  1. Evaluation of positioning errors of the patient using cone beam CT megavoltage

    International Nuclear Information System (INIS)

    Garcia Ruiz-Zorrilla, J.; Fernandez Leton, J. P.; Zucca Aparicio, D.; Perez Moreno, J. M.; Minambres Moro, A.

    2013-01-01

    Image-guided radiation therapy allows you to assess and fix the positioning of the patient in the treatment unit, thus reducing the uncertainties due to the positioning of the patient. This work assesses errors systematic and errors of randomness from the corrections made to a series of patients of different diseases through a protocol off line of cone beam CT (CBCT) megavoltage. (Author)

  2. Reduction in specimen labeling errors after implementation of a positive patient identification system in phlebotomy.

    Science.gov (United States)

    Morrison, Aileen P; Tanasijevic, Milenko J; Goonan, Ellen M; Lobo, Margaret M; Bates, Michael M; Lipsitz, Stuart R; Bates, David W; Melanson, Stacy E F

    2010-06-01

    Ensuring accurate patient identification is central to preventing medical errors, but it can be challenging. We implemented a bar code-based positive patient identification system for use in inpatient phlebotomy. A before-after design was used to evaluate the impact of the identification system on the frequency of mislabeled and unlabeled samples reported in our laboratory. Labeling errors fell from 5.45 in 10,000 before implementation to 3.2 in 10,000 afterward (P = .0013). An estimated 108 mislabeling events were prevented by the identification system in 1 year. Furthermore, a workflow step requiring manual preprinting of labels, which was accompanied by potential labeling errors in about one quarter of blood "draws," was removed as a result of the new system. After implementation, a higher percentage of patients reported having their wristband checked before phlebotomy. Bar code technology significantly reduced the rate of specimen identification errors.

  3. Evaluation of positioning errors of the patient using cone beam CT megavoltage; Evaluacion de errores de posicionamiento del paciente mediante Cone Beam CT de megavoltaje

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Ruiz-Zorrilla, J.; Fernandez Leton, J. P.; Zucca Aparicio, D.; Perez Moreno, J. M.; Minambres Moro, A.

    2013-07-01

    Image-guided radiation therapy allows you to assess and fix the positioning of the patient in the treatment unit, thus reducing the uncertainties due to the positioning of the patient. This work assesses errors systematic and errors of randomness from the corrections made to a series of patients of different diseases through a protocol off line of cone beam CT (CBCT) megavoltage. (Author)

  4. Automatic detection of patient identification and positioning errors in radiotherapy treatment using 3D setup images

    OpenAIRE

    Jani, Shyam

    2015-01-01

    The success of modern radiotherapy treatment depends on the correct alignment of the radiation beams with the target region in the patient. In the conventional paradigm of image-guided radiation therapy, 2D or 3D setup images are taken immediately prior to treatment and are used by radiation therapy technologists to localize the patient to the same position as defined from the reference planning CT dataset. However, numerous reports in the literature have described errors during this step, wh...

  5. Implication of spot position error on plan quality and patient safety in pencil-beam-scanning proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Juan; Beltran, Chris J., E-mail: beltran.chris@mayo.edu; Herman, Michael G. [Division of Medical Physics, Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2014-08-15

    Purpose: To quantitatively and systematically assess dosimetric effects induced by spot positioning error as a function of spot spacing (SS) on intensity-modulated proton therapy (IMPT) plan quality and to facilitate evaluation of safety tolerance limits on spot position. Methods: Spot position errors (PE) ranging from 1 to 2 mm were simulated. Simple plans were created on a water phantom, and IMPT plans were calculated on two pediatric patients with a brain tumor of 28 and 3 cc, respectively, using a commercial planning system. For the phantom, a uniform dose was delivered to targets located at different depths from 10 to 20 cm with various field sizes from 2{sup 2} to 15{sup 2} cm{sup 2}. Two nominal spot sizes, 4.0 and 6.6 mm of 1 σ in water at isocenter, were used for treatment planning. The SS ranged from 0.5 σ to 1.5 σ, which is 2–6 mm for the small spot size and 3.3–9.9 mm for the large spot size. Various perturbation scenarios of a single spot error and systematic and random multiple spot errors were studied. To quantify the dosimetric effects, percent dose error (PDE) depth profiles and the value of percent dose error at the maximum dose difference (PDE [ΔDmax]) were used for evaluation. Results: A pair of hot and cold spots was created per spot shift. PDE[ΔDmax] is found to be a complex function of PE, SS, spot size, depth, and global spot distribution that can be well defined in simple models. For volumetric targets, the PDE [ΔDmax] is not noticeably affected by the change of field size or target volume within the studied ranges. In general, reducing SS decreased the dose error. For the facility studied, given a single spot error with a PE of 1.2 mm and for both spot sizes, a SS of 1σ resulted in a 2% maximum dose error; a SS larger than 1.25 σ substantially increased the dose error and its sensitivity to PE. A similar trend was observed in multiple spot errors (both systematic and random errors). Systematic PE can lead to noticeable hot

  6. [Medical errors from positions of mutual relations of patient-lawyer-doctor].

    Science.gov (United States)

    Radysh, Ia F; Tsema, Ie V; Mehed', V P

    2013-01-01

    The basic theoretical and practical aspects of problem of malpractice in the system of health protection Ukraine are presented in the article. On specific examples the essence of the term "malpractice" is expounded. It was considered types of malpractice, conditions of beginning and kinds of responsibility to assumption of malpractice. The special attention to the legal and mental and ethical questions of problem from positions of protection of rights for a patient and medical worker is spared. The necessity of qualification malpractices on intentional and unintentional, possible and impermissible is grounded.

  7. Automatic detection of patient identification and positioning errors in radiation therapy treatment using 3-dimensional setup images.

    Science.gov (United States)

    Jani, Shyam S; Low, Daniel A; Lamb, James M

    2015-01-01

    To develop an automated system that detects patient identification and positioning errors between 3-dimensional computed tomography (CT) and kilovoltage CT planning images. Planning kilovoltage CT images were collected for head and neck (H&N), pelvis, and spine treatments with corresponding 3-dimensional cone beam CT and megavoltage CT setup images from TrueBeam and TomoTherapy units, respectively. Patient identification errors were simulated by registering setup and planning images from different patients. For positioning errors, setup and planning images were misaligned by 1 to 5 cm in the 6 anatomical directions for H&N and pelvis patients. Spinal misalignments were simulated by misaligning to adjacent vertebral bodies. Image pairs were assessed using commonly used image similarity metrics as well as custom-designed metrics. Linear discriminant analysis classification models were trained and tested on the imaging datasets, and misclassification error (MCE), sensitivity, and specificity parameters were estimated using 10-fold cross-validation. For patient identification, our workflow produced MCE estimates of 0.66%, 1.67%, and 0% for H&N, pelvis, and spine TomoTherapy images, respectively. Sensitivity and specificity ranged from 97.5% to 100%. MCEs of 3.5%, 2.3%, and 2.1% were obtained for TrueBeam images of the above sites, respectively, with sensitivity and specificity estimates between 95.4% and 97.7%. MCEs for 1-cm H&N/pelvis misalignments were 1.3%/5.1% and 9.1%/8.6% for TomoTherapy and TrueBeam images, respectively. Two-centimeter MCE estimates were 0.4%/1.6% and 3.1/3.2%, respectively. MCEs for vertebral body misalignments were 4.8% and 3.6% for TomoTherapy and TrueBeam images, respectively. Patient identification and gross misalignment errors can be robustly and automatically detected using 3-dimensional setup images of different energies across 3 commonly treated anatomical sites. Copyright © 2015 American Society for Radiation Oncology. Published by

  8. Setup accuracy of stereoscopic X-ray positioning with automated correction for rotational errors in patients treated with conformal arc radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Soete, Guy; Verellen, Dirk; Tournel, Koen; Storme, Guy

    2006-01-01

    We evaluated setup accuracy of NovalisBody stereoscopic X-ray positioning with automated correction for rotational errors with the Robotics Tilt Module in patients treated with conformal arc radiotherapy for prostate cancer. The correction of rotational errors was shown to reduce random and systematic errors in all directions. (NovalisBody TM and Robotics Tilt Module TM are products of BrainLAB A.G., Heimstetten, Germany)

  9. Position Error Covariance Matrix Validation and Correction

    Science.gov (United States)

    Frisbee, Joe, Jr.

    2016-01-01

    In order to calculate operationally accurate collision probabilities, the position error covariance matrices predicted at times of closest approach must be sufficiently accurate representations of the position uncertainties. This presentation will discuss why the Gaussian distribution is a reasonable expectation for the position uncertainty and how this assumed distribution type is used in the validation and correction of position error covariance matrices.

  10. Set-up error in supine-positioned patients immobilized with two different modalities during conformal radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Fiorino, C.; Cattaneo, G.M.; Calandrino, R.; Reni, M.; Bolognesi, A.; Bonini, A.

    1998-01-01

    Background: Conformal radiotherapy requires reduced margins around the clinical target volume (CTV) with respect to traditional radiotherapy techniques. Therefore, high set-up accuracy and reproducibility are mandatory. Purpose: To investigate the effectiveness of two different immobilization techniques during conformal radiotherapy of prostate cancer with small fields. Materials and methods: 52 patients with prostate cancer were treated by conformal three- or four-field techniques with radical or adjuvant intent between November 1996 and March 1998. In total, 539 portal images were collected on a weekly basis for at least the first 4 weeks of the treatment on lateral and anterior 18 MV X-ray fields. The average number of sessions monitored per patient was 5.7 (range 4-10). All patients were immobilized with an alpha-cradle system; 25 of them were immobilized at the pelvis level (group A) and the remaining 27 patients were immobilized in the legs (group B). The shifts with respect to the simulation condition were assessed by measuring the distances between the same bony landmarks and the field edges. The global distributions of cranio-caudal (CC), posterior-anterior (PA) and left-right (LR) shifts were considered; for each patient random and systematic error components were assessed by following the procedure suggested by Bijhold et al. (Bijhold J, Lebesque JV, Hart AAM, Vijlbrief RE. Maximising set-up accuracy using portal images as applied to a conformal boost technique for prostatic cancer. Radiother. Oncol. 1992;24:261-271). For each patient the average isocentre (3D) shift was assessed as the quadratic sum of the average shifts in the three directions. Results 5 mm equal to 4.4% with respect to the 21.6% of group A (P<0.0001). This value was also better than the corresponding value found in a previously investigated group of 21 non-immobilized patients (Italia C, Fiorino C, Ciocca M, et al. Quality control by portal film analysis of the conformal radiotherapy

  11. Reward positivity: Reward prediction error or salience prediction error?

    Science.gov (United States)

    Heydari, Sepideh; Holroyd, Clay B

    2016-08-01

    The reward positivity is a component of the human ERP elicited by feedback stimuli in trial-and-error learning and guessing tasks. A prominent theory holds that the reward positivity reflects a reward prediction error signal that is sensitive to outcome valence, being larger for unexpected positive events relative to unexpected negative events (Holroyd & Coles, 2002). Although the theory has found substantial empirical support, most of these studies have utilized either monetary or performance feedback to test the hypothesis. However, in apparent contradiction to the theory, a recent study found that unexpected physical punishments also elicit the reward positivity (Talmi, Atkinson, & El-Deredy, 2013). The authors of this report argued that the reward positivity reflects a salience prediction error rather than a reward prediction error. To investigate this finding further, in the present study participants navigated a virtual T maze and received feedback on each trial under two conditions. In a reward condition, the feedback indicated that they would either receive a monetary reward or not and in a punishment condition the feedback indicated that they would receive a small shock or not. We found that the feedback stimuli elicited a typical reward positivity in the reward condition and an apparently delayed reward positivity in the punishment condition. Importantly, this signal was more positive to the stimuli that predicted the omission of a possible punishment relative to stimuli that predicted a forthcoming punishment, which is inconsistent with the salience hypothesis. © 2016 Society for Psychophysiological Research.

  12. Sources of Error in Satellite Navigation Positioning

    Directory of Open Access Journals (Sweden)

    Jacek Januszewski

    2017-09-01

    Full Text Available An uninterrupted information about the user’s position can be obtained generally from satellite navigation system (SNS. At the time of this writing (January 2017 currently two global SNSs, GPS and GLONASS, are fully operational, two next, also global, Galileo and BeiDou are under construction. In each SNS the accuracy of the user’s position is affected by the three main factors: accuracy of each satellite position, accuracy of pseudorange measurement and satellite geometry. The user’s position error is a function of both the pseudorange error called UERE (User Equivalent Range Error and user/satellite geometry expressed by right Dilution Of Precision (DOP coefficient. This error is decomposed into two types of errors: the signal in space ranging error called URE (User Range Error and the user equipment error UEE. The detailed analyses of URE, UEE, UERE and DOP coefficients, and the changes of DOP coefficients in different days are presented in this paper.

  13. Translational and rotational intra- and inter-fractional errors in patient and target position during a short course of frameless stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Josipovic, Mirjana; Fredberg Persson, Gitte; Logadottir, Aashildur; Smulders, Bob; Westmann, Gunnar; Bangsgaard, Jens Peter

    2012-01-01

    Background. Implementation of cone beam computed tomography (CBCT) in frameless stereotactic body radiotherapy (SBRT) of lung tumours enables setup correction based on tumour position. The aim of this study was to compare setup accuracy with daily soft tissue matching to bony anatomy matching and evaluate intra- and inter-fractional translational and rotational errors in patient and target positions. Material and methods. Fifteen consecutive SBRT patients were included in the study. Vacuum cushions were used for immobilisation. SBRT plans were based on midventilation phase of four-dimensional (4D)-CT or three-dimensional (3D)-CT from PET/CT. Margins of 5 mm in the transversal plane and 10 mm in the cranio-caudal (CC) direction were applied. SBRT was delivered in three fractions within a week. At each fraction, CBCT was performed before and after the treatment. Setup accuracy comparison between soft tissue matching and bony anatomy matching was evaluated on pretreatment CBCTs. From differences in pre- and post-treatment CBCTs, we evaluated the extent of translational and rotational intra-fractional changes in patient position, tumour position and tumour baseline shift. All image registration was rigid with six degrees of freedom. Results. The median 3D difference between patient position based on bony anatomy matching and soft tissue matching was 3.0 mm (0-8.3 mm). The median 3D intra-fractional change in patient position was 1.4 mm (0-12.2 mm) and 2.2 mm (0-13.2 mm) in tumour position. The median 3D intra-fractional baseline shift was 2.2 mm (0-4.7 mm). With correction of translational errors, the remaining systematic and random errors were approximately 1deg. Conclusion. Soft tissue tumour matching improved precision of treatment delivery in frameless SBRT of lung tumours compared to image guidance using bone matching. The intra-fractional displacement of the target position was affected by both translational and rotational changes in tumour baseline position

  14. Laboratory errors and patient safety.

    Science.gov (United States)

    Miligy, Dawlat A

    2015-01-01

    Laboratory data are extensively used in medical practice; consequently, laboratory errors have a tremendous impact on patient safety. Therefore, programs designed to identify and reduce laboratory errors, as well as, setting specific strategies are required to minimize these errors and improve patient safety. The purpose of this paper is to identify part of the commonly encountered laboratory errors throughout our practice in laboratory work, their hazards on patient health care and some measures and recommendations to minimize or to eliminate these errors. Recording the encountered laboratory errors during May 2008 and their statistical evaluation (using simple percent distribution) have been done in the department of laboratory of one of the private hospitals in Egypt. Errors have been classified according to the laboratory phases and according to their implication on patient health. Data obtained out of 1,600 testing procedure revealed that the total number of encountered errors is 14 tests (0.87 percent of total testing procedures). Most of the encountered errors lay in the pre- and post-analytic phases of testing cycle (representing 35.7 and 50 percent, respectively, of total errors). While the number of test errors encountered in the analytic phase represented only 14.3 percent of total errors. About 85.7 percent of total errors were of non-significant implication on patients health being detected before test reports have been submitted to the patients. On the other hand, the number of test errors that have been already submitted to patients and reach the physician represented 14.3 percent of total errors. Only 7.1 percent of the errors could have an impact on patient diagnosis. The findings of this study were concomitant with those published from the USA and other countries. This proves that laboratory problems are universal and need general standardization and bench marking measures. Original being the first data published from Arabic countries that

  15. SU-E-T-261: Development of An Automated System to Detect Patient Identification and Positioning Errors Prior to Radiotherapy Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Jani, S; Low, D; Lamb, J [UCLA, Los Angeles, CA (United States)

    2015-06-15

    Purpose: To develop a system that can automatically detect patient identification and positioning errors using 3D computed tomography (CT) setup images and kilovoltage CT (kVCT) planning images. Methods: Planning kVCT images were collected for head-and-neck (H&N), pelvis, and spine treatments with corresponding 3D cone-beam CT (CBCT) and megavoltage CT (MVCT) setup images from TrueBeam and TomoTherapy units, respectively. Patient identification errors were simulated by registering setup and planning images from different patients. Positioning errors were simulated by misaligning the setup image by 1cm to 5cm in the six anatomical directions for H&N and pelvis patients. Misalignments for spine treatments were simulated by registering the setup image to adjacent vertebral bodies on the planning kVCT. A body contour of the setup image was used as an initial mask for image comparison. Images were pre-processed by image filtering and air voxel thresholding, and image pairs were assessed using commonly-used image similarity metrics as well as custom -designed metrics. A linear discriminant analysis classifier was trained and tested on the datasets, and misclassification error (MCE), sensitivity, and specificity estimates were generated using 10-fold cross validation. Results: Our workflow produced MCE estimates of 0.7%, 1.7%, and 0% for H&N, pelvis, and spine TomoTherapy images, respectively. Sensitivities and specificities ranged from 98.0% to 100%. MCEs of 3.5%, 2.3%, and 2.1% were obtained for TrueBeam images of the above sites, respectively, with sensitivity and specificity estimates between 96.2% and 98.4%. MCEs for 1cm H&N/pelvis misalignments were 1.3/5.1% and 9.1/8.6% for TomoTherapy and TrueBeam images, respectively. 2cm MCE estimates were 0.4%/1.6% and 3.1/3.2%, respectively. Vertebral misalignment MCEs were 4.8% and 4.9% for TomoTherapy and TrueBeam images, respectively. Conclusion: Patient identification and gross misalignment errors can be robustly and

  16. SU-E-T-261: Development of An Automated System to Detect Patient Identification and Positioning Errors Prior to Radiotherapy Treatment

    International Nuclear Information System (INIS)

    Jani, S; Low, D; Lamb, J

    2015-01-01

    Purpose: To develop a system that can automatically detect patient identification and positioning errors using 3D computed tomography (CT) setup images and kilovoltage CT (kVCT) planning images. Methods: Planning kVCT images were collected for head-and-neck (H&N), pelvis, and spine treatments with corresponding 3D cone-beam CT (CBCT) and megavoltage CT (MVCT) setup images from TrueBeam and TomoTherapy units, respectively. Patient identification errors were simulated by registering setup and planning images from different patients. Positioning errors were simulated by misaligning the setup image by 1cm to 5cm in the six anatomical directions for H&N and pelvis patients. Misalignments for spine treatments were simulated by registering the setup image to adjacent vertebral bodies on the planning kVCT. A body contour of the setup image was used as an initial mask for image comparison. Images were pre-processed by image filtering and air voxel thresholding, and image pairs were assessed using commonly-used image similarity metrics as well as custom -designed metrics. A linear discriminant analysis classifier was trained and tested on the datasets, and misclassification error (MCE), sensitivity, and specificity estimates were generated using 10-fold cross validation. Results: Our workflow produced MCE estimates of 0.7%, 1.7%, and 0% for H&N, pelvis, and spine TomoTherapy images, respectively. Sensitivities and specificities ranged from 98.0% to 100%. MCEs of 3.5%, 2.3%, and 2.1% were obtained for TrueBeam images of the above sites, respectively, with sensitivity and specificity estimates between 96.2% and 98.4%. MCEs for 1cm H&N/pelvis misalignments were 1.3/5.1% and 9.1/8.6% for TomoTherapy and TrueBeam images, respectively. 2cm MCE estimates were 0.4%/1.6% and 3.1/3.2%, respectively. Vertebral misalignment MCEs were 4.8% and 4.9% for TomoTherapy and TrueBeam images, respectively. Conclusion: Patient identification and gross misalignment errors can be robustly and

  17. Error Analysis of Determining Airplane Location by Global Positioning System

    OpenAIRE

    Hajiyev, Chingiz; Burat, Alper

    1999-01-01

    This paper studies the error analysis of determining airplane location by global positioning system (GPS) using statistical testing method. The Newton Rhapson method positions the airplane at the intersection point of four spheres. Absolute errors, relative errors and standard deviation have been calculated The results show that the positioning error of the airplane varies with the coordinates of GPS satellite and the airplane.

  18. A methodology for translating positional error into measures of attribute error, and combining the two error sources

    Science.gov (United States)

    Yohay Carmel; Curtis Flather; Denis Dean

    2006-01-01

    This paper summarizes our efforts to investigate the nature, behavior, and implications of positional error and attribute error in spatiotemporal datasets. Estimating the combined influence of these errors on map analysis has been hindered by the fact that these two error types are traditionally expressed in different units (distance units, and categorical units,...

  19. Common positioning errors in panoramic radiography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Randon, Rafael Henrique Nunes [Stomathology and Oral Diagnostic Program, School of Dentistry of Sao Paulo, University of Sao Paulo, Sao Paulo (Brazil); Pereira, Yamba Carla Lara [Biology Dental Buco Graduate Program, School of Dentistry of Piracicaba, University of Campinas, Piracicaba (Brazil); Nascimento, Glauce Crivelaro do [Psychobiology Graduate Program, School of Philosophy, Science and Literature of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto (Brazil)

    2014-03-15

    Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

  20. Common positioning errors in panoramic radiography: A review

    International Nuclear Information System (INIS)

    Randon, Rafael Henrique Nunes; Pereira, Yamba Carla Lara; Nascimento, Glauce Crivelaro do

    2014-01-01

    Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

  1. Influence of Ephemeris Error on GPS Single Point Positioning Accuracy

    Science.gov (United States)

    Lihua, Ma; Wang, Meng

    2013-09-01

    The Global Positioning System (GPS) user makes use of the navigation message transmitted from GPS satellites to achieve its location. Because the receiver uses the satellite's location in position calculations, an ephemeris error, a difference between the expected and actual orbital position of a GPS satellite, reduces user accuracy. The influence extent is decided by the precision of broadcast ephemeris from the control station upload. Simulation analysis with the Yuma almanac show that maximum positioning error exists in the case where the ephemeris error is along the line-of-sight (LOS) direction. Meanwhile, the error is dependent on the relationship between the observer and spatial constellation at some time period.

  2. Approaches to relativistic positioning around Earth and error estimations

    Science.gov (United States)

    Puchades, Neus; Sáez, Diego

    2016-01-01

    In the context of relativistic positioning, the coordinates of a given user may be calculated by using suitable information broadcast by a 4-tuple of satellites. Our 4-tuples belong to the Galileo constellation. Recently, we estimated the positioning errors due to uncertainties in the satellite world lines (U-errors). A distribution of U-errors was obtained, at various times, in a set of points covering a large region surrounding Earth. Here, the positioning errors associated to the simplifying assumption that photons move in Minkowski space-time (S-errors) are estimated and compared with the U-errors. Both errors have been calculated for the same points and times to make comparisons possible. For a certain realistic modeling of the world line uncertainties, the estimated S-errors have proved to be smaller than the U-errors, which shows that the approach based on the assumption that the Earth's gravitational field produces negligible effects on photons may be used in a large region surrounding Earth. The applicability of this approach - which simplifies numerical calculations - to positioning problems, and the usefulness of our S-error maps, are pointed out. A better approach, based on the assumption that photons move in the Schwarzschild space-time governed by an idealized Earth, is also analyzed. More accurate descriptions of photon propagation involving non symmetric space-time structures are not necessary for ordinary positioning and spacecraft navigation around Earth.

  3. Common Positioning Errors in Digital Panoramic Radiographies Taken In Mashhad Dental School

    Directory of Open Access Journals (Sweden)

    Ali Bagherpour

    2018-06-01

    Full Text Available Introduction: The present study was aimed at evaluating common positioning errors on panoramic radiographs taken in the Radiology Department of Mashhad Dental School. Materials and methods: The study sample included 1,990 digital panoramic radiographs taken in the Radiology Department of Mashhad Dental School by a Planmeca Promax (Planmeca Oy, Helsinki, Finland, during a 2-year period (2010–2012. All radiographs, according to dentition and sex, were evaluated for positioning errors. Results: There were 1,927 (96.8% panoramic radiographs with one or more errors. While the number of errors in each image varied between one and five, most images had one error (48.4%. The most common error was that the tongue was not in contact with the hard palate (94.8%. "Open lips" was an error not seen in any patients. Conclusions:positioning errors are common in panoramic radiographies. The most common error observed in this study was a failure to place the tongue on the palate. This error and the other errors reported in this study can be reduced by training the technicians and spending little more time for patient positioning and more effective communication with the patients.

  4. Aliasing errors in measurements of beam position and ellipticity

    International Nuclear Information System (INIS)

    Ekdahl, Carl

    2005-01-01

    Beam position monitors (BPMs) are used in accelerators and ion experiments to measure currents, position, and azimuthal asymmetry. These usually consist of discrete arrays of electromagnetic field detectors, with detectors located at several equally spaced azimuthal positions at the beam tube wall. The discrete nature of these arrays introduces systematic errors into the data, independent of uncertainties resulting from signal noise, lack of recording dynamic range, etc. Computer simulations were used to understand and quantify these aliasing errors. If required, aliasing errors can be significantly reduced by employing more than the usual four detectors in the BPMs. These simulations show that the error in measurements of the centroid position of a large beam is indistinguishable from the error in the position of a filament. The simulations also show that aliasing errors in the measurement of beam ellipticity are very large unless the beam is accurately centered. The simulations were used to quantify the aliasing errors in beam parameter measurements during early experiments on the DARHT-II accelerator, demonstrating that they affected the measurements only slightly, if at all

  5. Aliasing errors in measurements of beam position and ellipticity

    Science.gov (United States)

    Ekdahl, Carl

    2005-09-01

    Beam position monitors (BPMs) are used in accelerators and ion experiments to measure currents, position, and azimuthal asymmetry. These usually consist of discrete arrays of electromagnetic field detectors, with detectors located at several equally spaced azimuthal positions at the beam tube wall. The discrete nature of these arrays introduces systematic errors into the data, independent of uncertainties resulting from signal noise, lack of recording dynamic range, etc. Computer simulations were used to understand and quantify these aliasing errors. If required, aliasing errors can be significantly reduced by employing more than the usual four detectors in the BPMs. These simulations show that the error in measurements of the centroid position of a large beam is indistinguishable from the error in the position of a filament. The simulations also show that aliasing errors in the measurement of beam ellipticity are very large unless the beam is accurately centered. The simulations were used to quantify the aliasing errors in beam parameter measurements during early experiments on the DARHT-II accelerator, demonstrating that they affected the measurements only slightly, if at all.

  6. The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT

    International Nuclear Information System (INIS)

    Kim, Jung-in; Park, So-Yeon; Kim, Hak Jae; Kim, Jin Ho; Ye, Sung-Joon; Park, Jong Min

    2014-01-01

    To investigate the sensitivity of various gamma criteria used in the gamma-index method for patient-specific volumetric modulated arc therapy (VMAT) quality assurance (QA) for stereotactic body radiation therapy (SBRT) using a flattening filter free (FFF) photon beam. Three types of intentional misalignments were introduced to original high-definition multi-leaf collimator (HD-MLC) plans. The first type, referred to Class Out, involved the opening of each bank of leaves. The second type, Class In, involved the closing of each bank of leaves. The third type, Class Shift, involved the shifting of each bank of leaves towards the ground. Patient-specific QAs for the original and the modified plans were performed with MapCHECK2 and EBT2 films. The sensitivity of the gamma-index method using criteria of 1%/1 mm, 1.5%/1.5 mm, 1%/2 mm, 2%/1 mm and 2%/2 mm was investigated with absolute passing rates according to the magnitudes of MLCs misalignments. In addition, the changes in dose-volumetric indicators due to the magnitudes of MLC misalignments were investigated. The correlations between passing rates and the changes in dose-volumetric indicators were also investigated using Spearman’s rank correlation coefficient (γ). The criterion of 2%/1 mm was able to detect Class Out and Class In MLC misalignments of 0.5 mm and Class Shift misalignments of 1 mm. The widely adopted clinical criterion of 2%/2 mm was not able to detect 0.5 mm MLC errors of the Class Out or Class In types, and also unable to detect 3 mm Class Shift errors. No correlations were observed between dose-volumetric changes and gamma passing rates (γ < 0.8). Gamma criterion of 2%/1 mm was found to be suitable as a tolerance level with passing rates of 90% and 80% for patient-specific VMAT QA for SBRT when using MapCHECK2 and EBT2 film, respectively

  7. Positional error in automated geocoding of residential addresses

    Directory of Open Access Journals (Sweden)

    Talbot Thomas O

    2003-12-01

    Full Text Available Abstract Background Public health applications using geographic information system (GIS technology are steadily increasing. Many of these rely on the ability to locate where people live with respect to areas of exposure from environmental contaminants. Automated geocoding is a method used to assign geographic coordinates to an individual based on their street address. This method often relies on street centerline files as a geographic reference. Such a process introduces positional error in the geocoded point. Our study evaluated the positional error caused during automated geocoding of residential addresses and how this error varies between population densities. We also evaluated an alternative method of geocoding using residential property parcel data. Results Positional error was determined for 3,000 residential addresses using the distance between each geocoded point and its true location as determined with aerial imagery. Error was found to increase as population density decreased. In rural areas of an upstate New York study area, 95 percent of the addresses geocoded to within 2,872 m of their true location. Suburban areas revealed less error where 95 percent of the addresses geocoded to within 421 m. Urban areas demonstrated the least error where 95 percent of the addresses geocoded to within 152 m of their true location. As an alternative to using street centerline files for geocoding, we used residential property parcel points to locate the addresses. In the rural areas, 95 percent of the parcel points were within 195 m of the true location. In suburban areas, this distance was 39 m while in urban areas 95 percent of the parcel points were within 21 m of the true location. Conclusion Researchers need to determine if the level of error caused by a chosen method of geocoding may affect the results of their project. As an alternative method, property data can be used for geocoding addresses if the error caused by traditional methods is

  8. Perceptual learning eases crowding by reducing recognition errors but not position errors.

    Science.gov (United States)

    Xiong, Ying-Zi; Yu, Cong; Zhang, Jun-Yun

    2015-08-01

    When an observer reports a letter flanked by additional letters in the visual periphery, the response errors (the crowding effect) may result from failure to recognize the target letter (recognition errors), from mislocating a correctly recognized target letter at a flanker location (target misplacement errors), or from reporting a flanker as the target letter (flanker substitution errors). Crowding can be reduced through perceptual learning. However, it is not known how perceptual learning operates to reduce crowding. In this study we trained observers with a partial-report task (Experiment 1), in which they reported the central target letter of a three-letter string presented in the visual periphery, or a whole-report task (Experiment 2), in which they reported all three letters in order. We then assessed the impact of training on recognition of both unflanked and flanked targets, with particular attention to how perceptual learning affected the types of errors. Our results show that training improved target recognition but not single-letter recognition, indicating that training indeed affected crowding. However, training did not reduce target misplacement errors or flanker substitution errors. This dissociation between target recognition and flanker substitution errors supports the view that flanker substitution may be more likely a by-product (due to response bias), rather than a cause, of crowding. Moreover, the dissociation is not consistent with hypothesized mechanisms of crowding that would predict reduced positional errors.

  9. Force Reproduction Error Depends on Force Level, whereas the Position Reproduction Error Does Not

    NARCIS (Netherlands)

    Onneweer, B.; Mugge, W.; Schouten, Alfred Christiaan

    2016-01-01

    When reproducing a previously perceived force or position humans make systematic errors. This study determined the effect of force level on force and position reproduction, when both target and reproduction force are self-generated with the same hand. Subjects performed force reproduction tasks at

  10. Predicting positional error of MLC using volumetric analysis

    International Nuclear Information System (INIS)

    Hareram, E.S.

    2008-01-01

    IMRT normally using multiple beamlets (small width of the beam) for a particular field to deliver so that it is imperative to maintain the positional accuracy of the MLC in order to deliver integrated computed dose accurately. Different manufacturers have reported high precession on MLC devices with leaf positional accuracy nearing 0.1 mm but measuring and rectifying the error in this accuracy is very difficult. Various methods are used to check MLC position and among this volumetric analysis is one of the technique. Volumetric approach was adapted in our method using primus machine and 0.6cc chamber at 5 cm depth In perspex. MLC of 1 mm error introduces an error of 20%, more sensitive to other methods

  11. SU-G-JeP3-02: Comparison of Magnitude and Frequency of Patient Positioning Errors in Breast Irradiation Using AlignRT 3D Optical Surface Imaging and Skin Mark Techniques

    International Nuclear Information System (INIS)

    Yao, R; Chisela, W; Dorbu, G

    2016-01-01

    Purpose: To evaluate clinical usefulness of AlignRT (Vision RT Ltd., London, UK) in reducing patient positioning errors in breast irradiation. Methods: 60 patients undergoing whole breast irradiation were selected for this study. Patients were treated to the left or right breast lying on Qfix Access breast board (Qfix, Avondale, PA) in supine position for 28 fractions using tangential fields. 30 patients were aligned using AlignRT by aligning a breast surface region of interest (ROI) to the same area from a reference surface image extracted from planning CT. When the patient’s surface image deviated from the reference by more than 3mm on one or more translational and rotational directions, a new reference was acquired using AlignRT in-room cameras. The other 30 patients were aligned to the skin marks with room lasers. On-Board MV portal images of medial field were taken daily and matched to the DRRs. The magnitude and frequency of positioning errors were determined from measured translational shifts. Kolmogorov-Smirnov test was used to evaluate statistical differences of positional accuracy and precision between AlignRT and non-AlignRT patients. Results: The percentage of port images with no shift required was 46.5% and 27.0% in vertical, 49.8% and 25.8% in longitudinal, 47.6% and 28.5% in lateral for AlignRT and non-AlignRT patients, respectively. The percentage of port images requiring more than 3mm shifts was 18.1% and 35.1% in vertical, 28.6% and 50.8% in longitudinal, 11.3% and 24.2% in lateral for AlignRT and non-AlignRT patients, respectively. Kolmogorov-Smirnov test showed that there were significant differences between the frequency distributions of AlignRT and non-AlignRT in vertical, longitudinal, and lateral shifts. Conclusion: As confirmed by port images, AlignRT-assisted patient positioning can significantly reduce the frequency and magnitude of patient setup errors in breast irradiation compared to the use of lasers and skin marks.

  12. The error model and experiment of measuring angular position error based on laser collimation

    Science.gov (United States)

    Cai, Yangyang; Yang, Jing; Li, Jiakun; Feng, Qibo

    2018-01-01

    Rotary axis is the reference component of rotation motion. Angular position error is the most critical factor which impair the machining precision among the six degree-of-freedom (DOF) geometric errors of rotary axis. In this paper, the measuring method of angular position error of rotary axis based on laser collimation is thoroughly researched, the error model is established and 360 ° full range measurement is realized by using the high precision servo turntable. The change of space attitude of each moving part is described accurately by the 3×3 transformation matrices and the influences of various factors on the measurement results is analyzed in detail. Experiments results show that the measurement method can achieve high measurement accuracy and large measurement range.

  13. Source position error influence on industry CT image quality

    International Nuclear Information System (INIS)

    Cong Peng; Li Zhipeng; Wu Haifeng

    2004-01-01

    Based on the emulational exercise, the influence of source position error on industry CT (ICT) image quality was studied and the valuable parameters were obtained for the design of ICT. The vivid container CT image was also acquired from the CT testing system. (authors)

  14. Positioning devices for patients

    International Nuclear Information System (INIS)

    Heavens, M.

    1981-01-01

    It has been suggested that it is very important to position patients reproducibly at different stages of radiotherapy treatment planning and treatment, or similar procedures. Devices have been described for positioning a patient's upper and lower thorax. This invention provides reproducible positioning for a female patient's breasts, for example in planning treatment of and treating breast tumours. The patient is placed prone, using for example an upper thorax device. A support device is placed central to and beneath her breasts to partially displace them outwards. The device may be triangular in section with one apex contacting the chest wall at the sternum. Restraining straps may be provided to hold the breasts against the support device. Means may be provided to take a healthy breast from the path of radiation through the tumour. (author)

  15. Medication errors: the role of the patient.

    Science.gov (United States)

    Britten, Nicky

    2009-06-01

    1. Patients and their carers will usually be the first to notice any observable problems resulting from medication errors. They will probably be unable to distinguish between medication errors, adverse drug reactions, or 'side effects'. 2. Little is known about how patients understand drug related problems or how they make attributions of adverse effects. Some research suggests that patients' cognitive models of adverse drug reactions bear a close relationship to models of illness perception. 3. Attributions of adverse drug reactions are related to people's previous experiences and to their level of education. The evidence suggests that on the whole patients' reports of adverse drug reactions are accurate. However, patients do not report all the problems they perceive and are more likely to report those that they do perceive as severe. Patients may not report problems attributed to their medications if they are fearful of doctors' reactions. Doctors may respond inappropriately to patients' concerns, for example by ignoring them. Some authors have proposed the use of a symptom checklist to elicit patients' reports of suspected adverse drug reactions. 4. Many patients want information about adverse drug effects, and the challenge for the professional is to judge how much information to provide and the best way of doing so. Professionals' inappropriate emphasis on adherence may be dangerous when a medication error has occurred. 5. Recent NICE guidelines recommend that professionals should ask patients if they have any concerns about their medicines, and this approach is likely to yield information conducive to the identification of medication errors.

  16. Analysis of positioning errors in radiotherapy; Analyse des erreurs de positionnement en radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Josset-Gaudaire, S.; Lisbona, A.; Llagostera, C.; Delpon, G.; Chiavassa, S.; Brunet, G. [Service de physique medicale, ICO Rene-Gauducheau, Saint Herblain (France); Rousset, S.; Nerriere, E.; Leblanc, M. [Service de radiotherapie, ICO Rene-Gauducheau, Saint Herblain (France)

    2011-10-15

    Within the frame of a study of control imagery management in radiotherapy, the authors report the study of positioning errors associated with control imagery in order to give an overview of practice and to help the adjustment or definition of action levels for clinical practice. Twenty groups of patients have been defined by considering tumour locations (head, ENT, thorax, breast, abdomen, and pelvis), treatment positions, immobilization systems and imagery systems. Positioning errors have thus been analyzed for 340 patients. Aspects and practice to be improved are identified. Short communication

  17. Translational and rotational intra- and inter-fractional errors in patient and target position during a short course of frameless stereotactic body radiotherapy

    DEFF Research Database (Denmark)

    Josipovic, Mirjana; Persson, Gitte Fredberg; Logadottir, Ashildur

    2012-01-01

    Implementation of cone beam computed tomography (CBCT) in frameless stereotactic body radiotherapy (SBRT) of lung tumours enables setup correction based on tumour position. The aim of this study was to compare setup accuracy with daily soft tissue matching to bony anatomy matching and evaluate...

  18. Slide-position errors degrade machined optical component quality

    International Nuclear Information System (INIS)

    Arnold, J.B.; Steger, P.J.; Burleson, R.R.

    1975-01-01

    An ultraprecision lathe is being developed at the Oak Ridge Y-12 Plant to fabricate optical components for use in high-energy laser systems. The lathe has the capability to produce virtually any shape mirror which is symmetrical about an axis of revolution. Two basic types of mirrors are fabricated on the lathe, namely: (1) mirrors which are machined using a single slide motion (such as flats and cylinders), and (2) mirrors which are produced by two-coordinated slide motions (such as hyperbolic reflectors; large, true-radius reflectors, and other contoured-surface reflectors). The surface-finish quality of typical mirrors machined by a single axis of motion is better than 13 nm, peak to valley, which is an order of magnitude better than the surface finishes of mirrors produced by two axes of motion. Surface finish refers to short-wavelength-figure errors that are visibly detectable. The primary cause of the inability to produce significantly better surface finishes on contoured mirrors has been determined as positional errors which exist in the slide positioning systems. The correction of these errors must be accomplished before contoured surface finishes comparable to the flat and cylinder can be machined on the lathe

  19. Coordinated joint motion control system with position error correction

    Science.gov (United States)

    Danko, George L.

    2016-04-05

    Disclosed are an articulated hydraulic machine supporting, control system and control method for same. The articulated hydraulic machine has an end effector for performing useful work. The control system is capable of controlling the end effector for automated movement along a preselected trajectory. The control system has a position error correction system to correct discrepancies between an actual end effector trajectory and a desired end effector trajectory. The correction system can employ one or more absolute position signals provided by one or more acceleration sensors supported by one or more movable machine elements. Good trajectory positioning and repeatability can be obtained. A two joystick controller system is enabled, which can in some cases facilitate the operator's task and enhance their work quality and productivity.

  20. Nonlinear control of ships minimizing the position tracking errors

    Directory of Open Access Journals (Sweden)

    Svein P. Berge

    1999-07-01

    Full Text Available In this paper, a nonlinear tracking controller with integral action for ships is presented. The controller is based on state feedback linearization. Exponential convergence of the vessel-fixed position and velocity errors are proven by using Lyapunov stability theory. Since we only have two control devices, a rudder and a propeller, we choose to control the longship and the sideship position errors to zero while the heading is stabilized indirectly. A Virtual Reference Point (VRP is defined at the bow or ahead of the ship. The VRP is used for tracking control. It is shown that the distance from the center of rotation to the VRP will influence on the stability of the zero dynamics. By selecting the VRP at the bow or even ahead of the bow, the damping in yaw can be increased and the zero dynamics is stabilized. Hence, the heading angle will be less sensitive to wind, currents and waves. The control law is simulated by using a nonlinear model of the Japanese training ship Shiojimaru with excellent results. Wind forces are added to demonstrate the robustness and performance of the integral controller.

  1. Sensorless SPMSM Position Estimation Using Position Estimation Error Suppression Control and EKF in Wide Speed Range

    Directory of Open Access Journals (Sweden)

    Zhanshan Wang

    2014-01-01

    Full Text Available The control of a high performance alternative current (AC motor drive under sensorless operation needs the accurate estimation of rotor position. In this paper, one method of accurately estimating rotor position by using both motor complex number model based position estimation and position estimation error suppression proportion integral (PI controller is proposed for the sensorless control of the surface permanent magnet synchronous motor (SPMSM. In order to guarantee the accuracy of rotor position estimation in the flux-weakening region, one scheme of identifying the permanent magnet flux of SPMSM by extended Kalman filter (EKF is also proposed, which formed the effective combination method to realize the sensorless control of SPMSM with high accuracy. The simulation results demonstrated the validity and feasibility of the proposed position/speed estimation system.

  2. Propagation of positional error in 3D GIS

    NARCIS (Netherlands)

    Biljecki, Filip; Heuvelink, Gerard B.M.; Ledoux, Hugo; Stoter, Jantien

    2015-01-01

    While error propagation in GIS is a topic that has received a lot of attention, it has not been researched with 3D GIS data. We extend error propagation to 3D city models using a Monte Carlo simulation on a use case of annual solar irradiation estimation of building rooftops for assessing the

  3. Mitigating Errors in External Respiratory Surrogate-Based Models of Tumor Position

    International Nuclear Information System (INIS)

    Malinowski, Kathleen T.; McAvoy, Thomas J.; George, Rohini; Dieterich, Sonja; D'Souza, Warren D.

    2012-01-01

    Purpose: To investigate the effect of tumor site, measurement precision, tumor–surrogate correlation, training data selection, model design, and interpatient and interfraction variations on the accuracy of external marker-based models of tumor position. Methods and Materials: Cyberknife Synchrony system log files comprising synchronously acquired positions of external markers and the tumor from 167 treatment fractions were analyzed. The accuracy of Synchrony, ordinary-least-squares regression, and partial-least-squares regression models for predicting the tumor position from the external markers was evaluated. The quantity and timing of the data used to build the predictive model were varied. The effects of tumor–surrogate correlation and the precision in both the tumor and the external surrogate position measurements were explored by adding noise to the data. Results: The tumor position prediction errors increased during the duration of a fraction. Increasing the training data quantities did not always lead to more accurate models. Adding uncorrelated noise to the external marker-based inputs degraded the tumor–surrogate correlation models by 16% for partial-least-squares and 57% for ordinary-least-squares. External marker and tumor position measurement errors led to tumor position prediction changes 0.3–3.6 times the magnitude of the measurement errors, varying widely with model algorithm. The tumor position prediction errors were significantly associated with the patient index but not with the fraction index or tumor site. Partial-least-squares was as accurate as Synchrony and more accurate than ordinary-least-squares. Conclusions: The accuracy of surrogate-based inferential models of tumor position was affected by all the investigated factors, except for the tumor site and fraction index.

  4. Mitigating Errors in External Respiratory Surrogate-Based Models of Tumor Position

    Energy Technology Data Exchange (ETDEWEB)

    Malinowski, Kathleen T. [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States); Fischell Department of Bioengineering, University of Maryland, College Park, MD (United States); McAvoy, Thomas J. [Fischell Department of Bioengineering, University of Maryland, College Park, MD (United States); Department of Chemical and Biomolecular Engineering and Institute of Systems Research, University of Maryland, College Park, MD (United States); George, Rohini [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States); Dieterich, Sonja [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); D' Souza, Warren D., E-mail: wdsou001@umaryland.edu [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States); Fischell Department of Bioengineering, University of Maryland, College Park, MD (United States)

    2012-04-01

    Purpose: To investigate the effect of tumor site, measurement precision, tumor-surrogate correlation, training data selection, model design, and interpatient and interfraction variations on the accuracy of external marker-based models of tumor position. Methods and Materials: Cyberknife Synchrony system log files comprising synchronously acquired positions of external markers and the tumor from 167 treatment fractions were analyzed. The accuracy of Synchrony, ordinary-least-squares regression, and partial-least-squares regression models for predicting the tumor position from the external markers was evaluated. The quantity and timing of the data used to build the predictive model were varied. The effects of tumor-surrogate correlation and the precision in both the tumor and the external surrogate position measurements were explored by adding noise to the data. Results: The tumor position prediction errors increased during the duration of a fraction. Increasing the training data quantities did not always lead to more accurate models. Adding uncorrelated noise to the external marker-based inputs degraded the tumor-surrogate correlation models by 16% for partial-least-squares and 57% for ordinary-least-squares. External marker and tumor position measurement errors led to tumor position prediction changes 0.3-3.6 times the magnitude of the measurement errors, varying widely with model algorithm. The tumor position prediction errors were significantly associated with the patient index but not with the fraction index or tumor site. Partial-least-squares was as accurate as Synchrony and more accurate than ordinary-least-squares. Conclusions: The accuracy of surrogate-based inferential models of tumor position was affected by all the investigated factors, except for the tumor site and fraction index.

  5. Determination of global positioning system (GPS) receiver clock errors: impact on positioning accuracy

    International Nuclear Information System (INIS)

    Yeh, Ta-Kang; Hwang, Cheinway; Xu, Guochang; Wang, Chuan-Sheng; Lee, Chien-Chih

    2009-01-01

    Enhancing the positioning precision is the primary pursuit of global positioning system (GPS) users. To achieve this goal, most studies have focused on the relationship between GPS receiver clock errors and GPS positioning precision. This study utilizes undifferentiated phase data to calculate GPS clock errors and to compare with the frequency of cesium clock directly, to verify estimated clock errors by the method used in this paper. The frequency stability calculated from this paper (the indirect method) and measured from the National Standard Time and Frequency Laboratory (NSTFL) of Taiwan (the direct method) match to 1.5 × 10 −12 (the value from this study was smaller than that from NSTFL), suggesting that the proposed technique has reached a certain level of quality. The built-in quartz clocks in the GPS receivers yield relative frequency offsets that are 3–4 orders higher than those of rubidium clocks. The frequency stability of the quartz clocks is on average two orders worse than that of the rubidium clock. Using the rubidium clock instead of the quartz clock, the horizontal and vertical positioning accuracies were improved by 26–78% (0.6–3.6 mm) and 20–34% (1.3–3.0 mm), respectively, for a short baseline. These improvements are 7–25% (0.3–1.7 mm) and 11% (1.7 mm) for a long baseline. Our experiments show that the frequency stability of the clock, rather than relative frequency offset, is the governing factor of positioning accuracy

  6. Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number

    International Nuclear Information System (INIS)

    Zygmanski, Piotr; Kung, Jong H.; Jiang, Steve B.; Chin, Lee

    2003-01-01

    In d-MLC based IMRT, leaves move along a trajectory that lies within a user-defined tolerance (TOL) about the ideal trajectory specified in a d-MLC sequence file. The MLC controller measures leaf positions multiple times per second and corrects them if they deviate from ideal positions by a value greater than TOL. The magnitude of leaf-positional errors resulting from finite mechanical precision depends on the performance of the MLC motors executing leaf motions and is generally larger if leaves are forced to move at higher speeds. The maximum value of leaf-positional errors can be limited by decreasing TOL. However, due to the inherent time delay in the MLC controller, this may not happen at all times. Furthermore, decreasing the leaf tolerance results in a larger number of beam hold-offs, which, in turn leads, to a longer delivery time and, paradoxically, to higher chances of leaf-positional errors (≤TOL). On the other end, the magnitude of leaf-positional errors depends on the complexity of the fluence map to be delivered. Recently, it has been shown that it is possible to determine the actual distribution of leaf-positional errors either by the imaging of moving MLC apertures with a digital imager or by analysis of a MLC log file saved by a MLC controller. This leads next to an important question: What is the relation between the distribution of leaf-positional errors and fluence errors. In this work, we introduce an analytical method to determine this relation in dynamic IMRT delivery. We model MLC errors as Random-Leaf Positional (RLP) errors described by a truncated normal distribution defined by two characteristic parameters: a standard deviation σ and a cut-off value Δx 0 (Δx 0 ∼TOL). We quantify fluence errors for two cases: (i) Δx 0 >>σ (unrestricted normal distribution) and (ii) Δx 0 0 --limited normal distribution). We show that an average fluence error of an IMRT field is proportional to (i) σ/ALPO and (ii) Δx 0 /ALPO, respectively, where

  7. Putting a face on medical errors: a patient perspective.

    Science.gov (United States)

    Kooienga, Sarah; Stewart, Valerie T

    2011-01-01

    Knowledge of the patient's perspective on medical error is limited. Research efforts have centered on how best to disclose error and how patients desire to have medical error disclosed. On the basis of a qualitative descriptive component of a mixed method study, a purposive sample of 30 community members told their stories of medical error. Their experiences focused on lack of communication, missed communication, or provider's poor interpersonal style of communication, greatly contrasting with the formal definition of error as failure to follow a set standard of care. For these participants, being a patient was more important than error or how an error is disclosed. The patient's understanding of error must be a key aspect of any quality improvement strategy. © 2010 National Association for Healthcare Quality.

  8. Impact of MLC leaf position errors on simple and complex IMRT plans for head and neck cancer

    International Nuclear Information System (INIS)

    Mu, G; Ludlum, E; Xia, P

    2008-01-01

    The dosimetric impact of random and systematic multi-leaf collimator (MLC) leaf position errors is relatively unknown for head and neck intensity-modulated radiotherapy (IMRT) patients. In this report we studied 17 head and neck IMRT patients, including 12 treated with simple plans ( 100 segments). Random errors (-2 to +2 mm) and systematic errors (±0.5 mm and ±1 mm) in MLC leaf positions were introduced into the clinical plans and the resultant dose distributions were analyzed based on defined endpoint doses. The dosimetric effect was insignificant for random MLC leaf position errors up to 2 mm for both simple and complex plans. However, for systematic MLC leaf position errors, we found significant dosimetric differences between the simple and complex IMRT plans. For 1 mm systematic error, the average changes in D 95% were 4% in simple plans versus 8% in complex plans. The average changes in D 0.1cc of the spinal cord and brain stem were 4% in simple plans versus 12% in complex plans. The average changes in parotid glands were 9% in simple plans versus 13% for the complex plans. Overall, simple IMRT plans are less sensitive to leaf position errors than complex IMRT plans

  9. A machine learning approach to the accurate prediction of multi-leaf collimator positional errors

    Science.gov (United States)

    Carlson, Joel N. K.; Park, Jong Min; Park, So-Yeon; In Park, Jong; Choi, Yunseok; Ye, Sung-Joon

    2016-03-01

    Discrepancies between planned and delivered movements of multi-leaf collimators (MLCs) are an important source of errors in dose distributions during radiotherapy. In this work we used machine learning techniques to train models to predict these discrepancies, assessed the accuracy of the model predictions, and examined the impact these errors have on quality assurance (QA) procedures and dosimetry. Predictive leaf motion parameters for the models were calculated from the plan files, such as leaf position and velocity, whether the leaf was moving towards or away from the isocenter of the MLC, and many others. Differences in positions between synchronized DICOM-RT planning files and DynaLog files reported during QA delivery were used as a target response for training of the models. The final model is capable of predicting MLC positions during delivery to a high degree of accuracy. For moving MLC leaves, predicted positions were shown to be significantly closer to delivered positions than were planned positions. By incorporating predicted positions into dose calculations in the TPS, increases were shown in gamma passing rates against measured dose distributions recorded during QA delivery. For instance, head and neck plans with 1%/2 mm gamma criteria had an average increase in passing rate of 4.17% (SD  =  1.54%). This indicates that the inclusion of predictions during dose calculation leads to a more realistic representation of plan delivery. To assess impact on the patient, dose volumetric histograms (DVH) using delivered positions were calculated for comparison with planned and predicted DVHs. In all cases, predicted dose volumetric parameters were in closer agreement to the delivered parameters than were the planned parameters, particularly for organs at risk on the periphery of the treatment area. By incorporating the predicted positions into the TPS, the treatment planner is given a more realistic view of the dose distribution as it will truly be

  10. Brain State Before Error Making in Young Patients With Mild Spastic Cerebral Palsy.

    Science.gov (United States)

    Hakkarainen, Elina; Pirilä, Silja; Kaartinen, Jukka; van der Meere, Jaap J

    2015-10-01

    In the present experiment, children with mild spastic cerebral palsy and a control group carried out a memory recognition task. The key question was if errors of the patient group are foreshadowed by attention lapses, by weak motor preparation, or by both. Reaction times together with event-related potentials associated with motor preparation (frontal late contingent negative variation), attention (parietal P300), and response evaluation (parietal error-preceding positivity) were investigated in instances where 3 subsequent correct trials preceded an error. The findings indicated that error responses of the patient group are foreshadowed by weak motor preparation in correct trials directly preceding an error. © The Author(s) 2015.

  11. SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

    Energy Technology Data Exchange (ETDEWEB)

    Ju, S; Hong, C; Kim, M; Chung, K; Kim, J; Han, Y; Ahn, S; Chung, S; Shin, E; Shin, J; Kim, H; Kim, D; Choi, D [Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed without the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.

  12. Effects of Target Positioning Error on Motion Compensation for Airborne Interferometric SAR

    Directory of Open Access Journals (Sweden)

    Li Yin-wei

    2013-12-01

    Full Text Available The measurement inaccuracies of Inertial Measurement Unit/Global Positioning System (IMU/GPS as well as the positioning error of the target may contribute to the residual uncompensated motion errors in the MOtion COmpensation (MOCO approach based on the measurement of IMU/GPS. Aiming at the effects of target positioning error on MOCO for airborne interferometric SAR, the paper firstly deduces a mathematical model of residual motion error bring out by target positioning error under the condition of squint. And the paper analyzes the effects on the residual motion error caused by system sampling delay error, the Doppler center frequency error and reference DEM error which result in target positioning error based on the model. Then, the paper discusses the effects of the reference DEM error on the interferometric SAR image quality, the interferometric phase and the coherent coefficient. The research provides theoretical bases for the MOCO precision in signal processing of airborne high precision SAR and airborne repeat-pass interferometric SAR.

  13. Medication errors : the impact of prescribing and transcribing errors on preventable harm in hospitalised patients

    NARCIS (Netherlands)

    van Doormaal, J.E.; van der Bemt, P.M.L.A.; Mol, P.G.M.; Egberts, A.C.G.; Haaijer-Ruskamp, F.M.; Kosterink, J.G.W.; Zaal, Rianne J.

    Background: Medication errors (MEs) affect patient safety to a significant extent. Because these errors can lead to preventable adverse drug events (pADEs), it is important to know what type of ME is the most prevalent cause of these pADEs. This study determined the impact of the various types of

  14. Learning from errors in radiology to improve patient safety.

    Science.gov (United States)

    Saeed, Shaista Afzal; Masroor, Imrana; Shafqat, Gulnaz

    2013-10-01

    To determine the views and practices of trainees and consultant radiologists about error reporting. Cross-sectional survey. Radiology trainees and consultant radiologists in four tertiary care hospitals in Karachi approached in the second quarter of 2011. Participants were enquired as to their grade, sub-specialty interest, whether they kept a record/log of their errors (defined as a mistake that has management implications for the patient), number of errors they made in the last 12 months and the predominant type of error. They were also asked about the details of their department error meetings. All duly completed questionnaires were included in the study while the ones with incomplete information were excluded. A total of 100 radiologists participated in the survey. Of them, 34 were consultants and 66 were trainees. They had a wide range of sub-specialty interest like CT, Ultrasound, etc. Out of the 100 responders, 49 kept a personal record/log of their errors. In response to the recall of approximate errors they made in the last 12 months, 73 (73%) of participants recorded a varied response with 1 - 5 errors mentioned by majority i.e. 47 (64.5%). Most of the radiologists (97%) claimed receiving information about their errors through multiple sources like morbidity/mortality meetings, patients' follow-up, through colleagues and consultants. Perceptual error 66 (66%) were the predominant error type reported. Regular occurrence of error meetings and attending three or more error meetings in the last 12 months was reported by 35% participants. Majority among these described the atmosphere of these error meetings as informative and comfortable (n = 22, 62.8%). It is of utmost importance to develop a culture of learning from mistakes by conducting error meetings and improving the process of recording and addressing errors to enhance patient safety.

  15. Errors in imaging patients in the emergency setting.

    Science.gov (United States)

    Pinto, Antonio; Reginelli, Alfonso; Pinto, Fabio; Lo Re, Giuseppe; Midiri, Federico; Muzj, Carlo; Romano, Luigia; Brunese, Luca

    2016-01-01

    Emergency and trauma care produces a "perfect storm" for radiological errors: uncooperative patients, inadequate histories, time-critical decisions, concurrent tasks and often junior personnel working after hours in busy emergency departments. The main cause of diagnostic errors in the emergency department is the failure to correctly interpret radiographs, and the majority of diagnoses missed on radiographs are fractures. Missed diagnoses potentially have important consequences for patients, clinicians and radiologists. Radiologists play a pivotal role in the diagnostic assessment of polytrauma patients and of patients with non-traumatic craniothoracoabdominal emergencies, and key elements to reduce errors in the emergency setting are knowledge, experience and the correct application of imaging protocols. This article aims to highlight the definition and classification of errors in radiology, the causes of errors in emergency radiology and the spectrum of diagnostic errors in radiography, ultrasonography and CT in the emergency setting.

  16. Verification of the Patient Positioning in the Bellyboard Pelvic Radiotherapy

    International Nuclear Information System (INIS)

    Kasabasic, M.; Faj, D.; Smilovic Radojcic, D.; Svabic, M.; Ivkovic, A.; Jurkovic, S.

    2008-01-01

    The size and shape of the treatment fields applied in radiotherapy account for uncertainties in the daily set-up of the patients during the treatment. We investigated the accuracy of daily patient positioning in the bellyboard pelvic radiotherapy in order to find out the magnitude of the patients movement during the treatment. Translational as well as rotational movements of the patients are explored. Film portal imaging is used in order to find patient positioning error during the treatment of the pelvic region. Patients are treated in the prone position using the bellyboard positioning device. Thirty six patients are included in the study; 15 patients were followed during the whole treatment and 21 during the first 5 consecutive treatment days. The image acquisition was completed in 85 percent and systematic and random positioning errors in 453 images are analyzed. (author)

  17. Positioning errors assessed with kV cone-beam CT for image-guided prostate radiotherapy

    International Nuclear Information System (INIS)

    Li Jiongyan; Guo Xiaomao; Yao Weiqiang; Wang Yanyang; Ma Jinli; Chen Jiayi; Zhang Zhen; Feng Yan

    2010-01-01

    Objective: To assess set-up errors measured with kilovoltage cone-beam CT (KV-CBCT), and the impact of online corrections on margins required to account for set-up variability during IMRT for patients with prostate cancer. Methods: Seven patients with prostate cancer undergoing IMRT were enrolled onto the study. The KV-CBCT scans were acquired at least twice weekly. After initial set-up using the skin marks, a CBCT scan was acquired and registered with the planning CT to determine the setup errors using an auto grey-scale registration software. Corrections would be made by moving the table if the setup errors were considered clinically significant (i. e. , > 2 mm). A second CBCT scan was acquired immediately after the corrections to evaluate the residual error. PTV margins were derived to account for the measured set-up errors and residual errors determined for this group of patients. Results: 197 KV-CBCT images in total were acquired. The random and systematic positioning errors and calculated PTV margins without correction in mm were : a) Lateral 3.1, 2.1, 9.3; b) Longitudinal 1.5, 1.8, 5.1;c) Vertical 4.2, 3.7, 13.0. The random and systematic positioning errors and calculated PTV margin with correction in mm were : a) Lateral 1.1, 0.9, 3.4; b) Longitudinal 0.7, 1.1, 2.5; c) Vertical 1.1, 1.3, 3.7. Conclusions: With the guidance of online KV-CBCT, set-up errors could be reduced significantly for patients with prostate cancer receiving IMRT. The margin required after online CBCT correction for the patients enrolled in the study would be appoximatively 3-4 mm. (authors)

  18. Differences among Job Positions Related to Communication Errors at Construction Sites

    Science.gov (United States)

    Takahashi, Akiko; Ishida, Toshiro

    In a previous study, we classified the communicatio n errors at construction sites as faulty intention and message pattern, inadequate channel pattern, and faulty comprehension pattern. This study seeks to evaluate the degree of risk of communication errors and to investigate differences among people in various job positions in perception of communication error risk . Questionnaires based on the previous study were a dministered to construction workers (n=811; 149 adminis trators, 208 foremen and 454 workers). Administrators evaluated all patterns of communication error risk equally. However, foremen and workers evaluated communication error risk differently in each pattern. The common contributing factors to all patterns wer e inadequate arrangements before work and inadequate confirmation. Some factors were common among patterns but other factors were particular to a specific pattern. To help prevent future accidents at construction sites, administrators should understand how people in various job positions perceive communication errors and propose human factors measures to prevent such errors.

