WorldWideScience

Sample records for patients underwent robotic

  1. Transoral robotic-assisted laryngeal cleft repair in the pediatric patient.

    Science.gov (United States)

    Leonardis, Rachel L; Duvvuri, Umamaheswar; Mehta, Deepak

    2014-09-01

    To assess the feasibility of performing robotic-assisted laryngeal cleft repair in the pediatric population. Retrospective chart review at a tertiary academic children's hospital. All patients underwent transoral robotic-assisted laryngeal cleft repair from March 2011 to June 2013. Demographics, robotic docking time, operative time, and postoperative course and swallowing function were collected and analyzed. Five children, three male and two female, underwent successful transoral robotic-assisted laryngeal cleft repair for closure of a type I laryngeal cleft. Mean age at time of surgery was 21.6 months (standard deviation 6.1 months; range, 15-29 months). From case 1 to case 5, robotic docking time (18-10 minutes), robotic operative time (102-36 minutes), and total operating room time (173-105 minutes) decreased. There were no complications with time until extubation (range, 2-3 days), length of intensive care unit stay (range, 3-4 days), and total hospital stay (range, 3-5 days) within acceptable range following laryngeal cleft repair. Modified barium swallow (two patients) or fiberoptic endoscopic evaluation of swallowing (three patients) was performed postoperatively, with all patients showing complete resolution of penetration and aspiration. In addition, all patients experienced subjective resolution of dysphagia and/or choking with feeds postoperatively. Transoral robotic-assisted laryngeal cleft repair may offer specific advantages over a traditional endoscopic approach. In our experience, the procedure was well tolerated and associated with definitive surgical cure in all patients. The scope of robotic technology continually expands and should be considered a feasible tool at an institution-based level. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  2. A Comparison of Robotic Versus Laparoscopic Adrenalectomy in Patients With Primary Hyperaldosteronism.

    Science.gov (United States)

    Colvin, Jennifer; Krishnamurthy, Vikram; Jin, Judy; Shin, Joyce; Siperstein, Allan; Berber, Eren

    2017-10-01

    Over the last decade, robotic approaches have been described for removing adrenal tumors. Although there are reports comparing robotic and laparoscopic techniques in general, there are limited data on outcomes in patients with primary hyperaldosteronism (PHA). The aim of this study is to compare the safety and efficacy of robotic adrenalectomy (RA) versus laparoscopic adrenalectomy (LA) for PHA. The records of 20 patients who underwent RA for PHA were compared with 16 patients who underwent LA between 2000 and 2014. Data were retrospectively reviewed from a prospectively maintained, IRB-approved adrenal database. Statistical analysis was performed using t test and the Fisher exact analysis. Continuous variables are reported as mean±SEM. Demographic and clinical parameters were similar between the groups. There were no conversions to open in either group. Estimated blood loss, length of stay, and complication rates were comparable. Operative time was shorter in the robotic versus laparoscopic group (130±8.94 vs. 159±11.1 min, P=0.0487). In follow-up, the improvement in patients' blood pressure after adrenalectomy, as assessed by the reduction in the number of antihypertensive medications, was similar between the 2 groups. However, 1 patient in the RA and 1 patient in the LA group were not cured, as determined by postoperative aldosterone:renin levels. The biochemical cure rate between the groups was similar (P=0.529). To our knowledge, this is the first study comparing robotic versus laparoscopic resection of PHA. Our results show that the robotic approach was similar to laparoscopic regarding safety and efficacy. Operative time was shorter with the robotic approach, which could be related to more efficient dissection with wristed instrumentation.

  3. Tailor-made rehabilitation approach using multiple types of hybrid assistive limb robots for acute stroke patients: A pilot study.

    Science.gov (United States)

    Fukuda, Hiroyuki; Morishita, Takashi; Ogata, Toshiyasu; Saita, Kazuya; Hyakutake, Koichi; Watanabe, Junko; Shiota, Etsuji; Inoue, Tooru

    2016-01-01

    This article investigated the feasibility of a tailor-made neurorehabilitation approach using multiple types of hybrid assistive limb (HAL) robots for acute stroke patients. We investigated the clinical outcomes of patients who underwent rehabilitation using the HAL robots. The Brunnstrom stage, Barthel index (BI), and functional independence measure (FIM) were evaluated at baseline and when patients were transferred to a rehabilitation facility. Scores were compared between the multiple-robot rehabilitation and single-robot rehabilitation groups. Nine hemiplegic acute stroke patients (five men and four women; mean age 59.4 ± 12.5 years; four hemorrhagic stroke and five ischemic stroke) underwent rehabilitation using multiple types of HAL robots for 19.4 ± 12.5 days, and 14 patients (six men and eight women; mean age 63.2 ± 13.9 years; nine hemorrhagic stroke and five ischemic stroke) underwent rehabilitation using a single type of HAL robot for 14.9 ± 8.9 days. The multiple-robot rehabilitation group showed significantly better outcomes in the Brunnstrom stage of the upper extremity, BI, and FIM scores. To the best of the authors' knowledge, this is the first pilot study demonstrating the feasibility of rehabilitation using multiple exoskeleton robots. The tailor-made rehabilitation approach may be useful for the treatment of acute stroke.

  4. Robot-Assisted Middle Pancreatectomy for Elderly Patients: Our Initial Experience

    Science.gov (United States)

    Zhang, Tian; Wang, Xinjing; Huo, Zhen; Wen, Chenlei; Wu, Zhichong; Zhan, Qian; Jin, Jiabin; Cheng, Dongfeng; Chen, Hao; Deng, Xiaxing; Shen, Baiyong; Peng, Chenghong

    2015-01-01

    Background The aim of this study was to evaluate the indications, safety, feasibility, and short- and long-term outcomes for elderly patients who underwent robot-assisted middle pancreatectomies (MPs). Material/Methods Ten patients (≥60 years) underwent robot-assisted middle pancreatectomies from 2012 to 2015. The perioperative data, including tumor size, operating time, rate of postoperative pancreatic fistula (POPF), postoperative morbidity, and other parameters, were analyzed. We collected and analyzed the follow-up information. Results The mean age of patients was 64.30 years (range, 60–73 years). The average tumor size was 2.61 cm. The 10 cases were all benign or low-grade malignant lesions. The mean operating time was 175.00 min. The mean blood loss was 113.00 ml with no blood transfusion needed. Postoperative fistulas developed in 5 patients; there were 2 Grade A fistulas and 3 grade B fistulas. There were 3 patients who underwent postoperative complications, including 2 Grade 1 or 2 complications and 1 Grade 3 complication. No reoperation and postoperative mortality occurred. The mean hospital stay was 19.91 days. After a median follow-up of 23 months, new onset of diabetes mellitus developed in 1 patient and none suffered from deterioration of previously diagnosed diabetes or exocrine insufficiency, and no tumor recurrence happened. Conclusions Robot-assisted middle pancreatectomy was safe and feasible for elderly people. It had low risk of exocrine or endocrine dysfunction and benefited patients’ long-term outcomes. Incidence of POPF was relatively high but we could prevent it from resulting in bad outcomes by scientific perioperative care and systemic treatment. PMID:26395335

  5. A comparison of quality outcome measures in patients having a hysterectomy for benign disease: robotic vs. non-robotic approaches.

    Science.gov (United States)

    Martino, Martin A; Berger, Elizabeth A; McFetridge, Jeffrey T; Shubella, Jocelyn; Gosciniak, Gabrielle; Wejkszner, Taylor; Kainz, Gregory F; Patriarco, Jeremy; Thomas, M Bijoy; Boulay, Richard

    2014-01-01

    To measure procedure-related hospital readmissions within 30 days after discharge for patients who have a hysterectomy for benign disease. Secondary outcome quality measures evaluated were cost, estimated blood loss, length of stay and sum of costs associated with readmissions. Retrospective cohort study (Canadian Task Force classification II-2). Academic community hospital. Patients who underwent hysterectomy to treat benign disease from January 2008 to December 2012. Patients were grouped according to route of hysterectomy: robotic-assisted laparoscopic hysterectomy (robotic), laparoscopic hysterectomy (laparoscopic), abdominal hysterectomy (open via laparotomy), and vaginal hysterectomy (vaginal). Inclusion criteria were met by 2554 patients: 601 in the robotic group, 427 in the laparoscopic group, 1194 in the abdominal group, and 332 in the vaginal group. Readmission rates in the robotic cohort were significantly less (probotic cohorts: Robotic (1%), laparoscopic (2.5%), open (3.5%), vaginal (2.4%). Estimated blood loss, length of stay, and sum of readmission costs were also significantly less in the robotic cohort (probotic-assisted laparoscopic hysterectomy have a significantly lower chance of readmission robotics cohort also experienced a shorter length of stay, less estimated blood loss, and a cost savings associated with readmissions when compared to non-robotic approaches. Prospective registries describing quality outcomes, total sum of costs including 30 days follow-up, as well as patient-related quality of life benefits are recommended to confirm these findings and determine which surgical route offers the highest patient and societal value. Copyright © 2014. Published by Elsevier Inc.

  6. Impact of robotics on the outcome of elderly patients with endometrial cancer.

    Science.gov (United States)

    Lavoue, Vincent; Zeng, Xing; Lau, Susie; Press, Joshua Z; Abitbol, Jeremie; Gotlieb, Raphael; How, Jeffrey; Wang, Yifan; Gotlieb, Walter H

    2014-06-01

    To evaluate the impact of introducing a robotics program on clinical outcome of elderly patients with endometrial cancer. Evaluation and comparison of peri-operative morbidity and disease-free interval in 163 consecutive elderly patients (≥70years) with endometrial cancer undergoing staging procedure with traditional open surgery compared to robotic surgery. All consecutive patients ≥70years of age with endometrial cancer who underwent robotic surgery (n=113) were compared with all consecutive patients ≥70years of age (n=50) before the introduction of a robotic program in December 2007. Baseline patient characteristics were similar in both eras. Patients undergoing robotic surgery had longer mean operating times (244 compared with 217minutes, p=0.009) but fewer minor adverse events (17% compared with 60%, probotics cohort had less estimated mean blood loss (75 vs 334mL, probotics program for the treatment of endometrial cancer in the elderly has significant benefits, including lower minor complication rate, less operative blood loss and shorter hospitalization without compromising 2-year disease-free survival. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Robotic transthoracic esophagectomy.

    Science.gov (United States)

    Puntambekar, Shailesh; Kenawadekar, Rahul; Kumar, Sanjay; Joshi, Saurabh; Agarwal, Geetanjali; Reddy, Sunil; Mallik, Jainul

    2015-04-23

    We have initially published our experience with the robotic transthoracic esophagectomy in 32 patients from a single institute. The present paper is the extension of our experience with robotic system and to best of our knowledge this represents the largest series of robotic transthoracic esophagectomy worldwide. The objective of this study was to investigate the feasibility of the robotic transthoracic esophagectomy for esophageal cancer in a series of patients from a single institute. A retrospective review of medical records was conducted for 83 esophageal cancer patients who underwent robotic esophagectomy at our institute from December 2009 to December 2012. All patients underwent a thorough clinical examination and pre-operative investigations. All patients underwent robotic esophageal mobilization. En-bloc dissection with lymphadenectomy was performed in all cases with preservation of Azygous vein. Relevant data were gathered from medical records. The study population comprised of 50 men and 33 women with mean age of 59.18 years. The mean operative time was 204.94 mins (range 180 to 300). The mean blood loss was 86.75 ml (range 50 to 200). The mean number of lymph node yield was 18. 36 (range 13 to 24). None of the patient required conversion. The mean ICU stay and hospital stay was 1 day (range 1 to 3) and 10.37 days (range 10 to 13), respectively. A total of 16 (19.28%) complication were reported in these patents. Commonly reported complication included dysphagia, pleural effusion and anastomotic leak. No treatment related mortality was observed. After a median follow-up period of 10 months, 66 patients (79.52%) survived with disease free stage. We found robot-assisted thoracoscopic esophagectomy feasible in cases of esophageal cancer. The procedure allowed precise en-bloc dissection with lymphadenectomy in mediastinum with reduced operative time, blood loss and complications.

  8. Outcomes in patients undergoing robotic reconstructive uterovaginal anastomosis of congenital cervical and vaginal atresia.

    Science.gov (United States)

    Zhang, Ying; Chen, Yisong; Hua, Keqin

    2017-09-01

    To introduce our experience of robotic surgery of reconstructive uterovaginal anastomosis and operative outcomes in congenital cervical and vaginal atresia patients. Clinical observation and follow-up of four patients with congenital cervical and vaginal atresia who underwent robotic reconstruction of cervix and vagina by SIS (small intestinal submucosa, SIS) graft. Average patient age was 13.8 ± 2.2. Patients complained of severe periodic abdominal pain. Diagnosis was made according to clinical characteristics, physical examination, MRI and classified by ESHRE/ESGE system. All patients underwent reconstruction of cervix and vagina by uterovaginal anastomosis by SIS graft. Average operation time was 232.5 ± 89.2 min, average blood loss was 225.0 ± 95.7 mL. After surgery, all patients have regular menstruation without pain. Average follow up was 12 months, average vagina length was 8.9 ± 0.3 cm, average vagina width was 2.9 ± 0.1 cm. Robotic assisted reconstruction of cervix and vagina is feasible from our experience, enlarged cases and additional studies are required. © 2017 The Authors The International Journal of Medical Robotics and Computer Assisted Surgery Published by John Wiley & Sons Ltd.

  9. Robotic presacral neurectomy - technique and results.

    Science.gov (United States)

    Kapetanakis, Vasilis; Jacob, Kristina; Klauschie, Jennifer; Kho, Rosanne; Magrina, Javier

    2012-03-01

    The feasibility, safety and outcomes of robotic presacral neurectomy were evaluated. A retrospective analysis was performed of 33 patients with midline chronic pelvic pain, who underwent robotic presacral neurectomy. Data were collected during the period March 2004-March 2010. All patients underwent robotic presacral neurectomy and additional robotic procedures. Mean operating time for robotic presacral neurectomy was 5.8 (range 4.4-6.9) min. Mean blood loss, including concomitant procedures, was 39 (range 15-150) ml. Most patients were discharged the same day (60%) and mean hospital stay was 0.39 (range 0-2) days. There were no conversions or intra-operative complications. There were two postoperative complications: one pelvic abscess and one Clostridium difficile colitis. Pain improvement was reported by 73% (22/30) of patients. Robotic presacral neurectomy is safe and feasible, resulting in improvement of pelvic pain in selected patients. Copyright © 2011 John Wiley & Sons, Ltd.

  10. Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program

    Directory of Open Access Journals (Sweden)

    Gokhan Sami Kilic

    2011-01-01

    Full Text Available Study Objective. Prospectively compare outcomes of robotically assisted and laparoscopic hysterectomy in the process of implementing a new robotic program. Design. Prospectively comparative observational nonrandomized study. Design Classification. II-1. Setting. Tertiary caregiver university hospital. Patients. Data collected consecutively 24 months, 34 patients underwent laparoscopic hysterectomy, 25 patients underwent robotic hysterectomy, and 11 patients underwent vaginal hysterectomy at our institution. Interventions. Outcomes of robotically assisted, laparoscopic, and vaginal complex hysterectomies performed by a single surgeon for noncancerous indications. Measurements and Main Results. Operative times were 208.3±59.01 minutes for laparoscopic, 286.2±82.87 minutes for robotic, and 163.5±61.89 minutes for vaginal (<.0001. Estimated blood loss for patients undergoing laparoscopic surgery was 242.7±211.37 cc, 137.4±107.50 cc for robotic surgery, and 243.2±127.52 cc for vaginal surgery (=0.05. The mean length of stay ranged from 1.8 to 2.3 days for the 3 methods. Association was significant for uterine weight (=0.0043 among surgery methods. Conclusion. Robotically assisted hysterectomy is feasible with low morbidity, a shorter hospital stay, and less blood loss. This suggests that robotic assistance facilitates a minimally invasive approach for patients with larger uterine size even during implementing a new robotic program.

  11. Robotic surgery in supermorbidly obese patients with endometrial cancer.

    Science.gov (United States)

    Stephan, Jean-Marie; Goodheart, Michael J; McDonald, Megan; Hansen, Jean; Reyes, Henry D; Button, Anna; Bender, David

    2015-07-01

    Morbid obesity is a known risk factor for the development of endometrial cancer. Several studies have demonstrated the overall feasibility of robotic-assisted surgical staging for endometrial cancer as well as the benefits of robotics compared with laparotomy. However, there have been few reports that have evaluated robotic surgery for endometrial cancer in the supermorbidly obese population (body mass index [BMI], ≥50 kg/m(2)). We sought to evaluate safety, feasibility, and outcomes for supermorbidly obese patients who undergo robotic surgery for endometrial cancer, compared with patients with lower body mass indices. We performed a retrospective chart review of 168 patients with suspected early-stage endometrial adenocarcinoma who underwent robotic surgery for the management of their disease. Analysis of variance and univariate logistic regression were used to compare patient characteristics and surgical variables across all body weights. Cox proportional hazard regression was used to determine the impact of body weight on recurrence-free and overall survival. The mean BMI of our cohort was 40.9 kg/m(2). Median follow up was 31 months. Fifty-six patients, 30% of which had grade 2 or 3 tumors, were supermorbidly obese with a BMI of ≥50 kg/m(2) (mean, 56.3 kg/m(2)). A comparison between the supermorbidly obese and lower-weight patients demonstrated no differences in terms of length of hospital stay, blood loss, complication rates, numbers of pelvic and paraaortic lymph nodes retrieved, or recurrence and survival. There was a correlation between BMI and conversion to an open procedure, in which the odds of conversion increased with increasing BMI (P = .02). Offering robotic surgery to supermorbidly obese patients with endometrial cancer is a safe and feasible surgical management option. When compared with patients with a lower BMI, the supermorbidly obese patient had a similar outcome, length of hospital stay, blood loss, complications, and numbers of lymph

  12. Robot-assisted Heller's myotomy for achalasia in children.

    Science.gov (United States)

    Altokhais, Tariq; Mandora, Hala; Al-Qahtani, Ayed; Al-Bassam, Abdulrahman

    2016-12-01

    Achalasia is rare in children. Surgical options include open, laparoscopic and robotic approaches. However, Heller's myotomy remains the treatment of choice. This report describes our experience with robot-assisted Heller's myotomy in children and presents a review of the literature. Included in this study are children who underwent robot-assisted Heller's myotomy for esophageal achalasia via the Da Vinci surgical system between 2004 and 2015 at King Saud University Medical City, Riyadh, Saudi Arabia. The medical records of these patients were reviewed for demographic data, presenting symptoms, diagnostic modalities, operative procedures, complications, outcomes and follow-ups. Six patients were identified. The age of the patients at surgery ranged between 2 and 12 years (mean 7.1 years). The most common presenting symptoms were dysphagia, vomiting and nocturnal cough. Contrast swallow and upper gastrointestinal endoscopy established a diagnosis of esophageal achalasia in all of the patients. Four patients underwent esophageal dilatation 2-5 times before the definitive procedure. All patients underwent successful robot-assisted Heller's myotomy with concomitant partial posterior fundoplication. The postoperative course was uneventful. Five patients had a complete resolution of the symptoms and one patient improved. The follow-up assessments have been consistent and have ranged from 0.5 to 11 years (mean 4.4 years). Robotic-assisted Heller's myotomy for esophageal achalasia in children is safe and effective and is a suitable alternative to open and laparoscopic approaches.

  13. Da Vinci robot-assisted system for thymectomy: experience of 55 patients in China.

    Science.gov (United States)

    Jun, Yi; Hao, Li; Demin, Li; Guohua, Dong; Hua, Jing; Yi, Shen

    2014-09-01

    Da Vinci robot-assisted thymectomy has been used in the past several years in China, however, practical experience in performing this approach in China remains limited. Thus, the study aimed to evaluate the experience of da Vinci robot-assisted thymectomy in China. From June 2010 to December 2012, 55 patients with diseases of the thymus underwent thymectomy using the da Vinci surgical HD robotic system. The clinical data of the da Vinci robot-assisted thymectomies were compared with the data of video-assisted thoracoscopic thymectomies in the same period. All da Vinci robot operations were successful. This is a retrospective analysis which demonstrated that compared with video-assisted thoracoscopic thymectomy in the same period, the clinical outcomes of da Vinci robot-assisted thymectomy were not significantly different. The da Vinci robot-assisted thymectomy is a safe, minimally invasive, and convenient operation, and shows promise for general thoracic surgery in China. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Robotic assisted gastrectomy compared with open resection: a case-matched study.

    Science.gov (United States)

    Caruso, Riccardo; Vicente, Emilio; Quijano, Yolanda; Ielpo, Benedetto; Duran, Hipolito; Diaz, Eduardo; Fabra, Isabel; Ferri, Valentina

    2018-05-04

    In recent years, increasingly sophisticated tools have allowed for more complex robotic surgery. Robotic gastrectomy, however, is adopted in only a few selected centers. The goals of this study were to examine the adoption of robotic gastrectomy and to compare outcomes between open and robotic gastric resections. This is a case-matched analysis of patients who underwent robotic and open gastric resection performed at Sanchinarro University Hospital, Madrid from November 2011 to February 2017. Patient data were obtained retrospectively. Clinicopathologic characteristics and perioperative and postoperative outcomes were recorded and analyzed. Two groups of demographically similar patients were analyzed: the robotic group (n = 20) and the open surgery group (n = 19). The patient characteristics of the two groups have been compared. Robotic resection resulted in less blood loss, shorter postoperative hospital stay, and a longer operating time. The two groups had similar complication rates. Pathological data were similar for both procedures. Robotic gastrectomy for locally advanced gastric carcinoma is safe, and long-term outcomes are comparable to those patients who underwent open resection. Robotic gastrectomy resulted in a shorter hospital stay, less blood loss and morbidity comparable with the outcomes of open gastrectomy.

  15. [Anesthesia experiences on laparoscopic nephrectomy with da Vinci S robotics].

    Science.gov (United States)

    Mou, Ling; Lan, Zhixun

    2015-09-01

    To summarize the clinical anesthesia experiences in 20 patients who underwent laparoscopic nephrectomy with da Vinci S robotics.
 Anesthesia data of 20 patients from Sichuan Provincial People's Hospital, who underwent laparoscopic nephrectomy with da Vinci S robotics from August 2014 to November 2014, were analyzed and summarized. The anesthesia time, operation time, CO(2) pneumoperitoneum time, PaCO(2) and PETCO(2) were recorded.
 All patients were anesthetized and underwent surgery with da Vinci S robotics. The anesthesia time was (220±14) min, the operation time was (187±11) min, and the CO(2) pneumoperitoneum time was (180±13) min. The PaCO(2) and PETCO(2) were significantly elevated at 1.5 h after operation compared with those at the baseline (before pneumoperitoneum) (Pda vinci S robotics. However, the duration of CO(2) pneumoperitoneum is significantly increased compared to that of other surgical procedures, resulting in high airway resistance and acid-base disturbance.

  16. Laparoscopy vs robotics in surgical management of endometrial cancer: comparison of intraoperative and postoperative complications.

    Science.gov (United States)

    Seror, Julien; Bats, Anne-Sophie; Huchon, Cyrille; Bensaïd, Chérazade; Douay-Hauser, Nathalie; Lécuru, Fabrice

    2014-01-01

    To compare the rates of intraoperative and postoperative complications of robotic surgery and laparoscopy in the surgical treatment of endometrial cancer. Unicentric retrospective study (Canadian Task Force classification II-2). Tertiary teaching hospital. The study was performed from January 2002 to December 2011 and included patients with endometrial cancer who underwent laparoscopic or robotically assisted laparoscopic surgical treatment. Data collected included preoperative data, tumor characteristics, intraoperative data (route of surgery, surgical procedures, and complications), and postoperative data (early and late complications according to the Clavien-Dindo classification, and length of hospital stay). Morbidity was compared between the 2 groups. The study included 146 patients, of whom 106 underwent laparoscopy and 40 underwent robotically assisted surgery. The 2 groups were comparable in terms of demographic and preoperative data. Intraoperative complications occurred in 9.4% of patients who underwent laparoscopy and in none who underwent robotically assisted surgery (p = .06). There was no difference between the 2 groups in terms of postoperative events. Robotically assisted surgery is not associated with a significant difference in intraoperative and postoperative complications, even when there were no intraoperative complications of robotically assisted surgery. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  17. Patient body image, self-esteem, and cosmetic results of minimally invasive robotic cardiac surgery.

    Science.gov (United States)

    İyigün, Taner; Kaya, Mehmet; Gülbeyaz, Sevil Özgül; Fıstıkçı, Nurhan; Uyanık, Gözde; Yılmaz, Bilge; Onan, Burak; Erkanlı, Korhan

    2017-03-01

    Patient-reported outcome measures reveal the quality of surgical care from the patient's perspective. We aimed to compare body image, self-esteem, hospital anxiety and depression, and cosmetic outcomes by using validated tools between patients undergoing robot-assisted surgery and those undergoing conventional open surgery. This single-center, multidisciplinary, randomized, prospective study of 62 patients who underwent cardiac surgery was conducted at Hospital from May 2013 to January 2015. The patients were divided into two groups: the robotic group (n = 33) and the open group (n = 29). The study employed five different tools to assess body image, self-esteem, and overall patient-rated scar satisfaction. There were statistically significant differences between the groups in terms of self-esteem scores (p = 0.038), body image scores (p = 0.026), overall Observer Scar Assessment Scale (p = 0.013), and overall Patient Scar Assessment Scale (p = 0.036) scores in favor of the robotic group during the postoperative period. Robot-assisted surgery protected the patient's body image and self-esteem, while conventional open surgery decreased these levels but without causing pathologies. Preoperative depression and anxiety level was reduced by both robot-assisted surgery and conventional open surgery. The groups did not significantly differ on Patient Satisfaction Scores and depression/anxiety scores. The results of this study clearly demonstrated that a minimally invasive approach using robotic-assisted surgery has advantages in terms of body image, self-esteem, and cosmetic outcomes over the conventional approach in patients undergoing cardiac surgery. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Reverse-hybrid robotic mesorectal excision for rectal cancer.

    Science.gov (United States)

    Park, In Ja; You, Y Nancy; Schlette, Erika; Nguyen, Sa; Skibber, John M; Rodriguez-Bigas, Miguel A; Chang, George J

    2012-02-01

    The robotic system offers potential technical advantages over laparoscopy for total mesorectal excision with radical lymphadenectomy for rectal cancer. However, the requirement for fixed docking limits its utility when the working volume is large or patient repositioning is required. The purpose of this study was to evaluate short-term outcomes associated with a novel setup to perform total mesorectal excision and radical lymphadenectomy for rectal cancer by the use of a "reverse" hybrid robotic-laparoscopic approach. This is a prospective consecutive cohort observational study of patients who underwent robotic rectal cancer resection from January 2009 to March 2011. During the study period, a technique of reverse-hybrid robotic-laparoscopic rectal resection with radical lymphadenectomy was developed. This technique involves reversal of the operative sequence with lymphovascular and rectal dissection to precede proximal colonic mobilization. This technique evolved from a conventional-hybrid resection with laparoscopic vascular control, colonic mobilization, and robotic pelvic dissection. Perioperative and short-term oncologic outcomes were analyzed. Thirty patients underwent reverse-hybrid resection. Median tumor location was 5 cm (interquartile range 3-9) from the anal verge. Median BMI was 27.6 (interquartile range 25.0-32.1 kg/m). Twenty (66.7%) received neoadjuvant chemoradiation. There were no conversions. Median blood loss was 100 mL (interquartile range 75-200). Total operation time was a median 369 (interquartile range 306-410) minutes. Median docking time was 6 (interquartile range 5-8) minutes, and console time was 98 (interquartile range 88-140) minutes. Resection was R0 in all patients; no patients had an incomplete mesorectal resection. Six patients (20%) underwent extended lymph node dissection or en bloc resection. Reverse-hybrid robotic surgery for rectal cancer maximizes the therapeutic applicability of the robotic and conventional laparoscopic

  19. Robotic versus laparoscopic resection of liver tumours

    Science.gov (United States)

    Berber, Eren; Akyildiz, Hizir Yakup; Aucejo, Federico; Gunasekaran, Ganesh; Chalikonda, Sricharan; Fung, John

    2010-01-01

    Background There are scant data in the literature regarding the role of robotic liver surgery. The aim of the present study was to develop techniques for robotic liver tumour resection and to draw a comparison with laparoscopic resection. Methods Over a 1-year period, nine patients underwent robotic resection of peripherally located malignant lesions measuring <5 cm. These patients were compared prospectively with 23 patients who underwent laparoscopic resection of similar tumours at the same institution. Statistical analyses were performed using Student's t-test, χ2-test and Kaplan–Meier survival. All data are expressed as mean ± SEM. Results The groups were similar with regards to age, gender and tumour type (P = NS). Tumour size was similar in both groups (robotic −3.2 ± 1.3 cm vs. laparoscopic −2.9 ± 1.3 cm, P = 0.6). Skin-to-skin operative time was 259 ± 28 min in the robotic vs. 234 ± 17 min in the laparoscopic group (P = 0.4). There was no difference between the two groups regarding estimated blood loss (EBL) and resection margin status. Conversion to an open operation was only necessary in one patient in the robotic group. Complications were observed in one patient in the robotic and four patients in the laparoscopic groups. The patients were followed up for a mean of 14 months and disease-free survival (DFS) was equivalent in both groups (P = 0.6). Conclusion The results of this initial study suggest that, for selected liver lesions, a robotic approach provides similar peri-operative outcomes compared with laparoscopic liver resection (LLR). PMID:20887327

  20. Robotic Assisted Transanal Polypectomies: Is There Any Indication?

    Science.gov (United States)

    Gómez Ruiz, Marcos; Cagigas Fernández, Carmen; Alonso Martín, Joaquín; Cristobal Poch, Lidia; Manuel Palazuelos, Carlos; Barredo Cañibano, Francisco Javier; Gómez Fleitas, Manuel; Castillo Diego, Julio

    2017-12-01

    Robotic assisted transanal polipectomy may have advantages compared with the conventional transanal minimally invasive surgery technique. We evaluate the safety, feasibility and advantages of this technique. Between February 2014 and October 2015, 9patients underwent robotic transanal polypectomy. We performed a retrospective study in which we analyse prospectively collected data regarding patient and tumor characteristics, perioperative outcomes, pathological report, morbidity and mortality. A total of 5 male and 4 female patients underwent robotic TAMIS. Lesions were 6,22cm from the anal verge. Mean size was 15,8cm 2 . All procedures were performed in the lithotomy position. Closure of the defect was performed in all cases. Mean blood loss was 39,8ml. Mean operative time was 71,9min. No severe postoperative complications or readmissions occured. Median hospital stay was 2,5 days. Robotic TAMIS is useful to treat complex rectal lesions. Our transanal platform allowed a wider range of movements of the robotic arms and to perform all procedures in the lithotomy position. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Development of robotic program: an Asian experience.

    Science.gov (United States)

    Sahabudin, R M; Arni, T; Ashani, N; Arumuga, K; Rajenthran, S; Murali, S; Patel, V; Hemal, A; Menon, M

    2006-06-01

    Robotic surgery was started in the Department of Urology, Hospital Kuala Lumpur, in April 2004. We present our experience in developing the program and report the results of our first 50 cases of robotic radical prostatectomy. A three-arm da Vinci robotic system was installed in our hospital in March 2004. Prior to installation, the surgeons underwent training at various centers in the United States and Paris. The operating theatre was renovated to house the system. Subsequently, the initial few cases were done with the help of proctors. Data were prospectively collected on all patients who underwent robot-assisted radical prostatectomy for localized carcinoma of the prostate. Fifty patients underwent robot assisted radical prostatectomy from March 2004 to June 2005. Their ages ranged from 52 to 75 years, (average age 60.2 years). PSA levels ranged from 2.5 to 35 ng/ml (mean 10.6 ng/ml). Prostate volume ranged from 18 to 130 cc (average 32.4 cc). Average operating time for the first 20 cases was 4 h and for the next 30 cases was 2.5 h. Patients were discharged 1-3 days post-operatively. Catheters were removed on the fifth day following a cystogram. The positive margin rate as defined by the presence of cancer cells at the inked margin was 30%. Twenty-one patients had T1c disease and one had T1b on clinical staging. Of these, two were apical margin positive. Twenty-six patients had T2 disease and eight of them were apical margin positive. Two patients had T3 disease, one of whom was apical margin positive. Five patients (10%) had PSA recurrence. Five patients had a poorly differentiated carcinoma and the rest had Gleason 6 or 7. Eighty percent of the patients were continent on follow-up at 3 months. Of those who were potent before the surgery, 50% were potent at 3-6 months. The robotic surgery program was successfully implemented at our center on the lines of a structured program, developed at Vattikuti Urology Institute (VUI). We succeeded in creating a team and

  2. Robot-assisted laparoscopic versus open partial nephrectomy in patients with chronic kidney disease: A propensity score-matched comparative analysis of surgical outcomes.

    Science.gov (United States)

    Takagi, Toshio; Kondo, Tsunenori; Tachibana, Hidekazu; Iizuka, Junpei; Omae, Kenji; Kobayashi, Hirohito; Yoshida, Kazuhiko; Tanabe, Kazunari

    2017-07-01

    To compare surgical outcomes between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy in patients with chronic kidney disease. Of 550 patients who underwent partial nephrectomy between 2012 and 2015, 163 patients with T1-2 renal tumors who had an estimated glomerular filtration rate between 30 and 60 mL/min/1.73 m 2 , and underwent robot-assisted laparoscopic partial nephrectomy or open partial nephrectomy were retrospectively analyzed. To minimize selection bias between the two surgical methods, patient variables were adjusted by 1:1 propensity score matching. The present study included 75 patients undergoing robot-assisted laparoscopic partial nephrectomy and 88 undergoing open partial nephrectomy. After propensity score matching, 40 patients were included in each operative group. The mean preoperative estimated glomerular filtration rate was 49 mL/min/1.73 m 2 . The mean ischemia time was 21 min in robot-assisted laparoscopic partial nephrectomy (warm ischemia) and 35 min in open partial nephrectomy (cold ischemia). Preservation of the estimated glomerular filtration rate 3-6 months postoperatively was not significantly different between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy (92% vs 91%, P = 0.9348). Estimated blood loss was significantly lower in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (104 vs 185 mL, P = 0.0025). The postoperative length of hospital stay was shorter in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (P negative surgical margin status were not significantly different between the two groups. In our experience, robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy provide similar outcomes in terms of functional preservation and perioperative complications among patients with chronic kidney disease. However, a lower estimated blood loss and

  3. Robot-assisted arm assessments in spinal cord injured patients: a consideration of concept study.

    Directory of Open Access Journals (Sweden)

    Urs Keller

    Full Text Available Robotic assistance is increasingly used in neurological rehabilitation for enhanced training. Furthermore, therapy robots have the potential for accurate assessment of motor function in order to diagnose the patient status, to measure therapy progress or to feedback the movement performance to the patient and therapist in real time. We investigated whether a set of robot-based assessments that encompasses kinematic, kinetic and timing metrics is applicable, safe, reliable and comparable to clinical metrics for measurement of arm motor function. Twenty-four healthy subjects and five patients after spinal cord injury underwent robot-based assessments using the exoskeleton robot ARMin. Five different tasks were performed with aid of a visual display. Ten kinematic, kinetic and timing assessment parameters were extracted on joint- and end-effector level (active and passive range of motion, cubic reaching volume, movement time, distance-path ratio, precision, smoothness, reaction time, joint torques and joint stiffness. For cubic volume, joint torques and the range of motion for most joints, good inter- and intra-rater reliability were found whereas precision, movement time, distance-path ratio and smoothness showed weak to moderate reliability. A comparison with clinical scores revealed good correlations between robot-based joint torques and the Manual Muscle Test. Reaction time and distance-path ratio showed good correlation with the "Graded and Redefined Assessment of Strength, Sensibility and Prehension" (GRASSP and the Van Lieshout Test (VLT for movements towards a predefined position in the center of the frontal plane. In conclusion, the therapy robot ARMin provides a comprehensive set of assessments that are applicable and safe. The first results with spinal cord injured patients and healthy subjects suggest that the measurements are widely reliable and comparable to clinical scales for arm motor function. The methods applied and results can

  4. Robotic Versus Laparoscopic Colorectal Cancer Surgery in Elderly Patients: A Propensity Score Match Analysis.

    Science.gov (United States)

    de'Angelis, Nicola; Abdalla, Solafah; Bianchi, Giorgio; Memeo, Riccardo; Charpy, Cecile; Petrucciani, Niccolo; Sobhani, Iradj; Brunetti, Francesco

    2018-05-31

    Minimally invasive surgery in elderly patients with colorectal cancer remains controversial. The study aimed to compare the operative, postoperative, and oncologic outcomes of robotic (robotic colorectal resection surgery [RCRS]) versus laparoscopic colorectal resection surgery (LCRS) in elderly patients with colorectal cancer. Propensity score matching (PSM) was used to compare patients aged 70 years and more undergoing elective RCRS or LCRS for colorectal cancer between 2010 and 2017. Overall, 160 patients underwent elective curative LCRS (n = 102) or RCRS (n = 58) for colorectal cancer. Before PSM, the mean preoperative Charlson score and the tumor size were significantly lower in the robotic group. After matching, 43 RCRSs were compared with 43 LCRSs. The RCRS group showed longer operative times (300.6 versus 214.5 min, P = .03) compared with LCRS, but all other operative variables were comparable between the two groups. No differences were found for postoperative morbidity, mortality, time to flatus, return to regular diet, and length of hospital stay. R0 resection was obtained in 95.3% of procedures. The overall and disease-free survival rates at 1, 2, and 3 years were similar between RCRS and LCRS patients. The presence of more than one comorbidity before surgery was significantly associated with the incidence of postoperative complications. In patients aged 70 years or more, robotic colorectal surgery showed operative and oncologic outcomes similar to those obtained by laparoscopy, despite longer operative times. Randomized trials are awaited to reliably assess the clinical and oncological noninferiority and the costs/benefits ratio of robotic colorectal surgery in elderly populations.

  5. Outcomes and cost comparisons after introducing a robotics program for endometrial cancer surgery.

    Science.gov (United States)

    Lau, Susie; Vaknin, Zvi; Ramana-Kumar, Agnihotram V; Halliday, Darron; Franco, Eduardo L; Gotlieb, Walter H

    2012-04-01

    To evaluate the effect of introducing a robotic program on cost and patient outcome. This was a prospective evaluation of clinical outcome and cost after introducing a robotics program for the treatment of endometrial cancer and a retrospective comparison to the entire historical cohort. Consecutive patients with endometrial cancer who underwent robotic surgery (n=143) were compared with all consecutive patients who underwent surgery (n=160) before robotics. The rate of minimally invasive surgery increased from 17% performed by laparoscopy to 98% performed by robotics in 2 years. The patient characteristics were comparable in both eras, except for a higher body mass index in the robotics era (median 29.8 compared with 27.6; Probotics had longer operating times (233 compared with 206 minutes), but fewer adverse events (13% compared with 42%; Probotics compared with the historical group (Can$7,644 compared with Can$10,368 [Canadian dollars]; Psurgery, the short-term recurrence rate appeared lower in the robotics group compared with the historic cohort (11 recurrences compared with 19 recurrences; Probotics for endometrial cancer surgery increased the proportion of patients benefitting from minimally invasive surgery, improved short-term outcomes, and resulted in lower hospital costs. II.

  6. Distal pancreatectomy and splenectomy: a robotic or LESS approach.

    Science.gov (United States)

    Ryan, Carrie E; Ross, Sharona B; Sukharamwala, Prashant B; Sadowitz, Benjamin D; Wood, Thomas W; Rosemurgy, Alexander S

    2015-01-01

    The role and application of robotic surgery are debated, particularly given the expansion of laparoscopy, especially laparoendoscopic single-site (LESS) surgery. This cohort study was undertaken to delineate differences in outcomes between LESS and robotic distal pancreatectomy and splenectomy. With Institutional Review Board approval, patients undergoing LESS or robotic distal pancreatectomy and splenectomy from September 1, 2012, through December 31, 2014, were prospectively observed, and data were collected. The results are expressed as the median, with the mean ± SD. Thirty-four patients underwent a minimally invasive distal pancreatectomy and splenectomy: 18 with robotic and 16 with LESS surgery. The patients were similar in sex, age, and body mass index. Conversions to open surgery and estimated blood loss were similar. There were two intraoperative complications in the group that underwent the robotic approach. Time spent in the operating room was significantly longer with the robot (297 vs 254 minutes, P = .03), although operative duration (i.e., incision to closure) was not longer (225 vs 190 minutes; P = .15). Of the operations studied, 79% were undertaken for neoplastic processes. Tumor size was 3.5 cm for both approaches; R0 resections were achieved in all patients. Length of stay was similar in the two study groups (5 vs 4 days). There was one 30-day readmission after robotic surgery. Patient outcomes are similar with LESS or robotic distal pancreatectomy and splenectomy. Robotic operations require more time in the operating room. Both are safe and efficacious minimally invasive operations that follow similar oncologic principles for similar tumors, and both should be in the surgeon's armamentarium for distal pancreatectomy and splenectomy.

  7. Evolution of upper limb kinematics four years after subacute robot-assisted rehabilitation in stroke patients.

    Science.gov (United States)

    Pila, Ophélie; Duret, Christophe; Gracies, Jean-Michel; Francisco, Gerard E; Bayle, Nicolas; Hutin, Émilie

    2018-04-25

    To assess functional status and robot-based kinematic measures four years after subacute robot-assisted rehabilitation in hemiparesis. Twenty-two patients with stroke-induced hemiparesis underwent a ≥3-month upper limb combined program of robot-assisted and occupational therapy from two months post-stroke, and received community-based therapy after discharge. Four years later, 19 (86%) participated in this follow-up study. Assessments 2, 5 and 54 months post-stroke included Fugl-Meyer (FM), Modified Frenchay Scale (MFS, at Month 54) and robot-based kinematic measures of targeting tasks in three directions, north, paretic and non-paretic: distance covered, velocity, accuracy (root mean square (RMS) error from straight line) and smoothness (number of velocity peaks; upward changes in accuracy and smoothness represent worsening). Analysis was stratified by FM score at two months: ≥17 (Group 1) or Kinematic changes (three directions pooled) were: distance -1[-17;2]% (ns); velocity, -8[-32;28]% (ns); accuracy, +6[-13;98]% (ns); smoothness, +44[-6;126]% (p robot-assisted upper limb training during subacute post-stroke phase, movement kinematics deteriorated despite community-based therapy, especially in more severely impaired patients. EudraCT 2016-005121-36. Registration: 2016-12-20. Date of enrolment of the first participant to the trial: 2009-11-24.

  8. Robot assistant versus human or another robot assistant in patients undergoing laparoscopic cholecystectomy.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Samraj, Kumarakrishnan; Fusai, Giuseppe; Davidson, Brian R

    2012-09-12

    The role of a robotic assistant in laparoscopic cholecystectomy is controversial. While some trials have shown distinct advantages of a robotic assistant over a human assistant others have not, and it is unclear which robotic assistant is best. The aims of this review are to assess the benefits and harms of a robot assistant versus human assistant or versus another robot assistant in laparoscopic cholecystectomy, and to assess whether the robot can substitute the human assistant. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded (until February 2012) for identifying the randomised clinical trials. Only randomised clinical trials (irrespective of language, blinding, or publication status) comparing robot assistants versus human assistants in laparoscopic cholecystectomy were considered for the review. Randomised clinical trials comparing different types of robot assistants were also considered for the review. Two authors independently identified the trials for inclusion and independently extracted the data. We calculated the risk ratio (RR) or mean difference (MD) with 95% confidence interval (CI) using the fixed-effect and the random-effects models based on intention-to-treat analysis, when possible, using Review Manager 5. We included six trials with 560 patients. One trial involving 129 patients did not state the number of patients randomised to the two groups. In the remaining five trials 431 patients were randomised, 212 to the robot assistant group and 219 to the human assistant group. All the trials were at high risk of bias. Mortality and morbidity were reported in only one trial with 40 patients. There was no mortality or morbidity in either group. Mortality and morbidity were not reported in the remaining trials. Quality of life or the proportion of patients who were discharged as day-patient laparoscopic cholecystectomy patients were not reported in any

  9. Robotic Buccal Ureteroplasty: a Review of the Current Literature.

    Science.gov (United States)

    Waldorf, Benjamin; Lee, Ziho; Kidd, Laura; Kaplan, Joshua; Harris, Andrew; Metro, Michael; Liu, Jeffrey; Eun, Daniel

    2017-05-01

    This study aimed to provide an overview of the literature on buccal mucosal ureteroplasty for ureteral stricture disease, with a specific focus on the application of the robotic platform to buccal ureteroplasty. In our review, we highlight the results of Zhao et al. from the New York University School of Medicine Department of Urology, as well as our own results from Temple University Hospital. Zhao et al. published the first series of four patients who underwent robotic buccal ureteroplasty. Mean stricture length was 3.0 cm, and at a mean follow-up of 15 months, all repairs remained patent. We also describe our results in 10 patients who underwent robotic buccal ureteroplasty at Temple University Hospital. Median stricture length was 3.0 cm, and at a median follow-up of 5 months, all repairs remain patent. Robotic buccal ureteroplasty offers a promising option for repair of complex ureteral strictures.

  10. Robotic surgery for rectal cancer: a single center experience of 100 consecutive cases.

    Science.gov (United States)

    Stănciulea, O; Eftimie, M; David, L; Tomulescu, V; Vasilescu, C; Popescu, I

    2013-01-01

    Minimally invasive techniques have revolutionized the field of general surgery over the few last decades. Despite its advantages, in complex procedures such as rectal surgery, laparoscopy has not achieved a high penetration rate because of its steep learning curve, its relatively high conversion rate and technical challenges. The aim of this study was to present a single center experience with robotic surgery for rectal cancer focusing mainly on early and mid-term postoperative outcome. A series of 100 consecutive patients who underwent robotic rectal surgery between January 2008 and June 2012 was analyzed retrospectively in terms of demographics, pathological data, surgical and oncological outcomes. Seventy-seven patients underwent robotic sphincter-saving resection, and 23 patients underwent robotic abdominoperineal resection. There were 4 conversions. The median operative time for sphincter-saving procedures was 180 min. The median time for robotic abdominoperineal resection was 160 min. The median distal resection margin of the operative specimen was 3 cm. The median number of retrieved lymph nodes was 14. The median hospital stay was 10 days. In-hospital mortality was nil. The overall morbidity was 30%. Four patients presented transitory postoperative urinary dysfunction. Severe erectile dysfunction was reported by 3 patients. The median length of follow-up was 24 months. The 3-year overall survival rate was 90%. Robotic surgery is advantageous for both surgeons (in that it facilitates dissection in a narrow pelvis) and patients (in that it affords a very good quality of life via the preservation of sexual and urinary function in the vast majority of patients and it has low morbidity and good midterm oncological outcomes). In rectal cancer surgery, the robotic approach is a promising alternative and is expected to overcome the low penetration rate of laparoscopy in this field. Celsius.

  11. Evolution of elderly patients who underwent cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Alain Moré Duarte

    2016-01-01

    Full Text Available Introduction: There is a steady increase in the number of elderly patients with severe cardiovascular diseases who require a surgical procedure to recover some quality of life that allows them a socially meaningful existence, despite the risks.Objectives: To analyze the behavior of elderly patients who underwent cardiac surgery with cardiopulmonary bypass.Method: A descriptive, retrospective, cross-sectional study was conducted with patients over 65 years of age who underwent surgery at the Cardiocentro Ernesto Che Guevara, in Santa Clara, from January 2013 to March 2014.Results: In the study, 73.1% of patients were men; and there was a predominance of subjects between 65 and 70 years of age, accounting for 67.3%. Coronary artery bypass graft was the most prevalent type of surgery and had the longest cardiopulmonary bypass times. Hypertension was present in 98.1% of patients. The most frequent postoperative complications were renal dysfunction and severe low cardiac output, with 44.2% and 34.6% respectively.Conclusions: There was a predominance of men, the age group of 65 to 70 years, hypertension, and patients who underwent coronary artery bypass graft with prolonged cardiopulmonary bypass. Renal dysfunction was the most frequent complication.

  12. Robot-assisted laparoscopic pyeloplasty: minimum 1-year follow-up

    Science.gov (United States)

    Patel, Vipul; Thaly, Rahul; Shah, Ketul

    2007-02-01

    Objectives: To evaluate the feasibility and efficacy of robotic-assisted laparoscopic pyeloplasty. Laparoscopic pyeloplasty has been shown to have a success rate comparable to that of the open surgical approach. However, the steep learning curve has hindered its acceptance into mainstream urologic practice. The introduction of robotic assistance provides advantages that have the potential to facilitate precise dissection and intracorporeal suturing. Methods: A total of 50 patients underwent robotic-assisted laparoscopic dismembered pyeloplasty. A four-trocar technique was used. Most patients were discharged home on day 1, with stent removal at 3 weeks. Patency of the ureteropelvic junction was assessed in all patients with mercaptotriglycylglycine Lasix renograms at 1, 3, 6, 9, and 12 months, then every 6 months for 1 year, and then yearly. Results: Each patient underwent a successful procedure without open conversion or transfusion. The average estimated blood loss was 40 ml. The operative time averaged 122 minutes (range 60 to 330) overall. Crossing vessels were present in 30% of the patients and were preserved in all cases. The time for the anastomosis averaged 20 minutes (range 10 to 100). Intraoperatively, no complications occurred. Postoperatively, the average hospital stay was 1.1 days. The stents were removed at an average of 20 days (range 14 to 28) postoperatively. The average follow-up was 11.7 months; at the last follow-up visit, each patient was doing well. Of the 50 patients, 48 underwent one or more renograms, demonstrating stable renal function, improved drainage, and no evidence of recurrent obstruction. Conclusions: Robotic-assisted laparoscopic pyeloplasty is a feasible technique for ureteropelvic junction reconstruction. The procedure provides a minimally invasive alternative with good short-term results.

  13. Robotic single port cholecystectomy (R-LESS-C): experience in 36 patients.

    Science.gov (United States)

    Uras, Cihan; Böler, Deniz Eren; Ergüner, Ilknur; Hamzaoğlu, Ismail

    2014-07-01

    Laparoendoscopic single-site surgery (LESS) has emerged as a result of a search for "pain-less" and "scar-less" surgery. Laparoendoscopic single-site cholecystectomy (LESS-C) is probably the most common application in general surgery, although it harbors certain limitations. It was proposed that the da Vinci Single-Site (Si) robotic system may overcome some of the difficulties experienced during LESS, providing three dimensional views and the ability to work in a right-handed fashion. Thirty-six robotic single port cholecystectomies (R-LESS-C) performed with the da Vinci Si robotic system are evaluated in this paper R-LESS-C performed in 36 patients were reviewed. The data related to the perioperative period (i.e., anesthesia time, operation time, docking time, and console time) was recorded prospectively, whereas the hospitalization period, postoperative visual analogue scale (VAS) pain scores were collected retrospectively. A total number of 36 patients, with a mean age of 40.1 years (21-64 years), underwent R-LESS-C. There were five men and 31 women. The mean anesthesia and operation times were 79.3 minutes (45-130 minutes) and 61.8 minutes (34-110 minutes), respectively. The mean docking time was 9.8 minutes (4-30 minutes) and the mean console time was 24.9 minutes (7-60 minutes). The mean hospital stay was 1.05 days (1-2 days) and the mean pain score (VAS) was 3.6 (2-8) in the first 24 hours. Incisional hernia was recorded in one patient. R-LESS-C can be performed reliably with acceptable operative times and safety. The da Vinci Si robotic system may ease LESS-C. Two issues should be considered for routine use: expensive resources are needed and the incidence of incisional hernia may increase. Copyright © 2013. Published by Elsevier B.V.

  14. Robotic nephroureterectomy: a simplified approach requiring no patient repositioning or robot redocking.

    Science.gov (United States)

    Zargar, Homayoun; Krishnan, Jayram; Autorino, Riccardo; Akca, Oktay; Brandao, Luis Felipe; Laydner, Humberto; Samarasekera, Dinesh; Ko, Oliver; Haber, Georges-Pascal; Kaouk, Jihad H; Stein, Robert J

    2014-10-01

    Robotic technology is increasingly adopted in urologic surgery and a variety of techniques has been described for minimally invasive treatment of upper tract urothelial cancer (UTUC). To describe a simplified surgical technique of robot-assisted nephroureterectomy (RANU) and to report our single-center surgical outcomes. Patients with history of UTUC treated with this modality between April 2010 and August 2013 were included in the analysis. Institutional review board approval was obtained. Informed consent was signed by all patients. A simplified single-step RANU not requiring repositioning or robot redocking. Lymph node dissection was performed selectively. Descriptive analysis of patients' characteristics, perioperative outcomes, histopathology, and short-term follow-up data was performed. The analysis included 31 patients (mean age: 72.4±10.6 yr; mean body mass index: 26.6±5.1kg/m(2)). Twenty-six of 30 tumors (86%) were high grade. Mean tumor size was 3.1±1.8cm. Of the 31 patients, 13 (42%) had pT3 stage disease. One periureteric positive margin was noted in a patient with bulky T3 disease. The mean number of lymph nodes removed was 9.4 (standard deviation: 5.6; range: 3-21). Two of 14 patients (14%) had positive lymph nodes on final histology. No patients required a blood transfusion. Six patients experienced complications postoperatively, with only one being a high grade (Clavien 3b) complication. Median hospital stay was 5 d. Within the follow-up period, seven patients experienced bladder recurrences and four patients developed metastatic disease. Our RANU technique eliminates the need for patient repositioning or robot redocking. This technique can be safely reproduced, with surgical outcomes comparable to other established techniques. We describe a surgical technique using the da Vinci robot for a minimally invasive treatment of patients presenting with upper tract urothelial cancer. This technique can be safely implemented with good surgical outcomes

  15. Robotic Liver Resection: A Case-Matched Comparison.

    Science.gov (United States)

    Kingham, T Peter; Leung, Universe; Kuk, Deborah; Gönen, Mithat; D'Angelica, Michael I; Allen, Peter J; DeMatteo, Ronald P; Laudone, Vincent P; Jarnagin, William R; Fong, Yuman

    2016-06-01

    In recent years, increasingly sophisticated tools have allowed for more complex robotic surgery. Robotic hepatectomy, however, is still in its infancy. Our goals were to examine the adoption of robotic hepatectomy and to compare outcomes between open and robotic liver resections. The robotic hepatectomy experience of 64 patients was compared to a modern case-matched series of 64 open hepatectomy patients at the same center. Matching was according to benign/malignant diagnosis and number of segments resected. Patient data were obtained retrospectively. The main outcomes and measures were operative time, estimated blood loss, conversion rate (robotic to open), Pringle maneuver use, single non-anatomic wedge resection rate, resection margin size, complication rates (infectious, hepatic, pulmonary, cardiac), hospital stay length, ICU stay length, readmission rate, and 90-day mortality rate. Sixty-four robotic hepatectomies were performed in 2010-2014. Forty-one percent were segmental and 34 % were wedge resections. There was a 6 % conversion rate, a 3 % 90-day mortality rate, and an 11 % morbidity rate. Compared to 64 matched patients who underwent open hepatectomy (2004-2012), there was a shorter median OR time (p = 0.02), lower median estimated blood loss (p optimization of outcomes and prospective examination of the economic cost of each approach.

  16. Oncological Outcomes After Robotic Proctectomy for Rectal Cancer: Analysis of a Prospective Database.

    Science.gov (United States)

    Sammour, Tarik; Malakorn, Songphol; Bednarski, Brian K; Kaur, Harmeet; Shin, Ui Sup; Messick, Craig; You, Yi-Qian Nancy; Chang, George J

    2018-03-01

    The aim of this study is to evaluate the oncological outcomes of robotic total mesorectal excision (TME) at an NCI designated cancer center. The effectiveness of laparoscopic TME could not be established, but the robotic-assisted approach may hold some promise, with improved visualization and ergonomics for pelvic dissection. Oncological outcome data is presently lacking. Patients who underwent total mesorectal excision or tumor-specific mesorectal excision for rectal cancer between April 2009 and April 2016 via a robotic approach were identified from a prospective single-institution database. The circumferential resection margin (CRM), distal resection margin, and TME completeness rates were determined. Kaplan-Meier analysis of disease-free survival and overall survival was performed for all patients treated with curative intent. A total of 276 patients underwent robotic proctectomy during the study period. Robotic surgery was performed initially by 1 surgeon with 3 additional surgeons progressively transitioning from open to robotic during the study period with annual increase in the total number of cases performed robotically. Seven patients had involved circumferential resection margins (2.5%), and there were no positive distal or proximal resection margins. One hundred eighty-six patients had TME quality assessed, and only 1 patient (0.5%) had an incomplete TME. Eighty-three patients were followed up for a minimum of 3 years, with a local recurrence rate of 2.4%, and a distant recurrence rate of 16.9%. Five-year disease-free survival on Kaplan-Meier analysis was 82%, and 5-year overall survival was 87%. Robotic proctectomy for rectal cancer can be performed with good short and medium term oncological outcomes in selected patients.

  17. Robotic assisted versus pure laparoscopic surgery of the adrenal glands: a case-control study comparing surgical techniques.

    Science.gov (United States)

    Morelli, Luca; Tartaglia, Dario; Bronzoni, Jessica; Palmeri, Matteo; Guadagni, Simone; Di Franco, Gregorio; Gennai, Andrea; Bianchini, Matteo; Bastiani, Luca; Moglia, Andrea; Ferrari, Vincenzo; Fommei, Enza; Pietrabissa, Andrea; Di Candio, Giulio; Mosca, Franco

    2016-11-01

    The role of the da Vinci Robotic System ® in adrenal gland surgery is not yet well defined. The goal of this study was to compare robotic-assisted surgery with pure laparoscopic surgery in a single center. One hundred and 16 patients underwent minimally invasive adrenalectomies in our department between June 1994 and December 2014, 41 of whom were treated with a robotic-assisted approach (robotic adrenalectomy, RA). Patients who underwent RA were matched according to BMI, age, gender, and nodule dimensions, and compared with 41 patients who had undergone laparoscopic adrenalectomies (LA). Statistical analysis was performed using the Student's t test for independent samples, and the relationship between the operative time and other covariates were evaluated with a multivariable linear regression model. P surgery (p surgery.

  18. Surgeon Design Interface for Patient-Specific Concentric Tube Robots.

    Science.gov (United States)

    Morimoto, Tania K; Greer, Joseph D; Hsieh, Michael H; Okamura, Allison M

    2016-06-01

    Concentric tube robots have potential for use in a wide variety of surgical procedures due to their small size, dexterity, and ability to move in highly curved paths. Unlike most existing clinical robots, the design of these robots can be developed and manufactured on a patient- and procedure-specific basis. The design of concentric tube robots typically requires significant computation and optimization, and it remains unclear how the surgeon should be involved. We propose to use a virtual reality-based design environment for surgeons to easily and intuitively visualize and design a set of concentric tube robots for a specific patient and procedure. In this paper, we describe a novel patient-specific design process in the context of the virtual reality interface. We also show a resulting concentric tube robot design, created by a pediatric urologist to access a kidney stone in a pediatric patient.

  19. Surgical outcomes of robot-assisted rectal cancer surgery using the da Vinci Surgical System: a multi-center pilot Phase II study.

    Science.gov (United States)

    Tsukamoto, Shunsuke; Nishizawa, Yuji; Ochiai, Hiroki; Tsukada, Yuichiro; Sasaki, Takeshi; Shida, Dai; Ito, Masaaki; Kanemitsu, Yukihide

    2017-12-01

    We conducted a multi-center pilot Phase II study to examine the safety of robotic rectal cancer surgery performed using the da Vinci Surgical System during the introduction period of robotic rectal surgery at two institutes based on surgical outcomes. This study was conducted with a prospective, multi-center, single-arm, open-label design to assess the safety and feasibility of robotic surgery for rectal cancer (da Vinci Surgical System). The primary endpoint was the rate of adverse events during and after robotic surgery. The secondary endpoint was the completion rate of robotic surgery. Between April 2014 and July 2016, 50 patients were enrolled in this study. Of these, 10 (20%) had rectosigmoid cancer, 17 (34%) had upper rectal cancer, and 23 (46%) had lower rectal cancer; six underwent high anterior resection, 32 underwent low anterior resection, 11 underwent intersphincteric resection, and one underwent abdominoperineal resection. Pathological stages were Stage 0 in 1 patient, Stage I in 28 patients, Stage II in 7 patients and Stage III in 14 patients. Pathologically complete resection was achieved in all patients. There was no intraoperative organ damage or postoperative mortality. Eight (16%) patients developed complications of all grades, of which 2 (4%) were Grade 3 or higher, including anastomotic leakage (2%) and conversion to open surgery (2%). The present study demonstrates the feasibility and safety of robotic rectal cancer surgery, as reflected by low morbidity and low conversion rates, during the introduction period. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  20. Virtual modeling of robot-assisted manipulations in abdominal surgery.

    Science.gov (United States)

    Berelavichus, Stanislav V; Karmazanovsky, Grigory G; Shirokov, Vadim S; Kubyshkin, Valeriy A; Kriger, Andrey G; Kondratyev, Evgeny V; Zakharova, Olga P

    2012-06-27

    To determine the effectiveness of using multidetector computed tomography (MDCT) data in preoperative planning of robot-assisted surgery. Fourteen patients indicated for surgery underwent MDCT using 64 and 256-slice MDCT. Before the examination, a specially constructed navigation net was placed on the patient's anterior abdominal wall. Processing of MDCT data was performed on a Brilliance Workspace 4 (Philips). Virtual vectors that imitate robotic and assistant ports were placed on the anterior abdominal wall of the 3D model of the patient, considering the individual anatomy of the patient and the technical capabilities of robotic arms. Sites for location of the ports were directed by projection on the roentgen-positive tags of the navigation net. There were no complications observed during surgery or in the post-operative period. We were able to reduce robotic arm interference during surgery. The surgical area was optimal for robotic and assistant manipulators without any need for reinstallation of the trocars. This method allows modeling of the main steps in robot-assisted intervention, optimizing operation of the manipulator and lowering the risk of injuries to internal organs.

  1. Acute myocardial infarctation in patients with critical ischemia underwent lower limb revascularization

    Directory of Open Access Journals (Sweden)

    Esdras Marques Lins

    2013-12-01

    Full Text Available BACKGROUND: Atherosclerosis is the main cause of peripheral artery occlusive disease (PAOD of the lower limbs. Patients with PAOD often also have obstructive atherosclerosis in other arterial sites, mainly the coronary arteries. This means that patients who undergo infrainguinal bypass to treat critical ischemia have a higher risk of AMI. There are, however, few reports in the literature that have assessed this risk properly. OBJECTIVE: The aim of this study was to determine the incidence of acute myocardial infarction in patients who underwent infrainguinal bypass to treat critical ischemia of the lower limbs caused by PAOD. MATERIAL AND METHODS: A total of 64 patients who underwent 82 infrainguinal bypass operations, from February 2011 to July 2012 were studied. All patients had electrocardiograms and troponin I blood assays during the postoperative period (within 72 hours. RESULTS: There were abnormal ECG findings and elevated blood troponin I levels suggestive of AMI in five (6% of the 82 operations performed. All five had conventional surgery. The incidence of AMI as a proportion of the 52 conventional surgery cases was 9.6%. Two patients died. CONCLUSION: There was a 6% AMI incidence among patients who underwent infrainguinal bypass due to PAOD. Considering only cases operated using conventional surgery, the incidence of AMI was 9.6%.

  2. Serum Zn levels in dysphagic patients who underwent endoscopic gastrostomy for long term enteral nutrition

    OpenAIRE

    Adriana Santos, Carla; Fonseca, Jorge; Brito, José; Fernandes, Tânia; Gonçalves, Luísa; Sousa Guerreiro, António

    2014-01-01

    Background and aims: Dysphagic patients who underwent endoscopic gastrostomy (PEG) usually present protein-energy malnutrition, but little is known about micronutrient malnutrition. The aim of the present study was the evaluation of serum zinc in patients who underwent endoscopic gastrostomy and its relationship with serum proteins, whole blood zinc, and the nature of underlying disorder. Methods: From patients that underwent gastrostomy a blood sample was obtained minutes before the procedur...

  3. Laparoscopic and robotic nephroureterectomy

    DEFF Research Database (Denmark)

    Azawi, Nessn H; Berg, Kasper Drimer; Thamsborg, Andreas Key Milan

    2017-01-01

    nephroureterectomy between January 2008 and December 2014 was conducted. Outcome measures were OS and CSM. RESULTS: In total, 298 patients underwent robot-assisted or laparoscopic radical nephroureterectomy with a final histological diagnosis of UTUC. LND was performed in 46 (15.4%). One hundred and seventy...... in the selection of patients undergoing LND. CONCLUSIONS: Five-year OS and CSM are comparable between patients with N1 and N0 MID. This evidence may support the use of the LND procedure in patients with muscle-invasive UTUC....

  4. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2013-01-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  5. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2015-09-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  6. Pancreatic enucleation using the da Vinci robotic surgical system: a report of 26 cases.

    Science.gov (United States)

    Shi, Yusheng; Peng, Chenghong; Shen, Baiyong; Deng, Xiaxing; Jin, Jiabin; Wu, Zhichong; Zhan, Qian; Li, Hongwei

    2016-12-01

    As a tissue-sparing procedure, pancreatic enucleation has become an alternative for benign or borderline pancreatic tumours; it has been proved to be safe and feasible. To date, a large sample size of robotic pancreatic enucleation has not been reported. This study aimed to discuss the clinical evaluation and postoperative complications after robotic pancreatic enucleation and compare it with open surgery. Patients who underwent robotic or open pancreatic enucleation during December 2010-December 2014 at Shanghai Ruijin Hospital, affiliated with the Shanghai Jiaotong University School of Medicine in China, were included. Clinical data were collected and analysed. Patients were divided into an open group and a robotic group: 26 patients underwent robotic pancreatic enucleation, of whom 13 patients were female. The mean age was 51.7 years, the operation time was 125.7 ± 58.8 min, blood loss was 49.4 ± 33.4 ml and mean tumour size was 18.8 ± 7.9 mm; 17 patients underwent open pancreatic enucleation, of whom 11 were female. The mean age was 54.6 ± 17.2 min, blood loss was 198.5 ± 70.7 ml and mean tumour size was 3.5 ± 1.9 cm. Pathology included insulinomas, intrapancreatic mucinous neoplasmas (IPMNs), pancreatic neuro-endocrine tumours (PNETs), solid pseudopapillary tumours (SPTs) and serous cystadenomas (SCAs). Robotic pancreatic enucleations were associated with less trauma, shorter operation time, less blood loss and faster wound recovery compared with open pancreatic enucleation. Pancreatic fistulas (PFs) were the main complication that occurred in the robotic group; infection also occurred in the open group. All patients recovered after effective drainage and the use of somatostatin. The mean follow-up time was 25 months. No recurrence was discovered, and one patient in the open group suffered endocrine insufficiency. Robotic pancreatic enucleation is a safe and effective surgical procedure for pancreatic benign and borderline tumours. It produces less

  7. Robotic prostatectomy: the anesthetist's view for robotic urological surgeries, a prospective study,

    Directory of Open Access Journals (Sweden)

    Menekse Oksar

    2014-09-01

    Full Text Available Background and objectives: Although many features of robotic prostatectomy are similar to those of conventional laparoscopic urological procedures (such as laparoscopic prostatectomy, the procedure is associated with some drawbacks, which include limited intravenous access, relatively long operating time, deep Trendelenburg position, and high intra-abdominal pressure. The primary aim was to describe respiratory and hemodynamic challenges and the complications related to high intra-abdominal pressure and the deep Trendelenburg position in robotic prostatectomy patients. The secondary aim was to reveal safe discharge criteria from the operating room. Methods: Fifty-three patients who underwent robotic prostatectomy between December 2009 and January 2011 were prospectively enrolled. Main outcome measures were non-invasive monitoring, invasive monitoring and blood gas analysis performed at supine (T0, Trendelenburg (T1, Trendelenburg + pneumoperitoneum (T2, Trendelenburg-before desufflation (T3, Trendelenburg (after desufflation (T4, and supine (T5 positions. Results: Fifty-three robotic prostatectomy patients were included in the study. The main clinical challenge in our study group was the choice of ventilation strategy to manage respiratory acidosis, which is detected through end-tidal carbon dioxide pressure and blood gas analysis. Furthermore, the mean arterial pressure remained unchanged, the heart rate decreased significantly and required intervention. The central venous pressure values were also above the normal limits. Conclusion: Respiratory acidosis and "upper airway obstruction-like" clinical symptoms were the main challenges associated with robotic prostatectomy procedures during this study.

  8. Does robotic gait training improve balance in Parkinson's disease? A randomized controlled trial.

    Science.gov (United States)

    Picelli, Alessandro; Melotti, Camilla; Origano, Francesca; Waldner, Andreas; Gimigliano, Raffaele; Smania, Nicola

    2012-09-01

    Treadmill training (with or without robotic assistance) has been reported to improve balance skills in patients with Parkinson's disease (PD). However, its effectiveness on postural instability has been evaluated mainly in patients with mild to moderate PD (Hoehn & Yahr stage ≤3). Patients with more severe disease may benefit from robot-assisted gait training performed by the Gait-Trainer GT1, as a harness supports them with their feet placed on motor-driven footplates. The aim of this study was to determine whether robot-assisted gait training could have a positive influence on postural stability in patients with PD at Hoehn & Yahr stage 3-4. Thirty-four patients with PD at Hoehn & Yahr stage 3-4 were randomly assigned into two groups. All patients received twelve, 40-min treatment sessions, three days/week, for four consecutive weeks. The Robotic Training group (n = 17) underwent robot-assisted gait training, while the Physical Therapy group (n = 17) underwent a training program not specifically aimed at improving postural stability. Patients were evaluated before, immediately after and 1-month post-treatment. Primary outcomes were: Berg Balance scale; Nutt's rating. A significant improvement was found after treatment on the Berg Balance Scale and the Nutt's rating in favor of the Robotic Training group (Berg: 43.44 ± 2.73; Nutt: 1.38 ± 0.50) compared to the Physical Therapy group (Berg: 37.27 ± 5.68; Nutt: 2.07 ± 0.59). All improvements were maintained at the 1-month follow-up evaluation. Robot-assisted gait training may improve postural instability in patients with PD at Hoehn & Yahr stage 3-4. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. An integrated gait rehabilitation training based on Functional Electrical Stimulation cycling and overground robotic exoskeleton in complete spinal cord injury patients: Preliminary results.

    Science.gov (United States)

    Mazzoleni, S; Battini, E; Rustici, A; Stampacchia, G

    2017-07-01

    The aim of this study is to investigate the effects of an integrated gait rehabilitation training based on Functional Electrical Stimulation (FES)-cycling and overground robotic exoskeleton in a group of seven complete spinal cord injury patients on spasticity and patient-robot interaction. They underwent a robot-assisted rehabilitation training based on two phases: n=20 sessions of FES-cycling followed by n= 20 sessions of robot-assisted gait training based on an overground robotic exoskeleton. The following clinical outcome measures were used: Modified Ashworth Scale (MAS), Numerical Rating Scale (NRS) on spasticity, Penn Spasm Frequency Scale (PSFS), Spinal Cord Independence Measure Scale (SCIM), NRS on pain and International Spinal Cord Injury Pain Data Set (ISCI). Clinical outcome measures were assessed before (T0) after (T1) the FES-cycling training and after (T2) the powered overground gait training. The ability to walk when using exoskeleton was assessed by means of 10 Meter Walk Test (10MWT), 6 Minute Walk Test (6MWT), Timed Up and Go test (TUG), standing time, walking time and number of steps. Statistically significant changes were found on the MAS score, NRS-spasticity, 6MWT, TUG, standing time and number of steps. The preliminary results of this study show that an integrated gait rehabilitation training based on FES-cycling and overground robotic exoskeleton in complete SCI patients can provide a significant reduction of spasticity and improvements in terms of patient-robot interaction.

  10. Robot-Assisted Excision of a Pararectal Gastrointestinal Stromal Tumor in a Patient with Previous Ileal Neobladder

    Directory of Open Access Journals (Sweden)

    A. Ploumidis

    2014-01-01

    Full Text Available Gastrointestinal stromal tumors (GISTs are the most frequent mesenchymal tumors of the gastrointestinal tract with surgical resection remaining the cornerstone of therapy. Pararectal lesions are considered to be technically difficult and pose in some cases a challenge. We report, to the best of our knowledge, the first robotic-assisted pararectal GIST excision. A 43-year-old man was referred to our center with pararectal GIST recurrence, despite treatment with targeted therapy. Eleven years ago, he underwent extensive abdominal surgery including cystoprostatectomy with ileal neobladder diversion due to GIST resection in the rectoprostatic space. Robot-assisted surgical resection was successfully performed without the need for temporary colostomy. The postoperative course of the patient was uneventful, and the pathology report confirmed a GIST recurrence with negative surgical margins and pelvic lymph nodes free of any tumor. Robotic-assisted pelvic surgery can be extended to incorporate excision of pararectal GISTs, as a safe, less invasive surgical alternative with promising oncological results and minimal injury to adjacent structures.

  11. Human capital gains associated with robotic assisted laparoscopic pyeloplasty in children compared to open pyeloplasty.

    Science.gov (United States)

    Behan, James W; Kim, Steve S; Dorey, Frederick; De Filippo, Roger E; Chang, Andy Y; Hardy, Brian E; Koh, Chester J

    2011-10-01

    Robotic assisted laparoscopic pyeloplasty is an emerging, minimally invasive alternative to open pyeloplasty in children for ureteropelvic junction obstruction. The procedure is associated with smaller incisions and shorter hospital stays. To our knowledge previous outcome analyses have not included human capital calculations, especially regarding loss of parental workdays. We compared perioperative factors in patients who underwent robotic assisted laparoscopic and open pyeloplasty at a single institution, especially in regard to human capital changes, in an institutional cost analysis. A total of 44 patients 2 years old or older from a single institution underwent robotic assisted (37) or open (7) pyeloplasty from 2008 to 2010. We retrospectively reviewed the charts to collect demographic and perioperative data. The human capital approach was used to calculate parental productivity losses. Patients who underwent robotic assisted laparoscopic pyeloplasty had a significantly shorter average hospital length of stay (1.6 vs 2.8 days, p human capital gains, eg decreased lost parental wages, and lower hospitalization expenses. Future comparative outcome analyses in children should include financial factors such as human capital loss, which can be especially important for families with young children. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. Robot-Assisted Training Early After Cardiac Surgery.

    Science.gov (United States)

    Schoenrath, Felix; Markendorf, Susanne; Brauchlin, Andreas E; Seifert, Burkhardt; Wilhelm, Markus J; Czerny, Martin; Riener, Robert; Falk, Volkmar; Schmied, Christian M

    2015-07-01

    To assess feasibility and safety of a robot-assisted gait therapy with the Lokomat® system in patients early after open heart surgery. Within days after open heart surgery 10 patients were subjected to postoperative Lokomat® training (Intervention group, IG) whereas 20 patients served as controls undergoing standard postoperative physiotherapy (Control group, CG). All patients underwent six-minute walk test and evaluation of the muscular strength of the lower limbs by measuring quadriceps peak force. The primary safety end-point was freedom from any device-related wound healing disturbance. Patients underwent clinical follow-up after one month. Both training methods resulted in an improvement of walking distance (IG [median, interquartile range, p-value]: +119 m, 70-201 m, p = 0.005; CG: 105 m, 57-152.5m, p force (IG left: +5 N, 3.8 7 N, p = 0.005; IG right: +3.5 N, 1.5-8.8 N, p = 0.011; CG left: +5.5 N, 4-9 N, p training were comparable to early postoperative standard in hospital training (median changes in walking distance in percent, p = 0.81; median changes in quadriceps peak force in percent, left: p = 0.97, right p = 0.61). No deep sternal wound infection or any adverse event occurred in the robot-assisted training group. Robot-assisted gait therapy with the Lokomat® system is feasible and safe in patients early after median sternotomy. Results with robot-assisted training were comparable to standard in hospital training. An adapted and combined aerobic and resistance training intervention with augmented feedback may result in benefits in walking distance and lower limb muscle strength (ClinicalTrials.gov number, NCT 02146196). © 2015 Wiley Periodicals, Inc.

  13. Effect of Regional Hospital Competition and Hospital Financial Status on the Use of Robotic-Assisted Surgery.

    Science.gov (United States)

    Wright, Jason D; Tergas, Ana I; Hou, June Y; Burke, William M; Chen, Ling; Hu, Jim C; Neugut, Alfred I; Ananth, Cande V; Hershman, Dawn L

    2016-07-01

    Despite the lack of efficacy data, robotic-assisted surgery has diffused rapidly into practice. Marketing to physicians, hospitals, and patients has been widespread, but how this marketing has contributed to the diffusion of the technology remains unknown. To examine the effect of regional hospital competition and hospital financial status on the use of robotic-assisted surgery for 5 commonly performed procedures. A cohort study of 221 637 patients who underwent radical prostatectomy, total nephrectomy, partial nephrectomy, hysterectomy, or oophorectomy at 1370 hospitals in the United States from January 1, 2010, to December 31, 2011, was conducted. The association between hospital competition, hospital financial status, and performance of robotic-assisted surgery was examined. The association between hospital competition was measured with the Herfindahl-Hirschman Index (HHI), hospital financial status was estimated as operating margin, and performance of robotic-assisted surgery was examined using multivariate mixed-effects regression models. We identified 221 637 patients who underwent one of the procedures of interest. The cohort included 30 345 patients who underwent radical prostatectomy; 20 802, total nephrectomy; 8060, partial nephrectomy; 134 985, hysterectomy; and 27 445, oophorectomy. Robotic-assisted operations were performed for 20 500 (67.6%) radical prostatectomies, 1405 (6.8%) total nephrectomies, 2759 (34.2%) partial nephrectomies, 14 047 (10.4%) hysterectomies, and 1782 (6.5%) oophorectomies. Use of robotic-assisted surgery increased for each procedure from January 2010 through December 2011. For all 5 operations, increased market competition (as measured by the HHI) was associated with increased use of robotic-assisted surgery. For prostatectomy, the risk ratios (95% CIs) for undergoing a robotic-assisted procedure were 2.20 (1.50-3.24) at hospitals in moderately competitive markets and 2.64 (1.84-3.78) for highly competitive markets

  14. Laparoscopic hand-assisted versus robotic-assisted laparoscopic sleeve gastrectomy: experience of 103 consecutive cases.

    Science.gov (United States)

    Kannan, Umashankkar; Ecker, Brett L; Choudhury, Rashikh; Dempsey, Daniel T; Williams, Noel N; Dumon, Kristoffel R

    2016-01-01

    Laparoscopic sleeve gastrectomy has become a stand-alone procedure in the treatment of morbid obesity. There are very few reports on the use of robotic approach in sleeve gastrectomy. The purpose of this retrospective study is to report our early experience of robotic-assisted laparoscopic sleeve gastrectomy (RALSG) using a proctored training model with comparison to an institutional cohort of patients who underwent laparoscopic hand-assisted sleeve gastrectomy (LASG). University hospital. The study included 108 patients who underwent sleeve gastrectomy either via the laparoscopic-assisted or robot-assisted approach during the study period. Of these 108 patients, 62 underwent LASG and 46 underwent RALSG. The console surgeon in the RALSG is a clinical year 4 (CY4) surgery resident. All CY4 surgery residents received targeted simulation training before their rotation. The console surgeon is proctored by the primary surgeon with assistance as needed by the second surgeon. The patients in the robotic and laparoscopic cohorts did not have a statistical difference in their demographic characteristics, preoperative co-morbidities, or complications. The mean operating time did not differ significantly between the 2 cohorts (121 min versus 110 min, P = .07). Patient follow-up in the LSG and RALSG were 91% and 90% at 3 months, 62% and 64% at 6 months, and 60% and 55% at 1 year, respectively. The mean percentage estimated weight loss (EWL%) at 3 months, 6 months, and 1 year was greater in the robotic group but not statistically significant (27 versus 22 at 3 mo [P = .05] and 39 versus 34 at 6 mo [P = .025], 57 versus 48 at 1 yr [P = .09]). There was no mortality in either group. Early results of our experience with RALSG indicate low perioperative complication rates and comparable weight loss with LASG. The concept of a stepwise education model needs further validation with larger studies. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc

  15. Feasibility and safety of early lower limb robot-assisted training in sub-acute stroke patients: a pilot study.

    Science.gov (United States)

    Gandolfi, Marialuisa; Geroin, Christian; Tomelleri, Christopher; Maddalena, Isacco; Kirilova Dimitrova, Eleonora; Picelli, Alessandro; Smania, Nicola; Waldner, Andreas

    2017-12-01

    So far, the development of robotic devices for the early lower limb mobilization in the sub-acute phase after stroke has received limited attention. To explore the feasibility of a newly robotic-stationary gait training in sub-acute stroke patients. To report the training effects on lower limb function and muscle activation. A pilot study. Rehabilitation ward. Two sub-acute stroke inpatients and ten age-matched healthy controls were enrolled. Healthy controls served as normative data. Patients underwent 10 robot-assisted training sessions (20 minutes, 5 days/week) in alternating stepping movements (500 repetitions/session) on a hospital bed in addition to conventional rehabilitation. Feasibility outcome measures were compliance, physiotherapist time, and responses to self-report questionnaires. Efficacy outcomes were bilateral lower limb muscle activation pattern as measured by surface electromyography (sEMG), Motricity Index (MI), Medical Research Council (MRC) grade, and Ashworth Scale (AS) scores before and after training. No adverse events occurred. No significant differences in sEMG activity between patients and healthy controls were observed. Post-training improvement in MI and MRC scores, but no significant changes in AS scores, were recorded. Post-treatment sEMG analysis of muscle activation patterns showed a significant delay in rectus femoris offset (P=0.02) and prolonged duration of biceps femoris (P=0.04) compared to pretreatment. The robot-assisted training with our device was feasible and safe. It induced physiological muscle activations pattern in both stroke patients and healthy controls. Full-scale studies are needed to explore its potential role in post-stroke recovery. This robotic device may enrich early rehabilitation in subacute stroke patients by inducing physiological muscle activation patterns. Future studies are warranted to evaluate its effects on promoting restorative mechanisms involved in lower limb recovery after stroke.

  16. Comparison of robot-assisted versus conventional laparoscopic transperitoneal pyeloplasty for patients with ureteropelvic junction obstruction: a single-center study.

    Science.gov (United States)

    Bird, Vincent G; Leveillee, Raymond J; Eldefrawy, Ahmed; Bracho, Jorge; Aziz, Mohammed S

    2011-03-01

    To compare conventional laparoscopic pyeloplasty (C-LPP) and robotic-assisted laparoscopic pyeloplasty (RA-LPP), which are both used for correction of ureteropelvic junction obstruction. Robotic assistance may further expedite dissection and reconstruction; however it is unclear whether this has an impact on results. Between 1999 and 2009, 172 conventional or robotic-assisted transperitoneal laparoscopic pyeloplasties were performed by 2 surgeons. Data were obtained from our prospective database, patient charts, and radiographic reports. Statistical analysis was performed for the groups. A total of 98 patients underwent R-LPP, and 74 underwent C-LPP. Mean age, body mass index, and gender distribution were similar for the groups. Of the patients, 22 (12.8%) had secondary ureteropelvic junction obstruction. Operative time in minutes was 189.3 ± 62 for RA-LPP, and 186.6 ± 69 for C-LPP (P = .69) respectively. Intraoperative and postoperative complication rates for RA-LPP and C-LPP were 1%, 5.1% and 0, 2.7% (P = .83 and .85) respectively. There was no significant difference in mean suturing time: 48.3 ± 30 and 60 ± 46 (P = .30) for RA-LPP and C-LPP, respectively. Long-term follow up (minimum 6 months; available for 136 patients) showed 93.4% and 95% radiographic success rate based upon diuretic scintirenography for RA-LPP and C-LPP respectively. Operative time, perioperative outcome and success rates are similar for C-LPP and RA-LPP. Mean suturing time for RA-LPP was shorter; however, there was no significant time difference in total operative time. Complications for both procedures are infrequent. Success rates, as measured by diuretic scintirenography, are high for the 2 procedures. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Comparison of Voice Quality Between Patients Who Underwent Inferior Turbinoplasty or Radiofrequency Cauterization.

