electrospray ionization (ESI) in positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 3-1500ng/mL for ABZOX. This method was successfully applied to the bioequivalence study in human plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Use of Data Mining to Reveal Body Mass Index (BMI): Patterns among Pennsylvania Schoolchildren, Pre-K to Grade 12

    Science.gov (United States)

    YoussefAgha, Ahmed H.; Lohrmann, David K.; Jayawardene, Wasantha P.

    2013-01-01

    Background: Health eTools for Schools was developed to assist school nurses with routine entries, including height and weight, on student health records, thus providing a readily accessible data base. Data-mining techniques were applied to this database to determine if clinically signi?cant results could be generated. Methods: Body mass index…

  3. Spatial patterns of bacterial abundance, activity and community composition in relation to water masses in the eastern Mediterranean Sea

    NARCIS (Netherlands)

    Yokokawa, Taichi; De Corte, Daniele; Sintes, Eva; Herndl, Gerhard J.

    2010-01-01

    To determine the variation of bacterial activity and community composition between and within specific water masses, samples were collected throughout the water column at 5 stations in the eastern Mediterranean Sea corresponding to the regions of the northern Aegean, mid-Aegean, western Cretan,

  4. Radionuclide determination in environmental samples by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lariviere, Dominic; Taylor, Vivien F.; Evans, R. Douglas; Cornett, R. Jack

    2006-01-01

    The determination of naturally occurring and anthropogenic radionuclides in the environment by inductively coupled plasma mass spectrometry has gained recognition over the last fifteen years, relative to radiometric techniques, as the result of improvement in instrumental performance, sample introduction equipment, and sample preparation. With the increase in instrumental sensitivity, it is now possible to measure ultratrace levels (fg range) of many radioisotopes, including those with half-lives between 1 and 1000 years, without requiring very complex sample pre-concentration schemes. However, the identification and quantification of radioisotopes in environmental matrices is still hampered by a variety of analytical issues such as spectral (both atomic and molecular ions) and non-spectral (matrix effect) interferences and instrumental limitations (e.g., abundance sensitivity). The scope of this review is to highlight recent analytical progress and issues associated with the determination of radionuclides by inductively coupled plasma mass spectrometry. The impact of interferences, instrumental limitations (e.g., degree of ionization, abundance sensitivity, detection limits) and low sample-to-plasma transfer efficiency on the measurement of radionuclides by inductively coupled plasma mass spectrometry will be described. Solutions that overcome these issues will be discussed, highlighting their pros and cons and assessing their impact on the measurement of environmental radioactivity. Among the solutions proposed, mass and chemical resolution through the use of sector-field instruments and chemical reactions/collisions in a pressurized cell, respectively, will be described. Other methods, such as unique sample introduction equipment (e.g., laser ablation, electrothermal vaporisation, high efficiency nebulization) and instrumental modifications/optimizations (e.g., instrumental vacuum, radiofrequency power, guard electrode) that improve sensitivity and performance

  5. Novel insight into neutrophil immune responses by dry mass determination of Candida albicans morphotypes.

    Directory of Open Access Journals (Sweden)

    Ava Hosseinzadeh

    Full Text Available The common fungal pathogen Candida albicans has the ability to grow as a yeast or as a hypha and can alternate between these morphotypes. The overall biomass of both morphotypes increases with growth. However, only yeasts, but not hyphae, exist as discrete cellular entities. Multiplicity of infection (MOI is a useful parameter to determine the initial inoculum of yeasts for in vitro infection assays. Since the amount of hyphae is difficult to quantify, comparable starting conditions in such assays cannot be determined accurately for yeasts and hyphae using MOI. To circumvent this problem, we have established a set of correlation coefficients to convert fungal metabolic activity and optical density to dry mass. Using these correlations, we were able to accurately compare ROS production and IL-8 release by polymorphonuclear neutrophils upon infection with equal dry mass amounts of yeast and hyphal morphotypes. Neutrophil responses depended on the initial form of infection, irrespective of C. albicans wild-type yeasts transforming to hyphal growth during the assay. Infection with a high mass of live C. albicans yeasts resulted in lower neutrophil ROS and this decrease stems from efficient ROS detoxification by C. albicans without directly affecting the phagocyte ROS machinery. Moreover, we show that dead C. albicans induces significantly less ROS and IL-8 release than live fungi, but thimerosal-killed C. albicans were still able to detoxify neutrophil ROS. Thus, the dry mass approach presented in this study reveals neutrophil responses to different amounts and morphotypes of C. albicans and serves as a template for studies that aim to identify morphotype-specific responses in a variety of immune cells.

  6. Revisiting ρ1 Cancri e: A New Mass Determination of the Transiting Super-Earth

    Science.gov (United States)

    Endl, Michael; Robertson, Paul; Cochran, William D.; MacQueen, Phillip J.; Brugamyer, Erik J.; Caldwell, Caroline; Wittenmyer, Robert A.; Barnes, Stuart I.; Gullikson, Kevin

    2012-11-01

    We present a mass determination for the transiting super-Earth ρ1 Cancri e based on nearly 700 precise radial velocity (RV) measurements. This extensive RV data set consists of data collected by the McDonald Observatory planet search and published data from Lick and Keck observatories. We obtained 212 RV measurements with the Tull Coudé Spectrograph at the Harlan J. Smith 2.7 m Telescope and combined them with a new Doppler reduction of the 131 spectra that we have taken in 2003-2004 with the High-Resolution Spectrograph (HRS) at the Hobby-Eberly Telescope for the original discovery of ρ1 Cancri e. Using this large data set we obtain a five-planet Keplerian orbital solution for the system and measure an RV semi-amplitude of K = 6.29 ± 0.21 m s-1 for ρ1 Cnc e and determine a mass of 8.37 ± 0.38 M ⊕. The uncertainty in mass is thus less than 5%. This planet was previously found to transit its parent star, which allowed them to estimate its radius. Combined with the latest radius estimate from Gillon et al., we obtain a mean density of ρ = 4.50 ± 0.20 g cm-3. The location of ρ1 Cnc e in the mass-radius diagram suggests that the planet contains a significant amount of volatiles, possibly a water-rich envelope surrounding a rocky core. Based partly on observations obtained with the Hobby-Eberly Telescope, which is a joint project of the University of Texas at Austin, the Pennsylvania State University, Stanford University, Ludwig-Maximilians-Universität München, and Georg-August-Universität Göttingen.

  7. ADVANTAGES OF RAPID METHOD FOR DETERMINING SCALE MASS AND DECARBURIZED LAYER OF ROLLED COIL STEEL

    Directory of Open Access Journals (Sweden)

    E. V. Parusov

    2016-08-01

    Full Text Available Purpose. To determine the universal empirical relationships that allow for operational calculation of scale mass and decarbonized layer depth based on the parameters of the technological process for rolled coil steel production. Methodology. The research is carried out on the industrial batches of the rolled steel of SAE 1006 and SAE 1065 grades. Scale removability was determined in accordance with the procedure of «Bekaert» company by the specifi-cations: GA-03-16, GA-03-18, GS-03-02, GS-06-01. The depth of decarbonized layer was identified in accordance with GOST 1763-68 (M method. Findings. Analysis of experimental data allowed us to determine the rational temperature of coil formation of the investigated steel grades, which provide the best possible removal of scale from the metal surface, a minimal amount of scale, as well as compliance of the metal surface color with the require-ments of European consumers. Originality. The work allowed establishing correlation of the basic quality indicators of the rolled coil high carbon steel (scale mass, depth of decarbonized layer and inter-laminar distance in pearlite with one of the main parameters (coil formation temperature of the deformation and heat treatment mode. The re-sulting regression equations, without metallographic analysis, can be used to determine, with a minimum error, the quantitative values of the total scale mass, depth of decarbonized layer and the average inter-lamellar distance in pearlite of the rolled coil high carbon steel. Practical value. Based on the specifications of «Bekaert» company (GA-03-16, GA-03-18, GS-03-02 and GS-06-01 the method of testing descaling by mechanical means from the surface of the rolled coil steel of low- and high-carbon steel grades was developed and approved in the environment of PJSC «ArcelorMittal Kryvyi Rih». The work resulted in development of the rapid method for determination of total and remaining scale mass on the rolled coil steel

  8. Determinants of changes in dietary patterns among Chinese immigrants: a cross-sectional analysis

    Directory of Open Access Journals (Sweden)

    Seidell Jaap

    2011-05-01

    Full Text Available Abstract Background Chinese individuals who have immigrated to a Western country initially tend to have a lower risk of cardiovascular disease (CVD compared to people who are already living there. Some studies have found, however, that CVD risk increases over time in immigrants and that immigration to a western country is associated with changes in dietary patterns. This could have unfavourable effects on the risk of CVD. There is limited knowledge on the food patterns, awareness and knowledge about healthy nutrition among Chinese immigrants. The objective for this study is to explore changes in food patterns, and levels of awareness and knowledge of healthy nutrition by length of residence among Chinese immigrants to Canada. Methods 120 Chinese individuals born in China but currently living in Canada completed an assessment on socio-demographic characteristics, changes in dietary patterns and variables of awareness and knowledge about healthy foods. With ordinal logistic regression the associations between the quartiles of length of residence and dietary patterns, variables of awareness and knowledge about healthy foods were explored, adjusting for age, sex, education and body mass index. Results More than 50% of the participants reported increasing consumption of fruits and vegetables, decreasing the use of deep-frying after immigration. Increased awareness and knowledge about healthy foods was reported by more than 50% of the participants. Ordinal regression indicated that Chinese immigrants who lived in Canada the longest, compared to Chinese immigrants who lived in Canada the shortest, consumed significant greater portion sizes (OR: 9.9; 95% CI: 3.11 - 31.15, dined out more frequently (OR: 15.8; 95% CI: 5.0 - 49.85, and consumed convenience foods more often (OR: 3.5; 95% CI: 1.23 - 10.01. Conclusions Chinese immigrants reported some favourable changes in their dietary intake and greater awareness and more knowledge about healthy foods after

  9. Paleoclimate determines diversification patterns in the fossorial snake family Uropeltidae Cuvier, 1829.

    Science.gov (United States)

    Cyriac, Vivek Philip; Kodandaramaiah, Ullasa

    2017-11-01

    Understanding how and why diversification rates vary across evolutionary time is central to understanding how biodiversity is generated and maintained. Recent mathematical models that allow estimation of diversification rates across time from reconstructed phylogenies have enabled us to make inferences on how biodiversity copes with environmental change. Here, we explore patterns of temporal diversification in Uropeltidae, a diverse fossorial snake family. We generate a time-calibrated phylogenetic hypothesis for Uropeltidae and show a significant correlation between diversification rate and paleotemperature during the Cenozoic. We show that the temporal diversification pattern of this group is punctuated by one rate shift event with a decrease in diversification and turnover rate between ca. 11Ma to present, but there is no strong support for mass extinction events. The analysis indicates higher turnover during periods of drastic climatic fluctuations and reduced diversification rates associated with contraction and fragmentation of forest habitats during the late Miocene. Our study highlights the influence of environmental fluctuations on diversification rates in fossorial taxa such as uropeltids, and raises conservation concerns related to present rate of climate change. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Social and health behavioural determinants of maternal child-feeding patterns in preschool-aged children.

    Science.gov (United States)

    Moreira, Isabel; Severo, Milton; Oliveira, Andreia; Durão, Catarina; Moreira, Pedro; Barros, Henrique; Lopes, Carla

    2016-04-01

    Parental child-feeding attitudes and practices may compromise the development of healthy eating habits and adequate weight status in children. This study aimed to identify maternal child-feeding patterns in preschool-aged children and to evaluate their association with maternal social and health behavioural characteristics. Trained interviewers evaluated 4724 dyads of mothers and their 4-5-year-old child from the Generation XXI cohort. Maternal child-feeding attitudes and practices were assessed through the Child Feeding Questionnaire and the Overt/Covert Control scale. Associations were estimated using linear regression [adjusted for maternal education, body mass index (BMI), fruit and vegetables (F&V) intake and child's BMI z-score]. Principal component analysis defined a three-factor structure explaining 58% of the total variance of maternal child-feeding patterns: perceived monitoring - representing mothers with higher levels of monitoring, perceived responsibility and overt control; restriction - characterizing mothers with higher covert control, restriction and concerns about child's weight; pressure to eat - identifying mothers with higher levels of pressure to eat and overt control. Lower socioeconomic status, better health perception, higher F&V intake and offspring cohabitation were associated with more 'perceived monitoring' mothers. Higher maternal F&V intake and depression were associated with more 'restrictive' mothers. Younger mothers, less educated, with poorer health perception and offspring cohabiting, were associated with higher use of 'pressure to eat'. Maternal socioeconomic indicators and family environment were more associated with perceived monitoring and pressure to eat, whereas maternal health behavioural characteristics were mainly associated with restriction. These findings will be helpful in future research and public health programmes on child-feeding patterns. © 2014 John Wiley & Sons Ltd.

  11. Determination of iodine in oyster tissue by isotope dilution laser resonance ionization mass spectrometry

    International Nuclear Information System (INIS)

    Fassett, J.D.; Murphy, T.J.

    1990-01-01

    The technique of laser resonance ionization mass spectrometry has been combined with isotope dilution analysis to determine iodine in oyster tissue. The long-lived radioisotope, 129I, was used to spike the samples. Samples were equilibrated with the 129I, wet ashed under controlled conditions, and iodine separated by coprecipitation with silver chloride. The analyte was dried as silver ammonium iodide upon a tantalum filament from which iodine was thermally desorbed in the resonance ionization mass spectrometry instrument. A single-color, two-photon resonant plus one-photon ionization scheme was used to form positive iodine ions. Long-lived iodine signals were achieved from 100 ng of iodine. The precision of 127I/129I measurement has been evaluated by replicate determinations of the spike, the spike calibration samples, and the oyster tissue samples and was 1.0%. Measurement precision among samples was 1.9% for the spike calibration and 1.4% for the oyster tissue. The concentration of iodine determined in SRM 1566a, Oyster Tissue, was 4.44 micrograms/g with an estimate of the overall uncertainty for the analysis of +/- 0.12 microgram/g

  12. Determination of impurity elements in steel by spark source mass spectrometry using powdered salts

    International Nuclear Information System (INIS)

    Saito, Morimasa; Sudo, Emiko

    1975-01-01

    Determination of impurity elements in steel by speak source mass spectrometry using powdered salts sample electrode was studied. The instrument used in this study was an AEI MS-7 mass spectrograph and the ion detector was Ilford Q2 photograph. Sample, (0.5--1) gram, was dissolved in hydrochloric acid (1 : 1) or nitric acid (1 : 1) together with yttrium of 1 microgram as the internal standard and then the solution was evaporated to dryness without baking. The salt residues were dried at 70 0 C for 30 minutes under vacuum. They were mixed with an equal amount of graphite powder for 5 minutes in a mixer mill, and then pressed into electrodes. When the relative sensitivity coefficient (Fe=1) was determined by using NBS 460 series standard samples, the results obtained by the proposed method for elements of Mo, Sn, Cu, Cr, Co, Ni, Mn, V, P, Si, and B were in good agreement with those obtained by the conventional method using solid sample electrodes (the solid method) and the precision of this method for 11 elements mentioned above was about 10% better than those of the solid method. However, both the accuracy and precision for elements of Nb, Ti, S and W were not good. This method was applied to the determination of impurities in NBS stainless steel and others. The relative standard deviations were within 20%. (auth.)

  13. Plutonium determination in seawater by inductively coupled plasma mass spectrometry: A review.

    Science.gov (United States)

    Cao, Liguo; Bu, Wenting; Zheng, Jian; Pan, Shaoming; Wang, Zhongtang; Uchida, Shigeo

    2016-05-01

    Knowing the concentration and isotopic ratio of Pu in seawater is of critical importance for assessing Pu contamination and investigating oceanic processes. In recent decades, the concentration of (239+240)Pu in seawater, particularly for surface seawater, has presented an exponential decreasing trend with time; thus determination of Pu in seawater has become a challenge nowadays. Here, we have summarized and critically discussed a variety of reported analytical methods for Pu determination in seawater sample based on inductively coupled plasma mass spectrometry (ICP-MS) analytical technique for rapid ultra-trace detection of Pu. Generally, pretreatments for seawater sample include co-precipitation, valence adjustment and chemical separation and purification procedures, all of which are comprehensively reviewed. Overall, the selected anion-exchange, extraction resins and operation condition are important for decontamination of interference from matrix elements and achieving satisfactory chemical yields. In addition, other mass spectrometric and radiometric detections are briefly addressed and compared with the focus on assessing ICP-MS. Finally, we discuss some issues and prospects in determination and application of Pu isotopes in seawater samples for future research. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Laser ablation inductively coupled plasma mass spectrometry for the determination of trace elements in soil

    International Nuclear Information System (INIS)

    Lee Yiling; Chang Chaochiang; Jiang Shiuhjen

    2003-01-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been applied to the determination of Cr, Cu, Zn, Cd and Pb in soil samples. The dried soil powder was pressed into a pellet for LA-ICP-MS analysis. Triton X-100 was added to work as the modifier to enhance the ion signals. The influences of instrument operating conditions (LA and ICP-MS) and pellet preparation on the ion signals were reported. For Cr determination, the ICP-MS was operated under the dynamic reaction cell mode which alleviated the mass overlap interference. Standard addition method and isotope dilution method were used for the quantitation work. The powder sample was spiked with suitable amounts of element standards and/or enriched isotopes, well-mixed, dried and then pressed into a pellet for LA-ICP-MS analysis. This method has been applied to determine Cr, Cu, Zn, Cd and Pb in NIST SRM 2711 Montana soil and NIST SRM 2709 San Joaquin soil reference materials. The analysis results were in agreement with the certified values. The precision between sample replicates was better than 5% with LA-ICP-MS method. Detection limits estimated from standard addition curves were approximately 0.9, 2, 9, 0.7 and 0.3 ng g -1 for Cr, Cu, Zn, Cd and Pb, respectively

  15. Comparison of experimental methods for determination of the volumetric mass transfer coefficient in fermentation processes

    Energy Technology Data Exchange (ETDEWEB)

    Tobajas, M.; Garcia-Calvo, E. [Dept. de Ingenieria Quimica, Univ. de Alcala, Alcala de Henares (Spain)

    2000-05-01

    Mass transfer in bioreactors has been examined. In the present work, dynamic methods are used for the determination of K{sub L}a values for water, model media and a fermentation broth (Candida utilis) in an airlift reactor. The conventional dynamic method is applied at the end of the microbial process in order to avoid an alteration in the metabolism of the microorganisms. New dynamic methods are used to determine K{sub L}a in an airlift reactor during the microbial growth of Candida utilis on glucose. One of the methods is based on the continuous measurement of carbon dioxide production while the other method is based on the relationship between the oxygen transfer and biomass growth rates. These methods of determining K{sub L}a does not interfere with the microorganisms action. A theoretical mass transfer model has been used for K{sub L}a estimation for the systems described above. Some differences between calculated and measured values are found for fermentation processes due to the model is developed for two-phase air-water systems. Nevertheless, the average deviation between the predicted values and those obtained from the relationship between oxygen transfer and biomass production rates are lower than 25% in any case. (orig.)

  16. First one-line mass measurements at SHIPTRAP and mass determinations of neutron-rich Fr and Ra isotopes at ISOLTRAP

    International Nuclear Information System (INIS)

    Rahaman, M.S.

    2005-01-01

    SHIPTRAP is an ion trap facility behind the velocity lter SHIP at GSI/Darmstadt. Its aim are precision studies of transuranium nuclides produced in a fusion reaction and separated by SHIP. The current set-up for high-precision mass measurements consists of three main functional parts: (i) a gas cell for stopping the energetic ions from SHIP, (ii) radiofrequency quadrupole structures to cool and to bunch the ions extracted from the gas cell, and (iii) a superconducting magnet with two cylindrical Penning traps at a eld strength of 7 T. In this work the Penning trap system has been installed and extensively characterized. The rst on-line mass measurements of short-lived nuclides were carried out and the masses of 147 Er and 148 Er could be experimentally determined for the rst time. Here a relative mass uncertainty of δm/m of about 1 x 10 -6 was achieved. Furthermore the masses of heavy neutron-rich 229-232 Ra and 230 Fr isotopes have been determined with a relative mass uncertainty of about 1 x 10 -7 with the ISOLTRAP mass spectometer at ISOLDE/CERN. The isotope 232 Ra is the heaviest unstable nuclide ever investigated with a Penning trap. Underlying nuclear structure effects of these nuclides far from β-stability were studied by a comparison of the resulting two-neutron separation energies S 2n with those given by the theoretical Infinite Nuclear Mass model. (orig.)

  17. Patterns and determinants of antenatal care utilization: analysis of national survey data in seven countdown countries

    Directory of Open Access Journals (Sweden)

    Ghada Saad–Haddad

    2016-06-01

    Full Text Available Antenatal care (ANC is critical for improving maternal and newborn health. WHO recommends that pregnant women complete at least four ANC visits. Countdown and other global monitoring efforts track the proportions of women who receive one or more visits by a skilled provider (ANC1+ and four or more visits by any provider (ANC4+. This study investigates patterns of drop–off in use between ANC1+ and ANC4+, and explores inequalities in women’s use of ANC services. It also identifies determinants of utilization and describes countries’ ANC–related policies, and programs.

  18. Linking diverse nutrient patterns to different water masses within anticyclonic eddies in the upwelling system off Peru

    Science.gov (United States)

    Saranga José, Yonss; Dietze, Heiner; Oschlies, Andreas

    2017-03-01

    Ocean eddies can both trigger mixing (during their formation and decay) and effectively shield water encompassed from being exchanged with ambient water (throughout their lifetimes). These antagonistic effects of eddies complicate the interpretation of synoptic snapshots typically obtained by ship-based oceanographic measurement campaigns. Here we use a coupled physical-biogeochemical model to explore biogeochemical dynamics within anticyclonic eddies in the eastern tropical South Pacific Ocean. The goal is to understand the diverse biogeochemical patterns that have been observed at the subsurface layers of the anticyclonic eddies in this region. Our model results suggest that the diverse subsurface nutrient patterns within eddies are associated with the presence of water masses of different origins at different depths.

  19. Device for determining element contents of lignite mass flows by activation analysis

    International Nuclear Information System (INIS)

    Goeldner, R.; Maul, E.; Rose, W.; Wagner, D.

    1987-01-01

    A simple device is presented, apt for continuous operation, to determine the element contents of bulk goods of flowable materials with a suitable granularity, in particular of lignite mass flows to assess the coal quality. Several kilograms of samples can be reproducibly dosed and homogeneously activated by a device consisting of a shielding container with activation chamber and radiation source, a measuring unit with detectors, and a source container, and characterized by a blade wheel in the activation chamber which causes the dosing and homogeneous activation of the sample

  20. Experimental determination of isotope enrichment factors – bias from mass removal by repetitive sampling

    DEFF Research Database (Denmark)

    Buchner, Daniel; Jin, Biao; Ebert, Karin

    2017-01-01

    to account for mass removal and for volatilization into the headspace. In this study we use both synthetic and experimental data to demonstrate that the determination of ε-values according to current correction methods is prone to considerable systematic errors even in well-designed experimental setups....... Application of inappropriate methods may lead to incorrect and inconsistent ε-values entailing misinterpretations regarding the processes underlying isotope fractionation. In fact, our results suggest that artifacts arising from inappropriate data evaluation might contribute to the variability of published ε...

  1. Thallium determination in reference materials by isotope dilution mass spectrometry (IDMS) using thermal ionization

    International Nuclear Information System (INIS)

    Waidmann, E.; Hilpert, K.; Stoeppler, M.

    1990-01-01

    Using Isotope Dilution Mass Spectrometry (IDMS) with thermal ionization, thallium concentrations were determined in reference materials from NIST and BCR, from other sources, and reference materials from the German Environmental Specimen Bank 203 Tl spike solution is applied for the isotope dilution technique. Thallium concentrations in the investigated materials range from 2.67 μg Tl.kg -1 to 963 μg Tl.kg -1 with a relative standard deviation from 0.14 to 10%. The detection limit was 0.1 ng thallium for this work. (orig.)

  2. Mass spectrometric determination of the thermodynamic excess properties of ternary Fe-Co-Cr melts

    International Nuclear Information System (INIS)

    Schmidt, Harald; Tomiska, Josef

    2004-01-01

    Computer-aided Knudsen cell mass spectrometry is used for the thermodynamic investigations on ternary Fe-Co-Cr melts over the entire range of composition. The thermodynamic mixing behavior has been determined by means of the 'digital intensity-ratio' (DIR) method. The ternary thermodynamically adapted power (TAP) series concept is used for the algebraic representation of the molar excess properties. The corresponding TAP parameters, and the values of the molar excess quantities Z E (T, x) (Z is the Gibbs energy G, heat of mixing H, entropy S) as well as the thermodynamic activities of all three constituents at 1950 K are presented

  3. Electrospray ionization mass spectrometric method for the determination of cannabinoid precursors

    DEFF Research Database (Denmark)

    Hansen, H.H.; Hansen, S.H.; Bøjrnsdottir, I.

    1999-01-01

    electrospray ionization mass spectrometry (ESI-MS). The procedure provides complete positioning of all acyl and alkenyl groups contained in each NAPE species. The calibration curve for standard NAPE was linear over the range 100 fmol-50 pmol (0.1-50 ng) per injection. The lower limit of detection (signal......-to-noise ratio of 3) was 100 fmol, implying that this method is superior to previous methods for the determination of NAPE. These results suggest that this ESI-MS method can be used to identify and quantify NAPE species in mammalian tissues and provide information on the corresponding NAEs to be released from...

  4. A radiometric mass flow probe for determining the screen overflow of potato harvesters

    International Nuclear Information System (INIS)

    Glaeser, M.

    1976-01-01

    A radiometric conveyor balance based on the principle of gamma attenuation is described. Being independent on the electric network, it is suitable for nonstationary operation. Cesium 137 is used as radiation source. Detection is performed through a special system of halogen and ordinary counters. First tests were made under field conditions in order to determine the passing mass (potatoes and soil) and to find out the sieving capacity of the potato harvesters. The maximum throughput is about 50 tons per hour. Potatoes and soil up to about 2 tons may be weighed by means of this balance with a relative error of +- 3.5 %. (author)

  5. Quantitative mass fragmentographic determination of unlabeled and deuterium-labeled propoxyphene in plasma

    International Nuclear Information System (INIS)

    Sullivan, H.R.; McMahon, R.E.