  19. Modeling the probability distribution of positional errors incurred by residential address geocoding

    Directory of Open Access Journals (Sweden)

    Mazumdar Soumya

    2007-01-01

    Full Text Available Abstract Background The assignment of a point-level geocode to subjects' residences is an important data assimilation component of many geographic public health studies. Often, these assignments are made by a method known as automated geocoding, which attempts to match each subject's address to an address-ranged street segment georeferenced within a streetline database and then interpolate the position of the address along that segment. Unfortunately, this process results in positional errors. Our study sought to model the probability distribution of positional errors associated with automated geocoding and E911 geocoding. Results Positional errors were determined for 1423 rural addresses in Carroll County, Iowa as the vector difference between each 100%-matched automated geocode and its true location as determined by orthophoto and parcel information. Errors were also determined for 1449 60%-matched geocodes and 2354 E911 geocodes. Huge (> 15 km outliers occurred among the 60%-matched geocoding errors; outliers occurred for the other two types of geocoding errors also but were much smaller. E911 geocoding was more accurate (median error length = 44 m than 100%-matched automated geocoding (median error length = 168 m. The empirical distributions of positional errors associated with 100%-matched automated geocoding and E911 geocoding exhibited a distinctive Greek-cross shape and had many other interesting features that were not capable of being fitted adequately by a single bivariate normal or t distribution. However, mixtures of t distributions with two or three components fit the errors very well. Conclusion Mixtures of bivariate t distributions with few components appear to be flexible enough to fit many positional error datasets associated with geocoding, yet parsimonious enough to be feasible for nascent applications of measurement-error methodology to spatial epidemiology.

  20. MATLAB implementation of satellite positioning error overbounding by generalized Pareto distribution

    Science.gov (United States)

    Ahmad, Khairol Amali; Ahmad, Shahril; Hashim, Fakroul Ridzuan

    2018-02-01

    In the satellite navigation community, error overbound has been implemented in the process of integrity monitoring. In this work, MATLAB programming is used to implement the overbounding of satellite positioning error CDF. Using a trajectory of reference, the horizontal position errors (HPE) are computed and its non-parametric distribution function is given by the empirical Cumulative Distribution Function (ECDF). According to the results, these errors have a heavy-tailed distribution. Sınce the ECDF of the HPE in urban environment is not Gaussian distributed, the ECDF is overbound with the CDF of the generalized Pareto distribution (GPD).

  1. Patient identification errors: the detective in the laboratory.

    Science.gov (United States)

    Salinas, Maria; López-Garrigós, Maite; Lillo, Rosa; Gutiérrez, Mercedes; Lugo, Javier; Leiva-Salinas, Carlos

    2013-11-01

    The eradication of errors regarding patients' identification is one of the main goals for safety improvement. As clinical laboratory intervenes in 70% of clinical decisions, laboratory safety is crucial in patient safety. We studied the number of Laboratory Information System (LIS) demographic data errors registered in our laboratory during one year. The laboratory attends a variety of inpatients and outpatients. The demographic data of outpatients is registered in the LIS, when they present to the laboratory front desk. The requests from the primary care centers (PCC) are made electronically by the general practitioner. A manual step is always done at the PCC to conciliate the patient identification number in the electronic request with the one in the LIS. Manual registration is done through hospital information system demographic data capture when patient's medical record number is registered in LIS. Laboratory report is always sent out electronically to the patient's electronic medical record. Daily, every demographic data in LIS is manually compared to the request form to detect potential errors. Fewer errors were committed when electronic order was used. There was great error variability between PCC when using the electronic order. LIS demographic data manual registration errors depended on patient origin and test requesting method. Even when using the electronic approach, errors were detected. There was a great variability between PCC even when using this electronic modality; this suggests that the number of errors is still dependent on the personnel in charge of the technology. © 2013.

  2. CALIBRATION ERRORS IN THE CAVITY BEAM POSITION MONITOR SYSTEM AT THE ATF2

    CERN Document Server

    Cullinan, F; Joshi, N; Lyapin, A

    2011-01-01

    It has been shown at the Accelerator Test Facility at KEK, that it is possible to run a system of 37 cavity beam position monitors (BPMs) and achieve high working resolution. However, stability of the calibration constants (position scale and radio frequency (RF) phase) over a three/four week running period is yet to be demonstrated. During the calibration procedure, random beam jitter gives rise to a statistical error in the position scale and slow orbit drift in position and tilt causes systematic errors in both the position scale and RF phase. These errors are dominant and have been evaluated for each BPM. The results are compared with the errors expected after a tested method of beam jitter subtraction has been applied.

  3. Disclosing harmful medical errors to patients: tackling three tough cases.

    Science.gov (United States)

    Gallagher, Thomas H; Bell, Sigall K; Smith, Kelly M; Mello, Michelle M; McDonald, Timothy B

    2009-09-01

    A gap exists between recommendations to disclose errors to patients and current practice. This gap may reflect important, yet unanswered questions about implementing disclosure principles. We explore some of these unanswered questions by presenting three real cases that pose challenging disclosure dilemmas. The first case involves a pancreas transplant that failed due to the pancreas graft being discarded, an error that was not disclosed partly because the family did not ask clarifying questions. Relying on patient or family questions to determine the content of disclosure is problematic. We propose a standard of materiality that can help clinicians to decide what information to disclose. The second case involves a fatal diagnostic error that the patient's widower was unaware had happened. The error was not disclosed out of concern that disclosure would cause the widower more harm than good. This case highlights how institutions can overlook patients' and families' needs following errors and emphasizes that benevolent deception has little role in disclosure. Institutions should consider whether involving neutral third parties could make disclosures more patient centered. The third case presents an intraoperative cardiac arrest due to a large air embolism where uncertainty around the clinical event was high and complicated the disclosure. Uncertainty is common to many medical errors but should not deter open conversations with patients and families about what is and is not known about the event. Continued discussion within the medical profession about applying disclosure principles to real-world cases can help to better meet patients' and families' needs following medical errors.

  4. Error identification and recovery by student nurses using human patient simulation: opportunity to improve patient safety.

    Science.gov (United States)

    Henneman, Elizabeth A; Roche, Joan P; Fisher, Donald L; Cunningham, Helene; Reilly, Cheryl A; Nathanson, Brian H; Henneman, Philip L

    2010-02-01

    This study examined types of errors that occurred or were recovered in a simulated environment by student nurses. Errors occurred in all four rule-based error categories, and all students committed at least one error. The most frequent errors occurred in the verification category. Another common error was related to physician interactions. The least common errors were related to coordinating information with the patient and family. Our finding that 100% of student subjects committed rule-based errors is cause for concern. To decrease errors and improve safe clinical practice, nurse educators must identify effective strategies that students can use to improve patient surveillance. Copyright 2010 Elsevier Inc. All rights reserved.

  5. Medication Administration Errors Involving Paediatric In-Patients in a ...

    African Journals Online (AJOL)

    Erah

    In-Patients in a Hospital in Ethiopia. Yemisirach Feleke ... Purpose: To assess the type and frequency of medication administration errors (MAEs) in the paediatric ward of .... prescribers, does not go beyond obeying ... specialists, 43 general practitioners, 2 health officers ..... Medication Errors, International Council of Nurses.

  6. Patient positioning and supporting arrangement

    International Nuclear Information System (INIS)

    Heavens, M.; James, R.C.; Slinn, D.S.

    1980-01-01

    This patent specification describes an E.M.I. claim relating to a patient positioning and support arrangement for a computerised axial tomography system, the arrangement comprising a curved platter upon which the patient can be disposed, a table having a curved groove to accommodate the platter, and means for driving the platter slidably along the groove; the platter being formed of a substantially rigid platform shaped to conform to the groove, and a shroud, secured to the platter and disposed between the platter and the surface of the groove, so as to permit the platter to slide smoothly. (U.K.)

  7. Positional accommodative intraocular lens power error induced by the estimation of the corneal power and the effective lens position

    Directory of Open Access Journals (Sweden)

    David P Piñero

    2015-01-01

    Full Text Available Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP. Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52-77 years and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (P IOLadj based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (n kadj for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELP adj . P IOLadj was compared to the real IOL power implanted (P IOLReal , calculated with the SRK-T formula and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between P IOLReal and P IOLadj when ELP adj was used (P = 0.10, with a range of agreement between calculations of 1.23 D. In contrast, P IOLReal was significantly higher when compared to P IOLadj without using ELP adj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.

  8. Negative cognitive errors and positive illusions for negative divorce events: predictors of children's psychological adjustment.

    Science.gov (United States)

    Mazur, E; Wolchik, S A; Sandler, I N

    1992-12-01

    This study examined the relations among negative cognitive errors regarding hypothetical negative divorce events, positive illusions about those same events, actual divorce events, and psychological adjustment in 38 8- to 12-year-old children whose parents had divorced within the previous 2 years. Children's scores on a scale of negative cognitive errors (catastrophizing, overgeneralizing, and personalizing) correlated significantly with self-reported symptoms of anxiety and self-esteem, and with maternal reports of behavior problems. Children's scores on a scale measuring positive illusions (high self-regard, illusion of personal control, and optimism for the future) correlated significantly with less self-reported aggression. Both appraisal types accounted for variance in some measures of symptomatology beyond that explained by actual events. There was no significant association between children's negative cognitive errors and positive illusions. The implications of these results for theories of negative cognitive errors and of positive illusions, as well as for future research, are discussed.

  9. Errors in laboratory medicine: practical lessons to improve patient safety.

    Science.gov (United States)

    Howanitz, Peter J

    2005-10-01

    Patient safety is influenced by the frequency and seriousness of errors that occur in the health care system. Error rates in laboratory practices are collected routinely for a variety of performance measures in all clinical pathology laboratories in the United States, but a list of critical performance measures has not yet been recommended. The most extensive databases describing error rates in pathology were developed and are maintained by the College of American Pathologists (CAP). These databases include the CAP's Q-Probes and Q-Tracks programs, which provide information on error rates from more than 130 interlaboratory studies. To define critical performance measures in laboratory medicine, describe error rates of these measures, and provide suggestions to decrease these errors, thereby ultimately improving patient safety. A review of experiences from Q-Probes and Q-Tracks studies supplemented with other studies cited in the literature. Q-Probes studies are carried out as time-limited studies lasting 1 to 4 months and have been conducted since 1989. In contrast, Q-Tracks investigations are ongoing studies performed on a yearly basis and have been conducted only since 1998. Participants from institutions throughout the world simultaneously conducted these studies according to specified scientific designs. The CAP has collected and summarized data for participants about these performance measures, including the significance of errors, the magnitude of error rates, tactics for error reduction, and willingness to implement each of these performance measures. A list of recommended performance measures, the frequency of errors when these performance measures were studied, and suggestions to improve patient safety by reducing these errors. Error rates for preanalytic and postanalytic performance measures were higher than for analytic measures. Eight performance measures were identified, including customer satisfaction, test turnaround times, patient identification

  10. Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Sen; Li, Guangjun; Wang, Maojie; Jiang, Qinfeng; Zhang, Yingjie [State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan (China); Wei, Yuquan, E-mail: yuquawei@vip.sina.com [State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan (China)

    2013-07-01

    The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

  11. An IMU-Aided Body-Shadowing Error Compensation Method for Indoor Bluetooth Positioning.

    Science.gov (United States)

    Deng, Zhongliang; Fu, Xiao; Wang, Hanhua

    2018-01-20

    Research on indoor positioning technologies has recently become a hotspot because of the huge social and economic potential of indoor location-based services (ILBS). Wireless positioning signals have a considerable attenuation in received signal strength (RSS) when transmitting through human bodies, which would cause significant ranging and positioning errors in RSS-based systems. This paper mainly focuses on the body-shadowing impairment of RSS-based ranging and positioning, and derives a mathematical expression of the relation between the body-shadowing effect and the positioning error. In addition, an inertial measurement unit-aided (IMU-aided) body-shadowing detection strategy is designed, and an error compensation model is established to mitigate the effect of body-shadowing. A Bluetooth positioning algorithm with body-shadowing error compensation (BP-BEC) is then proposed to improve both the positioning accuracy and the robustness in indoor body-shadowing environments. Experiments are conducted in two indoor test beds, and the performance of both the BP-BEC algorithm and the algorithms without body-shadowing error compensation (named no-BEC) is evaluated. The results show that the BP-BEC outperforms the no-BEC by about 60.1% and 73.6% in terms of positioning accuracy and robustness, respectively. Moreover, the execution time of the BP-BEC algorithm is also evaluated, and results show that the convergence speed of the proposed algorithm has an insignificant effect on real-time localization.

  12. An IMU-Aided Body-Shadowing Error Compensation Method for Indoor Bluetooth Positioning

    Directory of Open Access Journals (Sweden)

    Zhongliang Deng

    2018-01-01

    Full Text Available Research on indoor positioning technologies has recently become a hotspot because of the huge social and economic potential of indoor location-based services (ILBS. Wireless positioning signals have a considerable attenuation in received signal strength (RSS when transmitting through human bodies, which would cause significant ranging and positioning errors in RSS-based systems. This paper mainly focuses on the body-shadowing impairment of RSS-based ranging and positioning, and derives a mathematical expression of the relation between the body-shadowing effect and the positioning error. In addition, an inertial measurement unit-aided (IMU-aided body-shadowing detection strategy is designed, and an error compensation model is established to mitigate the effect of body-shadowing. A Bluetooth positioning algorithm with body-shadowing error compensation (BP-BEC is then proposed to improve both the positioning accuracy and the robustness in indoor body-shadowing environments. Experiments are conducted in two indoor test beds, and the performance of both the BP-BEC algorithm and the algorithms without body-shadowing error compensation (named no-BEC is evaluated. The results show that the BP-BEC outperforms the no-BEC by about 60.1% and 73.6% in terms of positioning accuracy and robustness, respectively. Moreover, the execution time of the BP-BEC algorithm is also evaluated, and results show that the convergence speed of the proposed algorithm has an insignificant effect on real-time localization.

  13. Reduction of digital errors of digital charge division type position-sensitive detectors

    International Nuclear Information System (INIS)

    Uritani, A.; Yoshimura, K.; Takenaka, Y.; Mori, C.

    1994-01-01

    It is well known that ''digital errors'', i.e. differential non-linearity, appear in a position profile of radiation interactions when the profile is obtained with a digital charge-division-type position-sensitive detector. Two methods are presented to reduce the digital errors. They are the methods using logarithmic amplifiers and a weighting function. The validities of these two methods have been evaluated mainly by computer simulation. These methods can considerably reduce the digital errors. The best results are obtained when both methods are applied. ((orig.))

  14. Treatment delay and radiological errors in patients with bone metastases

    International Nuclear Information System (INIS)

    Ichinohe, K.; Takahashi, M.; Tooyama, N.

    2003-01-01

    During routine investigations, we are surprised to find that therapy for bone metastases is sometimes delayed for a considerable period of time. To determine the extent of this delay and its causes, we reviewed the medical records of symptomatic patients seen at our hospital who had been recently diagnosed as having bone metastases for the last four years. The treatment delay was defined as the interval between presentation with symptoms and definitive treatment for bone metastases. The diagnostic delay was defined as the interval between presentation with symptoms and diagnosis of bone metastases. The results of diagnostic radiological examinations were also reviewed for errors. The study population included 76 males and 34 females with a median age of 66 years. Most bone metastases were diagnosed radiologically. Over 75% of patients were treated with radiotherapy. The treatment delay ranged from 2 to 307 days, with a mean of 53.3 days. In 490 radiological studies reviewed, we identified 166 (33.9%) errors concerning 62 (56.4%) patients. The diagnostic delay was significantly longer for patients with radiological errors than for patients without radiological errors (P < 0.001), and much of it was due to radiological errors. In conclusion, the treatment delay in patients with symptomatic bone metastases was much longer than expected, and much of it was caused by radiological errors. Considerable efforts should therefore be made to more carefully examine the radiological studies in order to ensure prompt treatment of bone metastases. (author)

  15. A vignette study to examine health care professionals' attitudes towards patient involvement in error prevention.

    Science.gov (United States)

    Schwappach, David L B; Frank, Olga; Davis, Rachel E

    2013-10-01

    Various authorities recommend the participation of patients in promoting patient safety, but little is known about health care professionals' (HCPs') attitudes towards patients' involvement in safety-related behaviours. To investigate how HCPs evaluate patients' behaviours and HCP responses to patient involvement in the behaviour, relative to different aspects of the patient, the involved HCP and the potential error. Cross-sectional fractional factorial survey with seven factors embedded in two error scenarios (missed hand hygiene, medication error). Each survey included two randomized vignettes that described the potential error, a patient's reaction to that error and the HCP response to the patient. Twelve hospitals in Switzerland. A total of 1141 HCPs (response rate 45%). Approval of patients' behaviour, HCP response to the patient, anticipated effects on the patient-HCP relationship, HCPs' support for being asked the question, affective response to the vignettes. Outcomes were measured on 7-point scales. Approval of patients' safety-related interventions was generally high and largely affected by patients' behaviour and correct identification of error. Anticipated effects on the patient-HCP relationship were much less positive, little correlated with approval of patients' behaviour and were mainly determined by the HCP response to intervening patients. HCPs expressed more favourable attitudes towards patients intervening about a medication error than about hand sanitation. This study provides the first insights into predictors of HCPs' attitudes towards patient engagement in safety. Future research is however required to assess the generalizability of the findings into practice before training can be designed to address critical issues. © 2012 John Wiley & Sons Ltd.

  16. SU-E-J-94: Positioning Errors Resulting From Using Bony Anatomy Alignment for Treating SBRT Lung Tumor

    International Nuclear Information System (INIS)

    Frame, C; Ding, G

    2014-01-01

    Purpose: To quantify patient setups errors based on bony anatomy registration rather than 3D tumor alignment for SBRT lung treatments. Method: A retrospective study was performed for patients treated with lung SBRT and imaged with kV cone beam computed tomography (kV-CBCT) image-guidance. Daily CBCT images were registered to treatment planning CTs based on bony anatomy alignment and then inter-fraction tumor movement was evaluated by comparing shift in the tumor center in the medial-lateral, anterior-posterior, and superior-inferior directions. The PTV V100% was evaluated for each patient based on the average daily tumor displacement to assess the impact of the positioning error on the target coverage when the registrations were based on bony anatomy. Of the 35 patients studied, 15 were free-breathing treatments, 10 used abdominal compression with a stereotactic body frame, and the remaining 10 were performed with BodyFIX vacuum bags. Results: For free-breathing treatments, the range of tumor displacement error is between 1–6 mm in the medial-lateral, 1–13 mm in the anterior-posterior, and 1–7 mm in the superior-inferior directions. These positioning errors lead to 6–22% underdose coverage for PTV - V100% . Patients treated with abdominal compression immobilization showed positional errors of 0–4mm mediallaterally, 0–3mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% underdose ranging between 6–17%. For patients immobilized with the vacuum bags, the positional errors were found to be 0–1 mm medial-laterally, 0–1mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% under dose ranging between 5–6% only. Conclusion: It is necessary to align the tumor target by using 3D image guidance to ensure adequate tumor coverage before performing SBRT lung treatments. The BodyFIX vacuum bag immobilization method has the least positioning errors among the three methods studied when bony anatomy is used for

  17. Visual memory errors in Parkinson's disease patient with visual hallucinations.

    Science.gov (United States)

    Barnes, J; Boubert, L

    2011-03-01

    The occurrences of visual hallucinations seem to be more prevalent in low light and hallucinators tend to be more prone to false positive type errors in memory tasks. Here we investigated whether the richness of stimuli does indeed affect recognition differently in hallucinating and nonhallucinating participants, and if so whether this difference extends to identifying spatial context. We compared 36 Parkinson's disease (PD) patients with visual hallucinations, 32 Parkinson's patients without hallucinations, and 36 age-matched controls, on a visual memory task where color and black and white pictures were presented at different locations. Participants had to recognize the pictures among distracters along with the location of the stimulus. Findings revealed clear differences in performance between the groups. Both PD groups had impaired recognition compared to the controls, but those with hallucinations were significantly more impaired on black and white than on color stimuli. In addition, the group with hallucinations was significantly impaired compared to the other two groups on spatial memory. We suggest that not only do PD patients have poorer recognition of pictorial stimuli than controls, those who present with visual hallucinations appear to be more heavily reliant on bottom up sensory input and impaired on spatial ability.

  18. Performance of muon reconstruction including Alignment Position Errors for 2016 Collision Data

    CERN Document Server

    CMS Collaboration

    2016-01-01

    From 2016 Run muon reconstruction is using non-zero Alignment Position Errors to account for the residual uncertainties of muon chambers' positions. Significant improvements are obtained in particular for the startup phase after opening/closing the muon detector. Performance results are presented for real data and MC simulations, related to both the offline reconstruction and the High-Level Trigger.

  19. Consonant acquisition: a first approach to the distribution of errors in four positions in the word

    Directory of Open Access Journals (Sweden)

    Silvia Llach

    2012-12-01

    Full Text Available The goal of this study is to describe the behavior of errors in two types of onsets (initial and intervocalic and two types of codas (in the middle and end of the word in order to determine if any of these positions are more prone to specific types of errors than the others.We have looked into the errors that are frequently produced in these four contexts during the acquisition of consonant sounds in the Catalan language. The data were taken from a study on the acquisition of consonants in Catalan, carried out on 90 children between the ages of 3 and 5 years from several kindergarten schools. The results do show that there are characteristic errors depending on the position within the word.

  20. Compensation for positioning error of industrial robot for flexible vision measuring system

    Science.gov (United States)

    Guo, Lei; Liang, Yajun; Song, Jincheng; Sun, Zengyu; Zhu, Jigui

    2013-01-01

    Positioning error of robot is a main factor of accuracy of flexible coordinate measuring system which consists of universal industrial robot and visual sensor. Present compensation methods for positioning error based on kinematic model of robot have a significant limitation that it isn't effective in the whole measuring space. A new compensation method for positioning error of robot based on vision measuring technique is presented. One approach is setting global control points in measured field and attaching an orientation camera to vision sensor. Then global control points are measured by orientation camera to calculate the transformation relation from the current position of sensor system to global coordinate system and positioning error of robot is compensated. Another approach is setting control points on vision sensor and two large field cameras behind the sensor. Then the three dimensional coordinates of control points are measured and the pose and position of sensor is calculated real-timely. Experiment result shows the RMS of spatial positioning is 3.422mm by single camera and 0.031mm by dual cameras. Conclusion is arithmetic of single camera method needs to be improved for higher accuracy and accuracy of dual cameras method is applicable.

  1. Refractive errors in presbyopic patients in Kano, Nigeria

    African Journals Online (AJOL)

    Annals of African Medicine, Vol. ... Information extracted includes patient's age, sex, and types of refractive error. ... All patients had basic eye examination and streak retinoscopy at two third meter working distance. ... symptoms may start earlier or later than this age .... presbyopia was associated with reduced workers'.

  2. Detection of Patients at High Risk of Medication Errors

    DEFF Research Database (Denmark)

    Sædder, Eva Aggerholm; Lisby, Marianne; Nielsen, Lars Peter

    2016-01-01

    Medication errors (MEs) are preventable and can result in patient harm and increased expenses in the healthcare system in terms of hospitalization, prolonged hospitalizations and even death. We aimed to develop a screening tool to detect acutely admitted patients at low or high risk of MEs...

  3. Patients' knowledge and perceived reactions to medical errors in a ...

    African Journals Online (AJOL)

    Severity of error (88.5%) and the perception of negligence mediated intention to litigate. Voluntary disclosure significantly reduced patients' intention to litigate caregivers (chi2=3.584; df=1; P=0.053). Frustration/anger was not more likely to influence patient to litigate than feelings of resignation/forgiveness (chi2=2.156; df=1; ...

  4. The method to evaluate the position error in graphic positioning technology

    Institute of Scientific and Technical Information of China (English)

    Huiqing Lu(卢慧卿); Baoguang Wang(王宝光); Lishuang Liu(刘力双); Yabiao Li(李亚标)

    2004-01-01

    In the measurement of automobile body-in-white, it has been widely studied to position the two dimensional(2D)visual sensors with high precision. In this paper a graphic positioning method is proposed,a hollow tetrahedron is used for a positioning target to replace all the edges of a standard automobile body.A 2D visual sensor can be positioned through adjusting two triangles to be superposed on a screen of the computer, so it is very important to evaluate the superposition precision of the two triangles. Several methods are discussed and the least square method is adopted at last, it makes the adjustment more easy and intuitive with high precision.

  5. Calculation errors of Set-up in patients with tumor location of prostate. Exploratory study; Calculo de errores de Set-up en pacientes con localizacion tumoral de prostata. Estudio exploratorio

    Energy Technology Data Exchange (ETDEWEB)

    Donis Gil, S.; Robayna Duque, B. E.; Jimenez Sosa, A.; Hernandez Armas, O.; Gonzalez Martin, A. E.; Hernandez Armas, J.

    2013-07-01

    The calculation of SM is done from errors in positioning (set-up). These errors are calculated from movements in 3D of the patient. This paper is an exploratory study of 20 patients with tumor location of prostate in which errors of set-up for two protocols of work are evaluated. (Author)

  6. Circular Array of Magnetic Sensors for Current Measurement: Analysis for Error Caused by Position of Conductor.

    Science.gov (United States)

    Yu, Hao; Qian, Zheng; Liu, Huayi; Qu, Jiaqi

    2018-02-14

    This paper analyzes the measurement error, caused by the position of the current-carrying conductor, of a circular array of magnetic sensors for current measurement. The circular array of magnetic sensors is an effective approach for AC or DC non-contact measurement, as it is low-cost, light-weight, has a large linear range, wide bandwidth, and low noise. Especially, it has been claimed that such structure has excellent reduction ability for errors caused by the position of the current-carrying conductor, crosstalk current interference, shape of the conduction cross-section, and the Earth's magnetic field. However, the positions of the current-carrying conductor-including un-centeredness and un-perpendicularity-have not been analyzed in detail until now. In this paper, for the purpose of having minimum measurement error, a theoretical analysis has been proposed based on vector inner and exterior product. In the presented mathematical model of relative error, the un-center offset distance, the un-perpendicular angle, the radius of the circle, and the number of magnetic sensors are expressed in one equation. The comparison of the relative error caused by the position of the current-carrying conductor between four and eight sensors is conducted. Tunnel magnetoresistance (TMR) sensors are used in the experimental prototype to verify the mathematical model. The analysis results can be the reference to design the details of the circular array of magnetic sensors for current measurement in practical situations.

  7. Lateral positioning for critically ill adult patients.

    Science.gov (United States)

    Hewitt, Nicky; Bucknall, Tracey; Faraone, Nardene M

    2016-05-12

    Critically ill patients require regular body position changes to minimize the adverse effects of bed rest, inactivity and immobilization. However, uncertainty surrounds the effectiveness of lateral positioning for improving pulmonary gas exchange, aiding drainage of tracheobronchial secretions and preventing morbidity. In addition, it is unclear whether the perceived risk levied by respiratory and haemodynamic instability upon turning critically ill patients outweighs the respiratory benefits of side-to-side rotation. Thus, lack of certainty may contribute to variation in positioning practice and equivocal patient outcomes. To evaluate effects of the lateral position compared with other body positions on patient outcomes (mortality, morbidity and clinical adverse events) in critically ill adult patients. (Clinical adverse events include hypoxaemia, hypotension, low oxygen delivery and global indicators of impaired tissue oxygenation.) We examined single use of the lateral position (i.e. on the right or left side) and repeat use of the lateral position (i.e. lateral positioning) within a positioning schedule. We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 5), MEDLINE (1950 to 23 May 2015), the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1937 to 23 May 2015), the Allied and Complementary Medicine Database (AMED) (1984 to 23 May 2015), Latin American Caribbean Health Sciences Literature (LILACS) (1901 to 23 May 2015), Web of Science (1945 to 23 May 2015), Index to Theses in Great Britain and Ireland (1950 to 23 May 2015), Trove (2009 to 23 May 2015; previously Australasian Digital Theses Program (1997 to December 2008)) and Proquest Dissertations and Theses (2009 to 23 May 2015; previously Proquest Digital Dissertations (1980 to 23 May 2015)). We handsearched the reference lists of potentially relevant reports and two nursing journals. We included randomized and quasi-randomized trials examining effects of

  8. Decreasing patient identification band errors by standardizing processes.

    Science.gov (United States)

    Walley, Susan Chu; Berger, Stephanie; Harris, Yolanda; Gallizzi, Gina; Hayes, Leslie

    2013-04-01

    Patient identification (ID) bands are an essential component in patient ID. Quality improvement methodology has been applied as a model to reduce ID band errors although previous studies have not addressed standardization of ID bands. Our specific aim was to decrease ID band errors by 50% in a 12-month period. The Six Sigma DMAIC (define, measure, analyze, improve, and control) quality improvement model was the framework for this study. ID bands at a tertiary care pediatric hospital were audited from January 2011 to January 2012 with continued audits to June 2012 to confirm the new process was in control. After analysis, the major improvement strategy implemented was standardization of styles of ID bands and labels. Additional interventions included educational initiatives regarding the new ID band processes and disseminating institutional and nursing unit data. A total of 4556 ID bands were audited with a preimprovement ID band error average rate of 9.2%. Significant variation in the ID band process was observed, including styles of ID bands. Interventions were focused on standardization of the ID band and labels. The ID band error rate improved to 5.2% in 9 months (95% confidence interval: 2.5-5.5; P error rates. This decrease in ID band error rates was maintained over the subsequent 8 months.

  9. Clinical measuring system for the form and position errors of circular workpieces using optical fiber sensors

    Science.gov (United States)

    Tan, Jiubin; Qiang, Xifu; Ding, Xuemei

    1991-08-01

    Optical sensors have two notable advantages in modern precision measurement. One is that they can be used in nondestructive measurement because the sensors need not touch the surfaces of workpieces in measuring. The other one is that they can strongly resist electromagnetic interferences, vibrations, and noises, so they are suitable to be used in machining sites. But the drift of light intensity and the changing of the reflection coefficient at different measuring positions of a workpiece may have great influence on measured results. To solve the problem, a spectroscopic differential characteristic compensating method is put forward. The method can be used effectively not only in compensating the measuring errors resulted from the drift of light intensity but also in eliminating the influence to measured results caused by the changing of the reflection coefficient. Also, the article analyzes the possibility of and the means of separating data errors of a clinical measuring system for form and position errors of circular workpieces.

  10. Patient identification errors are common in a simulated setting.

    Science.gov (United States)

    Henneman, Philip L; Fisher, Donald L; Henneman, Elizabeth A; Pham, Tuan A; Campbell, Megan M; Nathanson, Brian H

    2010-06-01

    We evaluate the frequency and accuracy of health care workers verifying patient identity before performing common tasks. The study included prospective, simulated patient scenarios with an eye-tracking device that showed where the health care workers looked. Simulations involved nurses administering an intravenous medication, technicians labeling a blood specimen, and clerks applying an identity band. Participants were asked to perform their assigned task on 3 simulated patients, and the third patient had a different date of birth and medical record number than the identity information on the artifact label specific to the health care workers' task. Health care workers were unaware that the focus of the study was patient identity. Sixty-one emergency health care workers participated--28 nurses, 16 technicians, and 17 emergency service associates--in 183 patient scenarios. Sixty-one percent of health care workers (37/61) caught the identity error (61% nurses, 94% technicians, 29% emergency service associates). Thirty-nine percent of health care workers (24/61) performed their assigned task on the wrong patient (39% nurses, 6% technicians, 71% emergency service associates). Eye-tracking data were available for 73% of the patient scenarios (133/183). Seventy-four percent of health care workers (74/100) failed to match the patient to the identity band (87% nurses, 49% technicians). Twenty-seven percent of health care workers (36/133) failed to match the artifact to the patient or the identity band before performing their task (33% nurses, 9% technicians, 33% emergency service associates). Fifteen percent (5/33) of health care workers who completed the steps to verify patient identity on the patient with the identification error still failed to recognize the error. Wide variation exists among health care workers verifying patient identity before performing everyday tasks. Education, process changes, and technology are needed to improve the frequency and accuracy of

  11. Rail-guided robotic end-effector position error due to rail compliance and ship motion

    NARCIS (Netherlands)

    Borgerink, Dian; Stegenga, J.; Brouwer, Dannis Michel; Woertche, H.J.; Stramigioli, Stefano

    2014-01-01

    A rail-guided robotic system is currently being designed for the inspection of ballast water tanks in ships. This robotic system will manipulate sensors toward the interior walls of the tank. In this paper, the influence of rail compliance on the end-effector position error due to ship movement is

  12. The role of positional errors while interpolating soil organic carbon contents using satellite imagery

    NARCIS (Netherlands)

    Samsonova, V.P.; Meshalkina, J.L.; Blagoveschensky, Y.N.; Yaroslavtsev, A.M.; Stoorvogel, J.J.

    2018-01-01

    Increasingly, soil surveys make use of a combination of legacy data, ancillary data and new field data. While combining the different sources of information, positional errors can play a large role. For example, the spatial discrepancy between remote sensing images and field data can depend on

  13. Compensation of position errors in passivity based teleoperation over packet switched communication networks

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    Because of the use of scattering based communication channels, passivity based telemanipulation systems can be subject to a steady state position error between master and slave robots. In this paper, we consider the case in which the passive master and slave sides communicate through a packet

  14. Robust Adaptive Beamforming with Sensor Position Errors Using Weighted Subspace Fitting-Based Covariance Matrix Reconstruction.

    Science.gov (United States)

    Chen, Peng; Yang, Yixin; Wang, Yong; Ma, Yuanliang

    2018-05-08

    When sensor position errors exist, the performance of recently proposed interference-plus-noise covariance matrix (INCM)-based adaptive beamformers may be severely degraded. In this paper, we propose a weighted subspace fitting-based INCM reconstruction algorithm to overcome sensor displacement for linear arrays. By estimating the rough signal directions, we construct a novel possible mismatched steering vector (SV) set. We analyze the proximity of the signal subspace from the sample covariance matrix (SCM) and the space spanned by the possible mismatched SV set. After solving an iterative optimization problem, we reconstruct the INCM using the estimated sensor position errors. Then we estimate the SV of the desired signal by solving an optimization problem with the reconstructed INCM. The main advantage of the proposed algorithm is its robustness against SV mismatches dominated by unknown sensor position errors. Numerical examples show that even if the position errors are up to half of the assumed sensor spacing, the output signal-to-interference-plus-noise ratio is only reduced by 4 dB. Beam patterns plotted using experiment data show that the interference suppression capability of the proposed beamformer outperforms other tested beamformers.

  15. Positive Beliefs about Errors as an Important Element of Adaptive Individual Dealing with Errors during Academic Learning

    Science.gov (United States)

    Tulis, Maria; Steuer, Gabriele; Dresel, Markus

    2018-01-01

    Research on learning from errors gives reason to assume that errors provide a high potential to facilitate deep learning if students are willing and able to take these learning opportunities. The first aim of this study was to analyse whether beliefs about errors as learning opportunities can be theoretically and empirically distinguished from…

  16. Contribution of refractive errors to visual impairment in patients at ...

    African Journals Online (AJOL)

    Objective: To determine the contribution of refractive error to visual impairment in visually impaired patients attending Korle-Bu Teaching Hospital, Ghana. Method: This study was conducted over a period of 1 year beginning October 2002 at Korle-Bu Teaching Hospital. Every 4th consecutive new case attending the eye ...

  17. Quantitative analysis of the errors positioning of a multi leaf collimator for volumetric arcoterapia treatments

    International Nuclear Information System (INIS)

    Gomez Gonzalez, N.; Garcia Repiso, S.; Martin Rincon, C.; Cons Perez, N.; Saez Beltran, M.; Delgado Aparicio, J. M.; Perez alvarez, M. E.; Verde Velasco, J. M.; Ramos Pacho, J. A.; Sena Espinel, E. de

    2013-01-01

    The precision in the positioning of the multi leaf collimation system of a linear accelerator is critical, especially in treatments of IMRT, where small mistakes can cause relevant dosimetry discrepancies regarding the calculated plan. To assess the accuracy and repeatability of the blades positioning can be used controls, including the one known as fence test whose image pattern allows you to find anomalies in a visual way. The objective of this study is to develop a method which allows to quantify the positioning errors of the multi leaf collimator from this test. (Author)

  18. Observations of geographically correlated orbit errors for TOPEX/Poseidon using the global positioning system

    Science.gov (United States)

    Christensen, E. J.; Haines, B. J.; Mccoll, K. C.; Nerem, R. S.

    1994-01-01

    We have compared Global Positioning System (GPS)-based dynamic and reduced-dynamic TOPEX/Poseidon orbits over three 10-day repeat cycles of the ground-track. The results suggest that the prelaunch joint gravity model (JGM-1) introduces geographically correlated errors (GCEs) which have a strong meridional dependence. The global distribution and magnitude of these GCEs are consistent with a prelaunch covariance analysis, with estimated and predicted global rms error statistics of 2.3 and 2.4 cm rms, respectively. Repeating the analysis with the post-launch joint gravity model (JGM-2) suggests that a portion of the meridional dependence observed in JGM-1 still remains, with global rms error of 1.2 cm.

  19. Positive phase error from parallel conductance in tetrapolar bio-impedance measurements and its compensation

    Directory of Open Access Journals (Sweden)

    Ivan M Roitt

    2010-01-01

    Full Text Available Bioimpedance measurements are of great use and can provide considerable insight into biological processes.  However, there are a number of possible sources of measurement error that must be considered.  The most dominant source of error is found in bipolar measurements where electrode polarisation effects are superimposed on the true impedance of the sample.  Even with the tetrapolar approach that is commonly used to circumvent this issue, other errors can persist. Here we characterise the positive phase and rise in impedance magnitude with frequency that can result from the presence of any parallel conductive pathways in the measurement set-up.  It is shown that fitting experimental data to an equivalent electrical circuit model allows for accurate determination of the true sample impedance as validated through finite element modelling (FEM of the measurement chamber.  Finally, the model is used to extract dispersion information from cell cultures to characterise their growth.

  20. Early math and reading achievement are associated with the error positivity

    Directory of Open Access Journals (Sweden)

    Matthew H. Kim

    2016-12-01

    Full Text Available Executive functioning (EF and motivation are associated with academic achievement and error-related ERPs. The present study explores whether early academic skills predict variability in the error-related negativity (ERN and error positivity (Pe. Data from 113 three- to seven-year-old children in a Go/No-Go task revealed that stronger early reading and math skills predicted a larger Pe. Closer examination revealed that this relation was quadratic and significant for children performing at or near grade level, but not significant for above-average achievers. Early academics did not predict the ERN. These findings suggest that the Pe – which reflects individual differences in motivational processes as well as attention – may be associated with early academic achievement.

  1. SU-E-T-377: Inaccurate Positioning Might Introduce Significant MapCheck Calibration Error in Flatten Filter Free Beams

    International Nuclear Information System (INIS)

    Wang, S; Chao, C; Chang, J

    2014-01-01

    Purpose: This study investigates the calibration error of detector sensitivity for MapCheck due to inaccurate positioning of the device, which is not taken into account by the current commercial iterative calibration algorithm. We hypothesize the calibration is more vulnerable to the positioning error for the flatten filter free (FFF) beams than the conventional flatten filter flattened beams. Methods: MapCheck2 was calibrated with 10MV conventional and FFF beams, with careful alignment and with 1cm positioning error during calibration, respectively. Open fields of 37cmx37cm were delivered to gauge the impact of resultant calibration errors. The local calibration error was modeled as a detector independent multiplication factor, with which propagation error was estimated with positioning error from 1mm to 1cm. The calibrated sensitivities, without positioning error, were compared between the conventional and FFF beams to evaluate the dependence on the beam type. Results: The 1cm positioning error leads to 0.39% and 5.24% local calibration error in the conventional and FFF beams respectively. After propagating to the edges of MapCheck, the calibration errors become 6.5% and 57.7%, respectively. The propagation error increases almost linearly with respect to the positioning error. The difference of sensitivities between the conventional and FFF beams was small (0.11 ± 0.49%). Conclusion: The results demonstrate that the positioning error is not handled by the current commercial calibration algorithm of MapCheck. Particularly, the calibration errors for the FFF beams are ~9 times greater than those for the conventional beams with identical positioning error, and a small 1mm positioning error might lead to up to 8% calibration error. Since the sensitivities are only slightly dependent of the beam type and the conventional beam is less affected by the positioning error, it is advisable to cross-check the sensitivities between the conventional and FFF beams to detect

  2. Direct focusing error correction with ring-wide TBT beam position data

    International Nuclear Information System (INIS)

    Yang, M.J.

    2011-01-01

    Turn-By-Turn (TBT) betatron oscillation data is a very powerful tool in studying machine optics. Hundreds and thousands of turns of free oscillations are taken in just few tens of milliseconds. With beam covering all positions and angles at every location TBT data can be used to diagnose focusing errors almost instantly. This paper describes a new approach that observes focusing error collectively over all available TBT data to find the optimized quadrupole strength, one location at a time. Example will be shown and other issues will be discussed. The procedure presented clearly has helped to reduce overall deviations significantly, with relative ease. Sextupoles, being a permanent feature of the ring, will need to be incorporated into the model. While cumulative effect from all sextupoles around the ring may be negligible on turn-to-turn basis it is not so in this transfer line analysis. It should be noted that this procedure is not limited to looking for quadrupole errors. By modifying the target of minimization it could in principle be used to look for skew quadrupole errors and sextupole errors as well.

  3. A new stochastic model considering satellite clock interpolation errors in precise point positioning

    Science.gov (United States)

    Wang, Shengli; Yang, Fanlin; Gao, Wang; Yan, Lizi; Ge, Yulong

    2018-03-01

    Precise clock products are typically interpolated based on the sampling interval of the observational data when they are used for in precise point positioning. However, due to the occurrence of white noise in atomic clocks, a residual component of such noise will inevitable reside within the observations when clock errors are interpolated, and such noise will affect the resolution of the positioning results. In this paper, which is based on a twenty-one-week analysis of the atomic clock noise characteristics of numerous satellites, a new stochastic observation model that considers satellite clock interpolation errors is proposed. First, the systematic error of each satellite in the IGR clock product was extracted using a wavelet de-noising method to obtain the empirical characteristics of atomic clock noise within each clock product. Then, based on those empirical characteristics, a stochastic observation model was structured that considered the satellite clock interpolation errors. Subsequently, the IGR and IGS clock products at different time intervals were used for experimental validation. A verification using 179 stations worldwide from the IGS showed that, compared with the conventional model, the convergence times using the stochastic model proposed in this study were respectively shortened by 4.8% and 4.0% when the IGR and IGS 300-s-interval clock products were used and by 19.1% and 19.4% when the 900-s-interval clock products were used. Furthermore, the disturbances during the initial phase of the calculation were also effectively improved.

  4. Characterization of positional errors and their influence on micro four-point probe measurements on a 100 nm Ru film

    DEFF Research Database (Denmark)

    Kjær, Daniel; Hansen, Ole; Østerberg, Frederik Westergaard

    2015-01-01

    Thin-film sheet resistance measurements at high spatial resolution and on small pads are important and can be realized with micrometer-scale four-point probes. As a result of the small scale the measurements are affected by electrode position errors. We have characterized the electrode position...... errors in measurements on Ru thin film using an Au-coated 12-point probe. We show that the standard deviation of the static electrode position error is on the order of 5 nm, which significantly affects the results of single configuration measurements. Position-error-corrected dual......-configuration measurements, however, are shown to eliminate the effect of position errors to a level limited either by electrical measurement noise or dynamic position errors. We show that the probe contact points remain almost static on the surface during the measurements (measured on an atomic scale) with a standard...

  5. Analysis of the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery☆

    Science.gov (United States)

    Arba-Mosquera, Samuel; Aslanides, Ioannis M.

    2012-01-01

    Purpose To analyze the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery. Methods A comprehensive model, which directly considers eye movements, including saccades, vestibular, optokinetic, vergence, and miniature, as well as, eye-tracker acquisition rate, eye-tracker latency time, scanner positioning time, laser firing rate, and laser trigger delay have been developed. Results Eye-tracker acquisition rates below 100 Hz correspond to pulse positioning errors above 1.5 mm. Eye-tracker latency times to about 15 ms correspond to pulse positioning errors of up to 3.5 mm. Scanner positioning times to about 9 ms correspond to pulse positioning errors of up to 2 mm. Laser firing rates faster than eye-tracker acquisition rates basically duplicate pulse-positioning errors. Laser trigger delays to about 300 μs have minor to no impact on pulse-positioning errors. Conclusions The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.

  6. The Effect of Antenna Position Errors on Redundant-Baseline Calibration of HERA

    Science.gov (United States)

    Orosz, Naomi; Dillon, Joshua; Ewall-Wice, Aaron; Parsons, Aaron; HERA Collaboration

    2018-01-01

    HERA (the Hydrogen Epoch of Reionization Array) is a large, highly-redundant radio interferometer in South Africa currently being built out to 350 14-m dishes. Its mission is to probe large scale structure during and prior to the epoch of reionization using the 21 cm hyperfine transition of neutral hydrogen. The array is designed to be calibrated using redundant baselines of known lengths. However, the dishes can deviate from ideal positions, with errors on the order of a few centimeters. This potentially increases foreground contamination of the 21 cm power spectrum in the cleanest part of Fourier space. The calibration algorithm treats groups of baselines that should be redundant, but are not due to position errors, as if they actually are. Accurate, precise calibration is critical because the foreground signals are 100,000 times stronger than the reionization signal. We explain the origin of this effect and discuss weighting strategies to mitigate it.

  7. Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correction

    International Nuclear Information System (INIS)

    Kapanen, Mika; Laaksomaa, Marko; Skyttä, Tanja; Haltamo, Mikko; Pehkonen, Jani; Lehtonen, Turkka; Kellokumpu-Lehtinen, Pirkko-Liisa; Hyödynmaa, Simo

    2016-01-01

    Residual position errors of the lymph node (LN) surrogates and humeral head (HH) were determined for 2 different arm fixation devices in radiotherapy (RT) of breast cancer: a standard wrist-hold (WH) and a house-made rod-hold (RH). The effect of arm position correction (APC) based on setup images was also investigated. A total of 113 consecutive patients with early-stage breast cancer with LN irradiation were retrospectively analyzed (53 and 60 using the WH and RH, respectively). Residual position errors of the LN surrogates (Th1-2 and clavicle) and the HH were investigated to compare the 2 fixation devices. The position errors and setup margins were determined before and after the APC to investigate the efficacy of the APC in the treatment situation. A threshold of 5 mm was used for the residual errors of the clavicle and Th1-2 to perform the APC, and a threshold of 7 mm was used for the HH. The setup margins were calculated with the van Herk formula. Irradiated volumes of the HH were determined from RT treatment plans. With the WH and the RH, setup margins up to 8.1 and 6.7 mm should be used for the LN surrogates, and margins up to 4.6 and 3.6 mm should be used to spare the HH, respectively, without the APC. After the APC, the margins of the LN surrogates were equal to or less than 7.5/6.0 mm with the WH/RH, but margins up to 4.2/2.9 mm were required for the HH. The APC was needed at least once with both the devices for approximately 60% of the patients. With the RH, irradiated volume of the HH was approximately 2 times more than with the WH, without any dose constraints. Use of the RH together with the APC resulted in minimal residual position errors and setup margins for all the investigated bony landmarks. Based on the obtained results, we prefer the house-made RH. However, more attention should be given to minimize the irradiation of the HH with the RH than with the WH.

  8. Performance monitoring and error significance in patients with obsessive-compulsive disorder.

    Science.gov (United States)

    Endrass, Tanja; Schuermann, Beate; Kaufmann, Christan; Spielberg, Rüdiger; Kniesche, Rainer; Kathmann, Norbert

    2010-05-01

    Performance monitoring has been consistently found to be overactive in obsessive-compulsive disorder (OCD). The present study examines whether performance monitoring in OCD is adjusted with error significance. Therefore, errors in a flanker task were followed by neutral (standard condition) or punishment feedbacks (punishment condition). In the standard condition patients had significantly larger error-related negativity (ERN) and correct-related negativity (CRN) ampliudes than controls. But, in the punishment condition groups did not differ in ERN and CRN amplitudes. While healthy controls showed an amplitude enhancement between standard and punishment condition, OCD patients showed no variation. In contrast, group differences were not found for the error positivity (Pe): both groups had larger Pe amplitudes in the punishment condition. Results confirm earlier findings of overactive error monitoring in OCD. The absence of a variation with error significance might indicate that OCD patients are unable to down-regulate their monitoring activity according to external requirements. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Error Analysis System for Spacecraft Navigation Using the Global Positioning System (GPS)

    Science.gov (United States)

    Truong, S. H.; Hart, R. C.; Hartman, K. R.; Tomcsik, T. L.; Searl, J. E.; Bernstein, A.

    1997-01-01

    The Flight Dynamics Division (FDD) at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) is currently developing improved space-navigation filtering algorithms to use the Global Positioning System (GPS) for autonomous real-time onboard orbit determination. In connection with a GPS technology demonstration on the Small Satellite Technology Initiative (SSTI)/Lewis spacecraft, FDD analysts and programmers have teamed with the GSFC Guidance, Navigation, and Control Branch to develop the GPS Enhanced Orbit Determination Experiment (GEODE) system. The GEODE system consists of a Kalman filter operating as a navigation tool for estimating the position, velocity, and additional states required to accurately navigate the orbiting Lewis spacecraft by using astrodynamic modeling and GPS measurements from the receiver. A parallel effort at the FDD is the development of a GPS Error Analysis System (GEAS) that will be used to analyze and improve navigation filtering algorithms during development phases and during in-flight calibration. For GEAS, the Kalman filter theory is extended to estimate the errors in position, velocity, and other error states of interest. The estimation of errors in physical variables at regular intervals will allow the time, cause, and effect of navigation system weaknesses to be identified. In addition, by modeling a sufficient set of navigation system errors, a system failure that causes an observed error anomaly can be traced and accounted for. The GEAS software is formulated using Object Oriented Design (OOD) techniques implemented in the C++ programming language on a Sun SPARC workstation. The Phase 1 of this effort is the development of a basic system to be used to evaluate navigation algorithms implemented in the GEODE system. This paper presents the GEAS mathematical methodology, systems and operations concepts, and software design and implementation. Results from the use of the basic system to evaluate

  10. Influence of Marker Movement Errors on Measuring 3 Dimentional Scapular Position and Orientation

    Directory of Open Access Journals (Sweden)

    Afsoun Nodehi-Moghaddam

    2003-12-01

    Full Text Available Objective: Scapulothoracic muscles weakness or fatique can result in abnormal scapular positioning and compromising scapulo-humeral rhythm and shoulder dysfunction .The scapula moves in a -3 Dimentional fashion so the use of 2-Dimentional Techniques cannot fully capture scapular motion . One of approaches to positioining markers of kinematic systems is to mount each marker directly on the skin generally over a bony anatomical landmarks . Howerer skin movement and Motion of underlying bony structures are not Necessaritly identical and substantial errors may be introduced in the description of bone movement when using skin –mounted markers. evaluation of Influence of marker movement errors on 3-Dimentional scapular position and orientation. Materials & Methods: 10 Healthy subjects with a mean age 30.50 participated in the study . They were tested in three sessions A 3-dimentiional electro mechanical digitizer was used to measure scapular position and orientation measures were obtained while arm placed at the side of the body and elevated 45٫90٫120 and full Rang of motion in the scapular plane . At each test positions six bony landmarks were palpated and skin markers were mounted on them . This procedure repeated in the second test session in third session Removal of markers was not performed through obtaining entire Range of motion after mounting the markers . Results: The intraclass correlation coefficients (ICC for scapulor variables were higher (0.92-0.84 when markers were replaced and re-mounted on bony landmarks with Increasing the angle of elevation. Conclusion: our findings suggested significant markers movement error on measuring the upward Rotation and posterior tilt angle of scapula.

  11. Precise positioning of patients for radiation therapy

    International Nuclear Information System (INIS)

    Verhey, L.J.; Goitein, M.; McNulty, P.; Munzenrider, J.E.; Suit, H.D.

    1982-01-01

    A number of immobilization schemes which permit precise daily positioning of patients for radiation therapy are discussed. Pretreatment and post-treatment radiographs have been taken with the patient in the treatment position and analyzed to determine the amount of intratreatment movement. Studies of patients in the supine, seated and decubitus positions indicate mean movements of less than 1 mm with a standard deviation of less than 1 mm. Patients immobilized in the seated position with a bite block and a mask have a mean movement of about 0.5 mm +/- 0.3 mm (s.d.), and patients immobilized in the supine position with their necks hyperextended for submental therapy evidence a mean movement of about 1.4 mm +/- 0.9 mm (s.d.). With the exception of those used for the decubitus position, the immobilization devices are simply fabricated out of thermoplastic casting materials readily available from orthopedic supply houses. A study of day-to-day reproducibility of patient position using laser alignment and pretreatment radiographs for final verification of position indicates that the initial laser alignment can be used to position a patient within 2.2 mm +/- 1.4 mm (s.d.) of the intended position. These results indicate that rigid immobilization devices can improve the precision of radiotherapy, which would be advantageous with respect to both tumor and normal tissue coverage in certain situations

  12. Medication Administration Errors Involving Paediatric In-Patients in a ...

    African Journals Online (AJOL)

    The drug mostly associated with error was gentamicin with 29 errors (1.2 %). Conclusion: During the study, a high frequency of error was observed. There is a need to modify the way information is handled and shared by professionals as wrong time error was the most implicated error. Attention should also be given to IV ...

  13. [Positioning errors of CT common rail technique in intensity-modulated radiotherapy for nasopharyngeal carcinoma].

    Science.gov (United States)

    Tian, Fei; Xu, Zihai; Mo, Li; Zhu, Chaohua; Chen, Chaomin

    2012-11-01

    To evaluate the value of CT common rail technique for application in intensity-modulated radiotherapy for nasopharyngeal carcinoma (NPC). Twenty-seven NPC patients underwent Somatom CT scans using the Siemens CTVision system prior to the commencement of the radiotherapy sessions. The acquired CT images were registered with the planning CT images using the matching function of the system to obtain the linear set-up errors of 3 directions, namely X (left to right), Y (superior to inferior), and Z (anterior to posterior). The errors were then corrected online on the moving couch. The 27 NPC patients underwent a total of 110 CT scans and the displacement deviations of the X, Y and Z directions were -0.16∓1.68 mm, 0.25∓1.66 mm, and 0.33∓1.09 mm, respectively. CT common rail technique can accurately and rapidly measure the space error between the posture and the target area to improve the set-up precision of intensity-modulated radiotherapy for NPC.

  14. Development of a Simple Radioactive marker System to Reduce Positioning Errors in Radiation Treatment

    International Nuclear Information System (INIS)

    William H. Miller; Dr. Jatinder Palta

    2007-01-01

    The objective of this research is to implement an inexpensive, quick and simple monitor that provides an accurate indication of proper patient position during the treatment of cancer by external beam X-ray radiation and also checks for any significant changes in patient anatomy. It is believed that this system will significantly reduce the treatment margin, provide an additional, independent quality assurance check of positioning accuracy prior to all treatments and reduce the probability of misadministration of therapeutic dose

  15. Effect of cooling on thixotropic position-sense error in human biceps muscle.

    Science.gov (United States)

    Sekihara, Chikara; Izumizaki, Masahiko; Yasuda, Tomohiro; Nakajima, Takayuki; Atsumi, Takashi; Homma, Ikuo

    2007-06-01

    Muscle temperature affects muscle thixotropy. However, it is unclear whether changes in muscle temperature affect thixotropic position-sense errors. We studied the effect of cooling on thixotropic position-sense errors induced by short-length muscle contraction (hold-short conditioning) in the biceps of 12 healthy men. After hold-short conditioning of the right biceps muscle in a cooled (5.0 degrees C) or control (36.5 degrees C) environment, subjects perceived greater extension of the conditioned forearm at 5.0 degrees C. The angle differences between the two forearms following hold-short conditioning of the right biceps muscle in normal or cooled conditions were significantly different (-3.335 +/- 1.680 degrees at 36.5 degrees C vs. -5.317 +/- 1.096 degrees at 5.0 degrees C; P=0.043). Induction of a tonic vibration reflex in the biceps muscle elicited involuntary forearm elevation, and the angular velocities of the elevation differed significantly between arms conditioned in normal and cooled environments (1.583 +/- 0.326 degrees /s at 36.5 degrees C vs. 3.100 +/- 0.555 degrees /s at 5.0 degrees C, P=0.0039). Thus, a cooled environment impairs a muscle's ability to provide positional information, potentially leading to poor muscle performance.

  16. Improving patient safety in radiotherapy through error reporting and analysis

    International Nuclear Information System (INIS)

    Findlay, Ú.; Best, H.; Ottrey, M.

    2016-01-01

    Aim: To improve patient safety in radiotherapy (RT) through the analysis and publication of radiotherapy errors and near misses (RTE). Materials and methods: RTE are submitted on a voluntary basis by NHS RT departments throughout the UK to the National Reporting and Learning System (NRLS) or directly to Public Health England (PHE). RTE are analysed by PHE staff using frequency trend analysis based on the classification and pathway coding from Towards Safer Radiotherapy (TSRT). PHE in conjunction with the Patient Safety in Radiotherapy Steering Group publish learning from these events, on a triannual and summarised on a biennial basis, so their occurrence might be mitigated. Results: Since the introduction of this initiative in 2010, over 30,000 (RTE) reports have been submitted. The number of RTE reported in each biennial cycle has grown, ranging from 680 (2010) to 12,691 (2016) RTE. The vast majority of the RTE reported are lower level events, thus not affecting the outcome of patient care. Of the level 1 and 2 incidents reported, it is known the majority of them affected only one fraction of a course of treatment. This means that corrective action could be taken over the remaining treatment fractions so the incident did not have a significant impact on the patient or the outcome of their treatment. Analysis of the RTE reports demonstrates that generation of error is not confined to one professional group or to any particular point in the pathway. It also indicates that the pattern of errors is replicated across service providers in the UK. Conclusion: Use of the terminology, classification and coding of TSRT, together with implementation of the national voluntary reporting system described within this report, allows clinical departments to compare their local analysis to the national picture. Further opportunities to improve learning from this dataset must be exploited through development of the analysis and development of proactive risk management strategies

  17. Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Soo Man [Dept. of Radiation Oncology, Kosin University Gospel Hospital, Busan (Korea, Republic of)

    2008-09-15

    To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2-3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head and Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head and Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  18. Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Kang, Soo Man

    2008-01-01

    To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2-3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head and Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head and Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  19. Influence of chronic neck pain on cervical joint position error (JPE): Comparison between young and elderly subjects.

    Science.gov (United States)

    Alahmari, Khalid A; Reddy, Ravi Shankar; Silvian, Paul; Ahmad, Irshad; Nagaraj, Venkat; Mahtab, Mohammad

    2017-11-06

    Evaluation of cervical joint position sense in subjects with chronic neck pain has gained importance in recent times. Different authors have established increased joint position error (JPE) in subjects with acute neck pain. However, there is a paucity of studies to establish the influence of chronic neck pain on cervical JPE. The objective of the study was to understand the influence of chronic neck pain on cervical JPE, and to examine the differences in cervical JPE between young and elderly subjects with chronic neck pain. Forty-two chronic neck pain patients (mean age 47.4) were compared for cervical JPE with 42 age-matched healthy subjects (mean age 47.8), using a digital inclinometer. The cervical JPE were measured in flexion, extension, and rotation in right and left movement directions. The comparison of JPE showed significantly larger errors in subjects with chronic neck pain when compared to healthy subjects (ppain revealed no significant differences (P> 0.05) in cervical JPE. Cervical joint position sense is impaired in subjects with chronic neck pain.

  20. Square-Wave Voltage Injection Algorithm for PMSM Position Sensorless Control With High Robustness to Voltage Errors

    DEFF Research Database (Denmark)

    Ni, Ronggang; Xu, Dianguo; Blaabjerg, Frede

    2017-01-01

    relationship with the magnetic field distortion. Position estimation errors caused by higher order harmonic inductances and voltage harmonics generated by the SVPWM are also discussed. Both simulations and experiments are carried out based on a commercial PMSM to verify the superiority of the proposed method......Rotor position estimated with high-frequency (HF) voltage injection methods can be distorted by voltage errors due to inverter nonlinearities, motor resistance, and rotational voltage drops, etc. This paper proposes an improved HF square-wave voltage injection algorithm, which is robust to voltage...... errors without any compensations meanwhile has less fluctuation in the position estimation error. The average position estimation error is investigated based on the analysis of phase harmonic inductances, and deduced in the form of the phase shift of the second-order harmonic inductances to derive its...

  1. Patient positioning and ventilator-associated pneumonia.

    Science.gov (United States)

    Hess, Dean R

    2005-07-01

    Rotational beds, prone position, and semi-recumbent position have been proposed as procedures to prevent ventilator-associated pneumonia (VAP). Rotational therapy uses a special bed designed to turn continuously, or nearly continuously, the patient from side to side; specific designs include kinetic therapy and continuous lateral rotation therapy. A meta-analysis of studies evaluating the effect of rotational bed therapy shows a decrease in the risk of pneumonia but no effect on mortality. Two studies reported a lower risk of VAP in patients placed in a prone position, with no effect on mortality. Studies using radiolabeled enteral feeding solutions in mechanically ventilated patients have reported that aspiration of gastric contents occurs to a greater degree when patients are in the supine position, compared with the semirecumbent position. One study reported a lower rate of VAP in patients randomized to semi-recumbent compared to supine position. Although each of the techniques discussed in this paper has been shown to reduce the risk of VAP, none has been shown to affect mortality. The available evidence suggests that semi-recumbent position should be used routinely, rotational therapy should be considered in selected patients, and prone position should not be used as a technique to reduce the risk of VAP.

  2. The frequency of diagnostic errors in radiologic reports depends on the patient's age

    International Nuclear Information System (INIS)

    Diaz, Sandra; Ekberg, Olle

    2010-01-01

    Background: Patients who undergo treatment may suffer preventable medical errors. Some of these errors are due to diagnostic imaging procedures. Purpose: To compare the frequency of diagnostic errors in different age groups in an urban European population. Material and Methods: A total of 19 129 reported radiologic examinations were included. During a 6-month period, the analyzed age groups were: children (aged 0-9 years), adults (40-49 years), and elderly (86-95 years). Results: The frequency of radiologic examinations per year was 0.3 in children, 0.6 in adults, and 1.1 in elderly. Significant errors were significantly more frequent in the elderly (1.7%) and children (1.4%) compared with adults (0.8%). There were 60 false-positive reports and 232 false-negative reports. Most errors were made by staff radiologists after hours when they reported on examinations outside their area of expertise. Conclusion: Diagnostic errors are more frequent in children and the elderly compared with middle-aged adults

  3. Avoiding Errors in the Management of Pediatric Polytrauma Patients.

    Science.gov (United States)

    Chin, Kenneth; Abzug, Joshua; Bae, Donald S; Horn, Bernard D; Herman, Martin; Eberson, Craig P

    2016-01-01

    Management of pediatric polytrauma patients is one of the most difficult challenges for orthopaedic surgeons. Multisystem injuries frequently include complex orthopaedic surgical problems that require intervention. The physiology and anatomy of children and adolescent trauma patients differ from the physiology and anatomy of an adult trauma patient, which alters the types of injuries sustained and the ideal methods for management. Errors of pediatric polytrauma care are included in two broad categories: missed injuries and inadequate fracture treatment. Diagnoses may be missed most frequently because of a surgeon's inability to reliably assess patients who have traumatic brain injuries and painful distracting injuries. Cervical spine injuries are particularly difficult to identify in a child with polytrauma and may have devastating consequences. In children who have multiple injuries, the stabilization of long bone fractures with pediatric fixation techniques, such as elastic nails and other implants, allows for easier care and more rapid mobilization compared with cast treatments. Adolescent polytrauma patients who are approaching skeletal maturity, however, are ideally treated as adults to avoid complications, such as loss of fixation, and to speed rehabilitation.