    Science.gov (United States)

    Göker, Ayşe Enise; Aydoğdu, İmran; Saltürk, Ziya; Berkiten, Güler; Atar, Yavuz; Kumral, Tolgar Lütfi; Uyar, Yavuz

    2017-01-01

    The aim of this study was to analyze and compare the vocal quality in patients who underwent either submucosal turbinectomy or radiofrequency cauterization. In this study, we enrolled 60 patients diagnosed with inferior concha hypertrophy. These patients were divided into two groups by using computer program "Research Randomizer." Of the 60 patients, 30 underwent submucosal inferior turbinoplasty and 30 underwent radiofrequency cauterization. The control group was composed of 30 healthy adults with no nasal or upper aerodigestive system pathology. The patients were checked at weeks 1, 2, and 4. Voice records were taken before the procedure and at week 4 postprocedure. The mean age of patients in the inferior turbinoplasty group was 29.4 years (range: 19-42 years); in the radiofrequency group, it was 30.30 years (range: 18-50 years). There was no statistical difference in age between groups. In the inferior turbinoplasty group, there were 16 male and 14 female patients, and in the radiofrequency group, there were 13 male and 17 female patients. There was no significant difference in the number of males and females between groups. Voice professionals, especially singers, actors, and actresses, should be informed about possible voice changes before undergoing endonasal surgery because these individuals are more sensitive to changes in resonance organs. We believe that voice quality should be regarded as a highly important parameter when measuring the success of endonasal surgery. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  18. Efficacy and durability of robotic Heller myotomy for achalasia: patient symptoms and satisfaction at long-term follow-up.

    Science.gov (United States)

    Perry, Kyle A; Kanji, Aliyah; Drosdeck, Joseph M; Linn, John G; Chan, Anthony; Muscarella, Peter; Melvin, W Scott

    2014-11-01

    Laparoscopic Heller myotomy (LHM) has become the standard treatment for achalasia in the USA. Robot-assisted Heller myotomy (RHM) has emerged as an alternative approach due to improved visualization and fine motor control, but long-term follow-up studies have not been reported. We sought to report the long-term outcomes of RHM and compare them to those of LHM. A retrospective cohort study was performed for patients who underwent laparoscopic or RHM between 1995 and 2006. Long-term follow-up was performed via mail or telephone questionnaire. The primary outcome measure was durable relief of dysphagia without need for further intervention. Secondary outcomes included gastroesophageal reflux symptoms, disease-specific quality of life, and patient satisfaction with their operation. Seventy-five patients underwent laparoscopic (n = 19) or robotic (n = 56) myotomy during the study period. Long-term follow-up was obtained in 53 (71 %) patients with a median interval of 9 years. RHM was associated with a decreased mucosal injury rate (0 vs. 16 %, p = 0.01) and median hospital stay (1 vs. 2 days, p myotomy and 80 % after laparoscopic myotomy (p = 0.27). Overall, 95 % of patients were satisfied with their operation, and 91 % would choose surgery again given the benefit of hindsight. There is a dearth of long-term follow-up data to support the effectiveness of RHM. This study demonstrates durable dysphagia relief in the vast majority of patients with a high degree of patient satisfaction and a low rate of esophageal mucosal injury. While a significant proportion of patients report reflux symptoms, these symptoms are well controlled with medical acid suppression.

  19. Outcome of Patients Underwent Emergency Department Thoracotomy and Its Predictive Factors

    Directory of Open Access Journals (Sweden)

    Shahram Paydar

    2014-08-01

    Full Text Available Introduction: Emergency department thoracotomy (EDT may serve as the last survival chance for patients who arrive at hospital in extremis. It is considered as an effective tool for improvement of traumatic patients’ outcome. The present study was done with the goal of assessing the outcome of patients who underwent EDT and its predictive factors. Methods: In the present study, medical charts of 50 retrospective and 8 prospective cases underwent emergency department thoracotomy (EDT were reviewed during November 2011 to June 2013. Comparisons between survived and died patients were performed by Mann-Whitney U test and the predictive factors of EDT outcome were measured using multivariate logistic regression analysis. P < 0.05 considered statistically significant. Results: Fifty eight cases of EDT were enrolled (86.2% male. The mean age of patients was 43.27±19.85 years with the range of 18-85. The mean time duration of CPR was recorded as 37.12±12.49 minutes. Eleven cases (19% were alive to be transported to OR (defined as ED survived. The mean time of survival in ED survived patients was 223.5±450.8 hours. More than 24 hours survival rate (late survived was 6.9% (4 cases. Only one case (1.7% survived to discharge from hospital (mortality rate=98.3%. There were only a significant relation between ED survival and SBP, GCS, CPR duration, and chest trauma (p=0.04. The results demonstrated that initial SBP lower than 80 mmHg (OR=1.03, 95% CI: 1.001-1.05, p=0.04 and presence of chest trauma (OR=2.6, 95% CI: 1.75-3.16, p=0.02 were independent predictive factors of EDT mortality. Conclusion: The findings of the present study showed that the survival rate of trauma patients underwent EDT was 1.7%. In addition, it was defined that falling systolic blood pressure below 80 mmHg and blunt trauma of chest are independent factors that along with poor outcome.

  20. Influence of facial feedback during a cooperative human-robot task in schizophrenia.

    Science.gov (United States)

    Cohen, Laura; Khoramshahi, Mahdi; Salesse, Robin N; Bortolon, Catherine; Słowiński, Piotr; Zhai, Chao; Tsaneva-Atanasova, Krasimira; Di Bernardo, Mario; Capdevielle, Delphine; Marin, Ludovic; Schmidt, Richard C; Bardy, Benoit G; Billard, Aude; Raffard, Stéphane

    2017-11-03

    Rapid progress in the area of humanoid robots offers tremendous possibilities for investigating and improving social competences in people with social deficits, but remains yet unexplored in schizophrenia. In this study, we examined the influence of social feedbacks elicited by a humanoid robot on motor coordination during a human-robot interaction. Twenty-two schizophrenia patients and twenty-two matched healthy controls underwent a collaborative motor synchrony task with the iCub humanoid robot. Results revealed that positive social feedback had a facilitatory effect on motor coordination in the control participants compared to non-social positive feedback. This facilitatory effect was not present in schizophrenia patients, whose social-motor coordination was similarly impaired in social and non-social feedback conditions. Furthermore, patients' cognitive flexibility impairment and antipsychotic dosing were negatively correlated with patients' ability to synchronize hand movements with iCub. Overall, our findings reveal that patients have marked difficulties to exploit facial social cues elicited by a humanoid robot to modulate their motor coordination during human-robot interaction, partly accounted for by cognitive deficits and medication. This study opens new perspectives for comprehension of social deficits in this mental disorder.

  1. No differences in short-term morbidity and mortality after robot-assisted laparoscopic versus laparoscopic resection for colonic cancer

    DEFF Research Database (Denmark)

    Helvind, Neel Maria; Eriksen, Jens Ravn; Mogensen, Anders Skibsted

    2013-01-01

    BACKGROUND: Robot-assisted laparoscopy has been reported to be a safe and feasible alternative to traditional laparoscopy. The aim of this study was to compare short-term results in patients with colonic cancer who underwent robot-assisted laparoscopic colonic resection (RC) or laparoscopic colonic...... journals. Biochemical markers [C-reactive protein (CRP), hemoglobin, white blood cell count, and thrombocyte count] were recorded before surgery and for the first 3 days after surgery. RESULTS: A total of 101 patients underwent RC and 162 patients underwent LC. There were no significant differences...... in the rate of conversion to open surgery, number of permanent enterostomies, number of intraoperative complications, level of postoperative cellular stress response, number of postoperative complications, length of postoperative hospital stay, or 30-day mortality between the two groups...

  2. Initial experience with robotic pancreatic surgery in Singapore: single institution experience with 30 consecutive cases.

    Science.gov (United States)

    Goh, Brian K P; Low, Tze-Yi; Lee, Ser-Yee; Chan, Chung-Yip; Chung, Alexander Y F; Ooi, London L P J

    2018-05-24

    Presently, the worldwide experience with robotic pancreatic surgery (RPS) is increasing although widespread adoption remains limited. In this study, we report our initial experience with RPS. This is a retrospective review of a single institution prospective database of 72 consecutive robotic hepatopancreatobiliary surgeries performed between 2013 and 2017. Of these, 30 patients who underwent RPS were included in this study of which 25 were performed by a single surgeon. The most common procedure was robotic distal pancreatectomy (RDP) which was performed in 20 patients. This included eight subtotal pancreatectomies, two extended pancreatecto-splenectomies (en bloc gastric resection) and 10 spleen-saving-RDP. Splenic preservation was successful in 10/11 attempted spleen-saving-RDP. Eight patients underwent pancreaticoduodenectomies (five hybrid with open reconstruction), one patient underwent a modified Puestow procedure and one enucleation of uncinate tumour. Four patients had extended resections including two RDP with gastric resection and two pancreaticoduodenectomies with vascular resection. There was one (3.3%) open conversion and seven (23.3%) major (>Grade II) morbidities. Overall, there were four (13.3%) clinically significant (Grade B) pancreatic fistulas of which three required percutaneous drainage. These occurred after three RDP and one robotic enucleation. There was one reoperation for port-site hernia and no 30-day/in-hospital mortalities. The median post-operative stay was 6.5 (range: 3-36) days and there were six (20%) 30-day readmissions. Our initial experience showed that RPS can be adopted safely with a low open conversion rate for a wide variety of procedures including pancreaticoduodenectomy. © 2018 Royal Australasian College of Surgeons.

  3. [A Distal Bile Duct Carcinoma Patient Who Underwent Surgical Resection for Liver Metastasis].

    Science.gov (United States)

    Komiyama, Sosuke; Izumiya, Yasuhito; Kimura, Yu; Nakashima, Shingo; Kin, Syuichi; Kawakami, Sadao

    2018-03-01

    A 70-year-old man with distal bile duct carcinoma underwent a subtotal stomach-preserving pancreaticoduodenectomy without adjuvant chemotherapy. One and a half years after the surgery, elevated levels of serum SPan-1(38.1 U/mL)were observed and CT scans demonstrated a solitary metastasis, 25mm in size, in segment 8 of the liver. The patient received 2 courses of gemcitabine-cisplatin combination chemotherapy. No new lesions were detected after chemotherapy and the patient underwent a partial liver resection of segment 8. The pathological examination revealed a metachronous distant metastasis originating from the bile duct carcinoma. Subsequently, the patient received S-1 adjuvant chemotherapy for 6 months. Following completion of all therapies, the patient survived without tumor recurrence for 3 years and 10 months after the initial operation. Thus, surgical interventions might be effective in improving prognosis among selected patients with postoperative liver metastasis of bile duct carcinoma.

  4. Effect of using pump on postoperative pleural effusion in the patients that underwent CABG

    Directory of Open Access Journals (Sweden)

    Mehmet Özülkü

    2015-08-01

    Full Text Available Abstract Objective: The present study investigated effect of using pump on postoperative pleural effusion in patients who underwent coronary artery bypass grafting. Methods: A total of 256 patients who underwent isolated coronary artery bypass grafting surgery in the Cardiovascular Surgery clinic were enrolled in the study. Jostra-Cobe (Model 043213 105, VLC 865, Sweden heart-lung machine was used in on-pump coronary artery bypass grafting. Off-pump coronary artery bypass grafting was performed using Octopus and Starfish. Proximal anastomoses to the aorta in both on-pump and off-pump techniques were performed by side clamps. The patients were discharged from the hospital between postoperative day 6 and day 11. Results: The incidence of postoperative right pleural effusion and bilateral pleural effusion was found to be higher as a count in Group 1 (on-pump as compared to Group 2 (off-pump. But the difference was not statistically significant [P>0.05 for right pleural effusion (P=0.893, P>0.05 for bilateral pleural effusion (P=0.780]. Left pleural effusion was encountered to be lower in Group 2 (off-pump. The difference was found to be statistically significant (P<0.05, P=0.006. Conclusion: Under the light of these results, it can be said that left pleural effusion is less prevalent in the patients that underwent off-pump coronary artery bypass grafting when compared to the patients that underwent on-pump coronary artery bypass grafting.

  5. Robot-assisted training for heart failure patients - a small pilot study.

    Science.gov (United States)

    Schoenrath, Felix; Markendorf, Susanne; Brauchlin, Andreas Emil; Frank, Michelle; Wilhelm, Markus Johannes; Saleh, Lanja; Riener, Robert; Schmied, Christian Marc; Falk, Volkmar

    2015-12-01

    The objective of this study was assess robot-assisted gait therapy with the Lokomat® system in heart failure patients. Patients (n = 5) with stable heart failure and a left ventricular ejection fraction of less than 45% completed a four-week aerobic training period with three trainings per week and an integrated dynamic resistance training of the lower limbs. Patients underwent testing of cardiac and inflammatory biomarkers. A cardiopulmonary exercise test, a quality of life score and an evaluation of the muscular strength by measuring the peak quadriceps force was performed. No adverse events occurred. The combined training resulted in an improvement in peak work rate (range: 6% to 36%) and peak quadriceps force (range: 3% to 80%) in all participants. Peak oxygen consumption (range: –3% to + 61%) increased in three, and oxygen pulse (range: –7% to + 44%) in four of five patients. The quality of life assessment indicated better well-being in all participants. NT-ProBNP (+233 to –733 ng/ml) and the inflammatory biomarkers (hsCRP and IL6) decreased in four of five patients (IL 6: +0.5 to –2 mg/l, hsCRP: +0.2 to –6.5 mg/l). Robot-assisted gait therapy with the Lokomat® System is feasible in heart failure patients and was safe in this trial. The combined aerobic and resistance training intervention with augmented feedback resulted in benefits in exercise capacity, muscle strength and quality of life, as well as an improvement of cardiac (NT-ProBNP) and inflammatory (IL6, hsCRP) biomarkers. Results can only be considered as preliminary and need further validation in larger studies. (ClinicalTrials.gov number, NCT 02146196)

  6. Robot-assisted laparoscopic (RAL) procedures in general surgery.

    Science.gov (United States)

    Alimoglu, Orhan; Sagiroglu, Julide; Atak, Ibrahim; Kilic, Ali; Eren, Tunc; Caliskan, Mujgan; Bas, Gurhan

    2016-09-01

    Robotics was introduced in clinical practice more than two decades ago, and it has gained remarkable popularity for a wide variety of laparoscopic procedures. We report our results of robot-assisted laparoscopic surgery (RALS) in the most commonly applied general surgical procedures. Ninety seven patients underwent RALS from 2009 to 2012. Indications for RALS were cholelithiasis, gastric carcinoma, splenic tumors, colorectal carcinoma, benign colorectal diseases, non-toxic nodular goiter and incisional hernia. Records of patients were analyzed for demographic features, intraoperative and postoperative complications and conversion to open surgery. Forty six female and 51 male patients were operated and mean age was 58,4 (range: 25-88). Ninety three out of 97 procedures (96%) were completed robotically, 4 were converted to open surgery and there were 15 postoperative complications. There was no mortality. Wide variety of procedures of general surgery can be managed safely and effectively by RALS. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Postoperative rhabdomyolysis following robotic renal and adrenal surgery: a cautionary tale of compounding risk factors.

    Science.gov (United States)

    Terry, Russell S; Gerke, Travis; Mason, James B; Sorensen, Matthew D; Joseph, Jason P; Dahm, Philipp; Su, Li-Ming

    2015-09-01

    This study aimed at reviewing a contemporary series of patients who underwent robotic renal and adrenal surgery by a single surgeon at a tertiary referral academic medical center over a 6-year period, specifically focusing on the unique and serious complication of post-operative rhabdomyolysis of the dependent lower extremity. The cases of 315 consecutive patients who underwent robotic upper tract surgery over a 6-year period from August 2008 to June 2014 using a standardized patient positioning were reviewed and analyzed for patient characteristics and surgical variables that may be associated with the development of post-operative rhabdomyolysis. The incidence of post-operative rhabdomyolysis in our series was 3/315 (0.95%). All three affected patients had undergone robotic nephroureterectomy. Those patients who developed rhabdomyolysis had significantly higher mean Body Mass Index, Charlson Comorbidity Index, and median length of stay than those who did not. The mean OR time in the rhabdomyolysis group was noted to be 52 min longer than the non-rhabdomyolysis group, though this value did not reach statistical significance. Given the trends of increasing obesity in the United States and abroad as well as the continued rise in robotic upper tract urologic surgeries, urologists need to be increasingly vigilant for recognizing the risk factors and early treatment of the unique complication of post-operative rhabdomyolysis.

  8. Robot-assisted gait training for stroke patients: current state of the art and perspectives of robotics.

    Science.gov (United States)

    Morone, Giovanni; Paolucci, Stefano; Cherubini, Andrea; De Angelis, Domenico; Venturiero, Vincenzo; Coiro, Paola; Iosa, Marco

    2017-01-01

    In this review, we give a brief outline of robot-mediated gait training for stroke patients, as an important emerging field in rehabilitation. Technological innovations are allowing rehabilitation to move toward more integrated processes, with improved efficiency and less long-term impairments. In particular, robot-mediated neurorehabilitation is a rapidly advancing field, which uses robotic systems to define new methods for treating neurological injuries, especially stroke. The use of robots in gait training can enhance rehabilitation, but it needs to be used according to well-defined neuroscientific principles. The field of robot-mediated neurorehabilitation brings challenges to both bioengineering and clinical practice. This article reviews the state of the art (including commercially available systems) and perspectives of robotics in poststroke rehabilitation for walking recovery. A critical revision, including the problems at stake regarding robotic clinical use, is also presented.

  9. [Short-term efficacy of da Vinci robotic surgical system on rectal cancer in 101 patients].

    Science.gov (United States)

    Zeng, Dong-Zhu; Shi, Yan; Lei, Xiao; Tang, Bo; Hao, Ying-Xue; Luo, Hua-Xing; Lan, Yuan-Zhi; Yu, Pei-Wu

    2013-05-01

    To investigate the feasibility and safety of da Vinci robotic surgical system in rectal cancer radical operation, and to summarize its short-term efficacy and clinical experience. Data of 101 cases undergoing da Vinci robotic surgical system for rectal cancer radical operation from March 2010 to September 2012 were retrospectively analyzed. Evaluation was focused on operative procedure, complication, recovery and pathology. All the 101 cases underwent operation successfully and safely without conversion to open procedure. Rectal cancer radical operation with da Vinci robotic surgical system included 73 low anterior resections and 28 abdominoperineal resections. The average operative time was (210.3±47.2) min. The average blood lose was (60.5±28.7) ml without transfusion. Lymphadenectomy harvest was 17.3±5.4. Passage of first flatus was (2.7±0.7) d. Distal margin was (5.3±2.3) cm without residual cancer cells. The complication rate was 6.9%, including anastomotic leakage(n=2), perineum incision infection(n=2), pulmonary infection (n=2), urinary retention (n=1). There was no postoperative death. The mean follow-up time was(12.9±8.0) months. No local recurrence was found except 2 cases with distant metastasis. Application of da Vinci robotic surgical system in rectal cancer radical operation is safe and patients recover quickly The short-term efficacy is satisfactory.

  10. Robot-assisted radical prostatectomy: Multiparametric MR imaging-directed intraoperative frozen-section analysis to reduce the rate of positive surgical margins.

    Science.gov (United States)

    Petralia, Giuseppe; Musi, Gennaro; Padhani, Anwar R; Summers, Paul; Renne, Giuseppe; Alessi, Sarah; Raimondi, Sara; Matei, Deliu V; Renne, Salvatore L; Jereczek-Fossa, Barbara A; De Cobelli, Ottavio; Bellomi, Massimo

    2015-02-01

    To investigate whether use of multiparametric magnetic resonance (MR) imaging-directed intraoperative frozen-section (IFS) analysis during nerve-sparing robot-assisted radical prostatectomy reduces the rate of positive surgical margins. This retrospective analysis of prospectively acquired data was approved by an institutional ethics committee, and the requirement for informed consent was waived. Data were reviewed for 134 patients who underwent preoperative multiparametric MR imaging (T2 weighted, diffusion weighted, and dynamic contrast-material enhanced) and nerve-sparing robot-assisted radical prostatectomy, during which IFS analysis was used, and secondary resections were performed when IFS results were positive for cancer. Control patients (n = 134) matched for age, prostate-specific antigen level, and stage were selected from a pool of 322 patients who underwent nerve-sparing robot-assisted radical prostatectomy without multiparametric MR imaging and IFS analysis. Rates of positive surgical margins were compared by means of the McNemar test, and a multivariate conditional logistic regression model was used to estimate the odds ratio of positive surgical margins for patients who underwent MR imaging and IFS analysis compared with control subjects. Eighteen patients who underwent MR imaging and IFS analysis underwent secondary resections, and 13 of these patients were found to have negative surgical margins at final pathologic examination. Positive surgical margins were found less frequently in the patients who underwent MR imaging and IFS analysis than in control patients (7.5% vs 18.7%, P = .01). When the differences in risk factors are taken into account, patients who underwent MR imaging and IFS had one-seventh the risk of having positive surgical margins relative to control patients (adjusted odds ratio: 0.15; 95% confidence interval: 0.04, 0.61). The significantly lower rate of positive surgical margins compared with that in control patients provides

  11. How to prepare the patient for robotic surgery: before and during the operation.

    Science.gov (United States)

    Lim, Peter C; Kang, Elizabeth

    2017-11-01

    Robotic surgery in the treatment of gynecologic diseases continues to evolve and has become accepted over the last decade. The advantages of robotic-assisted laparoscopic surgery over conventional laparoscopy are three-dimensional camera vision, superior precision and dexterity with EndoWristed instruments, elimination of operator tremor, and decreased surgeon fatigue. The drawbacks of the technology are bulkiness and lack of tactile feedback. As with other surgical platforms, the limitations of robotic surgery must be understood. Patient selection and the types of surgical procedures that can be performed through the robotic surgical platform are critical to the success of robotic surgery. First, patient selection and the indication for gynecologic disease should be considered. Discussion with the patient regarding the benefits and potential risks of robotic surgery and of complications and alternative treatments is mandatory, followed by patient's signature indicating informed consent. Appropriate preoperative evaluation-including laboratory and imaging tests-and bowel cleansing should be considered depending upon the type of robotic-assisted procedure. Unlike other surgical procedures, robotic surgery is equipment-intensive and requires an appropriate surgical suite to accommodate the patient side cart, the vision system, and the surgeon's console. Surgical personnel must be properly trained with the robotics technology. Several factors must be considered to perform a successful robotic-assisted surgery: the indication and type of surgical procedure, the surgical platform, patient position and the degree of Trendelenburg, proper port placement configuration, and appropriate instrumentation. These factors that must be considered so that patients can be appropriately prepared before and during the operation are described. Copyright © 2017. Published by Elsevier Ltd.

  12. Robotic tilt table reduces the occurrence of orthostatic hypotension over time in vegetative states.

    Science.gov (United States)

    Taveggia, Giovanni; Ragusa, Ivana; Trani, Vincenzo; Cuva, Daniele; Angeretti, Cristina; Fontanella, Marco; Panciani, Pier Paolo; Borboni, Alberto

    2015-06-01

    The aim of this study is to evaluate the effects of verticalization with or without combined movement of the lower limbs in patients in a vegetative state or a minimally conscious state. In particular, we aimed to study whether, in the group with combined movement, there was better tolerance to verticalization. This was a randomized trial conducted in a neurorehabilitation hospital. Twelve patients with vegetative state and minimally conscious state 3-18 months after acute acquired brain injuries were included. Patients were randomized into A and B treatment groups. Study group A underwent verticalization with a tilt table at 65° and movimentation of the lower limbs with a robotic system for 30 min three times a week for 24 sessions. Control group B underwent the same rehabilitation treatment, with a robotic verticalization system, but an inactive lower-limb movement system. Systolic and diastolic blood pressure and heart rate were determined. Robotic movement of the lower limbs can reduce the occurrence of orthostatic hypotension in hemodynamically unstable patients. Despite the small number of patients involved (only eight patients completed the trial), our results indicate that blood pressures and heart rate can be stabilized better (with) by treatment with passive leg movements in hemodynamically unstable patients.

  13. Impact of robotic surgery on sexual and urinary functions after fully robotic nerve-sparing total mesorectal excision for rectal cancer.

    Science.gov (United States)

    Luca, Fabrizio; Valvo, Manuela; Ghezzi, Tiago Leal; Zuccaro, Massimiliano; Cenciarelli, Sabina; Trovato, Cristina; Sonzogni, Angelica; Biffi, Roberto

    2013-04-01

    Urinary and sexual dysfunctions are recognized complications of rectal cancer surgery. Their incidence after robotic surgery is as yet unknown. The aim of this study was to prospectively evaluate the impact of robotic surgery for rectal cancer on sexual and urinary functions in male and female patients. From April 2008 to December 2010, 74 patients undergoing fully robotic resection for rectal cancer were prospectively included in the study. Urinary and sexual dysfunctions affecting quality of life were assessed with specific self-administered questionnaires in all patients undergoing robotic total mesorectal excision (RTME). Results were calculated with validated scoring systems and statistically analyzed. The analyses of the questionnaires completed by the 74 patients who underwent RTME showed that sexual function and general sexual satisfaction decreased significantly 1 month after intervention: 19.1 ± 8.7 versus 11.9 ± 10.2 (P surgery, the values were comparable to those measured before surgery. Concerning urinary function, the grade of incontinence measured 1 year after the intervention was unchanged for both sexes. RTME allows for preservation of urinary and sexual functions. This is probably due to the superior movements of the wristed instruments that facilitate fine dissection, coupled with a stable and magnified view that helps in recognizing the inferior hypogastric plexus.

  14. Hand robotics rehabilitation: feasibility and preliminary results of a robotic treatment in patients with hemiparesis.

    Science.gov (United States)

    Sale, Patrizio; Lombardi, Valentina; Franceschini, Marco

    2012-01-01

    Background. No strongly clinical evidence about the use of hand robot-assisted therapy in stroke patients was demonstrated. This preliminary observer study was aimed at evaluating the efficacy of intensive robot-assisted therapy in hand function recovery, in the early phase after a stroke onset. Methods. Seven acute ischemic stroke patients at their first-ever stroke were enrolled. Treatment was performed using Amadeo robotic system (Tyromotion GmbH Graz, Austria). Each participant received, in addition to inpatients standard rehabilitative treatment, 20 sessions of robotic treatment for 4 consecutive weeks (5 days/week). Each session lasted for 40 minutes. The exercises were carried out as follows: passive modality (5 minutes), passive/plus modality (5 minutes), assisted therapy (10 minutes), and balloon (10 minutes). The following impairment and functional evaluations, Fugl-Meyer Scale (FM), Medical Research Council Scale for Muscle Strength (hand flexor and extensor muscles) (MRC), Motricity Index (MI), and modified Ashworth Scale for wrist and hand muscles (AS), were performed at the beginning (T0), after 10 sessions (T1), and at the end of the treatment (T2). The strength hand flexion and extension performed by Robot were assessed at T0 and T2. The Barthel Index and COMP (performance and satisfaction subscale) were assessed at T0 and T2. Results. Clinical improvements were found in all patients. No dropouts were recorded during the treatment and all subjects fulfilled the protocol. Evidence of a significant improvement was demonstrated by the Friedman test for the MRC (P hand motor recovery in acute stroke patients. The simplicity of the treatment, the lack of side effects, and the first positive results in acute stroke patients support the recommendations to extend the clinical trial of this treatment, in association with physiotherapy and/or occupational therapy.

  15. Arm reduced robotic-assisted laparoscopic hysterectomy with transvaginal cuff closure.

    Science.gov (United States)

    Bodur, Serkan; Dede, Murat; Fidan, Ulas; Firatligil, Burcin F; Ulubay, Mustafa; Ozturk, Mustafa; Yenen, Mufit C

    2017-09-01

    The use of robotics for benign etiology in gynecology has not proven to be more beneficial when compared to traditional laparoscopy. The major concern regarding robotic hysterectomy stems from its high cost. To evaluate the clinical utility and effectiveness of one-arm reduced robotic-assisted laparoscopic hysterectomy as a cost-effective surgical option for total robotic hysterectomy. A sample population of 54 women who underwent robotic-assisted laparoscopic surgery for benign gynecologic indications was evaluated, and two groups were identified: (1) the two-armed robotic-assisted laparoscopic surgery group (n = 38 patients), and (2) the three-armed robotic-assisted laparoscopic surgery group (n = 16 patients). An increased cost was observed when three-armed robotic surgery was employed for benign gynecologic surgery (p < 0.001). The cost reduction observed in the study group was primarily derived from one robotic arm reduction and vaginal closure of the cuff. This cost reduction was achieved without an increase in complication rates or undesirable postoperative outcomes. An estimated profit between $399.5 and $421.5 was made for each patient depending on the suture material chosen for cuff closure. Two-armed surgery resulted in an 18.6% reduction in procedure-specific costs for robotic hysterectomy. Two-armed robotic-assisted laparoscopic hysterectomy appears to be a cost-effective solution for robotic gynecologic surgery. This surgical solution can be performed as effectively as classical three-armed robotic hysterectomies for benign indications without the risk of increased surgical-related morbidities. This approach has the potential to be a widely preferred surgical approach in medical communities where cost reduction is one of the primary determinants of surgery type.

  16. Incidence of Bradycardia and Outcomes of Patients Who Underwent Orbital Atherectomy Without a Temporary Pacemaker.

    Science.gov (United States)

    Lee, Michael S; Nguyen, Heajung; Shlofmitz, Richard

    2017-02-01

    We analyzed the incidence of bradycardia and the safety of patients with severely calcified coronary lesions who underwent orbital atherectomy without the insertion of a temporary pacemaker. The presence of severely calcified coronary lesions can increase the complexity of percutaneous coronary intervention due to the difficulty in advancing and optimally expanding the stent. High-pressure inflations to predilate calcified lesions may cause angiographic complications like perforation and dissection. Suboptimal stent expansion is associated with stent thrombosis and restenosis. Orbital atherectomy safely and effectively modifies calcified plaque to facilitate optimal stent expansion. The incidence of bradycardia in orbital atherectomy is unknown. Fifty consecutive patients underwent orbital atherectomy from February 2014 to September 2016 at our institution, none of whom underwent insertion of a temporary pacemaker. The final analysis included 47 patients in this retrospective study as 3 patients were excluded because of permanent pacemaker implantation. The primary endpoint was significant bradycardia, defined as bradycardia requiring emergent pacemaker placement or a heart rate pacemaker appears to be safe.

  17. Impact of Polypharmacy on Adherence to Evidence-Based Medication in Patients who Underwent Percutaneous Coronary Intervention.

    Science.gov (United States)

    Mohammed, Shaban; Arabi, Abdulrahaman; El-Menyar, Ayman; Abdulkarim, Sabir; AlJundi, Amer; Alqahtani, Awad; Arafa, Salah; Al Suwaidi, Jassim

    2016-01-01

    The primary objective of this study was to evaluate the impact of polypharmacy on primary and secondary adherence to evidence-based medication (EBM) and to measure factors associated with non-adherence among patients who underwent percutaneous coronary intervention (PCI). We conducted a retrospective analysis for patients who underwent PCI at a tertiary cardiac care hospital in Qatar. Patients who had polypharmacy (defined as ≥6 medications) were compared with those who had no polypharmacy at hospital discharge in terms of primary and secondary adherence to dual antiplatelet therapy (DAPT), beta-blockers (BB), angiotensin converting enzyme inhibitors (ACEIs) and statins. A total of 557 patients (mean age: 53±10 years; 85%; males) who underwent PCI were included. The majority of patients (84.6%) received ≥6 medications (polypharmacy group) while only 15.4% patients received ≥5 medications (nonpolypharmacy group). The two groups were comparable in term of gender, nationality, socioeconomic status and medical insurance. The non-polypharmacy patients had significantly higher adherence to first refill of DAPT compared with patients in the polypharmacy group (100 vs. 76.9%; p=0.001). Similarly, the non-polypharmacy patients were significantly more adherent to secondary preventive medications (BB, ACEI and statins) than the polypharmacy group. In patients who underwent PCI, polypharmacy at discharge could play a negative role in the adherence to the first refill of EBM. Further studies should investigate other parameters that contribute to long term non-adherence.

  18. [Application of Da Vinci surgical robot in the dissection of splenic hilar lymph nodes for gastric cancer patients with total gastrectomy].

    Science.gov (United States)

    Yang, Kun; Chen, Xinzu; Zhang, Weihan; Chen, Xiaolong; Hu, Jiankun

    2016-08-25

    To investigate the feasibility and safety of Da Vinci surgical robot in the dissection of splenic hilar lymph nodes for gastric cancer patients with total gastrectomy. Clinical data of two cases who underwent total gastrectomy for cardia cancer at our department in January 2016 were analyzed retrospectively. Two male patients were 62 and 55 years old respectively, with preoperative diagnosis as cT2-3N0M0 and cT1-2N0M0 gastric cancer by gastroscope and biopsy, and both received robotic total gastrectomy spleen-preserving splenic hilar lymph node dissection successfully. The operative time for splenic hilar lymph node dissection was 30 min and 25 min respectively. The intraoperative estimated blood loss was both 100 ml, while the number of total harvested lymph node was 38 and 33 respectively. One dissected splenic hilar lymph node and fatty tissues in two patients were proven by pathological examinations. There were no anastomotic leakage, pancreatic fistula, splenic infarction, intraluminal bleeding, digestive tract bleeding, aneurysm of splenic artery, and other operation-associated complications. Both patients suffered from postoperative pneumonia, and were cured by conservative therapy. The robotic spleen-preserving splenic hilar lymph node dissection is feasible and safe, but its superiority needs further evaluation.

  19. Robotic-assisted transoral removal of a bilateral floor of mouth ranulas

    Directory of Open Access Journals (Sweden)

    Stromeyer Frederick W

    2011-07-01

    Full Text Available Abstract Objective To describe the management of bilateral oral ranulas with the use of the da Vinci Si Surgical System and discuss advantages and disadvantages over traditional transoral resection. Study Design Case Report and Review of Literature. Results A 47 year old woman presented to our service with an obvious right floor of mouth swelling. Clinical evaluation and computerized tomography scan confirmed a large floor of mouth ranula on the right and an incidental asymptomatic early ranula of the left sublingual gland. After obtaining an informed consent, the patient underwent a right transoral robotic-assisted transoral excision of the ranula and sublingual gland with identification and dissection of the submandibular duct and lingual nerve. The patient had an excellent outcome with no evidence of lingual nerve paresis and a return to oral intake on the first postoperative day. Subsequently, the patient underwent an elective transoral robotic-assisted excision of the incidental ranula on the left sublingual gland. Conclusion We describe the first robotic-assisted excision of bilateral oral ranulas in current literature. The use of the da Vinci system provides excellent visualization, magnification, and dexterity for transoral surgical management of ranulas with preservation of the lingual nerve and Wharton's duct with good functional outcomes. However, the use of the robotic system for anterior floor of mouth surgery in terms of improved surgical outcomes as compared to traditional transoral surgery, long-term recurrence rates, and cost effectiveness needs further validation.

  20. Robot-assisted gait training for stroke patients: current state of the art and perspectives of robotics

    Directory of Open Access Journals (Sweden)

    Morone G

    2017-05-01

    Full Text Available Giovanni Morone,1,2 Stefano Paolucci,1,2 Andrea Cherubini,3 Domenico De Angelis,1 Vincenzo Venturiero,1 Paola Coiro,1 Marco Iosa1,2 1Private Inpatient Unit, 2Clinical Laboratory of Experimental Neurorehabilitation, IRCCS Santa Lucia Foundation, Rome, Italy; 3Department of Robotics, LIRMM UM-CNRS, Montpellier, France Abstract: In this review, we give a brief outline of robot-mediated gait training for stroke patients, as an important emerging field in rehabilitation. Technological innovations are allowing rehabilitation to move toward more integrated processes, with improved efficiency and less long-term impairments. In particular, robot-mediated neurorehabilitation is a rapidly advancing field, which uses robotic systems to define new methods for treating neurological injuries, especially stroke. The use of robots in gait training can enhance rehabilitation, but it needs to be used according to well-defined neuroscientific principles. The field of robot-mediated neurorehabilitation brings challenges to both bioengineering and clinical practice. This article reviews the state of the art (including commercially available systems and perspectives of robotics in poststroke rehabilitation for walking recovery. A critical revision, including the problems at stake regarding robotic clinical use, is also presented. Keywords: exoskeleton, neurorehabilitation, robot-assisted walking training, wearable robot, activities of daily living, motor learning, plasticity

  1. Adoption of robotics in a general surgery residency program: at what cost?

    Science.gov (United States)

    Mehaffey, J Hunter; Michaels, Alex D; Mullen, Matthew G; Yount, Kenan W; Meneveau, Max O; Smith, Philip W; Friel, Charles M; Schirmer, Bruce D

    2017-06-01

    Robotic technology is increasingly being utilized by general surgeons. However, the impact of introducing robotics to surgical residency has not been examined. This study aims to assess the financial costs and training impact of introducing robotics at an academic general surgery residency program. All patients who underwent laparoscopic or robotic cholecystectomy, ventral hernia repair (VHR), and inguinal hernia repair (IHR) at our institution from 2011-2015 were identified. The effect of robotic surgery on laparoscopic case volume was assessed with linear regression analysis. Resident participation, operative time, hospital costs, and patient charges were also evaluated. We identified 2260 laparoscopic and 139 robotic operations. As the volume of robotic cases increased, the number of laparoscopic cases steadily decreased. Residents participated in all laparoscopic cases and 70% of robotic cases but operated from the robot console in only 21% of cases. Mean operative time was increased for robotic cholecystectomy (+22%), IHR (+55%), and VHR (+61%). Financial analysis revealed higher median hospital costs per case for robotic cholecystectomy (+$411), IHR (+$887), and VHR (+$1124) as well as substantial associated fixed costs. Introduction of robotic surgery had considerable negative impact on laparoscopic case volume and significantly decreased resident participation. Increased operative time and hospital costs are substantial. An institution must be cognizant of these effects when considering implementing robotics in departments with a general surgery residency program. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Factors related to postoperative pain among patients who underwent radiofrequency ablation of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Hsieh, Y.-C.; Yap, Y.-S.; Hung, C.-H.; Chen, C.-H.; Lu, S.-N.; Wang, J.-H.

    2013-01-01

    Aim: To evaluate the incidence and associated factors of postoperative intense pain and haemodynamic changes during radiofrequency ablation of hepatocellular carcinoma. Materials and methods: A total of 123 consecutive hepatocellular carcinoma patients who underwent radiofrequency ablation were prospectively recruited. Patient factors, tumour characteristics, procedural factors, intraoperative haemodynamic changes, complications, postoperative events, laboratory values before and after ablation, and postoperative pain were evaluated. Postoperative pain was scored using a visual analogue scale after the procedure. Results: The mean age of the patients was 65.6 ± 9.6 years. In multiple logistic regression analysis, patients who underwent general anaesthesia [odds ratio (95% CI): 2.68 (1.23–5.81); p = 0.013] and had more postoperative nausea and vomiting episodes [3.10 (1.11–8.63); p = 0.036] were associated with intense pain. These findings remain robust after propensity score matching. For mean difference values between before and after RFA, higher in change in aspartate transaminase (p = 0.026), alanine transaminase (p = 0.016) and white blood cell count (p = 0.015), and lower in change in haemoglobin (p = 0.009) were also correlated with intense pain. There was no significant difference in haemodynamic changes between the general anaesthesia and local anaesthesia group during ablation. Conclusion: General anaesthesia, postoperative nausea and vomiting, and laboratory factors were associated with postoperative intense pain in patients who underwent radiofrequency ablation. Counselling and modification of analgesics should be considered in patients with related factors for intense pain

  3. Robotic Colorectal Resection With and Without the Use of the New Da Vinci Table Motion: A Case-Matched Study.

    Science.gov (United States)

    Palmeri, Matteo; Gianardi, Desirée; Guadagni, Simone; Di Franco, Gregorio; Bastiani, Luca; Furbetta, Niccolò; Simoncini, Tommaso; Zirafa, Cristina; Melfi, Franca; Buccianti, Piero; Moglia, Andrea; Cuschieri, Alfred; Mosca, Franco; Morelli, Luca

    2018-06-01

    The da Vinci Table Motion (dVTM) is a new device that enables patients to be repositioned with instruments in place within the abdomen, and without undocking the robot. The present study was designed to compare operative and short-term outcomes of patients undergoing colorectal cancer surgery with the da Vinci Xi system, with or without use of the dVTM. Ten patients underwent robotic colorectal resection for cancer with the use of dVTM (Xi-dVTM group) between May 2015 and October 2015 at our center. The intraoperative and short-term clinical outcome were compared, using a case-control methodology (propensity scores approach to create 1:2 matched pairs), with a similar group of patients who underwent robotic colorectal surgery for cancer without the use of the dVTM device (Xi-only group). Overall robotic operative time was shorter in the Xi-dVTM group ( P = .04). Operations were executed fully robotic in all Xi-dVTM cases, while 2 cases of the Xi-only group required conversion to open surgery because of bulky tumors and difficult exposure. Postoperative medical complications were higher in the Xi-only group ( P = .024). In this preliminary experience, the use of the new dVTM with the da Vinci Xi in colorectal surgery, by overcoming the limitations of the fixed positions of the patient, enhanced the workflow and resulted in improved exposure of the operative field. Further studies with a greater number of patients are needed to confirm these benefits of the dVTM-da Vinci Xi robotically assisted colorectal surgery.

  4. Design strategies to improve patient motivation during robot-aided rehabilitation

    Directory of Open Access Journals (Sweden)

    Carrozza M Chiara

    2007-02-01

    Full Text Available Abstract Background Motivation is an important factor in rehabilitation and frequently used as a determinant of rehabilitation outcome. Several factors can influence patient motivation and so improve exercise adherence. This paper presents the design of two robot devices for use in the rehabilitation of upper limb movements, that can motivate patients during the execution of the assigned motor tasks by enhancing the gaming aspects of rehabilitation. In addition, a regular review of the obtained performance can reinforce in patients' minds the importance of exercising and encourage them to continue, so improving their motivation and consequently adherence to the program. In view of this, we also developed an evaluation metric that could characterize the rate of improvement and quantify the changes in the obtained performance. Methods Two groups (G1, n = 8 and G2, n = 12 of patients with chronic stroke were enrolled in a 3-week rehabilitation program including standard physical therapy (45 min. daily plus treatment by means of robot devices (40 min., twice daily respectively for wrist (G1 and elbow-shoulder movements (G2. Both groups were evaluated by means of standard clinical assessment scales and the new robot measured evaluation metric. Patients' motivation was assessed in 9/12 G2 patients by means of the Intrinsic Motivation Inventory (IMI questionnaire. Results Both groups reduced their motor deficit and showed a significant improvement in clinical scales and the robot measured parameters. The IMI assessed in G2 patients showed high scores for interest, usefulness and importance subscales and low values for tension and pain subscales. Conclusion Thanks to the design features of the two robot devices the therapist could easily adapt training to the individual by selecting different difficulty levels of the motor task tailored to each patient's disability. The gaming aspects incorporated in the two rehabilitation robots helped maintain

  5. Robotic repair of retrocaval ureter: A case series | Nayak | African ...

    African Journals Online (AJOL)

    Subjects and methods: This is a prospective case series of five consecutive patients who underwent robotic retrocaval ureter repair at our institute from August 2006 to September 2009. Pre-operative imaging included intravenous urogram, contrast enhanced CT scan and diuretic renography. All cases were done through a ...

  6. Compensating Hand Function in Chronic Stroke Patients Through the Robotic Sixth Finger.

    Science.gov (United States)

    Salvietti, Gionata; Hussain, Irfan; Cioncoloni, David; Taddei, Sabrina; Rossi, Simone; Prattichizzo, Domenico

    2017-02-01

    A novel solution to compensate hand grasping abilities is proposed for chronic stroke patients. The goal is to provide the patients with a wearable robotic extra-finger that can be worn on the paretic forearm by means of an elastic band. The proposed prototype, the Robotic Sixth Finger, is a modular articulated device that can adapt its structure to the grasped object shape. The extra-finger and the paretic hand act like the two parts of a gripper cooperatively holding an object. We evaluated the feasibility of the approach with four chronic stroke patients performing a qualitative test, the Frenchay Arm Test. In this proof of concept study, the use of the Robotic Sixth Finger has increased the total score of the patients by two points in a five points scale. The subjects were able to perform the two grasping tasks included in the test that were not possible without the robotic extra-finger. Adding a robotic opposing finger is a very promising approach that can significantly improve the functional compensation of the chronic stroke patient during everyday life activities.

  7. The decisive role of the patient-side surgeon in robotic surgery.

    Science.gov (United States)

    Sgarbura, Olivia; Vasilescu, Catalin

    2010-12-01

    Minimally invasive technology literature is mainly concerned about the feasibility of the robotic procedures and the performance of the console surgeon. However, few of these technologies could be applied without a well-trained team. Our goal was to demonstrate that robotic surgery depends more on the patient-side assistant surgeon's abilities than has been previously reported. In our department, 280 interventions in digestive, thoracic, and gynecological surgery were performed since the acquisition of the robotic equipment. There are three teams trained in robotic surgery with three console surgeons and four certified patient-side surgeons. Four more patient-side assistants were trained at our center. Trocar placement, docking and undocking of the robot, insertion of the laparoscopic instruments, and hemostatic maneuvers with various devices were quantified and compared. Assistants trained by using animal or cadaver surgery are more comfortable with the robotic instruments handling and with docking and undocking of the robot. Assistants who finalized their residency or attend their final year are more accurate with the insertion of the laparoscopic instrument to the targeted organ and more skillful with LigaSure or clip applier devices. Interventions that require vivid participation of the assistants have shorter assistant-depending time intervals at the end of the learning curve than at the beginning. Robotic surgery is a team effort and is greatly dependant on the performance of assistant surgeons. Interventions that have the benefit of a trained team are more rapid and secure.

  8. Hand Robotics Rehabilitation: Feasibility and Preliminary Results of a Robotic Treatment in Patients with Hemiparesis

    Directory of Open Access Journals (Sweden)

    Patrizio Sale

    2012-01-01

    Full Text Available Background. No strongly clinical evidence about the use of hand robot-assisted therapy in stroke patients was demonstrated. This preliminary observer study was aimed at evaluating the efficacy of intensive robot-assisted therapy in hand function recovery, in the early phase after a stroke onset. Methods. Seven acute ischemic stroke patients at their first-ever stroke were enrolled. Treatment was performed using Amadeo robotic system (Tyromotion GmbH Graz, Austria. Each participant received, in addition to inpatients standard rehabilitative treatment, 20 sessions of robotic treatment for 4 consecutive weeks (5 days/week. Each session lasted for 40 minutes. The exercises were carried out as follows: passive modality (5 minutes, passive/plus modality (5 minutes, assisted therapy (10 minutes, and balloon (10 minutes. The following impairment and functional evaluations, Fugl-Meyer Scale (FM, Medical Research Council Scale for Muscle Strength (hand flexor and extensor muscles (MRC, Motricity Index (MI, and modified Ashworth Scale for wrist and hand muscles (AS, were performed at the beginning (T0, after 10 sessions (T1, and at the end of the treatment (T2. The strength hand flexion and extension performed by Robot were assessed at T0 and T2. The Barthel Index and COMP (performance and satisfaction subscale were assessed at T0 and T2. Results. Clinical improvements were found in all patients. No dropouts were recorded during the treatment and all subjects fulfilled the protocol. Evidence of a significant improvement was demonstrated by the Friedman test for the MRC (P<0.0123. Evidence of an improvement was demonstrated for AS, FM, and MI. Conclusions. This original rehabilitation treatment could contribute to increase the hand motor recovery in acute stroke patients. The simplicity of the treatment, the lack of side effects, and the first positive results in acute stroke patients support the recommendations to extend the clinical trial of this

  9. A prospective comparison of postoperative pain and quality of life in robotic assisted vs conventional laparoscopic gynecologic surgery.

    Science.gov (United States)

    Zechmeister, Jenna R; Pua, Tarah L; Boyd, Leslie R; Blank, Stephanie V; Curtin, John P; Pothuri, Bhavana

    2015-02-01

    We sought to compare robotic vs laparoscopic surgery in regards to patient reported postoperative pain and quality of life. This was a prospective study of patients who presented for treatment of a new gynecologic disease requiring minimally invasive surgical intervention. All subjects were asked to take the validated Brief Pain Inventory-Short Form at 3 time points to assess pain and its effect on quality of life. Statistical analyses were performed using Pearson x(2) and Student's t test. One hundred eleven were included in the analysis of which 56 patients underwent robotic assisted surgery and 55 patients underwent laparoscopic surgery. There was no difference in postoperative pain between conventional laparoscopy and robotic assisted surgery for gynecologic procedures. There was a statistically significant difference found at the delayed postoperative period when evaluating interference of sleep, favoring laparoscopy (ROB 2.0 vs LSC 1.0; P = .03). There were no differences found between the robotic and laparoscopic groups of patients receiving narcotics (56 vs 53, P = .24, respectively), route of administration of narcotics (47 vs 45, P > .99, respectively), or administration of nonsteroidal antiinflammatory medications (27 vs 21, P = .33, respectively). Our results demonstrate no difference in postoperative pain between conventional laparoscopy and robotic assisted surgery for gynecologic procedures. Furthermore, pain did not appear to interfere consistently with any daily activity of living. Interference of sleep needs to be further evaluated after controlling for bilateral salpingo-oophorectomy. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Animal Robot Assisted-therapy for Rehabilitation of Patient with Post-Stroke Depression

    Science.gov (United States)

    Zikril Zulkifli, Winal; Shamsuddin, Syamimi; Hwee, Lim Thiam

    2017-06-01

    Recently, the utilization of therapeutic animal robots has expanded. This research aims to explore robotics application for mental healthcare in Malaysia through human-robot interaction (HRI). PARO, the robotic seal PARO was developed to give psychological effects on humans. Major Depressive Disorder (MDD) is a common but severe mood disorder. This study focuses on the interaction protocol between PARO and patients with MDD. Initially, twelve rehabilitation patients gave subjective evaluation on their first interaction with PARO. Next, therapeutic interaction environment was set-up with PARO in it to act as an augmentation strategy with other psychological interventions for post-stroke depression. Patient was exposed to PARO for 20 minutes. The results of behavioural analysis complemented with information from HRI survey question. The analysis also observed that the individual interactors engaged with the robot in diverse ways based on their needs Results show positive reaction toward the acceptance of an animal robot. Next, therapeutic interaction is set-up for PARO to contribute as an augmentation strategy with other psychological interventions for post-stroke depression. The outcome is to reduce the stress level among patients through facilitated therapy session with PARO

  11. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available BackgroundRobots have allowed head and neck surgeons to extirpate oropharyngeal tumors safely without the need for lip-split incision or mandibulotomy. Using robots in oropharyngeal reconstruction is new but essential for oropharyngeal defects that result from robotic tumor excision. We report our experience with robotic free-flap reconstruction of head and neck defects to exemplify the necessity for robotic reconstruction.MethodsWe investigated head and neck cancer patients who underwent ablation surgery and free-flap reconstruction by robot. Between July 1, 2011 and March 31, 2012, 5 cases were performed and patient demographics, location of tumor, pathologic stage, reconstruction methods, flap size, recipient vessel, necessary pedicle length, and operation time were investigated.ResultsAmong five free-flap reconstructions, four were radial forearm free flaps and one was an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and one flap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flap insetting and microanastomosis were achieved using a specially manufactured robotic instrument. The total operation time was 1,041.0 minutes (range, 814 to 1,132 minutes, and complications including flap necrosis, hematoma, and wound dehiscence did not occur.ConclusionsThis study demonstrates the clinically applicable use of robots in oropharyngeal reconstruction, especially using a free flap. A robot can assist the operator in insetting the flap at a deep portion of the oropharynx without the need to perform a traditional mandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methods and is accepted as the most up-to-date method.

  12. Robot-assisted procedures in pediatric neurosurgery.

    Science.gov (United States)

    De Benedictis, Alessandro; Trezza, Andrea; Carai, Andrea; Genovese, Elisabetta; Procaccini, Emidio; Messina, Raffaella; Randi, Franco; Cossu, Silvia; Esposito, Giacomo; Palma, Paolo; Amante, Paolina; Rizzi, Michele; Marras, Carlo Efisio

    2017-05-01

    OBJECTIVE During the last 3 decades, robotic technology has rapidly spread across several surgical fields due to the continuous evolution of its versatility, stability, dexterity, and haptic properties. Neurosurgery pioneered the development of robotics, with the aim of improving the quality of several procedures requiring a high degree of accuracy and safety. Moreover, robot-guided approaches are of special interest in pediatric patients, who often have altered anatomy and challenging relationships between the diseased and eloquent structures. Nevertheless, the use of robots has been rarely reported in children. In this work, the authors describe their experience using the ROSA device (Robotized Stereotactic Assistant) in the neurosurgical management of a pediatric population. METHODS Between 2011 and 2016, 116 children underwent ROSA-assisted procedures for a variety of diseases (epilepsy, brain tumors, intra- or extraventricular and tumor cysts, obstructive hydrocephalus, and movement and behavioral disorders). Each patient received accurate preoperative planning of optimal trajectories, intraoperative frameless registration, surgical treatment using specific instruments held by the robotic arm, and postoperative CT or MR imaging. RESULTS The authors performed 128 consecutive surgeries, including implantation of 386 electrodes for stereo-electroencephalography (36 procedures), neuroendoscopy (42 procedures), stereotactic biopsy (26 procedures), pallidotomy (12 procedures), shunt placement (6 procedures), deep brain stimulation procedures (3 procedures), and stereotactic cyst aspiration (3 procedures). For each procedure, the authors analyzed and discussed accuracy, timing, and complications. CONCLUSIONS To the best their knowledge, the authors present the largest reported series of pediatric neurosurgical cases assisted by robotic support. The ROSA system provided improved safety and feasibility of minimally invasive approaches, thus optimizing the surgical

  13. Starting a robotic program in general thoracic surgery: why, how, and lessons learned.

    Science.gov (United States)

    Cerfolio, Robert J; Bryant, Ayesha S; Minnich, Douglas J

    2011-06-01

    We report our experience in starting a robotic program in thoracic surgery. We retrospectively reviewed our experience in starting a robotic program in general thoracic surgery on a consecutive series of patients. Between February 2009 and September 2010, 150 patients underwent robotic operations. Types of procedures were lobectomy in 62, thymectomy in 30, and benign esophageal procedures in 6. No thymectomy or esophageal procedures required conversion. One conversion was needed for suspected bleeding for a mediastinal mass. Twelve patients were converted for lobectomy (none for bleeding, 1 in the last 24). Median operative time for robotic thymectomy was 119 minutes, and median length of stay was 1 day. The median time for robotic lobectomy was 185 minutes, and median length of stay was 2 days. There were no operative deaths. Morbidity occurred in 23 patients (15%). All patients with cancer had R0 resections and resection of all visible mediastinal and hilar lymph nodes. Robotic surgery is safe and oncologically sound. It requires training of the entire operating room team. The learning curve is steep, involving port placement, availability of the proper instrumentation, use of the correct robotic arms, and proper patient positioning. The robot provides an ideal surgical approach for thymectomy and other mediastinal tumors. Its advantage over thoracoscopy for pulmonary resection is unproven; however, we believe complete thoracic lymph node dissection and teaching is easier. Importantly, defined credentialing for surgeons and cost analysis studies are needed. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. The financial impact of robotic technology for partial and radical nephrectomy.

    Science.gov (United States)

    Kates, Max; Ball, Mark W; Patel, Hiten D; Gorin, Michael A; Pierorazio, Phillip M; Allaf, Mohamad E

    2015-03-01

    We sought to evaluate the financial impact of robotic technology for partial nephrectomy (PN) and radical nephrectomy (RN) in the state of Maryland. The Maryland Health Services Cost Review Commission (HSCRC) documents all acute care hospital charges data. This database was queried for patients who underwent laparoscopic or robot-assisted RN and PN from 2008 to 2012. Total hospital charge, subcharge, and length of stay (LOS) were analyzed separately for RN and PN. Overall, 2834 patients were identified. Of those, 282 were laparoscopic PN (LPN), 1078 robot-assisted PN (RPN), 1098 laparoscopic RN (LRN), and 376 robot-assisted RN (RRN). For PN, the total hospital charge was $19,062 for LPN and $18,255 for RPN (P=0.138), with a charge savings of $807 per case in favor of robotics. For RN, the total hospital charge was $23,391 for RRN and $18,280 for LRN (P=0.004), with a charge premium of $5111 for robotic cases. LOS was shorter for RPN compared with LPN (2.51 vs 2.99 days, Pfinancial implications of RRN use for routine cases warrants further study.

  15. A novel robotic system for single-port urologic surgery: first clinical investigation.

    Science.gov (United States)

    Kaouk, Jihad H; Haber, Georges-Pascal; Autorino, Riccardo; Crouzet, Sebastien; Ouzzane, Adil; Flamand, Vincent; Villers, Arnauld

    2014-12-01

    The idea of performing a laparoscopic procedure through a single abdominal incision was conceived with the aim of expediting postoperative recovery. To determine the clinical feasibility and safety of single-port urologic procedures by using a novel robotic surgical system. This was a prospective institutional review board-approved, Innovation, Development, Exploration, Assessment, Long-term Study (IDEAL) phase 1 study. After enrollment, patients underwent a major urologic robotic single-port procedure over a 3-wk period in July 2010. The patients were followed for 3 yr postoperatively. Different types of urologic surgeries were performed using the da Vinci SP Surgical System. This system is intended to provide the same core clinical capabilities as the existing multiport da Vinci system, except that three articulating endoscopic instruments and an articulating endoscopic camera are inserted into the patient through a single robotic port. The main outcomes were the technical feasibility of the procedures (as measured by the rate of conversions) and the safety of the procedures (as measured by the incidence of perioperative complications). Secondary end points consisted of evaluating other key surgical perioperative outcomes as well as midterm functional and oncologic outcomes. A total of 19 patients were enrolled in the study. Eleven of them underwent radical prostatectomy; eight subjects underwent nephrectomy procedures (partial nephrectomy, four; radical nephrectomy, two; and simple nephrectomy, two). There were no conversions to alternative surgical approaches. Overall, two major (Clavien grade 3b) postoperative complications were observed in the radical prostatectomy group and none in the nephrectomy group. At 1-yr follow-up, one radical prostatectomy patient experienced biochemical recurrence, which was successfully treated with salvage radiation therapy. The median warm ischemia time for three of the partial nephrectomies was 38 min. At 3-yr follow-up all

  16. Prospective study of robotic partial nephrectomy for renal cancer in Japan: Comparison with a historical control undergoing laparoscopic partial nephrectomy.

    Science.gov (United States)

    Tanaka, Kazushi; Teishima, Jun; Takenaka, Atsushi; Shiroki, Ryoichi; Kobayashi, Yasuyuki; Hattori, Kazunori; Kanayama, Hiro-Omi; Horie, Shigeo; Yoshino, Yasushi; Fujisawa, Masato

    2018-05-01

    To evaluate the outcomes of robotic partial nephrectomy compared with those of laparoscopic partial nephrectomy for T1 renal tumors in Japanese centers. Patients with a T1 renal tumor who underwent robotic partial nephrectomy were eligible for inclusion in the present study. The primary end-point consisted of three components: a negative surgical margin, no conversion to open or laparoscopic surgery and a warm ischemia time ≤25 min. We compared data from these patients with the data from a retrospective study of laparoscopic partial nephrectomy carried out in Japan. A total of 108 patients were registered in the present study; 105 underwent robotic partial nephrectomy. The proportion of patients who met the primary end-point was 91.3% (95% confidence interval 84.1-95.9%), which was significantly higher than 23.3% in the historical data. Major complications were seen in 19 patients (18.1%). The mean change in the estimated glomerular filtration rate in the operated kidney, 180 days postoperatively, was -10.8 mL/min/1.73 m 2 (95% confidence interval -12.3-9.4%). Robotic partial nephrectomy for patients with a T1 renal tumor is a safe, feasible and more effective operative method compared with laparoscopic partial nephrectomy. It can be anticipated that robotic partial nephrectomy will become more widely used in Japan in the future. © 2018 The Japanese Urological Association.

  17. Intraoperative seizures and seizures outcome in patients underwent awake craniotomy.

    Science.gov (United States)

    Yuan, Yang; Peizhi, Zhou; Xiang, Wang; Yanhui, Liu; Ruofei, Liang; Shu, Jiang; Qing, Mao

    2016-11-25

    Awake craniotomies (AC) could reduce neurological deficits compared with patients under general anesthesia, however, intraoperative seizure is a major reason causing awake surgery failure. The purpose of the study was to give a comprehensive overview the published articles focused on seizure incidence in awake craniotomy. Bibliographic searches of the EMBASE, MEDLINE,were performed to identify articles and conference abstracts that investigated the intraoperative seizure frequency of patients underwent AC. Twenty-five studies were included in this meta-analysis. Among the 25 included studies, one was randomized controlled trials and 5 of them were comparable studies. The pooled data suggested the general intraoperative seizure(IOS) rate for patients with AC was 8%(fixed effect model), sub-group analysis identified IOS rate for glioma patients was 8% and low grade patients was 10%. The pooled data showed early seizure rates of AC patients was 11% and late seizure rates was 35%. This systematic review and meta-analysis shows that awake craniotomy is a safe technique with relatively low intraoperative seizure occurrence. However, few RCTs were available, and the acquisition of further evidence through high-quality RCTs is highly recommended.

  18. Assistive/Socially Assistive Robotic Platform for Therapy and Recovery: Patient Perspectives

    Directory of Open Access Journals (Sweden)

    Matthew White

    2013-01-01

    Full Text Available Improving adherence to therapy is a critical component of advancing outcomes and reducing the cost of rehabilitation. A robotic platform was previously developed to explore how robotics could be applied to the social dimension of rehabilitation to improve adherence. This paper aims to report on feedback given by end users of the robotic platform as well as the practical applications that socially assistive robotics could have in the daily life activities of a patient. A group of 10 former and current patients interacted with the developed robotic platform during a simulated exercise session before taking an experience-based survey. A portion of these participants later provided verbal feedback as part of a focus group on the potential utility of such a platform. Identified applications included assistance with reaching exercise goals, managing to-do lists, and supporting participation in social and recreational activities. The study participants expressed that the personality characteristics of the robotic system should be adapted to individual preferences and that the assistance provided over time should align with the progress of their recovery. The results from this study are encouraging and will be useful for further development of socially assistive robotics.

  19. Perioperative risk assessment in robotic general surgery: lessons learned from 884 cases at a single institution.

    Science.gov (United States)

    Buchs, Nicolas C; Addeo, Pietro; Bianco, Francesco M; Gorodner, Veronica; Ayloo, Subhashini M; Elli, Enrique F; Oberholzer, José; Benedetti, Enrico; Giulianotti, Pier C

    2012-08-01

    To assess factors associated with morbidity and mortality following the use of robotics in general surgery. Case series. University of Illinois at Chicago. Eight hundred eighty-four consecutive patients who underwent a robotic procedure in our institution between April 2007 and July 2010. Perioperative morbidity and mortality. During the study period, 884 patients underwent a robotic procedure. The conversion rate was 2%, the mortality rate was 0.5%, and the overall postoperative morbidity rate was 16.7%. The reoperation rate was 2.4%. Mean length of stay was 4.5 days (range, 0.2-113 days). In univariate analysis, several factors were associated with increased morbidity and included either patient-related (cardiovascular and renal comorbidities, American Society of Anesthesiologists score ≥ 3, body mass index [calculated as weight in kilograms divided by height in meters squared] surgery, malignant disease, body mass index of less than 30, hypertension, and transfusion were factors significantly associated with a higher risk for complications. American Society of Anesthesiologists score of 3 or greater, age 70 years or older, cardiovascular comorbidity, and blood loss of 500 mL or more were also associated with increased risk for mortality. Use of the robotic approach for general surgery can be achieved safely with low morbidity and mortality. Several risk factors have been identified as independent causes for higher morbidity and mortality. These can be used to identify patients at risk before and during the surgery and, in the future, to develop a scoring system for the use of robotic general surgery

  20. Prospective analysis of completely stentless robot-assisted pyeloplasty in children.

    Science.gov (United States)

    Casale, Pasquale; Lambert, Sarah

    2010-01-01

    Robot-assisted pyeloplasty (RAP) is emerging as an effective tool for treatment of ureteropelvic junction obstruction (UPJO) in the pediatric population. Typically stents are utilized for RAP and removed four weeks after the procedure. We present our prospective experience with stentless RAP. Twenty children between the ages of 12 and 113 months (mean age 56 months) underwent transperitoneal RAP for UPJO utilizing the DaVinci surgical system. Outcome measures included operative time, length of hospital stay, and resolution of obstruction by ultrasonography, magnetic resonance urography (MRU), and/or diuretic radionuclide imaging (DRI). All patients successfully underwent robot-assisted laparoscopic pyeloplasty without conversion to pure laparoscopy or open procedure. Mean operative time was 124.7 min with a mean console time of 82.3 min. The mean hospital stay was 18 h. Of the 20 patients, 13/20 (65%) had resolution or improvement in the degree of hydronephrosis. The other patients had no evidence of obstruction based upon follow-up MRU or DRI. Stentless RAP is a safe and effective option for surgical treatment of UPJO. A larger prospective long-term cohort is needed to confirm the safety and efficacy of the stentless approach.

  1. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available Background  Robots have allowed head and neck surgeons to extirpate oropharyngealtumors safely without the need for lip-split incision or mandibulotomy. Using robots inoropharyngealreconstruction is newbut essentialfor oropharyngeal defectsthatresultfromrobotic tumor excision. We report our experience with robotic free-flap reconstruction ofhead and neck defectsto exemplify the necessity forrobotic reconstruction.Methods  We investigated head and neck cancer patients who underwent ablation surgeryand free-flap reconstruction by robot. Between July 1, 2011 andMarch 31, 2012, 5 caseswereperformed and patient demographics, location of tumor, pathologic stage, reconstructionmethods, flap size, recipient vessel, necessary pedicle length, and operation time wereinvestigated.Results  Among five free-flap reconstructions, four were radial forearm free flaps and onewas an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and oneflap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flapinsetting and microanastomosis were achieved using a specially manufactured roboticinstrument. The total operation timewas 1,041.0 minutes(range, 814 to 1,132 minutes, andcomplicationsincluding flap necrosis, hematoma, andwound dehiscence did not occur.Conclusions  Thisstudy demonstratesthe clinically applicable use ofrobotsin oropharyngealreconstruction, especially using a free flap. A robot can assist the operator in insettingthe flap at a deep portion of the oropharynx without the need to perform a traditionalmandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methodsand is accepted asthemost up-to-datemethod.

  2. [Robots in general surgery: present and future].

    Science.gov (United States)

    Galvani, Carlos; Horgan, Santiago

    2005-09-01

    Robotic surgery is an emerging technology. We began to use this technique in 2000, after it was approved by the Food and Drug Administration. Our preliminary experience was satisfactory. We report 4 years' experience of using this technique in our institution. Between August 2000 and December 2004, 399 patients underwent robotic surgery using the Da Vinci system. We performed 110 gastric bypass procedures, 30 Lap band, 59 Heller myotomies, 12 Nissen fundoplications, 6 epiphrenic diverticula, 18 total esophagectomies, 3 esophageal leiomyoma resections, 1 pyloroplasty, 2 gastrojejunostomies, 2 transduodenal sphincteroplasties, 10 adrenalectomies and 145 living-related donor nephrectomies. Operating times for fundoplications and Lap band were longer. After the learning curve, the operating times and morbidity of the remaining procedures were considerably reduced. Robot-assisted surgery allows advanced laparoscopic procedures to be performed with enhanced results given that it reduces the learning curve as measured by operating time and morbidity.

  3. Robotic surgery in urological oncology: patient care or market share?

    Science.gov (United States)

    Kaye, Deborah R; Mullins, Jeffrey K; Carter, H Ballentine; Bivalacqua, Trinity J

    2015-01-01

    Surgical robotic use has grown exponentially in spite of limited or uncertain benefits and large costs. In certain situations, adoption of robotic technology provides value to patients and society. In other cases, however, the robot provides little or no increase in surgical quality, with increased expense, and, therefore, does not add value to health care. The surgical robot is expensive to purchase, maintain and operate, and can contribute to increased consumerism in relation to surgical procedures, and increased reliance on the technology, thus driving future increases in health-care expenditure. Given the current need for budget constraints, the cost-effectiveness of specific procedures must be evaluated. The surgical robot should be used when cost-effective, but traditional open and laparoscopic techniques also need to be continually fostered.

  4. Technology advances in hospital practices: robotics in treatment of patients.

    Science.gov (United States)

    Rosiek, Anna; Leksowski, Krzysztof

    2015-06-01

    Laparoscopic cholecystectomy is widely considered as the treatment of choice for acute cholecystitis. The safety of the procedure and its minimal invasiveness made it a valid treatment option for a patient not responding to antibiotic therapy. Our research shows that patients positively assess this treatment method, but the world's tendency is to turn to a more sophisticated method utilizing robot-assisted surgery as a gold standard. Providing patient with minimally invasive surgical procedures that utilize the state-of-the-art equipment like the da Vinci Robotic Surgical System underscores the commitment to high-quality patient care while enhancing patient safety. The advantages include minimal invasive scarring, less pain and bleeding, faster recovery time, and shorter hospital stay. The move toward less invasive and less morbid procedures and a need to re-create the true open surgical experience have paved the way for the development and application of robotic and computer-assisted systems in surgery in Poland as well as the rest of the world. © The Author(s) 2014.

  5. Does robotic assistance confer an economic benefit during laparoscopic radical nephrectomy?

    Science.gov (United States)

    Yang, David Y; Monn, M Francesca; Bahler, Clinton D; Sundaram, Chandru P

    2014-09-01

    While robotic assisted radical nephrectomy is safe with outcomes and complication rates comparable to those of the pure laparoscopic approach, there is little evidence of an economic or clinical benefit. From the 2009 to 2011 Nationwide Inpatient Sample database we identified patients 18 years old or older who underwent radical nephrectomy for primary renal malignancy. Robotic assisted and laparoscopic techniques were noted. Patients treated with the open technique and those with evidence of metastatic disease were excluded from analysis. Descriptive statistics were performed using the chi-square and Mann-Whitney tests, and the Student t-test. Multiple linear regression was done to examine factors associated with increased hospital costs and charges. We identified 24,312 radical nephrectomy cases for study inclusion, of which 7,787 (32%) were performed robotically. There was no demographic difference between robotic assisted and pure laparoscopic radical nephrectomy cases. Median total charges were $47,036 vs $38,068 for robotic assisted vs laparoscopic surgery (p robotic assisted surgery were $15,149 compared to $11,735 for laparoscopic surgery (p robotic assistance conferred an estimated $4,565 and $11,267 increase in hospital costs and charges, respectively, when adjusted for adapted Charlson comorbidity index score, perioperative complications and length of stay (p Robotic assisted radical nephrectomy results in increased medical expense without improving patient morbidity. Assuming surgeon proficiency with pure laparoscopy, robotic technology should be reserved primarily for complex surgeries requiring reconstruction. Traditional laparoscopic techniques should continue to be used for routine radical nephrectomy. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Perioperative analgesic requirements in severely obese adolescents and young adults undergoing laparoscopic versus robotic-assisted gastric sleeve resection

    Directory of Open Access Journals (Sweden)

    Anita Joselyn

    2015-01-01

    Full Text Available Purpose: One of the major advantages for patients undergoing minimally invasive surgery as compared to an open surgical procedure is the improved recovery profile and decreased opioid requirements in the perioperative period. There are no definitive studies comparing the analgesic requirements in patients undergoing two different types of minimally invasive procedure. This study retrospectively compares the perioperative analgesic requirements in severely obese adolescents and young adults undergoing laparoscopic versus robotic-assisted, laparoscopic gastric sleeve resection. Materials and Methods: With Institutional Review Board approval, the medication administration records of all severely obese patients who underwent gastric sleeve resection were retrospectively reviewed. Intra-operative analgesic and adjuvant medications administered, postoperative analgesic requirements, and visual analog pain scores were compared between those undergoing a laparoscopic procedure versus a robotic-assisted procedure. Results: This study cohort included a total of 28 patients who underwent gastric sleeve resection surgery with 14 patients in the laparoscopic group and 14 patients in the robotic-assisted group. Intra-operative adjuvant administration of both intravenous acetaminophen and ketorolac was similar in both groups. Patients in the robotic-assisted group required significantly less opioid during the intra-operative period as compared to patients in the laparoscopic group (0.15 ± 0.08 mg/kg vs. 0.19 ± 0.06 mg/kg morphine, P = 0.024. Cumulative opioid requirements for the first 72 postoperative h were similar in both the groups (0.64 ± 0.25 vs. 0.68 ± 0.27 mg/kg morphine, P = NS. No difference was noted in the postoperative pain scores. Conclusion: Although intraoperative opioid administration was lower in the robotic-assisted group, the postoperative opioid requirements, and the postoperative pain scores were similar in both groups.

  7. Anastomotic complications after robot-assisted laparoscopic and open radical prostatectomy

    DEFF Research Database (Denmark)

    Jacobsen, André; Berg, Kasper Drimer; Iversen, Peter

    2016-01-01

    Objective Anastomotic complications are well known after radical prostatectomy (RP). The vesicourethral anastomotic technique is handled differently between open and robotic RP. The aim of the study was to investigate whether the frequency of anastomotic leakages and strictures differed between...... patients undergoing retropubic radical prostatectomy (RRP) and robot-assisted radical prostatectomy (RARP) and to identify risk factors associated with these complications. Materials and methods The study included 735 consecutive patients who underwent RRP (n = 499) or RARP (236) at the Department...... of Urology, Rigshospitalet, Denmark, in a complete 3 year period from 2010 to 2012. Univariate and multivariate logistic regression analysis was used to analyse associations between surgical procedure (RRP vs RARP) and anastomotic complications. Analyses included age, smoking status, diabetes, hypertension...

  8. Comparison of Robotic Pyeloplasty and Standard Laparoscopic Pyeloplasty in Infants: A Bi-Institutional Study.

    Science.gov (United States)

    Neheman, Amos; Kord, Eyal; Zisman, Amnon; Darawsha, Abd Elhalim; Noh, Paul H

    2018-04-01

    To compare outcomes between robotic pyeloplasty (RP) and standard laparoscopic pyeloplasty (LP) in the infant population for the treatment of ureteropelvic junction (UPJ) obstruction. We performed a retrospective cohort study of all children under 1 year of age who underwent RP or LP at two different medical centers between October 2009 and February 2016. Patient demographics, perioperative data, complications, and results were reviewed. Thirteen patients underwent standard LP, and 21 patients underwent RP during the study period. Median age and median weight at time of operation for the whole cohort were 6.1 months and 7.9 kg. Surgery success rates were similar with 95% and 92% in RP and LP, respectively. There was no statistically significant difference in operating time between the 2 groups, with a median time of 156 minutes in RP (range 125-249) and 192 minutes (range 98-229) in standard LP (P = .35). Median length of hospital stay was significantly shorter in the robotic group with a median stay of 1 day (range 1-3) and 7 days (range 7-12) in the standard LP group.(P comparable complication rate between the 2 groups, 30.8% for LP and 23.8% for RP (P = .65). The minimally invasive dismembered pyeloplasty is safe and effective in the infant population and produces high success rates. The results, complication rates, and operative time were comparable between the two surgical methods while the standard LP demonstrated longer hospital stay. Both the robotic approach and the LP can be successfully utilized for the benefit of infants with UPJ obstruction.

  9. [Findings from Total Colonoscopy in Obstructive Colorectal Cancer Patients Who Underwent Stent Placement as a Bridge to Surgery(BTS)].

    Science.gov (United States)

    Maruo, Hirotoshi; Tsuyuki, Hajime; Kojima, Tadahiro; Koreyasu, Ryohei; Nakamura, Koichi; Higashi, Yukihiro; Shoji, Tsuyoshi; Yamazaki, Masanori; Nishiyama, Raisuke; Ito, Tatsuhiro; Koike, Kota; Ikeda, Takashi; Takayanagi, Yasuhiro; Kubota, Hiroyuki

    2017-11-01

    We clinically investigated 34 patients with obstructive colorectal cancer who underwent placement of a colonic stent as a bridge to surgery(BTS), focusing on endoscopic findings after stent placement.Twenty -nine patients(85.3%)underwent colonoscopy after stent placement, and the entire large intestine could be observed in 28(96.6%).Coexisting lesions were observed in 22(78.6%)of these 28 patients.The lesions comprised adenomatous polyps in 17 patients(60.7%), synchronous colon cancers in 5 patients(17.9%), and obstructive colitis in 3 patients(10.7%), with some overlapping cases.All patients with multiple cancers underwent one-stage surgery, and all lesions were excised at the same time.Colonoscopy after colonic stent placement is important for preoperative diagnosis of coexisting lesions and planning the extent of resection. These considerations support the utility of colonic stenting for BTS.

  10. Dysphagia among Adult Patients who Underwent Surgery for Esophageal Atresia at Birth

    Directory of Open Access Journals (Sweden)

    Valérie Huynh-Trudeau

    2015-01-01

    Full Text Available BACKGROUND: Clinical experiences of adults who underwent surgery for esophageal atresia at birth is limited. There is some evidence that suggests considerable long-term morbidity, partly because of dysphagia, which has been reported in up to 85% of adult patients who undergo surgery for esophageal atresia. The authors hypothesized that dysphagia in this population is caused by dysmotility and/or anatomical anomalies.

  11. Accuracy of robotic patient positioners used in ion beam therapy

    International Nuclear Information System (INIS)

    Nairz, Olaf; Winter, Marcus; Heeg, Peter; Jäkel, Oliver

    2013-01-01

    In this study we investigate the accuracy of industrial six axes robots employed for patient positioning at the Heidelberg Ion Beam Therapy Center. In total 1018 patient setups were monitored with a laser tracker and subsequently analyzed. The measurements were performed in the two rooms with a fixed horizontal beam line. Both, the 3d translational errors and the rotational errors around the three table axes were determined. For the first room the 3d error was smaller than 0.72 mm in 95 percent of all setups. The standard deviation of the rotational errors was at most 0.026° for all axes. For the second room Siemens implemented an improved approach strategy to the final couch positions. The 95 percent quantile of the 3d error could in this room be reduced to 0.53 mm; the standard deviation of the rotational errors was also at most 0.026°. Robots are very flexible tools for patient positioning in six degrees of freedom. This study proved that the robots are able to achieve clinically acceptable accuracy in real patient setups, too

  12. Transitioning from video-assisted thoracic surgical lobectomy to robotics for lung cancer: are there outcomes advantages?

    Science.gov (United States)

    Lee, Benjamin E; Korst, Robert J; Kletsman, Elaine; Rutledge, John R

    2014-02-01

    To determine if there are advantages to transitioning to robotics by a surgeon who is already proficient in performing video-assisted thoracic surgical (VATS) lobectomy. A single surgeon proficient in VATS lobectomy initiated a robotic lobectomy program, and a retrospective review was conducted of his patients undergoing minimally invasive lobectomy (robotics or VATS) for lung cancer between 2011 and 2012. Data collected included patient/tumor characteristics, morbidity, mortality, operative times, and length of hospital stay. Over a 24-month period, a total of 69 patients underwent minimally invasive lobectomy (35 robotic, 34 VATS). Patients in each group were similar in age and clinical stage. Robotic upper lobectomy operative times were longer than VATS (172 vs 134 minutes; P = .001), with no significant difference in lower lobectomies noted (140 vs 123 minutes; P = .1). Median length of stay was 3 days in both groups, and the median number of lymph nodes harvested was 18 (robotic) versus 16 (VATS; P = .42). Morbidity and mortality for robotic versus VATS were 11% versus 18% (P = .46) and 0% versus 3% (P = .49), respectively. There does not seem to be a significant advantage for an established VATS lobectomy surgeon to transition to robotics based on clinical outcomes. The learning curve for robotic upper lobectomies seems to be more significant than that for lower lobectomies. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  13. Application of robotics in general surgery: initial experience.

    Science.gov (United States)

    Nguyen, Ninh T; Hinojosa, Marcelo W; Finley, David; Stevens, Melinda; Paya, Mahbod

    2004-10-01

    Robotic surgery was recently approved for clinical use in general abdominal surgery. The aim of this study was to review our experience with the da Vinci surgical system during laparoscopic general surgical procedures. Eighteen patients underwent robotically assisted laparoscopic abdominal surgery between June 2002 and March 2003. Main outcome measures were operative time, room setup time, robotic arm-positioning and surgical time, blood loss, conversion to laparoscopy, length of stay, and morbidity. The types of robotically assisted laparoscopic procedures were excision of gastric leiomyoma (n = 1), Heller myotomy (n = 1), cholecystectomy (n = 2), gastric banding (n = 2), Nissen fundoplication (n = 4), and gastric bypass (n = 8). The mean room setup time was 63 +/- 14 minutes, and the mean robotic arm-positioning time was 16 +/- 7 minutes. Conversion to laparoscopy occurred in two (11%) of 18 cases because of equipment difficulty (n = 1) and technical difficulty (n = 1). Estimated blood loss was 91 +/- 71 mL. The mean operative time was 156 +/- 42 minutes, and the robotic operative time was 27% of the total operative time. The mean length of hospital stay was 2.2 +/- 1.5 days. There was one postoperative wound infection and one anastomotic stricture. Robotically assisted laparoscopic abdominal surgery is feasible and safe; however, the theoretical advantages of the da Vinci surgical system were not clinically apparent.

  14. Dysphagia among adult patients who underwent surgery for esophageal atresia at birth.

    Science.gov (United States)

    Huynh Trudeau, Valérie; Maynard, Stéphanie; Terzic, Tatjana; Soucy, Geneviève; Bouin, Mickeal

    2015-03-01

    Clinical experiences of adults who underwent surgery for esophageal atresia at birth is limited. There is some evidence that suggests considerable long-term morbidity, partly because of dysphagia, which has been reported in up to 85% of adult patients who undergo surgery for esophageal atresia. The authors hypothesized that dysphagia in this population is caused by dysmotility and⁄or anatomical anomalies. To determine the motor and anatomical causes of dysphagia. A total of 41 adults, followed at the Esophageal Atresia Clinic at Hôpital Saint-Luc (Montreal, Quebec), were approached to particpate in the present prospective study. Evaluation was completed using upper endoscopy, manometry and barium swallow for the participants who consented. The medical charts of respondents were systematically reviewed from the neonatal period to 18 years of age to assess medical and surgical history. All 41 patients followed at the clinic consented and were included in the study. Dysphagia was present in 73% of patients. Esophagogastroduodenoscopy was performed in 32 patients: hiatal hernia was present in 62% (n=20); esophageal diverticulum in 13% (n=4); macroscopic Barrett esophagus in 31% (n=10); and esophagitis in 19% (n=6). Histological esophagitis was present in 20% and intestinal metaplasia in 10%. There were no cases of dysplagia or adenocarcinoma. Esophageal manometry was performed on 56% of the patients (n=23). Manometry revealed hypomotility in 100% of patients and included an insufficient number of peristaltic waves in 96%, nonpropagating peristalsis in 78% and low-wave amplitude in 95%. Complete aperistalsis was present in 78%. The lower esophageal sphincter was abnormal in 12 (52%) patients, with incomplete relaxation the most common anomaly. Of the 41 patients, 29 (71%) consented to a barium swallow, which was abnormal in 13 (45%). The anomalies found were short esophageal dilation in 28%, delay in esophageal emptying in 14%, diverticula in 14% and stenosis in 7

  15. Endoscopic endonasal transsphenoidal surgery using the iArmS operation support robot: initial experience in 43 patients.

    Science.gov (United States)

    Ogiwara, Toshihiro; Goto, Tetsuya; Nagm, Alhusain; Hongo, Kazuhiro

    2017-05-01

    Objective The intelligent arm-support system, iArmS, which follows the surgeon's arm and automatically fixes it at an adequate position, was developed as an operation support robot. iArmS was designed to support the surgeon's forearm to prevent hand trembling and to alleviate fatigue during surgery with a microscope. In this study, the authors report on application of this robotic device to endoscopic endonasal transsphenoidal surgery (ETSS) and evaluate their initial experiences. Methods The study population consisted of 43 patients: 29 with pituitary adenoma, 3 with meningioma, 3 with Rathke's cleft cyst, 2 with craniopharyngioma, 2 with chordoma, and 4 with other conditions. All patients underwent surgery via the endonasal transsphenoidal approach using a rigid endoscope. During the nasal and sphenoid phases, iArmS was used to support the surgeon's nondominant arm, which held the endoscope. The details of the iArmS and clinical results were collected. Results iArmS followed the surgeon's arm movement automatically. It reduced the surgeon's fatigue and stabilized the surgeon's hand during ETSS. Shaking of the video image decreased due to the steadying of the surgeon's scope-holding hand with iArmS. There were no complications related to use of the device. Conclusions The intelligent armrest, iArmS, seems to be safe and effective during ETSS. iArmS is helpful for improving the precision and safety not only for microscopic neurosurgery, but also for ETSS. Ongoing advances in robotics ensure the continued evolution of neurosurgery.