    1977-01-01

    A quantitative gas chromatographic-mass spectrometric method for determination of plasma levels of d-propoxyphene has been developed by using d-propoxyphene-benzyl-d 7 as internal standard. Steady-state pharmacokinetics were studied in a dog by orally administering d-propoxyphene-d 0 for 19 days and d-propoxyphene-d 2 on the 20th day, and monitoring the plasma levels of both compounds and the ratio for 48 hours. It was established that the use of propoxyphene-d 2 did not lead to an isotope effect

  6. Determination of rare earth elements in tomato plants by inductively coupled plasma mass spectrometry techniques.

    Science.gov (United States)

    Spalla, S; Baffi, C; Barbante, C; Turetta, C; Turretta, C; Cozzi, G; Beone, G M; Bettinelli, M

    2009-10-30

    In recent years identification of the geographical origin of food has grown more important as consumers have become interested in knowing the provenance of the food that they purchase and eat. Certification schemes and labels have thus been developed to protect consumers and genuine producers from the improper use of popular brand names or renowned geographical origins. As the tomato is one of the major components of what is considered to be the healthy Mediterranean diet, it is important to be able to determine the geographical origin of tomatoes and tomato-based products such as tomato sauce. The aim of this work is to develop an analytical method to determine rare earth elements (RRE) for the control of the geographic origin of tomatoes. The content of REE in tomato plant samples collected from an agricultural area in Piacenza, Italy, was determined, using four different digestion procedures with and without HF. Microwave dissolution with HNO3 + H2O2 proved to be the most suitable digestion procedure. Inductively coupled plasma quadrupole mass spectrometry (ICPQMS) and inductively coupled plasma sector field plasma mass spectrometry (ICPSFMS) instruments, both coupled with a desolvation system, were used to determine the REE in tomato plants in two different laboratories. A matched calibration curve method was used for the quantification of the analytes. The detection limits (MDLs) of the method ranged from 0.03 ng g(-1) for Ho, Tm, and Lu to 2 ng g(-1) for La and Ce. The precision, in terms of relative standard deviation on six replicates, was good, with values ranging, on average, from 6.0% for LREE (light rare earth elements) to 16.5% for HREE (heavy rare earth elements). These detection limits allowed the determination of the very low concentrations of REE present in tomato berries. For the concentrations of REE in tomato plants, the following trend was observed: roots > leaves > stems > berries. Copyright 2009 John Wiley & Sons, Ltd.

  7. Differences in Dietary Patterns among College Students According to Body Mass Index

    Science.gov (United States)

    Brunt, Ardith; Rhee, Yeong; Zhong, Li

    2008-01-01

    Objective and Participants: The authors surveyed 557 undergraduate students aged 18-56 years to assess weight status, health behaviors, and dietary variety. Methods: They used body mass index (BMI) to divide students into 4 weight categories: underweight (BMI less than 19 kg/m2), healthy weight (19 kg/m2 to 24.99 kg/m2), overweight (25 kg/m2 to…

  8. Violent mass shootings in Sweden from 1960 to 1995: profiles, patterns, and motives.

    Science.gov (United States)

    Lindquist, O; Lidberg, L

    1998-03-01

    During the past few decades, violent mass shooting in Sweden has increased rapidly. In the 36 years between 1960 and 1995, fourteen such occasions were recorded, during which 32 people were killed and 57 were wounded. The 14 offenders were men between the ages of 17 and 61 years. In the 20 years from 1960 to 1979, five shootings were committed by five offenders, leaving 10 dead and 13 wounded; in the 16 years between 1980 and 1995, there were nine different shootings committed by nine offenders, with 22 dead and 44 wounded. Seven of the shootings were classified as mass shootings, six as spree shootings, and one as a serial shooting. In all but four of these cases, the firearms used were illegal weapons. The four legal firearms belonged to an unemployed young laborer, an officer, a former United Nations (U.N.) soldier, and a member of the Swedish military volunteer corps. Of those killed, 68.8% were strangers to the offender; among the wounded, the corresponding figure was 89.5%. Profiles of the offenders and of the victims were studied. The psychiatric diagnoses among the offenders and the measures taken to prevent the increase in mass shooting in Sweden are presented.

  9. Spatial Pattern Determination of Biodiversity Threats at Landscape Level (Case Study: Golestan Province

    Directory of Open Access Journals (Sweden)

    R. Mirzaei

    2015-06-01

    Full Text Available Mapping spatial patterns of potential biodiversity threats is one of the important steps for effective conservation planning and activities. To determine the spatial patterns of threats in Golestan province, 12 criteria in four main groups including structural (fractal coefficient of perimeter, circularity ratio of area, average slope, compositional aspects of biodiversity (presence of species at risk, non-biological threats (distance to city, distance to village, distance to road, distance to infrastructure, distance to agricultural land, soil pollution, risk of fire and isolation (Nearest Neighbor Index were used. These data layers were digitized in GIS environment and were weighted through Analytical Hierarchy Process. A weighted linear combination was then used to map the spatial pattern of biodiversity threats in the province. Compositional aspect (0.59, non-biological threats (0.23, isolation (0.11, and structural aspect (0.07 were relatively weighted in the order of importance. Central parts of the province and patches in the northern and southern parts were recognized to be more exposed to biodiversity threats. The central parts of the province were mostly threatened by urban, industrial, road and agricultural development, whereas the northern and southern parts were recognized as areas of conservation importance having a variety of threatened birds.

  10. Lethal body concentrations and accumulation patterns determine time-dependent toxicity of cadmium in soil arthropods

    Energy Technology Data Exchange (ETDEWEB)

    Crommentuijn, T.; Doodeman, C.J.A.M.; Doornekamp, A.; Pol, J.J.C. van der; Bedaux, J.J.M.; Gestel, C.A.M. van (Vrije Univ., Amsterdam (Netherlands))

    1994-11-01

    Time-dependent toxicity in bioassays is usually explained in terms of uptake and elimination kinetics of the toxicant. By comparing different species with essentially different accumulation kinetics, a firm test of this concept may be made. This article compares the sensitivity of six soil arthropods, the collembolans Orchesella cincta and Tomocerus minor, the oribatid mite Platynothrus peltifer, the isopods Porcellio scaber and Oniscus asellus, and the diplopod Cylindroiulus britannicus, when exposed to cadmium in the food. Survival was determined at various time intervals; accumulation of cadmium in the animals was measured at one time interval. Kinetic-based toxicity models were fitted to the data, and estimates were obtained for lethal body concentration, uptake rate constant, elimination rate constant, and ultimate LC50. Two different accumulation patterns could be discerned; these were correlated with time-survival relationships. One, species that have the possibility to eliminate cadmium will reach an equilibrium for the internal concentration and also an ultimate LC50. Two, species that are unable to eliminate cadmium but store it in the body will have an ultimate LC50 equal to zero. For these species the time in which the lethal body concentration is reached is more important. Taxonomically related species appeared to have comparable accumulation patterns, but lethal body concentrations differed. It is concluded that knowledge of the accumulation pattern is indispensable for the evaluation of species' sensitivities to toxicants.

  11. Determination of the Electron Neutrino Mass from Experiments on Electron-Capture Beta-Decay (EC)

    CERN Multimedia

    2002-01-01

    The aim of the programme is to measure the electron-neutrino mass, for which at present an upper limit of 500~eV is known. \\\\ \\\\ The experiment studies the shape of the internal bremsstrahlung spectrum in electron-capture near its upper end-point and deduces a mass from small shape changes completely analogous to those in the well-known determination of the electron antineutrino mass in the tritium beta-minus decay. \\\\ \\\\ In a low-energy bremsstrahlung process, the capture takes place from a virtual S state associated with a radiative P~@A~S electromagnetic transition, and the resonant nature of the process leads to important enhancements of the photon intensities at low energy, in particular near the resonance energies co (X-rays). This effect gives this type of experiment a chance to compete with experiments on continuous beta spectra. \\\\ \\\\ The programme concentrates on two long-lived isotopes: \\\\ \\\\ 1)~~|1|6|3Ho. The Q value for this isotope has been found to be 2.6-2.7 keV. A detector specially construct...

  12. Mass spectrometer determinations of solar wind He, Ne, and Ar and radiation belt He

    International Nuclear Information System (INIS)

    Warasila, R.L.

    1976-01-01

    A unique mass spectrometer system was built and used to measure He, Ne, and Ar abundances and isotopic ratios in various samples of spacecraft that have been exposed to the space environment. The Apollo 12 mission brought back sections of the Surveyor 3 vehicle suitable for mass spectrometric studies of implanted solar wind and solar cosmic ray particles. Using the mass spectrometer, a 4 He flux of 6-8 x 10 6 ions/cm 2 --sec was measured, and in addition 4 He/ 3 He = 2700 +- 50; 4 He/ 20 Ne = 410 + 30; 20 Ne/ 22 Ne = 13.5 +- 0.2; 20 Ne/ 36 Ar = 24.5 +- 2.5; and 36 Ar/ 38 Ar = 5.41 +- 0.20 isotopic abundances were measured. An upper limit for the flux of SCR 3 He in the 10-20 MeV/nucleon range was also determined, for the thirty-one month exposure period. In the radiation belt environment, 3 He was found in the aluminum antenna housing from the recovered second stage of a pre-Apollo Saturn test flight launched January 28, 1964 and returned to earth on April 28, 1966. The amount of 3 He found was about 6 x 10 -10 cc(STP)/cm 2 with a 4 He/ 3 He ratio of 145 or less. The 3 He was shown to come from the lower radiation belt as all other sources of 3 He were orders of magnitude lower than the observed value

  13. Simultaneous determination of ramipril, ramiprilat and telmisartan in human plasma using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Gupta, V K; Jain, Rajeev; Lukram, Ojitkumar; Agarwal, Shilpi; Dwivedi, Ashish

    2011-01-15

    A rapid and sensitive liquid chromatography tandem mass spectrometry method has been developed and validated for the simultaneous determination of ramipril, ramiprilat and telmisartan in human plasma. The solid-phase extraction technique was used for the extraction of ramipril, ramiprilat and telmisartan from human plasma. Trandolaprilat and hydrochlorothiazide were used as the internal standards (ISs). Chromatography was performed on a Hypurity C18, 5 μm, 50 mm × 4.6mm column, with the mobile phase consisting of ammonium acetate and acetonitrile (in a 20:80 ratio), followed by detection using mass spectrometry. The method involves a simple reversed isocratic chromatography condition and mass spectrometry detection, which enables detection at sub-nanogram levels. The method was validated and the lower limit of quantification for ramipril, ramiprilat and telmisartan was found to be 0.1 ng mL(-1), 0.1 ng mL(-1) and 2 ng mL(-1), respectively. The mean recovery for ramipril, ramiprilat and telmisartan ranged from 90.1 to 104.1%. This method increased the sensitivity and selectivity; resulting in high-throughput analysis of ramipril, ramiprilat and telmisartan using two different ISs in a single experiment for bioequivalence studies, with a chromatographic run time of 1.5 min only. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Applications of Tandem Mass Spectrometry in the Structure Determination of Permethylated Sialic Acid-containing Oligosaccharides

    International Nuclear Information System (INIS)

    Yoo, Eun Sun; Yoon, In Mo

    2005-01-01

    Sets of sialic acid-containing trisaccharides having different internal and terminal linkages have been synthesized to develop a sensitive method for analysis of the reducing terminal linkage positions. The trisaccharides, sialyl(α 2-3)Gal(β 1-3)GalNAc and sialyl(α 2-3)Gal(β 1-X)GlcNAc where X=3, 4 and 6, were synthesized and examined using electrospray ionization (ESI)-collision induced dissociation (CID) tandem mass spectrometry (MS/MS). The compounds chosen for this study are related to terminal groups likely to be found on polylactosamine-like glycoproteins and glycolipids which occur on the surface of mammalian cells. The purpose of this study is to develop tandem mass spectrometral methods to determine detailed carbohydrate structures on permethylated or partially methylated oligosaccharides for future applications on biologically active glycoconjugates and to exploit a faster method of synthesizing a series of structural isomeric oligosaccharides to be used for further mass spectrometry and instrumental analysis

  15. Determination of Nerve Agent Metabolites by Ultraviolet Femtosecond Laser Ionization Mass Spectrometry.

    Science.gov (United States)

    Hamachi, Akifumi; Imasaka, Tomoko; Nakamura, Hiroshi; Li, Adan; Imasaka, Totaro

    2017-05-02

    Nerve agent metabolites, i.e., isopropyl methylphosphonic acid (IMPA) and pinacolyl methylphosphonic acid (PMPA), were derivatized by reacting them with 2,3,4,5,6-pentafluorobenzyl bromide (PFBBr) and were determined by mass spectrometry using an ultraviolet femtosecond laser emitting at 267 and 200 nm as the ionization source. The analytes of the derivatized compounds, i.e., IMPA-PFB and PMPA-PFB, contain a large side-chain, and molecular ions are very weak or absent in electron ionization mass spectrometry. The use of ultraviolet femtosecond laser ionization mass spectrometry, however, resulted in the formation of a molecular ion, even for compounds such as these that contain a highly bulky functional group. The signal intensity was larger at 200 nm due to resonance-enhanced two-photon ionization. In contrast, fragmentation was suppressed at 267 nm (nonresonant two-photon ionization) especially for PMPA-PFB, thus resulting in a lower background signal. This favorable result can be explained by the small excess energy in ionization at 267 nm and by the low-frequency vibrational mode of a bulky trimethylpropyl group in PMPA.

  16. Hormonal and lifestyle determinants of appendicular skeletal muscle mass in men: the MINOS study.

    Science.gov (United States)

    Szulc, Pawel; Duboeuf, François; Marchand, François; Delmas, Pierre D

    2004-08-01

    Aging-related sarcopenia is characterized by a loss of muscle mass and strength and increased fatigability. However, studies of its determinants in elderly men are scarce. We investigated risk factors for sarcopenia in a large cohort of men. We analyzed 845 men aged 45-85 y who belonged to the MINOS cohort. Lifestyle factors (physical activity, tobacco smoking, alcohol intake, caffeine intake) were evaluated by using a standardized questionnaire. Appendicular skeletal muscle mass (ASM) was estimated by using dual-energy X-ray absorptiometry. The relative appendicular skeletal muscle mass index (RASM) was calculated as ASM/body height(2.3). Apparent free testosterone concentration (AFTC) and free testosterone index (FTI) were calculated on the basis of concentrations of total testosterone and sex hormone-binding globulin. RASM decreased with age (r = -0.29, P values for AFTC, FTI, or 25-hydroxycholecalciferol [25(OH)D] were >2 SDs below the mean for young men had significantly lower RASM than did men with higher values. Men with sarcopenia, defined as the lowest quartile of RASM in the studied cohort (normal RASM, weighed significantly less, smoked more, and spent significantly less time on leisure-time activities. Sarcopenic men also had lower values for testosterone, AFTC, FTI, and 25(OH)D. In elderly men, low physical activity, tobacco smoking, thinness, low testosterone (AFTC and FTI), and decreased 25(OH)D concentrations are risk factors for sarcopenia.

  17. Determination of zinc stable isotopes in biological materials using isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Patterson, K.Y.; Veillon, Claude

    1992-01-01

    A method is described for using isotope dilution to determine both the amount of natural zinc and enriched isotopes of zinc in biological samples. Isotope dilution inductively coupled plasma mass spectrometry offers a way to quantify not only the natural zinc found in a sample but also the enriched isotope tracers of zinc. Accurate values for the enriched isotopes and natural zinc are obtained by adjusting the mass count rate data for measurable instrumental biases. Analytical interferences from the matrix are avoided by extracting the zinc from the sample matrix using diethylammonium diethyldithiocarbamate. The extraction technique separates the zinc from elements which form interfering molecular ions at the same nominal masses as the zinc isotopes. Accuracy of the method is verified using standard reference materials. The detection limit is 0.06 μg Zn per sample. Precision of the abundance ratios range from 0.3-0.8%. R.S.D. for natural zinc concentrations is about 200-600 μg g -1 . The accuracy and precision of the measurements make it possible to follow enriched isotopic tracers of zinc in biological samples in metabolic tracer studies. (author). 19 refs.; 1 fig., 4 tabs

  18. Determination of deuterium in metal by vacuum fusion-mass spectrometric method

    International Nuclear Information System (INIS)

    Wada, Yukio; Akiyama, Shigeo; Ochiai, Ken-ichi; Asakura, Toshiro; Tsutsumi, Ken-ichi

    1976-01-01

    A specimen of deuterium-enriched Zircaloy was prepared to study a method for the determination of deuterium in metal. The measuring apparatus consists of vacuum fusion section (10 -5 -10 -4 Torr), gas extracting and collecting section, the section of introducing both standard D 2 and HD gases into a gas holder, and mass spectrometric analysis section. The deuterium in Zircaloy can be extracted by 100% for 5 min. at 1600 0 C. The main components of the extracted gas are H 2 , D 2 , HD, CO, H 2 O and N 2 . Deuterium is determined by the calculation from the determinations of D 2 and HD. The amounts of D 2 and HD gases in the specimen were obtained from the calibration curve prepared and the spectrum intensity of D 2 + and HD + resulted from specimen analysis. As a result of the analysis of D 2 -enriched Zircaloy, it has been found that the precision of the determination is within the coefficient variation of about 3% for the extracted D 2 gas amount of 10 -3 -10 -2 ml (STP), including the deuterium segregation in the specimen, and the determination limit was 1 x 10 -5 ml (STP). (Kobatake, H.)

  19. Determining neutrino mass hierarchy from electron disappearance at a low energy neutrino factory

    International Nuclear Information System (INIS)

    Raut, Sushant K.

    2013-01-01

    Reactor neutrino experiments have recently measured the value of θ 13 , to be non-zero and moderately large. This makes the determination of the neutrino mass hierarchy possible. However, our lack of knowledge of δ CP results in a parameter degeneracy, which makes this task difficult. The electron neutrino disappearance probability does not depend on δ CP . Therefore, in principle, it is possible to determine the hierarchy independently of δ CP using this channel. Previous studies of neutrino factories have not considered this channel, because the effect of systematics in electron disappearance is substantial. However, we show that for the moderately large value of θ 13 measured, hierarchy determination is possible in spite of systematic effects. We consider a low energy neutrino factory (LENF) setup with a totally active scintillator detector (TASD) with charge-identification. We optimize the setup in muon energy and baseline, for different allowed values of θ 13 and runtime. We find that a LENF with baseline of around 1300 km and muon energy around 3-4 GeV is well suited for hierarchy determination. For the RENO best-fit value of θ 13 , this setup can determine the hierarchy at 5ω, for all values of δ CP and for both hierarchies. (author)

  20. Direct isotope determination of isotopically labelled lipids by field desorption mass spectrometry

    International Nuclear Information System (INIS)

    Lehmann, W.D.; Kessler, M.

    1982-01-01

    Lipids labelled with deuterium or carbon-14 have been investigated by field desorption mass spectrometry for determination of their degree of labelling. This application is demonstrated for free fatty acids, cholesterol, cholesteryl esters, triglycerides, and L-α-phosphatidylcholines. Comparison of the molecular ion groups of the non-labelled and of the labelled compounds enables a fast and reliable determination of the degree of labelling. For multiply labelled compounds the label distribution is also obtained from the molecular ion group. In addition, for cholesteryl esters and for phosphatidylcholines structurally significant fragment ions provide information about the position of the label. Several hundred nanograms of the compound are typically required for a single analysis with a relative standard error of 0.5-2% in the value calculated for atom% hydrogen-2 or for the specific carbon-14 activity. (orig.) [de

  1. Hot vacuum extraction-isotopic dilution mass spectrometry for determination of hydrogen isotopes in zircaloys

    International Nuclear Information System (INIS)

    Shi, Y.; Leeson, P.K.; Wilkin, D.; Britton, A.; Macleod, R.

    2016-01-01

    A hot vacuum extraction-isotope dilution mass spectrometry (HVE-IDMS) was studied for determination of hydrogen isotopes in zirconium metal and alloys as nuclear reactor materials. A theoretical assessment of the completeness of the extraction of hydrogen isotopes under the chosen condition was carried out based on the hydrogen and deuterium solubility data for zirconium. The optimal isotopic spiking condition for conventional IDMS was further explored for the special case IDMS where the isotope abundance of the samples is varied and non-natural. Applying the optimal conditions, the accurate IDMS determination was realized. The agreement between the measured values and the certified or prepared values of standard reference materials and homemade standard materials validate the method developed. (author)

  2. Determination of trimethoprim in tissues using liquid chromatography-thermospray mass spectrometry.

    Science.gov (United States)

    Cannavan, A; Hewitt, S A; Floyd, S D; Kennedy, D G

    1997-11-01

    A method is described for the determination of the antibacterial drug trimethoprim in tissues. Minced tissue is homogenised with chloroform-acetone (1 + 1 v/v), filtered, and the filtrate evaporated to an oily residue using a rotary evaporator. The residue is redissolved in methanol-water-acetic acid (50 + 48.7 + 1.3 v/v) and any fats present are partitioned into hexane. The aqueous phase is analysed by liquid chromatography-thermospray mass spectrometry in positive mode with the protonated molecular ion at m/z 291 being monitored. Recoveries ranged between 60% in liver and 79% in muscle. The limit of determination was 25 micrograms kg-1 and the limit of detection was approximately 4 micrograms kg-1. The method is suitable for monitoring tissues taken under national surveillance schemes for veterinary drug residues.

  3. Determination of left ventricular function parameters and myocardial mass: comparison of MRI and EBT

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Wiese, T.H.; Lembcke, A.; Taupitz, M.; Hamm, B.; Borges, A.; Zytowski, M.

    2000-01-01

    Purpose: Comparative volumetric assessment of the left ventricle by magnetic resonance imaging (MRI) and electron beam tomography (EBT) in patients with ischemic and dilated cardiac disease. Methods: Thirty-two patients underwent cine MRI and EBT in the multislice mode. All studies were triggered to the ECG. Left ventricular ejection fraction (EF), enddiastolic (EDV) and endsystolic volume (ESV), and myocardial mass (MM) were determined by 3D-volumetry by MRI and EBT and results were compared. Results: The correlation between MRI and EBT for EF, EDV, ESV, and MM were r=0.86, r=0.95, r=0.95, and r=0.93, respectively. Conclusions: There is an excellent correlation between MRI and EBT in determining left-ventricular parameters. Both methods are suitable for volumetric assessment of the left ventricie. (orig.) [de

  4. The determination of long life radionuclides by means of sector field ICP mass spectrometry

    International Nuclear Information System (INIS)

    Kerl, W.; Becker, J.S.; Dietze, H.J.; Dannecker, W.

    1996-01-01

    Different analytical processes for determining long life radionuclides by means of double-focussing sector field ICP mass spectrometry are described. In determining long life radionuclides by means of ICP-MS, on the one hand the analytical problem areas are in the interference of isobaric atom or molecule ions (eg: 151 Eu + - 151 Sm + , 79 Se + - 39 Ar 40 ArH + ) and on the other hand in the high detection limits when using commercial sample introduction systems (eg: For 129 I). An online coupling of HPLC and ICP-MS was built up for the separation of isobaric atom ions and was tested for the separation of isobaric atom ions and was tested for its efficiency in the separation of lanthanides. Special sample introduction systems for ICP-MS were developed for the analysis of 129 I, by which the sensitivity of detection can be appreciably improved compared to commercial sample introduction systems. (orig.) [de

  5. Chemical Evolution of Groundwater Near a Sinkhole Lake, Northern Florida: 2. Chemical Patterns, Mass Transfer Modeling, and Rates of Mass Transfer Reactions

    Science.gov (United States)

    Katz, Brian G.; Plummer, L. Niel; Busenberg, Eurybiades; Revesz, Kinga M.; Jones, Blair F.; Lee, Terrie M.

    1995-06-01

    Chemical patterns along evolutionary groundwater flow paths in silicate and carbonate aquifers were interpreted using solute tracers, carbon and sulfur isotopes, and mass balance reaction modeling for a complex hydrologic system involving groundwater inflow to and outflow from a sinkhole lake in northern Florida. Rates of dominant reactions along defined flow paths were estimated from modeled mass transfer and ages obtained from CFC-modeled recharge dates. Groundwater upgradient from Lake Barco remains oxic as it moves downward, reacting with silicate minerals in a system open to carbon dioxide (CO2), producing only small increases in dissolved species. Beneath and downgradient of Lake Barco the oxic groundwater mixes with lake water leakage in a highly reducing, silicate-carbonate mineral environment. A mixing model, developed for anoxic groundwater downgradient from the lake, accounted for the observed chemical and isotopic composition by combining different proportions of lake water leakage and infiltrating meteoric water. The evolution of major ion chemistry and the 13C isotopic composition of dissolved carbon species in groundwater downgradient from the lake can be explained by the aerobic oxidation of organic matter in the lake, anaerobic microbial oxidation of organic carbon, and incongruent dissolution of smectite minerals to kaolinite. The dominant process for the generation of methane was by the CO2 reduction pathway based on the isotopic composition of hydrogen (δ2H(CH4) = -186 to -234‰) and carbon (δ13C(CH4) = -65.7 to -72.3‰). Rates of microbial metabolism of organic matter, estimated from the mass transfer reaction models, ranged from 0.0047 to 0.039 mmol L-1 yr-1 for groundwater downgradient from the lake.

  6. Fast mass spectrometry-based enantiomeric excess determination of proteinogenic amino acids.

    Science.gov (United States)

    Fleischer, Heidi; Thurow, Kerstin

    2013-03-01

    A rapid determination of the enantiomeric excess of proteinogenic amino acids is of great importance in various fields of chemical and biologic research and industries. Owing to their different biologic effects, enantiomers are interesting research subjects in drug development for the design of new and more efficient pharmaceuticals. Usually, the enantiomeric composition of amino acids is determined by conventional analytical methods such as liquid or gas chromatography or capillary electrophoresis. These analytical techniques do not fulfill the requirements of high-throughput screening due to their relative long analysis times. The method presented allows a fast analysis of chiral amino acids without previous time consuming chromatographic separation. The analytical measurements base on parallel kinetic resolution with pseudoenantiomeric mass tagged auxiliaries and were carried out by mass spectrometry with electrospray ionization. All 19 chiral proteinogenic amino acids were tested and Pro, Ser, Trp, His, and Glu were selected as model substrates for verification measurements. The enantiomeric excesses of amino acids with non-polar and aliphatic side chains as well as Trp and Phe (aromatic side chains) were determined with maximum deviations of the expected value less than or equal to 10ee%. Ser, Cys, His, Glu, and Asp were determined with deviations lower or equal to 14ee% and the enantiomeric excess of Tyr were calculated with 17ee% deviation. The total screening process is fully automated from the sample pretreatment to the data processing. The method presented enables fast measurement times about 1.38 min per sample and is applicable in the scope of high-throughput screenings.

  7. Cell-patterned glass spray for direct drug assay using mass spectrometry

    International Nuclear Information System (INIS)

    Wu, Jing; Wang, Shiqi; Chen, Qiushui; Jiang, Hao; Liang, Shuping; Lin, Jin-Ming

    2015-01-01

    In this work, the establishment of a glass spray mass spectrometry (GS-MS) platform for direct cell-based drug assay was described. Cell co-culture, drug-induced cell apoptosis, proliferation analysis and intracellular drug absorption measurement were performed simultaneously on this specifically designed platform. Two groups of co-cultured cells (NIH-3T3/HepG2 and HepG2/MCF-7) were cultivated and they showed high viability within 3 days. The biocompatibility of the platform facilitated the subsequent bioassays, in which, cyclophosphamide (CPA) and genistein were used as the model drugs. The distinctions of cell apoptosis and proliferation between the mono-cultured and co-cultured cells were clearly observed and well explained by in situ GS-MS measurements. A satisfactory linearity of the calibration curve between the relative MS intensity and CPA concentrations was obtained using stable isotope labeling method (y = 0.16545 + 0.0985x, R"2 = 0.9937). The variations in the quantity of absorbed drug were detected and the results were consistent with the concentration-dependence of cell apoptosis. All the results demonstrated that direct cell-based drug assay could be performed on the stable isotope labeling assisted GS-MS platform in a facile and quantitative manner. - Highlights: • A versatile glass spray mass spectrometry (GS-MS) platform for direct cell-based drug assay was developed in this paper. • It has characteristics of the atmospheric pressure ionization method. • It is multifunctional for cell co-culture, bioassays, qualitative and quantitative intracellular drug absorption measurement. • GS-MS has the potential to increase the use of mass spectrometry in biological analysis.