  4. Rotational patient setup errors in IGRT with XVI system in Elekta Synergy and their clinical relevance

    International Nuclear Information System (INIS)

    Madhusudhana Sresty, N.V.N.; Muralidhar, K.R.; Raju, A.K.; Sha, R.L.; Ramanjappa

    2008-01-01

    The goal of Image Guided Radiotherapy (IGRT) is to improve the accuracy of treatment delivery. In this technique, it is possible to get volumetric images of patient anatomy before delivery of treatment.XVI( release 3.5) system in Elekta Synergy linear accelerator (Elekta,Crawley,UK) has the potential to ensure that, the relative positions of the target volume is same as in the treatment plan. It involves acquiring planar images produced by a kilo Voltage cone beam rotating about the patient in the treatment position. After 3 dimensional match between reference and localization images, the system gives rotational errors also along with translational shifts. One can easily perform translational shifts with treatment couch. But rotational shifts cannot be performed. Most of the studies dealt with translational shifts only. Few studies reported regarding rotational errors. It is found that in the treatment of elongated targets, even small rotational errors can show difference in results. The main objectives of this study is 1) To verify the magnitude of rotational errors in different clinical sites observed and to compare with the other reports. 2) To find its clinical relevance 3) To find difference in rotational shift results with improper selection of kV collimator

  5. Errors in patient specimen collection: application of statistical process control.

    Science.gov (United States)

    Dzik, Walter Sunny; Beckman, Neil; Selleng, Kathleen; Heddle, Nancy; Szczepiorkowski, Zbigniew; Wendel, Silvano; Murphy, Michael

    2008-10-01

    Errors in the collection and labeling of blood samples for pretransfusion testing increase the risk of transfusion-associated patient morbidity and mortality. Statistical process control (SPC) is a recognized method to monitor the performance of a critical process. An easy-to-use SPC method was tested to determine its feasibility as a tool for monitoring quality in transfusion medicine. SPC control charts were adapted to a spreadsheet presentation. Data tabulating the frequency of mislabeled and miscollected blood samples from 10 hospitals in five countries from 2004 to 2006 were used to demonstrate the method. Control charts were produced to monitor process stability. The participating hospitals found the SPC spreadsheet very suitable to monitor the performance of the sample labeling and collection and applied SPC charts to suit their specific needs. One hospital monitored subcategories of sample error in detail. A large hospital monitored the number of wrong-blood-in-tube (WBIT) events. Four smaller-sized facilities, each following the same policy for sample collection, combined their data on WBIT samples into a single control chart. One hospital used the control chart to monitor the effect of an educational intervention. A simple SPC method is described that can monitor the process of sample collection and labeling in any hospital. SPC could be applied to other critical steps in the transfusion processes as a tool for biovigilance and could be used to develop regional or national performance standards for pretransfusion sample collection. A link is provided to download the spreadsheet for free.

  6. Verification of patient position and delivery of IMRT by electronic portal imaging

    International Nuclear Information System (INIS)

    Fielding, Andrew L.; Evans, Philip M.; Clark, Catharine H.

    2004-01-01

    Background and purpose: The purpose of the work presented in this paper was to determine whether patient positioning and delivery errors could be detected using electronic portal images of intensity modulated radiotherapy (IMRT). Patients and methods: We carried out a series of controlled experiments delivering an IMRT beam to a humanoid phantom using both the dynamic and multiple static field method of delivery. The beams were imaged, the images calibrated to remove the IMRT fluence variation and then compared with calibrated images of the reference beams without any delivery or position errors. The first set of experiments involved translating the position of the phantom both laterally and in a superior/inferior direction a distance of 1, 2, 5 and 10 mm. The phantom was also rotated 1 and 2 deg. For the second set of measurements the phantom position was kept fixed and delivery errors were introduced to the beam. The delivery errors took the form of leaf position and segment intensity errors. Results: The method was able to detect shifts in the phantom position of 1 mm, leaf position errors of 2 mm, and dosimetry errors of 10% on a single segment of a 15 segment IMRT step and shoot delivery (significantly less than 1% of the total dose). Conclusions: The results of this work have shown that the method of imaging the IMRT beam and calibrating the images to remove the intensity modulations could be a useful tool in verifying both the patient position and the delivery of the beam

  7. Positivity, discontinuity, finite resources, and nonzero error for arbitrarily varying quantum channels

    International Nuclear Information System (INIS)

    Boche, H.; Nötzel, J.

    2014-01-01

    This work is motivated by a quite general question: Under which circumstances are the capacities of information transmission systems continuous? The research is explicitly carried out on finite arbitrarily varying quantum channels (AVQCs). We give an explicit example that answers the recent question whether the transmission of messages over AVQCs can benefit from assistance by distribution of randomness between the legitimate sender and receiver in the affirmative. The specific class of channels introduced in that example is then extended to show that the unassisted capacity does have discontinuity points, while it is known that the randomness-assisted capacity is always continuous in the channel. We characterize the discontinuity points and prove that the unassisted capacity is always continuous around its positivity points. After having established shared randomness as an important resource, we quantify the interplay between the distribution of finite amounts of randomness between the legitimate sender and receiver, the (nonzero) probability of a decoding error with respect to the average error criterion and the number of messages that can be sent over a finite number of channel uses. We relate our results to the entanglement transmission capacities of finite AVQCs, where the role of shared randomness is not yet well understood, and give a new sufficient criterion for the entanglement transmission capacity with randomness assistance to vanish

  8. Mobility and Position Error Analysis of a Complex Planar Mechanism with Redundant Constraints

    Science.gov (United States)

    Sun, Qipeng; Li, Gangyan

    2018-03-01

    Nowadays mechanisms with redundant constraints have been created and attracted much attention for their merits. The mechanism of the redundant constraints in a mechanical system is analyzed in this paper. A analysis method of Planar Linkage with a repetitive structure is proposed to get the number and type of constraints. According to the difference of applications and constraint characteristics, the redundant constraints are divided into the theoretical planar redundant constraints and the space-planar redundant constraints. And the calculation formula for the number of redundant constraints and type of judging method are carried out. And a complex mechanism with redundant constraints is analyzed of the influence about redundant constraints on mechanical performance. With the combination of theoretical derivation and simulation research, a mechanism analysis method is put forward about the position error of complex mechanism with redundant constraints. It points out the direction on how to eliminate or reduce the influence of redundant constraints.

  9. Detection of treatment setup errors between two CT scans for patients with head and neck cancer

    International Nuclear Information System (INIS)

    Ezzell, Leah C.; Hansen, Eric K.; Quivey, Jeanne M.; Xia Ping

    2007-01-01

    methods used for verifying patient positioning may misinterpret rotational shifts as translational shifts, and our study demonstrated that rotational errors may be significant in the treatment of head and neck cancer

  10. Mucocutaneous disorders in Hiv positive patients

    Directory of Open Access Journals (Sweden)

    Kar H

    1996-01-01

    Full Text Available Twenty eight HIV positive patients were included in this study. They were evaluated for their mucocutaneous disorders, sexually transmitted diseases and other systemic disorders between 1994-95 in the department of Dermatology and STD Dr R M L Hospital of New Delhi. The heterosexual contact with commercial sex workers (CSWs was the most common route of HIV transmission. Chancroid, syphilis and genital warts were common STDs found in HIV positive patients. Oral thrush (67.9% was the commonest mucocutaneous disorder found in these patients followed by herpes zoster (25% and seborrhoeic dermatitis (21.4%. There was no unusual clinical presentation seen in mucocutaneous disorders and STDs.

  11. Frecuencia de errores de los pacientes con su medicación Frequency of medication errors by patients

    Directory of Open Access Journals (Sweden)

    José Joaquín Mira

    2012-02-01

    Full Text Available OBJETIVO: Analizar la frecuencia de errores de medicación que son cometidos e informados por los pacientes. MÉTODOS: Estudio descriptivo basado en encuestas telefónicas a una muestra aleatoria de pacientes adultos del nivel primario de salud del sistema público español. Respondieron un total de 1 247 pacientes (tasa de respuesta, 75%. El 63% eran mujeres y 29% eran mayores de 70 años. RESULTADOS: Mientras 37 pacientes (3%, IC 95%: 2-4 sufrieron complicaciones asociadas a la medicación en el curso del tratamiento, 241 (19,4%, IC 95%: 17-21 informaron haber cometido algún error con la medicación. Un menor tiempo de consulta (P OBJECTIVE: Analyze the frequency of medication errors committed and reported by patients. METHODS: Descriptive study based on a telephone survey of a random sample of adult patients from the primary care level of the Spanish public health care system. A total of 1 247 patients responded (75% response rate; 63% were women and 29% were older than 70 years. RESULTS: While 37 patients (3%, 95% CI: 2-4 experienced complications associated with medication in the course of treatment, 241 (19.4%, 95% CI: 17-21 reported having made some mistake with their medication. A shorter consultation time (P < 0.01 and a worse assessment of the information provided by the physician (P < 0.01 were associated with the fact that during pharmacy dispensing the patient was told that the prescribed treatment was not appropriate. CONCLUSIONS: In addition to the known risks of an adverse event due to a health intervention resulting from a system or practitioner error, there are risks associated with patient errors in the self-administration of medication. Patients who were unsatisfied with the information provided by the physician reported a greater number of errors.

  12. Identification errors in the blood transfusion laboratory: a still relevant issue for patient safety.

    Science.gov (United States)

    Lippi, Giuseppe; Plebani, Mario

    2011-04-01

    Remarkable technological advances and increased awareness have both contributed to decrease substantially the uncertainty of the analytical phase, so that the manually intensive preanalytical activities currently represent the leading sources of errors in laboratory and transfusion medicine. Among preanalytical errors, misidentification and mistransfusion are still regarded as a considerable problem, posing serious risks for patient health and carrying huge expenses for the healthcare system. As such, a reliable policy of risk management should be readily implemented, developing through a multifaceted approach to prevent or limit the adverse outcomes related to transfusion reactions from blood incompatibility. This strategy encompasses root cause analysis, compliance with accreditation requirements, strict adherence to standard operating procedures, guidelines and recommendations for specimen collection, use of positive identification devices, rejection of potentially misidentified specimens, informatics data entry, query host communication, automated systems for patient identification and sample labeling and an adequate and safe environment. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Reproducibility of patient positioning during routine radiotherapy, as assessed by an integrated megavoltage imaging system

    International Nuclear Information System (INIS)

    Gildersleve, J.; Dearnaley, D.P.; Evans, P.M.; Swindell, W.

    1995-01-01

    A portal imaging system has been used, in conjunction with a movie measurement technique to measure set-up errors for 15 patients treated with radiotherapy of the pelvis and for 12 patients treated with radiotherapy of the brain. The pelvic patients were treated without fixation devices and the brain patients were treated with individually-moulded plastic shells. As would be expected the brain treatments were found to be more accurate than the pelvic treatments. Results are presented in terms of five error types: random error from treatment to treatment, error between mean treatment position and simulation position, random simulation error, systematic simulator-to-treatment errors and total treatment error. For the brain patients the simulation-to-treatment error predominates and random treatment errors were small (95% ≤ 3 mm, 77% ≤ 1.5 mm). Vector components of the systematic simulation-to-treatment errors were 1-2 mm with maximal random simulation error of ± 5 mm (2 S.D.). There is much interest in the number of verification films necessary to evaluate treatment accuracy. These results indicate that one check film performed at the first treatment is likely to be sufficient for set-up evaluation. For the pelvis the random treatment error is larger (95% ≤ 4.5 mm, 87% ≤ 3 mm). The systematic simulation-to-treatment error is up to 3 mm and the maximal random simulation error is ± 6 mm (2 S.D.). Thus corrections made solely on the basis of a first day check film may not be sufficient for adequate set-up evaluation

  14. Cerebral perfusion imaging in HIV positive patients

    International Nuclear Information System (INIS)

    Kundley, Kshama; Chowdhury, D.; Lele, V.R.; Lele, R.D.

    1998-01-01

    Full text: Twelve human immunodeficiency virus (HIV) positive patients were studied by SPECT cerebral perfusion imaging 1 hour post injection of 15 mCi of 99m Tc-ECD under ideal conditions with a triple head gamma camera (Prism 3000 X P LEUHR), fanbeam collimators followed by Folstein Mini Mental Status Examination (FMMSE) and AIDS dementia complex (ADC) staging on the same day. All 12 patients were male, in the age range of 23-45 y (mean 31 y). The infected status was diagnosed by ELISA (10 patients) or Western blot (5 patients). The interval between diagnosis and imaging ranged from 1 month - 35 months (mean 15.3 months). Two patients were alcoholic and 2 were smokers. None of them had CNS disorder clinically. ADC staging and FMMSE could be performed in 4 patients. Two patients were normal (stage 0) and 2 were subclinical (stage 0.5) on ADC staging. FMMSE revealed normal or near normal status (mean score 35; maximum score 36). Cerebral perfusion images were interpreted simultaneously by 3 observers blind towards history and examination using semi-quantitative and quantitative methods by consensus. It revealed multiple areas of hypoperfusion, viz. temporal (11 patients (91 %), parietal 10 patients (83%), frontal 9 patients (75%, pre and post central gyrus 7 patients (58%), occipital 6 patients (50%) cingulate gyrus and cerebellum 5 patients (41%) and thalamic in 2 patients (16%). Hyper perfusion in caudate nuclei was noted in 10 patients (83%). The study reveals presence of multiple perfusion abnormalities on cerebral perfusion imaging in HIV positive patients who have normal/near normal mental status suggesting precedence of perfusion abnormality over clinically apparent mental deficit

  15. Analysis of the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery

    Directory of Open Access Journals (Sweden)

    Samuel Arba-Mosquera

    2012-01-01

    Conclusions: The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.

  16. A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

    Directory of Open Access Journals (Sweden)

    Payam Samadi Miandoab

    2016-12-01

    Full Text Available Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion of dynamic organs, a phantom employs non-uniform rational B-splines (NURBS-based Cardiac-Torso method with spline-based model to generate 4D computed tomography (CT images. First, to generate all the possible roto-translation positions, the 4D CT images were imported to Medical Image Data Examiner (AMIDE. Then, for automatic, real time verification of geometrical setup, an artificial neural network (ANN was proposed to estimate patient displacement, using training sets. Moreover, three external motion markers were synchronized with a patient couch position as reference points. In addition, the technique was validated through simulated activities by using reference 4D CT data acquired from five patients. Results The results indicated that patient geometrical set-up is highly depended on the comprehensiveness of training set. By using ANN model, the average patient setup error in XCAT phantom was reduced from 17.26 mm to 0.50 mm. In addition, in the five real patients, these average errors were decreased from 18.26 mm to 1.48 mm various breathing phases ranging from inhalation to exhalation were taken into account for patient setup. Uncertainty error assessment and different setup errors were obtained from each respiration phase. Conclusion This study proposed a new method for alignment of patient setup error using ANN model. Additionally, our correlation model (ANN could estimate true patient position with less error.

  17. SU-E-T-114: Analysis of MLC Errors On Gamma Pass Rates for Patient-Specific and Conventional Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Sterling, D; Ehler, E [University of Minnesota, Minneapolis, MN (United States)

    2015-06-15

    Purpose: To evaluate whether a 3D patient-specific phantom is better able to detect known MLC errors in a clinically delivered treatment plan than conventional phantoms. 3D printing may make fabrication of such phantoms feasible. Methods: Two types of MLC errors were introduced into a clinically delivered, non-coplanar IMRT, partial brain treatment plan. First, uniformly distributed random errors of up to 3mm, 2mm, and 1mm were introduced into the MLC positions for each field. Second, systematic MLC-bank position errors of 5mm, 3.5mm, and 2mm due to simulated effects of gantry and MLC sag were introduced. The original plan was recalculated with these errors on the original CT dataset as well as cylindrical and planar IMRT QA phantoms. The original dataset was considered to be a perfect 3D patient-specific phantom. The phantoms were considered to be ideal 3D dosimetry systems with no resolution limitations. Results: Passing rates for Gamma Index (3%/3mm and no dose threshold) were calculated on the 3D phantom, cylindrical phantom, and both on a composite and field-by-field basis for the planar phantom. Pass rates for 5mm systematic and 3mm random error were 86.0%, 89.6%, 98% and 98.3% respectively. For 3.5mm systematic and 2mm random error the pass rates were 94.7%, 96.2%, 99.2% and 99.2% respectively. For 2mm systematic error with 1mm random error the pass rates were 99.9%, 100%, 100% and 100% respectively. Conclusion: A 3D phantom with the patient anatomy is able to discern errors, both severe and subtle, that are not seen using conventional phantoms. Therefore, 3D phantoms may be beneficial for commissioning new treatment machines and modalities, patient-specific QA and end-to-end testing.

  18. SU-E-T-114: Analysis of MLC Errors On Gamma Pass Rates for Patient-Specific and Conventional Phantoms

    International Nuclear Information System (INIS)

    Sterling, D; Ehler, E

    2015-01-01

    Purpose: To evaluate whether a 3D patient-specific phantom is better able to detect known MLC errors in a clinically delivered treatment plan than conventional phantoms. 3D printing may make fabrication of such phantoms feasible. Methods: Two types of MLC errors were introduced into a clinically delivered, non-coplanar IMRT, partial brain treatment plan. First, uniformly distributed random errors of up to 3mm, 2mm, and 1mm were introduced into the MLC positions for each field. Second, systematic MLC-bank position errors of 5mm, 3.5mm, and 2mm due to simulated effects of gantry and MLC sag were introduced. The original plan was recalculated with these errors on the original CT dataset as well as cylindrical and planar IMRT QA phantoms. The original dataset was considered to be a perfect 3D patient-specific phantom. The phantoms were considered to be ideal 3D dosimetry systems with no resolution limitations. Results: Passing rates for Gamma Index (3%/3mm and no dose threshold) were calculated on the 3D phantom, cylindrical phantom, and both on a composite and field-by-field basis for the planar phantom. Pass rates for 5mm systematic and 3mm random error were 86.0%, 89.6%, 98% and 98.3% respectively. For 3.5mm systematic and 2mm random error the pass rates were 94.7%, 96.2%, 99.2% and 99.2% respectively. For 2mm systematic error with 1mm random error the pass rates were 99.9%, 100%, 100% and 100% respectively. Conclusion: A 3D phantom with the patient anatomy is able to discern errors, both severe and subtle, that are not seen using conventional phantoms. Therefore, 3D phantoms may be beneficial for commissioning new treatment machines and modalities, patient-specific QA and end-to-end testing

  19. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E.; Zhen Heming; Tome, Wolfgang A. [Canis Lupus LLC and Department of Human Oncology, University of Wisconsin, Merrimac, Wisconsin 53561 (United States); Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 (United States); Departments of Human Oncology, Medical Physics, and Biomedical Engineering, University of Wisconsin, Madison, Wisconsin 53792 (United States)

    2011-02-15

    Purpose: The purpose of this work is to determine the statistical correlation between per-beam, planar IMRT QA passing rates and several clinically relevant, anatomy-based dose errors for per-patient IMRT QA. The intent is to assess the predictive power of a common conventional IMRT QA performance metric, the Gamma passing rate per beam. Methods: Ninety-six unique data sets were created by inducing four types of dose errors in 24 clinical head and neck IMRT plans, each planned with 6 MV Varian 120-leaf MLC linear accelerators using a commercial treatment planning system and step-and-shoot delivery. The error-free beams/plans were used as ''simulated measurements'' (for generating the IMRT QA dose planes and the anatomy dose metrics) to compare to the corresponding data calculated by the error-induced plans. The degree of the induced errors was tuned to mimic IMRT QA passing rates that are commonly achieved using conventional methods. Results: Analysis of clinical metrics (parotid mean doses, spinal cord max and D1cc, CTV D95, and larynx mean) vs IMRT QA Gamma analysis (3%/3 mm, 2/2, 1/1) showed that in all cases, there were only weak to moderate correlations (range of Pearson's r-values: -0.295 to 0.653). Moreover, the moderate correlations actually had positive Pearson's r-values (i.e., clinically relevant metric differences increased with increasing IMRT QA passing rate), indicating that some of the largest anatomy-based dose differences occurred in the cases of high IMRT QA passing rates, which may be called ''false negatives.'' The results also show numerous instances of false positives or cases where low IMRT QA passing rates do not imply large errors in anatomy dose metrics. In none of the cases was there correlation consistent with high predictive power of planar IMRT passing rates, i.e., in none of the cases did high IMRT QA Gamma passing rates predict low errors in anatomy dose metrics or vice versa

  20. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors

    International Nuclear Information System (INIS)

    Nelms, Benjamin E.; Zhen Heming; Tome, Wolfgang A.

    2011-01-01

    Purpose: The purpose of this work is to determine the statistical correlation between per-beam, planar IMRT QA passing rates and several clinically relevant, anatomy-based dose errors for per-patient IMRT QA. The intent is to assess the predictive power of a common conventional IMRT QA performance metric, the Gamma passing rate per beam. Methods: Ninety-six unique data sets were created by inducing four types of dose errors in 24 clinical head and neck IMRT plans, each planned with 6 MV Varian 120-leaf MLC linear accelerators using a commercial treatment planning system and step-and-shoot delivery. The error-free beams/plans were used as ''simulated measurements'' (for generating the IMRT QA dose planes and the anatomy dose metrics) to compare to the corresponding data calculated by the error-induced plans. The degree of the induced errors was tuned to mimic IMRT QA passing rates that are commonly achieved using conventional methods. Results: Analysis of clinical metrics (parotid mean doses, spinal cord max and D1cc, CTV D95, and larynx mean) vs IMRT QA Gamma analysis (3%/3 mm, 2/2, 1/1) showed that in all cases, there were only weak to moderate correlations (range of Pearson's r-values: -0.295 to 0.653). Moreover, the moderate correlations actually had positive Pearson's r-values (i.e., clinically relevant metric differences increased with increasing IMRT QA passing rate), indicating that some of the largest anatomy-based dose differences occurred in the cases of high IMRT QA passing rates, which may be called ''false negatives.'' The results also show numerous instances of false positives or cases where low IMRT QA passing rates do not imply large errors in anatomy dose metrics. In none of the cases was there correlation consistent with high predictive power of planar IMRT passing rates, i.e., in none of the cases did high IMRT QA Gamma passing rates predict low errors in anatomy dose metrics or vice versa. Conclusions: There is a lack of correlation between

  1. A study of the positioning errors of head and neck in the process of intensity modulation radiated therapy of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lin Chengguang; Lin Liuwen; Liu Bingti; Liu Xiaomao; Li Guowen

    2011-01-01

    Objective: To investigate the positioning errors of head and neck during intensity-modulated radiation therapy of nasopharyngeal carcinoma. Methods: Nineteen patients with middle-advanced nasopharyngeal carcinoma (T 2-4 N 1-3 M 0 ), treated by intensity-modulated radiation therapy, underwent repeated CT during their 6-week treatment course. All the patients were immobilized by head-neck-shoulder thermoplastic mask. We evaluated their anatomic landmark coordinated in a total of 66 repeated CT data sets and respective x, y, z shifts relative to their position in the planning CT. Results: The positioning error of the neck was 2.44 mm ± 2.24 mm, 2.05 mm ± 1.42 mm, 1.83 mm ± 1.53 mm in x, y, z respectively. And that of the head was 1.05 mm ± 0.87 mm, 1.23 mm ± 1.05 mm, 1.17 mm ± 1.55 mm respectively. The positioning error between neck and head have respectively statistical difference (t=-6.58, -5.28, -3.42, P=0.000, 0.000, 0.001). The system error of the neck was 2.33, 1.67 and 1.56 higher than that of the head, respectively in left-right, vertical and head-foot directions; and the random error of neck was 2.57, 1.34 and 0.99 higher than that of head respectively. Conclusions: In the process of the intensity-modulated radiation therapy of nasopharyngeal carcinoma, with the immobilization by head-neck-shoulder thermoplastic mask, the positioning error of neck is higher than that of head. (authors)

  2. Investigations on uncertainties in patient positioning for prostate treatment with EPID

    International Nuclear Information System (INIS)

    Bakai, A.; Nuesslin, F.; Paulsen, F.; Plasswilm, L.; Bamberg, M.

    2002-01-01

    Background: Conformal radiotherapy techniques as used in prostate treatment allow to spare normal tissue by conforming the radiation fields to the shape of the planning target volume (PTV). To be able to fully utilize the advantages of these techniques correct patient positioning is an important prerequisite. This study employing an electronic portal imaging device (EPID) investigated the positioning uncertainties that occur in the pelvic region for different patient positioning devices. Patients and Methods: 15 patients with prostate cancer were irradiated with or without rectal balloon/pelvic mask at a linear accelerator with multileaf collimator (MLC). For each patient multiple portal images were taken from different directions and compared to the digitally reconstructed radiographs (DRRs) of the treatment planning system and to simulation films (Table 1, Figure 1). Results: In spite of different positioning devices, all patients showed comparable total positioning uncertainties of 4.0 mm (lateral), 4.5 mm (cranio-caudal) and 1.7 mm (dorso-ventral). The lateral positioning error was reduced for the pelvic mask patients while the cranio-caudal error increased (Table 2, Figure 2). A systematic and a random component sum up to the total positioning error, and a good estimate of the magnitudes of the two is possible from six to eight portal images (Figure 3). Conclusions: With a small number of portal images it is possible to find out the systematic and random positioning error of a patient. Knowledge of the random error can be used to resize the treatment margin which is clinically relevant since this error differs greatly for different patients (Figure 4). Image analysis with EPID is convenient, yet has some problems. For example, one only gets indirect information on the movement of the ventral rectum wall. The successful operation of positioning devices, although, needs further improvement - especially if one focuses on IMRT. (orig.) [de

  3. Patient position matching between SPECT and CT

    International Nuclear Information System (INIS)

    Eubig, C.; Lodhi, L.M.; Trueblood, J.H.; Kingsbury, T.; Burke, G.; Flickenger, F.

    1990-01-01

    Since the authors had previously developed an ability for accurate repositioning of patients by means of video imaging of their external features, it was their purpose to determine if separate video systems placed in SPECT and CT rooms could be positioned and a calibration procedure for each modality developed to assure easy identification and acquisition of corresponding congruent axial image sections through the patient. A video frame grabber is used to acquire an image of the patient in one room and superimpose it on a similar image of the patient in the other room. A radioactive ruler visible at CT images obtained with a gamma camera computer, and a CT scout image are used to adjust the initial relative position of the video cameras and calibrate the acquisition parameters of both systems. The success of this alignment procedure was tested with a body phantom. The body phantom studies indicate that this method of positioning the patient and acquiring corresponding aligned CT and SPECT axial sections can be successful where internal organ shift between the acquisitions is minimal. This should lead to a reduction of the time and computer resources necessary to fuse or superimpose images of corresponding patient sections acquired with different modalities

  4. SU-F-J-208: Prompt Gamma Imaging-Based Prediction of Bragg Peak Position for Realistic Treatment Error Scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Y; Macq, B; Bondar, L [Universite catholique de Louvain, Louvain-la-Neuve (Belgium); Janssens, G [IBA, Louvain-la-Neuve (Belgium)

    2016-06-15

    Purpose: To quantify the accuracy in predicting the Bragg peak position using simulated in-room measurements of prompt gamma (PG) emissions for realistic treatment error scenarios that combine several sources of errors. Methods: Prompt gamma measurements by a knife-edge slit camera were simulated using an experimentally validated analytical simulation tool. Simulations were performed, for 143 treatment error scenarios, on an anthropomorphic phantom and a pencil beam scanning plan for nasal cavity. Three types of errors were considered: translation along each axis, rotation around each axis, and CT-calibration errors with magnitude ranging respectively, between −3 and 3 mm, −5 and 5 degrees, and between −5 and +5%. We investigated the correlation between the Bragg peak (BP) shift and the horizontal shift of PG profiles. The shifts were calculated between the planned (reference) position and the position by the error scenario. The prediction error for one spot was calculated as the absolute difference between the PG profile shift and the BP shift. Results: The PG shift was significantly and strongly correlated with the BP shift for 92% of the cases (p<0.0001, Pearson correlation coefficient R>0.8). Moderate but significant correlations were obtained for all cases that considered only CT-calibration errors and for 1 case that combined translation and CT-errors (p<0.0001, R ranged between 0.61 and 0.8). The average prediction errors for the simulated scenarios ranged between 0.08±0.07 and 1.67±1.3 mm (grand mean 0.66±0.76 mm). The prediction error was moderately correlated with the value of the BP shift (p=0, R=0.64). For the simulated scenarios the average BP shift ranged between −8±6.5 mm and 3±1.1 mm. Scenarios that considered combinations of the largest treatment errors were associated with large BP shifts. Conclusion: Simulations of in-room measurements demonstrate that prompt gamma profiles provide reliable estimation of the Bragg peak position for

  5. Impact of habitat-specific GPS positional error on detection of movement scales by first-passage time analysis.

    Directory of Open Access Journals (Sweden)

    David M Williams

    Full Text Available Advances in animal tracking technologies have reduced but not eliminated positional error. While aware of such inherent error, scientists often proceed with analyses that assume exact locations. The results of such analyses then represent one realization in a distribution of possible outcomes. Evaluating results within the context of that distribution can strengthen or weaken our confidence in conclusions drawn from the analysis in question. We evaluated the habitat-specific positional error of stationary GPS collars placed under a range of vegetation conditions that produced a gradient of canopy cover. We explored how variation of positional error in different vegetation cover types affects a researcher's ability to discern scales of movement in analyses of first-passage time for white-tailed deer (Odocoileus virginianus. We placed 11 GPS collars in 4 different vegetative canopy cover types classified as the proportion of cover above the collar (0-25%, 26-50%, 51-75%, and 76-100%. We simulated the effect of positional error on individual movement paths using cover-specific error distributions at each location. The different cover classes did not introduce any directional bias in positional observations (1 m≤mean≤6.51 m, 0.24≤p≤0.47, but the standard deviation of positional error of fixes increased significantly with increasing canopy cover class for the 0-25%, 26-50%, 51-75% classes (SD = 2.18 m, 3.07 m, and 4.61 m, respectively and then leveled off in the 76-100% cover class (SD = 4.43 m. We then added cover-specific positional errors to individual deer movement paths and conducted first-passage time analyses on the noisy and original paths. First-passage time analyses were robust to habitat-specific error in a forest-agriculture landscape. For deer in a fragmented forest-agriculture environment, and species that move across similar geographic extents, we suggest that first-passage time analysis is robust with regard to

  6. Errors in the calculation of new salary positions and performance premiums – 2017 MERIT exercise

    CERN Multimedia

    Staff Association

    2017-01-01

    Following the receipt of the letters dated May 12th announcing the qualification of their performance (MERIT 2017), and the notification of their salary slips for the month of May, several colleagues have come to us to enquire about the calculation of salary increases and performance premiums. After verification, the Staff Association has informed the Management, in a meeting of the Standing Concertation Committee on June 1st, about errors owing to rounding in the applied formulas. James Purvis, Head of HR department, has published in the CERN Bulletin dated July 18th an article, under the heading “Better precision (rounding)”, that gives a short explanation of these rounding effects. But we want to further bring you more precise explanations. Advancement On the salary slips for the month of May, the calculations of the advancement and new salary positions were done, by the services of administrative computing in the FAP department, on the basis of the salary, rounded to the nearest franc...

  7. Joint position sense error in people with neck pain: A systematic review.

    Science.gov (United States)

    de Vries, J; Ischebeck, B K; Voogt, L P; van der Geest, J N; Janssen, M; Frens, M A; Kleinrensink, G J

    2015-12-01

    Several studies in recent decades have examined the relationship between proprioceptive deficits and neck pain. However, there is no uniform conclusion on the relationship between the two. Clinically, proprioception is evaluated using the Joint Position Sense Error (JPSE), which reflects a person's ability to accurately return his head to a predefined target after a cervical movement. We focused to differentiate between JPSE in people with neck pain compared to healthy controls. Systematic review according to the PRISMA guidelines. Our data sources were Embase, Medline OvidSP, Web of Science, Cochrane Central, CINAHL and Pubmed Publisher. To be included, studies had to compare JPSE of the neck (O) in people with neck pain (P) with JPSE of the neck in healthy controls (C). Fourteen studies were included. Four studies reported that participants with traumatic neck pain had a significantly higher JPSE than healthy controls. Of the eight studies involving people with non-traumatic neck pain, four reported significant differences between the groups. The JPSE did not vary between neck-pain groups. Current literature shows the JPSE to be a relevant measure when it is used correctly. All studies which calculated the JPSE over at least six trials showed a significantly increased JPSE in the neck pain group. This strongly suggests that 'number of repetitions' is a major element in correctly performing the JPSE test. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Positioning performance analysis of the time sum of arrival algorithm with error features

    Science.gov (United States)

    Gong, Feng-xun; Ma, Yan-qiu

    2018-03-01

    The theoretical positioning accuracy of multilateration (MLAT) with the time difference of arrival (TDOA) algorithm is very high. However, there are some problems in practical applications. Here we analyze the location performance of the time sum of arrival (TSOA) algorithm from the root mean square error ( RMSE) and geometric dilution of precision (GDOP) in additive white Gaussian noise (AWGN) environment. The TSOA localization model is constructed. Using it, the distribution of location ambiguity region is presented with 4-base stations. And then, the location performance analysis is started from the 4-base stations with calculating the RMSE and GDOP variation. Subsequently, when the location parameters are changed in number of base stations, base station layout and so on, the performance changing patterns of the TSOA location algorithm are shown. So, the TSOA location characteristics and performance are revealed. From the RMSE and GDOP state changing trend, the anti-noise performance and robustness of the TSOA localization algorithm are proved. The TSOA anti-noise performance will be used for reducing the blind-zone and the false location rate of MLAT systems.

  9. Tuberculosis treatment among smear positive tuberculosis patients

    International Nuclear Information System (INIS)

    Munir, M.K.; Iqbal, R.; Shabbir, I.; Chaudhry, K

    2012-01-01

    Tuberculosis is a major health problem in many parts of the world. Delay in initiation of the treatment may result in prolonged infectious state, drug resistance, relapse and death. Objectives: To determine the factors responsible for not starting tuberculosis treatment among smear positive tuberculosis patients. Study type, settings and duration: This cross sectional study was done at Pakistan Medical Research Council TB Research Center, King Edward Medical University, Lahore, from fifth March 2010 to fifth December 2010. Patients and Methods: Fifty sputum smear positive patients of tuberculosis who did not register themselves in treatment register and presumably did not initiate anti tuberculosis treatment were contacted using telephone or traced by their home addresses. Once contact was established, they were inquired about the reasons for not starting tuberculosis treatment. Results: Of 50 patients 38(76%)belonged to the lower socio economic class and 12(24%) to the lower middle class. Fourteen patients (28%) were illiterate and 23(46%) had only 8 years of education. Of the 50 cases 41(82%) were taking treatment from traditional healers and 4% did not go back to the DOTS program. Physical condition of the patient, social, domestic and religious issues also played some role in default. Conclusions: Lack of health education and poverty were the main factors responsible for non compliance from treatment. Policy message: Sputum testing sites should have a paramedic who should educate the patients about the benefits of treatment and the dangers of default or partial treatment. (author)

  10. Dosimetric implications of inter- and intrafractional prostate positioning errors during tomotherapy : Comparison of gold marker-based registrations with native MVCT.

    Science.gov (United States)

    Wust, Peter; Joswig, Marc; Graf, Reinhold; Böhmer, Dirk; Beck, Marcus; Barelkowski, Thomasz; Budach, Volker; Ghadjar, Pirus

    2017-09-01

    For high-dose radiation therapy (RT) of prostate cancer, image-guided (IGRT) and intensity-modulated RT (IMRT) approaches are standard. Less is known regarding comparisons of different IGRT techniques and the resulting residual errors, as well as regarding their influences on dose distributions. A total of 58 patients who received tomotherapy-based RT up to 84 Gy for high-risk prostate cancer underwent IGRT based either on daily megavoltage CT (MVCT) alone (n = 43) or the additional use of gold markers (n = 15) under routine conditions. Planned Adaptive (Accuray Inc., Madison, WI, USA) software was used for elaborated offline analysis to quantify residual interfractional prostate positioning errors, along with systematic and random errors and the resulting safety margins after both IGRT approaches. Dosimetric parameters for clinical target volume (CTV) coverage and exposition of organs at risk (OAR) were also analyzed and compared. Interfractional as well as intrafractional displacements were determined. Particularly in the vertical direction, residual interfractional positioning errors were reduced using the gold marker-based approach, but dosimetric differences were moderate and the clinical relevance relatively small. Intrafractional prostate motion proved to be quite high, with displacements of 1-3 mm; however, these did not result in additional dosimetric impairments. Residual interfractional positioning errors were reduced using gold marker-based IGRT; however, this resulted in only slightly different final dose distributions. Therefore, daily MVCT-based IGRT without markers might be a valid alternative.

  11. Patient safety in the clinical laboratory: a longitudinal analysis of specimen identification errors.

    Science.gov (United States)

    Wagar, Elizabeth A; Tamashiro, Lorraine; Yasin, Bushra; Hilborne, Lee; Bruckner, David A

    2006-11-01

    Patient safety is an increasingly visible and important mission for clinical laboratories. Attention to improving processes related to patient identification and specimen labeling is being paid by accreditation and regulatory organizations because errors in these areas that jeopardize patient safety are common and avoidable through improvement in the total testing process. To assess patient identification and specimen labeling improvement after multiple implementation projects using longitudinal statistical tools. Specimen errors were categorized by a multidisciplinary health care team. Patient identification errors were grouped into 3 categories: (1) specimen/requisition mismatch, (2) unlabeled specimens, and (3) mislabeled specimens. Specimens with these types of identification errors were compared preimplementation and postimplementation for 3 patient safety projects: (1) reorganization of phlebotomy (4 months); (2) introduction of an electronic event reporting system (10 months); and (3) activation of an automated processing system (14 months) for a 24-month period, using trend analysis and Student t test statistics. Of 16,632 total specimen errors, mislabeled specimens, requisition mismatches, and unlabeled specimens represented 1.0%, 6.3%, and 4.6% of errors, respectively. Student t test showed a significant decrease in the most serious error, mislabeled specimens (P patient safety projects. Trend analysis demonstrated decreases in all 3 error types for 26 months. Applying performance-improvement strategies that focus longitudinally on specimen labeling errors can significantly reduce errors, therefore improving patient safety. This is an important area in which laboratory professionals, working in interdisciplinary teams, can improve safety and outcomes of care.

  12. SU-E-P-36: Evaluation of MLC Positioning Errors in Dynamic IMRT Treatments by Analyzing Dynalog Files

    International Nuclear Information System (INIS)

    Olasolo, J; Pellejero, S; Gracia, M; Gallardo, N; Martin, M; Lozares, S; Maneru, F; Bragado, L; Miquelez, S; Rubio, A

    2015-01-01

    Purpose: To assess the accuracy of MLC positioning in Varian linear accelerator, in dynamic IMRT technique, from the analysis of dynalog files generated by the MLC controller. Methods: In Clinac accelerators (pre-TrueBeam technology), control system has an approximately 50ms delay (one control cycle time). Then, the system compares the measured position to the planned position corresponding to the next control cycle. As it has been confirmed by Varian technical support, this effect causes that measured positions appear in dynalogs one cycle out of phase with respect to the planned positions. Around 9000 dynalogs have been analyzed, coming from the three linear accelerators of our center (one Trilogy and two Clinac 21EX) equipped with a Millennium 120 MLC. In order to compare our results to recent publications, leaf positioning errors (RMS and 95th percentile) are calculated with and without delay effect. Dynalogs have been analyzed using a in-house Matlab software. Results: The RMS errors were 0.341, 0.339 and 0.348mm for each Linac; being the average error 0.343 mm. The 95th percentiles of the error were 0.617, 0.607 and 0.625; with an average of 0.617mm. A recent multi-institution study carried out by Kerns et al. found a mean leaf RMS error of 0.32mm and a 95th percentile error value of 0.64mm.Without delay effect, mean leaf RMS errors obtained were 0.040, 0.042 and 0.038mm for each treatment machine; being the average 0.040mm. The 95th percentile error values obtained were 0.057, 0.058 and 0.054 mm, with an average of 0.056mm. Conclusion: Results obtained for the mean leaf RMS error and the mean 95th percentile were consistent with the multi-institution study. Calculated error statistics with delay effect are significantly larger due to the speed proportional and systematic leaf offset. Consequently it is proposed to correct this effect in dynalogs analysis to determine the MLC performance

  13. Antiretroviral medication prescribing errors are common with hospitalization of HIV-infected patients.

    Science.gov (United States)

    Commers, Tessa; Swindells, Susan; Sayles, Harlan; Gross, Alan E; Devetten, Marcel; Sandkovsky, Uriel

    2014-01-01

    Errors in prescribing antiretroviral therapy (ART) often occur with the hospitalization of HIV-infected patients. The rapid identification and prevention of errors may reduce patient harm and healthcare-associated costs. A retrospective review of hospitalized HIV-infected patients was carried out between 1 January 2009 and 31 December 2011. Errors were documented as omission, underdose, overdose, duplicate therapy, incorrect scheduling and/or incorrect therapy. The time to error correction was recorded. Relative risks (RRs) were computed to evaluate patient characteristics and error rates. A total of 289 medication errors were identified in 146/416 admissions (35%). The most common was drug omission (69%). At an error rate of 31%, nucleoside reverse transcriptase inhibitors were associated with an increased risk of error when compared with protease inhibitors (RR 1.32; 95% CI 1.04-1.69) and co-formulated drugs (RR 1.59; 95% CI 1.19-2.09). Of the errors, 31% were corrected within the first 24 h, but over half (55%) were never remedied. Admissions with an omission error were 7.4 times more likely to have all errors corrected within 24 h than were admissions without an omission. Drug interactions with ART were detected on 51 occasions. For the study population (n = 177), an increased risk of admission error was observed for black (43%) compared with white (28%) individuals (RR 1.53; 95% CI 1.16-2.03) but no significant differences were observed between white patients and other minorities or between men and women. Errors in inpatient ART were common, and the majority were never detected. The most common errors involved omission of medication, and nucleoside reverse transcriptase inhibitors had the highest rate of prescribing error. Interventions to prevent and correct errors are urgently needed.

  14. SU-E-P-21: Impact of MLC Position Errors On Simultaneous Integrated Boost Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chengqiang, L; Yin, Y; Chen, L [Shandong Cancer Hospital and Institute, 440 Jiyan Road, Jinan, 250117 (China)

    2015-06-15

    Purpose: To investigate the impact of MLC position errors on simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for patients with nasopharyngeal carcinoma. Methods: To compare the dosimetric differences between the simulated plans and the clinical plans, ten patients with locally advanced NPC treated with SIB-IMRT were enrolled in this study. All plans were calculated with an inverse planning system (Pinnacle3, Philips Medical System{sub )}. Random errors −2mm to 2mm{sub )},shift errors{sub (} 2mm,1mm and 0.5mm) and systematic extension/ contraction errors (±2mm, ±1mm and ±0.5mm) of the MLC leaf position were introduced respectively into the original plans to create the simulated plans. Dosimetry factors were compared between the original and the simulated plans. Results: The dosimetric impact of the random and system shift errors of MLC position was insignificant within 2mm, the maximum changes in D95% of PGTV,PTV1,PTV2 were-0.92±0.51%,1.00±0.24% and 0.62±0.17%, the maximum changes in the D0.1cc of spinal cord and brainstem were 1.90±2.80% and −1.78±1.42%, the maximum changes in the Dmean of parotids were1.36±1.23% and −2.25±2.04%.However,the impact of MLC extension or contraction errors was found significant. For 2mm leaf extension errors, the average changes in D95% of PGTV,PTV1,PTV2 were 4.31±0.67%,4.29±0.65% and 4.79±0.82%, the averaged value of the D0.1cc to spinal cord and brainstem were increased by 7.39±5.25% and 6.32±2.28%,the averaged value of the mean dose to left and right parotid were increased by 12.75±2.02%,13.39±2.17% respectively. Conclusion: The dosimetric effect was insignificant for random MLC leaf position errors up to 2mm. There was a high sensitivity to dose distribution for MLC extension or contraction errors.We should pay attention to the anatomic changes in target organs and anatomical structures during the course,individual radiotherapy was recommended to ensure adaptive doses.

  15. The Impact of a Patient Safety Program on Medical Error Reporting

    Science.gov (United States)

    2005-05-01

    307 The Impact of a Patient Safety Program on Medical Error Reporting Donald R. Woolever Abstract Background: In response to the occurrence of...a sentinel event—a medical error with serious consequences—Eglin U.S. Air Force (USAF) Regional Hospital developed and implemented a patient safety...communication, teamwork, and reporting. Objective: To determine the impact of a patient safety program on patterns of medical error reporting. Methods: This

  16. Errors in measuring transverse and energy jitter by beam position monitors

    Energy Technology Data Exchange (ETDEWEB)

    Balandin, V.; Decking, W.; Golubeva, N.

    2010-02-15

    The problem of errors, arising due to finite BPMresolution, in the difference orbit parameters, which are found as a least squares fit to the BPM data, is one of the standard and important problems of accelerator physics. Even so for the case of transversely uncoupled motion the covariance matrix of reconstruction errors can be calculated ''by hand'', the direct usage of obtained solution, as a tool for designing of a ''good measurement system'', does not look to be fairly straightforward. It seems that a better understanding of the nature of the problem is still desirable. We make a step in this direction introducing dynamic into this problem, which at the first glance seems to be static. We consider a virtual beam consisting of virtual particles obtained as a result of application of reconstruction procedure to ''all possible values'' of BPM reading errors. This beam propagates along the beam line according to the same rules as any real beam and has all beam dynamical characteristics, such as emittances, energy spread, dispersions, betatron functions and etc. All these values become the properties of the BPM measurement system. One can compare two BPM systems comparing their error emittances and rms error energy spreads, or, for a given measurement system, one can achieve needed balance between coordinate and momentum reconstruction errors by matching the error betatron functions in the point of interest to the desired values. (orig.)

  17. Errors in measuring transverse and energy jitter by beam position monitors

    International Nuclear Information System (INIS)

    Balandin, V.; Decking, W.; Golubeva, N.

    2010-02-01

    The problem of errors, arising due to finite BPMresolution, in the difference orbit parameters, which are found as a least squares fit to the BPM data, is one of the standard and important problems of accelerator physics. Even so for the case of transversely uncoupled motion the covariance matrix of reconstruction errors can be calculated ''by hand'', the direct usage of obtained solution, as a tool for designing of a ''good measurement system'', does not look to be fairly straightforward. It seems that a better understanding of the nature of the problem is still desirable. We make a step in this direction introducing dynamic into this problem, which at the first glance seems to be static. We consider a virtual beam consisting of virtual particles obtained as a result of application of reconstruction procedure to ''all possible values'' of BPM reading errors. This beam propagates along the beam line according to the same rules as any real beam and has all beam dynamical characteristics, such as emittances, energy spread, dispersions, betatron functions and etc. All these values become the properties of the BPM measurement system. One can compare two BPM systems comparing their error emittances and rms error energy spreads, or, for a given measurement system, one can achieve needed balance between coordinate and momentum reconstruction errors by matching the error betatron functions in the point of interest to the desired values. (orig.)

  18. Comparison of community and hospital pharmacists' attitudes and behaviors on medication error disclosure to the patient: A pilot study.

    Science.gov (United States)

    Kim, ChungYun; Mazan, Jennifer L; Quiñones-Boex, Ana C

    To determine pharmacists' attitudes and behaviors on medication errors and their disclosure and to compare community and hospital pharmacists on such views. An online questionnaire was developed from previous studies on physicians' disclosure of errors. Questionnaire items included demographics, environment, personal experiences, and attitudes on medication errors and the disclosure process. An invitation to participate along with the link to the questionnaire was electronically distributed to members of two Illinois pharmacy associations. A follow-up reminder was sent 4 weeks after the original message. Data were collected for 3 months, and statistical analyses were performed with the use of IBM SPSS version 22.0. The overall response rate was 23.3% (n = 422). The average employed respondent was a 51-year-old white woman with a BS Pharmacy degree working in a hospital pharmacy as a clinical staff member. Regardless of practice settings, pharmacist respondents agreed that medication errors were inevitable and that a disclosure process is necessary. Respondents from community and hospital settings were further analyzed to assess any differences. Community pharmacist respondents were more likely to agree that medication errors were inevitable and that pharmacists should address the patient's emotions when disclosing an error. Community pharmacist respondents were also more likely to agree that the health care professional most closely involved with the error should disclose the error to the patient and thought that it was the pharmacists' responsibility to disclose the error. Hospital pharmacist respondents were more likely to agree that it was important to include all details in a disclosure process and more likely to disagree on putting a "positive spin" on the event. Regardless of practice setting, responding pharmacists generally agreed that errors should be disclosed to patients. There were, however, significant differences in their attitudes and behaviors

  19. Error or "act of God"? A study of patients' and operating room team members' perceptions of error definition, reporting, and disclosure.

    Science.gov (United States)

    Espin, Sherry; Levinson, Wendy; Regehr, Glenn; Baker, G Ross; Lingard, Lorelei

    2006-01-01

    Calls abound for a culture change in health care to improve patient safety. However, effective change cannot proceed without a clear understanding of perceptions and beliefs about error. In this study, we describe and compare operative team members' and patients' perceptions of error, reporting of error, and disclosure of error. Thirty-nine interviews of team members (9 surgeons, 9 nurses, 10 anesthesiologists) and patients (11) were conducted at 2 teaching hospitals using 4 scenarios as prompts. Transcribed responses to open questions were analyzed by 2 researchers for recurrent themes using the grounded-theory method. Yes/no answers were compared across groups using chi-square analyses. Team members and patients agreed on what constitutes an error. Deviation from standards and negative outcome were emphasized as definitive features. Patients and nurse professionals differed significantly in their perception of whether errors should be reported. Nurses were willing to report only events within their disciplinary scope of practice. Although most patients strongly advocated full disclosure of errors (what happened and how), team members preferred to disclose only what happened. When patients did support partial disclosure, their rationales varied from that of team members. Both operative teams and patients define error in terms of breaking the rules and the concept of "no harm no foul." These concepts pose challenges for treating errors as system failures. A strong culture of individualism pervades nurses' perception of error reporting, suggesting that interventions are needed to foster collective responsibility and a constructive approach to error identification.

  20. Catching errors with patient-specific pretreatment machine log file analysis.

    Science.gov (United States)

    Rangaraj, Dharanipathy; Zhu, Mingyao; Yang, Deshan; Palaniswaamy, Geethpriya; Yaddanapudi, Sridhar; Wooten, Omar H; Brame, Scott; Mutic, Sasa

    2013-01-01

    A robust, efficient, and reliable quality assurance (QA) process is highly desired for modern external beam radiation therapy treatments. Here, we report the results of a semiautomatic, pretreatment, patient-specific QA process based on dynamic machine log file analysis clinically implemented for intensity modulated radiation therapy (IMRT) treatments delivered by high energy linear accelerators (Varian 2100/2300 EX, Trilogy, iX-D, Varian Medical Systems Inc, Palo Alto, CA). The multileaf collimator machine (MLC) log files are called Dynalog by Varian. Using an in-house developed computer program called "Dynalog QA," we automatically compare the beam delivery parameters in the log files that are generated during pretreatment point dose verification measurements, with the treatment plan to determine any discrepancies in IMRT deliveries. Fluence maps are constructed and compared between the delivered and planned beams. Since clinical introduction in June 2009, 912 machine log file analyses QA were performed by the end of 2010. Among these, 14 errors causing dosimetric deviation were detected and required further investigation and intervention. These errors were the result of human operating mistakes, flawed treatment planning, and data modification during plan file transfer. Minor errors were also reported in 174 other log file analyses, some of which stemmed from false positives and unreliable results; the origins of these are discussed herein. It has been demonstrated that the machine log file analysis is a robust, efficient, and reliable QA process capable of detecting errors originating from human mistakes, flawed planning, and data transfer problems. The possibility of detecting these errors is low using point and planar dosimetric measurements. Copyright © 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  1. Medication Errors in Patients with Enteral Feeding Tubes in the Intensive Care Unit.

    Science.gov (United States)

    Sohrevardi, Seyed Mojtaba; Jarahzadeh, Mohammad Hossein; Mirzaei, Ehsan; Mirjalili, Mahtabalsadat; Tafti, Arefeh Dehghani; Heydari, Behrooz

    2017-01-01

    Most patients admitted to Intensive Care Units (ICU) have problems in using oral medication or ingesting solid forms of drugs. Selecting the most suitable dosage form in such patients is a challenge. The current study was conducted to assess the frequency and types of errors of oral medication administration in patients with enteral feeding tubes or suffering swallowing problems. A cross-sectional study was performed in the ICU of Shahid Sadoughi Hospital, Yazd, Iran. Patients were assessed for the incidence and types of medication errors occurring in the process of preparation and administration of oral medicines. Ninety-four patients were involved in this study and 10,250 administrations were observed. Totally, 4753 errors occurred among the studied patients. The most commonly used drugs were pantoprazole tablet, piracetam syrup, and losartan tablet. A total of 128 different types of drugs and nine different oral pharmaceutical preparations were prescribed for the patients. Forty-one (35.34%) out of 116 different solid drugs (except effervescent tablets and powders) could be substituted by liquid or injectable forms. The most common error was the wrong time of administration. Errors of wrong dose preparation and administration accounted for 24.04% and 25.31% of all errors, respectively. In this study, at least three-fourth of the patients experienced medication errors. The occurrence of these errors can greatly impair the quality of the patients' pharmacotherapy, and more attention should be paid to this issue.

  2. Decisions to shoot in a weapon identification task: The influence of cultural stereotypes and perceived threat on false positive errors.

    Science.gov (United States)

    Fleming, Kevin K; Bandy, Carole L; Kimble, Matthew O

    2010-01-01

    The decision to shoot a gun engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC), where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and electroencephalogram (EEG) activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of Middle-Eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERNs were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERNs, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of Middle-Eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to Middle-Eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance.

  3. SU-G-BRB-03: Assessing the Sensitivity and False Positive Rate of the Integrated Quality Monitor (IQM) Large Area Ion Chamber to MLC Positioning Errors

    Energy Technology Data Exchange (ETDEWEB)

    Boehnke, E McKenzie; DeMarco, J; Steers, J; Fraass, B [Cedars-Sinai Medical Center, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To examine both the IQM’s sensitivity and false positive rate to varying MLC errors. By balancing these two characteristics, an optimal tolerance value can be derived. Methods: An un-modified SBRT Liver IMRT plan containing 7 fields was randomly selected as a representative clinical case. The active MLC positions for all fields were perturbed randomly from a square distribution of varying width (±1mm to ±5mm). These unmodified and modified plans were measured multiple times each by the IQM (a large area ion chamber mounted to a TrueBeam linac head). Measurements were analyzed relative to the initial, unmodified measurement. IQM readings are analyzed as a function of control points. In order to examine sensitivity to errors along a field’s delivery, each measured field was divided into 5 groups of control points, and the maximum error in each group was recorded. Since the plans have known errors, we compared how well the IQM is able to differentiate between unmodified and error plans. ROC curves and logistic regression were used to analyze this, independent of thresholds. Results: A likelihood-ratio Chi-square test showed that the IQM could significantly predict whether a plan had MLC errors, with the exception of the beginning and ending control points. Upon further examination, we determined there was ramp-up occurring at the beginning of delivery. Once the linac AFC was tuned, the subsequent measurements (relative to a new baseline) showed significant (p <0.005) abilities to predict MLC errors. Using the area under the curve, we show the IQM’s ability to detect errors increases with increasing MLC error (Spearman’s Rho=0.8056, p<0.0001). The optimal IQM count thresholds from the ROC curves are ±3%, ±2%, and ±7% for the beginning, middle 3, and end segments, respectively. Conclusion: The IQM has proven to be able to detect not only MLC errors, but also differences in beam tuning (ramp-up). Partially supported by the Susan Scott Foundation.

  4. Nurses' Behaviors and Visual Scanning Patterns May Reduce Patient Identification Errors

    Science.gov (United States)

    Marquard, Jenna L.; Henneman, Philip L.; He, Ze; Jo, Junghee; Fisher, Donald L.; Henneman, Elizabeth A.

    2011-01-01

    Patient identification (ID) errors occurring during the medication administration process can be fatal. The aim of this study is to determine whether differences in nurses' behaviors and visual scanning patterns during the medication administration process influence their capacities to identify patient ID errors. Nurse participants (n = 20)…

  5. Transparency When Things Go Wrong: Physician Attitudes About Reporting Medical Errors to Patients, Peers, and Institutions.

    Science.gov (United States)

    Bell, Sigall K; White, Andrew A; Yi, Jean C; Yi-Frazier, Joyce P; Gallagher, Thomas H

    2017-12-01

    Transparent communication after medical error includes disclosing the mistake to the patient, discussing the event with colleagues, and reporting to the institution. Little is known about whether attitudes about these transparency practices are related. Understanding these relationships could inform educational and organizational strategies to promote transparency. We analyzed responses of 3038 US and Canadian physicians to a medical error communication survey. We used bivariate correlations, principal components analysis, and linear regression to determine whether and how physician attitudes about transparent communication with patients, peers, and the institution after error were related. Physician attitudes about disclosing errors to patients, peers, and institutions were correlated (all P's transparent communication with patients and peers/institution included female sex, US (vs Canadian) doctors, academic (vs private) practice, the belief that disclosure decreased likelihood of litigation, and the belief that system changes occur after error reporting. In addition, younger physicians, surgeons, and those with previous experience disclosing a serious error were more likely to agree with disclosure to patients. In comparison, doctors who believed that disclosure would decrease patient trust were less likely to agree with error disclosure to patients. Previous disclosure education was associated with attitudes supporting greater transparency with peers/institution. Physician attitudes about discussing errors with patients, colleagues, and institutions are related. Several predictors of transparency affect all 3 practices and are potentially modifiable by educational and institutional strategies.

  6. Relating faults in diagnostic reasoning with diagnostic errors and patient harm.

    NARCIS (Netherlands)

    Zwaan, L.; Thijs, A.; Wagner, C.; Wal, G. van der; Timmermans, D.R.M.

    2012-01-01

    Purpose: The relationship between faults in diagnostic reasoning, diagnostic errors, and patient harm has hardly been studied. This study examined suboptimal cognitive acts (SCAs; i.e., faults in diagnostic reasoning), related them to the occurrence of diagnostic errors and patient harm, and studied

  7. Evaluation of rotational set-up errors in patients with thoracic neoplasms

    International Nuclear Information System (INIS)

    Wang Yanyang; Fu Xiaolong; Xia Bing; Fan Min; Yang Huanjun; Ren Jun; Xu Zhiyong; Jiang Guoliang

    2010-01-01

    Objective: To assess the rotational set-up errors in patients with thoracic neoplasms. Methods: 224 kilovoltage cone-beam computed tomography (KVCBCT) scans from 20 thoracic tumor patients were evaluated retrospectively. All these patients were involved in the research of 'Evaluation of the residual set-up error for online kilovoltage cone-beam CT guided thoracic tumor radiation'. Rotational set-up errors, including pitch, roll and yaw, were calculated by 'aligning the KVCBCT with the planning CT, using the semi-automatic alignment method. Results: The average rotational set-up errors were -0.28 degree ±1.52 degree, 0.21 degree ± 0.91 degree and 0.27 degree ± 0.78 degree in the left-fight, superior-inferior and anterior-posterior axis, respectively. The maximal rotational errors of pitch, roll and yaw were 3.5 degree, 2.7 degree and 2.2 degree, respectively. After correction for translational set-up errors, no statistically significant changes in rotational error were observed. Conclusions: The rotational set-up errors in patients with thoracic neoplasms were all small in magnitude. Rotational errors may not change after the correction for translational set-up errors alone, which should be evaluated in a larger sample future. (authors)

  8. 2D position sensitive microstrip sensors with charge division along the strip Studies on the position measurement error

    CERN Document Server

    Bassignana, D; Fernandez, M; Jaramillo, R; Lozano, M; Munoz, F.J; Pellegrini, G; Quirion, D; Vila, I; Vitorero, F

    2013-01-01

    Position sensitivity in semiconductor detectors of ionizing radiation is usually achieved by the segmentation of the sensing diode junction in many small sensing elements read out separately as in the case of conventional microstrips and pixel detectors. Alternatively, position sensitivity can be obtained by splitting the ionization signal collected by one single electrode amongst more than one readout channel with the ratio of the collected charges depending on the position where the signal was primary generated. Following this later approach, we implemented the charge division method in a conventional microstrip detector to obtain position sensitivity along the strip. We manufactured a proofof-concept demonstrator where the conventional aluminum electrodes were replaced by slightly resistive electrodes made of strongly doped poly-crystalline silicon and being readout at both strip ends. Here, we partially summarize the laser characterization of this first proof-of-concept demonstrator with special emphasis ...

  9. Reducing patient identification errors related to glucose point-of-care testing

    Directory of Open Access Journals (Sweden)

    Gaurav Alreja

    2011-01-01

    Full Text Available Background: Patient identification (ID errors in point-of-care testing (POCT can cause test results to be transferred to the wrong patient′s chart or prevent results from being transmitted and reported. Despite the implementation of patient barcoding and ongoing operator training at our institution, patient ID errors still occur with glucose POCT. The aim of this study was to develop a solution to reduce identification errors with POCT. Materials and Methods: Glucose POCT was performed by approximately 2,400 clinical operators throughout our health system. Patients are identified by scanning in wristband barcodes or by manual data entry using portable glucose meters. Meters are docked to upload data to a database server which then transmits data to any medical record matching the financial number of the test result. With a new model, meters connect to an interface manager where the patient ID (a nine-digit account number is checked against patient registration data from admission, discharge, and transfer (ADT feeds and only matched results are transferred to the patient′s electronic medical record. With the new process, the patient ID is checked prior to testing, and testing is prevented until ID errors are resolved. Results: When averaged over a period of a month, ID errors were reduced to 3 errors/month (0.015% in comparison with 61.5 errors/month (0.319% before implementing the new meters. Conclusion: Patient ID errors may occur with glucose POCT despite patient barcoding. The verification of patient identification should ideally take place at the bedside before testing occurs so that the errors can be addressed in real time. The introduction of an ADT feed directly to glucose meters reduced patient ID errors in POCT.

  10. A false positive food chain error associated with a generic predator gut content ELISA

    Science.gov (United States)

    Conventional prey-specific gut content ELISA and PCR assays are useful for identifying predators of insect pests in nature. However, these assays are prone to yielding certain types of food chain errors. For instance, it is possible that prey remains can pass through the food chain as the result of ...