  16. Effect of different pneumoperitoneum pressure on stress state in patients underwent gynecological laparoscopy

    Directory of Open Access Journals (Sweden)

    Ai-Yun Shen

    2016-10-01

    Full Text Available Objective: To observe the effect of different CO2 pneumoperitoneum pressure on the stress state in patients underwent gynecological laparoscopy. Methods: A total of 90 patients who were admitted in our hospital from February, 2015 to October, 2015 for gynecological laparoscopy were included in the study and divided into groups A, B, and C according to different CO2 pneumoperitoneum pressure. The changes of HR, BP, and PetCO2 during the operation process in the three groups were recorded. The changes of stress indicators before operation (T0, 30 min during operation (T1, and 12 h after operation (T2 were compared. Results: The difference of HR, BP, and PetCO2 levels before operation among the three groups was not statistically significant (P>0.05. HR, BP, and PetCO2 levels 30 min after pneumoperitoneum were significantly elevated when compared with before operation (P0.05. PetCO2 level 30 min after pneumoperitoneum in group B was significantly higher than that in group A (P0.05. Conclusions: Low pneumoperitoneum pressure has a small effect on the stress state in patients underwent gynecological laparoscopy, will not affect the surgical operation, and can obtain a preferable muscular relaxation and vision field; therefore, it can be selected in preference.

  17. Robotic distal pancreatectomy versus conventional laparoscopic distal pancreatectomy: a comparative study for short-term outcomes.

    Science.gov (United States)

    Lai, Eric C H; Tang, Chung Ngai

    2015-09-01

    Robotic system has been increasingly used in pancreatectomy. However, the effectiveness of this method remains uncertain. This study compared the surgical outcomes between robot-assisted laparoscopic distal pancreatectomy and conventional laparoscopic distal pancreatectomy. During a 15-year period, 35 patients underwent minimally invasive approach of distal pancreatectomy in our center. Seventeen of these patients had robot-assisted laparoscopic approach, and the remaining 18 had conventional laparoscopic approach. Their operative parameters and perioperative outcomes were analyzed retrospectively in a prospective database. The mean operating time in the robotic group (221.4 min) was significantly longer than that in the laparoscopic group (173.6 min) (P = 0.026). Both robotic and conventional laparoscopic groups presented no significant difference in spleen-preservation rate (52.9% vs. 38.9%) (P = 0.505), operative blood loss (100.3 ml vs. 268.3 ml) (P = 0.29), overall morbidity rate (47.1% vs. 38.9%) (P = 0.73), and post-operative hospital stay (11.4 days vs. 14.2 days) (P = 0.46). Both groups also showed no perioperative mortality. Similar outcomes were observed in robotic distal pancreatectomy and conventional laparoscopic approach. However, robotic approach tended to have the advantages of less blood loss and shorter hospital stay. Further studies are necessary to determine the clinical position of robotic distal pancreatectomy.

  18. Management of Laryngoceles by Transoral Robotic Approach.

    Science.gov (United States)

    Kayhan, Fatma Tülin; Güneş, Selçuk; Koç, Arzu Karaman; Yiğider, Ayşe Pelin; Kaya, Kamil Hakan

    2016-06-01

    Laryngoceles are air-filled sacs which communicate with the laryngeal lumen. When filled with mucus or pus, they are called laryngomucoceles and laryngopyoceles, respectively. Transoral robotic surgery (TORS) is a new and remarkable technique that expands its usefullness in otorhinolaryngology. Conventional treatments for laryngoceles were previously performed using external approaches, with aesthetically unfavorable and less function-sparing results. Transoral laser microsurgical approaches for laryngoceles were seldom reported. It is aimed to present authors' clinical experience on laryngocele management with TORS which is a rather new technique. A retrospective patient serial. Patients were evaluated for demographic data, type of lesion, reasons for hospital admittance, complaint duration, and previous surgery. Robotic surgery panel including anesthesia time, duration of surgery, need for tracheotomy, postoperative care, follow-up, and recurrence rates were also summarized. Six men (mean age 51.7 years; range 41-62) with laryngoceles underwent successful TORS. Dyspnea and hoarseness were the main complaints. Two patients had undergone previous laryngeal surgery due to laryngeal cancer, with no recurrence of malignancy at admittance for laryngocele. Three had simple laryngocele, 2 had laryngomucocele, and 1 had laryngopyocele. No laryngoceles recurred and no complication such as dysphonia or prolonged dysphagia occurred. Transoral robotic surgery was found superior in safety, technical feasibility and curative effectiveness, when compared with classical methods, especially due to absence of skin incisions. Surgical modalities for laryngocele excision should be directed toward a curative target including cosmetic and functional success, technical achievability, and surgically curative methods. Transoral robotic surgery provided all these features.

  19. Surgical Outcomes After Open, Laparoscopic, and Robotic Gastrectomy for Gastric Cancer.

    Science.gov (United States)

    Yang, Seung Yoon; Roh, Kun Ho; Kim, You-Na; Cho, Minah; Lim, Seung Hyun; Son, Taeil; Hyung, Woo Jin; Kim, Hyoung-Il

    2017-07-01

    In contrast to the significant advantages of laparoscopic versus open gastrectomy, robotic gastrectomy has shown little benefit over laparoscopic gastrectomy. This study aimed to compare multi-dimensional aspects of surgical outcomes after open, laparoscopic, and robotic gastrectomy. Data from 915 gastric cancer patients who underwent gastrectomy by one surgeon between March 2009 and May 2015 were retrospectively reviewed. Perioperative parameters were analyzed for short-term outcomes. Surgical success was defined as the absence of conversion to open surgery, major complications, readmission, positive resection margin, or fewer than 16 retrieved lymph nodes. This study investigated 241 patients undergoing open gastrectomy, 511 patients undergoing laparoscopic gastrectomy, and 173 patients undergoing robotic gastrectomy. For each approach, the respective incidences were as follows: conversion to open surgery (not applicable, 0.4%, and 0%; p = 0.444), in-hospital major complications (5.8, 2.7, and 1.2%; p = 0.020), delayed complications requiring readmission (2.9, 2.0, and 1.2%; p = 0.453), positive resection margin (1.7, 0, and 0%; p = 0.003), and inadequate number of retrieved lymph nodes (0.4, 4.1, and 1.7%; p = 0.010). Compared with open and laparoscopic surgery, robotic gastrectomy had the highest surgical success rate (90, 90.8, and 96.0%). Learning-curve analysis of success using cumulative sum plots showed success with the robotic approach from the start. Multivariate analyses identified age, sex, and gastrectomy extent as significant independent parameters affecting surgical success. Surgical approach was not a contributing factor. Open, laparoscopic, and robotic gastrectomy exhibited different incidences and causes of surgical failure. Robotic gastrectomy produced the best surgical outcomes, although the approach method itself was not an independent factor for success.

  20. Microdose flare-up vs. flexible-multidose GnRH antagonist protocols for poor responder patients who underwent ICSI.

    Science.gov (United States)

    Esinler, I

    2014-01-01

    To compare the performance of microdose flare-up (MF) and flexible-multidose gonadotropin-releasing hormone (GnRH) antagonist protocols in poor responder patients who underwent intracytoplasmic sperm injection (ICSI). One hundred and 12 consecutive patients (217 cycles) suspected to have poor ovarian response were enrolled. Group 1 (MF GnRH agonist group) constituted 64 patients (135 cycles) who underwent MF GnRH agonist protocol. Group 2 (flexible-multidose GnRH antagonist group) constituted 48 patients (82 cycles) who underwent flexible-multidose GnRH antagonist protocol. The duration of stimulation (d) (11.5 +/- 2.1 vs. 10.4 +/- 2.7, p or = seven blastomeres and < 10% fragmentation at day 3 (35.9% vs. 65.1%, p < 0.05) were significantly lower in Group 1 when compared to Group 2. The number of embryos transferred (2.2 +/- 1.3 vs. 2.4 +/- 0.9), the clinical pregnancy per embryo transfer (16.3% vs. 25.8%), and the implantation rate (8.6% vs. 12.2%) were comparable between groups. Although the flexible-multidose GnRH antagonist protocol produced better oocyte and embryo parameters, the clinical pregnancy rate and the implantation rates were comparable between the flexible-multidose GnRH antagonist and MF protocols in poor responder patients.

  1. Safety and Tolerability of Transitioning from Cangrelor to Ticagrelor in Patients Who Underwent Percutaneous Coronary Intervention.

    Science.gov (United States)

    Badreldin, Hisham A; Carter, Danielle; Cook, Bryan M; Qamar, Arman; Vaduganathan, Muthiah; Bhatt, Deepak L

    2017-08-01

    The 3 phase 3 CHAMPION (Cangrelor vs Standard Therapy to Achieve Optimal Management of Platelet Inhibition) trials collectively demonstrated the safety of transitioning from cangrelor, a potent, parenteral rapidly-acting P2Y 12 inhibitor, to clopidogrel in patients who underwent percutaneous coronary intervention (PCI). However, variation in timing of therapy, site-specific binding, and drug half-lives may theoretically complicate switching to other oral P2Y 12 inhibitors. Since regulatory approval, limited data are available regarding the "real-world" safety and tolerability of transitioning to these more potent oral P2Y 12 antagonists. From November 2015 to January 2017, we evaluated the clinical profiles and efficacy and safety outcomes in cangrelor-treated patients who underwent PCI transitioned to clopidogrel (n = 42) or ticagrelor (n = 82) at a large, tertiary care center. Most patients receiving cangrelor underwent PCI with a drug-eluting stent for acute coronary syndrome via a radial approach in the background of unfractionated heparin. Stent thrombosis within 48 hours was rare and occurred in 1 patient treated with ticagrelor. Global Use of Strategies to Open Occluded Coronary Arteries-defined bleeding occurred in 20% of patients switched to ticagrelor and 29% of patients switched to clopidogrel, but none were severe or life-threatening. In conclusion, rates of stent thrombosis and severe/life-threatening bleeding were low and comparable with those identified in the CHAMPION program, despite use of more potent oral P2Y 12 inhibition. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Sarcopenia: a new predictor of postoperative complications for elderly gastric cancer patients who underwent radical gastrectomy.

    Science.gov (United States)

    Zhou, Chong-Jun; Zhang, Feng-Min; Zhang, Fei-Yu; Yu, Zhen; Chen, Xiao-Lei; Shen, Xian; Zhuang, Cheng-Le; Chen, Xiao-Xi

    2017-05-01

    A geriatric assessment is needed to identify high-risk elderly patients with gastric cancer. However, the current geriatric assessment has been considered to be either time-consuming or subjective. The present study aimed to investigate the predictive effect of sarcopenia on the postoperative complications for elderly patients who underwent radical gastrectomy. We conducted a prospective study of patients who underwent radical gastrectomy from August 2014 to December 2015. Computed tomography-assessed lumbar skeletal muscle, handgrip strength, and gait speed were measured to define sarcopenia. Sarcopenia was present in 69 of 240 patients (28.8%) and was associated with lower body mass index, lower serum albumin, lower hemoglobin, and higher nutritional risk screening 2002 scores. Postoperative complications significantly increased in the sarcopenic patients (49.3% versus 24.6%, P sarcopenia (odds ratio: 2.959, 95% CI: 1.629-5.373, P Sarcopenia, presented as a new geriatric assessment factor, was a strong and independent risk factor for postoperative complications of elderly patients with gastric cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Impact of robotic technique and surgical volume on the cost of radical prostatectomy.

    Science.gov (United States)

    Hyams, Elias S; Mullins, Jeffrey K; Pierorazio, Phillip M; Partin, Alan W; Allaf, Mohamad E; Matlaga, Brian R

    2013-03-01

    Our present understanding of the effect of robotic surgery and surgical volume on the cost of radical prostatectomy (RP) is limited. Given the increasing pressures placed on healthcare resource utilization, such determinations of healthcare value are becoming increasingly important. Therefore, we performed a study to define the effect of robotic technology and surgical volume on the cost of RP. The state of Maryland mandates that all acute-care hospitals report encounter-level and hospital discharge data to the Health Service Cost Review Commission (HSCRC). The HSCRC was queried for men undergoing RP between 2008 and 2011 (the period during which robot-assisted laparoscopic radical prostatectomy [RALRP] was coded separately). High-volume hospitals were defined as >60 cases per year, and high-volume surgeons were defined as >40 cases per year. Multivariate regression analysis was performed to evaluate whether robotic technique and high surgical volume impacted the cost of RP. There were 1499 patients who underwent RALRP and 2565 who underwent radical retropubic prostatectomy (RRP) during the study period. The total cost for RALRP was higher than for RRP ($14,000 vs 10,100; Probotic surgery has come to dominate the healthcare marketplace, strategies to increase the role of high-volume providers may be needed to improve the cost-effectiveness of prostate cancer surgical therapy.

  4. Robotic right middle lobectomy with a subxiphoid utility port.

    Science.gov (United States)

    Jayakumar, Shruti; Nardini, Marco; Papoulidis, Pavlos; Dunning, Joel

    2018-06-01

    We present the case of a 74-year-old man with Stage IIa pulmonary adenocarcinoma, for which he underwent a robotic right middle lobectomy. A 4-armed, 5-port approach was used. Four intercostal ports were created above the ninth rib using the Cerfolio's technique. The subxiphoid port was created in the midline, 5 cm down from the xiphisternum. The robot offers higher image quality, depth perception and improved articulation of the instruments, allowing for more accurate dissection and stitching. The usage of a subxiphoid utility port reduces the clashing between instruments, offers a good angle for stapling and provides a direct view of the instruments entering into the chest. Specimen removal through the subxiphoid port may reduce postoperative pain and enhance patient recovery. The use of the subxiphoid approach as a utility port for robotic surgery is promising and may be a suitable replacement for the traditional utility port.

  5. Clinical outcomes in endometrial cancer care when the standard of care shifts from open surgery to robotics.

    Science.gov (United States)

    Mok, Zhun Wei; Yong, Eu Leong; Low, Jeffrey Jen Hui; Ng, Joseph Soon Yau

    2012-06-01

    In Singapore, the standard of care for endometrial cancer staging remains laparotomy. Since the introduction of gynecologic robotic surgery, there have been more data comparing robotic surgery to laparoscopy in the management of endometrial cancer. This study reviewed clinical outcomes in endometrial cancer in a program that moved from laparotomy to robotic surgery. A retrospective review was performed on 124 consecutive endometrial cancer patients. Preoperative data and postoperative outcomes of 34 patients undergoing robotic surgical staging were compared with 90 patients who underwent open endometrial cancer staging during the same period and in the year before the introduction of robotics. There were no significant differences in the mean age, body mass index, rates of diabetes, hypertension, previous surgery, parity, medical conditions, size of specimens, histologic type, or stage of cancer between the robotic and the open surgery groups. The first 20 robotic-assisted cases had a mean (SD) operative time of 196 (60) minutes, and the next 14 cases had a mean time of 124 (64) minutes comparable to that for open surgery. The mean number of lymph nodes retrieved during robot-assisted staging was smaller than open laparotomy in the first 20 cases but not significantly different for the subsequent 14 cases. Robot-assisted surgery was associated with lower intraoperative blood loss (110 [24] vs 250 [83] mL, P robot-assisted endometrial cancer staging after a relatively small number of cases.

  6. Prediction of Pathological Complete Response Using Endoscopic Findings and Outcomes of Patients Who Underwent Watchful Waiting After Chemoradiotherapy for Rectal Cancer.

    Science.gov (United States)

    Kawai, Kazushige; Ishihara, Soichiro; Nozawa, Hiroaki; Hata, Keisuke; Kiyomatsu, Tomomichi; Morikawa, Teppei; Fukayama, Masashi; Watanabe, Toshiaki

    2017-04-01

    Nonoperative management for patients with rectal cancer who have achieved a clinical complete response after chemoradiotherapy is becoming increasingly important in recent years. However, the definition of and modality used for patients with clinical complete response differ greatly between institutions, and the role of endoscopic assessment as a nonoperative approach has not been fully investigated. This study aimed to investigate the ability of endoscopic assessments to predict pathological regression of rectal cancer after chemoradiotherapy and the applicability of these assessments for the watchful waiting approach. This was a retrospective comparative study. This study was conducted at a single referral hospital. A total of 198 patients with rectal cancer underwent preoperative endoscopic assessments after chemoradiotherapy. Of them, 186 patients underwent radical surgery with lymph node dissection. The histopathological findings of resected tissues were compared with the preoperative endoscopic findings. Twelve patients refused radical surgery and chose watchful waiting; their outcomes were compared with the outcomes of patients who underwent radical surgery. The endoscopic criteria correlated well with tumor regression grading. The sensitivity and specificity for a pathological complete response were 65.0% to 87.1% and 39.1% to 78.3%. However, endoscopic assessment could not fully discriminate pathological complete responses, and the outcomes of patients who underwent watchful waiting were considerably poorer than the patients who underwent radical surgery. Eventually, 41.7% of the patients who underwent watchful waiting experienced uncontrollable local failure, and many of these occurrences were observed more than 3 years after chemoradiotherapy. The number of the patients treated with the watchful waiting strategy was limited, and the selection was not randomized. Although endoscopic assessment after chemoradiotherapy correlated with pathological response

  7. Robotic single-site pelvic lymphadenectomy.

    Science.gov (United States)

    Tateo, Saverio; Nozza, Arrigo; Del Pezzo, Chiara; Mereu, Liliana

    2014-09-01

    To examine the feasibility of performing pelvic lymphadenectomy with robotic single site approach. Recent papers described the feasibility of robotic-single site hysterectomy [1-3] for benign and malign pathologies but only with the development of new single site 5mm instruments as the bipolar forceps, robotic single site platform can be safely utilized also for lymphadenectomy. A 65 year-old, multiparous patient with a body mass index of 22.5 and diagnosed with well differentiated adenocarcinoma of the endometrium underwent a robotic single-site peritoneal washing, total hysterectomy, bilateral adnexectomy and pelvic lymphadenectomy. The procedure was performed using the da Vinci Si Surgical System (Intuitive Surgical, Sunnyvale, CA) through a single 2,5 cm umbilical incision, with a multi-channel system and two single site robotic 5mm instruments. A 3-dimensional, HD 8.5mm endoscope and a 5mm accessory instrument were also utilized. Type I lymphonodes dissection for external iliac and obturator regions was performed [4]. Total operative time was 210 min; incision, trocar placement and docking time occurring in 12 min. Total console time was 183 min, estimated blood loss was 50 ml, no intra-operative or post-operative complications occurred. Hospital discharge occurred on post operative day 2 and total number of lymphnodes removed was 33. Difficulties in term of instrument's clashing and awkward motions have been encountered. Robotic single-site pelvic lymphadenectomy using bipolar forceps and monopolar hook is feasible. New developments are needed to improve surgical ergonomics and additional studies should be performed to explore possible benefits of this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Robotic-assisted vesicovaginal fistula repair using an extravesical approach without interposition grafting.

    Science.gov (United States)

    Kelly, Erin; Wu, Maria Y; MacMillan, J Barry

    2018-03-01

    Post-hysterectomy vesicovaginal fistula (VVF) is rare. In addition to conventional abdominal and vaginal approaches, robotic-assisted VVF repairs have recently been described. We present a case of an extravesical, robotic-assisted VVF repair, without placement of an interposition graft performed in a Canadian teaching center. A 51-year-old woman presented with urinary incontinence 5 days after laparoscopic hysterectomy. Computed tomography cystogram, cystoscopy, and methylene blue dye test, confirmed a VVF above the bladder trigone. The patient underwent a robotic-assisted VVF repair 3 months after presentation, without complication. An abdominal, extravesical approach was used. Operative time was 116 min and repeat CT cystogram showed no evidence of persistent. We have demonstrated that a VVF repair, using a robotic-assisted, extravesical approach without interposition graft placement, can be safe, less invasive and have a successful outcome at 1 year of follow-up.

  9. A comparative study of erectile function and use of erectile aids in high-risk prostate cancer patients after robot-assisted laparoscopic prostatectomy

    DEFF Research Database (Denmark)

    Østby-Deglum, Marie; Brennhovd, B.; Axcrona, K.

    2015-01-01

    Objective. Erectile function with and without use of erectile aids was compared in high-, intermediate- and low-risk prostate cancer patients at a mean of 3 years after robot-assisted laparoscopic prostatectomy (RALP). Materials and methods. A sample of 982 men who underwent RALP at Oslo University...... according to the preoperative D'Amico classification. Based on questionnaire data, two primary outcomes were defined: ability to have intercourse (sufficient erection), and use and effect of erectile aids. Results. Sufficient erection with or without erectile aids was reported by 19% of the high-, 30...

  10. Experiences with an application of industrial robotics for accurate patient positioning in proton radiotherapy.

    Science.gov (United States)

    Allgower, C E; Schreuder, A N; Farr, J B; Mascia, A E

    2007-03-01

    Protons beams deliver targeted radiation doses with greater precision than is possible with electrons or megavoltage X-ray photons, but to retain this advantage, patient positioning systems at proton clinics must meet tighter accuracy requirements. For this and other reasons, robots were incorporated into the treatment room systems at MPRI. The Midwest Proton Radiotherapy Institute (MPRI) is the first radiotherapy facility in the United States to use commercial robots with six degrees of freedom for patient positioning, rather than a traditional bed with four degrees of freedom. This paper outlines the ways in which robots are used at MPRI and attempts to distil insights from the experience of treating over 200 radiotherapy patients with a robotic system from February 2004 to late 2006. The system has performed well, and with great reliability, but there is room for future improvement, especially in ease of use and in reducing the time to get patients into position. Copyright 2006 John Wiley & Sons, Ltd.

  11. Robotic Y-V Plasty for Recalcitrant Bladder Neck Contracture.

    Science.gov (United States)

    Granieri, Michael A; Weinberg, Aaron C; Sun, Jeffrey Y; Stifleman, Michael; Zhao, Lee

    2018-07-01

    To demonstrate the technique and the outcomes of robot assisted Y-V plasty bladder neck reconstruction (RYVBNR). We present our technique for treatment of recalcitrant bladder neck contracture (BNC) in 7 patients who underwent RYVBNR at our institution between March 2016 and September 2017. Indication for the procedure was incomplete emptying, recurrent urinary tract infections, and dysuria. On follow-up, patients were assessed for clinical success by absence of infections, symptoms, and cystoscopic evaluation. Robotic assisted dissection is performed to open the space of Retzius and mobilize the bladder. The cystoscope is passed to the level of the BNC, and Firefly technology is used to localize the BNC. The BNC is incised anteriorly, and a V-shaped bladder flap is advanced into the BNC in a Y-V plasty fashion. We place a perioperative closed suction drain, which is removed before discharge, and a 22 Fr catheter, which that will be removed in the office at approximately 2 weeks. Six men developed recalcitrant BNCs and 1 developed a recalcitrant vesicourethral anastomotic stenosis. All patients had previously undergone an endoscopic procedure. Median time for last attempt at endoscopic management to robot-assisted bladder neck repair was 4.7 months. The average number of prior attempts at endoscopic management was 2. All patients underwent RYVBNR without conversion to open surgery. The median operative time was 240 minutes, estimated blood loss was 67 mL, and length of stay was 1 day. There were no intraoperative complications. Catheters were removed in the office at a median time of 15 days. At a median follow-up of 8 months, all cases were successful with no evidence of recurrence. Only 2 patients had persistent urinary incontinence at 1 pad per day. RYVBNR with a Y-V plasty is a feasible and effective technique for managing a difficult reconstructive problem. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Total robotic radical rectal resection with da Vinci Xi system: single docking, single phase technique.

    Science.gov (United States)

    Tamhankar, Anup Sunil; Jatal, Sudhir; Saklani, Avanish

    2016-12-01

    This study aims to assess the advantages of Da Vinci Xi system in rectal cancer surgery. It also assesses the initial oncological outcomes after rectal resection with this system from a tertiary cancer center in India. Robotic rectal surgery has distinct advantages over laparoscopy. Total robotic resection is increasing following the evolution of hybrid technology. The latest Da Vinci Xi system (Intuitive Surgical, Sunnyvale, USA) is enabled with newer features to make total robotic resection possible with single docking and single phase. Thirty-six patients underwent total robotic resection in a single phase and single docking. We used newer port positions in a straight line. Median distance from the anal verge was 4.5 cm. Median robotic docking time and robotic procedure time were 9 and 280 min, respectively. Median blood loss was 100 mL. One patient needed conversion to an open approach due to advanced disease. Circumferential resection margin and longitudinal resection margins were uninvolved in all other patients. Median lymph node yield was 10. Median post-operative stay was 7 days. There were no intra-operative adverse events. The latest Da Vinci Xi system has made total robotic rectal surgery feasible in single docking and single phase. With the new system, four arm total robotic rectal surgery may replace the hybrid technique of laparoscopic and robotic surgery for rectal malignancies. The learning curve for the new system appears to be shorter than anticipated. Early perioperative and oncological outcomes of total robotic rectal surgery with the new system are promising. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Robotic Enucleation for Benign or Borderline Tumours of the Pancreas: A Retrospective Analysis and Comparison from a High-Volume Centre in Asia.

    Science.gov (United States)

    Jin, Jia-Bin; Qin, Kai; Li, Hua; Wu, Zhi-Chong; Zhan, Qian; Deng, Xia-Xing; Chen, Hao; Shen, Bai-Yong; Peng, Cheng-Hong; Li, Hong-Wei

    2016-12-01

    Enucleation is increasingly performed for benign or borderline tumours of the pancreas because it is a parenchyma-sparing and less invasive procedure compared to conventional pancreatectomy, which reduces the risk of exocrine and endocrine insufficiency. This study retrospectively evaluated and compared the pre-, intra-, and post-operative clinical characteristics after open and robotic approaches for pancreatic enucleation. Fifty-six cases of enucleation for benign or borderline tumours of the pancreas treated from March 2010 to July 2015 were identified by a retrospective search. These included 25 patients who underwent an open approach and 31 patients who underwent a robotic approach. The clinical characteristics were extracted and compared. The two groups had a similar location and pathology of the tumour. The robotic group had a significantly shorter operation time and significantly less blood loss than the open group. The rates of clinical pancreatic fistula (PF) formation and major complications were similar. The robotic approach could be applied for a tumour on the right side of the pancreas without increasing the incidence of clinical PF or other major complications. The patients with clinical PF had a significantly shorter distance between the lesion and the main pancreatic duct (MPD). Robotic enucleation appears to be a feasible and safe approach for benign or borderline tumours of the pancreas and was associated with similarly favourable surgical outcomes as the open approach. Identifying and avoiding the MPD is an important step during enucleation.

  14. Impact of metabolic syndrome on early recovery of continence after robot-assisted radical prostatectomy.

    Science.gov (United States)

    Nishikawa, Masatomo; Watanabe, Hiromitsu; Kurahashi, Toshifumi

    2017-09-01

    To evaluate the impact of metabolic syndrome on the early recovery of urinary continence after robot-assisted radical prostatectomy. The present study included a total of 302 consecutive Japanese patients with clinically localized prostate cancer who underwent robot-assisted radical prostatectomy. In this study, postoperative urinary continence was defined as no leak or the use of a security pad. The continence status was assessed by interviews before and 1 and 3 months after robot-assisted radical prostatectomy. Metabolic syndrome was defined as follows: body mass index ≥25 kg/m 2 and two or more of the following: hypertension, diabetes mellitus and dyslipidemia. The effect of the presence of metabolic syndrome on the continence status of these patients was retrospectively examined. A total of 116 (38.4%) and 203 (67.2%) of the 302 patients were continent at 1 and 3 months after robot-assisted radical prostatectomy, respectively. A total of 31 (10.3%) patients were judged to have metabolic syndrome. Despite the operative time being longer in patients with metabolic syndrome, no significant differences were observed in the remaining preoperative, intraoperative or postoperative variables between patients with or without metabolic syndrome. On multivariate logistic regression analysis, metabolic syndrome and the duration of hospitalization were significantly correlated with the 1-month continence status. Similarly, metabolic syndrome and estimated blood loss during surgery were independent predictors of continence rates at 3 months after robot-assisted radical prostatectomy. These findings suggest that the presence of metabolic syndrome could have a significant impact on the early recovery of urinary continence after robot-assisted radical prostatectomy. © 2017 The Japanese Urological Association.

  15. Risk of port-site metastases in pelvic cancers after robotic surgery.

    Science.gov (United States)

    Seror, J; Bats, A-S; Bensaïd, C; Douay-Hauser, N; Ngo, C; Lécuru, F

    2015-04-01

    To assess the risk of occurrence of port-site metastases after robotic surgery for pelvic cancer. Retrospective study from June 2007 to March 2013 of patients with gynecologic cancer who underwent robot-assisted surgery. We collected preoperative data, including characteristics of patients and FIGO stage, intraoperative data (surgery performed, number of ports), and postoperative data (occurrence of metastases, occurrence of port-site metastases). 115 patients were included in the study: 61 with endometrial cancer, 50 with cervical cancer and 4 with ovarian cancer. The surgical procedures performed were: hysterectomy with bilateral salpingo-oophorectomy, radical hysterectomy, pelvic lymphadenectomy, para-aortic lymphadenectomy and omentectomy. All surgical procedures required the introduction of 4 ports, 3 for the robot and 1 for the assistant. With a mean follow-up of 504.4 days (507.7 days for endometrial cancer, 479.5 days for cervical cancer, and 511.3 for ovarian cancer), we observed 9 recurrences but no port-site metastasis. No port-site metastasis has occurred in our series. However, larger, prospective and randomized works are needed to formally conclude. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Early results of robotically assisted mitral valve surgery: Analysis of the first 1000 cases.

    Science.gov (United States)

    Gillinov, A Marc; Mihaljevic, Tomislav; Javadikasgari, Hoda; Suri, Rakesh M; Mick, Stephanie L; Navia, José L; Desai, Milind Y; Bonatti, Johannes; Khosravi, Mitra; Idrees, Jay J; Lowry, Ashley M; Blackstone, Eugene H; Svensson, Lars G

    2018-01-01

    The study objective was to assess the technical and process improvement and clinical outcomes of robotic mitral valve surgery by examining the first 1000 cases performed in a tertiary care center. We reviewed the first 1000 patients (mean age, 56 ± 10 years) undergoing robotic primary mitral valve surgery, including concomitant procedures (n = 185), from January 2006 to November 2013. Mitral valve disease cause was degenerative (n = 960, 96%), endocarditis (n = 26, 2.6%), rheumatic (n = 10, 1.0%), ischemic (n = 3, 0.3%), and fibroelastoma (n = 1, 0.1%). All procedures were performed via right chest access with femoral perfusion for cardiopulmonary bypass. Mitral valve repair was attempted in 997 patients (2 planned replacements and 1 resection of fibroelastoma), 992 (99.5%) of whom underwent valve repair, and 5 (0.5%) of whom underwent valve replacement. Intraoperative postrepair echocardiography showed that 99.7% of patients receiving repair (989/992) left the operating room with no or mild mitral regurgitation, and predischarge echocardiography showed that mitral regurgitation remained mild or less in 97.9% of patients (915/935). There was 1 hospital death (0.1%), and 14 patients (1.4%) experienced a stroke; stroke risk declined from 2% in the first 500 patients to 0.8% in the second 500 patients. Over the course of the experience, myocardial ischemic and cardiopulmonary bypass times (P < .0001), transfusion (P = .003), and intensive care unit and postoperative lengths of stay (P < .05) decreased. Robotic mitral valve surgery is associated with a high likelihood of valve repair and low operative mortality and morbidity. The combination of algorithm-driven patient selection and increased experience enhanced clinical outcomes and procedural efficiency. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  17. The impact of marketing language on patient preference for robot-assisted surgery.

    Science.gov (United States)

    Dixon, Peter R; Grant, Robert C; Urbach, David R

    2015-02-01

    Robot-assisted surgery is gaining momentum as a new trend in minimally invasive surgery. With limited evidence supporting its use in place of the far less expensive conventional laparoscopic surgery, it has been suggested that marketing pressure is partly responsible for its widespread adoption. The impact of phrases that promote the novelty of robot-assisted surgery on patient decision making has not been investigated. We conducted a discrete choice experiment to elicit preference of partial colectomy technique for a hypothetical diagnosis of colon cancer. A convenience sample of 38 participants in an ambulatory general surgery clinic consented to participate. Each participant made 2 treatment decisions between robot-assisted surgery and conventional laparoscopic surgery, with robot-assisted surgery described as "innovative" and "state-of-the-art" in one of the decisions (marketing frame), and by a disclosure of the uncertainty of available evidence in the other (evidence-based frame). The magnitude of the framing effect was large with 12 of 38 subjects (31.6%, P = .005) selecting robot-assisted surgery in the marketing frame and not the evidence-based frame. This is the first study to our knowledge to demonstrate that words that highlight novelty have an important influence on patient preference for robot-assisted surgery and that use of more neutral language can mitigate this effect. © The Author(s) 2014.

  18. Diffusion of robotics into clinical practice in the United States: process, patient safety, learning curves, and the public health.

    Science.gov (United States)

    Mirheydar, Hossein S; Parsons, J Kellogg

    2013-06-01

    Robotic technology disseminated into urological practice without robust comparative effectiveness data. To review the diffusion of robotic surgery into urological practice. We performed a comprehensive literature review focusing on diffusion patterns, patient safety, learning curves, and comparative costs for robotic radical prostatectomy, partial nephrectomy, and radical cystectomy. Robotic urologic surgery diffused in patterns typical of novel technology spreading among practicing surgeons. Robust evidence-based data comparing outcomes of robotic to open surgery were sparse. Although initial Level 3 evidence for robotic prostatectomy observed complication outcomes similar to open prostatectomy, subsequent population-based Level 2 evidence noted an increased prevalence of adverse patient safety events and genitourinary complications among robotic patients during the early years of diffusion. Level 2 evidence indicated comparable to improved patient safety outcomes for robotic compared to open partial nephrectomy and cystectomy. Learning curve recommendations for robotic urologic surgery have drawn exclusively on Level 4 evidence and subjective, non-validated metrics. The minimum number of cases required to achieve competency for robotic prostatectomy has increased to unrealistically high levels. Most comparative cost-analyses have demonstrated that robotic surgery is significantly more expensive than open or laparoscopic surgery. Evidence-based data are limited but suggest an increased prevalence of adverse patient safety events for robotic prostatectomy early in the national diffusion period. Learning curves for robotic urologic surgery are subjective and based on non-validated metrics. The urological community should develop rigorous, evidence-based processes by which future technological innovations may diffuse in an organized and safe manner.

  19. Contemporary open and robotic radical prostatectomy practice patterns among urologists in the United States.

    Science.gov (United States)

    Lowrance, William T; Eastham, James A; Savage, Caroline; Maschino, A C; Laudone, Vincent P; Dechet, Christopher B; Stephenson, Robert A; Scardino, Peter T; Sandhu, Jaspreet S

    2012-06-01

    We describe current trends in robotic and open radical prostatectomy in the United States after examining case logs for American Board of Urology certification. American urologists submit case logs for initial board certification and recertification. We analyzed logs from 2004 to 2010 for trends and used logistic regression to assess the impact of urologist age on robotic radical prostatectomy use. A total of 4,709 urologists submitted case logs for certification between 2004 and 2010. Of these logs 3,374 included 1 or more radical prostatectomy cases. Of the urologists 2,413 (72%) reported performing open radical prostatectomy only while 961 (28%) reported 1 or more robotic radical prostatectomies and 308 (9%) reported robotic radical prostatectomy only. During this 7-year period we observed a large increase in the number of urologists who performed robotic radical prostatectomy and a smaller corresponding decrease in those who performed open radical prostatectomy. Only 8% of patients were treated with robotic radical prostatectomy by urologists who were certified in 2004 while 67% underwent that procedure in 2010. Median age of urologists who exclusively performed open radical prostatectomy was 43 years (IQR 38-51) vs 41 (IQR 35-46) for those who performed only robotic radical prostatectomy. While the rate was not as high as the greater than 85% industry estimate, 67% of radical prostatectomies were done robotically among urologists who underwent board certification or recertification in 2010. Total radical prostatectomy volume almost doubled during the study period. These data provide nonindustry based estimates of current radical prostatectomy practice patterns and further our understanding of the evolving surgical treatment of prostate cancer. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Clinical outcomes for 14 consecutive patients with solid pseudopapillary neoplasms who underwent laparoscopic distal pancreatectomy.

    Science.gov (United States)

    Nakamura, Yoshiharu; Matsushita, Akira; Katsuno, Akira; Yamahatsu, Kazuya; Sumiyoshi, Hiroki; Mizuguchi, Yoshiaki; Uchida, Eiji

    2016-02-01

    The postoperative results of laparoscopic distal pancreatectomy for solid pseudopapillary neoplasm of the pancreas (SPN), including the effects of spleen-preserving resection, are still to be elucidated. Of the 139 patients who underwent laparoscopic pancreatectomy for non-cancerous tumors, 14 consecutive patients (average age, 29.6 years; 1 man, 13 women) with solitary SPN who underwent laparoscopic distal pancreatectomy between March 2004 and June 2015 were enrolled. The tumors had a mean diameter of 4.8 cm. Laparoscopic spleen-preserving distal pancreatectomy was performed in eight patients (spleen-preserving group), including two cases involving pancreatic tail preservation, and laparoscopic spleno-distal pancreatectomy was performed in six patients (standard resection group). The median operating time was 317 min, and the median blood loss was 50 mL. Postoperatively, grade B pancreatic fistulas appeared in two patients (14.3%) but resolved with conservative treatment. No patients had postoperative complications, other than pancreatic fistulas, or required reoperation. The median postoperative hospital stay was 11 days, and the postoperative mortality was zero.None of the patients had positive surgical margins or lymph nodes with metastasis. The median follow-up period did not significantly differ between the two groups (20 vs 39 months, P = 0.1368). All of the patients are alive and free from recurrent tumors without major late-phase complications. Laparoscopic distal pancreatectomy might be a suitable treatment for patients with SPN. A spleen-preserving operation is preferable for younger patients with SPN, and this study demonstrated the non-inferiority of the procedure compared to spleno-distal pancreatectomy. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  1. Robotic Assisted Simple Prostatectomy versus Holmium Laser Enucleation of the Prostate for Lower Urinary Tract Symptoms in Patients with Large Volume Prostate: A Comparative Analysis from a High Volume Center.

    Science.gov (United States)

    Umari, Paolo; Fossati, Nicola; Gandaglia, Giorgio; Pokorny, Morgan; De Groote, Ruben; Geurts, Nicolas; Goossens, Marijn; Schatterman, Peter; De Naeyer, Geert; Mottrie, Alexandre

    2017-04-01

    We report a comparative analysis of robotic assisted simple prostatectomy vs holmium laser enucleation of the prostate in patients who had benign prostatic hyperplasia with a large volume prostate (greater than 100 ml). A total of 81 patients underwent robotic assisted simple prostatectomy and 45 underwent holmium laser enucleation of the prostate in a 7-year period. Patients were preoperatively assessed with transrectal ultrasound and uroflowmetry. Functional parameters were assessed postoperatively during followup. Perioperative outcomes included operative time, postoperative hemoglobin, catheterization time and hospitalization. Complications were reported according to the Clavien-Dindo classification. Compared to the holmium laser enucleation group, patients treated with prostatectomy were significantly younger (median age 69 vs 74 years, p = 0.032) and less healthy (Charlson comorbidity index 2 or greater in 62% vs 29%, p = 0.0003), and had a lower rate of suprapubic catheterization (23% vs 42%, p = 0.028) and a higher preoperative I-PSS (International Prostate Symptom Score) (25 vs 21, p = 0.049). Both groups showed an improvement in the maximum flow rate (15 vs 11 ml per second, p = 0.7), and a significant reduction in post-void residual urine (-73 vs -100 ml, p = 0.4) and I-PSS (-20 vs -18, p = 0.8). Median operative time (105 vs 105 minutes, p = 0.9) and postoperative hemoglobin (13.2 vs 13.8 gm/dl, p = 0.08) were similar for robotic assisted prostatectomy and holmium laser enucleation, respectively. Median catheterization time (3 vs 2 days, p = 0.005) and median hospitalization (4 vs 2 days, p = 0.0001) were slightly shorter in the holmium laser group. Complication rates were similar with no Clavien grade greater than 3 in either group. Our results from a single center suggest comparable outcomes for robotic assisted simple prostatectomy and holmium laser enucleation of the prostate in patients with a large volume prostate. These findings require

  2. Learning curve for robotic-assisted surgery for rectal cancer: use of the cumulative sum method.

    Science.gov (United States)

    Yamaguchi, Tomohiro; Kinugasa, Yusuke; Shiomi, Akio; Sato, Sumito; Yamakawa, Yushi; Kagawa, Hiroyasu; Tomioka, Hiroyuki; Mori, Keita

    2015-07-01

    Few data are available to assess the learning curve for robotic-assisted surgery for rectal cancer. The aim of the present study was to evaluate the learning curve for robotic-assisted surgery for rectal cancer by a surgeon at a single institute. From December 2011 to August 2013, a total of 80 consecutive patients who underwent robotic-assisted surgery for rectal cancer performed by the same surgeon were included in this study. The learning curve was analyzed using the cumulative sum method. This method was used for all 80 cases, taking into account operative time. Operative procedures included anterior resections in 6 patients, low anterior resections in 46 patients, intersphincteric resections in 22 patients, and abdominoperineal resections in 6 patients. Lateral lymph node dissection was performed in 28 patients. Median operative time was 280 min (range 135-683 min), and median blood loss was 17 mL (range 0-690 mL). No postoperative complications of Clavien-Dindo classification Grade III or IV were encountered. We arranged operative times and calculated cumulative sum values, allowing differentiation of three phases: phase I, Cases 1-25; phase II, Cases 26-50; and phase III, Cases 51-80. Our data suggested three phases of the learning curve in robotic-assisted surgery for rectal cancer. The first 25 cases formed the learning phase.

  3. Safety and feasibility of the robotic platform in the management of surgical sequelae of chronic pancreatitis.

    Science.gov (United States)

    Hamad, Ahmad; Zenati, Mazen S; Nguyen, Trang K; Hogg, Melissa E; Zeh, Herbert J; Zureikat, Amer H

    2018-02-01

    The application of minimally invasive surgery to chronic pancreatitis (CP) procedures is uncommon. Our objective was to report the safety and feasibility of the robotic approach in the treatment of surgical sequelae of CP, and provide insights into the technique, tricks, and pitfalls associated with the application of robotics to this challenging disease entity. A retrospective review of a prospectively maintained database of patients undergoing robotic-assisted resections and/or drainage procedures for CP at the University of Pittsburgh between May 2009 and January 2017 was performed. A video of a robotic Frey procedure is also shown. Of 812 robotic pancreatic resections and reconstructions 39 were for CP indications. These included 11 total pancreatectomies [with and without auto islet transplantation], 8 Puestow procedures, 4 Frey procedures, 6 pancreaticoduodenectomies, and 10 distal pancreatectomies. Median age was 49, and 41% of the patients were female. The most common etiology for CP was idiopathic pancreatitis (n = 16, 46%). Median operative time was 324 min with a median estimated blood loss of 250 ml. None of the patients required conversion to laparotomy. A Clavien III-IV complication rate was experienced by 5 (13%) patients, including one reoperation. Excluding the eleven patients who underwent TP, rate of clinically relevant postoperative pancreatic fistula was 7% (Grade B = 2, Grade C = 0). No 30 or 90 day mortalities were recorded. The median length of hospital stay was 7 days. Use of the robotic platform is safe and feasible when tackling complex pancreatic resections for sequelae of chronic pancreatitis.

  4. Functional results of robotic total intersphincteric resection with hand-sewn coloanal anastomosis.

    Science.gov (United States)

    Luca, F; Valvo, M; Guerra-Cogorno, M; Simo, D; Blesa-Sierra, E; Biffi, R; Garberoglio, C

    2016-06-01

    In recent decades there has been an increasing trend toward sphincter-preserving procedures for the treatment of low rectal cancer. Robotic surgery is considered to be particularly beneficial when operating in the deep pelvis, where laparoscopy presents technical limitations. The aim of this study was to prospectively evaluate the functional outcomes in patients affected by rectal cancer after robotic total intersphincteric resection (ISR) with hand-sewn coloanal anastomosis. From March 2008 to October 2012, 23 consecutive patients affected by distal rectal adenocarcinoma underwent robotic ISR. Operative, clinical, pathological and functional data regarding continence or presence of a low anterior resection syndrome (LARS) were prospectively collected in a database. Twenty-three consecutive patients were included in the study: 8 men and 15 women. The mean age was 60.2 years (range 28-73). Eighteen (78.3%) had neoadjuvant radiochemotherapy. Conversion rate was nil. The mean operative time was 296.01 min and the mean postoperative hospital stay was 7.43 ± 1.73 days. According to Kirwan's incontinence score, good fecal continence was shown in 85.7% of patients (Grade 1 and 2) and none required a colostomy (Grade 4). Concerning LARS score, the results were as follows: 57.1% patients had no LARS; 19% minor LARS and 23.8% major LARS. Robotic total ISR for low rectal cancer is an acceptable alternative to traditional procedures. Extensive discussion with the patient about the risk of poor functional outcomes or LARS syndrome is mandatory when considering an ISR for treatment of low rectal cancer. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Controlling patient participation during robot-assisted gait training

    Science.gov (United States)

    2011-01-01

    Background The overall goal of this paper was to investigate approaches to controlling active participation in stroke patients during robot-assisted gait therapy. Although active physical participation during gait rehabilitation after stroke was shown to improve therapy outcome, some patients can behave passively during rehabilitation, not maximally benefiting from the gait training. Up to now, there has not been an effective method for forcing patient activity to the desired level that would most benefit stroke patients with a broad variety of cognitive and biomechanical impairments. Methods Patient activity was quantified in two ways: by heart rate (HR), a physiological parameter that reflected physical effort during body weight supported treadmill training, and by a weighted sum of the interaction torques (WIT) between robot and patient, recorded from hip and knee joints of both legs. We recorded data in three experiments, each with five stroke patients, and controlled HR and WIT to a desired temporal profile. Depending on the patient's cognitive capabilities, two different approaches were taken: either by allowing voluntary patient effort via visual instructions or by forcing the patient to vary physical effort by adapting the treadmill speed. Results We successfully controlled patient activity quantified by WIT and by HR to a desired level. The setup was thereby individually adaptable to the specific cognitive and biomechanical needs of each patient. Conclusion Based on the three successful approaches to controlling patient participation, we propose a metric which enables clinicians to select the best strategy for each patient, according to the patient's physical and cognitive capabilities. Our framework will enable therapists to challenge the patient to more activity by automatically controlling the patient effort to a desired level. We expect that the increase in activity will lead to improved rehabilitation outcome. PMID:21429200

  6. The Demographics of Patients with Skin Cancer who Underwent Surgery in Diyarbakır and Performed Surgical Techniques

    Directory of Open Access Journals (Sweden)

    Burhan Özalp

    2018-06-01

    Full Text Available Objective: The major factor for developing malignant skin cancers is sunlight exposure. This study aimed to evaluate the demographics of patients with skin cancers who underwent surgery in Diyarbakır where the population is exposed to more sunlight than most other Turkish cities. Methods: The medical records of patients who underwent surgery for malignant skin cancer excision between 2011 and 2016 were searched using University Hospital’s patient database program. Data about patients’ demographics, cancer features, and the surgical techniques performed were collected. Results: Over a 5-year period, 190 patients underwent surgical excision. The male to female ratio was 1.56, and the mean age was 65.8 ± 15.7 (range, 20-94 years. The most common skin cancer was basal cell carcinoma (n=138, 72.7%, followed by squamous cell carcinoma (n=45, 23.7% and malignant melanoma (n=5, 2.6%. The most common surgery was primary excision, which was performed in 90 of 190 patients (47.36%; tissue reconstruction with a skin graft or flap surgery was required for the remaining 100 (52.63%, showing a significant difference (p<0.001. Conclusion: Basal cell carcinoma is the most common skin cancer, and less than half of the patients sought treatment immediately after they recognized the lesion. The public should be educated about skin cancers to increase early diagnosis and encourage timely treatment, thereby decreasing morbidity and mortality from skin cancer.

  7. Robotic assisted surgery in pediatric gynecology: promising innovation in mini invasive surgical procedures.

    Science.gov (United States)

    Nakib, Ghassan; Calcaterra, Valeria; Scorletti, Federico; Romano, Piero; Goruppi, Ilaria; Mencherini, Simonetta; Avolio, Luigi; Pelizzo, Gloria

    2013-02-01

    Robotic assisted surgery is not yet widely applied in the pediatric field. We report our initial experience regarding the feasibility, safety, benefits, and limitations of robot-assisted surgery in pediatric gynecological patients. Descriptive, retrospective report of experience with pediatric gynecological patients over a period of 12 months. Department of Pediatric Surgery, IRCCS Policlinico San Matteo Foundation. Children and adolescents, with a surgical diagnosis of ovarian and/or tubal lesions. Robot assembly time and operative time, days of hospitalization, time to cessation of pain medication, complication rate, conversion rate to laparoscopic procedure and trocar insertion strategy. Six children and adolescents (2.4-15 yrs), weighing 12-55 kg, underwent robotic assisted surgery for adnexal pathologies: 2 for ovarian cystectomy, 2 for oophorectomy, 1 for right oophorectomy and left salpingo-oophorectomy for gonadal disgenesis, 1 for exploration for suspected pelvic malformation. Mean operative time was 117.5 ± 34.9 minutes. Conversion to laparatomy was not necessary in any of the cases. No intra- or postoperative complications occurred. Initial results indicate that robotic assisted surgery is safely applicable in the pediatric gynecological population, although it is still premature to conclude that it provides better clinical outcomes than traditional laparoscopic surgery. Randomized, prospective, comparative studies will help characterize the advantages and disadvantages of this new technology in pediatric patients. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  8. Financial Impact of the Robotic Approach in Liver Surgery: A Comparative Study of Clinical Outcomes and Costs Between the Robotic and Open Technique in a Single Institution.

    Science.gov (United States)

    Daskalaki, Despoina; Gonzalez-Heredia, Raquel; Brown, Marc; Bianco, Francesco M; Tzvetanov, Ivo; Davis, Myriam; Kim, Jihun; Benedetti, Enrico; Giulianotti, Pier C

    2017-04-01

    One of the perceived major drawbacks of minimally invasive techniques has always been its cost. This is especially true for the robotic approach and is one of the main reasons that has prevented its wider acceptance among hospitals and surgeons. The aim of our study was to evaluate the clinical outcomes and economic impact of robotic and open liver surgery in a single institution. Sixty-eight robotic and 55 open hepatectomies were performed at our institution between January 1, 2009 and December 31, 2013. Demographics, perioperative data, and postoperative outcomes were collected and compared between the two groups. An independent company performed the financial analysis. The economic parameters comprised direct variable costs, direct fixed costs, and indirect costs. Mean estimated blood loss was significantly less in the robotic group (438 versus 727.8 mL; P = .038). Overall morbidity was significantly lower in the robotic group (22% versus 40%; P = .047). Clavien III/IV complications were also lower, with 4.4% in the robotic versus 16.3% in the open group (P = .043). The length of stay in the intensive care unit (ICU) was shorter for patients who underwent a robotic procedure (2.1 versus 3.3 days; P = .004). The average total cost, including readmissions, was $37,518 for robotic surgery and $41,948 for open technique. Robotic liver resections had less overall morbidity, ICU, and hospital stay. This translates into decreased average costs for robotic surgery. These procedures are financially comparable to open resections and do not represent a financial burden to the hospital.

  9. Application of the statistical process control method for prospective patient safety monitoring during the learning phase: robotic kidney transplantation with regional hypothermia (IDEAL phase 2a-b).

    Science.gov (United States)

    Sood, Akshay; Ghani, Khurshid R; Ahlawat, Rajesh; Modi, Pranjal; Abaza, Ronney; Jeong, Wooju; Sammon, Jesse D; Diaz, Mireya; Kher, Vijay; Menon, Mani; Bhandari, Mahendra

    2014-08-01

    Traditional evaluation of the learning curve (LC) of an operation has been retrospective. Furthermore, LC analysis does not permit patient safety monitoring. To prospectively monitor patient safety during the learning phase of robotic kidney transplantation (RKT) and determine when it could be considered learned using the techniques of statistical process control (SPC). From January through May 2013, 41 patients with end-stage renal disease underwent RKT with regional hypothermia at one of two tertiary referral centers adopting RKT. Transplant recipients were classified into three groups based on the robotic training and kidney transplant experience of the surgeons: group 1, robot trained with limited kidney transplant experience (n=7); group 2, robot trained and kidney transplant experienced (n=20); and group 3, kidney transplant experienced with limited robot training (n=14). We employed prospective monitoring using SPC techniques, including cumulative summation (CUSUM) and Shewhart control charts, to perform LC analysis and patient safety monitoring, respectively. Outcomes assessed included post-transplant graft function and measures of surgical process (anastomotic and ischemic times). CUSUM and Shewhart control charts are time trend analytic techniques that allow comparative assessment of outcomes following a new intervention (RKT) relative to those achieved with established techniques (open kidney transplant; target value) in a prospective fashion. CUSUM analysis revealed an initial learning phase for group 3, whereas groups 1 and 2 had no to minimal learning time. The learning phase for group 3 varied depending on the parameter assessed. Shewhart control charts demonstrated no compromise in functional outcomes for groups 1 and 2. Graft function was compromised in one patient in group 3 (pcontrol chart analytic techniques. These methods allow determination of the duration of mentorship and identification of adverse events in a timely manner. A new operation

  10. [Robot-Assisted Laparoscopic Radical Prostatectomy for Patients with Prostatic Cancer and Factors Promoting Installation of the Robotic Surgical Equipment-Questionnaire Survey].

    Science.gov (United States)

    Tsukamoto, Taiji; Tanaka, Shigeru

    2015-08-01

    We conducted a questionnaire survey of hospitals with robot-assisted surgical equipment to study changes of the surgical case loads after its installation and the managerial strategies for its purchase. The study included 154 hospitals (as of April 2014) that were queried about their radical prostatectomy case loads from January 2009 to December 2013, strategies for installation of the equipment in their hospitals, and other topics related to the study purpose. The overall response rate of hospitals was 63%, though it marginally varied according to type and area. The annual case load was determined based on the results of the questionnaire and other modalities. It increased from 3,518 in 2009 to 6,425 in 2013. The case load seemed to be concentrated in hospitals with robot equipment since the increase of their number was very minimal over the 5 years. The hospitals with the robot treated a larger number of newly diagnosed patients with the disease than before. Most of the patients were those having localized cancer that was indicated for radical surgery, suggesting again the concentration of the surgical case loads in the hospitals with robots. While most hospitals believed that installation of a robot was necessary as an option for treatment procedures, the future strategy of the hospital, and other reasons, the action of the hospital to gain prestige may be involved in the process of purchasing the equipment. In conclusion, robot-assisted laparoscopic radical prostatectomy has become popular as a surgical procedure for prostate cancer in our society. This may lead to a concentration of the surgical case load in a limited number of hospitals with robots. We also discuss the typical action of an acute-care hospital when it purchases expensive clinical medical equipment.

  11. Developing a successful robotics program.

    Science.gov (United States)

    Luthringer, Tyler; Aleksic, Ilija; Caire, Arthur; Albala, David M

    2012-01-01

    Advancements in the robotic surgical technology have revolutionized the standard of care for many surgical procedures. The purpose of this review is to evaluate the important considerations in developing a new robotics program at a given healthcare institution. Patients' interest in robotic-assisted surgery has and continues to grow because of improved outcomes and decreased periods of hospitalization. Resulting market forces have created a solid foundation for the implementation of robotic surgery into surgical practice. Given proper surgeon experience and an efficient system, robotic-assisted procedures have been cost comparable to open surgical alternatives. Surgeon training and experience is closely linked to the efficiency of a new robotics program. Formally trained robotic surgeons have better patient outcomes and shorter operative times. Training in robotics has shown no negative impact on patient outcomes or mentor learning curves. Individual economic factors of local healthcare settings must be evaluated when planning for a new robotics program. The high cost of the robotic surgical platform is best offset with a large surgical volume. A mature, experienced surgeon is integral to the success of a new robotics program.

  12. Effects of robot-assisted training on upper limb functional recovery during the rehabilitation of poststroke patients.

    Science.gov (United States)

    Daunoraviciene, Kristina; Adomaviciene, Ausra; Grigonyte, Agne; Griškevičius, Julius; Juocevicius, Alvydas

    2018-05-18

    The study aims to determine the effectiveness of robot-assisted training in the recovery of stroke-affected arms using an exoskeleton robot Armeo Spring. To identify the effect of robot training on functional recovery of the arm. A total of 34 stroke patients were divided into either an experimental group (EG; n= 17) or a control group (n= 17). EG was also trained to use the Armeo Spring during occupational therapy. Both groups were clinically assessed before and after treatment. Statistical comparison methods (i.e. one-tailed t-tests for differences between two independent means and the simplest test) were conducted to compare motor recovery using robot-assisted training or conventional therapy. Patients assigned to the EG showed a statistically significant improvement in upper extremity motor function when compared to the CG by FIM (Peffect in the EG and CG was meaningful for shoulder and elbow kinematic parameters. The findings show the benefits of robot therapy in two areas of functional recovery. Task-oriented robotic training in rehabilitation setting facilitates recovery not only of the motor function of the paretic arm but also of the cognitive abilities in stroke patients.

  13. How to successfully implement a robotic pediatric surgery program: lessons learned after 96 procedures.

    Science.gov (United States)

    de Lambert, Guénolée; Fourcade, Laurent; Centi, Joachim; Fredon, Fabien; Braik, Karim; Szwarc, Caroline; Longis, Bernard; Lardy, Hubert

    2013-06-01

    Both our teams were the first to implement pediatric robotic surgery in France. The aim of this study was to define the key points we brought to light so other pediatric teams that want to set up a robotic surgery program will benefit. We reviewed the medical records of all children who underwent robotic surgery between Nov 2007 and June 2011 in both departments, including patient data, installation and changes, operative time, hospital stay, intraoperative complications, and postoperative outcome. The department's internal organization, the organization within the hospital complex, and cost were evaluated. A total of 96 procedures were evaluated. There were 38 girls and 56 boys with average age at surgery of 7.6 years (range, 0.7-18 years) and average weight of 26 kg (range, 6-77 kg). Thirty-six patients had general surgery, 57 patients urologic surgery, and 1 thoracic surgery. Overall average operative time was 189 min (range, 70-550 min), and average hospital stay was 6.4 days (range, 2-24 days). The procedures of 3 patients were converted. Median follow-up was 18 months (range, 0.5-43 months). Robotic surgical procedure had an extra cost of 1934 compared to conventional open surgery. Our experience was similar to the findings described in the literature for feasibility, security, and patient outcomes; we had an overall operative success rate of 97 %. Three main actors are concerned in the implementation of a robotic pediatric surgery program: surgeons and anesthetists, nurses, and the administration. The surgeon is at the starting point with motivation for minimally invasive surgery without laparoscopic constraints. We found that it was possible to implement a long-lasting robotic surgery program with comparable quality of care.

  14. Robotic transverse colectomy for mid-transverse colon cancer: surgical techniques and oncologic outcomes.

    Science.gov (United States)

    Jung, Kyung Uk; Park, Yoonah; Lee, Kang Young; Sohn, Seung-Kook

    2015-06-01

    Robot-assisted surgery for colon cancer has been reported in many studies, most of which worked on right and/or sigmoid colectomy. The aim of this study was to report our experience of robotic transverse colectomy with an intracorporeal anastomosis, provide details of the surgical technique, and present the theoretical benefits of the procedure. This is a retrospective review of prospectively collected data of robotic surgery for colorectal cancer performed by a single surgeon between May 2007 and February 2011. Out of 162 consecutive cases, we identified three robotic transverse colectomies, using a hand-sewn intracorporeal anastomosis. Two males and one female underwent transverse colectomies for malignant or premalignant disease. The mean docking time, time spent using the robot, and total operative time were 5, 268, and 307 min, respectively. There were no conversions to open or conventional laparoscopic technique. The mean length of specimen and number of lymph nodes retrieved were 14.1 cm and 6.7, respectively. One patient suffered from a wound seroma and recovered with conservative management. The mean hospital stay was 8.7 days. After a median follow-up of 72 months, there were no local or systemic recurrences. Robotic transverse colectomy seems to be a safe and feasible technique. It may minimize the necessity of mobilizing both colonic flexures, with facilitated intracorporeal hand-sewn anastomosis. However, further prospective studies with a larger number of patients are required to draw firm conclusions.

  15. Comparison of fiber delivered CO2 laser and electrocautery in transoral robot assisted tongue base surgery.

    Science.gov (United States)

    Karaman, Murat; Gün, Taylan; Temelkuran, Burak; Aynacı, Engin; Kaya, Cem; Tekin, Ahmet Mahmut

    2017-05-01

    To compare intra-operative and post-operative effectiveness of fiber delivered CO 2 laser to monopolar electrocautery in robot assisted tongue base surgery. Prospective non-randomized clinical study. Twenty moderate to severe obstructive sleep apnea (OSA) patients, non-compliant with Continuous Positive Airway Pressure (CPAP), underwent Transoral Robotic Surgery (TORS) using the Da Vinci surgical robot in our University Hospital. OSA was treated with monopolar electrocautery in 10 patients, and with flexible CO 2 laser fiber in another 10 patients. The following parameters in the two sets are analyzed: Intraoperative bleeding that required cauterization, robot operating time, need for tracheotomy, postoperative self-limiting bleeding, length of hospitalization, duration until start of oral intake, pre-operative and post-operative minimum arterial oxygen saturation, pre-operative and post-operative Epworth Sleepiness Scale score, postoperative airway complication and postoperative pain. Mean follow-up was 12 months. None of the patients required tracheotomy and there were no intraoperative complications related to the use of the robot or the CO 2 laser. The use of CO 2 laser in TORS-assisted tongue base surgery resulted in less intraoperative bleeding that required cauterization, shorter robot operating time, shorter length of hospitalization, shorter duration until start of oral intake and less postoperative pain, when compared to electrocautery. Postoperative apnea-hypopnea index scores showed better efficacy of CO 2 laser than electrocautery. Comparison of postoperative airway complication rates and Epworth sleepiness scale scores were found to be statistically insignificant between the two groups. The use of CO 2 laser in robot assisted tongue base surgery has various intraoperative and post-operative advantages when compared to monopolar electrocautery.

  16. Robotic kidney transplantation with regional hypothermia: a step-by-step description of the Vattikuti Urology Institute-Medanta technique (IDEAL phase 2a).

    Science.gov (United States)

    Menon, Mani; Sood, Akshay; Bhandari, Mahendra; Kher, Vijay; Ghosh, Prasun; Abaza, Ronney; Jeong, Wooju; Ghani, Khurshid R; Kumar, Ramesh K; Modi, Pranjal; Ahlawat, Rajesh

    2014-05-01

    We recently reported on preclinical and feasibility studies (Innovation, Development, Exploration, Assessment, Long-term study [IDEAL] phase 0-1) of the development of robotic kidney transplantation (RKT) with regional hypothermia. This paper presents the IDEAL phase 2a studies of technique development. To describe the technique of RKT with regional hypothermia developed at two tertiary care institutions (Vattikuti Urology Institute and Medanta Hospital). We report on the safety profile and early graft function in these patients. This is a prospective study of 50 consecutive patients who underwent live-donor RKT at Medanta Hospital following a 3-yr planning/simulation phase at the Vattikuti Urology Institute. Demographic details, and perioperative and postoperative outcomes are reported for the initial 25 recipients who have completed a minimum 6-mo follow-up. Positioning and port placement were similar to that used for robotic radical prostatectomy. Allograft cooling was achieved by ice slush delivered through a GelPOINT device. The accompanying video details the operative technique. The primary outcome was posttransplant graft function. Secondary outcomes included technical success or failure and complication rates. Fifty patients underwent RKT successfully, 7 in the phase 1 and 43 in the phase 2 stages of the study. For the initial 25 patients, mean console, warm ischemia, arterial, and venous anastomotic times were 135, 2.4, 12, and 13.4 min, respectively. All grafts were cooled to 18-20 °C with no change in core body temperature. All grafts functioned immediately posttransplant and the mean serum creatinine level at discharge was 1.3mg/dl (range: 0.8-3.1mg/dl). No patient developed anastomotic leaks, wound complications, or wound infections. At 6-mo of follow-up, no patient had developed a lymphocele detected on CT scanning. Two patients underwent re-exploration, and one patient died of congestive heart failure (1.5 mo posttransplant). RKT with regional

  17. Robotic-assisted transperitoneal radical prostatectomy in a patient with pelvic kidney

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Alyami, Fahad A.

    2008-01-01

    Robots are increasingly utilized in urology, due to their favorable performance characteristics especially in prostatectomy and pyeloplasty. However, preoperative diagnosis of urogenital congenital anomalies and preoperative planning are important aspects to be considered. The presence of ectopic pelvic kidney is a challenge for the surgeon to perform robotic-assisted radical prostatectomy (RARP) without injury to the pelvic kidney (PC) or its blood supply. We report our experience of performing RARP in a patient with a PK. (author)

  18. Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Kim, Dae Ho; Son, Sang Jun; Mun, Jun Ki; Seo, Seok Jin; Lee, Je Hee

    2016-01-01

    By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change

  19. E2Rebot: A robotic platform for upper limb rehabilitation in patients with neuromotor disability

    Directory of Open Access Journals (Sweden)

    Juan C Fraile

    2016-08-01

    Full Text Available The use of robotic platforms for neuro-rehabilitation may boost the neural plasticity process and improve motor recovery in patients with upper limb mobility impairment as a consequence of an acquired brain injury. A robotic platform for this aim must provide ergonomic and friendly design, human safety, intensive task-oriented therapy, and assistive forces. Its implementation is a complex process that involves new developments in the mechanical, electronics, and control fields. This article presents the end-effector rehabilitation robot, a 2-degree-of-freedom planar robotic platform for upper limb rehabilitation in patients with neuromotor disability after a stroke. We describe the ergonomic mechanical design, the system control architecture, and the rehabilitation therapies that can be performed. The impedance-based haptic controller implemented in end-effector rehabilitation robot uses the information provided by a JR3 force sensor to achieve an efficient and friendly patient–robot interaction. Two task-oriented therapy modes have been implemented based on the “assist as needed” paradigm. As a result, the amount of support provided by the robot adapts to the patient’s requirements, maintaining the therapy as intensive as possible without compromising the patient’s health and safety and promoting engagement.

  20. Effect of human-robot interaction on muscular synergies on healthy people and post-stroke chronic patients.

    Science.gov (United States)

    Scano, A; Chiavenna, A; Caimmi, M; Malosio, M; Tosatti, L M; Molteni, F

    2017-07-01

    Robot-assisted training is a widely used technique to promote motor re-learning on post-stroke patients that suffer from motor impairment. While it is commonly accepted that robot-based therapies are potentially helpful, strong insights about their efficacy are still lacking. The motor re-learning process may act on muscular synergies, which are groups of co-activating muscles that, being controlled as a synergic group, allow simplifying the problem of motor control. In fact, by coordinating a reduced amount of neural signals, complex motor patterns can be elicited. This paper aims at analyzing the effects of robot assistance during 3D-reaching movements in the framework of muscular synergies. 5 healthy people and 3 neurological patients performed free and robot-assisted reaching movements at 2 different speeds (slow and quasi-physiological). EMG recordings were used to extract muscular synergies. Results indicate that the interaction with the robot very slightly alters healthy people patterns but, on the contrary, it may promote the emergency of physiological-like synergies on neurological patients.

  1. Predicting efficacy of robot-aided rehabilitation in chronic stroke patients using an MRI-compatible robotic device.

    Science.gov (United States)

    Sergi, Fabrizio; Krebs, Hermano Igo; Groissier, Benjamin; Rykman, Avrielle; Guglielmelli, Eugenio; Volpe, Bruce T; Schaechter, Judith D

    2011-01-01

    We are investigating the neural correlates of motor recovery promoted by robot-mediated therapy in chronic stroke. This pilot study asked whether efficacy of robot-aided motor rehabilitation in chronic stroke could be predicted by a change in functional connectivity within the sensorimotor network in response to a bout of motor rehabilitation. To address this question, two stroke patients participated in a functional connectivity MRI study pre and post a 12-week robot-aided motor rehabilitation program. Functional connectivity was evaluated during three consecutive scans before the rehabilitation program: resting-state; point-to-point reaching movements executed by the paretic upper extremity (UE) using a newly developed MRI-compatible sensorized passive manipulandum; resting-state. A single resting-state scan was conducted after the rehabilitation program. Before the program, UE movement reduced functional connectivity between the ipsilesional and contralesional primary motor cortex. Reduced interhemispheric functional connectivity persisted during the second resting-state scan relative to the first and during the resting-state scan after the rehabilitation program. Greater reduction in interhemispheric functional connectivity during the resting-state was associated with greater gains in UE motor function induced by the 12-week robotic therapy program. These findings suggest that greater reduction in interhemispheric functional connectivity in response to a bout of motor rehabilitation may predict greater efficacy of the full rehabilitation program.

  2. Robotic longitudinal pancreaticojejunostomy for chronic pancreatitis: Comparison of clinical outcomes and cost to the open approach.

    Science.gov (United States)

    Kirks, Russell C; Lorimer, Patrick D; Fruscione, Michael; Cochran, Allyson; Baker, Erin H; Iannitti, David A; Vrochides, Dionisios; Martinie, John B

    2017-09-01

    This study compares clinical and cost outcomes of robot-assisted laparoscopic (RAL) and open longitudinal pancreaticojejunostomy (LPJ) for chronic pancreatitis. Clinical and cost data were retrospectively compared between open and RAL LPJ performed at a single center from 2008-2015. Twenty-six patients underwent LPJ: 19 open and 7 RAL. Two robot-assisted cases converted to open were included in the open group for analysis. Patients undergoing RAL LPJ had less intraoperative blood loss, a shorter surgical length of stay, and lower medication costs. Operation supply cost was higher in the RAL group. No difference in hospitalization cost was found. Versus the open approach, RAL LPJ performed for chronic pancreatitis shortens hospitalization and reduces medication costs; hospitalization costs are equivalent. A higher operative cost for RAL LPJ is mitigated by a shorter hospitalization. Decreased morbidity and healthcare resource economy support use of the robotic approach for LPJ when appropriate. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Hand-assisted hybrid laparoscopic-robotic total proctocolectomy with ileal pouch--anal anastomosis.

    Science.gov (United States)

    Morelli, Luca; Guadagni, Simone; Mariniello, Maria Donatella; Furbetta, Niccolò; Pisano, Roberta; D'Isidoro, Cristiano; Caprili, Giovanni; Marciano, Emanuele; Di Candio, Giulio; Boggi, Ugo; Mosca, Franco

    2015-08-01

    Few studies have reported minimally invasive total proctocolectomy with ileal pouch-anal anastomosis (IPAA) for ulcerative colitis (UC) and familial adenomatous polyposis (FAP). We herein report a novel hand-assisted hybrid laparoscopic-robotic technique for patients with FAP and UC. Between February 2010 and March 2014, six patients underwent hand-assisted hybrid laparoscopic-robotic total proctocolectomy with IPAA. The abdominal colectomy was performed laparoscopically with hand assistance through a transverse suprapubic incision, also used to fashion the ileal pouch. The proctectomy was carried out with the da Vinci Surgical System. The IPAA was hand-sewn through a trans-anal approach. The procedure was complemented by a temporary diverting loop ileostomy. The mean hand-assisted laparoscopic surgery (HALS) time was 154.6 (±12.8) min whereas the mean robotic time was 93.6 (±8.1) min. In all cases, a nerve-sparing proctectomy was performed, and no conversion to traditional laparotomy was required. The mean postoperative hospital stay was 13.2 (±7.4) days. No anastomotic leakage was observed. To date, no autonomic neurological disorders have been observed with a mean of 5.8 (±1.3) bowel movements per day. The hand-assisted hybrid laparoscopic-robotic approach to total proctocolectomy with IPAA has not been previously described. Our report shows the feasibility of this hybrid approach, which surpasses most of the limitations of pure laparoscopic and robotic techniques. Further experience is necessary to refine the technique and fully assess its potential advantages.

  4. Operative technique and early experience for robotic-assisted laparoscopic nephroureterectomy (RALNU) using da Vinci Xi.

    Science.gov (United States)

    Darwiche, Fadi; Swain, Sanjaya; Kallingal, George; Punnen, Sanoj; Manoharan, Murugesan; Parekh, Dipen J; Gonzalgo, Mark L

    2015-01-01

    Robotic-assisted laparoscopic nephroureterectomy (RALNU) has been previously utilized for management of upper tract urothelial carcinoma. The da Vinci Xi surgical system was released in April of 2014. We describe our operative technique and early experience for RALNU using the da Vinci Xi system highlighting unique features of this surgical platform. A total of 10 patients with a diagnosis of upper tract urothelial carcinoma underwent RALNU using the da Vinci Xi system between April and November of 2014. A novel, oblique "in line" robotic trocar configuration was utilized to access the upper abdomen (nephrectomy portion) and pelvis (bladder cuff excision) without undocking. The port hopping feature of da Vinci Xi was utilized to facilitate optimal, multi-quadrant visualization during RALNU. Robotic-assisted laparoscopic nephroureterectomy was successfully completed without open conversion in all 10 patients. Mean operative time was 184 min (range 140-300 min), mean estimated blood loss was 121 cc (range 60-300 cc), and mean hospital stay was 2.4 days. Final pathology demonstrated high grade urothelial carcinoma in all patients. Surgical margins were negative in all patients. No intra-operative complications were encountered. One patient developed a pulmonary embolus after being discharged. No patients required a blood transfusion. Mean patient follow-up was 130 days (range 15-210 days). The use of da Vinci Xi with a novel, oblique "in line" port configuration and camera port hopping technique allows for an efficient and reproducible method for RALNU without the need for repositioning the patient or the robot during surgery.

  5. Usability assessment of ASIBOT: a portable robot to aid patients with spinal cord injury

    OpenAIRE

    Jardón Huete, Alberto; Gil, Ángel M.; Peña, Ana I. de la; Monje Micharet, Concepción Alicia; Balaguer Bernaldo de Quirós, Carlos

    2011-01-01

    The usability concept refers to aspects related to the use of products that are closely linked to the user's degree of satisfaction. Our goal is to present a functional evaluation methodology for assessing the usability of sophisticated technical aids, such as a portable robot for helping disabled patients with severe spinal cord injuries. The specific manipulator used for this task is ASIBOT, a personal assistance robot totally developed by RoboticsLab at the University Carlos III of Madrid....

  6. [Robot-aided training in rehabilitation].

    Science.gov (United States)

    Hachisuka, Kenji

    2010-02-01

    Recently, new training techniques that involve the use of robots have been used in the rehabilitation of patients with hemiplegia and paraplegia. Robots used for training the arm include the MIT-MANUS, Arm Trainer, mirror-image motion enabler (MIME) robot, and the assisted rehabilitation and measurement (ARM) Guide. Robots that are used for lower-limb training are the Rehabot, Gait Trainer, Lokomat, LOPES Exoskeleton Robot, and Gait Assist Robot. Robot-aided therapy has enabled the functional training of the arm and the lower limbs in an effective, easy, and comfortable manner. Therefore, with this type of therapy, the patients can repeatedly undergo sufficient and accurate training for a prolonged period. However, evidence of the benefits of robot-aided training has not yet been established.

  7. Propensity Score-Matched Analysis of Clinical and Financial Outcomes After Robotic and Laparoscopic Colorectal Resection.

    Science.gov (United States)

    Al-Mazrou, Ahmed M; Baser, Onur; Kiran, Ravi P

    2018-06-01

    The study aims to evaluate the clinical and financial outcomes of the use of robotic when compared to laparoscopic colorectal surgery and any changes in these over time. From the Premier Perspective database, patients who underwent elective laparoscopic and robotic colorectal resections from 2012 to 2014 were included. Laparoscopic colorectal resections were propensity score matched to robotic cases for patient, disease, procedure, surgeon specialty, and hospital type and volume. The two groups were compared for conversion, hospital stay, 30-day post-discharge readmission, mortality, and complications. Direct, cumulative, and total (including 30-day post-discharge) costs were evaluated. Clinical and financial outcomes were also separately assessed for each of the included years. Of 36,701 patients, 32,783 (89.3%) had laparoscopic colorectal resection and 3918 (10.7%) had robotic colorectal resection; 4438 procedures (2219 in each group) were propensity score matched. For the entire period, conversion to open approach (4.7 vs. 3.7%, p = 0.1) and hospital stay (mean days [SD] 6 [5.3] vs. 5 [4.6], p = 0.2) were comparable between robotic and laparoscopic procedures. Surgical and medical complications were also the same for the two groups. However, the robotic approach was associated with lower readmission (6.3 vs. 4.8%, p = 0.04). Wound or abdominal infection (4.7 vs. 2.3%, p = 0.01) and respiratory complications (7.4 vs. 4.7%, p = 0.02) were significantly lower for the robotic group in the final year of inclusion, 2014. Direct, cumulative, and total (including 30-day post-discharge) costs were significantly higher for robotic surgery. The difference in costs between the two approaches reduced over time (direct cost difference: 2012, $2698 vs. 2013, $2235 vs. 2014, $1402). Robotic colorectal surgery can be performed with comparable clinical outcomes to laparoscopy. With greater use of the technology, some further recovery benefits may be evident

  8. Patient-specific surgical simulator for the pre-operative planning of single-incision laparoscopic surgery with bimanual robots.

    Science.gov (United States)

    Turini, Giuseppe; Moglia, Andrea; Ferrari, Vincenzo; Ferrari, Mauro; Mosca, Franco

    2012-01-01

    The trend of surgical robotics is to follow the evolution of laparoscopy, which is now moving towards single-incision laparoscopic surgery. The main drawback of this approach is the limited maneuverability of the surgical tools. Promising solutions to improve the surgeon's dexterity are based on bimanual robots. However, since both robot arms are completely inserted into the patient's body, issues related to possible unwanted collisions with structures adjacent to the target organ may arise. This paper presents a simulator based on patient-specific data for the positioning and workspace evaluation of bimanual surgical robots in the pre-operative planning of single-incision laparoscopic surgery. The simulator, designed for the pre-operative planning of robotic laparoscopic interventions, was tested by five expert surgeons who evaluated its main functionalities and provided an overall rating for the system. The proposed system demonstrated good performance and usability, and was designed to integrate both present and future bimanual surgical robots.

  9. Multiquadrant robotic colorectal surgery: the da Vinci Xi vs Si comparison.

    Science.gov (United States)

    Protyniak, Bogdan; Jorden, Jeffrey; Farmer, Russell

    2018-03-01

    The newly introduced da Vinci Xi Surgical System hopes to address the shortcomings of its predecessor, specifically robotic arm restrictions and difficulty working in multiple quadrants. We compare the two robot platforms in multiquadrant surgery at a major colorectal referral center. Forty-four patients in the da Vinci Si group and 26 patients in the Xi group underwent sigmoidectomy or low anterior resection between 2014 and 2016. Patient demographics, operative variables, and postoperative outcomes were compared using descriptive statistics. Both groups were similar in age, sex, BMI, pelvic surgeries, and ASA class. Splenic flexure was mobilized in more (p = 0.045) da Vinci Xi cases compared to da Vinci Si both for sigmoidectomy (50 vs 15.4%) and low anterior resection (60 vs 29%). There was no significant difference in operative time (219.9 vs 224.7 min; p = 0.640), blood loss (170.0 vs 188.1 mL; p = 0.289), length of stay (5.7 vs 6 days; p = 0.851), or overall complications (26.9 vs 22.7%; p = 0.692) between the da Vinci Xi and Si groups, respectively. Single-dock multiquadrant robotic surgery, measured by splenic flexure mobilization with concomitant pelvic dissection, was more frequently performed using the da Vinci Xi platform with no increase in operative time, bleeding, or postoperative complications. The new platform provides surgeons an easier alternative to the da Vinci Si dual docking or combined robotic/laparoscopic multiquadrant surgery.

  10. How does the robot affect outcomes? A retrospective review of open, laparoscopic, and robotic Heller myotomy for achalasia.

    Science.gov (United States)

    Shaligram, Abhijit; Unnirevi, Jayaraj; Simorov, Anton; Kothari, Vishal M; Oleynikov, Dmitry

    2012-04-01

    Robotic techniques are routinely used in urological and gynecological procedures; however, their role in general surgical procedures is limited. A robotic technique has been successfully adopted for a minimally invasive Heller myotomy procedure for achalasia. This study aims to compare perioperative outcomes following open, laparoscopic, and robotic Heller myotomy. This study is a multicenter, retrospective analysis utilizing a large administrative database. The University Health System Consortium (UHC) is an alliance between academic medical centers and affiliate hospitals. The UHC database was accessed using International Classification of Diseases, Ninth Revision, Clinical Modification codes and analyzed. 2,683 patients with achalasia underwent Heller myotomy between October 2007 and June 2011. Myotomy was performed by open surgery (OM) in 418 patients, by laparoscopic approach (LM) in 2,116, and by robotic approach (RM) in 149. Comparison between LM and RM groups demonstrated no significant difference in mortality (0.14 vs. 0.0%; P = 1), morbidity (5.19 vs. 4.02%; P = 0.7), intensive care unit (ICU) admission (6.62 vs. 3.36%; P = 0.12), length of stay (LOS) (2.70 ± 3.87 days vs. 2.42 ± 2.69 days; P = 0.34), or 30-day readmission (1.41 vs. 2.84%; P = 0.27). However, hospital costs were significantly lower for the LM group (US $7,441 ± 7,897 vs. US $9,415 ± 5,515; P = 0.0028). Comparison between OM and RM demonstrated significant lower morbidity (9.08 vs. 4.02%; P = 0.02), ICU admission rate (14.01 vs. 3.36%, P = 0.0002), and LOS (4.42 ± 5.25 days vs. 2.42 ± 2.69 days; P = 0.0001). The perioperative outcomes are superior in LM and RM groups when compared with OM. The outcomes for the LM and RM group are comparable, with the robotic group having slightly improved results, although with increased costs. We conclude that robotic surgery is equivalent in safety and efficacy to laparoscopic Heller myotomy, and feel that the increased cost should come down as

  11. Robot-aided therapy for upper limbs in patients with stroke-related lesions. Brief report of a clinical experience

    Science.gov (United States)

    2011-01-01

    This study was aimed at verifying the improvement on the motor impairment and functionality in 19 patients with chronic hemiparesis after stroke treated with a robot-aided rehabilitation protocol using the ReoGo™ system (Motorika Medical Ltd, Israel), and at evaluating the persistence of the effects after 1 month. The study also focused on the actual possibility of administering the robot-aided therapy with the ReoGo™ for the upper limbs and on the patients' degree of acceptance and compliance with the treatment. Subjects underwent an assessment prior to the start of the rehabilitation project (T-1), one at the start (T0), one at the end of the treatment (T1) and one after one month from the end of the treatment (T2). The following tests were administered: (i) Fugl-Meyer (FM) upper limb; Ashworth scale (AS); Functional Independence Measure (FIM™) (T-1 - T2); (ii) strength evaluation; Visual Analogue Scale (VAS) for pain; Frenchay Arm test (FAT); Box and Block test (BBT); Timed Up and Go (TUG) test (T0 - T2). Additionally, the Euro-QoL questionnaire and a VAS for the treatment satisfaction were administered to the subjects. Non-statistical difference of scores at T-1 and T0 on almost the entire battery of tasks suggested a stable patients' performance prior to the start of the rehabilitation. With the exception of the Medical Research Council (MRC) and the AS sub-scales measuring -as appropriate- strength and spasticity of the shoulder, triceps and wrist, all scores showed a significant increase between T0 and T1. The improvement on the pain could not be proved significant (p = 0.10). A significant increase between T0 and T2 was found for all assessment scores, with the exception of the MRC for external shoulder rotators (p = 0.05) and of the AS for shoulder (p = 0.32) and wrist (p = 0.08). Substantial stability was observed between T1 and T2. Patients were capable of completing the treatment and showed good participant satisfaction. This pilot study led to

  12. Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Son, Sang Jun; Mun, Jun Ki; Seo, Seok Jin; Lee, Je Hee [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2016-06-15

    By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change.