  8. Use patterns, excretion masses and contamination profiles of antibiotics in a typical swine farm, south China.

    Science.gov (United States)

    Zhou, Li-Jun; Ying, Guang-Guo; Zhang, Rui-Quan; Liu, Shan; Lai, Hua-Jie; Chen, Zhi-Feng; Yang, Bin; Zhao, Jian-Liang

    2013-04-01

    The objective of this study was to screen the occurrence of 50 antibiotics in a typical swine farm in southern China, which includes animal feeds, waste collection and treatment systems (lagoons and anaerobic digesters), and receiving environments (vegetable fields, streams, and private wells). Nine antibiotics were found in the feeds for different stages of the development of pigs in the swine farm, at concentrations ranging from 2.37 ± 0.16 ng g(-1) (sulfamethazine) to 61 500 ± 11 900 ng g(-1) (bacitracin). 11, 17 and 15 target compounds were detected in feces, flush water, and suspended particles in the swine farm, respectively. Based on the survey of feeds and animal waste from the farm, chlortetracycline, tetracycline, bacitracin and florfenicol in the feces, flush water and suspended particles mainly originated from the feeds, while most sulfonamides, including doxycycline, oxytetracycline, fluoroquinolones, macrolides and trimethoprim, were mainly from injection and other oral routes. The daily excretion masses of antibiotics per pig calculated based on animal waste had the following order: sows (48.3 mg per day per pig), piglets (18.9 mg per day per pig), growing pigs (7.01 mg per day per pig) and finishing pigs (1.47 mg per day per pig), indicating that the usage of antibiotics (type and dosage) and excretion masses are related to the growth stage of pigs. Chlortetracycline and bacitracin are the main contributors to the total excretion mass of antibiotics from pigs at different stages of development in the farm. The waste treatment system (lagoons and anaerobic digesters) was found to be ineffective in the elimination of antibiotics. The detection of some antibiotics in the surrounding environments of the farm (the well water, stream water and vegetable field soil) was a reflection of pollution from the swine farm.

  9. Measuring rural allied health workforce turnover and retention: what are the patterns, determinants and costs?

    Science.gov (United States)

    Chisholm, Marita; Russell, Deborah; Humphreys, John

    2011-04-01

    To measure variations in patterns of turnover and retention, determinants of turnover, and costs of recruitment of allied health professionals in rural areas. Data were collected on health service characteristics, recruitment costs and de-identified individual-level employment entry and exit data for dietitians, occupational therapists, physiotherapists, podiatrists, psychologists, social workers and speech pathologists employed between 1 January 2004 and 31 December 2009. Health services providing allied health services within Western Victoria were stratified by geographical location and town size. Eighteen health services were sampled, 11 participated. Annual turnover rates, stability rates, median length of stay in current position, survival probabilities, turnover hazards and median costs of recruitment were calculated. Analysis of commencement and exit data from 901 allied health professionals indicated that differences in crude workforce patterns according to geographical location emerge 12 to 24 months after commencement of employment, although the results were not statistically significant. Proportional hazards modelling indicated profession and employee age and grade upon commencement were significant determinants of turnover risk. Costs of replacing allied health workers are high. An opportunity for implementing comprehensive retention strategies exists in the first year of employment in rural and remote settings. Benchmarks to guide workforce retention strategies should take account of differences in patterns of allied health turnover and retention according to geographical location. Monitoring allied health workforce turnover and retention through analysis of routinely collected data to calculate selected indicators provides a stronger evidence base to underpin workforce planning by health services and regional authorities. © 2011 The Authors. Australian Journal of Rural Health © National Rural Health Alliance Inc.

  10. Leisure time physical activity in Saudi Arabia: prevalence, pattern and determining factors.

    Science.gov (United States)

    Amin, Tarek Tawfik; Al Khoudair, Ali Salah; Al Harbi, Mohammad Abdulwahab; Al Ali, Ahmed Radi

    2012-01-01

    Identification of reliable predictors of leisure time physical activity (LTPA) will enable healthcare providers to intervene and change the patterns of LTPA in the population to improve community health. The objectives of this study were to determine prevalence and pattern of LTPA among adult Saudis aged 18-65 years, and to define the socio-demographic determinants that correlate with LTPA in Al-Hassa, Saudi Arabia. A cross-sectional study of 2176 adult Saudis attending urban and rural primary health care centers were selected using a multistage proportionate sampling method. Participants were personally interviewed to gather information regarding socio-demographics, physical activity pattern using the Global Physical Activity Questionnaire (GPAQ). Physical activity (PA) in each domain was expressed in metabolic equivalents (METs). The median total METs minutes/week for LTPA for both genders was 256, higher for men (636 METs minutes/week) compared to women (249 METs minutes/week). Overall, only 19.8% of the total PA was derived from LTPA. Of the sampled population 50.0% reported doing no leisure activity. Using the cut off of 600 METs-minutes/day or 150 minutes of moderate intensity over 5 or more days/week, only 21.0% of the included sample were considered as being sufficiently active and 10.4% were in the high active category with beneficial health effects. Multivariate regression analysis showed that male, younger age (active in the LTPA domain. The prevalence and intensity of LTPA among the included sample demonstrated low levels. Nearly 80% of the included sample population did not achieve the recommended LTPA level with beneficial health effects. Female gender, urban residence and associated chronic diseases correlated with a low LTPA.

  11. The determination of time-stationary two-dimensional convection patterns with single-station radars

    International Nuclear Information System (INIS)

    Freeman, M.P.; Ruohoniemi, J.M.; Greenwald, R.A.

    1991-01-01

    At the present time, most ground-based radar estimations of ionospheric convection use observations from single-station facilities. This approach requires certain assumptions as to the spatial and/or temporal uniformity of the convection. In this paper the authors present a critical examination of the accuracy of these vector velocity determinations, using realistic modeled flow patterns that are time-stationary but not spatially uniform. They find that under certain circumstances the actual and inferred flow fields show considerable discrepancy, sometimes not even agreeing in the sense of flow direction. Specifically, they show that the natural curvature present in ionospheric convection on varying spatial scales can introduce significant error in the velocity estimate, particularly when the radius of curvature of the flow structure is less than or equal to the radar range to the scattering volume. The presence of flow curvature cannot be detected by radars which determine velocities from measurements in two viewing directions, and it might not be detected by radars using azimuth scanning techniques. Thus they argue that every effort should be made to measure the ionospheric convection by bidirectional or multidirectional observations of a common ionospheric volume and that a synthesis of coherent and incoherent radar observations from different sites is preferable to multidirectional single-station observations using either radar alone. These conclusions are applicable to any Doppler measurement technique and are equally valid for high-latitude wind patterns using Fabry-Perot interferometer techniques

  12. Effect of atmospheric flux uncertainties on the determination of the neutrino mass hierarchy

    Directory of Open Access Journals (Sweden)

    Sandroos Joakim

    2016-01-01

    Full Text Available The next generation of large-volume neutrino telescopes will include low-energy subarrays which will be able to measure neutrinos with energies of a few GeV. In this energy range the primary signal below the horizon is neutrinos created by cosmic ray interactions in the atmosphere. The measured event rate will depend on the neutrino mass hierarchy, allowing determination of this quantity to a significance level of about 3.5 sigma within a 5-year period, mostly limited by systematic uncertainties. We present here the impact of the uncertainties on the atmospheric neutrino flux normalization on the determination of the neutrino mass hierarchy. We suggest constraining the systematic uncertainties by including the downgoing neutrino sample, which will increase the significance. This work was performed using simulation data from the low-energy extension to the IceCube detector located at the geographic south pole, PINGU, and is relevant to a wide range of other experiments.

  13. Determination of fluspirilene in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionisation.

    Science.gov (United States)

    Swart, K J; Sutherland, F C; van Essen, G H; Hundt, H K; Hundt, A F

    1998-12-18

    An ultra-sensitive method for the determination of fluspirilene in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane/isoamyl alcohol, separated on a Phenomenex Luna C18 5 mu 150 x 2.1 mm column with a mobile phase consisting of methanol-water-acetic acid (600:400:1) at a flow-rate of 0.3 ml/min. Detection was achieved by a Finnigan Matt mass spectrometer (LCQ) at unit resolution in full scan mode scanning the product ion spectrum from m/z 130-500 and monitoring the transition of the protonated molecular ion at m/z 476.2, to the sum of the largest product ions m/z 371, 342 and 274 (MS-MS). Electrospray ionisation was used for ion production. The mean recovery for fluspirilene was 90% with a lower limit of quantification of 21.50 pg/ml using 1 ml plasma for extraction. This is the first chromatographic method described for the determination of fluspirilene in plasma that is accurate and sensitive enough to be used in pharmacokinetic studies.

  14. Food authenticity studies via multi-elemental and isotopic pattern using inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Katona, R.; Brunner, M.; Abranko, L.; Prohaska, T.; Stefanka, Z.

    2009-01-01

    Full text: The aim of our study has been the development of an analytical method based on Sr isotope and elemental fingerprint analysis for discriminating food samples from different geographical origin. Several types of foods were involved in the investigation representing different stages of food processing such as pulverized spicy paprika (sparsely processed food product) and wine samples (processed product). Independent inorganic mass spectrometric techniques like ICP-SFMS, ICP-CCMS, and MC-ICPMS were used for method validation and investigation of the geographical origin. The advantage and limitations of the developed methods are discussed critically. (author)

  15. Actigraphy-Derived Daily Rest-Activity Patterns and Body Mass Index in Community-Dwelling Adults.

    Science.gov (United States)

    Cespedes Feliciano, Elizabeth M; Quante, Mirja; Weng, Jia; Mitchell, Jonathan A; James, Peter; Marinac, Catherine R; Mariani, Sara; Redline, Susan; Kerr, Jacqueline; Godbole, Suneeta; Manteiga, Alicia; Wang, Daniel; Hipp, J Aaron

    2017-12-01

    To examine associations between 24-hour rest-activity patterns and body mass index (BMI) among community-dwelling US adults. Rest-activity patterns provide a field method to study exposures related to circadian rhythms. Adults (N = 578) wore an actigraph on their nondominant wrist for 7 days. Intradaily variability and interdaily stability (IS), M10 (most active 10-hours), L5 (least active 5-hours), and relative amplitude (RA) were derived using nonparametric rhythm analysis. Mesor, acrophase, and amplitude were calculated from log-transformed count data using the parametric cosinor approach. Participants were 80% female and mean (standard deviation) age was 52 (15) years. Participants with higher BMI had lower values for magnitude, RA, IS, total sleep time (TST), and sleep efficiency. In multivariable analyses, less robust 24-hour rest-activity patterns as represented by lower RA were consistently associated with higher BMI: comparing the bottom quintile (least robust) to the top quintile (most robust 24-hour rest-activity pattern) of RA, BMI was 3-kg/m2 higher (p = .02). Associations were similar in magnitude to an hour less of TST (1-kg/m2 higher BMI) or a 10% decrease in sleep efficiency (2-kg/m2 higher BMI), and independent of age, sex, race, education, and the duration of rest and/or activity. Lower RA, reflecting both higher night activity and lower daytime activity, was associated with higher BMI. Independent of the duration of rest or activity during the day or night, 24-hour rest, and activity patterns from actigraphy provide aggregated measures of activity that associate with BMI in community-dwelling adults. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  16. FIRST DETERMINATION OF THE TRUE MASS OF CORONAL MASS EJECTIONS: A NOVEL APPROACH TO USING THE TWO STEREO VIEWPOINTS

    International Nuclear Information System (INIS)

    Colaninno, Robin C.; Vourlidas, Angelos

    2009-01-01

    The twin Sun Earth Connection Coronal and Heliospheric Investigation (SECCHI) COR2 coronagraphs of the Solar Terrestrial Relations Observatory (STEREO) provide images of the solar corona from two viewpoints in the solar system. Since their launch in late 2006, the STEREO Ahead (A) and Behind (B) spacecraft have been slowly separating from Earth at a rate of 22. 0 5 per year. By the end of 2007, the two spacecraft were separated by more than 40 deg. from each other. At that time, we began to see large-scale differences in the morphology and total intensity between coronal mass ejections (CMEs) observed with SECCHI-COR2 on STEREO-A and B. Due to the effects of the Thomson scattering geometry, the intensity of an observed CME is dependent on the angle it makes with the observed plane of the sky. From the intensity images, we can calculate the integrated line-of-sight electron density and mass. We demonstrate that it is possible to simultaneously derive the direction and true total mass of the CME if we make the simple assumption that the same mass should be observed in COR2-A and B.

  17. [Determination of 21 fragrance allergens in toys by gas chromatography-ion trap mass spectrometry].

    Science.gov (United States)

    Lü, Qing; Zang, Qing; Bai, Hua; Li, Haiyu; Kang, Suyuan; Wang, Chao

    2012-05-01

    A method of gas chromatography-ion trap mass spectrometry (GC-IT-MS) was developed for the determination of 21 fragrance allergens in sticker toys, plush toys and plastic toys. The experimental conditions, such as sample pretreatment conditions, and the analytical conditions of GC-IT-MS, were optimized. The sticker toy samples and plush toy samples were extracted with acetone by ultrasonic wave, and the extracts were separated on an Agilent HP-1 MS column (50 m x 0.2 mm x 0.5 microm), then determined by IT-MS and quantified by external standard method. The plastic toy samples were extracted by the dissolution-precipitation approach, cleaned up with an Envi-carb solid phase extraction column and concentrated by rotary evaporation and nitrogen blowing, then determined by GC-IT-MS and quantified by external standard method. The calibration curves showed good linearity in the range of 0.002-50 mg/L with the correlation coefficients greater than 0.996 8. The limits of quantification (LOQ, S/N > 10) were 0.02-40 mg/kg. The average recoveries of the target compounds spiked in the sample at three concentration levels were in the range of 82.2%-110.8% with the relative standard deviations (RSDs) of 0.6%-10.5%. These results show that this method is accurate and sensitive for the qualitative and quantitative determination of the 21 fragrance allergens in the 3 types of toys.

  18. 232Th Mass Determination in a Uranium/Thorium Mixture for Safeguards Purposes

    International Nuclear Information System (INIS)

    Nangu, M.; Marumo, B.; Mbedzi, E.; Rasweswe, M.; Croft, S.; McElroy, R.; Chapman, J.; Bosko, A.

    2015-01-01

    In nuclear safeguards it is required that thorium content in safeguarded material should be quantified and reported as appropriate. As such the South African State System of Control and Accounting (SSAC) on discovering a number of safeguarded waste drums which contained considerable quantities of thorium decided to initiate a project to properly quantify their thorium content using a high purity germanium detector and In Situ Object Counting System (ISOCS) efficiency calibration software. These metal waste drums are contained inside overpacks which for health reasons cannot be opened and thus giving rise to the challenge of determining the exact fill heights and the density of the material. Fill heights determined using transmission sources and the material density calculated from them together with the geometry used for the overpacks could be used to further refine the ISOCS calibration geometry and thus improving the quantitative result. In order to have confidence on the ISOCS measurements, it was decided to also validate the ISOCS results through the preparation of similar density standards that would be used for the efficiency calibration in the determination of the 232Th activity in the material. In addition, MGAU v4.2, which was used to determine uranium enrichment in a measured material, also provides an approximate 232Th abundance relative to uranium content. ISOCS measurements of 232Th masses in waste drums were compared to MGAU results. Results of these studies are presented in this paper. (author)

  19. Dietary patterns in men and women are simultaneously determinants of altered glucose metabolism and bone metabolism.

    Science.gov (United States)

    Langsetmo, Lisa; Barr, Susan I; Dasgupta, Kaberi; Berger, Claudie; Kovacs, Christopher S; Josse, Robert G; Adachi, Jonathan D; Hanley, David A; Prior, Jerilynn C; Brown, Jacques P; Morin, Suzanne N; Davison, Kenneth S; Goltzman, David; Kreiger, Nancy

    2016-04-01

    We hypothesized that diet would have direct effects on glucose metabolism with direct and indirect effects on bone metabolism in a cohort of Canadian adults. We assessed dietary patterns (Prudent [fruit, vegetables, whole grains, fish, and legumes] and Western [soft drinks, potato chips, French fries, meats, and desserts]) from a semiquantitative food frequency questionnaire. We used fasting blood samples to measure glucose, insulin, homeostatic model assessment insulin resistance (HOMA-IR), 25-hydroxyvitamin D (25OHD), parathyroid hormone, bone-specific alkaline phosphatase (a bone formation marker), and serum C-terminal telopeptide (CTX; a bone resorption marker). We used multivariate regression models adjusted for confounders and including/excluding body mass index. In a secondary analysis, we examined relationships through structural equations models. The Prudent diet was associated with favorable effects on glucose metabolism (lower insulin and HOMA-IR) and bone metabolism (lower CTX in women; higher 25OHD and lower parathyroid hormone in men). The Western diet was associated with deleterious effects on glucose metabolism (higher glucose, insulin, and HOMA-IR) and bone metabolism (higher bone-specific alkaline phosphatase and lower 25OHD in women; higher CTX in men). Body mass index adjustment moved point estimates toward the null, indicating partial mediation. The structural equation model confirmed the hypothesized linkage with strong effects of Prudent and Western diet on metabolic risk, and both direct and indirect effects of a Prudent diet on bone turnover. In summary, a Prudent diet was associated with lower metabolic risk with both primary and mediated effects on bone turnover, suggesting that it is a potential target for reducing fracture risk. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Structural and interpersonal characteristics of family meals: associations with adolescent body mass index and dietary patterns.

    Science.gov (United States)

    Berge, Jerica M; Jin, Seok Won; Hannan, Peter; Neumark-Sztainer, Dianne

    2013-06-01

    The last decade of research has suggested that family meals play an important role in promoting healthful dietary intake in youth. However, little is known about the structural characteristics and interpersonal dynamics of family meals that might help to inform why family meals are protective for youth. The current mixed methods, cross-sectional study conducted in 2010-2011 includes adolescents and parents who participated in two linked population-based studies. Participants included 40 parents (91.5% female) and adolescents (57.5% female) from the Minneapolis/St Paul, MN, area participating in EAT (Eating and Activity Among Teens) 2010 and F-EAT (Families and Eating and Activity Among Teens). The structural (eg, length of the meal, types of foods served) and interpersonal characteristics (eg, communication, emotion/affect management) of family meals were described, and associations between interpersonal dynamics at family meals and adolescent body mass index and dietary intake were examined via direct observational methods. Families were videorecorded during two mealtimes in their homes. Results indicated that family meals were approximately 20 minutes in length, included multiple family members, were typically served family style (70%), and occurred in the kitchen 62% of the time and 38% of the time in another room (eg, family room, office). In addition, significant associations were found between positive interpersonal dynamics (ie, communication, affect management, interpersonal involvement, overall family functioning) at family meals and lower adolescent body mass index and higher vegetable intake. These findings add to the growing body of literature on family meals by providing a better understanding of what is happening at family meals in order to inform obesity-prevention studies and recommendations for providers working with families of youth. Copyright © 2013 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  1. Association between magnetic resonance imaging patterns and baseline disease features in multiple myeloma: analyzing surrogates of tumour mass and biology

    Energy Technology Data Exchange (ETDEWEB)

    Mai, Elias K.; Merz, Maximilian; Shah, Sofia; Hillengass, Michaela; Wagner, Barbara; Hose, Dirk; Raab, M.S. [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); Hielscher, Thomas [German Cancer Research Center, Division of Biostatistics, Heidelberg (Germany); Kloth, Jost K.; Weber, Marc-Andre [University Hospital of Heidelberg, Clinic of Diagnostic and Interventional Radiology, Heidelberg (Germany); Jauch, Anna [University Hospital of Heidelberg, Institute of Human Genetics, Heidelberg (Germany); Delorme, Stefan [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Goldschmidt, Hartmut [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); National Center for Tumor Diseases (NCT) Heidelberg, Heidelberg (Germany); Hillengass, Jens [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); German Cancer Research Center, Department of Radiology, Heidelberg (Germany)

    2016-11-15

    To assess associations between bone marrow infiltration patterns and localization in magnetic resonance imaging (MRI) and baseline clinical/prognostic parameters in multiple myeloma (MM). We compared baseline MM parameters, MRI patterns and localization of focal lesions to the mineralized bone in 206 newly diagnosed MM patients. A high tumour mass (represented by International Staging System stage III) was significantly associated with severe diffuse infiltration (p = 0.015) and a higher number of focal lesions (p = 0.006). Elevated creatinine (p = 0.003), anaemia (p < 0.001) and high LDH (p = 0.001) correlated with severe diffuse infiltration. A salt and pepper diffuse pattern had a favourable prognosis. A higher degree of destruction of mineralized bone (assessed by X-ray or computed tomography) was associated with an increasing number of focal lesions on MRI (p < 0.001). Adverse cytogenetics (del17p/gain1q21/t(4;14)) were associated with diffuse infiltration (p = 0.008). The presence of intraosseous focal lesions exceeding the mineralized bone had a borderline significant impact on prognosis. Diffuse bone marrow infiltration on MRI correlates with adverse cytogenetics, lowered haemoglobin values and high tumour burden in newly diagnosed MM whereas an increasing number of focal lesions correlates with a higher degree of bone destruction. Focal lesions exceeding the cortical bone did not adversely affect the prognosis. (orig.)

  2. Quantitative determination of carbonaceous particle mixing state in Paris using single particle mass spectrometer and aerosol mass spectrometer measurements

    Science.gov (United States)

    Healy, R. M.; Sciare, J.; Poulain, L.; Crippa, M.; Wiedensohler, A.; Prévôt, A. S. H.; Baltensperger, U.; Sarda-Estève, R.; McGuire, M. L.; Jeong, C.-H.; McGillicuddy, E.; O'Connor, I. P.; Sodeau, J. R.; Evans, G. J.; Wenger, J. C.

    2013-04-01

    Single particle mixing state information can be a powerful tool for assessing the relative impact of local and regional sources of ambient particulate matter in urban environments. However, quantitative mixing state data are challenging to obtain using single particle mass spectrometers. In this study, the quantitative chemical composition of carbonaceous single particles has been estimated using an aerosol time-of-flight mass spectrometer (ATOFMS) as part of the MEGAPOLI 2010 winter campaign in Paris, France. Relative peak areas of marker ions for elemental carbon (EC), organic aerosol (OA), ammonium, nitrate, sulphate and potassium were compared with concurrent measurements from an Aerodyne high resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS), a thermal/optical OCEC analyser and a particle into liquid sampler coupled with ion chromatography (PILS-IC). ATOFMS-derived mass concentrations reproduced the variability of these species well (R2 = 0.67-0.78), and ten discrete mixing states for carbonaceous particles were identified and quantified. Potassium content was used to identify particles associated with biomass combustion. The chemical mixing state of HR-ToF-AMS organic aerosol factors, resolved using positive matrix factorization, was also investigated through comparison with the ATOFMS dataset. The results indicate that hydrocarbon-like OA (HOA) detected in Paris is associated with two EC-rich mixing states which differ in their relative sulphate content, while fresh biomass burning OA (BBOA) is associated with two mixing states which differ significantly in their OA/EC ratios. Aged biomass burning OA (OOA2-BBOA) was found to be significantly internally mixed with nitrate, while secondary, oxidized OA (OOA) was associated with five particle mixing states, each exhibiting different relative secondary inorganic ion content. Externally mixed secondary organic aerosol was not observed. These findings demonstrate the heterogeneity of primary and

  3. OPERATIONS THROUGHPUT AS A DETERMINANT OF GOLDEN-HOUR IN MASS-GATHERING MEDICINE

    Directory of Open Access Journals (Sweden)

    I. D. Khan

    2017-07-01

    Full Text Available BACKGROUND Golden-hour, a time-tested concept for trauma-care, involves a systems approach encompassing healthcare, logistics, geographical, environmental and temporal variables. Golden-hour paradigm in mass-gathering-medicine such as the Hajj-pilgrimage entwines along healthcare availability, accessibility, efficiency and interoperability; expanding from the patient-centric to public-health centric approach. The realm of mass-gathering-medicine invokes an opportunity for incorporating operations-throughput as a determinant of golden-hour for overall capacity-building and interoperability. METHODS Golden-hour was evaluated during the Indian-Medical-Mission operations for Hajj-2016; which established, operated and coordinated a strategic network of round-the-clock medical operations. Throughput was evaluated as deliverables/time, against established Standard-Operating-Procedures for various clinical, investigation, drug-dispensing and patient-transfer algorithms. Patient encounter-time, waiting-time, turnaround-time were assessed throughout echeloned healthcare under a patient-centric healthcare-delivery model. Dynamic evaluation was carried out to cater for variation and heterogeneity. RESULTS Massive surge of 3,94,013 patients comprising 2,25,103 males (57.1% and 1,68,910 females (42.9% overwhelmed the throughput capacities of outpatient attendance, pharmacy, laboratory, imaging, ambulance, referrals and documentation. There was delay in attendance, suspicion, diagnosis and isolation of patients with communicable infections. The situational-analysis of operations-throughput highlights wasted turnaround-time due to mobilization of medical-team, diverting critical healthcare resources away from emergency situations. CONCLUSION Time being a crucial factor in the complexity of medical-care, operations-throughput remains an important determinant towards interoperability of bottlenecks, thereby being a determinant of golden-hour in mass

  4. Phase shifts and nonellipsoidal light curves: Challenges from mass determinations in x-ray binary stars

    Science.gov (United States)

    Cantrell, Andrew Glenn

    We consider two types of anomalous observations which have arisen from efforts to measure dynamical masses of X-ray binary stars: (1) Radial velocity curves which seemingly show the primary and the secondary out of antiphase in most systems, and (2) The observation of double-waved light curves which deviate significantly from the ellipsoidal modulations expected for a Roche lobe filling star. We consider both problems with the joint goals of understanding the physical origins of the anomalous observations, and using this understanding to allow robust dynamical determinations of mass in X-ray binary systems. In our analysis of phase-shifted radial velocity curves, we discuss a comprehensive sample of X-ray binaries with published phase-shifted radial velocity curves. We show that the most commonly adopted explanation for phase shifts is contradicted by many observations, and consider instead a generalized form of a model proposed by Smak in 1970. We show that this model is well supported by a range of observations, including some systems which had previously been considered anomalous. We lay the groundwork for the derivation of mass ratios based on our explanation for phase shifts, and we discuss the work necessary to produce more detailed physical models of the phase shift. In our analysis of non-ellipsoidal light curves, we focus on the very well-studied system A0620-00. We present new VIH SMARTS photometry spanning 1999-2007, and supplement this with a comprehensive collection of archival data obtained since 1981. We show that A0620-00 undergoes optical state changes within X-ray quiescence and argue that not all quiescent data should be used for determinations of the inclination. We identify twelve light curves which may reliably be used for determining the inclination. We show that the accretion disk contributes significantly to all twelve curves and is the dominant source of nonellipsoidal variations. We derive the disk fraction for each of the twelve curves

  5. Socio-demographic and the lifestyle determinants of 'Western-like' and 'Health conscious' dietary patterns in toddlers

    NARCIS (Netherlands)

    Kiefte-de Jong, J.C.; Vries, de J.H.M.; Bleeker, S.E.; Jaddoe, V.W.; Hofman, M.K.; Raat, H.; Moll, H.