  11. Responsibility for reporting patient death due to hospital error in Japan when an error occurred at a referring institution.

    Science.gov (United States)

    Maeda, Shoichi; Starkey, Jay; Kamishiraki, Etsuko; Ikeda, Noriaki

    2013-12-01

    In Japan, physicians are required to report unexpected health care-associated patient deaths to the police. Patients needing to be transferred to another institution often have complex medical problems. If a medical error occurs, it may be either at the final or the referring institution. Some fear that liability will fall on the final institution regardless of where the error occurred or that the referring facility may oppose such reporting, leading to a failure to report to police or to recommend an autopsy. Little is known about the actual opinions of physicians and risk managers in this regard. The authors sent standardised, self-administered questionnaires to all hospitals in Japan that participate in the national general residency program. Most physicians and risk managers in Japan indicated that they would report a patient's death to the police where the patient has been transferred. Of those who indicated they would not report to the police, the majority still indicated they would recommend an autopsy

  12. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.

    2013-11-04

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.\\'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  13. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.; Saenz Agudelo, Pablo; Planes, Serge; Jones, Geoffrey P.; Berumen, Michael L.

    2013-01-01

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  14. UNDERSTANDING OR NURSES' REACTIONS TO ERRORS AND USING THIS UNDERSTANDING TO IMPROVE PATIENT SAFETY.

    Science.gov (United States)

    Taifoori, Ladan; Valiee, Sina

    2015-09-01

    The operating room can be home to many different types of nursing errors due to the invasiveness of OR procedures. The nurses' reactions towards errors can be a key factor in patient safety. This article is based on a study, with the aim of investigating nurses' reactions toward nursing errors and the various contributing and resulting factors, conducted at Kurdistan University of Medical Sciences in Sanandaj, Iran in 2014. The goal of the study was to determine how OR nurses' reacted to nursing errors with the goal of having this information used to improve patient safety. Research was conducted as a cross-sectional descriptive study. The participants were all nurses employed in the operating rooms of the teaching hospitals of Kurdistan University of Medical Sciences, which was selected by a consensus method (170 persons). The information was gathered through questionnaires that focused on demographic information, error definition, reasons for error occurrence, and emotional reactions for error occurrence, and emotional reactions toward the errors. 153 questionnaires were completed and analyzed by SPSS software version 16.0. "Not following sterile technique" (82.4 percent) was the most reported nursing error, "tiredness" (92.8 percent) was the most reported reason for the error occurrence, "being upset at having harmed the patient" (85.6 percent) was the most reported emotional reaction after error occurrence", with "decision making for a better approach to tasks the next time" (97.7 percent) as the most common goal and "paying more attention to details" (98 percent) was the most reported planned strategy for future improved outcomes. While healthcare facilities are focused on planning for the prevention and elimination of errors it was shown that nurses can also benefit from support after error occurrence. Their reactions, and coping strategies, need guidance and, with both individual and organizational support, can be a factor in improving patient safety.

  15. Skull registration for prone patient position using tracked ultrasound

    Science.gov (United States)

    Underwood, Grace; Ungi, Tamas; Baum, Zachary; Lasso, Andras; Kronreif, Gernot; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Tracked navigation has become prevalent in neurosurgery. Problems with registration of a patient and a preoperative image arise when the patient is in a prone position. Surfaces accessible to optical tracking on the back of the head are unreliable for registration. We investigated the accuracy of surface-based registration using points accessible through tracked ultrasound. Using ultrasound allows access to bone surfaces that are not available through optical tracking. Tracked ultrasound could eliminate the need to work (i) under the table for registration and (ii) adjust the tracker between surgery and registration. In addition, tracked ultrasound could provide a non-invasive method in comparison to an alternative method of registration involving screw implantation. METHODS: A phantom study was performed to test the feasibility of tracked ultrasound for registration. An initial registration was performed to partially align the pre-operative computer tomography data and skull phantom. The initial registration was performed by an anatomical landmark registration. Surface points accessible by tracked ultrasound were collected and used to perform an Iterative Closest Point Algorithm. RESULTS: When the surface registration was compared to a ground truth landmark registration, the average TRE was found to be 1.6+/-0.1mm and the average distance of points off the skull surface was 0.6+/-0.1mm. CONCLUSION: The use of tracked ultrasound is feasible for registration of patients in prone position and eliminates the need to perform registration under the table. The translational component of error found was minimal. Therefore, the amount of TRE in registration is due to a rotational component of error.

  16. Motivational processes from expectancy-value theory are associated with variability in the error positivity in young children.

    Science.gov (United States)

    Kim, Matthew H; Marulis, Loren M; Grammer, Jennie K; Morrison, Frederick J; Gehring, William J

    2017-03-01

    Motivational beliefs and values influence how children approach challenging activities. The current study explored motivational processes from an expectancy-value theory framework by studying children's mistakes and their responses to them by focusing on two event-related potential (ERP) components: the error-related negativity (ERN) and the error positivity (Pe). Motivation was assessed using a child-friendly challenge puzzle task and a brief interview measure prior to ERP testing. Data from 50 4- to 6-year-old children revealed that greater perceived competence beliefs were related to a larger Pe, whereas stronger intrinsic task value beliefs were associated with a smaller Pe. Motivation was unrelated to the ERN. Individual differences in early motivational processes may reflect electrophysiological activity related to conscious error awareness. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. The impact of sensor errors and building structures on particle filter-based inertial positioning

    DEFF Research Database (Denmark)

    Toftkjær, Thomas; Kjærgaard, Mikkel Baun

    2012-01-01

    Positioning systems that do not depend on in-building infrastructures are critical for enabling a range of applications within pervasive computing. Particle filter-based inertial positioning promises infrastructure-less positioning, but previous research has not provided an understanding of how t...

  18. Hand position-dependent modulation of errors in vibrotactile temporal order judgments

    DEFF Research Database (Denmark)

    Ritterband-Rosenbaum, Anina; Hermosillo, Robert; Kroliczak, Gregory

    2014-01-01

    this confounded information is processed in the brain is poorly understood. In the present set of experiments, we addressed this knowledge gap by using singlepulse transcranial magnetic stimulation (TMS) to disrupt processing in the right or left posterior parietal cortex (PPC) during a vibrotactile TOJ task...... with stimuli applied to the right and left index fingers. In the first experiment, participants held their hands in an uncrossed configuration, and we found that when the index finger contralateral to the site of TMS was stimulated first, there was a significant increase in TOJ errors. This increase did...... that these TMS-induced changes in TOJ errors were not due to a reduced ability to detect the timing of the vibrotactile stimuli. Taken together, these results demonstrate that both the right and left PPC contribute to the processing underlying vibrotactile TOJs by integrating vibrotactile information...

  19. [The effectiveness of error reporting promoting strategy on nurse's attitude, patient safety culture, intention to report and reporting rate].

    Science.gov (United States)

    Kim, Myoungsoo

    2010-04-01

    The purpose of this study was to examine the impact of strategies to promote reporting of errors on nurses' attitude to reporting errors, organizational culture related to patient safety, intention to report and reporting rate in hospital nurses. A nonequivalent control group non-synchronized design was used for this study. The program was developed and then administered to the experimental group for 12 weeks. Data were analyzed using descriptive analysis, X(2)-test, t-test, and ANCOVA with the SPSS 12.0 program. After the intervention, the experimental group showed significantly higher scores for nurses' attitude to reporting errors (experimental: 20.73 vs control: 20.52, F=5.483, p=.021) and reporting rate (experimental: 3.40 vs control: 1.33, F=1998.083, porganizational culture and intention to report. The study findings indicate that strategies that promote reporting of errors play an important role in producing positive attitudes to reporting errors and improving behavior of reporting. Further advanced strategies for reporting errors that can lead to improved patient safety should be developed and applied in a broad range of hospitals.

  20. Medical errors in hospitalized pediatric trauma patients with chronic health conditions

    Directory of Open Access Journals (Sweden)

    Xiaotong Liu

    2014-01-01

    Full Text Available Objective: This study compares medical errors in pediatric trauma patients with and without chronic conditions. Methods: The 2009 Kids’ Inpatient Database, which included 123,303 trauma discharges, was analyzed. Medical errors were identified by International Classification of Diseases, Ninth Revision, Clinical Modification diagnosis codes. The medical error rates per 100 discharges and per 1000 hospital days were calculated and compared between inpatients with and without chronic conditions. Results: Pediatric trauma patients with chronic conditions experienced a higher medical error rate compared with patients without chronic conditions: 4.04 (95% confidence interval: 3.75–4.33 versus 1.07 (95% confidence interval: 0.98–1.16 per 100 discharges. The rate of medical error differed by type of chronic condition. After controlling for confounding factors, the presence of a chronic condition increased the adjusted odds ratio of medical error by 37% if one chronic condition existed (adjusted odds ratio: 1.37, 95% confidence interval: 1.21–1.5, and 69% if more than one chronic condition existed (adjusted odds ratio: 1.69, 95% confidence interval: 1.48–1.53. In the adjusted model, length of stay had the strongest association with medical error, but the adjusted odds ratio for chronic conditions and medical error remained significantly elevated even when accounting for the length of stay, suggesting that medical complexity has a role in medical error. Higher adjusted odds ratios were seen in other subgroups. Conclusion: Chronic conditions are associated with significantly higher rate of medical errors in pediatric trauma patients. Future research should evaluate interventions or guidelines for reducing the risk of medical errors in pediatric trauma patients with chronic conditions.

  1. SU-F-T-381: Fast Calculation of Three-Dimensional Dose Considering MLC Leaf Positional Errors for VMAT Plans

    Energy Technology Data Exchange (ETDEWEB)

    Katsuta, Y [Takeda General Hospital, Aizuwakamatsu City, Fukushima (Japan); Tohoku University Graduate School of Medicine, Sendal, Miyagi (Japan); Kadoya, N; Jingu, K [Tohoku University Graduate School of Medicine, Sendal, Miyagi (Japan); Shimizu, E; Majima, K [Takeda General Hospital, Aizuwakamatsu City, Fukushima (Japan)

    2016-06-15

    Purpose: In this study, we developed a system to calculate three dimensional (3D) dose that reflects dosimetric error caused by leaf miscalibration for head and neck and prostate volumetric modulated arc therapy (VMAT) without additional treatment planning system calculation on real time. Methods: An original system called clarkson dose calculation based dosimetric error calculation to calculate dosimetric error caused by leaf miscalibration was developed by MATLAB (Math Works, Natick, MA). Our program, first, calculates point doses at isocenter for baseline and modified VMAT plan, which generated by inducing MLC errors that enlarged aperture size of 1.0 mm with clarkson dose calculation. Second, error incuced 3D dose was generated with transforming TPS baseline 3D dose using calculated point doses. Results: Mean computing time was less than 5 seconds. For seven head and neck and prostate plans, between our method and TPS calculated error incuced 3D dose, the 3D gamma passing rates (0.5%/2 mm, global) are 97.6±0.6% and 98.0±0.4%. The dose percentage change with dose volume histogram parameter of mean dose on target volume were 0.1±0.5% and 0.4±0.3%, and with generalized equivalent uniform dose on target volume were −0.2±0.5% and 0.2±0.3%. Conclusion: The erroneous 3D dose calculated by our method is useful to check dosimetric error caused by leaf miscalibration before pre treatment patient QA dosimetry checks.

  2. An Implementation of Error Minimization Position Estimate in Wireless Inertial Measurement Unit using Modification ZUPT

    Directory of Open Access Journals (Sweden)

    Adytia Darmawan

    2016-12-01

    Full Text Available Position estimation using WIMU (Wireless Inertial Measurement Unit is one of emerging technology in the field of indoor positioning systems. WIMU can detect movement and does not depend on GPS signals. The position is then estimated using a modified ZUPT (Zero Velocity Update method that was using Filter Magnitude Acceleration (FMA, Variance Magnitude Acceleration (VMA and Angular Rate (AR estimation. Performance of this method was justified on a six-legged robot navigation system. Experimental result shows that the combination of VMA-AR gives the best position estimation.

  3. Safety coaches in radiology: decreasing human error and minimizing patient harm

    Energy Technology Data Exchange (ETDEWEB)

    Dickerson, Julie M.; Adams, Janet M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States); Koch, Bernadette L.; Donnelly, Lane F. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Department of Pediatrics, Cincinnati, OH (United States); Goodfriend, Martha A. [Cincinnati Children' s Hospital Medical Center, Department of Quality Improvement, Cincinnati, OH (United States)

    2010-09-15

    Successful programs to improve patient safety require a component aimed at improving safety culture and environment, resulting in a reduced number of human errors that could lead to patient harm. Safety coaching provides peer accountability. It involves observing for safety behaviors and use of error prevention techniques and provides immediate feedback. For more than a decade, behavior-based safety coaching has been a successful strategy for reducing error within the context of occupational safety in industry. We describe the use of safety coaches in radiology. Safety coaches are an important component of our comprehensive patient safety program. (orig.)

  4. Safety coaches in radiology: decreasing human error and minimizing patient harm

    International Nuclear Information System (INIS)

    Dickerson, Julie M.; Adams, Janet M.; Koch, Bernadette L.; Donnelly, Lane F.; Goodfriend, Martha A.

    2010-01-01

    Successful programs to improve patient safety require a component aimed at improving safety culture and environment, resulting in a reduced number of human errors that could lead to patient harm. Safety coaching provides peer accountability. It involves observing for safety behaviors and use of error prevention techniques and provides immediate feedback. For more than a decade, behavior-based safety coaching has been a successful strategy for reducing error within the context of occupational safety in industry. We describe the use of safety coaches in radiology. Safety coaches are an important component of our comprehensive patient safety program. (orig.)

  5. Safety coaches in radiology: decreasing human error and minimizing patient harm.

    Science.gov (United States)

    Dickerson, Julie M; Koch, Bernadette L; Adams, Janet M; Goodfriend, Martha A; Donnelly, Lane F

    2010-09-01

    Successful programs to improve patient safety require a component aimed at improving safety culture and environment, resulting in a reduced number of human errors that could lead to patient harm. Safety coaching provides peer accountability. It involves observing for safety behaviors and use of error prevention techniques and provides immediate feedback. For more than a decade, behavior-based safety coaching has been a successful strategy for reducing error within the context of occupational safety in industry. We describe the use of safety coaches in radiology. Safety coaches are an important component of our comprehensive patient safety program.

  6. Pitch, roll, and yaw variations in patient positioning

    International Nuclear Information System (INIS)

    Kaiser, Adeel; Schultheiss, Timothy E.; Wong, Jeffrey Y.C.; Smith, David D.; Han, Chunhui; Vora, Nayana L.; Pezner, Richard D.; Chen Yijen; Radany, Eric H.

    2006-01-01

    Purpose: To use pretreatment megavoltage-computed tomography (MVCT) scans to evaluate positioning variations in pitch, roll, and yaw for patients treated with helical tomotherapy. Methods and Materials: Twenty prostate and 15 head-and-neck cancer patients were selected. Pretreatment MVCT scans were performed before every treatment fraction and automatically registered to planning kilovoltage CT (KVCT) scans by bony landmarks. Image registration data were used to adjust patient setups before treatment. Corrections for pitch, roll, and yaw were recorded after bone registration, and data from fractions 1-5 and 16-20 were used to analyze mean rotational corrections. Results: For prostate patients, the means and standard deviations (in degrees) for pitch, roll, and yaw corrections were -0.60 ± 1.42, 0.66 ± 1.22, and -0.33 ± 0.83. In head-and-neck patients, the means and standard deviations (in degrees) were -0.24 ± 1.19, -0.12 ± 1.53, and 0.25 ± 1.42 for pitch, roll, and yaw, respectively. No significant difference in rotational variations was observed between Weeks 1 and 4 of treatment. Head-and-neck patients had significantly smaller pitch variation, but significantly larger yaw variation, than prostate patients. No difference was found in roll corrections between the two groups. Overall, 96.6% of the rotational corrections were less than 4 deg. Conclusions: The initial rotational setup errors for prostate and head-and-neck patients were all small in magnitude, statistically significant, but did not vary considerably during the course of radiotherapy. The data are relevant to couch hardware design for correcting rotational setup variations. There should be no theoretical difference between these data and data collected using cone beam KVCT on conventional linacs

  7. Treating depression in HIV-positive patients affects adherence

    Directory of Open Access Journals (Sweden)

    M Y H Moosa

    2012-08-01

    Full Text Available Aim. To determine changes in adherence to antiretroviral therapy (ART in HIV-positive patients with depression, following treatment with an antidepressant or psychotherapy. Methods. The study was prospective, randomised and controlled. Consenting volunteers aged ≥18 years and stable on ART for ≥6 months were included in the study. Sociodemographic data were obtained, and a clinical diagnostic evaluation and the Hamilton Depression rating scale (HAMD were performed on all subjects at entry to and at the end of the study. Participants found to be depressed were randomly assigned antidepressant treatment (20 mg citalopram or interpersonal psychotherapy (IPT (5 sessions. Medication was dispensed at each visit and patients were asked to return all unused medication to determine ART adherence. The study was approved by the University of the Witwatersrand. Results. Sixty-two HIV-positive persons receiving ART participated; 30 were not depressed (control group and 32 were depressed (patient group. No significant differences in demographic characteristics existed between the control and patient groups. Mean ART adherence at the start of the study was 99.5% (standard error (SE ±0.46 and 92.1% (SE ±1.69 in the control and patients groups, respectively. Mean ART adherence at the end of the study changed marginally in the control group (99.7%; SE ±0.46 and increased significantly in the patient group (99.5%; SE± 0.13 (p>0.05. The mean ART adherence rate of patients who received pharmacotherapy increased from 92.8% to 99.5%, and of those who received psychotherapy increased from 91.1% to 99.6% (p>0.05. There was no significant association between the increased adherence in the patient group and baseline demographic and clinical characteristics, irrespective of antidepressant therapy or IPT (p>0.05. Conclusion. Successful treatment of depression with an antidepressant or psychotherapy was associated with improved ART adherence, independent of the type

  8. What Do Letter Migration Errors Reveal About Letter Position Coding in Visual Word Recognition?

    Science.gov (United States)

    Davis, Colin J.; Bowers, Jeffrey S.

    2004-01-01

    Dividing attention across multiple words occasionally results in misidentifications whereby letters apparently migrate between words. Previous studies have found that letter migrations preserve within-word letter position, which has been interpreted as support for position-specific letter coding. To investigate this issue, the authors used word…

  9. Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treatment plans

    International Nuclear Information System (INIS)

    Siebers, Jeffrey V.; Keall, Paul J.; Wu Qiuwen; Williamson, Jeffrey F.; Schmidt-Ullrich, Rupert K.

    2005-01-01

    Purpose: The purpose of this study is to determine dose delivery errors that could result from random and systematic setup errors for head-and-neck patients treated using the simultaneous integrated boost (SIB)-intensity-modulated radiation therapy (IMRT) technique. Methods and Materials: Twenty-four patients who participated in an intramural Phase I/II parotid-sparing IMRT dose-escalation protocol using the SIB treatment technique had their dose distributions reevaluated to assess the impact of random and systematic setup errors. The dosimetric effect of random setup error was simulated by convolving the two-dimensional fluence distribution of each beam with the random setup error probability density distribution. Random setup errors of σ = 1, 3, and 5 mm were simulated. Systematic setup errors were simulated by randomly shifting the patient isocenter along each of the three Cartesian axes, with each shift selected from a normal distribution. Systematic setup error distributions with Σ = 1.5 and 3.0 mm along each axis were simulated. Combined systematic and random setup errors were simulated for σ = Σ = 1.5 and 3.0 mm along each axis. For each dose calculation, the gross tumor volume (GTV) received by 98% of the volume (D 98 ), clinical target volume (CTV) D 90 , nodes D 90 , cord D 2 , and parotid D 50 and parotid mean dose were evaluated with respect to the plan used for treatment for the structure dose and for an effective planning target volume (PTV) with a 3-mm margin. Results: Simultaneous integrated boost-IMRT head-and-neck treatment plans were found to be less sensitive to random setup errors than to systematic setup errors. For random-only errors, errors exceeded 3% only when the random setup error σ exceeded 3 mm. Simulated systematic setup errors with Σ = 1.5 mm resulted in approximately 10% of plan having more than a 3% dose error, whereas a Σ = 3.0 mm resulted in half of the plans having more than a 3% dose error and 28% with a 5% dose error

  10. Dosimetric impact of systematic MLC positional errors on step and shoot IMRT for prostate cancer: a planning study

    International Nuclear Information System (INIS)

    Ung, N.M.; Harper, C.S.; Wee, L.

    2011-01-01

    Full text: The positional accuracy of multileaf collimators (MLC) is crucial in ensuring precise delivery of intensity-modulated radiotherapy (IMRT). The aim of this planning study was to investigate the dosimetric impact of systematic MLC positional errors on step and shoot IMRT of prostate cancer. A total of 12 perturbations of MLC leaf banks were introduced to six prostate IMRT treatment plans to simulate MLC systematic positional errors. Dose volume histograms (DVHs) were generated for the extraction of dose endpoint parameters. Plans were evaluated in terms of changes to the defined endpoint dose parameters, conformity index (CI) and healthy tissue avoidance (HTA) to planning target volume (PTV), rectum and bladder. Negative perturbations of MLC had been found to produce greater changes to endpoint dose parameters than positive perturbations of MLC (p 9 5 of -1.2 and 0.9% respectively. Negative and positive synchronised MLC perturbations of I mm in one direction resulted in median changes in D 9 5 of -2.3 and 1.8% respectively. Doses to rectum were generally more sensitive to systematic MLC en-ors compared to bladder (p < 0.01). Negative and positive synchronised MLC perturbations of I mm in one direction resulted in median changes in endpoint dose parameters of rectum and bladder from 1.0 to 2.5%. Maximum reduction of -4.4 and -7.3% were recorded for conformity index (CI) and healthy tissue avoidance (HT A) respectively due to synchronised MLC perturbation of 1 mm. MLC errors resulted in dosimetric changes in IMRT plans for prostate. (author)

  11. 21 CFR 868.6820 - Patient position support.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6820 Patient position support. (a) Identification. A patient position support is a device intended to maintain the position of an anesthetized... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Patient position support. 868.6820 Section 868...

  12. Mixing of multi-modal images for conformational radiotherapy: application to patient re positioning

    International Nuclear Information System (INIS)

    Vassal, P.

    1998-01-01

    This study shows a procedure of patient re positioning by comparative evaluation between the position of the patient and the theoretical expected position of the patient; the stagger between the two information gives the error of installation in translation and rotation. A correction is calculated and applied to the treatment environment (position and orientation of the patient, position and orientation of the irradiation source). The control system allows to determine the precise position of the tumor volume. The echography allows to determine the position of an organ.The surface captor is used to localize the tumors of the face or of the brain, with the respect to the face, the acquisition and the treatment of information take only few minutes. The X rays imager is applied for the localization of bones structures. (N.C.)

  13. Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients

    International Nuclear Information System (INIS)

    Letourneau, Daniel; Martinez, Alvaro A.; Lockman, David; Yan Di; Vargas, Carlos; Ivaldi, Giovanni; Wong, John

    2005-01-01

    Purpose: Kilovoltage cone-beam CT (CBCT) implemented on board a medical accelerator is available for image-guidance applications in our clinic. The objective of this work was to assess the magnitude and stability of the residual setup error associated with CBCT online-guided prostate cancer patient setup. Residual error pertains to the uncertainty in image registration, the limited mechanical accuracy, and the intrafraction motion during imaging and treatment. Methods and Materials: The residual error for CBCT online-guided correction was first determined in a phantom study. After online correction, the phantom residual error was determined by comparing megavoltage portal images acquired every 90 deg. to the corresponding digitally reconstructed radiographs. In the clinical study, 8 prostate cancer patients were implanted with three radiopaque markers made of high-winding coils. After positioning the patient using the skin marks, a CBCT scan was acquired and the setup error determined by fusing the coils on the CBCT and planning CT scans. The patient setup was then corrected by moving the couch accordingly. A second CBCT scan was acquired immediately after the correction to evaluate the residual target setup error. Intrafraction motion was evaluated by tracking the coils and the bony landmarks on kilovoltage radiographs acquired every 30 s between the two CBCT scans. Corrections based on soft-tissue registration were evaluated offline by aligning the prostate contours defined on both planning CT and CBCT images. Results: For ideal rigid phantoms, CBCT image-guided treatment can usually achieve setup accuracy of 1 mm or better. For the patients, after CBCT correction, the target setup error was reduced in almost all cases and was generally within ±1.5 mm. The image guidance process took 23-35 min, dictated by the computer speed and network configuration. The contribution of the intrafraction motion to the residual setup error was small, with a standard deviation of

  14. GPS Users Positioning Errors during Disturbed Near-Earth Space Conditions

    National Research Council Canada - National Science Library

    Afraimovich, E. L; Demyanov, V. V; Tatarinov, P. V; Astafieva, E. I; Zhivetiev, I. V

    2006-01-01

    .... (GPS Solutions, 2003, V7, N2, 109) showed, that during geomagnetic disturbances in the near space deterioration of GNSS operation quality is appeared and, as consequence, reduction of positioning accuracy and occurrence of failures...

  15. Error reduction in health care: a systems approach to improving patient safety

    National Research Council Canada - National Science Library

    Spath, Patrice

    2011-01-01

    .... The book pinpoints how to reduce and eliminate medical mistakes that threaten the health and safety of patients and teaches how to identify the root cause of medical errors, implement strategies...

  16. SU-E-T-132: Dosimetric Impact of Positioning Errors in Hypo-Fractionated Cranial Radiation Therapy Using Frameless Stereotactic BrainLAB System

    International Nuclear Information System (INIS)

    Keeling, V; Jin, H; Ali, I; Ahmad, S

    2014-01-01

    Purpose: To determine dosimetric impact of positioning errors in the stereotactic hypo-fractionated treatment of intracranial lesions using 3Dtransaltional and 3D-rotational corrections (6D) frameless BrainLAB ExacTrac X-Ray system. Methods: 20 cranial lesions, treated in 3 or 5 fractions, were selected. An infrared (IR) optical positioning system was employed for initial patient setup followed by stereoscopic kV X-ray radiographs for position verification. 6D-translational and rotational shifts were determined to correct patient position. If these shifts were above tolerance (0.7 mm translational and 1° rotational), corrections were applied and another set of X-rays was taken to verify patient position. Dosimetric impact (D95, Dmin, Dmax, and Dmean of planning target volume (PTV) compared to original plans) of positioning errors for initial IR setup (XC: Xray Correction) and post-correction (XV: X-ray Verification) was determined in a treatment planning system using a method proposed by Yue et al. (Med. Phys. 33, 21-31 (2006)) with 3D-translational errors only and 6D-translational and rotational errors. Results: Absolute mean translational errors (±standard deviation) for total 92 fractions (XC/XV) were 0.79±0.88/0.19±0.15 mm (lateral), 1.66±1.71/0.18 ±0.16 mm (longitudinal), 1.95±1.18/0.15±0.14 mm (vertical) and rotational errors were 0.61±0.47/0.17±0.15° (pitch), 0.55±0.49/0.16±0.24° (roll), and 0.68±0.73/0.16±0.15° (yaw). The average changes (loss of coverage) in D95, Dmin, Dmax, and Dmean were 4.5±7.3/0.1±0.2%, 17.8±22.5/1.1±2.5%, 0.4±1.4/0.1±0.3%, and 0.9±1.7/0.0±0.1% using 6Dshifts and 3.1±5.5/0.0±0.1%, 14.2±20.3/0.8±1.7%, 0.0±1.2/0.1±0.3%, and 0.7±1.4/0.0±0.1% using 3D-translational shifts only. The setup corrections (XC-XV) improved the PTV coverage by 4.4±7.3% (D95) and 16.7±23.5% (Dmin) using 6D adjustment. Strong correlations were observed between translation errors and deviations in dose coverage for XC. Conclusion

  17. Dosimetric impact of systematic MLC positional errors on step and shoot IMRT for prostate cancer: a planning study

    International Nuclear Information System (INIS)

    Ung, N.M.; Wee, L.; Harper, C.S.

    2010-01-01

    Full text: The positional accuracy of multi leaf collimators (MLC) is crucial in ensuring precise delivery of intensity-modulated radiotherapy (IMRT). The aim of this planning study was to investigate the dosimetric impact of systematic MLC errors on step and shoot IMRT of prostate cancer. Twelve MLC leaf banks perturbations were introduced to six prostate IMRT treatment plans to simulate MLC systematic errors. Dose volume histograms (OYHs) were generated for the extraction of dose endpoint parameters. Plans were evaluated in terms of changes to the defined endpoint dose parameters, conformity index (CI) and healthy tissue avoidance (HTA) to planning target volume (PTY), rectum and bladder. Negative perturbations of MLC had been found to produce greater changes to endpoint dose parameters than positive perturbations of MLC (p < 0.05). Negative and positive synchronized MLC perturbations of I mm resulted in median changes of -2.32 and 1.78%, respectively to 095% of PTY whereas asynchronized MLC perturbations of the same direction and magnitude resulted in median changes of 1.18 and 0.90%, respectively. Doses to rectum were generally more sensitive to systematic MLC errors compared to bladder. Synchronized MLC perturbations of I mm resulted in median changes of endpoint dose parameters to both rectum and bladder from about I to 3%. Maximum reduction of -4.44 and -7.29% were recorded for CI and HTA, respectively, due to synchronized MLC perturbation of I mm. In summary, MLC errors resulted in measurable amount of dose changes to PTY and surrounding critical structures in prostate LMRT. (author)

  18. Successful remediation of patient safety incidents: a tale of two medication errors.

    Science.gov (United States)

    Helmchen, Lorens A; Richards, Michael R; McDonald, Timothy B

    2011-01-01

    As patient safety acquires strategic importance for all stakeholders in the health care delivery chain, one promising mechanism centers on the proactive disclosure of medical errors to patients. Yet, disclosure and apology alone will not be effective in fully addressing patients' concerns after an adverse event unless they are paired with a remediation component. The purpose of this study was to identify key features of successful remediation efforts that accompany the proactive disclosure of medical errors to patients. We describe and contrast two recent and very similar cases of preventable medical error involving inappropriate medication at a large tertiary-care academic medical center in the Midwestern United States. Despite their similarity, the two medical errors led to very different health outcomes and remediation trajectories for the injured patients. Although one error causing no permanent harm was mismanaged to the lasting dissatisfaction of the patient, the other resulted in the death of the patient but was remediated to the point of allowing the family to come to terms with the loss and even restored a modicum of trust in the providers' sincerity. To maximize the opportunities for successful remediation, as soon as possible after the incident, providers should pledge to injured patients and their relatives that they will assist and accompany them in their recovery as long as necessary and then follow through on their pledge. As the two case studies show, it takes training and vigilance to ensure adherence to these principles and reach an optimal outcome for patients and their relatives.

  19. Prevalence of myopia amongst patients with refractive error in

    African Journals Online (AJOL)

    User

    retina but rather in front of it. It is the most prevalent eye defect in the world affecting ... school children has been reported as 1.7% in. Agona Swedru ... Technology. Records of all 2,803 patients who received eye care from the five randomly selected private eye care facilities between January 2010 and. December 2010 were ...

  20. Patients' knowledge and perceived reactions to medical errors in a ...

    African Journals Online (AJOL)

    EB

    2013-09-03

    Sep 3, 2013 ... concern is growing in response, there is need to report social and behavioural context of the problem in Nigeria. Objective: To examine .... advertising by law firms and if there is an explicit ... sign of respect for the patient's autonomy as dictated ... conditions, and 25.5% would not recommend the hospital ...

  1. The dose distribution and DVH change analysis wing to effect of the patient setup error

    International Nuclear Information System (INIS)

    Kim, Kyung Tae; Ju, Sang Gyu; Ahn, Jae Hong; Park, Young Hwan

    2004-01-01

    The setup error due to the patient and the staff from radiation treatment as the reason which is important the treatment record could be decided is a possibility of effect. The SET-UP ERROR of the patient analyzes the effect of dose distribution and DVH from radiation treatment of the patient. This test uses human phantom and when C-T scan doing, It rotated the Left direction of the human phantom and it made SET-UP ERROR, Standard plan and 3 mm, 5 mm, 7 mm, 10 mm, 15 mm, 20 mm with to distinguish, it made the C-T scan error. With the result, The SET-UP ERROR got each C-T image Using RTP equipment It used the plan which is used generally from clinical - Box plan, 3 Dimension plan( identical angle 5beam plan) Also, ( CTV+1cm margin, CTV+0.5cm margin, CTV+0.3,cm margin = PTV) it distinguished the standard plan and each set-up error plan and the plan used a dose distribution and the DVH and it analyzed. The Box 4 the plan and 3 Dimension plan which it bites it got similar an dose distribution and DVH in 3 mm, 5 mm From rotation error and Rectilinear movement (0%-2%). Rotation error and rectilinear error 7 mm, 10 mm, 15 mm, 20 mm appeared effect it will go mad to a enough change in treatment (2%-11%) The diminishes the effect of the SET-UP ERROR must reduce move with tension of the patient Also, we are important accessory development and the supply that it reducing of reproducibility and the move.

  2. The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors

    International Nuclear Information System (INIS)

    Rangel, Alejandra; Palte, Gesa; Dunscombe, Peter

    2010-01-01

    Purpose: Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. Methods: 9 head and neck (H and N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets (±1 mm in two banks, ±0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. Results: The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H and N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. Conclusions: None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.

  3. The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors

    Energy Technology Data Exchange (ETDEWEB)

    Rangel, Alejandra; Palte, Gesa; Dunscombe, Peter [Department of Medical Physics, Tom Baker Cancer Centre, 1331-29 Street NW, Calgary, Alberta T2N 4N2, Canada and Department of Physics and Astronomy, University of Calgary, 2500 University Drive North West, Calgary, Alberta T2N 1N4 (Canada); Department of Medical Physics, Tom Baker Cancer Centre, 1331-29 Street NW, Calgary, Alberta T2N 4N2 (Canada); Department of Medical Physics, Tom Baker Cancer Centre, 1331-29 Street NW, Calgary, Alberta T2N 4N2 (Canada); Department of Physics and Astronomy, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4 (Canada) and Department of Oncology, Tom Baker Cancer Centre, 1331-29 Street NW, Calgary, Alberta T2N 4N2 (Canada)

    2010-07-15

    Purpose: Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. Methods: 9 head and neck (H and N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets ({+-}1 mm in two banks, {+-}0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. Results: The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H and N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. Conclusions: None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.

  4. Position error compensation via a variable reluctance sensor applied to a Hybrid Vehicle Electric machine.

    Science.gov (United States)

    Bucak, Ihsan Ömür

    2010-01-01

    In the automotive industry, electromagnetic variable reluctance (VR) sensors have been extensively used to measure engine position and speed through a toothed wheel mounted on the crankshaft. In this work, an application that already uses the VR sensing unit for engine and/or transmission has been chosen to infer, this time, the indirect position of the electric machine in a parallel Hybrid Electric Vehicle (HEV) system. A VR sensor has been chosen to correct the position of the electric machine, mainly because it may still become critical in the operation of HEVs to avoid possible vehicle failures during the start-up and on-the-road, especially when the machine is used with an internal combustion engine. The proposed method uses Chi-square test and is adaptive in a sense that it derives the compensation factors during the shaft operation and updates them in a timely fashion.

  5. Position Error Compensation via a Variable Reluctance Sensor Applied to a Hybrid Vehicle Electric Machine

    Directory of Open Access Journals (Sweden)

    İhsan Ömür Bucak

    2010-03-01

    Full Text Available In the automotive industry, electromagnetic variable reluctance (VR sensors have been extensively used to measure engine position and speed through a toothed wheel mounted on the crankshaft. In this work, an application that already uses the VR sensing unit for engine and/or transmission has been chosen to infer, this time, the indirect position of the electric machine in a parallel Hybrid Electric Vehicle (HEV system. A VR sensor has been chosen to correct the position of the electric machine, mainly because it may still become critical in the operation of HEVs to avoid possible vehicle failures during the start-up and on-the-road, especially when the machine is used with an internal combustion engine. The proposed method uses Chi-square test and is adaptive in a sense that it derives the compensation factors during the shaft operation and updates them in a timely fashion.

  6. The Relationships Among Perceived Patients' Safety Culture, Intention to Report Errors, and Leader Coaching Behavior of Nurses in Korea: A Pilot Study.

    Science.gov (United States)

    Ko, YuKyung; Yu, Soyoung

    2017-09-01

    This study was undertaken to explore the correlations among nurses' perceptions of patient safety culture, their intention to report errors, and leader coaching behaviors. The participants (N = 289) were nurses from 5 Korean hospitals with approximately 300 to 500 beds each. Sociodemographic variables, patient safety culture, intention to report errors, and coaching behavior were measured using self-report instruments. Data were analyzed using descriptive statistics, Pearson correlation coefficient, the t test, and the Mann-Whitney U test. Nurses' perceptions of patient safety culture and their intention to report errors showed significant differences between groups of nurses who rated their leaders as high-performing or low-performing coaches. Perceived coaching behavior showed a significant, positive correlation with patient safety culture and intention to report errors, i.e., as nurses' perceptions of coaching behaviors increased, so did their ratings of patient safety culture and error reporting. There is a need in health care settings for coaching by nurse managers to provide quality nursing care and thus improve patient safety. Programs that are systematically developed and implemented to enhance the coaching behaviors of nurse managers are crucial to the improvement of patient safety and nursing care. Moreover, a systematic analysis of the causes of malpractice, as opposed to a focus on the punitive consequences of errors, could increase error reporting and therefore promote a culture in which a higher level of patient safety can thrive.

  7. Causes and consequences of timing errors associated with global positioning system collar accelerometer activity monitors

    Science.gov (United States)

    Adam J. Gaylord; Dana M. Sanchez

    2014-01-01

    Direct behavioral observations of multiple free-ranging animals over long periods of time and large geographic areas is prohibitively difficult. However, recent improvements in technology, such as Global Positioning System (GPS) collars equipped with motion-sensitive activity monitors, create the potential to remotely monitor animal behavior. Accelerometer-equipped...

  8. Design of a system of reference for positioning of patients in radiotherapy of breast cancer

    International Nuclear Information System (INIS)

    Nebot, P.; Reinado, D.; Salvador, R.; Gonzalez-Pena, R.; Dalmases, F.; Romero, C.; Rosello, J.; Diez, S.; Cibrian, R.

    2013-01-01

    The objective of this work is the design of a system of repositioning of the patient allowing to minimize errors both in everyday's the same placement as in the position held during the session, so that treatment would be intensified in the area to be treated, avoiding possible damage to other healthy areas. (Author)

  9. Medical error disclosure and patient safety: legal aspects

    Directory of Open Access Journals (Sweden)

    Olivier Guillod

    2013-12-01

    Full Text Available Reducing the number of preventable adverse events has become a public health issue. The paper discusses in which ways the law can contribute to that goal, especially by encouraging a culture of safety among healthcare professionals. It assesses the need or the usefulness to pass so-called disclosure laws and apology laws, to adopt mandatory but strictly confidential Critical Incidents Reporting Systems in hospitals, to change the fault-based system of medical liability or to amend the rules on criminal liability. The paper eventually calls for adding the law to the present agenda of patient safety.

  10. The alarming reality of medication error: a patient case and review of Pennsylvania and National data.

    Science.gov (United States)

    da Silva, Brianna A; Krishnamurthy, Mahesh

    2016-01-01

    A 71-year-old female accidentally received thiothixene (Navane), an antipsychotic, instead of her anti-hypertensive medication amlodipine (Norvasc) for 3 months. She sustained physical and psychological harm including ambulatory dysfunction, tremors, mood swings, and personality changes. Despite the many opportunities for intervention, multiple health care providers overlooked her symptoms. Errors occurred at multiple care levels, including prescribing, initial pharmacy dispensation, hospitalization, and subsequent outpatient follow-up. This exemplifies the Swiss Cheese Model of how errors can occur within a system. Adverse drug events (ADEs) account for more than 3.5 million physician office visits and 1 million emergency department visits each year. It is believed that preventable medication errors impact more than 7 million patients and cost almost $21 billion annually across all care settings. About 30% of hospitalized patients have at least one discrepancy on discharge medication reconciliation. Medication errors and ADEs are an underreported burden that adversely affects patients, providers, and the economy. Medication reconciliation including an 'indication review' for each prescription is an important aspect of patient safety. The decreasing frequency of pill bottle reviews, suboptimal patient education, and poor communication between healthcare providers are factors that threaten patient safety. Medication error and ADEs cost billions of health care dollars and are detrimental to the provider-patient relationship.

  11. The alarming reality of medication error: a patient case and review of Pennsylvania and National data

    Directory of Open Access Journals (Sweden)

    Brianna A. da Silva

    2016-09-01

    Full Text Available Case description: A 71-year-old female accidentally received thiothixene (Navane, an antipsychotic, instead of her anti-hypertensive medication amlodipine (Norvasc for 3 months. She sustained physical and psychological harm including ambulatory dysfunction, tremors, mood swings, and personality changes. Despite the many opportunities for intervention, multiple health care providers overlooked her symptoms. Discussion: Errors occurred at multiple care levels, including prescribing, initial pharmacy dispensation, hospitalization, and subsequent outpatient follow-up. This exemplifies the Swiss Cheese Model of how errors can occur within a system. Adverse drug events (ADEs account for more than 3.5 million physician office visits and 1 million emergency department visits each year. It is believed that preventable medication errors impact more than 7 million patients and cost almost $21 billion annually across all care settings. About 30% of hospitalized patients have at least one discrepancy on discharge medication reconciliation. Medication errors and ADEs are an underreported burden that adversely affects patients, providers, and the economy. Conclusion: Medication reconciliation including an ‘indication review’ for each prescription is an important aspect of patient safety. The decreasing frequency of pill bottle reviews, suboptimal patient education, and poor communication between healthcare providers are factors that threaten patient safety. Medication error and ADEs cost billions of health care dollars and are detrimental to the provider–patient relationship.

  12. Phonological analysis of substitution errors of patients with apraxia of speech

    Directory of Open Access Journals (Sweden)

    Maysa Luchesi Cera

    Full Text Available Abstract The literature on apraxia of speech describes the types and characteristics of phonological errors in this disorder. In general, phonemes affected by errors are described, but the distinctive features involved have not yet been investigated. Objective: To analyze the features involved in substitution errors produced by Brazilian-Portuguese speakers with apraxia of speech. Methods: 20 adults with apraxia of speech were assessed. Phonological analysis of the distinctive features involved in substitution type errors was carried out using the protocol for the evaluation of verbal and non-verbal apraxia. Results: The most affected features were: voiced, continuant, high, anterior, coronal, posterior. Moreover, the mean of the substitutions of marked to markedness features was statistically greater than the markedness to marked features. Conclusions: This study contributes toward a better characterization of the phonological errors found in apraxia of speech, thereby helping to diagnose communication disorders and the selection criteria of phonemes for rehabilitation in these patients.

  13. Three-dimensional patient setup errors at different treatment sites measured by the Tomotherapy megavoltage CT

    Energy Technology Data Exchange (ETDEWEB)

    Hui, S.K.; Lusczek, E.; Dusenbery, K. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Therapeutic Radiology - Radiation Oncology; DeFor, T. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Biostatistics and Informatics Core; Levitt, S. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Therapeutic Radiology - Radiation Oncology; Karolinska Institutet, Stockholm (Sweden). Dept. of Onkol-Patol

    2012-04-15

    Reduction of interfraction setup uncertainty is vital for assuring the accuracy of conformal radiotherapy. We report a systematic study of setup error to assess patients' three-dimensional (3D) localization at various treatment sites. Tomotherapy megavoltage CT (MVCT) images were scanned daily in 259 patients from 2005-2008. We analyzed 6,465 MVCT images to measure setup error for head and neck (H and N), chest/thorax, abdomen, prostate, legs, and total marrow irradiation (TMI). Statistical comparisons of the absolute displacements across sites and time were performed in rotation (R), lateral (x), craniocaudal (y), and vertical (z) directions. The global systematic errors were measured to be less than 3 mm in each direction with increasing order of errors for different sites: H and N, prostate, chest, pelvis, spine, legs, and TMI. The differences in displacements in the x, y, and z directions, and 3D average displacement between treatment sites were significant (p < 0.01). Overall improvement in patient localization with time (after 3-4 treatment fractions) was observed. Large displacement (> 5 mm) was observed in the 75{sup th} percentile of the patient groups for chest, pelvis, legs, and spine in the x and y direction in the second week of the treatment. MVCT imaging is essential for determining 3D setup error and to reduce uncertainty in localization at all anatomical locations. Setup error evaluation should be performed daily for all treatment regions, preferably for all treatment fractions. (orig.)

  14. Asymptomatic HIV positive patient presenting with myelopathy

    Directory of Open Access Journals (Sweden)

    Jatin Agrawal

    2016-01-01

    Full Text Available A wide variety of disorders of diverse pathogenic mechanisms can trigger spinal cord dysfunction in HIV-1-infected patients. The most common such condition is HIV-1-associated myelopathy (HAM which characteristically seen during advanced HIV infection in patients with low CD4 cell counts and previous AIDS-defining diagnoses. Histologically seen in approximately 30% of AIDS patients, but only 10% have clinical symptoms related to the disease. We describe an unusual case of HAM in previously asymptomatic patient with relatively low CD4 cell count (78 cells/mm3. The patient unaware of her seropositive status presented with a clinically slowly progressive myelopathy with difficulty in walking without assistance. We discharged a patient on antiretroviral therapy. We also review the disorders reported to derange spinal cord function in previously asymptomatic HIV-1 infected patients with preserved counts.

  15. A new approach to the form and position error measurement of the auto frame surface based on laser

    Science.gov (United States)

    Wang, Hua; Li, Wei

    2013-03-01

    Auto frame is a very large workpiece, with length up to 12 meters and width up to 2 meters, and it's very easy to know that it's inconvenient and not automatic to measure such a large workpiece by independent manual operation. In this paper we propose a new approach to reconstruct the 3D model of the large workpiece, especially the auto truck frame, based on multiple pulsed lasers, for the purpose of measuring the form and position errors. In a concerned area, it just needs one high-speed camera and two lasers. It is a fast, high-precision and economical approach.

  16. [Errors in medicine. Causes, impact and improvement measures to improve patient safety].

    Science.gov (United States)

    Waeschle, R M; Bauer, M; Schmidt, C E

    2015-09-01

    The guarantee of quality of care and patient safety is of major importance in hospitals even though increased economic pressure and work intensification are ubiquitously present. Nevertheless, adverse events still occur in 3-4 % of hospital stays and of these 25-50 % are estimated to be avoidable. The identification of possible causes of error and the development of measures for the prevention of medical errors are essential for patient safety. The implementation and continuous development of a constructive culture of error tolerance are fundamental.The origins of errors can be differentiated into systemic latent and individual active causes and components of both categories are typically involved when an error occurs. Systemic causes are, for example out of date structural environments, lack of clinical standards and low personnel density. These causes arise far away from the patient, e.g. management decisions and can remain unrecognized for a long time. Individual causes involve, e.g. confirmation bias, error of fixation and prospective memory failure. These causes have a direct impact on patient care and can result in immediate injury to patients. Stress, unclear information, complex systems and a lack of professional experience can promote individual causes. Awareness of possible causes of error is a fundamental precondition to establishing appropriate countermeasures.Error prevention should include actions directly affecting the causes of error and includes checklists and standard operating procedures (SOP) to avoid fixation and prospective memory failure and team resource management to improve communication and the generation of collective mental models. Critical incident reporting systems (CIRS) provide the opportunity to learn from previous incidents without resulting in injury to patients. Information technology (IT) support systems, such as the computerized physician order entry system, assist in the prevention of medication errors by providing

  17. Reducing wrong patient selection errors: exploring the design space of user interface techniques.

    Science.gov (United States)

    Sopan, Awalin; Plaisant, Catherine; Powsner, Seth; Shneiderman, Ben

    2014-01-01

    Wrong patient selection errors are a major issue for patient safety; from ordering medication to performing surgery, the stakes are high. Widespread adoption of Electronic Health Record (EHR) and Computerized Provider Order Entry (CPOE) systems makes patient selection using a computer screen a frequent task for clinicians. Careful design of the user interface can help mitigate the problem by helping providers recall their patients' identities, accurately select their names, and spot errors before orders are submitted. We propose a catalog of twenty seven distinct user interface techniques, organized according to a task analysis. An associated video demonstrates eighteen of those techniques. EHR designers who consider a wider range of human-computer interaction techniques could reduce selection errors, but verification of efficacy is still needed.

  18. Refractive errors in patients attending a private hospital in Jos, Nigeria

    African Journals Online (AJOL)

    2013-05-02

    May 2, 2013 ... of 6/9 or less and showed improvement in distance vision of one or more ... ninety eight patients were seen at the hospital for various eye problems. ... Two hundred twenty one (36.8%) of patients with refractive error were ... Other risk factors are ..... Myopia profile in Copenhagen medical students 1996‑98.

  19. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, J [Washington University in St Louis, Taian, Shandong (China); Yang, D [Washington University School of Medicine, St Louis, MO (United States)

    2015-06-15

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  20. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    International Nuclear Information System (INIS)

    Qiu, J; Yang, D

    2015-01-01

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  1. Calculating radiotherapy margins based on Bayesian modelling of patient specific random errors

    International Nuclear Information System (INIS)

    Herschtal, A; Te Marvelde, L; Mengersen, K; Foroudi, F; Ball, D; Devereux, T; Pham, D; Greer, P B; Pichler, P; Eade, T; Kneebone, A; Bell, L; Caine, H; Hindson, B; Kron, T; Hosseinifard, Z

    2015-01-01

    Collected real-life clinical target volume (CTV) displacement data show that some patients undergoing external beam radiotherapy (EBRT) demonstrate significantly more fraction-to-fraction variability in their displacement (‘random error’) than others. This contrasts with the common assumption made by historical recipes for margin estimation for EBRT, that the random error is constant across patients. In this work we present statistical models of CTV displacements in which random errors are characterised by an inverse gamma (IG) distribution in order to assess the impact of random error variability on CTV-to-PTV margin widths, for eight real world patient cohorts from four institutions, and for different sites of malignancy. We considered a variety of clinical treatment requirements and penumbral widths. The eight cohorts consisted of a total of 874 patients and 27 391 treatment sessions. Compared to a traditional margin recipe that assumes constant random errors across patients, for a typical 4 mm penumbral width, the IG based margin model mandates that in order to satisfy the common clinical requirement that 90% of patients receive at least 95% of prescribed RT dose to the entire CTV, margins be increased by a median of 10% (range over the eight cohorts −19% to +35%). This substantially reduces the proportion of patients for whom margins are too small to satisfy clinical requirements. (paper)

  2. Dosimetric implications of inter- and intrafractional prostate positioning errors during tomotherapy. Comparison of gold marker-based registrations with native MVCT

    Energy Technology Data Exchange (ETDEWEB)

    Wust, Peter; Joswig, Marc; Graf, Reinhold; Boehmer, Dirk; Beck, Marcus; Barelkowski, Thomasz; Budach, Volker; Ghadjar, Pirus [Charite Universitaetsmedizin Berlin, Department of Radiation Oncology and Radiotherapy, Berlin (Germany)

    2017-09-15

    For high-dose radiation therapy (RT) of prostate cancer, image-guided (IGRT) and intensity-modulated RT (IMRT) approaches are standard. Less is known regarding comparisons of different IGRT techniques and the resulting residual errors, as well as regarding their influences on dose distributions. A total of 58 patients who received tomotherapy-based RT up to 84 Gy for high-risk prostate cancer underwent IGRT based either on daily megavoltage CT (MVCT) alone (n = 43) or the additional use of gold markers (n = 15) under routine conditions. Planned Adaptive (Accuray Inc., Madison, WI, USA) software was used for elaborated offline analysis to quantify residual interfractional prostate positioning errors, along with systematic and random errors and the resulting safety margins after both IGRT approaches. Dosimetric parameters for clinical target volume (CTV) coverage and exposition of organs at risk (OAR) were also analyzed and compared. Interfractional as well as intrafractional displacements were determined. Particularly in the vertical direction, residual interfractional positioning errors were reduced using the gold marker-based approach, but dosimetric differences were moderate and the clinical relevance relatively small. Intrafractional prostate motion proved to be quite high, with displacements of 1-3 mm; however, these did not result in additional dosimetric impairments. Residual interfractional positioning errors were reduced using gold marker-based IGRT; however, this resulted in only slightly different final dose distributions. Therefore, daily MVCT-based IGRT without markers might be a valid alternative. (orig.) [German] Bei der hochdosierten Bestrahlung des Prostatakarzinoms sind die bildgesteuerte (IGRT) und die intensitaetsmodulierte Bestrahlung (IMRT) Standard. Offene Fragen gibt es beim Vergleich von IGRT-Techniken im Hinblick auf residuelle Fehler und Beeinflussungen der Dosisverteilung. Bei 58 Patienten, deren Hochrisiko-Prostatakarzinom am

  3. Refractive errors in patients attending a private hospital in Jos, Nigeria

    African Journals Online (AJOL)

    Six hundred one (20.7%) patients with distant VA which improved with refraction were considered for this analysis. Two hundred twenty one (36.8%) of patients with refractive error were visually impaired (VA <6/12-3/60). Blindness (<3/60 ‑ none perception of light) was seen in 91 (15.1%) of the patients, seven of whom were ...

  4. Aerobic training in aquatic environment improves the position sense of stroke patients: A randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Flávia de Andrade e Souza Mazuchi

    2018-03-01

    Full Text Available Abstract AIMS (Stroke patients often present sensory-motor alterations and less aerobic capacity. Joint position sense, which is crucial for balance and gait control, is also affected in stroke patients. To compare the effect of two exercise training protocols (walking in deep water and on a treadmill on the knee position sense of stroke patients. METHODS This study was designed as a randomized controlled clinical trial. Twelve adults, who suffered a stroke at least one year prior to the start of the study, were randomly assigned to one of two groups: 1 pool group submitted to aerobic deep water walking training; and 2 the treadmill group which was submitted to aerobic walk on a treadmill. Measurements: The position sense, absolute error and variable error, of the knee joint was evaluated prior to and after nine weeks of aerobic training. RESULTS The pool group presented smaller absolute (13.9o versus 6.1o; p < 0.05 and variable (9.2o versus 3.9o; p < 0.05 errors after nine-weeks gait training than the treadmill group. CONCLUSIONS Nine-week aerobic exercise intervention in aquatic environment improved precision in the position sense of the knee joint of stroke patients, suggesting a possible application in a rehabilitation program.

  5. Radiodiagnostic errors by X-ray pictures of the chest taken at bed resting patients

    Energy Technology Data Exchange (ETDEWEB)

    Ross, D.; Deininger, H.K.

    1981-03-01

    The roentgenological findings of 383 cases have been compared with the anatomical and pathological diagnosis of the autopsy report. In 29% the radiodiagnosis was incorrect. About 70% of the X-ray examinations had to be carried out succenturiately at bed side in bedridden patients. The error rate of the interpretation of these examinations was higher than in examinations under standardized conditions. Especially, carcinomatous lymphangiosis, miliary tuberculosis and pulmonary embolism can be diagnosed badly in those incomplete X-ray pictures caused by the clinical situation of the bed resting patients. The publication analyses the most common errors in the diagnosis of cardiac and pulmonary diseases, and they will be demonstrated in examples.

  6. MOST COMMON TACTICAL ERRORS IN CHRONIC SYSTOLIC HEART FAILURE PATIENTS MANAGEMENT: PRACTICAL RECOMMENDATIONS

    Directory of Open Access Journals (Sweden)

    A. S. Poskrebysheva

    2012-01-01

    Full Text Available Treatment of chronic heart failure (CHF often can be a rather difficult task. Proper selection of therapy and strict adherence to the recommendations is vital in these patients. Unfortunately, in practice we often encounter with free interpretation of the recommendations, which leads to tactical errors and reduce the effectiveness of treatment. This article deals with the most common tactical errors, and contains recommendations for the management of patients with CHF, which can be very useful to the practitioner.

  7. MOST COMMON TACTICAL ERRORS IN CHRONIC SYSTOLIC HEART FAILURE PATIENTS MANAGEMENT: PRACTICAL RECOMMENDATIONS

    Directory of Open Access Journals (Sweden)

    A. S. Poskrebysheva

    2014-07-01

    Full Text Available Treatment of chronic heart failure (CHF often can be a rather difficult task. Proper selection of therapy and strict adherence to the recommendations is vital in these patients. Unfortunately, in practice we often encounter with free interpretation of the recommendations, which leads to tactical errors and reduce the effectiveness of treatment. This article deals with the most common tactical errors, and contains recommendations for the management of patients with CHF, which can be very useful to the practitioner.

  8. Impact of Communication Errors in Radiology on Patient Care, Customer Satisfaction, and Work-Flow Efficiency.

    Science.gov (United States)

    Siewert, Bettina; Brook, Olga R; Hochman, Mary; Eisenberg, Ronald L

    2016-03-01

    The purpose of this study is to analyze the impact of communication errors on patient care, customer satisfaction, and work-flow efficiency and to identify opportunities for quality improvement. We performed a search of our quality assurance database for communication errors submitted from August 1, 2004, through December 31, 2014. Cases were analyzed regarding the step in the imaging process at which the error occurred (i.e., ordering, scheduling, performance of examination, study interpretation, or result communication). The impact on patient care was graded on a 5-point scale from none (0) to catastrophic (4). The severity of impact between errors in result communication and those that occurred at all other steps was compared. Error evaluation was performed independently by two board-certified radiologists. Statistical analysis was performed using the chi-square test and kappa statistics. Three hundred eighty of 422 cases were included in the study. One hundred ninety-nine of the 380 communication errors (52.4%) occurred at steps other than result communication, including ordering (13.9%; n = 53), scheduling (4.7%; n = 18), performance of examination (30.0%; n = 114), and study interpretation (3.7%; n = 14). Result communication was the single most common step, accounting for 47.6% (181/380) of errors. There was no statistically significant difference in impact severity between errors that occurred during result communication and those that occurred at other times (p = 0.29). In 37.9% of cases (144/380), there was an impact on patient care, including 21 minor impacts (5.5%; result communication, n = 13; all other steps, n = 8), 34 moderate impacts (8.9%; result communication, n = 12; all other steps, n = 22), and 89 major impacts (23.4%; result communication, n = 45; all other steps, n = 44). In 62.1% (236/380) of cases, no impact was noted, but 52.6% (200/380) of cases had the potential for an impact. Among 380 communication errors in a radiology department, 37

  9. Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position

    International Nuclear Information System (INIS)

    Stoiber, Eva Maria; Giske, Kristina; Schubert, Kai; Sterzing, Florian; Habl, Gregor; Uhl, Matthias; Herfarth, Klaus; Bendl, Rolf; Debus, Jürgen

    2011-01-01

    Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived from a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right–left and anterior–posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.

  10. A mediation skills model to manage disclosure of errors and adverse events to patients.

    Science.gov (United States)

    Liebman, Carol B; Hyman, Chris Stern

    2004-01-01

    In 2002 Pennsylvania became the first state to impose on hospitals a statutory duty to notify patients in writing of a serious event. If the disclosure conversations are carefully planned, properly executed, and responsive to patients' needs, this new requirement creates possible benefits for both patient safety and litigation risk management. This paper describes a model for accomplishing these goals that encourages health care providers to communicate more effectively with patients following an adverse event or medical error, learn from mistakes, respond to the concerns of patients and families after an adverse event, and arrive at a fair and cost-effective resolution of valid claims.

  11. Cognitive moderators of children's adjustment to stressful divorce events: the role of negative cognitive errors and positive illusions.

    Science.gov (United States)

    Mazur, E; Wolchik, S A; Virdin, L; Sandler, I N; West, S G

    1999-01-01

    This study examined whether children's cognitive appraisal biases moderate the impact of stressful divorce-related events on psychological adjustment in 355 children ages 9 to 12, whose families had experienced divorce within the past 2 years. Multiple regression indicated that endorsement of negative cognitive errors for hypothetical divorce events moderates the relations between stressful divorce events and self- and maternal reports of internalizing and externalizing symptoms, but only for older children. Positive illusions buffer the effects of stressful divorce events on child-reported depression and mother-reported externalizing problems. Implications of these results for theories of stress and coping, as well as for interventions for children of divorced families, are discussed.

  12. Prevalence of positive autoimmune biomarkers in the brucellosis patients.

    Science.gov (United States)

    Ahmadinejad, Zahra; Abdollahi, Alireza; Ziaee, Vahid; Domiraei, Zeinab; Najafizadeh, Seyed-Reza; Jafari, Sirus; Ahmadinejad, Mahdi

    2016-10-01

    Brucellosis is a chronic infectious disease with articular involvement. Discrimination between brucellosis and rheumatologic disorders is difficult in regions endemic for brucellosis. There are few studies about the rate of positive autoantibodies as rheumatologic biomarkers in brucellosis, and the prevalence is variable. In this study, the rheumatologic tests were studied in brucellosis patients. This cross sectional study was performed in two teaching hospitals in Tehran, Iran. Forty-nine patients with brucella infection and 42 healthy participants were enrolled in this study. Brucellosis was diagnosed on the basis of the clinical symptoms and positive serology for brucellosis. Rheumatic factor (RF) and antinuclear antibodies (ANA) were evaluated in all patients. Cyclic citrullinated peptides antibody (ACPA) and anti-double strand DNA (anti-dsDNA) were checked in all patients and control groups. Out of 49 patients, 15 (30.6 %) were RF positive and 4 (8.2 %) were ANA positive. Anti-dsDNA was concurrently positive with ANA in 1 patient (2 %) but ACPA titer was positive in 8 patients (16.3 %). None of the patients with positive autoantibody biomarkers fulfilled the criteria for rheumatologic disorders. The rate of positive RF in healthy people was significantly lower than patient group (2.4 vs. 30.6 %), but the positiveness rate of other biomarkers did not have significant difference in two groups. Sixty percent of the patients with positive RF and 75 % with positive ACPA had skeletal involvement (P brucellosis. Rheumatologists should be aware of brucellosis in patients with musculoskeletal involvement and positive autoantibody biomarkers in endemic regions.

  13. Why HIV Positive Patients on Antiretroviral Treatment and/or ...

    African Journals Online (AJOL)

    Why HIV Positive Patients on Antiretroviral Treatment and/or Cotrimoxazole Prophylaxis Use Traditional Medicine: Perceptions of Health Workers, Traditional Healers and Patients: A Study in Two Provinces of South Africa.