  13. Tumor deposit is a poor prognostic indicator in patients who underwent simultaneous resection for synchronous colorectal liver metastases

    Directory of Open Access Journals (Sweden)

    Lin Q

    2015-01-01

    Full Text Available Qi Lin,# Ye Wei,# Li Ren,# Yunshi Zhong,# Chunzhi Qin, Peng Zheng, Pingping Xu, Dexiang Zhu, Meiling Ji, Jianmin XuDepartment of General Surgery, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China#These authors contributed equally to this workBackground: Tumor deposits are one of the important influencing factors among the different editions of Tumor, Node, Metastasis classification. Incidence and prognosis of tumor deposits in stage I, II, and III colorectal cancer patients has been explored. The aim of this study was to determine the prognostic value of tumor deposits in stage IV colorectal cancer patients who underwent simultaneous resection for synchronous colorectal liver metastases (SCRLM.Methods: Clinicopathological and outcome data of 146 consecutive SCRLM patients who underwent simultaneous R0 resection between July 2003 and July 2013 were collected from our prospectively established SCRLM database. The prognostic value of tumor deposits was evaluated by Kaplan–Meier and Cox regression analysis.Results: Tumor deposits were detected in 41.8% (61/146 of these SCRLM patients. Tumor deposits were significantly correlated with lymph node metastasis and nerve invasion of the primary tumors (P=0.002, P=0.041; respectively. The Kaplan–Meier survival analysis revealed that the overall survival (OS and disease-free survival (DFS of SCRLM patients with tumor deposits were significantly poorer than those with no tumor deposits (P=0.039, P=0.001; respectively. And with multivariate analysis, we found that positive tumor deposits were significantly associated with shorter DFS independent of lymph node status (P=0.002. Subgroup analysis found that of the 57 SCRLM patients with negative lymph node status, the OS and DFS of patients with positive tumor deposits were significantly shorter than those with negative tumor deposits (P=0.002 and P=0.031, respectively. Of the 89 patients with positive lymph node status, the OS of

  14. Evolution of robotic nephrectomy for living donation: from hand-assisted to totally robotic technique.

    Science.gov (United States)

    Giacomoni, Alessandro; Di Sandro, Stefano; Lauterio, Andrea; Concone, Giacomo; Mangoni, Iacopo; Mihaylov, Plamen; Tripepi, Matteo; De Carlis, Luciano

    2014-09-01

    The application of robotic-assisted surgery offers EndoWrist instruments and 3-D visualization of the operative field, which are improvements over traditional laparoscopy. The results of the few studies published so far have shown that living donor nephrectomy using the robot-assisted technique is safe, feasible, and offers advantages to patients. Since November 2009, 16 patients have undergone robotic-assisted living donor nephrectomy at our Institute. Patients were divided into two groups according to the surgical technique adopted for the procedure: Group A, hand-assisted robotic nephrectomy (eight patients); Group B, totally robotic nephrectomy (eight patients). Intra-operative bleeding was similar in the two groups (90 vs 100 mL for Group A and B, respectively). Median warm ischemia time was significantly shorter in Group A (2.3 vs 5.1 min for Group A and B, respectively, P-value = 0.05). Switching to the open procedure was never required. Median operative time was not significantly longer in Group A than Group B (275 min vs 250 min, respectively). Robotic assisted living kidney recovery is a safe and effective procedure. Considering the overall technical, clinical, and feasibility aspects of living kidney donation, we believe that the robotic assisted technique is the method of choice for surgeon's comfort and donors' safety. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Robot-assisted practice of gait and stair climbing in nonambulatory stroke patients.

    Science.gov (United States)

    Hesse, Stefan; Tomelleri, Christopher; Bardeleben, Anita; Werner, Cordula; Waldner, Andreas

    2012-01-01

    A novel gait robot enabled nonambulatory patients the repetitive practice of gait and stair climbing. Thirty nonambulatory patients with subacute stroke were allocated to two groups. During 60 min sessions every workday for 4 weeks, the experimental group received 30 min of robot training and 30 min of physiotherapy and the control group received 60 min of physiotherapy. The primary variable was gait and stair climbing ability (Functional Ambulation Categories [FAC] score 0-5); secondary variables were gait velocity, Rivermead Mobility Index (RMI), and leg strength and tone blindly assessed at onset, intervention end, and follow-up. Both groups were comparable at onset and functionally improved over time. The improvements were significantly larger in the experimental group with respect to the FAC, RMI, velocity, and leg strength during the intervention. The FAC gains (mean +/- standard deviation) were 2.4 +/- 1.2 (experimental group) and 1.2 +/- 1.5 (control group), p = 0.01. At the end of the intervention, seven experimental group patients and one control group patient had reached an FAC score of 5, indicating an ability to climb up and down one flight of stairs. At follow-up, this superior gait ability persisted. In conclusion, the therapy on the novel gait robot resulted in a superior gait and stair climbing ability in nonambulatory patients with subacute stroke; a higher training intensity was the most likely explanation. A large randomized controlled trial should follow.

  16. Individual finger synchronized robot-assisted hand rehabilitation in subacute to chronic stroke: a prospective randomized clinical trial of efficacy.

    Science.gov (United States)

    Hwang, Chang Ho; Seong, Jin Wan; Son, Dae-Sik

    2012-08-01

    To evaluate individual finger synchronized robot-assisted hand rehabilitation in stroke patients. Prospective parallel group randomized controlled clinical trial. The study recruited patients who were ≥18 years old, more than three months post stroke, showed limited index finger movement and had weakened and impaired hand function. Patients with severe sensory loss, spasticity, apraxia, aphasia, disabling hand disease, impaired consciousness or depression were excluded. Patients received either four weeks (20 sessions) of active robot-assisted intervention (the FTI (full-term intervention) group, 9 patients) or two weeks (10 sessions) of early passive therapy followed by two weeks (10 sessions) of active robot-assisted intervention (the HTI (half-term intervention) group, 8 patients). Patients underwent arm function assessments prior to therapy (baseline), and at 2, 4 and 8 weeks after starting therapy. Compared to baseline, both the FTI and HTI groups showed improved results for the Jebsen Taylor test, the wrist and hand subportion of the Fugl-Meyer arm motor scale, active movement of the 2nd metacarpophalangeal joint, grasping, and pinching power (P vs. 46.4 ± 37.4) and wrist and hand subportion of the Fugl-Meyer arm motor scale (4.3 ± 1.9 vs. 3.4 ± 2.5) after eight weeks. A four-week rehabilitation using a novel robot that provides individual finger synchronization resulted in a dose-dependent improvement in hand function in subacute to chronic stroke patients.

  17. Biofeedback for robotic gait rehabilitation

    Directory of Open Access Journals (Sweden)

    Colombo Gery

    2007-01-01

    Full Text Available Abstract Background Development and increasing acceptance of rehabilitation robots as well as advances in technology allow new forms of therapy for patients with neurological disorders. Robot-assisted gait therapy can increase the training duration and the intensity for the patients while reducing the physical strain for the therapist. Optimal training effects during gait therapy generally depend on appropriate feedback about performance. Compared to manual treadmill therapy, there is a loss of physical interaction between therapist and patient with robotic gait retraining. Thus, it is difficult for the therapist to assess the necessary feedback and instructions. The aim of this study was to define a biofeedback system for a gait training robot and test its usability in subjects without neurological disorders. Methods To provide an overview of biofeedback and motivation methods applied in gait rehabilitation, previous publications and results from our own research are reviewed. A biofeedback method is presented showing how a rehabilitation robot can assess the patients' performance and deliver augmented feedback. For validation, three subjects without neurological disorders walked in a rehabilitation robot for treadmill training. Several training parameters, such as body weight support and treadmill speed, were varied to assess the robustness of the biofeedback calculation to confounding factors. Results The biofeedback values correlated well with the different activity levels of the subjects. Changes in body weight support and treadmill velocity had a minor effect on the biofeedback values. The synchronization of the robot and the treadmill affected the biofeedback values describing the stance phase. Conclusion Robot-aided assessment and feedback can extend and improve robot-aided training devices. The presented method estimates the patients' gait performance with the use of the robot's existing sensors, and displays the resulting biofeedback

  18. Robotics in percutaneous cardiovascular interventions.

    Science.gov (United States)

    Pourdjabbar, Ali; Ang, Lawrence; Behnamfar, Omid; Patel, Mitul P; Reeves, Ryan R; Campbell, Paul T; Madder, Ryan D; Mahmud, Ehtisham

    2017-11-01

    The fundamental technique of performing percutaneous cardiovascular (CV) interventions has remained unchanged and requires operators to wear heavy lead aprons to minimize exposure to ionizing radiation. Robotic technology is now being utilized in interventional cardiology partially as a direct result of the increasing appreciation of the long-term occupational hazards of the field. This review was undertaken to report the clinical outcomes of percutaneous robotic coronary and peripheral vascular interventions. Areas covered: A systematic literature review of percutaneous robotic CV interventions was undertaken. The safety and feasibility of percutaneous robotically-assisted CV interventions has been validated in simple to complex coronary disease, and iliofemoral disease. Studies have shown that robotically-assisted PCI significantly reduces operator exposure to harmful ionizing radiation without compromising procedural success or clinical efficacy. In addition to the operator benefits, robotically-assisted intervention has the potential for patient advantages by allowing more accurate lesion length measurement, precise stent placement and lower patient radiation exposure. However, further investigation is required to fully elucidate these potential benefits. Expert commentary: Incremental improvement in robotic technology and telecommunications would enable treatment of an even broader patient population, and potentially provide remote robotic PCI.

  19. Robot-assisted radical cystectomy with intracorporeal neobladder diversion: The Karolinska experience.

    Science.gov (United States)

    Collins, Justin W; Sooriakumaran, P; Sanchez-Salas, R; Ahonen, R; Nyberg, T; Wiklund, N P; Hosseini, A

    2014-07-01

    The aim of this report is to describe our surgical technique of totally intracorporeal robotic assisted radical cystectomy (RARC) with neobladder formation. Between December 2003 and March 2013, a total of 147 patients (118 male, 29 female) underwent totally intracorporeal RARC for urinary bladder cancer. We also performed a systematic search of Medline, Embase and PubMed databases using the terms RARC, robotic cystectomy, robot-assisted, totally intracorporeal RARC, intracorporeal neobladder, intracorporeal urinary diversion, oncological outcomes, functional outcomes, and complication rates. The mean age of our patients was 64 years (range 37-87). On surgical pathology 47% had pT1 or less disease, 27% had pT2, 16% had pT3 and 10% had pT4. The mean number of lymph nodes removed was 21 (range 0-60). 24% of patients had lymph node positive dAQ1isease. Positive surgical margins occurred in 6 cases (4%). Mean follow-up was 31 months (range 4-115 months). Two patients (1.4%) died within 90 days of their operation. Using Kaplan-Meier analysis, overall survival and cancer specific survival at 60 months was 68% and 69.6%, respectively. 80 patients (54%) received a continent diversion with totally intracorporeal neobladder formation. In the neobladder subgroup median total operating time was 420 minutes (range 265-760). Daytime continence and satisfactory sexual function or potency at 12 months ranged between 70-90% in both men and women. Our experience with totally intracorporeal RARC demonstrates acceptable oncological and functional outcomes that suggest this is a viable alternative to open radical cystectomy.

  20. Robotic aortic surgery.

    Science.gov (United States)

    Duran, Cassidy; Kashef, Elika; El-Sayed, Hosam F; Bismuth, Jean

    2011-01-01

    Surgical robotics was first utilized to facilitate neurosurgical biopsies in 1985, and it has since found application in orthopedics, urology, gynecology, and cardiothoracic, general, and vascular surgery. Surgical assistance systems provide intelligent, versatile tools that augment the physician's ability to treat patients by eliminating hand tremor and enabling dexterous operation inside the patient's body. Surgical robotics systems have enabled surgeons to treat otherwise untreatable conditions while also reducing morbidity and error rates, shortening operative times, reducing radiation exposure, and improving overall workflow. These capabilities have begun to be realized in two important realms of aortic vascular surgery, namely, flexible robotics for exclusion of complex aortic aneurysms using branched endografts, and robot-assisted laparoscopic aortic surgery for occlusive and aneurysmal disease.

  1. Differences in self-reported outcomes of open prostatectomy patients and robotic prostatectomy patients in an international web-based survey.

    Science.gov (United States)

    O'Shaughnessy, Peter Kevin; Laws, Thomas A; Pinnock, Carol; Moul, Judd W; Esterman, Adrian

    2013-12-01

    To compare patient reported outcomes between robotic assisted surgery and non-robotic assisted surgery. This was an international web-based survey based on a qualitative research and literature review, an internet-based questionnaire was developed with approximately 70 items. The questionnaire included both closed and open-ended questions. Responses were received from 193 men of whom 86 had received either open (OP) or robotic (RALP) surgery. A statistically significant (p=0.027), ranked analysis of covariance was found demonstrating higher recent distress in the robotic (RALP) surgery group. Although not statistically significant, there was a pattern of men having robotic (RALP) surgery reporting fewer urinary and bowel problems, but having a greater rate of sexual dysfunction. Men who opt for robotic surgery may have higher expectations for robotic (RALP) surgery, when these expectations are not fully met they may be less likely to accept the consequences of this major cancer surgery. Information regarding surgical choice needs to be tailored to ensure that men diagnosed with prostate cancer are fully informed of not only short term surgical and physical outcomes such as erectile dysfunction and incontinence, but also of potential issues with regards to masculinity, lifestyle and sexual health. Copyright © 2013. Published by Elsevier Ltd.

  2. Combined effects of cerebellar transcranial direct current stimulation and transcutaneous spinal direct current stimulation on robot-assisted gait training in patients with chronic brain stroke: A pilot, single blind, randomized controlled trial.

    Science.gov (United States)

    Picelli, Alessandro; Chemello, Elena; Castellazzi, Paola; Filippetti, Mirko; Brugnera, Annalisa; Gandolfi, Marialuisa; Waldner, Andreas; Saltuari, Leopold; Smania, Nicola

    2018-01-01

    Preliminary evidence showed additional effects of anodal transcranial direct current stimulation over the damaged cerebral hemisphere combined with cathodal transcutaneous spinal direct current stimulation during robot-assisted gait training in chronic stroke patients. This is consistent with the neural organization of locomotion involving cortical and spinal control. The cerebellum is crucial for locomotor control, in particular for avoidance of obstacles, and adaptation to novel conditions during walking. Despite its key role in gait control, to date the effects of transcranial direct current stimulation of the cerebellum have not been investigated on brain stroke patients treated with robot-assisted gait training. To evaluate the effects of cerebellar transcranial direct current stimulation combined with transcutaneous spinal direct current stimulation on robot-assisted gait training in patients with chronic brain stroke. After balanced randomization, 20 chronic stroke patients received ten, 20-minute robot-assisted gait training sessions (five days a week, for two consecutive weeks) combined with central nervous system stimulation. Group 1 underwent on-line cathodal transcranial direct current stimulation over the contralesional cerebellar hemisphere + cathodal transcutaneous spinal direct current stimulation. Group 2 received on-line anodal transcranial direct current stimulation over the damaged cerebral hemisphere + cathodal transcutaneous spinal direct current stimulation. The primary outcome was the 6-minute walk test performed before, after, and at follow-up at 2 and 4 weeks post-treatment. The significant differences in the 6-minute walk test noted between groups at the first post-treatment evaluation (p = 0.041) were not maintained at either the 2-week (P = 0.650) or the 4-week (P = 0.545) follow-up evaluations. Our preliminary findings support the hypothesis that cathodal transcranial direct current stimulation over the contralesional

  3. Epidural Hematoma and Abscess Related to Thoracic Epidural Analgesia: A Single-Center Study of 2,907 Patients Who Underwent Lung Surgery.

    Science.gov (United States)

    Kupersztych-Hagege, Elisa; Dubuisson, Etienne; Szekely, Barbara; Michel-Cherqui, Mireille; François Dreyfus, Jean; Fischler, Marc; Le Guen, Morgan

    2017-04-01

    To report the major complications (epidural hematoma and abscess) of postoperative thoracic epidural analgesia in patients who underwent lung surgery. Prospective, monocentric study. A university hospital. All lung surgical patients who received postoperative thoracic epidural analgesia between November 2007 and November 2015. Thoracic epidural analgesia for patients who underwent lung surgery. During the study period, data for 2,907 patients were recorded. The following 3 major complications were encountered: 1 case of epidural hematoma (0.34 case/1,000; 95% confidence interval 0.061-1.946), for which surgery was performed, and 2 cases of epidural abscesses (0.68 case/1,000; 95% confidence interval 0.189-2.505), which were treated medically. The risk range of serious complications was moderate; only the patient who experienced an epidural hematoma also experienced permanent sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Modular robotics for playful physiotherapy

    DEFF Research Database (Denmark)

    Lund, Henrik Hautop

    2009-01-01

    We developed modular robotic tiles to be used for playful physiotherapy, which is supposed to motivate patients to engage in and perform physical rehabilitation exercises. We tested the modular robotic tiles for an extensive period of time (3 years) in daily use in a hospital rehabilitation unit e.......g. for cardiac patients. Also, the tiles were tested for performing physical rehabilitation of stroke patients in their private home. In all pilot test cases qualitative feedback indicate that the patients find the playful use of modular robotic tiles engaging and motivating for them to perform...

  5. Robot training for hand motor recovery in subacute stroke patients: A randomized controlled trial.

    Science.gov (United States)

    Orihuela-Espina, Felipe; Roldán, Giovana Femat; Sánchez-Villavicencio, Israel; Palafox, Lorena; Leder, Ronald; Sucar, Luis Enrique; Hernández-Franco, Jorge

    2016-01-01

    Evidence of superiority of robot training for the hand over classical therapies in stroke patients remains controversial. During the subacute stage, hand training is likely to be the most useful. To establish whether robot active assisted therapies provides any additional motor recovery for the hand when administered during the subacute stage (robot based therapies for hand recovery will show significant differences at subacute stages. A randomized clinical trial. A between subjects randomized controlled trial was carried out on subacute stroke patients (n = 17) comparing robot active assisted therapy (RT) with a classical occupational therapy (OT). Both groups received 40 sessions ensuring at least 300 repetitions per session. Treatment duration was (mean ± std) 2.18 ± 1.25 months for the control group and 2.44 ± 0.88 months for the study group. The primary outcome was motor dexterity changes assessed with the Fugl-Meyer (FMA) and the Motricity Index (MI). Both groups (OT: n = 8; RT: n = 9) exhibited significant improvements over time (Non-parametric Cliff's delta-within effect sizes: dwOT-FMA = 0.5, dwOT-MI = 0.5, dwRT-FMA = 1, dwRT-MI = 1). Regarding differences between the therapies; the Fugl-Meyer score indicated a significant advantage for the hand training with the robot (FMA hand: WRS: W = 8, p hand prehension for RT with respect to OT but failed to reach significance (MI prehension: W = 17.5, p = 0.080). No harm occurred. Robotic therapies may be useful during the subacute stages of stroke - both endpoints (FM hand and MI prehension) showed the expected trend with bigger effect size for the robotic intervention. Additional benefit of the robotic therapy over the control therapy was only significant when the difference was measured with FM, demanding further investigation with larger samples. Implications of this study are important for decision making during therapy administration and resource allocation. Copyright © 2016 Hanley

  6. Comparison of three-dimensional, assist-as-needed robotic arm/hand movement training provided with Pneu-WREX to conventional tabletop therapy after chronic stroke.

    Science.gov (United States)

    Reinkensmeyer, David J; Wolbrecht, Eric T; Chan, Vicky; Chou, Cathy; Cramer, Steven C; Bobrow, James E

    2012-11-01

    Robot-assisted movement training can help individuals with stroke reduce arm and hand impairment, but robot therapy is typically only about as effective as conventional therapy. Refining the way that robots assist during training may make them more effective than conventional therapy. Here, the authors measured the therapeutic effect of a robot that required individuals with a stroke to achieve virtual tasks in three dimensions against gravity. The robot continuously estimated how much assistance patients needed to perform the tasks and provided slightly less assistance than needed to reduce patient slacking. Individuals with a chronic stroke (n = 26; baseline upper limb Fugl-Meyer score, 23 ± 8) were randomized into two groups and underwent 24 one-hour training sessions over 2 mos. One group received the assist-as-needed robot training and the other received conventional tabletop therapy with the supervision of a physical therapist. Training helped both groups significantly reduce their motor impairment, as measured by the primary outcome measure, the Fugl-Meyer score, but the improvement was small (3.0 ± 4.9 points for robot therapy vs. 0.9 ± 1.7 for conventional therapy). There was a trend for greater reduction for the robot-trained group (P = 0.07). The robot group largely sustained this gain at the 3-mo follow-up. The robot-trained group also experienced significant improvements in Box and Blocks score and hand grip strength, whereas the control group did not, but these improvements were not sustained at follow-up. In addition, the robot-trained group showed a trend toward greater improvement in sensory function, as measured by the Nottingham Sensory Test (P = 0.06). These results suggest that in patients with chronic stroke and moderate-severe deficits, assisting in three-dimensional virtual tasks with an assist-as-needed controller may make robotic training more effective than conventional tabletop training.

  7. Robotic resection of the liver caudate lobe: technical description and initial consideration.

    Science.gov (United States)

    Marino, Marco Vito; Glagolieva, Anastasiia; Guarrasi, Domenico

    2018-03-01

    Firstly described in 2002, the robotic liver surgery has not spread widely due to its high cost and the lack of a standardized training program. Still being considered as a 'development in progress' technique, it has however a potential to overcome the traditional limitations of the laparoscopic approach in liver interventions. We analyzed the postoperative outcomes of 10 patients who had undergone robotic partial resection of the caudate lobe (Spiegel lobe) from March 2014 to May 2016 in order to evaluate the advantages of robotic technique in hands of a young surgeon. The mean operative time was 258min (150-522) and the estimated blood loss 137ml (50-359), in none of the cases a blood transfusion was required. No patient underwent a conversion to open surgery; the overall morbidity was 2/10 (20%) and all the complications occurred (biliary fistula and pleural effusion) did not require a surgical revision. At histological examination, the mean tumour size was 2.63cm and we achieved R0-resection rate of 100%. The 90-day mortality rate was null. The 1-year overall and disease free-survival rates were 100% and 80%, respectively. Despite several concerns regarding the cost-effectiveness, a fully robotic partial resection of caudate lobe is an advantageous, implementable technique providing promising short-term postoperative outcomes with acceptable benefit-risk profile. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. A prospective comparison of patient body image after robotic thyroidectomy and conventional open thyroidectomy in patients with papillary thyroid carcinoma.

    Science.gov (United States)

    Lee, Sohee; Kim, Ha Yan; Lee, Cho Rok; Park, Seulkee; Son, Haiyoung; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Chung, Woong Youn; Park, Cheong Soo

    2014-07-01

    Body image is associated with self-esteem and identity and has a close relationship with quality of life (QoL). We compared the impact of surgical scars on the patient's perception of body image between conventional open thyroidectomy (OT) and robotic thyroidectomy (RT) in female papillary thyroid carcinoma patients. From October 2009 to December 2010, we enrolled prospectively 116 papillary thyroid carcinoma patients who underwent total thyroidectomy at the Yonsei University Health System (Seoul, Korea). Of these 116 patients, 56 had OT and 60 RT. Their scars were assessed using the Vancouver Scar Scale (VSS), and psychometric properties were evaluated using the Body Image Scale (BIS) questionnaire postoperatively. Both groups were compared using cross-sectional and time-series methods. Mean age was significantly younger in the RT group. Regarding scar quality, the OT group showed superiority in scar pigmentation and the total VSS score during the early postoperative period, but the VSS score improved over time and was similar between both groups at 9 months. The RT group had better scores regarding most of the BIS items, a trend that remained relatively constant over time. In patients with noticeable scars (VSS ≥ 2) at 9 months, the RT group had better BIS scores regarding almost all items, including "self-conscious," "physical attractiveness," "feeling of less feminine," "sexual attractiveness," "dissatisfaction with body, scar and appearance when dressed," and "avoidance of people due to appearance." RT provides a better self-body image and improves QoL compared with conventional OT by avoiding a noticeable cervical scar. Copyright © 2014 Mosby, Inc. All rights reserved.

  9. Effects of intensive arm training with the rehabilitation robot ARMin II in chronic stroke patients: four single-cases

    Directory of Open Access Journals (Sweden)

    Nef Tobias

    2009-12-01

    Full Text Available Abstract Background Robot-assisted therapy offers a promising approach to neurorehabilitation, particularly for severely to moderately impaired stroke patients. The objective of this study was to investigate the effects of intensive arm training on motor performance in four chronic stroke patients using the robot ARMin II. Methods ARMin II is an exoskeleton robot with six degrees of freedom (DOF moving shoulder, elbow and wrist joints. Four volunteers with chronic (≥ 12 months post-stroke left side hemi-paresis and different levels of motor severity were enrolled in the study. They received robot-assisted therapy over a period of eight weeks, three to four therapy sessions per week, each session of one hour. Patients 1 and 4 had four one-hour training sessions per week and patients 2 and 3 had three one-hour training sessions per week. Primary outcome variable was the Fugl-Meyer Score of the upper extremity Assessment (FMA, secondary outcomes were the Wolf Motor Function Test (WMFT, the Catherine Bergego Scale (CBS, the Maximal Voluntary Torques (MVTs and a questionnaire about ADL-tasks, progress, changes, motivation etc. Results Three out of four patients showed significant improvements (p Conclusion Data clearly indicate that intensive arm therapy with the robot ARMin II can significantly improve motor function of the paretic arm in some stroke patients, even those in a chronic state. The findings of the study provide a basis for a subsequent controlled randomized clinical trial.

  10. Brief biomechanical analysis on the walking of spinal cord injury patients with a lower limb exoskeleton robot.

    Science.gov (United States)

    Jung, Jun-Young; Park, Hyunsub; Yang, Hyun-Dae; Chae, Mingi

    2013-06-01

    This paper presents a brief biomechanical analysis on the walking behavior of spinal cord injury (SCI) patients. It is known that SCI patients who have serious injuries to their spines cannot walk, and hence, several walking assistance lower limb exoskeleton robots have been proposed whose assistance abilities are shown to be well customized. However, these robots are not yet fully helpful to all SCI patients for several reasons. To overcome these problems, an exact analysis and evaluation of the restored walking function while the exoskeleton is worn is important. In this work, walking behavior of SCI patients wearing the rehabilitation of brain injuries (ROBIN) lower-limb walking assistant exoskeleton was analyzed in comparison to that of normal unassisted walking. The analysis method and results presented herein can be used by other researchers to improve their robots.

  11. Effect of Robot-Assisted Game Training on Upper Extremity Function in Stroke Patients

    Science.gov (United States)

    2017-01-01

    Objective To determine the effects of combining robot-assisted game training with conventional upper extremity rehabilitation training (RCT) on motor and daily functions in comparison with conventional upper extremity rehabilitation training (OCT) in stroke patients. Methods Subjects were eligible if they were able to perform the robot-assisted game training and were divided randomly into a RCT and an OCT group. The RCT group performed one daily session of 30 minutes of robot-assisted game training with a rehabilitation robot, plus one daily session of 30 minutes of conventional rehabilitation training, 5 days a week for 2 weeks. The OCT group performed two daily sessions of 30 minutes of conventional rehabilitation training. The effects of training were measured by a Manual Function Test (MFT), Manual Muscle Test (MMT), Korean version of the Modified Barthel Index (K-MBI) and a questionnaire about satisfaction with training. These measurements were taken before and after the 2-week training. Results Both groups contained 25 subjects. After training, both groups showed significant improvements in motor and daily functions measured by MFT, MMT, and K-MBI compared to the baseline. Both groups demonstrated similar training effects, except motor power of wrist flexion. Patients in the RCT group were more satisfied than those in the OCT group. Conclusion There were no significant differences in changes in most of the motor and daily functions between the two types of training. However, patients in the RCT group were more satisfied than those in the OCT group. Therefore, RCT could be a useful upper extremity rehabilitation training method. PMID:28971037

  12. Effect of Robot-Assisted Game Training on Upper Extremity Function in Stroke Patients.

    Science.gov (United States)

    Lee, Kyeong Woo; Kim, Sang Beom; Lee, Jong Hwa; Lee, Sook Joung; Kim, Jin Wan

    2017-08-01

    To determine the effects of combining robot-assisted game training with conventional upper extremity rehabilitation training (RCT) on motor and daily functions in comparison with conventional upper extremity rehabilitation training (OCT) in stroke patients. Subjects were eligible if they were able to perform the robot-assisted game training and were divided randomly into a RCT and an OCT group. The RCT group performed one daily session of 30 minutes of robot-assisted game training with a rehabilitation robot, plus one daily session of 30 minutes of conventional rehabilitation training, 5 days a week for 2 weeks. The OCT group performed two daily sessions of 30 minutes of conventional rehabilitation training. The effects of training were measured by a Manual Function Test (MFT), Manual Muscle Test (MMT), Korean version of the Modified Barthel Index (K-MBI) and a questionnaire about satisfaction with training. These measurements were taken before and after the 2-week training. Both groups contained 25 subjects. After training, both groups showed significant improvements in motor and daily functions measured by MFT, MMT, and K-MBI compared to the baseline. Both groups demonstrated similar training effects, except motor power of wrist flexion. Patients in the RCT group were more satisfied than those in the OCT group. There were no significant differences in changes in most of the motor and daily functions between the two types of training. However, patients in the RCT group were more satisfied than those in the OCT group. Therefore, RCT could be a useful upper extremity rehabilitation training method.

  13. Resident education in robotic-assisted vertical sleeve gastrectomy: outcomes and cost-analysis of 411 consecutive cases.

    Science.gov (United States)

    Ecker, Brett L; Maduka, Richard; Ramdon, Andre; Dempsey, Daniel T; Dumon, Kristoffel R; Williams, Noel N

    2016-02-01

    Robotic technology is increasingly prevalent in bariatric surgery, yet there are national deficiencies in exposure of surgical residents to robotic techniques. The purpose of this study is to accurately characterize the perioperative outcomes of a resident teaching model using the robotic-assisted sleeve gastrectomy. University Hospital. We identified 411 consecutive patients who underwent robotic sleeve gastrectomy at our institution from a prospectively maintained administrative database. Perioperative morbidity, operative time, and supply cost of the procedure were analyzed. Mean operative time was 96.4±24.9 minutes; mean robot usage time was 63.9 minutes (range 30.0-122.0 min). Ninety-day morbidities included reoperation (0.72%), major bleeding complications (0.48%), staple line leak (0.24%), stricture (0.97%), need for blood transfusion (3.86%), surgical site infection (1.69%), deep vein thrombosis (0.48%), and pulmonary embolism (0.48%). Mortality was nil. The resident cohort achieved operative time plateaus after five consecutive cases. Subset analysis for fiscal year 2014 demonstrated significantly increased supply cost for robotic sleeve gastrectomy compared with its laparoscopic equivalent. Robotic-assisted sleeve gastrectomy can be instituted as a model for resident robotic education with rates of morbidity and operative times equivalent to historical laparoscopic controls. The robot's enhanced ergonomics and its opportunity for resident education must be weighed against its increased supply cost. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  14. 30-day hospital readmission after robotic partial nephrectomy--are we prepared for Medicare readmission reduction program?

    Science.gov (United States)

    Brandao, Luis Felipe; Zargar, Homayoun; Laydner, Humberto; Akca, Oktay; Autorino, Riccardo; Ko, Oliver; Samarasekera, Dinesh; Li, Jianbo; Rabets, John; Krishnan, Jayram; Haber, Georges-Pascal; Kaouk, Jihad; Stein, Robert J

    2014-09-01

    After CMS introduced the concept of the Hospital Readmissions Reduction Program, hospitals and health care centers became financially penalized for exceeding specific readmission rates. We retrospectively reviewed our institutional review board approved database of patients undergoing robotic partial nephrectomy at our institution and included in our analysis patients who were readmitted to any hospital as an inpatient stay within 30 days from discharge home after robotic partial nephrectomy. From March 2006 to March 2013 a total of 627 patients underwent robotic partial nephrectomy at our center and 28 (4.46%) were readmitted within 30 days of surgery. Postoperative bleeding was responsible for 8 (28.5%) readmissions. Pulmonary embolism was reported in 3 cases and retroperitoneal abscess was diagnosed in 2. Urinary leak requiring surgical intervention developed in 2 patients, pneumonia was diagnosed in 2 and 2 patients were readmitted for chest pain. Overall 9 (32.1%) patients presented with major complications requiring intervention. On multivariable analysis Charlson comorbidity index score was the only factor significantly associated with a higher 30-day readmission rate (p = 0.03). If the Charlson score was 5 or greater the chance of hospital readmission would be 2.7 times higher. Increased comorbidity, specifically a Charlson score of 5 or greater, was the only significant predictor of a higher incidence of 30-day readmission. This information can be useful in counseling patients regarding robotic partial nephrectomy and in determining baseline rates if CMS expands the number of conditions they evaluate for excess 30-day readmissions. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

    International Nuclear Information System (INIS)

    Riga, Celia V.; Bicknell, Colin D.; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-01-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  16. Surrogate pregnancy in a patient who underwent radical hysterectomy and bilateral transposition of ovaries.

    Science.gov (United States)

    Azem, Foad; Yovel, Israel; Wagman, Israel; Kapostiansky, Rita; Lessing, Joseph B; Amit, Ami

    2003-05-01

    To evaluate IVF-surrogate pregnancy in a patient with ovarian transposition after radical hysterectomy for carcinoma of the cervix. Case report. A maternity hospital in Tel Aviv that is a major tertiary care and referral center. A 29-year-old woman who underwent Wertheim's hysterectomy for carcinoma of the uterine cervix and ovarian transposition before total pelvic irradiation. Standard IVF treatment, transabdominal oocyte retrieval, and transfer to surrogate mother. Outcome of IVF cycle. A twin pregnancy in the first cycle. This is the second reported case of controlled ovarian stimulation and oocyte retrieval performed on a transposed ovary.

  17. Clinical Outcomes of patients with coronary artery disease who underwent FFR evaluation of intermediate coronary lesionS– COFFRS study

    Directory of Open Access Journals (Sweden)

    Srinivasa Prasad

    2017-07-01

    Conclusion: In our experience, MACE events were not higher in patients with FFR > 0.8 and kept under medical therapy and were similarly lower in patients with FFR ≤0.8 and underwent revascularisation (p = 0.73. Also MACE events were higher in patients with FFR ≤ 0.8 and did not undergo revascularisation compared to other two appropriately treated groups (p = 0.03. FFR based revascularization decision appears to be a safe strategy in Indian patients.

  18. Next generation light robotic

    DEFF Research Database (Denmark)

    Villangca, Mark Jayson; Palima, Darwin; Banas, Andrew Rafael

    2017-01-01

    -assisted surgery imbibes surgeons with superhuman abilities and gives the expression “surgical precision” a whole new meaning. Still in its infancy, much remains to be done to improve human-robot collaboration both in realizing robots that can operate safely with humans and in training personnel that can work......Conventional robotics provides machines and robots that can replace and surpass human performance in repetitive, difficult, and even dangerous tasks at industrial assembly lines, hazardous environments, or even at remote planets. A new class of robotic systems no longer aims to replace humans...... with so-called automatons but, rather, to create robots that can work alongside human operators. These new robots are intended to collaborate with humans—extending their abilities—from assisting workers on the factory floor to rehabilitating patients in their homes. In medical robotics, robot...

  19. [Robotics in pediatric surgery].

    Science.gov (United States)

    Camps, J I

    2011-10-01

    Despite the extensive use of robotics in the adult population, the use of robotics in pediatrics has not been well accepted. There is still a lack of awareness from pediatric surgeons on how to use the robotic equipment, its advantages and indications. Benefit is still controversial. Dexterity and better visualization of the surgical field are one of the strong values. Conversely, cost and a lack of small instruments prevent the use of robotics in the smaller patients. The aim of this manuscript is to present the controversies about the use of robotics in pediatric surgery.

  20. Future of robotic surgery.

    Science.gov (United States)

    Lendvay, Thomas Sean; Hannaford, Blake; Satava, Richard M

    2013-01-01

    In just over a decade, robotic surgery has penetrated almost every surgical subspecialty and has even replaced some of the most commonly performed open oncologic procedures. The initial reports on patient outcomes yielded mixed results, but as more medical centers develop high-volume robotics programs, outcomes appear comparable if not improved for some applications. There are limitations to the current commercially available system, and new robotic platforms, some designed to compete in the current market and some to address niche surgical considerations, are being developed that will change the robotic landscape in the next decade. Adoption of these new systems will be dependent on overcoming barriers to true telesurgery that range from legal to logistical. As additional surgical disciplines embrace robotics and open surgery continues to be replaced by robotic approaches, it will be imperative that adequate education and training keep pace with technology. Methods to enhance surgical performance in robotics through the use of simulation and telementoring promise to accelerate learning curves and perhaps even improve surgical readiness through brief virtual-reality warm-ups and presurgical rehearsal. All these advances will need to be carefully and rigorously validated through not only patient outcomes, but also cost efficiency.

  1. Feasibility and early outcomes of robotic-assisted laparoscopic Mitrofanoff appendicovesicostomy in patients with prune belly syndrome.

    Science.gov (United States)

    Wille, Mark A; Jayram, Gautam; Gundeti, Mohan S

    2012-01-01

    To evaluate the feasibility and report our initial experience with Robotic-Assisted Laparoscopic Mitrofanoff Appendicovesicostomy (RALMA) in patients with prune belly syndrome. The Mitrofanoff appendicovesicostomy procedure uses the appendix to create an easily accessible continent, catheterizable channel into the urinary bladder. Historically, the procedure is performed by an open surgical approach in prune belly patients. We describe our initial experience herein. Between October 2008 and February 2010 three patients with prune belly syndrome underwent RALMA. The appendicovesicostomy anastomosis was performed on the anterior bladder wall and the stoma was brought to the umbilical site or right lower quadrant. At least 4 cm of detrusor backing was ensured. The appendicovesicostomy stent was left in place for 4 weeks postoperatively before initiation of catheterization. Mean age at surgery was 9.7 years (range 5-14 years). Blood loss volume was 20 mL in each case. Overall mean operative time was 352 min (range 319-402 min). There were no intraoperative complications and no open conversions. There was one postoperative complication in the form of wound infection. All patients are catheterizing their stomas and are continent at an average follow-up of 14.7 months (range 5-21 months). In our initial experience, RALMA is a feasible option with encouraging early experience for creating a continent catheterizable channel into the urinary bladder in patients with prune belly syndrome. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  2. Assessment of Robotic Patient Simulators for Training in Manual Physical Therapy Examination Techniques

    Science.gov (United States)

    Ishikawa, Shun; Okamoto, Shogo; Isogai, Kaoru; Akiyama, Yasuhiro; Yanagihara, Naomi; Yamada, Yoji

    2015-01-01

    Robots that simulate patients suffering from joint resistance caused by biomechanical and neural impairments are used to aid the training of physical therapists in manual examination techniques. However, there are few methods for assessing such robots. This article proposes two types of assessment measures based on typical judgments of clinicians. One of the measures involves the evaluation of how well the simulator presents different severities of a specified disease. Experienced clinicians were requested to rate the simulated symptoms in terms of severity, and the consistency of their ratings was used as a performance measure. The other measure involves the evaluation of how well the simulator presents different types of symptoms. In this case, the clinicians were requested to classify the simulated resistances in terms of symptom type, and the average ratios of their answers were used as performance measures. For both types of assessment measures, a higher index implied higher agreement among the experienced clinicians that subjectively assessed the symptoms based on typical symptom features. We applied these two assessment methods to a patient knee robot and achieved positive appraisals. The assessment measures have potential for use in comparing several patient simulators for training physical therapists, rather than as absolute indices for developing a standard. PMID:25923719

  3. Assessment of robotic patient simulators for training in manual physical therapy examination techniques.

    Directory of Open Access Journals (Sweden)

    Shun Ishikawa

    Full Text Available Robots that simulate patients suffering from joint resistance caused by biomechanical and neural impairments are used to aid the training of physical therapists in manual examination techniques. However, there are few methods for assessing such robots. This article proposes two types of assessment measures based on typical judgments of clinicians. One of the measures involves the evaluation of how well the simulator presents different severities of a specified disease. Experienced clinicians were requested to rate the simulated symptoms in terms of severity, and the consistency of their ratings was used as a performance measure. The other measure involves the evaluation of how well the simulator presents different types of symptoms. In this case, the clinicians were requested to classify the simulated resistances in terms of symptom type, and the average ratios of their answers were used as performance measures. For both types of assessment measures, a higher index implied higher agreement among the experienced clinicians that subjectively assessed the symptoms based on typical symptom features. We applied these two assessment methods to a patient knee robot and achieved positive appraisals. The assessment measures have potential for use in comparing several patient simulators for training physical therapists, rather than as absolute indices for developing a standard.

  4. Assessment of robotic patient simulators for training in manual physical therapy examination techniques.

    Science.gov (United States)

    Ishikawa, Shun; Okamoto, Shogo; Isogai, Kaoru; Akiyama, Yasuhiro; Yanagihara, Naomi; Yamada, Yoji

    2015-01-01

    Robots that simulate patients suffering from joint resistance caused by biomechanical and neural impairments are used to aid the training of physical therapists in manual examination techniques. However, there are few methods for assessing such robots. This article proposes two types of assessment measures based on typical judgments of clinicians. One of the measures involves the evaluation of how well the simulator presents different severities of a specified disease. Experienced clinicians were requested to rate the simulated symptoms in terms of severity, and the consistency of their ratings was used as a performance measure. The other measure involves the evaluation of how well the simulator presents different types of symptoms. In this case, the clinicians were requested to classify the simulated resistances in terms of symptom type, and the average ratios of their answers were used as performance measures. For both types of assessment measures, a higher index implied higher agreement among the experienced clinicians that subjectively assessed the symptoms based on typical symptom features. We applied these two assessment methods to a patient knee robot and achieved positive appraisals. The assessment measures have potential for use in comparing several patient simulators for training physical therapists, rather than as absolute indices for developing a standard.

  5. The immediate intervention effects of robotic training in patients after anterior cruciate ligament reconstruction

    OpenAIRE

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Ye, Miao

    2016-01-01

    [Purpose] The purpose of this study was to examine the immediate effects of robot-assisted therapy on functional activity level after anterior cruciate ligament reconstruction. [Subjects and Methods] Participants included 10 patients (8 males and 2 females) following anterior cruciate ligament reconstruction. The subjects participated in robot-assisted therapy and treadmill exercise on different days. The Timed Up-and-Go test, Functional Reach Test, surface electromyography of the vastus late...

  6. Impact of high-density lipoprotein 3 cholesterol subfraction on periprocedural myocardial injury in patients who underwent elective percutaneous coronary intervention.

    Science.gov (United States)

    Harada, Kazuhiro; Kikuchi, Ryosuke; Suzuki, Susumu; Tanaka, Akihito; Aoki, Toshijiro; Iwakawa, Naoki; Kojima, Hiroki; Hirayama, Kenshi; Mitsuda, Takayuki; Sumi, Takuya; Negishi, Yosuke; Ishii, Hideki; Murohara, Toyoaki

    2018-02-02

    Periprocedural myocardial injury (PMI) is a major complication of percutaneous coronary intervention (PCI) and is associated with atherosclerotic coronary plaque and worse clinical outcomes. High-density lipoprotein cholesterol (HDL-C) is a protective factor for cardiovascular disease. However, the role of HDL-C subfractions, such as HDL2 cholesterol (HDL2-C) or HDL3 cholesterol (HDL3-C), in cardiovascular disease remains unclear. The purpose of the study was to investigate the relationship between HDL2-C and HDL3-C subfractions and the incidence of PMI in patients who underwent elective PCI. We enrolled 129 patients who underwent elective PCI for stable angina pectoris. PMI was defined as an increase in high-sensitivity troponin T levels > 5 times the upper normal limit (> 0.070 ng/mL) at 24 h after PCI. Serum HDL-C subfractions (HDL2-C and HDL3-C) were assessed using ultracentrifugation in patients with and those without PMI. HDL3-C levels were significantly lower in patients with PMI than in those without (15.1 ± 3.0 mg/dL vs. 16.4 ± 2.9 mg/dL, p = 0.016) and had an independent and inverse association with PMI (odds ratio, 0.86; 95% confidence interval, 0.74-0.99; p = 0.038). When divided by the cut-off value of HDL3-C for PMI (14.3 mg/dL), the incidence of PMI was significantly higher in low HDL3-C patients than in high HDL3-C patients (51.2% vs. 30.2%, p = 0.020). HDL3-C was an independent inverse predictor of PMI in patients who underwent elective PCI.

  7. Correlation between location of transposed ovary and function in cervical cancer patients who underwent radical hysterectomy.

    Science.gov (United States)

    Yoon, Aera; Lee, Yoo-Young; Park, Won; Huh, Seung Jae; Choi, Chel Hun; Kim, Tae-Joong; Lee, Jeong-Won; Kim, Byoung-Gie; Bae, Duk-Soo

    2015-05-01

    The study investigated the association between the location of transposed ovaries and posttreatment ovarian function in patients with early cervical cancer (IB1-IIA) who underwent radical hysterectomy and ovarian transposition with or without adjuvant therapies. Retrospective medical records were reviewed to enroll the patients with early cervical cancer who underwent ovarian transposition during radical hysterectomy at Samsung Medical Center between July 1995 and July 2012. Serum follicle-stimulating hormone (FSH) level was used as a surrogate marker for ovarian function. Twenty-one patients were enrolled. The median age and body mass index (BMI) were 31 years (range, 24-39 years) and 21.3 kg/m² (range, 17.7-31.2 kg/m²), respectively. The median serum FSH level after treatment was 7.9 mIU/mL (range, 2.4-143.4 mIU/mL). The median distance from the iliac crest to transposed ovaries on erect plain abdominal x-ray was 0.5 cm (range, -2.7 to 5.2 cm). In multivariate analysis, posttreatment serum FSH levels were significantly associated with the location of transposed ovaries (β = -8.1, P = 0.032), concurrent chemoradiation (CCRT) as an adjuvant therapy (β = 71.08, P = 0.006), and BMI before treatment (underweight: β = -59.93, P = 0.05; overweight: β = -40.62, P = 0.041). Location of transposed ovaries, adjuvant CCRT, and BMI before treatment may be associated with ovarian function after treatment. We suggest that ovaries should be transposed as highly as possible during radical hysterectomy to preserve ovarian function in young patients with early cervical cancer who might be a candidate for adjuvant CCRT and who have low BMI before treatment.

  8. Towards cybernetic surgery: robotic and augmented reality-assisted liver segmentectomy.

    Science.gov (United States)

    Pessaux, Patrick; Diana, Michele; Soler, Luc; Piardi, Tullio; Mutter, Didier; Marescaux, Jacques

    2015-04-01

    Augmented reality (AR) in surgery consists in the fusion of synthetic computer-generated images (3D virtual model) obtained from medical imaging preoperative workup and real-time patient images in order to visualize unapparent anatomical details. The 3D model could be used for a preoperative planning of the procedure. The potential of AR navigation as a tool to improve safety of the surgical dissection is outlined for robotic hepatectomy. Three patients underwent a fully robotic and AR-assisted hepatic segmentectomy. The 3D virtual anatomical model was obtained using a thoracoabdominal CT scan with a customary software (VR-RENDER®, IRCAD). The model was then processed using a VR-RENDER® plug-in application, the Virtual Surgical Planning (VSP®, IRCAD), to delineate surgical resection planes including the elective ligature of vascular structures. Deformations associated with pneumoperitoneum were also simulated. The virtual model was superimposed to the operative field. A computer scientist manually registered virtual and real images using a video mixer (MX 70; Panasonic, Secaucus, NJ) in real time. Two totally robotic AR segmentectomy V and one segmentectomy VI were performed. AR allowed for the precise and safe recognition of all major vascular structures during the procedure. Total time required to obtain AR was 8 min (range 6-10 min). Each registration (alignment of the vascular anatomy) required a few seconds. Hepatic pedicle clamping was never performed. At the end of the procedure, the remnant liver was correctly vascularized. Resection margins were negative in all cases. The postoperative period was uneventful without perioperative transfusion. AR is a valuable navigation tool which may enhance the ability to achieve safe surgical resection during robotic hepatectomy.

  9. Multicenter review of robotic versus laparoscopic ventral hernia repair: is there a role for robotics?

    Science.gov (United States)

    Walker, Peter A; May, Audriene C; Mo, Jiandi; Cherla, Deepa V; Santillan, Monica Rosales; Kim, Steven; Ryan, Heidi; Shah, Shinil K; Wilson, Erik B; Tsuda, Shawn

    2018-04-01

    The utilization of robotic platforms for general surgery procedures such as hernia repair is growing rapidly in the United States. A limited amount of data are available evaluating operative outcomes in comparison to standard laparoscopic surgery. We completed a retrospective review comparing robotic and laparoscopic ventral hernia repair to provide safety and outcomes data to help design a future prospective trial design. A retrospective review of 215 patients undergoing ventral hernia repair (142 robotic and 73 laparoscopic) was completed at two large academic centers. Primary outcome measure evaluated was recurrence. Secondary outcomes included incidence of primary fascial closure, and surgical site occurrences. Propensity for treatment match comparison demonstrated that robotic repair was associated with a decreased incidence of recurrence (2.1 versus 4.2%, p robotic repair was associated with increased incidence of primary fascial closure (77.1 versus 66.7%, p robotic repairs were completed on patients with lower body mass index (28.1 ± 3.6 versus 34.2 ± 6.4, p robotic repair was associated with decreased recurrence and surgical site occurrence. However, the differences noted in the patient populations limit the interpretability of these results. As adoption of robotic ventral hernia repair increases, prospective trials need to be designed in order to investigate the efficacy, safety, and cost effectiveness of this evolving technique.

  10. A taxonomy for user-healthcare robot interaction.

    Science.gov (United States)

    Bzura, Conrad; Im, Hosung; Liu, Tammy; Malehorn, Kevin; Padir, Taskin; Tulu, Bengisu

    2012-01-01

    This paper evaluates existing taxonomies aimed at characterizing the interaction between robots and their users and modifies them for health care applications. The modifications are based on existing robot technologies and user acceptance of robotics. Characterization of the user, or in this case the patient, is a primary focus of the paper, as they present a unique new role as robot users. While therapeutic and monitoring-related applications for robots are still relatively uncommon, we believe they will begin to grow and thus it is important that the spurring relationship between robot and patient is well understood.

  11. Using Robots at Home to Support Patients With Chronic Obstructive Pulmonary Disease: Pilot Randomized Controlled Trial.

    Science.gov (United States)

    Broadbent, Elizabeth; Garrett, Jeff; Jepsen, Nicola; Li Ogilvie, Vickie; Ahn, Ho Seok; Robinson, Hayley; Peri, Kathryn; Kerse, Ngaire; Rouse, Paul; Pillai, Avinesh; MacDonald, Bruce

    2018-02-13

    Socially assistive robots are being developed for patients to help manage chronic health conditions such as chronic obstructive pulmonary disease (COPD). Adherence to medication and availability of rehabilitation are suboptimal in this patient group, which increases the risk of hospitalization. This pilot study aimed to investigate the effectiveness of a robot delivering telehealth care to increase adherence to medication and home rehabilitation, improve quality of life, and reduce hospital readmission compared with a standard care control group. At discharge from hospital for a COPD admission, 60 patients were randomized to receive a robot at home for 4 months or to a control group. Number of hospitalization days for respiratory admissions over the 4-month study period was the primary outcome. Medication adherence, frequency of rehabilitation exercise, and quality of life were also assessed. Implementation interviews as well as benefit-cost analysis were conducted. Intention-to-treat and per protocol analyses showed no significant differences in the number of respiratory-related hospitalizations between groups. The intervention group was more adherent to their long-acting inhalers (mean number of prescribed puffs taken per day=48.5%) than the control group (mean 29.5%, P=.03, d=0.68) assessed via electronic recording. Self-reported adherence was also higher in the intervention group after controlling for covariates (P=.04). The intervention group increased their rehabilitation exercise frequency compared with the control group (mean difference -4.53, 95% CI -7.16 to -1.92). There were no significant differences in quality of life. Of the 25 patients who had the robot, 19 had favorable attitudes. This pilot study suggests that a homecare robot can improve adherence to medication and increase exercise. Further research is needed with a larger sample size to further investigate effects on hospitalizations after improvements are made to the robots. The robots could be

  12. [Evaluation of the antithrombotic strategy in low thrombotic risk patients who underwent aortic valve replacement with a bioprosthesis].

    Science.gov (United States)

    Aceves-Velázquez, Eduardo; Vieyra-Herrera, Gerardo; Rodríguez-Chávez, Laura; Herrera-Alarcón, Valentín

    2017-07-16

    According to current guidelines, in patients without additional risk factors who have undergone aortic valve replacement with a bioprosthesis, anticoagulation in the first 3 months after surgery is still a matter of debate. According to current evidence, aspirin in low doses is a reasonable alternative to vitamin K antagonists (VKA). A comparison is made between the incidence of thrombotic and haemorrhagic complications in patients with low thrombotic risk who underwent aortic valve replacement with a bioprosthesis in the National Institute of Cardiology of Ignacio Chávez of Mexico. The hypothesis: aspirin as monotherapy has a beneficial effect compared to VKA. The studied patients were the low thrombotic risk patients who underwent aortic valve replacement with a bioprosthesis in the National Institute of Cardiology of Ignacio Chávez of Mexico from 2011 to 2015. The groups studied were: aspirin only, VKA only, and the combination of VKA plus aspirin. The patients were retrospectively followed-up for 12 months, and the thrombotic and haemorrhagic complications were documented. Of the 231 patients included in the study, only one patient in the VKA only group presented with a haemorrhagic complication. No thrombotic complications were observed. In the present study no thrombotic complications were observed in patients who did not receive anticoagulation in the first 3 months after an aortic valve replacement with a bioprosthesis after a follow up period of 12 months. This suggests that the use of aspirin only is safe during this period. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  13. Long-term interventions effects of robotic training on patients after anterior cruciate ligament reconstruction

    OpenAIRE

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Zhou, Yue; Gu, Rui; Ye, Miao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng

    2016-01-01

    [Purpose] The aim of this study was to examine the long-term interventions effects of robot-assisted therapy rehabilitation on functional activity levels after anterior cruciate ligament reconstruction. [Subjects and Methods] The subjects were 8 patients (6 males and 2 females) who received anterior cruciate ligament reconstruction. The subjects participated in robot-assisted therapy lasting for one month. The Timed Up-and-Go test, 10-Meter Walk test, Functional Reach Test, surface electromyo...

  14. Combined robotic transanal total mesorectal excision (R-taTME) and single-site plus one-port (R-SSPO) technique for ultra-low rectal surgery-initial experience with a new operation approach.

    Science.gov (United States)

    Kuo, Li-Jen; Ngu, James Chi-Yong; Tong, Yiu-Shun; Chen, Chia-Che

    2017-02-01

    Robot-assisted rectal surgery is gaining popularity, and robotic single-site surgery is also being explored clinically. We report our initial experience with robotic transanal total mesorectal excision (R-taTME) and radical proctectomy using the robotic single-site plus one-port (R-SSPO) technique for low rectal surgery. Between July 2015 and March 2016, 15 consecutive patients with ultra-low rectal lesions underwent R-taTME followed by radical proctectomy using the R-SSPO technique by a single surgeon. The clinical and pathological results were retrospectively analyzed. The median operative time was 473 (range, 335-569) min, and the estimated blood loss was 33 (range, 30-50) mL. The median number of lymph nodes harvested was 12 (range, 8-18). The median distal resection margin was 1.4 (range, 0.4-3.5) cm, and all patients had clear circumferential resection margins. We encountered a left ureteric transection intraoperatively in one patient, and another patient required reoperation for postoperative adhesive intestinal obstruction. There was no 30-day mortality. R-taTME followed by radical proctectomy using the R-SSPO technique for patients with low rectal lesions is technically feasible and safe without compromising oncologic outcomes. However, there were considerable limitations and a steep learning curve using current robotic technology.

  15. The immediate intervention effects of robotic training in patients after anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Ye, Miao

    2016-07-01

    [Purpose] The purpose of this study was to examine the immediate effects of robot-assisted therapy on functional activity level after anterior cruciate ligament reconstruction. [Subjects and Methods] Participants included 10 patients (8 males and 2 females) following anterior cruciate ligament reconstruction. The subjects participated in robot-assisted therapy and treadmill exercise on different days. The Timed Up-and-Go test, Functional Reach Test, surface electromyography of the vastus lateralis and vastus medialis, and maximal extensor strength of isokinetic movement of the knee joint were evaluated in both groups before and after the experiment. [Results] The results for the Timed Up-and-Go Test and the 10-Meter Walk Test improved in the robot-assisted rehabilitation group. Surface electromyography of the vastus medialis muscle showed significant increases in maximum and average discharge after the intervention. [Conclusion] The results suggest that walking ability and muscle strength can be improved by robotic training.

  16. The restoration of walking stereotype with robotic device in patients after knee replacement

    Directory of Open Access Journals (Sweden)

    E. S. Koneva

    2013-01-01

    Full Text Available The efficacy of the reconstruction of the external robotic walking (RRH on the device "Lokomat" in patients after total knee arthroplasty (TKA in the early postoperative period (priori. The patients were divided into two groups: the study group (n=112 in patients whose priori to train walk on robotic device (EDM and control group (n = 80, where the restoration was carried out in an active stereotype motoring instructor-led exercise therapy without use of mechanized equipment. Comparative analysis of the test results revealed more efficient recovery stereotype walk from the main group. In the analysis of the main group in the dynamics dinamoplantgrafii showed improvement in economic structure step, restoring the symmetry of the load while walking between the lower limbs, improved suspension function of the operated limb. According to the analysis parameter of the trajectory of migration center under the feet, we noted an increase in the effective axial load on the operated leg in the main group 1161.29 267.49 g/cm2 compared with the control group 460.28 52.42 g/cm2 (p ≤ 0,05. In the main group also showed a decrease of anxiety and increasing motivation. Conducted an X-ray - control the implanted joint in the long-term (12 months after surgery did not show any signs of instability in the case of prosthetic components. Thus, conducting robotic training walk in patients in the early postoperative period is an effective and safe method of rehabilitation.

  17. Robotics in surgery: is a robot necessary? For what?

    Science.gov (United States)

    Ross, Sharona B; Downs, Darrell; Saeed, Sabrina M; Dolce, John K; Rosemurgy, Alexander S

    2017-02-01

    Every operation can be categorized along a spectrum from "most invasive" to "least invasive", based on the approach(es) through which it is commonly undertaken. Operations that are considered "most invasive" are characterized by "open" approaches with a relatively high degree of morbidity, while operations that are considered "least invasive" are undertaken with minimally invasive techniques and are associated with relatively improved patient outcomes, including faster recovery times and fewer complications. Because of the potential for reduced morbidity, movement along the spectrum towards minimally invasive surgery (MIS) is associated with a host of salutary benefits and, as well, lower costs of patient care. Accordingly, the goal of all stakeholders in surgery should be to attain universal application of the most minimally invasive approaches. Yet the difficulty of performing minimally invasive operations has largely limited its widespread application in surgery, particularly in the context of complex operations (i.e., those requiring complex extirpation and/or reconstruction). Robotic surgery, however, may facilitate application of minimally invasive techniques requisite for particular operations. Enhancements in visualization and dexterity offered by robotic surgical systems allow busy surgeons to quickly gain proficiency in demanding techniques (e.g., pancreaticojejunostomy), within a short learning curve. That is not to say, however, that all operations undertaken with minimally invasive techniques require robotic technology. Herein, we attempt to define how surgeon skill, operative difficulty, patient outcomes, and cost factors determine when robotic technology should be reasonably applied to patient care in surgery.

  18. Augmented environments for the targeting of hepatic lesions during image-guided robotic liver surgery.

    Science.gov (United States)

    Buchs, Nicolas C; Volonte, Francesco; Pugin, François; Toso, Christian; Fusaglia, Matteo; Gavaghan, Kate; Majno, Pietro E; Peterhans, Matthias; Weber, Stefan; Morel, Philippe

    2013-10-01

    Stereotactic navigation technology can enhance guidance during surgery and enable the precise reproduction of planned surgical strategies. Currently, specific systems (such as the CAS-One system) are available for instrument guidance in open liver surgery. This study aims to evaluate the implementation of such a system for the targeting of hepatic tumors during robotic liver surgery. Optical tracking references were attached to one of the robotic instruments and to the robotic endoscopic camera. After instrument and video calibration and patient-to-image registration, a virtual model of the tracked instrument and the available three-dimensional images of the liver were displayed directly within the robotic console, superimposed onto the endoscopic video image. An additional superimposed targeting viewer allowed for the visualization of the target tumor, relative to the tip of the instrument, for an assessment of the distance between the tumor and the tool for the realization of safe resection margins. Two cirrhotic patients underwent robotic navigated atypical hepatic resections for hepatocellular carcinoma. The augmented endoscopic view allowed for the definition of an accurate resection margin around the tumor. The overlay of reconstructed three-dimensional models was also used during parenchymal transection for the identification of vascular and biliary structures. Operative times were 240 min in the first case and 300 min in the second. There were no intraoperative complications. The da Vinci Surgical System provided an excellent platform for image-guided liver surgery with a stable optic and instrumentation. Robotic image guidance might improve the surgeon's orientation during the operation and increase accuracy in tumor resection. Further developments of this technological combination are needed to deal with organ deformation during surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. tDCS and Robotics on Upper Limb Stroke Rehabilitation: Effect Modification by Stroke Duration and Type of Stroke.

    Science.gov (United States)

    Straudi, Sofia; Fregni, Felipe; Martinuzzi, Carlotta; Pavarelli, Claudia; Salvioli, Stefano; Basaglia, Nino

    2016-01-01

    Objective. The aim of this exploratory pilot study is to test the effects of bilateral tDCS combined with upper extremity robot-assisted therapy (RAT) on stroke survivors. Methods. We enrolled 23 subjects who were allocated to 2 groups: RAT + real tDCS and RAT + sham-tDCS. Each patient underwent 10 sessions (5 sessions/week) over two weeks. Outcome measures were collected before and after treatment: (i) Fugl-Meyer Assessment-Upper Extremity (FMA-UE), (ii) Box and Block Test (BBT), and (iii) Motor Activity Log (MAL). Results. Both groups reported a significant improvement in FMA-UE score after treatment (p robotics on motor function. Patients with chronic and subcortical stroke benefited more from the treatments than patients with acute and cortical stroke, who presented very small changes. Conclusion. The additional use of bilateral tDCS to RAT seems to have a significant beneficial effect depending on the duration and type of stroke. These results should be verified by additional confirmatory studies.

  20. Comparative study of short-term cardiovascular autonomic control in cardiac surgery patients who underwent coronary artery bypass grafting or correction of valvular heart disease.

    Science.gov (United States)

    Shvartz, Vladimir A; Kiselev, Anton R; Karavaev, Anatoly S; Vulf, Kristina A; Borovkova, Ekaterina I; Prokhorov, Mikhail D; Petrosyan, Andrey D; Bockeria, Olga L

    2018-01-01

    Introduction: Our aim was to perform a comparative study of short-term cardiovascular autonomic control in cardiac surgery patients who underwent coronary artery bypass grafting (CABG) or surgical correction of valvular heart disease (SCVHD ). Methods: The synchronous 15 minutes records of heart rate variability (HRV) and finger's photoplethysmographic waveform variability (PPGV) were performed in 42 cardiac surgery patients (12 women) aged 61.8 ± 8.6 years (mean ± standard deviation), who underwent CABG, and 36 patients (16 women) aged 54.2 ± 14.9 years, who underwent SCVHD , before surgery and in 5-7 days after surgery. Conventional time and frequency domain measures of HRV and index S of synchronization between the slow oscillations in PPGV and HRV were analyzed. We also calculated personal dynamics of these indices after surgery. Results: We found no differences ( Р > 0.05) in all studied autonomic indices (preoperative and post-surgery) between studied patients' groups, except for the preoperative heart rate, which was higher in patients who underwent SCVHD ( P = 0.013). We have shown a pronounced preoperative and post-surgery variability (magnitude of inter-quartile ranges) of all autonomic indices in studied patients. In the cluster analysis based on cardiovascular autonomic indices (preoperative and post-surgery), we divided all patients into two clusters (38 and 40 subjects) which did not differ in all clinical characteristics (except for the preoperative hematocrit, P = 0.038), index S, and all post-surgery HRV indices. First cluster (38 patients) had higher preoperative values of the HR, TP, HF, and HF%, and lower preoperative values of the LF% and LF/HF. Conclusion: The variability of cardiovascular autonomic indices in on-pump cardiac surgery patients (two characteristic clusters were identified based on preoperative indices) was not associated with their clinical characteristics and features of surgical procedure (including cardioplegia).

  1. Robotic surgery for rectal cancer: current immediate clinical and oncological outcomes.

    Science.gov (United States)

    Araujo, Sergio Eduardo Alonso; Seid, Victor Edmond; Klajner, Sidney

    2014-10-21

    Laparoscopic rectal surgery continues to be a challenging operation associated to a steep learning curve. Robotic surgical systems have dramatically changed minimally invasive surgery. Three-dimensional, magnified and stable view, articulated instruments, and reduction of physiologic tremors leading to superior dexterity and ergonomics. Therefore, robotic platforms could potentially address limitations of laparoscopic rectal surgery. It was aimed at reviewing current literature on short-term clinical and oncological (pathological) outcomes after robotic rectal cancer surgery in comparison with laparoscopic surgery. A systematic review was performed for the period 2002 to 2014. A total of 1776 patients with rectal cancer underwent minimally invasive robotic treatment in 32 studies. After robotic and laparoscopic approach to oncologic rectal surgery, respectively, mean operating time varied from 192-385 min, and from 158-297 min; mean estimated blood loss was between 33 and 283 mL, and between 127 and 300 mL; mean length of stay varied from 4-10 d; and from 6-15 d. Conversion after robotic rectal surgery varied from 0% to 9.4%, and from 0 to 22% after laparoscopy. There was no difference between robotic (0%-41.3%) and laparoscopic (5.5%-29.3%) surgery regarding morbidity and anastomotic complications (respectively, 0%-13.5%, and 0%-11.1%). Regarding immediate oncologic outcomes, respectively among robotic and laparoscopic cases, positive circumferential margins varied from 0% to 7.5%, and from 0% to 8.8%; the mean number of retrieved lymph nodes was between 10 and 20, and between 11 and 21; and the mean distal resection margin was from 0.8 to 4.7 cm, and from 1.9 to 4.5 cm. Robotic rectal cancer surgery is being undertaken by experienced surgeons. However, the quality of the assembled evidence does not support definite conclusions about most studies variables. Robotic rectal cancer surgery is associated to increased costs and operating time. It also seems to be

  2. Development and Implementation of an End-Effector Upper Limb Rehabilitation Robot for Hemiplegic Patients with Line and Circle Tracking Training

    Directory of Open Access Journals (Sweden)

    Yali Liu

    2017-01-01

    Full Text Available Numerous robots have been widely used to deliver rehabilitative training for hemiplegic patients to improve their functional ability. Because of the complexity and diversity of upper limb motion, customization of training patterns is one key factor during upper limb rehabilitation training. Most of the current rehabilitation robots cannot intelligently provide adaptive training parameters, and they have not been widely used in clinical rehabilitation. This article proposes a new end-effector upper limb rehabilitation robot, which is a two-link robotic arm with two active degrees of freedom. This work investigated the kinematics and dynamics of the robot system, the control system, and the realization of different rehabilitation therapies. We also explored the influence of constraint in rehabilitation therapies on interaction force and muscle activation. The deviation of the trajectory of the end effector and the required trajectory was less than 1 mm during the tasks, which demonstrated the movement accuracy of the robot. Besides, results also demonstrated the constraint exerted by the robot provided benefits for hemiplegic patients by changing muscle activation in the way similar to the movement pattern of the healthy subjects, which indicated that the robot can improve the patient’s functional ability by training the normal movement pattern.

  3. Robotized transcranial magnetic stimulation

    CERN Document Server

    Richter, Lars

    2014-01-01

    Presents new, cutting-edge algorithms for robot/camera calibration, sensor fusion and sensor calibration Explores the main challenges for accurate coil positioning, such as head motion, and outlines how active robotic motion compensation can outperform hand-held solutions Analyzes how a robotized system in medicine can alleviate concerns with a patient's safety, and presents a novel fault-tolerant algorithm (FTA) sensor for system safety

  4. Image-guided robotic surgery.

    Science.gov (United States)

    Marescaux, Jacques; Solerc, Luc

    2004-06-01

    Medical image processing leads to an improvement in patient care by guiding the surgical gesture. Three-dimensional models of patients that are generated from computed tomographic scans or magnetic resonance imaging allow improved surgical planning and surgical simulation that offers the opportunity for a surgeon to train the surgical gesture before performing it for real. These two preoperative steps can be used intra-operatively because of the development of augmented reality, which consists of superimposing the preoperative three-dimensional model of the patient onto the real intraoperative view. Augmented reality provides the surgeon with a view of the patient in transparency and can also guide the surgeon, thanks to the real-time tracking of surgical tools during the procedure. When adapted to robotic surgery, this tool tracking enables visual serving with the ability to automatically position and control surgical robotic arms in three dimensions. It is also now possible to filter physiologic movements such as breathing or the heart beat. In the future, by combining augmented reality and robotics, these image-guided robotic systems will enable automation of the surgical procedure, which will be the next revolution in surgery.

  5. Differences in recurrent prolapse at 1 year after total vs supracervical hysterectomy and robotic sacrocolpopexy.

    Science.gov (United States)

    Myers, Erinn M; Siff, Lauren; Osmundsen, Blake; Geller, Elizabeth; Matthews, Catherine A

    2015-04-01

    Optimal management of the cervix at the time of hysterectomy and sacrocolpopexy for primary uterovaginal prolapse is unknown. Our hypothesis was that recurrent prolapse at 1 year would be more likely after a supracervical robotic hysterectomy (SRH) compared with a total robotic hysterectomy (TRH) at the time of robotic sacrocolpopexy (RSCP) for uterovaginal prolapse. This was a retrospective cohort analysis of 83 women who underwent hysterectomy with RSCP over a 24-month period (40 with TRH and 43 with SRH). At 1 year post-procedure, subjects completed validated questionnaires regarding pelvic floor symptoms, sexual function, and global satisfaction, and underwent a pelvic examination to identify mesh exposure and evaluate pelvic floor support. Demographics of the two groups were similar, except for a higher mean body mass index in the TRH group (31.9 TRH vs 25.8 SRH kg/m(2), p measure of success was used (30 out of 40 [75 %] TRH vs 29 out of 43 [67.4 %] SRH, p = 0.45). Women who underwent an SRH were 2.8 times more likely to have a recurrent prolapse, ≥ stage II, at 1 year, compared with those who underwent a TRH, but when composite assessment scores were used there was no difference between the groups.

  6. Gastrointestinal stromal tumours of stomach: Robot-assisted excision with the da Vinci Surgical System regardless of size and location site.

    Science.gov (United States)

    Furbetta, Niccolo; Palmeri, Matteo; Guadagni, Simone; Di Franco, Gregorio; Gianardi, Desirée; Latteri, Saverio; Marciano, Emanuele; Moglia, Andrea; Cuschieri, Alfred; Di Candio, Giulio; Mosca, Franco; Morelli, Luca

    2018-03-23

    The role of minimally invasive surgery of gastrointestinal stromal tumours (GISTs) of the stomach remains uncertain especially for large and/or difficult located tumours. We are hereby presenting a single-centre series of robot-assisted resections using the da Vinci Surgical System (Si or Xi). Data of patients undergoing robot-assisted treatment of gastric GIST were retrieved from the prospectively collected institutional database and a retrospective analysis was performed. Patients were stratified according to size and location of the tumour. Difficult cases (DCs) were considered for size if tumour was> 50 mm and/or for location if the tumour was Type II, III or IV sec. Privette/Al-Thani classification. Between May 2010 and February 2017, 12 consecutive patients underwent robot-assisted treatment of GIST at our institution. DCs were 10/12 cases (83.3%), of which 6/10 (50%) for location, 2/10 (25%) for size and 2/10 (25%) for both. The da Vinci Si was used in 8 patients, of which 6 (75%) were DC, and the da Vinci Xi in 4, all of which (100%) were DC. In all patients, excision was by wedge resection. All lesions had microscopically negative resection margins. There was no conversion to open surgery, no tumour ruptures or spillage and no intraoperative complications. Our experience suggests a positive role of the robot da Vinci in getting gastric GIST removal with a conservative approach, regardless of size and location site. Comparative studies with a greater number of patients are necessary for a more robust assessment.

  7. The Three Laws of Neurorobotics: A Review on What Neurorehabilitation Robots Should Do for Patients and Clinicians.

    Science.gov (United States)

    Iosa, Marco; Morone, Giovanni; Cherubini, Andrea; Paolucci, Stefano

    Most studies and reviews on robots for neurorehabilitation focus on their effectiveness. These studies often report inconsistent results. This and many other reasons limit the credit given to these robots by therapists and patients. Further, neurorehabilitation is often still based on therapists' expertise, with competition among different schools of thought, generating substantial uncertainty about what exactly a neurorehabilitation robot should do. Little attention has been given to ethics. This review adopts a new approach, inspired by Asimov's three laws of robotics and based on the most recent studies in neurorobotics, for proposing new guidelines for designing and using robots for neurorehabilitation. We propose three laws of neurorobotics based on the ethical need for safe and effective robots, the redefinition of their role as therapist helpers, and the need for clear and transparent human-machine interfaces. These laws may allow engineers and clinicians to work closely together on a new generation of neurorobots.

  8. Full Robotic Colorectal Resections for Cancer Combined With Other Major Surgical Procedures: Early Experience With the da Vinci Xi.

    Science.gov (United States)

    Morelli, Luca; Di Franco, Gregorio; Guadagni, Simone; Palmeri, Matteo; Gianardi, Desirée; Bianchini, Matteo; Moglia, Andrea; Ferrari, Vincenzo; Caprili, Giovanni; D'Isidoro, Cristiano; Melfi, Franca; Di Candio, Giulio; Mosca, Franco

    2017-08-01

    The da Vinci Xi has been developed to overcome some of the limitations of the previous platform, thereby increasing the acceptance of its use in robotic multiorgan surgery. Between January 2015 and October 2015, 10 patients with synchronous tumors of the colorectum and others abdominal organs underwent robotic combined resections with the da Vinci Xi. Trocar positions respected the Universal Port Placement Guidelines provided by Intuitive Surgical for "left lower quadrant," with trocars centered on the umbilical area, or shifted 2 to 3 cm to the right or to the left, depending on the type of combined surgical procedure. All procedures were completed with the full robotic technique. Simultaneous procedures in same quadrant or left quadrant and pelvis, or left/right and upper, were performed with a single docking/single targeting approach; in cases of left/right quadrant or right quadrant/pelvis, we performed a dual-targeting operation. No external collisions or problems related to trocar positions were noted. No patient experienced postoperative surgical complications and the mean hospital stay was 6 days. The high success rate of full robotic colorectal resection combined with other surgical interventions for synchronous tumors, suggest the efficacy of the da Vinci Xi in this setting.

  9. Mobile app for human-interaction with sitter robots

    Science.gov (United States)

    Das, Sumit Kumar; Sahu, Ankita; Popa, Dan O.

    2017-05-01

    Human environments are often unstructured and unpredictable, thus making the autonomous operation of robots in such environments is very difficult. Despite many remaining challenges in perception, learning, and manipulation, more and more studies involving assistive robots have been carried out in recent years. In hospital environments, and in particular in patient rooms, there are well-established practices with respect to the type of furniture, patient services, and schedule of interventions. As a result, adding a robot into semi-structured hospital environments is an easier problem to tackle, with results that could have positive benefits to the quality of patient care and the help that robots can offer to nursing staff. When working in a healthcare facility, robots need to interact with patients and nurses through Human-Machine Interfaces (HMIs) that are intuitive to use, they should maintain awareness of surroundings, and offer safety guarantees for humans. While fully autonomous operation for robots is not yet technically feasible, direct teleoperation control of the robot would also be extremely cumbersome, as it requires expert user skills, and levels of concentration not available to many patients. Therefore, in our current study we present a traded control scheme, in which the robot and human both perform expert tasks. The human-robot communication and control scheme is realized through a mobile tablet app that can be customized for robot sitters in hospital environments. The role of the mobile app is to augment the verbal commands given to a robot through natural speech, camera and other native interfaces, while providing failure mode recovery options for users. Our app can access video feed and sensor data from robots, assist the user with decision making during pick and place operations, monitor the user health over time, and provides conversational dialogue during sitting sessions. In this paper, we present the software and hardware framework that

  10. Comparison of PSA value at last follow-up of patients who underwent low-dose rate brachytherapy and intensity-modulated radiation therapy for prostate cancer.

    Science.gov (United States)

    Tanaka, Nobumichi; Asakawa, Isao; Nakai, Yasushi; Miyake, Makito; Anai, Satoshi; Fujii, Tomomi; Hasegawa, Masatoshi; Konishi, Noboru; Fujimoto, Kiyohide

    2017-08-25

    To compare the PSA value at the last follow-up of patients who underwent prostate low-dose rate brachytherapy (LDR-BT) with that of patients who underwent intensity-modulated radiation therapy (IMRT). A total of 610 prostate cancer patients (cT1c-3bN0M0) were enrolled, and 445 of them underwent LDR-BT, while 165 received IMRT (74-76 Gy). The median follow-up period of these two groups was 75 months (LDR-BT) and 78 months (IMRT), respectively. We also evaluated the biochemical recurrence (BCR)-free rate using two definitions (Phoenix definition and PSA ≥ 0.2 ng/mL). The percentage of patients who achieved PSA LDR-BT group and 49.7% in the IMRT group (p LDR-BT group and 32.1% in the IMRT group (p LDR-BT groups was 89.5 and 95.0% (p LDR-BT groups, respectively (p LDR-BT was significantly lower than that of IMRT, and this result was particularly marked in patients with a normal testosterone level at the last follow-up.

  11. Use of an Automated Mobile Phone Messaging Robot in Postoperative Patient Monitoring.

    Science.gov (United States)

    Anthony, Chris A; Lawler, Ericka A; Ward, Christina M; Lin, Ines C; Shah, Apurva S

    2018-01-01

    Mobile phone messaging software robots allow clinicians and healthcare systems to communicate with patients without the need for human intervention. The purpose of this study was to (1) describe a method for communicating with patients postoperatively outside of the traditional healthcare setting by utilizing an automated software and mobile phone messaging platform and to (2) evaluate the first week of postoperative pain and opioid use after common ambulatory hand surgery procedures. The investigation was a prospective, multicenter investigation of patient-reported pain and opioid usage after ambulatory hand surgery. Inclusion criteria included any adult with a mobile phone capable of text messaging, who was undergoing a common ambulatory hand surgical procedure at one of three tertiary care institutions. Participants received daily, automated text messages inquiring about their pain level and how many tablets of prescription pain medication they had taken in the past 24 h. Initial 1-week response rate was assessed and compared between different patient demographics. Patient-reported pain and opioid use were also quantified for the first postoperative week. Statistical significance was set as p tablets of prescription opioid pain medication. We find that a mobile phone messaging software robot allows for effective data collection of postoperative pain and pain medication use. Patients undergoing common ambulatory hand procedures utilized an average of 16 tablets of opioid medication in the first postoperative week.

  12. Effect of visual distraction and auditory feedback on patient effort during robot-assisted movement training after stroke.

    Science.gov (United States)

    Secoli, Riccardo; Milot, Marie-Helene; Rosati, Giulio; Reinkensmeyer, David J

    2011-04-23

    Practicing arm and gait movements with robotic assistance after neurologic injury can help patients improve their movement ability, but patients sometimes reduce their effort during training in response to the assistance. Reduced effort has been hypothesized to diminish clinical outcomes of robotic training. To better understand patient slacking, we studied the role of visual distraction and auditory feedback in modulating patient effort during a common robot-assisted tracking task. Fourteen participants with chronic left hemiparesis from stroke, five control participants with chronic right hemiparesis and fourteen non-impaired healthy control participants, tracked a visual target with their arms while receiving adaptive assistance from a robotic arm exoskeleton. We compared four practice conditions: the baseline tracking task alone; tracking while also performing a visual distracter task; tracking with the visual distracter and sound feedback; and tracking with sound feedback. For the distracter task, symbols were randomly displayed in the corners of the computer screen, and the participants were instructed to click a mouse button when a target symbol appeared. The sound feedback consisted of a repeating beep, with the frequency of repetition made to increase with increasing tracking error. Participants with stroke halved their effort and doubled their tracking error when performing the visual distracter task with their left hemiparetic arm. With sound feedback, however, these participants increased their effort and decreased their tracking error close to their baseline levels, while also performing the distracter task successfully. These effects were significantly smaller for the participants who used their non-paretic arm and for the participants without stroke. Visual distraction decreased participants effort during a standard robot-assisted movement training task. This effect was greater for the hemiparetic arm, suggesting that the increased demands associated

  13. Randomized, sham-controlled trial based on transcranial direct current stimulation and wrist robot-assisted integrated treatment on subacute stroke patients: Intermediate results.

    Science.gov (United States)

    Mazzoleni, Stefano; Tran, Vi Do; Iardella, Laura; Dario, Paolo; Posteraro, Federico

    2017-07-01

    The main goal of this study is to analyse the effects of combined transcranial direct current stimulation (tDCS) and wrist robot-assisted therapy in subacute stroke patients. Twenty-four patients were included in this study and randomly assigned to the experimental (EG) or control group (CG). All participants performed wrist robot-assisted training a) in conjunction with tDCS (real stimulation for patients in EG) or b) without tDCS (sham stimulation for patients in CG). Clinical scales and kinematic parameters recorded by the robot were used for the assessment. Clinical outcome measures show a significant decrease in motor impairment after the treatment in both groups. Kinematic data show several significant improvements after the integrated therapy in both groups. However, no significant differences in both clinical outcome measures and kinematic parameters was found between two groups. The potential advantages of combined tDCS and wrist robot-assisted therapy in subacute stroke patients are still unclear.

  14. Outcomes of complex robot-assisted extravesical ureteral reimplantation in the pediatric population.

    Science.gov (United States)

    Arlen, Angela M; Broderick, Kristin M; Travers, Curtis; Smith, Edwin A; Elmore, James M; Kirsch, Andrew J

    2016-06-01

    While open ureteral reimplantation remains the gold standard for surgical treatment of vesicoureteral reflux (VUR), minimally invasive approaches offer potential benefits. This study evaluated the outcomes of children undergoing complex robot-assisted laparoscopic ureteral reimplantation (RALUR) for failed previous anti-reflux surgery, complex anatomy, or ureterovesical junction obstruction (UVJO), and compared them with patients undergoing open extravesical repair. Children undergoing complex RALUR or open extravesical ureteral reimplantation (OUR) were identified. Reimplantation was classified as complex if ureters: 1) had previous anti-reflux surgery, 2) required tapering and/or dismembering, or 3) had associated duplication or diverticulum. Seventeen children underwent complex RALUR during a 24-month period, compared with 41 OUR. The mean follow-up was 16.6 ± 6.5 months. The RALUR children were significantly older (9.3 ± 3.7 years) than the OUR patients (3.1 ± 2.7 years; P urinary tract infection compared with a single child (5.9%) undergoing RALUR (P = 1.00). There was no significant difference in complication rate between the two groups (12.2% OUR versus 11.8% RALUR; P = 1.00). A postoperative cystogram was performed in the majority of RALUR patients, with no persistent VUR detected, and one child (6.7%) was diagnosed with contralateral reflux. Reported VUR resolution rates following robot-assisted ureteral reimplantation are varied. In the present series, children undergoing RALUR following failed previous anti-reflux surgery, with complex anatomy, or UVJO experienced a shorter length of stay but had similar analgesic requirements to those undergoing open repair. Radiographic, clinical success rates and complication risk were comparable. This study had several limitations, aside from lack of randomization. Analgesic use was limited to an inpatient setting, and pain scores were not assessed. Not all children underwent a postoperative VCUG, so

  15. Individualized robot-assisted training for MS- and stroke patients in I-TRAVLE

    Directory of Open Access Journals (Sweden)

    Bastiaens Hanne

    2011-12-01

    Full Text Available Persons with central nervous deficits, such as MS and stroke patients, can benefit a lot from suitable training approaches that enhance their ability to perform activities in daily life. Personalized training, in accordance with the individual capabilities of the patient is a key issue in this context. We propose several techniques for individualization, including adaptive training games. Evaluations with patients and therapists reveal appreciation for the resulting Individualized, Technology-supported and RobotAssisted Virtual Learning Environments (I-TRAVLE system.