    2013-01-01

    Determinants of a child's diet shortly after weaning and lactation have been relatively understudied. The aim of the present study was hence to identify common dietary patterns in toddlers and to explore parental and child indicators of these dietary patterns. The study was a population-based,

  6. Determination of phospholipid regiochemistry by Ag(I) adduction and tandem mass spectrometry.

    Science.gov (United States)

    Yoo, Hyun Ju; Håkansson, Kristina

    2011-02-15

    Collision-activated dissociation (CAD) and infrared multiphoton dissociation (IRMPD) of Ag-adducted phospholipids were investigated as structural tools. Previously, determination of the acyl chains at the two phospholipid esterification sites has been performed based on the R(1)COO(-)/R(2)COO(-) ratio in negative ion mode CAD tandem mass spectrometry. However, the observed product ion ratio is dependent on the extent of unsaturation of the fatty acyl group at sn-2 as well as on the total chain length. Similarly, in positive ion mode CAD with/without alkaline or alkaline earth metal adduction, the ratio of product ions resulting from either R(1)COOH or R(2)COOH neutral losses is dependent on the nature of the phospholipid polar headgroup. Ag(+) ion chromatography, in which silver ions are part of the stationary phase, can provide information on double bond number/distribution as well as double bond configuration (cis/trans) because of interaction between Ag(+) ions and olefinic π electrons of fatty acids and lipids. We hypothesized that interactions between double bonds and Ag(+) may be utilized to also reveal phospholipid esterification site information in tandem mass spectrometry. CAD and IRMPD of Ag-adducted phospholipids with unsaturated fatty acids (R(x)COOH, x = 1 or 2) provided characteristic product ions, [R(x)COOH + Ag](+), and their neutral losses. The characteristic product ions and their abundances do not depend on the type of polar headgroup or the number of double bonds of unsaturated acyl chains. Tandem mass spectrometry of Cu-adducted phospholipids was also performed for comparison based on the Lewis acid and base properties of Cu(+) and phospholipid double bonds, respectively.

  7. Phyllotactic pattern and stem cell fate are determined by the Arabidopsis homeobox gene BELLRINGER

    Science.gov (United States)

    Mary E. Byrne; Andrew T. Groover; Joseph R. Fontana; Robert A. Martienssen

    2003-01-01

    Lateral organs in plants arise from the meristem in a stereotypical pattern known as phyllotaxy. Spiral patterns result from initiation of successive organs at a fixed angle of divergence but variable patterns of physical contact. Such patterns ultimately give rise to individual leaves and flowers at positions related to each other by consecutive terms in the...

  8. Determination of ruthenium in photographic emulsions - Development and comparison of different sample treatments and mass spectrometric methods

    NARCIS (Netherlands)

    Krystek, Petra; Heumann, Klaus G.

    1999-01-01

    Different sample treatment procedures were combined with inductively coupled plasma mass spectrometry (ICP-MS) and negative thermal ionisation mass spectrometry (NTI-MS) for the determination of ruthenium traces in photographic emulsions. Dissolution of the samples in concentrated ammonia solution

  9. Downsizing of lean body mass is a key determinant of Alzheimer's disease.

    Science.gov (United States)

    Ingenbleek, Yves; Bernstein, Larry H

    2015-01-01

    Lean body mass (LBM) encompasses all metabolically active organs distributed into visceral and structural tissue compartments and collecting the bulk of N and K stores of the human body. Transthyretin (TTR) is a plasma protein mainly secreted by the liver within a trimolecular TTR-RBP-retinol complex revealing from birth to old age strikingly similar evolutionary patterns with LBM in health and disease. TTR is also synthesized by the choroid plexus along distinct regulatory pathways. Chronic dietary methionine (Met) deprivation or cytokine-induced inflammatory disorders generates LBM downsizing following differentiated physiopathological processes. Met-restricted regimens downregulate the transsulfuration cascade causing upstream elevation of homocysteine (Hcy) safeguarding Met homeostasis and downstream drop of hydrogen sulfide (H2S) impairing anti-oxidative capacities. Elderly persons constitute a vulnerable population group exposed to increasing Hcy burden and declining H2S protection, notably in plant-eating communities or in the course of inflammatory illnesses. Appropriate correction of defective protein status and eradication of inflammatory processes may restore an appropriate LBM size allowing the hepatic production of the retinol circulating complex to resume, in contrast with the refractory choroidal TTR secretory process. As a result of improved health status, augmented concentrations of plasma-derived TTR and retinol may reach the cerebrospinal fluid and dismantle senile amyloid plaques, contributing to the prevention or the delay of the onset of neurodegenerative events in elderly subjects at risk of Alzheimer's disease.

  10. Connectivity to the surface determines diversity patterns in subsurface aquifers of the Fennoscandian shield.

    Science.gov (United States)

    Hubalek, Valerie; Wu, Xiaofen; Eiler, Alexander; Buck, Moritz; Heim, Christine; Dopson, Mark; Bertilsson, Stefan; Ionescu, Danny

    2016-10-01

    Little research has been conducted on microbial diversity deep under the Earth's surface. In this study, the microbial communities of three deep terrestrial subsurface aquifers were investigated. Temporal community data over 6 years revealed that the phylogenetic structure and community dynamics were highly dependent on the degree of isolation from the earth surface biomes. The microbial community at the shallow site was the most dynamic and was dominated by the sulfur-oxidizing genera Sulfurovum or Sulfurimonas at all-time points. The microbial community in the meteoric water filled intermediate aquifer (water turnover approximately every 5 years) was less variable and was dominated by candidate phylum OD1. Metagenomic analysis of this water demonstrated the occurrence of key genes for nitrogen and carbon fixation, sulfate reduction, sulfide oxidation and fermentation. The deepest water mass (5000 year old waters) had the lowest taxon richness and surprisingly contained Cyanobacteria. The high relative abundance of phylogenetic groups associated with nitrogen and sulfur cycling, as well as fermentation implied that these processes were important in these systems. We conclude that the microbial community patterns appear to be shaped by the availability of energy and nutrient sources via connectivity to the surface or from deep geological processes.

  11. Selective modes determine evolutionary rates, gene compactness and expression patterns in Brassica.

    Science.gov (United States)

    Guo, Yue; Liu, Jing; Zhang, Jiefu; Liu, Shengyi; Du, Jianchang

    2017-07-01

    It has been well documented that most nuclear protein-coding genes in organisms can be classified into two categories: positively selected genes (PSGs) and negatively selected genes (NSGs). The characteristics and evolutionary fates of different types of genes, however, have been poorly understood. In this study, the rates of nonsynonymous substitution (K a ) and the rates of synonymous substitution (K s ) were investigated by comparing the orthologs between the two sequenced Brassica species, Brassica rapa and Brassica oleracea, and the evolutionary rates, gene structures, expression patterns, and codon bias were compared between PSGs and NSGs. The resulting data show that PSGs have higher protein evolutionary rates, lower synonymous substitution rates, shorter gene length, fewer exons, higher functional specificity, lower expression level, higher tissue-specific expression and stronger codon bias than NSGs. Although the quantities and values are different, the relative features of PSGs and NSGs have been largely verified in the model species Arabidopsis. These data suggest that PSGs and NSGs differ not only under selective pressure (K a /K s ), but also in their evolutionary, structural and functional properties, indicating that selective modes may serve as a determinant factor for measuring evolutionary rates, gene compactness and expression patterns in Brassica. © 2017 The Authors The Plant Journal © 2017 John Wiley & Sons Ltd.

  12. How temporal patterns in rainfall determine the geomorphology and carbon fluxes of tropical peatlands

    Science.gov (United States)

    Hoyt, Alison M.; Gandois, Laure; Eri, Jangarun; Dommain, René; Abu Salim, Kamariah; Kai, Fuu Ming; Haji Su’ut, Nur Salihah; Harvey, Charles F.

    2017-01-01

    Tropical peatlands now emit hundreds of megatons of carbon dioxide per year because of human disruption of the feedbacks that link peat accumulation and groundwater hydrology. However, no quantitative theory has existed for how patterns of carbon storage and release accompanying growth and subsidence of tropical peatlands are affected by climate and disturbance. Using comprehensive data from a pristine peatland in Brunei Darussalam, we show how rainfall and groundwater flow determine a shape parameter (the Laplacian of the peat surface elevation) that specifies, under a given rainfall regime, the ultimate, stable morphology, and hence carbon storage, of a tropical peatland within a network of rivers or canals. We find that peatlands reach their ultimate shape first at the edges of peat domes where they are bounded by rivers, so that the rate of carbon uptake accompanying their growth is proportional to the area of the still-growing dome interior. We use this model to study how tropical peatland carbon storage and fluxes are controlled by changes in climate, sea level, and drainage networks. We find that fluctuations in net precipitation on timescales from hours to years can reduce long-term peat accumulation. Our mathematical and numerical models can be used to predict long-term effects of changes in temporal rainfall patterns and drainage networks on tropical peatland geomorphology and carbon storage. PMID:28607068

  13. How temporal patterns in rainfall determine the geomorphology and carbon fluxes of tropical peatlands.

    Science.gov (United States)

    Cobb, Alexander R; Hoyt, Alison M; Gandois, Laure; Eri, Jangarun; Dommain, René; Abu Salim, Kamariah; Kai, Fuu Ming; Haji Su'ut, Nur Salihah; Harvey, Charles F

    2017-06-27

    Tropical peatlands now emit hundreds of megatons of carbon dioxide per year because of human disruption of the feedbacks that link peat accumulation and groundwater hydrology. However, no quantitative theory has existed for how patterns of carbon storage and release accompanying growth and subsidence of tropical peatlands are affected by climate and disturbance. Using comprehensive data from a pristine peatland in Brunei Darussalam, we show how rainfall and groundwater flow determine a shape parameter (the Laplacian of the peat surface elevation) that specifies, under a given rainfall regime, the ultimate, stable morphology, and hence carbon storage, of a tropical peatland within a network of rivers or canals. We find that peatlands reach their ultimate shape first at the edges of peat domes where they are bounded by rivers, so that the rate of carbon uptake accompanying their growth is proportional to the area of the still-growing dome interior. We use this model to study how tropical peatland carbon storage and fluxes are controlled by changes in climate, sea level, and drainage networks. We find that fluctuations in net precipitation on timescales from hours to years can reduce long-term peat accumulation. Our mathematical and numerical models can be used to predict long-term effects of changes in temporal rainfall patterns and drainage networks on tropical peatland geomorphology and carbon storage.

  14. The Analysis Performance Method Naive Bayes Andssvm Determine Pattern Groups of Disease

    Science.gov (United States)

    Sitanggang, Rianto; Tulus; Situmorang, Zakarias

    2017-12-01

    Information is a very important element and into the daily needs of the moment, to get a precise and accurate information is not easy, this research can help decision makers and make a comparison. Researchers perform data mining techniques to analyze the performance of methods and algorithms naïve Bayes methods Smooth Support Vector Machine (ssvm) in the grouping of the disease.The pattern of disease that is often suffered by people in the group can be in the detection area of the collection of information contained in the medical record. Medical records have infromasi disease by patients in coded according to standard WHO. Processing of medical record data to find patterns of this group of diseases that often occur in this community take the attribute address, sex, type of disease, and age. Determining the next analysis is grouping of four ersebut attribute. From the results of research conducted on the dataset fever diabete mellitus, naïve Bayes method produces an average value of 99% and an accuracy and SSVM method produces an average value of 93% accuracy

  15. Determination of thiopurine S-methyltransferase activity by hydrophilic interaction liquid chromatography hyphenated with mass spectrometry.

    Science.gov (United States)

    Pecher, Daniel; Dokupilová, Svetlana; Zelinková, Zuzana; Peppelenbosch, Maikel; Mikušová, Veronika; Mikuš, Peter

    2017-08-05

    Thiopurine S-methyltransferase (TPMT) plays an important role in the metabolism of thiopurines used in the therapy of inflammatory bowel diseases (IBD). In this work a new progressive method for the determination of TPMT activity in red blood cells lysates was developed. Analysis was carried out by means of hydrophilic interaction liquid chromatography (HILIC) hyphenated with mass spectrometry (MS). In comparison with reversed-phase high-performance liquid chromatography (RP-HPLC), that has been typically applied in determination of TPMT activity, the HILIC significantly improved the analytical signal provided by MS, shortened analysis time, and improved chromatographic resolution. The HILIC-HPLC-MS method was optimized and validated, providing favorable parameters of detection and quantitation limits (5.5 and 16.5pmol/mL, respectively), linearity (coefficient of determination 0.9999 in the range of 0.01-1.0nmol/mL), recovery and precision (93.25-100.37% with RSD 1.06-1.32% in the whole concentration range of QC samples). Moreover, in contrast to the conventional RP-HPLC-UV approach, the complex phenotype TPMT profiles can be reliably and without interferences monitored using the HILIC-HPLC-MS method. Such advanced monitoring can provide valuable detail information on the thiopurines (e.g. evaluating ratio of methylated and non-methylated 6-mercaptopurine) and, by that, TPMT action in biological systems before and during the therapy of IBD. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Determination of pyrrolizidine alkaloids in selected feed materials with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kowalczyk, Ewelina; Kwiatek, Krzysztof

    2017-05-01

    1,2-Dehydropyrrolizidine alkaloids are known to be toxic to many animals and humans. To provide safety of feeds a method based on gas chromatography-mass spectrometry enabling the determination of a content of 1,2-unsaturated PAs in feed materials was developed. After extraction with aqueous solution of HCl and purification of the extract, 1,2-unsaturated alkaloids are reduced to their common backbone structures and subsequently derivatised with heptafluorobutyric anhydride (HFBA). The method was validated according to SANTE/11945/2015. All received parameters are consistent with the document requirements as recovery of a final compound retronecine derivative was from 81.8% to 94.4% when retrosine was used for spiking and from 72.7% to 85.5% when retrorsine N-oxide was spiked. The repeatability was calculated as relative standards deviation and ranged from 7.5% to 14.4%, for N-oxide was from 7.9% to 15.4%. The reproducibility was in the range from 14.2% to 16.3% and from 17.0% to 18.1% for free base and N-oxide respectively. The limit of quantification was determined as 10 µg kg - 1 . Good linearity of the method was obtained with coefficient of determination R 2  > 0.99. The method was applied to 35 silage and two hay samples analysis.

  17. Determining Membrane Protein-Lipid Binding Thermodynamics Using Native Mass Spectrometry.

    Science.gov (United States)

    Cong, Xiao; Liu, Yang; Liu, Wen; Liang, Xiaowen; Russell, David H; Laganowsky, Arthur

    2016-04-06

    Membrane proteins are embedded in the biological membrane where the chemically diverse lipid environment can modulate their structure and function. However, the thermodynamics governing the molecular recognition and interaction of lipids with membrane proteins is poorly understood. Here, we report a method using native mass spectrometry (MS), to determine thermodynamics of individual ligand binding events to proteins. Unlike conventional methods, native MS can resolve individual ligand binding events and, coupled with an apparatus to control the temperature, determine binding thermodynamic parameters, such as for protein-lipid interactions. We validated our approach using three soluble protein-ligand systems (maltose binding protein, lysozyme, and nitrogen regulatory protein) and obtained similar results to those using isothermal titration calorimetry and surface plasmon resonance. We also determined for the first time the thermodynamics of individual lipid binding to the ammonia channel (AmtB), an integral membrane protein from Escherichia coli. Remarkably, we observed distinct thermodynamic signatures for the binding of different lipids and entropy-enthalpy compensation for binding lipids of variable chain length. Additionally, using a mutant form of AmtB that abolishes a specific phosphatidylglycerol (PG) binding site, we observed distinct changes in the thermodynamic signatures for binding PG, implying these signatures can identify key residues involved in specific lipid binding and potentially differentiate between specific lipid binding sites.

  18. Determination of 238U in marine organisms by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Ishii, Toshiaki; Nakahara, Motokazu; Matsuba, Mitsue; Ishikawa, Masafumi

    1991-01-01

    Determination of 238 U in fifty-five species of marine organisms was carried out by inductively coupled plasma mass spectrometry which showed some advantages such as high sensitivity, wide dynamic range and small interferences from matrices for the analysis of high mass elements. The concentrations of 238 U in soft tissues of marine animals ranged from 0.076 to 5000 ng/g wet wt. Especially, the branchial heart of cephalopod molluscs showed the specific accumulation of 238 U. The concentration factor of the branchial heart of Octopus vulgaris, which indicated the highest value, was calculated to be about 10 3 by comparing it with the concentration of 238 U (3.2±0.2 ng/ml) in coastal seawaters of Japan. The concentrations of 238 U in hard tissues of marine invertebrates were similar to those in soft tissues. In contrast, hard tissues like bone, scale, fin, etc. of fishes showed much higher concentrations of 238 U than soft tissues like muscle and liver. The concentrations of 238 U of twenty species of algae ranged from 10 to 3700 ng/g dry wt. (author)

  19. Gas chromatographic/mass spectrometric determination of carbon isotope composition in unpurified samples: methamphetamine example.

    Science.gov (United States)

    Low, I A; Liu, R H; Legendre, M G; Piotrowski, E G; Furner, R L

    1986-10-01

    A gas chromatograph/quadrupole mass spectrometer system, operated in electron impact/selected ion monitoring mode, is used to determine the intensity ratio of the m/z 59 and the m/z 58 ions of the [C3H8N]+ fragment derived from methamphetamine samples synthesized with varying amounts of 13C-labeled methylamine. Crude products are introduced into the gas chromatograph without prior cleanup. The ratios measured were in excellent agreement with those calculated. A change in 0.25% use of 13C-methylamine is sufficient for product differentiation. The feasibility of using isotope labeling and subsequent mass spectrometric isotope ratio measurement as the basis of a compound tracing mechanism is discussed. Specifically, if methamphetamine samples manufactured from legal sources are asked to incorporate distinct 13C compositions, their sources can be traced when samples are diverted into illegal channels. Samples derived from illicit preparations can also be traced if the manufacturers of a precursor (methylamine in this case) incorporate distinct 13C compositions in their products.

  20. Determination of elemental composition of metals using ambient organic mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shiea, Christopher [Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, 100 Shih-Chuan 1st Rd, Kaohsiung 807, Taiwan (China); Huang, Yeou-Lih [Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, 100 Shih-Chuan 1st Rd, Kaohsiung 807, Taiwan (China); Department of Chemistry, National Sun Yat-Sen University, 70 Lien-Hai Rd, Kaohsiung 804, Taiwan (China); Cheng, Sy-Chyi; Chen, Yi-Lun [Department of Chemistry, National Sun Yat-Sen University, 70 Lien-Hai Rd, Kaohsiung 804, Taiwan (China); Shiea, Jentaie, E-mail: jetea@mail.nsysu.edu.tw [Department of Chemistry, National Sun Yat-Sen University, 70 Lien-Hai Rd, Kaohsiung 804, Taiwan (China); Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, 100 Shih-Chuan 1st Rd, Kaohsiung 807, Taiwan (China)

    2017-05-22

    Conventional inorganic mass spectrometric (MS) analysis of metals can require time-consuming and tedious sample preparation. We thus report the novel and direct characterization of metals in solid samples using an organic MS technique known as electrospray laser desorption ionization mass spectrometry (ELDI/MS). No sample pretreatment was needed, and results were rapidly obtained due to the ambient and laser-based nature of ELDI/MS. Metals from samples were desorbed and ionized by laser irradiation, after which they reacted with EDTA and then post-ionized and detected as metal-EDTA complexes. Aluminum, copper, iron, lead, nickel, and zinc from plates, foils, and coins were characterized in seconds. This study demonstrates that an ESI/MS system can be easily modified to analyze metal elements in solids by involving a chelating agent, indicating a potentially promising development in MS towards the analysis of metals using organic MS. - Highlights: • “Organic MS” was utilized as “inorganic MS” to detect metal ions in solid samples. • Element ions desorbed by laser irradiation rapidly reacted with a chelating reagent before they were detected by MS. • Elemental composition of metals was determined by this “Organic MS” method.

  1. Enantiomeric determination of DOPA in dietary supplements containing Mucuna pruriens by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Hasegawa, Takashi; Takahashi, Kazunaga; Fukiwake, Tomohide; Saijo, Masaaki; Motoki, Yuji

    2013-01-01

    We developed a simple and rapid liquid chromatography/mass spectrometry (LC/MS) method for the enantiomeric determination of DOPA in dietary supplements containing Mucuna pruriens. L- and D-DOPA were ultrasonically extracted with 1% formic acid aqueous solution. The isolated extracts were analyzed by LC/MS using a Crownpak CR (-) column at 30℃. The mass spectrometer was operated in the positive mode of electrospray ionization, and the mobile phase was aqueous formic acid (pH 2.0). L-DOPA-ring-d3 was used as an internal standard. The method was validated for a dietary supplement spiked with L- and D-DOPA at 50 and 500 μg/g, respectively, and the recoveries of the DOPA enantiomers were between 97.5% and 101.3%. Relative standard deviation values of repeatability and intermediate precision were less than 7%. The method was applied to 14 dietary supplements. L-DOPA was detected in these supplements in the range of 0.88-12.8 mg/unit. D-DOPA was not detected.

  2. Determination of elemental composition of metals using ambient organic mass spectrometry

    International Nuclear Information System (INIS)

    Shiea, Christopher; Huang, Yeou-Lih; Cheng, Sy-Chyi; Chen, Yi-Lun; Shiea, Jentaie

    2017-01-01

    Conventional inorganic mass spectrometric (MS) analysis of metals can require time-consuming and tedious sample preparation. We thus report the novel and direct characterization of metals in solid samples using an organic MS technique known as electrospray laser desorption ionization mass spectrometry (ELDI/MS). No sample pretreatment was needed, and results were rapidly obtained due to the ambient and laser-based nature of ELDI/MS. Metals from samples were desorbed and ionized by laser irradiation, after which they reacted with EDTA and then post-ionized and detected as metal-EDTA complexes. Aluminum, copper, iron, lead, nickel, and zinc from plates, foils, and coins were characterized in seconds. This study demonstrates that an ESI/MS system can be easily modified to analyze metal elements in solids by involving a chelating agent, indicating a potentially promising development in MS towards the analysis of metals using organic MS. - Highlights: • “Organic MS” was utilized as “inorganic MS” to detect metal ions in solid samples. • Element ions desorbed by laser irradiation rapidly reacted with a chelating reagent before they were detected by MS. • Elemental composition of metals was determined by this “Organic MS” method.

  3. Determination of test methods for the prediction of the behavior of mass concrete

    Science.gov (United States)

    Ferraro, Christopher C.

    Hydration at early ages results from chemical and physical processes that take place between Portland cement and water, and is an exothermic process. The resultant heat evolution and temperature rise for massive concrete placements can be so great that the temperature differentials between the internal concrete core and outer concrete stratum can cause cracking due to thermal gradients. Accurate prediction of temperature distribution and stresses in mass concrete is needed to determine if a given concrete mixture design may have problems in the field, so that adjustments to the design can be made prior to its use. This research examines calorimetric, strength, and physical testing methods in an effort to predict the thermal and physical behavior of mass concrete. Four groups of concrete mixture types containing different cementitious materials are examined. One group contains Portland cement, while the other three groups incorporate large replacements of supplementary cementitious materials: granulated blast furnace slag, fly ash, and a ternary blend (combining Portland cement, fly ash, and slag).

  4. Semiempirical method of determining flow coefficients for pitot rake mass flow rate measurements

    Science.gov (United States)

    Trefny, C. J.

    1985-01-01

    Flow coefficients applicable to area-weighted pitot rake mass flow rate measurements are presented for fully developed, turbulent flow in an annulus. A turbulent velocity profile is generated semiempirically for a given annulus hub-to-tip radius ratio and integrated numerically to determine the ideal mass flow rate. The calculated velocities at each probe location are then summed, and the flow rate as indicated by the rake is obtained. The flow coefficient to be used with the particular rake geometry is subsequently obtained by dividing the ideal flow rate by the rake-indicated flow rate. Flow coefficients ranged from 0.903 for one probe placed at a radius dividing two equal areas to 0.984 for a 10-probe area-weighted rake. Flow coefficients were not a strong function of annulus hub-to-tip radius ratio for rakes with three or more probes. The semiempirical method used to generate the turbulent velocity profiles is described in detail.

  5. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Determination and pharmacokinetic studies of arecoline in dog plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Li, Bing; Zhou, Xu-Zheng; Li, Jian-Yong; Yang, Ya-Jun; Niu, Jian-Rong; Wei, Xiao-Juan; Liu, Xi-Wang; Li, Jin-Shan; Zhang, Ji-Yu

    2014-10-15

    A rapid and sensitive high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of arecoline concentration in dog plasma. Plasma sample was prepared by protein precipitation using n-hexane (containing 1% isoamyl alcohol) with β-pinene as an internal standard. Chromatographic separation was achieved on an Agilent C18 column (4.6×75mm, 3.5μm) using methanol: 5mM ammonium acetate as the mobile phase with isocratic elution. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve for arecoline was linear over a concentration range of 2-500ng/mL. The intra-day and inter-day accuracy and precision were within the acceptable limits of ±10% at all concentrations. In summary, the LC-MS/MS method described herein was fully validated and successfully applied to the pharmacokinetic study of arecoline hydrobromide tablets in dogs after oral administration. Copyright © 2014. Published by Elsevier B.V.

  7. Rapid determination of uranium in natural waters by fthermal emission mass spectrometry

    International Nuclear Information System (INIS)

    Ferguson, J.R.; Caylor, J.D.; Rogers, E.R.; Cole, S.H.

    1977-03-01

    A method has been developed to rapidly analyze natural water samples for part-per-trillion (ng/l) concentrations of uranium using a custom-built thermal-emission mass spectrometer. The filtered water sample is spiked with 233 U as an internal standard and extracted with a 2 percent solution of TOPO (trioctylphosphine oxide) in carbon tetrachloride. An aliquot of the organic phase is evaporated and the uranium in the residue extracted with aqueous ammonium carbonate. A 5j-μl aliquot is taken and dried on a flat uranium concentration of 3 ng/l will yield a count rate greater than three times the standard deviation, plus the mean of the background, and is defined as the lowest determinable concentration. The standard deviation of the method is 3 percent at accuracy of the method has been evaluated by comparing the results with a fluorescence procedure. There is very good agreement for water samples with uranium concentrations from 200 to 1000 ng/l. The mass spectrometer is a 6-in. -radius, 60-degree-sector instrument equipped for ion counting and having a vacuum system allowing rapid sample changing while maintaining a high source vacuum. A multiplexer and high-voltage s witch provide synchronized peak switching and scaler gating for monitoring three isotopes of uranium 238, 235, and 233. With this instrument, an analyst can achieve an analysis rate in excess of 50 samples per eight-hour shift

  8. Using a mass balance to determine the potency loss during the production of a pharmaceutical blend.

    Science.gov (United States)

    Mackaplow, Michael B

    2010-09-01

    The manufacture of a blend containing the active pharmaceutical ingredient (API) and inert excipients is a precursor for the production of most pharmaceutical capsules and tablets. However, if there is a net water gain or preferential loss of API during production, the potency of the final drug product may be less than the target value. We use a mass balance to predict the mean potency loss during the production of a blend via wet granulation and fluidized bed drying. The result is an explicit analytical equation for the change in blend potency a function of net water gain, solids losses (both regular and high-potency), and the fraction of excipients added extragranularly. This model predicts that each 1% gain in moisture content (as determined by a loss on drying test) will decrease the API concentration of the final blend at least 1% LC. The effect of pre-blend solid losses increases with their degree of superpotency. This work supports Quality by Design by providing a rational method to set the process design space to minimize blend potency losses. When an overage is necessary, the model can help justify it by providing a quantitative, first-principles understanding of the sources of potency loss. The analysis is applicable to other manufacturing processes where the primary sources of potency loss are net water gain and/or mass losses.