  14. An intervention to decrease patient identification band errors in a children's hospital.

    Science.gov (United States)

    Hain, Paul D; Joers, B; Rush, M; Slayton, J; Throop, P; Hoagg, S; Allen, L; Grantham, J; Deshpande, J K

    2010-06-01

    Patient misidentification continues to be a quality and safety issue. There is a paucity of US data describing interventions to reduce identification band error rates. Monroe Carell Jr Children's Hospital at Vanderbilt. Percentage of patients with defective identification bands. Web-based surveys were sent, asking hospital personnel to anonymously identify perceived barriers to reaching zero defects with identification bands. Corrective action plans were created and implemented with ideas from leadership, front-line staff and the online survey. Data from unannounced audits of patient identification bands were plotted on statistical process control charts and shared monthly with staff. All hospital personnel were expected to "stop the line" if there were any patient identification questions. The first audit showed a defect rate of 20.4%. The original mean defect rate was 6.5%. After interventions and education, the new mean defect rate was 2.6%. (a) The initial rate of patient identification band errors in the hospital was higher than expected. (b) The action resulting in most significant improvement was staff awareness of the problem, with clear expectations to immediately stop the line if a patient identification error was present. (c) Staff surveys are an excellent source of suggestions for combating patient identification issues. (d) Continued audit and data collection is necessary for sustainable staff focus and continued improvement. (e) Statistical process control charts are both an effective method to track results and an easily understood tool for sharing data with staff.

  15. Can stimulating massage improve joint repositioning error in patients with knee osteoarthritis?

    DEFF Research Database (Denmark)

    Lund, Hans; Henriksen, Marius; Bartels, Else M

    2009-01-01

    PURPOSE: The purpose of this study was to investigate the effect of massage applied to the thigh muscles on joint repositioning error (JRE) in patients suffering from osteoarthritis (OA).We hypothesized that stimulating massage of the muscles around an osteoarthritic knee joint, could improve the...

  16. Using total quality management approach to improve patient safety by preventing medication error incidences*.

    Science.gov (United States)

    Yousef, Nadin; Yousef, Farah

    2017-09-04

    Whereas one of the predominant causes of medication errors is a drug administration error, a previous study related to our investigations and reviews estimated that the incidences of medication errors constituted 6.7 out of 100 administrated medication doses. Therefore, we aimed by using six sigma approach to propose a way that reduces these errors to become less than 1 out of 100 administrated medication doses by improving healthcare professional education and clearer handwritten prescriptions. The study was held in a General Government Hospital. First, we systematically studied the current medication use process. Second, we used six sigma approach by utilizing the five-step DMAIC process (Define, Measure, Analyze, Implement, Control) to find out the real reasons behind such errors. This was to figure out a useful solution to avoid medication error incidences in daily healthcare professional practice. Data sheet was used in Data tool and Pareto diagrams were used in Analyzing tool. In our investigation, we reached out the real cause behind administrated medication errors. As Pareto diagrams used in our study showed that the fault percentage in administrated phase was 24.8%, while the percentage of errors related to prescribing phase was 42.8%, 1.7 folds. This means that the mistakes in prescribing phase, especially because of the poor handwritten prescriptions whose percentage in this phase was 17.6%, are responsible for the consequent) mistakes in this treatment process later on. Therefore, we proposed in this study an effective low cost strategy based on the behavior of healthcare workers as Guideline Recommendations to be followed by the physicians. This method can be a prior caution to decrease errors in prescribing phase which may lead to decrease the administrated medication error incidences to less than 1%. This improvement way of behavior can be efficient to improve hand written prescriptions and decrease the consequent errors related to administrated

  17. Identification of Special Patterns of Numerical Typographic Errors to Increases the Likelihood of Finding a Misplaced Patient File

    OpenAIRE

    Sun, Ying-Chou; Tang, Dah-Dian; Zeng, Qing; Greenes, Robert

    2001-01-01

    When a typographic error of a patient identification number occurs on a patient document such as an envelope for radiology films or the cover of a patient record, it will result in misplacement of the document. Once misplaced, such documents are often extremely difficult to recover. After analyzing 290 numerical typos, we found that errors do not occur randomly. Instead, many of the typos share certain specific patterns. Six major types of non-random numeral typographic error patterns have be...

  18. Identification of Special Patterns of Numerical Typographic Errors Increases the Likelihood of Finding a Misplaced Patient File

    OpenAIRE

    Sun, Ying-Chou; Tang, Dah-Dian; Zeng, Qing; Greenes, Robert

    2002-01-01

    When a typographic error of a patient identification number occurs on a patient document such as an envelope for radiology films or the cover of a patient record, it will result in misplacement of the document. Once misplaced, such documents are often extremely difficult to recover. After analyzing 290 numerical typos, we found that errors do not occur randomly. Instead, many of the typos share certain specific patterns. Six major types of non-random numeral typographic error patterns have be...

  19. Variability of centric relation position in TMD patients.

    NARCIS (Netherlands)

    Zonnenberg, A.J.J.; Mulder, J.

    2006-01-01

    Reproducibility of the centric relation position for patients with temporomandibular disorders (TMD) is not documented in the current literature. It was the objective of this study to assess clinical variability of the centric relation position for TMD patients with a muscle-determined technique by

  20. Residual setup errors caused by rotation and non-rigid motion in prone-treated cervical cancer patients after online CBCT image-guidance

    International Nuclear Information System (INIS)

    Ahmad, Rozilawati; Hoogeman, Mischa S.; Quint, Sandra; Mens, Jan Willem; Osorio, Eliana M. Vásquez; Heijmen, Ben J.M.

    2012-01-01

    Purpose: To quantify the impact of uncorrected or partially corrected pelvis rotation and spine bending on region-specific residual setup errors in prone-treated cervical cancer patients. Methods and materials: Fifteen patients received an in-room CBCT scan twice a week. CBCT scans were registered to the planning CT-scan using a pelvic clip box and considering both translations and rotations. For daily correction of the detected translational pelvis setup errors by couch shifts, residual setup errors were determined for L5, L4 and seven other points of interest (POIs). The same was done for a procedure with translational corrections and limited rotational correction (±3°) by a 6D positioning device. Results: With translational correction only, residual setup errors were large especially for L5/L4 in AP direction (Σ = 5.1/5.5 mm). For the 7 POIs the residual setup errors ranged from 1.8 to 5.6 mm (AP). Using the 6D positioning device, the errors were substantially smaller (for L5/L4 in AP direction Σ = 2.7/2.2 mm). Using this device, the percentage of fractions with a residual AP displacement for L4 > 5 mm reduced from 47% to 9%. Conclusions: Setup variations caused by pelvis rotations are large and cannot be ignored in prone treatment of cervical cancer patients. Corrections with a 6D positioning device may considerably reduce resulting setup errors, but the residual setup errors should still be accounted for by appropriate CTV-to-PTV margins.

  1. Characteristics of number transcoding errors of Chinese- versus English-speaking Alzheimer's disease patients.

    Science.gov (United States)

    Ting, Simon Kang Seng; Chia, Pei Shi; Kwek, Kevin; Tan, Wilnard; Hameed, Shahul

    2016-10-01

    Number processing disorder is an acquired deficit in mathematical skills commonly observed in Alzheimer's disease (AD), usually as a consequence of neurological dysfunction. Common impairments include syntactic errors (800012 instead of 8012) and intrusion errors (8 thousand and 12 instead of eight thousand and twelve) in number transcoding tasks. This study aimed to understand the characterization of AD-related number processing disorder within an alphabetic language (English) and ideographical language (Chinese), and to investigate the differences between alphabetic and ideographic language processing. Chinese-speaking AD patients were hypothesized to make significantly more intrusion errors than English-speaking ones, due to the ideographical nature of both Chinese characters and Arabic numbers. A simplified number transcoding test derived from EC301 battery was administered to AD patients. Chinese-speaking AD patients made significantly more intrusion errors (p = 0.001) than English speakers. This demonstrates that number processing in an alphabetic language such as English does not function in the same manner as in Chinese. The impaired inhibition capability likely contributes to such observations due to its competitive lexical representation in brain for Chinese speakers.

  2. A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy

    International Nuclear Information System (INIS)

    Boswell, Sarah A.; Jeraj, Robert; Ruchala, Kenneth J.; Olivera, Gustavo H.; Jaradat, Hazim A.; James, Joshua A.; Gutierrez, Alonso; Pearson, Dave; Frank, Gary; Mackie, T. Rock

    2005-01-01

    An accurate means of determining and correcting for daily patient setup errors is important to the cancer outcome in radiotherapy. While many tools have been developed to detect setup errors, difficulty may arise in accurately adjusting the patient to account for the rotational error components. A novel, automated method to correct for rotational patient setup errors in helical tomotherapy is proposed for a treatment couch that is restricted to motion along translational axes. In tomotherapy, only a narrow superior/inferior section of the target receives a dose at any instant, thus rotations in the sagittal and coronal planes may be approximately corrected for by very slow continuous couch motion in a direction perpendicular to the scanning direction. Results from proof-of-principle tests indicate that the method improves the accuracy of treatment delivery, especially for long and narrow targets. Rotational corrections about an axis perpendicular to the transverse plane continue to be implemented easily in tomotherapy by adjustment of the initial gantry angle

  3. Detention and positioning system for patient Treatment with conventional radiotherapy

    International Nuclear Information System (INIS)

    Hueso Bernad, Nuria; Tirado Porcar, Miriam; Del Castillo Arres, M. Jose; Broseta Tormos, M. Mercedes; Franch Martinez, Silvia; Suarez Dieguez, Raquel; Roures Ramos, M.Teresa

    2009-01-01

    The first step in what we call in radiotherapy S imulation and Planning o f radiation, is the correct choice of patient position and methods to use for this position is maintained along both the simulation and planning as the radiation treatment. The choice of position is directly linked to the choice of immobilizer to be used. (Author)

  4. SU-F-J-131: Reproducibility of Positioning Error Due to Temporarily Indwelled Urethral Catheter for Urethra-Sparing Prostate IMRT

    International Nuclear Information System (INIS)

    Hirose, K; Takai, Y; Sato, M; Hatayama, Y; Kawaguchi, H; Aoki, M; Akimoto, H; Komai, F; Souma, M; Obara, H; Suzuki, M

    2016-01-01

    Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostate at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by

  5. SU-F-J-131: Reproducibility of Positioning Error Due to Temporarily Indwelled Urethral Catheter for Urethra-Sparing Prostate IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Hirose, K; Takai, Y [Hirosaki University, Hirosaki (Japan); Southern Tohoku BNCT Research Center, Koriyama (Japan); Sato, M; Hatayama, Y; Kawaguchi, H; Aoki, M; Akimoto, H [Hirosaki University, Hirosaki (Japan); Komai, F; Souma, M; Obara, H; Suzuki, M [Hirosaki University Hospital, Hirosaki (Japan)

    2016-06-15

    Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostate at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by

  6. Patient identification error among prostate needle core biopsy specimens--are we ready for a DNA time-out?

    Science.gov (United States)

    Suba, Eric J; Pfeifer, John D; Raab, Stephen S

    2007-10-01

    Patient identification errors in surgical pathology often involve switches of prostate or breast needle core biopsy specimens among patients. We assessed strategies for decreasing the occurrence of these uncommon and yet potentially catastrophic events. Root cause analyses were performed following 3 cases of patient identification error involving prostate needle core biopsy specimens. Patient identification errors in surgical pathology result from slips and lapses of automatic human action that may occur at numerous steps during pre-laboratory, laboratory and post-laboratory work flow processes. Patient identification errors among prostate needle biopsies may be difficult to entirely prevent through the optimization of work flow processes. A DNA time-out, whereby DNA polymorphic microsatellite analysis is used to confirm patient identification before radiation therapy or radical surgery, may eliminate patient identification errors among needle biopsies.

  7. Patient satisfaction and positive patient outcomes in ambulatory anesthesia

    Directory of Open Access Journals (Sweden)

    Shah U

    2015-04-01

    Full Text Available Ushma Shah, David T Wong, Jean Wong Department of Anesthesia, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, ON, Canada Abstract: Most surgeries in North America are performed on an ambulatory basis, reducing health care costs and increasing patient comfort. Patient satisfaction is an important outcome indicator of the quality of health care services incorporated by the American Society of Anesthesiologists (ASA. Patient satisfaction is a complex concept that is influenced by multiple factors. A patient's viewpoint and knowledge plays an influential role in patient satisfaction with ambulatory surgery. Medical optimization and psychological preparation of the patient plays a pivotal role in the success of ambulatory surgery. Postoperative pain, nausea, and vomiting are the most important symptoms for the patient and can be addressed by multimodal drug regimens. Shared decision making, patient–provider relationship, communication, and continuity of care form the main pillars of patient satisfaction. Various psychometrically developed instruments are available to measure patient satisfaction, such as the Iowa Satisfaction with Anesthesia Scale and Evaluation du Vecu de I'Anesthesie Generale, but none have been developed specifically for ambulatory surgery. The ASA has made recommendations for data collection for patient satisfaction surveys and emphasized the importance of reporting the data to the Anesthesia Quality Institute. Future research is warranted to develop a validated tool to measure patient satisfaction in ambulatory surgery. Keywords: patient, satisfaction, anesthesia, outcomes, questionnaire, perspectives

  8. The incidence and types of medication errors in patients receiving antiretroviral therapy in resource-constrained settings.

    Directory of Open Access Journals (Sweden)

    Kenneth Anene Agu

    Full Text Available This study assessed the incidence and types of medication errors, interventions and outcomes in patients on antiretroviral therapy (ART in selected HIV treatment centres in Nigeria.Of 69 health facilities that had program for active screening of medication errors, 14 were randomly selected for prospective cohort assessment. All patients who filled/refilled their antiretroviral medications between February 2009 and March 2011 were screened for medication errors using study-specific pharmaceutical care daily worksheet (PCDW. All potential or actual medication errors identified, interventions provided and the outcomes were documented in the PCDW. Interventions included pharmaceutical care in HIV training for pharmacists amongst others. Chi-square was used for inferential statistics and P0.05. The major medications errors identified were 26.4% incorrect ART regimens prescribed; 19.8% potential drug-drug interaction or contraindication present; and 16.6% duration and/or frequency of medication inappropriate. Interventions provided included 67.1% cases of prescriber contacted to clarify/resolve errors and 14.7% cases of patient counselling and education; 97.4% of potential/actual medication error(s were resolved.The incidence rate of medication errors was somewhat high; and majority of identified errors were related to prescription of incorrect ART regimens and potential drug-drug interactions; the prescriber was contacted and the errors were resolved in majority of cases. Active screening for medication errors is feasible in resource-limited settings following a capacity building intervention.

  9. Error signals in the subthalamic nucleus are related to post-error slowing in patients with Parkinson's disease

    NARCIS (Netherlands)

    Siegert, S.; Herrojo Ruiz, M.; Brücke, C.; Hueble, J.; Schneider, H.G.; Ullsperger, M.; Kühn, A.A.

    2014-01-01

    Error monitoring is essential for optimizing motor behavior. It has been linked to the medial frontal cortex, in particular to the anterior midcingulate cortex (aMCC). The aMCC subserves its performance-monitoring function in interaction with the basal ganglia (BG) circuits, as has been demonstrated

  10. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

    Science.gov (United States)

    Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J

    2015-01-01

    To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  11. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2015-06-01

    Full Text Available AIM:To evaluate the prediction error in intraocular lens (IOL power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP.METHODS:Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany. In all cases, an adjusted IOL power (PIOLadj was calculated based on Gaussian optics using a variable keratometric index value (nkadj for the estimation of the corneal power (Pkadj and on a new value for ELP (ELPadj obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay Ⅰ.RESULTS:PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05. In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D and limits of agreement (of 1.47 and -1.61 D when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01 and was found to be dependent on axial length, anterior chamber depth and Pkadj.CONCLUSION:Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  12. [Patient safety and errors in medicine: development, prevention and analyses of incidents].

    Science.gov (United States)

    Rall, M; Manser, T; Guggenberger, H; Gaba, D M; Unertl, K

    2001-06-01

    "Patient safety" and "errors in medicine" are issues gaining more and more prominence in the eyes of the public. According to newer studies, errors in medicine are among the ten major causes of death in association with the whole area of health care. A new era has begun incorporating attention to a "systems" approach to deal with errors and their causes in the health system. In other high-risk domains with a high demand for safety (such as the nuclear power industry and aviation) many strategies to enhance safety have been established. It is time to study these strategies, to adapt them if necessary and apply them to the field of medicine. These strategies include: to teach people how errors evolve in complex working domains and how types of errors are classified; the introduction of critical incident reporting systems that are free of negative consequences for the reporters; the promotion of continuous medical education; and the development of generic problem-solving skills incorporating the extensive use of realistic simulators wherever possible. Interestingly, the field of anesthesiology--within which realistic simulators were developed--is referred to as a model for the new patient safety movement. Despite this proud track record in recent times though, there is still much to be done even in the field of anesthesiology. Overall though, the most important strategy towards a long-term improvement in patient safety will be a change of "culture" throughout the entire health care system. The "culture of blame" focused on individuals should be replaced by a "safety culture", that sees errors and critical incidents as a problem of the whole organization. The acceptance of human fallability and an open-minded non-punitive analysis of errors in the sense of a "preventive and proactive safety culture" should lead to solutions at the systemic level. This change in culture can only be achieved with a strong commitment from the highest levels of an organization. Patient

  13. Improving Patient Safety With Error Identification in Chemotherapy Orders by Verification Nurses.

    Science.gov (United States)

    Baldwin, Abigail; Rodriguez, Elizabeth S

    2016-02-01

    The prevalence of medication errors associated with chemotherapy administration is not precisely known. Little evidence exists concerning the extent or nature of errors; however, some evidence demonstrates that errors are related to prescribing. This article demonstrates how the review of chemotherapy orders by a designated nurse known as a verification nurse (VN) at a National Cancer Institute-designated comprehensive cancer center helps to identify prescribing errors that may prevent chemotherapy administration mistakes and improve patient safety in outpatient infusion units. This article will describe the role of the VN and details of the verification process. To identify benefits of the VN role, a retrospective review and analysis of chemotherapy near-miss events from 2009-2014 was performed. A total of 4,282 events related to chemotherapy were entered into the Reporting to Improve Safety and Quality system. A majority of the events were categorized as near-miss events, or those that, because of chance, did not result in patient injury, and were identified at the point of prescribing.

  14. A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, J. P.; McNamara, J.; Yorke, E.; Pham, H.; Rimner, A.; Rosenzweig, K. E.; Mageras, G. S. [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States)

    2012-10-15

    Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged images for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction

  15. A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

    International Nuclear Information System (INIS)

    Santoro, J. P.; McNamara, J.; Yorke, E.; Pham, H.; Rimner, A.; Rosenzweig, K. E.; Mageras, G. S.

    2012-01-01

    Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged images for determining tumor deviations. Methods: Eleven stage II–IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction

  16. Local setup errors in image-guided radiotherapy for head and neck cancer patients immobilized with a custom-made device.

    Science.gov (United States)

    Giske, Kristina; Stoiber, Eva M; Schwarz, Michael; Stoll, Armin; Muenter, Marc W; Timke, Carmen; Roeder, Falk; Debus, Juergen; Huber, Peter E; Thieke, Christian; Bendl, Rolf

    2011-06-01

    To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future. Copyright © 2011 Elsevier Inc. All rights

  17. Child and family experiences with inborn errors of metabolism: a qualitative interview study with representatives of patient groups.

    Science.gov (United States)

    Khangura, Sara D; Tingley, Kylie; Chakraborty, Pranesh; Coyle, Doug; Kronick, Jonathan B; Laberge, Anne-Marie; Little, Julian; Miller, Fiona A; Mitchell, John J; Prasad, Chitra; Siddiq, Shabnaz; Siriwardena, Komudi; Sparkes, Rebecca; Speechley, Kathy N; Stockler, Sylvia; Trakadis, Yannis; Wilson, Brenda J; Wilson, Kumanan; Potter, Beth K

    2016-01-01

    Patient-centered health care for children with inborn errors of metabolism (IEM) and their families is important and requires an understanding of patient experiences, needs, and priorities. IEM-specific patient groups have emerged as important voices within these rare disease communities and are uniquely positioned to contribute to this understanding. We conducted qualitative interviews with IEM patient group representatives to increase understanding of patient and family experiences, needs, and priorities and inform patient-centered research and care. We developed a sampling frame of patient groups representing IEM disease communities from Canada, the United States, and United Kingdom. With consent, we interviewed participants to explore their views on experiences, needs, and outcomes that are most important to children with IEM and their families. We analyzed the data using a qualitative descriptive approach to identify key themes and sub-themes. We interviewed 18 organizational representatives between February 28 and September 17, 2014, representing 16 IEMs and/or disease categories. Twelve participants voluntarily self-identified as parents and/or were themselves patients. Three key themes emerged from the coded data: managing the uncertainty associated with raising and caring for a child with a rare disease; challenges associated with the affected child's life transitions, and; the collective struggle for improved outcomes and interventions that rare disease communities navigate. Health care providers can support children with IEM and their families by acknowledging and reducing uncertainty, supporting families through children's life transitions, and contributing to rare disease communities' progress toward improved interventions, experiences, and outcomes.

  18. [Medication errors in a hospital emergency department: study of the current situation and critical points for improving patient safety].

    Science.gov (United States)

    Pérez-Díez, Cristina; Real-Campaña, José Manuel; Noya-Castro, María Carmen; Andrés-Paricio, Felicidad; Reyes Abad-Sazatornil, María; Bienvenido Povar-Marco, Javier

    2017-01-01

    To determine the frequency of medication errors and incident types in a tertiary-care hospital emergency department. To quantify and classify medication errors and identify critical points where measures should be implemented to improve patient safety. Prospective direct-observation study to detect errors made in June and July 2016. The overall error rate was 23.7%. The most common errors were made while medications were administered (10.9%). We detected 1532 incidents: 53.6% on workdays (P=.001), 43.1% during the afternoon/evening shift (P=.004), and 43.1% in observation areas (P=.004). The medication error rate was significant. Most errors and incidents occurred during the afternoon/evening shift and in the observation area. Most errors were related to administration of medications.

  19. Radiodiagnostic errors by X-ray pictures of the chest taken at bed resting patients

    International Nuclear Information System (INIS)

    Ross, D.; Deininger, H.K.

    1981-01-01

    The roentgenological findings of 383 cases have been compared with the anatomical and pathological diagnosis of the autopsy report. In 29% the radiodiagnosis was incorrect. About 70% of the X-ray examinations had to be carried out succenturiately at bed side in bedridden patients. The error rate of the interpretation of these examinations was higher than in examinations under standardized conditions. Especially, carcinomatous lymphangiosis, miliary tuberculosis and pulmonary embolism can be diagnosed badly in those incomplete X-ray pictures caused by the clinical situation of the bed resting patients. The publication analyses the most common errors in the diagnosis of cardiac and pulmonary diseases, and they will be demonstrated in examples. (orig.) [de

  20. TU-AB-201-05: Automatic Adaptive Per-Operative Re-Planning for HDR Prostate Brachytherapy - a Simulation Study On Errors in Needle Positioning

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Senneville, B Denis de; Hautvast, G; Binnekamp, D

    2015-01-01

    Purpose: To develop adaptive planning with feedback for MRI-guided focal HDR prostate brachytherapy with a single divergent needle robotic implant device. After each needle insertion, the dwell positions for that needle are calculated and the positioning of remaining needles and dosimetry are both updated based on MR imaging. Methods: Errors in needle positioning may occur due to inaccurate needle insertion (caused by e.g. the needle’s bending) and unpredictable changes in patient anatomy. Consequently, the dose plan quality might dramatically decrease compared to the preplan. In this study, a procedure was developed to re-optimize, after each needle insertion, the remaining needle angulations, source positions and dwell times in order to obtain an optimal coverage (D95% PTV>19 Gy) without exceeding the constraints of the organs at risk (OAR) (D10% urethra<21 Gy, D1cc bladder<12 Gy and D1cc rectum<12 Gy). Complete HDR procedures with 6 needle insertions were simulated for a patient MR-image set with PTV, prostate, urethra, bladder and rectum delineated. Random angulation errors, modeled by a Gaussian distribution (standard deviation of 3 mm at the needle’s tip), were generated for each needle insertion. We compared the final dose parameters for the situations (I) without re-optimization and (II) with the automatic feedback. Results: The computation time of replanning was below 100 seconds on a current desk computer. For the patient tested, a clinically acceptable dose plan was achieved while applying the automatic feedback (median(range) in Gy, D95% PTV: 19.9(19.3–20.3), D10% urethra: 13.4(11.9–18.0), D1cc rectum: 11.0(10.7–11.6), D1cc bladder: 4.9(3.6–6.8)). This was not the case without re-optimization (median(range) in Gy, D95% PTV: 19.4(14.9–21.3), D10% urethra: 12.6(11.0–15.7), D1cc rectum: 10.9(8.9–14.1), D1cc bladder: 4.8(4.4–5.2)). Conclusion: An automatic guidance strategy for HDR prostate brachytherapy was developed to compensate

  1. Learned helplessness, cognitive errors and perfectionism in depressed and non-depressed chronic pain patients

    OpenAIRE

    2014-01-01

    M.A. (Clinical Psychology) The increasing interest in cognitive factors both in the literature on pain and in developments in research on depression has led to the present study, where cognitive factors associated with depression were investigated in clinical groups of chroni c pa in patients. The cognitive factors studied were learned helplessness (Seligman, 1975), cognitive errors and distortions (Beck, 1976), perfectionism (Bums, 19800 1980b), as well as hopelessness (Beck, 1974). It wa...

  2. Psychometric properties of the national eye institute refractive error correction quality-of-life questionnaire among Iranian patients

    Directory of Open Access Journals (Sweden)

    Amir H Pakpour

    2013-01-01

    Conclusions: The Iranian version of the NEI-RQL-42 is a valid and reliable instrument to assess refractive error correction quality-of-life in Iranian patients. Moreover this questionnaire can be used to evaluate the effectiveness of interventions in patients with refractive errors.

  3. Overcoming function annotation errors in the Gram-positive pathogen Streptococcus suis by a proteomics-driven approach

    Directory of Open Access Journals (Sweden)

    Bárcena José A

    2008-12-01

    Full Text Available Abstract Background Annotation of protein-coding genes is a key step in sequencing projects. Protein functions are mainly assigned on the basis of the amino acid sequence alone by searching of homologous proteins. However, fully automated annotation processes often lead to wrong prediction of protein functions, and therefore time-intensive manual curation is often essential. Here we describe a fast and reliable way to correct function annotation in sequencing projects, focusing on surface proteomes. We use a proteomics approach, previously proven to be very powerful for identifying new vaccine candidates against Gram-positive pathogens. It consists of shaving the surface of intact cells with two proteases, the specific cleavage-site trypsin and the unspecific proteinase K, followed by LC/MS/MS analysis of the resulting peptides. The identified proteins are contrasted by computational analysis and their sequences are inspected to correct possible errors in function prediction. Results When applied to the zoonotic pathogen Streptococcus suis, of which two strains have been recently sequenced and annotated, we identified a set of surface proteins without cytoplasmic contamination: all the proteins identified had exporting or retention signals towards the outside and/or the cell surface, and viability of protease-treated cells was not affected. The combination of both experimental evidences and computational methods allowed us to determine that two of these proteins are putative extracellular new adhesins that had been previously attributed a wrong cytoplasmic function. One of them is a putative component of the pilus of this bacterium. Conclusion We illustrate the complementary nature of laboratory-based and computational methods to examine in concert the localization of a set of proteins in the cell, and demonstrate the utility of this proteomics-based strategy to experimentally correct function annotation errors in sequencing projects. This

  4. A systematic review of patient medication error on self-administering medication at home.

    Science.gov (United States)

    Mira, José Joaquín; Lorenzo, Susana; Guilabert, Mercedes; Navarro, Isabel; Pérez-Jover, Virtudes

    2015-06-01

    Medication errors have been analyzed as a health professionals' responsibility (due to mistakes in prescription, preparation or dispensing). However, sometimes, patients themselves (or their caregivers) make mistakes in the administration of the medication. The epidemiology of patient medication errors (PEs) has been scarcely reviewed in spite of its impact on people, on therapeutic effectiveness and on incremental cost for the health systems. This study reviews and describes the methodological approaches and results of published studies on the frequency, causes and consequences of medication errors committed by patients at home. A review of research articles published between 1990 and 2014 was carried out using MEDLINE, Web-of-Knowledge, Scopus, Tripdatabase and Index Medicus. The frequency of PE was situated between 19 and 59%. The elderly and the preschooler population constituted a higher number of mistakes than others. The most common were: incorrect dosage, forgetting, mixing up medications, failing to recall indications and taking out-of-date or inappropriately stored drugs. The majority of these mistakes have no negative consequences. Health literacy, information and communication and complexity of use of dispensing devices were identified as causes of PEs. Apps and other new technologies offer several opportunities for improving drug safety.

  5. [Prospective assessment of medication errors in critically ill patients in a university hospital].

    Science.gov (United States)

    Salazar L, Nicole; Jirón A, Marcela; Escobar O, Leslie; Tobar, Eduardo; Romero, Carlos

    2011-11-01

    Critically ill patients are especially vulnerable to medication errors (ME) due to their severe clinical situation and the complexities of their management. To determine the frequency and characteristics of ME and identify shortcomings in the processes of medication management in an Intensive Care Unit. During a 3 months period, an observational prospective and randomized study was carried out in the ICU of a university hospital. Every step of patient's medication management (prescription, transcription, dispensation, preparation and administration) was evaluated by an external trained professional. Steps with higher frequency of ME and their therapeutic groups involved were identified. Medications errors were classified according to the National Coordinating Council for Medication Error Reporting and Prevention. In 52 of 124 patients evaluated, 66 ME were found in 194 drugs prescribed. In 34% of prescribed drugs, there was at least 1 ME during its use. Half of ME occurred during medication administration, mainly due to problems in infusion rates and schedule times. Antibacterial drugs had the highest rate of ME. We found a 34% rate of ME per drug prescribed, which is in concordance with international reports. The identification of those steps more prone to ME in the ICU, will allow the implementation of an intervention program to improve the quality and security of medication management.

  6. Evidence for Treatable Inborn Errors of Metabolism in a Cohort of 187 Greek Patients with Autism Spectrum Disorder (ASD

    Directory of Open Access Journals (Sweden)

    Martha eSpilioti

    2013-12-01

    Full Text Available We screened for the presence of inborn errors of metabolism (IEM in 187 children (105 males; 82 females, ages 4 -14 years old who presented with confirmed features of ASD. Twelve patients (7% manifested increased 3-hydroxyisovaleric acid (3-OH-IVA excretion in urine, and minor to significant improvement in autistic features was observed in seven patients following supplementation with biotin. Five diagnoses included: Lesch Nyhan syndrome (2, succinic semialdehyde dehydrogenase (SSADH deficiency (2 and phenylketonuria (1 (2.7%. Additional metabolic disturbances suggestive of IEMs included two patients whose increased urine 3-OH-IVA was accompanied by elevated methylcitrate and lactate in sera, and 30 patients that showed abnormal glucose-loading tests. In the latter group, 16/30 patients manifested increased sera beta hydroxybutyrate (b-OH-b production and 18/30 had a paradoxical increase of sera lactate. Six patients with elevated b-OH-b in sera showed improved autistic features following implementation of a ketogenic diet. Five patients showed decreased serum ketone body production with glucose loading. Twelve of 187 patients demonstrated nonspecific MRI pathology, while 25/187 had abnormal EEG findings. Finally, family history was positive for 22/187 patients (1st or 2nd degree relative with comparable symptomatology and consanguinity was documented for 12/187 patients. Our data provide evidence for a new biomarker (3-OH-IVA and novel treatment approaches in ASD patients.Concise 1 sentence take-home message: Detailed metabolic screening in a Greek cohort of autismspectrum disorder (ASD patients revealed biomarkers (urine 3-hydroxyisovaleric acid and serum b-OH-b in 7% (13/187 of patients for whom biotin supplementation or institution of a ketogenic diet resulted in mild to significant clinical improvement in autistic features.

  7. Cancer patients and positive sensory impressions in the hospital environment

    DEFF Research Database (Denmark)

    Timmermann, Connie; Uhrenfeldt, Lisbeth; Birkelund, Regner

    2013-01-01

    This study explores how cancer patients experience the meaning of positive sensory impressions in the hospital environment such as architecture, decoration and the interior. Data were obtained at a general hospital in Denmark by interviewing six cancer patients at two different wards. The analysis...... process was guided by the hermeneutical–phenomenological theory of interpretation as presented by the French philosopher Paul Ricoeur. Two main themes were identified: to preserve identity and positive thoughts and feelings. The participants experienced that positive sensory impressions in the hospital...... to recall some of their feelings of identity. This paper adds knowledge about how cancer patients experience sensory impressions in the hospital environment. An environment that provides homeliness and offers a view to nature seems to help some patients to preserve their identity. Furthermore, positive...

  8. 17 Smear positive pulmonary tuberculosis among HIV patients ...

    African Journals Online (AJOL)

    conducted in February 2009 to assess the effect of the level of CD4 lymphocyte ... development of smear positive pulmonary TB (PTB) among HIV patients before ..... (2000) Impact of combination antiretroviral therapy on the risk of tuberculosis.

  9. Effect of Body Mass Index on Magnitude of Setup Errors in Patients Treated With Adjuvant Radiotherapy for Endometrial Cancer With Daily Image Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Lilie L., E-mail: lin@uphs.upenn.edu [Department of Radiation Oncology, University of Pennsylvania School of Medicine, Philadelphia, PA (United States); Hertan, Lauren; Rengan, Ramesh; Teo, Boon-Keng Kevin [Department of Radiation Oncology, University of Pennsylvania School of Medicine, Philadelphia, PA (United States)

    2012-06-01

    Purpose: To determine the impact of body mass index (BMI) on daily setup variations and frequency of imaging necessary for patients with endometrial cancer treated with adjuvant intensity-modulated radiotherapy (IMRT) with daily image guidance. Methods and Materials: The daily shifts from a total of 782 orthogonal kilovoltage images from 30 patients who received pelvic IMRT between July 2008 and August 2010 were analyzed. The BMI, mean daily shifts, and random and systematic errors in each translational and rotational direction were calculated for each patient. Margin recipes were generated based on BMI. Linear regression and spearman rank correlation analysis were performed. To simulate a less-than-daily IGRT protocol, the average shift of the first five fractions was applied to subsequent setups without IGRT for assessing the impact on setup error and margin requirements. Results: Median BMI was 32.9 (range, 23-62). Of the 30 patients, 16.7% (n = 5) were normal weight (BMI <25); 23.3% (n = 7) were overweight (BMI {>=}25 to <30); 26.7% (n = 8) were mildly obese (BMI {>=}30 to <35); and 33.3% (n = 10) were moderately to severely obese (BMI {>=} 35). On linear regression, mean absolute vertical, longitudinal, and lateral shifts positively correlated with BMI (p = 0.0127, p = 0.0037, and p < 0.0001, respectively). Systematic errors in the longitudinal and vertical direction were found to be positively correlated with BMI category (p < 0.0001 for both). IGRT for the first five fractions, followed by correction of the mean error for all subsequent fractions, led to a substantial reduction in setup error and resultant margin requirement overall compared with no IGRT. Conclusions: Daily shifts, systematic errors, and margin requirements were greatest in obese patients. For women who are normal or overweight, a planning target margin margin of 7 to 10 mm may be sufficient without IGRT, but for patients who are moderately or severely obese, this is insufficient.

  10. Effect of Body Mass Index on Magnitude of Setup Errors in Patients Treated With Adjuvant Radiotherapy for Endometrial Cancer With Daily Image Guidance

    International Nuclear Information System (INIS)

    Lin, Lilie L.; Hertan, Lauren; Rengan, Ramesh; Teo, Boon-Keng Kevin

    2012-01-01

    Purpose: To determine the impact of body mass index (BMI) on daily setup variations and frequency of imaging necessary for patients with endometrial cancer treated with adjuvant intensity-modulated radiotherapy (IMRT) with daily image guidance. Methods and Materials: The daily shifts from a total of 782 orthogonal kilovoltage images from 30 patients who received pelvic IMRT between July 2008 and August 2010 were analyzed. The BMI, mean daily shifts, and random and systematic errors in each translational and rotational direction were calculated for each patient. Margin recipes were generated based on BMI. Linear regression and spearman rank correlation analysis were performed. To simulate a less-than-daily IGRT protocol, the average shift of the first five fractions was applied to subsequent setups without IGRT for assessing the impact on setup error and margin requirements. Results: Median BMI was 32.9 (range, 23–62). Of the 30 patients, 16.7% (n = 5) were normal weight (BMI <25); 23.3% (n = 7) were overweight (BMI ≥25 to <30); 26.7% (n = 8) were mildly obese (BMI ≥30 to <35); and 33.3% (n = 10) were moderately to severely obese (BMI ≥ 35). On linear regression, mean absolute vertical, longitudinal, and lateral shifts positively correlated with BMI (p = 0.0127, p = 0.0037, and p < 0.0001, respectively). Systematic errors in the longitudinal and vertical direction were found to be positively correlated with BMI category (p < 0.0001 for both). IGRT for the first five fractions, followed by correction of the mean error for all subsequent fractions, led to a substantial reduction in setup error and resultant margin requirement overall compared with no IGRT. Conclusions: Daily shifts, systematic errors, and margin requirements were greatest in obese patients. For women who are normal or overweight, a planning target margin margin of 7 to 10 mm may be sufficient without IGRT, but for patients who are moderately or severely obese, this is insufficient.

  11. X-ray radiography equipment for patients in standing position

    International Nuclear Information System (INIS)

    Snijder, J.G.N.

    1974-01-01

    X-ray radiography equipment suited for patients in standing position is described. The patient's body centre of mass is indicated by its vertical projection line appearing on the X-ray image. To that end, an X-ray absorbing wire is positioned through the centre of mass by means of an electrical signal acting on a servomotor and derived from the pressure on three non-colinear points in the foot plate through an analogue computer

  12. The representitativeness of patient position during the first treatment fractions

    DEFF Research Database (Denmark)

    Bertelsen, Anders; Nielsen, Morten; Westberg, Jonas

    2009-01-01

    BACKGROUND: During external radiotherapy daily or even weekly image verification of the patient position might be problematic due to the resulting workload. Therefore it has been customary to perform image verification only at the first treatment fraction. In this study it is investigated whether...... the patient position uncertainty at the initial three treatment fractions is representative for the uncertainty throughout the treatment course. METHODS: Seventy seven patients were treated using Elekta Synergy accelerators. The patients were immobilized during treatment by use of a customized VacFix bag...... and a mask of AquaPlast. Cone beam CT (CBCT) scans were performed at fractions 1, 2, and 3 and at the 10th and 20th treatment fractions. Displacements in patient position, translational and rotational, have been measured by an image registration of the CBCT and the planning CT scan. The displacements data...

  13. Patient positioning in radiotherapy based on surface imaging using time of flight cameras

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, M., E-mail: marlene.gilles@univ-brest.fr; Fayad, H.; Clement, J. F.; Bert, J.; Visvikis, D. [INSERM, UMR 1101, LaTIM, Brest 29609 (France); Miglierini, P. [Academic Radiotherapy Department, CHRU Morvan, Brest 29200 (France); Scheib, S. [Varian Medical Systems Imaging Laboratory GmbH, Baden-Daettwil 5405 (Switzerland); Cozzi, L. [Radiotherapy and Radiosurgery Department, Instituto Clinico Humanitas, Rozzano 20089 (Italy); Boussion, N.; Schick, U.; Pradier, O. [INSERM, UMR 1101, LaTIM, Brest 29609, France and Academic Radiotherapy Department, CHRU Morvan, Brest 29200 (France)

    2016-08-15

    Purpose: To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. Methods: A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, and head and neck cancer patients. Results: The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. Conclusions: The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).

  14. [Transposition errors during learning to reproduce a sequence by the right- and the left-hand movements: simulation of positional and movement coding].

    Science.gov (United States)

    Liakhovetskiĭ, V A; Bobrova, E V; Skopin, G N

    2012-01-01

    Transposition errors during the reproduction of a hand movement sequence make it possible to receive important information on the internal representation of this sequence in the motor working memory. Analysis of such errors showed that learning to reproduce sequences of the left-hand movements improves the system of positional coding (coding ofpositions), while learning of the right-hand movements improves the system of vector coding (coding of movements). Learning of the right-hand movements after the left-hand performance involved the system of positional coding "imposed" by the left hand. Learning of the left-hand movements after the right-hand performance activated the system of vector coding. Transposition errors during learning to reproduce movement sequences can be explained by neural network using either vector coding or both vector and positional coding.

  15. Performance of a video-image-subtraction-based patient positioning system

    International Nuclear Information System (INIS)

    Milliken, Barrett D.; Rubin, Steven J.; Hamilton, Russell J.; Johnson, L. Scott; Chen, George T.Y.

    1997-01-01

    Purpose: We have developed and tested an interactive video system that utilizes image subtraction techniques to enable high precision patient repositioning using surface features. We report quantitative measurements of system performance characteristics. Methods and Materials: Video images can provide a high precision, low cost measure of patient position. Image subtraction techniques enable one to incorporate detailed information contained in the image of a carefully verified reference position into real-time images. We have developed a system using video cameras providing orthogonal images of the treatment setup. The images are acquired, processed and viewed using an inexpensive frame grabber and a PC. The subtraction images provide the interactive guidance needed to quickly and accurately place a patient in the same position for each treatment session. We describe the design and implementation of our system, and its quantitative performance, using images both to measure changes in position, and to achieve accurate setup reproducibility. Results: Under clinical conditions (60 cm field of view, 3.6 m object distance), the position of static, high contrast objects could be measured with a resolution of 0.04 mm (rms) in each of two dimensions. The two-dimensional position could be reproduced using the real-time image display with a resolution of 0.15 mm (rms). Two-dimensional measurement resolution of the head of a patient undergoing treatment for head and neck cancer was 0.1 mm (rms), using a lateral view, measuring the variation in position of the nose and the ear over the course of a single radiation treatment. Three-dimensional repositioning accuracy of the head of a healthy volunteer using orthogonal camera views was less than 0.7 mm (systematic error) with an rms variation of 1.2 mm. Setup adjustments based on the video images were typically performed within a few minutes. The higher precision achieved using the system to measure objects than to reposition

  16. Pattern of neuropsychological performance among HIV positive patients in Uganda

    Directory of Open Access Journals (Sweden)

    Parsons Thomas D

    2007-04-01

    Full Text Available Abstract Background Few studies have examined cognitive functioning of HIV positive patients in sub-Saharan Africa. It cannot be assumed that HIV positive patients in Africa exhibit the same declines as patients in high-resource settings, since there are differences that may influence cognitive functioning including nutrition, history of concomitant disease, and varying HIV strains, among other possibilities. Part of the difficulty of specifying abnormalities in neuropsychological functioning among African HIV positive patients is that there are no readily available African normative databases. The purpose of the current study was to evaluate the pattern of neuropsychological performance in a sample of HIV positive patients in comparison to HIV negative control subjects in Uganda. Methods The neuropsychological test scores of 110 HIV positive patients (WHO Stage 2, n = 21; WHO Stage 3, n = 69; WHO Stage 4, n = 20 were contrasted with those of 100 control subjects on measures of attention/concentration, mental flexibility, learning/memory, and motor functioning. Results Analysis of covariance (ANCOVA revealed significant group differences on measures of verbal learning and memory, speed of processing, attention and executive functioning between HIV seropositive and seronegative subjects. Conclusion Ugandan patients with HIV demonstrated relative deficits on measures of verbal learning and memory, speed of processing, attention, and executive functioning compared to HIV negative controls. These results from a resource limited region where clades A and D are prevalent are consistent with previous findings in the developed world where clade B predominates.

  17. Beam-centric algorithm for pretreatment patient position correction in external beam radiation therapy

    International Nuclear Information System (INIS)

    Bose, Supratik; Shukla, Himanshu; Maltz, Jonathan

    2010-01-01

    Purpose: In current image guided pretreatment patient position adjustment methods, image registration is used to determine alignment parameters. Since most positioning hardware lacks the full six degrees of freedom (DOF), accuracy is compromised. The authors show that such compromises are often unnecessary when one models the planned treatment beams as part of the adjustment calculation process. The authors present a flexible algorithm for determining optimal realizable adjustments for both step-and-shoot and arc delivery methods. Methods: The beam shape model is based on the polygonal intersection of each beam segment with the plane in pretreatment image volume that passes through machine isocenter perpendicular to the central axis of the beam. Under a virtual six-DOF correction, ideal positions of these polygon vertices are computed. The proposed method determines the couch, gantry, and collimator adjustments that minimize the total mismatch of all vertices over all segments with respect to their ideal positions. Using this geometric error metric as a function of the number of available DOF, the user may select the most desirable correction regime. Results: For a simulated treatment plan consisting of three equally weighted coplanar fixed beams, the authors achieve a 7% residual geometric error (with respect to the ideal correction, considered 0% error) by applying gantry rotation as well as translation and isocentric rotation of the couch. For a clinical head-and-neck intensity modulated radiotherapy plan with seven beams and five segments per beam, the corresponding error is 6%. Correction involving only couch translation (typical clinical practice) leads to a much larger 18% mismatch. Clinically significant consequences of more accurate adjustment are apparent in the dose volume histograms of target and critical structures. Conclusions: The algorithm achieves improvements in delivery accuracy using standard delivery hardware without significantly increasing

  18. Condom Use Errors and Problems: A Comparative Study of HIV-Positive Versus HIV-Negative Young Black Men Who Have Sex With Men.

    Science.gov (United States)

    Crosby, Richard; Mena, Leandro; Yarber, William L; Graham, Cynthia A; Sanders, Stephanie A; Milhausen, Robin R

    2015-11-01

    To describe self-reported frequencies of selected condom use errors and problems among young (age, 15-29 years) black men who have sex with men (YBMSM) and to compare the observed prevalence of these errors/problems by HIV serostatus. Between September 2012 October 2014, electronic interview data were collected from 369 YBMSM attending a federally supported sexually transmitted infection clinic located in the southern United States. Seventeen condom use errors and problems were assessed. χ(2) Tests were used to detect significant differences in the prevalence of these 17 errors and problems between HIV-negative and HIV-positive men. The recall period was the past 90 days. The overall mean (SD) number of errors/problems was 2.98 (2.29). The mean (SD) for HIV-negative men was 2.91 (2.15), and the mean (SD) for HIV-positive men was 3.18 (2.57). These means were not significantly different (t = 1.02, df = 367, P = 0.31). Only 2 significant differences were observed between HIV-negative and HIV-positive men. Breakage (P = 0.002) and slippage (P = 0.005) were about twice as likely among HIV-positive men. Breakage occurred for nearly 30% of the HIV-positive men compared with approximately 15% among HIV-negative men. Slippage occurred for approximately 16% of the HIV-positive men compared with approximately 9% among HIV-negative men. A need exists to help YBMSM acquire the skills needed to avert breakage and slippage issues that could lead to HIV transmission. Beyond these 2 exceptions, condom use errors and problems were ubiquitous in this population regardless of HIV serostatus. Clinic-based intervention is warranted for these young men, including education about correct condom use and provision of free condoms and long-lasting lubricants.

  19. Family correlates of depression among hiv positive patients ...

    African Journals Online (AJOL)

    Background information: HIV infection may impact negatively on family relationship and vice versa. Members of the family of HIV positive patients may become frustrated because of the stigma of having a family member with HIV infection, and the burden of having to care for the patient. This can result into the family ...

  20. Quantitative analysis of the errors positioning of a multi leaf collimator for volumetric arcoterapia treatments; Analisis cuantitativo de los errores de posicionamiento de un colimador multilaminas para tratamientos de arcoterapia volumetrica

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Gonzalez, N.; Garcia Repiso, S.; Martin Rincon, C.; Cons Perez, N.; Saez Beltran, M.; Delgado Aparicio, J. M.; Perez alvarez, M. E.; Verde Velasco, J. M.; Ramos Pacho, J. A.; Sena Espinel, E. de

    2013-07-01

    The precision in the positioning of the multi leaf collimation system of a linear accelerator is critical, especially in treatments of IMRT, where small mistakes can cause relevant dosimetry discrepancies regarding the calculated plan. To assess the accuracy and repeatability of the blades positioning can be used controls, including the one known as fence test whose image pattern allows you to find anomalies in a visual way. The objective of this study is to develop a method which allows to quantify the positioning errors of the multi leaf collimator from this test. (Author)

  1. Croatian Recommendations for Dialysis of HIV-Positive Patients

    Directory of Open Access Journals (Sweden)

    Gulin Marijana

    2016-06-01

    Full Text Available Human immunodeficiency virus (HIV infection may be associated with renal impairment since about 0.4% of all HIV-positive patients develop end-stage renal disease. The share of patients with HIV infection in hemodialysis centers throughout the world ranges from 0.3% to as high as 38%. In Croatia, renal replacement therapy was needed by 1% of all the HIV-positive patients from 1985 until the end of 2014. Healthcare professionals (HP should be aware of the risks of occupational exposure to blood-borne infections in their daily work. Performing dialysis in HIV-positive patients increases the risk of exposure to HIV during the extracorporeal circulation of the infected blood. However, post-exposure prophylaxis (PEP with effective antiretroviral drugs significantly reduces the risk of infection after occupational exposure. On behalf of the Croatian Society of Nephrology, Dialysis and Transplantation, the authors of this paper have proposed recommendations for the management of HIVpositive patients on dialysis, which aim to prevent the transmission of HIV among patients and HPs. The important recommendations include the following: 1. when the need arises, it is necessary to provide HIV-positive patients with dialysis in the vicinity of their place of residence. 2. HIV-positive patients should be dialyzed with a separate hemodialysis machine in an isolated area. Alternatively, they can be dialyzed in an area for the hemodialysis of HCV-positive and/or HBVpositive patients. 3. Specialized and trained personnel should be provided during the hemodialysis procedure, together with strict compliance with the standard precautions for the prevention of blood-borne infections. 4. There should be a good and prompt cooperation with the National Referral Center for HIV infection.

  2. Change for the better: an innovative model of care delivering positive patient and workforce outcomes.

    Science.gov (United States)

    Cann, Tina; Gardner, Anne

    2012-01-01

    To evaluate patient and workforce outcomes following the implementation of the Practice Partnership Model of Care. Pre-test-post-test design. A 29-bed surgical ward at a tertiary-level regional hospital. Summary de-identified data from all patients and ward nursing staff in the study period. The Practice Partnership Model of Care has four main components: working in partnership; clinical handover at the bedside; comfort rounds; and environmental modifications. These reflect patient-centered and quality focused initiatives and use a total quality improvement framework that aims to transform care at the bedside. Patient outcomes: changes in patient safety (measured by numbers of medication errors and patient falls); satisfaction with care (use of the call bell system, number of complaints and compliments). Workforce outcomes: changes in staff satisfaction (measured through staff sick leave). A statistically significant reduction in use of nurse call bells (p=<0.001) post-implementation. Medication errors and patient falls reduced, with an overall reduction of 4% in staff sick leave. The Practice Partnership Model of Care positively affected patient and workforce outcomes, suggesting further exploration of this model in other hospital contexts is warranted.

  3. Primary care physicians' willingness to disclose oncology errors involving multiple providers to patients.

    Science.gov (United States)

    Mazor, Kathleen; Roblin, Douglas W; Greene, Sarah M; Fouayzi, Hassan; Gallagher, Thomas H

    2016-10-01

    Full disclosure of harmful errors to patients, including a statement of regret, an explanation, acceptance of responsibility and commitment to prevent recurrences is the current standard for physicians in the USA. To examine the extent to which primary care physicians' perceptions of event-level, physician-level and organisation-level factors influence intent to disclose a medical error in challenging situations. Cross-sectional survey containing two hypothetical vignettes: (1) delayed diagnosis of breast cancer, and (2) care coordination breakdown causing a delayed response to patient symptoms. In both cases, multiple physicians shared responsibility for the error, and both involved oncology diagnoses. The study was conducted in the context of the HMO Cancer Research Network Cancer Communication Research Center. Primary care physicians from three integrated healthcare delivery systems located in Washington, Massachusetts and Georgia; responses from 297 participants were included in these analyses. The dependent variable intent to disclose included intent to provide an apology, an explanation, information about the cause and plans for preventing recurrences. Independent variables included event-level factors (responsibility for the event, perceived seriousness of the event, predictions about a lawsuit); physician-level factors (value of patient-centred communication, communication self-efficacy and feelings about practice); organisation-level factors included perceived support for communication and time constraints. A majority of respondents would not fully disclose in either situation. The strongest predictors of disclosure were perceived personal responsibility, perceived seriousness of the event and perceived value of patient-centred communication. These variables were consistently associated with intent to disclose. To make meaningful progress towards improving disclosure; physicians, risk managers, organisational leaders, professional organisations and

  4. Analysis of liquid medication dose errors made by patients and caregivers using alternative measuring devices.

    Science.gov (United States)

    Ryu, Gyeong Suk; Lee, Yu Jeung

    2012-01-01

    Patients use several types of devices to measure liquid medication. Using a criterion ranging from a 10% to 40% variation from a target 5 mL for a teaspoon dose, previous studies have found that a considerable proportion of patients or caregivers make errors when dosing liquid medication with measuring devices. To determine the rate and magnitude of liquid medication dose errors that occur with patient/caregiver use of various measuring devices in a community pharmacy. Liquid medication measurements by patients or caregivers were observed in a convenience sample of community pharmacy patrons in Korea during a 2-week period in March 2011. Participants included all patients or caregivers (N = 300) who came to the pharmacy to buy over-the-counter liquid medication or to have a liquid medication prescription filled during the study period. The participants were instructed by an investigator who was also a pharmacist to select their preferred measuring devices from 6 alternatives (etched-calibration dosing cup, printed-calibration dosing cup, dosing spoon, syringe, dispensing bottle, or spoon with a bottle adapter) and measure a 5 mL dose of Coben (chlorpheniramine maleate/phenylephrine HCl, Daewoo Pharm. Co., Ltd) syrup using the device of their choice. The investigator used an ISOLAB graduated cylinder (Germany, blue grad, 10 mL) to measure the amount of syrup dispensed by the study participants. Participant characteristics were recorded including gender, age, education level, and relationship to the person for whom the medication was intended. Of the 300 participants, 257 (85.7%) were female; 286 (95.3%) had at least a high school education; and 282 (94.0%) were caregivers (parent or grandparent) for the patient. The mean (SD) measured dose was 4.949 (0.378) mL for the 300 participants. In analysis of variance of the 6 measuring devices, the greatest difference from the 5 mL target was a mean 5.552 mL for 17 subjects who used the regular (etched) dosing cup and 4

  5. Improvement in Detection of Wrong-Patient Errors When Radiologists Include Patient Photographs in Their Interpretation of Portable Chest Radiographs.

    Science.gov (United States)

    Tridandapani, Srini; Olsen, Kevin; Bhatti, Pamela

    2015-12-01

    This study was conducted to determine whether facial photographs obtained simultaneously with radiographs improve radiologists' detection rate of wrong-patient errors, when they are explicitly asked to include the photographs in their evaluation. Radiograph-photograph combinations were obtained from 28 patients at the time of portable chest radiography imaging. From these, pairs of radiographs were generated. Each unique pair consisted of one new and one old (comparison) radiograph. Twelve pairs of mismatched radiographs (i.e., pairs containing radiographs of different patients) were also generated. In phase 1 of the study, 5 blinded radiologist observers were asked to interpret 20 pairs of radiographs without the photographs. In phase 2, each radiologist interpreted another 20 pairs of radiographs with the photographs. Radiologist observers were not instructed about the purpose of the photographs but were asked to include the photographs in their review. The detection rate of mismatched errors was recorded along with the interpretation time for each session for each observer. The two-tailed Fisher exact test was used to evaluate differences in mismatch detection rates between the two phases. A p value of error detection rates without (0/20 = 0%) and with (17/18 = 94.4%) photographs were different (p = 0.0001). The average interpretation times for the set of 20 radiographs were 26.45 (SD 8.69) and 20.55 (SD 3.40) min, for phase 1 and phase 2, respectively (two-tailed Student t test, p = 0.1911). When radiologists include simultaneously obtained photographs in their review of portable chest radiographs, there is a significant improvement in the detection of labeling errors. No statistically significant difference in interpretation time was observed. This may lead to improved patient safety without affecting radiologists' throughput.

  6. Measuring uncertainty in dose delivered to the cochlea due to setup error during external beam treatment of patients with cancer of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Yan, M.; Lovelock, D.; Hunt, M.; Mechalakos, J.; Hu, Y.; Pham, H.; Jackson, A., E-mail: jacksona@mskcc.org [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York 10065 (United States)

    2013-12-15

    Purpose: To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. Methods: Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patients were treated with conventional fractionation using an IMRT dose painting technique, most with 33 fractions. Weekly radiographic imaging was used to correct the patient setup. The authors used rigid registration of the planning CT and Cone Beam CT scans to find the translational and rotational setup errors, and the spatial setup errors of the cochlea. The planning CT was rotated and translated such that the cochlea positions match those seen in the cone beam scans, cochlea doses were recalculated and fractional doses accumulated. Uncertainties in the positions and cumulative doses of the cochlea were calculated with and without setup adjustments from radiographic imaging. Results: The mean setup error of the cochlea was 0.04 ± 0.33 or 0.06 ± 0.43 cm for RL, 0.09 ± 0.27 or 0.07 ± 0.48 cm for AP, and 0.00 ± 0.21 or −0.24 ± 0.45 cm for SI with and without radiographic imaging, respectively. Setup with radiographic imaging reduced the standard deviation of the setup error by roughly 1–2 mm. The uncertainty of the cochlea dose depends on the treatment plan and the relative positions of the cochlea and target volumes. Combining results for the left and right cochlea, the authors found the accumulated uncertainty of the cochlea dose per fraction was 4.82 (0.39–16.8) cGy, or 10.1 (0.8–32.4) cGy, with and without radiographic imaging, respectively; the percentage uncertainties relative to the planned doses were 4.32% (0.28%–9.06%) and 10.2% (0.7%–63.6%), respectively. Conclusions: Patient setup error introduces uncertainty in the position of the cochlea during radiation treatment. With the assistance of radiographic imaging during setup

  7. Liver transplantation in HIV-positive patients: the position of the Brazilian groups.

    Science.gov (United States)

    Brandão, Ajacio Bandeira de Mello; Mariante-Neto, Guilherme

    2005-01-01

    Patients infected with the human immunodeficiency virus (HIV) have generally been excluded from consideration for liver transplantation. Recent advances in the management and prognosis of these patients suggest that this policy must be reevaluated. To identify the current position of Brazilian transplant centers concerning liver transplantation in asymptomatic HIV-infected patients with end-stage liver disease. A structured questionnaire was submitted by e-mail to Brazilian groups who perform liver transplantation and were active in late 2003, according to the Brazilian Association of Organ Transplantation. Of the 53 active groups, 30 e-mail addresses have been found of professionals working in 41 of these groups. Twenty-one responses (70%) were obtained. Most of the professionals (62%) reported that they do not include HIV-infected patients in waiting lists for transplants, primarily on account of the limited world experience. They also reported, however, that this issue will soon be discussed by the group. Those who accept these patients usually follow the guidelines provided by the literature: patients must fulfill the same inclusion criteria as the other patients with end-stage liver diseases, present low or undetectable HIV viral load, and a CD4 count above 250/mm3. They reported that there are 10 HIV-infected patients in waiting list and that only one patient has received a liver transplant in the country. Most centers do not accept in waiting lists for liver transplantation patients with HIV infection, even asymptomatic ones. However, advances in the management of HIV-infected patients suggest that this policy must be reevaluated. In Brazil, there is practically no experience in liver transplantation in HIV-positive patients.

  8. The patient position for PNL: does it matter?

    Science.gov (United States)

    Cracco, Cecilia Maria; Scoffone, Cesare Marco; Poggio, Massimiliano; Scarpa, Roberto Mario

    2010-03-01

    Currently, PNL is the treatment of choice for large and/or otherwise complex urolithiasis. PNL was initially performed with the patient in a supine-oblique position, but later on the prone position became the conventional one for habit and handiness. The prone position provides a larger area for percutaneous renal access, a wider space for instrument manipulation, and a claimed lower risk of splanchnic injury. Nonetheless, it implies important anaesthesiological risks, including circulatory, haemodynamic, and ventilatory difficulties; need of several nurses to be present for intraoperative changes of the decubitus in case of simultaneous retrograde instrumentation of the ureter, implying evident risks related to pressure points; an increased radiological hazard to the urologist's hands; patient discomfort. To overcome these drawbacks, various safe and effective changes in patient positioning for PNL have been proposed over the years, including the reverse lithotomy position, the prone split-leg position, the lateral decubitus, the supine position, and the Galdakao-modified supine Valdivia (GMSV) position. Among these, the GMSV position is safe and effective, and seems profitable and ergonomic. It allows optimal cardiopulmonary control during general anaesthesia; an easy puncture of the kidney; a reduced risk of colonic injury; simultaneous antero-retrograde approach to the renal cavities (PNL and retrograde ureteroscopy = ECIRS, Endoscopic Combined IntraRenal Surgery), with no need of intraoperative repositioning of the anaesthetized patient, less need for nurses in the operating room, less occupational risk due to shifting of heavy loads, less risk of pressure injuries related to inaccurate repositioning, and reduced duration of the procedure; facilitated spontaneous evacuation of stone fragments; a comfortable sitting position and a restrained X-ray exposure of the hands for the urologist. But, first of all, GMSV position fully supports a new comprehensive

  9. Delay in treatment seeking of smear positive tuberculous patients

    International Nuclear Information System (INIS)

    Bhatti, A.T.; Zahid, M.

    2010-01-01

    To assess and identify the causes and circumstances leading to delays in health seeking and diagnosis of tuberculosis patients as they often present with advance disease resulting in increased morbidity and mortality. Settings Department of Tuberculosis, DOTS clinic DHQ Hospital, Vehari. Methodology One (author) inspiration diagnosed smear positive pulmonary tuberculosis patients were included. Information was gathered through interviews and from TB-01 card. Results Maximum patients were in age group of 16-40 years. Median patient delay was 4-6 months; jobless, homeless personnel had longer delay. The main reason for delay was that the symptoms were not considered serious enough. Delay in presentation of smear positive cases may be due to the lack of awareness of patients and the incompetence of some health workers. Training and supervision of staff and awareness campaigns targeted at the population and involvement of private sector will improve TB control in Vehari. (author)

  10. Erro médico em pacientes hospitalizados Medical errors in hospitalized patients

    Directory of Open Access Journals (Sweden)

    Manoel de Carvalho

    2002-01-01

    sistema, e encarados como oportunidade de revisão do processo e aprimoramento da assistência prestada ao paciente.Objective: to review the current literature and to discuss medical errors in hospitalized patients emphasizing its incidence, predisposing factors and prevention mechanism. Special attention is given to medication errors and adverse drug events in newborn infants and pediatric patients. Sources: bibliographic review of the current literature through electronic search in Medline data-base, with selection of the most relevant articles. Summary of the findings: even though most medical errors are not reported, it is important to notice that its incidence is greater than previously assumed. In the USA, approximately one million of patients/year are victims of medical errors and adverse drug events. Today, deaths resulting from these episodes are the fourth cause of mortality in the USA. In neonatal and pediatric intensive care units, where the complexity and frequency of technical procedures are high, medical errors are frequent. Fifteen percent of all admissions to a neonatal intensive care unit is followed by medical errors. Most of these errors occur during night shifts and include incorrect administration of drugs (35% and errors regarding the interpretation of medical prescription (26%. Environmental factors (noise, heat, psychological factors (anxiety, stress and physiologic factors (fatigue, absence of sleep contribute to the occurrence of errors. Recent study shows that after working 24 hours without sleeping, the performance of a health professional is similar to a legally drunk person (serum alcohol level > 0.08%. Conclusions: errors are part of human behavior. The prevention of errors should include a careful review of the organizational system. Medical errors should be seen as an opportunity to change or re-structure the system and to improve the quality of health care delivered and patient safety.

  11. Analysis of Factors and Medical Errors Involved in Patient Complaints in a European Emergency Department

    Directory of Open Access Journals (Sweden)

    Pauline Haroutunian

    2017-12-01

    Full Text Available Introduction: Patients’ complaints from Emergency Departments (ED are frequent and can be used as a quality assurance indicator. Objective: Factors contributing to patients’ complaints (PCs in the emergency department were analyzed.  Methods: It was a retrospective cohort study, the qualitative variables of patients’ complaints visiting ED of a university hospital were compared with Chi-Square and t test tests. Results: Eighty-five PC were analyzed. The factors contributing to PC were: communication (n=26, length of stay (LOS (n=24, diagnostic errors (n=21, comfort and privacy issues (n=7, pain management (n=6, inappropriate treatment (n=6, delay of care and billing issues (n=3. PCs were more frequent when patients were managed by residents, during night shifts, weekends, Saturdays, Mondays, January and June. Moreover, the factors contributing to diagnostic errors were due to poor communication, non-adherence to guidelines and lack of systematic proofreading of X-rays. In 98% of cases, disputes were resolved by apology and explanation and three cases resulted in financial compensation. Conclusion: Poor communication, LOS and medical errors are factors contributing to PCs. Improving communication, resolving issues leading to slow health care provision, adequate staffing and supervision of trainees may reduce PCs.

  12. Parenteral nutrition in patients with inborn errors of metabolism - a therapeutic problem.

    Science.gov (United States)

    Kaluzny, L; Szczepanik, M; Siwinska-Mrozek, Z; Borkowska-Klos, M; Cichy, W; Walkowiak, J

    2014-06-01

    Parenteral nutrition is now a standard part of supportive treatment in pediatric departments. We describe four cases in which parenteral nutrition was extremely difficult due to coincidence with inborn errors of metabolism. The first two cases was fatty acid beta-oxidation disorders associated with necrotizing enterocolitis and congenital heart disease. Thus, limitations of intravenous lipid intake made it difficult to maintain a good nutritional status. The third case was phenylketonuria associated with a facial region tumour (rhabdomyosarcoma), in which parenteral nutrition was complicated because of a high phenylalanine content in the amino acid formulas for parenteral nutrition. The fourth patient was a child with late-diagnosed tyrosinemia type 1, complicated with encephalopathy - during intensive care treatment the patient needed nutritional support, including parenteral nutrition - we observed amino acid formula problems similar to those in the phenylketonuria patient. Parenteral nutrition in children with inborn errors of metabolism is a rare, but very important therapeutic problem. Total parenteral nutrition formulas are not prepared for this group of diseases.

  13. Development of an iterative reconstruction method to overcome 2D detector low resolution limitations in MLC leaf position error detection for 3D dose verification in IMRT

    NARCIS (Netherlands)

    Visser, Ruurd; J., Godart; Wauben, D.J.L.; Langendijk, J.; van 't Veld, A.A.; Korevaar, E.W.

    2016-01-01

    The objective of this study was to introduce a new iterative method to reconstruct multi leaf collimator (MLC) positions based on low resolution ionization detector array measurements and to evaluate its error detection performance. The iterative reconstruction method consists of a fluence model, a

  14. Verification of the positioning of radiotherapy patients with two webcams

    Energy Technology Data Exchange (ETDEWEB)

    Píriz, Gustavo; Lucas, Manuela; Bertini, Diego; Doldán, Raquel, E-mail: oncosur@oncosur.com.uy [Oncosur, Florida (Uruguay); Banguero, Yolma; Frederico, Marcel, E-mail: ybanguero@cin.edu.uy [Unidad de Radioproteccion, Centro de Invetigaciones Nucleares, Universidad de la Republica, Montevideo (Uruguay)

    2017-07-01

    In radiotherapy, high doses are given to the volumes that are to be irradiated and the organs at risk have to be protected. This implies putting great care into the patient's position and the reproducibility of the patient during all treatment sections. In our center the position during the treatment is bounded with thermoplastic masks, and the reproducibility between different sections is checked with daily photos during the treatment. For the evaluation of the photos we stick spheres of 8 mm of diameter to the fixing masks. We captured photos with two webcams that are less than 90 cm from the isocenter, one from the left and the other from the right. A quick visual evaluation allows you to detect changes in the position of the radius of the sphere. We present an absolute calibration methodology of the position of the sphere with two webcams. (author)

  15. An electromechanical, patient positioning system for head and neck radiotherapy

    Science.gov (United States)

    Ostyn, Mark; Dwyer, Thomas; Miller, Matthew; King, Paden; Sacks, Rachel; Cruikshank, Ross; Rosario, Melvin; Martinez, Daniel; Kim, Siyong; Yeo, Woon-Hong

    2017-09-01

    In cancer treatment with radiation, accurate patient setup is critical for proper dose delivery. Improper arrangement can lead to disease recurrence, permanent organ damage, or lack of disease control. While current immobilization equipment often helps for patient positioning, manual adjustment is required, involving iterative, time-consuming steps. Here, we present an electromechanical robotic system for improving patient setup in radiotherapy, specifically targeting head and neck cancer. This positioning system offers six degrees of freedom for a variety of applications in radiation oncology. An analytical calculation of inverse kinematics serves as fundamental criteria to design the system. Computational mechanical modeling and experimental study of radiotherapy compatibility and x-ray-based imaging demonstrates the device feasibility and reliability to be used in radiotherapy. An absolute positioning accuracy test in a clinical treatment room supports the clinical feasibility of the system.

  16. Prostate immobilization can be achieved with patient positioning

    International Nuclear Information System (INIS)

    Huang, David T.; Silverman, Larry N.; Tercilla, Oscar F.; Lutz, Stephen T.

    1995-01-01

    Purpose/Objective: With advances in 3D conformal therapy, daily variation in the position of the prostate poses increasing problems for radiation oncologists. In this study we attempt to define the optimal treatment position for patients with prostate cancer by measuring the range of movement of the prostate. Materials and Methods: Ten patients with biopsy proven adenocarcinoma of the prostate underwent prone and supine CT scans with IV and oral contrast. Foley catheters (FC) were placed in the urinary bladder, and renograffin was used to make the balloon radiopaque. AP/PA and lateral radiographs were taken for patients in the supine and prone position with either empty bladder (EB) or partially filled bladder (PFB, containing 60 cc of contrast medium). Measurements were taken from the Foley catheter (represents prostatic urethra), to the anterior rectal wall and pubic symphysis (PS). The rectal gas pattern was analyzed to evaluate the rectum-sparing effect. The false table top was not used. Results: For radiographs taken in the supine position, the FC was located 1.4 ± 0.5 cm from the PS in the case of PFB versus EB. In the prone position the variation was significantly less, with an increase in FC to PS distance of only 0.5 ± 0.3 cm for a PFB versus EB. The rectal gas pattern was also noted to vary, with a more expanded and rounded shape in the prone position. Conclusion: Most institutions treat patients with prostate cancer in the supine position. The previous rationale for treatment in the prone position has been small bowel sparing. Here, however, we show that prone treatment also minimizes the motion of the prostate. With less posterior margin required, 3D conformal treatment could be delivered with an additional 30-50% rectal sparing

  17. The introduction of an acute physiological support service for surgical patients is an effective error reduction strategy.

    Science.gov (United States)

    Clarke, D L; Kong, V Y; Naidoo, L C; Furlong, H; Aldous, C

    2013-01-01

    Acute surgical patients are particularly vulnerable to human error. The Acute Physiological Support Team (APST) was created with the twin objectives of identifying high-risk acute surgical patients in the general wards and reducing both the incidence of error and impact of error on these patients. A number of error taxonomies were used to understand the causes of human error and a simple risk stratification system was adopted to identify patients who are particularly at risk of error. During the period November 2012-January 2013 a total of 101 surgical patients were cared for by the APST at Edendale Hospital. The average age was forty years. There were 36 females and 65 males. There were 66 general surgical patients and 35 trauma patients. Fifty-six patients were referred on the day of their admission. The average length of stay in the APST was four days. Eleven patients were haemo-dynamically unstable on presentation and twelve were clinically septic. The reasons for referral were sepsis,(4) respiratory distress,(3) acute kidney injury AKI (38), post-operative monitoring (39), pancreatitis,(3) ICU down-referral,(7) hypoxia,(5) low GCS,(1) coagulopathy.(1) The mortality rate was 13%. A total of thirty-six patients experienced 56 errors. A total of 143 interventions were initiated by the APST. These included institution or adjustment of intravenous fluids (101), blood transfusion,(12) antibiotics,(9) the management of neutropenic sepsis,(1) central line insertion,(3) optimization of oxygen therapy,(7) correction of electrolyte abnormality,(8) correction of coagulopathy.(2) CONCLUSION: Our intervention combined current taxonomies of error with a simple risk stratification system and is a variant of the defence in depth strategy of error reduction. We effectively identified and corrected a significant number of human errors in high-risk acute surgical patients. This audit has helped understand the common sources of error in the general surgical wards and will inform

  18. Pregnancy in HIV-Positive Patients: Effects on Vaginal Flora

    Directory of Open Access Journals (Sweden)

    Cristina Vallone

    2012-01-01

    Full Text Available A high proportion of HIV-infected pregnant women present pathogenic organisms in their lower genital tract. This has been associated with the development of postpartum morbility, HIV transmission to the partner and offspring, and other gynaecological conditions, such as cervical dysplasia or cancer. Vaginal flora alterations can range from 47% in Western countries to 89% in Africa in pregnant HIV-positive patients, much higher than about 20% of the general population. Pathogen organism retrieval is high. As peripartum complications due to vaginal infections seem higher in HIV-positive patients, accurate investigation and treatment of such infections are strongly mandatory.

  19. Patient positioning and immobilization in static and dynamic adaptive radiotherapy: an integral part of IGRT

    International Nuclear Information System (INIS)

    Oinam, Arun S.

    2016-01-01

    Radiotherapy treatment deals with different varieties of treatment procedures depending on type and stages of tumors. These treatments are grossly classified into palliative curative treatment. Immobilizations used in this treatment are designed with respect to this classification as well as the techniques. With the improvements in imaging technology used in Radiotherapy, patient position set up margin can be reduced as compared to the conventional radiotherapy. Still immobilization in patient position setup has been an integral part of Image Guided Radiotherapy (lGRT) and Stereotactic Radio Surgery (SRS) and Radiotherapy (SRT). Immobilization used in this technique should produce a minimum attenuation of radiation beam as well as positioning comfort and this will enhance the reproducibility for the daily position setup and immobilize the patient during the treatment. Advanced dose delivery technique like Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Radiotherapy (VMAT) can do differential dose sculpting around and inside the irregular shape different target volumes while minimizing the dose to the surrounding organs at risk. A small positional error may produce the mistreatment of target and exposure of organs at risk beyond the acceptable dose limits. Such a potential positional error can be reduced if different varieties of good immobilizing devices are properly utilized. The immobilization used in the treatment of Head and Neck and Cranial tumor can produce better immobilization as compared to abdominal and pelvic tumors which are forced to move by the inability to control movements of lung and heart as well as the very large flabby tissues which are attached skeleton bones

  20. Reversible Thrombocytopenia after Gabapentin in an HIV-Positive Patient

    Directory of Open Access Journals (Sweden)

    Mohammed Basith

    2018-01-01

    Full Text Available Gabapentin has become increasingly used in psychiatric practice specifically for anxiety disorders. Even though gabapentin is not approved by the US Food and Drug Administration to treat anxiety, physicians sometimes use it as an alternative to benzodiazepines in patients with a history of substance abuse. Gabapentin is also prescribed when individuals are at risk of thrombocytopenia which is not considered a side effect. Among patients at risk of thrombocytopenia are those positive for human immunodeficiency virus (HIV. Here we present a case of an HIV-positive man who presented for inpatient psychiatric care with severe anxiety and a history of alcohol and benzodiazepine abuse. In this patient, gabapentin worsened thrombocytopenia after repeated exposure to this medication. We suggest caution when considering gabapentin for patients with preexisting low platelet counts, as there seems to be a risk for worsening thrombocytopenia with this antiepileptic in the presence of HIV infection.

  1. Preparing Emergency Medicine Residents to Disclose Medical Error Using Standardized Patients

    Directory of Open Access Journals (Sweden)

    Carmen N. Spalding

    2017-12-01

    Full Text Available Introduction Emergency Medicine (EM is a unique clinical learning environment. The American College of Graduate Medical Education Clinical Learning Environment Review Pathways to Excellence calls for “hands-on training” of disclosure of medical error (DME during residency. Training and practicing key elements of DME using standardized patients (SP may enhance preparedness among EM residents in performing this crucial skill in a clinical setting. Methods This training was developed to improve resident preparedness in DME in the clinical setting. Objectives included the following: the residents will be able to define a medical error; discuss ethical and professional standards of DME; recognize common barriers to DME; describe key elements in effective DME to patients and families; and apply key elements during a SP encounter. The four-hour course included didactic and experiential learning methods, and was created collaboratively by core EM faculty and subject matter experts in conflict resolution and healthcare simulation. Educational media included lecture, video exemplars of DME communication with discussion, small group case-study discussion, and SP encounters. We administered a survey assessing for preparedness in DME pre-and post-training. A critical action checklist was administered to assess individual performance of key elements of DME during the evaluated SP case. A total of 15 postgraduate-year 1 and 2 EM residents completed the training. Results After the course, residents reported increased comfort with and preparedness in performing several key elements in DME. They were able to demonstrate these elements in a simulated setting using SP. Residents valued the training, rating the didactic, SP sessions, and overall educational experience very high. Conclusion Experiential learning using SP is effective in improving resident knowledge of and preparedness in performing medical error disclosure. This educational module can be adapted

  2. Cognitive Moderators of Children's Adjustment to Stressful Divorce Events: The Role of Negative Cognitive Errors and Positive Illusions.

    Science.gov (United States)

    Mazur, Elizabeth; Wolchik, Sharlene A.; Virdin, Lynn; Sandler, Irwin N.; West, Stephen G.

    1999-01-01

    Examined whether children's cognitive biases moderated impact of stressful divorce-related events on adjustment in 9- to 12-year olds. Found that endorsing negative cognitive errors for hypothetical divorce events moderated relations between stressful divorce events and self- and maternal-reports of internalizing and externalizing symptoms for…

  3. Establishment and application of medication error classification standards in nursing care based on the International Classification of Patient Safety

    Directory of Open Access Journals (Sweden)

    Xiao-Ping Zhu

    2014-09-01

    Conclusion: Application of this classification system will help nursing administrators to accurately detect system- and process-related defects leading to medication errors, and enable the factors to be targeted to improve the level of patient safety management.

  4. Preventing errors in administration of parenteral drugs: the results of a four-year national patient safety program.

    NARCIS (Netherlands)

    Blok, C. de; Schilp, J.; Wagner, C.

    2013-01-01

    Objectives: To evaluate the implementation of a four-year national patient safety program concerning the parenteral drug administration process in the Netherlands. Methods: Structuring the preparation and administration process of parenteral drugs reduces the number of medication errors. A

  5. Teamwork and Clinical Error Reporting among Nurses in Korean Hospitals

    Directory of Open Access Journals (Sweden)

    Jee-In Hwang, PhD

    2015-03-01

    Conclusions: Teamwork was rated as moderate and was positively associated with nurses' error reporting performance. Hospital executives and nurse managers should make substantial efforts to enhance teamwork, which will contribute to encouraging the reporting of errors and improving patient safety.

  6. Errors in fracture diagnoses in the emergency department--characteristics of patients and diurnal variation

    DEFF Research Database (Denmark)

    Hallas, Peter; Ellingsen, Trond

    2006-01-01

    Evaluation of the circumstances related to errors in diagnosis of fractures at an Emergency Department may suggest ways to reduce the incidence of such errors.......Evaluation of the circumstances related to errors in diagnosis of fractures at an Emergency Department may suggest ways to reduce the incidence of such errors....

  7. [Patient identification errors and biological samples in the analytical process: Is it possible to improve patient safety?].

    Science.gov (United States)

    Cuadrado-Cenzual, M A; García Briñón, M; de Gracia Hills, Y; González Estecha, M; Collado Yurrita, L; de Pedro Moro, J A; Fernández Pérez, C; Arroyo Fernández, M

    2015-01-01

    Patient identification errors and biological samples are one of the problems with the highest risk factor in causing an adverse event in the patient. To detect and analyse the causes of patient identification errors in analytical requests (PIEAR) from emergency departments, and to develop improvement strategies. A process and protocol was designed, to be followed by all professionals involved in the requesting and performing of laboratory tests. Evaluation and monitoring indicators of PIEAR were determined, before and after the implementation of these improvement measures (years 2010-2014). A total of 316 PIEAR were detected in a total of 483,254 emergency service requests during the study period, representing a mean of 6.80/10,000 requests. Patient identification failure was the most frequent in all the 6-monthly periods assessed, with a significant difference (Perrors. However, we must continue working with this strategy, promoting a culture of safety for all the professionals involved, and trying to achieve the goal that 100% of the analytical and samples are properly identified. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  8. Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position

    Energy Technology Data Exchange (ETDEWEB)

    Stoiber, Eva Maria, E-mail: eva.stoiber@med.uni-heidelberg.de [Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg (Germany); Department of Medical Physics, German Cancer Research Center, Heidelberg (Germany); Giske, Kristina [Department of Medical Physics, German Cancer Research Center, Heidelberg (Germany); Schubert, Kai; Sterzing, Florian; Habl, Gregor; Uhl, Matthias; Herfarth, Klaus [Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg (Germany); Bendl, Rolf [Department of Medical Physics, German Cancer Research Center, Heidelberg (Germany); Medical Informatics, Heilbronn University, Heilbronn (Germany); Debus, Juergen [Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg (Germany)

    2011-12-01

    Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived from a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.

  9. Management of mental health disorders in HIV-positive patients

    African Journals Online (AJOL)

    Mental Health Guidelines Committee, Southern African HIV Clinicians Society, ... triple diagnosis (HIV/mental disorder/substance use disorder), or mental .... fatigue or loss of energy .... between 20% and 60% of HIV-positive adults suffer from some form ... patients on complex regimens should be reviewed regularly with a.

  10. Effects of micronutrients on oxidative stress in HIV positive patients ...

    African Journals Online (AJOL)

    Micronutrient supplementation was therefore shown to reduce oxidative stress in HIV positive patients on HAART and could possibly be very helpful as an adjunct in the treatment of this disease. Key Words: Antiretroviral, micronutrients, malondialdehyde, ART naïve, reactive oxygen species, supplementation.

  11. Evaluation of liver function tests of HIV positive patients on ...

    African Journals Online (AJOL)

    Liver enzymes-alanine and aspartate aminotransferases and alkaline phosphatase (AST, ALT and ALP), bilirubin and serum proteins were determined using standard laboratory methods and these parameters were used to evaluate the liver function of human immunodeficiency virus (HIV)- positive patients receiving ...

  12. INTRACRANIAL MASS LESIONS IN HIV-POSITIVE PATIENTS ...

    African Journals Online (AJOL)

    'encephalitis of obscure origin', brain abscess and tuberculoma / mycobacterial ... Studies of IML in HN-positive patients emanate primarily from the ... Fig. 3. Mass on this CT scan found to be due to toxoplasmosis. Table H. Histological findings in the operated cases. Total biopsied/operated. 38'. Diagnosis. 0. Toxoplasmosis.

  13. Ovarian pregnancy in an HIV positive patient: Case report ...

    African Journals Online (AJOL)

    Ovarian pregnancy in an HIV positive patient: Case report. A Mohammed, AG Adesiyun, AA Mayun, CA Ameh. Abstract. No Abstract. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians ...

  14. A patient positioning system in head and neck irradiation

    International Nuclear Information System (INIS)

    Bormann, U.; Strauch, B.; Schmitt, G.

    1986-01-01

    A holding system is presented which allows a good, easy, and reproducable positioning of the patient in percutanous head and neck radiotherapy. The patients are lying comfortably on a neck support and are fixed in such a way that they are not able to turn in a lateral or longitudinal direction. The distance chin-jugulum can be easily determined by an integrated measuring tape. Due to the use of UV ink and UV lamps, the field marking of the patient's skin cannot be seen in the spectrum of visible light. (orig.) [de

  15. [Manegement and countermeasures against tuberculous patients with chronic positive sputum].

    Science.gov (United States)

    Sato, K

    1996-01-01

    We studied measures for the prevention and treatment of chronic positive-sputum tuberculosis. Most physicians treating chronic intractable pulmonary tuberculosis are concerned about treatment and control measures. However, both the medical and social aspects of the disease must be dealt with. The study of the medical aspects of tuberculosis used data on patients at the Tokyo National Chest Hospital and other sanitoria in Japan. The socioeconomic study employed data from a health center in Tokyo. Recently, new cases of tuberculosis are concentrated in socioeconomically high risk groups, such as the homeless and illegal aliens, in a few large cities. Patients in these groups often have multidrug-resistant tuberculosis (MDRTB), including many patients with relapsing tuberculosis. However, it is dificult to keep such patients under treatment because of poor compliance and patient dropout. The results of our study are summarized as follows: 1. Prevention and treatment of chronic intractable tuberculosis should involve both the medical and socioeconomic aspects of the disease. 2. Surgical treatment offers benefits for patients with chronically positive sputum. Therefore, surgery should be recommended to patients with chronic intractable MDRTB. 3. If resistance to both isoniazid and rifampin is demonstrated, it is better to replace all ineffective drugs with a new effective regimen than to add a single drug to a failing regimen.

  16. Is it possible to eliminate patient identification errors in medical imaging?

    Science.gov (United States)

    Danaher, Luke A; Howells, Joan; Holmes, Penny; Scally, Peter

    2011-08-01

    The aim of this article is to review a system that validates and documents the process of ensuring the correct patient, correct site and side, and correct procedure (commonly referred to as the 3 C's) within medical imaging. A 4-step patient identification and procedure matching process was developed using health care and aviation models. The process was established in medical imaging departments after a successful interventional radiology pilot program. The success of the project was evaluated using compliance audit data, incident reporting data before and after the implementation of the process, and a staff satisfaction survey. There was 95% to 100% verification of site and side and 100% verification of correct patient, procedure, and consent. Correct patient data and side markers were present in 82% to 95% of cases. The number of incidents before and after the implementation of the 3 C's was difficult to assess because of a change in reporting systems and incident underreporting. More incidents are being reported, particularly "near misses." All near misses were related to incorrect patient identification stickers being placed on request forms. The majority of staff members surveyed found the process easy (55.8%), quick (47.7%), relevant (51.7%), and useful (60.9%). Although identification error is difficult to eliminate, practical initiatives can engender significant systems improvement in complex health care environments. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  17. HDV Seroprevalence in HBsAg Positive Patients

    International Nuclear Information System (INIS)

    Abbasi, A.; Bhutto, A. R.; Mahmood, K.; Butt, N.

    2014-01-01

    Objective: To find out the frequency of HDV seroprevalence and the demographic characteristics or HBsAg-HDV positive patients. Study Design: Cross-sectional analytical study. Place and Duration of Study: Jinnah Postgraduate Medical Centre and Civil Hospital, Medical Unit-III, Karachi, from March 2007 to April 2011. Methodology: Patients with positive HBsAg were included in the study. Those having co-infection with HCV or HIV, autoimmune hepatitis, alcoholic hepatitis, Wilson's disease and haemochromatosis were excluded. After detailed history and physical examination all the patients underwent laboratory workup including complete blood count, liver function test, viral profile (HAV, HCV, HIV and anti-HDV) and prothrombin time. While in selected patients, HBc (core) antibodies, ultrasound abdomen, serum iron profile, ANA and liver biopsy were also carried out whenever needed to establish a clinical stage of liver disease. Results: There were 374 patients with 266 (71.1%) males and 108 (28.9%) females with overall mean age of 31.64 +- 8.66 years. Overall frequency of anti-HDV antibodies positivity was found in 28.1% (n = 105) patients. HDV seropositivity was slightly more prevalent in males as compared to females (28.57% vs. 26.57%). HDV seropositivity frequency was significantly higher in patients who presented with acute hepatitis/hepatic failure as compared to other clinical diagnoses (p = 0.027) and in those sub-sets of patients who had raised ALT levels (p = 0.012). Conclusion: There was a high frequency of HDV seropositivity in the studied population particularly in males with acute hepatitis or hepatic failure, having raised ALT levels. The emphasis should be on preventive measures taken by other countries to reduce the prevalence of these treatment challenging infections. (author)

  18. Breast cancer patients' narratives about positive and negative communication experiences

    DEFF Research Database (Denmark)

    Thomsen, Dorthe K; Pedersen, Anette F; Johansen, Mikael B

    2007-01-01

    . Thus, qualitative studies of communication are also needed. Fifteen breast cancer patients were interviewed 3 months after finishing adjuvant treatment. They were asked to tell a 10 minute narrative and recall five experiences from treatment. Themes were extracted using categories derived from previous...... research while at the same time being sensitive to new elaborations and categories. The participants reported both positive and negative communication-related experiences from a wide range of treatment situations. Two major themes emerged: Information giving as professional care-giving and meeting......Health staff-patient communication is increasingly considered an important issue in cancer research. However, questionnaires addressing satisfaction with communication limit the issues patients can raise, do not address the context of communication and often show a strong positive skew in responses...

  19. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    International Nuclear Information System (INIS)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y.; Hibbard, Roberta A.; Hicks, Ralph A.

    2017-01-01

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  20. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y. [Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Hibbard, Roberta A.; Hicks, Ralph A. [Indiana University School of Medicine, Department of Pediatrics, Section of Child Protection Programs, Indianapolis, IN (United States)

    2017-07-15

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  1. Decisions to Shoot in a Weapon Identification Task: The Influence of Cultural Stereotypes and Perceived Threat on False Positive Errors

    OpenAIRE

    Fleming, Kevin K.; Bandy, Carole L.; Kimble, Matthew O.

    2009-01-01

    The decision to shoot engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC) where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and EEG activ...

  2. Neurological manifestations in HIV positive patients in Tehran, Iran

    Directory of Open Access Journals (Sweden)

    Minoo Mohraz

    2014-02-01

    Full Text Available Objective: To evaluate the neurological complications among Iranian HIV-positive patients. Methods: This cross-sectional study was conducted among 428 patients diagnosed with HIV infection between 2006 and 2009 at Imam Khomeini hospital, Tehran, Iran. Demographic and clinical variables as well as laboratory tests were extracted and analyzed. Also, another 100 patients refereed to Voluntary Counseling and Testing center of the hospital were visited and evaluated for neurological complications. Results: Among the patients, neurologic manifestations were observed in 34 (7.94% patients. Twenty three percent of the patients received antiretroviral therapy. Identified causes included brain toxoplasmosis (14.7%, progressive multi-focal leuko encephalopathy (5.9%, HIV encephalopathy (5.9%, TB meningitis (5% and unknown etiologies (11.8%. Also, among 100 patients who were admitted and visited at the Voluntary Counseling and Testing center, no one was diagnosed for any neurological manifestations. Conclusions: According to our results, toxoplasmosis is the most frequent cause of neurological conditions among Iranian HIV infected patients and should be considered in any HIV/AIDS patient with neurological manifestations.

  3. Prevention of prescription errors by computerized, on-line, individual patient related surveillance of drug order entry.

    Science.gov (United States)

    Oliven, A; Zalman, D; Shilankov, Y; Yeshurun, D; Odeh, M

    2002-01-01

    Computerized prescription of drugs is expected to reduce the number of many preventable drug ordering errors. In the present study we evaluated the usefullness of a computerized drug order entry (CDOE) system in reducing prescription errors. A department of internal medicine using a comprehensive CDOE, which included also patient-related drug-laboratory, drug-disease and drug-allergy on-line surveillance was compared to a similar department in which drug orders were handwritten. CDOE reduced prescription errors to 25-35%. The causes of errors remained similar, and most errors, on both departments, were associated with abnormal renal function and electrolyte balance. Residual errors remaining on the CDOE-using department were due to handwriting on the typed order, failure to feed patients' diseases, and system failures. The use of CDOE was associated with a significant reduction in mean hospital stay and in the number of changes performed in the prescription. The findings of this study both quantity the impact of comprehensive CDOE on prescription errors and delineate the causes for remaining errors.

  4. TH-B-BRC-00: How to Identify and Resolve Potential Clinical Errors Before They Impact Patients Treatment: Lessons Learned

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

  5. TH-B-BRC-00: How to Identify and Resolve Potential Clinical Errors Before They Impact Patients Treatment: Lessons Learned

    International Nuclear Information System (INIS)

    2016-01-01

    Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803

  6. Dosimetric Changes Resulting From Patient Rotational Setup Errors in Proton Therapy Prostate Plans

    International Nuclear Information System (INIS)

    Sejpal, Samir V.; Amos, Richard A.; Bluett, Jaques B.; Levy, Lawrence B.; Kudchadker, Rajat J.; Johnson, Jennifer; Choi, Seungtaek; Lee, Andrew K.

    2009-01-01

    Purpose: To evaluate the dose changes to the target and critical structures from rotational setup errors in prostate cancer patients treated with proton therapy. Methods and Materials: A total of 70 plans were analyzed for 10 patients treated with parallel-opposed proton beams to a dose of 7,600 60 Co-cGy-equivalent (CcGE) in 200 CcGE fractions to the clinical target volume (i.e., prostate and proximal seminal vesicles). Rotational setup errors of +3 o , -3 deg., +5 deg., and -5 deg. (to simulate pelvic tilt) were generated by adjusting the gantry. Horizontal couch shifts of +3 deg. and -3 deg. (to simulate longitudinal setup variability) were also generated. Verification plans were recomputed, keeping the same treatment parameters as the control. Results: All changes shown are for 38 fractions. The mean clinical target volume dose was 7,780 CcGE. The mean change in the clinical target volume dose in the worse case scenario for all shifts was 2 CcGE (absolute range in worst case scenario, 7,729-7,848 CcGE). The mean changes in the critical organ dose in the worst case scenario was 6 CcGE (bladder), 18 CcGE (rectum), 36 CcGE (anterior rectal wall), and 141 CcGE (femoral heads) for all plans. In general, the percentage of change in the worse case scenario for all shifts to the critical structures was <5%. Deviations in the absolute percentage of volume of organ receiving 45 and 70 Gy for the bladder and rectum were <2% for all plans. Conclusion: Patient rotational movements of 3 deg. and 5 deg. and horizontal couch shifts of 3 deg. in prostate proton planning did not confer clinically significant dose changes to the target volumes or critical structures.

  7. Relationship Between Patients' Perceptions of Care Quality and Health Care Errors in 11 Countries: A Secondary Data Analysis.

    Science.gov (United States)

    Hincapie, Ana L; Slack, Marion; Malone, Daniel C; MacKinnon, Neil J; Warholak, Terri L

    2016-01-01

    Patients may be the most reliable reporters of some aspects of the health care process; their perspectives should be considered when pursuing changes to improve patient safety. The authors evaluated the association between patients' perceived health care quality and self-reported medical, medication, and laboratory errors in a multinational sample. The analysis was conducted using the 2010 Commonwealth Fund International Health Policy Survey, a multinational consumer survey conducted in 11 countries. Quality of care was measured by a multifaceted construct developed using Rasch techniques. After adjusting for potentially important confounding variables, an increase in respondents' perceptions of care coordination decreased the odds of self-reporting medical errors, medication errors, and laboratory errors (P < .001). As health care stakeholders continue to search for initiatives that improve care experiences and outcomes, this study's results emphasize the importance of guaranteeing integrated care.

  8. Exploring Positive Survivorship Experiences of Indigenous Australian Cancer Patients

    Science.gov (United States)

    Tam, Laura; Garvey, Gail; Meiklejohn, Judith; Martin, Jennifer; Adams, Jon; Walpole, Euan; Fay, Michael; Valery, Patricia

    2018-01-01

    Amongst Indigenous Australians, “cancer” has negative connotations that detrimentally impact upon access to cancer care services. Barriers to accessing cancer services amongst Indigenous Australians are widely reported. In contrast, factors that facilitate this cohort to successfully navigate cancer care services (“enablers”) are scarcely reported in the literature. Through qualitative interviews, this article examines factors that assist Indigenous Australians to have positive cancer experiences. Semi-structured interviews were conducted with twelve adult Indigenous oncology patients recruited from a tertiary hospital in Queensland, Australia during 2012–2014. Data generated from the interviews were independently reviewed by two researchers via inductive thematic analytical processes. Discussions followed by consensus on the major categories allowed conclusions to be drawn on potential enablers. Two major categories of enablers were identified by the researchers: resilience and communication. Individual’s intrinsic strength, their coping strategies, and receipt of support improved participant’s resilience and consequently supported a positive experience. Communication methods and an effective patient-provider relationship facilitated positive experiences for participants. Despite potential barriers to access of care for Indigenous cancer patients, participants in the study demonstrated that it was still possible to focus on the positive aspects of their cancer experiences. Many participants explained how cancer changed their outlook on life, often for the better, with many feeling empowered as they progressed through their cancer diagnosis and treatment processes. PMID:29342934

  9. Epidemiology of Adverse Events and Medical Errors in the Care of Cardiology Patients.

    Science.gov (United States)

    Ohta, Yoshinori; Miki, Izumi; Kimura, Takeshi; Abe, Mitsuru; Sakuma, Mio; Koike, Kaoru; Morimoto, Takeshi

    2016-11-02

    There have been epidemiological studies of adverse events (AEs) among general patients but those of patients cared by cardiologist are not well scrutinized. We investigated the occurrence of AEs and medical errors (MEs) among adult patients with cardiology in Japan. We conducted a cross-sectional study of adult outpatients at a Japanese teaching hospital from February through November 2006. We measured AE and ME incidents from patient report, which were verified by medical records, laboratory data, incident reports, and prescription queries. Two independent physicians reviewed the incidents to determine whether they were AEs or MEs and to assess severity and symptoms. We identified 144 AEs and 30 MEs (16.3 and 3.9 per 100 patients, respectively). Of the 144 AEs, 99 were solely adverse drug events (ADEs), 20 were solely non-ADEs, and the remaining 25 were both causes. The most frequent symptoms of ADEs were skin and allergic reactions due to medication. The most frequent symptoms of non-ADEs were bleeding due to therapeutic interventions. Among AEs, 12% was life threatening. Life-threatening AEs were 25% of non-ADEs and 5% of ADEs (P = 0.0003). Among the 30 MEs, 21MEs (70%) were associated with drugs. Adverse events were common among cardiology patients. Adverse drug events were the most frequent AEs, and non-ADEs were more critical than ADEs. Such data should be recognized among practicing physicians to improve the patients' outcomes.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially.

  10. Medication errors versus time of admission in a subpopulation of stroke patients undergoing inpatient rehabilitation complications and considerations.

    Science.gov (United States)

    Pitts, Eric P

    2011-01-01

    This study looked at the medication ordering error frequency and the length of inpatient hospital stay in a subpopulation of stroke patients (n-60) as a function of time of patient admission to an inpatient rehabilitation hospital service. A total of 60 inpatient rehabilitation patients, 30 arriving before 4 pm, and 30 arriving after 4 pm, with as admitting diagnosis of stroke were randomly selected from a larger sample (N=426). There was a statistically significant increase in medication ordering errors and the number of inpatient rehabilitation hospital days in the group of patients who arrived after 4 pm.

  11. A Case of Transfusion Error in a Trauma Patient With Subsequent Root Cause Analysis Leading to Institutional Change

    Directory of Open Access Journals (Sweden)

    Sean Patrick Clifford MD

    2016-05-01

    Full Text Available A 28-year-old man presented emergently to the operating room following a gun-shot injury to his right groin. Our hospital’s Massive Transfusion Protocol was initiated as the patient entered the operating room actively hemorrhaging and severely hypotensive. During the aggressive resuscitation efforts, the patient was inadvertently transfused 2 units of packed red blood cells intended for another patient due to a series of errors. Fortunately, the incorrect product was compatible, and the patient recovered from his near-fatal injuries. Root cause analysis was used to review the transfusion error and develop an action plan to help prevent future occurrences.

  12. A Case of Transfusion Error in a Trauma Patient With Subsequent Root Cause Analysis Leading to Institutional Change.

    Science.gov (United States)

    Clifford, Sean Patrick; Mick, Paul Brian; Derhake, Brian Matthew

    2016-01-01

    A 28-year-old man presented emergently to the operating room following a gun-shot injury to his right groin. Our hospital's Massive Transfusion Protocol was initiated as the patient entered the operating room actively hemorrhaging and severely hypotensive. During the aggressive resuscitation efforts, the patient was inadvertently transfused 2 units of packed red blood cells intended for another patient due to a series of errors. Fortunately, the incorrect product was compatible, and the patient recovered from his near-fatal injuries. Root cause analysis was used to review the transfusion error and develop an action plan to help prevent future occurrences.

  13. Stochastic formulation of patient positioning using linac-mounted cone beam imaging with prior knowledge

    International Nuclear Information System (INIS)

    Hoegele, W.; Loeschel, R.; Dobler, B.; Hesser, J.; Koelbl, O.; Zygmanski, P.

    2011-01-01

    Purpose: In this work, a novel stochastic framework for patient positioning based on linac-mounted CB projections is introduced. Based on this formulation, the most probable shifts and rotations of the patient are estimated, incorporating interfractional deformations of patient anatomy and other uncertainties associated with patient setup. Methods: The target position is assumed to be defined by and is stochastically determined from positions of various features such as anatomical landmarks or markers in CB projections, i.e., radiographs acquired with a CB-CT system. The patient positioning problem of finding the target location from CB projections is posed as an inverse problem with prior knowledge and is solved using a Bayesian maximum a posteriori (MAP) approach. The prior knowledge is three-fold and includes the accuracy of an initial patient setup (such as in-room laser and skin marks), the plasticity of the body (relative shifts between target and features), and the feature detection error in CB projections (which may vary depending on specific detection algorithm and feature type). For this purpose, MAP estimators are derived and a procedure of using them in clinical practice is outlined. Furthermore, a rule of thumb is theoretically derived, relating basic parameters of the prior knowledge (initial setup accuracy, plasticity of the body, and number of features) and the parameters of CB data acquisition (number of projections and accuracy of feature detection) to the expected estimation accuracy. Results: MAP estimation can be applied to arbitrary features and detection algorithms. However, to experimentally demonstrate its applicability and to perform the validation of the algorithm, a water-equivalent, deformable phantom with features represented by six 1 mm chrome balls were utilized. These features were detected in the cone beam projections (XVI, Elekta Synergy) by a local threshold method for demonstration purposes only. The accuracy of estimation

  14. Patient safety in dentistry - state of play as revealed by a national database of errors.

    Science.gov (United States)

    Thusu, S; Panesar, S; Bedi, R

    2012-08-01

    Modern dentistry has become increasingly invasive and sophisticated. Consequently the risk to the patient has increased. The aim of this study is to investigate the types of patient safety incidents (PSIs) that occur in dentistry and the accuracy of the National Patient Safety Agency (NPSA) database in identifying those attributed to dentistry. The database was analysed for all incidents of iatrogenic harm in the speciality of dentistry. A snapshot view using the timeframe January to December 2009 was used. The free text elements from the database were analysed thematically and reclassified according to the nature of the PSI. Descriptive statistics were provided. Two thousand and twelve incident reports were analysed and organised into ten categories. The commonest was due to clerical errors - 36%. Five areas of PSI were further analysed: injury (10%), medical emergency (6%), inhalation/ingestion (4%), adverse reaction (4%) and wrong site extraction (2%). There is generally low reporting of PSIs within the dental specialities. This may be attributed to the voluntary nature of reporting and the reluctance of dental practitioners to disclose incidences for fear of loss of earnings. A significant amount of iatrogenic harm occurs not during treatment but through controllable pre- and post-procedural checks. Incidences of iatrogenic harm to dental patients do occur but their reporting is not widely used. The use of a dental specific reporting system would aid in minimising iatrogenic harm and adhere to the Care Quality Commission (CQC) compliance monitoring system on essential standards of quality and safety in dental practices.

  15. Set-up errors in patients undergoing image guided radiation treatment. Relationship to body mass index and weight loss

    DEFF Research Database (Denmark)

    Johansen, Jørgen; Bertelsen, Anders; Hansen, Christian Rønn

    2008-01-01

    by the relative weight change over time. Results: The SD of the translational and rotational random set-up errors during the first three sessions for H&N were 0.9 mm (Left-Right), 1.1mm (Anterior-Posterior), 0.7 mm (Cranio-Caudal) and 0.7 degrees (LR-axis), 0.5 degrees (AP-axis), and 0.7 degrees (CC......-axis). The equivalent data for lung cancer patients were 1.1 mm (LR), 1.1mm (AP), 1.5 mm (CC) and 0.5 degrees (LR-axis), 0.6 degrees (AP-axis), and 0.4 degrees (CC-axis). The median BMI for H&N and lung was 25.8 (17.6-39.7) and 23.7 (17.4-38.8), respectively. The median weekly weight change for H&N was -0.3% (-2.0 to 1...... (H&N) and 20 lung cancer patients were investigated. Patients were positioned using customized immobilization devices consisting of vacuum cushions and thermoplastic shells. Treatment was given on an Elekta Synergy accelerator. Cone-beam acquisitions were obtained according to a standardized Action...

  16. Lumbar Lordosis of Spinal Stenosis Patients during Intraoperative Prone Positioning

    Science.gov (United States)

    Lee, Su-Keon; Song, Kyung-Sub; Park, Byung-Moon; Lim, Sang-Youn; Jang, Geun; Lee, Beom-Seok; Moon, Seong-Hwan; Lee, Hwan-Mo

    2016-01-01

    Background To evaluate the effect of spondylolisthesis on lumbar lordosis on the OSI (Jackson; Orthopaedic Systems Inc.) frame. Restoration of lumbar lordosis is important for maintaining sagittal balance. Physiologic lumbar lordosis has to be gained by intraoperative prone positioning with a hip extension and posterior instrumentation technique. There are some debates about changing lumbar lordosis on the OSI frame after an intraoperative prone position. We evaluated the effect of spondylolisthesis on lumbar lordosis after an intraoperative prone position. Methods Sixty-seven patients, who underwent spinal fusion at the Department of Orthopaedic Surgery of Gwangmyeong Sungae Hospital between May 2007 and February 2012, were included in this study. The study compared lumbar lordosis on preoperative upright, intraoperative prone and postoperative upright lateral X-rays between the simple stenosis (SS) group and spondylolisthesis group. The average age of patients was 67.86 years old. The average preoperative lordosis was 43.5° (± 14.9°), average intraoperative lordosis was 48.8° (± 13.2°), average postoperative lordosis was 46.5° (± 16.1°) and the average change on the frame was 5.3° (± 10.6°). Results Among all patients, 24 patients were diagnosed with simple spinal stenosis, 43 patients with spondylolisthesis (29 degenerative spondylolisthesis and 14 isthmic spondylolisthesis). Between the SS group and spondylolisthesis group, preoperative lordosis, intraoperative lordosis and postoperative lordosis were significantly larger in the spondylolisthesis group. The ratio of patients with increased lordosis on the OSI frame compared to preoperative lordosis was significantly higher in the spondylolisthesis group. The risk of increased lordosis on frame was significantly higher in the spondylolisthesis group (odds ratio, 3.325; 95% confidence interval, 1.101 to 10.039; p = 0.033). Conclusions Intraoperative lumbar lordosis on the OSI frame with a prone

  17. Breast Gangrene in an HIV-Positive Patient

    Science.gov (United States)

    Venkatramani, V; Pillai, S; Marathe, S; Rege, SA; Hardikar, JV

    2009-01-01

    Introduction Breast gangrene has been reported as a complication following puerperal sepsis, breast surgery, nipple piercings, warfarin toxicity, etc. We report a case of primary breast gangrene in an HIV-positive individual which, to the best of our knowledge, is the first of its kind. Case report A 40-year-old previously healthy woman presented with fulminating left breast gangrene. She was detected to be HIV positive. Mastectomy was performed. The detailed management of the condition is discussed. Conclusion Severe necrotising infections may be initial manifestations of HIV infection and patients with such infections should be screened for HIV. PMID:19622255

  18. Vertigo in patients with benign paroxysmal positional vertigo.

    Science.gov (United States)

    Kentala, E; Pyykkö, I

    2000-01-01

    We retrieved information on 59 patients, 19 men and 40 women, with benign paroxysmal positional vertigo (BPPV) from the database of the otoneurologic expert system (ONE). The original number of patients was greater, but we excluded all those with hearing loss of any origin. The patients filled in a questionnaire concerning their symptoms, earlier diseases, accidents and tobacco and alcohol use. This information was then integrated with results of audiometric, otoneurologic and imaging studies. The mean age at onset of symptoms was 44 years. Most patients had had vertiginous spells for anxiety than the others [r(53) = 0.40, p floating sensation. The floating vertigo was most often provoked by pressure changes [r(54) = 0.41, p < 0.01] or changes in visual surroundings [r(54) = 0.52, p < 0.01].

  19. Our trial to improve patient positioning during mammography

    International Nuclear Information System (INIS)

    Nakayama, Takashi; Kotsuma, Yoshikazu; Hiramatsu, Sawako

    2007-01-01

    For effective breast cancer screening, reading of high-quality mammograms is essential, and for this purpose proper patient positioning during mammography is important. At our Shin-Osaka Mammography Seminar, which includes eight institutions, a physician and nine radiology technicians get together weekly in order to critically review mammogram reading and techniques for obtaining good mammograms. We have recognized that patient positioning has a great effect on mammogram quality, particularly for women in their 40 s who have dense mammary glands, and we have adopted a digital mammography system, or comparative mammography for such patients. Since July 2005, we have critically reviewed positioning every 3 or 4 months with the aim of improving our technique. Eight institutions have participated in this trial, each contributing mammograms taken recently from 20 to 30 consecutive participants, and the grade of positioning has been determined according to the Institutional Mammogram Estimation Standard (6 items, each scoring a maximum of 4 points, total 24 points) proposed by the Central Committee for Quality Control of Mammography Screening. The estimation has been done by both ourselves and committee members. When a total of 20 points or more is obtained and all 6 items score 3 points or more, it is considered that the positioning has been good, and this is termed ''Positioning A'' (P-A). On the other hand, if the total score is less than 20 points, and any one of the 6 items scores less than 3 points, it is considered that positioning has been inadequate, and this is termed ''Positioning-D'' (P-D). At the first review meeting, which was held before our critical study, P-A accounted for 48% of cases, and this had improved to 72% at the second meeting, and to 66% at the third. P-D accounted for 41% of cases at the first meeting, 20% at the second, and 21% at the third. Thus our trial involving discussion between a physician and technicians to critically review good

  20. System care improves trauma outcome: patient care errors dominate reduced preventable death rate.

    Science.gov (United States)

    Thoburn, E; Norris, P; Flores, R; Goode, S; Rodriguez, E; Adams, V; Campbell, S; Albrink, M; Rosemurgy, A

    1993-01-01

    A review of 452 trauma deaths in Hillsborough County, Florida, in 1984 documented that 23% of non-CNS trauma deaths were preventable and occurred because of inadequate resuscitation or delay in proper surgical care. In late 1988 Hillsborough County organized a County Trauma Agency (HCTA) to coordinate trauma care among prehospital providers and state-designated trauma centers. The purpose of this study was to review county trauma deaths after the inception of the HCTA to determine the frequency of preventable deaths. 504 trauma deaths occurring between October 1989 and April 1991 were reviewed. Through committee review, 10 deaths were deemed preventable; 2 occurred outside the trauma system. Of the 10 deaths, 5 preventable deaths occurred late in severely injured patients. The preventable death rate has decreased to 7.0% with system care. The causes of preventable deaths have changed from delayed or inadequate intervention to postoperative care errors.

  1. Chiropractic management of a patient with benign paroxysmal positional vertigo

    DEFF Research Database (Denmark)

    Nørregaard, Anette R; Lauridsen, Henrik H; Hartvigsen, Jan

    2009-01-01

    OBJECTIVE: This article describes and discusses the case of a patient with benign paroxysmal positional vertigo (BPPV) characterized by severe vertigo with dizziness, nausea, and nystagmus, treated without the use of spinal manipulation by a doctor of chiropractic. CLINICAL FEATURES: A 46-year......-old woman presented for care with complaints of acute vertigo and dizziness. INTERVENTION AND OUTCOME: The patient was examined and diagnosed with left posterior canalolithiasis by means of the Dix-Hallpike maneuver. She was treated successfully with the Epley maneuver once and subsequently discharged...

  2. Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study.

    Science.gov (United States)

    Walch, Gilles; Vezeridis, Peter S; Boileau, Pascal; Deransart, Pierric; Chaoui, Jean

    2015-02-01

    Glenoid component positioning is a key factor for success in total shoulder arthroplasty. Three-dimensional (3D) measurements of glenoid retroversion, inclination, and humeral head subluxation are helpful tools for preoperative planning. The purpose of this study was to assess the reliability and precision of a novel surgical method for placing the glenoid component with use of patient-specific templates created by preoperative surgical planning and 3D modeling. A preoperative computed tomography examination of cadaveric scapulae (N = 18) was performed. The glenoid implants were virtually placed, and patient-specific guides were created to direct the guide pin into the desired orientation and position in the glenoid. The 3D orientation and position of the guide pin were evaluated by performing a postoperative computed tomography scan for each scapula. The differences between the preoperative planning and the achieved result were analyzed. The mean error in 3D orientation of the guide pin was 2.39°, the mean entry point position error was 1.05 mm, and the mean inclination angle error was 1.42°. The average error in the version angle was 1.64°. There were no technical difficulties or complications related to use of patient-specific guides for guide pin placement. Quantitative analysis of guide pin positioning demonstrated a good correlation between preoperative planning and the achieved position of the guide pin. This study demonstrates the reliability and precision of preoperative planning software and patient-specific guides for glenoid component placement in total shoulder arthroplasty. Copyright © 2015. Published by Elsevier Inc.

  3. When doctors share visit notes with patients: a study of patient and doctor perceptions of documentation errors, safety opportunities and the patient-doctor relationship.

    Science.gov (United States)

    Bell, Sigall K; Mejilla, Roanne; Anselmo, Melissa; Darer, Jonathan D; Elmore, Joann G; Leveille, Suzanne; Ngo, Long; Ralston, James D; Delbanco, Tom; Walker, Jan

    2017-04-01

    Patient advocates and safety experts encourage adoption of transparent health records, but sceptics worry that shared notes may offend patients, erode trust or promote defensive medicine. As electronic health records disseminate, such disparate views fuel policy debates about risks and benefits of sharing visit notes with patients through portals. Presurveys and postsurveys from 99 volunteer doctors at three US sites who participated in OpenNotes and postsurveys from 4592 patients who read at least one note and submitted a survey. Patients read notes to be better informed and because they were curious; about a third read them to check accuracy. In total, 7% (331) of patients reported contacting their doctor's office about their note. Of these, 29% perceived an error, and 85% were satisfied with its resolution. Nearly all patients reported feeling better (37%) or the same (62%) about their doctor. Patients who were older (>63), male, non-white, had fair/poor self-reported health or had less formal education were more likely to report feeling better about their doctor. Among doctors, 26% anticipated documentation errors, and 44% thought patients would disagree with notes. After a year, 53% believed patient satisfaction increased, and 51% thought patients trusted them more. None reported ordering more tests or referrals. Despite concerns about errors, offending language or defensive practice, transparent notes overall did not harm the patient-doctor relationship. Rather, doctors and patients perceived relational benefits. Traditionally more vulnerable populations-non-white, those with poorer self-reported health and those with fewer years of formal education-may be particularly likely to feel better about their doctor after reading their notes. Further informing debate about OpenNotes, the findings suggest transparent records may improve patient satisfaction, trust and safety. Published by the BMJ Publishing Group Limited. For permission to use (where not already

  4. Osseous Kaposi sarcoma in an HIV-positive patient

    International Nuclear Information System (INIS)

    Thanos, Loukas; Mylona, Sofia; Kalioras, Vasilios; Pomoni, Maria; Batakis, Nikolaos

    2004-01-01

    A case of osseous Kaposi sarcoma in a 35-year-old man is described. The patient (HIV-positive for 8 years) suffered from cutaneous Kaposi sarcoma and presented with right-sided chest pain. He underwent a chest CT scan that revealed three osteolytic lesions involving rib and vertebra with large soft tissue masses, without cutaneous lesions at these sites. CT-guided core needle biopsy led to a histological diagnosis of Kaposi sarcoma. (orig.)

  5. When Patients Divorce: The Family Physician's Legal Position

    OpenAIRE

    Mesbur, Ruth E.

    1983-01-01

    When divorce and family disintegration loom, the family physician is often the first outsider on the scene. The family physician may, indeed, have a critical role to play in handling the crisis; he may advise, refer to other professionals like therapists or lawyers, or appear in court as an expert witness. The physician must consider his legal position. Is reconciliation counselling confidential, privileged information? Can he recommend a lawyer for a patient? What is the physician's vulnerab...

  6. [Measures to prevent patient identification errors in blood collection/physiological function testing utilizing a laboratory information system].

    Science.gov (United States)

    Shimazu, Chisato; Hoshino, Satoshi; Furukawa, Taiji

    2013-08-01

    We constructed an integrated personal identification workflow chart using both bar code reading and an all in-one laboratory information system. The information system not only handles test data but also the information needed for patient guidance in the laboratory department. The reception terminals at the entrance, displays for patient guidance and patient identification tools at blood-sampling booths are all controlled by the information system. The number of patient identification errors was greatly reduced by the system. However, identification errors have not been abolished in the ultrasound department. After re-evaluation of the patient identification process in this department, we recognized that the major reason for the errors came from excessive identification workflow. Ordinarily, an ultrasound test requires patient identification 3 times, because 3 different systems are required during the entire test process, i.e. ultrasound modality system, laboratory information system and a system for producing reports. We are trying to connect the 3 different systems to develop a one-time identification workflow, but it is not a simple task and has not been completed yet. Utilization of the laboratory information system is effective, but is not yet perfect for patient identification. The most fundamental procedure for patient identification is to ask a person's name even today. Everyday checks in the ordinary workflow and everyone's participation in safety-management activity are important for the prevention of patient identification errors.

  7. Patient positioning and its influence on dose distribution

    International Nuclear Information System (INIS)

    Morrissey, J.; Moss, R.; Watkins, P.

    2000-01-01

    In comparison to conventional radiotherapy, the positioning of a patient for BNCT treatment has some unique aspects. In particular, the neutron beam coming from the core of a nuclear research reactor is fixed and horizontal. In particular, a head fixation mask, which is prepared at the patient referral hospital, is included in the CT images. The mask allows reproducible positioning for use during the treatment. Fiducial markers placed on the mask before imaging, provide reference points. The INEEL treatment planning code used in Petten produces a beam angle, and beam line entrance and exit co-ordinates. These are related to the fiducial marker co-ordinates. A spreadsheet, named COSINE, developed at Petten produces positioning co-ordinates from the data produced by the rtt MC code. These co-ordinates are related to a positioning frame, which allows the marking of the beams on the mask. In order to have reliable treatment data, the influence of small deviations of angle or target point on dose distribution must be known. To demonstrate this, a number of beams have been calculated with the Petten beam, with slight variations and compared with an approved plan. (author)

  8. HIV positive patient with GBS-like syndrome.

    Science.gov (United States)

    Shepherd, Samantha J; Black, Heather; Thomson, Emma C; Gunson, Rory N

    2017-08-01

    Introduction. Guillain-Barré Syndrome (GBS) is an acute demyelinating polyneuropathy which can occur post-infection. Criteria of diagnosis of GBS include areflexia with progressive bilateral weakness in arms and legs. GBS can lead to severe respiratory and cardiac complications. The fatality rate can be up to 5 % in patients, depending on the severity of the symptoms. HIV can cause a range of neurological disorders including, on rare occasions, GBS. GBS can occur at any stage of HIV infection, highlighting the complexity of diagnosis of GBS within HIV patients. Case presentation. A 57 year old female with lumbar back pain radiating to the legs, poor mobility and tiredness, with reports of a viral-like illness four days previously, was initially diagnosed with a lower respiratory tract infection and discharged. Seventeen days later the patient was readmitted to hospital with progressive lower and upper limb weakness, areflexia and sensory loss. She was diagnosed with GBS and was unexpectedly discovered to be HIV-positive. HIV avidity was low indicating a recently acquired HIV infection. The patient was treated with intravenous immunoglobulin for five days for the GBS and commenced antriretrovirals for HIV. The patient was discharge from hospital 53 days after admission with walking aids and regular physiotherapy follow-up. . This case highlighted the need for all clinicians to be aware that patients with symptoms of GBS, regardless of clinical history should be offered an HIV test. GBS can be the first sign a patient is HIV-positive.

  9. Effect of patient position on the lordosis and scoliosis of patients with degenerative lumbar scoliosis.

    Science.gov (United States)

    Fei, Han; Li, Wei-Shi; Sun, Zhuo-Ran; Jiang, Shuai; Chen, Zhong-Qiang

    2017-08-01

    This study aimed to analyze the effect of patient positions on the lordosis and scoliosis of patients with degenerative lumbar scoliosis (DLS).Seventy-seven patients with DLS were retrospectively analyzed. We measured lordosis and Cobb's angle on preoperative upright x-rays and magnetic resonance imagings in supine position. The lordosis and scoliosis of surgical segments in intraoperative prone position were measured on intraoperative radiographs of 20 patients to compare with that in standing position. Paired t tests were performed to investigate the parameters of the sample.From standing to supine position the whole lordosis increased (29.2 ± 15.7 degree vs. 34.9 ± 11.2 degree), and the whole scoliosis decreased (24.3 ± 11.8 degree vs. 19.0 ± 10.5 degree); 53 of 77 (68.8%) cases had increased lordosis, and 67 of 77 (87%) cases had decreased scoliosis. The lordosis of surgical segments in standing position had no difference with that in intraoprerative prone position. But in changing from supine/standing position to intraoprerative prone position, the scoliosis of surgical segments decreased (14.7 ± 9.4 degree vs. 11.4 ± 7.0 degree; 19.0 ± 11.8 degree vs. 11.4 ± 7.0 degree, respectively), and 18 of 20 (90%) cases had decreased scoliosis in intraoperative prone position than that in standing position.Compared with standing position in DLS patients, supine position increased lordosis and reduced scoliosis, and intraoperative prone position reduced scoliosis significantly. When evaluating the severity of DLS and making preoperative surgical plans, lumbar lordosis in supine position should also be evaluated in addition to upright x-ray, and the effects of different positions should be taken into consideration to reduce deviation.

  10. Tuberculous iliopsoas abscess in a HIV positive female patient

    International Nuclear Information System (INIS)

    Elenkov, I.; Tomov, T.; Stefanov, P.; Genov, P.; Dineva, S.; Alexiev, I.; Nikolova, M.

    2015-01-01

    Patients with HIV can often present a diagnostic challenge and may have atypical presentations of more common diseases. This case demonstrates a HIV (+) patient with an advanced immunosuppression with tuberculosis complaining about 2 months before admission to the hospital of backache, anorexia and weight loss. On investigation she was found to have unilateral tuberculous psoas abscesses, diagnosed microbiologically and with a CT scan. Complex treatment (surgical, tuberculostatics, antiretroviral) was performed with a good effect. A review of the literature shows that this is a rare presentation of an already unusual problem, with subtle signs requiring a high index of clinical suspicion. However, with HIV-positive patients more likely to present with extrapulmonary tuberculosis, there is need for increased awareness of this diagnosis. (authors) Key words: HIV. TUBERCULOUS PSOAS ABSCESS

  11. Positional shifting of HRCT findings in patients with pulmonary edema

    International Nuclear Information System (INIS)

    Kim, Young Sun; Choi, Yo Won; Jeon, Seok Chol; Park, Choong Ki; Seo, Heung Suk; Lee, Seung Rho; Hahm, Chang Kok

    2001-01-01

    To assess the value of positional shifting to a gravity-dependent area, as revealed by HRCT, in differentiating pulmonary edema (PE) from other conditions. Sixteen consecutive patients in whom plain radiographs suggested the presence of pulmonary edema but the clinical findings were indefinite underwent HRCT of the lung. For initial scanning they were in the supine position, and then in the prone position. Findings of ground-glass opacity, interlobular septal thickening and peribronchovascular interistitial thickening were analyzed in terms of the presence and degree of shifting to a gravity-dependent area, a grade of high, intermediate or low being assigned. PE was diagnosed in 8 of 16 cases, the remainder being designated as non-pulmonary edema (NPE). Ground-glass opacity was observed in all 16, while the degree of positional shifting was found to be high in ten (PE:NPE=6:4), intermediate in four (PE:NPE=2:2), and low in two (PE:NPE=0:2). There was no significant difference between the two groups (ρ > 0.05). Interlobular septal thickening was observed in all but two NPE cases; the degree of shifting was high in six (PE:NPE=6:0), intermediate in one (PE), and low in seven (PE:NPE=1:6). Shifting was significantly more prominent in PE than in NPE case (ρ <0.05). Peribronchovascular interstitial thickening was positive in all PE cases and one NPE case, with no positional shifting. Positional shifting of interlobular septal thickening to a gravity-dependent area, as demonstrated by HRCT, is the most specific indicator of pulmonary edema

  12. [Patient safety culture based on a non-punitive response to error and freedom of expression of healthcare professionals].

    Science.gov (United States)

    Mahjoub, Mohamed; Bouafia, Nabiha; Cheikh, Asma Ben; Ezzi, Olfa; Njah, Mansour

    2016-11-25

    This study provided an overview of healthcare professionals’ perception of patient safety based on analysis of the concept of freedom of expression and non-punitive response in order to identify and correct errors in our health system. This concept is a cornerstone of the patient safety culture among healthcare professionals and plays a central role in the quality improvement strategy..

  13. Metabolic syndrome in human immunodeficiency virus positive patients

    Directory of Open Access Journals (Sweden)

    Sarita Bajaj

    2013-01-01

    Full Text Available Aims and Objectives : To assess the prevalence of metabolic syndrome (MetS in human immunodeficiency virus (HIV positive patients. Prevalence of MetS was compared in patients who were not on highly active antiretroviral therapy (HAART to patients who were on HAART. Materials and Methods: Seventy HIV positive cases were studied. Pregnant and lactating women, patients on drugs other than HAART known to cause metabolic abnormalities and those having diabetes or hypertension were excluded. Cases were evaluated for MetS by using National Cholesterol Education Program Adult Treatment Panel-III. Results: 47 cases were on HAART and 23 cases were not on HAART. Fasting Blood Glucose ≥100 mg/dl was present in 28.6% cases, out of whom 27.7% were on HAART and 30.4% were not on HAART (P = 0.8089. 12.9% cases had BP ≥130/≥85 mm Hg, out of whom 14.9% were on HAART and 8.7% were not on HAART (P = 0.4666. 42.9% cases had TG ≥150 mg/dl, out of whom 44.7% were on HAART and 39.1% were not on HAART (P = 0.6894. HDL cholesterol was low (males <40 mg/dl, females <50 mg/dl in 50% cases, out of whom 55.3% were on HAART and 39.1% were not on HAART (P = 0.2035. Conclusions: Prevalence of MetS was 20%. Majority of patients had only one component of MetS (32.9%. Low HDL was present in 50%, followed by raised triglycerides in 42.9%. Waist circumference was not increased in any of the patients. There was no statistically significant difference between those on HAART and those not on HAART in distribution of risk factors and individual components of MetS.

  14. Measurement Errors Arising When Using Distances in Microeconometric Modelling and the Individuals’ Position Is Geo-Masked for Confidentiality

    Directory of Open Access Journals (Sweden)

    Giuseppe Arbia

    2015-10-01

    Full Text Available In many microeconometric models we use distances. For instance, in modelling the individual behavior in labor economics or in health studies, the distance from a relevant point of interest (such as a hospital or a workplace is often used as a predictor in a regression framework. However, in order to preserve confidentiality, spatial micro-data are often geo-masked, thus reducing their quality and dramatically distorting the inferential conclusions. In particular in this case, a measurement error is introduced in the independent variable which negatively affects the properties of the estimators. This paper studies these negative effects, discusses their consequences, and suggests possible interpretations and directions to data producers, end users, and practitioners.

  15. Route learning in amnesia: a comparison of trial-and-error and errorless learning in patients with the Korsakoff syndrome.

    Science.gov (United States)

    Kessels, Roy P C; van Loon, Eke; Wester, Arie J

    2007-10-01

    To examine the errorless learning approach using a procedural memory task (i.e. learning of actual routes) in patients with amnesia, as compared to trial-and-error learning. Counterbalanced self-controlled cases series. Psychiatric hospital (Korsakoff clinic). A convenience sample of 10 patients with the Korsakoff amnestic syndrome. All patients learned a route in four sessions on separate days using an errorless approach and a different route using trial-and-error. Error rate was scored during route learning and standard neuro-psychological tests were administered (i.e. subtest route recall of the Rivermead Behavioural Memory Test (RBMT) and the Dutch version of the California Verbal Learning Test (VLGT)). A significant learning effect was found in the trial-and-error condition over consecutive sessions (P = 0.006), but no performance difference was found between errorless and trial-and-error learning of the routes. VLGT performance was significantly correlated with a trial-and-error advantage (P Korsakoff syndrome (severe amnesia).

  16. [Medication reconciliation errors according to patient risk and type of physician prescriber identified by prescribing tool used].

    Science.gov (United States)

    Bilbao Gómez-Martino, Cristina; Nieto Sánchez, Ángel; Fernández Pérez, Cristina; Borrego Hernando, Mª Isabel; Martín-Sánchez, Francisco Javier

    2017-01-01

    To study the frequency of medication reconciliation errors (MREs) in hospitalized patients and explore the profiles of patients at greater risk. To compare the rates of errors in prescriptions written by emergency physicians and ward physicians, who each used a different prescribing tool. Prospective cross-sectional study of a convenience sample of patients admitted to medical, geriatric, and oncology wards over a period of 6 months. A pharmacist undertook the medication reconciliation report, and data were analyzed for possible associations with risk factors or prescriber type (emergency vs ward physician). A total of 148 patients were studied. Emergency physicians had prescribed for 68 (45.9%) and ward physicians for 80 (54.1%). A total of 303 MREs were detected; 113 (76.4%) patients had at least 1 error. No statistically significant differences were found between prescriber types. Factors that conferred risk for a medication error were use polypharmacy (odds ratio [OR], 3.4; 95% CI, 1.2-9.0; P=.016) and multiple chronic conditions in patients under the age of 80 years (OR, 3.9; 95% CI, 1.1-14.7; P=.039). The incidence of MREs is high regardless of whether the prescriber is an emergency or ward physician. The patients who are most at risk are those taking several medications and those under the age of 80 years who have multiple chronic conditions.

  17. Magnetic resonance angiography for patients with positional vertigo

    International Nuclear Information System (INIS)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya; Kumoi, Takeo.

    1993-01-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author)

  18. Magnetic resonance angiography for patients with positional vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya (Takarazuka City Hospital, Hyogo (Japan)); Kumoi, Takeo

    1993-11-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author).

  19. Film techniques in radiotherapy for treatment verification, determination of patient exit dose, and detection of localization error

    International Nuclear Information System (INIS)

    Haus, A.G.; Marks, J.E.

    1974-01-01

    In patient radiation therapy, it is important to know that the diseased area is included in the treatment field and that normal anatomy is properly shielded or excluded. Since 1969, a film technique developed for imaging of the complete patient radiation exposure has been applied for treatment verification and for the detection and evaluation of localization errors that may occur during treatment. The technique basically consists of placing a film under the patient during the entire radiation exposure. This film should have proper sensitivity and contrast in the exit dose exposure range encountered in radiotherapy. In this communication, we describe how various exit doses fit the characteristic curve of the film; examples of films exposed to various exit doses; the technique for using the film to determine the spatial distribution of the absorbed exit dose; and types of errors commonly detected. Results are presented illustrating that, as the frequency of use of this film technique is increased, localization error is reduced significantly

  20. The influence of the analog-to-digital conversion error on the JT-60 plasma position/shape feedback control system

    International Nuclear Information System (INIS)

    Yoshida, Michiharu; Kurihara, Kenichi

    1995-12-01

    In the plasma feedback control system (PFCS) and the direct digital controller (DDC) for the poloidal field coil power supply in the JT-60 tokamak, it is necessary to observe signals of all the poloidal field coil currents. Each of the signals, originally measured by a single sensor, is distributed to the PFCS and DDC through different cable routes and different analog-to-digital converters from each other. This produces the conversion error to the amount of several bits. Consequently, proper voltage from feedback calculation cannot be applied to the coil, and hence the control performance is possibly supposed to deteriorate to a certain extent. This paper describes how this error makes an influence on the plasma horizontal position control and how to improve the deteriorated control performance. (author)

  1. Two-dimensional errors

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This chapter addresses the extension of previous work in one-dimensional (linear) error theory to two-dimensional error analysis. The topics of the chapter include the definition of two-dimensional error, the probability ellipse, the probability circle, elliptical (circular) error evaluation, the application to position accuracy, and the use of control systems (points) in measurements

  2. Taking into account positioning errors during a three dimensional conformal radiotherapy for a non at small cells lung cancer

    International Nuclear Information System (INIS)

    Fernandez, D.; Maisonobe, J.A.; Leignel, D.; Durdux, C.; Henni, M.; Dessard-Diana, B.; Housset, M.; Giraud, P.

    2009-01-01

    Purpose: According to the report 62 of the International commission on radiation units and measurements (ICRU), the estimated target volume adds to the internal margin that takes into account the movements of the target volume during breathing, an external margin that takes into account the uncertainties of beams positioning. Our objective was to describe a method of estimated target volume calculation taking into account the technique of irradiation chosen in the service. (N.C.)

  3. SU-E-J-21: Setup Variability of Colorectal Cancer Patients Treated in the Prone Position and Dosimetric Comparison with the Supine Position

    Energy Technology Data Exchange (ETDEWEB)

    Kim, A; Foster, J; Chu, W; Karotki, A [Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, Ontario (Canada)

    2015-06-15

    Purpose: Many cancer centers treat colorectal patients in the prone position on a belly board to minimize dose to the small bowel. That may potentially Result in patient setup instability with corresponding impact on dose delivery accuracy for highly conformal techniques such as IMRT/VMAT. Two aims of this work are 1) to investigate setup accuracy of rectum patients treated in the prone position on a belly board using CBCT and 2) to evaluate dosimetric impact on bladder and small bowel of treating rectum patients in supine vs. prone position. Methods: For the setup accuracy study, 10 patients were selected. Weekly CBCTs were acquired and matched to bone. The CBCT-determined shifts were recorded. For the dosimetric study, 7 prone-setup patients and 7 supine-setup patients were randomly selected from our clinical database. Various clinically relevant dose volume histogram values were recorded for the small bowel and bladder. Results: The CBCT-determined rotational shifts had a wide variation. For the dataset acquired at the time of this writing, the ranges of rotational setup errors for pitch, roll, and yaw were [−3.6° 4.7°], [−4.3° 3.2°], and [−1.4° 1.4°]. For the dosimetric study: the small bowel V(45Gy) and mean dose for the prone position was 5.6±12.1% and 18.4±6.2Gy (ranges indicate standard deviations); for the supine position the corresponding dose values were 12.9±15.8% and 24.7±8.8Gy. For the bladder, the V(30Gy) and mean dose for prone position were 68.7±12.7% and 38.4±3.3Gy; for supine position these dose values were 77.1±13.7% and 40.7±3.1Gy. Conclusion: There is evidence of significant rotational instability in the prone position. The OAR dosimetry study indicates that there are some patients that may still benefit from the prone position, though many patients can be safely treated supine.

  4. Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Do, Gyeong Min; Jeong, Deok Yang; Kim, Young Bum

    2009-01-01

    Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07 degrees in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and

  5. Action errors, error management, and learning in organizations.

    Science.gov (United States)

    Frese, Michael; Keith, Nina

    2015-01-03

    Every organization is confronted with errors. Most errors are corrected easily, but some may lead to negative consequences. Organizations often focus on error prevention as a single strategy for dealing with errors. Our review suggests that error prevention needs to be supplemented by error management--an approach directed at effectively dealing with errors after they have occurred, with the goal of minimizing negative and maximizing positive error consequences (examples of the latter are learning and innovations). After defining errors and related concepts, we review research on error-related processes affected by error management (error detection, damage control). Empirical evidence on positive effects of error management in individuals and organizations is then discussed, along with emotional, motivational, cognitive, and behavioral pathways of these effects. Learning from errors is central, but like other positive consequences, learning occurs under certain circumstances--one being the development of a mind-set of acceptance of human error.

  6. Response to "Improving Patient Safety With Error Identification in Chemotherapy Orders by Verification Nurses"
.

    Science.gov (United States)

    Zhu, Ling-Ling; Lv, Na; Zhou, Quan

    2016-12-01

    We read, with great interest, the study by Baldwin and Rodriguez (2016), which described the role of the verification nurse and details the verification process in identifying errors related to chemotherapy orders. We strongly agree with their findings that a verification nurse, collaborating closely with the prescribing physician, pharmacist, and treating nurse, can better identify errors and maintain safety during chemotherapy administration.

  7. A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors.

    Science.gov (United States)

    Tridandapani, Srini; Ramamurthy, Senthil; Provenzale, James; Obuchowski, Nancy A; Evanoff, Michael G; Bhatti, Pamela

    2014-08-01

    To evaluate whether the presence of facial photographs obtained at the point-of-care of portable radiography leads to increased detection of wrong-patient errors. In this institutional review board-approved study, 166 radiograph-photograph combinations were obtained from 30 patients. Consecutive radiographs from the same patients resulted in 83 unique pairs (ie, a new radiograph and prior, comparison radiograph) for interpretation. To simulate wrong-patient errors, mismatched pairs were generated by pairing radiographs from different patients chosen randomly from the sample. Ninety radiologists each interpreted a unique randomly chosen set of 10 radiographic pairs, containing up to 10% mismatches (ie, error pairs). Radiologists were randomly assigned to interpret radiographs with or without photographs. The number of mismatches was identified, and interpretation times were recorded. Ninety radiologists with 21 ± 10 (mean ± standard deviation) years of experience were recruited to participate in this observer study. With the introduction of photographs, the proportion of errors detected increased from 31% (9 of 29) to 77% (23 of 30; P = .006). The odds ratio for detection of error with photographs to detection without photographs was 7.3 (95% confidence interval: 2.29-23.18). Observer qualifications, training, or practice in cardiothoracic radiology did not influence sensitivity for error detection. There is no significant difference in interpretation time for studies without photographs and those with photographs (60 ± 22 vs. 61 ± 25 seconds; P = .77). In this observer study, facial photographs obtained simultaneously with portable chest radiographs increased the identification of any wrong-patient errors, without substantial increase in interpretation time. This technique offers a potential means to increase patient safety through correct patient identification. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  8. Role of IGRT in patient positioning and verification

    International Nuclear Information System (INIS)

    Mijnheer, Ben

    2008-01-01

    Image-guided radiation therapy is 'Frequent imaging in the treatment room during a course of radiotherapy to guide the treatment process'. Instrumentation related to IGRT is highlighted. Focus of the lecture was on clinical experience gained by NKI-AVL, such as the use of EPID (electronic portal imaging devices) and CBCT (cone beam computed tomography) and their comparison: good results for head and neck and prostate/bladder patients: portal imaging was replaced by CBCT. After further investigation convincing results for lung patients were obtained: portal imaging was replaced by CBCT. Scan protocols were developed for these patient groups. Since February 2004 CBCT-based decision rules have been developed for: Head and Neck (Bony anatomy); Prostate (Bony anatomy; Soft tissue registration); Lung (Bony anatomy, Soft tissue registration); Brain (Bony anatomy); and Breast, bladder and liver (in progress). Final remarks are as follows: The introduction of various IGRT techniques allowed 3D verification of the position of target volumes and organs at risk just before or during treatment. Because the information is in 3D, or sometimes even in 4D, in principle these IGRT approaches provide more information compared to the use of 2D verification methods (e.g. EPIDs). Clinical data are becoming available to assess quantitatively for which treatment techniques IGRT approaches are advantageous compared to the use of conventional verification methods taking the additional resources (time, money, manpower) into account. (P.A.)

  9. Assessment of long-range kinematic GPS positioning errors by comparison with airborne laser altimetry and satellite altimetry

    DEFF Research Database (Denmark)

    Zhang, X.H.; Forsberg, René

    2007-01-01

    Long-range airborne laser altimetry and laser scanning (LIDAR) or airborne gravity surveys in, for example, polar or oceanic areas require airborne kinematic GPS baselines of many hundreds of kilometers in length. In such instances, with the complications of ionospheric biases, it can be a real...... challenge for traditional differential kinematic GPS software to obtain reasonable solutions. In this paper, we will describe attempts to validate an implementation of the precise point positioning (PPP) technique on an aircraft without the use of a local GPS reference station. We will compare PPP solutions...... of the Arctic Ocean north of Greenland, near-coincident in time and space with the ICESat satellite laser altimeter. Both of these flights were more than 800 km long. Comparisons between different GPS methods and four different software packages do not suggest a clear preference for any one, with the heights...

  10. Efficient Use of Automatic Exposure Control Systems in Computed Tomography Requires Correct Patient Positioning

    Energy Technology Data Exchange (ETDEWEB)

    Gudjonsdottir, J.; Jonsdottir, B. (Roentgen Domus Medica, Reykjavik (Iceland)); Svensson, J.R.; Campling, S. (Faculty of Health and Social Care, Anglia Ruskin Univ., Cambridge (United Kingdom)); Brennan, P.C. (Diagnostic Imaging, Biological Imaging Research, UCD School of Medicine and Medical Science, Univ. College Dublin, Belfield, Dublin (Ireland))

    2009-11-15

    Background: Image quality and radiation dose to the patient are important factors in computed tomography (CT). To provide constant image quality, tube current modulation (TCM) performed by automatic exposure control (AEC) adjusts the tube current to the patient's size and shape. Purpose: To evaluate the effects of patient centering on tube current-time product (mAs) and image noise. Material and Methods: An oval-shaped acrylic phantom was scanned in various off-center positions, at 30-mm intervals within a 500-mm field of view, using three different CT scanners. Acquisition parameters were similar to routine abdomen examinations at each site. The mAs was recorded and noise measured in the images. The correlation of mAs and noise with position was calculated using Pearson correlation. Results: In all three scanners, the mAs delivered by the AEC changed with y-position of the phantom (P<0.001), with correlation values of 0.98 for scanners A and B and -0.98 for scanner C. With x-position, mAs changes were 4.9% or less. As the phantom moved into the y-positions, compared with the iso-center, the mAs varied by up to +70%, -34%, and +56% in scanners A, B, and C, respectively. For scanners A and B, noise in two regions of interest in the lower part of the phantom decreased with elevation, with correlation factors from -0.95 to -0.86 (P<0.02). In the x-direction, significant noise relationships (P<0.005) were only seen in scanner A. Conclusion: This study demonstrates that patient centering markedly affects the efficacy of AEC function and that tube current changes vary between scanners. Tube position when acquiring the scout projection radiograph is decisive for the direction of the mAs change. Off-center patient positions cause errors in tube current modulation that can outweigh the dose reduction gained by AEC use, and image quality is affected

  11. Investigations on uncertainties in patient positioning for prostate treatment with EPID; Untersuchungen zur Positionierungsgenauigkeit bei Prostatakonformationsbestrahlungen mittels Portal-Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bakai, A.; Nuesslin, F. [Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany). Abt. Medizinische Physik; Paulsen, F.; Plasswilm, L.; Bamberg, M. [Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany). Abt. Strahlentherapie

    2002-02-01

    Background: Conformal radiotherapy techniques as used in prostate treatment allow to spare normal tissue by conforming the radiation fields to the shape of the planning target volume (PTV). To be able to fully utilize the advantages of these techniques correct patient positioning is an important prerequisite. This study employing an electronic portal imaging device (EPID) investigated the positioning uncertainties that occur in the pelvic region for different patient positioning devices. Patients and Methods: 15 patients with prostate cancer were irradiated with or without rectal balloon/pelvic mask at a linear accelerator with multileaf collimator (MLC). For each patient multiple portal images were taken from different directions and compared to the digitally reconstructed radiographs (DRRs) of the treatment planning system and to simulation films (Table 1, Figure 1). Results: In spite of different positioning devices, all patients showed comparable total positioning uncertainties of 4.0 mm (lateral), 4.5 mm (cranio-caudal) and 1.7 mm (dorso-ventral). The lateral positioning error was reduced for the pelvic mask patients while the cranio-caudal error increased (Table 2, Figure 2). A systematic and a random component sum up to the total positioning error, and a good estimate of the magnitudes of the two is possible from six to eight portal images (Figure 3). Conclusions: With a small number of portal images it is possible to find out the systematic and random positioning error of a patient. Knowledge of the random error can be used to resize the treatment margin which is clinically relevant since this error differs greatly for different patients (Figure 4). Image analysis with EPID is convenient, yet has some problems. For example, one only gets indirect information on the movement of the ventral rectum wall. The successful operation of positioning devices, although, needs further improvement - especially if one focuses on IMRT. (orig.) [German] Hintergrund

  12. Thresholds for human detection of patient setup errors in digitally reconstructed portal images of prostate fields

    International Nuclear Information System (INIS)

    Phillips, Brooke L.; Jiroutek, Michael R.; Tracton, Gregg; Elfervig, Michelle; Muller, Keith E.; Chaney, Edward L.

    2002-01-01

    Purpose: Computer-assisted methods to analyze electronic portal images for the presence of treatment setup errors should be studied in controlled experiments before use in the clinical setting. Validation experiments using images that contain known errors usually report the smallest errors that can be detected by the image analysis algorithm. This paper offers human error-detection thresholds as one benchmark for evaluating the smallest errors detected by algorithms. Unfortunately, reliable data are lacking describing human performance. The most rigorous benchmarks for human performance are obtained under conditions that favor error detection. To establish such benchmarks, controlled observer studies were carried out to determine the thresholds of detectability for in-plane and out-of-plane translation and rotation setup errors introduced into digitally reconstructed portal radiographs (DRPRs) of prostate fields. Methods and Materials: Seventeen observers comprising radiation oncologists, radiation oncology residents, physicists, and therapy students participated in a two-alternative forced choice experiment involving 378 DRPRs computed using the National Library of Medicine Visible Human data sets. An observer viewed three images at a time displayed on adjacent computer monitors. Each image triplet included a reference digitally reconstructed radiograph displayed on the central monitor and two DRPRs displayed on the flanking monitors. One DRPR was error free. The other DRPR contained a known in-plane or out-of-plane error in the placement of the treatment field over a target region in the pelvis. The range for each type of error was determined from pilot observer studies based on a Probit model for error detection. The smallest errors approached the limit of human visual capability. The observer was told what kind of error was introduced, and was asked to choose the DRPR that contained the error. Observer decisions were recorded and analyzed using repeated

  13. Sputum Conversion Among Patients With Smear Positive Pulmonary Tuberculosis

    Directory of Open Access Journals (Sweden)

    Soudbakhsh A R

    2003-06-01

    Full Text Available Introduction: In the patients with smear-positive pulmonary tuberculosis (TB bacteriologic assessment of sputum for detection of acid bacilli (AFB Has essential role. This evaluation is accomplished by direct sputum smear & sputum culture. These examinations must be done in regular and preferably monthly after beginning of treatment. These tests have two important aims, including, determining of treatment efficacy & duration of isolation."nMethods and Materials: Most of the studies have that classic six month regimen led to sputum smear conversion & negative sputum culture in 85% of patient. This treatment regimen has two phases, including, attack phase and maintenance phase. In the attack phase we use four drugs, including, Isoniazid (INH, Rifampin (RMP, Pyrazinamide (PZA and Ethambutol (EMB for the first 2 months and if necessary until the end of third month. In the maintenance phase we use INH and Rif for the remaining of treatment course. The main objectives of this study were to determine the time needed for smear conversion and assessment of probable factors which may influence the smear conversion until 4 months after beginning of therapy. The factors that were assessed, were, Age, nationality, sex, clinical symptoms, underlying diseases, chest radiography (number of cavities, smoking, drug abuse and concentration of AF13 in the sputum Generally, we did this cross sectional study on the patient's records, who had been observed in Imam Khomeni Hospital, west health service center and masih daneshvary hospital between."nResults: This study showed that from totally 218 patients, 138(74.6% patients had sputum conversion at the first 2 months of treatment and until the end of 3rd & 4th month this rate reached to 83.3% respectively. So in the end of fourth month only 32(14.7% patients did not show sputum smear conversion. On the other hand this study showed that two factors including presence of cavities in chest radiography

  14. Classification of radiological errors in chest radiographs, using support vector machine on the spatial frequency features of false- negative and false-positive regions

    Science.gov (United States)

    Pietrzyk, Mariusz W.; Donovan, Tim; Brennan, Patrick C.; Dix, Alan; Manning, David J.

    2011-03-01

    Aim: To optimize automated classification of radiological errors during lung nodule detection from chest radiographs (CxR) using a support vector machine (SVM) run on the spatial frequency features extracted from the local background of selected regions. Background: The majority of the unreported pulmonary nodules are visually detected but not recognized; shown by the prolonged dwell time values at false-negative regions. Similarly, overestimated nodule locations are capturing substantial amounts of foveal attention. Spatial frequency properties of selected local backgrounds are correlated with human observer responses either in terms of accuracy in indicating abnormality position or in the precision of visual sampling the medical images. Methods: Seven radiologists participated in the eye tracking experiments conducted under conditions of pulmonary nodule detection from a set of 20 postero-anterior CxR. The most dwelled locations have been identified and subjected to spatial frequency (SF) analysis. The image-based features of selected ROI were extracted with un-decimated Wavelet Packet Transform. An analysis of variance was run to select SF features and a SVM schema was implemented to classify False-Negative and False-Positive from all ROI. Results: A relative high overall accuracy was obtained for each individually developed Wavelet-SVM algorithm, with over 90% average correct ratio for errors recognition from all prolonged dwell locations. Conclusion: The preliminary results show that combined eye-tracking and image-based features can be used for automated detection of radiological error with SVM. The work is still in progress and not all analytical procedures have been completed, which might have an effect on the specificity of the algorithm.

  15. Supine vs decubitus lateral patient positioning in vertebral fracture assessment.

    Science.gov (United States)

    Paggiosi, Margaret Anne; Finigan, Judith; Peel, Nicola; Eastell, Richard; Ferrar, Lynne

    2012-01-01

    In vertebral fracture assessment (VFA), lateral scans are obtained with the patient positioned supine (C-arm densitometers) or lateral decubitus (fixed-arm densitometers). We aimed to determine the impact of positioning on image quality and fracture definition. We performed supine and decubitus lateral VFA in 50 postmenopausal women and used the algorithm-based qualitative method to identify vertebral fractures. We compared the 2 techniques for the identification of fractures (kappa analysis) and compared the numbers of unreadable vertebrae (indiscernible endplates) and vertebrae that were projected obliquely (Wilcoxon matched-pairs signed-rank test). The kappa score for agreement between the VFA techniques (to identify women with vertebral fractures) was 0.84 (95% confidence interval [CI]: 0.68-0.99), and for agreement with fracture assessments made from radiographs, kappa was 0.76 (95% CI: 0.57-0.94) for both supine and decubitus lateral VFA. There were more unreadable vertebrae with supine lateral (48 vertebrae in supine lateral compared with 14 in decubitus lateral; p=0.001), but oblique projection was less common (93 vertebrae compared with 145 in decubitus lateral; p=0.002). We conclude that there were significantly different projection effects with supine and decubitus lateral VFA, but these differences did not influence the identification of vertebral fractures in our study sample. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  16. Positive effects of massage therapy on a patient with narcolepsy.

    Science.gov (United States)

    Hill, Robyn; Baskwill, Amanda

    2013-01-01

    The purpose of this case report was to investigate the effects of massage therapy on the sleep patterns of a woman with narcolepsy. The 23-year-old woman's primary symptoms included excessive daytime sleepiness and periodic leg movements (PLM), which were associated with her diagnoses of both narcolepsy and cataplexy. Five 45-minute massage therapy treatments were administered over a five-week period. The patient's sleep patterns were recorded each week before the treatment. A final measurement was recorded in the sixth week. The sleep patterns were monitored using the Leeds Sleep Evaluation Questionnaire, which included ten visual analogue scales. The results of this case report included an improvement in getting to sleep by 148%, an improvement in quality of sleep by 1100%, an improvement in awake following sleep by 121%, and an improvement in behaviour following wakening by 28% using the Leeds Sleep Evaluation Questionnaire. This case report suggests that massage therapy had a positive effect on this patient with narcolepsy. Further research is needed to investigate the effects of massage therapy on narcolepsy and sleep patterns.

  17. A prospective international observational prevalence study on prone positioning of ARDS patients: the APRONET (ARDS Prone Position Network) study

    NARCIS (Netherlands)

    Guérin, C.; Beuret, P.; Constantin, J. M.; Bellani, G.; Garcia-Olivares, P.; Roca, O.; Meertens, J. H.; Maia, P. Azevedo; Becher, T.; Peterson, J.; Larsson, A.; Gurjar, M.; Hajjej, Z.; Kovari, F.; Assiri, A. H.; Mainas, E.; Hasan, M. S.; Morocho-Tutillo, D. R.; Baboi, L.; Chrétien, J. M.; François, G.; Ayzac, L.; Chen, L.; Brochard, L.; Mercat, A.; Hajjej, Zied; Sellami, Walid; Ferjani, M.; Gurjar, Mohan; Assiri, Amer; Al Bshabshe, Ali; Almekhlafi, Ghaleb; Mandourah, Yasser; Hasan, Mohd Shahnaz; Rai, Vineya; Marzida, M.; Corcoles Gonzalez, Virgilio; Sanchez Iniesta, Rafael; Garcia, Pablo; Garcia-Montesinos de La Peña, Manuel; Garcia Herrera, Adriana; Roca, Oriol; Garcia-de-Acilu, Marina; Masclans Enviz, Joan Ramon; Mancebo, Jordi; Heili, Sarah; Artigas Raventos, Antonio; Blanch Torra, Lluís; Roche-Campo, Ferran; Schultz, Marcus

    2018-01-01

    While prone positioning (PP) has been shown to improve patient survival in moderate to severe acute respiratory distress syndrome (ARDS) patients, the rate of application of PP in clinical practice still appears low. This study aimed to determine the prevalence of use of PP in ARDS patients (primary

  18. Error in laboratory report data for platelet count assessment in patients suspicious for dengue: a note from observation

    Directory of Open Access Journals (Sweden)

    Somsri Wiwanitkit

    2016-08-01

    Full Text Available Dengue is a common tropical infection that is still a global health threat. An important laboratory parameter for the management of dengue is platelet count. Platelet count is an useful test for diagnosis and following up on dengue. However, errors in laboratory reports can occur. This study is a retrospective analysis on laboratory report data of complete blood count in cases with suspicious dengue in a medical center within 1 month period during the outbreak season on October, 2015. According to the studied period, there were 184 requests for complete blood count for cases suspected for dengue. From those 184 laboratory report records, errors can be seen in 12 reports (6.5%. This study demonstrates that there are considerable high rate of post-analytical errors in laboratory reports. Interestingly, the platelet count in those erroneous reports can be unreliable and ineffective or problematic when it is used for the management of dengue suspicious patients.

  19. A mode of error: Immunoglobulin binding protein (a subset of anti-citrullinated proteins can cause false positive tuberculosis test results in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Maria Greenwald

    2017-12-01

    Full Text Available Citrullinated Immunoglobulin Binding Protein (BiP is a newly described autoimmune target in rheumatoid arthritis (RA, one of many cyclic citrullinated peptides(CCP or ACPA. BiP is over-expressed in RA patients causing T cell expansion and increased interferon levels during incubation for the QuantiFERON-Gold tuberculosis test (QFT-G TB. The QFT-G TB has never been validated where interferon is increased by underlying disease, as for example RA.Of ACPA-positive RA patients (n = 126, we found a 13% false-positive TB test rate by QFT-G TB. Despite subsequent biologic therapy for 3 years of all 126 RA patients, none showed evidence of TB without INH. Most of the false-positive RA patients after treatment with biologic therapy reverted to a negative QFT-G test. False TB tests correlated with ACPA level (p < 0.02.Three healthy women without arthritis or TB exposure had negative QFT-G TB. In vitro, all three tested positive every time for TB correlating to the dose of BiP or anti-BiP added, at 2 ug/ml, 5 ug/ml, 10 ug/ml, and 20 ug/ml.BiP naturally found in the majority of ACPA-positive RA patients can result in a false positive QFT-G TB. Subsequent undertreatment of RA, if biologic therapy is withheld, and overtreatment of presumed latent TB may harm patients. Keywords: Tuberculosis, IGRA, Rheumatoid arthritis, Interferon, Anti-citrullinated peptide antibody (ACPA, Immunoglobulin binding protein (BiP

  20. Detection of patient setup errors with a portal image - DRR registration software application.

    Science.gov (United States)

    Sutherland, Kenneth; Ishikawa, Masayori; Bengua, Gerard; Ito, Yoichi M; Miyamoto, Yoshiko; Shirato, Hiroki

    2011-02-18

    The purpose of this study was to evaluate a custom portal image - digitally reconstructed radiograph (DRR) registration software application. The software works by transforming the portal image into the coordinate space of the DRR image using three control points placed on each image by the user, and displaying the fused image. In order to test statistically that the software actually improves setup error estimation, an intra- and interobserver phantom study was performed. Portal images of anthropomorphic thoracic and pelvis phantoms with virtually placed irradiation fields at known setup errors were prepared. A group of five doctors was first asked to estimate the setup errors by examining the portal and DRR image side-by-side, not using the software. A second group of four technicians then estimated the same set of images using the registration software. These two groups of human subjects were then compared with an auto-registration feature of the software, which is based on the mutual information between the portal and DRR images. For the thoracic case, the average distance between the actual setup error and the estimated error was 4.3 ± 3.0 mm for doctors using the side-by-side method, 2.1 ± 2.4 mm for technicians using the registration method, and 0.8 ± 0.4mm for the automatic algorithm. For the pelvis case, the average distance between the actual setup error and estimated error was 2.0 ± 0.5 mm for the doctors using the side-by-side method, 2.5 ± 0.4 mm for technicians using the registration method, and 2.0 ± 1.0 mm for the automatic algorithm. The ability of humans to estimate offset values improved statistically using our software for the chest phantom that we tested. Setup error estimation was further improved using our automatic error estimation algorithm. Estimations were not statistically different for the pelvis case. Consistency improved using the software for both the chest and pelvis phantoms. We also tested the automatic algorithm with a

  1. Errors in the administration of intravenous medications in patients undergoing anesthesia in the operating room

    Directory of Open Access Journals (Sweden)

    Juan David Miranda

    2013-03-01

    Full Text Available Errors in medication administration have affected the anesthetic practice over the time and have become a major cause of perioperative morbidity and mortality. Among different medical specialties, anesthesiology is perhaps the most likely to make mistakes in this procedure. This is because in many places around the world, a single professional "anesthesiologist" orders, prepares and administers a drug at one time and setting. For thirty years, Cooper disclosed the first reports of critical incidents and perioperative safety scheme, and in the 90s', Chopra performed a retrospective analysis, found that medication errors are the fourth most common that results in disability in 17% and death in 8%, these being preventable errors in 51% of cases. It’s essential for the safe practice of anesthesia to establish interventions for improving prevention programs, education, research and development, enabling break traditional paradigms, with the aim of making recommendations and standardize the safe administration of drugs in this field.

  2. Quality Indicators in Laboratory Medicine: the status of the progress of IFCC Working Group "Laboratory Errors and Patient Safety" project.

    Science.gov (United States)

    Sciacovelli, Laura; Lippi, Giuseppe; Sumarac, Zorica; West, Jamie; Garcia Del Pino Castro, Isabel; Furtado Vieira, Keila; Ivanov, Agnes; Plebani, Mario

    2017-03-01

    The knowledge of error rates is essential in all clinical laboratories as it enables them to accurately identify their risk level, and compare it with those of other laboratories in order to evaluate their performance in relation to the State-of-the-Art (i.e. benchmarking) and define priorities for improvement actions. Although no activity is risk free, it is widely accepted that the risk of error is minimized by the use of Quality Indicators (QIs) managed as a part of laboratory improvement strategy and proven to be suitable monitoring and improvement tools. The purpose of QIs is to keep the error risk at a level that minimizes the likelihood of patients. However, identifying a suitable State-of-the-Art is challenging, because it calls for the knowledge of error rates measured in a variety of laboratories throughout world that differ in their organization and management, context, and the population they serve. Moreover, it also depends on the choice of the events to keep under control and the individual procedure for measurement. Although many laboratory professionals believe that the systemic use of QIs in Laboratory Medicine may be effective in decreasing errors occurring throughout the total testing process (TTP), to improve patient safety as well as to satisfy the requirements of International Standard ISO 15189, they find it difficult to maintain standardized and systematic data collection, and to promote continued high level of interest, commitment and dedication in the entire staff. Although many laboratories worldwide express a willingness to participate to the Model of QIs (MQI) project of IFCC Working Group "Laboratory Errors and Patient Safety", few systematically enter/record their own results and/or use a number of QIs designed to cover all phases of the TTP. Many laboratories justify their inadequate participation in data collection of QIs by claiming that the number of QIs included in the MQI is excessive. However, an analysis of results suggests

  3. Initial clinical experience with an interactive, video-based patient-positioning system for head and neck treatment

    International Nuclear Information System (INIS)

    Johnson, L.; Hadley, Scott W.; Milliken, Barrett D.; Pelizzari, Charles A.; Haraf, Daniel J.; Nguyen, Ai; Chen, George T.Y.

    1996-01-01

    Objective: To evaluate an interactive, video-based system for positioning head and neck patients. Materials and Methods: System hardware includes two B and W CCD cameras (mounted to provide left-lateral and AP-inferior views), zoom lenses, and a PC equipped with a frame grabber. Custom software is used to acquire and archive video images, as well as to display real-time subtraction images revealing patient misalignment in multiple views. Live subtraction images are obtained by subtracting a reference image (i.e., an image of the patient in the correct position) from real-time video. As seen in the figure, darker regions of the subtraction image indicate where the patient is currently, while lighter regions indicate where the patient should be. Adjustments in the patient's position are updated and displayed in less than 0.07s, allowing the therapist to interactively detect and correct setup discrepancies. Patients selected for study are treated BID and immobilized with conventional litecast straps attached to a baseframe which is registered to the treatment couch. Morning setups are performed by aligning litecast marks and patient anatomy to treatment room lasers. Afternoon setups begin with the same procedure, and then live subtraction images are used to fine-tune the setup. At morning and afternoon setups, video images and verification films are taken after positioning is complete. These are visually registered offline to determine the distribution of setup errors per patient, with and without video assistance. Results: Without video assistance, the standard deviation of setup errors typically ranged from 5 to 7mm and was patient-dependent. With video assistance, standard deviations are reduced to 1 to 4mm, with the result depending on patient coopertiveness and the length of time spent fine-tuning the setups. At current levels of experience, 3 to 4mm accuracy is easily achieved in about 30s, while 1 to 3mm accuracy is achieved in about 1 to 2 minutes. Studies

  4. Prona positioning in patients submitted to myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Cunha, C.J.; Ferreira, F.C.L.; Dullius, M.A.; Souza, S.O.; Souza, D.N.

    2011-01-01

    The myocardium perfusion scintigraphy corresponds at the nuclear medicine to one of best diagnostic methods for myocardium diseases. However, artefacts generated by the diaphragmatic tissue can induce to false positive diagnostic when does not occurs association of the image in supine position with the prone position. Images acquired at the two positions were analysed and the evaluation of tomographic images were estimation and consequently, a more completed diagnostic

  5. Measurement error of a simplified protocol for quantitative sensory tests in chronic pain patients

    DEFF Research Database (Denmark)

    Müller, Monika; Biurrun Manresa, José; Limacher, Andreas

    2017-01-01

    BACKGROUND AND OBJECTIVES: Large-scale application of Quantitative Sensory Tests (QST) is impaired by lacking standardized testing protocols. One unclear methodological aspect is the number of records needed to minimize measurement error. Traditionally, measurements are repeated 3 to 5 times...

  6. special position for the anaesthetic management of a patient with ...

    African Journals Online (AJOL)

    2010-03-01

    Mar 1, 2010 ... was too huge to allow adoption of the supine position for induction of anaesthesia. In order to achieve a suit- ... Keywords: Anaesthetic position, Operating table, Gi- ant mass, Airway management, General .... tions of stroke and death related to shoulder sur- gery in the sitting position. Arthroscopy 2008.

  7. The application of SHERPA (Systematic Human Error Reduction and Prediction Approach) in the development of compensatory cognitive rehabilitation strategies for stroke patients with left and right brain damage.

    Science.gov (United States)

    Hughes, Charmayne M L; Baber, Chris; Bienkiewicz, Marta; Worthington, Andrew; Hazell, Alexa; Hermsdörfer, Joachim

    2015-01-01

    Approximately 33% of stroke patients have difficulty performing activities of daily living, often committing errors during the planning and execution of such activities. The objective of this study was to evaluate the ability of the human error identification (HEI) technique SHERPA (Systematic Human Error Reduction and Prediction Approach) to predict errors during the performance of daily activities in stroke patients with left and right hemisphere lesions. Using SHERPA we successfully predicted 36 of the 38 observed errors, with analysis indicating that the proportion of predicted and observed errors was similar for all sub-tasks and severity levels. HEI results were used to develop compensatory cognitive strategies that clinicians could employ to reduce or prevent errors from occurring. This study provides evidence for the reliability and validity of SHERPA in the design of cognitive rehabilitation strategies in stroke populations.

  8. Technical study of craniospinal irradiation in pediatric patients with patient position and field matching

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Masanori; Ise, Toshihide; Umezu, Mikio [Kangawa Children' s Medical Center, Yokohama (Japan); Hioki, Minoru

    2000-05-01

    Craniospinal irradiation (CSI) in leukemia and medulloblastoma patients is usually a three-field technique that involves parallel-opposed lateral cranial fields adjacent and orthogonal to a posterior spinal field. Since sedation is often necessary for pediatric patients, the supine position is more favorable than the prone position for respiratory monitoring. We practiced CSI in the supine position in one case of leukemia and three cases of medulloblastoma. Each location of the isocenter was determined by moving the couch to fit the center of the CSI on the basis of incisura intertragica. The angles of collimator rotation and couch rotation were calculated according to each treatment field size. The junction was also moved 2 cm day by day during the course of treatment so that over- and underdose at the junction would be prevented. The supine position did not allow us to visually confirm the proper junction between the lateral cranial fields and the spinal field. However, we succeeded in practicing complete conjunction between the fields by proper collimator and couch rotations on the assessment of the film-dose method. CSI in the supine position is naturally comfortable for pediatric patients and seems effective in pediatric treatments, which often require respiratory monitoring for sedation. (author)

  9. Seroprevalence of Epstein-Barr virus among HIV positive patients moreover and its association with CD4 positive lymphocyte count.

    Directory of Open Access Journals (Sweden)

    Alireza Abdollahi

    2014-12-01

    Full Text Available Opportunistic infections are the leading cause of hospitalization and morbidity in human immunodeficiency virus (HIV positive patients and are the most common cause of death between them. We aimed to measure IgG antibody against EBV viral capsid antigen (EBV-VCA IgG to determine the seroprevalence of this infection in HIV-positive population. A case-control study between September 2011 and October 2012 was conducted in a teaching hospital enrolling 114 HIV-positive patients as case group and 114 healthy individuals as control with similar age and sex. Enzyme-linked immunosurbant assay (ELISA technique was used for determination of EBV-VAC IgG in obtained samples. Of 114 serum samples obtained from HIV-positive patients, 103 (90.4% samples were found positive for EBV-VCA IgG antibody. There was no significant difference in seroprevalence of EBV VCA IgG antibody between patients received antiretroviral therapy and naive patients (91.5% vs. 87.5%, P>0.05. There was no statistically significant difference in EBV-VCA IgG seroprevalence between three groups of CD4+ in HIV positive group. In conclusion current study showed that seroprevalence of EBV in HIV-positive patients is higher than HIV-negative healthy participants; however, administration of HAART and CD4+ lymphocyte count did not reveal a significant effect in seroprevalence of EBV. Due to the significance of this virus in mortality and morbidity and causing certain malignancies in patients with AIDS, these patients are strongly recommended to be tested for this virus.

  10. Positive Affect and Health Behaviors Across 5 Years in Patients With Coronary Heart Disease: The Heart and Soul Study.

    Science.gov (United States)

    Sin, Nancy L; Moskowitz, Judith Tedlie; Whooley, Mary A

    2015-01-01

    Positive psychological states are linked to superior health and longevity, possibly due to behavioral factors. We evaluated cross-sectional and 5-year associations between positive affect and health behaviors in patients with coronary heart disease (CHD). Outpatients with CHD reported positive affect, physical activity, sleep quality, medication adherence, cigarette smoking, and alcohol use at baseline (n = 1022) and 5 years later (n = 662). Covariates in regression analyses included demographics, cardiac disease severity, and depressive symptoms. At baseline, higher positive affect (per 1 standard deviation) was associated with better health behaviors: physical activity (odds ratio [OR] = 1.52, 95% 95% confidence interval [CI] = 1.30-1.77, p positive affect did not predict health behaviors at follow-up, accounting for baseline behaviors. However, increases in positive affect across 5 years co-occurred with improvements in physical activity (B = 0.023, standard error [SE] = 0.008, p = .002), sleep quality (B = 0.011, SE = 0.005, p = .039), and medication adherence (B = 0.014, SE = 0.004, p Positive affect was associated with health behaviors among patients with CHD. Efforts to sustain or enhance positive affect may be promising for promoting better health behaviors.

  11. ESTRO ACROP guidelines for positioning, immobilisation and position verification of head and neck patients for radiation therapists

    Directory of Open Access Journals (Sweden)

    Michelle Leech

    2017-03-01

    Full Text Available Background and purpose: Over the last decade, the management of locally advanced head and neck cancers (HNCs has seen a substantial increase in the use of chemoradiation. These guidelines have been developed to assist Radiation TherapisTs (RTTs in positioning, immobilisation and position verification for head and neck cancer patients. Materials and methods: A critical review of the literature was undertaken by the writing committee.Based on the literature review, a survey was developed to ascertain the current positioning, immobilisation and position verification methods for head and neck radiation therapy across Europe. The survey was translated into Italian, German, Greek, Portuguese, Russian, Croatian, French and Spanish.Guidelines were subsequently developed by the writing committee. Results: Results from the survey indicated that a wide variety of treatment practices and treatment verification protocols are in operation for head and neck cancer patients across Europe currently.The guidelines developed are based on the experience and expertise of the writing committee, remaining cognisant of the variations in imaging and immobilisation techniques used currently in Europe. Conclusions: These guidelines have been developed to provide RTTs with guidance on positioning, immobilisation and position verification of HNC patients. The guidelines will also provide RTTs with the means to critically reflect on their own daily clinical practice with this patient group. Keywords: Head and neck, Immobilisation, Positioning, Verification

  12. The influence of patient positioning in breast CT on breast tissue coverage and patient comfort

    Energy Technology Data Exchange (ETDEWEB)

    Roessler, A.C.; Althoff, F.; Kalender, W. [Erlangen Univ. (Germany). Inst. of Medical Physics; Wenkel, E. [University Hospital of Erlangen (Germany). Radiological Inst.

    2015-02-15

    The presented study aimed at optimizing a patient table design for breast CT (BCT) systems with respect to breast tissue coverage and patient comfort. Additionally, the benefits and acceptance of an immobilization device for BCT using underpressure were evaluated. Three different study parts were carried out. In a positioning study women were investigated on an MRI tabletop with exchangeable inserts (flat and cone-shaped with different opening diameters) to evaluate their influence on breast coverage and patient comfort in various positioning alternatives. Breast length and volume were calculated to compare positioning modalities including various opening diameters and forms. In the second study part, an underpressure system was tested for its functionality and comfort on a stereotactic biopsy table mimicking a future CT scanner table. In the last study part, this system was tested regarding breast tissue coverage. Best results for breast tissue coverage were shown for cone-shaped table inserts with an opening of 180 mm. Flat inserts did not provide complete coverage of breast tissue. The underpressure system showed robust function and tended to pull more breast tissue into the field of view. Patient comfort was rated good for all table inserts, with highest ratings for cone-shaped inserts. Cone-shaped tabletops appeared to be adequate for BCT systems and to allow imaging of almost the complete breast. An underpressure system proved promising for the fixation of the breast during imaging and increased coverage. Patient comfort appears to be adequate.

  13. Positive Predictive Value of True Bacteremia according to the Number of Positive Culture Sets in Adult Patients.

    Science.gov (United States)

    Kitaura, Tsuyoshi; Chikumi, Hiroki; Fujiwara, Hiromitsu; Okada, Kensaku; Hayabuchi, Tatsuya; Nakamoto, Masaki; Takata, Miyako; Yamasaki, Akira; Igishi, Tadashi; Burioka, Naoto; Shimizu, Eiji

    2014-12-01

    Performing multiple blood culture sets simultaneously is a standard blood culture methodology, although it is often difficult to distinguish true bacteremia from contamination when only one of several blood culture sets is positive. This study clarified the relationship between the number of positive blood culture sets and clinical significance in patients with positive blood culture. Patients aged 18 years and over with at least 1 positive blood culture were enrolled. Positive blood culture episodes were categorized from clinical records as true bacteremia, contamination, or unknown clinical significance. The associations among episodes of true bacteremia, isolated bacteria, the number of positive blood culture sets from among the performed sets, and the clinical background of patients were analyzed. Among a total of 407 episodes, 262, 67 and 78 were true bacteremia, contamination and unknown clinical significance, respectively. The positive predictive values (PPVs) of 1 out of 1, 1 out of 2 and 2 out of 2 positive sets in cases of Staphylococcus aureus, were 81.3%, 50% and 100% respectively; those in cases of coagulase-negative Staphylococci were 20.5%, 10.8% and 63.5%, respectively. Almost all cases of Escherichia coli, Pseudomonas aeruginosa, Klebsiella species and Candida species were true bacteremia. The probability of true bacteremia was strongly associated with recent surgery in multivariate analysis (P sets from among the performed sets varies by microorganism. Therefore, PPVs calculated using this method may help physicians distinguish true bacteremia from contamination.

  14. Time-order errors and standard-position effects in duration discrimination: An experimental study and an analysis by the sensation-weighting model.

    Science.gov (United States)

    Hellström, Åke; Rammsayer, Thomas H

    2015-10-01

    Studies have shown that the discriminability of successive time intervals depends on the presentation order of the standard (St) and the comparison (Co) stimuli. Also, this order affects the point of subjective equality. The first effect is here called the standard-position effect (SPE); the latter is known as the time-order error. In the present study, we investigated how these two effects vary across interval types and standard durations, using Hellström's sensation-weighting model to describe the results and relate them to stimulus comparison mechanisms. In Experiment 1, four modes of interval presentation were used, factorially combining interval type (filled, empty) and sensory modality (auditory, visual). For each mode, two presentation orders (St-Co, Co-St) and two standard durations (100 ms, 1,000 ms) were used; half of the participants received correctness feedback, and half of them did not. The interstimulus interval was 900 ms. The SPEs were negative (i.e., a smaller difference limen for St-Co than for Co-St), except for the filled-auditory and empty-visual 100-ms standards, for which a positive effect was obtained. In Experiment 2, duration discrimination was investigated for filled auditory intervals with four standards between 100 and 1,000 ms, an interstimulus interval of 900 ms, and no feedback. Standard duration interacted with presentation order, here yielding SPEs that were negative for standards of 100 and 1,000 ms, but positive for 215 and 464 ms. Our findings indicate that the SPE can be positive as well as negative, depending on the interval type and standard duration, reflecting the relative weighting of the stimulus information, as is described by the sensation-weighting model.

  15. Modelling of the X , Y , Z positioning errors and uncertainty evaluation for the LNE’s mAFM using the Monte Carlo method

    International Nuclear Information System (INIS)

    Ceria, Paul; Ducourtieux, Sebastien; Boukellal, Younes; Feltin, Nicolas; Allard, Alexandre; Fischer, Nicolas

    2017-01-01

    In order to evaluate the uncertainty budget of the LNE’s mAFM, a reference instrument dedicated to the calibration of nanoscale dimensional standards, a numerical model has been developed to evaluate the measurement uncertainty of the metrology loop involved in the XYZ positioning of the tip relative to the sample. The objective of this model is to overcome difficulties experienced when trying to evaluate some uncertainty components which cannot be experimentally determined and more specifically, the one linked to the geometry of the metrology loop. The model is based on object-oriented programming and developed under Matlab. It integrates one hundred parameters that allow the control of the geometry of the metrology loop without using analytical formulae. The created objects, mainly the reference and the mobile prism and their mirrors, the interferometers and their laser beams, can be moved and deformed freely to take into account several error sources. The Monte Carlo method is then used to determine the positioning uncertainty of the instrument by randomly drawing the parameters according to their associated tolerances and their probability density functions (PDFs). The whole process follows Supplement 2 to ‘The Guide to the Expression of the Uncertainty in Measurement’ (GUM). Some advanced statistical tools like Morris design and Sobol indices are also used to provide a sensitivity analysis by identifying the most influential parameters and quantifying their contribution to the XYZ positioning uncertainty. The approach validated in the paper shows that the actual positioning uncertainty is about 6 nm. As the final objective is to reach 1 nm, we engage in a discussion to estimate the most effective way to reduce the uncertainty. (paper)

  16. Modelling of the X,Y,Z positioning errors and uncertainty evaluation for the LNE’s mAFM using the Monte Carlo method

    Science.gov (United States)

    Ceria, Paul; Ducourtieux, Sebastien; Boukellal, Younes; Allard, Alexandre; Fischer, Nicolas; Feltin, Nicolas

    2017-03-01

    In order to evaluate the uncertainty budget of the LNE’s mAFM, a reference instrument dedicated to the calibration of nanoscale dimensional standards, a numerical model has been developed to evaluate the measurement uncertainty of the metrology loop involved in the XYZ positioning of the tip relative to the sample. The objective of this model is to overcome difficulties experienced when trying to evaluate some uncertainty components which cannot be experimentally determined and more specifically, the one linked to the geometry of the metrology loop. The model is based on object-oriented programming and developed under Matlab. It integrates one hundred parameters that allow the control of the geometry of the metrology loop without using analytical formulae. The created objects, mainly the reference and the mobile prism and their mirrors, the interferometers and their laser beams, can be moved and deformed freely to take into account several error sources. The Monte Carlo method is then used to determine the positioning uncertainty of the instrument by randomly drawing the parameters according to their associated tolerances and their probability density functions (PDFs). The whole process follows Supplement 2 to ‘The Guide to the Expression of the Uncertainty in Measurement’ (GUM). Some advanced statistical tools like Morris design and Sobol indices are also used to provide a sensitivity analysis by identifying the most influential parameters and quantifying their contribution to the XYZ positioning uncertainty. The approach validated in the paper shows that the actual positioning uncertainty is about 6 nm. As the final objective is to reach 1 nm, we engage in a discussion to estimate the most effective way to reduce the uncertainty.

  17. Target volume shape variation during irradiation of rectal cancer patients in supine position: Comparison with prone position

    International Nuclear Information System (INIS)

    Nijkamp, Jasper; Jong, Rianne de; Sonke, Jan-Jakob; Vliet, Corine van; Marijnen, Corrie

    2009-01-01

    Purpose: To quantify the inter-fraction shape variation of the mesorectum for rectal cancer patients treated with 5 x 5 Gy in supine position and compare it to variation in prone position. Methods and materials: For 28 patients a planning CT (pCT) and five daily cone-beam-CT (CBCT) scans were acquired in supine position. The mesorectal part of the CTV (MesoRect) was delineated on all scans. The shape variation was quantified by the distance between the pCT- and the CBCT delineations and stored in surface maps after online setup correction. Data were analyzed for male and female patients separately and compared to prone data. Results: A large range of systematic, 1-8 mm (1SD), and random, 1-5 mm, shape variation was found, comparable to prone patients. Random-shape variation was comparable for male and female patients, while systematic variation was 3 mm larger for female patients. Conclusions: Shape variation of the MesoRect is substantial, heterogeneous and different between male and female patients. Differences between supine and prone orientation, however, are small. Clinical margins should be differentiated in position along the cranio-caudal axis, in anterior-posterior direction and for gender. Margins should also be increased, even when online setup correction is used. Due to the small margin differences between prone and supine treatments, the setup choice should be determined on dose to the organs at risk.

  18. Is ExacTrac x-ray system an alternative to CBCT for positioning patients with head and neck cancers?

    International Nuclear Information System (INIS)

    Clemente, Stefania; Chiumento, Costanza; Fiorentino, Alba; Cozzolino, Mariella; Oliviero, Caterina; Califano, Giorgia; Caivano, Rocchina; Fusco, Vincenzo; Simeon, Vittorio

    2013-01-01

    Purpose: To evaluate the usefulness of a six-degrees-of freedom (6D) correction using ExacTrac robotics system in patients with head-and-neck (HN) cancer receiving radiation therapy.Methods: Local setup accuracy was analyzed for 12 patients undergoing intensity-modulated radiation therapy (IMRT). Patient position was imaged daily upon two different protocols, cone-beam computed tomography (CBCT), and ExacTrac (ET) images correction. Setup data from either approach were compared in terms of both residual errors after correction and punctual displacement of selected regions of interest (Mandible, C2, and C6 vertebral bodies).Results: On average, both protocols achieved reasonably low residual errors after initial correction. The observed differences in shift vectors between the two protocols showed that CBCT tends to weight more C2 and C6 at the expense of the mandible, while ET tends to average more differences among the different ROIs.Conclusions: CBCT, even without 6D correction capabilities, seems preferable to ET for better consistent alignment and the capability to see soft tissues. Therefore, in our experience, CBCT represents a benchmark for positioning head and neck cancer patients

  19. Hemispheric Asymmetries in Striatal Reward Responses Relate to Approach-Avoidance Learning and Encoding of Positive-Negative Prediction Errors in Dopaminergic Midbrain Regions.

    Science.gov (United States)

    Aberg, Kristoffer Carl; Doell, Kimberly C; Schwartz, Sophie

    2015-10-28

    Some individuals are better at learning about rewarding situations, whereas others are inclined to avoid punishments (i.e., enhanced approach or avoidance learning, respectively). In reinforcement learning, action values are increased when outcomes are better than predicted (positive prediction errors [PEs]) and decreased for worse than predicted outcomes (negative PEs). Because actions with high and low values are approached and avoided, respectively, individual differences in the neural encoding of PEs may influence the balance between approach-avoidance learning. Recent correlational approaches also indicate that biases in approach-avoidance learning involve hemispheric asymmetries in dopamine function. However, the computational and neural mechanisms underpinning such learning biases remain unknown. Here we assessed hemispheric reward asymmetry in striatal activity in 34 human participants who performed a task involving rewards and punishments. We show that the relative difference in reward response between hemispheres relates to individual biases in approach-avoidance learning. Moreover, using a computational modeling approach, we demonstrate that better encoding of positive (vs negative) PEs in dopaminergic midbrain regions is associated with better approach (vs avoidance) learning, specifically in participants with larger reward responses in the left (vs right) ventral striatum. Thus, individual dispositions or traits may be determined by neural processes acting to constrain learning about specific aspects of the world. Copyright © 2015 the authors 0270-6474/15/3514491-10$15.00/0.

  20. Non-topography-guided PRK combined with CXL for the correction of refractive errors in patients with early stage keratoconus.

    Science.gov (United States)

    Fadlallah, Ali; Dirani, Ali; Chelala, Elias; Antonios, Rafic; Cherfan, George; Jarade, Elias

    2014-10-01

    To evaluate the safety and clinical outcome of combined non-topography-guided photorefractive keratectomy (PRK) and corneal collagen cross-linking (CXL) for the treatment of mild refractive errors in patients with early stage keratoconus. A retrospective, nonrandomized study of patients with early stage keratoconus (stage 1 or 2) who underwent simultaneous non-topography-guided PRK and CXL. All patients had at least 2 years of follow-up. Data were collected preoperatively and postoperatively at the 6-month, 1-year, and 2-year follow-up visit after combined non-topography-guided PRK and CXL. Seventy-nine patients (140 eyes) were included in the study. Combined non-topography-guided PRK and CXL induced a significant improvement in both visual acuity and refraction. Uncorrected distance visual acuity significantly improved from 0.39 ± 0.22 logMAR before combined non-topography-guided PRK and CXL to 0.12 ± 0.14 logMAR at the last follow-up visit (P PRK and CXL (P PRK and CXL is an effective and safe option for correcting mild refractive error and improving visual acuity in patients with early stable keratoconus. Copyright 2014, SLACK Incorporated.

  1. Mixing of multi-modal images for conformational radiotherapy: application to patient re positioning; Fusion d`images multi-modales pour la radiotherapie conformationnelle: application au repositionnement du patient

    Energy Technology Data Exchange (ETDEWEB)

    Vassal, P

    1998-06-29

    This study shows a procedure of patient re positioning by comparative evaluation between the position of the patient and the theoretical expected position of the patient; the stagger between the two information gives the error of installation in translation and rotation. A correction is calculated and applied to the treatment environment (position and orientation of the patient, position and orientation of the irradiation source). The control system allows to determine the precise position of the tumor volume. The echography allows to determine the position of an organ.The surface captor is used to localize the tumors of the face or of the brain, with the respect to the face, the acquisition and the treatment of information take only few minutes. The X rays imager is applied for the localization of bones structures. (N.C.)

  2. Assessment on tracking error performance of Cascade P/PI, NPID and N-Cascade controller for precise positioning of xy table ballscrew drive system

    International Nuclear Information System (INIS)

    Abdullah, L; Jamaludin, Z; Rafan, N A; Jamaludin, J; Chiew, T H

    2013-01-01

    At present, positioning plants in machine tools are looking for high degree of accuracy and robustness attributes for the purpose of compensating various disturbance forces. The objective of this paper is to assess the tracking performance of Cascade P/PI, Nonlinear PID (NPID) and Nonlinear cascade (N-Cascade) controller with the existence of disturbance forces in the form of cutting forces. Cutting force characteristics at different cutting parameters; such as spindle speed rotations is analysed using Fast Fourier Transform. The tracking performance of a Nonlinear cascade controller in presence of these cutting forces is compared with NPID controller and Cascade P/PI controller. Robustness of these controllers in compensating different cutting characteristics is compared based on reduction in the amplitudes of cutting force harmonics using Fast Fourier Transform. It is found that the N-cascade controller performs better than both NPID controller and Cascade P/PI controller. The average percentage error reduction between N-cascade controller and Cascade P/PI controller is about 65% whereas the average percentage error reduction between cascade controller and NPID controller is about 82% at spindle speed of 3000 rpm spindle speed rotation. The finalized design of N-cascade controller could be utilized further for machining application such as milling process. The implementation of N-cascade in machine tools applications will increase the quality of the end product and the productivity in industry by saving the machining time. It is suggested that the range of the spindle speed could be made wider to accommodate the needs for high speed machining

  3. Inhibiting HER3-mediated tumor cell growth with affibody molecules engineered to low picomolar affinity by position-directed error-prone PCR-like diversification.

    Science.gov (United States)

    Malm, Magdalena; Kronqvist, Nina; Lindberg, Hanna; Gudmundsdotter, Lindvi; Bass, Tarek; Frejd, Fredrik Y; Höidén-Guthenberg, Ingmarie; Varasteh, Zohreh; Orlova, Anna; Tolmachev, Vladimir; Ståhl, Stefan; Löfblom, John

    2013-01-01

    The HER3 receptor is implicated in the progression of various cancers as well as in resistance to several currently used drugs, and is hence a potential target for development of new therapies. We have previously generated Affibody molecules that inhibit heregulin-induced signaling of the HER3 pathways. The aim of this study was to improve the affinity of the binders to hopefully increase receptor inhibition efficacy and enable a high receptor-mediated uptake in tumors. We explored a novel strategy for affinity maturation of Affibody molecules that is based on alanine scanning followed by design of library diversification to mimic the result from an error-prone PCR reaction, but with full control over mutated positions and thus less biases. Using bacterial surface display and flow-cytometric sorting of the maturation library, the affinity for HER3 was improved more than 30-fold down to 21 pM. The affinity is among the higher that has been reported for Affibody molecules and we believe that the maturation strategy should be generally applicable for improvement of affinity proteins. The new binders also demonstrated an improved thermal stability as well as complete refolding after denaturation. Moreover, inhibition of ligand-induced proliferation of HER3-positive breast cancer cells was improved more than two orders of magnitude compared to the previously best-performing clone. Radiolabeled Affibody molecules showed specific targeting of a number of HER3-positive cell lines in vitro as well as targeting of HER3 in in vivo mouse models and represent promising candidates for future development of targeted therapies and diagnostics.

  4. Effect of socioeconomic position on patient outcome after hysterectomy

    DEFF Research Database (Denmark)

    Daugbjerg, Signe B; Cesaroni, Giulia; Ottesen, Bent

    2014-01-01

    OBJECTIVE: To investigate the association between socioeconomic position (assessed by education, employment and income) and complications following hysterectomy and assess the role of lifestyle, co-morbidity and clinical conditions on the relationship. DESIGN: Register-based cohort study. SETTING...... significantly higher odds of complications following hysterectomy compared with women with a high socioeconomic position. Unhealthy lifestyle and presence of co-morbidity in women with low socioeconomic position partially explains the differences in complications.......OBJECTIVE: To investigate the association between socioeconomic position (assessed by education, employment and income) and complications following hysterectomy and assess the role of lifestyle, co-morbidity and clinical conditions on the relationship. DESIGN: Register-based cohort study. SETTING...... and employed women. Furthermore, unemployed women had higher odds of hospitalization >4 days than women in employment. Lifestyle factors (smoking and body mass index) and co-morbidity status seemed to explain most of the social differences. However, an association between women with less than high school...

  5. Lumbar Lordosis of Spinal Stenosis Patients during Intraoperative Prone Positioning

    OpenAIRE

    Lee, Su-Keon; Lee, Seung-Hwan; Song, Kyung-Sub; Park, Byung-Moon; Lim, Sang-Youn; Jang, Geun; Lee, Beom-Seok; Moon, Seong-Hwan; Lee, Hwan-Mo

    2016-01-01

    Background To evaluate the effect of spondylolisthesis on lumbar lordosis on the OSI (Jackson; Orthopaedic Systems Inc.) frame. Restoration of lumbar lordosis is important for maintaining sagittal balance. Physiologic lumbar lordosis has to be gained by intraoperative prone positioning with a hip extension and posterior instrumentation technique. There are some debates about changing lumbar lordosis on the OSI frame after an intraoperative prone position. We evaluated the effect of spondyloli...

  6. Feelings of hopelessness in stable HIV-positive patients on antiretrovirals

    Directory of Open Access Journals (Sweden)

    M Y H Moosa

    2010-04-01

    Full Text Available Aim. The coping skills and styles individuals utilise to deal with the stress of HIV infection greatly influence the psychological impact of this illness and potential consequent feelings of hopelessness. The aim of this study was to describe levels of hopelessness in a group of stable, non-depressed HIV-positive patients receiving antiretroviral therapy, and factors associated with hopelessness. Method. Thirty randomly selected non-depressed patients (according to Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-IV criteria were included in this study. Demographic and other data were obtained from all subjects, who also completed the Beck’s Hopelessness Scale (BHS. The 20 true-false items of the BHS (29 measured three major aspects of hopelessness, which was interpreted on the total scale score as follows: ≤3 minimal, and >3 significant. Results. The study population comprised 30 patients with a mean age of 37.9 years (standard error (SE 1.18 ( range 28 - 51 years. The mean BHS score was 4.03 (SE 0.55, with a range from 0 to 12. There were no statistically significant correlations between BHS scores of the study population and gender, marital status, employment status, level of education, years since the diagnosis of HIV, or number of children (p>0.05. Eighteen subjects (60% scored 3 or less on the BHS, considered minimal levels of hopelessness. However, 12 (40% scored more than 3, which is considered significant; of these 23% had scores of 7 or more. There was no statistically significant association between BHS scores and gender, employment status, level of education, number of children or number of years since diagnosis (p>0.05. However, patients who were married or living with partners were statistically more likely to score higher on the hopelessness scale compared with those who were single (p

  7. Using Healthcare Failure Mode and Effect Analysis to reduce medication errors in the process of drug prescription, validation and dispensing in hospitalised patients.

    Science.gov (United States)

    Vélez-Díaz-Pallarés, Manuel; Delgado-Silveira, Eva; Carretero-Accame, María Emilia; Bermejo-Vicedo, Teresa

    2013-01-01

    To identify actions to reduce medication errors in the process of drug prescription, validation and dispensing, and to evaluate the impact of their implementation. A Health Care Failure Mode and Effect Analysis (HFMEA) was supported by a before-and-after medication error study to measure the actual impact on error rate after the implementation of corrective actions in the process of drug prescription, validation and dispensing in wards equipped with computerised physician order entry (CPOE) and unit-dose distribution system (788 beds out of 1080) in a Spanish university hospital. The error study was carried out by two observers who reviewed medication orders on a daily basis to register prescription errors by physicians and validation errors by pharmacists. Drugs dispensed in the unit-dose trolleys were reviewed for dispensing errors. Error rates were expressed as the number of errors for each process divided by the total opportunities for error in that process times 100. A reduction in prescription errors was achieved by providing training for prescribers on CPOE, updating prescription procedures, improving clinical decision support and automating the software connection to the hospital census (relative risk reduction (RRR), 22.0%; 95% CI 12.1% to 31.8%). Validation errors were reduced after optimising time spent in educating pharmacy residents on patient safety, developing standardised validation procedures and improving aspects of the software's database (RRR, 19.4%; 95% CI 2.3% to 36.5%). Two actions reduced dispensing errors: reorganising the process of filling trolleys and drawing up a protocol for drug pharmacy checking before delivery (RRR, 38.5%; 95% CI 14.1% to 62.9%). HFMEA facilitated the identification of actions aimed at reducing medication errors in a healthcare setting, as the implementation of several of these led to a reduction in errors in the process of drug prescription, validation and dispensing.

  8. Fast time-of-flight camera based surface registration for radiotherapy patient positioning

    International Nuclear Information System (INIS)

    Placht, Simon; Stancanello, Joseph; Schaller, Christian; Balda, Michael; Angelopoulou, Elli

    2012-01-01

    Purpose: This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. Methods: A novel preregistration algorithm, based on translation and rotation-invariant features representing surface structures, was developed. Using these features, corresponding three-dimensional points were computed in order to determine initial registration parameters. These parameters became a robust input to an accelerated version of the iterative closest point (ICP) algorithm for the fine-tuning of the registration result. Distance calibration and Kalman filtering were used to compensate for ToF-camera dependent noise. Additionally, the advantage of using the feature based preregistration over an ''ICP only'' strategy was evaluated, as well as the robustness of the rigid-transformation-based method to deformation. Results: The proposed surface registration method was validated using phantom data. A mean target registration error (TRE) for translations and rotations of 1.62 ± 1.08 mm and 0.07 deg. ± 0.05 deg., respectively, was achieved. There was a temporal delay of about 65 ms in the registration output, which can be seen as negligible considering the dynamics of biological systems. Feature based preregistration allowed for accurate and robust registrations even at very large initial displacements. Deformations affected the accuracy of the results, necessitating particular care in cases of deformed surfaces. Conclusions: The proposed solution is able to solve surface registration problems with an accuracy suitable for radiotherapy cases where external surfaces offer primary or complementary information to patient positioning. The system shows promising dynamic properties for its use in gating/tracking applications. The overall system is competitive with commonly-used surface registration

  9. Patient position alters attenuation effects in multipinhole cardiac SPECT.

    Science.gov (United States)

    Timmins, Rachel; Ruddy, Terrence D; Wells, R Glenn

    2015-03-01

    Dedicated cardiac cameras offer improved sensitivity over conventional SPECT cameras. Sensitivity gains are obtained by large numbers of detectors and novel collimator arrangements such as an array of multiple pinholes that focus on the heart. Pinholes lead to variable amounts of attenuation as a source is moved within the camera field of view. This study evaluated the effects of this variable attenuation on myocardial SPECT images. Computer simulations were performed for a set of nine point sources distributed in the left ventricular wall (LV). Sources were placed at the location of the heart in both an anthropomorphic and a water-cylinder computer phantom. Sources were translated in x, y, and z by up to 5 cm from the center. Projections were simulated with and without attenuation and the changes in attenuation were compared. A LV with an inferior wall defect was also simulated in both phantoms over the same range of positions. Real camera data were acquired on a Discovery NM530c camera (GE Healthcare, Haifa, Israel) for five min in list-mode using an anthropomorphic phantom (DataSpectrum, Durham, NC) with 100 MBq of Tc-99m in the LV. Images were taken over the same range of positions as the simulations and were compared based on the summed perfusion score (SPS), defect width, and apparent defect uptake for each position. Point sources in the water phantom showed absolute changes in attenuation of ≤8% over the range of positions and relative changes of ≤5% compared to the apex. In the anthropomorphic computer simulations, absolute change increased to 20%. The changes in relative attenuation caused a change in SPS of position-dependent changes were removed with attenuation correction. Translation of a source relative to a multipinhole camera caused only small changes in homogeneous phantoms with SPS changing position-dependent changes in attenuation.

  10. Extent and Determinants of Error in Doctors' Prognoses in Terminally Ill Patients: Prospective Cohort Study

    OpenAIRE

    Lamont, Elizabeth; Christakis, Nicholas

    2000-01-01

    Objective: To describe doctors' prognostic accuracy in terminally ill patients and to evaluate the determinants of that accuracy. Design: Prospective cohort study. Setting: Five outpatient hospice programmes in Chicago. Participants: 343 doctors provided survival estimates for 468 terminally ill patients at the time of hospice referral. Main outcome measures: Patients' estimated and actual survival. Results: Median survival was 24 days. Only 20% (92/468) of predictions were acc...

  11. Where Are Patients Positioned in Your Seamless Care Strategies?

    Science.gov (United States)

    Fox, Brent I; Felkey, Bill G

    2015-03-01

    In our earliest thoughts of how to engage patients in self-care management, we found online banking and finance to be the best model for health care to follow. This model is still right for today. Although no digital approach will apply to 100% of any population, there is evidence that older patient populations see the benefit of being able to access their health care providers online and on mobile devices. It's all about the data, the systems, and the people.

  12. slide positivity rate of malaria among patients attending two ...

    African Journals Online (AJOL)

    DR. AMINU

    Key words: malaria, slide positivity rate, Kano metropolis. INTRODUCTION. Malaria has a worldwide distribution, affecting people of all ages, with an enormous burden amounting to. 300-500 million clinical cases per year, 80% of which occur in Africa (Lucas & Gills, 2003). Globally ten (10) new cases of malaria occur every ...

  13. Osteoporosis management in patients with breast cancer : EMAS position statement

    NARCIS (Netherlands)

    Trémollieres, Florence A; Ceausu, Iuliana; Depypere, Herman; Lambrinoudaki, Irene; Mueck, Alfred; Pérez-López, Faustino R; van der Schouw, Yvonne T; Senturk, Levent M; Simoncini, Tommaso; Stevenson, John C; Stute, Petra; Rees, Margaret

    Aromatase inhibitors (AIs) are the first-line recommended standard of care for postmenopausal estrogen receptor-positive breast cancer. Because they cause a profound suppression of estrogen levels, concerns regarding their potential to increase the risk of fracture were rapidly raised. There is

  14. Lack of immunomodulating effect of disulfiram on HIV positive patients

    DEFF Research Database (Denmark)

    Hørding, M; Gøtzsche, P C; Bygbjerg, Ib Christian

    1990-01-01

    Disulfiram (Antabuse (R)) is metabolized to two molecules of diethyldithiocarbamate, which has been reported to be an immunomodulating agent. In a double blind trial, 15 HIV antibody positive homosexual men were given daily doses of 100 mg or 400 mg of disulfiram or placebo, for 4 weeks. All had...

  15. Comparison between Human Immunodeficiency Virus Positive and Negative Patients with Tuberculosis in Southern Brazil

    Directory of Open Access Journals (Sweden)

    Lucélia Henn

    1999-05-01

    Full Text Available The objective of this study is to determine the different characteristics of human immunodeficiency virus (HIV positive and negative patients treated for tuberculosis (TBC in a tertiary hospital in Southern Brazil. We conducted a retrospective cohort study over a 5-year period, from January 1992 through December 1996. We reviewed medical charts of patients from our institution who received TBC treatment. We reviewed 167 medical charts of patients with confirmed TBC. HIV positivity was detected in 74 patients. There were statistically significant difference between HIV positive and negative patients in sex and age. HIV-infected patients showed significantly more signs of bacteremia than HIV-negative patients. Extra-pulmonary TBC was present respectively in 13 (17.6% and 21 (22.6% HIV positive and negative patients. There was a significant difference between chest radiograph presentation in HIV positive and negative patients. There were significantly lower hematocrit, hemoglobin, leukocyte and lymphocyte levels in HIV-positive compared to HIV-negative patients. Outcome was significantly different in the two groups with a death rate of 36.5% and 10.8% in HIV-positive and in HIV-negative patients. The difference between HIV positive and negative patients may have importance in the diagnosis, management and prognosis of patients with TBC.

  16. Field error lottery

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, C.J.; McVey, B. (Los Alamos National Lab., NM (USA)); Quimby, D.C. (Spectra Technology, Inc., Bellevue, WA (USA))

    1990-01-01

    The level of field errors in an FEL is an important determinant of its performance. We have computed 3D performance of a large laser subsystem subjected to field errors of various types. These calculations have been guided by simple models such as SWOOP. The technique of choice is utilization of the FELEX free electron laser code that now possesses extensive engineering capabilities. Modeling includes the ability to establish tolerances of various types: fast and slow scale field bowing, field error level, beam position monitor error level, gap errors, defocusing errors, energy slew, displacement and pointing errors. Many effects of these errors on relative gain and relative power extraction are displayed and are the essential elements of determining an error budget. The random errors also depend on the particular random number seed used in the calculation. The simultaneous display of the performance versus error level of cases with multiple seeds illustrates the variations attributable to stochasticity of this model. All these errors are evaluated numerically for comprehensive engineering of the system. In particular, gap errors are found to place requirements beyond mechanical tolerances of {plus minus}25{mu}m, and amelioration of these may occur by a procedure utilizing direct measurement of the magnetic fields at assembly time. 4 refs., 12 figs.

  17. Patient position alters attenuation effects in multipinhole cardiac SPECT

    International Nuclear Information System (INIS)

    Timmins, Rachel; Ruddy, Terrence D.; Wells, R. Glenn

    2015-01-01

    Purpose: Dedicated cardiac cameras offer improved sensitivity over conventional SPECT cameras. Sensitivity gains are obtained by large numbers of detectors and novel collimator arrangements such as an array of multiple pinholes that focus on the heart. Pinholes lead to variable amounts of attenuation as a source is moved within the camera field of view. This study evaluated the effects of this variable attenuation on myocardial SPECT images. Methods: Computer simulations were performed for a set of nine point sources distributed in the left ventricular wall (LV). Sources were placed at the location of the heart in both an anthropomorphic and a water-cylinder computer phantom. Sources were translated in x, y, and z by up to 5 cm from the center. Projections were simulated with and without attenuation and the changes in attenuation were compared. A LV with an inferior wall defect was also simulated in both phantoms over the same range of positions. Real camera data were acquired on a Discovery NM530c camera (GE Healthcare, Haifa, Israel) for five min in list-mode using an anthropomorphic phantom (DataSpectrum, Durham, NC) with 100 MBq of Tc-99m in the LV. Images were taken over the same range of positions as the simulations and were compared based on the summed perfusion score (SPS), defect width, and apparent defect uptake for each position. Results: Point sources in the water phantom showed absolute changes in attenuation of ≤8% over the range of positions and relative changes of ≤5% compared to the apex. In the anthropomorphic computer simulations, absolute change increased to 20%. The changes in relative attenuation caused a change in SPS of <1.5 for the water phantom but up to 4.2 in the anthropomorphic phantom. Changes were larger for axial than for transverse translations. These results were supported by SPS changes of up to six seen in the physical anthropomorphic phantom for axial translations. Defect width was also seen to significantly increase. The

  18. Creativity with dementia patients. Can creativity and art stimulate dementia patients positively?

    Science.gov (United States)

    Hannemann, Beat Ted

    2006-01-01

    Creative activities could be stimulating for dementia patients. This article gives a review of practical forms of treating dementia patients with art therapeutic indications. It is also a ground for long-term research objective: in brief, I take exception to such a view, contrary to the common belief in the society and some professionals in the healthcare of dementia patients, on the ground that the patients do not have the capacity to improve their own creativity. The theory of cognition tells us about the principle of being creative as a basis for human life. This specific principle is effective for the aged as well. In the long-term, the creative potential of old patients will be unblocked in individual and group therapy sessions. Creative activity has been shown to reduce depression and isolation, offering the power of choice and decisions. Towards the end of life, art and creativity offer a path of opening up the windows to people's emotional interiors. Creative- and art therapy provides possibilities that are mostly indicated to sharpen the capacity of the senses and the patients' propensity to act themselves. Nonverbal therapy methods, such as painting, music, etc., are able to influence the well-being of the patients positively, within the modern healthcare system in nursing homes. The elderly and some of the dementia patients take the initiative to combine creativity and arts and to define his/her feeling for aesthetical matters. Furthermore, group therapy sessions help against isolation and lack of life perspective and hope. Copyright 2006 S. Karger AG, Basel.

  19. Positioning accuracy for lung stereotactic body radiotherapy patients determined by on-treatment cone-beam CT imaging

    Science.gov (United States)

    Richmond, N D; Pilling, K E; Peedell, C; Shakespeare, D; Walker, C P

    2012-01-01

    Stereotactic body radiotherapy for early stage non-small cell lung cancer is an emerging treatment option in the UK. Since relatively few high-dose ablative fractions are delivered to a small target volume, the consequences of a geometric miss are potentially severe. This paper presents the results of treatment delivery set-up data collected using Elekta Synergy (Elekta, Crawley, UK) cone-beam CT imaging for 17 patients immobilised using the Bodyfix system (Medical Intelligence, Schwabmuenchen, Germany). Images were acquired on the linear accelerator at initial patient treatment set-up, following any position correction adjustments, and post-treatment. These were matched to the localisation CT scan using the Elekta XVI software. In total, 71 fractions were analysed for patient set-up errors. The mean vector error at initial set-up was calculated as 5.3±2.7 mm, which was significantly reduced to 1.4±0.7 mm following image guided correction. Post-treatment the corresponding value was 2.1±1.2 mm. The use of the Bodyfix abdominal compression plate on 5 patients to reduce the range of tumour excursion during respiration produced mean longitudinal set-up corrections of −4.4±4.5 mm compared with −0.7±2.6 mm without compression for the remaining 12 patients. The use of abdominal compression led to a greater variation in set-up errors and a shift in the mean value. PMID:22665927

  20. [Nasal leishmaniasis in an HIV-positive patient].

    Science.gov (United States)

    Grasa, J M; Lorente, J; Crego, F; Naches, S; Subirana, F X; Calderón, J R; Pollán, C; Encarnación, L F; Quesada, P

    2000-03-01

    Leishmania is currently one of the most clinically important protozoa in otorhinolaryngology. Mediterranean countries, including Spain, have endemic HIV and L. infantum. Dogs are the most important Leishmania reservoir. Leishmaniasis is transmitted basically by the bite of infected female Phlebotomus sandflies. Its clinical development depends mainly on the host's cellular immunity (TCD4+ lymphocyte count). About 400 cases of HIV-visceral leishmaniasis have been reported in Spain. However, exclusively cutaneous presentation of HIV-leishmaniasis coinfection has been observed in only 2-3% of cases. We report the case of a female HIV+ patient who developed cutaneous leishmaniasis of the nasal vestibule by L. infantum. The patient was treated satisfactorily with a combination of parenteral Pentostam (sodium stilbogluconate) and periodic intralesional injections of Pentostam. The patient was included in a secondary prophylaxis protocol for visceral leishmaniasis with a monthly dose of Glucantime (meglumine antimoniate) for life.

  1. Strategies to increase patient safety in haemodialysis: Application of the modal analysis system of errors and effects (FEMA system

    Directory of Open Access Journals (Sweden)

    María Dolores Arenas Jiménez

    2017-11-01

    Full Text Available Background: Haemodialysis (HD patients are a high-risk population group. For these patients, an error could have catastrophic consequences. Therefore, system that ensures the safety of these patients in an environment with high technology and great interaction of the human factor is a requirement. Objectives: To show a systematic working approach, reproducible in any HD unit, which consists of recording the complications and errors that occurred during the HD session; defining which of those complications could be considered adverse event (AE, and therefore preventable; and carrying out a systematic analysis of them, as well as of underlying real or potential errors, evaluating their severity, frequency and detection; as well as establishing priorities for action (Failure Mode and Effects Analysis system [FMEA systems]. Methods: Retrospective analysis of the graphs of all HD sessions performed during one month (October 2015 on 97 patients, analysing all recorded complications. The consideration of these complications as AEs was based on a consensus among 13 health professionals and 2 patients. The severity, frequency and detection of each AE were evaluated by the FMEA system. Results: We analysed 1303 HD treatments in 97 patients. A total of 383 complications (1 every 3.4 HD treatments were recorded. Approximately 87.9% of them were deemed AEs and 23.7% complications related with patients’ underlying pathology. There was one AE every 3.8 HD treatments. Hypertension and hypotension were the most frequent AEs (42.7 and 27.5% of all AEs recorded, respectively. Vascular-access related AEs were one every 68.5 HD treatments. A total of 21 errors (1 every 62 HD treatments, mainly related to the HD technique and to the administration of prescribed medication, were registered. The highest risk priority number, according to the FMEA, corresponded to errors related to patient body weight; dysfunction/rupture of the catheter; and needle extravasation

  2. Filaggrin compound heterozygous patients carry mutations in trans position

    DEFF Research Database (Denmark)

    Carlsen, Berit C; Meldgaard, Michael; Johansen, Jeanne D

    2013-01-01

    by means of allele-specific PCR amplification and analysis of PCR products by agarose gel electrophoresis. All R501X/2282del4 compound heterozygous samples collected over a 4-year period of routine FLG mutation testing were investigated. In total, 37 samples were tested. All thirty-seven R501X/2282del4......More than 40 null mutations in the filaggrin (FLG) gene are described. It is therefore possible to find two different null mutations in one individual (compound heterozygosity). It has been generally perceived that homozygous and compound heterozygous individuals were genotypically comparable......; however, this has not been scientifically investigated. Two different FLG null mutations in the same individual may be in trans position, meaning that each mutation locates to a different allele functionally equivalent to homozygosity, or may be in cis position, meaning that both mutations locate...

  3. How patient positioning affects radiographic signs of canine lung disease

    International Nuclear Information System (INIS)

    Steyn, P.F.; Green, R.W.

    1990-01-01

    A single radiographic projection risks missing signs of lung disease. Four case reports of dogs are given to emphasize inadequate visualization with just one or two radiographs. It is advisable to take both right and left lateral views along with a dorsoventral view in a patient, that might have lung disease

  4. Testicular tuberculosis in an HIV positive patient mimicking ...

    African Journals Online (AJOL)

    B.A. Ojo

    Abstract. With the upsurge of tuberculosis infection compounded by the pandemic Human Immune Deficiency Virus. (HIV), isolated testicular tuberculosis though a rarity, should be a differential diagnosis especially in the atypical age group of patients presenting with testicular swelling and in areas with high prevalence rate ...

  5. immunological profiles in hiv positive patients following haart

    African Journals Online (AJOL)

    2014-08-01

    Aug 1, 2014 ... undetectable viraemia); a recovery of CD4+ cells, a decrease in IL-10 (though it remained high for many patients ... A successful HAART results in CD4+ cells recovery, drop in viraemia and IL-10 with up-regulation of Th1 ... necrosis factor family (can induce cell death among other many functions, or ...

  6. cryptococcus meningitis in a cohort of hiv positive kenyan patients

    African Journals Online (AJOL)

    the acquired immunodeficiency syndrome. N. Engl. J. Med. 1997; 337:15-21. 7. Khanna N., Chandramuki A., Desai A., et al. Cryptococcol infections of the central nervous system: An analysis of predisposing factors, laboratory findings and outcome in patients from South India with special reference to HIV infection. J. Med.

  7. Two sides of the safety coin?: How patient engagement and safety climate jointly affect error occurrence in hospital units.

    Science.gov (United States)

    Schiffinger, Michael; Latzke, Markus; Steyrer, Johannes

    2016-01-01

    Safety climate (SC) and more recently patient engagement (PE) have been identified as potential determinants of patient safety, but conceptual and empirical studies combining both are lacking. On the basis of extant theories and concepts in safety research, this study investigates the effect of PE in conjunction with SC on perceived error occurrence (pEO) in hospitals, controlling for various staff-, patient-, and hospital-related variables as well as the amount of stress and (lack of) organizational support experienced by staff. Besides the main effects of PE and SC on error occurrence, their interaction is examined, too. In 66 hospital units, 4,345 patients assessed the degree of PE, and 811 staff assessed SC and pEO. PE was measured with a new instrument, capturing its core elements according to a recent literature review: Information Provision (both active and passive) and Activation and Collaboration. SC and pEO were measured with validated German-language questionnaires. Besides standard regression and correlational analyses, partial least squares analysis was employed to model the main and interaction effects of PE and SC on pEO, also controlling for stress and (lack of) support perceived by staff, various staff and patient attributes, and potential single-source bias. Both PE and SC are associated with lower pEO, to a similar extent. The joint effect of these predictors suggests a substitution rather than mutually reinforcing interaction. Accounting for control variables and/or potential single-source bias slightly attenuates some effects without altering the results. Ignoring PE potentially amounts to forgoing a potential source of additional safety. On the other hand, despite the abovementioned substitution effect and conjectures of SC being inert, PE should not be considered as a replacement for SC.

  8. Application of Barcoding to Reduce Error of Patient Identification and to Increase Patient's Information Confidentiality of Test Tube Labelling in a Psychiatric Teaching Hospital.

    Science.gov (United States)

    Liu, Hsiu-Chu; Li, Hsing; Chang, Hsin-Fei; Lu, Mei-Rou; Chen, Feng-Chuan

    2015-01-01

    Learning from the experience of another medical center in Taiwan, Kaohsiung Municipal Kai-Suan Psychiatric Hospital has changed the nursing informatics system step by step in the past year and a half . We considered ethics in the original idea of implementing barcodes on the test tube labels to process the identification of the psychiatric patients. The main aims of this project are to maintain the confidential information and to transport the sample effectively. The primary nurses had been using different work sheets for this project to ensure the acceptance of the new barcode system. In the past two years the errors in the blood testing process were as high as 11,000 in 14,000 events per year, resulting in wastage of resources. The actions taken by the nurses and the new barcode system implementation can improve the clinical nursing care quality, safety of the patients, and efficiency, while decreasing the cost due to the human error.

  9. Effect of Positive Psychotherapy in Depression Symptoms and Character Strengths in Cancer Affected Patients

    Directory of Open Access Journals (Sweden)

    R Khodabakhash

    2015-05-01

    Full Text Available The purpose of this research was to study the effect of positive psychotherapy on depression symptoms and character strengths in cancer affected patients. Based on a quasi-experimental design by available sampling, 58 cancer patients were investigated. 30 patients were assigned in two groups: 15 patients in positive psychotherapy group (treatment and 15 patients as control group. In the present research, Oxford Happiness-Depression Questionnaire (OHDQ and Values In Action Inventory of Strengths (VIA-IS were used. The results showed that the positive psychotherapy was effective in reducing depression, increasing the character strengths and virtues, improving meaningful, pleasant and engaged life of cancer patients.

  10. Clinical characteristics of adult patients with inborn errors of metabolism in Spain: A review of 500 cases from university hospitals

    Directory of Open Access Journals (Sweden)

    J. Pérez-López

    2017-03-01

    Full Text Available Patients with inborn errors of metabolism (IEMs have become an emerging and challenging group in the adult healthcare system whose needs should be known in order to implement appropriate policies and to adapt adult clinical departments. We aimed to analyze the clinical characteristics of adult patients with IEMs who attend the most important Spanish hospitals caring for these conditions. A cohort study was conducted in 500 patients, categorized by metabolic subtype according to pathophysiological classification. The most prevalent group of IEMs was amino acid disorders, with 108 (21.6% patients diagnosed with phenylketonuria. Lysosomal storage disorders were the second group, in which 32 (6.4% and 25 (5% patients had Fabry disease and Gaucher disease respectively. The great clinical heterogeneity, the significant delay in diagnosis after symptom onset, the existence of some degree of physical dependence in a great number of patients, the need for a multidisciplinary and coordinated approach, and the lack of specific drug treatment are common features in this group of conditions.

  11. Initial clinical experience with infrared-reflecting skin markers in the positioning of patients treated by conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Soete, Guy; Steene, Jan van de; Verellen, Dirk; Vinh-Hung, Vincent; Berge, Dirk van den; Michielsen, Dirk; Keuppens, Frans; Roover, Patricia de; Storme, Guy

    2002-01-01

    Purpose: To evaluate an infrared (IR) marker-based positioning system in patients receiving conformal radiotherapy for prostate cancer. Methods and materials: During 553 treatments, the ability of the IR system to automatically position the isocenter was recorded. Setup errors were measured by means of orthogonal verification films and compared to conventional positioning (using skin drawings and lasers) in 184 treatments. Results: The standard deviation of anteroposterior (AP) and lateral setup errors was significantly reduced with IR marker positioning compared to conventional: 2 vs. 4.8 mm AP (p<0.01) and 1.6 vs. 3.5 mm laterally (p<0.01). Longitudinally, the difference was not significant (3.5 vs. 3.0 mm). Systematic errors were on the average smaller AP and laterally for the IR method: 4.1 vs. 7.8 mm AP (p=0.01) and 3.1 vs. 5.6 mm lateral (p=0.07). Longitudinally, the IR system resulted in somewhat larger systematic errors: 5.0 vs. 3.4 mm for conventional positioning (p=0.03). The use of an off-line correction protocol, based on the average deviation measured over the first four fractions, allowed virtual elimination of systematic errors. Inability of the IR system to correctly locate the markers, leading to an executional failure, occurred in 21% of 553 fractions. Conclusion: IR marker-assisted patient positioning significantly improves setup accuracy along the AP and lateral axes. Executional failures need to be reduced

  12. CLINICOPATHOLOGICAL FACTORS ASSOCIATED WITH POSITIVE PREOPERATIVE AXILLARY ULTRASOUND SCANNING IN BREAST CANCER PATIENTS

    Directory of Open Access Journals (Sweden)

    Lona Jalini

    2016-01-01

    Full Text Available Background: Axillary lymph node status is the most important breast cancer prognostic factor. Preoperative axillary ultrasound examination (PAUS is used to triage patients for sentinel lymph node biopsy (SLNB or axillary lymph node dissection (ALND. We assessed the detection rate of lymph node metastases by PAUS in a screening unit and evaluated associations between clinicopathological factors and PAUS positivity. Patients and Methods: This was a single-centre retrospective analysis of data extracted from a hospital breast cancer database and clinical records. Clinical, radiological, and pathological and prognostic indices were compared between PAUS-positive and PAUS-negative patients subsequently found to have lymph node metastases on histopathological analysis. Results: Two hundred and two patients were eligible for analysis. 50.5% of lymph node-positive patients were correctly identified as PAUS positive. Patients with PAUS-positive lymph nodes had less favorable disease characteristics, namely clinically palpable lymph nodes, higher Nottingham prognostic (NPI index, high lymph node burden according to the European Society of Medical Oncology (ESMO group classification, and larger, grade 3 tumors with lymphovascular invasion and extranodal spread. Moreover, PAUS-positive patients had more macrometastases and lymph node involvement than PAUS-negative patients. Conclusion: PAUS-positive patients and PAUS-negative (SLNB-positive patients have different clinicopathological characteristics. The presence of LVI, extranodal spread, grade 3 histology, or large tumors with poor prognostic indices in PAUS-negative patients should be regarded with caution and perhaps prompt second-look ultrasound examination.

  13. Medical Error and Moral Luck.

    Science.gov (United States)

    Hubbeling, Dieneke

    2016-09-01

    This paper addresses the concept of moral luck. Moral luck is discussed in the context of medical error, especially an error of omission that occurs frequently, but only rarely has adverse consequences. As an example, a failure to compare the label on a syringe with the drug chart results in the wrong medication being administered and the patient dies. However, this error may have previously occurred many times with no tragic consequences. Discussions on moral luck can highlight conflicting intuitions. Should perpetrators receive a harsher punishment because of an adverse outcome, or should they be dealt with in the same way as colleagues who have acted similarly, but with no adverse effects? An additional element to the discussion, specifically with medical errors, is that according to the evidence currently available, punishing individual practitioners does not seem to be effective in preventing future errors. The following discussion, using relevant philosophical and empirical evidence, posits a possible solution for the moral luck conundrum in the context of medical error: namely, making a distinction between the duty to make amends and assigning blame. Blame should be assigned on the basis of actual behavior, while the duty to make amends is dependent on the outcome.

  14. Selective screening of 650 high risk Iranian patients for detection of inborn error of metabolism

    Directory of Open Access Journals (Sweden)

    Narges Pishva

    2015-02-01

    Full Text Available Objective: Although metabolic diseases individually are rare ,but overall have an incidence of 1/2000 and can cause devastating and irreversible effect if not diagnosed early and treated promptly. selective screening is an acceptable method for detection of these multi presentation diseases.Method: using panel neonatal screening for detection of metabolic diseases in 650 high risk Iranian patients in Fars province. The following clinical features were used as inclusion criteria for investigation of the patients.Lethargy, poor feeding ,persistent vomiting, cholestasis, intractable seizure ,decreased level of consciousness ,persistent hypoglycemia, unexplained acid base disturbance and unexplained neonatal death.Result: Organic acidemia with 40 cases (42% was the most frequent disorder diagnosed in our high risk populations, followed by disorder of galactose metabolism(30%, 15 patient had classic galactosemia(GALT

  15. Selective screening of 650 high risk Iranian patients for detection of inborn error of metabolism

    Directory of Open Access Journals (Sweden)

    Narges Pishva

    2015-02-01

    Full Text Available Objective: Although metabolic diseases individually are rare ,but overall have an incidence of 1/2000 and can cause devastating and irreversible effect if not diagnosed early and treated promptly. selective screening is an acceptable method for detection of these multi presentation diseases. Method: using panel neonatal screening for detection of metabolic diseases in 650 high risk Iranian patients in Fars province. The following clinical features were used as inclusion criteria for investigation of the patients. Lethargy, poor feeding ,persistent vomiting, cholestasis, intractable seizure ,decreased level of consciousness ,persistent hypoglycemia, unexplained acid base disturbance and unexplained neonatal death. Result: Organic acidemia with 40 cases (42% was the most frequent disorder diagnosed in our high risk populations, followed by disorder of galactose metabolism(30%, 15 patient had classic galactosemia(GALT

  16. Medication errors: prescribing faults and prescription errors.

    Science.gov (United States)

    Velo, Giampaolo P; Minuz, Pietro

    2009-06-01

    1. Medication errors are common in general practice and in hospitals. Both errors in the act of writing (prescription errors) and prescribing faults due to erroneous medical decisions can result in harm to patients. 2. Any step in the prescribing process can generate errors. Slips, lapses, or mistakes are sources of errors, as in unintended omissions in the transcription of drugs. Faults in dose selection, omitted transcription, and poor handwriting are common. 3. Inadequate knowledge or competence and incomplete information about clinical characteristics and previous treatment of individual patients can result in prescribing faults, including the use of potentially inappropriate medications. 4. An unsafe working environment, complex or undefined procedures, and inadequate communication among health-care personnel, particularly between doctors and nurses, have been identified as important underlying factors that contribute to prescription errors and prescribing faults. 5. Active interventions aimed at reducing prescription errors and prescribing faults are strongly recommended. These should be focused on the education and training of prescribers and the use of on-line aids. The complexity of the prescribing procedure should be reduced by introducing automated systems or uniform prescribing charts, in order to avoid transcription and omission errors. Feedback control systems and immediate review of prescriptions, which can be performed with the assistance of a hospital pharmacist, are also helpful. Audits should be performed periodically.

  17. PATIENT SAFETY AND MEDICATION ERRORS IN THE PROVISION OF HEALTH CARE SERVICES-CHALLENGES FOR CONTEMPORARY PRACTICE

    Directory of Open Access Journals (Sweden)

    Tatjana Stojković

    2016-06-01

    Full Text Available Non-maleficence represents one of the basic ethical principles that health care providers should be guided by during service delivery. Establishment of patient safety is nowadays recognized as an issue of global concern in health care and a critical component of quality management. The aim of this paper is to provide a literature review of the patient safety and medication errors concept, with special attention given to defining the most significant terms, analyzing the causal factors and reviewing their classification. Raising awareness about the importance of patient safety has resulted in an increase in the number of medication error studies over the last decade. The traditional approach which makes health workers responsible for reduction of incidents is replaced by the modern concept which implies the involvement of all stakeholders at all levels of the system. In developed countries, the application of prospective risk management models for specific health care processes has already started. However, all these studies are mainly carried out at the secondary and tertiary levels of health care, while they are almost non-existent at the primary level. In the Republic of Serbia, a Rulebook on indicators of the quality of health care has been recently adopted, but a trend of significant lack of data regarding patient safety can be noticed due to inadequate reporting. It is necessary to continue with the homogenization of terminology and to increase the number of analyses of causal factors with the aim of prospective risk identification, particularly in developing countries such as the Republic of Serbia.

  18. Error Patterns

    NARCIS (Netherlands)

    Hoede, C.; Li, Z.

    2001-01-01

    In coding theory the problem of decoding focuses on error vectors. In the simplest situation code words are $(0,1)$-vectors, as are the received messages and the error vectors. Comparison of a received word with the code words yields a set of error vectors. In deciding on the original code word,

  19. A comparative study of set up variations and bowel volumes in supine versus prone positions of patients treated with external beam radiation for carcinoma rectum.

    Science.gov (United States)

    Rajeev, K R; Menon, Smrithy S; Beena, K; Holla, Raghavendra; Kumar, R Rajaneesh; Dinesh, M

    2014-01-01

    A prospective study was undertaken to evaluate the influence of patient positioning on the set up variations to determine the planning target volume (PTV) margins and to evaluate the clinical relevance volume assessment of the small bowel (SB) within the irradiated volume. During the period of months from December 2011 to April 2012, a computed tomography (CT) scan was done either in supine position or in prone position using a belly board (BB) for 20 consecutive patients. All the patients had histologically proven rectal cancer and received either post- or pre-operative pelvic irradiation. Using a three-dimensional planning system, the dose-volume histogram for SB was defined in each axial CT slice. Total dose was 46-50 Gy (2 Gy/fraction), delivered using the 4-field box technique. The set up variation of the study group was assessed from the data received from the electronic portal imaging device in the linear accelerator. The shift along X, Y, and Z directions were noted. Both systematic and random errors were calculated and using both these values the PTV margin was calculated. The systematic errors of patients treated in the supine position were 0.87 (X-mm), 0.66 (Y-mm), 1.6 (Z-mm) and in the prone position were 1.3 (X-mm), 0.59 (Y-mm), 1.17 (Z-mm). The random errors of patients treated in the supine positions were 1.81 (X-mm), 1.73 (Y-mm), 1.83 (Z-mm) and in prone position were 2.02 (X-mm), 1.21 (Y-mm), 3.05 (Z-mm). The calculated PTV margins in the supine position were 3.45 (X-mm), 2.87 (Y-mm), 5.31 (Z-mm) and in the prone position were 4.91 (X-mm), 2.32 (Y-mm), 5.08 (Z-mm). The mean volume of the peritoneal cavity was 648.65 cm 3 in the prone position and 1197.37 cm 3 in the supine position. The prone position using BB device was more effective in reducing irradiated SB volume in rectal cancer patients. There were no significant variations in the daily set up for patients treated in both supine and prone positions.

  20. Quality assurance patient positioning and immobilization techniques for radiotherapy

    International Nuclear Information System (INIS)

    Wadhawan, G.S.; Negi, P.S.; Anand, A.K.; Munjal, R.K.; Sinha, S.N.

    2007-01-01

    Over the last decade the ability to precisely deliver radiotherapy (RT) treatments has advanced dramatically. Imaging technology has evolved to facilitate better target delineation during treatment planning. Treatment delivery techniques have advanced to enable intensity modulated RT (IMRT) treatments that provide radiation doses, tightly conforming to the target volumes. These advancements have been driven by the dual goals of maximizing the radiation dose to the tumor volume while minimizing the radiation dose to the surrounding normal tissue. The ability to expand the use of these techniques to deliver higher doses in fewer fractions is now largely limited by changes in the tumor position from day to day and even during treatment and so the ability to precisely locate the tumor throughout the course of RT has become a topic of concern

  1. Management of oral lesions in HIV-positive patients.

    Science.gov (United States)

    Baccaglini, Lorena; Atkinson, Jane C; Patton, Lauren L; Glick, Michael; Ficarra, Giuseppe; Peterson, Douglas E

    2007-03-01

    HIV/AIDS is currently the leading cause of death in Africa and the fourth leading cause of death worldwide. This systematic review of the literature was conducted to evaluate the evidence for treatment of the most common oral lesions associated with HIV: oral candidiasis with or without oropharyngeal involvement (OPC), oral hairy leukoplakia (OHL), recurrent aphthous-like ulcerations (RAU), oral Kaposi's sarcoma (OKS), orolabial herpes simplex infection (HSV), oral herpes zoster infection (VZV), intraoral or perioral warts (HPV), and HIV-associated periodontal diseases. Treatment of HIV-associated salivary gland disease is addressed in a different section of this World Workshop. We found the largest body of evidence for treatment of OPC in HIV patients. Future trials will be needed to test drugs currently in development for treatment of Candida strains that are resistant to existing therapies. There were no double blind, placebo-controlled randomized clinical trials (RCT) for topical treatment of OHL, and only one RCT for systemic treatment of the lesion with desciclovir. Systemic thalidomide was the only drug tested in RCT for treatment or prevention of RAU. Only 1 double-blind RCT comparing vinblastine and sodium tetradecyl sulfate was identified for localized treatment of OKS. Three drugs (famciclovir, acyclovir, and valaciclovir) were shown to be effective in randomized, double-blind trials for treatment or suppression of mucocutaneous HSV lesions in HIV patients. In all 3 trials, the effects of these medications on orolabial HSV lesions were not reported separately. There were no double-blind, placebo-controlled RCT testing topical treatments for orolabial HSV lesions in HIV patients. No trials testing treatments of oral VZV were identified. There were no double-blind, placebo-controlled RCT for treatment of HIV-associated intraoral or perioral warts or periodontal diseases. In conclusion, there is a need for well-designed RCTs to assess the safety and

  2. Phenotyping for patient safety: algorithm development for electronic health record based automated adverse event and medical error detection in neonatal intensive care.

    Science.gov (United States)

    Li, Qi; Melton, Kristin; Lingren, Todd; Kirkendall, Eric S; Hall, Eric; Zhai, Haijun; Ni, Yizhao; Kaiser, Megan; Stoutenborough, Laura; Solti, Imre

    2014-01-01

    Although electronic health records (EHRs) have the potential to provide a foundation for quality and safety algorithms, few studies have measured their impact on automated adverse event (AE) and medical error (ME) detection within the neonatal intensive care unit (NICU) environment. This paper presents two phenotyping AE and ME detection algorithms (ie, IV infiltrations, narcotic medication oversedation and dosing errors) and describes manual annotation of airway management and medication/fluid AEs from NICU EHRs. From 753 NICU patient EHRs from 2011, we developed two automatic AE/ME detection algorithms, and manually annotated 11 classes of AEs in 3263 clinical notes. Performance of the automatic AE/ME detection algorithms was compared to trigger tool and voluntary incident reporting results. AEs in clinical notes were double annotated and consensus achieved under neonatologist supervision. Sensitivity, positive predictive value (PPV), and specificity are reported. Twelve severe IV infiltrates were detected. The algorithm identified one more infiltrate than the trigger tool and eight more than incident reporting. One narcotic oversedation was detected demonstrating 100% agreement with the trigger tool. Additionally, 17 narcotic medication MEs were detected, an increase of 16 cases over voluntary incident reporting. Automated AE/ME detection algorithms provide higher sensitivity and PPV than currently used trigger tools or voluntary incident-reporting systems, including identification of potential dosing and frequency errors that current methods are unequipped to detect. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Factors that enable nurse-patient communication in a family planning context: a positive deviance study.

    Science.gov (United States)

    Kim, Young Mi; Heerey, Michelle; Kols, Adrienne

    2008-10-01

    Family planning programmes in developing countries need a better understanding of nurse-patient communication in order to improve the quality of counselling. To identify factors in the clinic and in the community that enable nurses and patients to communicate effectively with one another. The study explored the personal experiences of nurses and patients who communicate especially effectively during family planning consultations (so-called "positive deviants"). Sixty-four randomly selected public clinics located in East Java, Indonesia. Seven positive deviant nurses and 32 positive deviant patients were identified from among 64 nurses and 768 patients who participated in an earlier patient coaching study. Flooding prevented 5 patients from participating in the study, reducing their number to 27. Investigators conducted: (1) a content analysis of qualitative data collected by structured in-depth interviews and focus-group discussions (FGDs) with positive deviant nurses and patients, and (2) analyses of variance (ANOVA) of quantitative data on clinic, nurse, and patient characteristics. Positive deviant nurses identified four factors, listed in rough order of importance, that helped them communicate effectively: independent study to strengthen their knowledge and skills; communication aids; feedback from colleagues; and motivation stemming from a desire to help people, patients' appreciation, husband's support, and increased income. Positive deviant patients identified five enabling factors: motivation due to their need for a service; confidence in their own communication skills; positive feedback from nurses; belief in patients' right and responsibility to communicate with nurses; and communication aids. Insights from positive deviant nurses and patients suggest that efforts to improve nurse-patient communication should go beyond conventional communication skills training. Managers should consider a mix of clinic-based interventions (such as peer feedback

  4. Applying the Toyota Production System: using a patient safety alert system to reduce error.

    Science.gov (United States)

    Furman, Cathie; Caplan, Robert

    2007-07-01

    In 2002, Virginia Mason Medical Center (VMMC) adapted the Toyota Production System, also known as lean manufacturing. To translate the techniques of zero defects and stopping the line into health care, the Patient Safety Alert (PSA) system requires any employee who encounters a situation that is likely to harm a patient to make an immediate report and to cease any activity that could cause further harm (stopping the line). IMPLEMENTING THE PSA SYSTEM--STOPPING THE LINE: If any VMMC employee's practice or conduct is deemed capable of causing harm to a patient, a PSA can cause that person to be stopped from working until the problem is resolved. A policy statement, senior executive commitment, dedicated resources, a 24-hour hotline, and communication were all key features of implementation. As of December 2006, 6,112 PSA reports were received: 20% from managers, 8% from physicians, 44% from nurses, and 23% from nonclinical support personnel, for example. The number of reports received per month increased from an average of 3 in 2002 to 285 in 2006. Most reports were processed within 24 hours and were resolved within 2 to 3 weeks. Implementing the PSA system has drastically increased the number of safety concerns that are resolved at VMMC, while drastically reducing the time it takes to resolve them. Transparent discussion and feedback have helped promote staff acceptance and participation.

  5. The Use of Industrial Robot Arms for High Precision Patient Positioning

    International Nuclear Information System (INIS)

    Katuin, J.E.; Schreuder, A.N.; Starks, W.M.; Doskow, J.

    2003-01-01

    The Indiana University Cyclotron Facility (IUCF) is in the process of designing and building the Midwest Proton Radiation Institute (MPRI) [1]. The design process includes the development of several patient treatment systems. This paper discusses the use of two such systems that provide for the high precision positioning of a patient. They are the Patient Positioner System and the X-ray system. The Patient Positioner System positions an immobilized patient on a support device to a treatment position based on a prescribed Treatment Plan. The X-ray system uses an industrial robot arm to position a Digital Radiography Panel to acquire an X-ray image to verify the location of the prescribed treatment volume in a patient by comparing the acquired images with reference images obtained from the patient's Treatment plan

  6. A patient with an inborn error of vitamin B12 metabolism (cblF) detected by newborn screening.

    Science.gov (United States)

    Armour, Christine M; Brebner, Alison; Watkins, David; Geraghty, Michael T; Chan, Alicia; Rosenblatt, David S

    2013-07-01

    A neonate, who was found to have an elevated C3/C2 ratio and minimally elevated propionylcarnitine on newborn screening, was subsequently identified as having the rare cblF inborn error of vitamin B12 (cobalamin) metabolism. This disorder is characterized by the retention of unmetabolized cobalamin in lysosomes such that it is not readily available for cellular metabolism. Although cultured fibroblasts from the patient did not show the expected functional abnormalities of the cobalamin-dependent enzymes, methylmalonyl-CoA mutase and methionine synthase, they did show reduced synthesis of the active cobalamin cofactors adenosylcobalamin and methylcobalamin. Mutation analysis of LMBRD1 established that the patient had the cblF disorder. Treatment was initiated promptly, and the patient showed a robust response to regular injections of cyanocobalamin, and she was later switched to hydroxocobalamin. Currently, at 3 years of age, the child is clinically well, with appropriate development. Adjusted newborn screening cutoffs in Ontario allowed detection of a deficiency that might not have otherwise been identified, allowing early treatment and perhaps preventing the adverse sequelae seen in some untreated patients.

  7. No unified reward prediction error in local field potentials from the human nucleus accumbens: evidence from epilepsy patients.

    Science.gov (United States)

    Stenner, Max-Philipp; Rutledge, Robb B; Zaehle, Tino; Schmitt, Friedhelm C; Kopitzki, Klaus; Kowski, Alexander B; Voges, Jürgen; Heinze, Hans-Jochen; Dolan, Raymond J

    2015-08-01

    Functional magnetic resonance imaging (fMRI), cyclic voltammetry, and single-unit electrophysiology studies suggest that signals measured in the nucleus accumbens (Nacc) during value-based decision making represent reward prediction errors (RPEs), the difference between actual and predicted rewards. Here, we studied the precise temporal and spectral pattern of reward-related signals in the human Nacc. We recorded local field potentials (LFPs) from the Nacc of six epilepsy patients during an economic decision-making task. On each trial, patients decided whether to accept or reject a gamble with equal probabilities of a monetary gain or loss. The behavior of four patients was consistent with choices being guided by value expectations. Expected value signals before outcome onset were observed in three of those patients, at varying latencies and with nonoverlapping spectral patterns. Signals after outcome onset were correlated with RPE regressors in all subjects. However, further analysis revealed that these signals were better explained as outcome valence rather than RPE signals, with gamble gains and losses differing in the power of beta oscillations and in evoked response amplitudes. Taken together, our results do not support the idea that postsynaptic potentials in the Nacc represent a RPE that unifies outcome magnitude and prior value expectation. We discuss the generalizability of our findings to healthy individuals and the relation of our results to measurements of RPE signals obtained from the Nacc with other methods. Copyright © 2015 the American Physiological Society.

  8. Three-dimensional accuracy and interfractional reproducibility of patient fixation and positioning using a stereotactic head mask system

    International Nuclear Information System (INIS)

    Karger, Christian P.; Jaekel, Oliver; Debus, Juergen; Kuhn, Sabine; Hartmann, Guenther H.

    2001-01-01

    Purpose: Conformal radiotherapy in the head and neck region requires precise and reproducible patient setup. The definition of safety margins around the clinical target volume has to take into account uncertainties of fixation and positioning. Data are presented to quantify the involved uncertainties for the system used. Methods and Materials: Interfractional reproducibility of fixation and positioning of a target point in the brain was evaluated by biplanar films. 118 film pairs obtained at 52 fractions in 4 patients were analyzed. The setup was verified at the actual treatment table position by diagnostic X-ray units aligned to the isocenter and by a stereotactic X-ray localization technique. The stereotactic coordinates of the treated isocenter, of fiducials on the mask, and of implanted internal markers within the patient were measured to determine systematic and random errors. The data are corrected for uncertainty of the localization method. Results: Displacements in target point positioning were 0.35±0.41 mm, 1.22±0.25 mm, and -0.74±0.32 mm in the x, y, and z direction, respectively. The reproducibility of the fixation of the patient's head within the mask was 0.48 mm (x), 0.67 mm (y), and 0.72 mm (z). Rotational uncertainties around an axis parallel to the x, y, and z axis were 0.72 deg., 0.43 deg., and 0.70 deg., respectively. A simulation, based on the acquired data, yields a typical radial overall uncertainty for positioning and fixation of 1.80±0.60 mm. Conclusions: The applied setup technique showed to be highly reproducible. The data suggest that for the applied technique, a safety margin between clinical and planning target volume of 1-2 mm along one axis is sufficient for a target at the base of skull

  9. Position and Orientation Tracking in a Ubiquitous Monitoring System for Parkinson Disease Patients With Freezing of Gait Symptom

    Science.gov (United States)

    Català, Andreu; Rodríguez Martín, Daniel; van der Aa, Nico; Chen, Wei; Rauterberg, Matthias

    2013-01-01

    Background Freezing of gait (FoG) is one of the most disturbing and least understood symptoms in Parkinson disease (PD). Although the majority of existing assistive systems assume accurate detections of FoG episodes, the detection itself is still an open problem. The specificity of FoG is its dependency on the context of a patient, such as the current location or activity. Knowing the patient's context might improve FoG detection. One of the main technical challenges that needs to be solved in order to start using contextual information for FoG detection is accurate estimation of the patient's position and orientation toward key elements of his or her indoor environment. Objective The objectives of this paper are to (1) present the concept of the monitoring system, based on wearable and ambient sensors, which is designed to detect FoG using the spatial context of the user, (2) establish a set of requirements for the application of position and orientation tracking in FoG detection, (3) evaluate the accuracy of the position estimation for the tracking system, and (4) evaluate two different methods for human orientation estimation. Methods We developed a prototype system to localize humans and track their orientation, as an important prerequisite for a context-based FoG monitoring system. To setup the system for experiments with real PD patients, the accuracy of the position and orientation tracking was assessed under laboratory conditions in 12 participants. To collect the data, the participants were asked to wear a smartphone, with and without known orientation around the waist, while walking over a predefined path in the marked area captured by two Kinect cameras with non-overlapping fields of view. Results We used the root mean square error (RMSE) as the main performance measure. The vision based position tracking algorithm achieved RMSE = 0.16 m in position estimation for upright standing people. The experimental results for the proposed human orientation

  10. Effects of treatment position and patient immobilization on the variability of patient motion in the treatment of prostate cancer patients

    International Nuclear Information System (INIS)

    Nguyen, A.; Washington, M.; Wyman, B.; Song, P.; Bauml, J.; Tobias, R.; Vaida, F.; Chen, G.; Vijayakumar, S.; Reese, Michael

    1995-01-01

    Purpose/Objective: As dose-escalation is being attempted in the treatment of prostate cancer, uncertainties in patient position due to day-to-day setup has become increasingly critical. We present results from an ongoing study of the variability of patient positioning in prone versus supine treatment positions, as well as with and without immobilization using an aquaplast cast. Materials and Methods: We compared the probability and the amount of day-to-day movement of patients with prostate cancer. Patients were divided into three groups: (a) those treated supine without immobilization, (b) those treated supine and immobilized with an aquaplast cast over the abdomen and pelvis, and (c) those treated prone and similarly immobilized in aquaplast. The three components of patient motion - cephalo-caudad, anterior-posterior, and lateral - were examined separately. Portal films, taken at least once a week during treatment, were compared to simulation films and appropriate changes were made on the next day before treatment. This film record was used in our retrospective analysis of patient motion. To study the probability of movement we carried out a Likelihood Ratio test (LR) on a sample of 43 patients (20, 15, and 8 in treatment positions (a), (b), and (c) respectively). To study the amount of movement, templates with outlines of bony landmarks were generated based on the simulation film and overlaid on the portal film to measure the displacement. Results: Our measurements are summarized in the table below, where the p values for the difference in probability of movement (leftmost three columns) comes from the LR test and the amount of movement (rightmost three columns) is expressed as an average accompanied by a root-mean-square, in millimeters. Conclusions: From the data so far analyzed, patients treated supine and immobilized in an aquaplast cast -- group (b) -- exhibit the lowest probability of cephalo-caudad and anterior-posterior movement. In addition, although

  11. Positive predictive value of infective endocarditis in the Danish National Patient Registry: a validation study.

    Science.gov (United States)

    Østergaard, Lauge; Adelborg, Kasper; Sundbøll, Jens; Pedersen, Lars; Loldrup Fosbøl, Emil; Schmidt, Morten

    2018-05-30

    The positive predictive value of an infective endocarditis diagnosis is approximately 80% in the Danish National Patient Registry. However, since infective endocarditis is a heterogeneous disease implying long-term intravenous treatment, we hypothesiszed that the positive predictive value varies by length of hospital stay. A total of 100 patients with first-time infective endocarditis in the Danish National Patient Registry were identified from January 2010 - December 2012 at the University hospital of Aarhus and regional hospitals of Herning and Randers. Medical records were reviewed. We calculated the positive predictive value according to admission length, and separately for patients with a cardiac implantable electronic device and a prosthetic heart valve using the Wilson score method. Among the 92 medical records available for review, the majority of the patients had admission length ⩾2 weeks. The positive predictive value increased with length of admission. In patients with admission length value was 65% while it was 90% for admission length ⩾2 weeks. The positive predictive value was 81% for patients with a cardiac implantable electronic device and 87% for patients with a prosthetic valve. The positive predictive value of the infective endocarditis diagnosis in the Danish National Patient Registry is high for patients with admission length ⩾2 weeks. Using this algorithm, the Danish National Patient Registry provides a valid source for identifying infective endocarditis for research.

  12. Non-invasive ventilation in HIV positive patients with sepsis and ...

    African Journals Online (AJOL)

    Method: We conducted an observational prospective cohort study for the NIV arm (in the first half of 2016) with a retrospective chart review for the controls that focused on HIV positive patients with sepsis and hypoxaemic respiratory failure. 77 consecutive HIV positive patients with sepsis and respiratory distress meeting the ...

  13. Intra-arterial blood pressure reading in intensive care unit patients in the lateral position

    NARCIS (Netherlands)

    Aries, M.J.H.; Aslan, A.; Elting, J.W.J.; Stewart, R.E.; Zijlstra, Jan G.; de Keyser, J.; Vroomen, P.C.A.J.

    Background. Routine lateral turning of patients has become an accepted standard of care to prevent complications of immobility. The haemodynamic and oxygenation effects for patients in both lateral positions (45 degrees) are still a matter of debate. We aimed to study the effect of these positions

  14. Variations of Blood Pressure in Stroke Unit Patients May Result from Alternating Body Positions

    NARCIS (Netherlands)

    Aries, M.J.H.; Elting, Jan Willem; Stewart, Roy E.; de Keyser, Jacques; Thien, Theo; Kremer, Berry P.; Vroomen, Patrick C. A. J.

    Background: Blood pressure (BP) is one of the major vital parameters monitored in the stroke unit. The accuracy of indirect BP measurement is strongly influenced by the position of both patient and arm during the measurement. Acute stroke patients are often nursed in lateral decubitus positions. The

  15. Errors in Neonatology

    OpenAIRE

    Antonio Boldrini; Rosa T. Scaramuzzo; Armando Cuttano

    2013-01-01

    Introduction: Danger and errors are inherent in human activities. In medical practice errors can lean to adverse events for patients. Mass media echo the whole scenario. Methods: We reviewed recent published papers in PubMed database to focus on the evidence and management of errors in medical practice in general and in Neonatology in particular. We compared the results of the literature with our specific experience in Nina Simulation Centre (Pisa, Italy). Results: In Neonatology the main err...

  16. Patient safety incident reports related to traditional Japanese Kampo medicines: medication errors and adverse drug events in a university hospital for a ten-year period.

    Science.gov (United States)

    Shimada, Yutaka; Fujimoto, Makoto; Nogami, Tatsuya; Watari, Hidetoshi; Kitahara, Hideyuki; Misawa, Hiroki; Kimbara, Yoshiyuki

    2017-12-21

    Kampo medicine is traditional Japanese medicine, which originated in ancient traditional Chinese medicine, but was introduced and developed uniquely in Japan. Today, Kampo medicines are integrated into the Japanese national health care system. Incident reporting systems are currently being widely used to collect information about patient safety incidents that occur in hospitals. However, no investigations have been conducted regarding patient safety incident reports related to Kampo medicines. The aim of this study was to survey and analyse incident reports related to Kampo medicines in a Japanese university hospital to improve future patient safety. We selected incident reports related to Kampo medicines filed in Toyama University Hospital from May 2007 to April 2017, and investigated them in terms of medication errors and adverse drug events. Out of 21,324 total incident reports filed in the 10-year survey period, we discovered 108 Kampo medicine-related incident reports. However, five cases were redundantly reported; thus, the number of actual incidents was 103. Of those, 99 incidents were classified as medication errors (77 administration errors, 15 dispensing errors, and 7 prescribing errors), and four were adverse drug events, namely Kampo medicine-induced interstitial pneumonia. The Kampo medicine (crude drug) that was thought to induce interstitial pneumonia in all four cases was Scutellariae Radix, which is consistent with past reports. According to the incident severity classification system recommended by the National University Hospital Council of Japan, of the 99 medication errors, 10 incidents were classified as level 0 (an error occurred, but the patient was not affected) and 89 incidents were level 1 (an error occurred that affected the patient, but did not cause harm). Of the four adverse drug events, two incidents were classified as level 2 (patient was transiently harmed, but required no treatment), and two incidents were level 3b (patient was

  17. Fast time-of-flight camera based surface registration for radiotherapy patient positioning.

    Science.gov (United States)

    Placht, Simon; Stancanello, Joseph; Schaller, Christian; Balda, Michael; Angelopoulou, Elli

    2012-01-01

    This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. A novel preregistration algorithm, based on translation and rotation-invariant features representing surface structures, was developed. Using these features, corresponding three-dimensional points were computed in order to determine initial registration parameters. These parameters became a robust input to an accelerated version of the iterative closest point (ICP) algorithm for the fine-tuning of the registration result. Distance calibration and Kalman filtering were used to compensate for ToF-camera dependent noise. Additionally, the advantage of using the feature based preregistration over an "ICP only" strategy was evaluated, as well as the robustness of the rigid-transformation-based method to deformation. The proposed surface registration method was validated using phantom data. A mean target registration error (TRE) for translations and rotations of 1.62 ± 1.08 mm and 0.07° ± 0.05°, respectively, was achieved. There was a temporal delay of about 65 ms in the registration output, which can be seen as negligible considering the dynamics of biological systems. Feature based preregistration allowed for accurate and robust registrations even at very large initial displacements. Deformations affected the accuracy of the results, necessitating particular care in cases of deformed surfaces. The proposed solution is able to solve surface registration problems with an accuracy suitable for radiotherapy cases where external surfaces offer primary or complementary information to patient positioning. The system shows promising dynamic properties for its use in gating/tracking applications. The overall system is competitive with commonly-used surface registration technologies. Its main benefit is the

  18. The effectiveness of inking needle core prostate biopsies for preventing patient specimen identification errors: a technique to address Joint Commission patient safety goals in specialty laboratories.

    Science.gov (United States)

    Raff, Lester J; Engel, George; Beck, Kenneth R; O'Brien, Andrea S; Bauer, Meagan E

    2009-02-01

    The elimination or reduction of medical errors has been a main focus of health care enterprises in the United States since the year 2000. Elimination of errors in patient and specimen identification is a key component of this focus and is the number one goal in the Joint Commission's 2008 National Patient Safety Goals Laboratory Services Program. To evaluate the effectiveness of using permanent inks to maintain specimen identity in sequentially submitted prostate needle biopsies. For a 12-month period, a grossing technician stained each prostate core with permanent ink developed for inking of pathology specimens. A different color was used for each patient, with all the prostate cores from all vials for a particular patient inked with the same color. Five colors were used sequentially: green, blue, yellow, orange, and black. The ink was diluted with distilled water to a consistency that allowed application of a thin, uniform coating of ink along the edges of the prostate core. The time req