  16. An In-home Advanced Robotic System to Manage Elderly Home-care Patients' Medications: A Pilot Safety and Usability Study.

    Science.gov (United States)

    Rantanen, Pekka; Parkkari, Timo; Leikola, Saija; Airaksinen, Marja; Lyles, Alan

    2017-05-01

    We examined the safety profile and usability of an integrated advanced robotic device and telecare system to promote medication adherence for elderly home-care patients. There were two phases. Phase I aimed to verify under controlled conditions in a single nursing home (n = 17 patients) that no robotic malfunctions would hinder the device's safe use. Phase II involved home-care patients from 3 sites (n = 27) who were on long-term medication. On-time dispensing and missed doses were recorded by the robotic system. Patients' and nurses' experiences were assessed with structured interviews. The 17 nursing home patients had 457 total days using the device (Phase I; mean, 26.9 per patient). On-time sachet retrieval occurred with 97.7% of the alerts, and no medication doses were missed. At baseline, Phase II home-dwelling patients reported difficulty remembering to take their medicines (23%), and 18% missed at least 2 doses per week. Most Phase II patients (78%) lived alone. The device delivered and patients retrieved medicine sachets for 99% of the alerts. All patients and 96% of nurses reported the device was easy to use. This trial demonstrated the safety profile and usability of an in-home advanced robotic device and telecare system and its acceptability to patients and nurses. It supports individualized patient dosing schedules, patient-provider communications, and on-time, in-home medication delivery to promote adherence. Real time dose-by-dose monitoring and communication with providers if a dose is missed provide oversight generally not seen in home care. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Association of PTP1B with Outcomes of Breast Cancer Patients Who Underwent Neoadjuvant Chemotherapy.

    Science.gov (United States)

    Rivera Franco, Monica M; Leon Rodriguez, Eucario; Martinez Benitez, Braulio; Villanueva Rodriguez, Luisa G; de la Luz Sevilla Gonzalez, Maria; Armengol Alonso, Alejandra

    2016-01-01

    PTP1B is involved in the oncogenesis of breast cancer. In addition, neoadjuvant therapy has been widely used in breast cancer; thus, a measurement to assess survival improvement could be pathological complete response (pCR). Our objective was to associate PTP1B overexpression with outcomes of breast cancer patients who underwent neoadjuvant chemotherapy. Forty-six specimens were included. Diagnostic biopsies were immunostained using anti-PTP1B antibody. Expression was categorized as negative (<5%) and overexpression (≥5%). Patients' responses were graded according to the Miller-Payne system. Sixty-three percent of patients overexpressed PTP1B. There was no significant association between PTP1B overexpression and pCR ( P = 0.2). However, when associated with intrinsic subtypes, overexpression was higher in human epidermal growth factor receptor 2-positive-enriched specimens ( P = 0.02). Ten-year progression-free survival showed no differences. Our preliminary results do not show an association between PTP1B over-expression and pCR; however, given the limited sample and heterogeneous treatment in our cohort, this hypothesis cannot be excluded.

  18. Association of PTP1B with Outcomes of Breast Cancer Patients who Underwent Neoadjuvant Chemotherapy

    Directory of Open Access Journals (Sweden)

    Monica M. Rivera Franco

    2016-01-01

    Full Text Available PTP1B is involved in the oncogenesis of breast cancer. In addition, neoadjuvant therapy has been widely used in breast cancer; thus, a measurement to assess survival improvement could be pathological complete response (pCR. Our objective was to associate PTP1B overexpression with outcomes of breast cancer patients who underwent neoadjuvant chemotherapy. Forty-six specimens were included. Diagnostic biopsies were immunostained using anti-PTP1B antibody. Expression was categorized as negative (<5% and overexpression (≥5%. Patients' responses were graded according to the Miller-Payne system. Sixty-three percent of patients overexpressed PTP1B. There was no significant association between PTP1B overexpression and pCR (P = 0.2. However, when associated with intrinsic subtypes, overexpression was higher in human epidermal growth factor receptor 2-positive-enriched specimens (P = 0.02. Ten-year progression-free survival showed no differences. Our preliminary results do not show an association between PTP1B overexpression and pCR; however, given the limited sample and heterogeneous treatment in our cohort, this hypothesis cannot be excluded.

  19. Robot-assisted gait training in patients with Parkinson disease: a randomized controlled trial.

    Science.gov (United States)

    Picelli, Alessandro; Melotti, Camilla; Origano, Francesca; Waldner, Andreas; Fiaschi, Antonio; Santilli, Valter; Smania, Nicola

    2012-05-01

    . Gait impairment is a common cause of disability in Parkinson disease (PD). Electromechanical devices to assist stepping have been suggested as a potential intervention. . To evaluate whether a rehabilitation program of robot-assisted gait training (RAGT) is more effective than conventional physiotherapy to improve walking. . A total of 41 patients with PD were randomly assigned to 45-minute treatment sessions (12 in all), 3 days a week, for 4 consecutive weeks of either robotic stepper training (RST; n = 21) using the Gait Trainer or physiotherapy (PT; n = 20) with active joint mobilization and a modest amount of conventional gait training. Participants were evaluated before, immediately after, and 1 month after treatment. Primary outcomes were 10-m walking speed and distance walked in 6 minutes. . Baseline measures revealed no statistical differences between groups, but the PT group walked 0.12 m/s slower; 5 patients withdrew. A statistically significant improvement was found in favor of the RST group (walking speed 1.22 ± 0.19 m/s [P = .035]; distance 366.06 ± 78.54 m [P < .001]) compared with the PT group (0.98 ± 0.32 m/s; 280.11 ± 106.61 m). The RAGT mean speed increased by 0.13 m/s, which is probably not clinically important. Improvements were maintained 1 month later. . RAGT may improve aspects of walking ability in patients with PD. Future trials should compare robotic assistive training with treadmill or equal amounts of overground walking practice.

  20. Does transition from the da Vinci Si to Xi robotic platform impact single-docking technique for robot-assisted laparoscopic nephroureterectomy?

    Science.gov (United States)

    Patel, Manish N; Aboumohamed, Ahmed; Hemal, Ashok

    2015-12-01

    To describe our robot-assisted nephroureterectomy (RNU) technique for benign indications and RNU with en bloc excision of bladder cuff (BCE) and lymphadenectomy (LND) for malignant indications using the da Vinci Si and da Vinci Xi robotic platform, with its pros and cons. The port placement described for Si can be used for standard and S robotic systems. This is the first report in the literature on the use of the da Vinci Xi robotic platform for RNU. After a substantial experience of RNU using different da Vinci robots from the standard to the Si platform in a single-docking fashion for benign and malignant conditions, we started using the newly released da Vinci Xi robot since 2014. The most important differences are in port placement and effective use of the features of da Vinci Xi robot while performing simultaneous upper and lower tract surgery. Patient positioning, port placement, step-by-step technique of single docking RNU-LND-BCE using the da Vinci Si and da Vinci Xi robot are shown in an accompanying video with the goal that centres using either robotic system benefit from the hints and tips. The first segment of video describes RNU-LND-BCE using the da Vinci Si followed by the da Vinci Xi to highlight differences. There was no need for patient repositioning or robot re-docking with the new da Vinci Xi robotic platform. We have experience of using different robotic systems for single docking RNU in 70 cases for benign (15) and malignant (55) conditions. The da Vinci Xi robotic platform helps operating room personnel in its easy movement, allows easier patient side-docking with the help of its boom feature, in addition to easy and swift movements of the robotic arms. The patient clearance feature can be used to avoid collision with the robotic arms or the patient's body. In patients with challenging body habitus and in situations where bladder cuff management is difficult, modifications can be made through reassigning the camera to a different port with

  1. Robotic-assisted thermal ablation of liver tumours

    International Nuclear Information System (INIS)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong; Goh, Khean Lee; Yoong, Boon Koon; Ho, Gwo Fuang; Yim, Carolyn Chue Wai; Kulkarni, Anjali

    2015-01-01

    This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system. Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance. Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method. This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients. (orig.)

  2. Robotic-assisted thermal ablation of liver tumours

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong [University of Malaya, Department of Biomedical Imaging and University of Malaya Research Imaging Centre, Faculty of Medicine, Kuala Lumpur (Malaysia); University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Goh, Khean Lee [University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Yoong, Boon Koon [University of Malaya, Department of Surgery, Faculty of Medicine, Kuala Lumpur (Malaysia); Ho, Gwo Fuang [University of Malaya, Department of Oncology, Faculty of Medicine, Kuala Lumpur (Malaysia); Yim, Carolyn Chue Wai [University of Malaya, Department of Anesthesia, Faculty of Medicine, Kuala Lumpur (Malaysia); Kulkarni, Anjali [Perfint Healthcare Corporation, Florence, OR (United States)

    2015-01-15

    This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system. Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance. Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method. This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients. (orig.)

  3. [A survey of perioperative asthmatic attack among patients with bronchial asthma underwent general anesthesia].

    Science.gov (United States)

    Ie, Kenya; Yoshizawa, Atsuto; Hirano, Satoru; Izumi, Sinyuu; Hojo, Masaaki; Sugiyama, Haruhito; Kobayasi, Nobuyuki; Kudou, Kouichirou; Maehara, Yasuhiro; Kawachi, Masaharu; Miyakoshi, Kouichi

    2010-07-01

    We investigated the risk factor of perioperative asthmatic attack and effectiveness of preventing treatment for asthmatic attack before operation. We performed retrospective chart review of one hundred eleven patients with asthma underwent general anesthesia and surgical intervention from January 2006 to October 2007 in our hospital. The rate of perioperative asthmatic attack were as follows; 10.2% (5 in 49 cases) in no pretreatment group, 7.5% (3 in 40 cases) in any pretreatments except for systemic steroid, and 4.5% (1 in 22 cases) in systemic steroid pretreatment group. Neither preoperative asthma severity nor duration from the last attack had significant relevancy to perioperative attack rate. The otolaryngological surgery, especially those have nasal polyp and oral surgery had high perioperative asthma attack rate, although there was no significant difference. We recommend the systemic steroid pretreatment for asthmatic patients, especially when they have known risk factor such as administration of the systemic steroid within 6 months, or possibly new risk factor such as nasal polyp, otolaryngological and oral surgery.

  4. Considerations for designing robotic upper limb rehabilitation devices

    Science.gov (United States)

    Nadas, I.; Vaida, C.; Gherman, B.; Pisla, D.; Carbone, G.

    2017-12-01

    The present study highlights the advantages of robotic systems for post-stroke rehabilitation of the upper limb. The latest demographic studies illustrate a continuous increase of the average life span, which leads to a continuous increase of stroke incidents and patients requiring rehabilitation. Some studies estimate that by 2030 the number of physical therapists will be insufficient for the patients requiring physical rehabilitation, imposing a shift in the current methodologies. A viable option is the implementation of robotic systems that assist the patient in performing rehabilitation exercises, the physical therapist role being to establish the therapeutic program for each patient and monitor their individual progress. Using a set of clinical measurements for the upper limb motions, the analysis of rehabilitation robotic systems provides a comparative study between the motions required by clinicians and the ones that robotic systems perform for different therapeutic exercises. A critical analysis of existing robots is performed using several classifications: mechanical design, assistance type, actuation and power transmission, control systems and human robot interaction (HRI) strategies. This classification will determine a set of pre-requirements for the definition of new concepts and efficient solutions for robotic assisted rehabilitation therapy.

  5. Estimation of absorbed dose of radiosensitive organs and effective sose in patients underwent abdominopelvic spiral CT scan using impact CT patient dosimetry

    Directory of Open Access Journals (Sweden)

    Ayoub Amirnia

    2017-05-01

    Full Text Available Background: Due to the presence of radiosensitive organs in the abdominopelvic region and increasing the number of requests for CT scan examinations, concerns about increasing radiation doses in patients has been greatly elevated. Therefore, the goal of this study was to determine the absorbed dose of radiosensitive organs and the effective dose in patients underwent abdominopelvic CT scan using ImPACT CT patient dosimetry Calculator (version 1.0.4, Imaging Performance Assessment on Computed Tomography, www.impactscan.org. Methods: This prospective cross-sectional study was conducted in Imam Reza Hospital from November to February 2015 February 2015 in the Imam Reza Hospital, in Urmia, Iran. The demographic and dosimetric information of 100 patients who underwent abdominopelvic CT scan in a 6-slice CT scanner were obtained through the data collection forms. The demographic data of the patients included age, weight, gender, and BMI. The dosimetric parameters included pitch value, CT dose volume index (CTDIvol, dose-length product (DLP, tube voltage, tube current, exposure time, collimation size, scan length, and scan time. To determine the absorbed dose of radiosensitive organs and also the effective dose in patients, ImPACT CT patient dosimetry calculator was used. Results: The results of this study demonstrated that the mean and standard deviation (SD of patients' effective dose in abdominopelvic CT scan was 4.927±0.164 mSv. The bladder in both genders had the greatest mean organ dose, which was 64.71±17.15 mGy for men and 77.56±18.48 mGy for women (P<0.001. Conclusion: The effective dose values of this examination are in the same range as previous studies, as well as International Commission on Radiological Protection (ICRP recommendations. However, the radiation dose from CT scan has the largest contribution to the medical imaging. According to the ALARA principle, it is recommended that the scan parameters, especially mAs, should be

  6. Ontogeny of a surgical technique: Robotic kidney transplantation with regional hypothermia.

    Science.gov (United States)

    Sood, Akshay; McCulloch, Peter; Dahm, Philipp; Ahlawat, Rajesh; Jeong, Wooju; Bhandari, Mahendra; Menon, Mani

    2016-01-01

    Innovation is a hallmark of surgical practice. It is generally accepted that a new procedure will undergo technical changes during its evolution; however, quantitative accounts of the process are limited. Multiple groups, including our own, have recently described a minimally-invasive approach to conventional kidney transplantation (KT) operation. Unique to our experience is a structured development of the technique within the confines of a safe surgical innovation framework - the IDEAL framework (idea, development, exploration, assessment, long-term monitoring; stages 0-4). We here provide a first-hand narrative of the progress of robotic KT operation from preclinical trial to clinical application. Overall, 54 patients underwent robotic KT with regional hypothermia successfully. Major technical changes including selection of optimal patient position (flank vs. lithotomy), robotic instrumentation, vascular occlusion method (bulldog vs. tourniquet) and suture material (prolene vs. GoreTex) occurred early during the procedure development (IDEAL stage 0, preclinical). Minor technical changes such as utilization of the aortic punch for arteriotomy (case 3), use of barbed suture during ureteroneocystostomy (case 6) and extraperitonealization of the graft kidney (case 6) that increased the efficiency and safety of the procedure continued throughout procedure development (IDEAL stages 1-2, clinical stages). We demonstrate that a surgical technique evolves continually; although, the majority of technical alterations occur early in the life-cycle of the procedure. Development of a new technique within the confines a structured surgical innovation framework allows for evidence based progression of the technique and may minimize the risk of harm to the patient. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  7. [Human-robot global Simulink modeling and analysis for an end-effector upper limb rehabilitation robot].

    Science.gov (United States)

    Liu, Yali; Ji, Linhong

    2018-02-01

    Robot rehabilitation has been a primary therapy method for the urgent rehabilitation demands of paralyzed patients after a stroke. The parameters in rehabilitation training such as the range of the training, which should be adjustable according to each participant's functional ability, are the key factors influencing the effectiveness of rehabilitation therapy. Therapists design rehabilitation projects based on the semiquantitative functional assessment scales and their experience. But these therapies based on therapists' experience cannot be implemented in robot rehabilitation therapy. This paper modeled the global human-robot by Simulink in order to analyze the relationship between the parameters in robot rehabilitation therapy and the patients' movement functional abilities. We compared the shoulder and elbow angles calculated by simulation with the angles recorded by motion capture system while the healthy subjects completed the simulated action. Results showed there was a remarkable correlation between the simulation data and the experiment data, which verified the validity of the human-robot global Simulink model. Besides, the relationship between the circle radius in the drawing tasks in robot rehabilitation training and the active movement degrees of shoulder as well as elbow was also matched by a linear, which also had a remarkable fitting coefficient. The matched linear can be a quantitative reference for the robot rehabilitation training parameters.

  8. Initial experience of robotic versus laparoscopic colectomy for transverse colon cancer: a matched case-control study.

    Science.gov (United States)

    de'Angelis, Nicola; Alghamdi, Salah; Renda, Andrea; Azoulay, Daniel; Brunetti, Francesco

    2015-10-09

    Robotic surgery for transverse colon cancer has rarely been described. This study reports our initial experience in robotic resection for transverse colon cancer, by comparing robotic transverse colectomy (RC) to laparoscopic transverse colectomy (LC) in terms of safety, feasibility, short-term outcomes, and the surgeon's psychological stress and physical pain. The study population included the first 22 consecutive patients who underwent RC between March 2013 and December 2014 for histologically confirmed transverse colon adenocarcinoma. These patients were compared with 22 matched patients undergoing LC between December 2010 and February 2013. Patients were matched based on age, gender, body mass index (BMI), American Society of Anesthesiology (ASA) score, American Joint Committee on Cancer (AJCC) tumor stage, and tumor location (ratio 1:1). Mortality, morbidity, operative, and short-term oncologic outcomes were compared between groups. The operating surgeon's stress and pain were assessed before and after surgery on a 0-100-mm visual analog scale. The demographic and preoperative characteristics were comparable between RC and LC patients. No group difference was observed for intraoperative complications, blood loss, postoperative pain, time to flatus, time to regular diet, and hospital stay. RC was associated with longer operative time than LC (260 min vs. 225 min; p = 0.014), but the overall operative and robotic time in the RC group decreased over time reflecting the increasing experience in performing this procedure. No conversion to laparotomy was observed in the RC group, while two LC patients were converted due to uncontrolled bleeding and technically difficult middle colic pedicle dissection. Postoperative complications (Dindo-Clavien grade I or II) occurred in 11.3 % of patients with no group difference. Mortality was nil. All resections were R0, with >12 lymph nodes harvested in 90.9 % of RC and 95.5 % of LC patients. The surgeon's stress was

  9. Effect of preinfarction angina pectoris on long-term survival in patients with ST-segment elevation myocardial infarction who underwent primary percutaneous coronary intervention.

    Science.gov (United States)

    Taniguchi, Tomohiko; Shiomi, Hiroki; Toyota, Toshiaki; Morimoto, Takeshi; Akao, Masaharu; Nakatsuma, Kenji; Ono, Koh; Makiyama, Takeru; Shizuta, Satoshi; Furukawa, Yutaka; Nakagawa, Yoshihisa; Ando, Kenji; Kadota, Kazushige; Horie, Minoru; Kimura, Takeshi

    2014-10-15

    The influence of preinfarction angina pectoris (AP) on long-term clinical outcomes in patients with ST-segment elevation myocardial infarction (STEMI) who underwent primary percutaneous coronary intervention (PCI) remains controversial. In 5,429 patients with acute myocardial infarction (AMI) enrolled in the Coronary Revascularization Demonstrating Outcome Study in Kyoto AMI Registry, the present study population consisted of 3,476 patients with STEMI who underwent primary PCI within 24 hours of symptom onset and in whom the data on preinfarction AP were available. Preinfarction AP defined as AP occurring within 48 hours of hospital arrival was present in 675 patients (19.4%). Patients with preinfarction AP was younger and more often had anterior AMI and longer total ischemic time, whereas they less often had history of heart failure, atrial fibrillation, and shock presentation. The infarct size estimated by peak creatinine phosphokinase was significantly smaller in patients with than in patients without preinfarction AP (median [interquartile range] 2,141 [965 to 3,867] IU/L vs 2,462 [1,257 to 4,495] IU/L, p <0.001). The cumulative 5-year incidence of death was significantly lower in patients with preinfarction AP (12.4% vs 20.7%, p <0.001) with median follow-up interval of 1,845 days. After adjusting for confounders, preinfarction AP was independently associated with a lower risk for death (hazard ratio 0.69, 95% confidence interval 0.54 to 0.86, p = 0.001). The lower risk for 5-year mortality in patients with preinfarction AP was consistently observed across subgroups stratified by total ischemic time, initial Thrombolysis In Myocardial Infarction flow grade, hemodynamic status, infarct location, and diabetes mellitus. In conclusion, preinfarction AP was independently associated with lower 5-year mortality in patients with STEMI who underwent primary PCI. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Robotic and endoscopic transaxillary thyroidectomies may be cost prohibitive when compared to standard cervical thyroidectomy: a cost analysis.

    Science.gov (United States)

    Cabot, Jennifer C; Lee, Cho Rok; Brunaud, Laurent; Kleiman, David A; Chung, Woong Youn; Fahey, Thomas J; Zarnegar, Rasa

    2012-12-01

    This study presents a cost analysis of the standard cervical, gasless transaxillary endoscopic, and gasless transaxillary robotic thyroidectomy approaches based on medical costs in the United States. A retrospective review of 140 patients who underwent standard cervical, transaxillary endoscopic, or transaxillary robotic thyroidectomy at 2 tertiary centers was conducted. The cost model included operating room charges, anesthesia fee, consumables cost, equipment depreciation, and maintenance cost. Sensitivity analyses assessed individual cost variables. The mean operative times for the standard cervical, transaxillary endoscopic, and transaxillary robotic approaches were 121 ± 18.9, 185 ± 26.0, and 166 ± 29.4 minutes, respectively. The total cost for the standard cervical, transaxillary endoscopic, and transaxillary robotic approaches were $9,028 ± $891, $12,505 ± $1,222, and $13,670 ± $1,384, respectively. Transaxillary approaches were significantly more expensive than the standard cervical technique (standard cervical/transaxillary endoscopic, P cost when transaxillary endoscopic operative time decreased to 111 minutes and transaxillary robotic operative time decreased to 68 minutes. Increasing the case load did not resolve the cost difference. Transaxillary endoscopic and transaxillary robotic thyroidectomies are significantly more expensive than the standard cervical approach. Decreasing operative times reduces this cost difference. The greater expense may be prohibitive in countries with a flat reimbursement schedule. Copyright © 2012 Mosby, Inc. All rights reserved.

  11. Robot-Assisted Body-Weight-Supported Treadmill Training in Gait Impairment in Multiple Sclerosis Patients: A Pilot Study.

    Science.gov (United States)

    Łyp, Marek; Stanisławska, Iwona; Witek, Bożena; Olszewska-Żaczek, Ewelina; Czarny-Działak, Małgorzata; Kaczor, Ryszard

    2018-02-13

    This study deals with the use of a robot-assisted body-weight-supported treadmill training in multiple sclerosis (MS) patients with gait dysfunction. Twenty MS patients (10 men and 10 women) of the mean of 46.3 ± 8.5 years were assigned to a six-week-long training period with the use of robot-assisted treadmill training of increasing intensity of the Lokomat type. The outcome measure consisted of the difference in motion-dependent torque of lower extremity joint muscles after training compared with baseline before training. We found that the training uniformly and significantly augmented the torque of both extensors and flexors of the hip and knee joints. The muscle power in the lower limbs of SM patients was improved, leading to corrective changes of disordered walking movements, which enabled the patients to walk with less effort and less assistance of care givers. The torque augmentation could have its role in affecting the function of the lower extremity muscle groups during walking. The results of this pilot study suggest that the robot-assisted body-weight-supported treadmill training may be a potential adjunct measure in the rehabilitation paradigm of 'gait reeducation' in peripheral neuropathies.

  12. Robot-assisted general surgery.

    Science.gov (United States)

    Hazey, Jeffrey W; Melvin, W Scott

    2004-06-01

    With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.

  13. Liability exposure for surgical robotics instructors.

    Science.gov (United States)

    Lee, Yu L; Kilic, Gokhan; Phelps, John Y

    2012-01-01

    Surgical robotics instructors provide an essential service in improving the competency of novice gynecologic surgeons learning robotic surgery and advancing surgical skills on behalf of patients. However, despite best intentions, robotics instructors and the gynecologists who use their services expose themselves to liability. The fear of litigation in the event of a surgical complication may reduce the availability and utility of robotics instructors. A better understanding of the principles of duty of care and the physician-patient relationship, and their potential applicability in a court of law likely will help to dismantle some concerns and uncertainties about liability. This commentary is not meant to discourage current and future surgical instructors but to raise awareness of liability issues among robotics instructors and their students and to recommend certain preventive measures to curb potential liability risks. Published by Elsevier Inc.

  14. Social robots in advanced dementia

    Directory of Open Access Journals (Sweden)

    Meritxell eValentí Soler

    2015-09-01

    Full Text Available Aims: Testing the effect of the experimental robot-based therapeutic sessions for patients with dementia in: a controlled study of parallel groups of nursing home patients comparing the effects of therapy sessions utilizing a humanoid robot (NAO, an animal-shaped robot (PARO, or a trained dog (DOG, with conventional therapy (CONTROL on symptoms of dementia; and an experience for patients who attend a day care center, comparing symptom prevalence and severity before and after sessions utilizing NAO and PARO. Methods: In the nursing home, patients were randomly assigned by blocks, based on dementia severity, to one of the 3 therapeutic groups to compare: CONTROL, PARO and NAO (phase 1 and CONTROL, PARO and DOG (phase 2. In the day care center, all patients received therapy with NAO (phase 1 and PARO (phase 2. Therapy sessions were held 2 days/week for 3 months. Evaluation at baseline and follow-up was carried out by blind raters using: the Global Deterioration Scale (GDS, the Severe Mini Mental State Examination (sMMSE, the Mini Mental State Examination (MMSE, the Neuropsychiatric Inventory (NPI, the Apathy Scale for Institutionalized Patients with Dementia Nursing Home version (APADEM-NH, the Apathy Inventory (AI and the Quality of Life Scale (QUALID. Statistical analysis included descriptive statistics and non parametric tests performed by a blinded investigator. Results: In the nursing home, 101 patients (phase 1 and 110 patients (phase 2 were included. There were no significant differences at baseline. The relevant changes at follow-up were: (phase 1 patients in the robot groups showed an improvement in apathy; patients in NAO group showed a decline in cognition as measured by the MMSE scores, but not the sMMSE; the robot groups showed no significant changes between them; (phase 2 QUALID scores increased in the PARO group. In the day care center, 20 patients (phase 1 and 17 patients (phase 2 were included. The main findings were: (phase 1 imp

  15. What does best evidence tell us about robotic gait rehabilitation in stroke patients: A systematic review and meta-analysis.

    Science.gov (United States)

    Bruni, Maria Federica; Melegari, Corrado; De Cola, Maria Cristina; Bramanti, Alessia; Bramanti, Placido; Calabrò, Rocco Salvatore

    2018-02-01

    Studies about electromechanical-assisted devices proved the validity and effectiveness of these tools in gait rehabilitation, especially if used in association with conventional physiotherapy in stroke patients. The aim of this study was to compare the effects of different robotic devices in improving post-stroke gait abnormalities. A computerized literature research of articles was conducted in the databases MEDLINE, PEDro, COCHRANE, besides a search for the same items in the Library System of the University of Parma (Italy). We selected 13 randomized controlled trials, and the results were divided into sub-acute stroke patients and chronic stroke patients. We selected studies including at least one of the following test: 10-Meter Walking Test, 6-Minute Walk Test, Timed-Up-and-Go, 5-Meter Walk Test, and Functional Ambulation Categories. Stroke patients who received physiotherapy treatment in combination with robotic devices, such as Lokomat or Gait Trainer, were more likely to reach better results, compared to patients who receive conventional gait training alone. Moreover, electromechanical-assisted gait training in association with Functional Electrical Stimulations produced more benefits than the only robotic treatment (-0.80 [-1.14; -0.46], p > .05). The evaluation of the results confirm that the use of robotics can positively affect the outcome of a gait rehabilitation in patients with stroke. The effects of different devices seems to be similar on the most commonly outcome evaluated by this review. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The Use of Industrial Robot Arms for High Precision Patient Positioning

    International Nuclear Information System (INIS)

    Katuin, J.E.; Schreuder, A.N.; Starks, W.M.; Doskow, J.

    2003-01-01

    The Indiana University Cyclotron Facility (IUCF) is in the process of designing and building the Midwest Proton Radiation Institute (MPRI) [1]. The design process includes the development of several patient treatment systems. This paper discusses the use of two such systems that provide for the high precision positioning of a patient. They are the Patient Positioner System and the X-ray system. The Patient Positioner System positions an immobilized patient on a support device to a treatment position based on a prescribed Treatment Plan. The X-ray system uses an industrial robot arm to position a Digital Radiography Panel to acquire an X-ray image to verify the location of the prescribed treatment volume in a patient by comparing the acquired images with reference images obtained from the patient's Treatment plan

  17. The current status of robotic transaxillary thyroidectomy in the United States: an experience from two centers.

    Science.gov (United States)

    Zaidi, Nisar; Daskalaki, Despoina; Quadri, Pablo; Okoh, Alexis; Giulianotti, Pier Cristoforo; Berber, Eren

    2017-08-01

    Few studies exist regarding the state of robotic transaxillary thyroidectomy (RT) and its outcomes at high-volume institutions. Eighty-nine patients underwent RT between January 2009 and September 2015 at two tertiary centers. Data were collected from prospectively-maintained IRB-approved databases. Patient demographic and clinical data, and trends were evaluated. Indications for RT included biopsy-proven or suspicion for malignancy in 20.2%, atypical cells or follicular neoplasm in 27.7%, multinodular goiter in 26.6%, thyrotoxicosis in 8.5%, need for completion thyroidectomy in 5.3%, and non-diagnostic FNA in 3.2%. 56% underwent total thyroidectomy and 44% lobectomy. Operative time (OT) was 153.5 minutes for lobectomies and 192.6 minutes for total thyroidectomy. The complication rate was 11.7%: temporary RLN neuropraxia in 2 patients, permanent hypoparathyroidism in 1 patient, temporary hypoparathyroidism in 6 patients, flap seroma in 1 patient, and flap hematoma in 1 patient. Pathology showed malignancy in 43 patients. At a mean follow-up of 31.9 months, there were no recurrences. Since 2013, the number of RTs performed has risen. The number of out-of-state patients increased from 18% to 37% after 2011. RT was performed without compromising outcomes in selected patients. There remains interest among patients seeking this procedure in expert centers.

  18. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    Science.gov (United States)

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Robots and the Limits of Morality

    DEFF Research Database (Denmark)

    Rodogno, Raffaele

    2016-01-01

    In this chapter, I ask whether we can coherently conceive of robots as moral agents and as moral patients. I answer both questions negatively but conditionally: for as long as robots lack certain features, they can be neither moral agents nor moral patients. These answers, of course, are not new...... and biological bases of moral practices and arguing that the relevant differences in such bases are sufficient, for the time being, to exclude robots from adopting, both, an active and a passive moral role....

  20. Robotic pancreas drainage procedure for chronic pancreatitis: robotic lateral pancreaticojejunostomy (Puestow procedure).

    Science.gov (United States)

    Khan, Adeel S; Siddiqui, Imran; Vrochides, Dionisios; Martinie, John B

    2018-01-01

    Lateral pancreaticojejunostomy (LPJ), also known as the Puestow procedure, is a complex surgical procedure reserved for patients with refractory chronic pancreatitis (CP) and a dilated pancreatic duct. Traditionally, this operation is performed through an open incision, however, recent advancements in minimally invasive techniques have made it possible to perform the surgery using laparoscopic and robotic techniques with comparable safety. Though we do not have enough data yet to prove superiority of one over the other, the robotic approach appears to have an advantage over the laparoscopic technique in better visualization through 3-dimensional (3D) imaging and availability of wristed instruments for more precise actions, which may translate into superior outcomes. This paper is a description of our technique for robotic LPJ in patients with refractory CP. Important principles of patient selection, preoperative workup, surgical technique and post-operative management are discussed. A short video with a case presentation and highlights of the important steps of the surgery is included.

  1. A New Risk Factor Profile for Contrast-Induced Acute Kidney Injury in Patients Who Underwent an Emergency Percutaneous Coronary Intervention.

    Science.gov (United States)

    Yuan, Ying; Qiu, Hong; Song, Lei; Hu, Xiaoying; Luo, Tong; Zhao, Xueyan; Zhang, Jun; Wu, Yuan; Qiao, Shubin; Yang, Yuejin; Gao, Runlin

    2018-07-01

    We developed a new risk factor profile for contrast-induced acute kidney injury (CI-AKI) under a new definition in patients who underwent an emergency percutaneous coronary intervention (PCI). Consecutive patients (n = 1061) who underwent an emergency PCI were divided into a derivation group (n = 761) and a validation group (n = 300). The rates of CI-AKI were 23.5% (definition 1: serum creatinine [SCr] increase ≥25% in 72 hours), 4.3% (definition 2: SCr increase ≥44.2 μmol/L in 72 hours), and 7.0% (definition 3: SCr increase ≥44.2 μmol/L in 7 days). Due to the high sensitivity of definition 1 and the high rate of missed cases for late diagnosis of CI-AKI under definition 2, definition 3 was used in the study. The risk factor profile included body surface area 15.00 × 10 9 /L ( P = .047), estimated glomerular filtration rate 133 μmol/L ( P = .007), intra-aortic balloon pump application ( P = .006), and diuretics administration ( P risk factor profile of CI-AKI under a new CI-AKI definition in emergency PCI patients is easily applicable with a useful predictive value.

  2. Effect of visual distraction and auditory feedback on patient effort during robot-assisted movement training after stroke

    Directory of Open Access Journals (Sweden)

    Reinkensmeyer David J

    2011-04-01

    Full Text Available Abstract Background Practicing arm and gait movements with robotic assistance after neurologic injury can help patients improve their movement ability, but patients sometimes reduce their effort during training in response to the assistance. Reduced effort has been hypothesized to diminish clinical outcomes of robotic training. To better understand patient slacking, we studied the role of visual distraction and auditory feedback in modulating patient effort during a common robot-assisted tracking task. Methods Fourteen participants with chronic left hemiparesis from stroke, five control participants with chronic right hemiparesis and fourteen non-impaired healthy control participants, tracked a visual target with their arms while receiving adaptive assistance from a robotic arm exoskeleton. We compared four practice conditions: the baseline tracking task alone; tracking while also performing a visual distracter task; tracking with the visual distracter and sound feedback; and tracking with sound feedback. For the distracter task, symbols were randomly displayed in the corners of the computer screen, and the participants were instructed to click a mouse button when a target symbol appeared. The sound feedback consisted of a repeating beep, with the frequency of repetition made to increase with increasing tracking error. Results Participants with stroke halved their effort and doubled their tracking error when performing the visual distracter task with their left hemiparetic arm. With sound feedback, however, these participants increased their effort and decreased their tracking error close to their baseline levels, while also performing the distracter task successfully. These effects were significantly smaller for the participants who used their non-paretic arm and for the participants without stroke. Conclusions Visual distraction decreased participants effort during a standard robot-assisted movement training task. This effect was greater for

  3. Systematic review of robotic surgery in gynecology: robotic techniques compared with laparoscopy and laparotomy.

    Science.gov (United States)

    Gala, Rajiv B; Margulies, Rebecca; Steinberg, Adam; Murphy, Miles; Lukban, James; Jeppson, Peter; Aschkenazi, Sarit; Olivera, Cedric; South, Mary; Lowenstein, Lior; Schaffer, Joseph; Balk, Ethan M; Sung, Vivian

    2014-01-01

    The Society of Gynecologic Surgeons Systematic Review Group performed a systematic review of both randomized and observational studies to compare robotic vs nonrobotic surgical approaches (laparoscopic, abdominal, and vaginal) for treatment of both benign and malignant gynecologic indications to compare surgical and patient-centered outcomes, costs, and adverse events associated with the various surgical approaches. MEDLINE and the Cochrane Central Register of Controlled Trials were searched from inception to May 15, 2012, for English-language studies with terms related to robotic surgery and gynecology. Studies of any design that included at least 30 women who had undergone robotic-assisted laparoscopic gynecologic surgery were included for review. The literature yielded 1213 citations, of which 97 full-text articles were reviewed. Forty-four studies (30 comparative and 14 noncomparative) met eligibility criteria. Study data were extracted into structured electronic forms and reconciled by a second, independent reviewer. Our analysis revealed that, compared with open surgery, robotic surgery consistently confers shorter hospital stay. The proficiency plateau seems to be lower for robotic surgery than for conventional laparoscopy. Of the various gynecologic applications, there seems to be evidence that renders robotic techniques advantageous over traditional open surgery for management of endometrial cancer. However, insofar as superiority, conflicting data are obtained when comparing robotics vs laparoscopic techniques. Therefore, the specific method of minimally invasive surgery, whether conventional laparoscopy or robotic surgery, should be tailored to patient selection, surgeon ability, and equipment availability. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  4. Robot-assisted surgery: the future is here.

    Science.gov (United States)

    Gerhardus, Diana

    2003-01-01

    According to L. Wiley Nifong, director of robotic surgery at East Carolina University's Brody School of Medicine, "Nationally, only one-fourth of the 15 million surgeries performed each year are done with small incisions or what doctors call 'minimally invasive surgery'." Robots could raise that number substantially (Stark 2002). Currently, healthcare organizations use robot technology for thoracic, abdominal, pelvic, and neurological surgical procedures. Minimally invasive surgery reduces the amount of inpatient hospital days, and the computer in the system filters any hand tremors a physician may have during the surgery. The use of robot-assisted surgery improves quality of care because the patient experiences less pain after the surgery. Robot-assisted surgery demonstrates definite advantages for the patient, physician, and hospital; however, healthcare organizations in the United States have yet to acquire the technology because of implementation costs and the lack of FDA (Food and Drug Administration) approval for using the technology for certain types of heart procedures. This article focuses on robot-assisted surgery advantages to patients, physicians, and hospitals as well as on the disadvantages to physicians. In addition, the article addresses implementation costs, which creates financial hurdles for most healthcare organizations; offers recommendations for administrators to embrace this technology for strategic positioning; and enumerates possible roles for robots in medicine.

  5. Salvage robotic radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Samuel D Kaffenberger

    2014-01-01

    Full Text Available Failure of non-surgical primary treatment for localized prostate cancer is a common occurrence, with rates of disease recurrence ranging from 20% to 60%. In a large proportion of patients, disease recurrence is clinically localized and therefore potentially curable. Unfortunately, due to the complex and potentially morbid nature of salvage treatment, radical salvage surgery is uncommonly performed. In an attempt to decrease the morbidity of salvage therapy without sacrificing oncologic efficacy, a number of experienced centers have utilized robotic assistance to perform minimally invasive salvage radical prostatectomy. Herein, we critically evaluate the existing literature on salvage robotic radical prostatectomy with a focus on patient selection, perioperative complications and functional and early oncologic outcomes. These results are compared with contemporary and historical open salvage radical prostatectomy series and supplemented with insights we have gained from our experience with salvage robotic radical prostatectomy. The body of evidence by which conclusions regarding the efficacy and safety of robotic salvage radical prostatectomy can be drawn comprises fewer than 200 patients with limited follow-up. Preliminary results are promising and some outcomes have been favorable when compared with contemporary open salvage prostatectomy series. Advantages of the robotic platform in the performance of salvage radical prostatectomy include decreased blood loss, short length of stay and improved visualization. Greater experience is required to confirm the long-term oncologic efficacy and functional outcomes as well as the generalizability of results achieved at experienced centers.

  6. Robotic systems in spine surgery.

    Science.gov (United States)

    Onen, Mehmet Resid; Naderi, Sait

    2014-01-01

    Surgical robotic systems have been available for almost twenty years. The first surgical robotic systems were designed as supportive systems for laparoscopic approaches in general surgery (the first procedure was a cholecystectomy in 1987). The da Vinci Robotic System is the most common system used for robotic surgery today. This system is widely used in urology, gynecology and other surgical disciplines, and recently there have been initial reports of its use in spine surgery, for transoral access and anterior approaches for lumbar inter-body fusion interventions. SpineAssist, which is widely used in spine surgery, and Renaissance Robotic Systems, which are considered the next generation of robotic systems, are now FDA approved. These robotic systems are designed for use as guidance systems in spine instrumentation, cement augmentations and biopsies. The aim is to increase surgical accuracy while reducing the intra-operative exposure to harmful radiation to the patient and operating team personnel during the intervention. We offer a review of the published literature related to the use of robotic systems in spine surgery and provide information on using robotic systems.

  7. A pilot study of robotic-assisted exercise for hand weakness after stroke.

    Science.gov (United States)

    Stein, Joel; Bishop, Joel; Gillen, Glen; Helbok, Raimund

    2011-01-01

    Upper limb paresis is a major source of disability in stroke survivors, and robotic aided exercise therapy is a promising approach to enhance motor abilities. Few devices have been available to provide robotic therapy to the fingers and hand. We report an open-label pilot study of 12 individuals with chronic moderate hemiparesis after stroke who underwent a six-week training program using a hand robotic device. Participants received a total of 18 hours of robotic therapy. Improvements were found in multiple measures of motor performance, including the Upper Extremity Fugl-Meyer, the Motor Activity Log, the Manual Ability Measure-36, and the Jebsen Hand Function Test. All subjects tolerated the treatment well and no complications were observed. We conclude that robotic therapy for hand paresis after stroke is safe and feasible, and that further studies of efficacy are justified by these preliminary results. © 2011 IEEE

  8. Prognostic significance of nuclear factor of activated T-cells 5 expression in non-small cell lung cancer patients who underwent surgical resection.

    Science.gov (United States)

    Cho, Hyun Jin; Yun, Hwan-Jung; Yang, Hee Chul; Kim, Soo Jin; Kang, Shin Kwang; Che, Chengri; Lee, Sang Do; Kang, Min-Woong

    2018-06-01

    Nuclear factor of activated T-cells 5 (NFAT5) is known to be correlated with migration or invasion of tumor cells based on previous in vitro studies. The aim of this study was to analyze the relationship between NFAT5 expression and clinical prognosis in non-small cell lung cancer (NSCLC) patients who underwent surgical resection. A total of 92 NSCLC patients who underwent surgical resection were enrolled. The tissue microarray core was obtained from surgically resected tumor specimens. NFAT5 expression was evaluated by immunohistochemistry. Relationships of NFAT5 expression with disease recurrence, overall survival, and disease-free survival (DFS) were analyzed. The mean age of 92 patients was 63.7 y. The median follow-up duration was 63.3 mo. Fifty-one (55%) patients exhibited positive expression of NFAT5. Disease recurrence in the NFAT5-positive group was significantly (P = 0.022) higher than that in the NFAT5-negative group. NFAT5-positive expression (odds ratio: 2.632, 95% confidence interval: 1.071-6.465, P = 0.035) and pathologic N stage (N1-2 versus N0; odds ratio: 3.174, 95% confidence interval: 1.241-8.123, P = 0.016) were independent and significant risk factors for disease recurrence. DFS of the NFAT5-positive group was significantly worse than that of the NFAT5-negative group (89.7 versus 48.7 mo, P = 0.011). A multivariate analysis identified NFAT5 expression (P < 0.029) as a significant independent risk factor for DFS of patients with postoperative pathologic T and N stages (P < 0.001 and P = 0.017, respectively). NFAT5 expression is a useful prognostic biomarker for NSCLC patients who underwent surgical resection. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Laws on Robots, Laws by Robots, Laws in Robots : Regulating Robot Behaviour by Design

    NARCIS (Netherlands)

    Leenes, R.E.; Lucivero, F.

    2015-01-01

    Speculation about robot morality is almost as old as the concept of a robot itself. Asimov’s three laws of robotics provide an early and well-discussed example of moral rules robots should observe. Despite the widespread influence of the three laws of robotics and their role in shaping visions of

  10. Comparison of postural ergonomics between laparoscopic and robotic sacrocolpopexy: a pilot study.

    Science.gov (United States)

    Tarr, Megan E; Brancato, Sam J; Cunkelman, Jacqueline A; Polcari, Anthony; Nutter, Benjamin; Kenton, Kimberly

    2015-02-01

    To compare resident, fellow, and attending urologic and gynecologic surgeons' musculoskeletal and mental strain during laparoscopic and robotic sacrocolpopexy. Prospective cohort study (Canadian Task Force classification II-2). Academic medical center. Patients who underwent robotic or laparoscopic sacrocolpopexy from October 2009 to January 2011. The Body Part Discomfort (BPD) survey was completed before cases, and the National Aeronautics and Space Administration Task Load Index and BPD survey were completed after cases. Higher scores on BPD and the National Aeronautics and Space Administration Task Load Index indicate greater musculoskeletal discomfort and mental strain. BPD scores were averaged over the following body regions: head/neck, back, hand/wrist, arms, and knees/ankles/feet. Changes in body region-specific discomfort scores were the primary outcomes. Multivariable analysis was performed using mixed-effects linear regression with surgeon as a random effect. Sixteen surgeons participated (53% fellows, 34% residents, and 13% attendings). Thirty-three robotic and 53 laparoscopic cases were analyzed, with a median surgical time of 231 minutes (interquartile range, 204-293 minutes) versus 227 minutes (interquartile range, 203-272 minutes; p = .31), a median estimated blood loss of 100 mL (interquartile range, 50-175 mL) versus 150 mL (interquartile range, 50-200 mL; p = .22), and a mean patient body mass index of 27 ± 4 versus 26 ± 4 kg/m(2) (p = .26), respectively. Robotic surgeries were associated with lower neck/shoulder (-0.19 [interquartile range, -0.32 to -0.01], T = -2.49) and back discomfort scores (-0.35 [interquartile range, -0.58 to 0], T = -2.38) than laparoscopic surgeries. Knee/ankle/foot and arm discomfort increased with case length (0.18 [interquartile range, 0.02-0.3], T = 2.81) and (0.07 [interquartile range, 0.01-0.14], p = .03), respectively. Surgeons performing minimally invasive sacrocolpopexy experienced less neck, shoulder, and

  11. A controlled clinical study of serosa-invasive gastric carcinoma patients who underwent surgery plus intraperitoneal hyperthermo-chemo-perfusion (IHCP).

    Science.gov (United States)

    Kim, J Y; Bae, H S

    2001-01-01

    Despite recent advances in the treatment of advanced gastric carcinomas, no satisfactory outcomes are available because of micrometastases and free-floating carcinoma cells already existing in the peritoneal cavity. From 1990, we started using intraperitoneal hyperthermo-chemo-perfusion (IHCP) to prevent and to treat peritoneal metastasis after surgical resection of stomach cancer. We analyzed 103 serosa-invasive gastric carcinoma patients who underwent surgical resection between 1990 and 1995. Fifty-two patients who received surgery plus IHCP were compared with 51 patients who underwent surgery only, as controls. IHCP was administered for 2 h with an automatic IHCP device (closed-circuit system) just after surgical resection, with the patient under hypothermic general anesthesia (32.4 degrees C-34.0 degrees C). As perfusate, we used 1.5% peritoneal dialysis solution mixed with 10 micrograms/ml of mitomycin-C (MMC), warmed at an inflow temperature of over 44 degrees C. The overall 5-year survival rate (5-YSR) of the 103 patients was 29.97%. The 5-YSR was higher in the IHCP group than in the control group, at 32.7% and 27.1%, respectively, but this difference was not significant. However, in the 65 serosa-invasive gastric carcinoma patients (excluding those in stage IV) the 5-YSR was significantly higher (P = 0.0379) in the IHCP group than in the control group, at 58.6% and 44.4%, respectively. On multivariate analysis of all 103 patients, depth of tumor invasion and lymph node metastasis were significant factors for survival, whereas significant factors on univariate analysis, such as combined operation, distant metastasis, and peritoneal metastasis, were not significant. The most common recurrence patterns were loco-regional in the IHCP group and peritoneal in the control group. Complete cytoreductive surgery plus IHCP is effective to prevent and to treat peritoneal metastasis, and it should lead to long-term survival for serosa-invasive gastric carcinoma patients

  12. Robotic-assisted versus laparoscopic colorectal surgery: a meta-analysis of four randomized controlled trials

    Science.gov (United States)

    2014-01-01

    Background Robotic-assisted laparoscopy is popularly performed for colorectal disease. The objective of this meta-analysis was to compare the safety and efficacy of robotic-assisted colorectal surgery (RCS) and laparoscopic colorectal surgery (LCS) for colorectal disease based on randomized controlled trial studies. Methods Literature searches of electronic databases (Pubmed, Web of Science, and Cochrane Library) were performed to identify randomized controlled trial studies that compared the clinical or oncologic outcomes of RCS and LCS. This meta-analysis was performed using the Review Manager (RevMan) software (version 5.2) that is provided by the Cochrane Collaboration. The data used were mean differences and odds ratios for continuous and dichotomous variables, respectively. Fixed-effects or random-effects models were adopted according to heterogeneity. Results Four randomized controlled trial studies were identified for this meta-analysis. In total, 110 patients underwent RCS, and 116 patients underwent LCS. The results revealed that estimated blood losses (EBLs), conversion rates and times to the recovery of bowel function were significantly reduced following RCS compared with LCS. There were no significant differences in complication rates, lengths of hospital stays, proximal margins, distal margins or harvested lymph nodes between the two techniques. Conclusions RCS is a promising technique and is a safe and effective alternative to LCS for colorectal surgery. The advantages of RCS include reduced EBLs, lower conversion rates and shorter times to the recovery of bowel function. Further studies are required to define the financial effects of RCS and the effects of RCS on long-term oncologic outcomes. PMID:24767102

  13. Surgery with cooperative robots.

    Science.gov (United States)

    Lehman, Amy C; Berg, Kyle A; Dumpert, Jason; Wood, Nathan A; Visty, Abigail Q; Rentschler, Mark E; Platt, Stephen R; Farritor, Shane M; Oleynikov, Dmitry

    2008-03-01

    Advances in endoscopic techniques for abdominal procedures continue to reduce the invasiveness of surgery. Gaining access to the peritoneal cavity through small incisions prompted the first significant shift in general surgery. The complete elimination of external incisions through natural orifice access is potentially the next step in reducing patient trauma. While minimally invasive techniques offer significant patient advantages, the procedures are surgically challenging. Robotic surgical systems are being developed that address the visualization and manipulation limitations, but many of these systems remain constrained by the entry incisions. Alternatively, miniature in vivo robots are being developed that are completely inserted into the peritoneal cavity for laparoscopic and natural orifice procedures. These robots can provide vision and task assistance without the constraints of the entry incision, and can reduce the number of incisions required for laparoscopic procedures. In this study, a series of minimally invasive animal-model surgeries were performed using multiple miniature in vivo robots in cooperation with existing laparoscopy and endoscopy tools as well as the da Vinci Surgical System. These procedures demonstrate that miniature in vivo robots can address the visualization constraints of minimally invasive surgery by providing video feedback and task assistance from arbitrary orientations within the peritoneal cavity.

  14. Robotics in medicine

    Science.gov (United States)

    Kuznetsov, D. N.; Syryamkin, V. I.

    2015-11-01

    Modern technologies play a very important role in our lives. It is hard to imagine how people can get along without personal computers, and companies - without powerful computer centers. Nowadays, many devices make modern medicine more effective. Medicine is developing constantly, so introduction of robots in this sector is a very promising activity. Advances in technology have influenced medicine greatly. Robotic surgery is now actively developing worldwide. Scientists have been carrying out research and practical attempts to create robotic surgeons for more than 20 years, since the mid-80s of the last century. Robotic assistants play an important role in modern medicine. This industry is new enough and is at the early stage of development; despite this, some developments already have worldwide application; they function successfully and bring invaluable help to employees of medical institutions. Today, doctors can perform operations that seemed impossible a few years ago. Such progress in medicine is due to many factors. First, modern operating rooms are equipped with up-to-date equipment, allowing doctors to make operations more accurately and with less risk to the patient. Second, technology has enabled to improve the quality of doctors' training. Various types of robots exist now: assistants, military robots, space, household and medical, of course. Further, we should make a detailed analysis of existing types of robots and their application. The purpose of the article is to illustrate the most popular types of robots used in medicine.

  15. Autism and social robotics: A systematic review.

    Science.gov (United States)

    Pennisi, Paola; Tonacci, Alessandro; Tartarisco, Gennaro; Billeci, Lucia; Ruta, Liliana; Gangemi, Sebastiano; Pioggia, Giovanni

    2016-02-01

    Social robotics could be a promising method for Autism Spectrum Disorders (ASD) treatment. The aim of this article is to carry out a systematic literature review of the studies on this topic that were published in the last 10 years. We tried to address the following questions: can social robots be a useful tool in autism therapy? We followed the PRISMA guidelines, and the protocol was registered within PROSPERO database (CRD42015016158). We found many positive implications in the use of social robots in therapy as for example: ASD subjects often performed better with a robot partner rather than a human partner; sometimes, ASD patients had, toward robots, behaviors that TD patients had toward human agents; ASDs had a lot of social behaviors toward robots; during robotic sessions, ASDs showed reduced repetitive and stereotyped behaviors and, social robots manage to improve spontaneous language during therapy sessions. Therefore, robots provide therapists and researchers a means to connect with autistic subjects in an easier way, but studies in this area are still insufficient. It is necessary to clarify whether sex, intelligence quotient, and age of participants affect the outcome of therapy and whether any beneficial effects only occur during the robotic session or if they are still observable outside the clinical/experimental context. © 2015 International Society for Autism Research, Wiley Periodicals, Inc.

  16. Early biochemical recurrence, urinary continence and potency outcomes following robot-assisted radical prostatectomy

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Thomsen, Frederik Birkebæk; Hvarness, Helle

    2014-01-01

    OBJECTIVE: The aim of this study was to describe recovery of urinary continence and potency and report oncological and functional outcomes using the survival, continence and potency (SCP) system for patients undergoing robot-assisted radical prostatectomy (RARP). MATERIAL AND METHODS: From 2009...... with preoperative ESI, 77.6% (67.9-86.1) and 34.4% (24.1-47.5) maintained ESI 12 months postoperatively after bilateral and unilateral nerve-sparing surgery (NS), respectively. NS (p .... Using the SCP system and defining potency as ESI, functional and oncological success 12 months after surgery was achieved in 69 out of 135 (51.1%) preoperative continent and potent patients who underwent unilateral or bilateral NS, and did not require adjuvant treatment; when defining potency as IIEF...

  17. Robotic partial nephrectomy for renal cell carcinomas with venous tumor thrombus.

    Science.gov (United States)

    Abaza, Ronney; Angell, Jordan

    2013-06-01

    To describe the first report of robotic partial nephrectomies (RPNs) for renal cell carcinoma (RCC) with venous tumor thrombus (VTT). Partial nephrectomy for RCC extending into the renal vein has been described in limited fashion, but such a complex procedure has not previously been reported in minimally-invasive fashion. We demonstrate the feasibility of robotic nephron-sparing surgery despite vein thrombi and the results of the initial four highly-selected patients to have undergone this novel procedure. Two patients underwent RPN for RCC with VTT involving intraparenchymal vein branches, and 2 others had VTT involving the main renal vein. Mean patient age was 65 years (range 50-74 years). Mean tumor size was 7.75 cm (range 4.3-12.8 cm) with mean RENAL (radius, exophytic/endophytic, nearness to collecting system, anterior/posterior, and location) nephrometry score of 9.75 (range 8-12). Mean warm ischemia time was 24.2 minutes (range 19-27 minutes) and mean estimated blood loss was 168.8 mL (range 100-300 mL). No patients required transfusion, and there were no intraoperative complications. No patients required conversion to open or standard laparoscopic surgery. All 4 patients were discharged home on the first postoperative day. A single postoperative complication occurred in 1 patient who was readmitted with an ileus that resolved spontaneously. All patients had negative surgical margins. Two patients developed metastatic disease on surveillance imaging. RPN in patients with VTT is safe and feasible in selected patients. Given the risk of metastatic disease in patients with pathologic stage T3a RCC, the role of nephron sparing requires further evaluation such that radical nephrectomy remains the standard of care. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Hand Robotic Therapy in Children with Hemiparesis: A Pilot Study.

    Science.gov (United States)

    Bishop, Lauri; Gordon, Andrew M; Kim, Heakyung

    2017-01-01

    The aim of this study was to understand the impact of training with a hand robotic device on hand paresis and function in a population of children with hemiparesis. Twelve children with hemiparesis (mean age, 9 [SD, 3.64] years) completed participation in this prospective, experimental, pilot study. Participants underwent clinical assessments at baseline and again 6 weeks later with instructions to not initiate new therapies. After these assessments, participants received 6 weeks of training with a hand robotic device, consisting of 1-hour sessions, 3 times weekly. Assessments were repeated on completion of training. Results showed significant improvements after training on the Assisting Hand Assessment (mean difference, 2.0 Assisting Hand Assessment units; P = 0.011) and on the upper-extremity component of the Fugl-Meyer scale (raw score mean difference, 4.334; P = 0.001). No significant improvements between pretest and posttest were noted on the Jebsen-Taylor Test of Hand Function, the Quality of Upper Extremity Skills Test, or the Pediatric Evaluation of Disability Inventory after intervention. Total active mobility of digits and grip strength also failed to demonstrate significant changes after training. Participants tolerated training with the hand robotic device, and significant improvements in bimanual hand use, as well as impairment-based scales, were noted. Improvements were carried over into bimanual skills during play. Complete the self-assessment activity and evaluation online at http://www.physiatry.org/JournalCME CME OBJECTIVES: Upon completion of this article, the reader should be able to: (1) Understand key components of neuroplasticity; (2) Discuss the benefits of robotic therapy in the recovery of hand function in pediatric patients with hemiplegia; and (3) Appropriately incorporate robotic therapy into the treatment plan of pediatric patients with hemiplegia. Advanced ACCREDITATION: The Association of Academic Physiatrists is accredited by the

  19. Development of an Upper Limb Motorized Assistive-Rehabilitative Robot

    Science.gov (United States)

    Amiri, Masoud; Casolo, Federico

    While the number of people requiring help for the activities of daily living are increasing, several studies have been shown the effectiveness of robot training for upper limb functionality recovery. The robotic system described in this paper is an active end-effector based robot which can be used for assisting and rehabilitating of human upper limb. The robot is able to take into account desire of the patient for the support that patient needs to complete the task.

  20. Accuracy of S2 Alar-Iliac Screw Placement Under Robotic Guidance.

    Science.gov (United States)

    Laratta, Joseph L; Shillingford, Jamal N; Lombardi, Joseph M; Alrabaa, Rami G; Benkli, Barlas; Fischer, Charla; Lenke, Lawrence G; Lehman, Ronald A

    Case series. To determine the safety and feasibility of S2 alar-iliac (S2AI) screw placement under robotic guidance. Similar to standard iliac fixation, S2AI screws aid in achieving fixation across the sacropelvic junction and decreasing S1 screw strain. Fortunately, the S2AI technique minimizes prominent instrumentation and the need for offset connectors to the fusion construct. Herein, we present an analysis of the largest series of robotic-guided S2AI screws in the literature without any significant author conflicts of interest with the robotics industry. Twenty-three consecutive patients who underwent spinopelvic fixation with 46 S2AI screws under robotic guidance were analyzed from 2015 to 2016. Screws were placed by two senior spine surgeons, along with various fellow or resident surgical assistants, using a proprietary robotic guidance system (Renaissance; Mazor Robotics Ltd., Caesara, Israel). Screw position and accuracy was assessed on intraoperative CT O-arm scans and analyzed using three-dimensional interactive viewing and manipulation of the images. The average caudal angle in the sagittal plane was 31.0° ± 10.0°. The average horizontal angle in the axial plane using the posterior superior iliac spine as a reference was 42.8° ± 6.6°. The average S1 screw to S2AI screw angle was 11.3° ± 9.9°. Two violations of the iliac cortex were noted, with an average breach distance of 7.9 ± 4.8 mm. One breach was posterior (2.2%) and one was anterior (2.2%). The overall robotic S2AI screw accuracy rate was 95.7%. There were no intraoperative neurologic, vascular, or visceral complications related to the placement of the S2AI screws. Spinopelvic fixation achieved using a bone-mounted miniature robotic-guided S2AI screw insertion technique is safe and reliable. Despite two breaches, no complications related to the placement of the S2AI screws occurred in this series. Level IV, therapeutic. Copyright © 2017 Scoliosis Research Society. Published by Elsevier

  1. The robotic appendicovesicostomy and bladder augmentation: the next frontier in robotics, are we there?

    Science.gov (United States)

    Cohen, Andrew J; Pariser, Joseph J; Anderson, Blake B; Pearce, Shane M; Gundeti, Mohan S

    2015-02-01

    There is growing interest in applying robotic-assisted laparoscopic techniques to complex reconstructive pelvic surgery owing to inherent benefits of precision, tissue handling, and articulating instruments for suturing. This review examines preliminary experiences with robotic-assisted laparoscopic augmentation ileocystoplasty and Mitrofanoff appendicovesicostomy (RALIMA) as either an isolated or combined procedure. These series suggest RALIMA is feasible, with the benefit of early recovery and improved cosmetic results in selected patients. The robotic approach incurs functional outcomes and complication rates similar to those of open techniques. Given the steep learning curve, only surgeons with extensive robotic experience are currently adopting this technique. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Robotic Exoskeletons: A Perspective for the Rehabilitation of Arm Coordination in Stroke Patients

    Science.gov (United States)

    Jarrassé, Nathanaël; Proietti, Tommaso; Crocher, Vincent; Robertson, Johanna; Sahbani, Anis; Morel, Guillaume; Roby-Brami, Agnès

    2014-01-01

    Upper-limb impairment after stroke is caused by weakness, loss of individual joint control, spasticity, and abnormal synergies. Upper-limb movement frequently involves abnormal, stereotyped, and fixed synergies, likely related to the increased use of sub-cortical networks following the stroke. The flexible coordination of the shoulder and elbow joints is also disrupted. New methods for motor learning, based on the stimulation of activity-dependent neural plasticity have been developed. These include robots that can adaptively assist active movements and generate many movement repetitions. However, most of these robots only control the movement of the hand in space. The aim of the present text is to analyze the potential of robotic exoskeletons to specifically rehabilitate joint motion and particularly inter-joint coordination. First, a review of studies on upper-limb coordination in stroke patients is presented and the potential for recovery of coordination is examined. Second, issues relating to the mechanical design of exoskeletons and the transmission of constraints between the robotic and human limbs are discussed. The third section considers the development of different methods to control exoskeletons: existing rehabilitation devices and approaches to the control and rehabilitation of joint coordinations are then reviewed, along with preliminary clinical results available. Finally, perspectives and future strategies for the design of control mechanisms for rehabilitation exoskeletons are discussed. PMID:25520638

  3. Design of 3-D Printed Concentric Tube Robots.

    Science.gov (United States)

    Morimoto, Tania K; Okamura, Allison M

    2016-12-01

    Concentric tube surgical robots are minimally invasive devices with the advantages of snake-like reconfigurability, long and thin form factor, and placement of actuation outside the patient's body. These robots can also be designed and manufactured to acquire targets in specific patients for treating specific diseases in a manner that minimizes invasiveness. We propose that concentric tube robots can be manufactured using 3-D printing technology on a patient- and procedure-specific basis. In this paper, we define the design requirements and manufacturing constraints for 3-D printed concentric tube robots and experimentally demonstrate the capabilities of these robots. While numerous 3-D printing technologies and materials can be used to create such robots, one successful example uses selective laser sintering to make an outer tube with a polyether block amide and uses stereolithography to make an inner tube with a polypropylene-like material. This enables a tube pair with precurvatures of 0.0775 and 0.0455 mm -1 , which can withstand strains of 20% and 5.5% for the outer and inner tubes, respectively.

  4. Long-term interventions effects of robotic training on patients after anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Zhou, Yue; Gu, Rui; Ye, Miao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng

    2016-08-01

    [Purpose] The aim of this study was to examine the long-term interventions effects of robot-assisted therapy rehabilitation on functional activity levels after anterior cruciate ligament reconstruction. [Subjects and Methods] The subjects were 8 patients (6 males and 2 females) who received anterior cruciate ligament reconstruction. The subjects participated in robot-assisted therapy lasting for one month. The Timed Up-and-Go test, 10-Meter Walk test, Functional Reach Test, surface electromyography of the vastus lateralis and vastus medialis, and extensor strength of isokinetic movement of the knee joint were evaluated before and after the intervention. [Results] The average value of the of vastus medialis EMG, Functional Reach Test, and the maximum and average extensor strength of the knee joint isokinetic movement increased significantly, and the time of the 10-Meter Walk test decreased significantly. [Conclusion] These results suggest that walking ability and muscle strength can be improved by robotic walking training as a long-term intervention.

  5. Cultural Robotics: The Culture of Robotics and Robotics in Culture

    Directory of Open Access Journals (Sweden)

    Hooman Samani

    2013-12-01

    Full Text Available In this paper, we have investigated the concept of “Cultural Robotics” with regard to the evolution of social into cultural robots in the 21st Century. By defining the concept of culture, the potential development of a culture between humans and robots is explored. Based on the cultural values of the robotics developers, and the learning ability of current robots, cultural attributes in this regard are in the process of being formed, which would define the new concept of cultural robotics. According to the importance of the embodiment of robots in the sense of presence, the influence of robots in communication culture is anticipated. The sustainability of robotics culture based on diversity for cultural communities for various acceptance modalities is explored in order to anticipate the creation of different attributes of culture between robots and humans in the future.

  6. Attitudes and reactions to a healthcare robot.

    Science.gov (United States)

    Broadbent, Elizabeth; Kuo, I Han; Lee, Yong In; Rabindran, Joel; Kerse, Ngaire; Stafford, Rebecca; MacDonald, Bruce A

    2010-06-01

    The use of robots in healthcare is a new concept. The public's perception and acceptance is not well understood. The objective was to investigate the perceptions and emotions toward the utilization of healthcare robots among individuals over 40 years of age, investigate factors contributing to acceptance, and evaluate differences in blood pressure checks taken by a robot and a medical student. Fifty-seven (n = 57) adults aged over 40 years and recruited from local general practitioner or gerontology group lists participated in two cross-sectional studies. The first was an open-ended questionnaire assessing perceptions of robots. In the second study, participants had their blood pressure taken by a medical student and by a robot. Patient comfort with each encounter, perceived accuracy of each measurement, and the quality of the patient interaction were studied in each case. Readings were compared by independent t-tests and regression analyses were conducted to predict quality ratings. Participants' perceptions about robots were influenced by their prior exposure to robots in literature or entertainment media. Participants saw many benefits and applications for healthcare robots, including simple medical procedures and physical assistance, but had some concerns about reliability, safety, and the loss of personal care. Blood pressure readings did not differ between the medical student and robot, but participants felt more comfortable with the medical student and saw the robot as less accurate. Although age and sex were not significant predictors, individuals who held more positive initial attitudes and emotions toward robots rated the robot interaction more favorably. Many people see robots as having benefits and applications in healthcare but some have concerns. Individual attitudes and emotions regarding robots in general are likely to influence future acceptance of their introduction into healthcare processes.

  7. Friendly network robotics; Friendly network robotics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This paper summarizes the research results on the friendly network robotics in fiscal 1996. This research assumes an android robot as an ultimate robot and the future robot system utilizing computer network technology. The robot aiming at human daily work activities in factories or under extreme environments is required to work under usual human work environments. The human robot with similar size, shape and functions to human being is desirable. Such robot having a head with two eyes, two ears and mouth can hold a conversation with human being, can walk with two legs by autonomous adaptive control, and has a behavior intelligence. Remote operation of such robot is also possible through high-speed computer network. As a key technology to use this robot under coexistence with human being, establishment of human coexistent robotics was studied. As network based robotics, use of robots connected with computer networks was also studied. In addition, the R-cube (R{sup 3}) plan (realtime remote control robot technology) was proposed. 82 refs., 86 figs., 12 tabs.

  8. Retrospective, Demographic, and Clinical Investigation of the Causes of Postoperative Infection in Patients With Lumbar Spinal Stenosis Who Underwent Posterior Stabilization.

    Science.gov (United States)

    Yaldiz, Can; Yaldiz, Mahizer; Ceylan, Nehir; Kacira, Ozlem Kitiki; Ceylan, Davut; Kacira, Tibet; Kizilcay, Gokhan; Tanriverdi, Taner

    2015-07-01

    Owing to the increasing population of elderly patients, a large number of patients with degenerative spondylosis are currently being surgically treated. Although basic measures for decreasing postoperative surgical infections (PSIs) are considered, it still remains among the leading causes of morbidity and mortality. The aim of this retrospective analysis is to present possible causes leading to PSI in patients who underwent surgery for lumbar degenerative spondylosis and highlight how it can be avoided to decrease morbidity and mortality. The study included 540 patients who underwent posterior stabilization due to degenerative lumbar stenosis between January 2013 and January 2014. The data before and after surgery was retrieved from the hospital charts. Patients with degenerative lumbar stenosis who were operated upon in this study had >2 levels of laminectomy and facetectomy. For this reason, posterior stabilization was performed for all the patients included in this study. Determining the causes of postoperative infection (PI) following spinal surgeries performed with instrumentation is a struggle. Seventeen different parameters that may be related to PI were evaluated in this study. The presence of systemic diseases, unknown glove perforations, and perioperative blood transfusions were among the parameters that increased the prevalence of PI. Alternatively, prolene sutures, double-layered gloves, and the use of rifampicin Sv (RIS) decreased the incidence of PI. Although the presence of systemic diseases, unnoticed glove perforations, and perioperative blood transfusions increased PIs, prolene suture material, double-layered gloves, and the use of RIS decreased PIs.

  9. Vascular Surgery and Robotics

    Directory of Open Access Journals (Sweden)

    Indrani Sen

    2016-01-01

    Full Text Available The application of robotics to Vascular surgery has not progressed as rapidly as of endovascular technology, but this is changing with the amalgamation of these two fields. The advent of Endovascular robotics is an exciting field which overcomes many of the limitations of endovascular therapy like vessel tortuosity and operator fatigue. This has much clinical appeal for the surgeon and hold significant promise of better patient outcomes. As with most newer technological advances, it is still limited by cost and availability. However, this field has seen some rapid progress in the last decade with the technology moving into the clinical realm. This review details the development of robotics, applications, outcomes, advantages, disadvantages and current advances focussing on Vascular and Endovascular robotics

  10. Robotics in Colorectal Surgery

    Science.gov (United States)

    Weaver, Allison; Steele, Scott

    2016-01-01

    Over the past few decades, robotic surgery has developed from a futuristic dream to a real, widely used technology. Today, robotic platforms are used for a range of procedures and have added a new facet to the development and implementation of minimally invasive surgeries. The potential advantages are enormous, but the current progress is impeded by high costs and limited technology. However, recent advances in haptic feedback systems and single-port surgical techniques demonstrate a clear role for robotics and are likely to improve surgical outcomes. Although robotic surgeries have become the gold standard for a number of procedures, the research in colorectal surgery is not definitive and more work needs to be done to prove its safety and efficacy to both surgeons and patients. PMID:27746895

  11. Comportamiento de los pacientesancianosoperados de cirugíacardíaca con circulaciónextracorpórea/ Evolution of elderly patients who underwent cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Alain Moré Duarte

    2015-10-01

    Full Text Available Introduction: There is a steady increase in the number of elderly patients with severe cardiovascular diseases who require a surgical procedure to recover some quality of life that allows them a socially meaningful existence, despite the risks. Objectives: To analyze the behavior of elderly patients who underwent cardiac surgery with cardiopulmonary bypass. Method: A descriptive, retrospective, cross-sectional study was conducted with patients over 65 years of age who underwent surgery at the Cardiocentro Ernesto Che Guevara, in Santa Clara, from January 2013 to March 2014. Results: In the study, 73.1% of patients were men; and there was a predominance of subjects between 65 and 70 years of age, accounting for 67.3%. Coronary artery bypass graft was the most prevalent type of surgery and had the longest cardiopulmonary bypass times. Hypertension was present in 98.1% of patients. The most frequent postoperative complications were renal dysfunction and severe low cardiac output, with 44.2% and 34.6% respectively. Conclusions: There was a predominance of men, the age group of 65 to 70 years, hypertension, and patients who underwent coronary artery bypass graft with prolonged cardiopulmonary bypass. Renal dysfunction was the most frequent complication.

  12. Robot vision for nuclear advanced robot

    International Nuclear Information System (INIS)

    Nakayama, Ryoichi; Okano, Hideharu; Kuno, Yoshinori; Miyazawa, Tatsuo; Shimada, Hideo; Okada, Satoshi; Kawamura, Astuo

    1991-01-01

    This paper describes Robot Vision and Operation System for Nuclear Advanced Robot. This Robot Vision consists of robot position detection, obstacle detection and object recognition. With these vision techniques, a mobile robot can make a path and move autonomously along the planned path. The authors implemented the above robot vision system on the 'Advanced Robot for Nuclear Power Plant' and tested in an environment mocked up as nuclear power plant facilities. Since the operation system for this robot consists of operator's console and a large stereo monitor, this system can be easily operated by one person. Experimental tests were made using the Advanced Robot (nuclear robot). Results indicate that the proposed operation system is very useful, and can be operate by only person. (author)

  13. Effects of robotic treadmill training on functional mobility, walking capacity, motor symptoms and quality of life in ambulatory patients with Parkinson's disease: a preliminary prospective longitudinal study.

    Science.gov (United States)

    Paker, Nurdan; Bugdayci, Derya; Goksenoglu, Goksen; Sen, Aysu; Kesiktas, Nur

    2013-01-01

    Decreased mobility and walking capacity occur frequently in Parkinson's disease (PD). Robotic treadmill training is a novel method to improve the walking capacity in rehabilitation. The primary aim of this study was to investigate the effects of robotic treadmill training on functional mobility and walking capacity in PD. Secondly, we aimed to assess the effects of the robotic treadmill training the motor symptoms and quality of life in patients with PD. Seventy patients with idiopathic Parkinson's disease who admitted to the outpatient clinic of the rehabilitation hospital were screened and 12 ambulatory volenteers who met the study criteria were included in this study. Patients were evaluated by Hoehn Yahr (HY) scale clinically. Two sessions robotic treadmill training per week during 5 weeks was planned for every patient. Patients were evaluated by the Timed Up and Go (TUG) test, 10 meter walking test (10 MWT), Unified Parkinson's Disease Rating Scale (UPDRS) motor section and Parkinson's Disease Questionnaire-39 (PDQ-39) at the baseline, at the 5 and 12 weeks. Cognitive and emotional states of the patients were assessed by Mini Mental State Examination (MMSE) test and Hospital Anxiety and Depression Scale (HADS) at the baseline. All patients were under medical treatment for the PD in this study and drug treatment was not changed during the study. Ten patients completed the study. The mean age was 65.6 ± 6.6 years. Five patients (50%) were women. Disease severity was between the HY stage 1-3. Two patients did not continue the robotic treadmill training after 7 sessions. They also did not want to come for control visits. TUG test, 10 MWT and UPDRS motor subscale scores showed statistically significant improvement after robotic treadmill training (p = 0.02, p = 0.001, p = 0.016). PDQ-39 scores improved significantly after robotic treadmill training (p = 0.03), however, the scores turned back to the baseline level at the 12. week control. As a result of this

  14. Contralateral prophylactic mastectomy rate and predictive factors among patients with breast cancer who underwent multigene panel testing for hereditary cancer.

    Science.gov (United States)

    Elsayegh, Nisreen; Webster, Rachel D; Gutierrez Barrera, Angelica M; Lin, Heather; Kuerer, Henry M; Litton, Jennifer K; Bedrosian, Isabelle; Arun, Banu K

    2018-05-07

    Although multigene panel testing is increasingly common in patients with cancer, the relationship between its use among breast cancer patients with non-BRCA mutations or variants of uncertain significance (VUS) and disease management decisions has not been well described. This study evaluated the rate and predictive factors of CPM patients who underwent multigene panel testing. Three hundred and fourteen patients with breast cancer who underwent multigene panel testing between 2014 and 2017 were included in the analysis. Of the 314 patients, 70 elected CPM. Election of CPM by gene status was as follows: BRCA carriers (42.3%), non-BRCA carriers (30.1%), and VUS (10.6%). CPM election rates did not differ between non-BRCA carriers and BRCA carriers (P = 0.6205). Among non-BRCA carriers, negative hormone receptor status was associated with CPM (P = 0.0115). For those with a VUS, hormone receptor status was not associated with CPM (P = 0.1879). Although the rate of CPM between BRCA carriers and non-BRCA carriers was not significantly different, the predictors of CPM were different in each group. Our analyses shed the light on the increasing use of CPM among patients who are non-BRCA carriers as well those with a VUS. Our study elucidates the differing predictive factors of CPM election among BRCA carriers, non-BRCA carries, and those with a VUS. Our findings reveal the need for providers to be cognizant that non-BRCA genes and VUS drive women to elect CPM despite the lack of data for contralateral breast cancer risk associated with these genes. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  15. Robotic Ureteroplasty with Buccal Mucosa Graft for the Management of Complex Ureteral Strictures.

    Science.gov (United States)

    Lee, Ziho; Waldorf, Benjamin T; Cho, Eric Y; Liu, Jeffrey C; Metro, Michael J; Eun, Daniel D

    2017-12-01

    Surgical management of proximal and mid ureteral strictures that are not amenable to primary excision and anastomosis is challenging. Although a buccal mucosa graft is commonly used during substitution urethroplasty, its use in substitution ureteroplasty is limited. We describe our technique of robotic ureteroplasty with a buccal mucosa graft to manage complex ureteral strictures and we report our outcomes. We retrospectively reviewed the records of 12 patients who underwent robotic ureteroplasty with a buccal mucosa graft between September 2014 and June 2016. The indication for the procedure was a proximal or mid ureteral stricture not amenable to primary excision and anastomosis. The primary outcomes were clinical success, absent symptoms on ureteral pathology and radiological success, defined as absent ureteral obstruction on retrograde pyelography, renal scan and/or computerized tomography. Four of the 12 patients (33.3%) had a ureteropelvic junction stricture, 4 (33.3%) had a proximal stricture and 4 (33.3%) had a mid ureteral stricture. Eight of the 12 patients (66.7%) had previously undergone failed ureteral reconstruction. Median stricture length was 3 cm (range 2 to 5). Median operative time was 217 minutes (range 136 to 344) and mean estimated blood loss was 100 ml (range 50 to 200). Median length of stay was 1 day (range 1 to 6). At a median followup of 13 months (range 4 to 30) 10 of the 12 cases (83.3%) were clinically and radiologically successful. Robotic ureteroplasty with a buccal mucosa graft is associated with low inherent morbidity. It is an effective way to manage complex proximal and mid ureteral strictures. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Design of 3-D Printed Concentric Tube Robots

    OpenAIRE

    Morimoto, Tania K.; Okamura, Allison M.

    2016-01-01

    Concentric tube surgical robots are minimally invasive devices with the advantages of snake-like reconfigurability, long and thin form factor, and placement of actuation outside the patient’s body. These robots can also be designed and manufactured to acquire targets in specific patients for treating specific diseases in a manner that minimizes invasiveness. We propose that concentric tube robots can be manufactured using 3-D printing technology on a patient- and procedure-specific basis. In ...

  17. Robotic technological aids in esophageal surgery.

    Science.gov (United States)

    Rebecchi, Fabrizio; Allaix, Marco E; Morino, Mario

    2017-01-01

    Robotic technology is an emerging technology that has been developed in order to overcome some limitations of the standard laparoscopic approach, offering a stereoscopic three-dimensional visualization of the surgical field, increased maneuverability of the surgical tools with consequent increased movement accuracy and precision and improved ergonomics. It has been used for the surgical treatment of most benign esophageal disorders. More recently, it has been proposed also for patients with operable esophageal cancer. The current evidence shows that there are no real benefits of the robotic technology over conventional laparoscopy in patients undergoing a fundoplication for gastroesophageal reflux disease (GERD), hiatal closure for giant hiatal hernia, or Heller myotomy for achalasia. A few small studies suggest potential advantages in patients undergoing redo surgery for failed fundoplication or Heller myotomy, but large comparative studies are needed to better clarify the role of the robotic technology in these patients. Robot-assisted esophagectomy seems to be safe and effective in selected patients; however, there are no data showing superiority of this approach over both conventional laparoscopic and open surgery. The short-term and long-term oncologic results of ongoing randomized controlled trials (RCTs) are awaited to validate this approach for the treatment of esophageal cancer.

  18. Stratified analysis of 800 Asian patients after robot-assisted radical prostatectomy with a median 64 months of follow up.

    Science.gov (United States)

    Abdel Raheem, Ali; Kim, Dae Keun; Santok, Glen Denmer; Alabdulaali, Ibrahim; Chung, Byung Ha; Choi, Young Deuk; Rha, Koon Ho

    2016-09-01

    To report the 5-year oncological outcomes of robot-assisted radical prostatectomy from the largest series ever reported from Asia. A retrospective analysis of 800 Asian patients who were treated with robot-assisted radical prostatectomy from July 2005 to May 2010 in the Department of Urology and Urological Science Institute, Yonsei University College of Medicine, Seoul, Korea was carried out. The primary end-point was to evaluate the biochemical recurrence. The secondary end-point was to show the biochemical recurrence-free survival, metastasis-free survival and cancer-specific survival. A total of 197 (24.65%), 218 (27.3%), and 385 (48.1%) patients were classified as low-, intermediate- and high-risk patients according to the D'Amico risk stratification risk criteria, respectively. The median follow-up period was 64 months (interquartile range 28-71 months). The overall incidence of positive surgical margin was 36.6%. There was biochemical recurrence in 183 patients (22.9%), 38 patients (4.8%) developed distant metastasis and 24 patients (3%) died from prostate cancer. Actuarial biochemical recurrence-free survival, metastasis-free survival, and cancer-specific survival rates at 5 years were 76.4%, 94.6% and 96.7%, respectively. Positive lymph node was associated with lower 5-year biochemical recurrence-free survival (9.1%), cancer-specific survival (75.7%) and metastasis-free survival (61.9%) rates (P < 0.001). On multivariable analysis, among all the predictors, positive lymph node was the strongest predictor of biochemical recurrence, cancer-specific survival and metastasis-free survival (P < 0.001). Herein we report the largest robot-assisted radical prostatectomy series from Asia. Robot-assisted radical prostatectomy is confirmed to be an oncologically safe procedure that is able to provide effective 5-year cancer control, even in patients with high-risk disease. © 2016 The Japanese Urological Association.

  19. Robotic-assisted versus laparoscopic colectomy: cost and clinical outcomes.

    Science.gov (United States)

    Davis, Bradley R; Yoo, Andrew C; Moore, Matt; Gunnarsson, Candace

    2014-01-01

    Laparoscopic colectomies, with and without robotic assistance, are performed to treat both benign and malignant colonic disease. This study compared clinical and economic outcomes for laparoscopic colectomy procedures with and without robotic assistance. Patients aged ≥18 years having primary inpatient laparoscopic colectomy procedures (cecectomy, right hemicolectomy, left hemicolectomy, and sigmoidectomy) identified by International Classification of Diseases, Ninth Edition procedure codes performed between 2009 and the second quarter of 2011 from the Premier Hospital Database were studied. Patients were matched to a control cohort using propensity scores for disease, comorbidities, and hospital characteristics and were matched 1:1 for specific colectomy procedure. The outcomes of interest were hospital cost of laparoscopic robotic-assisted colectomy compared with traditional laparoscopic colectomy, surgery time, adverse events, and length of stay. Of 25,758 laparoscopic colectomies identified, 98% were performed without robotic assistance and 2% were performed with robotic assistance. After matching, 1066 patients remained, 533 in each group. Lengths of stay were not significantly different between the matched cohorts, nor were rates of major, minor, and/or surgical complications. Inpatient procedures with robotic assistance were significantly more costly than those without robotic assistance ($17,445 vs $15,448, P = .001). Operative times were significantly longer for robotic-assisted procedures (4.37 hours vs 3.34 hours, P < .001). Segmental colectomies can be performed safely by either laparoscopic or robotic-assisted methods. Increased per-case hospital costs for robotic-assisted procedures and prolonged operative times suggest that further investigation is warranted when considering robotic technology for routine laparoscopic colectomies.