  9. Stable carbon isotopic composition of gasolines determined by isotope ratio monitoring gas chromatography mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Smallwood, B.J.; Philp, R.P.; Allen, J.D. [University of Oklahoma, Norman, OK (United States). School of Geology and Geophysics

    2002-07-01

    A large number of underground gasoline storage facilities in the United States continuously leak gasoline into the subsurface, which makes gasoline a major groundwater contaminant. Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) are used currently to characterize contaminated groundwater and soils. Correlations of contaminants with suspected source(s) are extremely difficult by these techniques because many gasolines have similar hydrocarbon distributions. The present study applied the technique of isotope ratio monitoring gas chromatography-mass spectrometry (irmGC-MS) to 19 gasoline samples from different areas of the USA. This allows a much better correlation of gasoline contaminants to source. Data obtained indicate a wide range of {sup {delta}}{sup 13}C values for 16 ubiquitous compounds in the gasolines. The majority of samples could be distinguished from each other on the basis of {sup {delta}}{sup 13}C hydrocarbon composition. The oxygenated additive methyl tertiary butyl ether (MTBE) was present in ten of the gasolines analyzed, and had a relatively narrow range of {sup {delta}}{sup 13}C values (-30.4 to -28.3 per mille). Preliminary investigations were also made to determine the extent of carbon isotopic fractionation after simple water washing and evaporation experiments. Results indicate that the majority of compounds did not undergo significant carbon isotopic fractionation as a result of these processes. (author)

  10. Daily cortisol production rate in man determined by stable isotope dilution/mass spectrometry

    International Nuclear Information System (INIS)

    Esteban, N.V.; Loughlin, T.; Yergey, A.L.; Zawadzki, J.K.; Booth, J.D.; Winterer, J.C.; Loriaux, D.L.

    1991-01-01

    Growth retardation as well as the development of Cushingoid features in adrenally insufficient patients treated with the currently accepted replacement dose of cortisol (33-41 mumol/day.m2; 12-15 mg/m2.day) prompted us to reevaluate the cortisol production rate (FPR) in normal subjects and patients with Cushing's syndrome, using a recently developed thermospray liquid chromatography-mass spectrometry method. The stable isotope [9,12,12-2H3]cortisol was infused continuously for 31 h at about 5% of the anticipated FPR. Blood samples were obtained at 20-min intervals for 24 h, spun, and pooled in 4-h groups. Tracer dilution in plasma was determined by liquid chromatography/mass spectrometry. The method was validated with controlled infusions in 6 patients with adrenal insufficiency. Results from 12 normal volunteers revealed a FPR of 27.3 +/- 7.5 mumol/day (9.9 +/- 2.7 mg/day) or 15.7 mumol/day.m2; 5.7 mg/m2. day. A previously unreported circadian variation in FPR was observed. Patients with Cushing's syndrome demonstrated unequivocal elevation of FPR and cortisol concentration correlated during each sample period in normal volunteers, indicating that cortisol secretion, rather than metabolism, is mainly responsible for changes in plasma cortisol. Our data suggest that the FPR in normal subjects may be lower than previously believed

  11. The timing and pattern of biotic recovery following the end-Permian mass extinction

    Science.gov (United States)

    Chen, Zhong-Qiang; Benton, Michael J.

    2012-06-01

    The aftermath of the great end-Permian period mass extinction 252 Myr ago shows how life can recover from the loss of >90% species globally. The crisis was triggered by a number of physical environmental shocks (global warming, acid rain, ocean acidification and ocean anoxia), and some of these were repeated over the next 5-6 Myr. Ammonoids and some other groups diversified rapidly, within 1-3 Myr, but extinctions continued through the Early Triassic period. Triassic ecosystems were rebuilt stepwise from low to high trophic levels through the Early to Middle Triassic, and a stable, complex ecosystem did not re-emerge until the beginning of the Middle Triassic, 8-9 Myr after the crisis. A positive aspect of the recovery was the emergence of entirely new groups, such as marine reptiles and decapod crustaceans, as well as new tetrapods on land, including -- eventually -- dinosaurs. The stepwise recovery of life in the Triassic could have been delayed either by biotic drivers (complex multispecies interactions) or physical perturbations, or a combination of both. This is an example of the wider debate about the relative roles of intrinsic and extrinsic drivers of large-scale evolution.

  12. Determination of Groundwater Flows Pattern in Surakarta Region Using the Activity Ratio of Tritium

    International Nuclear Information System (INIS)

    Wisjachudin Faisal; Agus Sulistyono; Brotopuspito, Kirbani Sri; Budi Legowo

    2002-01-01

    Tritium activity analysis on groundwater samples has been carried out at 13 different locations in Surakarta regency in order to determine the groundwater flow pattern. Tritium activity in the groundwater is measured by LSC (Liquid Scintillation Counter) Tri-Carb 2700TR Measurement of the optimum activity is done on sample volume ratio with cocktail 7.4 : 12.6 in operation 0.5 - 4.5 keV. The highest result fulfilled in the location of Lor In Hotel for 1566 dpm and the lowest is in the location of Kadipiro for 0.03 dpm. Those data have shown that groundwater flow come from western area to eastern area of Surakarta city. (author)

  13. Determination of displacements and their derivatives from 3D fringe patterns via extended monogenic phasor method

    Science.gov (United States)

    Sciammarella, Cesar A.; Lamberti, Luciano

    2018-05-01

    For 1D signals, it is necessary to resort to a 2D abstract space because the concept of phase utilized in the retrieval of fringe pattern analysis information relies on the use of a vectorial function. Fourier and Hilbert transforms provide in-quadrature signals that lead to the very important basic concept of local phase. A 3D abstract space must hence be generated in order to analyze 2D signals. A 3D vector space in a Cartesian complex space is graphically represented by a Poincare sphere. In this study, the extension of the associated spaces is extended to 3D. A 4D hypersphere is defined for that purpose. The proposed approach is illustrated by determining the deformations of the heart left ventricle.

  14. Multielement determination of rare earth elements in rock sample by liquid chromatography / inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Hamanaka, Tadashi; Itoh, Akihide; Itoh, Shinya; Sawatari, Hideyuki; Haraguchi, Hiroki.

    1995-01-01

    Rare earth elements in geological standard rock sample JG-1 (granodiolite)issued from the Geological Survey of Japan have been determined by a combined system of liquid chromatography and inductively coupled plasma mass spectrometry. (author)

  15. Determination of rare earth elements by liquid chromatographic separation using inductively coupled plasma mass spectrometric detection

    International Nuclear Information System (INIS)

    Braverman, D.S.

    1992-01-01

    High-performance liquid chromatography (HPLC) is used to separate the rare earth elements (REEs) prior to detection by inductively coupled plasma mass spectrometry (ICP-MS). The use of HPLC-ICP-MS in series combines the separation power and speed of HPLC with the sensitivity, isotopic selectivity and speed of ICP-MS. The detection limits for the REEs are in the sub-ng ml -1 range and the response is linear over four orders of magnitude. A preliminary comparison of isotope dilution and external standard results for the determination of REEs in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM 1633a) Fly Ash is presented. (author)

  16. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    International Nuclear Information System (INIS)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H.

    2005-12-01

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here

  17. Multidimensional phase space methods for mass measurements and decay topology determination

    Science.gov (United States)

    Altunkaynak, Baris; Kilic, Can; Klimek, Matthew D.

    2017-02-01

    Collider events with multi-stage cascade decays fill out the kinematically allowed region in phase space with a density that is enhanced at the boundary. The boundary encodes all available information as regards the spectrum and is well populated even with moderate signal statistics due to this enhancement. In previous work, the improvement in the precision of mass measurements for cascade decays with three visible and one invisible particles was demonstrated when the full boundary information is used instead of endpoints of one-dimensional projections. We extend these results to cascade decays with four visible and one invisible particles. We also comment on how the topology of the cascade decay can be determined from the differential distribution of events in these scenarios.

  18. Determination of Chlorpyrifos in Human Blood by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Xinhua Dai

    2017-01-01

    Full Text Available Gas chromatography-mass spectrometry method was developed for the qualitative and quantitative analyses of chlorpyrifos in human blood samples. The chlorpyrifos and parathion (internal standard in human blood were extracted with a mixed solvent of hexane and acetonitrile. Chlorpyrifos was well separated from the internal standard. The linear range of chlorpyrifos was 0.01–2 μg/ml in blood. The limit of detection and limit of quantification were estimated at 0.002 and 0.01 μg/ml, respectively. The inter- and intra-day precisions, accuracy, and recovery were assessed to verify this method. The results showed that the developed method is rapid, sensitive, and reliable. It is suitable for the determination of chlorpyrifos in forensic toxicological analysis and clinical diagnosis.

  19. Gas Chromatographic Mass Spectrometric Determination of Myo-inositol in Humans Utilizing a Deuterated Internal Standard

    DEFF Research Database (Denmark)

    Andersen, Jan Rud; Larsen, Elfinn; Harbo, Helge

    1982-01-01

    The isotopic dilution technique was used for determining the content of myo-inositol in human urine, plasma and haemolysed erythrocyte samples. A deuterated myo-inositol, synthesized from inosose-2 by base-catalysed exchange of hydrogens by deuterium, followed by reduction of the inosose with 2H2......, was added as internal standard to the samples at an early stage in the analytical procedure. After separation and derivatization to the hexa-acetate, the gas chromatographic mass spectrometric analysis was carried out. A 25 m fused silica capillary column coated with methyl silicone was used, and the ions...... selected for monitoring were m/z 210 and m/z 214, which are characteristic and abundant fragment ions from unlabelled and hexadeuterated myo-inositolhexa-acetate, respectively. Calibration curves from water, urine, plasma and haemolysed erythrocytes show parallel, linear responses in the ratio between...

  20. Molecular weight determination of bisbenzyl-isoquinoline alkaloids by 252Cf-plasma desorption mass spectrometer

    International Nuclear Information System (INIS)

    Kohno, Hiroyuki; Tatsunami, Shinobu; Hiroi, Tomoko; Kouyama, Hiroshi; Taniguchi, Masashi; Yago, Nagasumi; Nakamura, Iwao

    1995-01-01

    Bisbenzylisoquinoline alkaloids of Stephania cepharantha have been used for various clinical purposes and recently reevaluated as stimulators of interleukin secretion in tissues. We analyzed molecular stuctures of bisbenzylisoquinoline alkaloids by determining their molecular weights using the 252 Cf-plasma desorption mass spectrometry (PDMS). The spectra were accumulated for 500 000 fission events. The acceleration voltage used here was 15 kV. Samples were analyzed using nitrocellulose-coated sample targets. Of the 5 alkaloids studied here, cepharanthine gave a main peak of molecular weight of 606.1 for the theoretical molecular weight of 606.7. The other minor peaks were considered to be demethylated fragment ions. 252 Cf-PDMS should be quite useful in studying structure, metabolism and pharmacokinetics of various drugs with extremely low coefficients of variation. (author)

  1. Determination of dapsone in meat and milk by liquid chromatography tandem mass spectrometry

    International Nuclear Information System (INIS)

    Hadjigeorgiou, M.; Papachrysostomou, Ch.; Theodorou, Z.; Kanari, P.; Constantinou, S.

    2009-01-01

    Within the EU the use of dapsone (4,4-diaminodiphenylsulfone) is prohibited in food-producing animals and consequently it's included in the Annex IV of the Directive 90/2377/EC. A quantitative confirmatory method has been developed and validated according to the criteria defined in the Commission Decision 2002/657/EC, for the determination of dapsone in meat and milk. Samples, after homogenization in alkaline conditions and organic solvent extraction, were purified on silica gel solid phase extraction cartridges. The eluate was evaporated and redissolved in mobile phase and was analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionisation (ESI) using deuterium labelled Sulphadimidine-d7 as internal standard. The calculated value for, decision limit, CCα is 0.12 μg kg -1 , and the detection capability; CCβ value is 0.16 μg kg -1

  2. Multidimensional phase space methods for mass measurements and decay topology determination

    Energy Technology Data Exchange (ETDEWEB)

    Altunkaynak, Baris [Northeastern University, Department of Physics, Boston, MA (United States); Kilic, Can; Klimek, Matthew D. [The University of Texas at Austin, Theory Group, Department of Physics and Texas Cosmology Center, Austin, TX (United States)

    2017-02-15

    Collider events with multi-stage cascade decays fill out the kinematically allowed region in phase space with a density that is enhanced at the boundary. The boundary encodes all available information as regards the spectrum and is well populated even with moderate signal statistics due to this enhancement. In previous work, the improvement in the precision of mass measurements for cascade decays with three visible and one invisible particles was demonstrated when the full boundary information is used instead of endpoints of one-dimensional projections. We extend these results to cascade decays with four visible and one invisible particles. We also comment on how the topology of the cascade decay can be determined from the differential distribution of events in these scenarios. (orig.)

  3. Simultaneous Determination of Alkoxyalcohols in Wet Wipes Using Static Headspace Gas Chromatography and Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So Jin; Pyo, Hee Soo; Chung, Bong Chul; Lee, Jeon Gae [KIST, Seoul (Korea, Republic of); Kim, Hai Dong [Kyung Hee University, Seoul (Korea, Republic of)

    2014-09-15

    Alkoxyalcohols are used as solvents or preservatives in various consumer products such as wet wipes. The metabolites of alkoxyalcohols are known to be chronically toxic and carcinogenic to animals. Thus, an analytical method is needed to monitor alkoxyalcohols in wet wipes. The aim of this study was to develop a simultaneous analytical method for 14 alkoxyalcohols using headspace gas chromatography coupled with mass spectrometry to analyze the wet wipes. This method was developed by comparing with various headspace extraction parameters. The linear calibration curves were obtained for the method (r2 > 0.995). The limit of detection of alkoxyalcohols ranged from 2 to 200 ng mL-1. The precision of the determinative method was less than 18.20% coefficient of variation both intra and inter days. The accuracy of the method ranged from 82.86% to 119.83%. (2-Methoxymethylethoxy)propanol, 2-phenoxyethanol, and 1-phenoxy-2-propanol were mainly detected in wet wipes.

  4. Determination of long-chain fatty acids in serum by gas chromatography coupled to mass spectrometry

    International Nuclear Information System (INIS)

    Nuevas Paz, Lauro; Camayd Viera, Ivette

    2014-01-01

    The quantification of long-chain fatty acids is fundamental for the diagnosis of several peroxisome disorders, particularly those in which the β-oxidation peroxisome of fatty acids is affected. In this work the implementation of an analytical method for the determination of these markers in serum by gas chromatography coupled to mass spectrometry is described. Besides, samples from patients with a diagnostic impression of adrenoleukodystrophy linked to the X chromosome were analyzed. The necessary experimental conditions were achieved for the separation and quantification of C22:0, C24:0 and C26:0 fatty acids in serum, which are biochemical markers of various peroxisome diseases. The application of this method allowed confirming the diagnosis of three patients with a diagnostic impression of adrenoleukodystrophy linked to the X chromosome. The application of the method in daily practice will allow the Cuban medical system to count on a new laboratory parameter for the diagnosis of peroxisome disorders

  5. Technique for mass-spectrometric determination of moisture content in fuel elements and fuel element claddings

    International Nuclear Information System (INIS)

    Kurillovich, A.N.; Pimonov, Yu.I.; Biryukov, A.S.

    1988-01-01

    A technique for mass-spectroimetric determination of moisture content in fuel elements and fuek claddings in the 2x10 -4 -1.5x10 -2 g range is developed. The relative standard deviation is 0.13. A character of moisture extraction from oxide uranium fuels in the 20-700 deg C temperature range is studied. Approximately 80% of moisture is extracted from the fuels at 300 deg C. The moisture content in fuel elements with granular uranium oxide fuels is measured. Dependence of fuel element moisture content on conditions of hot vacuum drying is shown. The technique permits to optimize the fuel element fabrication process to decrease the moisture content in them. 4 refs.; 3 figs.; 2 tabs

  6. Determination of the first ionization potential of actinides by resonance ionization mass spectroscopy

    International Nuclear Information System (INIS)

    Koehler, S.; Albus, F.; Dibenberger, R.; Erdmann, N.; Funk, H.; Hasse, H.; Herrmann, G.; Huber, G.; Kluge, H.; Nunnemann, M.; Passler, G.; Rao, P.M.; Riegel, J.; Trautmann, N.; Urban, F.

    1995-01-01

    Resonance ionization mass spectroscopy (RIMS) is used for the precise determination of the first ionization potential of transuranium elements. The first ionization potentials (IP) of americium and curium have been measured for the first time to IP Am =5.9738(2) and IP Cm =5.9913(8) eV, respectively, using only 10 12 atoms of 243 Am and 248 Cm. The same technique was applied to thorium, neptunium, and plutonium yielding IP T H =6.3067(2), IP N P =6.2655(2), and IP Pu =6.0257(8) eV. The good agreement of our results with the literature data proves the precision of the method which was additionally confirmed by the analysis of Rydberg seris of americium measured by RIMS. copyright American Institute of Physics 1995

  7. Genetic determinants of serum vitamin B12 and their relation to body mass index

    DEFF Research Database (Denmark)

    Allin, Kristine H.; Friedrich, Nele; Pietzner, Maik

    2017-01-01

    for associations between (1) serum vitamin B12 levels and body mass index (BMI), (2) genetic variants and serum vitamin B12 levels, and (3) genetic variants and BMI. The effect of a genetically determined decrease in serum vitamin B12 on BMI was estimated by instrumental variable regression. Decreased serum......Lower serum vitamin B12 levels have been related to adverse metabolic health profiles, including adiposity. We used a Mendelian randomization design to test whether this relation might be causal. We included two Danish population-based studies (ntotal = 9311). Linear regression was used to test...... vitamin B12 associated with increased BMI (P vitamin B12 associated variants associated strongly with serum vitamin B12 (P vitamin B12...

  8. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H

    2005-12-15

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here.

  9. Indirect effects of land-use legacies determine tree colonization patterns in abandoned heathland

    DEFF Research Database (Denmark)

    Kepfer Rojas, Sebastian; Verheyen, Kris; Johannsen, Vivian Kvist

    2015-01-01

    of tree/shrubs in the heathland. Further, we used high-resolution LiDAR data to classify the vegetation and identify forest patches. In the analysis, we first used a logistic mixed model to test whether colonization of tree and shrub species differed between areas with different land-use history......Questions How do land-use legacies and distance to forest patches influence tree colonization at a post-agricultural heathland? Are colonizing species with different life-history traits affected differently by these factors? Is the effect of increased nutrient availability from land-use legacies...... and whether it was influenced by the distance to forest patches and life-history traits (seed mass) of colonizing species. Then, to determine how different factors influence colonization, we explored the direct and indirect relationships among nutrient availability, density of adult trees, canopy cover, cover...

  10. Active renin mass concentration to determine aldosterone-to-renin ratio in screening for primary aldosteronism

    Directory of Open Access Journals (Sweden)

    Corbin F

    2011-07-01

    Full Text Available François Corbin1, Pierre Douville2, Marcel Lebel3 1Division of Biochemistry, l'Université de Sherbrooke, Sherbrooke, Quebec, Canada; 2Division of Biochemistry; 3Division of Nephrology, L'Hôtel-Dieu de Québec Hospital and l'Université Laval, Quebec, CanadaBackground: Active renin mass concentration (ARC is independent of the endogenous level of angiotensinogen, and less variable and more reproducible than plasma renin activity. Reference values for the aldosterone-to-renin ratio (ARR using ARC are still undefined. The objective of the present study was to determine the threshold of ARR using ARC measurement to screen for primary aldosteronism.Methods: A total of 211 subjects were included in the study, comprising 78 healthy normotensive controls, 95 patients with essential hypertension, and 38 patients with confirmed primary aldosteronism (20 with surgery-confirmed aldosterone-producing adenoma and 18 with idiopathic adrenal hyperplasia. Blood samples were drawn from ambulatory patients and volunteers in the mid-morning without specific dietary restriction for measuring plasma aldosterone concentration, ARC, and serum potassium.Results: Most normotensive controls and essential hypertension patients had ARR results below 100 pmol/ng, a value which corresponded to 3.3 times the median of these two groups.Conclusion: Patients with ARR values above this level should be considered for further investigation (confirmatory tests or for repeat testing should ARR values be borderline. This study indicates that ARC can be used reliably in determining ARR for primary aldosteronism screening.Keywords: primary aldosteronism, active renin mass concentration, aldosterone-to-renin ratio

  11. Determination of Coefficient of Thermal Expansion (CTE) of 20MPa Mass Concrete Using Granite Aggregate

    Science.gov (United States)

    Chee Siang, GO

    2017-07-01

    Experimental test was carried out to determine the coefficient of thermal expansion (CTE) value of 20MPa mass concrete using granite aggregate. The CTE value was established using procedure proposed by Kada et al. 2002 in determining the magnitude of early-ages CTE through laboratory test which is a rather accurate way by eliminating any possible superimposed effect of others early-age thermal deformation shrinkages such as autogenous, carbonation, plastic and drying shrinkage. This was done by submitting granite concrete block samples instrumented with ST4 vibrating wire extensometers to thermal shocks. The response of the concrete samples to this shock results in a nearly instantaneous deformation, which are measured by the sensor. These deformations, as well as the temperature signal, are used to calculate the CTE. By repeating heat cycles, the variation in the early-ages of concrete CTE over time was monitored and assessed for a period of upto 7 days. The developed CTE value facilitating the verification and validation of actual maximum permissible critical temperature differential limit (rather than arbitrarily follow published value) of cracking potential. For thick sections, internal restraint is dominant and this is governed by differentials mainly. Of the required physical properties for thermal modelling, CTE is of paramount importance that with given appropriate internal restraint factor the condition of cracking due to internal restraint is governs by equation, ΔTmax= 3.663ɛctu / αc. Thus, it can be appreciated that an increase in CTE will lower the maximum allowable differential for cracking avoidance in mass concrete while an increase of tensile strain capacity will increase the maximum allowable temperature differential.

  12. Multi-signal sedimentation velocity analysis with mass conservation for determining the stoichiometry of protein complexes.

    Directory of Open Access Journals (Sweden)

    Chad A Brautigam

    Full Text Available Multi-signal sedimentation velocity analytical ultracentrifugation (MSSV is a powerful tool for the determination of the number, stoichiometry, and hydrodynamic shape of reversible protein complexes in two- and three-component systems. In this method, the evolution of sedimentation profiles of macromolecular mixtures is recorded simultaneously using multiple absorbance and refractive index signals and globally transformed into both spectrally and diffusion-deconvoluted component sedimentation coefficient distributions. For reactions with complex lifetimes comparable to the time-scale of sedimentation, MSSV reveals the number and stoichiometry of co-existing complexes. For systems with short complex lifetimes, MSSV reveals the composition of the reaction boundary of the coupled reaction/migration process, which we show here may be used to directly determine an association constant. A prerequisite for MSSV is that the interacting components are spectrally distinguishable, which may be a result, for example, of extrinsic chromophores or of different abundances of aromatic amino acids contributing to the UV absorbance. For interacting components that are spectrally poorly resolved, here we introduce a method for additional regularization of the spectral deconvolution by exploiting approximate knowledge of the total loading concentrations. While this novel mass conservation principle does not discriminate contributions to different species, it can be effectively combined with constraints in the sedimentation coefficient range of uncomplexed species. We show in theory, computer simulations, and experiment, how mass conservation MSSV as implemented in SEDPHAT can enhance or even substitute for the spectral discrimination of components. This should broaden the applicability of MSSV to the analysis of the composition of reversible macromolecular complexes.

  13. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  14. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dron, J.; El Haddad, I.; Temime-Roussel, B.; Wortham, H.; Marchand, N. [Univ Aix Marseille, CNRS, Lab Chim Provence, Equipe Instrumentat and React Atmospher, UMR 6264, F-13331 Marseille 3 (France); Jaffrezo, J.L. [Univ Grenoble 1, CNRS, UMR 5183, Lab Glaciol and Geophys Environm, F-38402 St Martin Dheres (France)

    2010-07-01

    The functional group composition of various organic aerosols (OA) is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCIMS/MS). The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R' respectively) and precursor ion (nitro groups, R-NO{sub 2}) scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA) produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular) to 13.5% (o-xylene photooxidation) of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France) during a strong winter pollution event. The three functional groups under study account for a total functionalization rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60%. Finally, examples of functional

  15. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dron

    2010-08-01

    Full Text Available The functional group composition of various organic aerosols (OA is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCI-MS/MS. The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R´ respectively and precursor ion (nitro groups, R-NO2 scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular to 13.5% (o-xylene photooxidation of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France during a strong winter pollution event. The three functional groups under study account for a total functionalisation rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60

  16. Generation, language, body mass index, and activity patterns in Hispanic children.

    Science.gov (United States)

    Taverno, Sharon E; Rollins, Brandi Y; Francis, Lori A

    2010-02-01

    The acculturation hypothesis proposes an overall disadvantage in health outcomes for Hispanic immigrants with more time spent living in the U.S., but little is known about how generational status and language may influence Hispanic children's relative weight and activity patterns. To investigate associations among generation and language with relative weight (BMI z-scores), physical activity, screen time, and participation in extracurricular activities (i.e., sports, clubs) in a U.S.-based, nationally representative sample of Hispanic children. Participants included 2012 Hispanic children aged 6-11 years from the cross-sectional 2003 National Survey of Children's Health. Children were grouped according to generational status (first, second, or third), and the primary language spoken in the home (English versus non-English). Primary analyses included adjusted logistic and multinomial logistic regression to examine the relationships among variables; all analyses were conducted between 2008 and 2009. Compared to third-generation, English speakers, first- and second-generation, non-English speakers were more than two times more likely to be obese. Moreover, first-generation, non-English speakers were half as likely to engage in regular physical activity and sports. Both first- and second-generation, non-English speakers were less likely to participate in clubs compared to second- and third-generation, English speakers. Overall, non-English-speaking groups reported less screen time compared to third-generation, English speakers. The hypothesis that Hispanics lose their health protection with more time spent in the U.S. was not supported in this sample of Hispanic children. Copyright 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  17. Multi-elemental determination of trace elements in deep seawater by inductively coupled plasma mass spectrometry with resin preconcentration

    International Nuclear Information System (INIS)

    Sumida, Takashi; Nakazato, Tetsuya; Tao, Hiroaki

    2003-01-01

    A miniaturized column (ca. 3 mm i.d., 40 mm length), packed with a chelating resin (0.2 g) with iminodiacetic acid groups (Muromac A-1), was tested for the preconcentration of trace elements in seawater. After preconcentration, the column was washed with ammonium acetate buffer (pH 5.5) and water to remove the major elements, such as Ca and Mg, and was then eluted with 4 ml of 2 mol l -1 nitric acid. Twenty-six trace elements were determined by inductively coupled plasma mass spectrometry and inductively coupled plasma emission spectrometry. The necessary volume of the seawater sample was only 200 ml. The recoveries for most of the elements tested were over 90%, although those for Al, V and Th were around 70%. The trueness and precision were evaluated by analyzing a standard reference material of seawater (NASS-4, NRC Canada). The observed values obtained with the present method showed good agreement with the certified values. The present method was also applied to deep seawater samples collected at Muroto, Japan. A difference in the rare earth element pattern, especially the Ce anomaly, between the deep seawater sample and the surface seawater sample was observed, as well as the differences of the concentrations of many trace elements. (author)

  18. Determination of 36Cl/Cl ratio in ground water using the accelerator mass spectrometry technique

    International Nuclear Information System (INIS)

    Sharma, Suman; Deodhar, A.S.; Saravana Kumar, U.; Surendran, P.; Shrivastava, A.; Gupta, A.K.; Nair, J.P.; Yadav, M.L.; Hemalatha, M.; Sparrow, H.; Mahata, K.; Thomas, R.G.; Bhagwat, P.V.; Kailas, S.; Kale, R.M.

    2009-01-01

    The Accelerator Mass Spectrometry (AMS) programme using the 14 MV Pelletron Accelerator at Mumbai has been initiated with major emphasis on the determination of 36 Cl in water samples, of interest to hydrology and environment. In order to carry out the AMS measurement, a beam chopper to cut down beam intensity by a factor of 20 has been developed and commissioned. A multi-anode gas -si detector has been built to separate 36 Cl from the interfering 36 S. A new TPS system has been procured to operate the machine in the GVM mode. Standard and blank samples from Prime lab, Purdue have been employed in these measurements to standardise the technique for 36 Cl/Cl ratio determination. The detector was calibrated using the stable 35,37 Cl ions. The background 36 Cl in the system has been measured using the blank sample from Purdue and it was estimated that the ratio of 36 Cl/Cl was of the order of 10 -13 in the present setup. Ground water samples collected from South India were converted to AgCl and put in the SNICS ion source for the AMS measurements. These ground water samples, with 14 C content estimated to be in the range of 1 to 4 pMC indicate that the samples may be more than 35,000 years old. Using the AMS technique we have determined the 36 Cl/Cl ratio values for these ground water samples. They are found to range between 2 to 5 x 10 -12 . Additional measurements are planned to determine the age of the water samples and to understand the reasons for the observed high values of 36 Cl in these samples. (author)

  19. Resin bead-thermal ionization mass spectrometry for determination of plutonium concentration in irradiated fuel dissolver solution

    International Nuclear Information System (INIS)

    Paul, Sumana; Shah, R.V.; Aggarwal, S.K.; Pandey, A.K.

    2015-01-01

    Determination of isotopic composition (IC) and concentration of plutonium (Pu) is necessary at various stages of nuclear fuel cycle which involves analysis of complex matrices like dissolver solution of irradiated fuel, nuclear waste stream etc. Mass spectrometry, e.g. thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) are commonly used for determination of IC and concentration of plutonium. However, to circumvent matrix interferences, efficient separation as well as preconcentration of Pu is required prior to mass spectrometric analysis. Purification steps employing ion-exchange resins are widely used for the separation of Pu from dissolver solution or from mixture of other actinides e.g. U, Am. However, an alternative way is to selectively preconcentrate Pu on a resin bead, followed by direct loading of the bead on the filament of thermal ionization mass spectrometer

  20. Determination of Areas Susceptible to Landsliding Using Spatial Patterns of Rainfall from Tropical Rainfall Measuring Mission Data, Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Renato Fontes Guimarães

    2017-10-01

    Full Text Available Spatial patterns of shallow landslide initiation reflect both spatial patterns of heavy rainfall and areas susceptible to mass movements. We determine the areas most susceptible to shallow landslide occurrence through the calculation of critical soil cohesion and spatial patterns of rainfall derived from TRMM (Tropical Rainfall Measuring Mission data for Paraty County, State of Rio de Janeiro, Brazil. Our methodology involved: (a creating the digital elevation model (DEM and deriving attributes such as slope and contributing area; (b incorporating spatial patterns of rainfall derived from TRMM into the shallow slope stability model SHALSTAB; and (c quantitative assessment of the correspondence of mapped landslide scars to areas predicted to be most prone to shallow landsliding. We found that around 70% of the landslide scars occurred in less than 10% of the study area identified as potentially unstable. The greatest concentration of landslides occurred in areas where the root strength of vegetation is an important contribution to slope stability in regions of orographically-enhanced rainfall on the coastal topographic flank. This approach helps quantify landslide hazards in areas with similar geomorphological characteristics, but different spatial patterns of rainfall.

  1. Patterns of Growth in Early Childhood and Infectious Disease and Nutritional Determinants.

    Science.gov (United States)

    Black, Robert E

    2017-01-01

    The physical growth of young children in low- and middle-income countries is reduced compared to international standards. The deviations in growth in both weight and height are greatest in the first 2 years of life and this has serious consequences for child mortality, development, adult stature, and health. The determinants of these patterns of growth faltering include intergenerational factors, such as maternal height, short birth interval, and conditions in pregnancy, including maternal underweight and anemia. These factors contribute to fetal growth restriction and premature delivery, which put many infants on a different growth trajectory. Postnatal exposure to microbes resulting in diarrhea and febrile infectious diseases and poor quality diet further compromise growth. Determinants of growth faltering after birth vary by setting and are not independent of each other. For example, the adverse effects of diarrhea on growth may be mitigated by a high-quality diet. Global estimates suggest that 25% of stunting can be attributed to fetal growth restriction and even more in countries in South Asia with a high prevalence of low birth weight. Infectious diseases may contribute a similar amount and subclinical enteric infections can result in intestinal dysfunction with adverse effects on nutrition and growth. Dietary factors, especially consumption of complementary foods of insufficient quality, have a paramount role in growth faltering in the critical period of infancy. © 2017 Nestec Ltd., Vevey/S. Karger AG, Basel.

  2. [Simultaneous determination of ten organotin compounds in polyvinyl chloride plastics using gas chromatography-mass spectrometry].

    Science.gov (United States)

    Li, Ying; Li, Bin; Liu, Li; Zhang, Chen; Wu, Jingwu; Liu, Zhihong; Li, Xintian

    2009-01-01

    A rapid and effective gas chromatography coupled with mass spectrometry method has been developed systematically and studied for the simultaneous determination of 10 organotin compounds, dibutyltin-dichloride (DBT), n-butyltin-trichloride (MBT), triethyltinchloride (TET), fentin-chloride (TPhT), chlorotributylstannane (TBT), tri-n-propyltinchloride (TPrT), diphenyltin-dichloride (DPhT), tetrabutyltin (TeBT), di-n-octyltin-dichloride (DOT), phenyltin trichloride (MPhT)), in polyvinyl chloride (PVC) plastics. The PVC sample was dissolved with tetrahydrofuran and the polymer in the sample was precipitated with methanol, and then the target compounds were derivatized with sodium tetraethylborate and extracted with hexane under ultrasonication. The qualitative and quantitative analysis were carried out by GC-MS and the total ion chromatogram and selected ion chromatogram were obtained. The derivatization and extraction conditions, such as the derivatization time, derivatization pH value, dosages of derivatization reagent and precipitation reagent were optimized. The good linearities, recoveries and precisions were obtained. The linearity ranges were 0.5 - 50 mg/L. The linearity correlation coefficients of 10 organotin compounds were between 0.997 8 and 0.999 7. The average recoveries were 84.23% - 109.1% with relative standard deviations of 4.24% - 10.75%. The established method has been successfully applied to the determination of organotin compounds in PVC plastics.

  3. Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Yim, Yong Hyeon; Park, Ji Youn; Han, Myung Sub; Park, Mi Kyung; Kim, Byung Joo; Lim, Young Ran; Hwang, Eui Jin; So, Hun Young

    2005-01-01

    A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties

  4. Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Yong Hyeon; Park, Ji Youn; Han, Myung Sub; Park, Mi Kyung; Kim, Byung Joo; Lim, Young Ran; Hwang, Eui Jin; So, Hun Young [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2005-03-15

    A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.

  5. Accelerator mass spectrometry 14C determination in CO2 produced from laser decomposition of aragonite.

    Science.gov (United States)

    Rosenheim, Brad E; Thorrold, Simon R; Roberts, Mark L

    2008-11-01

    The determination of (14)C in aragonite (CaCO(3)) decomposed thermally to CO(2) using an yttrium-aluminum-garnet doped neodymium laser is reported. Laser decomposition accelerator mass spectrometry (LD-AMS) measurements reproduce AMS determinations of (14)C from the conventional reaction of aragonite with concentrated phosphoric acid. The lack of significant differences between these sets of measurements indicates that LD-AMS radiocarbon dating can overcome the significant fractionation that has been observed during stable isotope (C and O) laser decomposition analysis of different carbonate minerals. The laser regularly converted nearly 30% of material removed into CO(2) despite it being optimized for ablation, where laser energy breaks material apart rather than chemically altering it. These results illustrate promise for using laser decomposition on the front-end of AMS systems that directly measure CO(2) gas. The feasibility of such measurements depends on (1) the improvement of material removal and/or CO(2) generation efficiency of the laser decomposition system and (2) the ionization efficiency of AMS systems measuring continuously flowing CO(2).

  6. [Determination of endogenous agmatine in rat plasma by isotope dilution-gas chromatography-mass spectrometry].

    Science.gov (United States)

    Qiu, Zhongli; Lin, Ying; Xiong, Zhili; Xie, Jianwei

    2014-07-01

    A method for the determination of endogenous agmatine in rat plasma was developed by isotope dilution-gas chromatography-negative chemical ionization mass spectrometry (GC-NCI/MS). The plasma samples were analyzed after protein precipitation, evaporation, derivatization by hexafluoroacetone (HFAA), and clean-up on a Florisil SPE column. The GC-MS analysis utilized stable isotope d8-agmatine as internal standard. The samples after treatme were tested by negative chemical ionization with selected ion monitoring (SIM) which was set at m/z 492 (molecular ion of agmatine) and m/z 500 (molecular ion of internal standard). The limit of detection (LOD) of agmatine standard solution was 0.005 7 ng/mL. The calibration curve of the agmatine spiked in rat plasma showed a good linear relationship at the range of 1.14-57.0 ng/mL (r = 0.997). The recoveries of agmatine spiked in rat plasma ranged from 92.3% to 109.8%. Inter-day and intra-day precisions were less than 15%. The average concentration level of agmatine in rat plasma was (22 +/- 9) ng/mL, and there was no significant difference between male and female SD rats (p > 0.05). The method is high sensitive and specific, and can be used for the determination of endogenous agmatine in plasma. It provides a strong support for the subsequent research of agmatine.

  7. [Determination of five representative ultraviolet filters in water by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Ding, Yiran; Huang, Yun; Zhao, Tingting; Cai, Qian; Luo, Yu; Huang, Bin; Zhang, Yuxia; Pan, Xuejun

    2014-06-01

    A method for the determination of five representative organic UV filters: ethylhexyl methoxycinnamate (EHMC), benzophenone-3 (BP-3), 4-methylbenzylidene camphor (4-MBC), octocrylene (OC), homosalate (HMS) in water was investigated. The method was ased on derivatization, solid phase extraction (SPE), followed by determination with gas chromatography-mass spectrometry (GC-MS). The variables involved in the derivatization of BP-3 and HMS were optimized, and SPE conditions were studied. For derivatization, 100 microL N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) was used as derivatization reagent and reacted with BP-3 and HMS at 100 degrees C for 100 min. For SPE, the pH value of water sample was adjusted to 3-5. The Oasis HLB cartridges were employed and the solution of ethyl acetate and dichloromethane (1 : 1, v/v) was used as the eluting solvent, and good recoveries of the target compounds were obtained. The limits of detection (LODs) and the limits of quantification (LOQs) for the five target compounds in water samples were 0.5-1.2 ng/L and 1.4-4.0 ng/L, respectively. The recoveries of spiked water samples were 87.85%-102.34% with good repeatability and reproducibility (RSD < 5%, n = 3) for all the target compounds. Finally, the validated method was applied to analysis the representative UV filters in water samples collected from a wastewater treatment plant in Kunming city of Yunnan province.

  8. Accurate determination of silver nanoparticles in animal tissues by inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Veverková, Lenka [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacky University, 17.listopadu 12, CZ 771 46 Olomouc (Czech Republic); Hradilová, Šárka [Regional Centre of Advanced Technologies and Materials, Department of Physical Chemistry, Faculty of Science, Palacky University, 17.listopadu 12, CZ 771 46 Olomouc (Czech Republic); Milde, David, E-mail: david.mlde@upol.cz [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacky University, 17.listopadu 12, CZ 771 46 Olomouc (Czech Republic); Panáček, Aleš [Regional Centre of Advanced Technologies and Materials, Department of Physical Chemistry, Faculty of Science, Palacky University, 17.listopadu 12, CZ 771 46 Olomouc (Czech Republic); Skopalová, Jana [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacky University, 17.listopadu 12, CZ 771 46 Olomouc (Czech Republic); Kvítek, Libor [Regional Centre of Advanced Technologies and Materials, Department of Physical Chemistry, Faculty of Science, Palacky University, 17.listopadu 12, CZ 771 46 Olomouc (Czech Republic); Petrželová, Kamila [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacky University, 17.listopadu 12, CZ 771 46 Olomouc (Czech Republic); National Reference Laboratory for Chemical Elements, Department of Residues in Kroměříž, State Veterinary Institute Olomouc, Hulínská 2286, CZ 767 60 Kroměříž (Czech Republic); and others

    2014-12-01

    This study examined recoveries of silver determination in animal tissues after wet digestion by inductively coupled plasma mass spectrometry. The composition of the mineralization mixture for microwave assisted digestion was optimized and the best recoveries were obtained for mineralization with HNO{sub 3} and addition of HCl promptly after digestion. The optimization was performed on model samples of chicken meat spiked with silver nanoparticles and a solution of ionic silver. Basic calculations of theoretical distribution of Ag among various silver-containing species were implemented and the results showed that most of the silver is in the form of soluble complexes AgCl{sub 2}{sup −} and AgCl{sub 3}{sup 2−} for the optimized composition of the mineralization mixture. Three animal tissue certified reference materials were then analyzed to verify the trueness and precision of the results. - Highlights: • We performed detailed optimization of microwave assisted digestion procedure of animal tissue used prior to Ag determination by ICP-MS. • We provide basic equilibrium calculations to give theoretical explanation of results from optimization of tested mineralization mixtures. • Results from method validation that was done by analysis of several matrix CRMs are presented.

  9. Solid-phase microextraction gas chromatography-mass spectrometry determination of fragrance allergens in baby bathwater.

    Science.gov (United States)

    Lamas, J Pablo; Sanchez-Prado, Lucia; Garcia-Jares, Carmen; Llompart, Maria

    2009-07-01

    A method based on solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been optimized for the determination of fragrance allergens in water samples. This is the first study devoted to this family of cosmetic ingredients performed by SPME. The influence of parameters such as fibre coating, extraction and desorption temperatures, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mixed-level factorial design, which allowed the study of the main effects as well as two-factor interactions. Excluding desorption temperature, the other parameters were, in general, very important for the achievement of high response. The final procedure was based on headspace sampling at 100 degrees C, using polydimethylsiloxane/divinylbenzene fibres. The method showed good linearity and precision for all compounds, with detection limits ranging from 0.001 to 0.3 ng mL(-1). Reliability was demonstrated through the evaluation of the recoveries in different real water samples, including baby bathwater and swimming pool water. The absence of matrix effects allowed the use of external standard calibration to quantify the target compounds in the samples. The proposed procedure was applied to the determination of allergens in several real samples. All the target compounds were found in the samples, and, in some cases, at quite high concentrations. The presence and the levels of these chemicals in baby bathwater should be a matter of concern.

  10. Electrochemical separation and isotopic determination of thallium at the nanogram level by surface ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Arden, J.W.

    1983-01-01

    A rapid low-blank procedure is described for the co-separation of thallium and lead by sequential cathodic and anodic electrodeposition from natural samples, especially complex natural silicates, for subsequent mass spectrometry. A micro anion-exchange procedure is also described for the separation of thallium and lead. Ion currents of 10 - 10 A can be obtained from 1 ng of thallium. The isotopic composition of 1 ng of thallium can be measured on a Faraday detector with a precision of 0.05-0.1%. The total procedural blank is 3 pg. By using stable isotope dilution, 0.2 ng of thallium can be measured with a precision of 0.6% with only a 2% blank correction. This allows the accurate determination of thallium in natural samples down to concentration levels of about 50 pg g - 1 . The detection limit is 50 fg. This procedure has been applied to meteorites and terrestrial rocks. The stable isotope dilution technique is suitable for geochemical, environmental and toxicological studies requiring a highly sensitive, accurate and precise method for the determination of thallium. (Auth.)

  11. Comparison of Mass Transfer Models for Determination of the Intestinal Permeability

    Directory of Open Access Journals (Sweden)

    P Zakeri-Milani

    2008-09-01

    Full Text Available Background and the purpose of the study: In determination of the permeability of the intestinal wall by external perfusion techniques, several models have been proposed. In the present study three models were used for experimental results that differ in their convection and diffusion assumptions. Material and Methods: Permeability coefficients for 13 compounds (metoprolol, propranolol, naproxen, ketoprofen, furosemide, hydrochlorothiazide, cimetidine, ranitidine, atenolol, piroxicam, antipyrine, ibuprofen and carbamazepine with known human intestinal permeability values were determined in anaesthetized rats by different mass transfer models and plotted versus the observed human intestinal permeabilities. Results: The calculated dimensionless wall permeability values were in the range of 0.37 - 4.85, 0.38-6.54 and 0.41-16.59 for complete radial mixing, mixing tank and laminar flow models respectively. The results indicated that all of the models work relatively well for our data despite fundamentally different assumptions. The wall permeabilities were in the order laminar flow > mixing tank > complete radial mixing. Conclusion: Although laminar flow model provides the most direct measure of the intrinsic wall permeability, it has limitations for highly permeable drugs such as ibuprofen. The normal physiological hydrodynamics is more complex and more investigation is required to find out the real hydrodynamics.

  12. [Determination of olive oil content in olive blend oil by headspace gas chromatography-mass spectrometry].

    Science.gov (United States)

    Jiang, Wanfeng; Zhang, Ning; Zhang, Fengyan; Yang, Zhao

    2017-07-08

    A method for the determination of the content of olive oil in olive blend oil by headspace gas chromatography-mass spectrometry (SH-GC/MS) was established. The amount of the sample, the heating temperature, the heating time, the amount of injection, the injection mode and the chromatographic column were optimized. The characteristic compounds of olive oil were found by chemometric method. A sample of 1.0 g was placed in a 20 mL headspace flask, and heated at 180℃ for 2700 s. Then, 1.0 mL headspace gas was taken into the instrument. An HP-88 chromatographic column was used for the separation and the analysis was performed by GC/MS. The results showed that the linear range was 0-100%(olive oil content). The linear correlation coefficient ( r 2 ) was more than 0.995, and the limits of detection were 1.26%-2.13%. The deviations of olive oil contents in the olive blend oil were from -0.65% to 1.02%, with the relative deviations from -1.3% to 6.8% and the relative standard deviations from 1.18% to 4.26% ( n =6). The method is simple, rapid, environment friendly, sensitive and accurate. It is suitable for the determination of the content of olive oil in olive blend oil.

  13. Determination of metals content from wines by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Iordache, Andreea-Maria; Geana, Elisabeta-Irina

    2009-01-01

    Full text: Wine is a widely consumed beverage with thousands of years of tradition. Wine composition strongly determines its quality besides having a great relevance on wine characterization, tipyfication and frauds detection. Wine composition is influenced by many and diverse factors corresponding to the specific production area, such as grape variety, soil and climate, culture, yeast, winemaking practices, transport and storage. Daily consumption of wine in moderate quantities contributes significantly to the requirements of the human organism for essential elements such as Cr, Cu, Zn, Fe, Mn, Co, Ni and Sr. On the other hand, several metals, such as Pb and Cd , are known to be potentially toxic. The objective of this work was to develop a method to determine the metals content in wine samples from Romania. Three samples of difference white wines available in the supermarket was analyzed for identify the presence of: Cr, Cu, Zn, Fe, Mn, Pb, Cd, Co, Ni and Sr by inductively coupled plasma mass spectrometry (ICP-MS). (authors)

  14. Determination of sulfur in steels by isotope dilution mass spectrometry after dissolution with sealed tube

    International Nuclear Information System (INIS)

    Watanabe, Kazuo

    1981-01-01

    The scaled tube dissolution technique was studied for the complete conversion of sulfur in steels to sulfate. Isotope dilution mass spectrometry was used for the determination of sulfur in the sulfate. Sample (0.5 g) was dissolved in nitric acid (7 ml) and hydrochloric acid (3 ml) in a scaled borosilicate glass tube on being heated above 180 0 C overnight. Nitrate ions were removed by repeated evaporation with hydrochloric acid. The residue was dissolved in hydrochloric acid. Sulfate was reduced with a mixture of hydrochloric, hydroiodic and hypophosphorous acids; hydrogen sulfide evolved was absorbed in cadmium acetate solution, then converted to silver sulfide, which was burned to sulfur dioxide in pure oxygen at low pressure, for isotopic analysis. Analytical blank in whole procedure was 0.8 μg of sulfur. This technique was applied to the determination of sulfur in NBS low alloy steels. The principal cause of low values obtained by the open beaker dissolution technique was evaporation losses of sulfur as sulfur dioxide during the dissolution. (author)

  15. Determination of cadmium, lead and zinc in a candidate reference materials using isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Munoz, Luis; Gras, Nuri; Quejido, Alberto; Fernandez, Marta

    2001-01-01

    The growing demands placed on analytical laboratories to ensure the reliability of their results, due to the introduction of systems of quality and to the increasing use of metrology in chemical measurements has led most laboratories to validate their methodologies and to control them statistically. One of the techniques used most often for these purposes is based on the use of reference materials. The proper use of these materials means that laboratory results may be traced to the International System of Units, analytical methodologies can be validated, instruments calibrated and chemical measurements harmonized. One of the biggest challenges in developing reference materials is that of certifying their properties, a process that has been defined as assigning a concentration value that is as close as possible to the true value together with its uncertainty. Organizations that produce reference materials use several options for their certification process, and among these is the use of a primary method. Among the primary methods recognized by the International Office of Weights and Measures is the Isotope Dilution Mass Spectrometry technique. The Chilean Nuclear Energy Commission, through its Reference Materials Program, has prepared a reference material of clam tissue, which has been chemically defined by different analytical methodologies applied in different national and international laboratories. This work describes the methodology developed with the CIEMAT for determining the elements lead, cadmium and zinc in the clam tissue reference material using the primary technique of Isotope Dilution Mass Spectrometry. The calculation is described for obtaining the spike amounts to be added to the sample and the procedure is explained for carrying out the isotopic exchange. The isotopic relationships 204 Pb/ 205 Pb, 111 Cd/ 114 Cd and 66 Zn/ 67 Zn were determined in an atomic emission spectrometer with a plasma source with the following characteristics: plasma

  16. First on-line mass measurements at SHIPTRAP and mass determinations of neutron-rich Fr and Ra isotopes at ISOLTRAP

    CERN Document Server

    Rahaman, Saidu

    SHIPTRAP is an ion trap facility behind the velocity filter SHIP at GSI/Darmstadt. Its aim are precision studies of transuranium nuclides produced in a fusion reaction and separated by SHIP. The current set-up for high-precision mass measurements consists of three main functional parts: (i) a gas cell for stopping the energetic ions from SHIP, (ii) radiofrequency quadrupole structures to cool and to bunch the ions extracted from the gas cell, and (iii) a superconducting magnet with two cylindrical Penning traps at a field strength of 7 T. In this work the Penning trap system has been installed and extensively characterized. The first on-line mass measurements of short-lived nuclides were carried out and the masses of $^{147}$Er and $^{148}$Er could be experimentally determined for the first time. Here a relative mass uncertainty of $\\delta$ m/m of about 1$\\times$ 10$^{-6}$ was achieved. Furthermore the masses of heavy neutron-rich $^{229-232}$Ra and $^{230}$Fr isotopes have been determined with a relative m...

  17. PDF uncertainties in the determination of the W boson mass and of the effective lepton mixing angle at the LHC

    CERN Document Server

    Rojo, Juan

    2013-01-01

    The precision measurement of the W boson mass allows to perform stringent consistency tests of the Standard Model by means of global electroweak fits. The accurate determination of the W boson mass is one of the legacy results of the Tevatron, where the experimental accuracy is such that $M_W$ is now limited by theoretical uncertainties related to the parton distributions of the proton. In this contribution, we show how to quantify the impact of PDF uncertainties in the measurement of $M_W$ at the Tevatron and the LHC by means of a template method, and study both the use of the W transverse mass and the lepton pT kinematical distributions to generate these templates. We also present preliminary results on the quantification of the PDF uncertainties in the determination of the effective lepton mixing angle at the LHC, based on the same template method as for the W mass determination

  18. The Mass Balance of Glacier No. 1 at the Headwaters of the Urumqi River in Relation to Northern Hemisphere Teleconnection Patterns

    Directory of Open Access Journals (Sweden)

    Feifei Yuan

    2016-03-01

    Full Text Available Most small glaciers in the world have significantly decreased their volume during the last century, which has caused water shortage problems. Glacier No. 1, at the headwaters of the Urumqi River, Tianshan, China, has been monitored since 1959 and similarly has experienced significant mass and volume losses over the last few decades. Thus, we examined the trend and potential abrupt changes of the mass balance of Glacier No. 1. Principal component analysis and singular value decomposition were used to find significant relations between the mass balance of Glacier No. 1 and Northern Hemisphere teleconnection patterns using climate indices. It was found that the mass balance of Glacier No. 1 had a significantly decreasing trend corresponding to −14.5 mm/year from 1959 to 2010. A change point was detected in 1997 with 99% confidence level. Two time periods with different mass balances were identified as 1959–1996 and 1997–2010. The mass balance for the first period was −136.4 mm/year and up to −663.9 mm/year for the second period. The mass balance of Glacier No. 1 is positively related to the Scandinavian Pattern (SCA, and negatively related to the East Atlantic Pattern (EA. These relationships are useful in better understanding the interaction between glacier mass balance and climate variability.

  19. Determining the pattern of cementum annuli and relationship to reproduction in male sea otters

    Science.gov (United States)

    Proper, Josh; von Biela, Vanessa R.; Burns, Jennifer M.

    2007-01-01

    Since the early 1990s, the southwestern Alaskan sea otter (Enhydra lutris) population has declined dramatically and the cause has yet to be determined. Population trajectories of large mammals are determined by three factors: survival rate, reproduction rate, and age of first reproduction (AFR). Of these three, AFR should respond first to environmental change. Life history theory predicts that AFR will be older with bottom-up causes (ie, food limitation) and younger when the cause of the decline is top-down (ie, predation), as there is usually abundant resources in this scenario. Traditionally, determining AFR required lethal sampling, which may not always be possible. Work on many mammalian species suggests that the width of annual cementum layers in teeth may decline when breeding begins. If so, examining teeth annuli may provide a nonlethal alternative for determining AFR. Ongoing research has shown this relationship in female sea otters, but male sea otters have not been tested. Sea otter testes and premolar teeth slides were collected by subsistence hunters working with the US Fish and Wildlife Service and the Alaska Sea Otter and Steller Sea Lion Commission from Alaska (1994– 2005). We determined the pattern in cementum annuli thickness for male sea otters across age by measuring annuli at three sites on each of the two slide sections available. We found that cementum annuli layers decreased with age, but found no correlation between cementum annuli and sexual maturity in male sea otters. This lack of correlation may be due to sampling error or different energy expenditures during reproduction for each sex. Since females expend large amounts of energy through gestation and lactation, we hypothesize that the width of female cementum annuli decreases at a much sharper rate when they reach AFR.The southwest Alaskan sea otter population has plummeted up to 90% since the early 1990s and the reason is unknown.1 Declines may be due to a bottom-up source caused by

  20. Mass-produced lonophore-based fluorescent microspheres for trace level determination of lead ions.

    Science.gov (United States)

    Telting-Diaz, Martin; Bakker, Eric

    2002-10-15

    The development and characterization of small, uniform, and mass-produced plasticized PVC-based sensing microspheres in view of rapid trace level analysis of lead ions is reported. Micrometer-sized particles obtained via an automated casting process were rendered selective for lead ions by doping them with highly selective components in a manner analogous to traditional optode sensing films. Single particles that contained the lipophilic ionophore N,N,N',N'-tetradodecyl-3-6-dioxaoctane-1-thio-8-oxodiamide (ETH 5493), the chromoionophore ETH 5418 together with a lipophilized indocarbocyanine derivative as internal reference dye (DiIC18), and lipophilic ion-exchanger sites sodium tetrakis[3,5-bistrifluoromethylphenyl]borate, yielded measurable lead responses at the low nanomolar level in pH buffered solutions. The detection limit for single particles was 3 x 10(-9) M at pH 5.7. The microspheres were fabricated via a reproducible formation of polymer droplets within a flowing aqueous phase followed by collection of spherical particles of approximately 13 microm in size. The particles were immobilized and assayed individually in a microflow cell via fluorescence microscopy. Selectivity patterns found were in agreement with those reported earlier for the lead-selective ligand ETH 5493, and all response functions were fully described by theory. In contrast to optode films that necessitated very long equilibration times and large sample volumes in diluted samples of analyte, particles exhibited extremely enhanced equilibrium response times. Thus, for lead sample concentrations at and above 5 x 10(-8) M, response times were approximately 3 min, whereas at the detection limit, complete equilibrium was recorded after just 15 min, with required sample volumes on the order of 1 mL This new class of microspheres appears to be suitable for rapid and sensitive ion detection at trace levels in environmental and biological applications.