  20. Robot-supported assessment of balance in standing and walking.

    Science.gov (United States)

    Shirota, Camila; van Asseldonk, Edwin; Matjačić, Zlatko; Vallery, Heike; Barralon, Pierre; Maggioni, Serena; Buurke, Jaap H; Veneman, Jan F

    2017-08-14

    Clinically useful and efficient assessment of balance during standing and walking is especially challenging in patients with neurological disorders. However, rehabilitation robots could facilitate assessment procedures and improve their clinical value. We present a short overview of balance assessment in clinical practice and in posturography. Based on this overview, we evaluate the potential use of robotic tools for such assessment. The novelty and assumed main benefits of using robots for assessment are their ability to assess 'severely affected' patients by providing assistance-as-needed, as well as to provide consistent perturbations during standing and walking while measuring the patient's reactions. We provide a classification of robotic devices on three aspects relevant to their potential application for balance assessment: 1) how the device interacts with the body, 2) in what sense the device is mobile, and 3) on what surface the person stands or walks when using the device. As examples, nine types of robotic devices are described, classified and evaluated for their suitability for balance assessment. Two example cases of robotic assessments based on perturbations during walking are presented. We conclude that robotic devices are promising and can become useful and relevant tools for assessment of balance in patients with neurological disorders, both in research and in clinical use. Robotic assessment holds the promise to provide increasingly detailed assessment that allows to individually tailor rehabilitation training, which may eventually improve training effectiveness.

  1. Robotic repair of vesicovaginal fistula - initial experience

    Directory of Open Access Journals (Sweden)

    Ankush Jairath

    2016-02-01

    Full Text Available ABSTRACT Objective The most common acquired fistula of the urinary tract is Vesicovaginal fistulae (VVF (1 posing social stigmata for the patient as well as a surgical challenge for the urologist. Here we present our initial experience with Robotic assisted laparoscopic repair of VVF, its safety and efficacy. Materials and Methods Seven out of eight fistulas were post hysterectomy; five had undergone abdominal while two had laparoscopic hysterectomy while one was due to prolonged labour. Two had associated ureteric injury. All underwent robotic assisted laparoscopic trans abdominal extravesical approach. Three 8 mm ports for robotic arms, one 12 mm port for camera and another 12 mm for assistant were used in a fan shaped manner. All had preoperative ureteric catheter placed. Bladder was closed in two layers and vagina in one layer. Omental flap placed in all cases except two where it was not possible. Drain and per urethral catheter placed in all cases. Double J stents were placed in two cases requiring ureteric implantation additionally. Results The mean age of presentation was 39.25 years (26-47 range with mean BMI being 26.25 kg/m2 (21-32 range. Mean duration between insult and repair was 9.37 months (3-24 months. Only in single case there was history of previous repair attempt. On cystoscopy four had supratrigonal VVF and four were trigonal with mean size of 13.37 mm (7-20 mm. Mean operative time was 117.5 minutes (90-150. There were no intraoperative/postoperative complications or need for open conversion. Mean haemoglobin drop was 1.4 gm/dL (0.3-2 gm. Drain was removed once 24-48 hours output is negligible. One patient had post-operative urinary leak at 2 weeks which ceased with continuation of catheterisation for another 2 weeks. Catheter was removed after voiding cystourethrogram showed no leak at 2-3 weeks postoperatively. Mean duration of drain was 3.75 days (3-5 and per urethral catheterisation (which was removed after voiding

  2. Functional evaluation of the endotics system, a new disposable self-propelled robotic colonoscope: in vitro tests and clinical trial.

    Science.gov (United States)

    Cosentino, Felice; Tumino, Emanuele; Passoni, Giovanni Rubis; Morandi, Elisabetta; Capria, Alfonso

    2009-08-01

    Currently, the best method for CRC screening is colonoscopy, which ideally (where possible) is performed under partial or deep sedation. This study aims to evaluate the efficacy of the Endotics System, a new robotic device composed of a workstation and a disposable probe, in performing accurate and well-tolerated colonoscopies. This new system could also be considered a precursor of other innovating vectors for atraumatic locomotion through natural orifices such as the bowel. The flexible probe adapts its shape to the complex contours of the colon, thereby exerting low strenuous forces during its movement. These novel characteristics allow for a painless and safe colonoscopy, thus eliminating all major associated risks such as infection, cardiopulmonary complications and colon perforation. An experimental study was devised to investigate stress pattern differences between traditional and robotic colonoscopy, in which 40 enrolled patients underwent both robotic and standard colonoscopy within the same day. The stress pattern related to robotic colonoscopy was 90% lower than that of standard colonoscopy. Additionally, the robotic colonoscopy demonstrated a higher diagnostic accuracy, since, due to the lower insufflation rate, it was able to visualize small polyps and angiodysplasias not seen during the standard colonoscopy. All patients rated the robotic colonoscopy as virtually painless compared to the standard colonoscopy, ranking pain and discomfort as 0.9 and 1.1 respectively, on a scale of O to 10, versus 6.9 and 6.8 respectively for the standard device. The new Endotics System demonstrates efficacy in the diagnosis of colonic pathologies using a procedure nearly completely devoid of pain. Therefore, this system can also be looked upon as the first step toward developing and implementing colonoscopy with atraumatic locomotion through the bowel while maintaining a high level of diagnostic accuracy;

  3. Can Social Robots Qualify for Moral Consideration? Reframing the Question about Robot Rights

    Directory of Open Access Journals (Sweden)

    Herman T. Tavani

    2018-03-01

    Full Text Available A controversial question that has been hotly debated in the emerging field of robot ethics is whether robots should be granted rights. Yet, a review of the recent literature in that field suggests that this seemingly straightforward question is far from clear and unambiguous. For example, those who favor granting rights to robots have not always been clear as to which kinds of robots should (or should not be eligible; nor have they been consistent with regard to which kinds of rights—civil, legal, moral, etc.—should be granted to qualifying robots. Also, there has been considerable disagreement about which essential criterion, or cluster of criteria, a robot would need to satisfy to be eligible for rights, and there is ongoing disagreement as to whether a robot must satisfy the conditions for (moral agency to qualify either for rights or (at least some level of moral consideration. One aim of this paper is to show how the current debate about whether to grant rights to robots would benefit from an analysis and clarification of some key concepts and assumptions underlying that question. My principal objective, however, is to show why we should reframe that question by asking instead whether some kinds of social robots qualify for moral consideration as moral patients. In arguing that the answer to this question is “yes,” I draw from some insights in the writings of Hans Jonas to defend my position.

  4. CyberKnife robotic image-guided stereotactic radiotherapy for oligometastic cancer. A prospective evaluation of 95 patients/118 lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jereczek-Fossa, B.A.; Bossi-Zanetti, I.; Mauro, R. [European Institute of Oncology, Milan (Italy). Dept. of Radiotherapy; Milan Univ. (Italy); Beltramo, G.; Bianchi, L.C. [CyberKnife Center CDI, Milan (Italy); Fariselli, L. [Carlo Besta Neurological Institute Foundation, Milan (Italy). Radiotherapy Unit; Fodor, C. [European Institute of Oncology, Milan (Italy). Dept. of Radiotherapy; Fossati, P.; Orecchia, R. [European Institute of Oncology, Milan (Italy). Dept. of Radiotherapy; National Center for Oncological Hadrontherapy (CNAO) Foundation, Pavia, Milan (Italy); Milan Univ. (Italy); Baroni, G. [National Center for Oncological Hadrontherapy (CNAO) Foundation, Pavia, Milan (Italy); Politecnico di Milano (Italy). Dept. of Bioengineering

    2013-06-15

    Purpose: To evaluate the outcome of robotic CyberKnife (Accuray Inc. Sunnyvale, USA)-based stereotactic radiotherapy (CBK-SRT) for oligometastic cancer patients. Patients and methods: Between May 2007 and December 2009, 95 patients with a total of 118 lesions underwent CBK-SRT (median dose 24 Gy in 3 fractions). Inclusion criteria: adult patients with limited volume cancer; suitability for SRT but not for other local therapies. Primary diagnoses included breast, lung, head and neck, gastrointestinal and other malignancies. Prostate cancer patients were excluded. Concomitant systemic therapy was given in 40 % of cases and median follow-up was 12 months. Toxicity and tumor response were evaluated using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG/EORTC) Scale and Response Evaluation Criteria in Solid Tumors RECIST. Results: Toxicity was rare and observed mainly in patients with comorbidities or uncontrolled cancer. Out of 87 evaluable lesions, complete radiological response, partial response, stabilization and progressive disease were observed in 15 (17 %), 25 (29 %), 34 (39 %) and 13 (15 %) lesions, respectively. Upon restricting the analysis to lesions treated with CBK-SRT alone (no concomitant therapy), response- and local control (LC) rates remained similar. Actuarial 3-year in-field progression-free survival- (i.e. LC), progression-free survival- (PFS) and overall-survival (OS) rates were 67.6, 18.4, and 31.2 %, respectively. LC was reduced in cases of early recurrence. OS- and cause-specific survival (CSS) rates were significantly lower in patients treated for visceral lesions. Failures were predominantly out-field. Conclusion: CBK-SRT is a feasible therapeutic approach for oligometastastic cancer patients that provides long-term in-field tumor control with a low toxicity profile. Further investigations should focus on dose escalation and optimization of the combination with systemic therapies. (orig.)

  5. Citrus aurantium Naringenin Prevents Osteosarcoma Progression and Recurrence in the Patients Who Underwent Osteosarcoma Surgery by Improving Antioxidant Capability

    Directory of Open Access Journals (Sweden)

    Lirong Zhang

    2018-01-01

    Full Text Available Citrus aurantium is rich in flavonoids, which may prevent osteosarcoma progression, but its related molecular mechanism remains unclear. Flavonoids were extracted from C. aurantium and purified by reparative HPLC. Each fraction was identified by using electrospray ionisation mass spectrometry (ESI-MS. Three main components (naringin, naringenin, and hesperetin were isolated from C. aurantium. Naringenin inhibited the growth of MG-63 cells, whereas naringin and hesperetin had no inhibitory function on cell growth. ROS production was increased in naringin- and hesperetin-treated groups after one day of culture while the level was always lowest in the naringenin-treated group after three days of culture. 95 osteosarcoma patients who underwent surgery were assigned into two groups: naringenin group (NG, received 20 mg naringenin daily, n=47 and control group (CG, received 20 mg placebo daily, n=48. After an average of two-year follow-up, osteosarcoma volumes were smaller in the NG group than in the CG group (P>0.01. The rate of osteosarcoma recurrence was also lower in the NG group than in CG group. ROS levels were lower in the NG group than in the CG group. Thus, naringenin from Citrus aurantium inhibits osteosarcoma progression and local recurrence in the patients who underwent osteosarcoma surgery by improving antioxidant capability.

  6. Citrus aurantium Naringenin Prevents Osteosarcoma Progression and Recurrence in the Patients Who Underwent Osteosarcoma Surgery by Improving Antioxidant Capability.

    Science.gov (United States)

    Zhang, Lirong; Xu, Xiaohua; Jiang, Tiechao; Wu, Kunzhe; Ding, Chuanbo; Liu, Zhen; Zhang, Xuanhe; Yu, Tianhua; Song, Changlong

    2018-01-01

    Citrus aurantium is rich in flavonoids, which may prevent osteosarcoma progression, but its related molecular mechanism remains unclear. Flavonoids were extracted from C. aurantium and purified by reparative HPLC. Each fraction was identified by using electrospray ionisation mass spectrometry (ESI-MS). Three main components (naringin, naringenin, and hesperetin) were isolated from C. aurantium . Naringenin inhibited the growth of MG-63 cells, whereas naringin and hesperetin had no inhibitory function on cell growth. ROS production was increased in naringin- and hesperetin-treated groups after one day of culture while the level was always lowest in the naringenin-treated group after three days of culture. 95 osteosarcoma patients who underwent surgery were assigned into two groups: naringenin group (NG, received 20 mg naringenin daily, n = 47) and control group (CG, received 20 mg placebo daily, n = 48). After an average of two-year follow-up, osteosarcoma volumes were smaller in the NG group than in the CG group ( P > 0.01). The rate of osteosarcoma recurrence was also lower in the NG group than in CG group. ROS levels were lower in the NG group than in the CG group. Thus, naringenin from Citrus aurantium inhibits osteosarcoma progression and local recurrence in the patients who underwent osteosarcoma surgery by improving antioxidant capability.

  7. Upper-limb robot-assisted therapy in rehabilitation of acute stroke patients: focused review and results of new randomized controlled trial.

    Science.gov (United States)

    Masiero, Stefano; Armani, Mario; Rosati, Giulio

    2011-01-01

    The successful motor rehabilitation of stroke patients requires early intensive and task-specific therapy. A recent Cochrane Review, although based on a limited number of randomized controlled trials (RCTs), showed that early robotic training of the upper limb (i.e., during acute or subacute phase) can enhance motor learning and improve functional abilities more than chronic-phase training. In this article, a new subacute-phase RCT with the Neuro-Rehabilitation-roBot (NeReBot) is presented. While in our first study we used the NeReBot in addition to conventional therapy, in this new trial we used the same device in substitution of standard proximal upper-limb rehabilitation. With this protocol, robot patients achieved similar reductions in motor impairment and enhancements in paretic upper-limb function to those gained by patients in a control group. By analyzing these results and those of previous studies, we hypothesize a new robotic protocol for acute and subacute stroke patients based on both treatment modalities (in addition and in substitution).

  8. Robotic microsurgery in male infertility and urology-taking robotics to the next level.

    Science.gov (United States)

    Gudeloglu, Ahmet; Brahmbhatt, Jamin V; Parekattil, Sijo J

    2014-03-01

    The initial reports of robotic assisted microsurgery began to appear in the early 1990s. Animal and early human studies were the initial publications. Larger series papers have recently been published from a few institutions. The field of robotic assisted microsurgery is still in evolution and so are adjunctive tools and instruments. It is clearly a different and unique skill set-is it microsurgery or is it robotic surgery, or both. It is clear from history that the art of surgery evolves over time to encompass new technology as long as the outcomes are better for the patient. Our current robotic platforms may not be ideal for microsurgery, however, the use of adjunctive tools and instrument refinement will further its future potential. This review article presents the current state of the art in various robotic assisted microsurgical procedures in male infertility and urology. Some novel applications of taking microsurgery to areas not classically accessible (intra-abdominal vasovasostomy) and adjunctive tools will also be presented.

  9. Robot-assisted radical prostatectomy is a safe procedure

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebæk; Berg, Kasper Drimer; Hvarness, Helle

    2013-01-01

    We present our departmental experience with robot-assisted radical prostatectomy and describe complications and early results for the first 239 consecutive patients.......We present our departmental experience with robot-assisted radical prostatectomy and describe complications and early results for the first 239 consecutive patients....

  10. Robotics

    Science.gov (United States)

    Popov, E. P.; Iurevich, E. I.

    The history and the current status of robotics are reviewed, as are the design, operation, and principal applications of industrial robots. Attention is given to programmable robots, robots with adaptive control and elements of artificial intelligence, and remotely controlled robots. The applications of robots discussed include mechanical engineering, cargo handling during transportation and storage, mining, and metallurgy. The future prospects of robotics are briefly outlined.

  11. Gender-linked impact of epicardial adipose tissue volume in patients who underwent coronary artery bypass graft surgery or non-coronary valve surgery

    OpenAIRE

    Maimaituxun, Gulinu; Shimabukuro, Michio; Salim, Hotimah Masdan; Tabata, Minoru; Yuji, Daisuke; Morimoto, Yoshihisa; Akasaka, Takeshi; Matsuura, Tomomi; Yagi, Shusuke; Fukuda, Daiju; Yamada, Hirotsugu; Soeki, Takeshi; Sugimoto, Takaki; Tanaka, Masashi; Takanashi, Shuichiro

    2017-01-01

    Background Traditional and non-traditional risk factors for atherosclerotic cardiovascular disease (ASCVD) are different between men and women. Gender-linked impact of epicardial adipose tissue volume (EATV) in patients undergoing coronary artery bypass grafting (CABG) remains unknown. Methods Gender-linked impact of EATV, abdominal fat distribution and other traditional ASCVD risk factors were compared in 172 patients (men: 115; women: 57) who underwent CABG or non-coronary valvular surgery ...

  12. 30 Years of Robotic Surgery.

    Science.gov (United States)

    Leal Ghezzi, Tiago; Campos Corleta, Oly

    2016-10-01

    The idea of reproducing himself with the use of a mechanical robot structure has been in man's imagination in the last 3000 years. However, the use of robots in medicine has only 30 years of history. The application of robots in surgery originates from the need of modern man to achieve two goals: the telepresence and the performance of repetitive and accurate tasks. The first "robot surgeon" used on a human patient was the PUMA 200 in 1985. In the 1990s, scientists developed the concept of "master-slave" robot, which consisted of a robot with remote manipulators controlled by a surgeon at a surgical workstation. Despite the lack of force and tactile feedback, technical advantages of robotic surgery, such as 3D vision, stable and magnified image, EndoWrist instruments, physiologic tremor filtering, and motion scaling, have been considered fundamental to overcome many of the limitations of the laparoscopic surgery. Since the approval of the da Vinci(®) robot by international agencies, American, European, and Asian surgeons have proved its factibility and safety for the performance of many different robot-assisted surgeries. Comparative studies of robotic and laparoscopic surgical procedures in general surgery have shown similar results with regard to perioperative, oncological, and functional outcomes. However, higher costs and lack of haptic feedback represent the major limitations of current robotic technology to become the standard technique of minimally invasive surgery worldwide. Therefore, the future of robotic surgery involves cost reduction, development of new platforms and technologies, creation and validation of curriculum and virtual simulators, and conduction of randomized clinical trials to determine the best applications of robotics.

  13. An Evaluation of the Design and Usability of a Novel Robotic Bilateral Arm Rehabilitation Device for Patients with Stroke

    Directory of Open Access Journals (Sweden)

    Yu-Cheng Pei

    2017-07-01

    Full Text Available Study designCase series.Evidence levelIV (case series.IntroductionRobot-assisted therapy for upper limb rehabilitation is an emerging research topic and its design process must integrate engineering, neurological pathophysiology, and clinical needs.Purpose of the studyThis study developed/evaluated the usefulness of a novel rehabilitation device, the MirrorPath, designed for the upper limb rehabilitation of patients with hemiplegic stroke.MethodsThe process follows Tseng’s methodology for innovative product design and development, namely two stages, device development and usability assessment. During the development process, the design was guided by patients’ rehabilitation needs as defined by patients and their therapists. The design applied synchronic movement of the bilateral upper limbs, an approach that is compatible with the bilateral movement therapy and proprioceptive neuromuscular facilitation theories. MirrorPath consists of a robotic device that guides upper limb movement linked to a control module containing software controlling the robotic movement.ResultsFive healthy subjects were recruited in the pretest, and 4 patients, 4 caregivers, and 4 therapists were recruited in the formal test for usability. All recruited subjects were allocated to the test group, completed the evaluation, and their data were all analyzed. The total system usability scale score obtained from the patients, caregivers, and therapists was 71.8 ± 11.9, indicating a high level of usability and product acceptance.Discussion and conclusionFollowing a standard development process, we could yield a design that meets clinical needs. This low-cost device provides a feasible platform for carrying out robot-assisted bilateral movement therapy of patients with hemiplegic stroke.Clinical Trial Registrationidentifier NCT02698605.

  14. Robot 2015 : Second Iberian Robotics Conference : Advances in Robotics

    CERN Document Server

    Moreira, António; Lima, Pedro; Montano, Luis; Muñoz-Martinez, Victor

    2016-01-01

    This book contains a selection of papers accepted for presentation and discussion at ROBOT 2015: Second Iberian Robotics Conference, held in Lisbon, Portugal, November 19th-21th, 2015. ROBOT 2015 is part of a series of conferences that are a joint organization of SPR – “Sociedade Portuguesa de Robótica/ Portuguese Society for Robotics”, SEIDROB – Sociedad Española para la Investigación y Desarrollo de la Robótica/ Spanish Society for Research and Development in Robotics and CEA-GTRob – Grupo Temático de Robótica/ Robotics Thematic Group. The conference organization had also the collaboration of several universities and research institutes, including: University of Minho, University of Porto, University of Lisbon, Polytechnic Institute of Porto, University of Aveiro, University of Zaragoza, University of Malaga, LIACC, INESC-TEC and LARSyS. Robot 2015 was focussed on the Robotics scientific and technological activities in the Iberian Peninsula, although open to research and delegates from other...

  15. A comparison between robotic-assisted laparoscopic distal pancreatectomy versus laparoscopic distal pancreatectomy.

    Science.gov (United States)

    Goh, Brian K P; Chan, Chung Yip; Soh, Hui-Ling; Lee, Ser Yee; Cheow, Peng-Chung; Chow, Pierce K H; Ooi, London L P J; Chung, Alexander Y F

    2017-03-01

    This study aims to compare the early perioperative outcomes of robotic-assisted laparoscopic distal pancreatectomy (RDP) versus laparoscopic distal pancreatectomy (LDP). The clinicopathologic features of 45 consecutive patients who underwent minimally-invasive distal pancreatectomy from 2006 to 2015 were retrospectively reviewed. Thirty-nine patients who met our study criteria were included. Eight patients underwent RDP and 31 had LDP. There were 10 (25.6%) open conversions. Six (15.4%) patients had major (> grade 2) morbidities and there was no in-hospital mortality. There were 14 (35.9%) grade A and 9 (23.1%) grade B pancreatic fistulas. Comparison between RDP and LDP demonstrated no significant difference between the patients' baseline characteristics except there was increased frequency of spleen-preserving pancreatectomies (3 (37.5%) vs 25 (80.6%), P=0.016) and splenic-vessel preservation (5 (62.5%) vs 4 (12.9%), P=0.003) in RDP. Comparison between outcomes demonstrated that RDP was associated with a longer median operation time (452.5 (range, 300-685) vs 245 min (range, 85-430), P=0.001) and increased frequency of the procedure completed purely laparoscopically (8 (100%) vs 18 (58.1%), P=0.025). RDP can be safely adopted and is equivalent to LDP in most perioperative outcomes. It is also associated with a decreased frequency of the need for hand-assistance laparoscopic surgery or open conversion but needed a longer operation time. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Use of robotics in colon and rectal surgery.

    Science.gov (United States)

    Pucci, Michael J; Beekley, Alec C

    2013-03-01

    The pace of innovation in the field of surgery continues to accelerate. As new technologies are developed in combination with industry and clinicians, specialized patient care improves. In the field of colon and rectal surgery, robotic systems offer clinicians many alternative ways to care for patients. From having the ability to round remotely to improved visualization and dissection in the operating room, robotic assistance can greatly benefit clinical outcomes. Although the field of robotics in surgery is still in its infancy, many groups are actively investigating technologies that will assist clinicians in caring for their patients. As these technologies evolve, surgeons will continue to find new and innovative ways to utilize the systems for improved patient care and comfort.

  17. On the reproducibility of expert-operated and robotic ultrasound acquisitions.

    Science.gov (United States)

    Kojcev, Risto; Khakzar, Ashkan; Fuerst, Bernhard; Zettinig, Oliver; Fahkry, Carole; DeJong, Robert; Richmon, Jeremy; Taylor, Russell; Sinibaldi, Edoardo; Navab, Nassir

    2017-06-01

    We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging. Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface. After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements. A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.

  18. Robotic liver surgery: results for 70 resections.

    Science.gov (United States)

    Giulianotti, Pier Cristoforo; Coratti, Andrea; Sbrana, Fabio; Addeo, Pietro; Bianco, Francesco Maria; Buchs, Nicolas Christian; Annechiarico, Mario; Benedetti, Enrico

    2011-01-01

    Robotic surgery is gaining popularity for digestive surgery; however, its use for liver surgery is reported scarcely. This article reviews a surgeon's experience with the use of robotic surgery for liver resections. From March 2002 to March 2009, 70 robotic liver resections were performed at 2 different centers by a single surgeon. The surgical procedure and postoperative outcome data were reviewed retrospectively. Malignant tumors were indications for resections in 42 (60%) patients, whereas benign tumors were indications in 28 (40%) patients. The median age was 60 years (range, 21-84) and 57% of patients were female. Major liver resections (≥ 3 liver segments) were performed in 27 (38.5%) patients. There were 4 conversions to open surgery (5.7%). The median operative time for a major resection was 313 min (range, 220-480) and 198 min (range, 90-459) for minor resection. The median blood loss was 150 mL (range, 20-1,800) for minor resection and 300 mL (range, 100-2,000) for major resection. The mortality rate was 0%, and the overall rate of complications was 21%. Major morbidity occurred in 4 patients in the major hepatectomies group (14.8%) and in 4 patients in the minor hepatectomies group (9.3%). All complications were managed conservatively and none required reoperation. This preliminary experience shows that robotic surgery can be used safely for liver resections with a limited conversion rate, blood loss, and postoperative morbidity. Robotics offers a new technical option for minimally invasive liver surgery. Copyright © 2011 Mosby, Inc. All rights reserved.

  19. Robots in Elderly Care

    Directory of Open Access Journals (Sweden)

    Alessandro Vercelli

    2018-03-01

    Full Text Available Low birth rate and the long life expectancy represent an explosive mixture, resulting in the rapid aging of population. The costs of healthcare in the grey society are increasing dramatically, and soon there will be not enough resources and people for care. This context requires conceptually new elderly care solutions progressively reducing the percentages of the human-based care. Research on robot-based solutions for elderly care and active ageing aims to answer these needs. From a general perspective, robotics has the power to completely reshape the landscape of healthcare both in its structure and its operation. In fact, the long-term sustainability of healthcare systems could be addressed by automation powered by digital health technologies, such as artificial intelligence, 3D-printing or robotics. The latter could take over monotonous work from healthcare workers, which would allow them to focus more on patients and to have lesser workload. Robots might be used in elder care with several different aims. (i Robots may act as caregivers, i.e. assist the elderly, (ii they can provide remainders and instructions for activities of daily life and safety, and/or assist their carers in daily tasks; (iii they can help monitor their behaviour and health; and (iv provide companionship, including entertainment and hobbies, reminiscence and social contact. The use of Robots with human subjects/patients raise several sensitive questions. First of all, robots may represent information hubs, and can collect an incredible amount of data about the subjects and their environment. In fact, they record habits such as sleeping, exercising, third persons entering in the house, appointments. Communications may be continuously recorded. Moreover, by connecting with medical devices, they can store medical data. On one hand, this represents a very powerful tool to collect information about the single subject (precision medicine, about disease (thus eventually finding

  20. Application requirements for Robotic Nursing Assistants in hospital environments

    Science.gov (United States)

    Cremer, Sven; Doelling, Kris; Lundberg, Cody L.; McNair, Mike; Shin, Jeongsik; Popa, Dan

    2016-05-01

    In this paper we report on analysis toward identifying design requirements for an Adaptive Robotic Nursing Assistant (ARNA). Specifically, the paper focuses on application requirements for ARNA, envisioned as a mobile assistive robot that can navigate hospital environments to perform chores in roles such as patient sitter and patient walker. The role of a sitter is primarily related to patient observation from a distance, and fetching objects at the patient's request, while a walker provides physical assistance for ambulation and rehabilitation. The robot will be expected to not only understand nurse and patient intent but also close the decision loop by automating several routine tasks. As a result, the robot will be equipped with sensors such as distributed pressure sensitive skins, 3D range sensors, and so on. Modular sensor and actuator hardware configured in the form of several multi-degree-of-freedom manipulators, and a mobile base are expected to be deployed in reconfigurable platforms for physical assistance tasks. Furthermore, adaptive human-machine interfaces are expected to play a key role, as they directly impact the ability of robots to assist nurses in a dynamic and unstructured environment. This paper discusses required tasks for the ARNA robot, as well as sensors and software infrastructure to carry out those tasks in the aspects of technical resource availability, gaps, and needed experimental studies.

  1. Patient-Centered Robot-Aided Passive Neurorehabilitation Exercise Based on Safety-Motion Decision-Making Mechanism

    Directory of Open Access Journals (Sweden)

    Lizheng Pan

    2017-01-01

    Full Text Available Safety is one of the crucial issues for robot-aided neurorehabilitation exercise. When it comes to the passive rehabilitation training for stroke patients, the existing control strategies are usually just based on position control to carry out the training, and the patient is out of the controller. However, to some extent, the patient should be taken as a “cooperator” of the training activity, and the movement speed and range of the training movement should be dynamically regulated according to the internal or external state of the subject, just as what the therapist does in clinical therapy. This research presents a novel motion control strategy for patient-centered robot-aided passive neurorehabilitation exercise from the point of the safety. The safety-motion decision-making mechanism is developed to online observe and assess the physical state of training impaired-limb and motion performances and regulate the training parameters (motion speed and training rage, ensuring the safety of the supplied rehabilitation exercise. Meanwhile, position-based impedance control is employed to realize the trajectory tracking motion with interactive compliance. Functional experiments and clinical experiments are investigated with a healthy adult and four recruited stroke patients, respectively. The two types of experimental results demonstrate that the suggested control strategy not only serves with safety-motion training but also presents rehabilitation efficacy.

  2. Prosthetic reconstruction with an obturator using swing-lock attachment for a patient underwent maxillectomy: A clinical report

    Science.gov (United States)

    2016-01-01

    Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth. PMID:27826392

  3. Use of the new da Vinci Xi® during robotic rectal resection for cancer: a pilot matched-case comparison with the da Vinci Si®.

    Science.gov (United States)

    Morelli, Luca; Guadagni, Simone; Di Franco, Gregorio; Palmeri, Matteo; Caprili, Giovanni; D'Isidoro, Cristiano; Cobuccio, Luigi; Marciano, Emanuele; Di Candio, Giulio; Mosca, Franco

    2017-03-01

    The aim of this study was to compare the short-term outcomes of robotic rectal resection with total mesorectal excision (TME) for rectal cancer, with the use of the new da Vinci Xi® (Xi-RobTME group) and the da Vinci Si® (Si-RobTME group). Ten patients with histologically confirmed rectal cancer underwent robot-assisted TME with the use of the new da Vinci Xi. The outcomes of Xi-RobTME group were compared with a Si-RobTME group selected using a case-matched methodology. Overall operative times and mean hospital stays were shorter in the Xi-RobTME group. Surgeries were fully robotic with a complete take-down of the splenic flexure in all Xi-RobTME cases, while only four cases of the Si-RobTME group were fully robotic, with two cases of complete take-down of the splenic flexure. The new da Vinci Xi could offer some advantages with respect to the da Vinci Si in rectal resection for cancer. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Cultural Robotics: The Culture of Robotics and Robotics in Culture

    OpenAIRE

    Hooman Samani; Elham Saadatian; Natalie Pang; Doros Polydorou; Owen Noel Newton Fernando; Ryohei Nakatsu; Jeffrey Tzu Kwan Valino Koh

    2013-01-01

    In this paper, we have investigated the concept of “Cultural Robotics” with regard to the evolution of social into cultural robots in the 21st Century. By defining the concept of culture, the potential development of a culture between humans and robots is explored. Based on the cultural values of the robotics developers, and the learning ability of current robots, cultural attributes in this regard are in the process of being formed, which would define the new concept of cultural robotics. Ac...

  5. Effect of Robotic-Assisted vs Conventional Laparoscopic Surgery on Risk of Conversion to Open Laparotomy Among Patients Undergoing Resection for Rectal Cancer

    Science.gov (United States)

    Pigazzi, Alessio; Marshall, Helen; Croft, Julie; Corrigan, Neil; Copeland, Joanne; Quirke, Phil; West, Nick; Rautio, Tero; Thomassen, Niels; Tilney, Henry; Gudgeon, Mark; Bianchi, Paolo Pietro; Edlin, Richard; Hulme, Claire; Brown, Julia

    2017-01-01

    Importance Robotic rectal cancer surgery is gaining popularity, but limited data are available regarding safety and efficacy. Objective To compare robotic-assisted vs conventional laparoscopic surgery for risk of conversion to open laparotomy among patients undergoing resection for rectal cancer. Design, Setting, and Participants Randomized clinical trial comparing robotic-assisted vs conventional laparoscopic surgery among 471 patients with rectal adenocarcinoma suitable for curative resection conducted at 29 sites across 10 countries, including 40 surgeons. Recruitment of patients was from January 7, 2011, to September 30, 2014, follow-up was conducted at 30 days and 6 months, and final follow-up was on June 16, 2015. Interventions Patients were randomized to robotic-assisted (n = 237) or conventional (n = 234) laparoscopic rectal cancer resection, performed by either high (upper rectum) or low (total rectum) anterior resection or abdominoperineal resection (rectum and perineum). Main Outcomes and Measures The primary outcome was conversion to open laparotomy. Secondary end points included intraoperative and postoperative complications, circumferential resection margin positivity (CRM+) and other pathological outcomes, quality of life (36-Item Short Form Survey and 20-item Multidimensional Fatigue Inventory), bladder and sexual dysfunction (International Prostate Symptom Score, International Index of Erectile Function, and Female Sexual Function Index), and oncological outcomes. Results Among 471 randomized patients (mean [SD] age, 64.9 [11.0] years; 320 [67.9%] men), 466 (98.9%) completed the study. The overall rate of conversion to open laparotomy was 10.1%: 19 of 236 patients (8.1%) in the robotic-assisted laparoscopic group and 28 of 230 patients (12.2%) in the conventional laparoscopic group (unadjusted risk difference = 4.1% [95% CI, −1.4% to 9.6%]; adjusted odds ratio = 0.61 [95% CI, 0.31 to 1.21]; P = .16). The overall CRM+ rate was

  6. Trust me, I am Robot!

    DEFF Research Database (Denmark)

    Stoyanova, Angelina; Drefeld, Jonas; Tanev, Stoyan

    of the emerging trust relationship is a key component of the use value of the robotic system and of the value proposition of the robotic system producers. The study is based on a qualitative research approach combining the phenomenological research paradigm with a grounded theory building approach based......The aim of this paper is to discuss some of the issues regarding the emergence of trust within the context of the interaction between human patients and medical rehabilitation technology based on robot system solutions. The starting assumption of the analysis is that the articulation...

  7. Cognitive training for technical and non-technical skills in robotic surgery: a randomised controlled trial.

    Science.gov (United States)

    Raison, Nicholas; Ahmed, Kamran; Abe, Takashige; Brunckhorst, Oliver; Novara, Giacomo; Buffi, Nicolò; McIlhenny, Craig; van der Poel, Henk; van Hemelrijck, Mieke; Gavazzi, Andrea; Dasgupta, Prokar

    2018-05-07

    To investigate the effectiveness of motor imagery (MI) for technical skill and non-technical skill (NTS) training in minimally invasive surgery (MIS). A single-blind, parallel-group randomised controlled trial was conducted at the Vattikuti Institute of Robotic Surgery, King's College London. Novice surgeons were recruited by open invitation in 2015. After basic robotic skills training, participants underwent simple randomisation to either MI training or standard training. All participants completed a robotic urethrovesical anastomosis task within a simulated operating room. In addition to the technical task, participants were required to manage three scripted NTS scenarios. Assessment was performed by five blinded expert surgeons and a NTS expert using validated tools for evaluating technical skills [Global Evaluative Assessment of Robotic Skills (GEARS)] and NTS [Non-Technical Skills for Surgeons (NOTSS)]. Quality of MI was assessed using a revised Movement Imagery Questionnaire (MIQ). In all, 33 participants underwent MI training and 29 underwent standard training. Interrater reliability was high, Krippendorff's α = 0.85. After MI training, the mean (sd) GEARS score was significantly higher than after standard training, at 13.1 (3.25) vs 11.4 (2.97) (P = 0.03). There was no difference in mean NOTSS scores, at 25.8 vs 26.4 (P = 0.77). MI training was successful with significantly higher imagery scores than standard training (mean MIQ score 5.1 vs 4.5, P = 0.04). Motor imagery is an effective training tool for improving technical skill in MIS even in novice participants. No beneficial effect for NTS was found. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  8. A pet-type robot AIBO-assisted therapy as a day care program for chronic schizophrenia patients: A pilot study

    Directory of Open Access Journals (Sweden)

    Shin Narita

    2016-07-01

    Full Text Available Background AAT (Animal-assisted therapy was developed to promote human social and emotional functioning as a day care program for psychiatric patients. Aims In this study, we performed AAT using a pet-type robot, AIBO for schizophrenic patients. Methods After obtaining informed consent, we performed the AIBO-assisted therapy for three schizophrenic (ICD-10, F20.x2 patients (male: 1, female: 2 whose medication did not change over the 8 weeks study period in a ward. Results It was found that the AAT using AIBO may be useful for the patients with negative and general psychopathological symptoms such as “Anxiety” and “Uncooperativeness”. Conclusion We make use of this result, and we want to develop the AAT program using a pet-type robot, AIBO which may be suitable for Japanese psychiatric patients.

  9. The circumferential resection margins status: A comparison of robotic, laparoscopic and open total mesorectal excision for mid and low rectal cancer.

    Science.gov (United States)

    de Jesus, J P; Valadão, M; de Castro Araujo, R O; Cesar, D; Linhares, E; Iglesias, A C

    2016-06-01

    Minimally invasive surgery for rectal cancer (RC) is now widely performed via the laparoscopic approach, but robotic-assisted surgery may overcome some limitations of laparoscopy in RC treatment. We compared the rate of positive circumferential margins between robotic, laparoscopic and open total mesorectal excision (TME) for RC in our institution. Mid and low rectal adenocarcinoma patients consecutively submitted to robotic surgery were compared to laparoscopic and open approach. From our prospective database, 59 patients underwent robotic-assisted rectal surgery from 2012 to 2015 (RTME group) were compared to our historical control group comprising 200 open TME (OTME group) and 41 laparoscopic TME (LTME group) approaches from July 2008 to February 2012. Primary endpoint was to compare the rate of involved circumferential resection margins (CRM) and the mean CRM between the three groups. Secondary endpoint was to compare the mean number of resected lymph nodes between the three groups. CRM involvement was demonstrated in 20 patients (15.5%) in OTME, 4 (16%) in LTME and 9 (16.4%) in the RTME (p = 0.988). The mean CRM in OTME, LTME and RTME were respectively 0.6 cm (0-2.7), 0.7 cm (0-2.0) and 0.6 cm (0-2.0) (p = 0.960). Overall mean LN harvest was 14 (0-56); 16 (0-52) in OTME, 13 (1-56) in LTME and 10 (0-45) in RTME (p = 0.156). Our results suggest that robotic TME has the same oncological short-term results when compared to the open and laparoscopic technique, and it could be safely offered for the treatment of mid and low rectal cancer. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Robot Actors, Robot Dramaturgies

    DEFF Research Database (Denmark)

    Jochum, Elizabeth

    This paper considers the use of tele-operated robots in live performance. Robots and performance have long been linked, from the working androids and automata staged in popular exhibitions during the nineteenth century and the robots featured at Cybernetic Serendipity (1968) and the World Expo...

  11. Robotic technology in surgery: current status in 2008.

    Science.gov (United States)

    Murphy, Declan G; Hall, Rohan; Tong, Raymond; Goel, Rajiv; Costello, Anthony J

    2008-12-01

    There is increasing patient and surgeon interest in robotic-assisted surgery, particularly with the proliferation of da Vinci surgical systems (Intuitive Surgical, Sunnyvale, CA, USA) throughout the world. There is much debate over the usefulness and cost-effectiveness of these systems. The currently available robotic surgical technology is described. Published data relating to the da Vinci system are reviewed and the current status of surgical robotics within Australia and New Zealand is assessed. The first da Vinci system in Australia and New Zealand was installed in 2003. Four systems had been installed by 2006 and seven systems are currently in use. Most of these are based in private hospitals. Technical advantages of this system include 3-D vision, enhanced dexterity and improved ergonomics when compared with standard laparoscopic surgery. Most procedures currently carried out are urological, with cardiac, gynaecological and general surgeons also using this system. The number of patients undergoing robotic-assisted surgery in Australia and New Zealand has increased fivefold in the past 4 years. The most common procedure carried out is robotic-assisted laparoscopic radical prostatectomy. Published data suggest that robotic-assisted surgery is feasible and safe although the installation and recurring costs remain high. There is increasing acceptance of robotic-assisted surgery, especially for urological procedures. The da Vinci surgical system is becoming more widely available in Australia and New Zealand. Other surgical specialties will probably use this technology. Significant costs are associated with robotic technology and it is not yet widely available to public patients.

  12. Anatomical location of metastatic lymph nodes: an indispensable prognostic factor for gastric cancer patients who underwent curative resection.

    Science.gov (United States)

    Zhao, Bochao; Zhang, Jingting; Zhang, Jiale; Chen, Xiuxiu; Chen, Junqing; Wang, Zhenning; Xu, Huimian; Huang, Baojun

    2018-02-01

    Although the numeric-based lymph node (LN) staging was widely used in the worldwide, it did not represent the anatomical location of metastatic lymph nodes (MLNs) and not reflect extent of LN dissection. Therefore, in the present study, we investigated whether the anatomical location of MLNs was still necessary to evaluate the prognosis of node-positive gastric cancer (GC) patients. We reviewed 1451 GC patients who underwent radical gastrectomy in our institution between January 1986 and January 2008. All patients were reclassified into several groups according to the anatomical location of MLNs and the number of MLNs. The prognostic differences between different patient groups were compared and clinicopathologic features were analyzed. In the present study, both anatomical location of MLNs and the number of MLNs were identified as the independent prognostic factors (p location of MLNs was considered (p location of MLNs had no significant effect on the prognosis of these patients, the higher number of MLNs in the extraperigastric area was correlated with the unfavorable prognosis (p location of MLNs was an important factor influencing the prognostic outcome of GC patients. To provide more accurate prognostic information for GC patients, the anatomical location of MLNs should not be ignored.

  13. Robotic parathyroidectomy.

    Science.gov (United States)

    Okoh, Alexis Kofi; Sound, Sara; Berber, Eren

    2015-09-01

    Robotic parathyroidectomy has recently been described. Although the procedure eliminates the neck scar, it is technically more demanding than the conventional approaches. This report is a review of the patients' selection criteria, technique, and outcomes. © 2015 Wiley Periodicals, Inc.

  14. Virtual Sensors for Advanced Controllers in Rehabilitation Robotics.

    Science.gov (United States)

    Mancisidor, Aitziber; Zubizarreta, Asier; Cabanes, Itziar; Portillo, Eva; Jung, Je Hyung

    2018-03-05

    In order to properly control rehabilitation robotic devices, the measurement of interaction force and motion between patient and robot is an essential part. Usually, however, this is a complex task that requires the use of accurate sensors which increase the cost and the complexity of the robotic device. In this work, we address the development of virtual sensors that can be used as an alternative of actual force and motion sensors for the Universal Haptic Pantograph (UHP) rehabilitation robot for upper limbs training. These virtual sensors estimate the force and motion at the contact point where the patient interacts with the robot using the mathematical model of the robotic device and measurement through low cost position sensors. To demonstrate the performance of the proposed virtual sensors, they have been implemented in an advanced position/force controller of the UHP rehabilitation robot and experimentally evaluated. The experimental results reveal that the controller based on the virtual sensors has similar performance to the one using direct measurement (less than 0.005 m and 1.5 N difference in mean error). Hence, the developed virtual sensors to estimate interaction force and motion can be adopted to replace actual precise but normally high-priced sensors which are fundamental components for advanced control of rehabilitation robotic devices.

  15. A simulation and training environment for robotic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Schlaefer, Alexander [University of Luebeck, Institute for Robotics and Cognitive Systems, Luebeck (Germany); Stanford University, Department of Radiation Oncology, Stanford, CA (United States); Gill, Jakub; Schweikard, Achim [University of Luebeck, Institute for Robotics and Cognitive Systems, Luebeck (Germany)

    2008-09-15

    To provide a software environment for simulation of robotic radiosurgery, particularly to study the effective robot workspace with respect to the treatment plan quality, and to illustrate the concepts of robotic radiosurgery. A simulation environment for a robotic radiosurgery system was developed using Java and Java3D. The kinematics and the beam characteristics were modeled and linked to a treatment planning module. Simulations of different robot workspace parameters for two example radiosurgical patient cases were performed using the novel software tool. The first case was an intracranial lesion near the left inner ear, the second case was a spinal lesion. The planning parameters for both cases were visualized with the novel simulation environment. An incremental extension of the robot workspace had limited effect for the intracranial case, where the original workspace already covered the left side of the patient. For the spinal case, a larger workspace resulted in a noticeable improvement in plan quality and a large portion of the beams being delivered from the extended workspace. The new software environment is useful to simulate and analyze parameters and configurations for robotic radiosurgery. An enlarged robot workspace may result in improved plan quality depending on the location of the target region. (orig.)

  16. A simulation and training environment for robotic radiosurgery

    International Nuclear Information System (INIS)

    Schlaefer, Alexander; Gill, Jakub; Schweikard, Achim

    2008-01-01

    To provide a software environment for simulation of robotic radiosurgery, particularly to study the effective robot workspace with respect to the treatment plan quality, and to illustrate the concepts of robotic radiosurgery. A simulation environment for a robotic radiosurgery system was developed using Java and Java3D. The kinematics and the beam characteristics were modeled and linked to a treatment planning module. Simulations of different robot workspace parameters for two example radiosurgical patient cases were performed using the novel software tool. The first case was an intracranial lesion near the left inner ear, the second case was a spinal lesion. The planning parameters for both cases were visualized with the novel simulation environment. An incremental extension of the robot workspace had limited effect for the intracranial case, where the original workspace already covered the left side of the patient. For the spinal case, a larger workspace resulted in a noticeable improvement in plan quality and a large portion of the beams being delivered from the extended workspace. The new software environment is useful to simulate and analyze parameters and configurations for robotic radiosurgery. An enlarged robot workspace may result in improved plan quality depending on the location of the target region. (orig.)

  17. Virtual Sensors for Advanced Controllers in Rehabilitation Robotics

    Directory of Open Access Journals (Sweden)

    Aitziber Mancisidor

    2018-03-01

    Full Text Available In order to properly control rehabilitation robotic devices, the measurement of interaction force and motion between patient and robot is an essential part. Usually, however, this is a complex task that requires the use of accurate sensors which increase the cost and the complexity of the robotic device. In this work, we address the development of virtual sensors that can be used as an alternative of actual force and motion sensors for the Universal Haptic Pantograph (UHP rehabilitation robot for upper limbs training. These virtual sensors estimate the force and motion at the contact point where the patient interacts with the robot using the mathematical model of the robotic device and measurement through low cost position sensors. To demonstrate the performance of the proposed virtual sensors, they have been implemented in an advanced position/force controller of the UHP rehabilitation robot and experimentally evaluated. The experimental results reveal that the controller based on the virtual sensors has similar performance to the one using direct measurement (less than 0.005 m and 1.5 N difference in mean error. Hence, the developed virtual sensors to estimate interaction force and motion can be adopted to replace actual precise but normally high-priced sensors which are fundamental components for advanced control of rehabilitation robotic devices.

  18. The first step in using a robot in brain injury rehabilitation: patients' and health-care professionals' perspective.

    Science.gov (United States)

    Boman, Inga-Lill; Bartfai, Aniko

    2015-01-01

    To evaluate the usability of a mobile telepresence robot (MTR) in a hospital training apartment (HTA). The MTR was manoeuvred remotely and was used for communication when assessing independent living skills, and for security monitoring of cognitively impaired patients. Occupational therapists (OTs) and nurses received training in how to use the MTR. The nurses completed a questionnaire regarding their expectations of using the MTR. OTs and patients staying in the HTA were interviewed about their experiences of the MTR. Interviews and questionnaires were analysed qualitatively. The HTA patients were very satisfied with the MTR. The OTs and nurses reported generally positive experiences. The OT's found that assessment via the MTR was more neutral than being physically present. However, the use of the MTR implied considerable difficulties for health-care professionals. The main obstacle for the nurses was the need for fast and easy access in emergency situations while protecting the patients' integrity. The results indicate that the MTR could be a useful tool to support daily living skills and safety monitoring of HTA patients. However, when designing technology for multiple users, such as health-care professionals, the needs of all users, their routines and support services involved, should also be considered. Implications for Rehabilitation A mobile telepresence robot (MTR) can be a useful tool for assessments and communication in rehabilitation. The design of the robot has to allow easy use by remote users, particularly in emergency situations. When designing MTRs the needs of ALL users have to be taken into consideration.

  19. Transcranial doppler sonography in two patients who underwent decompressive craniectomy for traumatic brain swelling: report of two cases

    Directory of Open Access Journals (Sweden)

    Bor-Seng-Shu Edson

    2004-01-01

    Full Text Available The role of decompressive craniectomy in the treatment of severe posttraumatic cerebral swelling remains quite a controversial issue. To the best of our knowledge, there is no study demonstrating the effect of decompressive craniectomy on cerebral blood flow (CBF velocity by means of transcranial Doppler sonography (TCD. We present two patients who developed traumatic brain swelling and uncontrollable intracranial hypertension with coma and signs of transtentorial herniation. One patient underwent bifrontal, while the second, unilateral, frontotemporoparietal decompressive craniectomy with dural expansion. In both patients, TCD examinations were performed immediately before and after surgery to study the cerebral hemodynamic changes related to the operations. Pre and postoperative TCD examinations demonstrated a significant increase in blood flow velocity in the intracranial arteries in both subjects. In conclusion, our cases suggest that decompressive craniectomy with dural expansion may result in elevation of CBF velocity in patients with massive brain swelling. The increase in CBF velocity appears to occur not only in the decompressed hemisphere, but also on the opposite side.

  20. Scenario-Based Assessment of User Needs for Point-of-Care Robots.

    Science.gov (United States)

    Lee, Hyeong Suk; Kim, Jeongeun

    2018-01-01

    This study aimed to derive specific user requirements and barriers in a real medical environment to define the essential elements and functions of two types of point-of-care (POC) robot: a telepresence robot as a tool for teleconsultation, and a bedside robot to provide emotional care for patients. An analysis of user requirements was conducted; user needs were gathered and identified, and detailed, realistic scenarios were created. The prototype robots were demonstrated in physical environments for envisioning and evaluation. In all, three nurses and three clinicians participated as evaluators to observe the demonstrations and evaluate the robot systems. The evaluators were given a brief explanation of each scene and the robots' functionality. Four major functions of the teleconsultation robot were defined and tested in the demonstration. In addition, four major functions of the bedside robot were evaluated. Among the desired functions for a teleconsultation robot, medical information delivery and communication had high priority. For a bedside robot, patient support, patient monitoring, and healthcare provider support were the desired functions. The evaluators reported that the teleconsultation robot can increase support from and access to specialists and resources. They mentioned that the bedside robot can improve the quality of hospital life. Problems identified in the demonstration were those of space conflict, communication errors, and safety issues. Incorporating this technology into healthcare services will enhance communication and teamwork skills across distances and thereby facilitate teamwork. However, repeated tests will be needed to evaluate and ensure improved performance.

  1. How to decide which infant can have robotic surgery? Just do the math.

    Science.gov (United States)

    Finkelstein, J B; Levy, A C; Silva, M V; Murray, L; Delaney, C; Casale, P

    2015-08-01

    In pediatric urology, robot-assisted surgery has overcome several impediments of conventional laparoscopy. However, workspace has a major impact on surgical performance. The limited space in an infant can significantly impede the mobility of robotic instruments. There is currently no consensus on which infant can undergo robotic intervention and no parameters to help make this decision, especially for those surgeons at the start of their learning curve. We sought to evaluate our experience with infants to create an objective standard to determine which patients may be most suitable for robotic surgery. We prospectively evaluated 45 infants (24 males, 21 females), aged 3-12 months old, who underwent a robotic intervention for either upper or lower urinary tract pathology. At the preoperative office visit the attending surgeon measured the distance between both anterior superior iliac spines (ASIS) as well as the puboxyphoid distance (PXD), regardless of whether the approach was for upper or lower tract disease. Patients' weights were also noted. During surgery, we recorded the number of robotic collisions as well as console time. All surgeries were performed utilizing the da Vinci Si Surgical System by a single surgeon. There were no differences in ASIS, PXD, collisions or console time when stratified by gender, age or weight. When arranging by upper or lower tract approach, there was no difference in the number of collisions. There was a strong inverse relationship between both ASIS distance and PXD and the number of collisions. Additionally, there was a strong correlation between the number of collisions and console time (Fig. 1). Using a cutoff of 13 cm for the ASIS, there were significantly fewer collisions in the >13 cm group as compared to the ≤13 cm group. This was also true for the PXD using a cutoff of 15 cm: there were significantly fewer collisions in the >15 cm group as compared to the ≤15 cm group. Safe proliferation of robotic technology in the

  2. The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients.

    Science.gov (United States)

    Serletis, Demitre; Bulacio, Juan; Bingaman, William; Najm, Imad; González-Martínez, Jorge

    2014-11-01

    Stereoelectroencephalography (SEEG) is a methodology that permits accurate 3D in vivo electroclinical recordings of epileptiform activity. Among other general indications for invasive intracranial electroencephalography (EEG) monitoring, its advantages include access to deep cortical structures, its ability to localize the epileptogenic zone when subdural grids have failed to do so, and its utility in the context of possible multifocal seizure onsets with the need for bihemispheric explorations. In this context, the authors present a brief historical overview of the technique and report on their experience with 2 SEEG techniques (conventional Leksell frame-based stereotaxy and frameless stereotaxy under robotic guidance) for the purpose of invasively monitoring difficult-to-localize refractory focal epilepsy. Over a period of 4 years, the authors prospectively identified 200 patients with refractory epilepsy who collectively underwent 2663 tailored SEEG electrode implantations for invasive intracranial EEG monitoring and extraoperative mapping. The first 122 patients underwent conventional Leksell frame-based SEEG electrode placement; the remaining 78 patients underwent frameless stereotaxy under robotic guidance, following acquisition of a stereotactic ROSA robotic device at the authors' institution. Electrodes were placed according to a preimplantation hypothesis of the presumed epileptogenic zone, based on a standardized preoperative workup including video-EEG monitoring, MRI, PET, ictal SPECT, and neuropsychological assessment. Demographic features, seizure semiology, number and location of implanted SEEG electrodes, and location of the epileptogenic zone were recorded and analyzed for all patients. For patients undergoing subsequent craniotomy for resection, the type of resection and procedure-related complications were prospectively recorded. These results were analyzed and correlated with pathological diagnosis and postoperative seizure outcomes. The

  3. Clinical and echocardiographic findings of patients with suspected acute pulmonary thromboembolism who underwent computed tomography pulmonary angiography

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2016-01-01

    Full Text Available Background: The aim of the study was to determine the correlation between clinical and echocardiographic findings and risk factors of patients with suspected acute pulmonary thromboembolism (PTE who underwent computed tomography pulmonary angiography (CTPA. Materials and Methods: In this cross-sectional study, 310 hospitalized patients aged >18 years with high clinical suspicion of PTE referred to imaging center of our hospital from different wards for CTPA were enrolled. The frequency of different clinical presentations, risk factors, items of Wells' criteria, and echocardiographic findings was compared in patients with and without PTE, which have been diagnosed according to the CTPA results. Results: PTE was diagnosed in 53 (17.1% of patients with suspected PTE. From clinical manifestations, tachypnea, pleuritic chest pain, and edema of lower extremities were significantly more frequent among patients with PTE (P < 0.05. Major surgery was the risk factor which was significantly more prevalent among patients with PTE (P < 0.05. Frequency of all criteria of Wells' criteria, except hemoptysis, was significantly higher in patients with PTE (P < 0.05. The frequency of all studied echocardiographic variables was significantly higher in patients with PTE (P < 0.05. Conclusion: It is suggested that we could use the results of this study for utilizing the diagnostic process of PTE in patients with highly clinical suspicion of PTE and providing more validated decision. Using the results of this study, we could identify high-risk patients and made appropriate risk assessment for better management of patients with suspected PTE as well as reduce the rate of unnecessary CTPA and its related adverse consequences.

  4. Work-rate-guided exercise testing in patients with incomplete spinal cord injury using a robotics-assisted tilt-table.

    Science.gov (United States)

    Laubacher, Marco; Perret, Claudio; Hunt, Kenneth J

    2015-01-01

    Robotics-assisted tilt-table (RTT) technology allows neurological rehabilitation therapy to be started early thus alleviating some secondary complications of prolonged bed rest. This study assessed the feasibility of a novel work-rate-guided RTT approach for cardiopulmonary training and assessment in patients with incomplete spinal cord injury (iSCI). Three representative subjects with iSCI at three distinct stages of primary rehabilitation completed an incremental exercise test (IET) and a constant load test (CLT) on a RTT augmented with integrated leg-force and position measurement and visual work rate feedback. Feasibility assessment focused on: (i) implementation, (ii) limited efficacy testing, (iii) acceptability. (i) All subjects were able follow the work rate target profile by adapting their volitional leg effort. (ii) During the IETs, peak oxygen uptake above rest was 304, 467 and 1378 ml/min and peak heart rate (HR) was 46, 32 and 65 beats/min above rest (subjects A, B and C, respectively). During the CLTs, steady-state oxygen uptake increased by 42%, 38% and 162% and HR by 12%, 20% and 29%. (iii) All exercise tests were tolerated well. The novel work-rate guided RTT intervention is deemed feasible for cardiopulmonary training and assessment in patients with iSCI: substantial cardiopulmonary responses were observed and the approach was found to be tolerable and implementable. Implications for Rehabilitation Work-rate guided robotics-assisted tilt-table technology is deemed feasible for cardiopulmonary assessment and training in patients with incomplete spinal cord injury. Robotics-assisted tilt-tables might be a good way to start with an active rehabilitation as early as possible after a spinal cord injury. During training with robotics-assisted devices the active participation of the patients is crucial to strain the cardiopulmonary system and hence gain from the training.

  5. Spinal plasticity in robot-mediated therapy for the lower limbs

    DEFF Research Database (Denmark)

    Stevenson, Andrew James Thomas; Mrachacz-Kersting, Natalie; van Asseldonk, Edwin

    2015-01-01

    of neural changes in the spinal cord. Here, we review the recent literature on spinal plasticity induced by robotic-based training in humans and propose recommendations for the measurement of spinal plasticity using robotic devices. Evidence for spinal plasticity in humans following robotic training...... but are not part of robotic devices used for training purposes. A further development of robotic devices that include the technology to elicit stretch reflexes would allow for the spinal circuitry to be routinely tested as a part of the training and evaluation protocols.......Robot-mediated therapy can help improve walking ability in patients following injuries to the central nervous system. However, the efficacy of this treatment varies between patients, and evidence for the mechanisms underlying functional improvements in humans is poor, particularly in terms...

  6. Treatment Availability Influences Physicians' Portrayal of Robotic Surgery During Clinical Appointments.

    Science.gov (United States)

    Scherr, Karen A; Fagerlin, Angela; Wei, John T; Williamson, Lillie D; Ubel, Peter A

    2017-01-01

    In order to empower patients as decision makers, physicians must educate them about their treatment options in a factual, nonbiased manner. We propose that site-specific availability of treatment options may be a novel source of bias, whereby physicians describe treatments more positively when they are available. We performed a content analysis of physicians' descriptions of robotic prostatectomy within 252 appointments at four Veterans Affairs medical centers where robotic surgery was either available or unavailable. We coded how physicians portrayed robotic versus open prostatectomy across specific clinical categories and in the appointment overall. We found that physicians were more likely to describe robotic prostatectomy as superior when it was available [F(1, 42) = 8.65, p = .005]. We also provide initial qualitative evidence that physicians may be shaping their descriptions of robotic prostatectomy in an effort to manage patients' emotions and demand for the robotic technology. To our knowledge, this is the first study to provide empirical evidence that treatment availability influences how physicians describe the advantages and disadvantages of treatment alternatives to patients during clinical encounters, which has important practical implications for patient empowerment and patient satisfaction.

  7. Robot-assisted gait training versus treadmill training in patients with Parkinson's disease: a kinematic evaluation with gait profile score.

    Science.gov (United States)

    Galli, M; Cimolin, V; De Pandis, M F; Le Pera, D; Sova, I; Albertini, G; Stocchi, F; Franceschini, M

    2016-01-01

    The purpose of this study was to quantitatively compare the effects, on walking performance, of end-effector robotic rehabilitation locomotor training versus intensive training with a treadmill in Parkinson's disease (PD). Fifty patients with PD were randomly divided into two groups: 25 were assigned to the robot-assisted therapy group (RG) and 25 to the intensive treadmill therapy group (IG). They were evaluated with clinical examination and 3D quantitative gait analysis [gait profile score (GPS) and its constituent gait variable scores (GVSs) were calculated from gait analysis data] at the beginning (T0) and at the end (T1) of the treatment. In the RG no differences were found in the GPS, but there were significant improvements in some GVSs (Pelvic Obl and Hip Ab-Add). The IG showed no statistically significant changes in either GPS or GVSs. The end-effector robotic rehabilitation locomotor training improved gait kinematics and seems to be effective for rehabilitation in patients with mild PD.

  8. Comparative analysis of pain in patients who underwent total knee replacement regarding the tourniquet pressure

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leão

    Full Text Available ABSTRACT OBJECTIVES: To evaluate through the visual analog scale (VAS the pain in patients undergoing total knee replacement (TKR with different pressures of the pneumatic tourniquet. METHODS: An observational, randomized, descriptive study on an analytical basis, with 60 patients who underwent TKR, divided into two groups, which were matched: a group where TKR was performed with tourniquet pressures of 350 mmHg (standard and the other with systolic blood pressure plus 100 mmHg (P + 100. These patients had their pain assessed by VAS at 48 h, and at the 5th and 15th days after procedure. Secondarily, the following were also measured: range of motion (ROM, complications, and blood drainage volume in each group; the data were subjected to statistical analysis. RESULTS: After data analysis, there was no statistical difference regarding the incidence of complications (p = 0.612, ROM (p = 0.202, bleeding after 24 and 48 h (p = 0.432 and p = 0.254 or in relation to VAS. No correlation was observed between time of ischemia compared to VAS and bleeding. CONCLUSIONS: The use of the pneumatic tourniquet pressure at 350 mmHg or systolic blood pressure plus 100 mmHg did not influence the pain, blood loss, ROM, and complications. Therefore the pressures at these levels are safe and do not change the surgery outcomes; the time of ischemia must be closely observed to avoid major complications.

  9. Patient Perceptions of Open, Laparoscopic, and Robotic Gynecological Surgeries

    Directory of Open Access Journals (Sweden)

    Mohamad Irani

    2016-01-01

    Full Text Available Objective. To investigate patient knowledge and attitudes toward surgical approaches in gynecology. Design. An anonymous Institutional Review Board (IRB approved questionnaire survey. Patients/Setting. A total of 219 women seeking obstetrical and gynecological care in two offices affiliated with an academic medical center. Results. Thirty-four percent of the participants did not understand the difference between open and laparoscopic surgeries. 56% of the participants knew that laparoscopy is a better surgical approach for patients than open abdominal surgeries, while 37% thought that laparoscopy requires the surgeon to have a higher technical skill. 46% of the participants do not understand the difference between laparoscopic and robotic procedures. 67.5% of the participants did not know that the surgeon moves the robot’s arms to perform the surgery. Higher educational level and/or history of previous abdominal surgeries were associated with the highest rates of answering all the questions correctly (p<0.05, after controlling for age and race. Conclusions. A substantial percentage of patients do not understand the difference between various surgical approaches. Health care providers should not assume that their patients have an adequate understanding of their surgical options and accordingly should educate them about those options so they can make truly informed decisions.

  10. Is Ethics of Robotics about Robots? Philosophy of Robotics Beyond Realism and Individualilsm.

    NARCIS (Netherlands)

    Coeckelbergh, Mark

    2011-01-01

    If we are doing ethics of robotics, what exactly is the object of our inquiry? This paper challenges 'individualist' robot ontology and 'individualist' social philosophy of robots. It is argued that ethics of robotics should not study and evaluate robotics exclusively in terms of individual

  11. Robot-assisted laparoscopic dismembered pyeloplasty for ureteropelvic junction obstruction: a multi-institutional experience.

    Science.gov (United States)

    Sivaraman, Ananthakrishnan; Leveillee, Raymond J; Patel, Manoj B; Chauhan, Sanket; Bracho, Jorge E; Moore, Charles R; Coelho, Rafael F; Palmer, Kenneth J; Schatloff, Oscar; Bird, Vincent G; Munver, Ravi; Patel, Vipul R

    2012-02-01

    To report a 6-year multi-institutional experience and outcomes with robot-assisted laparoscopic pyeloplasty (RLP) for the repair of ureteropelvic junction obstruction (UPJO). Between June 2002 and October 2008, 168 adult patients from 3 institutions underwent RLP for UPJO. A retrospective analysis of prospectively collected data were performed after institutional review board approval. Diagnosis was by intravenous urogram or computed tomography scan and diuretic renogram. All patients underwent RLP through a 4-port laparoscopic technique. Demographic, preoperative, operative, and postoperative endpoints for primary and secondary repair of UPJO were measured. Success was defined as a T½ of <20 minutes on diuretic renogram and symptom resolution. Pain resolution was assessed by subjective patient reports. Of 168 patients, 147 (87.5%) had primary repairs and 21 (12.5%) had secondary repairs. Of the secondary repairs, 57% had a crossing vessel etiology. Mean operative time was 134.9 minutes, estimated blood loss was 49 mL, and length of stay was 1.5 days. Mean follow-up was 39 months. Overall, 97.6% of patients had a successful outcome, with a 6.6% overall complication rate. To our knowledge, this review represents the largest multi-institutional experience of RLP with intermediate-term follow-up. RLP is a safe, efficacious, and viable option for either primary or secondary repair of UPJO with reproducible outcomes, a high success rate, and a low incidence of complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Review of emerging surgical robotic technology.

    Science.gov (United States)

    Peters, Brian S; Armijo, Priscila R; Krause, Crystal; Choudhury, Songita A; Oleynikov, Dmitry

    2018-04-01

    The use of laparoscopic and robotic procedures has increased in general surgery. Minimally invasive robotic surgery has made tremendous progress in a relatively short period of time, realizing improvements for both the patient and surgeon. This has led to an increase in the use and development of robotic devices and platforms for general surgery. The purpose of this review is to explore current and emerging surgical robotic technologies in a growing and dynamic environment of research and development. This review explores medical and surgical robotic endoscopic surgery and peripheral technologies currently available or in development. The devices discussed here are specific to general surgery, including laparoscopy, colonoscopy, esophagogastroduodenoscopy, and thoracoscopy. Benefits and limitations of each technology were identified and applicable future directions were described. A number of FDA-approved devices and platforms for robotic surgery were reviewed, including the da Vinci Surgical System, Sensei X Robotic Catheter System, FreeHand 1.2, invendoscopy E200 system, Flex® Robotic System, Senhance, ARES, the Single-Port Instrument Delivery Extended Research (SPIDER), and the NeoGuide Colonoscope. Additionally, platforms were reviewed which have not yet obtained FDA approval including MiroSurge, ViaCath System, SPORT™ Surgical System, SurgiBot, Versius Robotic System, Master and Slave Transluminal Endoscopic Robot, Verb Surgical, Miniature In Vivo Robot, and the Einstein Surgical Robot. The use and demand for robotic medical and surgical platforms is increasing and new technologies are continually being developed. New technologies are increasingly implemented to improve on the capabilities of previously established systems. Future studies are needed to further evaluate the strengths and weaknesses of each robotic surgical device and platform in the operating suite.

  13. Exploratorium: Robots.

    Science.gov (United States)

    Brand, Judith, Ed.

    2002-01-01

    This issue of Exploratorium Magazine focuses on the topic robotics. It explains how to make a vibrating robotic bug and features articles on robots. Contents include: (1) "Where Robot Mice and Robot Men Run Round in Robot Towns" (Ray Bradbury); (2) "Robots at Work" (Jake Widman); (3) "Make a Vibrating Robotic Bug" (Modesto Tamez); (4) "The Robot…

  14. Perioperative outcomes of video- and robot-assisted segmentectomies.

    Science.gov (United States)

    Rinieri, Philippe; Peillon, Christophe; Salaün, Mathieu; Mahieu, Julien; Bubenheim, Michael; Baste, Jean-Marc

    2016-02-01

    Video-assisted thoracic surgery appears to be technically difficult for segmentectomy. Conversely, robotic surgery could facilitate the performance of segmentectomy. The aim of this study was to compare the early results of video- and robot-assisted segmentectomies. Data were collected prospectively on videothoracoscopy from 2010 and on robotic procedures from 2013. Fifty-one patients who were candidates for minimally invasive segmentectomy were included in the study. Perioperative outcomes of video-assisted and robotic segmentectomies were compared. The minimally invasive segmentectomies included 32 video- and 16 robot-assisted procedures; 3 segmentectomies (2 video-assisted and 1 robot-assisted) were converted to lobectomies. Four conversions to thoracotomy were necessary for anatomical reason or arterial injury, with no uncontrolled bleeding in the robotic arm. There were 7 benign or infectious lesions, 9 pre-invasive lesions, 25 lung cancers, and 10 metastatic diseases. Patient characteristics, type of segment, conversion to thoracotomy, conversion to lobectomy, operative time, postoperative complications, chest tube duration, postoperative stay, and histology were similar in the video and robot groups. Estimated blood loss was significantly higher in the video group (100 vs. 50 mL, p = 0.028). The morbidity rate of minimally invasive segmentectomy was low. The short-term results of video-assisted and robot-assisted segmentectomies were similar, and more data are required to show any advantages between the two techniques. Long-term oncologic outcomes are necessary to evaluate these new surgical practices. © The Author(s) 2016.

  15. Cultural acceptance of robotic telestroke medicine among patients and healthcare providers in Saudi Arabia

    Science.gov (United States)

    Al-Khathaami, Ali M.; Alshahrani, Saeed M.; Kojan, Suleiman M.; Al-Jumah, Mohammed A.; Alamry, Ahmed A.; El-Metwally, Ashraf A.

    2015-01-01

    Objectives: To determine the degree of satisfaction and acceptance of stroke patients, their relatives, and healthcare providers toward using telestroke technology in Saudi Arabia. Methods: A cross-sectional study was conducted between October and December 2012 at King Abdulaziz Medical City, Ministry of National Guard Affairs, Riyadh, Saudi Arabia. The Remote Presence Robot (RPR), the RP-7i® (FDA- cleared) provided by InTouch Health was used in the study. Patients and their relatives were informed that the physician would appear through a screen on top of a robotic device, as part of their clinical care. Stroke patients admitted through the emergency department, and their relatives, as well as healthcare providers completed a self-administered satisfaction questionnaire following the telestroke consultation sessions. Results: Fifty participants completed the questionnaire. Most subjects agreed that the remote consultant interview was useful and that the audiovisual component of the intervention was of high quality; 98% agreed that they did not feel shy or embarrassed during the remote interview, were able to understand the instruction of the consultant, and recommended its use in stroke management. Furthermore, 92% agreed or strongly agreed that the use of this technology can efficiently replace the physical presence of a neurologist. Conclusion: Results suggest that the use of telestroke medicine is culturally acceptable among stroke patients and their families in Saudi Arabia and favorably received by healthcare providers. PMID:25630777

  16. The Impact of Training Residents on the Outcome of Robotic-Assisted Sacrocolpopexy

    Directory of Open Access Journals (Sweden)

    Mohamed A. Bedaiwy

    2012-01-01

    Full Text Available Objective. To evaluate the surgical outcomes of robotic-assisted sacrocolpopexy (RASCP before and after the incorporation of hands-on training for urology and gynecology residents. Study Design. Forty-one patients underwent RASCP between December 2008 and March 2010 with one surgeon. RASCP was performed in the context of surgical repair of complex pelvic organ prolapse and/or stress urinary incontinence. The first 20 cases (group I were performed exclusively by the attending surgeon. In the last 21 cases (group II, the urology resident performed a 50% or more of the RASCP while the gynecology resident performed the supracervical hysterectomy. The primary outcome measure was vaginal vault support at 24 weeks postoperatively based on pelvic organ prolapse quantification (POP-Q. Results. Mean ± SD operative time for the entire surgery including RASCP was 282.3±51.3 min and median EBL was 83.1±50.4 mL. Patient demographics and stage of disease did not differ between groups. Procedure time, PACU time, blood loss, and intraoperative complications were similar between groups. Follow-up POP-Q evaluations demonstrated significant correction of all points on vaginal examination for both groups (P<0.001. Conclusions. Incorporation of resident training during RASCP allows teaching of robotic surgery techniques in an effective manner without prolonging operative time or affecting the overall surgical outcome.

  17. Robotics in Lower-Limb Rehabilitation after Stroke.

    Science.gov (United States)

    Zhang, Xue; Yue, Zan; Wang, Jing

    2017-01-01

    With the increase in the elderly, stroke has become a common disease, often leading to motor dysfunction and even permanent disability. Lower-limb rehabilitation robots can help patients to carry out reasonable and effective training to improve the motor function of paralyzed extremity. In this paper, the developments of lower-limb rehabilitation robots in the past decades are reviewed. Specifically, we provide a classification, a comparison, and a design overview of the driving modes, training paradigm, and control strategy of the lower-limb rehabilitation robots in the reviewed literature. A brief review on the gait detection technology of lower-limb rehabilitation robots is also presented. Finally, we discuss the future directions of the lower-limb rehabilitation robots.

  18. Multi-institutional analysis of robotic partial nephrectomy for hilar versus nonhilar lesions in 446 consecutive cases.

    Science.gov (United States)

    Dulabon, Lori M; Kaouk, Jihad H; Haber, Georges-Pascal; Berkman, Douglas S; Rogers, Craig G; Petros, Firas; Bhayani, Sam B; Stifelman, Michael D

    2011-03-01

    Minimally invasive approaches to partial nephrectomy have been rapidly gaining popularity but require advanced laparoscopic surgical skills. Renal hilar tumors, due to their anatomic location, pose additional technical challenges to the operating surgeon. We compared the outcomes of robot-assisted partial nephrectomy (RPN) for hilar and nonhilar tumors in our large multicenter contemporary series of patients. We retrospectively reviewed prospectively collected data on 446 consecutive patients who underwent RPN by renal surgeons experienced in minimally invasive techniques at four academic institutions from June 2006 to March 2010. Patients were stratified into two groups: those with hilar lesions and those with nonhilar lesions. Patient demographics, operative outcomes, and postoperative outcomes, including oncologic outcomes, were recorded. Forty-one patients (9%) had hilar renal masses; 405 patients (91%) had nonhilar masses. There was no statistical differences in patient demographics except for larger median tumor size in the hilar cohort (3.2 cm vs 2.6 cm; p=0.001). The only significant difference in operative outcomes was an increase in warm ischemia times for the hilar group versus the nonhilar group (26.3±7.4 min vs 19.6±10.0 min; p=<0.0001). There were no differences in postoperative outcomes; however, there was a trend for increased risk of malignancy and higher stage tumors in the hilar lesion group. Final pathologic margin status was similar in both groups. Only one patient in the nonhilar group had evidence of recurrence at 21 mo. The study was limited by the lack of standard anatomic classification of renal tumors and the potential influence of the surgeons' prior robotic experience. The data represent the largest series of its kind and strongly suggest that RPN is a safe, effective, and feasible option for the minimally invasive approach to renal hilar tumors with no increased risk of adverse outcomes compared with nonhilar tumors in the hands of

  19. Robotic Inguinal Hernia Repair: Technique and Early Experience.

    Science.gov (United States)

    Arcerito, Massimo; Changchien, Eric; Bernal, Oscar; Konkoly-Thege, Adam; Moon, John

    2016-10-01

    Laparoscopic inguinal hernia repair has been shown to have multiple advantages compared with open repair such as less postoperative pain and earlier resume of daily activities with a comparable recurrence rate. We speculate robotic inguinal hernia repair may yield equivalent benefits, while providing the surgeon added dexterity. One hundred consecutive robotic inguinal hernia repairs with mesh were performed with a mean age of 56 years (25-96). Fifty-six unilateral hernias and 22 bilateral hernias were repaired amongst 62 males and 16 females. Polypropylene mesh was used for reconstruction. All but, two patients were completed robotically. Mean operative time was 52 minutes per hernia repair (45-67). Five patients were admitted overnight based on their advanced age. Regular diet was resumed immediately. Postoperative pain was minimal and regular activity was achieved after an average of four days. One patient recurred after three months in our earlier experience and he was repaired robotically. Mean follow-up time was 12 months. These data, compared with laparoscopic approach, suggest similar recurrence rates and postoperative pain. We believe comparative studies with laparoscopic approach need to be performed to assess the role robotic surgery has in the treatment of inguinal hernia repair.

  20. Impact of tamsulosin on urinary retention following early catheter removal after robot-assisted laparoscopic radical prostatectomy: a prospective randomized controlled trial.

    Science.gov (United States)

    Jeong, In Gab; You, Dalsan; Yoon, Jong Hyun; Hong, Sungwoo; Lim, Ju Hyun; Hong, Jun Hyuk; Choo, Myung-Soo; Ahn, Hanjong; Kim, Choung-Soo

    2014-02-01

    To examine the impact of tamsulosin on the rate of acute urinary retention following early catheter removal after robot-assisted laparoscopic radical prostatectomy. A total of 236 patients who underwent robot-assisted laparoscopic radical prostatectomy for prostate cancer carried out by a single surgeon were enrolled in this randomized study. Patients were randomly divided into two groups: treatment with tamsulosin (0.4 mg) from 1 day before to 14 days after surgery (tamsulosin group), or no tamsulosin treatment (control group). The urethral catheter was removed on the fifth postoperative day. The primary end-point was the acute urinary retention rate. Changes in each domain of the International Continence Society male short-form questionnaire and uroflowmetry parameters were secondary end-points. The primary end-point was assessed in 218 patients (92.4%; n = 109 in each group). It was not assessed in 18 patients because of cystographic leak from the vesicourethral anastomosis. The acute urinary retention rate was lower in the tamsulosin group (7.3%) than in the control group (17.4%, P = 0.018). Multivariate logistic regression analysis identified tamsulosin treatment and the operative experience of the surgeon as independent risk factors for acute urinary retention. Tamsulosin-treated patients had a 0.30-fold lower risk of developing acute urinary retention compared with control patients (95% confidence interval 0.12-0.76; P = 0.011). None of the International Continence Society male questionnaire domain scores showed significant changes between the groups. Perioperative treatment with tamsulosin in patients undergoing robot-assisted laparoscopic radical prostatectomy reduces the rate of acute urinary retention after early catheter removal, without aggravating urinary incontinence. © 2013 The Japanese Urological Association.

  1. Designing Robots for Care: Care Centered Value-Sensitive Design

    OpenAIRE

    van Wynsberghe, Aimee

    2012-01-01

    The prospective robots in healthcare intended to be included within the conclave of the nurse-patient relationship?what I refer to as care robots?require rigorous ethical reflection to ensure their design and introduction do not impede the promotion of values and the dignity of patients at such a vulnerable and sensitive time in their lives. The ethical evaluation of care robots requires insight into the values at stake in the healthcare tradition. What?s more, given the stage of their develo...

  2. Surgical robot setup simulation with consistent kinematics and haptics for abdominal surgery.

    Science.gov (United States)

    Hayashibe, Mitsuhiro; Suzuki, Naoki; Hattori, Asaki; Suzuki, Shigeyuki; Konishi, Kozo; Kakeji, Yoshihiro; Hashizume, Makoto

    2005-01-01

    Preoperative simulation and planning of surgical robot setup should accompany advanced robotic surgery if their advantages are to be further pursued. Feedback from the planning system will plays an essential role in computer-aided robotic surgery in addition to preoperative detailed geometric information from patient CT/MRI images. Surgical robot setup simulation systems for appropriate trocar site placement have been developed especially for abdominal surgery. The motion of the surgical robot can be simulated and rehearsed with kinematic constraints at the trocar site, and the inverse-kinematics of the robot. Results from simulation using clinical patient data verify the effectiveness of the proposed system.

  3. An advanced rehabilitation robotic system for augmenting healthcare.

    Science.gov (United States)

    Hu, John; Lim, Yi-Je; Ding, Ye; Paluska, Daniel; Solochek, Aaron; Laffery, David; Bonato, Paolo; Marchessault, Ronald

    2011-01-01

    Emerging technologies such as rehabilitation robots (RehaBot) for retraining upper and lower limb functions have shown to carry tremendous potential to improve rehabilitation outcomes. Hstar Technologies is developing a revolutionary rehabilitation robot system enhancing healthcare quality for patients with neurological and muscular injuries or functional impairments. The design of RehaBot is a safe and robust system that can be run at a rehabilitation hospital under the direct monitoring and interactive supervision control and at a remote site via telepresence operation control. RehaBot has a wearable robotic structure design like exoskeleton, which employs a unique robotic actuation--Series Elastic Actuator. These electric actuators provide robotic structural compliance, safety, flexibility, and required strength for upper extremity dexterous manipulation rehabilitation training. RehaBot also features a novel non-treadmill paddle platform capable of haptics feedback locomotion rehabilitation training. In this paper, we concern mainly about the motor incomplete patient and rehabilitation applications.

  4. Hand-assisted robotic right donor nephrectomy in patient with total sinus inversus: A case report

    Science.gov (United States)

    Gonzalez-Heredia, Raquel; Garcia-Roca, Raquel; Benedetti, Enrico

    2016-01-01

    Total situs inversus” is an infrequent congenital condition. The robot has been already proved as a safe and attractive approach for living donor neprectomies. We report here the first right donor nephrectomy in a patient with total sinus inversus that is performed using the Da Vinci platform. PMID:27085108

  5. Clinical validation of robot simulation of toothbrushing - comparative plaque removal efficacy

    Science.gov (United States)

    2014-01-01

    Background Clinical validation of laboratory toothbrushing tests has important advantages. It was, therefore, the aim to demonstrate correlation of tooth cleaning efficiency of a new robot brushing simulation technique with clinical plaque removal. Methods Clinical programme: 27 subjects received dental cleaning prior to 3-day-plaque-regrowth-interval. Plaque was stained, photographically documented and scored using planimetrical index. Subjects brushed teeth 33–47 with three techniques (horizontal, rotating, vertical), each for 20s buccally and for 20s orally in 3 consecutive intervals. The force was calibrated, the brushing technique was video supported. Two different brushes were randomly assigned to the subject. Robot programme: Clinical brushing programmes were transfered to a 6-axis-robot. Artificial teeth 33–47 were covered with plaque-simulating substrate. All brushing techniques were repeated 7 times, results were scored according to clinical planimetry. All data underwent statistical analysis by t-test, U-test and multivariate analysis. Results The individual clinical cleaning patterns are well reproduced by the robot programmes. Differences in plaque removal are statistically significant for the two brushes, reproduced in clinical and robot data. Multivariate analysis confirms the higher cleaning efficiency for anterior teeth and for the buccal sites. Conclusions The robot tooth brushing simulation programme showed good correlation with clinically standardized tooth brushing. This new robot brushing simulation programme can be used for rapid, reproducible laboratory testing of tooth cleaning. PMID:24996973

  6. Haptic-based neurorehabilitation in poststroke patients: a feasibility prospective multicentre trial for robotics hand rehabilitation.

    Science.gov (United States)

    Turolla, Andrea; Daud Albasini, Omar A; Oboe, Roberto; Agostini, Michela; Tonin, Paolo; Paolucci, Stefano; Sandrini, Giorgio; Venneri, Annalena; Piron, Lamberto

    2013-01-01

    Background. Haptic robots allow the exploitation of known motor learning mechanisms, representing a valuable option for motor treatment after stroke. The aim of this feasibility multicentre study was to test the clinical efficacy of a haptic prototype, for the recovery of hand function after stroke. Methods. A prospective pilot clinical trial was planned on 15 consecutive patients enrolled in 3 rehabilitation centre in Italy. All the framework features of the haptic robot (e.g., control loop, external communication, and graphic rendering for virtual reality) were implemented into a real-time MATLAB/Simulink environment, controlling a five-bar linkage able to provide forces up to 20 [N] at the end effector, used for finger and hand rehabilitation therapies. Clinical (i.e., Fugl-Meyer upper extremity scale; nine hold pegboard test) and kinematics (i.e., time; velocity; jerk metric; normalized jerk of standard movements) outcomes were assessed before and after treatment to detect changes in patients' motor performance. Reorganization of cortical activation was detected in one patient by fMRI. Results and Conclusions. All patients showed significant improvements in both clinical and kinematic outcomes. Additionally, fMRI results suggest that the proposed approach may promote a better cortical activation in the brain.

  7. Haptic-Based Neurorehabilitation in Poststroke Patients: A Feasibility Prospective Multicentre Trial for Robotics Hand Rehabilitation

    Directory of Open Access Journals (Sweden)

    Andrea Turolla

    2013-01-01

    Full Text Available Background. Haptic robots allow the exploitation of known motorlearning mechanisms, representing a valuable option for motor treatment after stroke. The aim of this feasibility multicentre study was to test the clinical efficacy of a haptic prototype, for the recovery of hand function after stroke. Methods. A prospective pilot clinical trial was planned on 15 consecutive patients enrolled in 3 rehabilitation centre in Italy. All the framework features of the haptic robot (e.g., control loop, external communication, and graphic rendering for virtual reality were implemented into a real-time MATLAB/Simulink environment, controlling a five-bar linkage able to provide forces up to 20 [N] at the end effector, used for finger and hand rehabilitation therapies. Clinical (i.e., Fugl-Meyer upper extremity scale; nine hold pegboard test and kinematics (i.e., time; velocity; jerk metric; normalized jerk of standard movements outcomes were assessed before and after treatment to detect changes in patients' motor performance. Reorganization of cortical activation was detected in one patient by fMRI. Results and Conclusions. All patients showed significant improvements in both clinical and kinematic outcomes. Additionally, fMRI results suggest that the proposed approach may promote a better cortical activation in the brain.

  8. Predictors of weight regain in patients who underwent Roux-en-Y gastric bypass surgery.

    Science.gov (United States)

    Shantavasinkul, Prapimporn Chattranukulchai; Omotosho, Philip; Corsino, Leonor; Portenier, Dana; Torquati, Alfonso

    2016-11-01

    Roux-en-Y gastric bypass (RYGB) is a highly effective treatment for obesity and results in long-term weight loss and resolution of co-morbidities. However, weight regain may occur as soon as 1-2 years after surgery. This retrospective study aimed to investigate the prevalence of weight regain and possible preoperative predictors of this phenomenon after RYGB. An academic medical center in the United States. A total of 1426 obese patients (15.8% male) who underwent RYGB during January 2000 to 2012 and had at least a 2-year follow-up were reviewed. We included only patients who were initially successful, having achieved at least 50% excess weight loss at 1 year postoperatively. Patients were then categorized into either the weight regain group (WR) or sustained weight loss (SWL) group based upon whether they gained≥15% of their 1-year postoperative weight. Weight regain was observed in 244 patients (17.1%). Preoperative body mass index was similar between groups. Body mass index was significantly higher and percent excess weight loss was significantly lower in the WR group (Pweight regain was 19.5±9.3 kg and-.8±8.5 in the WR and SWL groups, respectively (Pweight loss. Moreover, a longer duration after RYGB was associated with weight regain. Multivariate analysis revealed that younger age was a significant predictor of weight regain even after adjusting for time since RYGB. The present study confirmed that a longer interval after RYGB was associated with weight regain. Younger age was a significant predictor of weight regain even after adjusting for time since RYGB. The findings of this study underscore the complexity of the mechanisms underlying weight loss and regain after RYGB. Future prospective studies are needed to further explore the prevalence, predictors, and mechanisms of weight regain after RYGB. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  9. Robotics

    International Nuclear Information System (INIS)

    Scheide, A.W.

    1983-01-01

    This article reviews some of the technical areas and history associated with robotics, provides information relative to the formation of a Robotics Industry Committee within the Industry Applications Society (IAS), and describes how all activities relating to robotics will be coordinated within the IEEE. Industrial robots are being used for material handling, processes such as coating and arc welding, and some mechanical and electronics assembly. An industrial robot is defined as a programmable, multifunctional manipulator designed to move material, parts, tools, or specialized devices through variable programmed motions for a variety of tasks. The initial focus of the Robotics Industry Committee will be on the application of robotics systems to the various industries that are represented within the IAS

  10. Inducing self-selected human engagement in robotic locomotion training.

    Science.gov (United States)

    Collins, Steven H; Jackson, Rachel W

    2013-06-01

    Stroke leads to severe mobility impairments for millions of individuals each year. Functional outcomes can be improved through manual treadmill therapy, but high costs limit patient exposure and, thereby, outcomes. Robotic gait training could increase the viable duration and frequency of training sessions, but robotic approaches employed thus far have been less effective than manual therapy. These shortcomings may relate to subconscious energy-minimizing drives, which might cause patients to engage less actively in therapy when provided with corrective robotic assistance. We have devised a new method for gait rehabilitation that harnesses, rather than fights, least-effort tendencies. Therapeutic goals, such as increased use of the paretic limb, are made easier than the patient's nominal gait through selective assistance from a robotic platform. We performed a pilot test on a healthy subject (N = 1) in which altered self-selected stride length was induced using a tethered robotic ankle-foot orthosis. The subject first walked on a treadmill while wearing the orthosis with and without assistance at unaltered and voluntarily altered stride length. Voluntarily increasing stride length by 5% increased metabolic energy cost by 4%. Robotic assistance decreased energy cost at both unaltered and voluntarily increased stride lengths, by 6% and 8% respectively. We then performed a test in which the robotic system continually monitored stride length and provided more assistance if the subject's stride length approached a target increase. This adaptive assistance protocol caused the subject to slowly adjust their gait patterns towards the target, leading to a 4% increase in stride length. Metabolic energy consumption was simultaneously reduced by 5%. These results suggest that selective-assistance protocols based on targets relevant to rehabilitation might lead patients to self-select desirable gait patterns during robotic gait training sessions, possibly facilitating better

  11. MODULAR MANIPULATOR FOR ROBOTICS APPLICATIONS

    International Nuclear Information System (INIS)

    Geisinger, Joseph W. Ph.D.

    2001-01-01

    ARM Automation, Inc. is developing a FR-amework of modular actuators that can address the DOE's wide range of robotics needs. The objective of this effort is to demonstrate the effectiveness of this technology by constructing a manipulator FR-om these actuators within a glovebox for Automated Plutonium Processing (APP). At the end of the project, the system of actuators was used to construct several different manipulator configurations, which accommodate common glovebox tasks such as repackaging. The modular nature and quickconnects of this system simplify installation into ''hot'' boxes and any potential modifications or repair therein. This work focused on the development of self-contained robotic actuator modules including the embedded electronic controls for the purpose of building a manipulator system. Both of the actuators developed under this project contain the control electronics, sensors, motor, gear train, wiring, system communications and mechanical interfaces of a complete robotics servo device. Test actuators and accompanying DISC(trademark)s underwent validation testing at The University of Texas at Austin and ARM Automation, Inc. following final design and fabrication. The system also included custom links, an umbilical cord, an open architecture PC-based system controller, and operational software that permitted integration into a completely functional robotic manipulator system. The open architecture on which this system is based avoids proprietary interfaces and communication protocols which only serve to limit the capabilities and flexibility of automation equipment. The system was integrated and tested in the contractor's facility for intended performance and operations. The manipulator was tested using the full-scale equipment and process mock-ups. The project produced a practical and operational system including a quantitative evaluation of its performance and cost

  12. Thoracoscopic versus robotic approaches: advantages and disadvantages.

    Science.gov (United States)

    Wei, Benjamin; D'Amico, Thomas A

    2014-05-01

    The overall advantages of thoracoscopy over thoracotomy in terms of patient recovery have been fairly well established. The use of robotics, however, is a newer and less proven modality in the realm of thoracic surgery. Robotics offers distinct advantages and disadvantages in comparison with video-assisted thoracoscopic surgery. Robotic technology is now used for a variety of complex cardiac, urologic, and gynecologic procedures including mitral valve repair and microsurgical treatment of male infertility. This article addresses the potential benefits and limitations of using the robotic platform for the performance of a variety of thoracic operations. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Robot-assisted vitreoretinal surgery: current perspectives.

    Science.gov (United States)

    Roizenblatt, Marina; Edwards, Thomas L; Gehlbach, Peter L

    2018-01-01

    Vitreoretinal microsurgery is among the most technically challenging of the minimally invasive surgical techniques. Exceptional precision is required to operate on micron scale targets presented by the retina while also maneuvering in a tightly constrained and fragile workspace. These challenges are compounded by inherent limitations of the unassisted human hand with regard to dexterity, tremor and precision in positioning instruments. The limited human ability to visually resolve targets on the single-digit micron scale is a further limitation. The inherent attributes of robotic approaches therefore, provide logical, strategic and promising solutions to the numerous challenges associated with retinal microsurgery. Robotic retinal surgery is a rapidly emerging technology that has witnessed an exponential growth in capabilities and applications over the last decade. There is now a worldwide movement toward evaluating robotic systems in an expanding number of clinical applications. Coincident with this expanding application is growth in the number of laboratories committed to "robotic medicine". Recent technological advances in conventional retina surgery have also led to tremendous progress in the surgeon's capabilities, enhanced outcomes, a reduction of patient discomfort, limited hospitalization and improved safety. The emergence of robotic technology into this rapidly advancing domain is expected to further enhance important aspects of the retinal surgery experience for the patients, surgeons and society.

  14. Robotics and general surgery.

    Science.gov (United States)

    Jacob, Brian P; Gagner, Michel

    2003-12-01

    Robotics are now being used in all surgical fields, including general surgery. By increasing intra-abdominal articulations while operating through small incisions, robotics are increasingly being used for a large number of visceral and solid organ operations, including those for the gallbladder, esophagus, stomach, intestines, colon, and rectum, as well as for the endocrine organs. Robotics and general surgery are blending for the first time in history and as a specialty field should continue to grow for many years to come. We continuously demand solutions to questions and limitations that are experienced in our daily work. Laparoscopy is laden with limitations such as fixed axis points at the trocar insertion sites, two-dimensional video monitors, limited dexterity at the instrument tips, lack of haptic sensation, and in some cases poor ergonomics. The creation of a surgical robot system with 3D visual capacity seems to deal with most of these limitations. Although some in the surgical community continue to test the feasibility of these surgical robots and to question the necessity of such an expensive venture, others are already postulating how to improve the next generation of telemanipulators, and in so doing are looking beyond today's horizon to find simpler solutions. As the robotic era enters the world of the general surgeon, more and more complex procedures will be able to be approached through small incisions. As technology catches up with our imaginations, robotic instruments (as opposed to robots) and 3D monitoring will become routine and continue to improve patient care by providing surgeons with the most precise, least traumatic ways of treating surgical disease.

  15. Robotic automation of medication-use management.

    Science.gov (United States)

    Enright, S M

    1993-11-01

    In the October 1993 issue of Physician Assistant, we published "Robots for Health Care," the first of two articles on the medical applications of robotics. That article discussed ways in which robots could help patients with manipulative disabilities to perform activities of daily living and hold paid employment; transfer patients from bed to chair and back again; add precision to the most exacting surgical procedures; and someday carry out diagnostic and therapeutic techniques from within the human body. This month, we are pleased to offer an article by Sharon Enright, an authority on pharmacy operations, who considers how an automated medication-management system that makes use of bar-code technology is capable of streamlining drug dispensing, controlling safety, increasing cost-effectiveness, and ensuring accurate and complete record-keeping.

  16. Hand-assisted robotic right donor nephrectomy in patient with total situs inversus: A case report.

    Science.gov (United States)

    Gonzalez-Heredia, Raquel; Garcia-Roca, Raquel; Benedetti, Enrico

    2016-01-01

    Total situs inversus" is an infrequent congenital condition. The robot has been already proved as a safe and attractive approach for living donor nephrectomies. We report here the first right donor nephrectomy in a patient with total situs inversus that is performed using the Da Vinci platform. Published by Elsevier Ltd.

  17. Hand-assisted robotic right donor nephrectomy in patient with total situs inversus: A case report

    Directory of Open Access Journals (Sweden)

    Raquel Gonzalez-Heredia

    2016-01-01

    Full Text Available Total situs inversus” is an infrequent congenital condition. The robot has been already proved as a safe and attractive approach for living donor nephrectomies. We report here the first right donor nephrectomy in a patient with total situs inversus that is performed using the Da Vinci platform.

  18. Robotic neurorehabilitation system design for stroke patients

    Directory of Open Access Journals (Sweden)

    Baoguo Xu

    2015-03-01

    Full Text Available In this article, a neurorehabilitation system combining robot-aided rehabilitation with motor imagery–based brain–computer interface is presented. Feature extraction and classification algorithm for the motor imagery electroencephalography is implemented under our brain–computer interface research platform. The main hardware platform for functional recovery therapy is the Barrett Whole-Arm Manipulator. The mental imagination of upper limb movements is translated to trigger the Barrett Whole-Arm Manipulator Arm to stretch the affected upper limb to move along the predefined trajectory. A fuzzy proportional–derivative position controller is proposed to control the Whole-Arm Manipulator Arm to perform passive rehabilitation training effectively. A preliminary experiment aimed at testing the proposed system and gaining insight into the potential of motor imagery electroencephalography-triggered robotic therapy is reported.

  19. Feasibility of robotic radical prostatectomy for medication refractory chronic prostatitis/chronic pelvic pain syndrome: Initial results

    Directory of Open Access Journals (Sweden)

    Sameer Chopra

    2016-01-01

    Full Text Available Four patients diagnosed with chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS, met criteria for National Institute of Health (NIH Category III prostatitis, failed multiple medicinal treatments and underwent robotic radical prostatectomy (RRP. Median operative time (range: 157 (127–259 min. Validated functional questionnaires responses and NIH CP symptom index (NIH-CPSI score were collected for each patient's status at different time points pre- and post-operatively. Median decreases (range were: International Prostate Symptom Score - 14 (1–19; Sexual Health Inventory for Men - 6 (−14–22; and NIH-CPSI total - 23.5 (13–33. Median length of follow-up (range was 34 (24–43 months. RRP appears to be an option for carefully selected patients with medication-refractory CP/CPPS who understand that baseline sexual function may not be restored postoperatively.

  20. Robots testing robots: ALAN-Arm, a humanoid arm for the testing of robotic rehabilitation systems.

    Science.gov (United States)

    Brookes, Jack; Kuznecovs, Maksims; Kanakis, Menelaos; Grigals, Arturs; Narvidas, Mazvydas; Gallagher, Justin; Levesley, Martin

    2017-07-01

    Robotics is increasing in popularity as a method of providing rich, personalized and cost-effective physiotherapy to individuals with some degree of upper limb paralysis, such as those who have suffered a stroke. These robotic rehabilitation systems are often high powered, and exoskeletal systems can attach to the person in a restrictive manner. Therefore, ensuring the mechanical safety of these devices before they come in contact with individuals is a priority. Additionally, rehabilitation systems may use novel sensor systems to measure current arm position. Used to capture and assess patient movements, these first need to be verified for accuracy by an external system. We present the ALAN-Arm, a humanoid robotic arm designed to be used for both accuracy benchmarking and safety testing of robotic rehabilitation systems. The system can be attached to a rehabilitation device and then replay generated or human movement trajectories, as well as autonomously play rehabilitation games or activities. Tests of the ALAN-Arm indicated it could recreate the path of a generated slow movement path with a maximum error of 14.2mm (mean = 5.8mm) and perform cyclic movements up to 0.6Hz with low gain (<1.5dB). Replaying human data trajectories showed the ability to largely preserve human movement characteristics with slightly higher path length and lower normalised jerk.

  1. Periodical assessment of genitourinary and gastrointestinal toxicity in patients who underwent prostate low-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Nobumichi; Asakawa, Isao; Anai, Satoshi; Hirayama, Akihide; Hasegawa, Masatoshi; Konishi, Noboru; Fujimoto, Kiyohide

    2013-01-01

    To compare the periodical incidence rates of genitourinary (GU) and gastrointestinal (GI) toxicity in patients who underwent prostate low-dose-rate brachytherapy between the monotherapy group (seed implantation alone) and the boost group (in combination with external beam radiation therapy (EBRT)). A total of 218 patients with a median follow-up of 42.5 months were enrolled. The patients were divided into 2 groups by treatment modality, namely, the monotherapy group (155 patients) and the boost group (63 patients). The periodical incidence rates of GU and GI toxicity were separately evaluated and compared between the monotherapy group and the boost group using the National Cancer Institute - Common Terminology Criteria for Adverse Events, version 3.0. To elucidate an independent factor among clinical and postdosimetric parameters to predict grade 2 or higher GU and GI toxicity in the acute and late phases, univariate and multivariate logistic regression analyses were carried out. Of all patients, 78.0% showed acute GU toxicity, and 7.8% showed acute GI toxicity, while 63.8% showed late GU toxicity, and 21.1% showed late GI toxicity. The incidence rates of late GU and GI toxicity were significantly higher in the boost group. Multivariate analysis showed that the International Prostate Symptom Score (IPSS) before seed implantation was a significant parameter to predict acute GU toxicity, while there were no significant predictive parameters for acute GI toxicity. On the other hand, combination with EBRT was a significant predictive parameter for late GU toxicity, and rectal volume (mL) receiving 100% of the prescribed dose (R100) was a significant predictive parameter for late GI toxicity. The boost group showed higher incidence rates of both GU and GI toxicity. Higher IPSS before seed implantation, combination with EBRT and a higher R100 were significant predictors for acute GU, late GU and late GI toxicity

  2. Towards Versatile Robots Through Open Heterogeneous Modular Robots

    DEFF Research Database (Denmark)

    Lyder, Andreas

    arises, a new robot can be assembled rapidly from the existing modules, in contrast to conventional robots, which require a time consuming and expensive development process. In this thesis we define a modular robot to be a robot consisting of dynamically reconfigurable modules. The goal of this thesis......Robots are important tools in our everyday life. Both in industry and at the consumer level they serve the purpose of increasing our scope and extending our capabilities. Modular robots take the next step, allowing us to easily create and build various robots from a set of modules. If a problem...... is to increase the versatility and practical usability of modular robots by introducing new conceptual designs. Until now modular robots have been based on a pre-specified set of modules, and thus, their functionality is limited. We propose an open heterogeneous design concept, which allows a modular robot...

  3. Robot-assisted gait training versus treadmill training in patients with Parkinson’s disease: a kinematic evaluation with gait profile score

    Science.gov (United States)

    Galli, Manuela; Cimolin, Veronica; De Pandis, Maria Francesca; Le Pera, Domenica; Sova, Ivan; Albertini, Giorgio; Stocchi, Fabrizio; Franceschini, Marco

    2016-01-01

    Summary The purpose of this study was to quantitatively compare the effects, on walking performance, of end-effector robotic rehabilitation locomotor training versus intensive training with a treadmill in Parkinson’s disease (PD). Fifty patients with PD were randomly divided into two groups: 25 were assigned to the robot-assisted therapy group (RG) and 25 to the intensive treadmill therapy group (IG). They were evaluated with clinical examination and 3D quantitative gait analysis [gait profile score (GPS) and its constituent gait variable scores (GVSs) were calculated from gait analysis data] at the beginning (T0) and at the end (T1) of the treatment. In the RG no differences were found in the GPS, but there were significant improvements in some GVSs (Pelvic Obl and Hip Ab-Add). The IG showed no statistically significant changes in either GPS or GVSs. The end-effector robotic rehabilitation locomotor training improved gait kinematics and seems to be effective for rehabilitation in patients with mild PD. PMID:27678210

  4. Megarectumsigma underwent surgery for chronic faecal impact action

    International Nuclear Information System (INIS)

    Canessa, C.; Gomez del Valle, M.; Caraballo, M.

    2002-01-01

    Seven patients with megarectumsigma underwent surgery for chronic faecal impaction,reviewing clinical diagnosis, aetiology and medical and surgical management.It is suggested medical management of chronic faecal impaction trying to achieve elective surgery.The curative surgery should include the resection of all pathologic bowel, but in Duhamel procedure and its modifications distal rectal tran section should be at the peritoneal reflection.Habr-Gama modification has shown to be technically easier and it has been communicated good functional results.Local unfavourable conditions may be resolve by staged surgery,which allows outline definitive bowel reconstruction after functional assessment

  5. Robotic unclamped "minimal-margin" partial nephrectomy: ongoing refinement of the anatomic zero-ischemia concept.

    Science.gov (United States)

    Satkunasivam, Raj; Tsai, Sheaumei; Syan, Sumeet; Bernhard, Jean-Christophe; de Castro Abreu, Andre Luis; Chopra, Sameer; Berger, Andre K; Lee, Dennis; Hung, Andrew J; Cai, Jie; Desai, Mihir M; Gill, Inderbir S

    2015-10-01

    Anatomic partial nephrectomy (PN) techniques aim to decrease or eliminate global renal ischemia. To report the technical feasibility of completely unclamped "minimal-margin" robotic PN. We also illustrate the stepwise evolution of anatomic PN surgery with related outcomes data. This study was a retrospective analysis of 179 contemporary patients undergoing anatomic PN at a tertiary academic institution between October 2009 and February 2013. Consecutive consented patients were grouped into three cohorts: group 1, with superselective clamping and developmental-curve experience (n = 70); group 2, with superselective clamping and mature experience (n = 60); and group 3, which had completely unclamped, minimal-margin PN (n = 49). Patients in groups 1 and 2 underwent superselective tumor-specific devascularization, whereas patients in group 3 underwent completely unclamped minimal-margin PN adjacent to the tumor edge, a technique that takes advantage of the radially oriented intrarenal architecture and anatomy. Primary outcomes assessed the technical feasibility of robotic, completely unclamped, minimal-margin PN; short-term changes in estimated glomerular filtration rate (eGFR); and development of new-onset chronic kidney disease (CKD) stage >3. Secondary outcome measures included perioperative variables, 30-d complications, and histopathologic outcomes. Demographic data were similar among groups. For similarly sized tumors (p = 0.13), percentage of kidney preserved was greater (p = 0.047) and margin width was narrower (p = 0.0004) in group 3. In addition, group 3 had less blood loss (200, 225, and 150ml; p = 0.04), lower transfusion rates (21%, 23%, and 4%; p = 0.008), and shorter hospital stay (p = 0.006), whereas operative time and 30-d complication rates were similar. At 1-mo postoperatively, median percentage reduction in eGFR was similar (7.6%, 0%, and 3.0%; p = 0.53); however, new-onset CKD stage >3 occurred less frequently in group 3 (23%, 10%, and 2%; p = 0

  6. Robotic radical hysterectomy with pelvic lymphadenectomy: our early experience.

    Science.gov (United States)

    Vasilescu, C; Sgarbură, O; Tudor, St; Popa, M; Turcanu, A; Florescu, A; Herlea, V; Anghel, R

    2009-01-01

    Robotic surgery overcomes some limitations of laparoscopic surgery for prostate, rectal and uterine cancer. In this study we analyze the feasibility of robotic radical hysterectomy with pelvic lymphadenectomy in gynecological cancers in a developping program of robotic surgery. This prospective study started the 1st of March 2008. Since then, 250 cases of robotic surgery were performed out of which 29 cases addressed gynecological conditions. We selected all radical interventions summing up to 19 cases. Our final group consisted of 19 patients, a gedbetween 30 and 78 years old, with an average age of 53.22 years (+/- 10.03). Twelve patients were diagnosed with cervical cancer, the rest of them with endometrial cancer. Mean operative time was 180 +/- 23.45 min. Oral intake were started the next day after the operation and the patients were discharged 3.5 (+/- 1.2) days postoperatively. There were 3 urinary complications in patients with tumors adherent to the urinary bladder. We believe that robotic radical hysterectomy with pelvic lymphadenectomy in gynecological cancers is a rapid, feasible, and secure method that should be used whenever available. However further prospective studies and late follow-up results are needed in order to fully assess the value of this new technology.

  7. Human versus Robot: A Propensity-Matched Analysis of the Accuracy of Free Hand versus Robotic Guidance for Placement of S2 Alar-Iliac (S2AI) Screws.

    Science.gov (United States)

    Shillingford, Jamal N; Laratta, Joseph L; Park, Paul J; Lombardi, Joseph M; Tuchman, Alexander; Saifi, Comron S; Lehman, Ronald A; Lenke, Lawrence G

    2018-04-18

    Retrospective matched cohort analysis. To compare the accuracy of S2 alar-iliac (S2AI) screw placement by robotic guidance versus free hand technique. Spinopelvic fixation utilizing S2AI screws provides optimal fixation across the lumbosacral junction allowing for solid fusion, especially in long segment fusion constructs. Traditionally, S2AI screw placement has required fluoroscopic guidance for accurate screw placement. Herein, we present the first series comparing a free hand and robotic-guided technique for S2AI screw placement. Sixty-eight consecutive patients who underwent S2AI screw placement by either a free hand or robotic technique between 2015 and 2016 were reviewed. Propensity score-matching was utilized to control for preoperative characteristic imbalances. Screw position and accuracy were evaluated using three-dimensional manipulation of CT reconstructions from intraoperative O-arm imaging. A total of 51 patients (105 screws) were matched, 28 (59 screws) in the free hand group (FHG) and 23 (46 screws) in the robot group (RG). The mean age in the FHG and RG were 57.9[REPLACEMENT CHARACTER]± 14.6 years and 61.6[REPLACEMENT CHARACTER]± 12.0 years (P = 0.342), respectively. The average caudal angle in the sagittal plane was significantly larger in the RG (31.0[REPLACEMENT CHARACTER]± 10.0° vs. 25.7[REPLACEMENT CHARACTER]± 8.8°, P =[REPLACEMENT CHARACTER]0.005). There was no difference between the FHG and RG in the horizontal angle, measured in the axial plane using the posterior superior iliac spine (PSIS) as a reference (41.1[REPLACEMENT CHARACTER]± 8.1° vs. 42.8[REPLACEMENT CHARACTER]± 6.6°, P =[REPLACEMENT CHARACTER]0.225), or the S2AI to S1 screw angle (9.4[REPLACEMENT CHARACTER]± 7.0° vs. 11.3[REPLACEMENT CHARACTER]± 9.9°, P =[REPLACEMENT CHARACTER]0.256), respectively. There was no difference in the overall accuracy between FHG and RG (94.9% vs. 97.8%, P =[REPLACEMENT CHARACTER]0.630). Additionally, there

  8. Robotic partial nephrectomy for complex renal tumors: surgical technique.

    Science.gov (United States)

    Rogers, Craig G; Singh, Amar; Blatt, Adam M; Linehan, W Marston; Pinto, Peter A

    2008-03-01

    Laparoscopic partial nephrectomy requires advanced training to accomplish tumor resection and renal reconstruction while minimizing warm ischemia times. Complex renal tumors add an additional challenge to a minimally invasive approach to nephron-sparing surgery. We describe our technique, illustrated with video, of robotic partial nephrectomy for complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance was used to resect 14 tumors in eight patients (mean age: 50.3 yr; range: 30-68 yr). Three patients had hereditary kidney cancer. All patients had complex tumor features, including hilar tumors (n=5), endophytic tumors (n=4), and/or multiple tumors (n=3). Robotic partial nephrectomy procedures were performed successfully without complications. Hilar clamping was used with a mean warm ischemia time of 31 min (range: 24-45 min). Mean blood loss was 230 ml (range: 100-450 ml). Histopathology confirmed clear-cell renal cell carcinoma (n=3), hybrid oncocytic tumor (n=2), chromophobe renal cell carcinoma (n=2), and oncocytoma (n=1). All patients had negative surgical margins. Mean index tumor size was 3.6 cm (range: 2.6-6.4 cm). Mean hospital stay was 2.6 d. At 3-mo follow-up, no patients experienced a statistically significant change in serum creatinine or estimated glomerular filtration rate and there was no evidence of tumor recurrence. Robotic partial nephrectomy is safe and feasible for select patients with complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance may facilitate a minimally invasive, nephron-sparing approach for select patients with complex renal tumors who might otherwise require open surgery or total nephrectomy.

  9. The immediate effects of robot-assistance on energy consumption and cardiorespiratory load during walking compared to walking without robot-assistance: a systematic review.

    Science.gov (United States)

    Lefeber, Nina; Swinnen, Eva; Kerckhofs, Eric

    2017-10-01

    The integration of sufficient cardiovascular stress into robot-assisted gait (RAG) training could combine the benefits of both RAG and aerobic training. The aim was to summarize literature data on the immediate effects of RAG compared to walking without robot-assistance on metabolic-, cardiorespiratory- and fatigue-related parameters. PubMed and Web of Science were searched for eligible articles till February 2016. Means, SDs and significance values were extracted. Effect sizes were calculated. Fourteen studies were included, concerning 155 participants (85 healthy subjects, 39 stroke and 31 spinal cord injury patients), 9 robots (2 end-effectors, 1 treadmill-based and 6 wearable exoskeletons), and 7 outcome parameters (mostly oxygen consumption and heart rate). Overall, metabolic and cardiorespiratory parameters were lower during RAG compared to walking without robot-assistance (moderate to large effect sizes). In healthy subjects, when no body-weight support (BWS) was provided, RAG with an end-effector device was more energy demanding than walking overground (p > .05, large effect sizes). Generally, results suggest that RAG is less energy-consuming and cardiorespiratory stressful than walking without robot-assistance, but results depend on factors such as robot type, walking speed, BWS and effort. Additional research is needed to draw firm conclusions. Implications for Rehabilitation Awareness of the energy consumption and cardiorespiratory load of robot-assisted gait (RAG) training is important in the rehabilitation of (neurological) patients with impaired cardiorespiratory fitness and patients who are at risk of cardiovascular diseases. On the other hand, the integration of sufficient cardiometabolic stress in RAG training could combine the effects of both RAG and aerobic training. Energy consumption and cardiorespiratory load during walking with robot-assistance seems to depend on factors such as robot type, walking speed, body-weight support or amount of

  10. The effects of transfusion of irradiated blood upon cellular immune response in patients underwent open heart surgery

    International Nuclear Information System (INIS)

    Togashi, Ken-ichi; Nakazawa, Satoshi; Moro, Hisanaga; Yazawa, Masatomo; Kanazawa, Hiroshi; Hayashi, Jun-ichi; Yamazaki, Yoshihiko; Eguchi, Shoji

    1989-01-01

    The purpose of this paper is to demonstrate the effect of the transfusion of blood received 1500 rad exposure upon the immune response in 14 patients underwent various type of cardiac surgery. 13 patients received known amounts banked blood and irradiated fresh blood, while one patient received a lot of amounts of banked and irradiated and non-irradiated fresh blood. The authors studied the numbers of lymphocytes as well as lymphocyte subsets such as pan-T cells, B cells, helper/inducer T cells (T H/I ), cytotoxic/supressor T cells (T C/S ), active T cells, natural killer (NK) cells and NK cell activity during two weeks after surgeries. In all 14 patients, pan-T lymphocytes decreased markedly in a few days after surgeries, but increased to higher levels on the eight postoperative day than the levels preoperatively. T H/I and T C/S lymphocytes changed on the similar pattern as pan-T lymphocytes. Active T and B cells did not change significantly in two weeks. The number and activity of NK cells gave the lowest levels on the second postoperative day and did not recovery to the preoperative levels in two weeks. One patient received non-irradiated fresh blood showed the similar immune response as other 13 patients, while he gave the lower levels than others did. This patient died of graft-versus-host disease (GVHD)-like syndrome on the 36th postoperative day. It may be thought that the transfusion of irradiated blood would prevent the host from GVHD and gave the better effects on the immune response than that of non-irradiated blood following open-heart surgeries. (author)

  11. Socially intelligent robots: dimensions of human-robot interaction.

    Science.gov (United States)

    Dautenhahn, Kerstin

    2007-04-29

    Social intelligence in robots has a quite recent history in artificial intelligence and robotics. However, it has become increasingly apparent that social and interactive skills are necessary requirements in many application areas and contexts where robots need to interact and collaborate with other robots or humans. Research on human-robot interaction (HRI) poses many challenges regarding the nature of interactivity and 'social behaviour' in robot and humans. The first part of this paper addresses dimensions of HRI, discussing requirements on social skills for robots and introducing the conceptual space of HRI studies. In order to illustrate these concepts, two examples of HRI research are presented. First, research is surveyed which investigates the development of a cognitive robot companion. The aim of this work is to develop social rules for robot behaviour (a 'robotiquette') that is comfortable and acceptable to humans. Second, robots are discussed as possible educational or therapeutic toys for children with autism. The concept of interactive emergence in human-child interactions is highlighted. Different types of play among children are discussed in the light of their potential investigation in human-robot experiments. The paper concludes by examining different paradigms regarding 'social relationships' of robots and people interacting with them.

  12. Robotic kidney transplantation with regional hypothermia: evolution of a novel procedure utilizing the IDEAL guidelines (IDEAL phase 0 and 1).

    Science.gov (United States)

    Menon, Mani; Abaza, Ronney; Sood, Akshay; Ahlawat, Rajesh; Ghani, Khurshid R; Jeong, Wooju; Kher, Vijay; Kumar, Ramesh K; Bhandari, Mahendra

    2014-05-01

    Surgical innovation is essential for progress of surgical science, but its implementation comes with potential harms during the learning phase. The Balliol Collaboration has recommended a set of guidelines (Innovation, Development, Exploration, Assessment, Long-term study [IDEAL]) that permit innovation while minimizing complications. To utilize the IDEAL model of surgical innovation in the development of a novel surgical technique, robotic kidney transplantation (RKT) with regional hypothermia, and describe the process of discovery and development. Phase 0 (simulation) studies included the establishment of techniques for pelvic cooling, graft placement in a robotic prostatectomy model, and simulation of the RKT procedure in a cadaveric model. Phase 1 (innovation) studies began in January 2013 and involved treatment of a highly selective small group of patients (n=7), using the principles utilized in the phase 0 studies, at a tertiary referral center. IDEAL model implementation in the development of RKT with regional hypothermia. For phase 0 studies, the outcomes evaluated included pelvic and body temperature measurements, and technical feasibility assessment. The primary outcome during phase 1 was post-transplant graft function. Other outcomes measured were operative and ischemic times, perioperative complications, and intracorporeal graft surface temperature. Phase 0 (simulation phase): Pelvic cooling to 15-20(o)C was achieved reproducibly. Using the surgical approach developed for robotic radical prostatectomy, vascular and ureterovesical anastomoses could be done without redocking the robot. Phase 1 (innovation phase): All patients underwent live-donor RKT in the lithotomy position. All grafts functioned immediately. Mean console, anastomotic, and warm ischemia times were 154 min, 29 min, and 2 min, respectively. One patient was re-explored on postoperative day 1. Adherence to the IDEAL guidelines put forth by the Balliol Collaboration provided a practical

  13. Percutaneous cystostomy drainage for early removing urethral catheter in robotic-assisted laparoscopic radical prostatectomy: Improving on patients' discomfort

    Directory of Open Access Journals (Sweden)

    Che-Jui Yang

    2015-12-01

    Conclusion: The use of a percutaneous cystostomy device is feasible and safe for the early removal of urethral Foley catheter in robotic-assisted laparoscopic radical prostatectomy to decrease penile pain and patient discomfort.

  14. Robot-Aided Upper-Limb Rehabilitation Based on Motor Imagery EEG

    Directory of Open Access Journals (Sweden)

    Baoguo Xu

    2011-09-01

    Full Text Available Stroke is a leading cause of disability worldwide. In this paper, a novel robot-assisted rehabilitation system based on motor imagery electroencephalography (EEG is developed for regular training of neurological rehabilitation for upper limb stroke patients. Firstly, three-dimensional animation was used to guide the patient image the upper limb movement and EEG signals were acquired by EEG amplifier. Secondly, eigenvectors were extracted by harmonic wavelet transform (HWT and linear discriminant analysis (LDA classifier was utilized to classify the pattern of the left and right upper limb motor imagery EEG signals. Finally, PC triggered the upper limb rehabilitation robot to perform motor therapy and gave the virtual feedback. Using this robot-assisted upper limb rehabilitation system, the patient's EEG of upper limb movement imagination is translated to control rehabilitation robot directly. Consequently, the proposed rehabilitation system can fully explore the patient's motivation and attention and directly facilitate upper limb post-stroke rehabilitation therapy. Experimental results on unimpaired participants were presented to demonstrate the feasibility of the rehabilitation system. Combining robot-assisted training with motor imagery-based BCI will make future rehabilitation therapy more effective. Clinical testing is still required for further proving this assumption.

  15. Phase II clinical trial of robotic stereotactic body radiosurgery for metastatic gynecologic malignancies

    Directory of Open Access Journals (Sweden)

    Charles eKunos

    2012-12-01

    Full Text Available Background Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT in women with metastatic gynecologic cancers. Methods A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4 metastases underwent robotic-armed Cyberknife SBRT (24Gy/3 daily doses. Toxicities were graded prospectively by common toxicity criteria for adverse events (version 4.0. SBRT target responses were recorded following RECIST criteria (version 1.0. Rates of clinical benefit for SBRT and non-radiosurgical disease relapse were calculated. Disease-free and overall survivals were estimated by the Kaplan-Meier method and the Cox proportional hazards model was used to control for prognostic variables.Findings SBRT was safely delivered, with 49 (98% of 50 patients completing three prescribed fractions. The most frequent grade 2 or higher adverse events attributed to SBRT included fatigue (16%, nausea (8% and diarrhea (4%. One (2% grade 4 hyperbilirubinemia occurred. SBRT target response was 96% (48 of 50 patients. A 6-month clinical benefit was recorded in 34 (68% [95% CI, 53.2, 80.1] patients. No SBRT-targeted disease progressed. Non-radiosurgical disease relapse occurred in 31 (62% patients. Median disease-free survival was 7.8 months (95% CI, 4.0, 11.6. Median overall survival was 20.2 months (95% CI, 10.9, 29.5.Interpretation SBRT safely controlled metastatic gynecologic cancer targets. Given an observed high rate of non-radiosurgical disease relapse, a phase I trial assessing co-administration of SBRT and cytotoxic chemotherapy is underway.Funding Case Comprehensive Cancer Center

  16. Phase II Clinical Trial of Robotic Stereotactic Body Radiosurgery for Metastatic Gynecologic Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Kunos, Charles A.; Brindle, James [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University, School of Medicine, Cleveland, OH (United States); Waggoner, Steven; Zanotti, Kristine; Resnick, Kimberly; Fusco, Nancy; Adams, Ramon; Debernardo, Robert, E-mail: charles.kunos@uhhospitals.org [Division of Gynecologic Oncology, Department of Obstetrics and Gynecology, University Hospitals Case Medical Center and Case Western Reserve University, School of Medicine, Cleveland, OH (United States)

    2012-12-05

    Background: Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT) in women with metastatic gynecologic cancers. Methods: A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4) metastases underwent robotic-armed Cyberknife SBRT (24Gy/3 daily doses). Toxicities were graded prospectively by common toxicity criteria for adverse events (version 4.0). SBRT target responses were recorded following RECIST criteria (version 1.0). Rates of clinical benefit for SBRT and non-radiosurgical disease relapse were calculated. Disease-free and overall survivals were estimated by the Kaplan–Meier method and the Cox proportional hazards model was used to control for prognostic variables. Findings: SBRT was safely delivered, with 49 (98%) of 50 patients completing three prescribed fractions. The most frequent grade 2 or higher adverse events attributed to SBRT included fatigue (16%), nausea (8%), and diarrhea (4%). One (2%) grade four hyperbilirubinemia occurred. SBRT target response was 96% (48 of 50 patients). A 6-month clinical benefit was recorded in 34 [68% (95% CI, 53.2, 80.1)] patients. No SBRT targeted disease progressed. Non-radiosurgical disease relapse occurred in 31 (62%) patients. Median disease-free survival was 7.8 months (95% CI, 4.0, 11.6). Median overall survival was 20.2 months (95% CI, 10.9, 29.5). Interpretation: SBRT safely controlled metastatic gynecologic cancer targets. Given an observed high rate of non-radiosurgical disease relapse, a phase I trial assessing co-administration of SBRT and cytotoxic chemotherapy is underway. Funding: Case Comprehensive Cancer Center.

  17. Phase II Clinical Trial of Robotic Stereotactic Body Radiosurgery for Metastatic Gynecologic Malignancies

    International Nuclear Information System (INIS)

    Kunos, Charles A.; Brindle, James; Waggoner, Steven; Zanotti, Kristine; Resnick, Kimberly; Fusco, Nancy; Adams, Ramon; Debernardo, Robert

    2012-01-01

    Background: Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT) in women with metastatic gynecologic cancers. Methods: A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4) metastases underwent robotic-armed Cyberknife SBRT (24Gy/3 daily doses). Toxicities were graded prospectively by common toxicity criteria for adverse events (version 4.0). SBRT target responses were recorded following RECIST criteria (version 1.0). Rates of clinical benefit for SBRT and non-radiosurgical disease relapse were calculated. Disease-free and overall survivals were estimated by the Kaplan–Meier method and the Cox proportional hazards model was used to control for prognostic variables. Findings: SBRT was safely delivered, with 49 (98%) of 50 patients completing three prescribed fractions. The most frequent grade 2 or higher adverse events attributed to SBRT included fatigue (16%), nausea (8%), and diarrhea (4%). One (2%) grade four hyperbilirubinemia occurred. SBRT target response was 96% (48 of 50 patients). A 6-month clinical benefit was recorded in 34 [68% (95% CI, 53.2, 80.1)] patients. No SBRT targeted disease progressed. Non-radiosurgical disease relapse occurred in 31 (62%) patients. Median disease-free survival was 7.8 months (95% CI, 4.0, 11.6). Median overall survival was 20.2 months (95% CI, 10.9, 29.5). Interpretation: SBRT safely controlled metastatic gynecologic cancer targets. Given an observed high rate of non-radiosurgical disease relapse, a phase I trial assessing co-administration of SBRT and cytotoxic chemotherapy is underway. Funding: Case Comprehensive Cancer Center.

  18. Pure robotic retrocaval ureter repair

    Directory of Open Access Journals (Sweden)

    Ashok k. Hemal

    2008-12-01

    Full Text Available PURPOSE: To demonstrate the feasibility of pure robotic retrocaval ureter repair. MATERIALS AND METHODS: A 33 year old female presented with right loin pain and obstruction on intravenous urography with the classical "fish-hook" appearance. She was counseled on the various methods of repair and elected to have a robot assisted repair. The following steps are performed during a pure robotic retrocaval ureter repair. The patient is placed in a modified flank position, pneumoperitoneum created and ports inserted. The colon is mobilized to expose the retroperitoneal structures: inferior vena cava, right gonadal vein, right ureter, and duodenum. The renal pelvis and ureter are mobilized and the renal pelvis transected. The ureter is transposed anterior to the inferior vena cava and a pyelopyelostomy is performed over a JJ stent. RESULTS: This patient was discharged on postoperative day 3. The catheter and drain tube were removed on day 1. Her JJ stent was removed at 6 weeks postoperatively. The postoperative intravenous urography at 3 months confirmed normal drainage of contrast medium. CONCLUSION: Pure robotic retrocaval ureter is a feasible procedure; however, there does not appear to be any great advantage over pure laparoscopy, apart from the ergonomic ease for the surgeon as well the simpler intracorporeal suturing.

  19. Association of Blood Fatty Acid Composition and Dietary Pattern with the Risk of Non-Alcoholic Fatty Liver Disease in Patients Who Underwent Cholecystectomy.

    Science.gov (United States)

    Shim, Poyoung; Choi, Dongho; Park, Yongsoon

    2017-01-01

    The relationship between diet and non-alcoholic fatty liver disease (NAFLD) in patients with gallstone disease and in those who have a high risk for NAFLD has not been investigated. This study was conducted to investigate the association between the risk of NAFLD and dietary pattern in patients who underwent cholecystectomy. Additionally, we assessed the association between erythrocyte fatty acid composition, a marker for diet, and the risk of NAFLD. Patients (n = 139) underwent liver ultrasonography to determine the presence of NAFLD before laparoscopic cholecystectomy, reported dietary intake using food frequency questionnaire, and were assessed for blood fatty acid composition. Fifty-eight patients were diagnosed with NAFLD. The risk of NAFLD was negatively associated with 2 dietary patterns: consuming whole grain and legumes and consuming fish, vegetables, and fruit. NAFLD was positively associated with the consumption of refined grain, meat, processed meat, and fried foods. Additionally, the risk of NAFLD was positively associated with erythrocyte levels of 16:0 and 18:2t, while it was negatively associated with 20:5n3, 22:5n3, and Omega-3 Index. The risk of NAFLD was negatively associated with a healthy dietary pattern of consuming whole grains, legumes, vegetables, fish, and fruit and with an erythrocyte level of n-3 polyunsaturated fatty acids rich in fish. © 2017 S. Karger AG, Basel.

  20. Robot engineering

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seul

    2006-02-15

    This book deals with robot engineering, giving descriptions of robot's history, current tendency of robot field, work and characteristic of industrial robot, essential merit and vector, application of matrix, analysis of basic vector, expression of Denavit-Hartenberg, robot kinematics such as forward kinematics, inverse kinematics, cases of MATLAB program, and motion kinematics, robot kinetics like moment of inertia, centrifugal force and coriolis power, and Euler-Lagrangian equation course plan, SIMULINK position control of robots.

  1. Robot engineering

    International Nuclear Information System (INIS)

    Jung, Seul

    2006-02-01

    This book deals with robot engineering, giving descriptions of robot's history, current tendency of robot field, work and characteristic of industrial robot, essential merit and vector, application of matrix, analysis of basic vector, expression of Denavit-Hartenberg, robot kinematics such as forward kinematics, inverse kinematics, cases of MATLAB program, and motion kinematics, robot kinetics like moment of inertia, centrifugal force and coriolis power, and Euler-Lagrangian equation course plan, SIMULINK position control of robots.

  2. A Perspective on Robotic Assistance for Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Nathan A. Netravali

    2013-01-01

    Full Text Available Knee arthroplasty is used to treat patients with degenerative joint disease of the knee to reduce pain and restore the function of the joint. Although patient outcomes are generally quite good, there are still a number of patients that are dissatisfied with their procedures. Aside from implant design which has largely become standard, surgical technique is one of the main factors that determine clinical results. Therefore, a lot of effort has gone into improving surgical technique including the use of computer-aided surgery. The latest generation of orthopedic surgical tools involves the use of robotics to enhance the surgeons’ abilities to install implants more precisely and consistently. This review presents an evolution of robot-assisted surgical systems for knee replacement with an emphasis on the clinical results available in the literature. Ever since various robotic-assistance systems were developed and used clinically worldwide, studies have demonstrated that these systems are as safe as and more accurate than conventional methods of manual implantation. Robotic surgical assistance will likely result in improved surgical technique and improved clinical results.

  3. Can robotic surgery be done efficiently while training residents?

    Science.gov (United States)

    Honaker, Michael Drew; Paton, Beverly L; Stefanidis, Dimitrios; Schiffern, Lynnette M

    2015-01-01

    Robotic surgery is a rapidly growing area in surgery. In an era of emphasis on cost reduction, the question becomes how do you train residents in robotic surgery? The aim of this study was to determine if there was a difference in operative time and complications when comparing general surgery residents learning robotic cholecystectomies to those learning standard laparoscopic cholecystectomies. A retrospective analysis of adult patients undergoing robotic and laparoscopic cholecystectomy by surgical residents between March 2013 and February 2014 was conducted. Demographic data, operative factors, length of stay (LOS), and complications were examined. Univariate and multivariate analyses were performed. The significance was set at p robotic cholecystectomy group and 40 in the laparoscopic group). Age, diagnosis, and American Society of Anesthesiologists score were not significantly different between groups. There was only 1 complication in the standard laparoscopic group in which a patient had to be taken back to surgery because of an incarcerated port site. LOS was significantly higher in the standard laparoscopic group (mean = 2.28) than in the robotic group (mean = 0.56; p robotic group (mean = 97.00 minutes; p = 0.4455). When intraoperative cholangiogram was evaluated, OR time was shorter in the robotic group. Robotic training in general surgery residency does not amount to extra OR time. LOS in our study was significantly longer in the standard laparoscopic group. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  4. Unplanned readmission following transoral robotic surgery.

    Science.gov (United States)

    Topf, Michael C; Vo, Amanda; Tassone, Patrick; Shumrick, Christopher; Luginbuhl, Adam; Cognetti, David M; Curry, Joseph M

    2017-12-01

    To determine the rate of unplanned readmission after transoral robotic surgery (TORS), and to determine which patient or surgical factors increase the likelihood of readmission. Retrospective chart review of all patients who underwent TORS for squamous cell carcinoma at our institution from March 2010 through July 2016. Primary outcome was unplanned readmission to the hospital within 30 days of discharge. Univariable and multivariable logistic regression were performed to identify risk factors for unplanned readmission. 297 patients met eligibility criteria. 23 patients (7.7%) had unplanned readmissions within 30 days. Most common reasons for readmission were oropharyngeal bleed (n = 13) and pain/dehydration (n = 10). Average time to unplanned readmission was 6.52 days (range 0-25 days). Discharge on clopidogrel was the only variable independently associated with an increased risk of 30-day unplanned readmission on multivariable analysis with an OR = 6.85 (95% CI 1.59-26.36). Unplanned return to the operating room during initial hospitalization (OR = 7.55, 95% CI 1.26-38.50) and discharge on clopidogrel (OR = 10.45, 95% CI 1.06-82.69) were associated with increased risk of postoperative bleeding. Bilateral neck dissection (OR = 5.17, 95% CI 1.15-23.08) was associated with significantly increased odds of unplanned readmission secondary to pain and dehydration. Unplanned readmission following TORS occurs in a small but significant number of patients. Oropharyngeal bleeding and dehydration were the most common reasons for unplanned readmission following TORS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Robotic nurse duties in the urology operative room: 11 years of experience

    Directory of Open Access Journals (Sweden)

    Ali Abdel Raheem

    2017-04-01

    Full Text Available The robotic nurse plays an essential role in a successful robotic surgery. As part of the robotic surgical team, the robotic nurse must demonstrate a high level of professional knowledge, and be an expert in robotic technology and dealing with robotic malfunctions. Each one of the robotic nursing team “nurse coordinator, scrub-nurse and circulating-nurse” has a certain job description to ensure maximum patient's safety and robotic surgical efficiency. Well-structured training programs should be offered to the robotic nurse to be well prepared, feel confident, and maintain high-quality of care.

  6. Advancements in robotic-assisted thoracic surgery.

    Science.gov (United States)

    Steenwyk, Brad; Lyerly, Ralph

    2012-12-01

    Advancements in robotic-assisted thoracic surgery present potential advantages for patients as well as new challenges for the anesthesia and surgery teams. This article describes the major aspects of the surgical approach for the most commonly performed robotic-assisted thoracic surgical procedures as well as the pertinent preoperative, intraoperative, and postoperative anesthetic concerns. Copyright © 2012. Published by Elsevier Inc.

  7. Robotics in Arthroplasty: A Comprehensive Review.

    Science.gov (United States)

    Jacofsky, David J; Allen, Mark

    2016-10-01

    Robotic-assisted orthopedic surgery has been available clinically in some form for over 2 decades, claiming to improve total joint arthroplasty by enhancing the surgeon's ability to reproduce alignment and therefore better restore normal kinematics. Various current systems include a robotic arm, robotic-guided cutting jigs, and robotic milling systems with a diversity of different navigation strategies using active, semiactive, or passive control systems. Semiactive systems have become dominant, providing a haptic window through which the surgeon is able to consistently prepare an arthroplasty based on preoperative planning. A review of previous designs and clinical studies demonstrate that these robotic systems decrease variability and increase precision, primarily focusing on component positioning and alignment. Some early clinical results indicate decreased revision rates and improved patient satisfaction with robotic-assisted arthroplasty. The future design objectives include precise planning and even further improved consistent intraoperative execution. Despite this cautious optimism, many still wonder whether robotics will ultimately increase cost and operative time without objectively improving outcomes. Over the long term, every industry that has seen robotic technology be introduced, ultimately has shown an increase in production capacity, improved accuracy and precision, and lower cost. A new generation of robotic systems is now being introduced into the arthroplasty arena, and early results with unicompartmental knee arthroplasty and total hip arthroplasty have demonstrated improved accuracy of placement, improved satisfaction, and reduced complications. Further studies are needed to confirm the cost effectiveness of these technologies. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Calibration of Robot Reference Frames for Enhanced Robot Positioning Accuracy

    OpenAIRE

    Cheng, Frank Shaopeng

    2008-01-01

    This chapter discussed the importance and methods of conducting robot workcell calibration for enhancing the accuracy of the robot TCP positions in industrial robot applications. It shows that the robot frame transformations define the robot geometric parameters such as joint position variables, link dimensions, and joint offsets in an industrial robot system. The D-H representation allows the robot designer to model the robot motion geometry with the four standard D-H parameters. The robot k...

  9. In vivo demonstration of surgical task assistance using miniature robots.

    Science.gov (United States)

    Hawks, Jeff A; Kunowski, Jacob; Platt, Stephen R

    2012-10-01

    Laparoscopy is beneficial to patients as measured by less painful recovery and an earlier return to functional health compared to conventional open surgery. However, laparoscopy requires the manipulation of long, slender tools from outside the patient's body. As a result, laparoscopy generally benefits only patients undergoing relatively simple procedures. An innovative approach to laparoscopy uses miniature in vivo robots that fit entirely inside the abdominal cavity. Our previous work demonstrated that a mobile, wireless robot platform can be successfully operated inside the abdominal cavity with different payloads (biopsy, camera, and physiological sensors). We hope that these robots are a step toward reducing the invasiveness of laparoscopy. The current study presents design details and results of laboratory and in vivo demonstrations of several new payload designs (clamping, cautery, and liquid delivery). Laboratory and in vivo cooperation demonstrations between multiple robots are also presented.

  10. Robotic single port cholecystectomy: current data and future perspectives.

    Science.gov (United States)

    Angelou, Anastasios; Skarmoutsos, Athanasios; Margonis, Georgios A; Moris, Demetrios; Tsigris, Christos; Pikoulis, Emmanouil

    2017-04-01

    Minimally invasive techniques are used more and more frequently. Since conventional laparoscopic approach has been the gold standard, surgeons in their effort to further reduce the invasiveness of conventional laparoscopic cholecystectomy have adopted Single Incision approach. The widespread adoption of robotics has led to the inevitable hybridization of robotic technology with laparoendoscopic single-site surgery (LESS). As a result, employment of the da Vinci surgical system may allow greater surgical maneuverability, improving ergonomics. A review of the English literature was conducted to evaluate all robotic single port cholecystectomy performed till today. Demographic data, operative parameters, postoperative outcomes and materials used for the operation were collected and assessed. A total of 12 studies, including 501 patients were analyzed. Demographics and clinical characteristics of the patients was heterogeneous, but in most studies a mean BMI port cholecystectomy is a safe and feasible alternative to conventional multiport laparoscopic or manual robotic approach. However, current data do not suggest a superiority of robotic SILC over other established methods.

  11. Outcomes of infants undergoing robot-assisted laparoscopic pyeloplasty compared to open repair.

    Science.gov (United States)

    Dangle, Pankaj P; Kearns, James; Anderson, Blake; Gundeti, Mohan S

    2013-12-01

    Robotic surgery has evolved from simple extirpative surgery to complex reconstructions even in infants. Data are lacking comparing surgical and direct costs to open approaches. We describe the feasibility, salient tips and outcomes of robot-assisted laparoscopic pyeloplasty compared to an open approach. We evaluated patients undergoing open pyeloplasty or robot-assisted laparoscopic pyeloplasty. Ten patients in each group met inclusion criteria. Mean patient age was 3.31 months in the open group and 7.3 months in the robotic group (p=0.02). Postoperative outcomes including length of stay (2.2 vs 2.1 days), estimated blood loss (6.5 vs 7.6 ml), days to regular diet (1 vs 1.1) and days to Foley catheter removal (1.3 vs 1.3) were similar between the open and robotic groups. Total operating time (199 vs 242 minutes) was significantly longer in the robotic group. Postoperative improvement in hydronephrosis was identical in both groups. Direct costs, excluding amortization, robotic cost, maintenance and depreciation, were $4,410 in the open group and $4,979 in the robotic group (p=0.10). In our preliminary experience robotic pyeloplasty in infants is feasible and safe. The immediate outcomes are similar to those of an open approach. The robotic technique in infants currently has the benefits of improved esthetic appearance, improved pain control and similar direct costs compared to the traditional open approach. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. MODULAR MANIPULATOR FOR ROBOTICS APPLICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Joseph W. Geisinger, Ph.D.

    2001-07-31

    ARM Automation, Inc. is developing a framework of modular actuators that can address the DOE's wide range of robotics needs. The objective of this effort is to demonstrate the effectiveness of this technology by constructing a manipulator from these actuators within a glovebox for Automated Plutonium Processing (APP). At the end of the project, the system of actuators was used to construct several different manipulator configurations, which accommodate common glovebox tasks such as repackaging. The modular nature and quickconnects of this system simplify installation into ''hot'' boxes and any potential modifications or repair therein. This work focused on the development of self-contained robotic actuator modules including the embedded electronic controls for the purpose of building a manipulator system. Both of the actuators developed under this project contain the control electronics, sensors, motor, gear train, wiring, system communications and mechanical interfaces of a complete robotics servo device. Test actuators and accompanying DISC{trademark}s underwent validation testing at The University of Texas at Austin and ARM Automation, Inc. following final design and fabrication. The system also included custom links, an umbilical cord, an open architecture PC-based system controller, and operational software that permitted integration into a completely functional robotic manipulator system. The open architecture on which this system is based avoids proprietary interfaces and communication protocols which only serve to limit the capabilities and flexibility of automation equipment. The system was integrated and tested in the contractor's facility for intended performance and operations. The manipulator was tested using the full-scale equipment and process mock-ups. The project produced a practical and operational system including a quantitative evaluation of its performance and cost.

  13. The role of robotic surgical system in the management of vascular disease.

    Science.gov (United States)

    Lin, Judith C

    2013-10-01

    The evolution of minimally invasive treatment for aneurysms and occlusive disease has led to the development of endovascular, laparoscopic, and robot-assisted techniques. This article reviews the current literature on the clinical use of robotic surgical systems in the treatment of patients with aneurysms and occlusive disease. A MEDLINE search was performed using the keywords "robotic, vascular, AND surgery." All pertinent articles concerning the use of the robotic surgical system on aneurysms and occlusive disease were reviewed. The author's personal experience consisted of a retrospective review of a prospectively maintained confidential database on all procedures performed with the da Vinci(®) surgical system. Several robot-assisted laparoscopic series on the treatment of aortic disease were identified, including review articles of potential clinical applications in hybrid, laparoscopic vascular, and endovascular treatments for vascular patients using robotic technology. The use of computer-enhanced or robotic technology as a sole modality for bypass of occlusive disease and repair of abdominal aortic, splenic, and renal aneurysms was described in case series with satisfactory patient outcomes. Current robotic endovascular technology was also described. Minimally invasive techniques using endovascular, laparoscopic, or robot-assisted technology have revolutionized the treatment of aortoiliac, splanchnic, and renal aneurysms and occlusive disease. However, robot-assisted techniques for aortic disease may involve a learning curve and increased operating times. Although endovascular therapy is preferred because of faster recovery, this preference for improved short-term outcomes will be balanced with the superiority and durability of robot-assisted endoscopic methods as comparable to open surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. The use of robotics in surgery: a review.

    Science.gov (United States)

    Hussain, A; Malik, A; Halim, M U; Ali, A M

    2014-11-01

    There is an ever-increasing drive to improve surgical patient outcomes. Given the benefits which robotics has bestowed upon a wide range of industries, from vehicle manufacturing to space exploration, robots have been highlighted by many as essential for continued improvements in surgery. The goal of this review is to outline the history of robotic surgery, and detail the key studies which have investigated its effects on surgical outcomes. Issues of cost-effectiveness and patient acceptability will also be discussed. Robotic surgery has been shown to shorten hospital stays, decrease complication rates and allow surgeons to perform finer tasks, when compared to the traditional laparoscopic and open approaches. These benefits, however, must be balanced against increased intraoperative times, vast financial costs and the increased training burden associated with robotic techniques. The outcome of such a cost-benefit analysis appears to vary depending on the procedure being conducted; indeed the strongest evidence in favour of its use comes from the fields of urology and gynaecology. It is hoped that with the large-scale, randomised, prospective clinical trials underway, and an ever-expanding research base, many of the outstanding questions surrounding robotic surgery will be answered in the near future. © 2014 John Wiley & Sons Ltd.

  15. Retention of fundamental surgical skills learned in robot-assisted surgery.

    Science.gov (United States)

    Suh, Irene H; Mukherjee, Mukul; Shah, Bhavin C; Oleynikov, Dmitry; Siu, Ka-Chun

    2012-12-01

    Evaluation of the learning curve for robotic surgery has shown reduced errors and decreased task completion and training times compared with regular laparoscopic surgery. However, most training evaluations of robotic surgery have only addressed short-term retention after the completion of training. Our goal was to investigate the amount of surgical skills retained after 3 months of training with the da Vinci™ Surgical System. Seven medical students without any surgical experience were recruited. Participants were trained with a 4-day training program of robotic surgical skills and underwent a series of retention tests at 1 day, 1 week, 1 month, and 3 months post-training. Data analysis included time to task completion, speed, distance traveled, and movement curvature by the instrument tip. Performance of the participants was graded using the modified Objective Structured Assessment of Technical Skills (OSATS) for robotic surgery. Participants filled out a survey after each training session by answering a set of questions. Time to task completion and the movement curvature was decreased from pre- to post-training and the performance was retained at all the corresponding retention periods: 1 day, 1 week, 1 month, and 3 months. The modified OSATS showed improvement from pre-test to post-test and this improvement was maintained during all the retention periods. Participants increased in self-confidence and mastery in performing robotic surgical tasks after training. Our novel comprehensive training program improved robot-assisted surgical performance and learning. All trainees retained their fundamental surgical skills for 3 months after receiving the training program.

  16. Automated dental implantation using image-guided robotics: registration results.

    Science.gov (United States)

    Sun, Xiaoyan; McKenzie, Frederic D; Bawab, Sebastian; Li, Jiang; Yoon, Yongki; Huang, Jen-K

    2011-09-01

    One of the most important factors affecting the outcome of dental implantation is the accurate insertion of the implant into the patient's jaw bone, which requires a high degree of anatomical accuracy. With the accuracy and stability of robots, image-guided robotics is expected to provide more reliable and successful outcomes for dental implantation. Here, we proposed the use of a robot for drilling the implant site in preparation for the insertion of the implant. An image-guided robotic system for automated dental implantation is described in this paper. Patient-specific 3D models are reconstructed from preoperative Cone-beam CT images, and implantation planning is performed with these virtual models. A two-step registration procedure is applied to transform the preoperative plan of the implant insertion into intra-operative operations of the robot with the help of a Coordinate Measurement Machine (CMM). Experiments are carried out with a phantom that is generated from the patient-specific 3D model. Fiducial Registration Error (FRE) and Target Registration Error (TRE) values are calculated to evaluate the accuracy of the registration procedure. FRE values are less than 0.30 mm. Final TRE values after the two-step registration are 1.42 ± 0.70 mm (N = 5). The registration results of an automated dental implantation system using image-guided robotics are reported in this paper. Phantom experiments show that the practice of robot in the dental implantation is feasible and the system accuracy is comparable to other similar systems for dental implantation.

  17. Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience

    International Nuclear Information System (INIS)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong; Goh, Khean Lee; Yoong, Boon Koon; Ho, Gwo Fuang; Yim, Carolyn Chue Wai; Kulkarni, Anjali

    2014-01-01

    Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles. We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions). Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff. (orig.)

  18. Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Basri Johan Jeet [University of Malaya, Department of Biomedical Imaging, Faculty of Medicine, Kuala Lumpur (Malaysia); Yeong, Chai Hong [University of Malaya, University of Malaya Research Imaging Centre, Faculty of Medicine, Kuala Lumpur (Malaysia); Goh, Khean Lee [University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Yoong, Boon Koon [University of Malaya, Department of Surgery, Faculty of Medicine, Kuala Lumpur (Malaysia); Ho, Gwo Fuang [University of Malaya, Department of Oncology, Faculty of Medicine, Kuala Lumpur (Malaysia); Yim, Carolyn Chue Wai [University of Malaya, Department of Anesthesia, Faculty of Medicine, Kuala Lumpur (Malaysia); Kulkarni, Anjali [Perfint Healthcare Corporation, Florence, OR (United States)

    2014-01-15

    Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles. We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions). Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff. (orig.)

  19. 65. Impact of focused echocardiography in clinical decision of patients presented with STMI, underwent primary percutenouse angioplasty

    Directory of Open Access Journals (Sweden)

    M. Qasem

    2016-07-01

    Full Text Available Echocardiography in coronary artery diseases is an essential, routine echocardiography prior to primary percutaneous angioplasty is not clear. In our clinical practice in primary angioplasty we faced lots of complications either before or during or after the procedure. Moreover, lots of incidental findings that discovered after the procedure which if known will affect the plan of management. One-hundred-nineteen consecutive underwent primary angioplasty. All patients underwent FE prior to the procedure in catheterization lab while the patient was preparing for the procedure. FE with 2DE of LV at base, mid and apex, and apical stander views. Diastology grading, E/E′ and color doppler of mitral and aortic valve were performed. (N = 119 case of STMI were enrolled, mean age 51 ± 12 year. Eleven cases (9.2% had normal coronary and normal LV function. Twenty cases (17% of MI complication detected before the procedures: RV infarction 8.4% (5.1% asymptomatic and 3.3% symptomatic, ischemic MR (8.4%, LV apical aneurysm (0.8%, significant pericardial effusion (0.80%. Acute pulmonary edema in 17 cases (14.3%: six cases (5.1% developed acute pulmonary edema on the cath lab with grade 3 diastolic dysfunction and E/E ′  >20, 9 cases (7.6% develop acute pulmonary edema in CCU with grade 2–3 diastolic dysfunction and E/E′ 15–20. 2 cases (2.7% develop acute pulmonary in CCU with grade 1–2 diastolic dysfunction and E/E′ 9–14. One case (0.8% presented cardiac tamponade 2 h post PCI. Incidental finding not related to STMI were as follow: 2 cases (1.7% with severe fibro degenerative MR, 2 cases (1.7% with mild to moderate AR and 2 cases (1.7% with mild to moderate AS. Isoled CABG 5/4.2% and CABG and MVR 2/1.7%. FE play an important role in guiding the management, early detection the incidental findings and complication post PCI.

  20. Generic robot architecture

    Science.gov (United States)

    Bruemmer, David J [Idaho Falls, ID; Few, Douglas A [Idaho Falls, ID

    2010-09-21

    The present invention provides methods, computer readable media, and apparatuses for a generic robot architecture providing a framework that is easily portable to a variety of robot platforms and is configured to provide hardware abstractions, abstractions for generic robot attributes, environment abstractions, and robot behaviors. The generic robot architecture includes a hardware abstraction level and a robot abstraction level. The hardware abstraction level is configured for developing hardware abstractions that define, monitor, and control hardware modules available on a robot platform. The robot abstraction level is configured for defining robot attributes and provides a software framework for building robot behaviors from the robot attributes. Each of the robot attributes includes hardware information from at least one hardware abstraction. In addition, each robot attribute is configured to substantially isolate the robot behaviors from the at least one hardware abstraction.

  1. Molecular Robots Obeying Asimov's Three Laws of Robotics.

    Science.gov (United States)

    Kaminka, Gal A; Spokoini-Stern, Rachel; Amir, Yaniv; Agmon, Noa; Bachelet, Ido

    2017-01-01

    Asimov's three laws of robotics, which were shaped in the literary work of Isaac Asimov (1920-1992) and others, define a crucial code of behavior that fictional autonomous robots must obey as a condition for their integration into human society. While, general implementation of these laws in robots is widely considered impractical, limited-scope versions have been demonstrated and have proven useful in spurring scientific debate on aspects of safety and autonomy in robots and intelligent systems. In this work, we use Asimov's laws to examine these notions in molecular robots fabricated from DNA origami. We successfully programmed these robots to obey, by means of interactions between individual robots in a large population, an appropriately scoped variant of Asimov's laws, and even emulate the key scenario from Asimov's story "Runaround," in which a fictional robot gets into trouble despite adhering to the laws. Our findings show that abstract, complex notions can be encoded and implemented at the molecular scale, when we understand robots on this scale on the basis of their interactions.

  2. Transversus abdominis plane (TAP) block after robot-assisted laparoscopic hysterectomy

    DEFF Research Database (Denmark)

    Torup, H; Bøgeskov, M; Hansen, E G

    2015-01-01

    BACKGROUND: Transversus abdominis plane (TAP) block is widely used as a part of pain management after various abdominal surgeries. We evaluated the effect of TAP block as an add-on to the routine analgesic regimen in patients undergoing robot-assisted laparoscopic hysterectomy. METHODS......: In a prospective blinded study, 70 patients scheduled for elective robot-assisted laparoscopic hysterectomy were randomised to receive either TAP block (ropivacaine 0.5%, 20 ml on each side) or sham block (isotonic saline 0.9%, 20 ml on each side). All patients had patient-controlled analgesia (PCA) with morphine...... and Nonsteroidal anti-inflammatory drugs (NSAID) treatment, had no effect on morphine consumption, VAS pain scores, or frequency of nausea and vomiting after robot-assisted laparoscopic hysterectomy compared with paracetamol and NSAID alone....

  3. Colias: An Autonomous Micro Robot for Swarm Robotic Applications

    Directory of Open Access Journals (Sweden)

    Farshad Arvin

    2014-07-01

    Full Text Available Robotic swarms that take inspiration from nature are becoming a fascinating topic for multi-robot researchers. The aim is to control a large number of simple robots in order to solve common complex tasks. Due to the hardware complexities and cost of robot platforms, current research in swarm robotics is mostly performed by simulation software. The simulation of large numbers of these robots in robotic swarm applications is extremely complex and often inaccurate due to the poor modelling of external conditions. In this paper, we present the design of a low-cost, open-platform, autonomous micro-robot (Colias for robotic swarm applications. Colias employs a circular platform with a diameter of 4 cm. It has a maximum speed of 35 cm/s which enables it to be used in swarm scenarios very quickly over large arenas. Long-range infrared modules with an adjustable output power allow the robot to communicate with its direct neighbours at a range of 0.5 cm to 2 m. Colias has been designed as a complete platform with supporting software development tools for robotics education and research. It has been tested in both individual and swarm scenarios, and the observed results demonstrate its feasibility for use as a micro-sized mobile robot and as a low-cost platform for robot swarm applications.

  4. Multiparametric magnetic resonance imaging and frozen-section analysis efficiently predict upgrading, upstaging, and extraprostatic extension in patients undergoing nerve-sparing robotic-assisted radical prostatectomy.

    Science.gov (United States)

    Bianchi, Roberto; Cozzi, Gabriele; Petralia, Giuseppe; Alessi, Sarah; Renne, Giuseppe; Bottero, Danilo; Brescia, Antonio; Cioffi, Antonio; Cordima, Giovanni; Ferro, Matteo; Matei, Deliu Victor; Mazzoleni, Federica; Musi, Gennaro; Mistretta, Francesco Alessandro; Serino, Alessandro; Tringali, Valeria Maria Lucia; Coman, Ioan; De Cobelli, Ottavio

    2016-10-01

    To evaluate the role of multiparametric magnetic resonance imaging (mpMRI) in predicting upgrading, upstaging, and extraprostatic extension in patients with low-risk prostate cancer (PCa). MpMRI may reduce positive surgical margins (PSM) and improve nerve-sparing during robotic-assisted radical prostatectomy (RARP) for localized prostate cancer PCa.This was a retrospective, monocentric, observational study. We retrieved the records of patients undergoing RARP from January 2012 to December 2013 at our Institution. Inclusion criteria were: PSA <10 ng/mL; clinical stage patients underwent nerve-sparing RARP. During surgery, the specimen was sent for FSA of the posterolateral aspects. The surgeon, according to the localization scheme provided by the mpMRI, inked the region of the posterolateral aspect of the prostate that had to be submitted to FSA.We evaluated association between clinical features and PSM, upgrading, upstaging, and presence of unfavorable disease.Two hundred fifty-four patients who underwent nerve-sparing RARP were included. PSM rate was 29.13% and 15.75% at FSA and final pathology respectively. Interestingly, the use of FSA reduced PSM rate in pT3 disease (25.81%). Higher PIRADS scores demonstrated to be related to high probability of upgrading and upstaging. This significativity remains even when considering PIRADS 2-3 versus 4 versus 5 and PIRADS 2-3 versus 4-5. Also PSM at FSA were associated with higher probability of upgrading and upstaging.PIRADS score and FSA resulted to be strictly related to grading and staging, thus being able to predict upgrading and/or upstaging at final pathology.

  5. Robot-assisted Partial Nephrectomy: 5-yr Oncological Outcomes at a Single European Tertiary Cancer Center.

    Science.gov (United States)

    Vartolomei, Mihai Dorin; Matei, Deliu Victor; Renne, Giuseppe; Tringali, Valeria Maria; Crisan, Nicolae; Musi, Gennaro; Mistretta, Francesco Alessandro; Russo, Andrea; Cozzi, Gabriele; Cordima, Giovani; Luzzago, Stefano; Cioffi, Antonio; Di Trapani, Ettore; Catellani, Michele; Delor, Maurizio; Bottero, Danilo; Imbimbo, Ciro; Mirone, Vincenzo; Ferro, Matteo; de Cobelli, Ottavio

    2017-10-27

    Nowadays, there is a debate about which surgical treatment should be best for clinical T1 renal tumors. If the oncological outcomes are considered, there are many open and laparoscopic series published. As far as robotic series are concerned, only a few of them report 5-yr oncological outcomes. The aim of this study was to analyze robot-assisted partial nephrectomy (RAPN) midterm oncological outcomes achieved in a tertiary robotic reference center. Between April 2009 and September 2013, 123 consecutive patients with clinical T1-stage renal masses underwent RAPN in our tertiary cancer center. Inclusion criteria were as follows: pathologically confirmed renal cell carcinomas (RCCs) and follow-up for >12 mo. Eighteen patients were excluded due to follow-up of <12 mo and 15 due to benign final pathology. Median follow-up was 59 mo (interquartile range 44-73 mo). Patients were followed according to guideline recommendations and institutional protocol. Outcomes were measured by time to disease progression, overall survival, or time to cancer-specific death. Kaplan-Meier method was used to estimate survival; log-rank tests were applied for pair-wise comparison of survival. From the 90 patients included, 66 (73.3%) had T1a, 12 (13.3%) T1b, three (3.3%) T2a, and nine (10%) T3a tumors. Predominant histological type was clear cell carcinoma: 67 (74.5%). Fuhrmann grade 1 and 2 was found in 73.3% of all malignant tumors. Two patients (2.2%) had positive surgical margins, and complication rate was 17.8%. Relapse rate was 7.7%, including two cases (2.2%) of local recurrences and five (5.5%) distant metastasis. Five-year disease-free survival was 90.9%, 5-yr cancer-specific survival was 97.5%, and 5-yr overall survival was 95.1%. Midterm oncological outcomes after RAPN for localized RCCs (predominantly T1a tumors of low anatomic complexity) were shown to be good, adding significant evidence to support the oncological efficacy and safety of RAPN for the treatment of this type of

  6. Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system.

    Science.gov (United States)

    Schuler, Patrick J; Hoffmann, Thomas K; Veit, Johannes A; Rotter, Nicole; Friedrich, Daniel T; Greve, Jens; Scheithauer, Marc O

    2017-06-01

    Total laryngectomy is a standard procedure in head-and-neck surgery for the treatment of cancer patients. Recent clinical experiences have indicated a clinical benefit for patients undergoing transoral robot-assisted total laryngectomy (TORS-TL) with commercially available systems. Here, a new hybrid procedure for total laryngectomy is presented. TORS-TL was performed in human cadavers (n = 3) using a transoral-transcervical hybrid procedure. The transoral approach was performed with a robotic flexible robot-assisted surgical system (Flex®) and compatible flexible instruments. Transoral access and visualization of anatomical landmarks were studied in detail. Total laryngectomy is feasible with a combined transoral-transcervical approach using the flexible robot-assisted surgical system. Transoral visualization of all anatomical structures is sufficient. The flexible design of the robot is advantageous for transoral surgery of the laryngeal structures. Transoral robot assisted surgery has the potential to reduce morbidity, hospital time and fistula rates in a selected group of patients. Initial clinical studies and further development of supplemental tools are in progress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Imaging-guided thoracoscopic resection of a ground-glass opacity lesion in a hybrid operating room equipped with a robotic C-arm CT system.

    Science.gov (United States)

    Hsieh, Chen-Ping; Hsieh, Ming-Ju; Fang, Hsin-Yueh; Chao, Yin-Kai

    2017-05-01

    The intraoperative identification of small pulmonary nodules through video-assisted thoracoscopic surgery remains challenging. Although preoperative CT-guided nodule localization is commonly used to detect tumors during video-assisted thoracoscopic surgery (VATS), this approach carries inherent risks. We report the case of a patient with stage I lung cancer presenting as an area of ground-glass opacity (GGO) in the right upper pulmonary lobe. He successfully underwent a single-stage, CT-guided localization and removal of the pulmonary nodule within a hybrid operating room (OR) equipped with a robotic C-arm.

  8. External force/velocity control for an autonomous rehabilitation robot

    Science.gov (United States)

    Saekow, Peerayuth; Neranon, Paramin; Smithmaitrie, Pruittikorn

    2018-01-01

    Stroke is a primary cause of death and the leading cause of permanent disability in adults. There are many stroke survivors, who live with a variety of levels of disability and always need rehabilitation activities on daily basis. Several studies have reported that usage of rehabilitation robotic devices shows the better improvement outcomes in upper-limb stroke patients than the conventional therapy-nurses or therapists actively help patients with exercise-based rehabilitation. This research focuses on the development of an autonomous robotic trainer designed to guide a stroke patient through an upper-limb rehabilitation task. The robotic device was designed and developed to automate the reaching exercise as mentioned. The designed robotic system is made up of a four-wheel omni-directional mobile robot, an ATI Gamma multi-axis force/torque sensor used to measure contact force and a microcontroller real-time operating system. Proportional plus Integral control was adapted to control the overall performance and stability of the autonomous assistive robot. External force control was successfully implemented to establish the behavioral control strategy for the robot force and velocity control scheme. In summary, the experimental results indicated satisfactorily stable performance of the robot force and velocity control can be considered acceptable. The gain tuning for proportional integral (PI) velocity control algorithms was suitably estimated using the Ziegler-Nichols method in which the optimized proportional and integral gains are 0.45 and 0.11, respectively. Additionally, the PI external force control gains were experimentally tuned using the trial and error method based on a set of experiments which allow a human participant moves the robot along the constrained circular path whilst attempting to minimize the radial force. The performance was analyzed based on the root mean square error (E_RMS) of the radial forces, in which the lower the variation in radial

  9. Rehabilitation robotics for the upper extremity: review with new directions for orthopaedic disorders.

    Science.gov (United States)

    Hakim, Renée M; Tunis, Brandon G; Ross, Michael D

    2017-11-01

    The focus of research using technological innovations such as robotic devices has been on interventions to improve upper extremity function in neurologic populations, particularly patients with stroke. There is a growing body of evidence describing rehabilitation programs using various types of supportive/assistive and/or resistive robotic and virtual reality-enhanced devices to improve outcomes for patients with neurologic disorders. The most promising approaches are task-oriented, based on current concepts of motor control/learning and practice-induced neuroplasticity. Based on this evidence, we describe application and feasibility of virtual reality-enhanced robotics integrated with current concepts in orthopaedic rehabilitation shifting from an impairment-based focus to inclusion of more intense, task-specific training for patients with upper extremity disorders, specifically emphasizing the wrist and hand. The purpose of this paper is to describe virtual reality-enhanced rehabilitation robotic devices, review evidence of application in patients with upper extremity deficits related to neurologic disorders, and suggest how this technology and task-oriented rehabilitation approach can also benefit patients with orthopaedic disorders of the wrist and hand. We will also discuss areas for further research and development using a task-oriented approach and a commercially available haptic robotic device to focus on training of grasp and manipulation tasks. Implications for Rehabilitation There is a growing body of evidence describing rehabilitation programs using various types of supportive/assistive and/or resistive robotic and virtual reality-enhanced devices to improve outcomes for patients with neurologic disorders. The most promising approaches using rehabilitation robotics are task-oriented, based on current concepts of motor control/learning and practice-induced neuroplasticity. Based on the evidence in neurologic populations, virtual reality-enhanced robotics

  10. Perioperative and mid-term oncologic outcomes of robotic assisted radical cystectomy with totally intracorporeal neobladder: Results of a propensity score matched comparison with open cohort from a single-centre series.

    Science.gov (United States)

    Simone, Giuseppe; Tuderti, Gabriele; Misuraca, Leonardo; Anceschi, Umberto; Ferriero, Mariaconsiglia; Minisola, Francesco; Guaglianone, Salvatore; Gallucci, Michele

    2018-04-17

    In this study, we compared perioperative and oncologic outcomes of patients treated with either open or robot-assisted radical cystectomy and intracorporeal neobladder at a tertiary care center. The institutional prospective bladder cancer database was queried for "cystectomy with curative intent" and "neobladder". All patients underwent robot-assisted radical cystectomy and intracorporeal neobladder or open radical cystectomy and orthotopic neobladder for high-grade non-muscle invasive bladder cancer or muscle invasive bladder cancer with a follow-up length ≥2 years were included. A 1:1 propensity score matching analysis was used. Kaplan-Meier method was performed to compare oncologic outcomes of selected cohorts. Survival rates were computed at 1,2,3 and 4 years after surgery and the log rank test was applied to assess statistical significance between the matched groups. Overall, 363 patients (299 open and 64 robotic) were included. Open radical cystectomy patients were more frequently male (p = 0.08), with higher pT stages (p = 0.003), lower incidence of urothelial histologies (p = 0.05) and lesser adoption of neoadjuvant chemotherapy (open radical cystectomy cases (all p ≥ 0.22). Open cohort showed a higher rate of perioperative overall complications (91.3% vs 42.2%, p 0.001). At Kaplan-Meier analysis robotic and open cohorts displayed comparable disease-free survival (log-rank p = 0.746), cancer-specific survival (p = 0.753) and overall-survival rates (p = 0.909). Robot-assisted radical cystectomy and intracorporeal neobladder provides comparable oncologic outcomes of open radical cystectomy and orthotopic neobladder at intermediate term survival analysis. Copyright © 2018 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  11. Micro intelligence robot

    International Nuclear Information System (INIS)

    Jeon, Yon Ho

    1991-07-01

    This book gives descriptions of micro robot about conception of robots and micro robot, match rules of conference of micro robots, search methods of mazes, and future and prospect of robots. It also explains making and design of 8 beat robot like making technique, software, sensor board circuit, and stepping motor catalog, speedy 3, Mr. Black and Mr. White, making and design of 16 beat robot, such as micro robot artist, Jerry 2 and magic art of shortening distances algorithm of robot simulation.

  12. Transoral robotic surgery in head and neck cancer.

    Science.gov (United States)

    Hans, S; Delas, B; Gorphe, P; Ménard, M; Brasnu, D

    2012-02-01

    Robots have invaded industry and, more recently, the field of medicine. Following the development of various prototypes, Intuitive Surgical® has developed the Da Vinci surgical robot. This robot, designed for abdominal surgery, has been widely used in urology since 2000. The many advantages of this transoral robotic surgery (TORS) are described in this article. Its disadvantages are essentially its high cost and the absence of tactile feedback. The first feasibility studies in head and neck cancer, conducted in animals, dummies and cadavers, were performed in 2005, followed by the first publications in patients in 2006. The first series including more than 20 patients treated by TORS demonstrated the feasibility for the following sites: oropharynx, supraglottic larynx and hypopharynx. However, these studies did not validate the oncological results of the TORS technique. TORS decreases the number of tracheotomies, and allows more rapid swallowing rehabilitation and a shorter length of hospital stay. Technical improvements are expected. Smaller, more ergonomic, new generation robots, therefore more adapted to the head and neck, will probably be available in the future. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  13. Outcomes of robot-assisted simple enucleation of renal masses: A single European center experience.