  1. Determination of baryon and baryonic resonance masses from QCD sum rules. Strange baryons

    International Nuclear Information System (INIS)

    Belyaev, V.M.; Ioffe, B.L.

    1982-01-01

    The mass differences in baryonic octet Jsup(P)=1/2sup(+), decuplet Jsup(P)=3/2sup(+) and in octet Jsup(P)=3/2sup(-) are calculated basing on the QCD sum rules. The mass differences are expressed through two QCD parameters: the strange current qUark mass and the value of the quark condensate. At the properly chosen values of these parameters all of the mass differences are in a good agreement with experiment

  2. Concerted evolution of body mass and cell size: similar patterns among species of birds (Galliformes) and mammals (Rodentia)

    Science.gov (United States)

    Dragosz-Kluska, Dominika; Pis, Tomasz; Pawlik, Katarzyna; Kapustka, Filip; Kilarski, Wincenty M.; Kozłowski, Jan

    2018-01-01

    ABSTRACT Cell size plays a role in body size evolution and environmental adaptations. Addressing these roles, we studied body mass and cell size in Galliformes birds and Rodentia mammals, and collected published data on their genome sizes. In birds, we measured erythrocyte nuclei and basal metabolic rates (BMRs). In birds and mammals, larger species consistently evolved larger cells for five cell types (erythrocytes, enterocytes, chondrocytes, skin epithelial cells, and kidney proximal tubule cells) and evolved smaller hepatocytes. We found no evidence that cell size differences originated through genome size changes. We conclude that the organism-wide coordination of cell size changes might be an evolutionarily conservative characteristic, and the convergent evolutionary body size and cell size changes in Galliformes and Rodentia suggest the adaptive significance of cell size. Recent theory predicts that species evolving larger cells waste less energy on tissue maintenance but have reduced capacities to deliver oxygen to mitochondria and metabolize resources. Indeed, birds with larger size of the abovementioned cell types and smaller hepatocytes have evolved lower mass-specific BMRs. We propose that the inconsistent pattern in hepatocytes derives from the efficient delivery system to hepatocytes, combined with their intense involvement in supracellular function and anabolic activity. PMID:29540429

  3. Concerted evolution of body mass and cell size: similar patterns among species of birds (Galliformes and mammals (Rodentia

    Directory of Open Access Journals (Sweden)

    Marcin Czarnoleski

    2018-04-01

    Full Text Available Cell size plays a role in body size evolution and environmental adaptations. Addressing these roles, we studied body mass and cell size in Galliformes birds and Rodentia mammals, and collected published data on their genome sizes. In birds, we measured erythrocyte nuclei and basal metabolic rates (BMRs. In birds and mammals, larger species consistently evolved larger cells for five cell types (erythrocytes, enterocytes, chondrocytes, skin epithelial cells, and kidney proximal tubule cells and evolved smaller hepatocytes. We found no evidence that cell size differences originated through genome size changes. We conclude that the organism-wide coordination of cell size changes might be an evolutionarily conservative characteristic, and the convergent evolutionary body size and cell size changes in Galliformes and Rodentia suggest the adaptive significance of cell size. Recent theory predicts that species evolving larger cells waste less energy on tissue maintenance but have reduced capacities to deliver oxygen to mitochondria and metabolize resources. Indeed, birds with larger size of the abovementioned cell types and smaller hepatocytes have evolved lower mass-specific BMRs. We propose that the inconsistent pattern in hepatocytes derives from the efficient delivery system to hepatocytes, combined with their intense involvement in supracellular function and anabolic activity.

  4. Dietary patterns and lifestyle : Their determinants and associations with chronic disease burden

    NARCIS (Netherlands)

    Fransen, HP

    2016-01-01

    In this thesis we investigated in a Dutch cohort dietary patterns and other lifestyle habits in relation with disease burden. Our aim was to define the healthiest dietary pattern in the Netherlands and provide insight in the lifestyle factors that are associated with this pattern. Quality Adjusted

  5. Isolation and Determination of Antibiotic Resistance Patterns in Nontyphoid Salmonella spp isolated from chicken

    Directory of Open Access Journals (Sweden)

    Seyyedeh Hoorieh Fallah

    2013-01-01

    Full Text Available Background: Salmonellosis is one of the most common food borne diseases in industrial and developing countries. In recent years, an increase in antimicrobial drug resistance, among non-typhoid Salmonella spp has been observed. Objectives: The aim of this study was to isolate and determine antibiotic resistance pattern in non-typhoid Salmonella spp. Materials and Methods: This descriptive study was done on 100 samples of chickens collected from 196 retail markets and was examined for the presence of Salmonella using standard bacteriological procedures and stereotyping kit. Antimicrobial susceptibility testing was performed by disk diffusion methods according to the National Committee for Clinical Laboratory Standards (CLSI. The data were analyzed by using the SPSS software version 18. Result: Forty- four percent of samples were contaminated with Salmonella infection and 56% didn’t have any contamination. The stereotyping results showed that 34 of 44 isolates of Salmonella belonged to Salmonella infantis (79.5 %, one strain (2.3% of group C and 8 strain (18.2% of group D. However, all these strains were sensitive to Cefotaxime and Ciprofloxacin, and 100% were resistant to Nalidixic acid, Tetracyclin and Sterptomycin. The most common resistance pattern (34.1% was towards six antibiotics, and 6.8% of strains were resistant to at least three antibiotics. Conclusion: High levels of resistance to antibiotics that are used commonly for human and poultry can be a warning for our community health and this information must be used to form important strategies for improvement of infection control.

  6. Pattern of access determines influence of junk food diet on cue sensitivity and palatability.

    Science.gov (United States)

    Kosheleff, Alisa R; Araki, Jingwen; Hsueh, Jennifer; Le, Andrew; Quizon, Kevin; Ostlund, Sean B; Maidment, Nigel T; Murphy, Niall P

    2018-04-01

    Like drug addiction, cues associated with palatable foods can trigger food-seeking, even when sated. However, whether susceptibility to the motivating influence of food-related cues is a predisposing factor in overeating or a consequence of poor diet is difficult to determine in humans. Using a rodent model, we explored whether a highly palatable 'junk food' diet impacts responses to reward-paired cues in a Pavlovian-to-instrumental transfer test, using sweetened condensed milk (SCM) as the reward. The hedonic impact of SCM consumption was also assessed by analyzing licking microstructure. To probe the effects of pattern and duration of junk food exposure, we provided rats with either regular chow ad libitum (controls) or chow plus access to junk food for either 2 or 24 h per day for 1, 3, or 6 weeks. We also examined how individual susceptibility to weight gain related to these measures. Rats provided 24 h access to the junk food diet were insensitive to the motivational effects of a SCM-paired cue when tested sated even though their hedonic experience upon reward consumption was similar to controls. In contrast, rats provided restricted, 2 h access to junk food exhibited a cue generalization phenotype under sated conditions, lever-pressing with increased vigor in response to both a SCM-paired cue, and a cue not previously paired with reward. Hedonic response was also significantly higher in these animals relative to controls. These data demonstrate that the pattern of junk food exposure differentially alters the hedonic impact of palatable foods and susceptibility to the motivating influence of cues in the environment to promote food-seeking actions when sated, which may be consequential for understanding overeating and obesity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Morbidity pattern and its sociodemographic determinants among elderly population of Raichur district, Karnataka, India

    Directory of Open Access Journals (Sweden)

    Leyanna Susan George

    2017-01-01

    Full Text Available Context: India is an “aging nation” with 7.7% of its population being above 60 years of age. It has resulted in a rise of both physical and mental health morbidities. Aims: This study aimed to gather information regarding the morbidity pattern and its sociodemographic determinants among the elderly residing in the rural villages of Raichur, to understand the need for geriatric health-care facilities. Settings and Design: This community-based cross-sectional study was carried out in six rural villages of Raichur District, of which 230 elderly were selected randomly. Subjects and Methods: The data were collected using a questionnaire, clinical history, examination, and cross-checking of medical records. Statistical Analysis Used: Data were analyzed using Epi Info version-3.5.3. Results: The prevalence of morbidity was 91.7% with an average of 3/person. Females (58.9% had more morbidities than men (41.1%. The 3 most common morbidities were orthopedic (50.5%, cataract (50.4%, and respiratory (31.3%. 26.6% suffered from gastrointestinal morbidities while 23.9% had dental problems. 20.9% had hypertension with equal prevalence among both sexes. Only 17.4% were diabetics with majority being women. Central nervous system morbidities were 14.2% while 9.6% suffered from hearing loss and varicose veins. 8.2% had genitourinary-urinary morbidities and incontinence (1.7% was common among both sexes. Depression (71.1% and dermatological morbidities (4.7% were prevalent among women. Only 3.5% suffered from cardiac morbidity and 0.4% from cancer. Significant association was found between age and morbidity and also between socioeconomic class and morbidity pattern. Conclusions: Geriatric care should become an integral part of primary health care. Regular screening and Information, Education, and Communication activities need to be provided early in life for ensuring healthy aging.

  8. Triple sorbent thermal desorption/gas chromatography/mass spectrometry determination of vapor phase organic contaminants

    International Nuclear Information System (INIS)

    Ma, C.Y.; Skeen, J.T.; Dindal, A.B.; Higgins, C.E.; Jenkins, R.A.

    1994-05-01

    A thermal desorption/ps chromatography/mass spectrometry (TD/GC/MS) has been evaluated for the determination of volatile organic compounds (VOCS) in vapor phase samples using Carbosieve S-III/Carbotrap/Carotrap C triple sorbent traps (TST) similar to those available from a commercial source. The analysis was carried out with a Hewlett-Packard 5985A or 5995 GC/MS system with a modified injector to adapt an inhouse manufactured short-path desorber for transferring desorbate directly onto a cryofocusing loop for subsequent GC/MS analysis. Vapor phase standards generated from twenty six compounds were used for method validation, including alkanes, alkyl alcohols, alkyl ketones, and alkyl nitrites, a group of representative compounds that have previously been identified in a target airborne matrix. The method was validated based on the satisfactory results in terms of reproducibility, recovery rate, stability, and linearity. A relative, standard deviation of 0.55 to 24.3 % was obtained for the entire TD process (generation of gas phase standards, spiking the standards on and desorbing from TST) over a concentration range of 20 to 500 ng/trap. Linear correlation coefficients for the calibration curves as determined ranged from 0.81 to 0.99 and limits of detection ranged from 3 to 76 ng. For a majority of standards, recoveries of greater than 90% were observed. For three selected standards spiked on TSTS, minimal loss (10 to 22%) was observed after storing the spiked in, a 4 degree C refrigerator for 29 days. The only chromatographable artifact observed was a 5% conversion of isopropanol to acetone. The validated method been successfully applied, to the determination of VOCs collected from various emission sources in a diversified concentration range

  9. Role of parathyroid hormone in determination of fat mass in patients with Vitamin D deficiency

    Directory of Open Access Journals (Sweden)

    Raman K Marwaha

    2017-01-01

    Full Text Available Background: Obesity has become a global epidemic and it is rising is Asia. Vitamin D deficiency (VDD is widely prevalent in the Indian subcontinent. Studies have linked VDD to obesity and shown correlation between parathyroid hormone (PTH, 25-hydroxy Vitamin D (25(OHD, and fat mass (FM. However, studies on the role of PTH among subjects with VDD are lacking. Objective: The objective of this study is to study the role of PTH in the determination of FM in participants with VDD. Subjects: Five hundred and fifty-one adults (m:247, f:304 were included in this study. Materials and Methods: Total and regional (trunk, arm, and leg FM was assessed by dual X-ray absorptometry. Biochemical and hormonal parameters such as calcium, phosphorus, alkaline phosphatase, ionic calcium, 25(OHD, and PTH were also analyzed. Results: The mean age of the study population was 58.8 ± 15.8 years (Male: [63.3 ± 13.1], Female: [55.2 ± 16.9]. FM and body mass index were significantly lower in females with higher levels of serum 25(OHD. Total FM was negatively correlated with serum 25(OHD (r = −0.363, P < 0.0001 and positively correlated with serum PTH (r: 0.262, P < 0.0001 in females only. Females with VDD and secondary hyperparathyroidism had higher FM than those with normal PTH. Conclusions: Females with VDD had higher total and regional FM. However, this correlation was evident only in those with high serum PTH levels, suggesting a potential role of PTH in the accumulation of FM.

  10. Honeybee venom proteome profile of queens and winter bees as determined by a mass spectrometric approach.

    Science.gov (United States)

    Danneels, Ellen L; Van Vaerenbergh, Matthias; Debyser, Griet; Devreese, Bart; de Graaf, Dirk C

    2015-10-30

    Venoms of invertebrates contain an enormous diversity of proteins, peptides, and other classes of substances. Insect venoms are characterized by a large interspecific variation resulting in extended lists of venom compounds. The venom composition of several hymenopterans also shows different intraspecific variation. For instance, venom from different honeybee castes, more specifically queens and workers, shows quantitative and qualitative variation, while the environment, like seasonal changes, also proves to be an important factor. The present study aimed at an in-depth analysis of the intraspecific variation in the honeybee venom proteome. In summer workers, the recent list of venom proteins resulted from merging combinatorial peptide ligand library sample pretreatment and targeted tandem mass spectrometry realized with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS/MS). Now, the same technique was used to determine the venom proteome of queens and winter bees, enabling us to compare it with that of summer bees. In total, 34 putative venom toxins were found, of which two were never described in honeybee venoms before. Venom from winter workers did not contain toxins that were not present in queens or summer workers, while winter worker venom lacked the allergen Api m 12, also known as vitellogenin. Venom from queen bees, on the other hand, was lacking six of the 34 venom toxins compared to worker bees, while it contained two new venom toxins, in particularly serine proteinase stubble and antithrombin-III. Although people are hardly stung by honeybees during winter or by queen bees, these newly identified toxins should be taken into account in the characterization of a putative allergic response against Apis mellifera stings.

  11. Honeybee Venom Proteome Profile of Queens and Winter Bees as Determined by a Mass Spectrometric Approach

    Science.gov (United States)

    Danneels, Ellen L.; Van Vaerenbergh, Matthias; Debyser, Griet; Devreese, Bart; de Graaf, Dirk C.

    2015-01-01

    Venoms of invertebrates contain an enormous diversity of proteins, peptides, and other classes of substances. Insect venoms are characterized by a large interspecific variation resulting in extended lists of venom compounds. The venom composition of several hymenopterans also shows different intraspecific variation. For instance, venom from different honeybee castes, more specifically queens and workers, shows quantitative and qualitative variation, while the environment, like seasonal changes, also proves to be an important factor. The present study aimed at an in-depth analysis of the intraspecific variation in the honeybee venom proteome. In summer workers, the recent list of venom proteins resulted from merging combinatorial peptide ligand library sample pretreatment and targeted tandem mass spectrometry realized with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS/MS). Now, the same technique was used to determine the venom proteome of queens and winter bees, enabling us to compare it with that of summer bees. In total, 34 putative venom toxins were found, of which two were never described in honeybee venoms before. Venom from winter workers did not contain toxins that were not present in queens or summer workers, while winter worker venom lacked the allergen Api m 12, also known as vitellogenin. Venom from queen bees, on the other hand, was lacking six of the 34 venom toxins compared to worker bees, while it contained two new venom toxins, in particularly serine proteinase stubble and antithrombin-III. Although people are hardly stung by honeybees during winter or by queen bees, these newly identified toxins should be taken into account in the characterization of a putative allergic response against Apis mellifera stings. PMID:26529016

  12. NEAR-INFRARED SPECTROSCOPY OF LOW-MASS X-RAY BINARIES: ACCRETION DISK CONTAMINATION AND COMPACT OBJECT MASS DETERMINATION IN V404 Cyg AND Cen X-4

    International Nuclear Information System (INIS)

    Khargharia, Juthika; Froning, Cynthia S.; Robinson, Edward L.

    2010-01-01

    We present near-infrared (NIR) broadband (0.80-2.42 μm) spectroscopy of two low-mass X-ray binaries: V404 Cyg and Cen X-4. One important parameter required in the determination of the mass of the compact objects in these systems is the binary inclination. We can determine the inclination by modeling the ellipsoidal modulations of the Roche-lobe filling donor star, but the contamination of the donor star light from other components of the binary, particularly the accretion disk, must be taken into account. To this end, we determined the donor star contribution to the infrared flux by comparing the spectra of V404 Cyg and Cen X-4 to those of various field K-stars of known spectral type. For V404 Cyg, we determined that the donor star has a spectral type of K3 III. We determined the fractional donor contribution to the NIR flux in the H and K bands as 0.98 ± 0.05 and 0.97 ± 0.09, respectively. We remodeled the H-band light curve from Sanwal et al. after correcting for the donor star contribution to obtain a new value for the binary inclination. From this, we determined the mass of the black hole in V404 Cyg to be M BH = 9.0 +0.2 -0.6 M sun . We performed the same spectral analysis for Cen X-4 and found the spectral type of the donor star to be in the range K5-M1 V. The donor star contribution in Cen X-4 is 0.94 ± 0.14 in the H band while in the K band, the accretion disk can contribute up to 10% of the infrared flux. We remodeled the H-band light curve from Shahbaz et al., again correcting for the fractional contribution of the donor star to obtain the inclination. From this, we determined the mass of the neutron star as M NS = 1.5 +0.1 -0.4 M sun . However, the masses obtained for both systems should be viewed with some caution since contemporaneous light curve and spectral data are required to obtain definitive masses.

  13. A mass spectrometric method to determine activities of enzymes involved in polyamine catabolism

    International Nuclear Information System (INIS)

    Moriya, Shunsuke; Iwasaki, Kaori; Samejima, Keijiro; Takao, Koichi; Kohda, Kohfuku; Hiramatsu, Kyoko; Kawakita, Masao

    2012-01-01

    Highlights: ► Compounds in polyamine catabolic pathway were determined by a column-free ESI-TOF MS. ► N 1 - and N 8 -acetylspermidine were determined by a column-free ESI-MS/MS. ► The method was applied to determine activities of APAO, SMO, and SSAT in the pathway. ► The assay method contained stable isotope-labeled natural substrates. ► It is applicable to biological samples containing natural substrate and product. - Abstract: An analytical method for the determination of three polyamines (putrescine, spermidine, and spermine) and five acetylpolyamines [N 1 -acetylspermidine (N 1 AcSpd), N 8 -acetylspermidine (N 8 AcSpd), N 1 -acetylspermine, N 1 ,N 8 -diacetylspermidine, and N 1 ,N 12 -diacetylspermine] involved in the polyamine catabolic pathway has been developed using a hybrid tandem mass spectrometer. Heptafluorobutyryl (HFB) derivatives of these compounds and respective internal standards labeled with stable isotopes were analyzed simultaneously by TOF MS, based on peak areas appearing at appropriate m/z values. The isomers, N 1 AcSpd and N 8 AcSpd were determined from their fragment ions, the acetylamidopropyl and acetylamidobutyl groups, respectively, using MS/MS with 13 C 2 -N 1 AcSpd and 13 C 2 -N 8 AcSpd which have the 13 C 2 -acetyl group as an internal standard. The TOF MS method was successfully applied to measure the activity of enzymes involved in polyamine catabolic pathways, namely N 1 -acetylpolyamine oxidase (APAO), spermine oxidase (SMO), and spermidine/spermine N 1 -acetyltransferase (SSAT). The following natural substrates and products labeled with stable isotopes considering the application to biological samples were identified; for APAO, [4,9,12- 15 N 3 ]-N 1 -acetylspermine and [1,4,8- 15 N 3 ]spermidine ( 15 N 3 -Spd), respectively; for SMO, [1,4,8,12- 15 N 4 ]spermine and 15 N 3 -Spd, respectively; and for SSAT, 15 N 3 -Spd and [1,4,8- 15 N 3 ]-N 1 -acetylspermidine, respectively.

  14. An efficient algorithmic approach for mass spectrometry-based disulfide connectivity determination using multi-ion analysis

    Directory of Open Access Journals (Sweden)

    Yen Ten-Yang

    2011-02-01

    Full Text Available Abstract Background Determining the disulfide (S-S bond pattern in a protein is often crucial for understanding its structure and function. In recent research, mass spectrometry (MS based analysis has been applied to this problem following protein digestion under both partial reduction and non-reduction conditions. However, this paradigm still awaits solutions to certain algorithmic problems fundamental amongst which is the efficient matching of an exponentially growing set of putative S-S bonded structural alternatives to the large amounts of experimental spectrometric data. Current methods circumvent this challenge primarily through simplifications, such as by assuming only the occurrence of certain ion-types (b-ions and y-ions that predominate in the more popular dissociation methods, such as collision-induced dissociation (CID. Unfortunately, this can adversely impact the quality of results. Method We present an algorithmic approach to this problem that can, with high computational efficiency, analyze multiple ions types (a, b, bo, b*, c, x, y, yo, y*, and z and deal with complex bonding topologies, such as inter/intra bonding involving more than two peptides. The proposed approach combines an approximation algorithm-based search formulation with data driven parameter estimation. This formulation considers only those regions of the search space where the correct solution resides with a high likelihood. Putative disulfide bonds thus obtained are finally combined in a globally consistent pattern to yield the overall disulfide bonding topology of the molecule. Additionally, each bond is associated with a confidence score, which aids in interpretation and assimilation of the results. Results The method was tested on nine different eukaryotic Glycosyltransferases possessing disulfide bonding topologies of varying complexity. Its performance was found to be characterized by high efficiency (in terms of time and the fraction of search space

  15. [Determination of 24 minerals in human milk by inductively coupled plasma mass spectrometry with microwave digestion].

    Science.gov (United States)

    Sun, Zhongqing; Yue, Bing; Yang, Zhenyu; Li, Xiaowei; Wu, Yongning; Yin, Shian

    2013-05-01

    To determine the levels of 24 minerals in human milk by inductively coupled plasma mass spectrometry with microwave digestion. The samples were digested by microwave. The contents of minerals were determined by inductively coupled plasma mass spectrometry. The standard reference minerals of 1849a and 1568a from National Institute of Science and Technology were used for quality control. The accuracy and reproduability for this method were evaluated with mix standards and 1849a and 1568a standard reference materials. The ranges of the levels of sodium, magnesium, phosphorus, potassium, calcium, aluminum, chromium, arsenic, selenium, iron, zinc, manganese, copper, molybdenum, vanadium, cobalt, nickel, gallium, cadmium, silver, strontium, cesium, barium, lead in human milk was 34.97-415.83 mg/kg, 19.00-39.52 mg/kg, 102.13-274.53 mg/kg, 351.19-713.99 mg/kg, 180.08-349.64 mg/kg, 0.06-0.44 mg/kg, 0.9-7.37 microg/kg, 0.92-2.72 microg/kg, 0.20-21.15 microg/kg, 0.10-0.70 mg/kg, 0.56-3.25 mg/kg, 3.00-16.12 micro.g/kg, 62.16-591.69 microg/kg, 0.02-6.91 microg/kg, 5.99-13.70 microg/kg, 0.07-2.11 microg/kg, 0.77-209.26 microg/kg, 0.005-0.28 microg/kg, 0.02-0.23 microg/kg, 0.02-0.71 microg/kg, 36.89-132.26 microg/kg, 0.01-4.72 microg/kg, 0.83-28.16 microg/kg, 2.5-5.3 microg/kg, respectively. The levels of minerals in human milk in present study were consisted with other similar studies. The experiment examined the levels of minerals in human milk satisfactorily. The method has high accuracy and good reproducibility, which could be used for understanding the levels of minerals in human milk.

  16. Determination of long-lived radionuclides at ultratrace level using advanced mass spectrometric techniques

    International Nuclear Information System (INIS)

    Zoriy, M.

    2005-11-01

    Determination of long-lived radionuclides at sub-fg concentration level is a challenging task in analytical chemistry. Inductively coupled plasma mass spectrometry (ICP-MS) with its ability to provide the sensitive and fast multielemental analysis is one of the most suitable method for the measurements of long lived radionuclides in the trace and ultra trace concentration range. In present the Ph.D. study a variety of procedures have been developed permitting the sub fg ml-1 determination of long-lived radionuclides (e.g. U, Th, Pu) as well as 226 Ra (T 1/2 = 1600 y) and 90 Sr (T 1/2 = 28.1 y) in different samples. In order to avoid isobaric interferences, to increase the sensitivity, precision and accuracy of the methods the application of different techniques: pre-concentration of the sample, off-line separation on the crown resin, measurements under cold plasma conditions, using microconcentric nebulizers (e.g DIHEN, DS-5) or the application of LA-ICP-MS for sample introduction have been studied. The limits of detection for different radionuclides was significantly improved in comparison to the ones reported in the literature, and, depending on the method applied, was varied from 10 -15 to 10 -18 g ml -1 concentration range. In addition to the analysis of long lived radionuclides, some other elements, that can present potential interest to the analyzed sample, were measured within the framework of the present study. Laser ablation inductively coupled plasma mass spectrometry (LAICP- MS) was used to produce images of element distribution in 20μm m thin sections of human brain tissue. The sample surface was scanned (raster area ∝80 mm 2 ) with a focused laser beam (wavelength 213 nm, diameter of laser crater 50μm, and laser power density 3x10 9 W cm -2 ) in a cooled laser ablation chamber developed for these measurements. Cross sections of human brain samples - hippocampus as well as brain tissues infected and non-infected with Glioblastoma Multiforme (tumor

  17. Food contaminant analysis at ultra-high mass resolution: application of hybrid linear ion trap - orbitrap mass spectrometry for the determination of the polyether toxins, azaspiracids, in shellfish.