    Science.gov (United States)

    Matei, Deliu Victor; Vartolomei, Mihai Dorin; Musi, Gennaro; Renne, Giuseppe; Tringali, Valeria Maria Lucia; Mistretta, Francesco Alessandro; Delor, Maurizio; Russo, Andrea; Cioffi, Antonio; Bianchi, Roberto; Cozzi, Gabriele; Di Trapani, Ettore; Bottero, Danilo; Cordima, Giovanni; Lucarelli, Giuseppe; Ferro, Matteo; de Cobelli, Ottavio

    2017-05-01

    The aim of this study was to assess the ability of pre-and intraoperative parameters, to predict the risk of perioperative complications after robot-assisted laparoscopic simple enucleation (RASE) of renal masses, and to evaluate the rate of trifecta achievement of this approach stratifying the cohort according to the use of ischemia during the enucleation.From April 2009 to June 2016, 129 patients underwent RASE at our Institution. We stratified the procedures in 2 groups: clamping and clamp-less RASE. After RASE, all specimens were retrospectively reviewed to assess the surface-intermediate-base (SIB) scoring system. Patients were followed-up according to the European Association of Urology guidelines recommendations. All pre-, intra-, and postoperative outcomes were prospectively collected in a customized database and retrospectively analyzed.A total of 112 (86.8%) patients underwent a pure RASE and 17 (13.2%) had a hybrid according to SIB classification system. The mean age was 61.17 years. In 21 patients (16.3%), complications occurred, 13 (61.9%) were Clavien 1 and 2, while 8 were Clavien 3a and b complications. Statistical significant association with complications was found in patients with American Society of Anestesiology (ASA) score 3 (44.5%, P = .04), longer mean operative time (OT) 195 versus 161.36 minutes (P =.03), mean postoperative hemoglobin (Hb) 10.1 versus 11.8 (P 3, longer OT, and ΔHb. RASE is suitable for the clamp-less approach, which allows to perform easier the pure enucleation (SIB 0) and to obtain higher rates of trifecta outcomes.

  14. 'Trifecta' outcomes of robot-assisted partial nephrectomy in solitary kidney: a Vattikuti Collective Quality Initiative (VCQI) database analysis.

    Science.gov (United States)

    Arora, Sohrab; Abaza, Ronney; Adshead, James M; Ahlawat, Rajesh K; Challacombe, Benjamin J; Dasgupta, Prokar; Gandaglia, Giorgio; Moon, Daniel A; Yuvaraja, Thyavihally B; Capitanio, Umberto; Larcher, Alessandro; Porpiglia, Francesco; Porter, James R; Mottrie, Alexander; Bhandari, Mahendra; Rogers, Craig

    2018-01-01

    To analyse the outcomes of robot-assisted partial nephrectomy (RAPN) in patients with a solitary kidney in a large multi-institutional database. In all, 2755 patients in the Vattikuti Collective Quality Initiative database underwent RAPN by 22 surgeons at 14 centres in nine countries. Of these patients, 74 underwent RAPN with a solitary kidney between 2007 and 2016. We retrospectively analysed the functional and oncological outcomes of these 74 patients. A 'trifecta' of outcomes was assessed, with trifecta defined as a warm ischaemia time (WIT) of negative surgical margins, and no complications intraoperatively or within 3 months of RAPN. All 74 patients underwent RAPN successfully with one conversion to radical nephrectomy. The median (interquartile range [IQR]) operative time was 180 (142-230) min. Early unclamping was used in 11 (14.9%) patients and zero ischaemia was used in 12 (16.2%). Trifecta outcomes were achieved in 38 of 66 patients (57.6%). The median (IQR) WIT was 15.5 (8.75-20.0) min for the entire cohort. The overall complication rate was 24.1% and the rate of Clavien-Dindo grade ≤II complications was 16.3%. Positive surgical margins were present in four cases (5.4%). The median (IQR) follow-up was 10.5 (2.12-24.0) months. The median drop in estimated glomerular filtration rate at 3 months was 7.0 mL/min/1.72 m 2 (11.01%). Our findings suggest that RAPN is a safe and effective treatment option for select renal tumours in solitary kidneys in terms of a trifecta of negative surgical margins, WIT of <20 min, and low operative and perioperative morbidity. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  15. Robotic surgery in children: adopt now, await, or dismiss?

    Science.gov (United States)

    Cundy, Thomas P; Marcus, Hani J; Hughes-Hallett, Archie; Khurana, Sanjeev; Darzi, Ara

    2015-12-01

    The role of robot-assisted surgery in children remains controversial. This article aims to distil this debate into an evidence informed decision-making taxonomy; to adopt this technology (1) now, (2) later, or (3) not at all. Robot-assistance is safe, feasible and effective in selected cases as an adjunctive tool to enhance capabilities of minimally invasive surgery, as it is known today. At present, expectations of rigid multi-arm robotic systems to deliver higher quality care are over-estimated and poorly substantiated by evidence. Such systems are associated with high costs. Further comparative effectiveness evidence is needed to define the case-mix for which robot-assistance might be indicated. It seems unlikely that we should expect compelling patient benefits when it is only the mode of minimally invasive surgery that differs. Only large higher-volume institutions that share the robot amongst multiple specialty groups are likely to be able to sustain higher associated costs with today's technology. Nevertheless, there is great potential for next-generation surgical robotics to enable better ways to treat childhood surgical diseases through less invasive techniques that are not possible today. This will demand customized technology for selected patient populations or procedures. Several prototype robots exclusively designed for pediatric use are already under development. Financial affordability must be a high priority to ensure clinical accessibility.

  16. Modelling of industrial robot in LabView Robotics

    Science.gov (United States)

    Banas, W.; Cwikła, G.; Foit, K.; Gwiazda, A.; Monica, Z.; Sekala, A.

    2017-08-01

    Currently can find many models of industrial systems including robots. These models differ from each other not only by the accuracy representation parameters, but the representation range. For example, CAD models describe the geometry of the robot and some even designate a mass parameters as mass, center of gravity, moment of inertia, etc. These models are used in the design of robotic lines and sockets. Also systems for off-line programming use these models and many of them can be exported to CAD. It is important to note that models for off-line programming describe not only the geometry but contain the information necessary to create a program for the robot. Exports from CAD to off-line programming system requires additional information. These models are used for static determination of reachability points, and testing collision. It’s enough to generate a program for the robot, and even check the interaction of elements of the production line, or robotic cell. Mathematical models allow robots to study the properties of kinematic and dynamic of robot movement. In these models the geometry is not so important, so are used only selected parameters such as the length of the robot arm, the center of gravity, moment of inertia. These parameters are introduced into the equations of motion of the robot and motion parameters are determined.

  17. A New Cancer Radiotherapy System Using Multi Robotic Manipulators

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Lee, Nam Ho; Lee, Byung Chul; Jeung, Kyung Min; Lee, Seong Uk; Bae, Yeong Geol; Na, Hyun Seok

    2013-01-01

    The CyberKnife system is state-of-the-art cancer treatment equipment that combines an image tracking technique, artificial intelligence software, robot technology, accelerator technology, and treatment simulation technology. The current CyberKnife System has significant shortcomings. The biggest problem is that it takes a longer time to treat a tumor. A long treatment time gives stress to patients. Furthermore it makes the patients uncomfortable with radiation and thus it is difficult to measure the exact radiation dose rate to the tumor in the processing. Linear accelerators for radiation treatment are dependent on imports, and demand high maintenance cost. This also makes the treatment cost higher and prevents the popularization of radiation. To solve the disadvantages of the existing CyberKnife, a radiation treatment robot system applied to several articulated robots is suggested. Essential element techniques for new radiotherapy robot system are investigated and some problems of similar existing systems are analyzed. This paper presents a general configuration of a new radiation robot treatment system including with a quantitative goal of the requirement techniques. This paper described a new radiotherapy robot system to track the tumor using multiple articulated robots in real time. The existing CyberKnife system using a single robot arm has disadvantages of a long radiotherapy time, high medical fee, and inaccurate measurement of the radiotherapy dose. So a new radiotherapy robot system for tumors has been proposed to solve the above problems of conventional CyberKnife systems. Necessary technologies to configure new the radiotherapy robot system have been identified. Quantitative targets of each technology have been established. Multiple robot arms are adopted to decrease the radiotherapy time. The results of this research are provided as a requisite technology for a domestic radiotherapy system and are expected to be the foundation of new technology. The

  18. A New Cancer Radiotherapy System Using Multi Robotic Manipulators

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Lee, Nam Ho; Lee, Byung Chul; Jeung, Kyung Min; Lee, Seong Uk; Bae, Yeong Geol; Na, Hyun Seok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The CyberKnife system is state-of-the-art cancer treatment equipment that combines an image tracking technique, artificial intelligence software, robot technology, accelerator technology, and treatment simulation technology. The current CyberKnife System has significant shortcomings. The biggest problem is that it takes a longer time to treat a tumor. A long treatment time gives stress to patients. Furthermore it makes the patients uncomfortable with radiation and thus it is difficult to measure the exact radiation dose rate to the tumor in the processing. Linear accelerators for radiation treatment are dependent on imports, and demand high maintenance cost. This also makes the treatment cost higher and prevents the popularization of radiation. To solve the disadvantages of the existing CyberKnife, a radiation treatment robot system applied to several articulated robots is suggested. Essential element techniques for new radiotherapy robot system are investigated and some problems of similar existing systems are analyzed. This paper presents a general configuration of a new radiation robot treatment system including with a quantitative goal of the requirement techniques. This paper described a new radiotherapy robot system to track the tumor using multiple articulated robots in real time. The existing CyberKnife system using a single robot arm has disadvantages of a long radiotherapy time, high medical fee, and inaccurate measurement of the radiotherapy dose. So a new radiotherapy robot system for tumors has been proposed to solve the above problems of conventional CyberKnife systems. Necessary technologies to configure new the radiotherapy robot system have been identified. Quantitative targets of each technology have been established. Multiple robot arms are adopted to decrease the radiotherapy time. The results of this research are provided as a requisite technology for a domestic radiotherapy system and are expected to be the foundation of new technology. The

  19. Towards Sociable Robots

    DEFF Research Database (Denmark)

    Ngo, Trung Dung

    This thesis studies aspects of self-sufficient energy (energy autonomy) for truly autonomous robots and towards sociable robots. Over sixty years of history of robotics through three developmental ages containing single robot, multi-robot systems, and social (sociable) robots, the main objective...... of roboticists mostly focuses on how to make a robotic system function autonomously and further, socially. However, such approaches mostly emphasize behavioural autonomy, rather than energy autonomy which is the key factor for not only any living machine, but for life on the earth. Consequently, self......-sufficient energy is one of the challenges for not only single robot or multi-robot systems, but also social and sociable robots. This thesis is to deal with energy autonomy for multi-robot systems through energy sharing (trophallaxis) in which each robot is equipped with two capabilities: self-refueling energy...

  20. Biomass feeds vegetarian robot; Biomassa voedt vegetarische robot

    Energy Technology Data Exchange (ETDEWEB)

    Van den Brandt, M. [Office for Science and Technology, Embassy of the Kingdom of the Netherlands, Washington (United States)

    2009-09-15

    This brief article addresses the EATR robot (Energetically Autonomous Tactical Robot) that was developed by Cyclone Power and uses biomass as primary source of energy for propulsion. [Dutch] Een kort artikel over de door Cyclone Power ontwikkelde EATR-robot (Energetically Autonomous Tactical Robot) die voor de voortdrijving biomassa gebruikt als primaire energiebron.

  1. Robot Futures

    DEFF Research Database (Denmark)

    Christoffersen, Anja; Grindsted Nielsen, Sally; Jochum, Elizabeth Ann

    Robots are increasingly used in health care settings, e.g., as homecare assistants and personal companions. One challenge for personal robots in the home is acceptance. We describe an innovative approach to influencing the acceptance of care robots using theatrical performance. Live performance...... is a useful testbed for developing and evaluating what makes robots expressive; it is also a useful platform for designing robot behaviors and dialogue that result in believable characters. Therefore theatre is a valuable testbed for studying human-robot interaction (HRI). We investigate how audiences...... perceive social robots interacting with humans in a future care scenario through a scripted performance. We discuss our methods and initial findings, and outline future work....

  2. Soft Robotics Week

    CERN Document Server

    Rossiter, Jonathan; Iida, Fumiya; Cianchetti, Matteo; Margheri, Laura

    2017-01-01

    This book offers a comprehensive, timely snapshot of current research, technologies and applications of soft robotics. The different chapters, written by international experts across multiple fields of soft robotics, cover innovative systems and technologies for soft robot legged locomotion, soft robot manipulation, underwater soft robotics, biomimetic soft robotic platforms, plant-inspired soft robots, flying soft robots, soft robotics in surgery, as well as methods for their modeling and control. Based on the results of the second edition of the Soft Robotics Week, held on April 25 – 30, 2016, in Livorno, Italy, the book reports on the major research lines and novel technologies presented and discussed during the event.

  3. Towards Versatile Robots Through Open Heterogeneous Modular Robots

    OpenAIRE

    Lyder, Andreas

    2010-01-01

    Robots are important tools in our everyday life. Both in industry and at the consumer level they serve the purpose of increasing our scope and extending our capabilities. Modular robots take the next step, allowing us to easily create and build various robots from a set of modules. If a problem arises, a new robot can be assembled rapidly from the existing modules, in contrast to conventional robots, which require a time consuming and expensive development process. In this thesis we define a ...

  4. Robotic architectures

    CSIR Research Space (South Africa)

    Mtshali, M

    2010-01-01

    Full Text Available In the development of mobile robotic systems, a robotic architecture plays a crucial role in interconnecting all the sub-systems and controlling the system. The design of robotic architectures for mobile autonomous robots is a challenging...

  5. Review of surgical robotics user interface: what is the best way to control robotic surgery?

    Science.gov (United States)

    Simorov, Anton; Otte, R Stephen; Kopietz, Courtni M; Oleynikov, Dmitry

    2012-08-01

    As surgical robots begin to occupy a larger place in operating rooms around the world, continued innovation is necessary to improve our outcomes. A comprehensive review of current surgical robotic user interfaces was performed to describe the modern surgical platforms, identify the benefits, and address the issues of feedback and limitations of visualization. Most robots currently used in surgery employ a master/slave relationship, with the surgeon seated at a work-console, manipulating the master system and visualizing the operation on a video screen. Although enormous strides have been made to advance current technology to the point of clinical use, limitations still exist. A lack of haptic feedback to the surgeon and the inability of the surgeon to be stationed at the operating table are the most notable examples. The future of robotic surgery sees a marked increase in the visualization technologies used in the operating room, as well as in the robots' abilities to convey haptic feedback to the surgeon. This will allow unparalleled sensation for the surgeon and almost eliminate inadvertent tissue contact and injury. A novel design for a user interface will allow the surgeon to have access to the patient bedside, remaining sterile throughout the procedure, employ a head-mounted three-dimensional visualization system, and allow the most intuitive master manipulation of the slave robot to date.

  6. CA-125–indicated asymptomatic relapse confers survival benefit to ovarian cancer patients who underwent secondary cytoreduction surgery

    Directory of Open Access Journals (Sweden)

    Wang Fang

    2013-02-01

    Full Text Available Abstract Background There is no consensus regarding the management of ovarian cancer patients, who have shown complete clinical response (CCR to primary therapy and have rising cancer antigen CA-125 levels but have no symptoms of recurrent disease. The present study aims to determine whether follow-up CA-125 levels can be used to identify the need for imaging studies and secondary cytoreductive surgery (CRS. Methods We identified 410 ovarian cancer patients treated at The University of Texas MD Anderson Cancer Center between 1984 and 2011. These patients had shown CCR to primary therapy. Follow-up was conducted based on the surveillance protocol of the MD Anderson Cancer Center. We used the Cox proportional hazards model and log-rank test to assess the associations between the follow-up CA-125 levels and secondary CRS and survival duration. Results The CA-125 level of 1.68 × nadir was defined as the indicator of recurrent disease (p  1.68 × nadir at relapse (55.7 and 10.4 months; p = 0.04 and 0.01, respectively. The overall and progression free survival duration of patients with asymptomatic relapse and underwent a secondary CRS was longer than that of patients with symptomatic relapse (p = 0.02 and 0.04 respectively. Conclusions The increase of serum CA-125 levels is an early warning of clinical relapse in ovarian cancer. Using CA-125 levels in guiding the treatment of patients with asymptomatic recurrent ovarian cancer, who have shown CCR to primary therapy, can facilitate optimal secondary CRS and extend the survival duration of the patients.

  7. Computational Architecture of a Robot Coach for Physical Exercises in Kinesthetic Rehabilitation

    OpenAIRE

    Nguyen , Sao Mai; Tanguy , Philippe; Rémy-Néris , Olivier

    2016-01-01

    International audience; The rising number of the elderly incurs growing concern about healthcare, and in particular rehabilitation healthcare. Assistive technology and and assistive robotics in particular may help to improve this process. We develop a robot coach capable of demonstrating rehabilitation exercises to patients, watch a patient carry out the exercises and give him feedback so as to improve his performance and encourage him. We propose a general software architecture for our robot...

  8. Soft Robotics.

    Science.gov (United States)

    Whitesides, George M

    2018-04-09

    This description of "soft robotics" is not intended to be a conventional review, in the sense of a comprehensive technical summary of a developing field. Rather, its objective is to describe soft robotics as a new field-one that offers opportunities to chemists and materials scientists who like to make "things" and to work with macroscopic objects that move and exert force. It will give one (personal) view of what soft actuators and robots are, and how this class of soft devices fits into the more highly developed field of conventional "hard" robotics. It will also suggest how and why soft robotics is more than simply a minor technical "tweak" on hard robotics and propose a unique role for chemistry, and materials science, in this field. Soft robotics is, at its core, intellectually and technologically different from hard robotics, both because it has different objectives and uses and because it relies on the properties of materials to assume many of the roles played by sensors, actuators, and controllers in hard robotics. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Clinical applications of robotic technology in vascular and endovascular surgery.

    Science.gov (United States)

    Antoniou, George A; Riga, Celia V; Mayer, Erik K; Cheshire, Nicholas J W; Bicknell, Colin D

    2011-02-01

    Emerging robotic technologies are increasingly being used by surgical disciplines to facilitate and improve performance of minimally invasive surgery. Robot-assisted intervention has recently been introduced into the field of vascular surgery to potentially enhance laparoscopic vascular and endovascular capabilities. The objective of this study was to review the current status of clinical robotic applications in vascular surgery. A systematic literature search was performed in order to identify all published clinical studies related to robotic implementation in vascular intervention. Web-based search engines were searched using the keywords "surgical robotics," "robotic surgery," "robotics," "computer assisted surgery," and "vascular surgery" or "endovascular" for articles published between January 1990 and November 2009. An evaluation and critical overview of these studies is reported. In addition, an analysis and discussion of supporting evidence for robotic computer-enhanced telemanipulation systems in relation to their applications in laparoscopic vascular and endovascular surgery was undertaken. Seventeen articles reporting on clinical applications of robotics in laparoscopic vascular and endovascular surgery were detected. They were either case reports or retrospective patient series and prospective studies reporting laparoscopic vascular and endovascular treatments for patients using robotic technology. Minimal comparative clinical evidence to evaluate the advantages of robot-assisted vascular procedures was identified. Robot-assisted laparoscopic aortic procedures have been reported by several studies with satisfactory results. Furthermore, the use of robotic technology as a sole modality for abdominal aortic aneurysm repair and expansion of its applications to splenic and renal artery aneurysm reconstruction have been described. Robotically steerable endovascular catheter systems have potential advantages over conventional catheterization systems

  10. Robotic Whipple Procedure for Pancreatic Cancer: The Moffitt Cancer Center Pathway.

    Science.gov (United States)

    Rashid, Omar M; Mullinax, John E; Pimiento, Jose M; Meredith, Kenneth L; Malafa, Mokenge P

    2015-07-01

    Resection of malignancies in the head and uncinate process of the pancreas (Whipple procedure) using a robotic approach is emerging as a surgical option. Although several case series of the robotic Whipple procedure have been reported, detailed descriptions of operative techniques and a clear pathway for adopting this technology are lacking. We present a focused review of the procedure as it applies to pancreatic cancer and describe our clinical pathway for the robotic Whipple procedure used in pancreatic cancer and review the outcomes of our early experience. A systematic review of the literature is provided, focusing on the indications, variations in surgical techniques, complications, and oncological results of the robotic Whipple procedure. A clinical pathway has been defined for preoperative training of surgeons, the requirements for hospital privileges, patient selection, and surgical techniques for the robotic Whipple procedure. The robotic technique for managing malignant lesions of the pancreas head is safe when following well-established guidelines for adopting the technology. Preliminary data demonstrate that perioperative convalescence may exceed end points when compared with the open technique. The robotic Whipple procedure is a minimally invasive approach for select patients as part of multidisciplinary management of periampullary lesions in tertiary centers where clinicians have developed robotic surgical programs. Prospective trials are needed to define the short- and long-term benefits of the robotic Whipple procedure.

  11. Two-port robotic hysterectomy: a novel approach.

    Science.gov (United States)

    Moawad, Gaby N; Tyan, Paul; Khalil, Elias D Abi

    2018-03-24

    The objective of the study was to demonstrate a novel technique for two-port robotic hysterectomy with a particular focus on the challenging portions of the procedure. The study is designed as a technical video, showing step-by-step a two-port robotic hysterectomy approach (Canadian Task Force classification level III). IRB approval was not required for this study. The benefits of minimally invasive surgery for gynecological pathology have been clearly documented in multiple studies. Patients had fewer medical and surgical complications postoperatively, better cosmesis and quality of life. Most gynecological surgeons require 3-5 ports for the standard gynecological procedure. Even though the minimally invasive multiport system provides an excellent safety profile, multiple incisions are associated with a greater risk for morbidity including infection, pain, and hernia. In the past decade, various new methods have emerged to minimize the number of ports used in gynecological surgery. The interventions employed were a two-port robotic hysterectomy, using a camera port plus one robotic arm, with a focus on salpingectomy and cuff closure. We describe a transvaginal and a transabdominal approach for salpingectomy and a novel method for cuff closure. The transvaginal and transabdominal techniques for salpingectomy for two-port robotic-assisted hysterectomy provide excellent tension and exposure for a safe procedure without the need for an extra port. We also describe a transvaginal technique to place the vaginal cuff on tension during closure. With the necessary set of skills on a carefully chosen patient, two-port robotic-assisted total laparoscopic hysterectomy is a feasible procedure.

  12. First year experience of robotic-assisted laparoscopic surgery with 153 cases in a general surgery department: indications, technique and results.

    Science.gov (United States)

    Tomulescu, V; Stănciulea, O; Bălescu, I; Vasile, S; Tudor, St; Gheorghe, C; Vasilescu, C; Popescu, I

    2009-01-01

    Robotic surgery was developed in response to the limitations and drawbacks of laparoscopic surgery. Since 1997 when the first robotic procedure was performed various papers pointed the advantages of robotic-assisted laparoscopic surgery, this technique is now a reality and it will probably become the surgery of the future. The aim of this paper is to present our preliminary experience with the three-arms "da Vinci S surgical system", to assess the feasibility of this technique in various abdominal and thoracic procedures and to point out the advantages of the robotic approach for each type of procedure. Between 18 January 2008 and 18 January 2009 153 patients (66 men and 87 women; mean age 48,02 years, range 6 to 84 years) underwent robotic-assisted surgical procedures in our institution; we performed 129 abdominal and 24 thoracic procedures, as follows: one cholecystectomy, 14 myotomies with Dor fundoplication, one gastroenteroanastomosis for unresectable antral gastric cancer, one transthoracic esophagectomy, 14 gastrectomies, one polypectomy through gastrotomy, 22 splenectomies,7 partial spleen resections, 22 thymectomy, 6 Nissen fundoplications, one Toupet fundoplication, one choledocho-duodeno-anastomosis, one drainage for pancreatic abscess, one distal pancreatectomy, one hepatic cyst fenestration, 7 hepatic resections, 29 colonic and rectal resections, 5 adrenalectomies, 12 total radical hysterectomies and pelvic lymphadenectomy, 3 hysterectomies with bilateral adnexectomy for uterine fibroma, one unilateral adnexectomy, and 2 cases of cervico-mediastinal goitre resection. 147 procedures were robotics completed , whereas 6 procedures were converted to open surgery due to the extent of the lesion. Average operating room time was 171 minutes (range 60 to 600 minutes, Median length of stay was 8,6 days (range 2 to 48 days). One system malfunctions was registered. Post-operatory complications occurred in 14 cases. There were no deaths. Our preliminary experience

  13. The impact of robotic surgery in urology.

    Science.gov (United States)

    Giedelman, C A; Abdul-Muhsin, H; Schatloff, O; Palmer, K; Lee, L; Sanchez-Salas, R; Cathelineau, X; Dávila, H; Cavelier, L; Rueda, M; Patel, V

    2013-01-01

    More than a decade ago, robotic surgery was introduced into urology. Since then, the urological community started to look at surgery from a different angle. The present, the future hopes, and the way we looked at our past experience have all changed. Between 2000 and 2011, the published literature was reviewed using the National Library of Medicine database and the following key words: robotic surgery, robot-assisted, and radical prostatectomy. Special emphasis was given to the impact of the robotic surgery in urology. We analyzed the most representative series (finished learning curve) in each one of the robotic approaches regarding perioperative morbidity and oncological outcomes. This article looks into the impact of robotics in urology, starting from its background applications before urology, the way it was introduced into urology, its first steps, current status, and future expectations. By narrating this journey, we tried to highlight important modifications that helped robotic surgery make its way to its position today. We looked as well into the dramatic changes that robotic surgery introduced to the field of surgical training and its consequence on its learning curve. Basic surgical principles still apply in Robotics: experience counts, and prolonged practice provides knowledge and skills. In this way, the potential advantages delivered by technology will be better exploited, and this will be reflected in better outcomes for patients. Copyright © 2012 AEU. Published by Elsevier Espana. All rights reserved.

  14. Exploiting Child-Robot Aesthetic Interaction for a Social Robot

    OpenAIRE

    Lee, Jae-Joon; Kim, Dae-Won; Kang, Bo-Yeong

    2012-01-01

    A social robot interacts and communicates with humans by using the embodied knowledge gained from interactions with its social environment. In recent years, emotion has emerged as a popular concept for designing social robots. Several studies on social robots reported an increase in robot sociability through emotional imitative interactions between the robot and humans. In this paper conventional emotional interactions are extended by exploiting the aesthetic theories that the sociability of ...

  15. Critical analysis of the literature investigating urogenital function preservation following robotic rectal cancer surgery

    Institute of Scientific and Technical Information of China (English)

    Sofoklis; Panteleimonitis; Jamil; Ahmed; Mick; Harper; Amjad; Parvaiz

    2016-01-01

    AIM To analyses the current literature regarding the urogenital functional outcomes of patients receiving robotic rectal cancer surgery. METHODS A comprehensive literature search of electronic databases was performed in October 2015. The following search terms were applied: 'rectal cancer' or 'colorectal cancer' and robot* or 'da Vinci' and sexual or urolog* or urinary or erect* or ejaculat* or impot* or incontinence. All original studies examining the urological and/or sexual outcomes of male and/or female patients receiving robotic rectal cancer surgery were included. Reference lists of all retrieved articles were manually searched for further relevant articles. Abstracts were independently searched by two authors. RESULTS Fifteen original studies fulfilled the inclusion criteria. A total of 1338 patients were included; 818 received robotic, 498 laparoscopic and 22 open rectal cancer surgery. Only 726(54%) patients had their urogenital function assessed via means of validated functional questionnaires. From the included studies, three found that robotic rectal cancer surgery leads to quicker recovery of male urological function and five of male sexual function as compared to laparoscopic surgery. It is unclear whether robotic surgery offers favourable urogenital outcomes in the long run for males. In female patients only two studies assessed urological and threesexual function independently to that of males. In these studies there was no difference identified between patients receiving robotic and laparoscopic rectal cancer surgery. However, in females the presented evidence was very limited making it impossible to draw any substantial conclusions. CONCLUSION There seems to be a trend towards earlier recovery of male urogenital function following robotic surgery. To evaluate this further, larger well designed studies are required.

  16. Critical analysis of the literature investigating urogenital function preservation following robotic rectal cancer surgery

    Institute of Scientific and Technical Information of China (English)

    Sofoklis; Panteleimonitis[1,2; Jamil; Ahmed[1; Mick; Harper[2; Amjad; Parvaiz[1,2

    2016-01-01

    AIM To analyses the current literature regarding the urogenital functional outcomes of patients receiving robotic rectal cancer surgery.METHODS A comprehensive literature search of electronic databases was performed in October 2015. The following search terms were applied: “rectal cancer” or “colorectal cancer” and robot* or “da Vinci” and sexual or urolog* or urinary or erect* or ejaculat* or impot* or incontinence.All original studies examining the urological and/or sexual outcomes of male and/or female patients receiving robotic rectal cancer surgery were included. Reference lists of all retrieved articles were manually searched for further relevant articles. Abstracts were independently searched by two authors.RESULTS Fifteen original studies fulfilled the inclusion criteria.A total of 1338 patients were included; 818 received robotic, 498 laparoscopic and 22 open rectal cancer surgery. Only 726 (54%) patients had their urogenital function assessed via means of validated functional questionnaires. From the included studies, three found that robotic rectal cancer surgery leads to quicker recovery of male urological function and five of male sexual function as compared to laparoscopic surgery.It is unclear whether robotic surgery offers favourable urogenital outcomes in the long run for males. In female patients only two studies assessed urological and three sexual function independently to that of males. In these studies there was no difference identified between patients receiving robotic and laparoscopic rectal cancer surgery. However, in females the presented evidence was very limited making it impossible to draw any substantial conclusions.CONCLUSION There seems to be a trend towards earlier recovery of male urogenital function following robotic surgery. To evaluate this further, larger well designed studies are required.

  17. A preliminary oncologic outcome and postoperative complications in patients undergoing robot-assisted radical cystectomy: Initial experience

    Directory of Open Access Journals (Sweden)

    Satoru Muto

    2017-05-01

    Full Text Available Purpose: Robot-assisted radical cystectomy (RARC was originally intended to replace open radical cystectomy (ORC as a minimally invasive surgery for patients with invasive bladder cancer. The purpose of this study was to evaluate the advantages of robotic surgery, comparing perioperative and oncologic outcomes between RARC and ORC. Materials and Methods: Between June 2012 and August 2016, 49 bladder cancer patients were given a radical cystectomy, 21 robotically and 28 by open procedure. We compared the clinical variables between the RARC and ORC groups. Results: In the RARC group, the median estimated blood loss (EBL during cystectomy, total EBL, operative time during cystectomy, and total operative time were 0 mL, 457.5 mL, 199 minutes, and 561 minutes, respectively. EBL during cystectomy (p<0.001, total EBL (p<0.001, and operative time during cystectomy (p=0.003 in the RARC group were significantly lower compared with the ORC group. Time to resumption of a regular diet (p<0.001 and length of stay (p=0.017 were also significantly shorter compared with the ORC group. However, total operative time in the RARC group (median, 561 minutes was significantly longer compared with the ORC group (median, 492.5 minutes; p=0.015. Conclusions: This Japanese study presented evidence that RARC yields benefits in terms of BL and time to regular diet, while consuming greater total operative time. RARC may be a minimally invasive surgical alternative to ORC with less EBL and shorter length of stay.

  18. Evolutionary robotics

    Indian Academy of Sciences (India)

    In evolutionary robotics, a suitable robot control system is developed automatically through evolution due to the interactions between the robot and its environment. It is a complicated task, as the robot and the environment constitute a highly dynamical system. Several methods have been tried by various investigators to ...

  19. Robotic and Sensor Technologies for Mobility in Older People.

    Science.gov (United States)

    Penteridis, Lazaros; D'Onofrio, Grazia; Sancarlo, Daniele; Giuliani, Francesco; Ricciardi, Francesco; Cavallo, Filippo; Greco, Antonio; Trochidis, Ilias; Gkiokas, Alexander

    2017-10-01

    Maintaining independent mobility is fundamental to independent living and to the quality of life of older people. Robotic and sensor technologies may offer a lot of potential and can make a significant difference in the lives of older people and to their primary caregivers. The aim of this study was to provide a presentation of the methods that are used up till now for analysis and evaluation of human mobility utilizing sensor technologies and to give the state of the art in robotic platforms for supporting older people with mobility limitations. The literature was reviewed and systematic reviews of cohort studies and other authoritative reports were identified. The selection criteria included (1) patients with age ≥60 years; (2) patients with unstable gait, with or without recurrent falls; (3) patients with slow movements, short strides, and little trunk movement; (4) sensor technologies that are currently used for mobility evaluation; and (5) robotic technologies that can serve as a supporting companion for older people with mobility limitations. One hundred eighty-one studies published up until February 2017 were identified, of which 36 were included. Two categories of research were identified from the review regarding the robot and sensor technologies: (1) sensor technologies for mobility analysis and (2) robots for supporting older people with mobility limitations. Potential for robotic and sensor technologies can be taken advantage of for evaluation and support at home for elder persons with mobility limitations in an automated way without the need of the physical presence of any medical personnel, reducing the stress of caregivers.

  20. Robotic mitral valve operations by experienced surgeons are cost-neutral and durable at 1 year.

    Science.gov (United States)

    Coyan, Garrett; Wei, Lawrence M; Althouse, Andrew; Roberts, Harold G; Schauble, Drew; Murashita, Takashi; Cook, Chris C; Rankin, J Scott; Badhwar, Vinay

    2018-04-12

    Robotic mitral valve surgery has potential advantages in patient satisfaction and 30-day outcome. Cost concerns and repair durability limit wider adoption of robotic technology. This study examined detailed cost differences between robotic and sternotomy techniques in relation to outcomes and durability following robotic mitral program initiation. Between April 2013 and October 2015, 30-day and 1-year outcomes of 328 consecutive patients undergoing robotic or sternotomy mitral valve repair or replacement by experienced surgeons were examined. Multivariable logistic regression informed propensity matching to derive a cohort of 182 patients. Echocardiographic follow-up was completed at 1 year in all robotic patients. Detailed activity-based cost accounting was applied to include direct, semidirect, and indirect costs with special respect to robotic depreciation, maintenance, and supplies. A quantitative analysis of all hospital costs was applied directly to each patient encounter for comparative financial analyses. Mean predicted risk of mortality was similar in both the robotic (n = 91) and sternotomy (n = 91) groups (0.9% vs 0.8%; P > .431). The total costs of robotic mitral operations were similar to those of sternotomy ($27,662 vs $28,241; P = .273). Early direct costs were higher in the robotic group. There was a marked increase in late indirect cost with the sternotomy cohort related to increased length of stay, transfusion requirements, and readmission rates. Robotic repair technique was associated with no echocardiographic recurrence greater than trace to only mild regurgitation at 1 year. Experienced mitral surgeons can initiate a robotic program in a cost-neutral manner that maintains clinical outcome integrity as well as repair durability. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  1. Predicting Functional Recovery in Chronic Stroke Rehabilitation Using Event-Related Desynchronization-Synchronization during Robot-Assisted Movement

    Science.gov (United States)

    Gramigna, Cristina; Franceschetti, Silvana

    2016-01-01

    Although rehabilitation robotics seems to be a promising therapy in the rehabilitation of the upper limb in stroke patients, consensus is still lacking on its additive effects. Therefore, there is a need for determining the possible success of robotic interventions on selected patients, which in turn determine the necessity for new investigating instruments supporting the treatment decision-making process and customization. The objective of the work presented in this preliminary study was to verify that fully robot assistance would not affect the physiological oscillatory cortical activity related to a functional movement in healthy subjects. Further, the clinical results following the robotic treatment of a chronic stroke patient, who positively reacted to the robotic intervention, were analyzed and discussed. First results show that there is no difference in EEG activation pattern between assisted and no-assisted movement in healthy subjects. Even more importantly, the patient's pretreatment EEG activation pattern in no-assisted movement was completely altered, while it recovered to a quasi-physiological one in robot-assisted movement. The functional improvement following treatment was large. Using pretreatment EEG recording during robot-assisted movement might be a valid approach to assess the potential ability of the patient for recovering. PMID:27057546

  2. Interactive Exploration Robots: Human-Robotic Collaboration and Interactions

    Science.gov (United States)

    Fong, Terry

    2017-01-01

    For decades, NASA has employed different operational approaches for human and robotic missions. Human spaceflight missions to the Moon and in low Earth orbit have relied upon near-continuous communication with minimal time delays. During these missions, astronauts and mission control communicate interactively to perform tasks and resolve problems in real-time. In contrast, deep-space robotic missions are designed for operations in the presence of significant communication delay - from tens of minutes to hours. Consequently, robotic missions typically employ meticulously scripted and validated command sequences that are intermittently uplinked to the robot for independent execution over long periods. Over the next few years, however, we will see increasing use of robots that blend these two operational approaches. These interactive exploration robots will be remotely operated by humans on Earth or from a spacecraft. These robots will be used to support astronauts on the International Space Station (ISS), to conduct new missions to the Moon, and potentially to enable remote exploration of planetary surfaces in real-time. In this talk, I will discuss the technical challenges associated with building and operating robots in this manner, along with lessons learned from research conducted with the ISS and in the field.

  3. Brain-state dependent robotic reaching movement with a multi-joint arm exoskeleton: combining brain-machine interfacing and robotic rehabilitation

    Directory of Open Access Journals (Sweden)

    Daniel eBrauchle

    2015-10-01

    Full Text Available While robot-assisted arm and hand training after stroke allows for intensive task-oriented practice, it has provided only limited additional benefit over dose-matched physiotherapy up to now. These rehabilitation devices are possibly too supportive during the exercises. Neurophysiological signals might be one way of avoiding slacking and providing robotic support only when the brain is particularly responsive to peripheral input.We tested the feasibility of three-dimensional robotic assistance for reach-to-grasp movements with a multi-joint exoskeleton during motor imagery-related desynchronization of sensorimotor oscillations in the β-band only. We also registered task-related network changes of cortical functional connectivity by electroencephalography via the imaginary part of the coherence function.Healthy subjects and stroke survivors showed similar patterns – but different aptitudes – of controlling the robotic movement. All participants in this pilot study with nine healthy subjects and two stroke patients achieved their maximum performance during the early stages of the task. Robotic control was significantly higher and less variable when proprioceptive feedback was provided in addition to visual feedback, i.e. when the orthosis was actually attached to the subject’s arm during the task. A distributed cortical network of task-related coherent activity in the θ-band showed significant differences between healthy subjects and stroke patients as well as between early and late periods of the task.Brain-robot interfaces may successfully link three-dimensional robotic training to the participants’ efforts and allow for task-oriented practice of activities of daily living with a physiologically controlled multi-joint exoskeleton. Changes of cortical physiology during the task might also help to make subject-specific adjustments of task difficulty and guide adjunct interventions to facilitate motor learning for functional restoration.

  4. A Fully Sensorized Cooperative Robotic System for Surgical Interventions

    Science.gov (United States)

    Tovar-Arriaga, Saúl; Vargas, José Emilio; Ramos, Juan M.; Aceves, Marco A.; Gorrostieta, Efren; Kalender, Willi A.

    2012-01-01

    In this research a fully sensorized cooperative robot system for manipulation of needles is presented. The setup consists of a DLR/KUKA Light Weight Robot III especially designed for safe human/robot interaction, a FD-CT robot-driven angiographic C-arm system, and a navigation camera. Also, new control strategies for robot manipulation in the clinical environment are introduced. A method for fast calibration of the involved components and the preliminary accuracy tests of the whole possible errors chain are presented. Calibration of the robot with the navigation system has a residual error of 0.81 mm (rms) with a standard deviation of ±0.41 mm. The accuracy of the robotic system while targeting fixed points at different positions within the workspace is of 1.2 mm (rms) with a standard deviation of ±0.4 mm. After calibration, and due to close loop control, the absolute positioning accuracy was reduced to the navigation camera accuracy which is of 0.35 mm (rms). The implemented control allows the robot to compensate for small patient movements. PMID:23012551

  5. Retention of laparoscopic and robotic skills among medical students: a randomized controlled trial.

    Science.gov (United States)

    Orlando, Megan S; Thomaier, Lauren; Abernethy, Melinda G; Chen, Chi Chiung Grace

    2017-08-01

    Although simulation training beneficially contributes to traditional surgical training, there are less objective data on simulation skills retention. To investigate the retention of laparoscopic and robotic skills after simulation training. We present the second stage of a randomized single-blinded controlled trial in which 40 simulation-naïve medical students were randomly assigned to practice peg transfer tasks on either laparoscopic (N = 20, Fundamentals of Laparoscopic Surgery, Venture Technologies Inc., Waltham, MA) or robotic (N = 20, dV-Trainer, Mimic, Seattle, WA) platforms. In the first stage, two expert surgeons evaluated participants on both tasks before (Stage 1: Baseline) and immediately after training (Stage 1: Post-training) using a modified validated global rating scale of laparoscopic and robotic operative performance. In Stage 2, participants were evaluated on both tasks 11-20 weeks after training. Of the 40 students who participated in Stage 1, 23 (11 laparoscopic and 12 robotic) underwent repeat evaluation. During Stage 2, there were no significant differences between groups in objective or subjective measures for the laparoscopic task. Laparoscopic-trained participants' performances on the laparoscopic task were improved during Stage 2 compared to baseline measured by time to task completion, but not by the modified global rating scale. During the robotic task, the robotic-trained group demonstrated superior economy of motion (p = .017), Tissue Handling (p = .020), and fewer errors (p = .018) compared to the laparoscopic-trained group. Robotic skills acquisition from baseline with no significant deterioration as measured by modified global rating scale scores was observed among robotic-trained participants during Stage 2. Robotic skills acquired through simulation appear to be better maintained than laparoscopic simulation skills. This study is registered on ClinicalTrials.gov (NCT02370407).

  6. Incorporating robotic-assisted surgery for endometrial cancer staging: Analysis of morbidity and costs.

    Science.gov (United States)

    Bogani, Giorgio; Multinu, Francesco; Dowdy, Sean C; Cliby, William A; Wilson, Timothy O; Gostout, Bobbie S; Weaver, Amy L; Borah, Bijan J; Killian, Jill M; Bijlani, Akash; Angioni, Stefano; Mariani, Andrea

    2016-05-01

    To evaluate how the introduction of robotic-assisted surgery affects treatment-related morbidity and cost of endometrial cancer (EC) staging. We retrospectively reviewed the records of consecutive patients with stage I-III EC undergoing surgical staging between 2007 and 2012 at our institution. Costs (from surgery to 30days after surgery) were set based on the Medicare cost-to-charge ratio for each year and inflated to 2014 values. Inverse probability weighting (IPW) was used to decrease the allocation bias when comparing outcomes between surgical groups. We focused our analysis on the 251 EC patients who had robotic-assisted surgery and the 384 who had open staging. During the study period, the use of robotic-assisted surgery increased and open staging decreased (P<0.001). Correcting group imbalances by using IPW methodology, we observed that patients undergoing robotic-assisted staging had a significantly lower postoperative complication rate, lower blood transfusion rate, longer median operating time, shorter median length of stay, and lower readmission rate than patients undergoing open staging (all P<0.001). Overall 30-day costs were similar between the 2 groups, with robotic-assisted surgery having significantly higher median operating room costs ($2820 difference; P<0.001) but lower median room and board costs ($2929 difference; P<0.001) than open surgery. Increasing experience with robotic-assisted staging was significantly associated with a decrease in median operating time (P=0.002) and length of stay (P=0.003). The implementation of robotic-assisted surgery for EC staging improves patient outcomes. It provides women the benefits of minimally invasive surgery without increasing costs and potentially improves patient turnover. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. The Characteristics of Cervical Cancer Patients Who Underwent a Radical Hysterectomy at Sanglah Hospital Denpasar in 2015

    Directory of Open Access Journals (Sweden)

    I Nyoman Bayu Mahendra

    2016-05-01

    Full Text Available Background: Cervical cancer is the most common gynecologic cancer in women. It is the main cause of cancer-related death in women in developing countries. Cervical cancer in Indonesia is the second most cancer affecting Indonesian women and the prevalence is relatively stable in the last 30 years. Cervical cancer was closely related to the histologic type of itself. A squamous cell carcinoma has a specific route of local spreading and a lymphatic route. The sample of this study are cervical cancer patients who underwent a radical hysterectomy from January 1 to December 31, 2015 in Sanglah Hospital Denpasar, Bali. The aim of this study is to discover the characteristics of the patients by age, parity, education level, marital status, sexual activity, the first symptoms and the early screening done, and the clinical staging. Methods: This descriptive study involved 20 patients in Sanglah Hospital Denpasar who had a radical hysterectomy from January 1 until December 31, 2015. The characteristics are gathered from the patients’ medical record. Results: The most cases done radical hysterectomy between 41-45 years old which proportion was 40%, the most parity was parity 2 (60%, elementary school was the most education level (35%, all of the samples only married once and sexually active, the most first symptom was vaginal bleeding (55%, only 10% had pap smear as early detection, and the most clinical stage was stage IIB (50%.

  8. A systematic review of methods for quantifying serum testosterone in patients with prostate cancer who underwent castration.

    Science.gov (United States)

    Comas, I; Ferrer, R; Planas, J; Celma, A; Regis, L; Morote, J

    2018-03-01

    The clinical practice guidelines recommend measuring serum testosterone in patients with prostate cancer (PC) who undergo castration. The serum testosterone concentration should be IA) has become widespread, although their metrological characteristics do not seem appropriate for quantifying low testosterone concentrations. The objective of this review is to analyse the methods for quantifying testosterone and to establish whether there is scientific evidence that justifies measuring it in patients with PC who undergo castration, through liquid chromatography attached to a mass spectrometry in tandem (LC-MSMS). We performed a search in PubMed with the following MeSH terms: measurement, testosterone, androgen suppression and prostate cancer. We selected 12 studies that compared the metrological characteristics of various methods for quantifying serum testosterone compared with MS detection methods. IAs are standard tools for measuring testosterone levels; however, there is evidence that IAs lack accuracy and precision for quantifying low concentrations. Most chemiluminescent IAs overestimate their concentration, especially below 100ng/dL. The procedures that use LC-MSMS have an adequate lower quantification limit and proper accuracy and precision. We found no specific evidence in patients with PC who underwent castration. LC-MSMS is the appropriate method for quantifying low serum testosterone concentrations. We need to define the level of castration with this method and the optimal level related to better progression of the disease. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Comparison of posterior retroperitoneal and transabdominal lateral approaches in robotic adrenalectomy: an analysis of 200 cases.

    Science.gov (United States)

    Kahramangil, Bora; Berber, Eren

    2018-04-01

    Although numerous studies have been published on robotic adrenalectomy (RA) in the literature, none has done a comparison of posterior retroperitoneal (PR) and transabdominal lateral (TL) approaches. The aim of this study was to compare the outcomes of robotic PR and TL adrenalectomy. This is a retrospective analysis of a prospectively maintained database. Between September 2008 and January 2017, perioperative outcomes of patients undergoing RA through PR and TL approaches were recorded into an IRB-approved database. Clinical and perioperative parameters were compared using Student's t test, Wilcoxon rank-sum test, and χ 2 test. Multivariate regression analysis was performed to determine factors associated with total operative time. 188 patients underwent 200 RAs. 110 patients were operated through TL and 78 patients through PR approach. Overall, conversion rate to open was 2.5% and 90-day morbidity 4.8%. The perioperative outcomes of TL and PR approaches were similar regarding estimated blood loss, rate of conversion to open, length of hospital stay, and 90-day morbidity. PR approach resulted in a shorter mean ± SD total operative time (136.3 ± 38.7 vs. 154.6 ± 48.4 min; p = 0.005) and lower visual analog scale pain score on postoperative day #1 (4.3 ± 2.5 vs. 5.4 ± 2.4; p = 0.001). After excluding tumors larger than 6 cm operated through TL approach, the difference in operative times persisted (136.3 ± 38.7 vs. 153.7 ± 45.7 min; p = 0.009). On multivariate regression analysis, increasing BMI and TL approaches were associated with longer total operative time. This study shows that robotic PR and TL approaches are equally safe and efficacious. With experience, shorter operative time and less postoperative pain can be achieved with PR technique. This supports the preferential utilization of PR approach in high-volume centers with enough experience.

  10. Laparoscopic, robotic and open method of radical hysterectomy for cervical cancer: A systematic review

    Directory of Open Access Journals (Sweden)

    Puliyath Geetha

    2012-01-01

    Full Text Available Background : Over the last two decades, numerous studies have indicated the feasibility of minimally invasive surgery for early cervical cancer without compromising the oncological outcome. Objective : Systematic literature review and meta analysis aimed at evaluating the outcome of laparoscopic and robotic radical hysterectomy (LRH and RRH and comparing the results with abdominal radical hysterectomy (ARH. Search Strategy : Medline, PubMed, Embase, Cochrane library and Reference lists were searched for articles published until January 31 st 2011, using the terms radical hysterectomy, laparoscopic radical hysterectomy, robotic radical hysterectomy, surgical treatment of cervical cancer and complications of radical hysterectomy. Selection Criteria : Studies that reported outcome measures of radical hysterectomy by open method, laparoscopic and robotic methods were selected. Data collection and analysis: Two independent reviewers selected studies, abstracted and tabulated the data and pooled estimates were obtained on the surgical and oncological outcomes. Results : Mean sample size, age and body mass index across the three types of RH studies were similar. Mean operation time across the three types of RH studies was comparable. Mean blood loss and transfusion rate are significantly higher in ARH compared to both LRH and RRH. Duration of stay in hospital for RRH was significantly less than the other two methods. The mean number of lymph nodes obtained, nodal metastasis and positive margins across the three types of RH studies were similar. Post operative infectious morbidity was significantly higher among patients who underwent ARH compared to the other two methods and a higher rate of cystotomy in LRH. Conclusions : Minimally invasive surgery especially robotic radical hysterectomy may be a better and safe option for surgical treatment of cervical cancer. The laparoscopic method is not free from complications. However, experience of surgeon may

  11. Tele-care robot for assisting independent senior citizens who live at home.

    Science.gov (United States)

    Katz, Reuven

    2015-01-01

    In the last twenty years most developed countries face dramatic demographic changes, and predominantly the rapid aging of their population. As the share of elderly people is climbing while the number of care providers is declining, the aging problem is becoming an increasingly important social and economic challenge. The supply of care at home, utilizing affordable tele-care systems and smart home technologies, is one of the promising strategies to cope with challenges posed by these demographic changes. The goal of this paper is to present a tele-care robot (TCR) aimed to assist Senior citizens who live independently at their home, that need assistance in daily life activities. The idea of the proposed system is that a caregiver, operating from a central location, will be able to service between 10 to 20 patients living at their home, by using the tele-care robot. The robot will possess motion control capabilities to move inside the house of each patient and alert in case that emergency events occur. The robot will allow the care provider to communicate remotely with the patient using audio and video equipment installed on the robot. By using the robot, the caregiver will be able to examine several times during the day the well-being of the patient, his medication consumption, and his overall functionality.

  12. Quality of life in locally advanced prostate cancer patients who underwent hormonal treatment combined with radiotherapy

    International Nuclear Information System (INIS)

    Koga, Hirofumi; Naito, Seiji; Fukui, Iwao; Tsukamoto, Taiji; Matsuoka, Naoki; Fujimoto, Hiroyuki

    2004-01-01

    The aim of this study is to estimate the feasibility of quality of life (QOL) research and to evaluate the QOL prospectively in locally advanced prostate cancer patients treated with hormonal treatment combined with radiotherapy. The treatment schedule was that patients with decreasing prostatic specific antigen (PSA) levels below 10 ng/ml after receiving 6 months of neoadjuvant hormonal treatment were randomly divided into two groups; one group was the continuous hormonal treatment group and the other was the intermittent hormonal treatment group. Both groups received a total dose of 72 Gy external beam radiotherapy with concomitant hormonal treatment followed by 6 months of adjuvant hormonal treatment following radiotherapy. At 14 months, patients either underwent continuous or intermittent hormonal treatment according to the random allocation. QOL was assessed at baseline, and at 6, 8, 14, and 20 months after treatment using functional assessment of cancer treatment-general (FACT-G), P with the other 3 items comprising bother of urination, bother of bowel movement, and bother of sexual activity. Between January 2000 and June 2003, a total of 188 patients were enrolled in this study. The rate of collection of baseline QOL sheets was 98.0%. The rate of answer to questions of QOL sheets was 99.0%. At baseline, the average score of FACT-G, P was 120.7 and the maximum score was more than twice the minimum score. Dysfunction of urination and bowel movement was correlated with the bother of urination and bowel movement, respectively. On the other hand, dysfunction of sexual activity was not correlated with the bother of sexual activity. In June 2003, all of the QOL sheets at baseline, and at 6, 8, and 14 months were completely collected from a total of 72 patients. Although QOL at 8 months was significantly affected compared with QOL at baseline and at 6 months, QOL at 14 months was significantly improved compared with that at 8 months and there was no significant

  13. ROBOT LITERACY AN APPROACH FOR SHARING SOCIETY WITH INTELLIGENT ROBOTS

    Directory of Open Access Journals (Sweden)

    Hidetsugu Suto

    2013-12-01

    Full Text Available A novel concept of media education called “robot literacy” is proposed. Here, robot literacy refers to the means of forming an appropriate relationship with intelligent robots. It can be considered a kind of media literacy. People who were born after the Internet age can be considered “digital natives” who have new morals and values and behave differently than previous generations in Internet societies. This can cause various problems among different generations. Thus, the necessity of media literacy education is increasing. Internet technologies, as well as robotics technologies are growing rapidly, and people who are born after the “home robot age,” whom the author calls “robot natives,” will be expected to have a certain degree of “robot literacy.” In this paper, the concept of robot literacy is defined and an approach to robot literacy education is discussed.

  14. Robotic buildings(s)

    NARCIS (Netherlands)

    Bier, H.H.

    2014-01-01

    Technological and conceptual advances in fields such as artificial intelligence, robotics, and material science have enabled robotic building to be in the last decade prototypically implemented. In this context, robotic building implies both physically built robotic environments and robotically

  15. Total robotic pancreaticoduodenectomy: a systematic review of the literature.

    Science.gov (United States)

    Kornaropoulos, Michail; Moris, Demetrios; Beal, Eliza W; Makris, Marinos C; Mitrousias, Apostolos; Petrou, Athanasios; Felekouras, Evangelos; Michalinos, Adamantios; Vailas, Michail; Schizas, Dimitrios; Papalampros, Alexandros

    2017-11-01

    Pancreaticoduodenectomy (PD) is a complex operation with high perioperative morbidity and mortality, even in the highest volume centers. Since the development of the robotic platform, the number of reports on robotic-assisted pancreatic surgery has been on the rise. This article reviews the current state of completely robotic PD. A systematic literature search was performed including studies published between January 2000 and July 2016 reporting PDs in which all procedural steps (dissection, resection and reconstruction) were performed robotically. Thirteen studies met the inclusion criteria, including a total of 738 patients. Data regarding perioperative outcomes such as operative time, blood loss, mortality, morbidity, conversion and oncologic outcomes were analyzed. No major differences were observed in mortality, morbidity and oncologic parameters, between robotic and non-robotic approaches. However, operative time was longer in robotic PD, whereas the estimated blood loss was lower. The conversion rate to laparotomy was 6.5-7.8%. Robotic PD is feasible and safe in high-volume institutions, where surgeons are experienced and medical staff are appropriately trained. Randomized controlled trials are required to further investigate outcomes of robotic PD. Additionally, cost analysis and data on long-term oncologic outcomes are needed to evaluate cost-effectiveness of the robotic approach in comparison with the open technique.

  16. User requirements for assistance of the supporting hand in bimanual daily activities via a robotic glove for severely affected stroke patients

    NARCIS (Netherlands)

    Prange, Grada Berendina; Smulders, Laura Cornelia; Smulders, L.C.; van Wijngaarden, J.; Lijbers, G.J.; Nijenhuis, Sharon Maria; Veltink, Petrus H.; Buurke, Jaap; Stienen, Arno; Braun, D.; Yu, H.; Campolo, D.

    2015-01-01

    For independent functioning in activities of daily life (ADL), proper hand function is paramount. Many stroke patients have a reduced ability to grasp and handle objects, while they don't fully recover functional use of the arm and hand, even after extensive (robotic) training. These patients may

  17. Cloud Robotics Platforms

    Directory of Open Access Journals (Sweden)

    Busra Koken

    2015-01-01

    Full Text Available Cloud robotics is a rapidly evolving field that allows robots to offload computation-intensive and storage-intensive jobs into the cloud. Robots are limited in terms of computational capacity, memory and storage. Cloud provides unlimited computation power, memory, storage and especially collaboration opportunity. Cloud-enabled robots are divided into two categories as standalone and networked robots. This article surveys cloud robotic platforms, standalone and networked robotic works such as grasping, simultaneous localization and mapping (SLAM and monitoring.

  18. Distributed Robotics Education

    DEFF Research Database (Denmark)

    Lund, Henrik Hautop; Pagliarini, Luigi

    2011-01-01

    Distributed robotics takes many forms, for instance, multirobots, modular robots, and self-reconfigurable robots. The understanding and development of such advanced robotic systems demand extensive knowledge in engineering and computer science. In this paper, we describe the concept of a distribu......Distributed robotics takes many forms, for instance, multirobots, modular robots, and self-reconfigurable robots. The understanding and development of such advanced robotic systems demand extensive knowledge in engineering and computer science. In this paper, we describe the concept...... to be changed, related to multirobot control and human-robot interaction control from virtual to physical representation. The proposed system is valuable for bringing a vast number of issues into education – such as parallel programming, distribution, communication protocols, master dependency, connectivity...

  19. The learning curve of robot-assisted laparoscopic aortofemoral bypass grafting for aortoiliac occlusive disease.

    Science.gov (United States)

    Novotný, Tomáš; Dvorák, Martin; Staffa, Robert

    2011-02-01

    Since the end of the 20th century, robot-assisted surgery has been finding its role among other minimally invasive methods. Vascular surgery seems to be another specialty in which the benefits of this technology can be expected. Our objective was to assess the learning curve of robot-assisted laparoscopic aortofemoral bypass grafting for aortoiliac occlusive disease in a group of 40 patients. Between May 2006 and January 2010, 40 patients (32 men, 8 women), who were a median age of 58 years (range, 48-75 years), underwent 40 robot-assisted laparoscopic aortofemoral reconstructions. Learning curve estimations were used for anastomosis, clamping, and operative time assessment. For conversion rate evaluation, the cumulative summation (CUSUM) technique was used. Statistical analysis comparing the first and second half of our group, and unilateral-to-bilateral reconstructions were performed. We created 21 aortofemoral and 19 aortobifemoral bypasses. The median proximal anastomosis time was 23 minutes (range, 18-50 minutes), median clamping time was 60 minutes (range, 40-95 minutes), and median operative time was 295 minutes (range, 180-475 minutes). The 30-day mortality rate was 0%, and no graft or wound infection or cardiopulmonary or hepatorenal complications were observed. During the median 18-month follow-up (range, 2-48 months), three early graft occlusions occurred (7%). After reoperations, the secondary patency of reconstructions was 100%. Data showed a typical short learning curve for robotic proximal anastomosis creation with anastomosis and clamping time reduction. The operative time learning curve was flat, confirming the procedure's complexity. There were two conversions to open surgery. CUSUM analysis confirmed that an acceptable conversion rate set at 5% was achieved. Comparing the first and second half of our group, all recorded times showed statistically significant improvements. Differences between unilateral and bilateral reconstructions were not

  20. A multichannel-near-infrared-spectroscopy-triggered robotic hand rehabilitation system for stroke patients.

    Science.gov (United States)

    Lee, Jongseung; Mukae, Nobutaka; Arata, Jumpei; Iwata, Hiroyuki; Iramina, Keiji; Iihara, Koji; Hashizume, Makoto

    2017-07-01

    There is a demand for a new neurorehabilitation modality with a brain-computer interface for stroke patients with insufficient or no remaining hand motor function. We previously developed a robotic hand rehabilitation system triggered by multichannel near-infrared spectroscopy (NIRS) to address this demand. In a preliminary prototype system, a robotic hand orthosis, providing one degree-of-freedom motion for a hand's closing and opening, is triggered by a wireless command from a NIRS system, capturing a subject's motor cortex activation. To examine the feasibility of the prototype, we conducted a preliminary test involving six neurologically intact participants. The test comprised a series of evaluations for two aspects of neurorehabilitation training in a real-time manner: classification accuracy and execution time. The effects of classification-related factors, namely the algorithm, signal type, and number of NIRS channels, were investigated. In the comparison of algorithms, linear discrimination analysis performed better than the support vector machine in terms of both accuracy and training time. The oxyhemoglobin versus deoxyhemoglobin comparison revealed that the two concentrations almost equally contribute to the hand motion estimation. The relationship between the number of NIRS channels and accuracy indicated that a certain number of channels are needed and suggested a need for a method of selecting informative channels. The computation time of 5.84 ms was acceptable for our purpose. Overall, the preliminary prototype showed sufficient feasibility for further development and clinical testing with stroke patients.

  1. Robot Mechanisms

    CERN Document Server

    Lenarcic, Jadran; Stanišić, Michael M

    2013-01-01

    This book provides a comprehensive introduction to the area of robot mechanisms, primarily considering industrial manipulators and humanoid arms. The book is intended for both teaching and self-study. Emphasis is given to the fundamentals of kinematic analysis and the design of robot mechanisms. The coverage of topics is untypical. The focus is on robot kinematics. The book creates a balance between theoretical and practical aspects in the development and application of robot mechanisms, and includes the latest achievements and trends in robot science and technology.

  2. Robots de servicio

    Directory of Open Access Journals (Sweden)

    Rafael Aracil

    2008-04-01

    Full Text Available Resumen: El término Robots de Servicio apareció a finales de los años 80 como una necesidad de desarrollar máquinas y sistemas capaces de trabajar en entornos diferentes a los fabriles. Los Robots de Servicio tenían que poder trabajar en entornos noestructurados, en condiciones ambientales cambiantes y con una estrecha interacción con los humanos. En 1995 fue creado por la IEEE Robotics and Automation Society, el Technical Committee on Service Robots, y este comité definió en el año 2000 las áreas de aplicación de los Robots de Servicios, que se pueden dividir en dos grandes grupos: 1 sectores productivos no manufactureros tales como edificación, agricultura, naval, minería, medicina, etc. y 2 sectores de servicios propiamente dichos: asistencia personal, limpieza, vigilancia, educación, entretenimiento, etc. En este trabajo se hace una breve revisión de los principales conceptos y aplicaciones de los robots de servicio. Palabras clave: Robots de servicio, robots autónomos, robots de exteriores, robots de educación y entretenimiento, robots caminantes y escaladores, robots humanoides

  3. Filigree Robotics

    DEFF Research Database (Denmark)

    Tamke, Martin; Evers, Henrik Leander; Clausen Nørgaard, Esben

    2016-01-01

    Filigree Robotics experiments with the combination of traditional ceramic craft with robotic fabrication in order to generate a new narrative of fine three-dimensional ceramic ornament for architecture.......Filigree Robotics experiments with the combination of traditional ceramic craft with robotic fabrication in order to generate a new narrative of fine three-dimensional ceramic ornament for architecture....

  4. The Development of Robotic Technology in Cardiac and Vascular Interventions

    Directory of Open Access Journals (Sweden)

    Ali Pourdjabbar

    2017-07-01

    Full Text Available Robotic technology has been used in cardiovascular medicine for over a decade, and over that period its use has been expanded to interventional cardiology and percutaneous coronary and peripheral vascular interventions. The safety and feasibility of robotically assisted interventions has been demonstrated in multiple studies ranging from simple to complex coronary lesions, and in the treatment of iliofemoral and infrapopliteal disease. These studies have shown a reduction in operator exposure to harmful ionizing radiation, and the use of robotics has the intuitive benefit of alleviating the occupational hazard of operator orthopedic injuries. In addition to the interventional operator benefits, robotically assisted intervention has the potential to also be beneficial for patients by allowing more accurate lesion length measurement, stent placement, and patient radiation exposure; however, more investigation is required to elucidate these benefits fully.

  5. Hydraulic bilateral construction robot; Yuatsushiki bilateral kensetsu robot

    Energy Technology Data Exchange (ETDEWEB)

    Maehata, K.; Mori, N. [Kayaba Industry Co. Ltd., Tokyo (Japan)

    1999-05-15

    Concerning a hydraulic bilateral construction robot, its system constitution, structures and functions of important components, and the results of some tests are explained, and the researches conducted at Gifu University are described. The construction robot in this report is a servo controlled system of a version developed from the mini-shovel now available in the market. It is equipped, in addition to an electrohydraulic servo control system, with various sensors for detecting the robot attitude, vibration, and load state, and with a camera for visualizing the surrounding landscape. It is also provided with a bilateral joy stick which is a remote control actuator capable of working sensation feedback and with a rocking unit that creates robot movements of rolling, pitching, and heaving. The construction robot discussed here, with output increased and response faster thanks to the employment of a hydraulic driving system for the aim of building a robot system superior in performance to the conventional model designed primarily for heavy duty, proves after tests to be a highly sophisticated remotely controlled robot control system. (NEDO)

  6. ROBOT-ASSISTED RADICAL PROSTATECTOMY: ANALYSIS OF THE FIRST 80 CASES

    Directory of Open Access Journals (Sweden)

    D. Yu. Pushkar

    2010-01-01

    Full Text Available Background. As a common disease, prostate cancer (PC has taken now first place among all malignancies in many countries of the world.The authors have analyzed the results of their series of robot-assisted radical laparoscopic prostatectomy (RALP in patients with PC. They also present a number of surgical techniques that may be useful for novice surgeons. Materials and methods. In November 2008 to November 2009, the Department of Urology, Moscow State University of Medicine and Dentistry, performed 80 RALPs using the da Vinci S surgical robotic system. The patients’ mean age was 63.7 (49–71 years; the mean blood level of total prostate-specific antigen was 6.1 (2.1–20.84 ng/ml; the mean prostate volume was 44 (18–94 cm3, as evidenced by transrectal ultrasound study. The authors analyzed the following indicators: operating time, degree of blood loss, conversion of surgical intervention,degrees of intra- and postoperative complications, and oncological and functional results. Results. In our series, RALP was performed without preserving neurovascular bundles or by using a nerve-sparing procedure in 66 (82.5% and 14 (17.5%, respectively; 22 (27.5% patients underwent lymphadenectomy. The average length of hospital stay was 7 (4–21 days; the mean time of urethral catheter removal was 10 (6–21 days postoperatively. The mean time of surgical intervention was 174 (121–276 min. Mean blood loss was 248 (35–1950 ml. Postmortem study revealed a positive surgical margin in 19 (24% cases and tumor invasion into the seminal vesicles in 5 (6% patients. Stages pT2 and pT3 were found in 56 (70% and 24 (30%, respectively; total Gleason scores were 6 (3+3, 7 (3+4, 7 (4+3, 8 (4+4 in 38 (47.5%, 35 (43.75%, 5 (6.25%, and 2 (2.5% patients, respectively. Among 34 patients examined 3 months after RALP, 28 (82.4% patients completely retained urine; 5 (14.7% applied not more than a pad a day. In patients with preserved erectile function, the

  7. Robotics education

    International Nuclear Information System (INIS)

    Benton, O.

    1984-01-01

    Robotics education courses are rapidly spreading throughout the nation's colleges and universities. Engineering schools are offering robotics courses as part of their mechanical or manufacturing engineering degree program. Two year colleges are developing an Associate Degree in robotics. In addition to regular courses, colleges are offering seminars in robotics and related fields. These seminars draw excellent participation at costs running up to $200 per day for each participant. The last one drew 275 people from Texas to Virginia. Seminars are also offered by trade associations, private consulting firms, and robot vendors. IBM, for example, has the Robotic Assembly Institute in Boca Raton and charges about $1,000 per week for course. This is basically for owners of IBM robots. Education (and training) can be as short as one day or as long as two years. Here is the educational pattern that is developing now

  8. The first nationwide evaluation of robotic general surgery: a regionalized, small but safe start.

    Science.gov (United States)

    Wormer, Blair A; Dacey, Kristian T; Williams, Kristopher B; Bradley, Joel F; Walters, Amanda L; Augenstein, Vedra A; Stefanidis, Dimitrios; Heniford, B Todd

    2014-03-01

    The purpose of this study was to evaluate the outcomes of the most commonly performed robotic-assisted general surgery (RAGS) procedures in a nationwide database and compare them with their laparoscopic counterparts. The Nationwide Inpatient Sample was queried from October 2008 to December 2010 for patients undergoing elective, abdominal RAGS procedures. The two most common, robotic-assisted fundoplication (RF) and gastroenterostomy without gastrectomy (RG), were individually compared with the laparoscopic counterparts (LF and LG, respectively). During the study, 297,335 patients underwent abdominal general surgery procedures, in which 1,809 (0.6 %) utilized robotic-assistance. From 2009 to 2010, the incidence of RAGS nearly doubled from 573 to 1128 cases. The top five RAGS procedures by frequency were LG, LF, laparoscopic lysis of adhesions, other anterior resection of rectum, and laparoscopic sigmoidectomy. Eight of the top ten RAGS were colorectal or foregut operations. RG was performed in 282 patients (0.9 %) and LG in 29,677 patients (99.1 %). When comparing RG with LG there was no difference in age, gender, race, Charlson comorbidity index (CCI), postoperative complications, or mortality; however, length of stay (LOS) was longer in RG (2.5 ± 2.4 vs. 2.2 ± 1.5 days; p < 0.0001). Total cost for RG was substantially higher ($60,837 ± 28,887 vs. $42,743 ± 23,366; p < 0.0001), and more often performed at teaching hospitals (87.2 vs. 50.9 %; p < 0.0001) in urban areas (100 vs. 93.0 %; p < 0.0001). RF was performed in 272 patients (3.5 %) and LF in 7,484 patients (96.5 %). RF patients were more often male compared with LF (38.2 vs. 32.3 %; p < 0.05); however, there was no difference in age, race, CCI, LOS, or postoperative complications. RF was more expensive than LF ($37,638 ± 21,134 vs. $32,947 ± 24,052; p < 0.0001), and more often performed at teaching hospitals (72.4 vs. 54.9 %; p < 0.0001) in urban areas (98.5 vs. 88.7 %; p < 0.0001). This nationwide

  9. Robotic-assisted laparoscopic surgery: recent advances in urology.

    Science.gov (United States)

    Autorino, Riccardo; Zargar, Homayoun; Kaouk, Jihad H

    2014-10-01

    The aim of the present review is to summarize recent developments in the field of urologic robotic surgery. A nonsystematic literature review was performed to retrieve publications related to robotic surgery in urology and evidence-based critical analysis was conducted by focusing on the literature of the past 5 years. The use of the da Vinci Surgical System, a robotic surgical system, has been implemented for the entire spectrum of extirpative and reconstructive laparoscopic kidney procedures. The robotic approach can be applied for a range of adrenal indications as well as for ureteral diseases, including benign and malignant conditions affecting the proximal, mid, and distal ureter. Current evidence suggests that robotic prostatectomy is associated with less blood loss compared with the open surgery. Besides prostate cancer, robotics has been used for simple prostatectomy in patients with symptomatic benign prostatic hyperplasia. Recent studies suggest that minimally invasive radical cystectomy provides encouraging oncologic outcomes mirroring those reported for open surgery. In recent years, the evolution of robotic surgery has enabled urologic surgeons to perform urinary diversions intracorporeally. Robotic vasectomy reversal and several other robotic andrological applications are being explored. In summary, robotic-assisted surgery is an emerging and safe technology for most urologic operations. The acceptance of robotic prostatectomy during the past decade has paved the way for urologists to explore the entire spectrum of extirpative and reconstructive urologic procedures. Cost remains a significant issue that could be solved by wider dissemination of the technology. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  10. Robotic simple prostatectomy: A consideration for large prostate adenomas

    Directory of Open Access Journals (Sweden)

    Joshua B. Nething

    2014-12-01

    Full Text Available Background: The management of benign prostatic hyperplasia (BPH has changed considerably over the last several decades. First line treatment of BPH and lower urinary tract symptoms (LUTS with medical therapy has created a population of men with much larger prostate glands, many of whom require surgical intervention. Patients with prostate glands greater than 80 to 100 grams may be better managed surgically with a retropubic prostatectomy. We explore our experience with robotic assisted simple prostatectomy and review the relevant literature. Database: The database reviewed includes our experience with seven patients undergoing robotic simple prostatectomy, and a comprehensive review of the previously published series of this procedure. In addition, the literature pertaining to a pure laparoscopic approach to simple prostatectomy is reviewed. Conclusion: Robotic experience and training has become a standard in resident training programs; while classic transurethral resection is being performed less for large prostate glands. The robotic approach to simple prostatectomy provides an excellent option for surgical treatment of very large prostate glands, providing patients acceptable results in terms of operative time, estimated blood loss, hospital stay and duration of Foley catheter.

  11. Robotic surgery in complicated gynecologic diseases: experience of Tri-Service General Hospital in Taiwan.

    Science.gov (United States)

    Tan, Shun-Jen; Lin, Chi-Kung; Fu, Pei-Te; Liu, Yung-Liang; Sun, Cheng-Chian; Chang, Cheng-Chang; Yu, Mu-Hsien; Lai, Hung-Cheng

    2012-03-01

    Minimally invasive surgery has been the trend in various specialties and continues to evolve as new technology develops. The development of robotic surgery in gynecology remains in its infancy. The present study reports the first descriptive series of robotic surgery in complicated gynecologic diseases in Taiwan. From March 2009 to February 2011, the records of patients undergoing robotic surgery using the da Vinci Surgical System were reviewed for patient demographics, indications, operative time, hospital stay, conversion to laparotomy, and complications. Sixty cases were reviewed in the present study. Forty-nine patients had benign gynecologic diseases, and 11 patients had malignancies. These robot-assisted laparoscopic procedures include nine hysterectomy, 15 subtotal hysterectomy, 13 myomectomy, eight staging operation, two radical hysterectomy, five ovarian cystectomy, one bilateral salpingo-oophorectomy and myomectomy, two resections of deep pelvic endometriosis, one pelvic adhesiolysis, three sacrocolpopexy and one tuboplasty. Thirty-three patients had prior pelvic surgery, and one had a history of pelvic radiotherapy. Adhesiolysis was necessary in 38 patients to complete the whole operation. Robotic myomectomy was easily accomplished in patients with huge uterus or multiple myomas. The suturing of myometrium or cervical stump after ligation of the uterine arteries minimized the blood loss. In addition, it was much easier to dissect severe pelvic adhesions. The dissection of para-aortic lymph nodes can be easily accomplished. All these surgeries were performed smoothly without ureteral, bladder or bowel injury. The present analyses include various complicated gynecologic conditions, which make the estimation of the effectiveness of robotic surgery in each situation individually not appropriate. However, our experiences do show that robotic surgery is feasible and safe for patients with complicated gynecologic diseases. Copyright © 2012. Published by

  12. Lingual Thyroid Excision with Transoral Robotic Surgery

    Directory of Open Access Journals (Sweden)

    Elif Ersoy Callıoglu

    2015-01-01

    Full Text Available Ectopic thyroid gland may be detected at any place between foramen caecaum and normal thyroid localization due to inadequacy of the embryological migration of the thyroid gland. It has a prevalence varying between 1/10.000 and 1/100000 in the community. Usually follow-up without treatment is preferred except for obstructive symptoms, bleeding, and suspicion of malignity. Main symptoms are dysphagia, dysphonia, bleeding, dyspnea, and obstructive sleep apnea. In symptomatic cases, the first described method in surgical treatment is open approach since it is a region difficult to have access to. However, this approach has an increased risk of morbidity and postoperative complications. Transoral robotic surgery, which is a minimally invasive surgical procedure, has advantages such as larger three-dimensional point of view and ease of manipulation due to robotic instruments. In this report, a case at the age of 49 who presented to our clinic with obstructive symptoms increasing within the last year and was found to have lingual thyroid and underwent excision of ectopic thyroid tissue by da Vinci surgical system is presented.

  13. Robot Aesthetics

    DEFF Research Database (Denmark)

    Jochum, Elizabeth Ann; Putnam, Lance Jonathan

    This paper considers art-based research practice in robotics through a discussion of our course and relevant research projects in autonomous art. The undergraduate course integrates basic concepts of computer science, robotic art, live performance and aesthetic theory. Through practice...... in robotics research (such as aesthetics, culture and perception), we believe robot aesthetics is an important area for research in contemporary aesthetics....

  14. Analysis of secondary cytoreduction for recurrent ovarian cancer by robotics, laparoscopy and laparotomy.

    Science.gov (United States)

    Magrina, Javier F; Cetta, Rachel L; Chang, Yu-Hui; Guevara, Gregory; Magtibay, Paul M

    2013-05-01

    Analysis of perioperative outcomes and survival of patients with recurrent ovarian cancer undergoing secondary cytoreduction by robotics, laparoscopy, or laparotomy. Retrospective analysis of 52 selected patients with recurrent ovarian cancer undergoing secondary cytoreduction by laparoscopy (9), laparotomy (33) or robotics (10) between January 2006 and December 2010. Comparison was made by a total of 21 factors including age, BMI, number of previous surgeries, tumor type and grade, number of procedures, and 15 types of procedures performed at secondary cytoreduction. For all patients, the mean operating time was 213.8 min, mean blood loss 657.4 ml; and mean hospital stay 7.5 days. Complete debulking was achieved in 75% of patients. Postoperative complications were noted in 36.5% of patients. Overall and progression-free survival at 3-years were 58.8% and 34.1%, respectively. Laparoscopy and robotics had reduced blood loss and hospital stay, while no differences were observed among the three groups for operating time, complications, complete debulking, and survival. Selected patients with recurrent ovarian cancer benefit from a laparoscopic or robotic secondary cytoreduction without compromising survival. Robotics and laparoscopy provide similar perioperative outcomes, and reduced blood loss and shorter hospital stay as compared to laparotomy. Laparotomy seems preferable for patients with widespread peritoneal implants, multiple sites of recurrence, and/or extensive adhesions. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Endowrist versus wrist: a case-controlled study comparing robotic versus hand-assisted laparoscopic surgery for rectal cancer.

    Science.gov (United States)

    Koh, Frederick H X; Tan, Ker-Kan; Lieske, Bettina; Tsang, Marianne L; Tsang, Charles B; Koh, Dean C

    2014-10-01

    Laparoscopic total mesorectal excision (TME) remains a technically challenging procedure. This study aims to compare the surgical outcomes of the robotic-assisted laparoscopic (RAL) versus hand-assisted laparoscopic (HAL) techniques in performing TME for patients with rectal cancers. A retrospective review of all patients who underwent RAL TME for rectal cancers was performed. These cases were matched for age, sex, and stage of malignancy with patients who underwent HAL TME. Data collected included age, sex, American Society of Anesthesiologists scores, comorbid conditions, types of surgical resections and operative times, perioperative complications, length of hospital stays, and histopathologic outcomes were analyzed. From August 2008 to August 2011, 19 patients, with a median age of 62 (range, 47 to 92) years underwent RAL TME. Eight (42.1%) patients received neoadjuvant chemoradiotherapy. The median docking and operative times were 10 (range, 3 to 34) and 390 (range, 289 to 771) minutes, respectively. There was 1 (5.3%) conversion to open surgery. The grade of mesorectal excision was histopathologically reported as complete in all 19 cases. Positive circumferential margin was reported in 1 (5.3%) patient.Comparing the 2 groups, more patients in the RAL group received neoadjuvant chemoradiotherapy (8 vs. 3; P=0.048). The operative times were longer in the RAL group (390 vs. 225 min; P<0.001). A higher proportion of patients in the HAL group required conversion to open surgery (5 vs. 1; P=0.180) and developed perioperative morbidities (3 vs. 7; P=0.269). The median length of hospitalization was comparable between both groups (RAL: 7 vs. HAL: 6 d; P=0.476).The procedural cost was significantly higher in the RAL group (US$12,460 vs. US$8560; P<0.001), whereas the nonprocedural cost remained comparable between the 2 groups (RAL: US$4470 vs. HAL: US$4500; P=0.729). RAL TME is associated with lower conversion and morbidity rates compared with HAL TME. The longer

  16. Designing robots for care: care centered value-sensitive design.

    Science.gov (United States)

    van Wynsberghe, Aimee

    2013-06-01

    The prospective robots in healthcare intended to be included within the conclave of the nurse-patient relationship--what I refer to as care robots--require rigorous ethical reflection to ensure their design and introduction do not impede the promotion of values and the dignity of patients at such a vulnerable and sensitive time in their lives. The ethical evaluation of care robots requires insight into the values at stake in the healthcare tradition. What's more, given the stage of their development and lack of standards provided by the International Organization for Standardization to guide their development, ethics ought to be included into the design process of such robots. The manner in which this may be accomplished, as presented here, uses the blueprint of the Value-sensitive design approach as a means for creating a framework tailored to care contexts. Using care values as the foundational values to be integrated into a technology and using the elements in care, from the care ethics perspective, as the normative criteria, the resulting approach may be referred to as care centered value-sensitive design. The framework proposed here allows for the ethical evaluation of care robots both retrospectively and prospectively. By evaluating care robots in this way, we may ultimately ask what kind of care we, as a society, want to provide in the future.

  17. Robot-assisted pancreatic surgery: a systematic review of the literature

    Science.gov (United States)

    Strijker, Marin; van Santvoort, Hjalmar C; Besselink, Marc G; van Hillegersberg, Richard; Borel Rinkes, Inne HM; Vriens, Menno R; Molenaar, I Quintus

    2013-01-01

    Background To potentially improve outcomes in pancreatic resection, robot-assisted pancreatic surgery has been introduced. This technique has possible advantages over laparoscopic surgery, such as its affordance of three-dimensional vision and increased freedom of movement of instruments. A systematic review was performed to assess the safety and feasibility of robot-assisted pancreatic surgery. Methods The literature published up to 30 September 2011 was systematically reviewed, with no restrictions on publication date. Studies reporting on over five patients were included. Animal studies, studies not reporting morbidity and mortality, review articles and conference abstracts were excluded. Data were extracted and weighted means were calculated. Results A total of 499 studies were screened, after which eight cohort studies reporting on a total of 251 patients undergoing robot-assisted pancreatic surgery were retained for analysis. Weighted mean operation time was 404 ± 102 min (510 ± 107 min for pancreatoduodenectomy only). The rate of conversion was 11.0% (16.4% for pancreatoduodenectomy only). Overall morbidity was 30.7% (n = 77), most frequently involving pancreatic fistulae (n = 46). Mortality was 1.6%. Negative surgical margins were obtained in 92.9% of patients. The rate of spleen preservation in distal pancreatectomy was 87.1%. Conclusions Robot-assisted pancreatic surgery seems to be safe and feasible in selected patients and, in left-sided resections, may increase the rate of spleen preservation. Randomized studies should compare the respective outcomes of robot-assisted, laparoscopic and open pancreatic surgery. PMID:23216773

  18. Robots: l'embarras de richesses [:survey of robots available

    International Nuclear Information System (INIS)

    Meieran, H.; Brittain, K.; Sturkey, R.

    1989-01-01

    A survey of robots available for use in the nuclear industry is presented. Two new categories of mobile robots have been introduced since the last survey (April 1987): pipe crawlers and underwater robots. The number of robots available has risen to double what it was two years ago and four times what it was in 1986. (U.K.)

  19. Robotic surgery in Italy national survey (2011).

    Science.gov (United States)

    Santoro, Eugenio; Pansadoro, Vito

    2013-03-01

    Robotic surgery in Italy has become a clinical reality that is gaining increasing acceptance. As of 2011 after the United States, Italy together with Germany is the country with the largest number of active Robotic centers, 46, and da Vinci Robots installed, with at least 116 operators already trained. The number of interventions performed in Italy in 2011 exceeded 6,000 and in 2010 were 4,784, with prevalence for urology, general surgery and gynecology, however these interventions have also begun to be applied in other fields such as cervicofacial, cardiothoracic and pediatric surgery. In Italy Robotic centers are mostly located in Northern Italy, while in the South there are only a few centers, and four regions are lacking altogether. Of the 46 centers which were started in 1999, the vast majority is still operational and almost half handle over 200 cases a year. The quality of the work is also especially high with large diffusion of radical prostatectomy in urology and liver resection and colic in general surgery. The method is very well accepted among operators, over 80 %, and among patients, over 95 %. From the analysis of world literature and a survey carried out in Italy, Robotic surgery, which at the moment could be better defined as telesurgery, represents a significant advantage for operators and a consistent gain for the patient. However, it still has important limits such as high cost and non-structured training of operators.

  20. Robots Social Embodiment in Autonomous Mobile Robotics

    Directory of Open Access Journals (Sweden)

    Brian Duffy

    2008-11-01

    Full Text Available This work aims at demonstrating the inherent advantages of embracing a strong notion of social embodiment in designing a real-world robot control architecture with explicit ?intelligent? social behaviour between a collective of robots. It develops the current thinking on embodiment beyond the physical by demonstrating the importance of social embodiment. A social framework develops the fundamental social attributes found when more than one robot co-inhabit a physical space. The social metaphors of identity, character, stereotypes and roles are presented and implemented within a real-world social robot paradigm in order to facilitate the realisation of explicit social goals.