    LENUS (Irish Health Repository)

    2010-10-30

    The biotoxins, azaspiracids (AZAs), from marine phytoplankton accumulate in shellfish and affect human health by causing severe gastrointestinal disturbance, diarrhea, nausea and vomiting. Specific and sensitive methods have been developed and validated for the determination of the most commonly occurring azaspiracid analogs. An LTQ Orbitrap mass spectrometer is a hybrid instrument that combines linear ion trap (LIT) mass spectrometry (MS) with high-resolution Fourier transform (FT) MS and this was exploited to perform simultaneous ultra-high-resolution full-scan MS analysis and collision-induced dissociation (CID) tandem mass spectrometry (MS\\/MS). Using the highest mass resolution setting (100,000 FWHM) in full-scan mode, the methodology was validated for the determination of six AZAs in mussel (Mytilus galloprovincialis) tissue extracts. Ultra-high mass resolution, together with a narrow mass tolerance window of ±2 mDa, dramatically improved detection sensitivity. In addition to employing chromatographic resolution to distinguish between the isomeric azaspiracid analogs, AZA1\\/AZA6 and AZA4\\/AZA5, higher energy collisionally induced dissociation (HCD) fragmentation on selected precursor ions were performed in parallel with full-scan FTMS. Using HCD MS\\/MS, most precursor and product ion masses were determined within 1 ppm of the theoretical m\\/z values throughout the mass spectral range and this enhanced the reliability of analyte identity.For the analysis of mussels (M. galloprovincialis), the method limit of quantitation (LOQ) was 0.010 µg\\/g using full-scan FTMS and this was comparable with the LOQ (0.007 µg\\/g) using CID MS\\/MS. The repeatability data were; intra-day RSD% (1.8-4.4%; n = 6) and inter-day RSD% (4.7-8.6%; n = 3). Application of these methods to the analysis of mussels (M. edulis) that were naturally contaminated with azaspiracids, using high-resolution full-scan Orbitrap MS and low-resolution CID MS\\/MS, produced

  18. Online liquid chromatography-tandem mass spectrometry cyanide determination in blood.

    Science.gov (United States)

    Lacroix, C; Saussereau, E; Boulanger, F; Goullé, J P

    2011-04-01

    An original liquid chromatography-tandem mass spectrometry (LC-MS-MS) method coupled to online extraction has been developed for cyanide determination in blood. A method involving fluorimetric detection after naphthalene-2,3-dicarboxyaldehyde (NDA) complexation by taurine in the presence of cyanide was previously described. Its performance was limited because of the absence of an internal standard (IS). Using cyanide isotope (13)C(15)N as IS allowed quantification in MS-MS. After the addition of (13)C(15)N, 25 μL of blood were diluted in water and deproteinized with methanol. Following derivatization with NDA and taurine for 10 min at 4°C, 100 μL was injected into the online LC-MS-MS system. An Oasis HLB was used as an extraction column, and a C18 Atlantis was the analytical column. The chromatographic cycle was performed with an ammonium formate (20 mM, pH 2.8) (solvent A) and acetonitrile/solvent A (90:10, v/v) gradient in 6 min. Detection was performed in negative electrospray ionization mode (ESI(-)) with a Quattro Micro. For quantification, transitions of derivatives formed with CN and (13)C(15)N were monitored, respectively, as follows: 299.3/191.3 and 301.3/193.3. The procedure was fully validated, linear from 26 to 2600 ng/mL with limit of detection of 10 ng/mL. This method, using a small blood sample, is not only simple, but also time saving. The specificity and sensitivity of LC-MS-MS coupled to online extraction and using (13)C(15)N as the IS make this method very suitable for cyanide determination in blood and could be useful in forensic toxicology.

  19. Stability of ingested methylcellulose in the rat determined by polymer molar mass measurements by light scattering.

    Science.gov (United States)

    Yokoyama, Wallace H; Knuckles, Benny E; Davis, Paul A; Daggy, Bruce P

    2002-12-18

    Methylcellulose (MC) is ingested by humans in food and pharmaceutical formulations. The functional properties of MC like those of other linear polymers depend primarily on polymer length or molar mass for largely linear polymers. Although many studies in animals and humans have shown complete excretion of MC, in vitro human fecal fermentation studies indicate that MC can be degraded and presumably lose some of its functionality. In this study, MC polymer distribution in the feces from rats fed a diet containing 8% methylcellulose were compared to the fed MC. The water-soluble polymers in the feces were separated by a size exclusion chromatography (SEC) and the polymer distributions determined by multiple angle laser light scattering (MALLS). Detection of the fluorescent MC-calcofluor complex was used to confirm the identity of the eluting MC peak. All dietary MC was recovered in the feces. There is a small shift (P polymer distribution of MC extracted from the feces to 2.71 +/- 0.15 x 10(5) g/mol from 3.15 +/- 0.02 x 10(5) g/mol in the standard. There is also an increase in the polydispersity from 1.21 in the standard to 1.8 in the fecal extract. The distribution of the substituted methoxylated glucose monomers by gas chromatography also confirms the stability of MC fed to rats. The amount of actual hydrolysis is estimated to be about 0.1 glycosidic linkage/molecule. MC is not easily determined by standard dietary fiber methods, and SEC with MALLS and/or fluorescence may be a useful alternative.

  20. Diurnal pattern of the drying front in desert and its application for determining the effective infiltration

    Directory of Open Access Journals (Sweden)

    Y. Zeng

    2009-06-01

    Full Text Available Located in western Inner Mongolia, the Badain Jaran Desert is the second largest desert in China and consists of a regular series of stable megadunes, among which over 70 permanent lakes exist. The unexpected lakes in desert attracted research interests on exploring the hydrological process under this particular landscape; however, a very few literatures exist on the diurnal and spatial variation of the drying front in this area, which is the main issue in the desert hydrological process to characterize the movement of water in soil. In order to understand the drying front in the Badain Jaran Desert, a field campaign was conducted by the observations of soil physical parameters and micrometeorological parameters. With the field data, the performance of a vadose zone soil water balance model, the HYDRUS, was verified and calibrated. Then, the HYDRUS was used to produce the spatial and temporal information of coupled water, water vapour and heat transport in sand to characterize the variation pattern of the drying front before, during and after the rainfall. Finally, the deepest drying front was applied to determine the effective infiltration, which is defined as the amount of soil water captured by the sand beneath the deepest drying front by infiltrating water of an incident rainfall event.

  1. Determining coding CpG islands by identifying regions significant for pattern statistics on Markov chains.

    Science.gov (United States)

    Singer, Meromit; Engström, Alexander; Schönhuth, Alexander; Pachter, Lior

    2011-09-23

    Recent experimental and computational work confirms that CpGs can be unmethylated inside coding exons, thereby showing that codons may be subjected to both genomic and epigenomic constraint. It is therefore of interest to identify coding CpG islands (CCGIs) that are regions inside exons enriched for CpGs. The difficulty in identifying such islands is that coding exons exhibit sequence biases determined by codon usage and constraints that must be taken into account. We present a method for finding CCGIs that showcases a novel approach we have developed for identifying regions of interest that are significant (with respect to a Markov chain) for the counts of any pattern. Our method begins with the exact computation of tail probabilities for the number of CpGs in all regions contained in coding exons, and then applies a greedy algorithm for selecting islands from among the regions. We show that the greedy algorithm provably optimizes a biologically motivated criterion for selecting islands while controlling the false discovery rate. We applied this approach to the human genome (hg18) and annotated CpG islands in coding exons. The statistical criterion we apply to evaluating islands reduces the number of false positives in existing annotations, while our approach to defining islands reveals significant numbers of undiscovered CCGIs in coding exons. Many of these appear to be examples of functional epigenetic specialization in coding exons.

  2. An experimental comparison of three wire beam electrode based methods for determining corrosion rates and patterns

    International Nuclear Information System (INIS)

    Tan, Y.-J.

    2005-01-01

    Laboratory experiments have been carried out to examine the advantages and limitations of three wire beam electrode (WBE) based techniques, including the noise resistance R n -WBE method, the overpotential-galvanic current method, and the galvanic current method, in determining corrosion rates and patterns. These techniques have been applied simultaneously to several selected corrosion systems of different characteristics. It has been found that the R n -WBE method has advantages over other WBE based methods when applying to WBE surfaces under uniform corrosion. However, the R n -WBE method has been found to be unsuitable for low noise level corrosion systems. It has also been found that both R n -WBE and overpotential-galvanic current methods are similarly applicable to WBE surfaces under nonuniform corrosion. However, the galvanic current method has been found to be suitable only for WBE surfaces under highly localised corrosion. Some related issues regarding R n calculation such as trend removal and its effects on corrosion mapping have also been discussed

  3. Mass spectrometric determination of burnup of thorium-uranium dioxide fuel

    Energy Technology Data Exchange (ETDEWEB)

    Green, L.W.; Knight, C.H.; Longhurst, T.H.; Cassidy, R.M

    1984-07-01

    The isotopes {sup 148}Nd and {sup 145+146}Nd were investigated for use as fission monitors. A two-column anion-exchange procedure was used to separate these and U and Th from the fuel matrix, and the purified fractions were analyzed by thermal ionization mass spectrometry. Relative standard deviations of Nd, U, and Th determinations by isotope dilution were {approx}0.7%. A computer-generated simulation of the irradiation was used to estimate the effective fission yields for {sup 148}Nd and {sup 145+146}Nd. Burnup results with {sup 145+146}Nd as the fission monitor showed excellent agreement with results obtained by a high-performance liquid chromatographic method that used {sup 139}La as the fission monitor; the average difference between the two methods was 0.02%. The {sup 148}Nd results were biased high by up to 4%; this was attributed to a {sup 147}Nd neutron capture effect. Results obtained with the initial heavy element content estimated from the weight and initial composition of the fuel, instead of from analyses for the actinides, showed excellent agreement (average difference = 0.2 %) with the conventional method. (author)

  4. Mass spectrometric determination of burnup of thorium-uranium dioxide fuel

    International Nuclear Information System (INIS)

    Green, L.W.; Knight, C.H.; Longhurst, T.H.; Cassidy, R.M.

    1984-01-01

    The isotopes 148 Nd and 145+146 Nd were investigated for use as fission monitors. A two-column anion-exchange procedure was used to separate these and U and Th from the fuel matrix, and the purified fractions were analyzed by thermal ionization mass spectrometry. Relative standard deviations of Nd, U, and Th determinations by isotope dilution were ∼0.7%. A computer-generated simulation of the irradiation was used to estimate the effective fission yields for 148 Nd and 145+146 Nd. Burnup results with 145+146 Nd as the fission monitor showed excellent agreement with results obtained by a high-performance liquid chromatographic method that used 139 La as the fission monitor; the average difference between the two methods was 0.02%. The 148 Nd results were biased high by up to 4%; this was attributed to a 147 Nd neutron capture effect. Results obtained with the initial heavy element content estimated from the weight and initial composition of the fuel, instead of from analyses for the actinides, showed excellent agreement (average difference = 0.2 %) with the conventional method. (author)

  5. [Determination of arsenic speciation in Scomberomorus niphonius by capillary electrophoresis-inductively coupled plasma mass spectrometry].

    Science.gov (United States)

    Chen, Fa-rong; Zheng, Li; Wang, Zhi-Guang; Sun, Jie; Han, Li-Hui; Wang, Xiao-ru

    2014-06-01

    A method for the detection of arsenocholine (AsC), arsenobetaine (AsB), As(III), dimethylarsinic (DMA), monomethylarsonic (MMA) and As (V) by capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) was established. The results showed that the six species of arsenic were separated within 20 min under the optimized conditions. Good linearities of 6 arsenic species were observed in the range from 2 to 50 μg x L(-1) with the linear correlation greater than 0.996, the detection limits were 0.10-1.08 μg x L(-1) and the RSDs (n = 5) of the peak areas were smaller than 7%. The method was successfully adopted to the determination of the species in Scomberomorus niphonius. The recoveries were between 93% and 98%, and we found the arsenobetaine (AsB) was the main species in the sample. The method was suitable for the analysis of other biological samples with the advantages of good stability, less sample consumption, short analysis time and convenience.

  6. Mass-fragmentographic determination of 25-hydroxy-vitamin D3 using deuterium labeled internal standard

    International Nuclear Information System (INIS)

    Bjorkhem, I.; Holmberg, I.

    1975-01-01

    25-[26- 2 H 3 ] Hydroxy-vitamin D 3 has been synthesized according to the following route: 3β-acetoxy-27-nor-cholest-5-en-25-one → 3β-acetoxy-27-nor-cholesta-5,7-dien-25-one → [26- 2 H 3 ] cholesta-5,7-diene-3β,25-diol → 25-[26- 2 H 3 ] hydroxy-vitamin D 3 . A fixed amount of 25-[26- 2 H 3 ] hydroxy-vitamin D 3 , usually 250 ng, is added to a fixed amount of serum, usually 2.5 ml, and the mixture is extracted with a chloroform-methanol mixture. The extract is chromatographed on a Sephadex LH-20 column together with a trace amount of 25-[26- 3 H] hydroxy-vitamin D 3 . The chromatographic fraction corresponding to 25-hydroxy-vitamin D 3 is collected and the amount of unlabeled 25-hydroxy-vitamin D 3 is determined from the ratio between the mass fragmentographic recording of m/e 131 (base peak of unlabeled 25-hydroxy-vitamin D 3 ) and m/e 134 (base peak of 25-[26- 2 H 3 ] hydroxy-vitamin D 3 ). The relative standard deviation of the method was about 5%. The mean value for 25-hydroxy-vitamin D 3 obtained from 23 different serum samples from healthy Swedish men and women was 27 ng/ml with a standard deviation of 10 ng/ml

  7. Determination of levofloxacin in human serum using liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Samiksha Ghimire

    2018-01-01

    Full Text Available A rapid liquid chromatography tandem-mass spectrometry method was developed for the determination of levofloxacin and its metabolite (desmethyl-levofloxacin in human serum. Sample preparation was done using protein precipitation technique. Our method had a run time of 2.5 min and retention times of 1.6 min for all analytes. The standard curves were linear within the concentration range of 0.10 to 5.00 mg/L for levofloxacin and 0.10 to 4.99 mg/L for desmethyl- levofloxacin; a correlation coefficient (R2 of 0.999 and 0.998 respectively. The lower limit of quantification for both analytes was 0.10 mg/L. Within-day precision ranged from 1.4% and 2.4% for levofloxacin, 1.5% to 5% for desmethyl-levofloxacin and between-day precision ranged from 3.6% to 4.1% for levofloxacin and 0.0% to 3.3% for desmethyl-levofloxacin; whereas, accuracy ranged from 0.1% to 12.7% for levofloxacin and 0.2% to 15.6% for desmethyl-levofloxacin. This method could be a useful asset for routine therapeutic drug monitoring of levofloxacin in multi-drug resistant tuberculosis patients.

  8. Liquid to liquid extraction and liquid chromatography-tandem mass spectrometry determination of hainanmycin in feed.

    Science.gov (United States)

    Wang, Ze Ping; Shen, Jian Zhong; Linhardt, Robert J; Jiang, Hui; Cheng, Lin Li

    2017-03-01

    Hainanmycin is a new veterinary polyether antibiotic and has few sensitive analytical method in present days. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) relying on multiple reaction monitoring (MRM) detection was developed for analysis of hainanmycin in animal feed. Feed samples were extracted with ethyl acetate and purified by two steps of liquid-liquid extraction (LLE) to get rid of water solvable matrix and lipids one by one. The final simple was analyzed by LC-MS/MS. The LC mobile phase was composed of 0.1% aqueous formic acid and 0.1% formic acidified acetonitrile by gradient elution. Average recoveries ranged from 74.22% to 87.85%, as determined by spiking with 2.0 (LOQ) ∼2500μgkg -1 of hainanmycin. The inter-day and intra-day coefficient of variation was 9.21% to 11.77% and 7.67% to 13.49%, respectively. The limit of detection (LOD) and the limit of quantitation (LOQ) were 0.36μgkg -1 and 2.0μgkg -1 , respectively. Copyright © 2016. Published by Elsevier B.V.

  9. Determination of flomoxef in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Kravtsova, Oxana Yu; Paramonov, Sergey A; Vasilevich, Natalya I; Kazyulkin, Denis N; Vlasova, Ekaterina; Engsig, Michael

    2013-12-01

    A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high-performance liquid chromatography-tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative-ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μM, 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10-5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra- and inter-day precisions were flomoxef revealed that it could be successfully analyzed at 4 ºС over 24 h, but it was unstable in solutions at room temperature during short-term storage (4 h) and several freeze-thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Review of clinically accessible methods to determine lean body mass for normalization of standardized uptake values

    International Nuclear Information System (INIS)

    DEVRIESE, Joke; POTTEL, Hans; BEELS, Laurence; MAES, Alex; VAN DE WIELE, Christophe; GHEYSENS, Olivier

    2016-01-01

    With the routine use of 2-deoxy-2-[ 18 F]-fluoro-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) scans, metabolic activity of tumors can be quantitatively assessed through calculation of SUVs. One possible normalization parameter for the standardized uptake value (SUV) is lean body mass (LBM), which is generally calculated through predictive equations based on height and body weight. (Semi-)direct measurements of LBM could provide more accurate results in cancer populations than predictive equations based on healthy populations. In this context, four methods to determine LBM are reviewed: bioelectrical impedance analysis, dual-energy X-ray absorptiometry. CT, and magnetic resonance imaging. These methods were selected based on clinical accessibility and are compared in terms of methodology, precision and accuracy. By assessing each method’s specific advantages and limitations, a well-considered choice of method can hopefully lead to more accurate SUVLBM values, hence more accurate quantitative assessment of 18F-FDG PET images.

  11. Sulfur isotope in nature. Determination of sulfur isotope ratios in coal and petroleum by mass spectrometry

    International Nuclear Information System (INIS)

    Derda, M.

    1999-01-01

    Elementary sulfur or in chemical compounds is one of the elements widespread in the earth's crust and biosphere. Its participation in earth's crust amounts to 0.26 % by weight. Measurement of isotope composition of natural samples can deliver many information about origin, creation and transformation ranges of rocks and minerals. Sulfur isotope ratio contained in minerals is variable and for this reason investigation of isotope sulfur composition can deliver useful information about the geochemistry of each component. Therefore in the investigated sample it is necessary to determine not only the content of sulfur but also the isotope composition of each component. Differentiation of contents of sulfur-34 in natural sulfur compounds can reach up to 110 per mile. So large divergences can be explained by a kinetic effect or by bacterial reduction of sulphates. In this report a wide review of the results of investigations of isotope sulfur compositions in coal and petroleum are presented as well as the methods for the preparation of samples for mass spectrometry analysis are proposed. (author)

  12. Liquid chromatography/mass spectrometric determination of patulin in apple juice using atmospheric pressure photoionization.

    Science.gov (United States)

    Takino, Masahiko; Daishima, Shigeki; Nakahara, Taketoshi

    2003-01-01

    This paper describes a comparison between atmospheric pressure chemical ionization (APCI) and the recently introduced atmospheric pressure photoionization (APPI) technique for the liquid chromatography/mass spectrometric (LC/MS) determination of patulin in clear apple juice. A column switching technique for on-line extraction of clear apple juice was developed. The parameters investigated for the optimization of APPI were the ion source parameters fragmentor voltage, capillary voltage, and vaporizer temperature, and also mobile phase composition and flow rate. Furthermore, chemical noise and signal suppression of analyte signals due to sample matrix interference were investigated for both APCI and APPI. The results indicated that APPI provides lower chemical noise and signal suppression in comparison with APCI. The linear range for patulin in apple juice (correlation coefficient >0.999) was 0.2-100 ng mL(-1). Mean recoveries of patulin in three apple juices ranged from 94.5 to 103.2%, and the limit of detection (S/N = 3), repeatability and reproducibility were 1.03-1.50 ng mL(-1), 3.9-5.1% and 7.3-8.2%, respectively. The total analysis time was 10.0 min. Copyright 2003 John Wiley & Sons, Ltd.

  13. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  14. Radiochemical determination of zirconium by inductively coupled plasma mass spectrometry (ICPMS)

    International Nuclear Information System (INIS)

    Oliveira, Thiago C.; Oliveira, Arno Heeren de

    2013-01-01

    The zirconium isotope 93 Zr is a long-lived pure β-particle-emitting radionuclide thus occurring as one of the radionuclides found in nuclear reactors. It's produced from 235 U fission and from 92 Zr neutron activation. Due to its long half-life, 93 Zr is one of the interest radionuclides for assessment studies performance of waste storage or disposal. Measurement of 93 Zr is difficult owing to its trace level concentration and its low activity in nuclear wastes and further because its certified standards are not frequently available. The aim of this work was to apply a selective radiochemical separation methodology for 93 Zr determination in nuclear waste and analyze it by Inductively Coupled Plasma Mass Spectrometry (ICPMS). To set up the zirconium radiochemical separation procedure, a zirconium tracer solution was used in order to follow the zirconium behavior during the radiochemical separation. A tracer solution containing the main interferences, Ba, Co, Eu, Fe, Mn, Nb, Ni, Sr, and Y was used in order to verify the decontamination factor during separation process. The limit of detection of 0,039 ppb was obtained for zirconium standard solutions by ICPMS. Then, the protocol will be applied to low level waste (LLW) and intermediate level waste (ILW) from nuclear power plants. (author)

  15. Activity determination in the alumina-dysprosia system by Knudsen effusion mass spectrometry

    International Nuclear Information System (INIS)

    Motalov, V.B.; Butman, M.F.; Kudin, L.S.; Markus, T.

    2011-01-01

    Highlights: → Vaporization of Al-Dy-O mixtures has been investigated by KEMS. → The problem of attainment of thermodynamic equilibrium has been described. → The activities of Al 2 O 3 and Dy 2 O 3 have been measured at T = 2130 K. → The Gibbs energies and enthalpies of compound formation have been determined. - Abstract: The vaporization of Al-Dy-O mixtures has been investigated by the Knudsen effusion mass spectrometry technique. The saturated vapor has been found to consist of the atoms Al, O and the molecules AlO, Al 2 O, DyO. At the initial stage the vaporization of Dy 2 O 3 and Al 2 O 3 -Dy 2 O 3 mixtures was found to be incongruent and accompanied by some loss of oxygen. An attainment of congruently vaporizing composition and equilibrium state takes quite a long time. The activities of binary oxides have been measured at T = 2130 K. The Gibbs energies and enthalpies have been derived for formation of the compounds Dy 4 Al 2 O 9 , DyAlO 3 and Dy 3 Al 5 O 12 from sesquioxides.

  16. Levels of Essential Elements in Different Medicinal Plants Determined by Using Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Eid I. Brima

    2018-01-01

    Full Text Available The objective of this study was to investigate the content of essential elements in medicinal plants in the Kingdom of Saudi Arabia (KSA. Five different medical plants (mahareeb (Cymbopogon schoenanthus, sheeh (Artemisia vulgaris, harjal (Cynanchum argel delile, nabipoot (Equisetum arvense, and cafmariam (Vitex agnus-castus were collected from Madina city in the KSA. Five elements Fe, Mn, Zn, Cu, and Se were determined by using inductively coupled plasma mass spectrometry (ICP-MS. Fe levels were the highest and Se levels were the lowest in all plants. The range levels of all elements in all plants were as follows: Fe 193.4–1757.9, Mn 23.6–143.7, Zn 15.4–32.7, Se 0.13–0.92, and Cu 11.3–21.8 µg/g. Intakes of essential elements from the medical plants in infusion were calculated: Fe 4.6–13.4, Mn 6.7–123.2, Zn 7.0–42.7, Se 0.14–1.5, and Cu 1.5–5.0 µg/dose. The calculated intakes of essential elements for all plants did not exceed the daily intake set by the World Health Organization (WHO and European Food Safety Authority (EFSA. These medicinal plants may be useful sources of essential elements, which are vital for health.

  17. Determination of melatonin and its isomer in foods by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Kocadağlı, Tolgahan; Yılmaz, Cemile; Gökmen, Vural

    2014-06-15

    This study aimed to develop a reliable analytical method for the determination of melatonin and its isomers in various food products. The method entails ethanol extraction of solid samples (or dilution of liquid samples) prior to liquid chromatography coupled to triple quadruple mass spectrometry (LC-MS/MS) analysis of target analytes. The method was in-house validated and successfully applied to various food matrices. Recovery of melatonin from different matrices were found to be 86.0 ± 3.6%, 76.9 ± 5.4%, 98.6 ± 6.4%, and 67.0 ± 4.5% for beer, walnut, tomato and sour cherry samples, respectively. No melatonin could be detected in black and green tea, sour cherry, sour cherry concentrate, kefir (a fermented milk drink) and red wine while the highest amount of melatonin (341.7 ± 29.3 pg/g) was detected in crumb. The highest amounts of melatonin isomer were detected in yeast-fermented foods such as 170.7 ± 29.9 ng/ml in red wine, 14.3 ± 0.48 ng/ml in beer, and 15.7 ± 1.4 ng/g in bread crumb. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Do people's goals for mass participation sporting events matter? A self-determination theory perspective.

    Science.gov (United States)

    Coleman, S J; Sebire, S J

    2017-12-01

    Non-elite mass participation sports events (MPSEs) may hold potential as a physical activity promotion tool. Research into why people participate in these events and what goals they are pursuing is lacking. Grounded in self-determination theory, this study examined the associations between MPSE participants' goals, event experiences and physical activity. A prospective cohort study was conducted; pre-event, participants reported their goals for the event. Four weeks post-event, participants reported their motivation for exercise, perceptions of their event achievement and moderate-to-vigorous intensity physical activity (MVPA). Bivariate correlations and path analysis were performed on data from 114 adults. Intrinsic goals (e.g. health, skill and social affiliation) for the event were positively associated with perceptions of event achievement, whereas extrinsic goals (e.g. appearance or social recognition) were not. Event achievement was positively associated with post-event autonomous motivation, which in turn was positively associated with MVPA. Pursuing intrinsic but not extrinsic goals for MPSEs is associated with greater perceptions of event achievement, which in turn is associated with post-event autonomous motivation and MVPA. © The Author 2016. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  19. Pseudo-automatic Determination of Coronal Mass Ejections’ Kinematics in 3D

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Carlos Roberto; Dal Lago, Alisson; Echer, Ezequiel; Souza de Mendonça, Rafael Rodrigues [National Institute for Space Research—INPE, Av. dos Astronautas, 1758, São José dos Campos, SP, 12227-010 (Brazil); Stenborg, Guillermo, E-mail: carlos.braga@inpe.br [Space Science Division, U.S. Naval Research Laboratory, 4555 Overlook Ave. SW Washington, DC 20375 (United States)

    2017-06-20

    Coronal mass ejection (CME) events are among the main drivers of geomagnetic disturbances, and hence play a central role in the Sun–Earth system. Their monitoring and, in particular, the determination of their speed and direction of propagation are key issues for the forecasting of space weather near to Earth. We have implemented a method to track CME events in three dimensions by combining triangulation and tie-pointing analysis with a supervised computer vision algorithm. This novel approach does not rely on any geometric constraint, and eliminates the need for visual identification of the CME boundaries. We applied our method to 17 CME events observed simultaneously by the twin Solar Terrestrial Relations Observatory ( STEREO ) COR2 coronagraph imagers from 2008 December to 2011 November in order to obtain their 3D kinematical characterization (i.e., the velocity vector) along with their morphological properties. About ten of these events have already been analyzed using other methodologies. In these cases, we carried out a thorough comparison with our results and found that, in spite of the different nature and spatial coverage range of the other methods with respect to CORSET3D, the majority of the results agree. We found, however, that three events exhibited discrepancies in the magnitude of the velocity vector, four in the longitudinal direction of propagation, and in only one case was there a discrepancy in latitude. The discrepancies appeared in those cases where quasi-simultaneous, quasi-co-located events were observed in the coronagraphs’ fields of view.

  20. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil.