WorldWideScience

Sample records for patch test reactions

  1. Erythema-index of clinical patch test reactions

    DEFF Research Database (Denmark)

    Jemec, G B; Johansen, J D

    1995-01-01

    that the method could be used for the grading of eczematous reactions in a clinical setting as well. OBJECTIVE: To assess the usefulness of the erythema index for the quantification of eczematous reactions using the Derma-Spectrometer (Cortex technology, Hadsund, Denmark) in a clinical setting. METHOD......: The erythema index of 56 patch test reactions ranging from +? to +++, was compared to regional controls and negative patch tests (189). The effects of intrumental application pressure was studied in 5 volunteers. Statistical analysis was carried out using Mann-Whitney and Jonckheere-Terpstra tests. RESULTS......: The erythema-index was significantly higher in all degrees of patch test reactions than in uninvolved regional skin or negative patch tests. It also showed a significant positive trend for higher values in +, ++ and +++ reactions (P

  2. Relevance of positive patch-test reactions to fragrance mix.

    Science.gov (United States)

    Devos, Steven A; Constandt, Lieve; Tupker, Ron A; Noz, Kathy C; Lucker, Georges P H; Bruynzeel, Derk P; Schuttelaar, Marie-Louise A; Kruyswijk, Mente R J; van Zuuren, Esther J; Vink, Jaqueline; Coenraads, Pieter-Jan; Kiemeney, Lambertus A L M; van der Valk, Pieter G M

    2008-01-01

    Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong reactions. To improve the appraisal of FM patch-test reactions, we studied the relevance of reactions of different strength. We also studied the predictive value of the following on the relevance of the initial FM patch-test results: patch-test results of a repeated FM test; results of patch tests with balsam of Peru, colophony, and ingredients of the mix; and (history of) atopic dermatitis. One hundred thirty-eight patients who had doubtful positive (?+) or positive (+ to +++) reactions were included in the study. We determined relevance by history taking, location and course of the dermatitis, and additional patch testing. Patients were retested with FM and with each ingredient separately. The relevance of reactions to FM increases with the strength of the reactions. Predictors of relevance are the results of retesting with FM, the results of tests with the ingredients, and a history and/or present symptoms of atopic dermatitis. Retesting with FM and its ingredients may add to the benefit of patch testing.

  3. Histological distinction between early allergic and irritant patch test reactions

    DEFF Research Database (Denmark)

    Vestergaard, L; Clemmensen, Ole; Sørensen, Flemming Brandt

    1999-01-01

    Comparative light microscopic studies have revealed subtle differences between allergic and irritant reactions in the skin. In the search for specific differences, we focussed on the early inflammatory response. This pilot study was conducted to test the hypothesis that follicular spongiosis can...... differentiate between early allergic and irritant patch test reactions. 8 patients with known contact allergy to either colophony or quarternium-15 participated in the study. In each patient, allergic and irritant patch tests reactions were elicited, and 4-mm punch biopsies were taken after 6 8 h from...... clinically equipotent reactions. Paired sets of slides were assessed blindly by 2 pathologists. 1 patient showing a pityrosporum folliculitis was excluded from the study. All biopsies from allergic patch tests were characterized by follicular spongiosis, while biopsies from irritant patch tests showed...

  4. Limonene hydroperoxide analogues show specific patch test reactions.

    Science.gov (United States)

    Christensson, Johanna Bråred; Hellsén, Staffan; Börje, Anna; Karlberg, Ann-Therese

    2014-05-01

    The fragrance terpene R-limonene is a very weak sensitizer, but forms allergenic oxidation products upon contact with air. The primary oxidation products of oxidized limonene, the hydroperoxides, have an important impact on the sensitizing potency of the oxidation mixture. One analogue, limonene-1-hydroperoxide, was experimentally shown to be a significantly more potent sensitizer than limonene-2-hydroperoxide in the local lymph node assay with non-pooled lymph nodes. To investigate the pattern of reactivity among consecutive dermatitis patients to two structurally closely related limonene hydroperoxides, limonene-1-hydroperoxide and limonene-2-hydroperoxide. Limonene-1-hydroperoxide, limonene-2-hydroperoxide, at 0.5% in petrolatum, and oxidized limonene 3.0% pet. were tested in 763 consecutive dermatitis patients. Of the tested materials, limonene-1-hydroperoxide gave most reactions, with 2.4% of the patients showing positive patch test reactions. Limonene-2-hydroperoxide and oxidized R-limonene gave 1.7% and 1.2% positive patch test reactions, respectively. Concomitant positive patch test reactions to other fragrance markers in the baseline series were frequently noted. The results are in accordance with the experimental studies, as limonene-1-hydroperoxide gave more positive patch test reactions in the tested patients than limonene-2-hydroperoxide. Furthermore, the results support the specificity of the allergenic activity of the limonene hydroperoxide analogues and the importance of oxidized limonene as a cause of contact allergy. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Patch testing in non-immediate cutaneous adverse drug reactions: value of extemporaneous patch tests.

    Science.gov (United States)

    Assier, Haudrey; Valeyrie-Allanore, Laurence; Gener, Gwendeline; Verlinde Carvalh, Muriel; Chosidow, Olivier; Wolkenstein, Pierre

    2017-11-01

    Patch testing following a standardized protocol is reliable for identifying the culprit drug in cutaneous adverse drug reactions (CADRs). However, these patch tests (PTs) require pharmaceutical material and staff, which are not always easily available. To evaluate an extemporaneous PT method in CADRs. We retrospectively analysed data for all patients referred to our department between March 2009 and June 2013 for patch testing after a non-immediate CADR. The patients who supplied their own suspected drugs were tested both with extemporaneous PTs and with conventional PTs. Extemporaneous PTs involved a nurse crushing and diluting the drug in pet. in a ratio of approximately one-third to two-thirds. Standardized PTs were performed according to guidelines, with commercial drugs diluted to 30% or with active ingredients diluted to 10%. We analysed the data for the two PT methods in terms of the number of positive test reactions, drugs tested, and type of CADR for patients in whom the two PT methods were used. In total, 75 of 156 patients underwent the two PT procedures, including 91 double tests. Overall, 21 tests gave positive reactions with the two methods, and 69 other tests gave negative results with the two methods. Our series yielded results similar to those of published series concerning the types of CADR and the drugs responsible. Our results suggest that, for CADRs, if a patient supplies a suspected drug but if the pharmaceutical material and staff are not available for conventional PTs, extemporaneous PTs performed by the nurse with the commercial drug used by the patient can be useful and reliable. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Positive patch test reactions to oxidized limonene

    DEFF Research Database (Denmark)

    Bråred Christensson, Johanna; Andersen, Klaus E; Bruze, Magnus

    2014-01-01

    to oxidized R-limonene. OBJECTIVE: To study the exposure to limonene among consecutive dermatitis patients reacting to oxidized R-limonene in an international setting, and to assess the relevance of the exposure for the patients' dermatitis. METHODS: Oxidized R-limonene 3.0% (containing limonene...... hydroperoxides at 0.33%) in petrolatum was tested in 2900 consecutive dermatitis patients in Australia, Denmark, the United Kingdom, Singapore, Spain, and Sweden. A questionnaire assessing exposure to limonene-containing products was completed. RESULTS: Overall, exposure to products containing limonene was found...

  7. Histological distinction between early allergic and irritant patch test reactions

    DEFF Research Database (Denmark)

    Vestergaard, L; Clemmensen, Ole; Sørensen, Flemming Brandt

    1999-01-01

    no recognizable changes except a slight follicular spongiosis in 1 patient. The 2 pathologists agreed independently on the correct classification in 6 out of 7 cases (p=0.0156). We tested an optimized model, selecting non-irritant allergens and a well-known irritant. Further investigations are needed to elucidate......Comparative light microscopic studies have revealed subtle differences between allergic and irritant reactions in the skin. In the search for specific differences, we focussed on the early inflammatory response. This pilot study was conducted to test the hypothesis that follicular spongiosis can...... differentiate between early allergic and irritant patch test reactions. 8 patients with known contact allergy to either colophony or quarternium-15 participated in the study. In each patient, allergic and irritant patch tests reactions were elicited, and 4-mm punch biopsies were taken after 6 8 h from...

  8. Positive patch test reactions to oxidized limonene: exposure and relevance.

    Science.gov (United States)

    Bråred Christensson, Johanna; Andersen, Klaus E; Bruze, Magnus; Johansen, Jeanne D; Garcia-Bravo, Begoña; Gimenez Arnau, Ana; Goh, Chee-Leok; Nixon, Rosemary; White, Ian R

    2014-11-01

    R-Limonene is a common fragrance terpene found in domestic and industrial products. R-Limonene autoxidizes on air exposure, and the oxidation products can cause contact allergy. In a recent multicentre study, 5.2% (range 2.3-12.1%) of 2900 patients showed a positive patch test reaction to oxidized R-limonene. To study the exposure to limonene among consecutive dermatitis patients reacting to oxidized R-limonene in an international setting, and to assess the relevance of the exposure for the patients' dermatitis. Oxidized R-limonene 3.0% (containing limonene hydroperoxides at 0.33%) in petrolatum was tested in 2900 consecutive dermatitis patients in Australia, Denmark, the United Kingdom, Singapore, Spain, and Sweden. A questionnaire assessing exposure to limonene-containing products was completed. Overall, exposure to products containing limonene was found and assessed as being probably relevant for the patients' dermatitis in 36% of the limonene-allergic patients. In Barcelona and Copenhagen, > 70% of the patients were judged to have had an exposure to limonene assessed as relevant. Oxidized R-limonene is a common fragrance allergen, and limonene was frequently found in the labelling on the patients' products, and assessed as relevant for the patients' dermatitis. A large number of domestic and occupational sources for contact with R-limonene were identified. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Relationship between formaldehyde and quaternium-15 contact allergy. Influence of strength of patch test reactions

    NARCIS (Netherlands)

    de Groot, Anton C.; Blok, Janine; Coenraads, Pieter-Jan

    2010-01-01

    Objectives: To test our hypothesis that patients with stronger patch test reactions to formaldehyde are more likely to react to quaternium-15, attesting to the aetiological role for formaldehyde in such co-reactivity. Methods: Retrospective analysis of all patients patch tested with formaldehyde and

  10. Skin irritability to sodium lauryl sulfate is associated with increased positive patch test reactions.

    Science.gov (United States)

    Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W

    2014-07-01

    As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.

  11. Hypersensitivity reactions to metallic implants-diagnostic algorithm and suggested patch test series for clinical use

    DEFF Research Database (Denmark)

    Schalock, Peter C; Menné, Torkil; Johansen, Jeanne D

    2011-01-01

    algorithm to guide the selection of screening allergen series for patch testing is provided. At a minimum, an extended baseline screening series and metal screening is necessary. Static and dynamic orthopaedic implants, intravascular stent devices, implanted defibrillators and dental and gynaecological......Cutaneous and systemic hypersensitivity reactions to implanted metals are challenging to evaluate and treat. Although they are uncommon, they do exist, and require appropriate and complete evaluation. This review summarizes the evidence regarding evaluation tools, especially patch and lymphocyte...... transformation tests, for hypersensitivity reactions to implanted metal devices. Patch test evaluation is the gold standard for metal hypersensitivity, although the results may be subjective. Regarding pre-implant testing, those patients with a reported history of metal dermatitis should be evaluated by patch...

  12. Hypersensitivity reactions to metallic implants-diagnostic algorithm and suggested patch test series for clinical use

    DEFF Research Database (Denmark)

    Schalock, Peter C; Menné, Torkil; Johansen, Jeanne D

    2011-01-01

    Cutaneous and systemic hypersensitivity reactions to implanted metals are challenging to evaluate and treat. Although they are uncommon, they do exist, and require appropriate and complete evaluation. This review summarizes the evidence regarding evaluation tools, especially patch and lymphocyte...... transformation tests, for hypersensitivity reactions to implanted metal devices. Patch test evaluation is the gold standard for metal hypersensitivity, although the results may be subjective. Regarding pre-implant testing, those patients with a reported history of metal dermatitis should be evaluated by patch...... testing. Those without a history of dermatitis should not be tested unless considerable concern exists. Regarding post-implant testing, a subset of patients with metal hypersensitivity may develop cutaneous or systemic reactions to implanted metals following implant. For symptomatic patients, a diagnostic...

  13. Relevance of positive patch-test reactions to fragrance mix.

    NARCIS (Netherlands)

    Devos, S.A.; Constandt, L.; Tupker, R.A.; Noz, K.C.; Lucker, G.P.H.; Bruynzeel, D.P.; Schuttelaar, M.L.; Kruyswijk, M.R.; Zuuren, E.J. van; Vink, J.; Coenraads, P.J.; Kiemeney, L.A.L.M.; Valk, P.G.M. van der

    2008-01-01

    BACKGROUND: Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong

  14. Relevance of positive patch-test reactions to fragrance mix

    NARCIS (Netherlands)

    Devos, S.A.; Constandt, L.; Tupker, R.A.; Noz, K.C.; Lucker, G.P.H.; Bruynzeel, D.P.; Schuttelaar, M.L.A.; Kruyswijk, M.R.J.; van Zuuren, E.J.; Vink, J.; Coenraads, P.J.; Kiemeney, L.A.L.M.; van der Valk, P.G.M.

    2008-01-01

    BACKGROUND: Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong

  15. Evaluation of canine adverse food reactions by patch testing with single proteins, single carbohydrates and commercial foods.

    Science.gov (United States)

    Johansen, Cornelia; Mariani, Claire; Mueller, Ralf S

    2017-10-01

    Adverse food reaction (AFR) is an important differential diagnosis for the pruritic dog. It is usually diagnosed by feeding an elimination diet with a novel protein and carbohydrate source for eight weeks followed by subsequent food provocation. A previous study demonstrated that patch testing dogs with foods had a high sensitivity and negative predictability for selection of elimination diet ingredients. The aim of this study was to investigate patch testing with proteins, carbohydrates and dry commercial dog food in dogs to determine whether there was value in patch testing to aid the diagnosis of canine adverse food reaction. Twenty five privately owned dogs, with confirmed AFR, underwent provocation trials with selected food antigens and patch testing. For proteins, carbohydrates and dry dog food the sensitivity of patch testing was 100%, 70% and 22.2%, respectively; the negative predictive values of patch testing were 100%, 79% and 72%. The positive predictive values of patch testing for proteins and carbohydrates were 75% and 74%, respectively. This study confirmed that patch testing may be useful for the selection of a suitable protein source for an elimination diet in dogs with suspected AFR, but not as a diagnostic tool for canine AFR. Results for proteins are more reliable than for carbohydrates and the majority of positive patch test reactions were observed with raw protein. Patch testing with commercial dog food does not seem to be useful. © 2017 ESVD and ACVD.

  16. Biocide patch tests

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Veien, Niels

    1985-01-01

    Routine patch testing with a series of 6 industrial biocides containing methylene-bis-thiocyanate (Cytox 3522), benzisothiazolin-3-one (BIT), chlorocresol (Preventol CMK), 2-n-octyl-4-isothiazolin-3-one (Kathon 893), polyhydroxymethylene monobenzylether (Preventol D2) or 1,3,5-tris (hydroxy......-ethyl) hexahydrotriazine (Grotan BK) was carried out in 6 Danish out-patient clinics to evaluate guinea pig allergy test results with the same compounds. A total of 1652 consecutive patients with dermatitis were tested. The usefulness of this patch test battery was limited. There were a few positive reactions to Cytox...... of male patients and atopics, but significant differences in the frequencies of occupational cases, hand eczemas, and leg ulcers/stasis dermatitis, indicating possible variations in referral patterns, use of patch tests, and/or environmental factors....

  17. Stratum corneum profiles of inflammatory mediators in patch test reactions to common contact allergens and sodium lauryl sulfate.

    Science.gov (United States)

    Koppes, S A; Ljubojevic Hadzavdic, S; Jakasa, I; Franceschi, N; Jurakić Tončić, R; Marinović, B; Brans, R; Gibbs, S; Frings-Dresen, M H W; Rustemeyer, T; Kezic, S

    2017-06-01

    Recent studies have demonstrated allergen-specific differences in the gene expression of inflammatory mediators in patch tested skin. To determine levels of various inflammatory mediators in the stratum corneum (SC) after patch testing with common contact allergens and the skin irritant sodium lauryl sulfate (SLS). In total, 27 individuals who had previously patch tested positive to nickel, chromium, methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) or para-phenylenediamine were retested and then patch tested with SLS and petrolatum, with petrolatum serving as the patch test control. At 72 h, the test sites were clinically graded and the SC samples collected on adhesive tape. The levels of 18 of the 32 quantified mediators differed significantly from that of the control patches for at least one of the tested substances. SLS and MCI/MI induced the largest number of immunomediators. Interleukin (IL)-16 levels were significantly higher in patch test reactions in all allergens than they were in the controls, while no significant difference was detected for SLS. Furthermore, a strong negative correlation was found between strength of patch test reaction and IL-1α levels. Cytokine profiles in the SC of patch tested skin did not show a distinct allergen-specific pattern. However, MCI/MI induced a larger and wider immune response than the other allergens, perhaps due to its potency as an irritant. The levels of IL-16 were significantly increased in patch test reactions to allergens but not to SLS; thus, they may help clinicians to differentiate between allergic contact dermatitis and irritant contact dermatitis. © 2016 British Association of Dermatologists.

  18. A stronger patch test elicitation reaction to the allergen hydroxycitronellal plus the irritant sodium lauryl sulfate

    DEFF Research Database (Denmark)

    Heydorn, S; Andersen, K E; Johansen, J D

    2003-01-01

    Household and cleaning products often contain both allergens and irritants. The aim of this double-blinded, randomized, paired study was to determine whether patch testing with an allergen (hydroxycitronellal) combined with an irritant [sodium lauryl sulfate (SLS)] cause a stronger patch test...

  19. Patch photopatch test at Manipal

    Directory of Open Access Journals (Sweden)

    Panja Arindrajit

    1994-01-01

    Full Text Available Patch and photopatch testing was performed on 55 patients with history of photosensitivity using Scandanavian photo patch test antigens obtained from Chemotechnique Diagnostics AB Sweden. The commonest reactions were seen to perfume mix 4 (21.0%, PABA 3 (15.78%, promethazine hydrochloride 3 (15.78%, chlorpromazine hydrochloride 3 (15.78%, balsam of peru 2 (10.52%, usnic acid, hexachlorophane, musk ambrette and 6 methyl coumarin showed 1 positive reaction each (5.26% suggesting either phototoxicity or photo sensitization. Patch and photo patch test positive reaction suggesting allergic sensitisation was seen to balsam of peru 3 (23.0% perfume mix 3 (23.0% promethazine hydrochloride 2 (15.3% and PABA, 6 methyl coumarin, tribromosalicylanilide, atranorin and wood mix showed positive reaction in one case each (7.69%. We conclude that photoxic or photo allergic reaction is a problem in India and patch photo patch test should be performed in all cases of idiopathic light eruptions to rule out photo sensitisation and in cases where photo sensitivity of exogenous origin is suspected.

  20. Fragrance patch tests prepared in advance may give false-negative reactions.

    Science.gov (United States)

    Mowitz, Martin; Svedman, Cecilia; Zimerson, Erik; Bruze, Magnus

    2014-11-01

    Several of the ingredients in fragrance mix I (FM I) have been shown to evaporate from petrolatum preparations applied in test chambers to an extent that can be suspected to affect the patch test result. To compare the reactivity towards FM I and fragrance mix II (FM II) when they are applied in test chambers in advance and immediately prior to the patch test occasion. Seven hundred and ninety-five consecutive patients were simultaneously patch tested with duplicate samples of FM I and FM II. One sample was applied in the test chamber 6 days in advance (6D sample), and the other sample was applied immediately before the patients were patch tested (fresh sample). Twenty-two (2.8%) patients reacted exclusively to the fresh sample of FM I, 6 (0.7%) reacted exclusively to the 6D sample, and 22 (2.8%) reacted to both samples. The corresponding numbers for FM II were 9 (1.1%) for the fresh sample, 6 (0.7%) for the 6D sample and 12 (1.5%) for both samples. There was a statistically significant difference between the numbers of patients reacting to the fresh and 6D samples of FM I. No corresponding difference was observed for FM II. This can probably be explained by differences in volatilities between the ingredients of FM I and FM II. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Severe allergic reactions to para-phenylenediamine in children and adolescents: should the patch test concentration of PPD be changed?

    Science.gov (United States)

    Spornraft-Ragaller, Petra; Kämmerer, Eva; Gillitzer, Claus; Schmitt, Jochen

    2012-04-01

    Semipermanent henna tattoos containing para-phenylenediamine (PPD) are a well-known cause of severe contact dermatitis, mainly in children. Another relevant exposure source to PPD are hair dyes, which are increasingly used by children and have also been reported to cause intense facial and scalp dermatitis. German patch test guidelines for children recommend that PPD should only be tested in patients who have had a henna tattoo, and then at a reduced concentration of PPD 0.5 % for 24 hours. We report on patch test results in four patients, three children and one adolescent, with a history of contact dermatitis to henna tattoos or hair dye. We used the recommended or even lower patch test concentrations of PPD with 24-hours exposure in all patients. All patients showed very strong patch test reactions to PPD and cross-reactions to related compounds even after dilution of PPD to as low as 0.05 %. Therefore, we suggest that in children with a history of allergic reactions to this compound, a titration test should be performed beginning at a concentration of maximal 0.05 %. This procedure has also been proposed previously based on a larger cases series in adults. © The Authors • Journal compilation © Blackwell Verlag GmbH, Berlin.

  2. Patch test study of 90 patients with tattoo reactions: negative outcome of allergy patch test to baseline batteries and culprit inks suggests allergen(s) are generated in the skin through haptenization.

    Science.gov (United States)

    Serup, Jørgen; Hutton Carlsen, Katrina

    2014-11-01

    Tattoo reactions, especially in red tattoos, are often suggested as allergic in nature, however, systematic evaluation by patch testing has not performed in the past. To report the results of patch testing in 90 patients with non-infectious chronic tattoo reactions. From 2009 to 2013 at the 'Tattoo Clinic', Department of Dermatology, Bispebjerg University Hospital, 90 patients were patch tested with batteries of baseline allergens, disperse dyes/textile allergens, and a selection of tattoo ink stock products, which, according to case observations, were problematic, supplemented with individual culprit inks when accessible. Patients with reactions to the tattoo colour red, the most predominant colour associated with skin reactions, showed negative patch test results with common allergens. Outcomes were also negative in patients who had experienced concomitant reactions in another hitherto tolerated tattoo of the same colour as the problematic tattoo. The allergen or allergens responsible for tattoo reactions are not present directly in tattoo ink stock products. This is despite the fact that clinical histories suggest that the vast majority of clinical reactions, especially reactions to red and red nuances, are likely to be allergic events caused by the injected inks. We suggest that the responsible allergen results from a complicated and slow process of haptenization, which may even include photochemical cleavage of red azo pigment. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. [Patch testing: historical aspects].

    Science.gov (United States)

    Lachapelle, J-M

    2009-01-01

    This article reviews the key points in the history of patch testing, which spans more than a century, starting with the first description of the method by J. Jadassohn in 1895. Special attention is paid to the contribution of French schools in this field, which led to the foundation of the Groupe d'études et de recherches en dermato-allergologie (GERDA).

  4. Stratum corneum profiles of inflammatory mediators in patch test reactions to common contact allergens and sodium lauryl sulfate

    NARCIS (Netherlands)

    Koppes, S. A.; Ljubojevic Hadzavdic, S.; Jakasa, I.; Franceschi, N.; Jurakić Tončić, R.; Marinović, B.; Brans, R.; Gibbs, S.; Frings-Dresen, M. H. W.; Rustemeyer, T.; Kezic, S.

    2017-01-01

    Background Recent studies have demonstrated allergen-specific differences in the gene expression of inflammatory mediators in patch tested skin. Objectives To determine levels of various inflammatory mediators in the stratum corneum (SC) after patch testing with common contact allergens and the skin

  5. Contact allergic dermatitis from melamine formaldehyde resins in a patient with a negative patch-test reaction to formaldehyde.

    Science.gov (United States)

    García Gavin, Juan; Loureiro Martinez, Manuel; Fernandez-Redondo, Virginia; Seoane, Maria-José; Toribio, Jaime

    2008-01-01

    Melamine paper is a basic material used in the furniture industry for home and office interiors. Contact allergic dermatitis from melamine formaldehyde resins (MFRs) should be considered in patients who work on melamine paper impregnation lines. We report a case of a 28-year-old female plywood worker who developed eczema on the dorsal side of her hands and wrists after 2 years of working on the melamine paper impregnation line. She had a relevant positive patch-test reaction to MFR, with a negative reaction to formaldehyde. Contact dermatitis due to MFR is not common, and it is usually related to products that are not fully cured or to close contact with intermediate products on the assembly line. Formaldehyde release from MFR can explain most of the positive responses. To our knowledge, this is the first report of MFR contact allergic dermatitis in a worker on a melamine paper impregnation line.

  6. Patch Test Negative Generalized Dermatitis.

    Science.gov (United States)

    Spiker, Alison; Mowad, Christen

    2016-01-01

    Allergic contact dermatitis is a common condition in dermatology. Patch testing is the criterion standard for diagnosis. However, dermatitis is not always caused by an allergen, and patch testing does not identify a culprit in every patient. Generalized dermatitis, defined as eczematous dermatitis affecting greater than 3 body sites, is often encountered in dermatology practice, especially patch test referral centers. Management for patients with generalized dermatitis who are patch test negative is challenging. The purpose of this article is to outline an approach to this challenging scenario and summarize the paucity of existing literature on patch test negative generalized dermatitis.

  7. Topical non-peptide antagonists of sensory neurotransmitters substance P and CGRP do not modify patch test and prick test reactions

    DEFF Research Database (Denmark)

    Wallengren, Joanna; Edvinsson, Lars

    2014-01-01

    developed. Their effect on the skin barrier was measured in terms of transepidermal water loss (TEWL) while permeation was calculated using permeation coefficients. Patch tests in patients allergic to nickel and prick test reactions to histamine were used as models. None of the treatments increased TEWL......, suggesting there to be no impairment of the skin barrier. Permeation coefficients indicated moderate permeation. Histamine prick tests induced a flare with a mean area of 662 + 275 mm(2) and a weal with a mean volume of 49 + 11 mm(3). These reactions as well as histamine-induced pruritus were not affected...... significantly by any of the treatments. Treatment with aprepitant and its vehicle alone resulted in a potentiating of the infiltration of nickel reactions compared with test reactions obtained after no treatment (1147 + 423 mm(3) and 1427 + 566 mm(3) vs 683 +202 mm(3)) (p = 0.03). Telcagepant induced...

  8. Non-standard patch test

    Directory of Open Access Journals (Sweden)

    Astri Adelia

    2018-06-01

    Full Text Available In managing contact dermatitis, identification of the causative agent is essential to prevent recurrent complaints. Patch test is the gold standard to identify the causative agent. Nowadays, there are many patch test standard materials available in the market, but do not include all the materials that potentially cause contact dermatitis. Patch test using patient’s own products or later we refer to as non-standard materials, is very helpful in identifying the causative agents of contact dermatitis. Guidance is needed in producing non-standard patch test materials in order to avoid test results discrepancy.

  9. Patch test reactions associated with sunscreen products and the importance of testing to an expanded series: retrospective analysis of North American Contact Dermatitis Group data, 2001 to 2010.

    Science.gov (United States)

    Warshaw, Erin M; Wang, Michael Z; Maibach, Howard I; Belsito, Donald V; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Sasseville, Denis; Zirwas, Matthew J; Fowler, Joseph F; DeKoven, Joel G; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Storrs, Frances J

    2013-01-01

    Both active and inactive ingredients in sunscreen may cause contact dermatitis. This study aimed to describe allergens associated with a sunscreen source. A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 2001 and 2010 was performed. Of 23,908 patients patch tested, 219 (0.9%) had sunscreen coded as an allergen source. Patients who were male, with occupational dermatitis, or older (older than 40 years) had significantly lower rates of allergic reactions to sunscreens; the most commonly affected areas were the face and exposed sites (P Contact Dermatitis Group screening series of 65 to 70 allergens. A supplemental antigen series is important in detecting allergy to sunscreens.

  10. Patch testing and allergen-specific serum IgE and IgG antibodies in the diagnosis of canine adverse food reactions.

    Science.gov (United States)

    Bethlehem, Simone; Bexley, Jennifer; Mueller, Ralf S

    2012-02-15

    Adverse food reaction (AFR) is a common differential diagnosis for pruritic dogs. The only way to diagnose AFR is an elimination diet of 6-8 weeks with a protein and a carbohydrate source not previously fed. In humans, patch testing has been shown to be a useful tool to diagnose food allergies. In veterinary medicine, serum food allergen-specific antibody testing is widely offered to identify suitable ingredients for such diets. The aim of this study was to determine sensitivity, specificity, negative and positive predictability of patch testing with and serum antibody testing for a variety of common food stuffs. Twenty-five allergic dogs underwent an elimination diet and individual rechallenge with selected food stuffs, food patch testing and serum testing for food-antigen specific IgE and IgG. Eleven clinically normal control dogs only were subjected to patch and serum testing. The sensitivity and specificity of the patch test were 96.7 and 89.0% respectively, negative and positive predictability were 99.3 and 63.0%. For IgE and IgG the sensitivity was 6.7 and 26.7%, specificity were 91.4 and 88.3%, the negative predictive values 80.7 and 83.7% and the positive predictive values were 15.4 and 34.8%. Based on these results, a positive reaction of a dog on these tests is not very helpful, but a negative result indicates that this antigen is tolerated well. We conclude that patch testing (and to a lesser degree serum testing) can be helpful in choosing ingredients for an elimination diet in a dog with suspected AFR. Copyright © 2012. Published by Elsevier B.V.

  11. Flu Vaccine Skin Patch Tested

    Science.gov (United States)

    ... Subscribe September 2017 Print this issue Health Capsule Flu Vaccine Skin Patch Tested En español Send us ... Each year, millions of people nationwide catch the flu. The best way to protect yourself is to ...

  12. Dose-response testing with nickel sulphate using the TRUE test in nickel-sensitive individuals. Multiple nickel sulphate patch-test reactions do not cause an 'angry back'

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Lidén, C; Hansen, J

    1993-01-01

    The aim of this study was to employ the TRUE test assay to confirm the presence or absence of the 'angry back' phenomenon, i.e. that a strong positive patch-test reaction heightens adjacent patch-test response. In addition, we wished to establish the dose-response relationship for nickel sulphate...... back' phenomenon was not apparent in this study, as the spill-over effect was not statistically significant. Strong reactions to high concentrations of nickel sulphate did not enhance the response to adjacent lower concentrations of nickel sulphate....

  13. The MOAHLFA index of irritant sodium lauryl sulfate reactions: first results of a multicentre study on routine sodium lauryl sulfate patch testing.

    Science.gov (United States)

    Uter, Wolfgang; Geier, Johannes; Becker, Detlef; Brasch, Jochen; Löffler, Harald

    2004-01-01

    In a multicentre study of the German Contact Dermatitis Research Group, sodium lauryl sulfate (SLS) 0.25% and 0.5% aq. has been added to routine allergen patch tests to assess its properties as a convenient diagnostic indicator of individual susceptibility to irritation at the time of patch testing. Previous studies indicated that irritant SLS reactivity may be related to individual factors such as age and sex. As these factors are, in turn, among the important predictors of contact allergy to many allergens, e.g. summarized in the 'MOAHLFA index', the impact of the MOAHLFA factors on irritant SLS patch test reactivity, and thus a potential for confounding, was assessed in the 5971 participating patients. As a result of 2 logistic regression analyses with an irritant reaction to 0.25% and 0.5% SLS, respectively, as outcome, male sex was identified as a relatively weak but significant risk factor (OR 1.38), while age 40 years or older was an even weaker risk factor (OR 1.22 and 1.15, respectively). Upon detailed analysis, no clear age gradient could, however, be identified. 1-day exposure time almost halved the odds of an irritant SLS reaction. In conclusion, this type of SLS patch test can be regarded as robust, indicating individual irritability relatively independent from the individual factors analysed here.

  14. Patch test reactions to mite antigens: a GERDA multicentre study. Groupe d'Etudes et de Recherches en Dermato-Allergie.

    Science.gov (United States)

    Castelain, M; Birnbaum, J; Castelain, P Y; Ducombs, G; Grosshans, E; Jelen, G; Lacroix, M; Meynadier, J; Mougeolle, J M; Lachapelle, J M

    1993-11-01

    We performed patch tests with Dermatophagoides pteronyssinus (Dp) antigens from 2 different sources in 355 non-randomly selected patients with atopic dermatitis (AD) and 398 subjects of a control group. The study demonstrated that contact sensitization to mites occurred in an appreciable % of AD cases (20.8%), using commonly available assay products. The differences recorded between the 2 materials tested were related to the concentration of P1 antigen. Non-atopic patients rarely showed positive reactions to Dp (0.75%), when strict criteria for readings were applied and if 2 readings were performed. Patients with positive patch tests did not necessarily show positive immediate skin tests. It would be useful to carry out tests systematically in atopic patients, even if it is not yet known what modern treatment would be best for the patient. Laboratories still do not provide standardized house dust mite preparations--measuring and codifying their biological activity--for use in patch tests. It is to be hoped that the extension of this type of test will lead to the production of better test materials, in syringes with homogeneous dispersion and concentration.

  15. The prevalence of positive reactions in the atopy patch test with aeroallergens and food allergens in subjects with atopic eczema: a European multicenter study.

    Science.gov (United States)

    Darsow, U; Laifaoui, J; Kerschenlohr, K; Wollenberg, A; Przybilla, B; Wüthrich, B; Borelli, S; Giusti, F; Seidenari, S; Drzimalla, K; Simon, D; Disch, R; Borelli, S; Devillers, A C A; Oranje, A P; De Raeve, L; Hachem, J-P; Dangoisse, C; Blondeel, A; Song, M; Breuer, K; Wulf, A; Werfel, T; Roul, S; Taieb, A; Bolhaar, S; Bruijnzeel-Koomen, C; Brönnimann, M; Braathen, L R; Didierlaurent, A; André, C; Ring, J

    2004-12-01

    The atopy patch test (APT) was proposed to evaluate IgE-mediated sensitizations in patients with atopic eczema (AE). The prevalence and agreement with clinical history and specific IgE (sIgE) of positive APT reactions was investigated in six European countries using a standardized method. A total of 314 patients with AE in remission were tested in 12 study centers on clinically uninvolved, non-abraded back skin with 200 index of reactivity (IR)/g of house dust mite Dermatophagoides pteronyssinus, cat dander, grass, and birch pollen allergen extracts with defined major allergen contents in petrolatum. Extracts of egg white, celery and wheat flour with defined protein content were also patch tested. APT values were evaluated at 24, 48, and 72 h according to the European Task Force on Atopic Dermatitis (ETFAD) guidelines. In addition, skin-prick test (SPT) and sIgE and a detailed history on allergen-induced eczema flares were obtained. Previous eczema flares, after contact with specific allergens, were reported in 1% (celery) to 34% (D. pteronyssinus) of patients. The frequency of clear-cut positive APT reactions ranged from 39% with D. pteronyssinus to 9% with celery. All ETFAD intensities occured after 48 and 72 h. Positive SPT (16-57%) and elevated sIgE (19-59%) results were more frequent. Clear-cut positive APT with all SPT and sIgE testing negative was seen in 7% of the patients, whereas a positive APT without SPT or sIgE for the respective allergen was seen in 17% of the patients. APT, SPT and sIgE results showed significant agreement with history for grass pollen and egg white (two-sided Pr > /Z/ atopic controls, no positive APT reaction was seen. Aeroallergens and food allergens are able to elicit eczematous skin reactions after epicutaneous application. As no gold standard for aeroallergen provocation in AE exists, the relevance of aeroallergens for AE flares may be evaluated by APT in addition to SPT and sIgE. The data may contribute to the international

  16. Patch testing with Indian standard series

    Directory of Open Access Journals (Sweden)

    Narendra G

    2002-01-01

    Full Text Available Hundred patients (61 males, 39 females suspected to have allergic contact dermatitis were patch tested with Indian standard series (ISS. Forty four showed one or more positive reactions. The frequent sensitizers observed were nickel sulphate-12 (15%, potassium dichromate-11 (13.75%, cobalt chloride and colophony-7 (8.75% each, fragrance mix and thiuram mix-6 (7.5% each. The ISS differs from the European Standard Series by inclusion of propylene glycol, nitrofurazone, gentamicin, chlorocresol, PEG-400 and ethylenediamine chloride where assesquiterpene lactone mix and primin allergens are excluded.

  17. Results of patch testing in 10 patients with peristomal dermatitis.

    Science.gov (United States)

    Landis, Megan N; Keeling, James H; Yiannias, James A; Richardson, Donna M; Nordberg Linehan, Diane L; Davis, Mark D P

    2012-09-01

    Peristomal dermatitis is a common problem in patients with ostomies that is a source of considerable morbidity. Irritant contact dermatitis is most common, but allergic contact dermatitis can also occur. Because of the lack of published reports on patch testing for this indication, we undertook a retrospective study of patch testing results in patients with suspected peristomal allergic contact dermatitis. We sought to describe our patch testing experience with patients referred with peristomal dermatitis. This was a retrospective review of medical records of patients with ostomies and peristomal dermatitis who underwent patch testing in the Mayo Clinic Departments of Dermatology in Jacksonville, FL; Rochester, MN; and Scottsdale, AZ, during a 10-year period (2000-2010). Ten patients with peristomal dermatitis were referred for patch testing (6 in Minnesota, 2 in Florida, and 2 in Arizona). Patients were patch tested to the materials used in their stoma devices, to the standard series, and in some cases to supplemental series. All 10 had at least one allergic patch test reaction, most commonly to stoma paste (3 of 10 patients). Retrospective nature of study via chart review is a limitation. Patch testing is a useful tool for identification of allergens in patients with peristomal dermatitis. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Formaldehyde concentration in diagnostic patch testing

    DEFF Research Database (Denmark)

    Trattner, A; Johansen, J D; Menné, T

    1998-01-01

    Exposure to formaldehyde is common from both consumer products and industry. The reliability of the patch test is essential for the diagnosis of formaldehyde allergy as it is difficult to suspect from the patient's history. The recommended formaldehyde patch test concentration has been reduced over...

  19. Patch testing with constituents of Compositae mixes.

    Science.gov (United States)

    Paulsen, Evy; Andersen, Klaus E

    2012-05-01

    The development of mixes containing Compositae plant extracts has improved the diagnosis of Compositae contact allergy, but none of them has fulfilled the criteria for an ideal European plant mix. To evaluate which constituents of two commercial Compositae mixes were most useful as screening agents. These comprised 76 patients testing positive to Compositae mix 6% in petrolatum and 29 patients testing positive to Compositae mix 5% pet., all of whom were tested with constituents of the respective mixes. The majority of patients tested positive to parthenolide or parthenolide-containing extracts, followed by German chamomile, yarrow, and arnica. As German chamomile is a weak sensitizer, the results suggest cross-reactions or reactions to unknown allergens. No one was positive to Roman chamomile. Even though parthenolide seems to be a suitable supplement to the baseline series, the results emphasize that it is important to patch test with extracts of native or locally grown plants, not only because of the geographical variation, but also because of the potential unknown allergens contained in short ether preparations and the variability in the individual patient's exposure and cross-reaction patterns. © 2012 John Wiley & Sons A/S.

  20. Experimental patch testing with chromium-coated materials.

    Science.gov (United States)

    Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten S; Zachariae, Claus; Johansen, Jeanne D

    2017-06-01

    Chromium coatings on metal alloys can be decorative, and prevent corrosion and metal ion release. We recently showed that handling of a chromium-containing disc resulted in chromium deposition on the skin. To examine patch test reactivity to chromium-coated discs. We included 15 patients: 10 chromium-allergic patients, and 5 patients without chromium allergy. All were patch tested with potassium dichromate, cobalt chloride, nickel sulfate, and nine different metallic discs. The chromium-allergic patients were also patch tested with serial dilutions of potassium dichromate. Positive/weaker reactions were observed to disc B (1 of 10), disc C (1 of 10), and disc D, disc E, and disc I (4 of 10 each). As no controls reacted to any of the discs, the weak reactions indicate allergic reactions. Positive patch test reactions to 1770 ppm chromium(VI) in the serial dilutions of potassium dichromate were observed in 7 of 10 patients. When the case group was narrowed down to include only the patients with a current positive patch test reaction to potassium dichromate, elicitation of dermatitis by both chromium(III) and chromium(VI) discs was observed in 4 of 7 of patients. Many of the patients reacted to both chromium(III) and chromium(VI) surfaces. Our results indicate that both chromium(VI) and chromium(III) pose a risk to chromium-allergic patients. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Retrospective evaluation of the consequence of alleged patch test sensitization

    DEFF Research Database (Denmark)

    Jensen, Charlotte D; Paulsen, Evy; Andersen, Klaus E

    2006-01-01

    The risk of actively sensitizing a patient in connection with diagnostic patch tests exists. This risk, however, is extremely low, especially from standard allergens, and if the test is carried out according to internationally accepted guidelines. This retrospective study investigates the clinical...... or available for the follow-up investigation and 3 patients were not traceable. Among the 14 remaining patients 1 had a reaction to gold sodium thiosulphate, which was assessed to be a persistent reaction and not a late reaction, and in 2 patients a clear relevance for the late reacting allergen was found....... For the remaining 11 patients we could not rule out that they were patch test sensitized, and they were investigated further. 1 was diseased and 10 were interviewed regarding the possible consequences of the alleged patch test sensitization. 9 had not experienced any dermatitis problems, and 1 could not exclude...

  2. Variation in aluminium patch test reactivity over time.

    Science.gov (United States)

    Siemund, Ingrid; Mowitz, Martin; Zimerson, Erik; Bruze, Magnus; Hindsén, Monica

    2017-11-01

    Contact allergy to aluminium has been reported more frequently in recent years. It has been pointed out that positive patch test reactions to aluminium may not be reproducible on retesting. To investigate possible variations in patch test reactivity to aluminium over time. Twenty-one adults, who had previously reacted positively to aluminium, were patch tested with equimolar dilution series in pet. of aluminium chloride hexahydrate and aluminium lactate, four times over a period of 8 months. Thirty-six of 84 (43%) serial dilution tests with aluminium chloride hexahydrate and 49 of 84 (58%) serial dilution tests with aluminium lactate gave negative results. The range of reactivity varied between a negative reaction to aluminium chloride hexahydrate at 10% and/or to aluminium lactate at 12%, and a positive reaction to aluminium chloride hexahydrate at 0.1% and/or to aluminium lactate at 0.12%. The highest individual difference in test reactivity noticed was 320-fold when the two most divergent minimal eliciting concentrations were compared. The patch test reactivity to aluminium varies over time. Aluminium-allergic individuals may have false-negative reactions. Therefore, retesting with aluminium should be considered when there is a strong suspicion of aluminium contact allergy. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Photopatch and UV-irradiated patch testing in photosensitive dermatitis

    Directory of Open Access Journals (Sweden)

    Reena Rai

    2016-01-01

    Full Text Available Background: The photopatch test is used to detect photoallergic reactions to various antigens such as sunscreens and drugs. Photosensitive dermatitis can be caused due to antigens like parthenium, fragrances, rubbers and metals. The photopatch test does not contain these antigens. Therefore, the Indian Standard Series (ISS along with the Standard photopatch series from Chemotechnique Diagnostics, Sweden was used to detect light induced antigens. Aim: To detect light induced antigens in patients with photosensitive dermatitis. Methods: This study was done in a descriptive, observer blinded manner. Photopatch test and ISS were applied in duplicate on the patient's back by the standard method. After 24 hours, readings were recorded according to ICDRG criteria. One side was closed and other side irradiated with 14 J/cm2 of UVA and a second set of readings were recorded after 48 hrs. Result: The highest positivity was obtained with parthenium, with 18 out of 35 (51% patients showing a positive patch test reaction with both photoallergic contact dermatitis and photoaggravation. Four patients (11% showed positive patch test reaction suggestive of contact dermatitis to potassium dichromate and fragrance mix. Six patients had contact dermatitis to numerous antigens such as nickel, cobalt, chinoform and para-phenylenediamine. None of these patients showed photoaggravation on patch testing. Conclusion: Parthenium was found to cause photoallergy, contact dermatitis with photoaggravation and contact allergy. Hence, photopatch test and UV irradiated patch test can be an important tool to detect light induced antigens in patients with photosensitive dermatitis.

  4. Results of patch testing with lavender oil in Japan.

    Science.gov (United States)

    Sugiura, M; Hayakawa, R; Kato, Y; Sugiura, K; Hashimoto, R

    2000-09-01

    We report the annual results of patch testing with lavender oil for a 9-year period from 1990 to 1998 in Japan. Using Finn Chambers and Scanpor tape, we performed 2-day closed patch testing with lavender oil 20% pet. on the upper back of each patient suspected of having cosmetic contact dermatitis. We compared the frequency of positive patch tests to lavender oil each year with those to other fragrances. We diagnosed contact allergy when patch test reactions were + or Japan, there has been a trend for aromatherapy using lavender oil. With this trend, placing dried lavender flowers in pillows, drawers, cabinets, or rooms has become a new fashion. We asked patients who showed a positive reaction to lavender oil about their use of dried lavender flowers. We confirmed the use of dried lavender flowers in 5 cases out of 11 positive cases in 1997 and 8 out of 15 positive cases in 1998. We concluded that the increase in patch test positivity rates to lavender oil in 1997 and 1998 was due to the above fashion, rather than due to fragrances in cosmetic products.

  5. Patch testing with the "sesquiterpene lactone mix"

    DEFF Research Database (Denmark)

    Ducombs, G; Benezra, C; Talaga, P

    1990-01-01

    6278 patients were patch tested with a sesquiterpene lactone mix (SL-mix) in 10 European clinics. 4011 patients were tested only with 0.1% SL-mix, 63 (approximately 1.5%) of whom were positive, with 26 (41%) of these cases being considered clinically relevant. There were no cases of active...

  6. Allergic contact dermatitis in Danish children referred for patch testing - a nationwide multicentre study

    DEFF Research Database (Denmark)

    Simonsen, Anne Birgitte; Deleuran, Mette; Mortz, Charlotte Gotthard

    2014-01-01

    -17 years, 25.1% had one or more positive patch test reactions. The associated relevance was 66.4%. The most common sensitizers were metals, fragrances, and hair dyes. The frequency of positive patch test reactions and allergic contact dermatitis was significantly higher among girls. CONCLUSIONS: Allergic...

  7. Our experience with atopy patch tests with aeroallergens.

    Science.gov (United States)

    Celakovská, Jarmila; Ettlerová, Kvetuse; Ettler, Karel; Vanecková, Jaroslava

    2013-01-01

    Aim of our study was to evaluate the importance of atopy patch testing with aeroallergens as a diagnostic method in patients suffering from atopic dermatitis. The complet dermatological and allergological examinations were performed in 29 patients; 10 men, 19 women with the average age of 27.8 years, min. 17, max. 57 years; with the median SCORAD 24.2 points, s.d. 13.3 points. Wormwood, grass, dog dander, cat dander, dermatophagoides pharinae, dermatophagoides pteronyssinus and birch pollen were examined in diagnostic procedures. Skin prick tests, specific IgE were examined; the atopy patch tests were performed with aeroallergens for skin prick tests in concentration 1 x skin prick tests. Specific IgE and skin prick tests to one or more tested aeroallergens were positive altogether in 27 patients; atopy patch tests were positive only in one of these patients. For atopy patch testing with aeroallergens the concentration of 1 x skin prick tests is low to confirme the eczematic reaction in patients suffering from allergy to inhallant allergens.

  8. Volatility of fragrance chemicals: patch testing implications.

    Science.gov (United States)

    Gilpin, Sarah J; Hui, Xiaoying; Maibach, Howard I

    2009-01-01

    Diagnostic and predictive patch testing to determine contact allergy due to fragrance materials requires applying a fixed dose of material to the skin. This dose can be affected by the volatile nature of fragrances; little data exist on how the loss of fragrance dose due to volatility affects patch testing. (1) To evaluate pH dependence and evaporation rates of two fragrance chemicals, geraniol, citronellol, and a common fragrance solvent, diethyl phthalate (DEP) and (2) Assess implications for predictive patch-testing methods for fragrances. pH analysis of each material at 1% for three values (4.0, 5.0, 7.0) was done over 40 hours. Volatility experiments for each material, nonradiolabeled and radiolabeled, were conducted over a 24-hour period, taking readings at six time points (5 minutes, 15 minutes, 40 minutes, 1 hour, 3 hours, and 24 hours). Evaporation rates were not sensitive to pH shifts from 4.0 to 7.0. Evaporation rates for nonradiolabeled materials were low: after 24 hours, geraniol lost 8.9%, citronellol 27.0% and DEP 14.5%. The volatility data for radiolabeled materials demonstrated that geraniol loses up to 39% of its dose, citronellol loses up to 26%, and DEP up to 14% within 40 minutes. The tendency of fragrance materials to evaporate can impact the dose being applied to the patch and therefore the result of the patch and ultimately the decision-making process regarding that fragrance material's safety. These data, developed with DEP, utilized in a predictive sensitization assay cannot be generalized.

  9. Is there a risk of active sensitization to PPD by patch testing the general population?

    Science.gov (United States)

    Thyssen, Jacob Pontoppidan; Menné, Torkil; Nielsen, Niels Henrik; Linneberg, Allan

    2007-08-01

    Para-phenylenediamine (PPD), a constituent of permanent hair dyes, may cause contact allergy in exposed individuals. It has previously been questioned whether a patch testing with PPD in population-based epidemiological studies is entirely safe. The Glostrup allergy studies patch tested the same cohort twice. In 1990, 567 persons were patch-tested and only one person had a (+) positive reaction to PPD. In 1998, 540 persons were re-invited to a new patch test and 365 (participation rate 68%) were re-tested. There were no positive reactions to PPD. These studies indicate that patch testing with PPD in individuals with no previous positive reactions to PPD or with only one previous positive reaction does not cause active sensitization and can be performed with minimal risk.

  10. Diagnostic accuracy of patch test in children with food allergy.

    Science.gov (United States)

    Caglayan Sozmen, Sule; Povesi Dascola, Carlotta; Gioia, Edoardo; Mastrorilli, Carla; Rizzuti, Laura; Caffarelli, Carlo

    2015-08-01

    The gold standard test for confirming whether a child has clinical hypersensitivity reactions to foods is the oral food challenge. Therefore, there is increasing interest in simpler diagnostic markers of food allergy, especially in children, to avoid oral food challenge. The goal of this study was to assess the diagnostic accuracy of atopy patch test in comparison with oral food challenge. We investigated 243 children (mean age, 51 months) referred for evaluation of suspected egg or cow's milk allergy. Skin prick test and atopy patch test were carried out, and after a 2 weeks elimination diet, oral food challenge was performed. Two hundred and forty-three children underwent OFC to the suspected food. We found clinically relevant food allergies in 40 (65%) children to egg and in 22 (35%) to cow's milk. The sensitivity of skin prick test for both milk and egg was 92%, specificity 91%, positive predictive value 35%, and negative predictive value of 93%. Sensitivity, specificity, positive predictive value, and negative predictive value of atopy patch test for both milk and egg were 21%, 73%, 20%, and 74%, respectively. Our study suggests that there is insufficient evidence for the routine use of atopy patch test for the evaluation of egg and cow's milk allergy. OFC remains gold standard for the diagnosis of egg and milk allergy even in the presence of high costs in terms of both time and risks during application. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Investigation of contact allergy to dental materials by patch testing

    Directory of Open Access Journals (Sweden)

    Reena Rai

    2014-01-01

    Full Text Available Background: Dental products are widely used by patients and dental personnel alike and may cause problems for both. Dental materials could cause contact allergy with varying manifestations such as burning, pain, stomatitis, cheilitis, ulcers, lichenoid reactions localized to the oral mucosa in patients, and hand dermatitis in dental personnel. Patch testing with the dental series comprising commonly used materials can be used to detect contact allergies to dental materials. Aim: This study aimed to identify contact allergy among patients who have oral mucosal lesions after dental treatment and among dental personnel who came in contact with these materials. Materials and Methods: Twenty patients who had undergone dental procedures with symptoms of oral lichen planus, oral stomatitis, burning mouth, and recurrent aphthosis, were included in the study. Dental personnel with history of hand dermatitis were also included in the study. Patch testing was performed using Chemotechnique Dental Series and results interpreted as recommended by the International Contact Dermatitis Research Group (ICDRG. Results: Out of 13 patients who had undergone dental treatment/with oral symptoms, six patients with stomatitis, lichenoid lesions, and oral ulcers showed positive patch tests to a variety of dental materials, seven patients with ulcers had negative patch tests, seven dental personnel with hand dermatitis showed multiple allergies to various dental materials, and most had multiple positivities. Conclusion: The patch test is a useful, simple, noninvasive method to detect contact allergies among patients and among dental personnel dealing with these products. Long term studies are necessary to establish the relevance of these positive patch tests by eliminating the allergic substances, identifying clinical improvement, and substituting with nonallergenic materials.

  12. Patch testing in children from 2005 to 2012: results from the North American contact dermatitis group.

    Science.gov (United States)

    Zug, Kathryn A; Pham, Anh Khoa; Belsito, Donald V; DeKoven, Joel G; DeLeo, Vincent A; Fowler, Joseph F; Fransway, Anthony F; Maibach, Howard I; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Sasseville, Denis; Storrs, Frances J; Taylor, James S; Warshaw, Erin M; Zirwas, Matthew J

    2014-01-01

    Allergic contact dermatitis is common in children. Epicutaneous patch testing is an important tool for identifying responsible allergens. The objective of this study was to provide the patch test results from children (aged ≤18 years) examined by the North American Contact Dermatitis Group from 2005 to 2012. This is a retrospective analysis of children patch-tested with the North American Contact Dermatitis Group 65- or 70-allergen series. Frequencies and counts were compared with previously published data (2001-2004) using χ statistics. A total of 883 children were tested during the study period. A percentage of 62.3% had ≥1 positive patch test and 56.7% had ≥1 relevant positive patch test. Frequencies of positive patch test and relevant positive patch test reaction were highest with nickel sulfate (28.1/25.6), cobalt chloride (12.3/9.1), neomycin sulfate (7.1/6.6), balsam of Peru (5.7/5.5), and lanolin alcohol 50% petrolatum vehicle (5.5/5.1). The ≥1 positive patch test and ≥1 relevant positive patch test in the children did not differ significantly from adults (≥19 years) or from previously tested children (2001-2004). The percentage of clinically relevant positive patch tests for 27 allergens differed significantly between the children and adults. A total of 23.6% of children had a relevant positive reaction to at least 1 supplemental allergen. Differences in positive patch test and relevant positive patch test frequencies between children and adults as well as test periods confirm the importance of reporting periodic updates of patch testing in children to enhance clinicians' vigilance to clinically important allergens.

  13. Repeated patch testing to nickel during childhood do not induce nickel sensitization

    DEFF Research Database (Denmark)

    Søgaard Christiansen, Elisabeth

    2014-01-01

    Background: Previously, patch test reactivity to nickel sulphate in a cohort of unselected infants tested repeatedly at 3-72 months of age has been reported. A reproducible positive reaction at 12 and 18 months was selected as a sign of nickel sensitivity, provided a patch test with an empty Finn...

  14. Patch testing of 490 patients in Hong Kong.

    Science.gov (United States)

    Lee, T Y; Lam, T H

    1996-07-01

    Patch testing, using European standard allergens and suspected causative substances brought in by patients, was carried out in 490 patients with eczema in Hong Kong and 437 completed the test. Before patch testing, 244, 141 and 105 patients were diagnosed as having contact dermatitis, endogenous eczema and unclassified eczema, respectively. After patch testing, the diagnosis of the causal agent was changed in 54 contact dermatitis patients, and 18% of endogenous eczema patients and 34% of unclassified eczema patients were re-diagnosed as contact dermatitis. In the patients with a final diagnosis of contact dermatitis, 19.5% were positive to fragrance mix, followed by nickel sulfate (16.4%) and cobalt chloride (11.3%). The commonest causative agents for contact dermatitis were soap or detergent (22.0%) and traditional Chinese medicine (17.3%); the latter was a more common cause of contact dermatitis than Western medicine (9.0%) or metals (13.4%). The prevalence of allergic reaction to fragrance in Hong Kong was higher than among Chinese in Beijing, Shanghai, Taipei or Singapore (78% ethnic Chinese). Dermatologists should have a high index of suspicion about traditional medications and should patch test with the suspected substance when patients give a history of use.

  15. Patch Test Results of 775 Patients with Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Simin Ada

    2010-12-01

    Full Text Available Background and Design: The allergens responsible for allergic contact dermatitis vary among countries and even between different geographical regions within the same country over time. It is of great importance to perform the patch test at certain intervals, to evaluate the results in different centers and to compare them afterwards. Our aim was to evaluate the patch test results in our patients with allergic contact dermatitis.Material and Method: The records of the patients with allergic contact dermatitis, who had been patch tested between May 1997 and March 2009, were analyzed retrospectively. The demographic features such as age and sex, localization of the contact dermatitis, and the patch test results were recorded. Results: Of the 775 patients, 581 (75.2% were females and 194 (25% males. Of all patients, 735 were patch tested with the European Standard Series, 318 - with both the European Standard Series and cosmetic series, and 40-with cosmetic series alone. Of the patients tested with the European Standard Series, 255 (34.7% had at least one positive reaction. The most frequent allergen in the European Standard Series was nickel sulfate (17.3%, followed by cobalt chloride (7.2%, potassium dichromate (3%, fragrance mix (2.9%, and p-phenylenediamine base (2.6%. Of the 358 patients tested with cosmetic series, 82 (22.9% had at least one positive reaction. The 5 most frequently observed cosmetic series allergens were octyl gallate (3.9%, thimerosal (2.2%, sorbitan sesquioleate (2%, Euxyl K 400 (2% and methyldibromo glutaronitrile (1.4%. Conclusion: Our study shows the contact allergen profile of our center over 12 years. The most common allergens and their frequency differ between centers in various cities in Turkey. Those geographical differences should be re-evaluated by further studies performed in the certain time period. The high frequency of reactions to octyl gallate is an important finding in patients suspected of cosmetic allergy

  16. Patch test dose-response study of p-phenylenediamine

    DEFF Research Database (Denmark)

    Sosted, Heidi; Menné, Torkil; Johansen, Jeanne Duus

    2006-01-01

    The elicitation response in allergic contact dermatitis for the hair dye substance p-phenylenediamine (PPD) is dose dependent, but threshold concentrations have not previously been investigated. 15 PPD-sensitive patients participated in a serial dilution 48-hr patch test with PPD using 8...... concentrations of PPD ranging from 1 to 10 000 on the upper back. Petrolatum was applied as control. Three concentrations (50, 100 and 500 p.p.m. PPD) were also applied to the retroauricular area and on the lateral aspects of the upper arms. 14 of the 15 participants reacted to one or more of the test samples....... The threshold value for 10% of the tested persons (ED10) based on+or stronger reactions for PPD on the back was 38 p.p.m. (CI: 4.3-100). There were no statistically significant differences in the sensitivity of the three anatomical regions. The upper back is a suitable region for patch testing patients...

  17. Prevailence of Patch Test Positivity with Some Bases

    Directory of Open Access Journals (Sweden)

    J S Pasricha

    1987-01-01

    Full Text Available To evaluate the suitability of some chemicals to act as bases for antigens for patch tests, patch tests were performed with these agents in patients having contact dermatitis. Propylene glycol′used as such produced positive reactions in 25 (50% patients of which 12 were 2 + or more, polyethylene glycol 200 produced positive reactions in 9 (18% cases of which 4 cases were 2 + or more, a mixture of liquid paraffin and hard paraffin gave rise to positive reactions in 10 (10% cases 3 of these being 2 +, a mixture of liquid paraffin and bees wax was positive in 14 (14,Yo cases 3 of these being 2 +, yellow petrolatum was positive in 4 (8% cases, one of which was 2 +, white petrolatum was positive in S (6% cases all of these being + reactions only, and glycerol gave rise to a I + reaction in only one (2% caw. In tropical countries, water should be as base for as many antigens as possible for others, a control test with the b must be included.

  18. Contact allergy to popular perfumes; assessed by patch test, use test and chemical analysis.

    Science.gov (United States)

    Johansen, J D; Rastogi, S C; Menné, T

    1996-09-01

    The frequency of contact allergy to the 10 best-selling women's perfumes was studied in 335 consecutive female eczema patients by patch testing. The diagnostic ability of the fragrance mix, in relation to these products, was evaluated. Of eczema patients, 6.9% had a positive patch test to one or more of the perfumes, and 56.5% of these had a concurrent positive reaction to the fragrance mix. Hence, testing with the patients' own cosmetics is a significant part of diagnosing perfume allergy. The clinical relevance of the patch-test reactions to the commercial perfumes was equal to that of the fragrance mix, as judged from the patient's history and use testing with one of the perfumes. At least three of the chemically defined sensitizers in the fragrance mix were detected in all the perfumes by gas chromatography-mass spectrometry, which indicates that the fragrance mix is a good imitation of actual exposure.

  19. Contact allergy to popular perfumes; assessed by patch test, use test and chemical analysis

    DEFF Research Database (Denmark)

    Johansen, J D; Rastogi, Suresh Chandra; Menné, T

    1996-01-01

    The frequency of contact allergy to the 10 best-selling women's perfumes was studied in 335 consecutive female eczema patients by patch testing. The diagnostic ability of the fragrance mix, in relation to these products, was evaluated. Of eczema patients, 6.9% had a positive patch test to one...... or more of the perfumes, and 56.5% of these had a concurrent positive reaction to the fragrance mix. Hence, testing with the patients' own cosmetics is a significant part of diagnosing perfume allergy. The clinical relevance of the patch-test reactions to the commercial perfumes was equal...... to that of the fragrance mix, as judged from the patient's history and use testing with one of the perfumes. At least three of the chemically defined sensitizers in the fragrance mix were detected in all the perfumes by gas chromatography-mass spectrometry, which indicates that the fragrance mix is a good imitation...

  20. The relevance of 7-day patch test reading.

    Science.gov (United States)

    Higgins, Eleanor; Collins, Paul

    2013-01-01

    Patch test readings are usually performed on day 2 (48 hours) and day 4 (96 hours). However, reports in the literature identify delayed allergy to metals, corticosteroids, antibiotics, some preservatives, acrylic and methacrylic monomers and p-phenylenediamine. The aim of our study was to identify the benefit of performing a day 7 (168 hours) reading to identify relevant late positive reactions. Two hundred three consecutive patients were patch tested to the British Society for Cutaneous Allergy standard series with additional test series selected according to clinical history and applied at the same time. Twenty-six patients (12.8%) had new positive reactions on day 7 (168 hours), with 28 relevant positive reactions to 21 allergens. These included mercury 0.5% (2/26); cobalt chloride 1% (2/26); colophony 20% (2/26); disperse blue mix 106/124 1% (2/26); preservatives (4/26) that included Methylchloroisothiazolinone/methylisothiazolinone, sodium metabisulfite, and diazolidinyl urea; fragrances (7/26); and gentamycin sulfate 20% (1/26). These results confirm findings in the literature and support the argument for performing a day 7 reading (168 hours) to identify relevant late positive reactions.

  1. Non-IgE-related diagnostic methods (LST, patch test).

    Science.gov (United States)

    Matsumoto, Kenji

    2015-01-01

    Although most food allergy patients have immediate-type reactions, some have delayed-type reactions. Unlike for the detection of food-specific IgE antibody in immediate-type (IgE-mediated) food allergies, only a few tests are currently available to aid in the diagnosis of delayed-type (non-IgE-mediated) food allergies. This chapter summarizes our current understanding of one in vitro test and one in vivo test for non-IgE-mediated food allergies: the lymphocyte stimulation test (LST) and the atopy patch test (APT). Although the LST is not yet standardized, a food protein-specific LST might be a useful tool for diagnosing delayed-type food allergies, and especially those manifesting with gastrointestinal symptoms but not skin symptoms. Various remaining issues - including basophil contamination of the peripheral blood mononuclear cell fraction and lipopolysaccharide contamination of food antigen preparations - are also discussed. The APT uses an epicutaneous patch technique to occlusively apply food antigens to the skin to induce inflammatory reactions at the patch application site. Because the APT shows modest sensitivity and specificity, the clinical benefit of the APT in the diagnosis of food allergies in patients with atopic dermatitis is limited. A position paper on the APT issued by the European Academy of Allergy and Clinical Immunology/Global Allergy and Asthma European Network in 2006 is briefly summarized, and several recent APT-related topics, including APT use for the diagnosis of food protein-induced enterocolitis syndrome, are discussed. © 2015 S. Karger AG, Basel.

  2. Patch testing in Australia: Is it adequate?

    Science.gov (United States)

    Tizi, Stephanie; Nixon, Rosemary L

    2016-08-01

    Patch testing (PT) is essential for making the diagnosis of allergic contact dermatitis (ACD). However, the extent of PT undertaken by Australian dermatologists is unknown. The objectives of this study were to determine the rate and type of PT in Australia, the perceived obstacles to PT, and to explore the exposure to PT in dermatology training. Data were collected on private PT (analysing Medicare item numbers) and public hospital-based PT (estimated via verbal reports). An online survey on PT was sent to Fellows of the Australasian College of Dermatologists. It was found that total PT numbers, combining Medicare item number and public hospital data, were below the suggested optimum in all states and in Australia overall. Of the 173 respondents to the survey, 61% reported they patch tested and 78% reported they referred for PT. TrueTest was the most commonly used PT system, although it is known to be inadequate. Dermatologists who PT as registrars were significantly more likely to PT as consultants (P value = 0.0029). Cost, expertise required and staffing were considered major obstacles to performing PT. Accessibility and cost to the patient were common obstacles to referral. The combination of suboptimal PT rates and inadequate PT means that patients are missing out on being diagnosed with ACD in Australia. Increasing the exposure of registrars to PT, supporting specialised centres, the development of the Australian Baseline Series and the Contact Allergen Bank will, it is hoped, improve the rates of comprehensive PT in Australia. © 2015 The Australasian College of Dermatologists.

  3. Visual and confocal microscopic interpretation of patch tests to benzethonium chloride and benzalkonium chloride.

    Science.gov (United States)

    Benjamin, Bohaty; Chris, Fricker; Salvador, González; Melissa, Gill; Susan, Nedorost

    2012-08-01

    Quaternary ammonium compounds (Quats), such as benzalkonium chloride (BAC) and benzethonium chloride (BEC), are widely used as antibacterial active ingredients and preservatives in personal care products, disinfectants, and ophthalmic preparations. BAC is known to be a marginal irritant when patch tested at 0.15% aq. Data on BEC are limited. To differentiate irritant from allergic patch test reactions to quaternary ammonium compounds. Eight subjects who were considered likely to react based on history of rash after exposure to disinfectants or a history of prior positive patch test to BAC were recruited, as well as two patients undergoing routine patch testing. BAC (0.15% aq), BAC (0.15% pet), BEC (0.05% aq), BEC (0.15% pet), BEC (0.15% aq), BEC (0.5% aq), sodium lauryl sulfate (2.0%), and deionized water were applied under Finn chambers for 48 h. Four days and 7 days after application, the sites were examined visually and then by in vivo reflectance confocal microscopy (RCM) which was interpreted by blinded experts. Two patients with definite allergic reactions according to visual patch test reads and RCM were clinically relevant. Cross-reaction between BEC and BAC was demonstrated in one patient. RCM imaging correlated well with clinical scoring and interpretation of patch test reactions in terms of irritancy vs. allergy for BEC and BAC. Relevant allergic reactions to quats occur in humans. Possible cross-reaction was noted to occur between BAC and BEC. RCM appears to be a useful tool in distinguishing between irritancy and sensitization during patch testing to BAC and BEC. Further study of prevalence and best test concentration and vehicle is needed. © 2011 John Wiley & Sons A/S.

  4. Reactivity to patch tests with nickel sulfate and fragrance mix in infants

    DEFF Research Database (Denmark)

    Jøhnke, H; Norberg, L A; Vach, W

    2004-01-01

    sulfate in 3 concentrations, 200, 66 and 22 microg/cm(2), and fragrance mix 430 microg/cm(2) were used. A likely case of nickel sensitivity was defined as a reproducible positive reaction with at least homogeneous erythema and palpable infiltration occurring at least 2x and present at both the 12 and 18......The pattern of patch test reactivity to nickel sulfate and fragrance mix was studied with respect to patch test performance, reproducibility and clinical relevance in a population of unselected infants followed prospectively from birth to 18 months of age. TRUE Testtrade mark patches with nickel...... sensitivity was found in only 1 child. No reproducible positive reaction to fragrance mix was found. The high proportion of transient patch test reactivity to nickel sulfate 200 microg/cm(2) indicates that this standard concentration used for adults cannot be applied to infants. The interpretation of a single...

  5. Stability of fragrance patch test preparations applied in test chambers.

    Science.gov (United States)

    Mowitz, M; Zimerson, E; Svedman, C; Bruze, M

    2012-10-01

    Petrolatum patch test preparations are for practical reasons often applied in test chambers in advance, several hours or even days before the patient is tested. As many fragrance compounds are volatile it may be suspected that petrolatum preparations applied in test chambers are not stable over time. To investigate the stability of petrolatum preparations of the seven chemically defined components in the fragrance mix (FM I) when stored in test chambers. Samples of petrolatum preparations applied in test chambers stored at room temperature and in a refrigerator for between 4 and 144 h were analysed using liquid chromatographic methods. The concentration decreased by ≥ 20% within 8 h in four of seven preparations stored in Finn chambers at room temperature. When stored in a refrigerator only the preparation of cinnamal had decreased by ≥ 20% within 24 h. The stability of preparations of cinnamal stored in IQ chambers with a plastic cover was slightly better, but like the preparations applied in Finn chambers, the concentration decreased by ≥ 20% within 4 h at room temperature and within 24 h in a refrigerator. Cinnamal and cinnamyl alcohol were found to be more stable when analysed as ingredients in FM I compared with when analysed in individual preparations. Within a couple of hours several fragrance allergens evaporate from test chambers to an extent that may affect the outcome of the patch test. Application to the test chambers should be performed as close to the patch test occasion as possible and storage in a refrigerator is recommended. © 2012 The Authors. BJD © 2012 British Association of Dermatologists.

  6. Nickel patch test reactivity and the menstrual cycle

    DEFF Research Database (Denmark)

    Rohold, A E; Halkier-Sørensen, L; Thestrup-Pedersen, K

    1994-01-01

    Premenstrual exacerbation of allergic contact dermatitis and varying allergic patch test responses have been reported at different points of the period. Using a dilution series of nickel sulphate, we studied the variation in patch test reactivity in nickel allergic women in relation to the menstr......Premenstrual exacerbation of allergic contact dermatitis and varying allergic patch test responses have been reported at different points of the period. Using a dilution series of nickel sulphate, we studied the variation in patch test reactivity in nickel allergic women in relation...... were tested first on day 7-10 and the other half first on day 20-24. There was no difference in the degree of patch test reactivity, when the results from day 7-10 and day 20-24 were compared (p > 0.4). However, when we compared the patch test results from the first and second test procedure, we found...... of positive patch tests led to an increased skin reactivity towards the same allergen, when the patients were retested weeks later....

  7. Hydroxychloroquine-induced acute generalized exanthematous pustulosis with positive patch-testing.

    Science.gov (United States)

    Charfi, Ons; Kastalli, Sarrah; Sahnoun, Rym; Lakhoua, Ghozlane

    2015-01-01

    Acute generalized exanthematous pustulosis (AGEP) is a severe cutaneous adverse reaction, mostly induced by drugs. Hydroxychloroquine have been rarely reported in literature as a causative drug of this reaction. We report a case of AGEP induced by hydroxychloroquine with systemic involvement and confirmed by positive patch testing.

  8. Patch tests with fragrance mix II and its components.

    Science.gov (United States)

    Pónyai, Györgyi; Németh, Ilona; Altmayer, Anita; Nagy, Gabriella; Irinyi, Beatrix; Battyáni, Zita; Temesvári, Erzsébet

    2012-01-01

    Fragrance mix II (FM II) was initiated to detect contact hypersenstitivity (CH) to fragrances that could not have been identified previously. The aim of this multicenter study was to map the frequency of CH to FM II and its components in Hungary. Six centers participated in the survey from 2009 to 2010. A total off 565 patients (434 women and 131 men) with former skin symptoms provoked by scented products were patch tested. The tests were performed with Brial GmbH D-Greven allergens. In the environmental patch test series, FM II, FM I, Myroxylon pereirae, colophonium, wood-tar mix, propolis, and sesquiterpene lactone mix were tested as fragrance allergens. The FM II components (citral, farnesol, coumarin, citronellol, α-hexyl-cinnamaldehyde, and hydroxy-isohexyl-3-cyclohexene-carboxaldehyde [Lyral]) were also tested. Contact hypersenstitivity to any fragrances was detected in 28.8%, to FM II in 17.2% of the patients. Contact hypersenstitivity to hydroxy-isohexyl-3-cyclohexene-carboxaldehyde was observed in 7.3%, to coumarin in 5.1%, to α-hexyl-cinnamaldehyde in 3.5%, to citral in 3.4%, to farnesol in 2.5%, and to citronellol in 1.2%. Of the FM II-positive cases, 48.4% showed isolated CH reaction. The frequency of CH to FM II is 17.2% in the tested, selected Hungarian population. The CH to FM II and its components could not have been revealed without the present test materials.

  9. Experimental patch testing with chromium-coated materials

    DEFF Research Database (Denmark)

    Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten Stendahl

    2017-01-01

    Chromium coatings on metal alloys can be decorative, and prevent corrosion and metal ion release. We recently showed that handling of a chromium-containing disc resulted in chromium deposition on the skin. To examine patch test reactivity to chromium-coated discs. We included 15 patients: 10...... chromium-allergic patients, and 5 patients without chromium allergy. All were patch tested with potassium dichromate, cobalt chloride, nickel sulfate, and nine different metallic discs. The chromium-allergic patients were also patch tested with serial dilutions of potassium dichromate. Positive...

  10. Okeanos Explorer (EX1601): Transit and Mission Patch Test

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Normal underway operations and mapping patch testing. Bathymetric mapping of either the Murray or Molokai Fracture Zones during the transit to Hawaii is planned, as...

  11. Investigation of the homogeneity of methacrylate allergens in commercially available patch test preparations

    DEFF Research Database (Denmark)

    Mose, Kristian Fredløv; Andersen, Klaus Ejner; Christensen, Lars Porskjaer

    2013-01-01

    The homogeneity of methacrylates in commercial patch test preparations has not yet been investigated. Inhomogeneous patch test preparations may give rise to false-negative or false-positive patch test results in patients suspected of having methacrylate allergy.......The homogeneity of methacrylates in commercial patch test preparations has not yet been investigated. Inhomogeneous patch test preparations may give rise to false-negative or false-positive patch test results in patients suspected of having methacrylate allergy....

  12. Atopy patch tests in young adult patients with atopic dermatitis and controls

    DEFF Research Database (Denmark)

    Bygum, Anette; Mørtz, Charlotte G; Andersen, Klaus Ejner

    2003-01-01

    -dependent results were obtained with Dermatophagoides pteronyssinus, grass and cat with a reproducibility rate of 0.69 to 0.81 in patients and 0.60-0.96 in controls. A unique finding was a significant positive correlation between a positive atopy patch test, allergen dose and increase in transepidermal water loss......The clinical interpretation and reproducibility of atopy patch tests was studied in 23 selected young adult patients with atopic dermatitis and 25 healthy controls using standard inhalant allergens. Non-invasive measurements were used for objective assessment of test reactions and the participants...

  13. Evaluation of Desensol As a Standard Patch Test Kit

    Directory of Open Access Journals (Sweden)

    K C Shah

    1987-01-01

    Full Text Available In a study undertaken to find out the usefulness of ′Desensol′ patch test kit to detect contact allergens, in 200 cases revealed 24 cases with negative patch test with all the antigens and 55 cases reacted to even the Vaseline control. -Excluding these 79 cases, the common contact allergens were potassium bichr6ma,te, (40.49%, TMTD(28.92%, PPD(24.79%, epoxy resin (23.14%, colophony (19.0%, nickel sulfate (19.0%, Framycetin (19.0% and nitrofurazone (19.0%. Desensol patch test kit is lacking in certain antigens while in our country due to varied environmental factors and social customs, a person is exposed to a large number of natural and man-made contact allergens. So usefulness of such a kit like. Desensol is limited.

  14. Lyral has been included in the patch test standard series in Germany.

    Science.gov (United States)

    Geier, Johannes; Brasch, Jochen; Schnuch, Axel; Lessmann, Holger; Pirker, Claudia; Frosch, Peter J

    2002-05-01

    Lyral 5% pet. was tested in 3245 consecutive patch test patients in 20 departments of dermatology in order (i) to check the diagnostic quality of this patch test preparation, (ii) to examine concomitant reactions to Lyral and fragrance mix (FM), and (iii) to assess the frequency of contact allergy to Lyral in an unselected patch test population of German dermatological clinics. 62 patients reacted to Lyral, i.e. 1.9%. One third of the positive reactions were + + and + + +. The reaction index was 0.27. Thus, the test preparation can be regarded a good diagnostic tool. Lyral and fragrance mix (FM) were tested in parallel in 3185 patients. Of these, 300 (9.4%) reacted to FM, and 59 (1.9%) to Lyral. In 40 patients, positive reactions to both occurred, which is 13.3% of those reacting to FM, and 67.8% of those reacting to Lyral. So the concordance of positive test reactions to Lyral and FM was only slight. Based on these results, the German Contact Dermatitis Research Group (DKG) decided to add Lyral 5% pet. to the standard series.

  15. Is there a role of food additives in recurrent aphthous stomatitis? A prospective study with patch testing.

    Science.gov (United States)

    Gülseren, Duygu; Hapa, Asli; Ersoy-Evans, Sibel; Elçin, Gonca; Karaduman, Ayşen

    2017-03-01

    Recurrent aphthous stomatitis (RAS) is a common disease of the oral mucosa with an unknown etiology. This study aimed to determine if food additives play a role in the etiology of RAS as well as to determine if patch testing can be used to detect which allergens cause RAS. This prospective study included 24 patients with RAS and 22 healthy controls. All the participants underwent patch testing for 23 food additives. In total, 21 (87.5%) RAS patients and 3 (13.6%) controls had positive patch test reactions to ≥1 allergens; the difference in the patch test positivity rate between groups was significant (P food additives might play a role in the etiology of RAS and that patch testing could be a method for determining the etiology of RAS. © 2016 The International Society of Dermatology.

  16. A patch test confirmed phenobarbital-induced fixed drug eruption in a child.

    Science.gov (United States)

    Chadly, Zohra; Aouam, Karim; Chaabane, Amel; Belhadjali, Hichem; Abderrazzak Boughattas, Naceur; Zili, Jamel Eddine

    2014-06-01

    A-10-year-old girl was referred to our department for multiple hyperpigmented plaques. One week previously, she had been given one suppository of acetylsalicylic acid - phenobarbital for fever. Twelve hours after the drug intake the child developed pruritic red plaques on the left thigh. Six weeks after resolution of the acute reaction, patch tests were performed separately, with phenobarbital and acetylsalicylic acid. On 48-hour reading, only the phenobarbital patch test on residual pigmented lesion was positive. Because of possible cross-reactions between aromatic anticonvulsants, subsequent patch tests using carbamazepine and phenytoin on residual pigmented lesions were performed. They were all negative at 48-hour reading. To our knowledge, only two isolated pediatric cases of Phenobarbital-induced FDE have been reported in the literature. In this case report, as it was difficult to determine whether phenobarbital or acetylsalicylic acid was responsible for this reaction, subsequent patch tests allowed the identification of the culprit component since it was positive to phenobarbital.

  17. Evaluation of patients with oral lichenoid lesions by dental patch testing and results of removal of the dental restoration material

    Directory of Open Access Journals (Sweden)

    Emine Buket Şahin

    2016-12-01

    Full Text Available Background and Design: Oral lichenoid lesions (OLL are contact stomatitis characterized by white reticular or erosive patches, plaque-like lesions that are clinically and histopathologically indistinguishable from oral lichen planus (OLP. Amalgam dental fillings and dental restoration materials are among the etiologic agents. In the present study, it was aimed to evaluate the standard and dental series patch tests in patients with OLL in comparison to a control group and evaluate our results. Materials and Methods: Thirty-three patients with OLL or OLP and 30 healthy control subjects, who had at least one dental restoration material and/or dental filling, were included in the study. Both groups received standard series and dental patch test and the results were evaluated simultaneously. Results: The most frequent allergens in the dental series patch test in the patient group were palladium chloride (n=4; 12.12% and benzoyl peroxide (n=2, 6.06%. Of the 33 patients with OLL; 8 had positive reaction to allergents in the standard patch test series and 8 had positive reaction in the dental patch test series. There was no significant difference in the rate of patch test reaction to the dental and standard series between the groups. Ten patients were advised to have the dental restoration material removed according to the results of the patch tests. The lesions improved in three patients [removal of all amalgam dental fillings (n=1, replacement of all amalgam dental fillings with an alternative filling material (n=1 and replacement of the dental prosthesis (n=1] following the removal or replacement of the dental restoration material. Conclusion: Dental patch test should be performed in patients with OLL and dental restoration material. Dental filling and/or prosthesis should be removed/replaced if there is a reaction against a dental restoration material-related allergen.

  18. Patch testers' opinions regarding diagnostic criteria for metal hypersensitivity reactions to metallic implants.

    Science.gov (United States)

    Schalock, Peter C; Thyssen, Jacob P

    2013-01-01

    Metal hypersensitivity reactions to implanted devices remain a challenging and controversial topic. Diagnostic criteria and methods are not well delineated. Diagnostic criteria for hypersensitivity reactions after metallic device implantation are evaluated in this study by a multinational group of patch testers using Thyssen's previously published criteria. A total of 119 dermatologists at the 2012 European Contact Dermatitis Society and 2013 American Contact Dermatitis Society meetings answered a survey regarding their opinions on topics relating to metal hypersensitivity. Four major and 5 minor diagnostic criteria emerged. Approximately 80% of respondents found the following criteria useful (major criteria): chronic dermatitis beginning weeks to months after metallic implantation, eruption overlying the metal implant, positive patch test to a metal component of the implant, and complete clearing after removal of the potentially allergenic implant. Minor criteria (metals (eg, lymphocyte transformation test). In the challenging situation such as a symptomatic or failing orthopedic device, applying these 4 major criteria and the 5 supportive minor criteria may be useful for guiding decision making.

  19. The sensitivity of patch test in patients with psoriasis

    Directory of Open Access Journals (Sweden)

    Yavuz Yeşilova

    2010-09-01

    Full Text Available Objectives: Allergic diseases play an important role in the natural course of psoriasis. Atopic sensitization and con-tact dermatitis are common in patients with psoriasis. Since the symptoms are prolonged in patients who are resistant to therapy and exposure to itchy and external factors are common among these patients, the effects of contact aller-gens on triggering psoriasis are investigated. Contact allergens have an important role in activation and remission of psoriasis. We aimed to investigate contact sensitization rates in patients with psoriasis in the study.Material and Methods: Contact sensitization was investigated with the application of European standard series in twenty patients with psoriasis, twenty patients with contact dermatitis, and twenty healthy persons. Results: Among the whole study cases, positivity rate of patch test against one allergen at least was 25%. rate of patch test was 25% in patients with psoriasis, 35% in patients with contact dermatitis, and 15% in healthy persons. There were no significant differences between the groups according to sensitization to one or more allergens (p>0.05. There were no significant difference in clinical subgroup of psoriatic patients according to contact sensitiza-tion (p>0.05. The allergens in patients with psoriasis on patch test were as the followings: phenyldiamine, potassium dichromat, nickel, and cobalt.Conclusion: We think that the patch test has a major role in the diagnosis and elimination of allergens in patients with the chronic and resistant diseases and palmoplantar and flexural psoriasis.

  20. Patch testing for food-associated allergies in orofacial granulomatosis.

    LENUS (Irish Health Repository)

    Fitzpatrick, Laura

    2011-01-01

    Food-associated allergies, especially to benzoates and cinnamon-related compounds, have been associated with orofacial granulomatosis and both standard and urticarial patch testing have been used to detect such allergies. Elimination diets have also been shown to be effective in some patients.

  1. Patch testing with markers of fragrance contact allergy. Do clinical tests correspond to patients' self-reported problems?

    DEFF Research Database (Denmark)

    Johansen, J D; Andersen, T F; Veien, N

    1997-01-01

    in a questionnaire prior to patch testing with the European standard series. The questionnaire contained questions about skin symptoms from the use of scented and unscented products as well as skin reactions from contact with spices, flowers and citrus fruits that could indicate fragrance sensitivity. A highly...

  2. Allergic contact dermatitis from ophthalmic products: can pre-treatment with sodium lauryl sulfate increase patch test sensitivity?

    Science.gov (United States)

    Corazza, Monica; Virgili, Annarosa

    2005-05-01

    In patients suspected of allergic contact dermatitis because of topical ophthalmic medicaments, patch tests performed with patients' own products are often negative. The irritant anionic surfactant sodium lauryl sulfate (SLS) may alter the stratum corneum and increase antigen penetration. Pre-treatment of the skin with SLS 0.5% for 24 h was performed in the sites of patch tests with patients' own products in 15 selected patients. In patients previously negative to their own products tested with conventional patch tests, SLS pre-treatment showed 6 new relevant positive reactions and induced a stronger positive reaction in 1 patient. SLS pre-treatment could be proposed as an alternative promising method, which may increase sensitivity of patch tests with patients' own products.

  3. Monitoring contact sensitization to p-phenylenediamine (PPD) by patch testing with PPD 0.3% in petrolatum.

    Science.gov (United States)

    Geier, Johannes; Ballmer-Weber, Barbara K; Dickel, Heinrich; Frosch, Peter J; Bircher, Andreas; Weisshaar, Elke; Hillen, Uwe

    2013-07-01

    Being a contact allergen of general relevance, p-phenylenediamine (PPD) is patch tested in the baseline series. However, PPD 1% in petrolatum may actively sensitize. Patch testing with PPD at 0.35% pet. proved to be safe, as far as active sensitization is concerned. To determine whether PPD 0.3% pet. reliably detects PPD sensitization. Patch testing with PPD 0.3% pet. and 1% pet. synchronously was performed in consecutive patients in a multicentre study within the Information Network of Departments of Dermatology. Altogether, 2042 patients were patch tested. PPD 1% pet. yielded 6.0% positive reactions (n = 123), and PPD 0.3% pet. yielded 4.7% (n = 95). The synchronous reproducibility of PPD reactions was similar as known from parallel patch tests with identical PPD concentrations. The diagnostic properties of PPD 0.3% pet. expressed as reaction index and positivity ratio were good. Of the 123 patients reacting to PPD 1% pet., 32 (26%) had no positive reaction to PPD 0.3% pet. In 22 of these 32 patients (69%), no clinical relevance could be found. As patch testing with PPD 0.3% pet. is reliable according to our results, we recommend replacing PPD 1% pet. in the baseline series with PPD 0.3% pet. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Patch test results in patients with allergic contact dermatitis in Yozgat

    Directory of Open Access Journals (Sweden)

    Emine Çölgeçen Özel

    2013-09-01

    Full Text Available Background and Design: Patch testing is valuable in the diagnosis of allergic contact dermatitis (ACD as well as in determining the causative agent and thus is helpful in prevention of the disease and also provides information for the patient Material and Method: Hundred and sixty-eight patients (94 female and 74 male with ACD were patch tested with European standard series. Patch test result were assessed according to suggestion of International Contact Dermatitis Research Group at 48 and 72 hours after initial application. Results: Of the patients, 64.3% were between 16-45 years of age and majority of the lesions (57.1% were localized on the hands. A total of 86 (51.1% patients had one or more positive patch test reactions. The most common allergens were nickel sulfate (20.2% followed by potassium dichromate (8.3%, cobalt chloride (7.1%, fragrance mix (7.1%, paraphenylendiamine base (6%, paraben mix 3.6%, N-isopropyl-N-phenyl-p-phenylenediamine (3.6%, wool alcohols (3.6%, formaldehyde (3.6%, quaternium-15 (3.6%. Positive reactions to nickel sulfate were more common among women, especially those in younger group. Frequency of contact allergy to neomycin sulfate, epoxy resin, 4-tert-butylphenolformaldehyde resin, sesquiterpenelactone mix, primin, 5-chloro-2-methyl-4-isothiazolin-3-1, budesonide, lyral were relatively low (1.2%, while no positive reaction was obtained to clioquinol and methyldibromoglutaronitrile in any case. Conclusion: Since no similar study has been previously performed in our area, this study provides information about contact allergen profile in patients underwent skin patch test with a diagnosis of AKD at Yozgat. The most frequent allergens detected with ASS and frequency rates may vary among different facilities at various cities of Turkey. A standard series for our country may be created after assessment of regional variability by new studies conducted in same time zone.

  5. Pesticide patch test series for the assessment of allergic contact dermatitis among banana plantation workers in panama.

    Science.gov (United States)

    Penagos, Homero; Ruepert, Clemens; Partanen, Timo; Wesseling, Catharina

    2004-09-01

    Irritant contact dermatitis and allergic contact dermatitis (ACD) are frequent among agricultural workers and require targeted interventions. Patch testing is necessary for differential diagnosis, but patch testing with pesticides is uncommon. This study explores the frequency of ACD and sensitization to pesticides among highly exposed banana plantation workers. Frequently and recently used pesticides on banana plantations in Divala, Panama, were documented. A pesticide patch test tray specific for this population was prepared. A structured interview was administered to 366 participants, followed by a complete skin examination. The pesticide patch test series, as well as a standard patch test series, was applied to 37 workers with dermatoses likely to be pesticide related and to 23 control workers without dermatoses. The pesticide patch tests identified 15 cases (41%) of ACD (20 positive reactions) among the 37 workers diagnosed with pesticide dermatosis. Three controls had allergic reactions to pesticides (4 positive reactions). The pesticides were carbaryl (5 cases), benomyl (4 cases), ethoprophos (3), chlorothalonil (2), imazalil (2), glyphosate (2), thiabendazole (2), chlorpyrifos (1), oxyfluorfen (1), propiconazole (1), and tridemorph (1). Ethoprophos and tridemorph had not been previously identified as sensitizers. Thus, the prevalence of ACD was 0.03 (15 of 366). On the basis of observed prevalences of positive patch-test reactions among the subgroups with and without dermatoses, we estimated that > or = 16% of the entire population may be sensitized to pesticides. Sensitization to pesticides among banana plantation workers is a frequent occupational health problem. Pesticide patch test trays should be used in assessing skin diseases in highly exposed workers.

  6. Multicenter Patch Testing With Methylchloroisothizoline/Methylisothiazolinone in 100 and 200 ppm Within the International Contact Dermatitis Research Group

    DEFF Research Database (Denmark)

    Engfeldt, Malin; Ale, Iris; Andersen, Klaus E

    2017-01-01

    on literature reviews, it was recommended that the concentration of 0.02% aq. should be used in the international baseline series. OBJECTIVES: The aim of this study was to verify the recommendation from 2011 by comparing the patch test results from consecutive patch testing with MCI/MI 0.01% and 0...... in more adverse reactions. Methylchloroisothiazolinone/MI at 0.02% aq. should therefore be continuously used in the international baseline series....

  7. Designing and testing a wearable, wireless fNIRS patch.

    Science.gov (United States)

    Abtahi, Mohammadreza; Cay, Gozde; Saikia, Manob Jyoti; Mankodiya, Kunal

    2016-08-01

    Optical brain monitoring using near infrared (NIR) light has got a lot of attention in order to study the complexity of the brain due to several advantages as oppose to other methods such as EEG, fMRI and PET. There are a few commercially available functional NIR spectroscopy (fNIRS) brain monitoring systems, but they are still non-wearable and pose difficulties in scanning the brain while the participants are in motion. In this work, we present our endeavors to design and test a low-cost, wireless fNIRS patch using NIR light sources at wavelengths of 770 and 830nm, photodetectors and a microcontroller to trigger the light sources, read photodetector's output and transfer data wirelessly (via Bluetooth) to a smart-phone. The patch is essentially a 3-D printed wearable system, recording and displaying the brain hemodynamic responses on smartphone, also eliminates the need for complicated wiring of the electrodes. We have performed rigorous lab experiments on the presented system for its functionality. In a proof of concept experiment, the patch detected the NIR absorption on the arm. Another experiment revealed that the patch's battery could last up to several hours with continuous fNIRS recording with and without wireless data transfer.

  8. Patch testing with markers of fragrance contact allergy. Do clinical tests correspond to patients' self-reported problems?

    DEFF Research Database (Denmark)

    Johansen, J D; Andersen, T F; Veien, N

    1997-01-01

    The aim of the present study was to investigate the relationship between patients' own recognition of skin problems using consumer products and the results of patch testing with markers of fragrance sensitization. Eight hundred and eighty-four consecutive eczema patients, 18-69 years of age, filled...... in a questionnaire prior to patch testing with the European standard series. The questionnaire contained questions about skin symptoms from the use of scented and unscented products as well as skin reactions from contact with spices, flowers and citrus fruits that could indicate fragrance sensitivity. A highly...... significant association was found between reporting a history of visible skin symptoms from using scented products and a positive patch test to the fragrance mix, whereas no such relationship could be established to the Peru balsam in univariate or multivariate analysis. Our results suggest that the role...

  9. Suspected fragrance allergy requires extended patch testing to individual fragrance allergens.

    Science.gov (United States)

    Katsarma, G; Gawkrodger, D J

    1999-10-01

    This study has been performed to evaluate the efficacy of fragrance mix (FM) as a screen for fragrance allergy. Patients were included if they had had positive allergic reactions to FM, to 1 of the 8 ingredients of FM, to 1 of 14 other fragrance materials, or to their own perfume. 91 patients were studied. There were 65 women and 23 men (in 3, their sex was not recorded) allergic to FM on patch testing. The mean (+/-SD) age was 48.4+/-18.6 years. 22 patients gave a past history of atopic eczema. Dermatitis of the hands (31%) and face (26%) were the most common presenting complaints. 85 patients (93%) had a positive allergic patch test reaction to FM. 22 of the 40 tested to the extended fragrance series were positive to other perfumes as well, and of these, there were 14 reactions (in 9 patients) to allergens not in the FM. In addition, 6 patients were positive only to separately tested fragrance constituents and not to the FM. In conclusion, FM is an accurate screen for fragrance contact sensitivity. However, patch testing to an extended series is needed if there is clinical suspicion of perfume allergy, as otherwise about 7% of patients allergic to fragrances will be missed.

  10. Our experiences with the use of atopy patch test in the diagnosis of cow's milk hypersensitivity.

    Science.gov (United States)

    Pustisek, Nives; Jaklin-Kekez, Alemka; Frkanec, Ruza; Sikanić-Dugić, Nives; Misak, Zrinjka; Jadresin, Oleg; Kolacek, Sanja

    2010-01-01

    Atopy patch test has been recognized as a diagnostic tool for the verification of food allergies in infants and small children suffering from atopic dermatitis. The test also has a role in the diagnosis of food allergies characterized by clinical signs associated with the digestive system. Yet, in spite of numerous studies, the test itself has hitherto not been standardized. Our study enlisted 151 children less than two years of age, who exhibited suspect skin and/or gastrointestinal manifestations of food allergy to cow's milk, and in whom tests failed to prove early type of allergic reaction. Atopy patch test was positive in 28% of the children with atopic dermatitis, 43% of the children with suspect gastrointestinal manifestation and 32% of the children with skin and gastrointestinal manifestations of food allergy. In our experience, atopy patch test is an excellent addition to the hitherto used tests for the diagnosis of food allergies. It targets specifically delayed type hypersensitivity reactions, which are difficult to confirm with other diagnostic tools. It is furthermore simple to perform, noninvasive and produces a minimum of undesired side effects. For these reasons, it should become part of the routine diagnostic toolset for food allergies to cow's milk in infants and children, and applied before a food challenge test.

  11. p-Phenylenediamine sensitization is more prevalent in central and southern European patch test centres than in Scandinavian: results from a multicentre study

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Andersen, Klaus Ejner; Bruze, Magnus

    2009-01-01

    BACKGROUND: Positive patch test reactions to p-phenylenediamine (PPD) are common. PPD is used in oxidative hair dyes and is also present in dark henna temporary 'tattoos'. Cross-sensitization to other contact allergens may occur. Because subjects sensitized to PPD are at risk of clinically severe...... reactions upon hair dyeing, there is a need for 'current' prevalence data on PPD sensitization. OBJECTIVES: To compare PPD patch test results from dermatitis patients tested between 2003 and 2007 in 10 European patch test centres and to analyse the causes and determine relevance of positive PPD patch test...... reactions. MATERIALS: Patch testing was performed using PPD (1% free base in petrolatum from Trolab (Almirall Hermal GmbH, Reinbeck, Germany) or Chemotechnique (Malmö, Sweden), equivalent to 0.090 mg/cm(2) in the TRUE test from MEKOS Laboratories AS). Statistical analysis was performed using the chi...

  12. Patch test with ether extracts in salicaceae allergy

    Directory of Open Access Journals (Sweden)

    Sawhney M

    2002-01-01

    Full Text Available A total of 23 cases suggestive of airborne contact dermatitis were patch tested with ether extracts of flowers and leaves of populus sp. and salix sp. in a study conducted in Ladakh at an altitude of 3445 meters above sea level. Overall positivity was found in 12 (52.17%, with populus sp. alone in 7 (30. 43%, salix sp. alone in 4 17.39% and to both in one (8.33%.

  13. Is Patch Testing with Food Additives Useful in Children with Atopic Eczema?

    Science.gov (United States)

    Catli, Gonul; Bostanci, Ilknur; Ozmen, Serap; Dibek Misirlioglu, Emine; Duman, Handan; Ertan, Ulker

    2015-01-01

    Atopy patch testing is a useful way to determine delayed-type hypersensitivity reactions to foods and aeroallergens. Although food additives have been accused of worsening atopic eczema symptoms, according to recent studies the role of food additives in atopic eczema remains unclear. The purpose of our study was to investigate food additive hypersensitivity in a group of children with atopic eczema by using standardized atopy patch testing and to determine the role of food additive hypersensitivity in atopic eczema. Thirty-four children with atopic eczema and 33 healthy children were enrolled in the study. Children who consumed foods containing additives and did not use either antihistamines or local or systemic corticosteroids for at least 7 days prior to admission were enrolled in the study. All children were subjected to atopy patch testing and after 48 and 72 hours their skin reactions were evaluated by using the guidelines. Positive atopy patch test results were significantly higher in the atopic eczema group. Forty-one percent of the atopic eczema group (n = 14) and 15.2% (n = 5) of the control group had positive atopy patch test results with food additives (p = 0.036) (estimated relative risk 1.68, case odds 0.7, control odds 0.17). Carmine hypersensitivity and the consumption of foods containing carmine, such as gumdrops, salami, and sausage, were significantly higher in the children with atopic eczema. This is the first study investigating hypersensitivity to food additives in children with atopic eczema. Our results indicate that carmine may play a role in atopic eczema. © 2015 Wiley Periodicals, Inc.

  14. Recommendation to test limonene hydroperoxides 0·3% and linalool hydroperoxides 1·0% in the British baseline patch test series.

    Science.gov (United States)

    Wlodek, C; Penfold, C M; Bourke, J F; Chowdhury, M M U; Cooper, S M; Ghaffar, S; Green, C; Holden, C R; Johnston, G A; Mughal, A A; Reckling, C; Sabroe, R A; Stone, N M; Thompson, D; Wilkinson, S M; Buckley, D A

    2017-12-01

    There is a significant rate of sensitization worldwide to the oxidized fragrance terpenes limonene and linalool. Patch testing to oxidized terpenes is not routinely carried out; the ideal patch test concentration is unknown. To determine the best test concentrations for limonene and linalool hydroperoxides, added to the British baseline patch test series, to optimize detection of true allergy and to minimize irritant reactions. During 2013-2014, 4563 consecutive patients in 12 U.K. centres were tested to hydroperoxides of limonene in petrolatum (pet.) 0·3%, 0·2% and 0·1%, and hydroperoxides of linalool 1·0%, 0·5% and 0·25% pet. Irritant reactions were recorded separately from doubtful reactions. Concomitant reactions to other fragrance markers and clinical relevance were documented. Limonene hydroperoxide 0·3% gave positive reactions in 241 (5·3%) patients, irritant reactions in 93 (2·0%) and doubtful reactions in 110 (2·4%). Linalool hydroperoxide 1·0% gave positive reactions in 352 (7·7%), irritant reactions in 178 (3·9%) and doubtful reactions in 132 (2·9%). A total of 119 patients with crescendo reactions to 0·3% limonene would have been missed if only tested with 0·1% and 131 patients with crescendo reactions to 1·0% linalool would have been missed if only tested with 0·25%. In almost two-thirds of patients with positive patch tests to limonene and linalool the reaction was clinically relevant. The majority of patients did not react to any fragrance marker in the baseline series. We recommend that limonene hydroperoxides be tested at 0·3% and linalool hydroperoxides at 1·0% in the British baseline patch test series. © 2017 British Association of Dermatologists.

  15. North American Contact Dermatitis Group patch test results: 2009 to 2010.

    Science.gov (United States)

    Warshaw, Erin M; Belsito, Donald V; Taylor, James S; Sasseville, Denis; DeKoven, Joel G; Zirwas, Matthew J; Fransway, Anthony F; Mathias, C G Toby; Zug, Kathryn A; DeLeo, Vincent A; Fowler, Joseph F; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Maibach, Howard I

    2013-01-01

    Patch testing is an important diagnostic tool for determination of substances responsible for allergic contact dermatitis. This study reports the North American Contact Dermatitis Group (NACDG) patch testing results from January 1, 2009, to December 31, 2010. At 12 centers in North America, patients were tested in a standardized manner with a screening series of 70 allergens. Data were manually verified and entered into a central database. Descriptive frequencies were calculated, and trends were analyzed using χ2 statistics. A total of 4308 patients were tested. Of these, 2614 (60.7%) had at least 1 positive reaction, and 2284 (46.3%) were ultimately determined to have a primary diagnosis of allergic contact dermatitis. Four hundred twenty-seven (9.9%) patients had occupationally related skin disease. There were 6855 positive allergic reactions. As compared with the previous reporting period (2007-2008), the positive reaction rates statistically decreased for 20 allergens (nickel, neomycin, Myroxylon pereirae, cobalt, formaldehyde, quaternium 15, methydibromoglutaronitrile/phenoxyethanol, methylchlorisothiazolinone/methylisothiazolinone, potassium dichromate, diazolidinyl urea, propolis, dimethylol dimethylhydantoin, 2-bromo-2-nitro-1,3-propanediol, methyl methacrylate, ethyl acrylate, glyceryl thioglycolate, dibucaine, amidoamine, clobetasol, and dimethyloldihydroxyethyleneurea; P < 0.05) and statistically increased for 4 allergens (fragrance mix II, iodopropynyl butylcarbamate, propylene glycol, and benzocaine; P < 0.05). Approximately one quarter of tested patients had at least 1 relevant allergic reaction to a non-NACDG allergen. Hypothetically, approximately one quarter of reactions detected by NACDG allergens would have been missed by TRUE TEST (SmartPractice Denmark, Hillerød, Denmark). These results affirm the value of patch testing with many allergens.

  16. Patch testing in Israeli children with suspected allergic contact dermatitis: A retrospective study and literature review.

    Science.gov (United States)

    Zafrir, Yaron; Trattner, Akiva; Hodak, Emmillia; Eldar, Oren; Lapidoth, Moshe; Ben Amitai, Dan

    2018-01-01

    Childhood allergic contact dermatitis is recognized as a significant clinical problem. The objective was to evaluate the rate of positive patch tests in Israeli children with clinically suspected allergic contact dermatitis, identify possible sex and age differences, compare results with those in Israeli adults, and review pediatric studies in the literature. The study sample included 343 children and adolescents (197 female, 146 male; 1-18 years of age, mean age 11.8 years) with clinically suspected allergic contact dermatitis who underwent patch testing with a standard pediatric series of 23 allergens at a tertiary medical center from 1999 to 2012. Data on clinical characteristics and test results were collected retrospectively from the medical files. Ninety-eight subjects (28.6%) (75 girls [38.1%], 23 boys [15.8%]) had at least one positive reaction. The most frequent reactions were to nickel sulfate, followed by potassium dichromate and cobalt chloride. Nickel sulfate sensitivity was more common in girls, especially those younger than 3 years and older than 12 years. The prevalence of contact sensitization was similar in subjects with and without atopic dermatitis (50% and 51%, respectively). Nickel is the most common allergen in Israeli children, especially girls. Patch testing should be performed in children with clinically suspected allergic contact dermatitis regardless of atopic background. © 2017 Wiley Periodicals, Inc.

  17. Profile of irritant patch testing with detergents: sodium lauryl sulfate, sodium laureth sulfate and alkyl polyglucoside.

    Science.gov (United States)

    Löffler, H; Happle, R

    2003-01-01

    The cutaneous reaction to detergents follows distinct kinetic rules: the duration of application and the irritant concentration are of major importance. The aim of this study was to evaluate the differences in kinetics of skin reaction between the standard irritant sodium lauryl sulfate (SLS), and 2 modern detergents: sodium laureth sulfate (SLES) and alkyl polyglucoside (APG). We performed patch testing with SLS and SLES (or APG) at different concentrations (0.125, 0.25, 0.5, 1.0 and 2.0%) and with different exposure times (6, 12 and 24 h). Evaluation was conducted by measurement of transepidermal water loss (TEWL) and laser Doppler flowmetry (LD) 24 h, 7 and 10 days after patch removal. We found a pronounced reaction to SLS, and a far milder one to SLES. Even at the highest concentration the skin reaction to APG was hard to detect. During the regeneration period (day 3-10) SLS showed even at day 10 an increased TEWL at all concentrations tested. The irritation due to SLES was convincingly detectable only up to day 7, whereas the APG-tested skin areas showed no significant reaction even at day 3. These results demonstrate the improvement in reduction of skin irritation achieved by development of novel detergents.

  18. Patch-testing North American lip dermatitis patients: data from the North American Contact Dermatitis Group, 2001 to 2004.

    Science.gov (United States)

    Zug, Kathryn A; Kornik, Rachel; Belsito, Donald V; DeLeo, Vincent A; Fowler, Joseph F; Maibach, Howard I; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Rietschel, Robert L; Sasseville, Denis; Storrs, Frances J; Taylor, James S; Warshaw, Erin M

    2008-01-01

    The most common differential diagnoses for patients presenting with lip dermatitis or inflammation include atopic, allergic, and irritant contact dermatitis. Patch testing can be performed to identify the allergic contact conditions. To report North American Contact Dermatitis Group (NACDG) patch-test results of patients who presented for patch testing with only lip involvement from 2001 to 2004. Patient characteristics, allergen frequencies, relevance, final diagnoses, and relevant allergic sources not in the NACDG screening series were evaluated. The NACDG 2001-2004 database was used to select patients presenting with only lip involvement. Of 10,061 patients tested, 2% (n = 196) had lips as the sole involved site. Most (84.2%) were women. After patch testing, 38.3% (n = 75) were diagnosed with allergic contact cheilitis. Fragrance mix, Myroxilon pereirae, and nickel were the most common relevant allergens. Of 75 patients, 27 (36%) had relevant positive patch-test reactions to items not on the NACDG series; lipstick and cosmetics were the predominant sources. Patch testing is valuable in the evaluation and identification of contact allergy in patients referred for lip dermatitis. The use of supplementary allergens based on history and exposure is important in the identification of additional relevant allergens. Over a third of patients with contact allergy had other factors, such as irritant dermatitis, considered relevant to their condition.

  19. Level of use and safety of botanical products for itching vulvar dermatoses. Are patch tests useful?

    Science.gov (United States)

    Corazza, Monica; Virgili, Annarosa; Toni, Giulia; Minghetti, Sara; Tiengo, Silvia; Borghi, Alessandro

    2016-05-01

    Topical remedies based on botanical ingredients are popular. To assess: (i) the usage of botanical substances in subjects affected with itching and chronic vulvar complaints; (ii) the incidence of side-effects associated with their use and the frequency of contact allergy; (iii) the diagnostic usefulness of patch testing. Sixty-six patients were provided with a questionnaire to assess the prevalence and type of topical botanical preparations used and the occurrence of adverse reactions. Patients were patch tested with (i) the Italian baseline series, (ii) a topical medicament series, and (iii) a botanical series. Forty-two patients (63.6%) reported the use of natural topical products on the vulva. Seven (16.7%) noted adverse reactions; 27 showed positive reactions with the baseline series; 14 (21.2%) had at least one relevant reaction, mainly to allergens in topical products and cosmetics; and 2 (3%) showed positive reactions to the botanical series. Of the 7 patients complaining of adverse effects of botanical products, 3 (42.8%) showed relevant sensitization. The use of natural topical products is widespread among women affected with itching vulvar diseases. Contact dermatitis is a possible adverse effect. Botanical series are of questionable usefulness, owing to the wide variety of botanical ingredients. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Patch test results with patients' own perfumes, deodorants and shaving lotions: results of the IVDK 1998-2002.

    Science.gov (United States)

    Uter, W; Geier, J; Schnuch, A; Frosch, P J

    2007-03-01

    Assessment of the value of patch testing patients' own perfumes, eau de toilette, deodorants and shaving lotions with regard to diagnosing contact allergy to fragrances, and an analysis of the spectrum of concurrent patch test reactions to single fragrance allergens. Data of the Information Network of Departments of Dermatology (IVDK; http://www.ivdk.org) regarding patch test results with above products brought in by the patient, considered as possible cause of contact dermatitis, were retrospectively analysed. Between 1998 and 2002, 1468 patients were patch tested with 2557 single products (deodorants, n = 1094; eau de toilette, n = 598; perfume, n = 530; and pre- or after-shave, n = 325; remainder not classifiable), mostly 'as is'. Positive reactions were observed in 129 patients (to 191 products). In 58 of these patients, no further patch test reactions to the fragrance mix (FM-I), Myroxylon pereirae resin (balsam of Peru) or 4-(4-hydroxy-4-methyl-pentyl)-3-cyclohexencarboxaldehyde (e.g. Lyral(R)) were found. A strong association between contact sensitivity to the above commercial allergens and positive reactions to products was observed. Some single compounds such as ylang-ylang oil, propolis and especially oak moss absolute are important allergens in the 'perfume-positive' subgroup, but less in a subgroup positive to own deodorants. Patch testing this scope of products, brought in by the patient, can be regarded as a simple, safe and effective method to diagnose clinically relevant contact sensitization - the more so, as the composition of such products is ever-changing, and the sensitivity of established 'screening allergens' is thus insufficient.

  1. Patch tests in children: a review of 13 years of experience in comparison with previous data.

    Science.gov (United States)

    Milingou, Maria; Tagka, Anna; Armenaka, Melina; Kimpouri, Konstantina; Kouimintzis, Dimitris; Katsarou, Alexandra

    2010-01-01

    The true prevalence of allergic contact dermatitis (ACD) in children remains unknown. Our aim was to compare the results of patch tests in children with suspected ACD between two different periods of time and identify possible changes in emerging allergens. We compared contact allergens, gender, age distribution, and personal history of atopic dermatitis (AD), in correlation with the positivity of patch tests, between two equal periods of time (232 children tested during 1980-1993, period A, and 255 children during 1994-2007, period B) in the same region and in the same institution. Patch test positivity was 47.8% in period A, and 60% in period B (p = 0.083). The most common allergens in period A were: nickel sulfate (16.3%), cobalt chloride (8.6%), fragrance mix (7.3%), potassium dichromate (4.3%), and thimerosal only (1.7%). In period B, the allergen distribution was as follows: nickel sulfate (21.56%), thimerosal (18.03%), cobalt chloride (12.9%), potassium dichromate (9.4%), and fragrance mix (4.7%). Girls were more likely to have a positive patch test compared with boys, with reactions in 53% of girls and 39% of boys in period A (p = 0.003), and 61% of girls and 58% of boys in period B (p = 0.691). Twenty-nine per cent of patients with positive results had a personal history of AD in period A and 44% in period B (p = 0.015). Differences in the positivity of allergens between different time periods reflect changes in habits, of allergens exposure or preventive measures.

  2. Patch testing with hair cosmetic series in Europe

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Bensefa-Colas, Lynda; Frosch, Peter

    2015-01-01

    Many key ingredients of hair cosmetics (in particular, dyes, bleaches, and hair-styling agents) are potent (strong to extreme) contact allergens. Some heterogeneity is apparent from published results concerning the range of allergens for which patch testing is important. The objective...... of the present review was to collect information on the current practice of using 'hair cosmetic series', and discuss this against the background of evidence concerning consumer/professional exposure and regulatory aspects to finally derive a recommendation for a 'European hair cosmetic series'. The methods...... (Annex II of the Cosmetics Regulation). An up-to-date 'European hair cosmetics series', as recommended in the present article, should (i) include broadly used and/or potent contact allergens, (ii) eliminate substances of only historical concern, and (iii) be continually updated as new evidence emerges....

  3. Fragrance allergy could be missed without patch testing with 26 individual fragrance allergens.

    Science.gov (United States)

    Vejanurug, Patnapa; Tresukosol, Poohglin; Sajjachareonpong, Praneet; Puangpet, Pailin

    2016-04-01

    In 2003, the EU Cosmetics Directive stated that 26 fragrance substances must be listed on the cosmetic product ingredient labels. Not all of these 26 fragrance substances are detected by the usual screening markers comprising fragrance mix I, fragrance mix II, and Myroxylon pereirae. To evaluate the usefulness of testing with the 26 individual fragrance substances in addition to the standard fragrance screening markers. Three hundred and twelve consecutive patients were patch tested with our baseline series and the 26 specific fragrance substances required to be declared on cosmetic product ingredient labels in accordance with the EU Cosmetics Directive. Positive reactions to at least either one of the 26 individual fragrance substances or the usual fragrance screening markers were seen in 84 of 312 patients (26.9%). Fifteen of these 84 patients (17.8%) reacted negatively to the fragrance screening markers. The most common individual fragrance allergens were cinnamyl alcohol (11.2%), cinnamal (9%), and hydroxycitronellal (3.8%). Sixty-two of 312 patients (19.8%) had at least one positive reaction to the fragrance screening markers. Additional patch testing with the 26 individual fragrance allergens, or with the commonest fragrance allergens identified within these 26, should be performed to optimize the detection of fragrance allergy. Cinnamyl alcohol and cinnamal are important fragrance allergens in Thailand. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Patch test concentrations (doses in mg/cm2 ) for the 12 non-mix fragrance substances regulated by European legislation.

    Science.gov (United States)

    Bruze, Magnus; Svedman, Cecilia; Andersen, Klaus Ejner; Bruynzeel, Derk; Goossens, An; Johansen, Jeanne Duus; Matura, Mihaly; Orton, David; Vigan, Martine

    2012-03-01

    According to EU legislation, 26 fragrance substance allergens must be labelled on cosmetic products. For 12 of them, the optimal patch test concentration/dose has not been evaluated. To establish the optimal patch test doses in mg/cm2 for the 12 fragrance substances that are not included in fragrance mix I or II in the European baseline patch test series. Patch testing with the 12 fragrance substances was performed in a stepwise manner encompassing up to five rounds in at least 100 dermatitis patients for each round. Before patch testing, an individual maximum concentration/dose was determined for each fragrance substance. The predetermined maximum patch test concentrations/doses could be tested for all 12 fragrance substances, with no observable adverse reactions being noted. For each fragrance substance investigated, it is recommended that half of the maximum patch test dose (mg/cm2) be used for aimed and screening patch testing. © 2012 John Wiley & Sons A/S.

  5. Immunophenotyping of the cutaneous cellular infiltrate after atopy patch testing in cats with atopic dermatitis.

    Science.gov (United States)

    Roosje, P J; Thepen, T; Rutten, V P M G; van den Brom, W E; Bruijnzeel-Koomen, C A F M; Willemse, T

    2004-10-01

    Cats with spontaneously occurring atopic dermatitis have clinical and immunocytochemical characteristics compatible with these in humans with atopic dermatitis (AD). The atopy patch test (APT) has proven to be a valuable tool in elucidating the disease process in humans. Additionally, the APT is very specific and bypasses the problem of conflicting results due to differences in chronicity of lesions of AD patients. We adapted the APT for use in cats to explore the suitability of the APT as a tool to study the onset of allergic inflammation in cats with atopic dermatitis. APT were performed in AD cats (n = 6) and healthy cats (n = 10). All cats were patch tested with two allergens in three different dilutions and a diluent control. The allergens for the APT were selected from positive intradermal test and /or prick test results and consisted of: Dermatophagoides farinae, D. pteronyssinus, Tyrophagus putrescentiae, and a grass pollen mixture. APT were read after 10, 24 and 48 h, and punch biopsies for immunohistochemical evaluation were collected at these time points. Macroscopically positive APT reactions were observed in three out of six cats at 24 and/or 48 h with allergen concentrations of 25,000 and 100,000 NU/ml. Reactions were not observed at negative control sites and neither in control animals. A significantly increased number of IL-4+, CD4+, CD3+, MHC class II+ and CD1a+ cells was found in one AD cat with positive APT reactions. Five out of six AD cats had significantly increased IL-4+ T cell numbers at 24 and/or 48 h. Our data indicate that in cats, macroscopically positive patch test reactions can be induced, which have a cellular infiltrate similar to that in lesional skin. We found a high specificity and a macroscopically positive APT reaction in half of the cats, which is similar to what is seen in humans. Hence, the APT in cats might be a useful tool in studying the immunopathogenesis of feline atopic dermatitis.

  6. Quantitative aspects of isoeugenol contact allergy assessed by use and patch tests

    DEFF Research Database (Denmark)

    Johansen, J D; Andersen, K E; Menné, T

    1996-01-01

    The clinical implications of sensitization to the fragrance material isoeugenol were studied in 19 subjects. Patch testing with serial dilutions of isoeugenol and a repeated open application test (ROAT) were performed. The minimum effect level under patch test conditions was below 0.01% isoeugenol...

  7. Patch testing with markers of fragrance contact allergy. Do clinical tests correspond to patients' self-reported problems?

    Science.gov (United States)

    Johansen, J D; Andersen, T F; Veien, N; Avnstorp, C; Andersen, K E; Menné, T

    1997-03-01

    The aim of the present study was to investigate the relationship between patients' own recognition of skin problems using consumer products and the results of patch testing with markers of fragrance sensitization. Eight hundred and eighty-four consecutive eczema patients, 18-69 years of age, filled in a questionnaire prior to patch testing with the European standard series. The questionnaire contained questions about skin symptoms from the use of scented and unscented products as well as skin reactions from contact with spices, flowers and citrus fruits that could indicate fragrance sensitivity. A highly significant association was found between reporting a history of visible skin symptoms from using scented products and a positive patch test to the fragrance mix, whereas no such relationship could be established to the Peru balsam in univariate or multivariate analysis. Our results suggest that the role of Peru balsam in detecting relevant fragrance contact allergy is limited, while most fragrance mix-positive patients are aware that the use of scented products may cause skin problems.

  8. Multicenter Patch Testing With Methylisothiazolinone and Methylchloroisothiazolinone/Methylisothiazolinone Within the International Contact Dermatitis Research Group.

    Science.gov (United States)

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus E; Elsner, Peter; Goh, Chee-Leok; Goossens, An; Jerajani, Hemangi; Matsunaga, Kayoko; McFadden, John; Bruze, Magnus

    The preservatives methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) and MI are well-known contact sensitizers. Recently, an increase in the contact allergy frequency for MI 0.2% aqueous (aq) has been seen in many European countries paralleled with an increase in MCI/MI allergy. Many of the MI-allergic patients do not react to MCI/MI 0.01% or 0.02% because the concentration of MI in these preparations is too low (25 and 50 ppm, respectively) to elicit a positive patch test reaction. The aims of this study were to investigate the prevalence of contact allergy to MI in the participating clinics representing various countries all over the world, to assess how many additional individuals with contact allergy are found by testing MI 0.2% aq in parallel with MCI/MI 0.02%, and to assess the clinical relevance of MI and MCI/MI allergies. In 9 dermatology clinics representing 9 countries, 3865 consecutive patients with dermatitis were patch tested with MI 0.2% aq and in parallel with MCI/MI 0.02% aq, provisionally included into the baseline series. An assessment of clinical relevance in those allergic to MI was also made. Contact allergy to MI was found in 284 patients (7.3%). The frequency of contact allergy varied from 0.8% to 10.9% in different centers. Simultaneous reactivity to 200 ppm of MCI/MI was found in 67.3% of the MI-positive patients. Contact allergy to MI alone without any simultaneous contact allergy to 200 ppm of MCI/MI was diagnosed in 93 patients (32.7%; 2.4% of all tested patients). The contact allergy to MI and/or MCI/MI could explain or contribute to dermatitis in more than 60% of the MI-allergic patients. Methylisothiazolinone of 2000 ppm needs to be patch tested on its own to not miss contact allergy.

  9. Selective versus routine patch metal allergy testing to select bar material for the Nuss procedure in 932 patients over 10years.

    Science.gov (United States)

    Obermeyer, Robert J; Gaffar, Sheema; Kelly, Robert E; Kuhn, M Ann; Frantz, Frazier W; McGuire, Margaret M; Paulson, James F; Kelly, Cynthia S

    2018-02-01

    The aim of the study was to determine the role of patch metal allergy testing to select bar material for the Nuss procedure. An IRB-approved (11-04-WC-0098) single institution retrospective, cohort study comparing selective versus routine patch metal allergy testing to select stainless steel or titanium bars for Nuss repair was performed. In Cohort A (9/2004-1/2011), selective patch testing was performed based on clinical risk factors. In Cohort B (2/2011-9/2014), all patients were patch tested. The cohorts were compared for incidence of bar allergy and resultant premature bar loss. Risk factors for stainless steel allergy or positive patch test were evaluated. Cohort A had 628 patients with 63 (10.0%) selected for patch testing, while all 304 patients in Cohort B were tested. Over 10years, 15 (1.8%) of the 842 stainless steel Nuss repairs resulted in a bar allergy, and 5 had a negative preoperative patch test. The incidence of stainless steel bar allergy (1.8% vs 1.7%, p=0.57) and resultant bar loss (0.5% vs 1.3%, p=0.23) was not statistically different between cohorts. An allergic reaction to a stainless steel bar or a positive patch test was more common in females (OR=2.3, pbar allergies occur at a low incidence with either routine or selective patch metal allergy testing. If selective testing is performed, it is advisable in females and patients with a personal or family history of metal sensitivity. A negative preoperative patch metal allergy test does not preclude the possibility of a postoperative stainless steel bar allergy. Level III Treatment Study and Study of Diagnostic Test. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Patch testing for allergic contact dermatitis: Three years retrospective results in Tekirdağ

    Directory of Open Access Journals (Sweden)

    Gamze Erfan

    2015-06-01

    Full Text Available Background and Design: Allergic contact dermatitis is a delayed type hypersensitivity reaction to allergens in individuals who were sensitized with same allergens before. The causative allergens may change in time as well as vary among geographical and population based differences. Materials and Methods: The characteristics of 169 patients-107 (63.3% male, 62 (36.7% female, who patch tested between 2011- 2014 with allergic contact dermatitis diagnosis and test results were retrospectively analysed. Results: The mean age of all patients who had the most frequent occupation as service sector/house wife (26.6% were 41.06 years and the mean disease duration of all patients was 19.5 months. The most frequent localization of disease was hands (n: 105,%73 and %50.3 of patients had positivity with at least one allergen. The most frequent seven allergens with positivity were nickel sulfate (n: 50, %29.6, cobalt chloride (n: 23, %13.6, potassium dichromate (n: 22, %13, sesquiterpene lactone mix (n: 18, %10.7, thiuram (n: 10, %5.9, clioquinol mix (n: 10, %5.9 and 4-tert-butilfenol formaldehyde resin (n: 10, %5.9, respectively. On the other hand in all patients there were no positivity with N-Isopropyl-N-phenyl-4-phenylenediamine, epoxy resin, balsam of peru, formaldehyde, quaternium-15, primin, tixocortol-21-pivalate, fragrance mix-2. Conclusion: In comparison of this study which first reports patch test results of patients in Tekirdağ-a city in Trakya region and other studies that report patch test results of different regions of our country; the mean age of patients of present study were older and there were similar results for occupations and localization of disease in between eastern region and present study. We believe that further studies are needed to specify allergen characteristics of Trakya region using multicenter studies, which include other cities as well.

  11. Contact dermatitis and patch testing for the allergist.

    Science.gov (United States)

    Fonacier, Luz; Noor, Irum

    2018-03-06

    Contact dermatitis (CD) is a common disease seen by allergists. Although underutilized, patch testing (PT) remains the gold standard in the diagnosis of allergic CD. It is not difficult to perform, however, the interpretation of the PT, proper classification of the results and determination of their relevance, need an appropriate level of expertise. The objective of this article is to provide a review of CD and its key allergens and provide updates and recommendations for the practicing allergist. Through the use of various scientific search engines (e.g., PubMed and Medline) we reviewed literature on CD, PT, key allergens, occupational dermatitis and treatment. Studies on CD, important allergens, and PT were considered. Contact induced dermatitis may be due to allergic CD, irritant CD, systemic CD, contact urticaria and protein CD. Key allergens include metals (nickel, gold), topical medicaments (topical corticosteroids), and cosmetics and personal care products (fragrances and preservatives such as methyl- and methylchloro-isothiazolinone). Present relevance of a positive PT is the combination of definite, probable, and possible relevance and should be correlated with the patient's history and physical examination. Treatment of allergic CD includes identification of relevant allergens, patient education, avoidance and provision of alternative products the patient can use. CD is a common inflammatory skin disease and should be suspected in patients presenting acute, subacute or chronic dermatitis. The gold standard for diagnosing allergic CD is PT. This article provides practical recommendations for the diagnosis and management of CD commonly seen by the allergist in their practice. Copyright © 2018. Published by Elsevier Inc.

  12. The Association of Race/Ethnicity and Patch Test Results: North American Contact Dermatitis Group, 1998-2006.

    Science.gov (United States)

    Deleo, Vincent Anthony; Alexis, Andrew; Warshaw, Erin M; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel; Zug, Kathryn A; Belsito, Donald V; Fowler, Joseph F; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Rietschel, Robert L; Storrs, Frances J; Taylor, James S; Zirwas, Matthew

    2016-01-01

    The North American Contact Dermatitis Group patch tests patients with suspected allergic contact dermatitis (ACD) to a broad series of screening allergens and publishes periodic reports. We have previously reported on the association of race and ethnicity with the rates of positive responses to standard patch test allergens. This report extends those observations. The aim of the study was to report the North American Contact Dermatitis Group patch testing results from January 1, 1998, to December 31, 2006, comparing the frequency of positive reactions between white and black subjects. Standardized patch testing with 45 allergens was used at 13 centers in North America. χ analysis of results in black subjects as compared with whites was examined. A total of 19,457 patients were tested; 92.9% (17,803) were white and 7.1% (1,360) were black. The final diagnoses of ACD (whites, 45.9%; blacks, 43.6%) and irritant contact dermatitis (13.0%/13.3%) were similar in the 2 groups. The diagnosis of atopic dermatitis was less common in the white patients (8.9%) as compared with the black patients (13.3%). Positive patch test reactions rates were similar for most allergens. However, statistically, blacks reacted more frequently to p-phenylenediamine (7.0% vs 4.4%, P < 0.001), bacitracin (11.6% vs 8.3%, P = 0.0004), as well as specific rubber accelerators mercaptobenzothiazole (2.7% vs 1.8%), thiuram (6.2% vs 4.3%), and mercapto mix (1.9% vs 0.8%, P < 0.001). Whites had an increase in positive reactions to fragrances (12.12% vs 6.77%, P < 0.0001), formaldehyde (9.25% vs 5.45%, P < 0.0001), and some formaldehyde releaser preservatives used in personal care products and textile resins (9.80% vs 6.18%, P < 0.0001). There were statistically different rates of positive patch test reactions to specific allergens between black and white patients suspected of having ACD. The etiology of these differences is unclear but probably relates to culturally determined exposure patterns rather

  13. Result of standard patch test in patients suspected of having allergic contact dermatitis.

    Science.gov (United States)

    Wongpiyabovorn, Jongkonnee; Puvabanditsin, Porntip

    2005-09-01

    Contact dermatitis is a common skin disease. Disease was diagnosed by a history of contact substance together with geographic distribution of lesion. Up till now, standard patch test is one of the most reliable test to identify and confirm causative agent of allergic contact dermatitis. To determine the rate of positive standard patch test and to identify the common allergen of contact dermatitis in Thailand, we performed the standard patch test in 129 patients, suspected having allergic contact dermatitis at Department of Dermatology, King Chulalongkorn Memorial Hospital, Thailand from June 1, 2003 to September 1, 2004. The rate of positive standard patch test is 59.7% (n = 77/129). The most 3 common positive allergens were nickel sulfate (18.60%), cobalt chloride (17.05%) and fragrance mix (14.73%), respectively. The chance of positive standard patch test significantly correlated with sex (woman), initial diagnosis as contact dermatitis and history of house-worker (p = 0.017, p = 0.005 and p = 0.023, respectively). Whereas, there were no significant correlation between the chance of positive standard patch test and age of patient, location of lesion, history of recurrence, history of atopy, history of drug and food allergy. In addition, history of metal allergy significantly correlated with the chance of positive nickel sulfate or cobalt chloride in standard patch test (p = 0.017). In conclusion, this study demonstrated the prevalence of causative allergen of contact dermatitis in Thai patients using that standard patch test. Moreover, our data shown that the chance positive standard patch test was greater in patient, who were women or initial diagnosed as contact dermatitis or had history of houseworker or history of metal allergy.

  14. Different concentrations and volumes of p-phenylenediamine in pet. (equivalent doses) are associated with similar patch test outcomes

    DEFF Research Database (Denmark)

    Andersen, Flemming; Hamann, Carsten R; Andersen, Klaus E

    2018-01-01

    BACKGROUND: Concern about causing active sensitization when patch testing is performed with p-phenylenediamine (PPD) 1% pet. has led to a recommendation to use PPD 0.3% pet. as a potentially safer preparation. However, the dose per area of allergen delivered, and hence the risk of active...... sensitization, depend on the amount dispensed into the patch test chamber, which can vary widely. OBJECTIVE: To evaluate whether patch testing with equivalent doses of different concentrations of PPD in pet. is associated with similar outcomes. METHODS: Seventeen known PPD-sensitive subjects were patch tested...... with different volumes and concentrations of PPD in pet. that deliver the same allergen dose per unit area (6 mg of PPD 1% pet. and 20 mg of PPD 0.3% pet. in Finn Chambers®, both equivalent to ∼ 0.09 mg/cm2 ). RESULTS: Eleven patients (65%) had positive reactions to both doses; 4 patients (24%) had negative...

  15. Multicenter Patch Testing With Methylchloroisothizoline/Methylisothiazolinone in 100 and 200 ppm Within the International Contact Dermatitis Research Group.

    Science.gov (United States)

    Engfeldt, Malin; Ale, Iris; Andersen, Klaus E; Elsner, Peter; Goh, Chee-Leok; Goossens, An; Jerajani, Hemangi; Matsunaga, Kayoko; Bruze, Magnus

    The preservative methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) is a well-known contact sensitizer. Historically, there have been different opinions on the optimal patch test concentration of MCI/MI, and both 0.01% and 0.02% aqueous (aq.) have been proposed. In 2011, based on literature reviews, it was recommended that the concentration of 0.02% aq. should be used in the international baseline series. The aim of this study was to verify the recommendation from 2011 by comparing the patch test results from consecutive patch testing with MCI/MI 0.01% and 0.02% in clinics representing countries around the world. Two thousand seven hundred three consecutive patients with dermatitis in 8 dermatology clinics representing 8 countries were patch tested with MCI/MI 0.01% aq. and, in parallel with MCI/MI 0.02% aq., provisionally included in the baseline series. Contact allergy to MCI/MI at 0.01% and 0.02% was found in 3.7% and 5.6% of the patients, respectively (P contact allergy than 0.01% (dose, 3 μg/cm), without resulting in more adverse reactions. Methylchloroisothiazolinone/MI at 0.02% aq. should therefore be continuously used in the international baseline series.

  16. Patch testing with uranyl acetate in veterans exposed to depleted uranium during the 1991 Gulf war and the Iraqi conflict.

    Science.gov (United States)

    Shvartsbeyn, Marianna; Tuchinda, Papapit; Gaitens, Joanna; Squibb, Katherine S; McDiarmid, Melissa A; Gaspari, Anthony A

    2011-01-01

    The Depleted Uranium Follow-Up Program is a clinical surveillance program run by the Baltimore Veterans Affairs Medical Center since 1993 for veterans of the Gulf and Iraqi wars who were exposed to depleted uranium (DU) as a result of "friendly-fire" incidents. In 2009, 40 veterans from this cohort were screened for skin reactivity to metals by patch-testing with extended metal series and uranyl acetate (0.25%, 2.5%, and 25%). A control arm comprised 46 patients without any known occupational exposures to DU who were seen at the University of Maryland Dermatology Clinic for evaluation of allergic contact dermatitis. Excluding irritant reactions, no patch-test reactions to uranyl acetate were observed in the participants. Irritant reactions to DU were more common in the clinic cohort, likely reflective of the demographic differences between the two arms of the study. Biologic monitoring of urine uranium concentrations in the DU program participants with 24-hour urine samples showed evidence of percutaneous uranium absorption from the skin patches. We conclude that dermatitis observed in a subset of the veterans was unrelated to their military DU exposure. Our data suggest that future studies of skin testing with uranyl acetate should utilize 0.25%, the least irritating concentration.

  17. Stability of selected volatile contact allergens in different patch test chambers under different storage conditions

    DEFF Research Database (Denmark)

    Mose, Kristian Fredløv; Andersen, Klaus Ejner; Christensen, Lars Porskjaer

    2012-01-01

    Background. Patch test preparations of volatile substances may evaporate during storage, thereby giving rise to reduced patch test concentrations. Objectives. To investigate the stability of selected acrylates/methacrylates and fragrance allergens in three different test chambers under different...... both storage conditions, whereas MMA and 2-HPA required cool storage for maintenance of the limit. Conclusion. The Van der Bend® transport container was the best device for storage of samples of volatile contact allergens....

  18. Environmental contact factors in eczema and the results of patch testing Chinese patients with a modified European standard series of allergens.

    Science.gov (United States)

    Li, Lin-Feng; Guo, Jing; Wang, Jing

    2004-07-01

    Environmental contact factors in eczema were investigated in China by clinical questionnaire and patch testing patients with a modified European standard series of allergens. 217 consecutive eczema patients were studied. Contact dermatitis (CD) was clinically diagnosed in 30% of the patients. Among the patients patch tested, 46 patients had clinically diagnosed allergic CD (ACD), 20 patients clinically had non-ACD (NACD) (including 16 cases of irritant contact dermatitis, 1 case of phototoxic contact reaction and 3 cases of asteatotic eczema) and 115 patients had clinically suspected ACD. 45 patients (98%) in the ACD group went on to have relevant patch test results. The most common ACD was from metals, fragrance materials, cosmetics and rubber materials. The most common contact allergens identified were nickel, fragrance mix, para-phenylenediamine (PPD), carba mix and thimerosal. No adverse reactions were observed to patch testing, except for pruritus in patch-test-positive patients. The positive rate of patch testing in ACD was much higher than that in NACD (98% versus 15%, P China.

  19. Evaluation and Management of Patch Test-Negative Patients With Generalized Dermatitis.

    Science.gov (United States)

    Spiker, Alison; Mowad, Christen M

    Patients with generalized dermatitis are common in dermatology practices. Allergic contact dermatitis is often suspected, and patients frequently undergo patch testing. When the patch testing result is negative, further evaluation and management of these patients are challenging. The purpose of this study was to survey members of the American Contact Dermatitis Society regarding the evaluation and management of patch test-negative patients with generalized dermatitis. Generalized dermatitis was the most common term identified for patch test-negative patients with diffuse dermatitis. After having negative expanded patch testing results, most physicians proceeded with additional testing including skin biopsy, complete blood cell count with differential, and liver and renal function tests. The most commonly used systemic treatment is prednisone, followed by methotrexate. Narrow-band ultraviolet B (UVB) is the most commonly used light source. Antihistamines are frequently prescribed. Food allergy is not felt to be causative. This cohort of patients experiences significant impairment in quality of life, stress on personal relationships, and time off work. The management of patch test-negative patients with generalized dermatitis is challenging. This study provides insight into management of these complex patients. It also demonstrates practice gaps in the management of these patients, indicating a need for further studies to direct the evaluation and management of this patient population.

  20. EX1101: Ship Shakedown and Patch Tests on NOAA Ship Okeanos Explorer (EM302)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project will involve the shakedown of all Okeanos Explorer ship capabilities and a patch test of the Kongsberg EM302 multibeam system. Operations for this...

  1. North American contact dermatitis group patch test results: 2011-2012.

    Science.gov (United States)

    Warshaw, Erin M; Maibach, Howard I; Taylor, James S; Sasseville, Denis; DeKoven, Joel G; Zirwas, Matthew J; Fransway, Anthony F; Mathias, C G Toby; Zug, Kathryn A; DeLeo, Vincent A; Fowler, Joseph F; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Belsito, Donald V

    2015-01-01

    Patch testing is an important diagnostic tool for assessment of allergic contact dermatitis (ACD). This study documents the North American Contact Dermatitis Group (NACDG) patch-testing results from January 1, 2011, to December 31, 2012. At 12 centers in North America, patients were tested in a standardized manner with a series of 70 allergens. Data were manually verified and entered into a central database. Descriptive frequencies were calculated, and trends analyzed using χ statistics. Four thousand two hundred thirty-eight patients were tested; of these, 2705 patients (63.8%) had at least 1 positive reaction, and 2029 (48.0%) were ultimately determined to have a primary diagnosis of ACD. Four hundred eight patients (9.6%) had occupationally related skin disease. There were 7532 positive allergic reactions. As compared with previous reporting periods (2009-2010 and 2000-2010), positive reaction rates statistically increased for 6 allergens: methylchloroisothiazolinone/methylisothiazolinone (5.0%; risk ratios [RRs]: 2.01 [1.60-2.52], 1.87 [1.61-2.18]), lanolin alcohol (4.6%; RRs 1.83 [1.45-2.30], 2.10 [1.79-2.47]), cinnamic aldehyde (3.9%; 1.69 [1.32-2.15], 1.53 [1.28-1.82]), glutaral (1.5%; 1.67 [1.13-2.48], 1.31 [1.00-1.71]), paraben mix (1.4%; 1.77 [1.16-2.69], 1.44 [1.09-1.92]), and fragrance mix I (12.1%; RRs 1.42 [1.25-1.61], 1.24 [1.14-1.36]). Compared with the previous decade, positivity rates for all formaldehyde-releasing preservatives significantly decreased (formaldehyde 6.6%; RR, 0.82 [0.73, 0.93]; quaternium-15 6.4% RR 0.75 [0.66, 0.85]; diazolidinyl urea 2.1%; RR, 0.67 [0.54, 0.84]; imidazolidinyl urea 1.6%, 0.60 [0.47, 0.77]; bronopol 1.6%; RR, 0.60 [0.46, 0.77]; DMDM hydantoin 1.6%; RR, 0.59 [0.54, 0.84]). Approximately a quarter of patients had at least 1 relevant allergic reaction to a non-NACDG allergen. In addition, approximately one-fourth to one-third of reactions detected by NACDG allergens would have been hypothetically missed by T

  2. Recommendation to include fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) in the European baseline patch test series.

    Science.gov (United States)

    Bruze, Magnus; Andersen, Klaus Ejner; Goossens, An

    2008-03-01

    The currently used fragrance mix in the European baseline patch test series (baseline series) fails to detect a substantial number of clinically relevant fragrance allergies. To investigate whether it is justified to include hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) and fragrance mix 2 containing hydroxyisohexyl 3-cyclohexene carboxaldehyde, citral, farnesol, coumarin, citronellol, and alpha-hexyl cinnamal in the European baseline patch test series. Survey of the literature on reported frequencies of contact allergy and allergic contact dermatitis from fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) as well as reported results of experimental provocation test. Fragrance mix 2 has been demonstrated to be a useful additional marker of fragrance allergy with contact allergy rates up to 5% when included in various national baseline patch test series. Of the fragrance substances present in fragrance mix 2, hydroxyisohexyl 3-cyclohexene carboxaldehyde is the most common sensitizer. Contact allergy rates between 1.5% and 3% have been reported for hydroxyisohexyl 3-cyclohexene carboxaldehyde in petrolatum (pet.) at 5% from various European centres when tested in consecutive dermatitis patients. From 2008, pet. preparations of fragrance mix 2 at 14% w/w (5.6 mg/cm(2)) and hydroxyisohexyl 3-cyclohexene carboxaldehyde at 5% w/w (2.0 mg/cm(2)) are recommended for inclusion in the baseline series. With the Finn Chamber technique, a dose of 20 mg pet. preparation is recommended. Whenever there is a positive reaction to fragrance mix 2, additional patch testing with the 6 ingredients, 5 if there are simultaneous positive reactions to hydroxyisohexyl 3-cyclohexene carboxaldehyde and fragrance mix 2, is recommended.

  3. Multicenter Patch Testing With a Resol Resin Based on Phenol and Formaldehyde Within the International Contact Dermatitis Research Group

    DEFF Research Database (Denmark)

    Isaksson, M.; Ale, I.; Andersen, Klaus Ejner

    2015-01-01

    Background Contact allergy to phenol-formaldehyde resins (PFRs) based on phenol and formaldehyde is not detected by a p-tertiary-butylphenol-formaldehyde resin included in most baseline patch test series. Objective The aims of this study were to investigate the contact allergy rate to PFR-2.......2%) reacted to PFR-2. Of those 28 individuals, one had a positive reaction to formaldehyde and 2 to p-tertiary-butylphenol-formaldehyde resin. Simultaneous allergic reactions were noted to colophonium in 3, to Myroxylon pereirae in 5, and to fragrance mix I in 8. Conclusions The contact allergy frequency...

  4. Patch testing with a new fragrance mix - reactivity to the individual constituents and chemical detection in relevant cosmetic products

    DEFF Research Database (Denmark)

    Frosch, Peter J; Rastogi, Suresh C; Pirker, Claudia

    2005-01-01

    order was the same for both FM II concentrations: hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) > citral > farnesol > citronellol > alpha-hexyl-cinnamic aldehyde (AHCA). No unequivocally positive reaction to coumarin was observed. Lyral) was the dominant individual constituent, with positive...... and a positive reaction to either 28% or 14% FM II but a negative reaction to FM I. Analysis with GC-MS in a total of 24 products obtained from 12 patients showed at least 1-5 individual constituents per product: Lyral (79.2%), citronellol (87.5%), AHCA (58.3%), citral (50%) and coumarin (50%). The patients were...... patch test positive to Lyral, citral and AHCA. In conclusion, patients with a certain fragrance history and a negative reaction to FM I can be identified by FM II. Testing with individual constituents is positive in about 50% of cases reacting to either 14% or 28% FM II....

  5. Multicenter Patch Testing With a Resol Resin Based on Phenol and Formaldehyde Within the International Contact Dermatitis Research Group.

    Science.gov (United States)

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus; Diepgen, Thomas; Elsner, Peter; Goossens, An; Goh, Chee-Leok; Jerajani, Hemangi; Maibach, Howard; Matsunaga, Kayoko; McFadden, John; Nixon, Rosemary; Sasseville, Denis; Bruze, Magnus

    2015-01-01

    Contact allergy to phenol-formaldehyde resins (PFRs) based on phenol and formaldehyde is not detected by a p-tertiary-butylphenol-formaldehyde resin included in most baseline patch test series. The aims of this study were to investigate the contact allergy rate to PFR-2 in an international population and to investigate associated simultaneous allergic reactions. Thirteen centers representing the International Contact Dermatitis Research Group included PFR-2 into their patch test baseline series during a period of 6 months in 2012. Of 2259 patients tested, 28 (1.2%) reacted to PFR-2. Of those 28 individuals, one had a positive reaction to formaldehyde and 2 to p-tertiary-butylphenol-formaldehyde resin. Simultaneous allergic reactions were noted to colophonium in 3, to Myroxylon pereirae in 5, and to fragrance mix I in 8. The contact allergy frequency in the tested population (1.2%) merits its inclusion into the international baseline series and possibly also into other baseline series after appropriate investigations. Significantly, overrepresented simultaneous allergic reactions were noted for M. pereirae and fragrance mix I.

  6. Patch and Prick Tests in Hand Eczema: Results of A Sixty Seven Patient Series

    Directory of Open Access Journals (Sweden)

    Bilge Fettahlıoğlu Karaman

    2017-12-01

    Full Text Available Objective: The patch and prick tests have a place in the management of patients with hand eczema. In this study, we investigated whether some of the clinical features patients with hand eczema could provide us with the predictability of skin test results. Methods: In Çukurova University Faculty of Medicine, 67 consecutive patients with hand eczema; evaluated in terms of duration of disease, morphology and severity. All of the patients were undergoes patch tested with the European Standard Series, and needle testing with routine aeroallergens. Results: Patch test with at least one allergen was positive in 46.3% of the patients; wheras this rate was 23.9% for prick test. The likelihood of having a contact sensitivity of patients complaining of hand eczema for at least three years was statistically more significant [odds ratio (OR 0.9]. Although statistically not significant, it is less likely to be sensitized to patients with keratotic and/or licheniform hand eczema (OR 0.3. The severity of hand eczema was not predictive of patch test, there was no indicator of needle test positivity. Conclusion: We strongly recommend patch testing in all patients with prolonged hand eczema.

  7. Increased retest reactivity by both patch and use test with methyldibromoglutaronitrile in sensitized individuals

    DEFF Research Database (Denmark)

    Jensen, Charlotte D; Johansen, Jeanne Duus; Menné, Torkil

    2006-01-01

    -exposure by both a patch test challenge and a use test with a liquid soap preserved with MDBGN. MDBGN dermatitis was elicited on the back and arms of sensitized individuals. One month later the previously eczematous areas were challenged with MDBGN. On the back, the test sites were patch-tested with a serial...... dilution of MDBGN and a use test was performed on the arms with an MDBGN-containing soap. A statistically significant increased response was seen on the areas with previous dermatitis on the back. Eight of the nine patients who developed dermatitis on the arms from the MDBGN-containing soap had...

  8. Atopy patch tests in young adult patients with atopic dermatitis and controls: dose-response relationship, objective reading, reproducibility and clinical interpretation.

    Science.gov (United States)

    Bygum, Anette; Mortz, Charlotte Gotthard; Andersen, Klaus Ejner

    2003-01-01

    The clinical interpretation and reproducibility of atopy patch tests was studied in 23 selected young adult patients with atopic dermatitis and 25 healthy controls using standard inhalant allergens. Non-invasive measurements were used for objective assessment of test reactions and the participants were retested after 6 weeks. Ten of 19 (53%) evaluable patients with atopic dermatitis had at least one positive atopy patch test. However, there was no clear clinical relevance of the atopy patch test results when related to patient history and distribution of dermatitis. Reproducible and dose-dependent results were obtained with Dermatophagoides pteronyssinus, grass and cat with a reproducibility rate of 0.69 to 0.81 in patients and 0.60-0.96 in controls. A unique finding was a significant positive correlation between a positive atopy patch test, allergen dose and increase in transepidermal water loss and erythema, while measurement of capacitance did not distinguish between positive and negative reactions. The results of the present study do not support the routine use of atopy patch tests in the evaluation of adult patients with atopic dermatitis.

  9. Photo-patch and patch tests in patients with dermatitis over the photo-exposed areas: A study of 101 cases from a tertiary care centre in India.

    Science.gov (United States)

    Sharma, Vinod Kumar; Bhari, Neetu; Wadhwani, Ashok Roopchand; Bhatia, Riti

    2018-02-01

    Many patients with dermatitis over photo-exposed body areas are positive to many contact allergens and have a pre-existing allergic contact dermatitis. This study included patients who presented to a tertiary centre in India with dermatitis on photo-exposed body areas suspected of chronic actinic dermatitis. Their detailed histories were recorded and cutaneous and systemic examinations were performed. Patch testing was done in all the patients and photo-patch testing was carried out in 86 patients. Altogether 101 patients were included (69 males, 32 females). The most common presentation was lichenified hyperpigmented plaques on the photo-exposed sites. Photosensitivity was recorded in 64 (63%) patients and summer exacerbation in 52 (52%). Exposure to the Parthenium hysterophorus weed was recorded in 70 (69%) patients, 27 (26.7%) had a history of hair dye application and 20 (20%) had a history of atopy. Photo-patch test was positive in 11 (12.8%) patients and patch testing was positive in 71 (70%). Parthenium hysterophorus was the most common allergen implicated and was positive in three (4%) photo-patch and 52 (52%) patch tests. Other positive photo-patch test allergens were perfume mix, balsam of Peru, thiuram mix, Compositae mix and promethazine hydrochloride. Other common patch test allergens were parthenolide, colophony, fragrance mix and p-phenylenediamine (PPD) base. In the Indian population parthenium and perfume mix are the most common photoallergens in patients with dermatitis over photo-exposed areas, while parthenium, colophony, fragrance mix and PPD are the common positive allergens. © 2016 The Australasian College of Dermatologists.

  10. Clinical patch test data evaluated by multivariate analysis. Danish Contact Dermatitis Group

    DEFF Research Database (Denmark)

    Christophersen, J; Menné, T; Tanghøj, P

    1989-01-01

    The aim of the present study was to evaluate the influence of individual explanatory factors, such as sex, age, atopy, test time and presence of diseased skin, on clinical patch test results, by application of multivariate statistical analysis. The study population was 2166 consecutive patients...... patch tested with the standard series of the International Contact Dermatitis Research Group (ICDRG) by members of the Danish Contact Dermatitis Group (DCDG) over a period of 6 months. For the 8 test allergens most often found positive (nickel, fragrance-mix, cobalt, chromate, balsam of Peru, carba......-mix, colophony, and formaldehyde), one or more individual factors were of significance for the risk of being sensitized, except for chromate and formaldehyde. It is concluded that patch test results can be compared only after stratification of the material or by multivariate analysis....

  11. Routine patch testing with the sesquiterpene lactone mix in Europe: a 2-year experience

    DEFF Research Database (Denmark)

    Paulsen, E; Andersen, Klaus Ejner; Brandão, F M

    1999-01-01

    To test the screening value of the sesquiterpene lactone (SL) mix in Europe today and describe epidemiological and clinical features of Compositae-sensitive patients, the SL mix 0.1% pet. was included in the standard patch test series in 11 European clinics. 10,695 patients were tested, and 106 (1...

  12. A retrospective study of 2585 patients patch tested with the European standard series in Hong Kong (1995-99).

    Science.gov (United States)

    Lam, Wai Sun; Chan, Loi Yuen; Ho, Stanley Ching Kong; Chong, Lai Yin; So, Win Han; Wong, Tze Wai

    2008-02-01

    Data on patch test findings in Hong Kong are scarce, with the last survey performed more than 10 years ago. A retrospective analysis of results from all patch tests performed on patients with suspected allergic contact dermatitis from January 1995 to December 1999 in the Social Hygiene Service, which provides a public dermatology service in Hong Kong, was undertaken. We aimed to explore the demographic data associated with positive reactions and the profile of contact sensitizing allergens in Hong Kong. A total of 2585 patients were patch tested with the European standard series during the period. Most were Chinese, with a female-to-male ratio of 3 : 2. One or more positive responses were noted in 1415 patients (54.7%). The most common allergen was nickel sulfate (24.4%), followed by fragrance mix (13.7%), cobalt chloride (8.7%), p-phenylenediamine (6.0%), and balsam of Peru (5.7%). Nickel sensitivity was more common in female patients, and dichromate sensitivity was more common in male patients (P history were significant risk factors for nickel sensitivity. This study provides a profile of allergens responsible for allergic contact dermatitis in the public dermatology service in Hong Kong. A prospective study, using a larger panel of allergens, involving patients from both the private and public sectors, would provide a more comprehensive profile of contact allergens in Hong Kong and contribute to the establishment of a local standard series.

  13. Standardization of the TRUE Test imidazolidinyl urea and diazolidinyl urea patches

    DEFF Research Database (Denmark)

    Agner, T; Andersen, Klaus Ejner; Björkner, B

    2001-01-01

    The preservatives imidazolidinyl urea (IMID, Germall 115) and diazolidinyl urea (DU, Germall II) are commonly used in cosmetic products and are well-known sensitizers. The aim of the present study was to establish the optimal patch test concentration in hydrophilic dried-in vehicle (TRUE Test...

  14. An 8-year experience with routine SL mix patch testing supplemented with Compositae mix in Denmark

    DEFF Research Database (Denmark)

    Paulsen, E; Andersen, Klaus Ejner; Hausen, B M

    2001-01-01

    Routine patch testing with sesquiterpene lactone (SL) mix, supplemented with Compositae mix (CM) and other Compositae extracts and allergens where appropriate, was evaluated over an 8-year period. 190 of 4386 patients tested (4.3%) were Compositae-sensitive, 143 females (mean age 51.5 years) and ...

  15. EAACI Position Paper for practical patch testing in Allergic Contact Dermatitis in children

    DEFF Research Database (Denmark)

    de Waard-van der Spek, Flora B; Darsow, Ulf; Mortz, Charlotte G

    2015-01-01

    Allergic Contact Dermatitis (ACD) in children appears to be on the increase, and contact sensitization may already begin in infancy. The diagnosis of contact dermatitis requires a careful evaluation of a patient's clinical history, physical examination and skin testing. Patch testing is the gold...

  16. A localized flare of dermatitis may render patch tests uninterpretable in some patients with recently controlled widespread dermatitis.

    Science.gov (United States)

    Magembe, Anna J; Davis, Mark D P; Richardson, Donna M

    2009-01-01

    Patch testing rarely is confounded by localized dermatitis induced in the area being tested (usually the back). Its occurrence renders the interpretation of patch tests impossible. To review our experience of the circumstances in which this phenomenon occurs during patch testing. We retrospectively reviewed patients with this phenomenon who underwent patch testing from January 1, 2002, through June 30, 2006. Of the 3,569 patients tested, 12 (0.34% [9 men and 3 women]) had development of this phenomenon. All patients previously had recent widespread dermatitis that was suppressed temporarily with topical corticosteroids and wet dressings at the time of patch testing. The period between control of the dermatitis and the initiation of patch testing was less than 1 week for all patients. Three patients (25%) had recently discontinued therapy with systemic corticosteroids (less than 1 week earlier). In patients with irritable skin either immediately after widespread dermatitis is controlled or after the cessation of systemic corticosteroid treatment, a flare of dermatitis induced by patch testing may render patch tests unreadable and therefore uninterpretable. To avoid this confounding occurrence, a waiting period between control of widespread dermatitis and initiation of patch testing is advised.

  17. EAACI position paper for practical patch testing in allergic contact dermatitis in children.

    Science.gov (United States)

    de Waard-van der Spek, Flora B; Darsow, Ulf; Mortz, Charlotte G; Orton, David; Worm, Margitta; Muraro, Antonella; Schmid-Grendelmeier, Peter; Grimalt, Ramon; Spiewak, Radoslaw; Rudzeviciene, Odilija; Flohr, Carsten; Halken, Susanne; Fiocchi, Alessandro; Borrego, Luis Miguel; Oranje, Arnold P

    2015-11-01

    Allergic contact dermatitis (ACD) in children appears to be on the increase, and contact sensitization may already begin in infancy. The diagnosis of contact dermatitis requires a careful evaluation of a patient's clinical history, physical examination, and skin testing. Patch testing is the gold standard diagnostic test. Based on consensus, the EAACI Task Force on Allergic Contact Dermatitis in Children produced this document to provide details on clinical aspects, the standardization of patch test methodology, and suggestions for future research in the field. We provide a baseline list of test allergens to be tested in children with suspected ACD. Additional tests should be performed only on specific indications. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Course of Skin Symptoms and Quality of Life in Children Referred for Patch Testing

    DEFF Research Database (Denmark)

    Simonsen, Anne B; Sommerlund, Mette; Deleuran, Mette

    2015-01-01

    Children are patch tested in the same manner as adults, but little has been done to establish whether positive or negative findings influence the course of skin symptoms. To uncover the course of skin symptoms and the impact of persistent eczema on life quality in paediatric patients referred...... to follow-up. Among patients without atopic dermatitis, 23.5% reported to suffer from chronic eczema. Persistent eczema increased the risk of severe impairment of life quality. Our findings indicate a significant risk of childhood eczema becoming chronic and affecting life quality considerably. Patch...

  19. The dose-response relationship between the patch test and ROAT and the potential use for regulatory purposes

    DEFF Research Database (Denmark)

    Fischer, Louise Arup; Voelund, Aage; Andersen, Klaus Ejner

    2009-01-01

    Background: Allergic contact dermatitis is common and can be prevented. The relationship between thresholds for patch tests and the repeated open application test (ROAT) is unclear. It would be desirable if patch test and ROAT data from already sensitized individuals could be used in prevention. ...

  20. The optimal patch test concentration for ascaridole as a sensitizing component of tea tree oil

    NARCIS (Netherlands)

    Christoffers, Wietske Andrea; Bloemeke, Brunhilde; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise Anna

    BACKGROUND: Tea tree oil is used as a natural remedy, but is also a popular ingredient in household and cosmetic products. Oxidation of tea tree oil results in degradation products, such as ascaridole, which may cause allergic contact dermatitis. OBJECTIVES: To identify the optimal patch test

  1. EX1201: Ship Shakedown and Patch Tests on NOAA Ship Okeanos Explorer between 20100214 and 20120223

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — EX1201 is the 2012 shakedown mission of NOAA ship Okeanos Explorer (EX) and will perform system patch tests of the vessel’s Kongsberg EM302 multibeam sonar....

  2. The use of a flexible patch leaving rule under exploitative competition: a field test with swans

    NARCIS (Netherlands)

    Nolet, B.A.; Klaassen, R.H.G.; Mooij, W.M.

    2006-01-01

    Learning animals are predicted to use a flexible patch-leaving threshold (PLT) while foraging in a depletable environment under exploitative competition. This prediction was tested in flock-feeding Bewick's swans (Cygnus columbianus bewickii) depleting hidden tubers of fennel pondweed (Potamogeton

  3. European Society of Contact Dermatitis guideline for diagnostic patch testing -- recommendations on best practice

    DEFF Research Database (Denmark)

    Johansen, Jeanne D; Aalto-Korte, Kristiina; Agner, Tove

    2015-01-01

    The present guideline summarizes all aspects of patch testing for the diagnosis of contact allergy in patients suspected of suffering, or having been suffering, from allergic contact dermatitis or other delayed-type hypersensitivity skin and mucosal conditions. Sections with brief descriptions an...

  4. Patch test reactivity to feverfew-containing creams in feverfew-allergic patients

    DEFF Research Database (Denmark)

    Paulsen, Evy; Christensen, Lars P; Fretté, Xavier

    2010-01-01

    with feverfew contact allergy were patch tested with two creams containing the feverfew extract. Subsequently, the creams were analysed by liquid chromatography with tandem mass spectrometry to detect parthenolide. Results: Four of the patients tested positive to one of the creams; reactivity was associated......-sensitive patients. The reactivity may be enhanced by simultaneous testing with parthenolide, but the reactivity is lost over time, probably because of degradation of parthenolide....

  5. Recommendation to increase the test concentration of methylchloroisothiazolinone/methylisothiazolinone in the European baseline patch test series - on behalf of the European Society of Contact Dermatitis and the European Environmental and Contact Dermatitis Research Group.

    Science.gov (United States)

    Bruze, Magnus; Goossens, An; Isaksson, Marléne

    2014-07-01

    Methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) in aqua is present in the European baseline patch test series at 100 ppm, whereas 200 ppm has been used in Sweden since 1986, in Spain in the late 1980s, and, in recent years, also in the United Kingdom and Ireland. With regard to MCI/MI, to investigate the data on contact allergy rates in dermatitis patients, the frequencies of allergic contact dermatitis in the same group, and adverse reactions, particularly patch test sensitization in tested dermatitis patients, and to find the optimal patch test concentration as dose in mg/cm(2) . We performed a survey of the literature found via the National Library of Medicine (PubMed, http://www.ncbi.nlm.nih.gov/pubmed, last accessed 20 February 2014). MCI/MI at 200 ppm aq. diagnosis substantially more contact allergy and allergic contact dermatitis, without any registered increase in patch test sensitization, than the presently used concentration of 100 ppm. MCI/MI at 200 ppm aq. is recommended to be included in the European baseline patch test series. To avoid patch test sensitization, a dose of 0.006 mg/cm(2) must not be exceeded, which means a volume of 15 µl for Finn Chambers(®) (Ø 8 mm). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Patch testing with a new fragrance mix - reactivity to the individual constituents and chemical detection in relevant cosmetic products.

    Science.gov (United States)

    Frosch, Peter J; Rastogi, Suresh C; Pirker, Claudia; Brinkmeier, Thomas; Andersen, Klaus E; Bruze, Magnus; Svedman, Cecilia; Goossens, An; White, Ian R; Uter, Wolfgang; Arnau, Elena Giménez; Lepoittevin, Jean-Pierre; Johansen, Jeanne Duus; Menne, Torkil

    2005-04-01

    A new fragrance mix (FM II), with 6 frequently used chemicals not present in the currently used fragrance mix (FM I), was evaluated in 6 dermatological centres in Europe, as previously reported. In this publication, test results with the individual constituents and after repeated open application test (ROAT) of FM II are described. Furthermore, cosmetic products which had caused a contact dermatitis in patients were analysed for the presence of the individual constituents. In 1701 patients, the individual constituents of the medium (14%) and the highest (28%) concentration of FM II were simultaneously applied with the new mix at 3 concentrations (break-down testing for the lowest concentration of FM II (2.8%) was performed only if the mix was positive). ROAT was performed with the concentration of the FM II which had produced a positive or doubtful (+ or ?+) patch test reaction. Patients' products were analysed for the 6 target compounds by gas chromatography-mass spectrometry (GC-MS). 50 patients (2.9%) showed a positive reaction to 14% FM II and 70 patients (4.1%) to 28% FM II. 24/50 (48%) produced a positive reaction to 1 or more of the individual constituents of 14% FM II and 38/70 (54.3%) to 28% FM II, respectively. If doubtful reactions to individual constituents are included, the break-down testing was positive in 74% and 70%, respectively. Patients with a positive reaction to 14% FM II showed a higher rate of reactions to the individual constituent of the 28% FM II: 36/50 (72%). Positive reactions to individual constituents in patients negative to FM II were exceedingly rare. If doubtful reactions are regarded as negative, the sensitivity, specificity, positive predictive value and negative predictive value for the medium concentration of FM II towards at least 1 individual constituent was 92.3% (exact 95% confidence interval 74.9-99.1%), 98.4% (97.7-99.0%), 48% (33.7-62.6%) and 99.9% (99.6-"100.0%), respectively. For the high concentration, the figures

  7. Stability of selected volatile contact allergens in different patch test chambers under different storage conditions.

    Science.gov (United States)

    Mose, Kristian F; Andersen, Klaus E; Christensen, Lars Porskjaer

    2012-04-01

    Patch test preparations of volatile substances may evaporate during storage, thereby giving rise to reduced patch test concentrations. To investigate the stability of selected acrylates/methacrylates and fragrance allergens in three different test chambers under different storage conditions. Petrolatum samples of methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl acrylate (2-HPA), cinnamal and eugenol in patch test concentrations were stored in three different test chambers (IQ chamber™, IQ Ultimate™, and Van der Bend® transport container) at room temperature and in a refrigerator. The samples were analysed in triplicate with high-performance liquid chromatography. The decrease in concentration was substantial for all five allergens under both storage conditions in IQ chamber™ and IQ Ultimate™, with the exception of 2-HEMA during storage in the refrigerator. For these two chamber systems, the contact allergen concentration dropped below the stability limit in the following order: MMA, cinnamal, 2-HPA, eugenol, and 2-HEMA. In the Van der Bend® transport container, the contact allergens exhibited acceptable stability under both storage conditions, whereas MMA and 2-HPA required cool storage for maintenance of the limit. The Van der Bend® transport container was the best device for storage of samples of volatile contact allergens. © 2012 John Wiley & Sons A/S.

  8. Patch testing with markers of fragrance contact allergy. Do clinical tests correspond to patients' self-reported problems?

    DEFF Research Database (Denmark)

    Johansen, J D; Andersen, T F; Veien, Niels

    1997-01-01

    The aim of the present study was to investigate the relationship between patients' own recognition of skin problems using consumer products and the results of patch testing with markers of fragrance sensitization. Eight hundred and eighty-four consecutive eczema patients, 18-69 years of age, filled...

  9. Patch testing with markers of fragrance contact allergy. Do clinical tests correspond to patients' self-reported problems?

    DEFF Research Database (Denmark)

    Johansen, J D; Andersen, T F; Veien, Niels

    1997-01-01

    The aim of the present study was to investigate the relationship between patients' own recognition of skin problems using consumer products and the results of patch testing with markers of fragrance sensitization. Eight hundred and eighty-four consecutive eczema patients, 18-69 years of age, fill...

  10. Effects of time and recall of patch test results on quality of life (QoL) after testing. Cross-sectional study analyzing QoL in hand eczema patients 1, 5 and 10 years after patch testing.

    Science.gov (United States)

    Jamil, Wasim N; Lindberg, Magnus

    2017-08-01

    Patch testing can improve health-related quality of life (HRQOL). To study the impact on HRQOL of elapsed time after patch testing (1-10 years), and how the outcome of testing and patients' recall affects HRQOL. The Dermatology Life Quality Index (DLQI) questionnaire was sent to all patients (aged 18-65 years) who were patch tested for suspected contact allergy in 2009, 2005 and 2000 at the Department of Dermatology in Örebro. The response rate was 51% (n = 256). The DLQI score was significantly lower at 10 years after patch testing (mean DLQI = 5.5) than at 1 year (mean DLQI = 7.7). Work was the most impaired aspect. A binary logistic model showed that only time (10 years after testing) was associated with no effect, a light effect or a moderate effect (DLQI negative or positive test results concerning full recall, partial recall or no recall of diagnosed allergens. Although there was an improvement in HRQOL over time, the work aspect remained a major problem. The improvement was not affected by the outcome of testing and patients' recall of test results. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Adverse reactions to cosmetics and methods of testing

    Directory of Open Access Journals (Sweden)

    Nigam P

    2009-01-01

    Full Text Available Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test, eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test, mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test, and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test. Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  12. Adverse reactions to cosmetics and methods of testing.

    Science.gov (United States)

    Nigam, P K

    2009-01-01

    Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test), eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test), mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test), and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test). Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  13. EX1101: Ship Shakedown and Patch Tests on NOAA Ship Okeanos Explorer between March 16 and April 1, 2011

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project will involve the shakedown of all Okeanos Explorer ship capabilities and a patch test of the Kongsberg EM302 multibeam system. Operations for this...

  14. Chloromethylisothiazolone/methylisothiazolone (CMI/MI) use test with a shampoo on patch-test-positive subjects. Results of a multicentre double-blind crossover trial

    DEFF Research Database (Denmark)

    Frosch, P J; Lahti, A; Hannuksela, M

    1995-01-01

    A randomized, multicentre, double-blind, 2-period crossover study with 2 shampoos was performed on subjects patch-test-positive to 100 ppm CMI/MI. One shampoo was preserved with 15 ppm a.i. CMI/MI, the other with 0.3% imidazolidinyl urea (IU). 27 subjects from 5 European dermatology clinics...... participated. 1 subject discontinued use after severe adverse reactions to the CMI/MI-preserved shampoo and did not evaluate the other shampoo. Another 2 subjects developed moderate symptoms with the CMI/MI-preserved shampoo and discontinued its use, but tolerated the IU-preserved shampoo for the full 2-week...... period. 2 subjects discontinued use after 1 or 2 washes after severe adverse reactions to the IU-preserved shampoo. 1 of these subjects tolerated the CMI/MI-preserved shampoo for 2 weeks without any untoward effects. However, the majority of subjects had negative findings on the scalp, face, neck...

  15. Patch testers' opinions regarding diagnostic criteria for metal hypersensitivity reactions to metallic implants

    DEFF Research Database (Denmark)

    Schalock, Peter C; Thyssen, Jacob P

    2013-01-01

    Metal hypersensitivity reactions to implanted devices remain a challenging and controversial topic. Diagnostic criteria and methods are not well delineated.......Metal hypersensitivity reactions to implanted devices remain a challenging and controversial topic. Diagnostic criteria and methods are not well delineated....

  16. Patch testing to a textile dye mix by the international contact dermatitis research group.

    Science.gov (United States)

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus E; Diepgen, Thomas; Goh, Chee-Leok; Goossens R, An; Jerajani, Hemangi; Maibach, Howard I; Sasseville, Denis; Bruze, Magnus

    2015-01-01

    Disperse dyes are well-known contact sensitizers not included in the majority of commercially available baseline series. To investigate the outcome of patch testing to a textile dye mix (TDM) consisting of 8 disperse dyes. Two thousand four hundred ninety-three consecutive dermatitis patients in 9 dermatology clinics were patch tested with a TDM 6.6%, consisting of Disperse (D) Blue 35, D Yellow 3, D Orange 1 and 3, D Red 1 and 17, all 1.0% each, and D Blue 106 and D Blue 124, each 0.3%. 90 reacted positively to the TDM. About 92.2% of the patients allergic to the TDM were also tested with the 8 separate dyes. Contact allergy to TDM was found in 3.6% (1.3-18.2) Simultaneous reactivity to p-phenylenediamine was found in 61.1% of the TDM-positive patients. Contact allergy to TDM and not to other p-amino-substituted sensitizers was diagnosed in 1.2%. The most frequent dye allergen in the TDM-positive patients was D Orange 3. Over 30% of the TDM allergic patients had been missed if only the international baseline series was tested. Contact allergy to TDM could explain or contribute to dermatitis in over 20% of the patients. Textile dye mix should be considered for inclusion into the international baseline series.

  17. Patch testing with a new fragrance mix detects additional patients sensitive to perfumes and missed by the current fragrance mix.

    Science.gov (United States)

    Frosch, Peter J; Pirker, Claudia; Rastogi, Suresh C; Andersen, Klaus E; Bruze, Magnus; Svedman, Cecilia; Goossens, An; White, Ian R; Uter, Wolfgang; Arnau, Elena Giménez; Lepoittevin, Jean-Pierre; Menné, Torkil; Johansen, Jeanne Duus

    2005-04-01

    The currently used 8% fragrance mix (FM I) does not identify all patients with a positive history of adverse reactions to fragrances. A new FM II with 6 frequently used chemicals was evaluated in 1701 consecutive patients patch tested in 6 dermatological centres in Europe. FM II was tested in 3 concentrations - 28% FM II contained 5% hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral), 2% citral, 5% farnesol, 5% coumarin, 1% citronellol and 10%alpha-hexyl-cinnamic aldehyde; in 14% FM II, the single constituents' concentration was lowered to 50% and in 2.8% FM II to 10%. Each patient was classified regarding a history of adverse reactions to fragrances: certain, probable, questionable, none. Positive reactions to FM I occurred in 6.5% of the patients. Positive reactions to FM II were dose-dependent and increased from 1.3% (2.8% FM II), through 2.9% (14% FM II) to 4.1% (28% FM II). Reactions classified as doubtful or irritant varied considerably between the 6 centres, with a mean value of 7.2% for FM I and means ranging from 1.8% to 10.6% for FM II. 8.7% of the tested patients had a certain fragrance history. Of these, 25.2% were positive to FM I; reactivity to FM II was again dose-dependent and ranged from 8.1% to 17.6% in this subgroup. Comparing 2 groups of history - certain and none - values for sensitivity and specificity were calculated: sensitivity: FM I, 25.2%; 2.8% FM II, 8.1%; 14% FM II, 13.5%; 28% FM II, 17.6%; specificity: FM I, 96.5%; 2.8% FM II, 99.5%; 14% FM II, 98.8%; 28% FM II, 98.1%. 31/70 patients (44.3%) positive to 28% FM II were negative to FM I, with 14% FM II this proportion being 16/50 (32%). In the group of patients with a certain history, a total of 7 patients were found reacting to FM II only. Conversely, in the group of patients without any fragrance history, there were significantly more positive reactions to FM I than to any concentration of FM II. In conclusion, the new FM II detects additional patients sensitive to fragrances missed

  18. Patch test concentrations (doses in mg/cm(2) ) for the 12 non-mix fragrance substances regulated by European legislation

    DEFF Research Database (Denmark)

    Bruze, Magnus; Svedman, Cecilia; Andersen, Klaus Ejner

    2012-01-01

    Background. According to EU legislation, 26 fragrance substance allergens must be labelled on cosmetic products. For 12 of them, the optimal patch test concentration/dose has not been evaluated. Objectives. To establish the optimal patch test doses in mg/cm(2) for the 12 fragrance substances......, it is recommended that half of the maximum patch test dose (mg/cm(2) ) be used for aimed and screening patch testing....... that are not included in fragrance mix I or II in the European baseline patch test series. Materials and Methods. Patch testing with the 12 fragrance substances was performed in a stepwise manner encompassing up to five rounds in at least 100 dermatitis patients for each round. Before patch testing, an individual...

  19. Acute generalized exanthematous pustulosis caused by morphine, confirmed by positive patch test and lymphocyte transformation test

    NARCIS (Netherlands)

    Kardaun, Sylvia H.; de Monchy, Jan G.

    Morphine, an opium alkaloid, frequently causes side effects such as hyperhidrosis and facial flushing, but serious cutaneous adverse drug reactions are seldom observed. Best known are Urticaria, erythema, and pruritus; sometimes pseudoallergic anaphylactoid reactions, and blisters are reported.

  20. Patch testing with fragrances: results of a multicenter study of the European Environmental and Contact Dermatitis Research Group with 48 frequently used constituents of perfumes.

    Science.gov (United States)

    Frosch, P J; Pilz, B; Andersen, K E; Burrows, D; Camarasa, J G; Dooms-Goossens, A; Ducombs, G; Fuchs, T; Hannuksela, M; Lachapelle, J M

    1995-11-01

    The objective of this study was to determine the frequency of reactivity to a series of commonly used fragrances in dermatological patients. A total of 48 fragrances (FF) were chosen, based on the publication of Fenn in 1989 in which the top 25 constituents of 3 types (1. perfumes, 2. household products, 3. soaps) of 400 commercial products on the US market had been determined. In a pilot study on a total of 1069 patients in 11 centres, the appropriate test concentration and vehicle were examined. For most fragrances, 1% and 5% were chosen, and petrolatum proved to be the best vehicle in comparison to isopropyl myristate and diethyl phthalate. In the main study, a set of 5 to 10 fragrances at 2 concentrations was patch tested in each centre on a minimum of 100 consecutive patients seen in the patch test clinic. These patients were also patch tested to a standard series with the 8% fragrance mix (FM) and its 8 constituents. In patients with a positive reaction to any of the 48 FF, a careful history with regard to past or present reactions to perfumed products was taken. A total of 1323 patients were tested in 11 centres. The 8% FM was positive in 89 patients (8.3% of 1072 patients). Allergic reactions to the constituents were most frequent to oak moss (24), isoeugenol (20), eugenol (13), cinnamic aldehyde (10) and geraniol (8). Reactions read as allergic on day 3/4 were observed only 10X to 7 materials of the new series (Iso E Super (2), Lyral (3), Cyclacet (1), DMBCA (1), Vertofix (1), citronellol (1) and amyl salicylate (1)). The remaining 41 fragrances were negative. 28 irritant or doubtful reactions on day 3/4 were observed to a total of 19 FF materials (more than 1 reaction: 5% citronellol (2), 1% amyl salicylate (2), 1% isononyl acetate (3), 0.1% musk xylol (2), 1% citral (2), and 1% ionone beta (2)). Clinical relevance of positive reactions to any of the FF series was not proved in a single case. This included the 4 reactions in patients who were negative to

  1. Occupational Contact Dermatitis: Workers' Compensation Patch Test Results of Portland, Oregon, 2005-2014.

    Science.gov (United States)

    Coman, Garrett; Zinsmeister, Chris; Norris, Patricia

    2015-01-01

    Workers are exposed to potential irritants and allergens with constant introduction of new industrial chemicals in the workplace. Characterize the final diagnoses, demographics, occupations, exposures, clinical presentations, patch test results, dermatologic histories, and risk factors of workers evaluated for suspected work-related allergic contact dermatitis (ACD). A retrospective chart review of 310 workers' compensation independent medical examinations evaluated for suspected work-related ACD was performed. Workers were seen in a community dermatology clinic in Portland, Oregon, from 2005 to 2014. Evaluation included history, physical examination, patch testing, and further diagnostic workup when indicated. Hand dermatitis was the most common presentation (n = 148, 47.7%). Prevalent occupations included health care workers (n = 51, 16.5%), custodial staff (n = 41, 13.2%), and machinists (n = 36, 11.6%). Allergic contact dermatitis (47.5%) was more common than irritant contact dermatitis (ICD) (38.9%) in those diagnosed as having occupational skin disease (n = 185). The highest-frequency work-related allergens were thiuram mix (21 of 88, 23.9%), carba mix (20 of 88, 22.7%), potassium dichromate (9 of 88, 10.2%), and epoxy resin (9 of 88, 10.2%). Allergic contact dermatitis and ICD are common occupational skin disorders. In this population of workers' compensation referrals, ACD was more common, with 73.3% of those cases work related, compared with 86.7% of ICD. Blue collar work and wet work were risk factors for the development of ACD and ICD.

  2. 20 Years of standard patch testing in an eczema population with focus on patients with multiple contact allergies

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Menné, Torkil; Johansen, Jeanne Duus

    2007-01-01

    Results of standard patch tests performed with the same methodology in one centre are rarely available over a large time span. This gives the unique opportunity to study not only prevalence but also persistency of contact allergy and characterize subpopulations. The objectives were to investigate...... sensitivity rates and persistencies of patch test results and characterize patients with multiple contact allergies. A 20-year retrospective database-based study of 14 998 patients patch tested with the European Standard Series was performed. 34.5% were sensitized, primarily women. Sensitivity to nickel......(Me)isothiazolinone, and primin and poor for paraben mix. 5.1% were multiple allergic, primarily women, and 90% got diagnosed by the first test. Frequency of multiple allergies increased with age. More multiple- than mono/double-allergic patients were tested multiple times. Persistency and sensitivity rates in a Danish eczema...

  3. Nickel allergy in patch-tested female hairdressers and assessment of nickel release from hairdressers' scissors and crochet hooks

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Milting, Kristina; Bregnhøj, Anne

    2009-01-01

    the proportion of hairdressers' scissors and crochet hooks that released an excessive amount of nickel and to determine the prevalence of nickel allergy among patch-tested female hairdressers. MATERIALS: Random hairdressers' stores in Copenhagen were visited. The dimethylglyoxime (DMG) test was used to assess...... excessive nickel release. The prevalence of nickel allergy among female hairdressers from the database at Gentofte Hospital was compared with the prevalence of nickel allergy among other consecutively patch-tested dermatitis patients. RESULTS: DMG testing showed that 1 (0.5%; 95% CI = 0 - 2.0) of 200 pairs...

  4. Common Allergens Identified Based on Patch Test Results in Patients with Suspected Contact Dermatitis of the Scalp.

    Science.gov (United States)

    Aleid, Nouf M; Fertig, Raymond; Maddy, Austin; Tosti, Antonella

    2017-03-01

    Contact dermatitis of the scalp is common and might be caused by many chemicals including metals, ingredients of shampoos and conditioners, dyes, or other hair treatments. Eliciting a careful history and patch tests are necessary to identify the responsible allergen and prevent relapses. To identify allergens that may cause contact dermatitis of the scalp by reviewing patch test results. We reviewed the records of 1,015 patients referred for patch testing at the Dermatology Department of the University of Miami. A total of 226 patients (205 females and 21 males) with suspected scalp contact dermatitis were identified, and the patch test results and clinical data for those patients were analyzed. Most patients were referred for patch testing from a specialized hair clinic at our institution. The most common allergens in our study population were nickel (23.8%), cobalt (21.0%), balsam of Peru (18.2%), fragrance mix (14.4%), carba mix (11.6%), and propylene glycol (PG) (8.8%). The majority of patients were females aged 40-59 years, and scalp itching or burning were reported as the most common symptom. Frequent sources of allergens for metals include hair clasps, pins, and brushes, while frequent sources of allergens for preservatives, fragrance mix, and balsam of Peru include shampoos, conditioners, and hair gels. Frequent sources of allergens for PG include topical medications.

  5. Common Allergens Identified Based on Patch Test Results in Patients with Suspected Contact Dermatitis of the Scalp

    Science.gov (United States)

    Aleid, Nouf M.; Fertig, Raymond; Maddy, Austin; Tosti, Antonella

    2017-01-01

    Background Contact dermatitis of the scalp is common and might be caused by many chemicals including metals, ingredients of shampoos and conditioners, dyes, or other hair treatments. Eliciting a careful history and patch tests are necessary to identify the responsible allergen and prevent relapses. Objectives To identify allergens that may cause contact dermatitis of the scalp by reviewing patch test results. Methods We reviewed the records of 1,015 patients referred for patch testing at the Dermatology Department of the University of Miami. A total of 226 patients (205 females and 21 males) with suspected scalp contact dermatitis were identified, and the patch test results and clinical data for those patients were analyzed. Most patients were referred for patch testing from a specialized hair clinic at our institution. Results The most common allergens in our study population were nickel (23.8%), cobalt (21.0%), balsam of Peru (18.2%), fragrance mix (14.4%), carba mix (11.6%), and propylene glycol (PG) (8.8%). The majority of patients were females aged 40–59 years, and scalp itching or burning were reported as the most common symptom. Conclusion Frequent sources of allergens for metals include hair clasps, pins, and brushes, while frequent sources of allergens for preservatives, fragrance mix, and balsam of Peru include shampoos, conditioners, and hair gels. Frequent sources of allergens for PG include topical medications. PMID:28611994

  6. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012.

    Science.gov (United States)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A; Silvestre, Juan F; Sánchez-Pérez, Javier; Weisshaar, Elke; Uter, Wolfgang

    2015-09-01

    Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. Data of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. The 'basic markers' were tested on 51 477 [fragrance mix II (FM II)] to 57 123 [Myroxylon pereirae, balsam of Peru] patients, and yielded positive reactions as follows: fragrance mix I 6.9%, Myroxylon pereirae 5.4%, FM II 3.8%, colophonium 2.6%, and hydroxyisohexyl 3-cyclohexene carboxaldehyde 1.7%, with some regional differences. Prevalences with TRUE Test(®) allergens were lower. Additional fragrances were tested on 3643 (trimethylbenzenepropanol) to 14 071 (oil of turpentine) patients, and yielded between 2.6% (Cananga odorata) and 0.7% (trimethylbenzenepropanol) positive reactions. Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. The human repeated insult patch test in the 21st century: a commentary.

    Science.gov (United States)

    Basketter, David A

    2009-01-01

    The human repeated insult patch test (HRIPT) is over half a century old, but is still used in several countries as a confirmatory test in the safety evaluation of skin sensitizers. This is despite the criticism it receives from an ethical perspective and regarding the scientific validity of such testing. In this commentary, the HRIPT is reviewed, with emphasis on ethical aspects and where the test can, and cannot, contribute in a scientifically meaningful manner to safety evaluation. It is concluded that where there is a specific rationale for testing, for example, to substantiate a no-effect level for a sensitizing chemical or to ensure that matrix effects are not making an unexpected contribution to sensitizing potency, then rigorous independent review may confirm that an HRIPT is ethical and scientifically justifiable. The possibility that sensitization may be induced in volunteers dictates that HRIPTs should be conducted rarely and in cases where the benefits overwhelmingly outweigh the risk. However, for the very large majority of HRIPTs conducted concerning the risk of skin sensitization, there is neither scientific justification nor any other merit.

  8. Identification and testing of early indicators for N leaching from urine patches.

    Science.gov (United States)

    Vogeler, Iris; Cichota, Rogerio; Snow, Val

    2013-11-30

    Nitrogen leaching from urine patches has been identified as a major source of nitrogen loss under intensive grazing dairy farming. Leaching is notoriously variable, influenced by management, soil type, year-to-year variation in climate and timing and rate of urine depositions. To identify early indicators for the risk of N leaching from urine patches for potential usage in a precision management system, we used the simulation model APSIM (Agricultural Production Systems SIMulator) to produce an extensive N leaching dataset for the Waikato region of New Zealand. In total, nearly forty thousand simulation runs with different combinations of soil type and urine deposition times, in 33 different years, were done. The risk forecasting indicators were chosen based on their practicality: being readily measured on farm (soil water content, temperature and pasture growth) or that could be centrally supplied to farms (such as actual and forecast weather data). The thresholds of the early indicators that are used to forecast a period for high risk of N leaching were determined via classification and regression tree analysis. The most informative factors were soil temperature, pasture dry matter production, and average soil water content in the top soil over the two weeks prior to the urine N application event. Rainfall and air temperature for the two weeks following urine deposition were also important to fine-tune the predictions. The identified early indicators were then tested for their potential to predict the risk of N leaching in two typical soils from the Waikato region in New Zealand. The accuracy of the predictions varied with the number of indicators, the soil type and the risk level, and the number of correct predictions ranged from about 45 to over 90%. Further expansion and fine-tuning of the indicators and the development of a practical N risk tool based on these indicators is needed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Hydroxyisohexyl 3-cyclohexene carboxaldehyde (lyral) in patch test preparations under varied storage conditions.

    Science.gov (United States)

    Hamann, Dathan; Hamann, Carsten R; Zimerson, Erik; Bruze, Magnus

    2013-01-01

    The common practice of preparing patch tests in advance has recently been called into question by researchers. It has been established that fragrance compounds are volatile and their testing efficacy may be affected by storage conditions and preparation. Allergens in fragrance mix I rapidly decrease in concentration after preapplication to test chambers. This study aimed to investigate the volatility of hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) in petrolatum when stored in test chambers and to explore the correlation between vapor pressure and allergen loss in petrolatum during preparation and storage. Standardized HICC in petrolatum was prepared and stored in IQ Chambers and Finn Chambers with covers at 5°C, 25°C, and 35°C, and concentration was analyzed at intervals for up to 9 days using gel permeation chromatography. Changes in HICC concentrations were not statistically significant at 8 hours at 5°C, 25°C, and 35°C. After 9 days, HICC concentrations were found to fall approximately 30% when stored at 35°C, 10% at 25°C, and less than 5% at 5°C. There was no significant difference between IQ and Finn chambers. Hydroxyisohexyl 3-cyclohexene carboxaldehyde concentrations are more stable in petrolatum than many other studied fragrance allergens, but HICC is still at risk for decreasing concentration when exposed to ambient air or heat for prolonged periods.

  10. Is the Atopy Patch Test Reliable in the Evaluation of Food Allergy-Related Atopic Dermatitis?

    Science.gov (United States)

    Mansouri, Mahboubeh; Rafiee, Elham; Darougar, Sepideh; Mesdaghi, Mehrnaz; Chavoshzadeh, Zahra

    2018-01-01

    Aeroallergens and food allergens are found to be relevant in atopic dermatitis. The atopy patch test (APT) can help to detect food allergies in children with atopic dermatitis. This study evaluates if the APT is a valuable tool in the diagnostic workup of children with food allergy-related atopic dermatitis. 42 children between 6 months and 12 years of age were selected at the Mofid Children Hospital. Atopic dermatitis was diagnosed, and the severity of the disease was determined. At the test visit, the patients underwent a skin prick test (SPT), APT, and serum IgE level measurement for cow's milk, egg yolk, egg white, wheat, and soy. We found a sensitivity of 91.7%, a specificity of 72.7%, a positive predictive value (PPV) of 88%, a negative predictive value (NPV) of 80%, and an accuracy of 85.7% for APT performed for cow's milk. APT performed for egg yolk had a sensitivity and a NPV of 100%, while the same parameters obtained with egg white were 84.2 and 75%, respectively. The sensitivity, specificity, and NPV of the APT for wheat were 100, 75, and 100%, respectively. The sensitivity, PPV, and NPV of the APT for soy were 87.5, 70, and 87.5%, respectively. Our data demonstrate that the APT is a reliable diagnostic tool to evaluate suspected food allergy-related skin symptoms in childhood and infancy. © 2018 S. Karger AG, Basel.

  11. Occupationally related contact dermatitis in North American food service workers referred for patch testing, 1994 to 2010.

    Science.gov (United States)

    Warshaw, Erin M; Kwon, Gina P; Mathias, C G Toby; Maibach, Howard I; Fowler, Joseph F; Belsito, Donald V; Sasseville, Denis; Zug, Kathryn A; Taylor, James S; Fransway, Anthony F; Deleo, Vincent A; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Zirwas, Matthew J; Dekoven, Joel G

    2013-01-01

    Contact dermatoses are common in food service workers (FSWs). This study aims to (1) determine the prevalence of occupationally related contact dermatitis among FSWs patch tested by the North American Contact Dermatitis Group (NACDG) and (2) characterize responsible allergens and irritants as well as sources. Cross-sectional analysis of patients patch tested by the NACDG, 1994 to 2010, was conducted. Of 35,872 patients patch tested, 1237 (3.4%) were FSWs. Occupationally related skin disease was significantly more common in FSWs when compared with employed non-FSWs. Food service workers were significantly more likely to have hand (P contact dermatitis in FSWs were 30.6% and 54.7%, respectively. Although the final diagnosis of irritant contact dermatitis was statistically higher in FSWs as compared with non-FSWs, allergic contact dermatitis was lower in FSWs as compared with non-FSWs. The most frequent currently relevant and occupationally related allergens were thiuram mix (32.5%) and carba mix (28.9%). Gloves were the most common source of responsible allergens. The NACDG standard tray missed at least 1 occupationally related allergen in 38 patients (4.3%). Among FSWs patch tested by the NACDG between 1994 and 2010, the most common allergens were thiuram mix and carba mix. Gloves were the most common source of responsible allergens.

  12. Survey of Occupational Allergic Contact Dermatitis and Patch Test among Clothing Employees in Beijing.

    Science.gov (United States)

    Chen, Yu-Xin; Gao, Bing-Ai; Cheng, Hai-Yan; Li, Lin-Feng

    2017-01-01

    Occupational population-based epidemiological data relating to occupational contact allergies in the Chinese clothing industry are limited. To investigate the prevalence of occupational allergic contact dermatitis (OACD) and to identify the causative allergens among clothing employees in China, a cross-sectional study was conducted in 529 clothing employees at 12 clothing factories in Beijing. All employees were subjected to an interview using self-administered questionnaire and skin examination, and those who were diagnosed with occupational contact dermatitis (OCD) were patch tested. In the present survey, we found that the overall 1-year prevalence of OACD among the clothing employees was 8.5%. The 1-year prevalence of OACD among workers (10.8%) was significantly higher than that among managers (3.2%). The lesions were primarily on the hands and wrists in workers, but the face and neck in managers. The major allergens were nickel sulfate and cobalt dichloride in workers and colophony and p -tert-butylphenol formaldehyde resin in managers. In conclusion, workers are at a higher risk of OACD compared with managers in the Chinese clothing industry. In addition to hand dermatitis in workers, airborne contact dermatitis on the face and neck should be also addressed in managers.

  13. Role of atopy patch test for diagnosis of food allergy-related gastrointestinal symptoms in children.

    Science.gov (United States)

    Boonyaviwat, Onsuree; Pacharn, Punchama; Jirapongsananuruk, Orathai; Vichyanond, Pakit; Visitsunthorn, Nualanong

    2015-12-01

    Double-blind, placebo-controlled food challenge is the gold standard for diagnosing food allergy. However, it is a time-consuming procedure and requires onsite medical supervision and resuscitating medicines and devices on hand. The objective of this study was to compare the atopy patch test (APT) with the oral food challenge test (OFC) in children with suspected food allergy-related gastrointestinal (GI) symptoms. A prospective self-controlled study enrolled children with a history of suspected food allergy-related GI symptoms. Skin prick test (SPT) and APT using lyophilized and commercial allergen extracts for cow's milk, egg, wheat, soy, and shrimp were evaluated, and OFC was performed. Thirty-nine patients (25 boys, median age 2.4 yrs) with 76 events of suspected food allergy-related GI symptoms were enrolled. SPT was positive in 11/76 events (14.5%). Sensitivity, specificity, predictive values, and likelihood ratio were calculated related to the food challenge outcome. Of 41 OFC, 30 (73.2%) were positive. APT using lyophilized allergen extracts yielded high sensitivity (80%) and high positive predictive value (85.7%). APT using commercial allergen extracts yielded low sensitivity (30%) but high specificity (90%). The negative predictive value of APT using lyophilized and commercial allergen extracts was 53.8% and 32.2%, respectively. All cases with positive APT using lyophilized allergen extracts together with positive SPT also had positive OFC. In contrast to commercial extracts, APT with lyophilized allergen extracts is reliable, safe, and maybe useful for the diagnosis of suspected food allergy-related GI symptoms in children. OFC is still needed in most of the cases. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Association between positive patch tests to epoxy resin and fragrance mix I ingredients

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Christensen, Lars Porskjaer; Vølund, Aage

    2009-01-01

    and possibly reproduce this association with the use of TRUE((R)) test data and supplementary tests with fragrance mix ingredients from the Department of Dermatology, Odense University Hospital. MATERIALS AND METHODS: Six thousand one hundred and fifteen consecutive eczema patients tested from 1995 to 2007......BACKGROUND: Both epoxy resin (diglycidyl ether of bisphenol A) and fragrance mix I are included in the European baseline series of contact allergens. A significant association between positive reactions to epoxy resin and fragrance mix has been reported by others. OBJECTIVE: To investigate...... were included, and test results from all patients tested with fragrance mix ingredients were analysed. RESULTS: One hundred and forty-five (2.4%) were positive to epoxy resin and 282 (4.6%) were positive to fragrance mix I. Nineteen were positive to both giving an odds ratio of 3.3, which...

  15. Tuberculin skin testing: Spectrum of adverse reactions.

    Science.gov (United States)

    Praveen, Ramar; Bahuguna, Amit; Dhadwal, Bhumesh Singh

    2015-01-01

    Tuberculin skin testing (TST) is one of the primary diagnostic modalities recommended by the World Health Organization (WHO) and the National Institute for Health and Care Excellence (NICE) study conducted in the United Kingdom (UK) for diagnosing tuberculosis (TB). Even after acceptance as a diagnostic modality and stern standardization, TST has its own flaws that include a spectrum of adverse reactions. We report a series of cases with a spectrum of adverse reactions occurring with a higher frequency than present in the available evidence. The study has some demerits such as being a retrospective one with interobserver variation and lack of histopathological confirmation. The observation is presented to accentuate the fact that adverse reactions are not a rarity and that further studies are required to establish the cause and exact incidence of the same.

  16. Occupational contact dermatitis in painters - an analysis of patch test data from the Danish Contact Dermatitis Group

    DEFF Research Database (Denmark)

    Mose, Anja P; Lundov, Michael Dyrgaard; Zachariae, Claus

    2012-01-01

    Background. Painters are among the occupational groups that most commonly experience occupational contact dermatitis, but few investigations exist concerning this occupation. Objectives. To characterize painters with contact dermatitis and identify the most common allergens associated...... with the occupation. Materials and methods. All patch test results of 219 painters and 1095 matched controls registered by the Danish Contact Dermatitis Group between 2001 and 2010 were analysed. Results. Hand eczema (p contact dermatitis (p

  17. Shoe contact dermatitis from dimethyl fumarate: clinical manifestations, patch test results, chemical analysis, and source of exposure.

    Science.gov (United States)

    Giménez-Arnau, Ana; Silvestre, Juan Francisco; Mercader, Pedro; De la Cuadra, Jesus; Ballester, Isabel; Gallardo, Fernando; Pujol, Ramón M; Zimerson, Erik; Bruze, Magnus

    2009-11-01

    The methyl ester form of fumaric acid named dimethyl fumarate (DMF) is an effective mould-growth inhibitor. Its irritating and sensitizing properties were demonstrated in animal models. Recently, DMF has been identified as responsible for furniture contact dermatitis in Europe. To describe the clinical manifestations, patch test results, shoe chemical analysis, and source of exposure to DMF-induced shoe contact dermatitis. Patients with suspected shoe contact dermatitis were studied in compliance with the Declaration of Helsinki. Patch test results obtained with their own shoe and the European baseline series, acrylates and fumaric acid esters (FAE), were recorded according to international guidelines. The content of DMF in shoes was analysed with gas chromatography and mass spectrometry. Acute, immediate irritant contact dermatitis and non-immunological contact urticaria were observed in eight adults and two children, respectively. All the adult patients studied developed a delayed sensitization demonstrated by a positive patch testing to DMF Global preventive measures for avoiding contact with DMF are necessary.

  18. EX1301: Ship Shakedown and Patch Test Exploration, NE Canyons and Seamounts on NOAA Ship Okeanos Explorer between 20130318 and 20130405

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Following annual ship shakedown and patch tests, EX1301 will complete the comprehensive mapping of the Northeast canyons and the adjacent continental shelf carried...

  19. Sesquiterpene lactone mix patch testing supplemented with dandelion extract in patients with allergic contact dermatitis, atopic dermatitis and non-allergic chronic inflammatory skin diseases.

    Science.gov (United States)

    Jovanović, M; Poljacki, M; Mimica-Dukić, N; Boza, P; Vujanović, Lj; Duran, V; Stojanović, S

    2004-09-01

    We investigated the value of patch testing with dandelion (Compositae) extract in addition to sesquiterpene lactone (SL) mix in selected patients. After we detected a case of contact erythema multiforme after patch testing with dandelion and common chickweed (Caryophyllaceae), additional testing with common chickweed extract was performed. A total of 235 adults with a mean age of 52.3 years were tested. There were 66 men and 169 women: 53 consecutive patients with allergic contact dermatitis (ACD); 43 with atopic dermatitis (AD); 90 non-atopics suffering from non-allergic chronic inflammatory skin diseases; 49 healthy volunteers. All were tested with SL mix 0.1% petrolatum (pet.) and diethyl ether extracts from Taraxacum officinale (dandelion) 0.1 and 3.0% pet. and from Stellaria media (common chickweed) 0.1 and 3% pet. A total of 14 individuals (5.9%) showed allergic reaction (AR) to at least 1 of the plant allergens, 4 (28.6%) to common chickweed extract, and 11 (78.6%) to Compositae allergens. These 11 persons made the overall prevalence of 4.7%: 8 (3.4%) were SL-positive and 3 (1.3%) reacted to dandelion extract. 5 persons (45.5%) had AD, 2 had ACD, 2 had psoriasis and 2 were healthy controls. The Compositae allergy was relevant in 8 cases (72.7%). The highest frequency of SL mix sensitivity (9.3%) was among those with AD. Half the SL mix-sensitive individuals had AD. ARs to dandelion extract were obtained only among patients with eczema. A total of 9 irritant reactions (IRs) in 9 individuals (3.8%) were recorded, 8 to SL mix and 1 to common chickweed extract 3.0% pet. No IR was recorded to dandelion extract (P = 0.007). Among those with relevant Compositae allergy, 50.0% had AR to fragrance mix and balsam of Peru (Myroxylon pereirae resin) and colophonium. SLs were detected in dandelion but not in common chickweed. Our study confirmed the importance of 1 positive reaction for emerging, not fully established, Compositae allergy. In conclusion, the overall

  20. Cyclical and patch-like GDNF distribution along the basal surface of Sertoli cells in mouse and hamster testes.

    Directory of Open Access Journals (Sweden)

    Takeshi Sato

    Full Text Available BACKGROUND AND AIMS: In mammalian spermatogenesis, glial cell line-derived neurotrophic factor (GDNF is one of the major Sertoli cell-derived factors which regulates the maintenance of undifferentiated spermatogonia including spermatogonial stem cells (SSCs through GDNF family receptor α1 (GFRα1. It remains unclear as to when, where and how GDNF molecules are produced and exposed to the GFRα1-positive spermatogonia in vivo. METHODOLOGY AND PRINCIPAL FINDINGS: Here we show the cyclical and patch-like distribution of immunoreactive GDNF-positive signals and their close co-localization with a subpopulation of GFRα1-positive spermatogonia along the basal surface of Sertoli cells in mice and hamsters. Anti-GDNF section immunostaining revealed that GDNF-positive signals are mainly cytoplasmic and observed specifically in the Sertoli cells in a species-specific as well as a seminiferous cycle- and spermatogenic activity-dependent manner. In contrast to the ubiquitous GDNF signals in mouse testes, high levels of its signals were cyclically observed in hamster testes prior to spermiation. Whole-mount anti-GDNF staining of the seminiferous tubules successfully visualized the cyclical and patch-like extracellular distribution of GDNF-positive granular deposits along the basal surface of Sertoli cells in both species. Double-staining of GDNF and GFRα1 demonstrated the close co-localization of GDNF deposits and a subpopulation of GFRα1-positive spermatogonia. In both species, GFRα1-positive cells showed a slender bipolar shape as well as a tendency for increased cell numbers in the GDNF-enriched area, as compared with those in the GDNF-low/negative area of the seminiferous tubules. CONCLUSION/SIGNIFICANCE: Our data provide direct evidence of regionally defined patch-like GDNF-positive signal site in which GFRα1-positive spermatogonia possibly interact with GDNF in the basal compartment of the seminiferous tubules.

  1. The sensitization potential of sunscreen after ablative fractional skin resurfacing using modified human repeated insult patch test.

    Science.gov (United States)

    Boonchai, Waranya; Sathaworawong, Angkana; Wongpraparut, Chanisada; Wanitphakdeedecha, Rungsima

    2015-10-01

    Ablative fractional skin resurfacing has become popular and proven to be useful in treating scars, photoaging and wrinkles. Although post-inflammatory hyperpigmentation (PIH) is the most common complication especially in dark-skinned patients like Asian. Several modalities have been used to overcome the PIH. To determine the sensitization potential of sunscreen applied immediately after ablative fractional skin resurfacing. Sixty volunteers were recruited. Of these 30 subjects were from previous ablative fractional skin resurfacing study who applied broad-spectrum sunscreen containing anti-inflammatory agent starting on the first day after resurfacing and another 30 non-resurfacing subjects had applied the same sunscreen on the intact skin. All subjects were patch/photopatch tested for sensitization study by using modified human repeated insult patch test (HRIPT). There were significantly higher sensitization rate of UV-filter, octocrylene and the sunscreen in resurfacing group than in non-resurfacing group. Early application of sunscreen after ablative fractional skin resurfacing has increased the incidence of sensitization potential of sunscreen. The sunscreen is recommended to start using from D3 after fractional ablative skin resurfacing to ensure the complete recovery of skin barrier and minimize the risk of sensitization.

  2. Changes in the Patch Test Population Over a Ten-Year Period at the Contact Dermatitis Clinic, Siriraj Hospital: A University-Based Tertiary Care Hospital in Thailand

    Directory of Open Access Journals (Sweden)

    Sutasinee Phaitoonwattanakij

    2017-01-01

    Full Text Available Background: There are several factors which have an impact on patch test results. In the past, comparing the populations between different institutes, without appropriate indicators was difficult. Thus, the MOAHLFA index (Male, Occupational, Atopic dermatitis, Hand dermatitis, Leg dermatitis, Face dermatitis and Age above 40 years was developed. However, the study of this index in Thailand is limited. Objective: To investigate the MOAHLFA index in patch testing population in the Contact Dermatitis Clinic at Siriraj Hospital. Methods: The clinical parameters of patients who underwent patch testing at Contact Dermatitis Clinic, Siriraj Hospital during 10 years were studied. Results: Our patch test population showed a statistically significant increase in the proportion of male and patients aged above 40 years while a statistical decrease was found in those with occupational skin diseases with a history of atopic dermatitis, and lesions on the hands during a decade. Conclusion: This study revealed patch-test population attending Siriraj contact dermatitis clinic changed in 10-years period. According to MOAHLFA index, the changes were increasing of male, aged >40 years but decreasing of atopic, occupational-related contact allergy patients.

  3. Ethosome formulation of contact allergens may enhance patch test reactions in patients

    DEFF Research Database (Denmark)

    Madsen, Jakob Torp; Vogel, Stefan; Karlberg, Ann-Therese

    2010-01-01

    Background: Ethosomes and liposomes are ultra-small vesicles capable of encapsulating drugs and cosmetic ingredients for topical use, thereby potentially increasing bioavailability and clinical efficacy. So far, few reports have suggested that formulation of cosmetic ingredients in vesicular...

  4. Quantitative aspects of isoeugenol contact allergy assessed by use and patch tests

    DEFF Research Database (Denmark)

    Johansen, J D; Andersen, Klaus Ejner; Menné, T

    1996-01-01

    in 4/19 (20%) of the test subjects. The ROAT was performed with a test solution of 0.2% isoeugenol in ethanol, which is the recommended maximum concentration used in perfumes, ethanol being applied as vehicle control. 4 weeks was the maximum exposure period. The upper arm was used as test site the 1st...

  5. Viability of meta-populations of wetland birds in a fragmented landscape: Testing the key-patch approach

    NARCIS (Netherlands)

    Vermaat, J.E.; Vigneau, N.; Omtzigt, N.

    2008-01-01

    The key patch approach assumes that metapopulations in fragmented landscapes are likely to be viable with at least one "key" sub-population that is sufficiently large to ensure re-colonization of surrounding minor habitat patches. It is based on a minimum viable number of breeding pairs and

  6. Comparison of simultaneous patch testing with parthenolide and sesquiterpene lactone mix

    DEFF Research Database (Denmark)

    Orion, E; Paulsen, Evy; Andersen, Klaus Ejner

    1998-01-01

    Several studies have pointed out that the sesquiterpene lactone (SL) mix is a safe, though inadequate, screen for Compositae allergy. To test the usefulness of the sesquiterpene lactone parthenolide as a supplementary Compositae screening test to the mix, both were included in the standard series...

  7. Growing pains : how drug testing keeps workers and assets safe in a booming oil patch

    Energy Technology Data Exchange (ETDEWEB)

    Paulgaard, T S

    2006-06-15

    Drug abuse has become a subject of concern to the oil and gas industry, where mistakes in the operation of large machines can result in injury, death and the loss of millions of dollars. Pre-employment urine tests are becoming standard procedure in the oil field. Many supervisors refuse to let employees start work without a clear test. Urine samples are tested for the presence of cannabis, cocaine, opiates, amphetamines and phencyclidine. When a worker is injured or killed on the job, or after an uncommon error that causes significant damage, all parties involved are tested as soon as possible and a receipt of the results are expedited. The Alberta Human Rights and Citizenship Commission is now addressing the issue of drug testing, and has ascertained that drug and alcohol testing are only allowable in certain circumstances, and that it is discriminatory to test potential or existing employees for drug and alcohol use if the testing is not reasonable or justifiable. They have also suggested that there is a duty to accommodate persons with disabilities in the workplace. Drug and alcohol dependency fall within the meaning of disabled. Under the Construction Owner's Association of Alberta's Canadian Model for a Safe Workplace, testing must work in concert with treatment. Current employees are directed to seek help via an employee assistant plan. Workers and supervisors report that drug use is rampant in work camps. Industry-wide, fail rates for those who take part in drug testing are quoted by experts as ranging from between 2 to 14 per cent. 2 figs.

  8. Growing pains : how drug testing keeps workers and assets safe in a booming oil patch

    Energy Technology Data Exchange (ETDEWEB)

    Paulgaard, T.S.

    2006-06-15

    Drug abuse has become a subject of concern to the oil and gas industry, where mistakes in the operation of large machines can result in injury, death and the loss of millions of dollars. Pre-employment urine tests are becoming standard procedure in the oil field. Many supervisors refuse to let employees start work without a clear test. Urine samples are tested for the presence of cannabis, cocaine, opiates, amphetamines and phencyclidine. When a worker is injured or killed on the job, or after an uncommon error that causes significant damage, all parties involved are tested as soon as possible and a receipt of the results are expedited. The Alberta Human Rights and Citizenship Commission is now addressing the issue of drug testing, and has ascertained that drug and alcohol testing are only allowable in certain circumstances, and that it is discriminatory to test potential or existing employees for drug and alcohol use if the testing is not reasonable or justifiable. They have also suggested that there is a duty to accommodate persons with disabilities in the workplace. Drug and alcohol dependency fall within the meaning of disabled. Under the Construction Owner's Association of Alberta's Canadian Model for a Safe Workplace, testing must work in concert with treatment. Current employees are directed to seek help via an employee assistant plan. Workers and supervisors report that drug use is rampant in work camps. Industry-wide, fail rates for those who take part in drug testing are quoted by experts as ranging from between 2 to 14 per cent. 2 figs.

  9. Effects of different base agents on prediction of skin irritation by sodium lauryl sulfate using patch testing and repeated application test.

    Science.gov (United States)

    Horita, Kotomi; Horita, Daisuke; Tomita, Hiroyuki; Yasoshima, Mitsue; Yagami, Akiko; Matsunaga, Kayoko

    2017-05-01

    Animal testing for cosmetics was banned in the European Union (EU) in 2013; therefore, human tests to predict and ensure skin safety such as the patch test or usage test are now in demand in Japan as well as in the EU. In order to investigate the effects of different bases on the findings of tests to predict skin irritation, we performed patch testing (PT) and the repeated application test (RAT) using sodium lauryl sulfate (SLS), a well-known irritant, dissolved in 6 different base agents to examine the effects of these bases on skin irritation by SLS. The bases for PT were distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream. The concentrations of SLS were 0.2% and 0.5%. Twelve different base combinations were applied to the normal back skin of 19 individuals for 24h. RAT was performed with distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream containing SLS at concentrations of 0.2%, 2%, and 5%, being applied to the arms of the same PT subjects. The test preparation of each base was applied at the same site, with 0.2% SLS being used in the first week, 2% SLS in the following week, and 5% SLS in the final week. The results of PT revealed that skin irritation scores varied when SLS at the same concentration was dissolved in a different base. The results of RAT showed that although skin irritation appeared with every base at a concentration of 5%, the positive rate was approximately the same. In conclusion, our results suggest that skin irritation elicited in PT depends on the base, while in RAT, it does not depend on the type of base employed. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Testing string dynamics in lepton nucleus reactions

    International Nuclear Information System (INIS)

    Gyulassy, M.; Pluemer, M.

    1989-10-01

    The sensitivity of nuclear attenuation of 10-100 GeV lepton nucleus (ell A) reactions to space-time aspects of hadronization is investigated within the context of the Lund string model. We consider two mechanisms for attenuation in a nucleus: final state cascading and string flip excitations. Implications for the evolution of the energy density in nuclear collisions are discussed. 16 refs., 10 figs

  11. Methods for transfer a saliva based alcohol content test to a dermal patch

    Energy Technology Data Exchange (ETDEWEB)

    Silks, III, Louis A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-03

    Detection and quantitation of ethanol which is highly sensitive, specific, and efficient has been a commercial target for sometime. Clearly analytical methods are useful such as gas and liquid chromatography, mass spectrometry, and NMR spectroscopy. However, those methods are best used in the laboratory and a less useful for detection and quantitation of ethanol in the field. Enzymes have been employed for the detection and quantitation of EtOH. Enzymes are proteins that perform a particular task in a bio-catalytic way. Most of the chemistry that these enzymes do are frequently exquisitely specific in that only one alcohol reacts and only one product is produced. One enzyme molecule can catalyze the reaction of numerous substrate molecules which in itself is an amplification of the recognition signal. Alcohol dehydrogenase (ADH) and alcohol oxidase (AO) are two possible enzymatic targets for EtOH sensor development.1 The ADH oxidizes the alcohol using a co-factor nicotinamide adenine dinucleotide. This co-factor needs to be within close proximity of the ADH. AO also oxidizes the ethanol using molecular oxygen giving rise to the production of the aldehyde and hydrogen peroxide.

  12. Patch test results of hand eczema patients : relation to clinical types

    NARCIS (Netherlands)

    Boonstra, M B; Christoffers, W A; Coenraads, P J; Schuttelaar, M L A

    BACKGROUND: Allergic contact dermatitis is a well-known cause of hand eczema, although the influence of contact allergens on different clinical types of hand eczema remains still unclear. OBJECTIVE: To identify most common positive tested allergens among hand eczema patients and to define the

  13. Patch Testing To a Textile Dye Mix by the International Contact Dermatitis Research Group

    DEFF Research Database (Denmark)

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus E

    2015-01-01

    .2%. The most frequent dye allergen in the TDM-positive patients was D Orange 3. CONCLUSIONS: Over 30% of the TDM allergic patients had been missed if only the international baseline series was tested. Contact allergy to TDM could explain or contribute to dermatitis in over 20% of the patients. Textile dye mix...... should be considered for inclusion into the international baseline series....

  14. Accelerated stability testing of a transdermal patch composed of eserine and pralidoxime chloride for prophylaxis against (±-anatoxin A poisoning

    Directory of Open Access Journals (Sweden)

    Subham Banerjee

    2014-06-01

    Full Text Available The current study evaluated the stability potential of a transdermal patch composed of eserine and pralidoxime chloride for prophylaxis against (±-anatoxin A poisoning. The drug combinations were fabricated in an adhesive matrix system supported by a backing membrane and attached to a temporary release liner. Stability testing of the optimized formulation was established for 6 months under accelerated study conditions as per International Conference on Harmonisation guidelines. Results obtained after 6 months showed that the optimized patch formulation was stable with respect to drugs content, pH, diffusion, visual inspection, and other analytical parameters.

  15. Evaluation of the medical devices benchmark materials in the controlled human patch testing and in the RhE in vitro skin irritation protocol.

    NARCIS (Netherlands)

    Kandárová, Helena; Bendova, Hana; Letasiova, Silvia; Coleman, Kelly P; De Jong, Wim H; Jírova, Dagmar

    2018-01-01

    Several irritants were used in the in vitro irritation medical device round robin. The objective of this study was to verify their irritation potential using the human patch test (HPT), an in vitro assay, and in vivo data. The irritants were lactic acid (LA), heptanoic acid (HA), sodium dodecyl

  16. Critically appraised topic on adverse food reactions of companion animals (4): can we diagnose adverse food reactions in dogs and cats with in vivo or in vitro tests?

    Science.gov (United States)

    Mueller, Ralf S; Olivry, Thierry

    2017-08-30

    The gold standard to diagnose adverse food reactions (AFRs) in the dog and cat is currently an elimination diet with subsequent provocation trials. However, those trials are inconvenient and client compliance can be low. Our objective was to systematically review the literature to evaluate in vivo and in vitro tests used to diagnose AFR in small animals. We searched three databases (CAB Abstracts, MEDLINE and Web of Science) for pertinent references on September 16, 2016. Among 71, 544 and 41 articles found in the CAB Abstract, MEDLINE and Web of Science databases, respectively, we selected 22 articles and abstracts from conference proceedings that reported data usable for evaluation of tests for AFR. Serum tests for food-specific IgE and IgG, intradermal testing with food antigens, lymphocyte proliferation tests, fecal food-specific IgE, patch, gastroscopic, and colonoscopic testing were evaluated. Testing for serum food-specific IgE and IgG showed low repeatability and, in dogs, a highly variable accuracy. In cats, the accuracy of testing for food-specific IgE was low. Lymphocyte proliferation tests were more frequently positive and more accurate in animals with AFR, but, as they are more difficult to perform, they remain currently a research tool. All other reported tests were only evaluated by individual studies with small numbers of animals. Negative patch test reactions have a very high negative predictability in dogs and could enable a choice of ingredients for the elimination diet in selected patients. Gastroscopic and colonoscopic testing as well as food-specific fecal IgE or food-specific serum IgG measurements appear less useful. Currently, the best diagnostic procedure to identify AFRs in small animals remains an elimination diet with subsequent provocation trials.

  17. Allergic contact dermatitis pattern in Kuwait: nickel leads the pack. In-depth analysis of nickel allergy based on the results from a large prospective patch test series report

    Science.gov (United States)

    Almutawa, Fahad

    2017-01-01

    Introduction Contact dermatitis is a relatively common dermatosis reported among several population groups from all around the globe. However, the data from Kuwait is unavailable. Patch tests are essential for the diagnosis of contact sensitization. Aim To determine a relative frequency and pattern of sensitizers to different allergens in patients of suspected contact dermatitis in Kuwait and, also to study the role of the commonest sensitizer in detail. Material and methods Patch tests were performed in 2461 consecutive patients with a clinical diagnosis of contact dermatitis seen at our hospital between September 1, 2014 and August 31, 2015. Out of the total of 1381 (56.1%) patients with positive patch test results to at least one allergen, 546 (22.2%) patients with a single positive reaction to nickel only (single largest sensitizer) were selected as the study population for further detailed analysis. Results At least one positive patch test reaction was found in 1381 (56.12%) patients. Nickel was found to be the most common sensitizer seen in 546 (40%) patients. The mean age was 37.3 ±13.8 years and the mean duration of disease was 27.3 ±13.8 months. Most (387/546) patients sensitized were females. The forearms/hands and wrists were the most prevalent sites (52.56% of the participants). In 58.91% of women, dermatitis was more often confined to other sites, mostly ears and the neck due to earrings and necklaces. Just more than half of the number (51.09%) of nickel allergic patients were found in the age group of 15–25 years. Hairdressers/beauticians were the most affected group followed by house workers (housewives, cleaners, housekeepers). Conclusions Nickel is the single most common sensitizer found in our patients, and female sex, young age, occupation with long hours of contact to nickel are high risk factors. We recommend that a directive, which limits the release of nickel from products with extended skin contact, be approved in Kuwait. PMID:28670248

  18. Time reversal tests in polarized neutron reactions

    International Nuclear Information System (INIS)

    Asahi, Koichiro; Bowman, J.D.; Crawford, B.

    1998-01-01

    This is the final report of a three-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). In recent years the nuclear weak interaction has been studied in the compound nucleus via parity violation. The observed parity-violating effects are strongly enhanced by nuclear structure. The predictions are that the interaction of polarized neutrons with polarized nuclear targets could be also used to perform sensitive tests of time-reversal-violation because of the nuclear enhancements. The author has designed experiments to search for time-reversal violation in neutron-nucleus interactions. He has also developed techniques to polarize neutrons with laser-polarized 3 He gas targets. Using the polarized 3 He neutron spin filter, he has performed two experiments at LANSCE: an absolute neutron beam polarization measurement with an accuracy of 0.2--0.3% and a neutron spin-rotation measurement on a 139 La sample

  19. Occupational Contact Dermatitis in Mechanics and Repairers Referred for Patch Testing: Retrospective Analysis From the North American Contact Dermatitis Group 1998-2014.

    Science.gov (United States)

    Warshaw, Erin M; Hagen, Solveig L; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel G; Belsito, Donald V; Fowler, Joseph F; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Zirwas, Matthew J; Storrs, Frances J

    Contact dermatoses are common in mechanic and repair occupations. This study aimed to (1) estimate the prevalence of occupationally related contact dermatitis among mechanics/repairers patch tested from 1998 to 2014 by the North American Contact Dermatitis Group, (2) characterize responsible allergens and irritants, and their sources, and (3) compare results among 3 occupational subgroups (mechanics, electrical/electronic, and other). A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 1998 and 2014. Of 38,784 patients patch tested, 691 (1.8%) were mechanics/repairers. Male sex (93.5%) and hand involvement (59.5%) were common overall. Occupationally related skin disease was more prevalent among vehicle and mobile equipment mechanics/repairers (52.7%) and other mechanics/repairers (41.4%) than electrical/electronic equipment mechanics/repairers (21.3%). Overall, carba mix, thiuram mix, and methylchloroisothiazolone/methylisothiazolone were the most common occupation-related clinically relevant allergens. Gloves, automotive vehicles, solvents, oils, lubricants, and fuels were the most common sources of responsible allergens. Common occupationally related allergens included rubber accelerators and the preservative methylchloroisothiazolone/methylisothiazolone.

  20. Pharmacogenetics and Predictive Testing of Drug Hypersensitivity Reactions.

    Science.gov (United States)

    Böhm, Ruwen; Cascorbi, Ingolf

    2016-01-01

    Adverse drug reactions adverse drug reaction (ADR) occur in approximately 17% of patients. Avoiding ADR is thus mandatory from both an ethical and an economic point of view. Whereas, pharmacogenetics changes of the pharmacokinetics may contribute to the explanation of some type A reactions, strong relationships of genetic markers has also been shown for drug hypersensitivity belonging to type B reactions. We present the classifications of ADR, discuss genetic influences and focus on delayed-onset hypersensitivity reactions, i.e., drug-induced liver injury, drug-induced agranulocytosis, and severe cutaneous ADR. A guidance how to read and interpret the contingency table is provided as well as an algorithm whether and how a test for a pharmacogenetic biomarker should be conducted.

  1. A clinical study of transdermal contraceptive patch in Thai adolescence women.

    Science.gov (United States)

    Piyasirisilp, Rachatapon; Taneepanichskul, Surasak

    2008-02-01

    To study cycle control, compliance and safety of a transdermal contraceptive patch in adolescent Thai women. Fifty-eight healthy women were assigned to receive 3 cycles of contraceptive patch (ethinyl estradiol 20 microg and norelgestromin 150 microg/day). All participants aged 16-20 years were invited to participate from the family planning clinic at King Chulalongkorn Memorial Hospital. Data were collected on adverse effects, perceived advantages and disadvantages, body weight, blood pressure, patch detachments and compliance. Data were analyzed using mean, percentage and student's t-test. The participants' average age was 19.4 years, height 158.8 cm, weight 51.8 kg, BMI 20.8 Kg/m2. The most location of patch application was the abdomen and the most adverse event was breast tenderness (31.0%) followed by application site reaction, nausea vomiting and headache respectively. The breast symptom was mild in severity. The participants reported decrease in dysmenorrhea and shorter duration of bleeding. There were no significant changes in body weight and blood pressure. The improvement of their facial acne was reported. There were no pregnancies during use and the adhesion of the contraceptive patch is excellent. Partial patch detachment was reported in only 6.9%. No completed patch detachment was found. The present study found an overall positive impression of a new transdermal contraceptive patch. The good compliance and few side effects were demonstrated. The adhesive patch contraceptive was excellent.

  2. Oceanographic data collected during the EX1601 Transit and Mission Patch Test on NOAA Ship OKEANOS EXPLORER in the North Pacific Ocean from 2016-01-20 to 2016-02-07 (NCEI Accession 0145341)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Normal underway operations and mapping patch testing. Bathymetric mapping of either the Murray or Molokai Fracture Zones during the transit to Hawaii was planned, as...

  3. Oceanographic data collected during the EX1401 (Ship Shakedown and Patch Test Exploration) expedition on NOAA Ship OKEANOS EXPLORER in the North Atlantic Ocean from 2014-02-06 to 2014-02-09 (NODC Accession 0116846)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — To begin the 2014 NOAA Ship Okeanos Explorer field season, a ship shakedown and multibeam patch test was performed off the coast of Rhode Island over Veatch Canyon....

  4. Construct validity and reliability of automated body reaction test ...

    African Journals Online (AJOL)

    Automated Body Reaction Test (ABRT) is a new device for skills and physical assessment instrument to measure ability on react, move quickly and accurately in accordance with stimulus. A total of 474 subjects aged 7-17 years old were randomly selected for the construct validity (n=330) and reliability (n=144). The ABRT ...

  5. Sodium-water reaction test facility (SWAT-3)

    International Nuclear Information System (INIS)

    Shimazu, Hisashi; Ukechi, Kazutoshi; Sasakura, Kazutake; Kusunoki, Junichi

    1976-01-01

    In the development of the liquid metal cooled fast breeder reactor (LMFBR), the steam generator (SG) is considered one of the most important components. The Power Reactor and Nuclear Fuel Development Corporation (PNC) is now promoting the research and development of the SG system used with the prototype fast breeder reactor ''Monju''. In this research, the phenomena of the sodium-water reaction in the SG are the key which must be investigated for the solution of problems. The test facility (SWAT-3) simulating Monju's SG on the scale of 1/2.5 was designed, fabricated and installed by IHI at Oarai Engineering Center of PNC, its pre-operation being accomplished in February 1975. The purpose of SWAT-3 is summarized as follows: (1) To perform an overall test on the safety of Monju's SG and intermediate heat transport system under the design condition against sodium-water reaction accidents. (2) To investigate the damage of the SG structure caused by the sodium-water reaction, and the possibility of repair and recovery operations. The first test was accomplished successfully on June 9, 1975. As a result of the test, the fundamental function of this test facility was proven to be satisfactory as expected. (auth.)

  6. Experimental test of exchange degeneracy in hypercharge exchange reactions

    International Nuclear Information System (INIS)

    Moffeit, K.C.

    1978-10-01

    Two pairs of line-reversed reactions π + P → K + Σ + , K - p → π - Σ + and π + p → K + Y* + (1385), K - p → π - Y* + (1385) provide an experimental test of exchange degeneracy in hypercharge exchange reactions. From their study it is concluded that in contrast to the lower energy data, the 11.5 results for the two pairs of reactions are consistent with exchange degeneracy predictions for both helicity-flip and nonflip amplitudes. The Y(1385) decay angular distributions indicate that the quark model and Stodolsky--Sakurai predictions are in agreement with the main features of the data. However, small violations are observed at small momentum transfer. While the Y(1385) vertex is helicity-flip dominated, the nonvanishing of T/sub 3/2 - 1/2/ and T/sub -3/2 1/2/ suggests some finite helicity nonflip contribution in the forward direction. 23 references

  7. Patching. Restitching business portfolios in dynamic markets.

    Science.gov (United States)

    Eisenhardt, K M; Brown, S L

    1999-01-01

    In turbulent markets, businesses and opportunities are constantly falling out of alignment. New technologies and emerging markets create fresh opportunities. Converging markets produce more. And of course, some markets fade. In this landscape of continuous flux, it's more important to build corporate-level strategic processes that enable dynamic repositioning than it is to build any particular defensible position. That's why smart corporate strategists use patching, a process of mapping and remapping business units to create a shifting mix of highly focused, tightly aligned businesses that can respond to changing market opportunities. Patching is not just another name for reorganizing; patchers have a distinctive mindset. Traditional managers see structure as stable; patching managers believe structure is inherently temporary. Traditional managers set corporate strategy first, but patching managers keep the organization focused on the right set of business opportunities and let strategy emerge from individual businesses. Although the focus of patching is flexibility, the process itself follows a pattern. Patching changes are usually small in scale and made frequently. Patching should be done quickly; the emphasis is on getting the patch about right and fixing problems later. Patches should have a test drive before they're formalized but then be tightly scripted after they've been announced. And patching won't work without the right infrastructure: modular business units, fine-grained and complete unit-level metrics, and companywide compensation parity. The authors illustrate how patching works and point out some common stumbling blocks.

  8. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012

    DEFF Research Database (Denmark)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A

    2015-01-01

    BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data of patie......BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data...... of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. RESULTS......: Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance...

  9. Evaluation of Nickel Allergic Reactions to the Essure Micro Insert: Theoretical Risk or Daily Practice?

    Science.gov (United States)

    Siemons, Sara; Vleugels, Michel; van Eijndhoven, Hugo

    2017-01-01

    To evaluate whether de novo development of nickel sensitization is related to placement of the Essure device, and to evaluate whether the grade of reaction to nickel increased after device placement in patients with a confirmed nickel allergy. Prospective cohort study (Canadian Task Force classification II-2). Two nonacademic training hospitals in The Netherlands. Healthy women of childbearing age desiring permanent sterilization. At least 72 hours before Essure sterilization, each patient received 2 patches, 1 patch with a nickel solution in 5% petrolatum and 1 control patch. In addition, the patient was asked to complete a questionnaire on allergy-related symptoms. The patch test was scored according to the criteria for contact dermatitis of Devos and Van Der Valk. At 3 months after Essure sterilization, the patch test and the questionnaire were repeated. All 169 patients underwent Essure sterilization and completed the patch test cycle. There were no statistically significant changes in patch test results and allergy-related symptoms after sterilization. Before sterilization, 29% of the patients had a positive patch test and 1.8% also showed a positive reaction to the control patch. Only 20.7% of the patients had a history of allergic reactions to nickel. After sterilization, 29% had a positive patch test and 0.6% also showed a positive reaction to the control patch. Among the patients with a positive patch test before sterilization, the grade of reaction did not increase after sterilization. Moreover, these patients did not exhibit any increase in allergy-related symptoms. Among 4 patients with a previous negative patch test, 2 developed a grade 1 reaction and 2 developed a grade 2 reaction after sterilization. Two of these 4 patients had a history of allergic reactions to nickel before sterilization despite a negative patch test. After sterilization, these 4 patients exhibited no increase in allergy-related symptoms. There were no statistically significant

  10. Nicotine patches improve mood and response speed in a lexical decision task.

    Science.gov (United States)

    Gentry, M V; Hammersley, J J; Hale, C R; Nuwer, P K; Meliska, C J

    2000-01-01

    The effects of smoking a cigarette or wearing a transdermal nicotine patch on mood and lexical decision-making were tested in eight smokers. Each participant was tested after 4 hours of smoking abstinence, under 4 conditions: placebo (very low nicotine) cigarette, nicotine cigarette, placebo patch, and nicotine patch. Relative to placebo, wearing the nicotine patch reduced Profile of Mood States (POMS) Total Mood Disturbance and Fatigue/Inertia scores, while increasing the speed of some types of lexical decisions. Smoking a nicotine cigarette did not affect reaction times, but unexpectedly decreased the accuracy of Word/ Nonword lexical decisions. Thus, transdermal nicotine may improve mood and facilitate longterm memory search and/or attentional processes in nicotine-deprived smokers.

  11. Birth Control Patch

    Science.gov (United States)

    ... Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Birth Control Patch KidsHealth / For Teens / Birth Control Patch What's ...

  12. Reaction times to weak test lights. [psychophysics biological model

    Science.gov (United States)

    Wandell, B. A.; Ahumada, P.; Welsh, D.

    1984-01-01

    Maloney and Wandell (1984) describe a model of the response of a single visual channel to weak test lights. The initial channel response is a linearly filtered version of the stimulus. The filter output is randomly sampled over time. Each time a sample occurs there is some probability increasing with the magnitude of the sampled response - that a discrete detection event is generated. Maloney and Wandell derive the statistics of the detection events. In this paper a test is conducted of the hypothesis that the reaction time responses to the presence of a weak test light are initiated at the first detection event. This makes it possible to extend the application of the model to lights that are slightly above threshold, but still within the linear operating range of the visual system. A parameter-free prediction of the model proposed by Maloney and Wandell for lights detected by this statistic is tested. The data are in agreement with the prediction.

  13. Sleep Sleeping Patch

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The Sleep Sleeping Patch is a new kind of external patch based on modern sleep medicine research achievements, which uses the internationally advanced transdermal therapeutic system (TTS). The Sleep Sleeping Patch transmits natural sleep inducers such as peppermint and liquorice extracts and melatonin through the skin to induce sleep. Clinical research proves that the Sleep Sleeping Patch can effectively improve insomnia and the quality of sleep. Highly effective: With the modern TTS therapy,

  14. Parametric effects on glass reaction in the unsaturated test method

    International Nuclear Information System (INIS)

    Woodland, A.B.; Bates, J.K.; Gerding, T.J.

    1991-12-01

    The Unsaturated Test Method has been applied to study glass reaction under conditions that may be present at the potential Yucca Mountain site, currently under evaluation for storage of reprocessed high-level nuclear waste. The results from five separate sets of parametric experiments are presented wherein test parameters ranging from water contact volume to sensitization of metal in contact with the glass were examined. The most significant effect was observed when the volume of water, as controlled by the water inject volume and interval period, was such to allow exfoliation of reacted glass to occur. The extent of reaction was also influenced to a lesser extent by the degree of sensitization of the 304L stainless steel. For each experiment, the release of cations from the glass and alteration of the glass were examined. The major alteration product is a smectite clay that forms both from precipitation from solution and from in-situ alteration of the glass itself. It is this clay that undergoes exfoliation as water drips from the glass. A comparison is made between the results of the parametric experiments with those of static leach tests. In the static tests the rates of release become progressively reduced through 39 weeks while, in contrast, they remain relatively constant in the parametric experiments for at least 300 weeks. This differing behavior may be attributable to the dripping water environment where fresh water is periodically added and where evaporation can occur

  15. PATIENTS' KNOWLEDGE OF MEDICAL PATCHES IN HUNGARY.

    Science.gov (United States)

    Somogyi, Orsolya; Zelko, Romana

    2016-11-01

    Transdermal therapy with medical patches is a simple possibility in home medication. As the correct use of patches has a decisive impact from the point of its modulator effect.A questionnaire survey was developed to explore level of patients' knowledge of the correct use of transdermal patches. A survey was administered in thirteen Hungarian community pharmacies from October of 2012 to May of 2015. Most of the participants, men and women over 18 years of age (n = 233), used major analgesic patches (fentanyl); the remainder were given nitroglycerin, NSAID analgesics patches during the survey. For the hypothesis testing it was assumed that men were more likely to use a razor for skin depilation before patch application than women as their denser pelage hinders patch adhesion. The hypothesis testing showed no significant gender difference in razor use (X² = 0.201; p = 0.654). Pharmacists should direct patients to avoid using soap for skin cleansing before patch application because only 22 percent of the participants always avoided its use. Since only 9 tests were flawless from 233 completed questionnaires. Many patients do not understand how to correctly apply a transdermal dosage patch. Pharmacists should teach their correct application based on results.

  16. A detailed test of the statistical theory of nuclear reactions

    NARCIS (Netherlands)

    Spijkervet, Andreas Lambertus

    1978-01-01

    Low-energy nuclear reactions are governed by two principal kinds of mechanisms: direct reaction mechanisms characterized by reaction times of the order of the transit time of the bombarding particle through the nucleus , and compound nucelar reaction mechanisms. The reaction times ot the latter are

  17. The diagnostic accuracy of the atopy patch test in diagnosing hypersensitivity to cow's milk and hen's egg in unselected children with and without atopic dermatitis

    DEFF Research Database (Denmark)

    Osterballe, Morten; Andersen, Klaus E; Bindslev-Jensen, Carsten

    2004-01-01

    BACKGROUND: Previous studies have suggested that the atopy patch test (APT) may make oral challenge superfluous in diagnosing children with food hypersensitivity. OBJECTIVE: To investigate the clinical relevance of APT in predicting hypersensitivity to cow's milk and hen's egg in 486 unselected...... children 3 years of age. METHOD: The children were examined by APT, skin prick (SPT), histamine release (HR), and specific IgE followed by oral challenge when hypersensitivity to cow's milk or hen's egg was suspected. RESULTS: Food hypersensitivity confirmed by oral challenge was 1.6% to hen's egg and 0.......6% to cow's milk. No hypersensitivity to cow's milk or hen's egg was predicted by APT alone. CONCLUSION: APT could not predict food hypersensitivity not predicted by SPT, HR, or specific IgE. Thus, APT cannot be recommended in daily practice for the diagnosis of hypersensitivity to cow's milk and hen's egg...

  18. Avaliação do teste de contato com aeroalérgenos em pacientes com dermatite atópica Evaluation of patch test with airbone allergic agents in patients with atopic dermatitis

    Directory of Open Access Journals (Sweden)

    Rosana Neves Dos Santos Rodrigues

    2011-02-01

    Full Text Available FUNDAMENTOS: a dermatite atópica é uma doença inflamatória cutânea que apresenta múltiplos fatores desencadeantes. Há vários relatos de autores que confirmaram os aeroalérgenos como fatores agravantes ou desencadeantes. O teste de contato com aeroalérgenos ou teste de contato atópico foi proposto para avaliar a participação destes alérgenos na dermatite atópica. OBJETIVO: objetivo deste estudo foi avaliar a positividade do teste de contato atópico em pacientes com dermatite atópica. MÉTODOS: Avaliamos 50 pacientes com dermatite atópica e 45 do grupo com rinite alérgica, nos quais realizamos teste de contato atópico com extratos de Dermatophagoides pteronissynus, Dermatophagoides farinae e Blomia tropicalis, além de testes cutâneos de leitura imediata para os mesmos alérgenos, acrescidos de epitélio de cão e gato e fungos. RESULTADOS: verificamos que o teste de contato atópico com ácaros apresentou maior positividade nos indivíduos do grupo de dermatite atópica quando comparado ao grupo de rinite alérgica. CONCLUSÕES: o teste de contato atópico apresenta resultados estatisticamente significativos quando realizado com ácaros, em pacientes com dermatite atópica, com p=0,035, OR (odds ratio = 3,35 e IC(95% = [ 1,18; 9,47].BACKGROUND: Atopic dermatitis is an inflammatory skin disease that can be triggered by many factors. Several reports confirm the role of airborne allergic agents as aggravating or triggering factors. The patch test with airborne allergic agents or the atopy patch test was suggested to evaluate the role of these allergens in atopic dermatitis. OBJECTIVE: This study aimed at evaluating the positivity of the atopy patch test in patients with atopic dermatitis. METHODS: We evaluated 50 patients with atopic dermatitis and 45 with allergic rhinitis, the atopy patch test was performed in these patiennts with extracts of Dermatophagoides pteronissynus, Dermatophagoides farinae and Blomia tropicalis, as

  19. Corridor Length and Patch Colonization by a Butterfly Junonia coenia

    Energy Technology Data Exchange (ETDEWEB)

    Nick Haddad

    2000-06-01

    Habitat corridors have been proposed to reduce patch isolation and increase population persistence in fragmented landscapes. This study tested whether patch colonization was increased by the presence and various length corridors. The specific butterfly species tested has been shown to use corridors, however, the results indicate that neither the distance between patches or the presence of a corridor influenced colonization.

  20. Test results of sodium-water reaction testing in near prototypical LMR steam generator

    International Nuclear Information System (INIS)

    Boardman, C.E.; Hui, M.; Neely, H.H.

    1990-01-01

    An extensive test program has been performed in the United States to investigate the effects of large sodium-water reaction events in LMFBR steam generators. Tests were conducted in the Large Leak Test Rig (LLTR) located at the Energy Technology Engineering Center (ETEC). The program was divided into two phases, Series I and Series II, for the purpose of satisfying near-term and long-term needs. Series II was further subdivided into large and intermediate leak tests. This paper will emphasize the Series II intermediate leak tests and resulting conclusions for steam generator design and operation. 11 figs, 2 tabs

  1. Patch testing with 2.0% (0.60 mg/cm2) formaldehyde instead of 1.0% (0.30 mg/cm2) detects significantly more contact allerg

    DEFF Research Database (Denmark)

    Pontén, Ann; Aalto-Korte, Kristiina; Agner, Tove

    2013-01-01

    .To validate earlier patch test results for comparison of 1% (wt/vol) and 2% (wt/vol) formaldehyde in water, and to investigate co-reactivity with quaternium-15. Materials and methods.In 12 dermatology clinics, 3591 patients were routinely patch tested simultaneously with 2.0% (wt/vol) (0.60 mg/cm(2) ) and 1.......0% (wt/vol) (0.30 mg/cm(2) ) formaldehyde. Micropipettes were used for delivering the exact dosage of the allergen. Results.Significantly more patients reacted to 2.0% formaldehyde than to 1.0% (3.4% versus 1.8%, p

  2. Development and characterization of mucoadhesive buccal patches of salbutamol sulphate.

    Science.gov (United States)

    Patel, Rajesh Singh; Poddar, S S

    2009-01-01

    Mucoadhesive patch releasing the drug in the oral cavity at predetermined rate may present distinct advantages over traditional dosage forms such as tablets, gels and solutions. The present study was concerned with the preparation and evaluation of mucoadhesive buccal patches for the controlled systemic delivery of Salbutamol sulphate to avoid first pass hepatic metabolism. The developed patches were evaluated for the physicochemical, mechanical and drug release characteristics. The patches showed desired mechanical and physicochemical properties to withstand environment of oral cavity. The in-vitro release study showed that patches could deliver drug to the oral mucosa for a period of 7 h. the patches exhibited adequate stability when tested under accelerated conditions.

  3. Preparation and evaluation of cosmetic patches containing lactic and glycolic acids

    Directory of Open Access Journals (Sweden)

    Mahdavi H

    2006-01-01

    Full Text Available Background: Alpha-hydroxy acids such as glycolic acid (GA and lactic acid (LA, are used in cosmetic patches. The important fact in cosmetic patches is its suitable adhesion and peel properties. Aim: The objective of this study was to prepare LA- and GA-containing cosmetic patches and evaluate in-vitro/in-vivo correlation of adhesion properties. Methods: Pressure-sensitive adhesives with different concentrations of GA and LA were cast on a polyethylene terephthalate film. The patches were evaluated for peel adhesive strength. On the basis of in vitro adhesion properties the patches were selected for wear performance tests and skin irritation potential. Results: The adhesion properties (adhesion to steel plate and skin and cohesive strength tests indicated the substantial influence of GA and LA concentrations. Based on in vitro adhesion studies the patches containing 3% (w/w GA were selected for in vivo studies. In vivo studies show that a formulation containing 3% GA displays good adhesion on the skin, but it leaves little residues on the skin. Skin Irritation studies on healthy human volunteers showed negligible erythema at the site of application after 48h. Conclusion: The noninvasive patch test model was found useful for detecting irritant skin reactions to the cosmetic patch containing GA. Our results demonstrated a strong correlation between the adhesion to steel plate and adhesion to skin. But a weak correlation between the degree of adhesive residue on the skin in in vitro and in vivo tests was observed for the formulation containing 3% (w/w GA.

  4. Recommendation to include fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) in the European baseline patch test series

    DEFF Research Database (Denmark)

    Bruze, Magnus; Andersen, Klaus Ejner; Goossens, An

    2008-01-01

    various European centres when tested in consecutive dermatitis patients. CONCLUSIONS: From 2008, pet. preparations of fragrance mix 2 at 14% w/w (5.6 mg/cm(2)) and hydroxyisohexyl 3-cyclohexene carboxaldehyde at 5% w/w (2.0 mg/cm(2)) are recommended for inclusion in the baseline series. With the Finn...

  5. Granisetron Transdermal Patch

    Science.gov (United States)

    Granisetron transdermal patches are used to prevent nausea and vomiting caused by chemotherapy. Granisetron is in a class of medications called 5HT3 ... Granisetron transdermal comes as a patch to apply to the skin. It is usually applied 24 to ...

  6. Estradiol Transdermal Patch

    Science.gov (United States)

    ... menopause (change of life; the end of monthly menstrual periods). Transdermal estradiol is also used to prevent ... patch. Ask your pharmacist or doctor for a copy of the manufacturer's information for the patient.

  7. Fentanyl Transdermal Patch

    Science.gov (United States)

    Fentanyl patches are used to relieve severe pain in people who are expected to need pain medication ... and who cannot be treated with other medications. Fentanyl is in a class of medications called opiate ( ...

  8. Selegiline Transdermal Patch

    Science.gov (United States)

    ... patch from direct heat such as heating pads, electric blankets, heat lamps, saunas, hot tubs, and heated ... may make you drowsy. Do not drive a car or operate machinery until you know how this ...

  9. Testosterone Transdermal Patch

    Science.gov (United States)

    ... one else can use it accidentally or on purpose. Keep track of how many patches are left ... to your pharmacist or contact your local garbage/recycling department to learn about take-back programs in ...

  10. Rotigotine Transdermal Patch

    Science.gov (United States)

    ... physical activity. If the edges of the patch lift, use a bandage tape to re-secure it ... burns on your skin if you are having magnetic resonance imaging (MRI; a radiology technique designed to ...

  11. Methylphenidate Transdermal Patch

    Science.gov (United States)

    ... for ADHD, which may include counseling and special education. Make sure to follow all of your doctor's ... that was covered by the patch seizures motion tics or verbal tics believing things that are not ...

  12. Windows Security patch required

    CERN Multimedia

    3004-01-01

    This concerns Windows PCs (XP, 2000, NT) which are NOT centrally managed at CERN for security patches, e.g. home PCs, experiment PCs, portables,... A security hole which can give full privileges on Windows systems needs to be URGENTLY patched. Details of the security hole and hotfix are at: http://cern.ch/it-div/news/hotfix-MS03-026.asp http://www.microsoft.com/technet/security/bulletin/MS03-026.asp

  13. The reaction index and positivity ratio revisited

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Andersen, Flemming

    2008-01-01

    BACKGROUND AND OBJECTIVES: Assessing the quality of patch test preparations continues to be a challenge. 2 parameters, the reaction index (RI) and positivity ratio (PR), have been proposed as quality indicators by the Information Network of Departments of Dermatology (IVDK). The value of these st......BACKGROUND AND OBJECTIVES: Assessing the quality of patch test preparations continues to be a challenge. 2 parameters, the reaction index (RI) and positivity ratio (PR), have been proposed as quality indicators by the Information Network of Departments of Dermatology (IVDK). The value...

  14. Chemical Characterization and Reactivity Testing of Fuel-Oxidizer Reaction Product (Test Report)

    Science.gov (United States)

    1996-01-01

    The product of incomplete reaction of monomethylhydrazine (MMH) and nitrogen tetroxide (NTO) propellants, or fuel-oxidizer reaction product (FORP), has been hypothesized as a contributory cause of an anomaly which occurred in the chamber pressure (PC) transducer tube on the Reaction Control Subsystem (RCS) aft thruster 467 on flight STS-51. A small hole was found in the titanium-alloy PC tube at the first bend below the pressure transducer. It was surmised that the hole may have been caused by heat and pressure resulting from ignition of FORP. The NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) was requested to define the chemical characteristics of FORP, characterize its reactivity, and simulate the events in a controlled environment which may have lead to the Pc-tube failure. Samples of FORP were obtained from the gas-phase reaction of MMH with NTO under laboratory conditions, the pulsed firings of RCS thrusters with modified PC tubes using varied oxidizer or fuel lead times, and the nominal RCS thruster firings at WSTF and Kaiser-Marquardt. Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), accelerating rate calorimetry (ARC), ion chromatography (IC), inductively coupled plasma (ICP) spectrometry, thermogravimetric analysis (TGA) coupled to FTIR (TGA/FTIR), and mechanical impact testing were used to qualitatively and quantitatively characterize the chemical, thermal, and ignition properties of FORP. These studies showed that the composition of FORP is variable but falls within a limited range of compositions that depends on the fuel loxidizer ratio at the time of formation, composition of the post-formation atmosphere (reducing or oxidizing), and reaction or postreaction temperature. A typical composition contains methylhydrazinium nitrate (MMHN), ammonium nitrate (AN), methylammonium nitrate (MAN), and trace amounts of hydrazinium nitrate and 1,1-dimethylhydrazinium nitrate. The thermal decomposition

  15. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    Science.gov (United States)

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  16. Atopy patch test (APT in the diagnosis of food allergy in children with atopic dermatitis Teste de contato atópico (TCA no diagnóstico de alergia alimentar em crianças com dermatite atópica

    Directory of Open Access Journals (Sweden)

    Soloni Afra Pires Levy

    2012-10-01

    Full Text Available BACKGROUND: Atopic Dermatitis is a chronic inflammatory skin disease. Food allergens are important in the pathogenesis in 1/3 of the cases. Several mechanisms are involved in the pathogenesis of Atopic Dermatitis. Immediate reactions are identified by both measurement of specific IgE and skin prick test. Atopy Patch Test seems to be relevant in the investigation of patients with suspected delayed-type reactions. OBJECTIVES: To evaluate the standardization of this method concerning allergen concentration, occlusion time and interpretation, and determine the specificity and sensitivity of the Atopy Patch Test according to the skin prick test and specific IgE levels in food allergy diagnosis in children with Atopic Dermatitis. METHODS: Seventy-two children, aged 2-12 years were selected and followed at the allergy clinic of the Hospital São Zacharias. Skin prick test, specific IgE and food Atopy Patch Test (cow's milk, egg, soy and wheat were carried out. Three groups were submitted to the Atopy Patch Test: (1 Atopic Dermatitis with or without Rhinitis and Asthma; (2 Rhinitis and or Asthma without AD; (3 Healthy individuals. RESULTS: In group 1, 40% of the patients presented positive reactions. The longer the exposure time (48h and 72h, the higher the sensitivity. In group 2, the test was more specific than sensitive for all the extracts, with increased sensitivity the longer the time of exposure (72h. In group 3, 8.3% presented positive tests. CONCLUSION: APT evidenced a great diagnostic value in late-phase reactions to food, with high specificity. It showed to be a specific and reliable tool in comparison with the healthy group's results.FUNDAMENTOS: A Dermatite Atópica é uma doença inflamatória crônica da pele. Os alimentos são importantes na patogênese da doença em 1/3 dos casos. Diversos mecanismos estão envolvidos na fisiopatogenia da dermatite Atópica. As reações imediatas são identificadas pela dosagem de IgE específica e

  17. Adenosine-loaded dissolving microneedle patches to improve skin wrinkles, dermal density, elasticity and hydration.

    Science.gov (United States)

    Kang, G; Tu, T N T; Kim, S; Yang, H; Jang, M; Jo, D; Ryu, J; Baek, J; Jung, H

    2018-04-01

    Although dissolving microneedle patches have been widely studied in the cosmetics field, no comparisons have been drawn with the topical applications available for routine use. In this study, two wrinkle-improving products, adenosine-loaded dissolving microneedle patches and an adenosine cream, were evaluated for efficacy, with respect to skin wrinkling, dermal density, elasticity, and hydration, and safety in a clinical test on the crow's feet area. Clinical efficacy and safety tests were performed for 10 weeks on 22 female subjects with wrinkles around their eyes. The adenosine-loaded dissolving microneedle patch was applied once every 3 days, in the evening, for 8 weeks to the designated crow's feet area. The adenosine cream was applied two times per day, in the morning and evening, for 8 weeks to the other crow's feet area. Skin wrinkling, dermal density, elasticity, and hydration were measured by using PRIMOS ® premium, Dermascan ® C, Cutometer ® MPA580, and Corneometer ® CM 825, respectively. In addition, subjective skin irritation was evaluated by self-observation, and objective skin irritation was assessed through expert interviews. The adenosine-loaded dissolving microneedle patches had a similar or better efficacy than the adenosine cream. Both groups showed statistically significant efficacy for almost all parameters (P hydration efficacy (P skin-improvement parameters, adenosine-loaded dissolving microneedle patches showed the same or better effect than the adenosine cream, although the weekly adenosine dose was 140 times lower. The dissolving microneedle patches caused no adverse reactions. These adenosine-loaded dissolving microneedle patches are expected to be safe, effective, and novel cosmetics for skin improvement. © 2018 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  18. Generic patch inference

    DEFF Research Database (Denmark)

    Andersen, Jesper; Lawall, Julia

    2010-01-01

    A key issue in maintaining Linux device drivers is the need to keep them up to date with respect to evolutions in Linux internal libraries. Currently, there is little tool support for performing and documenting such changes. In this paper we present a tool, spdiff, that identifies common changes...... developers can use it to extract an abstract representation of the set of changes that others have made. Our experiments on recent changes in Linux show that the inferred generic patches are more concise than the corresponding patches found in commits to the Linux source tree while being safe with respect...

  19. Test analysis and research on static choice reaction ability of commercial vehicle drivers

    Science.gov (United States)

    Zhang, Lingchao; Wei, Lang; Qiao, Jie; Tian, Shun; Wang, Shengchang

    2017-03-01

    Drivers' choice reaction ability has a certain relation with safe driving. It has important significance to research its influence on traffic safety. Firstly, the paper uses a choice reaction detector developed by research group to detect drivers' choice reaction ability of commercial vehicles, and gets 2641 effective samples. Then by using mathematical statistics method, the paper founds that average reaction time from accident group has no difference with non-accident group, and then introduces a variance rate of reaction time as a new index to replace it. The result shows that the test index choice reaction errors and variance rate of reaction time have positive correlations with accidents. Finally, according to testing results of the detector, the paper formulates a detection threshold with four levels for helping transportation companies to assess commercial vehicles drivers.

  20. The local lymph node assay compared with the human maximization test as an indicator of allergic potency in humans using patch test clinic populations.

    Science.gov (United States)

    Zaghi, Danny; Maibach, Howard I

    2009-01-01

    The human maximization test (HMT) is a method to evaluate potency in humans, while the local lymph node assay (LLNA) is a test method that allows for the measuring of the allergic potency of a substance in a rodent. It has been proposed that an EC3 value (the value obtained by the LLNA test, ie, the concentration of an allergen leading to a 3-fold increase of baseline proliferation rate) would be a reliable indicator for a compound's allergic potency in humans. This paper compares the correlation between the EC3 value of a compound and its allergic occurrence in the general population with the correlation between the HMT of the compound and its allergic occurrence in the general population, to determine the relationship to potency. The correlation values when outliers were removed from the sample were -0.56 and -0.71 for LLNA and HMT, respectively, suggesting that there is a possible 20% error margin in LLNA's ability to predict potency. The data also suggest that other factors (such as exposure) could play up to a 30% role in the determination of allergic occurrence in the general population. The potency assays might be made more clinically relevant for predicting allergic frequencies by including a frequency factor and other factors in its dermatotoxicological interpretation.

  1. Spin-selective recombination reactions of radical pairs: Experimental test of validity of reaction operators

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Kiminori [Department of Chemistry, University of Oxford, Centre for Advanced Electron Spin Resonance, Inorganic Chemistry Laboratory, Oxford (United Kingdom); Liddell, Paul; Gust, Devens [Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona, 85287-1604 (United States); Hore, P. J. [Department of Chemistry, University of Oxford, Physical and Theoretical Chemistry Laboratory, Oxford (United Kingdom)

    2013-12-21

    Spin-selective reactions of radical pairs are conventionally modelled using an approach that dates back to the 1970s [R. Haberkorn, Mol. Phys. 32, 1491 (1976)]. An alternative approach based on the theory of quantum measurements has recently been suggested [J. A. Jones and P. J. Hore, Chem. Phys. Lett. 488, 90 (2010)]. We present here the first experimental attempt to discriminate between the two models. Pulsed electron paramagnetic resonance spectroscopy has been used to investigate intramolecular electron transfer in the radical pair form of a carotenoid-porphyrin-fullerene molecular triad. The rate of spin-spin relaxation of the fullerene radical in the triad was found to be inconsistent with the quantum measurement description of the spin-selective kinetics, and in accord with the conventional model when combined with spin-dephasing caused by rotational modulation of the anisotropic g-tensor of the fullerene radical.

  2. Reaction time in Stroop test in Nepalese Medical Students

    OpenAIRE

    Ghimire, Nisha; Paudel, Bishnu Hari; Khadka, Rita; Singh, P. N.

    2014-01-01

    Background: Stroop test is one of the widely used tests in cognitive psychology. It is used both in healthy population and also in patients to assess the selective attention. The selective attention as assessed by it is also found to be altered in bilinguals. In Nepal, most of the students are bilingual since most of the courses are in English language. Thus, they learn English language along with their native languages. This study is aimed to assess the selective attention in healthy Nepales...

  3. QCD tests and large momentum-transfer reactions at CBA

    International Nuclear Information System (INIS)

    Longacre, R.; Tannenbaum, M.J.

    1983-03-01

    It is desirable to try to find fundamental tests of QCD which are sensitive to the specific properties of gluons and the non-Alelian structure of the theory, which would show that the theory is computable above leading order, and which are insensitive to the extraneous parameters such as structure functions, fragmentation functions and the like. Such tests can occur when higher-order corrections produce interference effects which must be zero in lowest order. One such effect is the linear polarization of direct single photons produced in p-p collisions. It is claimed that this polarization provides a rigorous test of perturbative QCD as well as an important check on the color hypothesis. This latter aspect is particularly attractive because the polarization involves the three-gluon interaction and the equality of the quark-gluon and three-gluon coupling in an essential way. Plans for studies at the CBA are discussed

  4. Testing quantum chromodynamics in anti-proton reactions

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1987-10-01

    An experimental program with anti-protons at intermediate energy can serve as an important testing ground for QCD. Detailed predictions for exclusive cross sections at large momentum transfer based on perturbative QCD and the QCD sum rule form of the proton distribution amplitude are available for anti p p → γγ for both real and virtual photons. Meson-pair and lepton-pair final states also give sensitive tests of the theory. The production of charmed hadrons in exclusive anti p p channels may have a non-negligible cross section. Anti-proton interactions in a nucleus, particularly J/psi production, can play an important role in clarifying fundamental QCD issues, such as color transparency, critical length phenomena, and the validity of the reduced nuclear amplitude phenomenology

  5. Reaction

    African Journals Online (AJOL)

    abp

    19 oct. 2017 ... Reaction to Mohamed Said Nakhli et al. concerning the article: "When the axillary block remains the only alternative in a 5 year old child". .... Bertini L1, Savoia G, De Nicola A, Ivani G, Gravino E, Albani A et al ... 2010;7(2):101-.

  6. Full-course drug challenge test in the diagnosis of delayed allergic reactions to penicillin.

    Science.gov (United States)

    Borch, Jakob E; Bindslev-Jensen, Carsten

    2011-01-01

    Drug challenge test (DCT) has long been the most sensitive test in the allergological work-up when investigating for penicillin allergy. To improve sensitivity of the diagnostic work-up in diagnosing penicillin allergics with histories of allergic reactions on day 2 or later in the course of penicillin treatment. A full-course DCT was added to the current protocol if specific IgE, skin tests and DCT were all negative in patients who had a nonimmediate reaction to penicillin treatment. Sixteen patients with a history of an immediate reaction to penicillin treatment underwent testing with negative outcomes. Fifty percent of patients undergoing full-course DCT experienced a cutaneous adverse drug reaction. None of the controls reacted (p = 0.001). The mean time of reaction was 6 days. Penicillin V accounted for most reactions. Urticaria was the most frequent clinical reaction observed. Full-course DCT offers an improvement of sensitivity and predictive values of the diagnostic work-up of allergic reactions to penicillin occurring on day 2 of penicillin treatment or later. Copyright © 2011 S. Karger AG, Basel.

  7. The incidence and features of systemic reactions to skin prick tests.

    Science.gov (United States)

    Sellaturay, Priya; Nasser, Shuaib; Ewan, Pamela

    2015-09-01

    Skin prick testing (SPT) has been regarded as a safe procedure with few systemic reactions. To evaluate the rate of systemic reactions and their associations after SPT in the largest population to date. In this study reactions were recorded prospectively in a specialist UK allergy clinic for 6 years (2007-2013). An estimated 31,000 patients underwent SPT. Twenty-four patients (age range 7 months to 56 years, mean 23.5 years, 17 female patients, 12 with asthma) had systemic reactions. The rate of systemic reactions to SPT was 0.077%. The likely allergens causing the reaction were foods (18; peanut, 7; walnut, 1; Brazil nut, 2; pistachio, 1; lupin, 1; cow's milk, 2; shrimp, 1; spinach, 1; legume, 1; soy, 1), aeroallergens (4; rabbit, 1; rat, 1; ragwort, 1; grass pollen, 1), wasp venom (1), and Tazocin (1). The causative SPT wheal was larger than 8 mm in 75%. The reaction to Tazocin was severe, with anaphylaxis occurring minutes after SPT. Reactions were treated immediately in the clinic and did not require further medical care. In this largest single-center study, the rate of systemic reactions after SPT was 77 per 100,000 patients. It is the first study to identify foods as a common and important cause (75%), with nuts posing the highest risk. This study reports the first systemic reaction to venom SPT and the first anaphylactic reaction after drug SPT. There was an association with a history of severe reactions and large skin test reaction. There are risks, albeit small, when undertaking SPT. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  8. Effectiveness of lidocaine Denti patch ® system versus lidocaine gel as topical anesthetic agent in children

    Directory of Open Access Journals (Sweden)

    Lara Anwar Shehab

    2015-01-01

    Full Text Available Background: New methods have been introduced to facilitate dental procedures, but the administration of local anesthesia is still necessary to perform pain control during several dental procedures. Aim: To evaluate the effectiveness of the lidocaine Denti-patch ® system versus the lidocaine topical anesthetic gel in children concerning pain reaction during injection. Materials and Methods: One hundred 9-12-year-old cooperative children weighing more than 29 kg in need of bilateral dental treatment requiring maxillary and mandibular injection and not suffering from acute pain as a result of pulpits on the day of treatment were selected. The children were then divided into two groups: Group 1 comprising of 50 children in need of bilateral maxillary treatment and Group 2 compromising of 50 children requiring bilateral mandibular treatment. These groups were further subdivided into subgroups A and B; those receiving Denti-patch ® on one side and lidocaine gel on the contralateral side, respectively. Pain or comfort was evaluated during injection using sound, eye, motor (SEM scale (objective method while, using faces pain rating scale (FPS scale (subjective method after injection by a trained assistant blinded to the procedure. Statistical Analysis Used: Comparison of the results was performed using Mann-Whitney U-test and Wilcoxon signed-ranks test for SEM and FPS score. Result: There was a statistically significant difference between the patch and the gel group for maxilla (P < 0.0001, as well as mandible (P = 0.01 with respect to SEM score given by the children. Similarly, with FPS scale, there was a statistically significant difference between the patch and the gel groups in both maxilla and mandible (P < 0.0001. However, there was no statistical difference between the patch Groups 1A and IIA or the gel Groups 1B and II B. Conclusion: The Denti-patch ® system can significantly reduce the needle injection pain more than the gel.

  9. Outline of sodium-water reaction test in case of large leak with SWAT-3 testing equipments

    International Nuclear Information System (INIS)

    Sato, Minoru

    1978-01-01

    The key component in sodium-cooled fast reactors in steam generators, and the sodium-water reaction owing to the break of heating tubes may cause serious damages in equipments and pipings. The main factor controlling this phenomenon is the rate of leak of water. When the rate of water leak is small, the propagation of heating tube breaking may occur owing to ''wastage phenomenon'', on the other hand, when the rate of water leak is large, the phenomena of explosive pressure and flow occur due to the reaction heat and a large quantity of hydrogen generated by the reaction. In PNC, the testing equipments of SWAT-2 for small water leak and SWAT-1 for large leak were constructed, and the development test has been carried out to establish the method of safety design experimentally. The synthetic test equipment for the safety of steam generators, SWAT-3, was constructed to carry out the large water leak test in the scale close to actual plants. The object of the test, the outline of the test equipment, the phenomena of pressure and flow in the water injection test, the confirmation of the occurrence of secondary breaking of adjacent heating tubes, and the disposal of reaction products are described in this paper. This test is till going on, and the final conclusion will be reported later. (Kako, I.)

  10. Rabies vaccination in dogs using a dissolving microneedle patch.

    Science.gov (United States)

    Arya, Jaya M; Dewitt, Kristopher; Scott-Garrard, Maya; Chiang, Yu-Wei; Prausnitz, Mark R

    2016-10-10

    Because humans get rabies primarily through dog bites, stray dog population control and mass or mandatory vaccination of domestic dogs and other animals has virtually eliminated human rabies in industrialized countries. However, thousands of people in developing countries die of rabies each year due to the inability to control dog populations and implement mass vaccination because of financial, logistical and other challenges. The availability of an easier-to-administer and more cost-effective vaccine may help to address some of these issues. Here, we propose the use of dissolving microneedle patches for simple and potentially cost-effective rabies vaccination, and assess the safety and immunogenicity of microneedle patch vaccination using a rabies DNA vaccine in dogs. The vaccine was stable upon formulation and storage for at least 3weeks at 4°C in a microneedle patch. For vaccination, the patches were applied to the inner ear by hand without an applicator. Microneedle patches were well tolerated in the skin, with mild erythema, minimal wheal formation and complete resolution of skin reactions within 7days, and generated no systemic adverse events. Microneedle patches were at least as immunogenic as intramuscular injection at the same dose, as demonstrated by similar serum neutralizing antibody titers. A ten-fold lower vaccine dose administered by microneedle patch generated a weaker immune response compared to full-dose intramuscular vaccination. We conclude that dissolving microneedle patches may provide an innovative approach to mass vaccination of dogs. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Results and code prediction comparisons of lithium-air reaction and aerosol behavior tests

    International Nuclear Information System (INIS)

    Jeppson, D.W.

    1986-03-01

    The Hanford Engineering Development Laboratory (HEDL) Fusion Safety Support Studies include evaluation of potential safety and environmental concerns associated with the use of liquid lithium as a breeder and coolant for fusion reactors. Potential mechanisms for volatilization and transport of radioactive metallic species associated with breeder materials are of particular interest. Liquid lithium pool-air reaction and aerosol behavior tests were conducted with lithium masses up to 100 kg within the 850-m 3 containment vessel in the Containment Systems Test Facility. Lithium-air reaction rates, aerosol generation rates, aerosol behavior and characterization, as well as containment atmosphere temperature and pressure responses were determined. Pool-air reaction and aerosol behavior test results were compared with computer code calculations for reaction rates, containment atmosphere response, and aerosol behavior. The volatility of potentially radioactive metallic species from a lithium pool-air reaction was measured. The response of various aerosol detectors to the aerosol generated was determined. Liquid lithium spray tests in air and in nitrogen atmospheres were conducted with lithium temperatures of about 427 0 and 650 0 C. Lithium reaction rates, containment atmosphere response, and aerosol generation and characterization were determined for these spray tests

  12. Preparation of Mucoadhesive Patches for Buccal Administration of ...

    African Journals Online (AJOL)

    Purpose: To develop mucoadhesive patches for buccal administration of metoprolol succinate and to evaluate their in vitro and in vivo bioadhesion. Methods: The mucoadhesive buccal patches were prepared by solvent casting technique using two different mucoadhesive polymers. The formulations were tested for in vitro ...

  13. Emergent properties of patch shapes affect edge permeability to animals.

    Directory of Open Access Journals (Sweden)

    Vilis O Nams

    Full Text Available Animal travel between habitat patches affects populations, communities and ecosystems. There are three levels of organization of edge properties, and each of these can affect animals. At the lowest level are the different habitats on each side of an edge, then there is the edge itself, and finally, at the highest level of organization, is the geometry or structure of the edge. This study used computer simulations to (1 find out whether effects of edge shapes on animal behavior can arise as emergent properties solely due to reactions to edges in general, without the animals reacting to the shapes of the edges, and to (2 generate predictions to allow field and experimental studies to test mechanisms of edge shape response. Individual animals were modeled traveling inside a habitat patch that had different kinds of edge shapes (convex, concave and straight. When animals responded edges of patches, this created an emergent property of responding to the shape of the edge. The response was mostly to absolute width of the shapes, and not the narrowness of them. When animals were attracted to edges, then they tended to collect in convexities and disperse from concavities, and the opposite happened when animals avoided edges. Most of the responses occurred within a distance of 40% of the perceptual range from the tip of the shapes. Predictions were produced for directionality at various locations and combinations of treatments, to be used for testing edge behavior mechanisms. These results suggest that edge shapes tend to either concentrate or disperse animals, simply because the animals are either attracted to or avoid edges, with an effect as great as 3 times the normal density. Thus edge shape could affect processes like pollination, seed predation and dispersal and predator abundance.

  14. Five different tests of reaction time evaluated in HIV seropositive men.

    Science.gov (United States)

    Dunlop, O; Bjørklund, R A; Abdelnoor, M; Myrvang, B

    1992-09-01

    In an attempt to develop a short neuropsychological test battery five different tests of reaction time were assessed according to their ability to discriminate between HIV seropositive men and healthy controls. In all tests a patient group with clinical symptoms was slower than the control group. In the complex reaction time test, which has a large cognitive aspect, even a clinically "asymptomatic" group was slower than the control group. The movement test, a new test with a large motor component, identified most slow responders, defining approximately half of the patients with clinical symptoms and one third of the "asymptomatic" patients as such. A test battery consisting of three tests is suggested for serial assessment and screening.

  15. Polymerase chain reaction and conventional DNA tests in detection of HPV DNA in cytologically normal and abnormal cervical scrapes

    DEFF Research Database (Denmark)

    Kalia, A.; Jalava, T.; Nieminen, P.

    1992-01-01

    Med.mikrobiologi, polymerase chain reaction, DNA tests, human papillomavirus (HPV), cervical smear, hybridisation, cytologi, affiProbe HPV test, ViraType test......Med.mikrobiologi, polymerase chain reaction, DNA tests, human papillomavirus (HPV), cervical smear, hybridisation, cytologi, affiProbe HPV test, ViraType test...

  16. Definition of simulated driving tests for the evaluation of drivers' reactions and responses.

    Science.gov (United States)

    Bartolozzi, Riccardo; Frendo, Francesco

    2014-01-01

    This article aims at identifying the most significant measures in 2 perception-response (PR) tests performed at a driving simulator: a braking test and a lateral skid test, which were developed in this work. Forty-eight subjects (26 females and 22 males) with a mean age of 24.9 ± 3.0 years were enrolled for this study. They were asked to perform a drive on the driving simulator at the University of Pisa (Italy) following a specific test protocol, including 8-10 braking tests and 8-10 lateral skid tests. Driver input signals and vehicle model signals were recorded during the drives and analyzed to extract measures such as the reaction time, first response time, etc. Following a statistical procedure (based on analysis of variance [ANOVA] and post hoc tests), all test measures (3 for the braking test and 8 for the lateral skid test) were analyzed in terms of statistically significant differences among different drivers. The presented procedure allows evaluation of the capability of a given test to distinguish among different drivers. In the braking test, the reaction time showed a high dispersion among single drivers, leading to just 4.8 percent of statistically significant driver pairs (using the Games-Howell post hoc test), whereas the pedal transition time scored 31.9 percent. In the lateral skid test, 28.5 percent of the 2 × 2 comparisons showed significantly different reaction times, 19.5 percent had different response times, 35.2 percent had a different second peak of the steering wheel signal, and 33 percent showed different values of the integral of the steering wheel signal. For the braking test, which has been widely employed in similar forms in the literature, it was shown how the reaction time, with respect to the pedal transition time, can have a higher dispersion due to the influence of external factors. For the lateral skid test, the following measures were identified as the most significant for application studies: the reaction time for the reaction

  17. Patch testing with fragrances: results of a multicenter study of the European Environmental and Contact Dermatitis Research Group with 48 frequently used constituents of perfumes

    DEFF Research Database (Denmark)

    Frosch, P J; Pilz, B; Andersen, Klaus Ejner

    1995-01-01

    ), citronellol (1) and amyl salicylate (1)). The remaining 41 fragrances were negative. 28 irritant or doubtful reactions on day 3/4 were observed to a total of 19 FF materials (more than 1 reaction: 5% citronellol (2), 1% amyl salicylate (2), 1% isononyl acetate (3), 0.1% musk xylol (2), 1% citral (2), and 1...

  18. Pharmacokinetic Evaluation of Two Nicotine Patches in Smokers.

    Science.gov (United States)

    Rasmussen, Scott; Horkan, Kathleen Halabuk; Kotler, Mitchell

    2018-02-02

    Smoking continues to be a major preventable cause of early mortality worldwide, and nicotine replacement therapy has been demonstrated to increase rates of abstinence among smokers attempting to quit. Nicotine transdermal systems (also known as nicotine patches) attach to the skin via an adhesive layer composed of a mixture of different-molecular-weight polyisobutylenes (PIBs) in a specific ratio. This randomized, single-dose, 2-treatment, crossover pharmacokinetic (PK) trial assessed the bioequivalence of nicotine patches including a replacement PIB adhesive (test) compared with the PIB adhesive historically used on marketed patches (reference). The test and reference patches were bioequivalent, as determined by the PK parameters of C max and AUC 0-t . In addition, the parameters T max and t 1/2 did not significantly differ between the 2 patches, supporting the bioequivalence finding from the primary analysis. The tolerability profiles of the patches containing the replacement and previously used PIB adhesives were similar; application-site adverse events did not significantly differ between test and reference patches. Overall, these data establish the bioequivalence of the nicotine patch with the replacement PIB adhesive formulation and the previously utilized PIB adhesive formulation. © 2018 The Authors. Clinical Pharmacology in Drug Development published by Wiley Periodicals, Inc. on behalf of The American College of Clinical Pharmacology.

  19. Nonlinear reaction-diffusion equations with delay: some theorems, test problems, exact and numerical solutions

    Science.gov (United States)

    Polyanin, A. D.; Sorokin, V. G.

    2017-12-01

    The paper deals with nonlinear reaction-diffusion equations with one or several delays. We formulate theorems that allow constructing exact solutions for some classes of these equations, which depend on several arbitrary functions. Examples of application of these theorems for obtaining new exact solutions in elementary functions are provided. We state basic principles of construction, selection, and use of test problems for nonlinear partial differential equations with delay. Some test problems which can be suitable for estimating accuracy of approximate analytical and numerical methods of solving reaction-diffusion equations with delay are presented. Some examples of numerical solutions of nonlinear test problems with delay are considered.

  20. Corynebacterium renale as a cause of reactions to the complement fixation test for Johne's disease

    NARCIS (Netherlands)

    Gilmour, N.J.L.; Goudswaard, J.

    Complement fixation (C.F.) tests and fluorescent antibody (F.A.) tests were carried out on sera from rabbits inoculated with Corynebacterium renale and Mycobacterium johnei, and on sera from cattle with C. renale pyelonephritis and with Johne's disease. Cross-reactions were a feature of the C.F.

  1. Method optimization of ocular patches

    Directory of Open Access Journals (Sweden)

    Kamalesh Upreti

    2012-01-01

    Full Text Available The intraocular patches were prepared using gelatin as the polymer. Ocular patch were prepared by solvent casting method. The patches were prepared for six formulations GP1, GP2, GP3, GP4, GP5 and GP6. Petri dishes were used for formulation of ocular patch. Gelatin was used as a polymer of choice. Glutaraldehyde used as cross linking agent and (DMSO dimethylsulfoxide used as solubility enhancer. The elasticity depends upon the concentration of gelatin. 400 mg amount of polymer i.e gelatin gave the required elasticity for the formulation.

  2. Occupational Contact Dermatitis in North American Print Machine Operators Referred for Patch Testing: Retrospective Analysis of Cross-Sectional Data From the North American Contact Dermatitis Group 1998 to 2014.

    Science.gov (United States)

    Warshaw, Erin M; Hagen, Solveig L; Belsito, Donald V; DeKoven, Joel G; Maibach, Howard I; Mathias, C G Toby; Zug, Kathryn A; Sasseville, Denis; Zirwas, Matthew J; Fowler, Joseph F; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Taylor, James S

    Little is known about the epidemiology of contact dermatitis (CD) in print machine operators (PMOs). The aims of this study were to estimate the prevalence of CD and characterize clinically relevant and occupationally related allergens among PMOs undergoing patch testing. This was a retrospective cross-sectional analysis of the North American Contact Dermatitis Group data from 1998 to 2014. Of 39,332 patch-tested patients, 132 (0.3%) were PMOs. Among PMOs, most were male (75.0%) and white (92.4%). The majority were printing press operators (85.6%). The most frequent sites of dermatitis were hands (63.6%), arms (29.5%), and face/scalp (24.2%). More than half had an occupationally related skin condition (56.1%). Final diagnoses were most commonly allergic CD (58.3%) and irritant CD (33.3%). Cobalt (20.8%), carba mix (12.5%), thiuram mix (8.3%), and formaldehyde (8.3%) were the most frequent occupationally related allergens. The top allergen sources included inks (22.9%), gloves (20.8%), and coatings/dye/copy/photographic chemicals (14.6%). Allergic CD, irritant CD, and involvement of exposed body areas were common among PMOs. Common allergens included rubber accelerators, metals, and preservatives.

  3. Occupational Contact Dermatitis in North American Production Workers Referred for Patch Testing: Retrospective Analysis of Cross-Sectional Data From the North American Contact Dermatitis Group 1998 to 2014.

    Science.gov (United States)

    Warshaw, Erin M; Hagen, Solveig L; DeKoven, Joel G; Zug, Kathryn A; Sasseville, Denis; Belsito, Donald V; Zirwas, Matthew J; Fowler, Joseph F; Taylor, James S; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Maibach, Howard I; Mathias, C G Toby

    Little is known about the epidemiology of contact dermatitis in production workers (PWs). The aims of this study were to estimate the prevalence of contact dermatitis and characterize clinically relevant and occupationally related allergens among North American PWs undergoing patch testing. This was a retrospective cross-sectional analysis of North American Contact Dermatitis Group data from 1998 to 2014. Of 39,332 patch-tested patients, 2732 (7.0%) were PWs. Among PWs, most were men (62.4%) and white (83.9%). A history of childhood eczema was uncommon (11.3%). Prevalent occupations included machine operators (27.3%); fabricators, assemblers, and hand-working occupations (16.8%); and precision metalworking occupations (16.1%). The most frequent sites of dermatitis were the hands (53.8%) and arms (29.4%), which were significantly more commonly affected compared with non-PWs (P contact dermatitis, and irritant contact dermatitis were also significantly more common in PWs (49.9% vs 10.6%, 58.9% vs 53.7%, and 32.7% vs 25.7%, respectively; all Ps contact dermatitis. Involvement of exposed body areas was common. Frequently identified allergens included adhesives/glues, rubber accelerators, metals, and preservatives.

  4. A novel approach to sports concussion assessment: Computerized multilimb reaction times and balance control testing.

    Science.gov (United States)

    Vartiainen, Matti V; Holm, Anu; Lukander, Jani; Lukander, Kristian; Koskinen, Sanna; Bornstein, Robert; Hokkanen, Laura

    2016-01-01

    Mild traumatic brain injuries (MTBI) or concussions often result in problems with attention, executive functions, and motor control. For better identification of these diverse problems, novel approaches integrating tests of cognitive and motor functioning are needed. The aim was to characterize minor changes in motor and cognitive performance after sports-related concussions with a novel test battery, including balance tests and a computerized multilimb reaction time test. The cognitive demands of the battery gradually increase from a simple stimulus response to a complex task requiring executive attention. A total of 113 male ice hockey players (mean age = 24.6 years, SD = 5.7) were assessed before a season. During the season, nine concussed players were retested within 36 hours, four to six days after the concussion, and after the season. A control group of seven nonconcussed players from the same pool of players with comparable demographics were retested after the season. Performance was measured using a balance test and the Motor Cognitive Test battery (MotCoTe) with multilimb responses in simple reaction, choice reaction, inhibition, and conflict resolution conditions. The performance of the concussed group declined at the postconcussion assessment compared to both the baseline measurement and the nonconcussed controls. Significant changes were observed in the concussed group for the multilimb choice reaction and inhibition tests. Tapping and balance showed a similar trend, but no statistically significant difference in performance. In sports-related concussions, complex motor tests can be valuable additions in assessing the outcome and recovery. In the current study, using subtasks with varying cognitive demands, it was shown that while simple motor performance was largely unaffected, the more complex tasks induced impaired reaction times for the concussed subjects. The increased reaction times may reflect the disruption of complex and integrative cognitive

  5. Simplified method of ''push-pull'' test data analysis for determining in situ reaction rate coefficients

    International Nuclear Information System (INIS)

    Haggerty, R.; Schroth, M.H.; Istok, J.D.

    1998-01-01

    The single-well, ''''push-pull'''' test method is useful for obtaining information on a wide variety of aquifer physical, chemical, and microbiological characteristics. A push-pull test consists of the pulse-type injection of a prepared test solution into a single monitoring well followed by the extraction of the test solution/ground water mixture from the same well. The test solution contains a conservative tracer and one or more reactants selected to investigate a particular process. During the extraction phase, the concentrations of tracer, reactants, and possible reaction products are measured to obtain breakthrough curves for all solutes. This paper presents a simplified method of data analysis that can be used to estimate a first-order reaction rate coefficient from these breakthrough curves. Rate coefficients are obtained by fitting a regression line to a plot of normalized concentrations versus elapsed time, requiring no knowledge of aquifer porosity, dispersivity, or hydraulic conductivity. A semi-analytical solution to the advective-dispersion equation is derived and used in a sensitivity analysis to evaluate the ability of the simplified method to estimate reaction rate coefficients in simulated push-pull tests in a homogeneous, confined aquifer with a fully-penetrating injection/extraction well and varying porosity, dispersivity, test duration, and reaction rate. A numerical flow and transport code (SUTRA) is used to evaluate the ability of the simplified method to estimate reaction rate coefficients in simulated push-pull tests in a heterogeneous, unconfined aquifer with a partially penetrating well. In all cases the simplified method provides accurate estimates of reaction rate coefficients; estimation errors ranged from 0.1 to 8.9% with most errors less than 5%

  6. Negativization rates of IgE radioimmunoassay and basophil activation test in immediate reactions to penicillins.

    Science.gov (United States)

    Fernández, T D; Torres, M J; Blanca-López, N; Rodríguez-Bada, J L; Gomez, E; Canto, G; Mayorga, C; Blanca, M

    2009-02-01

    Skin test sensitivity in patients with immediate allergy to penicillins tends to decrease over time, but no information is available concerning in vitro tests. We analysed the negativization rates of two in vitro methods that determine specific immunoglobulin E (IgE) antibodies, the basophil activation test using flow cytometry (BAT) and the radioallergosorbent test (RAST), in immediate allergic reactions to penicillins. Forty-one patients with immediate allergic reactions to amoxicillin were followed up over a 4-year period. BAT and RAST were performed at 6-month intervals. Patients were randomized into groups: Group I, skin tests carried out at regular intervals; Group II, skin tests made only at the beginning of the study. Differences were observed between RAST and BAT (P testing influenced the rate of negativization of the RAST assay, contributing to maintenance of in vitro sensitivity. Because of the loss of sensitivity over time, the determination of specific IgE antibodies to penicillins in patients with immediate allergic reactions must be done as soon as possible after the reaction.

  7. Planar patch clamp: advances in electrophysiology.

    Science.gov (United States)

    Brüggemann, Andrea; Farre, Cecilia; Haarmann, Claudia; Haythornthwaite, Ali; Kreir, Mohamed; Stoelzle, Sonja; George, Michael; Fertig, Niels

    2008-01-01

    Ion channels have gained increased interest as therapeutic targets over recent years, since a growing number of human and animal diseases have been attributed to defects in ion channel function. Potassium channels are the largest and most diverse family of ion channels. Pharmaceutical agents such as Glibenclamide, an inhibitor of K(ATP) channel activity which promotes insulin release, have been successfully sold on the market for many years. So far, only a small group of the known ion channels have been addressed as potential drug targets. The functional testing of drugs on these ion channels has always been the bottleneck in the development of these types of pharmaceutical compounds.New generations of automated patch clamp screening platforms allow a higher throughput for drug testing and widen this bottleneck. Due to their planar chip design not only is a higher throughput achieved, but new applications have also become possible. One of the advantages of planar patch clamp is the possibility of perfusing the intracellular side of the membrane during a patch clamp experiment in the whole-cell configuration. Furthermore, the extracellular membrane remains accessible for compound application during the experiment.Internal perfusion can be used not only for patch clamp experiments with cell membranes, but also for those with artificial lipid bilayers. In this chapter we describe how internal perfusion can be applied to potassium channels expressed in Jurkat cells, and to Gramicidin channels reconstituted in a lipid bilayer.

  8. Do candidate reactions relate to job performance or affect criterion-related validity? A multistudy investigation of relations among reactions, selection test scores, and job performance.

    Science.gov (United States)

    McCarthy, Julie M; Van Iddekinge, Chad H; Lievens, Filip; Kung, Mei-Chuan; Sinar, Evan F; Campion, Michael A

    2013-09-01

    Considerable evidence suggests that how candidates react to selection procedures can affect their test performance and their attitudes toward the hiring organization (e.g., recommending the firm to others). However, very few studies of candidate reactions have examined one of the outcomes organizations care most about: job performance. We attempt to address this gap by developing and testing a conceptual framework that delineates whether and how candidate reactions might influence job performance. We accomplish this objective using data from 4 studies (total N = 6,480), 6 selection procedures (personality tests, job knowledge tests, cognitive ability tests, work samples, situational judgment tests, and a selection inventory), 5 key candidate reactions (anxiety, motivation, belief in tests, self-efficacy, and procedural justice), 2 contexts (industry and education), 3 continents (North America, South America, and Europe), 2 study designs (predictive and concurrent), and 4 occupational areas (medical, sales, customer service, and technological). Consistent with previous research, candidate reactions were related to test scores, and test scores were related to job performance. Further, there was some evidence that reactions affected performance indirectly through their influence on test scores. Finally, in no cases did candidate reactions affect the prediction of job performance by increasing or decreasing the criterion-related validity of test scores. Implications of these findings and avenues for future research are discussed. PsycINFO Database Record (c) 2013 APA, all rights reserved

  9. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reactions 46Ti(n,p) 46Sc + 47Ti(n, np)46Sc. Note 1—Since the cross section for the (n,np) reaction is relatively small for energies less than 12 MeV and is not easily distinguished from that of the (n,p) reaction, this test method will refer to the (n,p) reaction only. 1.2 The reaction is useful for measuring neutrons with energies above approximately 4.4 MeV and for irradiation times up to about 250 days (for longer irradiations, see Practice E 261). 1.3 With suitable techniques, fission-neutron fluence rates above 109 cm–2·s–1 can be determined. However, in the presence of a high thermal-neutron fluence rate, 46Sc depletion should be investigated. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all...

  10. Waterhammer modeling for the Ares I Upper Stage Reaction Control System cold flow development test article

    Science.gov (United States)

    Williams, Jonathan Hunter

    The Upper Stage Reaction Control System provides in-flight three-axis attitude control for the Ares I Upper Stage. The system design must accommodate rapid thruster firing to maintain proper launch trajectory and thus allow for the possibility to pulse multiple thrusters simultaneously. Rapid thruster valve closure creates an increase in static pressure, known as waterhammer, which propagates throughout the propellant system at pressures exceeding nominal design values. A series of development tests conducted at Marshall Space Flight Center in 2009 were performed using a water-flow test article to better understand fluid characteristics of the Upper Stage Reaction Control System. A subset of the tests examined the waterhammer pressure and frequency response in the flight-representative system and provided data to anchor numerical models. This thesis presents a comparison of waterhammer test results with numerical model and analytical results. An overview of the flight system, test article, modeling and analysis are also provided.

  11. Analgesic Microneedle Patch for Neuropathic Pain Therapy.

    Science.gov (United States)

    Xie, Xi; Pascual, Conrado; Lieu, Christopher; Oh, Seajin; Wang, Ji; Zou, Bende; Xie, Julian; Li, Zhaohui; Xie, James; Yeomans, David C; Wu, Mei X; Xie, Xinmin Simon

    2017-01-24

    Neuropathic pain caused by nerve injury is debilitating and difficult to treat. Current systemic pharmacological therapeutics for neuropathic pain produce limited pain relief and have undesirable side effects, while current local anesthetics tend to nonspecifically block both sensory and motor functions. Calcitonin gene related peptide (CGRP), a neuropeptide released from sensory nerve endings, appears to play a significant role in chronic neuropathic pain. In this study, an analgesic microneedle (AMN) patch was developed using dissolvable microneedles to transdermally deliver selective CGRP antagonist peptide in a painless manner for the treatment of localized neuropathic pain. Local analgesic effects were evaluated in rats by testing behavioral pain sensitivity in response to thermal and mechanical stimuli using neuropathic pain models such as spared-nerve injury and diabetic neuropathy pain, as well as neurogenic inflammatory pain model induced by ultraviolet B (UVB) radiation. Unlike several conventional therapies, the AMN patches produced effective analgesia on neuropathic pain without disturbing the normal nociception and motor function of the rat, resulting from the high specificity of the delivered peptide against CGRP receptors. The AMN patches did not cause skin irritation or systemic side effects. These results demonstrate that dissolvable microneedle patches delivering CGRP antagonist peptide provide an effective, safe, and simple approach to mitigate neuropathic pain with significant advantages over current treatments.

  12. Test of distorted wave kinematic coupling approximation calculations for knockout reactions

    International Nuclear Information System (INIS)

    Jain, A.K.

    1990-01-01

    A test has been devised to check the validity of conventional distorted-wave impulse approximation (DWIA) treatment of knockout reactions. The conventional DWIA formalism separates the three-body final state Schroedinger equation for a knockout reaction into two two-body Schroedinger equations by assuming an asymptotic constant value for the three-body coupling term commonly known as the kinematic coupling approximation (KCA). In the test case, which consists of an extreme asymmetric situation where one of the distorting optical potentials is assumed to vanish, the three-body final state Schroedinger equation can be solved exactly as a product of two two-body solutions using one particular set of relative coordinates. Large influence of the three-body coupling term is seen in the comparison of the exact and KCA results for (α,2α) and (p,pα) knockout reactions when the distorting optical potentials are weakly absorbing

  13. Intermediate-scale sodium-concrete reaction tests with basalt and limestone concrete

    International Nuclear Information System (INIS)

    Hassberger, J.A.; Muhlestein, L.D.

    1981-01-01

    Ten tests were performed to investigate the chemical reactions and rate and extent of attack between sodium and basalt and limestone concretes. Test temperatures ranged from 510 to 870 0 C (950 to 1600 0 F) and test times from 2 to 24 hours. Sodium hydroxide was added to some of the tests to assess the impact of a sodium hydroxide-aided reaction on the overall penetration characteristics. Data suggest that the sodium penetration of concrete surfaces is limited. Penetration of basalt concrete in the presence of sodium hydroxide is shown to be less severe than attack by the metallic sodium alone. Presence of sodium hydroxide changes the characteristics of sodium penetration of limestone concrete, but no major differences in bulk penetration were observed as compared to penetration by metallic sodium

  14. Application of reaction type of C-peptide release test in diabetes mellitus

    International Nuclear Information System (INIS)

    Chen Dong; Duan Wenruo; He Juan; Lu Zhenfang

    2001-01-01

    The author is to confirm the effect of C-peptide release test and types of release reaction in appraisal of pancreas function of β-cell and selection of treatment for diabetes mellitus (DM) patients. The serum C-peptide release test of 67 normal controls and 217 DM patients were determined by RIA, and the results were analyzed and compared. C-peptide release test can reflect the pancreas function of β-cell better, the peak of C-peptide ≥ 0.6 nmol/L after lunch can be the limit of whether to reduce the level of blood glucose only by oral drug. The authors should adjust the treatment through analyzing the type of C-peptide release reaction. C-peptide release test is very important in evaluating the pancreas function of β-cell, classifying the type of DM and selecting the treatment

  15. Empirical Investigation of Job Applicants' Reactions to Taking a Pre-Employment Honesty Test.

    Science.gov (United States)

    Jones, John W.; Joy, Dennis

    Employee theft is widespread and difficult to detect. Many companies have attempted to control the employee theft problem through pre-employment screening. The use of paper-and-pencil honesty tests in this process has become increasingly common. These two studies empirically investigated job applicants' (N=450) reactions to taking a pre-employment…

  16. Optimisation of Forensic Genetics Procedures Used in Disputed Paternity Testing: Adjustment of the PCR Reaction Volume

    Directory of Open Access Journals (Sweden)

    Damir Marjanović

    2006-05-01

    Full Text Available Standard molecular techniques, with only a slight modification, are very useful in obtaining and interpreting the final results in the field of forensic genetic. Data obtained through such analysis are highly reliable and can be used as a very powerful tool that produces valuable results. However, success and swiftness of DNA typing of biological evidence either that found at a crime scene or used in disputed paternity testing, depends on the optimization of numerous factors. One of the most important and critical phases that ensures reliability of the whole procedure is the choice of the most suitable volume for the amplification protocol. Buccal swabs were collected from volunteers. DNA was extracted by Qiagen Dnaeasy Tissue Kit. PowerPlex 16 kit was used to simultaneously amplify 15 STR loci by PCR. Amplification was carried out as described previously. The tested total working reaction volumes were 5, 10 and 25 microl. The PCR amplification was carried out in PE Gene Amp PCR System Thermal Cycler (ABI, Foster City, CA. Amplification products were analyzed on an ABI PRISM 377 instrument (ABI, Foster City, CA in 5% bis-acrilamide gel. Amplification was generally successful for all the tested reaction volumes. Lower partial to complete DNA profiles ratio, the quality of obtained STR profiles, significantly reduced amount of reaction's components give advantage to 5 microl reaction volume over other two tested volumes in this case.

  17. Large scale sodium-water reaction tests for Monju steam generators

    International Nuclear Information System (INIS)

    Sato, M.; Hiroi, H.; Hori, M.

    1976-01-01

    To demonstrate the safe design of the steam generator system of the prototype fast reactor Monju against the postulated large leak sodium-water reaction, a large scale test facility SWAT-3 was constructed. SWAT-3 is a 1/2.5 scale model of the Monju secondary loop on the basis of the iso-velocity modeling. Two tests have been conducted in SWAT-3 since its construction. The test items using SWAT-3 are discussed, and the description of the facility and the test results are presented

  18. Edge of polar cap patches

    Science.gov (United States)

    Hosokawa, K.; Taguchi, S.; Ogawa, Y.

    2016-04-01

    On the night of 4 December 2013, a sequence of polar cap patches was captured by an all-sky airglow imager (ASI) in Longyearbyen, Norway (78.1°N, 15.5°E). The 630.0 nm airglow images from the ASI of 4 second exposure time, oversampled the emission of natural lifetime (with quenching) of at least ˜30 sec, introduce no observational blurring effects. By using such high-quality ASI images, we succeeded in visualizing an asymmetry in the gradients between the leading/trailing edges of the patches in a 2-D fashion. The gradient in the leading edge was found to be 2-3 times steeper than that in the trailing edge. We also identified fingerlike structures, appearing only along the trailing edge of the patches, whose horizontal scale size ranged from 55 to 210 km. These fingers are considered to be manifestations of plasma structuring through the gradient-drift instability (GDI), which is known to occur only along the trailing edge of patches. That is, the current 2-D observations visualized, for the first time, how GDI stirs the patch plasma and such a mixing process makes the trailing edge more gradual. This result strongly implies a close connection between the GDI-driven plasma stirring and the asymmetry in the large-scale shape of patches and then suggests that the fingerlike structures can be used as markers to estimate the fine-scale structure in the plasma flow within patches.

  19. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Niobium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes procedures for measuring reaction rates by the activation reaction 93Nb(n,n′)93mNb. 1.2 This activation reaction is useful for monitoring neutrons with energies above approximately 0.5 MeV and for irradiation times up to about 30 years. 1.3 With suitable techniques, fast-neutron reaction rates for neutrons with energy distribution similar to fission neutrons can be determined in fast-neutron fluences above about 1016cm−2. In the presence of high thermal-neutron fluence rates (>1012cm−2·s−1), the transmutation of 93mNb due to neutron capture should be investigated. In the presence of high-energy neutron spectra such as are associated with fusion and spallation sources, the transmutation of 93mNb by reactions such as (n,2n) may occur and should be investigated. 1.4 Procedures for other fast-neutron monitors are referenced in Practice E 261. 1.5 Fast-neutron fluence rates can be determined from the reaction rates provided that the appropriate cross section information ...

  20. *New* CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  1. *New*: CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  2. Test Results for a Non-toxic, Dual Thrust Reaction Control Engine

    Science.gov (United States)

    Robinson, Philip J.; Veith, Eric M.; Turpin, Alicia A.

    2005-01-01

    A non-toxic, dual thrust reaction control engine (RCE) was successfully tested over a broad range of operating conditions at the Aerojet Sacramento facility. The RCE utilized LOX/Ethanol propellants; and was tested in steady state and pulsing modes at 25-lbf thrust (vernier) and at 870-lbf thrust (primary). Steady state vernier tests vaned chamber pressure (Pc) from 0.78 to 5.96 psia, and mixture ratio (MR) from 0.73 to 1.82, while primary steady state tests vaned Pc from 103 to 179 psia and MR from 1.33 to 1.76. Pulsing tests explored EPW from 0.080 to 10 seconds and DC from 5 to 50 percent at both thrust levels. Vernier testing accumulated a total of 6,670 seconds of firing time, and 7,215 pulses, and primary testing accumulated a total of 2,060 seconds of firing time and 3,646 pulses.

  3. Development of blow down and sodium-water reaction jet analysis codes-Validation by sodium-water reaction tests (SWAT-1R)

    International Nuclear Information System (INIS)

    Hiroshi Seino; Akikazu Kurihara; Isao Ono; Koji Jitsu

    2005-01-01

    Blow down analysis code (LEAP-BLOW) and sodium-water reaction jet analysis code (LEAP-JET) have been developed in order to improve the evaluation method on sodium-water reaction event in the steam generator (SG) of a sodium cooled fast breeder reactor (FBR). The validation analyses by these two codes were carried out using the data of Sodium-Water Reaction Test (SWAT-1R). The following main results have been obtained through this validation: (1) The calculational results by LEAP-BLOW such as internal pressure and water flow rate show good agreement with the results of the SWAT- 1R test. (2) The LEAP-JET code can qualitatively simulate the behavior of sodium-water reaction. However, it is found that the code has tendency to overestimate the maximum temperature of the reaction jet. (authors)

  4. Piper betle LEAVES EXTRACT PATCH: EVALUATION OF ANTIBACTERIAL ACTIVITY, RELEASE PROFILE OF EUGENOL, AND LOCAL TOLERANCE

    Directory of Open Access Journals (Sweden)

    Mufrod Mufrod

    2016-08-01

    Full Text Available Piper betle leaf in extract form is more effective than crude drug. Eugenol is a component in the extract that has antibacterial activity but irritate. Patch of piper betle leaf extract was used on the mucosa to make oral cavity hygiene. Antibacterial activity was influenced by the release of eugenol from the patch. Release enhancer substances (RES such as glycerin, propylen glicol and tween 80 were added in patch formulation to increase the release of active substances. The aim of the research was to investigate the physicochemical properties, eugenol release profiles, and local tolerance test of the patch. Extract of piper betle leaf was made using infundation method. Patch was made according to the variation concentration of extract (1, 2 and 4% and RES (glycerine, propylen glycol and tween 80 using chitosan as vehicle. Patch produced solvent casting method. Patch obtained was tested for swelling index, folding endurance, surface pH, antibacterial activity, release of eugenol, and local tolerance. Data obtained were analyzed descriptively. The result showed that the addition of RES did not affect the surface pH but increase the water absorption with in inconsistent way except patch with tween 80. The flexibility (folding endurance value increased, and the highest amount of eugenol released was achieved by patch using propylen glicol. Patch with tween 80 and glycerin for all extract concentration and patch with 1% extract concentration using propylen glycol showed medium sensation (local tolerance, and patch with 2 and 4% extract using propylen glycol showed severe sensation.

  5. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Aluminum

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers procedures measuring reaction rates by the activation reaction 27Al(n,α)24Na. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 6.5 MeV and for irradiation times up to about 2 days (for longer irradiations, see Practice E261). 1.3 With suitable techniques, fission-neutron fluence rates above 106 cm−2·s−1 can be determined. 1.4 Detailed procedures for other fast neutron detectors are referenced in Practice E261. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. DEA deformed stretchable patch antenna

    International Nuclear Information System (INIS)

    Jiang, X-J; Jalali Mazlouman, S; Menon, C; Mahanfar, A; Vaughan, R G

    2012-01-01

    A stretchable patch antenna (SPA) whose frequency is tuned by a planar dielectric elastomer actuator (DEA) is presented in this paper. This mechanically reconfigurable antenna system has a configuration resembling a pre-stretched silicone belt. Part of the belt is embedded with a layer of conductive liquid metal to form the patch antenna. Part of the belt is sandwiched between conductive electrodes to form the DEA. Electrical activation of the DEA results in a contraction of the patch antenna, and as a result, in a variation of its resonance frequency. Design and fabrication steps of this system are presented. Measurement results for deformation, resonance frequency variation and efficiency of the patch antenna are also presented. (paper)

  7. Minimal hepatic encephalopathy characterized by parallel use of the continuous reaction time and portosystemic encephalopathy tests

    DEFF Research Database (Denmark)

    Lauridsen, M M; Schaffalitzky de Muckadell, O B; Vilstrup, H

    2015-01-01

    Minimal hepatic encephalopathy (MHE) is a frequent complication to liver cirrhosis that causes poor quality of life, a great burden to caregivers, and can be treated. For diagnosis and grading the international guidelines recommend the use of psychometric tests of different modalities (computer...... based vs. paper and pencil). To compare results of the Continuous Reaction time (CRT) and the Portosystemic Encephalopathy (PSE) tests in a large unselected cohort of cirrhosis patients without clinically detectable brain impairment and to clinically characterize the patients according to their test...

  8. Using the accelerated Brazilian concrete prism test (ABCPT to evaluate alkali aggregate reaction (AAR

    Directory of Open Access Journals (Sweden)

    L. Sanchez

    Full Text Available There are many test methods used in the laboratory to detect potential alkali-aggregate reactions (AAR. However, up to now, there is no consensus if they are reliable and efficient. This work presents the development of a new and accelerated concrete prism test called ABCPT (accelerate Brazilian concrete prism test as an attempt to create a reliable and fast test that can analyze and classify the potential reactivity of aggregates in the laboratory. For this research, six aggregates from different lithotypes were used. The methods CPT, ACPT and ABCPT were carried out with all the aggregates and a comparative analysis among all tests was performed. ABCPT seems to have a great potential to analyze and classify aggregates in the laboratory, although it needs further testing with other lithotypes to be confirmed as feasible.

  9. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Copper

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reaction 63Cu(n,α)60Co. The cross section for 60Co produced in this reaction increases rapidly with neutrons having energies greater than about 5 MeV. 60Co decays with a half-life of 1925.27 days (±0.29 days)(1) and emits two gamma rays having energies of 1.1732278 and 1.332492 MeV (1). The isotopic content of natural copper is 69.17 % 63Cu and 30.83 % 65Cu (2). The neutron reaction, 63Cu(n,γ)64Cu, produces a radioactive product that emits gamma rays which might interfere with the counting of the 60Co gamma rays. 1.2 With suitable techniques, fission-neutron fluence rates above 109 cm−2·s−1 can be determined. The 63Cu(n,α)60Co reaction can be used to determine fast-neutron fluences for irradiation times up to about 15 years (for longer irradiations, see Practice E261). 1.3 Detailed procedures for other fast-neutron detectors are referenced in Practice E261. 1.4 This standard does not purport to address all of the...

  10. The Effects of Repeated Testing, Simulated Malingering, and Traumatic Brain Injury on Visual Choice Reaction Time

    Directory of Open Access Journals (Sweden)

    David L Woods

    2015-11-01

    Full Text Available Choice reaction time (CRT, the time required to discriminate and respond appropriately to different stimuli, is a basic measure of attention and processing speed. Here, we describe the reliability and clinical sensitivity of a new CRT test that presents lateralized visual stimuli and adaptively adjusts stimulus onset asynchronies (SOAs using a staircase procedure. Experiment 1 investigated the test-retest reliability in three test sessions at weekly intervals. Performance in the first test session was accurately predicted from age and computer-use regression functions obtained in a previously studied normative cohort. Central processing time (CentPT, the difference between the CRTs and simple reaction time latencies measured in a separate experiment, accounted for 55% of CRT latency and more than 50% of CRT latency variance. Performance improved significantly across the three test sessions. High intraclass correlation coefficients (ICCs were seen for CRTs (0.90, CentPTs (0.87, and an omnibus performance measure (0.81 that combined CRT and minimal SOA (mSOA z-scores. Experiment 2 investigated performance in the same participants when instructed to feign symptoms of traumatic brain injury (TBI: 87% produced abnormal omnibus z-scores. Simulated malingerers showed greater elevations in simple than choice reaction times, and hence reduced CentPTs. Latency-consistency z-scores, based on the difference between the CRTs obtained and those predicted from CentPT latencies, discriminated malingering participants from controls with high sensitivity and specificity. Experiment 3 investigated CRT test performance in military veterans who had suffered combat-related TBI and symptoms of post-traumatic stress disorder and revealed small but significant deficits in performance. The results indicate that the new CRT test shows high test-retest reliability, can assist in detecting participants performing with suboptimal effort, and is sensitive to the effects of

  11. International reactions after the resumption of nuclear tests: lot of noise for nothing?

    International Nuclear Information System (INIS)

    Montesquieu, E. de

    1996-01-01

    In 1995, the French President announced that France would perform an ultimate campaign of nuclear tests before a complete banishment as soon as spring 1996. The campaign effectively ended on time and six tests took place between September 5, 1995 and January 27, 1996. The disarmament process went on and the international negotiations in progress at that time were not affected by the French policy. However, this campaign has caused a strong emotion, if not in the entire World, at least in part of the planet and in particular in Western Europe. This report analyses the reactions from the different governments and from the public opinion and shows their impact on the French diplomacy. Content: Part 1 - general considerations: 1 - lot of noise for nothing?: the objectives of French diplomacy; the acts (a quasi lack of sanctions, a temporary degradation of our relations with a limited number of countries); the rhetoric (diplomatic regrets in first time, slip-ups in the second time, the public opinion weight); 2 - the lessons learnt: the opinion and the management of the foreign policy (the image of France, the communication fight); the geopolitical lessons (European Union: community solidarity and European defense; the South Pacific area); 3 - a case study: Japan: the time of uncertainties (domestic situation, external policy); the Japanese reactions after the tests resumption. Part 2 - synthesis of reactions after the resumption of nuclear tests by France: Pacific bordering countries (South Pacific, Latin America); Western Europe countries; non-European countries; Conclusions

  12. Standard Test Method for Measuring Reaction Rates by Analysis of Barium-140 From Fission Dosimeters

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes two procedures for the measurement of reaction rates by determining the amount of the fission product 140Ba produced by the non-threshold reactions 235U(n,f), 241Am(n,f), and 239Pu(n,f), and by the threshold reactions 238U(n,f), 237Np(n,f), and 232Th(n,f). 1.2 These reactions produce many fission products, among which is 140Ba, having a half-life of 12.752 days. 140Ba emits gamma rays of several energies; however, these are not easily detected in the presence of other fission products. Competing activity from other fission products requires that a chemical separation be employed or that the 140Ba activity be determined indirectly by counting its daughter product 140La. This test method describes both procedure (a), the nondestructive determination of 140Ba by the direct counting of 140La several days after irradiation, and procedure (b), the chemical separation of 140Ba and the subsequent counting of 140Ba or its daughter 140La. 1.3 With suitable techniques, fission neutron fl...

  13. Bilaterally Weighted Patches for Disparity Map Computation

    Directory of Open Access Journals (Sweden)

    Laura Fernández Julià

    2015-03-01

    Full Text Available Visual correspondence is the key for 3D reconstruction in binocular stereovision. Local methods perform block-matching to compute the disparity, or apparent motion, of pixels between images. The simplest approach computes the distance of patches, usually square windows, and assumes that all pixels in the patch have the same disparity. A prominent artifact of the method is the "foreground fattening effet" near depth discontinuities. In order to find a more appropriate support, Yoon and Kweon introduced the use of weights based on color similarity and spatial distance, analogous to those used in the bilateral filter. This paper presents the theory of this method and the implementation we have developed. Moreover, some variants are discussed and improvements are used in the final implementation. Several examples and tests are presented and the parameters and performance of the method are analyzed.

  14. Metamaterial Embedded Wearable Rectangular Microstrip Patch Antenna

    Directory of Open Access Journals (Sweden)

    J. G. Joshi

    2012-01-01

    Full Text Available This paper presents an indigenous low-cost metamaterial embedded wearable rectangular microstrip patch antenna using polyester substrate for IEEE 802.11a WLAN applications. The proposed antenna resonates at 5.10 GHz with a bandwidth and gain of 97 MHz and 4.92 dBi, respectively. The electrical size of this antenna is 0.254λ×0.5λ. The slots are cut in rectangular patch to reduce the bending effect. This leads to mismatch the impedance at WLAN frequency band; hence, a metamaterial square SRR is embedded inside the slot. A prototype antenna has been fabricated and tested, and the measured results are presented in this paper. The simulated and measured results of the proposed antenna are found to be in good agreement. The bending effect on the performance of this antenna is experimentally verified.

  15. Test plan for reactions between spent fuel and J-13 well water under unsaturated conditions

    International Nuclear Information System (INIS)

    Finn, P.A.; Wronkiewicz, D.J.; Hoh, J.C.; Emery, J.W.; Hafenrichter, L.D.; Bates, J.K.

    1993-01-01

    The Yucca Mountain Site Characterization Project is evaluating the long-term performance of a high-level nuclear waste form, spent fuel from commercial reactors. Permanent disposal of the spent fuel is possible in a potential repository to be located in the volcanic tuff beds near Yucca Mountain, Nevada. During the post-containment period the spent fuel could be exposed to water condensation since of the cladding is assumed to fail during this time. Spent fuel leach (SFL) tests are designed to simulate and monitor the release of radionuclides from the spent fuel under this condition. This Test Plan addresses the anticipated conditions whereby spent fuel is contacted by small amounts of water that trickle through the spent fuel container. Two complentary test plans are presented, one to examine the reaction of spent fuel and J-13 well water under unsaturated conditions and the second to examine the reaction of unirradiated UO 2 pellets and J-13 well water under unsaturated conditions. The former test plan examines the importance of the water content, the oxygen content as affected by radiolysis, the fuel burnup, fuel surface area, and temperature. The latter test plant examines the effect of the non-presence of Teflon in the test vessel

  16. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos

    2012-01-01

    The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in consecutiv...

  17. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    NARCIS (Netherlands)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos; Fernandez-Vozmediano, José M; Ayala, Fabio; Balato, Anna; Bauer, Andrea; Ballmer-Weber, Barbara; Beliauskiene, Aiste; Fortina, Anna Belloni; Bircher, Andreas; Brasch, Jochen; Chowdhury, Mahbub M U; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise; Cooper, Sue; Czarnecka-Operacz, Magda; Zmudzinska, Maria; Elsner, Peter; English, John S C; Frosch, Peter J; Fuchs, Thomas; García-Gavín, Juan; Fernández-Redondo, Virginia; Gawkrodger, David J; Giménez-Arnau, Ana; Green, Cathy M; Horne, Helen L; Johansen, Jeanne Duus; Jolanki, Riitta; Pesonen, Maria; King, Clodagh M; Krêcisz, Beata; Chomiczewska, Dorota; Kiec-Swierczynska, Marta; Larese, Francesca; Mahler, Vera; Ormerod, Anthony D; Peserico, Andrea; Rantanen, Tapio; Rustemeyer, Thomas; Sánchez-Pérez, Javier; Sansom, Jane E; Silvestre, Juan Fco; Simon, Dagmar; Spiewak, Radoslaw; Statham, Barry N; Stone, Natalie; Wilkinson, Mark; Schnuch, Axel

    BACKGROUND: The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in

  18. Visual and cognitive predictors of performance on brake reaction test: Salisbury eye evaluation driving study.

    Science.gov (United States)

    Zhang, Lei; Baldwin, Kevin; Munoz, Beatriz; Munro, Cynthia; Turano, Kathleen; Hassan, Shirin; Lyketsos, Constantine; Bandeen-Roche, Karen; West, Sheila K

    2007-01-01

    Concern for driving safety has prompted research into understanding factors related to performance. Brake reaction speed (BRS), the speed with which persons react to a sudden change in driving conditions, is a measure of performance. Our aim is to determine the visual, cognitive, and physical factors predicting BRS in a population sample of 1425 older drivers. The Maryland Department of Motor Vehicles roster of persons aged 67-87 and residing in Salisbury, MD, was used for recruitment of the study population. Procedures included the following: habitual, binocular visual acuity using ETDRS charts, contrast sensitivity using a Pelli-Robson chart, visual fields assessed with a 81-point screening Humphrey field at a single intensity threshold, and a questionnaire to ascertain medical conditions. Cognitive status was assessed using a standard battery of tests for attention, memory, visuo-spatial, and scanning. BRS was assessed using a computer-driven device that measured separately the initial reaction speed (IRS) (from light change to red until removing foot from accelerator) and physical response speed (PRS) (removing foot from accelerator to full brake depression). Five trial times were averaged, and time was converted to speed. The median brake reaction time varied from 384 to 5688 milliseconds. Age, gender, and cognition predicted total BRS, a non-informative result as there are two distinct parts to the task. Once separated, decrease in IRS was associated with low scores on cognitive factors and missing points on the visual field. A decrease in PRS was associated with having three or more physical complaints related to legs and feet, and poorer vision search. Vision was not related to PRS. We have demonstrated the importance of segregating the speeds for the two tasks involved in brake reaction. Only the IRS depends on vision. Persons in good physical condition may perform poorly on brake reaction tests if their vision or cognition is compromised.

  19. Postural reactions of girls and boys aged 12–15 years evaluated using the Romberg test

    Directory of Open Access Journals (Sweden)

    Jacek Wilczyński

    2016-07-01

    Full Text Available Introduction : The complex system controlling human posture includes a gaze stabilisation system, which comprises the control of direction and visual acuity during head and body movements, and a posture stabilisation system, keeping the body in balance at rest and in movement. Aim of the research: To analyse the postural reaction of SOX and SOY using the Romberg test with eyes open (EO and closed (CE in girls and boys aged 12–15 years. Material and methods : The study included 503 students of Primary School No. 13 and School No. 4 in Starachowice. Postural reactions were tested on a Cosmogamma platform by Emildue R50300. Postural reactions were analysed, and mean sway X (MSX and mean sway Y (MSY were calculated. Results: Analysis of variance showed significant differences of MSX only between girls and boys (p < 0.036. MSX was significantly lower in girls in both tests with EO and CE. Although there was no apparent significant difference of MSX between the Romberg test with EO and CE, a slight progression was observed in the test with CE. Analysis of variance of MSY with a single classification showed a significant effect of study options (p < 0.048, a significant interaction of gender and options of the study (p < 0.048, and a significant interaction of age and options of the study (p < 0.026. Analysis of variance of MSY showed a significant progression of MSY in the test with CE. Conclusions : Our research showed that balance with CE does not worsen, so it can be assumed that children have limited skills of using vision to maintain balance because there is a lack of appropriate coordination between vision and motor abilities, which in children are in development.

  20. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study

    DEFF Research Database (Denmark)

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan

    2011-01-01

    the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened...... most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0...

  1. Hypersensitivity reactions to penicillins: studies in a group of patients with negative benzylpenicillin G skin test.

    Science.gov (United States)

    Qiao, H-L; Li, Z; Yang, J; Tian, X; Gao, N; Jia, L-J

    2009-06-01

    Although skin tests are usually employed to evaluate current penicillin allergy status, a negative result does not exclude hypersensitivity. There is a need for accurate in vitro tests to exclude hypersensitivity. A radioallergosorbent test (RAST) is a potentially good supplementary approach, but there is little information on the suitability of this method to diagnose penicillin hypersensitivity in subjects with a negative skin test to benzylpenicillin. A total of 133 patients with a negative skin test to benzylpenicillin G (PG) and all of whom developed allergic reactions to PG were studied. RAST was used to detect eight kinds of specific IgE antibodies to penicillins in serum, which included four kinds of major and minor antigenic determinants to four penicillin drugs. The combination sites for the specific IgE antibodies were studied by RAST inhibition test. The rate of positive reactions for the specific IgE antibodies was 59.40% (79/133). Of the eight kinds of antigenic determinants, the positive rates for specific IgE against the major and minor determinants were 39.10% (52) and 42.86% (57) respectively. Of the four drugs, positive cases only to PG were 10 (7.5%), were significantly fewer than the cross-reacting positive cases (36) to PG (P penicillins could induce specific responses with a variable degree of cross-reactivity among the different penicillins. Radioallergosorbent test is a good complementary test in persons who are skin-test negative with PG, and the sensitivity of RAST increases with increasing specificity of IgE antibodies to be detected. 6-APA and the groups, making part of the different side-chains on penicillins, all contributed to the cross-reactivity.

  2. Systemic reaction after performing a food prick-to-prick test. A case report

    Directory of Open Access Journals (Sweden)

    Karen Estefanía Hernández-Moreno

    2017-02-01

    Full Text Available Background: Skin prick test is the most widely used test for the diagnosis of IgE-mediated conditions. Commercial extracts are used for its performance, but in the case of fruits and vegetables it is preferable using fresh food. Although both tests possess a good safety profile, hypersensitivity reactions have been recorded. Clinical case: Forty-seven-year old woman with a history of persistent allergic rhinitis, sensitized to the pollen of grasses, olive and salsola; she was referred to an allergology department due to anaphylaxis triggered by the consumption of avocado, cantaloupe, carrots and watermelon. Minutes after skin prick test with standardized extract and skin prick with fresh foods, she developed dyspnea, pruritus, erythema, dizziness and sibilance; she was administered 0.5 mg of intramuscular adrenalin and 4 salbutamol inhalations and placed in the Trendelemburg position. Dyspnea persisted, and vital signs monitoring showed heart and respiratory rates increase and, hence, salbutamol was applied again, together with 2 L/min of oxygen delivered by nasal cannula, intravenous fluids and 100 mg intravenous hydrocortisone; improvement was observed at 40 minutes. The patient was hospitalized for 48 hours. Conclusions: Although skin tests are safe, the risk of hypersensitivity and anaphylactic reactions should not be ruled out, especially in susceptible patients.

  3. Waterhammer Modeling for the Ares I Upper Stage Reaction Control System Cold Flow Development Test Article

    Science.gov (United States)

    Williams, Jonathan H.

    2010-01-01

    The Upper Stage Reaction Control System provides three-axis attitude control for the Ares I launch vehicle during active Upper Stage flight. The system design must accommodate rapid thruster firing to maintain the proper launch trajectory and thus allow for the possibility to pulse multiple thrusters simultaneously. Rapid thruster valve closure creates an increase in static pressure, known as waterhammer, which propagates throughout the propellant system at pressures exceeding nominal design values. A series of development tests conducted in the fall of 2009 at Marshall Space Flight Center were performed using a water-flow test article to better understand fluid performance characteristics of the Upper Stage Reaction Control System. A subset of the tests examined waterhammer along with the subsequent pressure and frequency response in the flight-representative system and provided data to anchor numerical models. This thesis presents a comparison of waterhammer test results with numerical model and analytical results. An overview of the flight system, test article, modeling and analysis are also provided.

  4. Development of LEAP-JET code for sodium-water reaction analysis. Validation by sodium-water reaction tests (SWAT-1R)

    International Nuclear Information System (INIS)

    Seino, Hiroshi; Hamada, Hirotsugu

    2004-03-01

    The sodium-water reaction event in an FBR steam generator (SG) has influence on the safety, economical efficiency, etc. of the plant, so that the selection of design base leak (DBL) of the SG is considered as one of the important matters. The clarification of the sodium-water reaction phenomenon and the development of an analysis model are necessary to estimate the sodium-water reaction event with high accuracy and rationality in selecting the DBL. The reaction jet model is pointed out as a part of the necessary improvements to evaluate the overheating tube rupture of large SGs, since the behavior of overheating tube rupture is largely affected by the reaction jet conditions outside the tube. Therefore, LEAP-JET has been developed as an analysis code for the simulation of sodium-water reactions. This document shows the validation of the LEAP-JET code by the Sodium-Water Reaction Test (SWAT-1R). The following results have been obtained: (1) The reaction rate constant, K, is estimated at between 0.001≤K≤0.1 from the LEAP-JET analysis of the SWAT-1R data. (2) The analytical results on the high-temperature region and the behaviors of reaction consumption (Na, H 2 O) and products (H 2 , NaOH, Na 2 O) are considered to be physically reasonable. (3) The LEAP-JET analysis shows the tendency of overestimation in the maximum temperature and temperature distribution of the reaction jet. (4) In the LEAP-JET analysis, the numerical calculation becomes unstably, especially in the mesh containing quite small sodium mass. Therefore, it is necessary to modify the computational algorism to stabilize it and obtain the optimum value of K in sodium-water reactions. (author)

  5. Biomaterials for drug delivery patches.

    Science.gov (United States)

    Santos, Lúcia F; Correia, Ilídio J; Silva, A Sofia; Mano, João F

    2018-06-15

    The limited efficiency of conventional drugs has been instigated the development of new and more effective drug delivery systems (DDS). Transdermal DDS, are associated with numerous advantages such its painless application and less frequent replacement and greater flexibility of dosing, features that triggered the research and development of such devices. Such systems have been produced using either biopolymer; or synthetic polymers. Although the first ones are safer, biocompatible and present a controlled degradation by human enzymes or water, the second ones are the most currently available in the market due to their greater mechanical resistance and flexibility, and non-degradation over time. This review highlights the most recent advances (mainly in the last five years) of patches aimed for transdermal drug delivery, focusing on the different materials (natural, synthetic and blends) and latest designs for the development of such devices, emphasizing also their combination with drug carriers that enable enhanced drug solubility and a more controlled release of the drug over the time. The benefits and limitations of different patches formulations are considered with reference to their appliance to transdermal drug delivery. Furthermore, a record of the currently available patches on the market is given, featuring their most relevant characteristics. Finally, a list of most recent/ongoing clinical trials regarding the use of patches for skin disorders is detailed and critical insights on the current state of patches for transdermal drug delivery are also provided. Copyright © 2018. Published by Elsevier B.V.

  6. Microstrip Patch Sensor for Salinity Determination.

    Science.gov (United States)

    Lee, Kibae; Hassan, Arshad; Lee, Chong Hyun; Bae, Jinho

    2017-12-18

    In this paper, a compact microstrip feed inset patch sensor is proposed for measuring the salinities in seawater. The working principle of the proposed sensor depends on the fact that different salinities in liquid have different relative permittivities and cause different resonance frequencies. The proposed sensor can obtain better sensitivity to salinity changes than common sensors using conductivity change, since the relative permittivity change to salinity is 2.5 times more sensitive than the conductivity change. The patch and ground plane of the proposed sensor are fabricated by conductive copper spray coating on the masks made by 3D printer. The fabricated patch and the ground plane are bonded to a commercial silicon substrate and then attached to 5 mm-high chamber made by 3D printer so that it contains only 1 mL seawater. For easy fabrication and testing, the maximum resonance frequency was selected under 3 GHz and to cover salinities in real seawater, it was assumed that the salinity changes from 20 to 35 ppt. The sensor was designed by the finite element method-based ANSYS high-frequency structure simulator (HFSS), and it can detect the salinity with 0.01 ppt resolution. The designed sensor has a resonance frequency separation of 37.9 kHz and reflection coefficients under -20 dB at the resonant frequencies. The fabricated sensor showed better performance with average frequency separation of 48 kHz and maximum reflection coefficient of -35 dB. By comparing with the existing sensors, the proposed compact and low-cost sensor showed a better detection capability. Therefore, the proposed patch sensor can be utilized in radio frequency (RF) tunable sensors for salinity determination.

  7. Microstrip Patch Sensor for Salinity Determination

    Directory of Open Access Journals (Sweden)

    Kibae Lee

    2017-12-01

    Full Text Available In this paper, a compact microstrip feed inset patch sensor is proposed for measuring the salinities in seawater. The working principle of the proposed sensor depends on the fact that different salinities in liquid have different relative permittivities and cause different resonance frequencies. The proposed sensor can obtain better sensitivity to salinity changes than common sensors using conductivity change, since the relative permittivity change to salinity is 2.5 times more sensitive than the conductivity change. The patch and ground plane of the proposed sensor are fabricated by conductive copper spray coating on the masks made by 3D printer. The fabricated patch and the ground plane are bonded to a commercial silicon substrate and then attached to 5 mm-high chamber made by 3D printer so that it contains only 1 mL seawater. For easy fabrication and testing, the maximum resonance frequency was selected under 3 GHz and to cover salinities in real seawater, it was assumed that the salinity changes from 20 to 35 ppt. The sensor was designed by the finite element method-based ANSYS high-frequency structure simulator (HFSS, and it can detect the salinity with 0.01 ppt resolution. The designed sensor has a resonance frequency separation of 37.9 kHz and reflection coefficients under −20 dB at the resonant frequencies. The fabricated sensor showed better performance with average frequency separation of 48 kHz and maximum reflection coefficient of −35 dB. By comparing with the existing sensors, the proposed compact and low-cost sensor showed a better detection capability. Therefore, the proposed patch sensor can be utilized in radio frequency (RF tunable sensors for salinity determination.

  8. Tolerability, usability and acceptability of dissolving microneedle patch administration in human subjects.

    Science.gov (United States)

    Arya, Jaya; Henry, Sebastien; Kalluri, Haripriya; McAllister, Devin V; Pewin, Winston P; Prausnitz, Mark R

    2017-06-01

    To support translation of microneedle patches from pre-clinical development into clinical trials, this study examined the effect of microneedle patch application on local skin reactions, reliability of use and acceptability to patients. Placebo patches containing dissolving microneedles were administered to fifteen human participants. Microneedle patches were well tolerated in the skin with no pain or swelling and only mild erythema localized to the site of patch administration that resolved fully within seven days. Microneedle patches could be administered by hand without the need of an applicator and delivery efficiencies were similar for investigator-administration and self-administration. Microneedle patch administration was not considered painful and the large majority of subjects were somewhat or fully confident that they self-administered patches correctly. Microneedle patches were overwhelmingly preferred over conventional needle and syringe injection. Altogether, these results demonstrate that dissolving microneedle patches were well tolerated, easily usable and strongly accepted by human subjects, which will facilitate further clinical translation of this technology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Testing with fine fragrances in eczema patients

    DEFF Research Database (Denmark)

    Johansen, J D; Frosch, Peter J; Rastogi, Suresh Chandra

    2001-01-01

    The frequencies of contact allergic reactions to 2 fine fragrances were studied by patch testing. Further, a comparison was made of test results before and after evaporation of the solvent. A total of 480 consecutive eczema patients were included, 100 in the Dortmund clinic and 380 in the Gentoft...

  10. Analysis of acoustic data from UK sodium/water reaction test facilities

    International Nuclear Information System (INIS)

    Rowley, R.; Mcknight, J.A.; Airey, J.

    1990-01-01

    This paper describes acoustic measurements made during a number of sodium/water reaction experiments in the UK. The tests have included water and steam injections through both realistic (fatigue crack) defects and machined orifices and have covered a range of experimental conditions including those appropriate to the inlet and outlet regions of the EFR steam generators. Injection rates were typically in the range 0.1 to 30 g/s. Where possible, gas injections were also included in the test programme for comparison, since it is anticipated that a practical SGU acoustic leak detection system would include a facility for gas injections to allow system calibration, and to confirm transmission properties within the SGU. The test sections were instrumented with accelerometers on waveguides and in some cases included an under-sodium microphone situated about 300mm above the reaction zone. Tape recordings were made during the tests and used for detailed analysis off-line, although an audible output from one of the acoustic channels was used to monitor the progress of the injections and provide information for the rig operators. A comparison of the signal amplitudes measured during the experiments with typical reactor background noise was made and an estimate of the detection sensitivity of an acoustic monitoring system was deduced. 3 refs, 5 figs, 1 tab

  11. *NEW* CRITICAL Windows Security patches

    CERN Multimedia

    2003-01-01

    On 3 October and 10 September 2003, Microsoft issued new CRITICAL security patches MS03-040 and MS03-039. They must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security holes and patches are at: MS03-039: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp MS03-040: http://cern.ch/it-div/news/hotfix-MS03-040.asp http://www.microsoft.com/technet/security/bulletin/MS03-040.asp

  12. In vitro testing of defense reactions in zygotic and somatic embryos of Abies numidica

    Directory of Open Access Journals (Sweden)

    Jiří Hřib

    2011-01-01

    Full Text Available Defense of desiccated cotyledonary somatic embryos and mature zygotic embryos of Abies numidica was tested in vitro by dual cultures with tester, fungus Phaeolus schweinitzii. Both types of embryos expressed defense reactions manifested by inhibited growth of fungal tester towards the embryos. Mycelial growth was described by logistic sigmoid growth model with a single asymptote. Mutual comparisons of mycelial growth in presence of zygotic and somatic embryos showed significant differences in parameters of mycelium growth curves towards the embryos. Larger defense reactions were observed in zygotic embryos relative to somatic embryos and unlimited control cultivations without embryo. The possible role of auxin in the defense response of plant embryos is discussed.

  13. On null tests of time-reversal invariance in scattering and reactions

    International Nuclear Information System (INIS)

    Conzett, H.E.

    1993-01-01

    There have been suggestions in the literature, both recently and in the more distant past, that, in the lowest-order Born approximation, time-reversal (T)-odd experimental observables in certain reactions are required by T-symmetry to vanish. These observables are the final-state spin-correlation coefficient C xy in the reaction e + e - → τ + τ - and the target analysing power A oy in the inclusive process ep → eX with a polarized proton target. These assertions are in direct conflict with a theorem that states that there can be no null-test of T-symmetry in such processes; that is, T-symmetry does not require any single observable to vanish. This talk addresses the resolution of that conflict

  14. Neutron measurements from beam-target reactions at the ELISE neutral beam test facility

    International Nuclear Information System (INIS)

    Xufei, X.; Fan, T.; Nocente, M.; Gorini, G.; Bonomo, F.; Franzen, P.; Fröschle, M.; Grosso, G.; Tardocchi, M.; Grünauer, F.; Pasqualotto, R.

    2014-01-01

    Measurements of 2.5 MeV neutron emission from beam-target reactions performed at the ELISE neutral beam test facility are presented in this paper. The measurements are used to study the penetration of a deuterium beam in a copper dump, based on the observation of the time evolution of the neutron counting rate from beam-target reactions with a liquid scintillation detector. A calculation based on a local mixing model of deuterium deposition in the target up to a concentration of 20% at saturation is used to evaluate the expected neutron yield for comparison with data. The results are of relevance to understand neutron emission associated to beam penetration in a solid target, with applications to diagnostic systems for the SPIDER and MITICA Neutral Beam Injection prototypes

  15. Summary of Altitude Pulse Testing of a 100-lbf L02/LCH4 Reaction Control Engine

    Science.gov (United States)

    Marshall, William M.; Kleinhenz, Julie E.

    2011-01-01

    Recently, liquid oxygen-liquid methane (LO2/LCH4) has been considered as a potential "green" propellant alternative for future exploration missions. The Propulsion and Cryogenic Advanced Development (PCAD) project has been tasked by NASA to develop this propulsion combination to enable safe and cost effective exploration missions. To date, limited experience with such combinations exist, and as a result a comprehensive test program is critical to demonstrating the viability of implementing such a system. The NASA Glenn Research Center has conducted a test program of a 100-lbf (445-N) reaction control engine (RCE) at the center s Altitude Combustion Stand (ACS), focusing on altitude testing over a wide variety of operational conditions. The ACS facility includes a unique propellant conditioning feed system (PCFS) which allows precise control of propellant inlet conditions to the engine. Engine performance as a result of these inlet conditions was examined extensively during the test program. This paper is a companion to the previous specific impulse testing paper, and discusses the pulsed mode operation portion of testing, with a focus on minimum impulse bit (I-bit) and repeatable pulse performance. The engine successfully demonstrated target minimum impulse bit performance at all conditions, as well as successful demonstration of repeatable pulse widths. Some anomalous conditions experienced during testing are also discussed, including a double pulse phenomenon which was not noted in previous test programs for this engine.

  16. Evaluating the fall risk among elderly population by choice step reaction test

    Directory of Open Access Journals (Sweden)

    Wang D

    2016-08-01

    Full Text Available Donghai Wang,1 Jian Zhang,1 Yuliang Sun,2 Wenfei Zhu,2 Shiliu Tian,1 Yu Liu1 1Key Laboratory of Exercise and Health Sciences of the Ministry of Education, Shanghai University of Sport, Shanghai, People’s Republic of China; 2School of Physical Education, Shaanxi Normal University, Xian, People’s Republic of China Abstract: Falls during daily activities are often associated with injuries and physical disabilities, thereby affecting quality of life among elder adults. Balance control, which is crucial in avoiding falls, is composed of two elements: muscle strength and central nervous system (CNS control. A number of studies have reported that reduced muscle strength raises the risk of falling. However, to date there has been only limited research focused on the relationship between fall risk and the CNS. This study aimed to investigate the relationship between CNS and risk of falling among the elderly. A total of 140 elderly people (92 females and 48 males were divided into faller and nonfaller groups based on questionnaire responses concerning falls in their daily life. Participants undertook a choice step reaction test in which they were required to respond to random visual stimuli using foot movements as fast as possible in the left or right directions. Response time was quantified as premotor time (PMT and motor time (MT. In addition, the participants’ electromyography data were recorded during the choice step reaction test. A maximal isokinetic torque test was also performed. PMT was greater in the fallers than in the nonfallers group. There was a significant difference between fall status and direction on PMT. PMT of the left limb in nonfallers was faster than the right, but in fallers there was no difference between left and right limbs. A similar phenomenon was also observed for MT. There were significant differences between fallers and nonfallers in maximum isokinetic torque at knee and ankle joints. The correct rate of PMT was

  17. High dose brain CT with ioxaglate and diatrizoate adverse reactions and effects on urine protein tests

    International Nuclear Information System (INIS)

    Raininko, R.; Laivola, J.; Irjala, K.; Turku Univ. Central Hospital

    1988-01-01

    Sodium meglumine ioxaglate (320 or 306 mg I/ml) and meglumine diatrizoate (306 mg I/ml) in an intravenous dose of 2 ml/kg were compared in a randomized double-blind test on the brain CT of 209 patients. Side effects were noted in 56% of the ioxaglate group and 90% of the diatrizoate group. Diatrizoate caused a sensation of heat significantly more often and more intensely, but the frequencies of other side effects did not differ significantly. No severe reactions occurred. The quality of the CT scans was equal. Neither ioxaglate nor diatrizoate impaired renal function. False-positive strip tests and falsely elevated protein values measured by the biuretic method were found in particular in the ioxaglate group. The results of urine protein measurements and strip tests are misleading on the day of the examination with both ioxaglate and diatrizoate. (orig.)

  18. Departure mechanisms for host search on high-density patches by the Meteorus pulchricornis.

    Science.gov (United States)

    Sheng, Sheng; Feng, Sufang; Meng, Ling; Li, Baoping

    2014-01-01

    Less attention has been paid to the parasitoid-host system in which the host occurs in considerably high density with a hierarchical patch structure in studies on time allocation strategies of parasitoids. This study used the parasitoid Meteorus pulchricornis (Wesmael) (Hymenoptera: Braconidae) and the Oriental leafworm, Spodoptera litura (Fabricius) (Lepidoptera: Noctuidae) as the parasitoids-host model system to investigate patch-leaving mechanisms as affected by the high-host density, hierarchical patch structure, and foraging behaviors on both former and current patches. The results showed that three out of eight covariates tested had significant effects on the patch-leaving tendency, including the host density, ovipositor insertion, and host rejection on the current patch. The parasitoid paid more visits to the patch with high-density hosts. While the patch with higher host densities decreased the leaving tendency, the spatial distribution of hosts examined had no effect on the leaving tendency. Both oviposition and host rejection decreased the patch-leaving tendency. The variables associated with the former patch, such as the host density and number of ovipositor insertions, however, did not have an effect on the leaving tendency. Our study suggested that M. pulchricornis females may use an incremental mechanism to exploit high-density patches to the fullest. © The Author 2014. Published by Oxford University Press on behalf of the Entomological Society of America.

  19. ANAM4 TBI Reaction Time-Based Tests have Prognostic Utility for Acute Concussion

    Science.gov (United States)

    2013-07-01

    7:767. 2013 ANAM4 TBI Reaction Time-Based Tests Have Prognostic Utility for Acute Concussion LT Jacob N. Norris, MSC USN*; LCDR Waiter Carr, MSC USN...CDR Thomas Herzig, MSC USNf; CDR D. Waiter Labrie, MSC USNf; CDR Richard Sams, MC USN§ ABSTRACT The Concussion Restoration Care Center has used the...Work Unit No. N24LB. REFERENCES 1. Department of Defense: DoD Poiicy Guidance for Management of Mild Traumatic Brain Injury/Concussion in the Deployed

  20. Stability test and analysis of the Space Shuttle Primary Reaction Control Subsystem thruster

    Science.gov (United States)

    Applewhite, John; Hurlbert, Eric; Krohn, Douglas; Arndt, Scott; Clark, Robert

    1992-01-01

    The results are reported of a test program conducted on the Space Shuttle Primary Reaction Control Subsystem thruster in order to investigate the effects of trapped helium bubbles and saturated propellants on stability, determine if thruster-to-thruster stability variations are significant, and determine stability under STS-representative conditions. It is concluded that the thruster design is highly reliable in flight and that burn-through has not occurred. Significantly unstable thrusters are screened out, and wire wrap is found to protect against chamber burn-throughs and to provide a fail-safe thruster for this situation.

  1. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Nickel

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reaction 58Ni(n,p)58Co. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 2.1 MeV and for irradiation times up to about 200 days in the absence of high thermal neutron fluence rates (for longer irradiations, see Practice E 261). 1.3 With suitable techniques fission-neutron fluence rates densities above 107 cm−2·s−1 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note—The burnup corrections were com...

  2. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Iron

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    DESIG: E 263 09 ^TITLE: Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Iron ^SIGNUSE: Refer to Guide E 844 for guidance on the selection, irradiation, and quality control of neutron dosimeters. Refer to Practice E 261 for a general discussion of the determination of fast-neutron fluence rate with threshold detectors. Pure iron in the form of foil or wire is readily available and easily handled. Fig. 1 shows a plot of cross section as a function of neutron energy for the fast-neutron reaction 54Fe(n,p)54Mn (1). This figure is for illustrative purposes only to indicate the range of response of the 54Fe(n,p)54Mn reaction. Refer to Guide E 1018 for descriptions of recommended tabulated dosimetry cross sections. 54Mn has a half-life of 312.13 days (3) (2) and emits a gamma ray with an energy of 834.845 keV (5). (2) Interfering activities generated by neutron activation arising from thermal or fast neutron interactions are 2.57878 (46)-h 56Mn, 44.95-d (8) 59Fe, and 5.27...

  3. Standard Test Method for Measuring Reaction Rates by Radioactivation of Uranium-238

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by assaying a fission product (F.P.) from the fission reaction 238U(n,f)F.P. 1.2 The reaction is useful for measuring neutrons with energies from approximately 1.5 to 7 MeV and for irradiation times up to 30 to 40 years. 1.3 Equivalent fission neutron fluence rates as defined in Practice E 261 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other unites of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Standard Test Method for Measuring Reaction Rates by Radioactivation of Neptunium-237

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by assaying a fission product (F.P.) from the fission reaction 237Np(n,f)F.P. 1.2 The reaction is useful for measuring neutrons with energies from approximately 0.7 to 6 MeV and for irradiation times up to 30 to 40 years. 1.3 Equivalent fission neutron fluence rates as defined in Practice E 261 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Rotigotine transdermal patch for the treatment of Parkinson's Disease.

    Science.gov (United States)

    Perez-Lloret, Santiago; Rey, María Verónica; Ratti, Pietro Lucca; Rascol, Olivier

    2013-02-01

    Rotigotine, a non-ergot dopamine agonist, has been developed as a novel transdermal formulation. The rotigotine transdermal patch has received EMEA marketing authorization for the treatment of adult patients with early or advanced Parkinson's disease (PD) or with moderate to severe restless legs syndrome (RLS). FDA originally granted a marketing authorization for early PD, which was later suspended, and is now studying the authorization for RLS. The aim of this review is to review the pharmacokinetics, pharmacodynamics as well as the clinical efficacy and tolerability of the rotigotine transdermal patch in PD. Source material was identified using a PubMed search for the term 'rotigotine' and PD. Articles published up to January 2011 or abstract submitted to most relevant international neurology congresses were reviewed. The rotigotine transdermal patch is efficacious for the treatment of PD. Tolerability profile appears to be well within the range of that observed with other non-ergot dopamine agonists in PD. Application-site reactions were the most frequent adverse event, and they were considered mild to moderate in the majority of cases. The rotigotine transdermal patch offers a safe and efficacious alternative for the treatment of PD. Further studies should focus on the possibility that continuous dopamine stimulation by means of the transdermal patch has any influence on levodopa-related motor complications. © 2012 The Authors Fundamental and Clinical Pharmacology © 2012 Société Française de Pharmacologie et de Thérapeutique.

  6. Patch test results of the European baseline series among patients with occupational contact dermatitis across Europe - analyses of the European Surveillance System on Contact Allergy network, 2002-2010.

    Science.gov (United States)

    Pesonen, Maria; Jolanki, Riitta; Larese Filon, Francesca; Wilkinson, Mark; Kręcisz, Beata; Kieć-Świerczyńska, Marta; Bauer, Andrea; Mahler, Vera; John, Swen M; Schnuch, Axel; Uter, Wolfgang

    2015-03-01

    Occupational contact dermatitis is one of the most common occupational diseases in Europe. In order to develop effective preventive measures, detailed and up-to-date data on the incidence, main causes and professions at risk of occupational contact dermatitis are needed. To describe the pattern of patch test reactivity to allergens in the European baseline series of patients with occupational contact dermatitis in different occupations. We analysed data collected by the European Surveillance System on Contact Allergy (ESSCA) network from 2002 to 2010, from 11 European countries. Allergens in the European baseline series associated with an at least doubled risk of occupational contact dermatitis include: thiuram rubber chemical accelerators, epoxy resin, and the antimicrobials methylchloroisothiazolinone/methylisothiazolinone, methyldibromo glutaronitrile, and formaldehyde. The highest risk of occupational contact dermatitis was found in occupations classified as 'other personal services workers', which includes hairdressers, nursing and other healthcare professionals, precision workers in metal and related materials, and blacksmiths, tool-makers and related trades workers. In the planning and implementation of measures aimed at preventing occupational contact dermatitis, the focus should be on the identified high-risk occupational groups and the most common occupational allergies. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Utility of opium seed extract tests in preventing hypersensitivity reactions during surgery.

    Science.gov (United States)

    Armentia, A; Pineda, F; Palacios, R; Martín-Gil, F-J; Miguel, A S; Arenal, J J; Tejedor, J; Tef, B M

    2014-01-01

    Anaphylaxis during anaesthesia is fatal in 3-9% of patients and analgesics, including opioids, and is the second most common medicament-related cause, although the prevalence is underestimated. We recently found that patients may generate IgE antibodies to opium seeds. To determine the diagnostic accuracy of specific antibodies to morphine, codeine, rocuronium and oil body and aqueous fractions of Papaver somniferum seeds in the diagnosis and prevention of allergy to opioids. Patients with hypersensitivity reactions during surgery, and severe clinical allergy (pollen, tobacco), and illicit heroin users were selected. The sensitivity, specificity and predictive values of in vivo and in vitro diagnostic techniques including oil body and aqueous fractions of P. somniferum seeds were measured. We studied 203 patients, with mean age 35.1±17.1 and 200 healthy controls. Patients sensitised to heroin or with hypersensitivity reactions during surgery responded to P. somniferum seed tests. Of patients not known to be sensitised to opioids, the highest positivity was in patients sensitised to tobacco (pOpium seed skin tests and IgE, especially the oil body fraction, were more sensitive (64.2%) and specific (98.4%) than morphine, codeine and rocuronium tests for opioid sensitivity. Pollen allergy was not a risk factor for sensitisation to morphine. Sensitivity to opioids and intraoperative anaphylaxis can be diagnosed by routine tests. IgE and skin tests for the oil body fraction of P. somniferum had the highest sensitivity for sensitisation to opioids. Copyright © 2012 SEICAP. Published by Elsevier Espana. All rights reserved.

  8. Severe allergic hair dye reactions in 8 children

    DEFF Research Database (Denmark)

    Sosted, Heidi; Johansen, Jeanne Duus; Andersen, Klaus Ejner

    2006-01-01

    Serious adverse skin reactions to permanent hair dyes and temporary black tattoos have been reported. As temporary tattoos have become fashionable among adolescents, the risk profile for p-phenylenediamine (PPD) sensitization of the population has changed simultaneously with an increasing use...... of hair dyes in this age group. This investigation reports PPD sensitization in children with regard to cause of sensitization, clinical presentation and consequences. Clinical history and patch test results for consecutive children below 16 years of age with suspected hair dye allergic reactions...... and positive patch tests to PPD were collected over 2 years in 2 Danish dermatology clinics. 8 children aged 12-15 years were collected, and they all reacted to several hair dye ingredients. 5 of the patients were hospitalized, 1 in the intensive care unit. 6 of the patients gave a history of prior reaction...

  9. Microneedle Patches as Drug and Vaccine Delivery Platform.

    Science.gov (United States)

    Li, Junwei; Zeng, Mingtao; Shan, Hu; Tong, Chunyi

    2017-01-01

    Transcutaneous delivery is the ideal method for delivering therapeutic reagents or vaccines into skin. With their promise of self-administration, cost-effective and high efficiency, microneedle patches have been studied intensively as therapeutic and vaccination delivery platform that replaces injection by syringe. This review aims to summarize the recent advancements of microneedle patches in application for drugs and vaccine delivery. We reviewed the most of recently published papers on microneedle patches, summarized their evolution, classification, state-of the-art capabilities and discussed promising application in drugs and vaccine delivery. With the rapid development of nanotechnology, microneedle patches have been improved by switching from undissolving to dissolving microneedles, and their safety has also improved dramatically. As a drug delivery tool, microneedle patches can deliver bioactive molecular of different physical size. Additionally, microneedle patches can be coated or encapsulate with DNA vaccine, subunit antigen, inactivated or live virus vaccine. Combining clinical results with the results of patient interview, microneedle patches are found to be feasible and are predicated to soon be acceptable for the medical service. In this review, we summarized the evolution, current and future application of microneedle patches as delivery vehicle for drugs and vaccines. Compared with traditional delivery tools, microneedle patches have many advantages, such as providing pain-free, non-invasive, convenient route for reagent administration and delivery, with no cold chain required for storage and transportation as well as decreasing sharp medical waste, needle-caused injury and transmission of blood-borne infectious disease in rural area. However, even though there are dramatic progress in preclinical investigation of microneedle patches, further testing will be required for clinical application. Further research should be implemented in multiple fields

  10. Comparison of measured and calculated reaction rate distributions in an scwr-like test lattice

    Energy Technology Data Exchange (ETDEWEB)

    Raetz, Dominik, E-mail: dominik.raetz@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Jordan, Kelly A., E-mail: kelly.jordan@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Murphy, Michael F., E-mail: mike.murphy@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Perret, Gregory, E-mail: gregory.perret@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Chawla, Rakesh, E-mail: rakesh.chawla@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Ecole Polytechnique Federale de Lausanne (EPFL), CH-1015 Lausanne, EPFL (Switzerland)

    2011-04-15

    High resolution gamma-ray spectroscopy measurements were performed on 61 rods of an SCWR-like fuel lattice, after irradiation in the central test zone of the PROTEUS zero-power research reactor at the Paul Scherrer Institute in Switzerland. The derived reaction rates are the capture rate in {sup 238}U (C{sub 8}) and the total fission rate (F{sub tot}), and also the reaction rate ratio C{sub 8}/F{sub tot}. Each of these has been mapped rod-wise on the lattice and compared to calculated results from whole-reactor Monte Carlo simulations with MCNPX. Ratios of calculated to experimental values (C/E's) have been assessed for the C{sub 8}, F{sub tot} and C{sub 8}/F{sub tot} distributions across the lattice. These C/E's show excellent agreement between the calculations and the measurements. For the {sup 238}U capture rate distribution, the 1{sigma} level in the comparisons corresponds to an uncertainty of {+-}0.8%, while for the total fission rate the corresponding value is {+-}0.4%. The uncertainty for C{sub 8}/F{sub tot}, assessed as a reaction rate ratio characterizing each individual rod position in the test lattice, is significantly higher at {+-}2.2%. To determine the reproducibility of these results, the measurements were performed twice, once in 2006 and again in 2009. The agreement between these two measurement sets is within the respective statistical uncertainties.

  11. Patch layout generation by detecting feature networks

    KAUST Repository

    Cao, Yuanhao; Yan, Dongming; Wonka, Peter

    2015-01-01

    The patch layout of 3D surfaces reveals the high-level geometric and topological structures. In this paper, we study the patch layout computation by detecting and enclosing feature loops on surfaces. We present a hybrid framework which combines

  12. Evaluation of concrete pavement patching techniques.

    Science.gov (United States)

    1989-01-01

    This final report presents the results of a study undertaken to improve in concrete pavement patching techniques. Activities included an evaluation of the suitability of the impact hammer and maturity calculations for determining when a patch is read...

  13. Improved image registration by sparse patch-based deformation estimation.

    Science.gov (United States)

    Kim, Minjeong; Wu, Guorong; Wang, Qian; Lee, Seong-Whan; Shen, Dinggang

    2015-01-15

    Despite intensive efforts for decades, deformable image registration is still a challenging problem due to the potential large anatomical differences across individual images, which limits the registration performance. Fortunately, this issue could be alleviated if a good initial deformation can be provided for the two images under registration, which are often termed as the moving subject and the fixed template, respectively. In this work, we present a novel patch-based initial deformation prediction framework for improving the performance of existing registration algorithms. Our main idea is to estimate the initial deformation between subject and template in a patch-wise fashion by using the sparse representation technique. We argue that two image patches should follow the same deformation toward the template image if their patch-wise appearance patterns are similar. To this end, our framework consists of two stages, i.e., the training stage and the application stage. In the training stage, we register all training images to the pre-selected template, such that the deformation of each training image with respect to the template is known. In the application stage, we apply the following four steps to efficiently calculate the initial deformation field for the new test subject: (1) We pick a small number of key points in the distinctive regions of the test subject; (2) for each key point, we extract a local patch and form a coupled appearance-deformation dictionary from training images where each dictionary atom consists of the image intensity patch as well as their respective local deformations; (3) a small set of training image patches in the coupled dictionary are selected to represent the image patch of each subject key point by sparse representation. Then, we can predict the initial deformation for each subject key point by propagating the pre-estimated deformations on the selected training patches with the same sparse representation coefficients; and (4) we

  14. 389 Allergic Reactions to Local Anesthetics: Detection by Skin Tests and Subcutaneous Provocation. Analysis of 160 Cases

    Science.gov (United States)

    Arcanjo, Luiz; Gonçalves Tavares, Tania Maria; Delcourt, Nathalia; Baroni, Juliana; Rios, João; Rios, José Luiz

    2012-01-01

    Background Adverse reactions to local anesthetics (LA) are frequent and often referred to as allergic. Although immune-mediated reactions are rare, it should be investigated for suspected cases. The objective of this study was to determine the frequency of positive skin test to these drugs in patients with a suspected history of allergic reactions and describe the main socio-demographic characteristics of these individuals. Methods Retrospective study of medical records of patients attended at Policlínica Geral do Rio de Janeiro Allergic Clinic, between 2008 and 2011. The parameters evaluated were the test indication and the patient ages and gender. The drug tested was that the patient had a history of suspicion. Patients underwent skin prick and intradermal tests and subcutaneous provocation. Descriptive statistical analysis of the data was performed. Results It was performed 160 tests (125 female). Three of this total was excluded due to inconclusive results. In women, the highest proportion of tests was in the age group from 41 to 60 years (43%), while in males the higher concentration was at a youngest age group: 21 to 40 years (41%). The most common indication (103 cases, 65%) for the tests was a previous suspected anaphylactic reaction by LA. Seven of 157 tests had a positive result (4.4%), 6 of them occurred in women (4.8%). Only one test resulted in a type of anaphylactic reaction response (0.67%). All patients who presented positive response to the test had a history of per-anesthetic reaction that suggested an immune-mediated mechanism. Conclusions In patients with a history of previous reaction to local anesthetics, the skin tests with these drugs have a key role in the prevention of anaphylaxis, and on guidance for adequate anesthetic procedures.

  15. Patch testing with constituents of Compositae mixes

    DEFF Research Database (Denmark)

    Paulsen, Evy; Andersen, Klaus Ejner

    2012-01-01

    Background. The development of mixes containing Compositae plant extracts has improved the diagnosis of Compositae contact allergy, but none of them has fulfilled the criteria for an ideal European plant mix. Objective. To evaluate which constituents of two commercial Compositae mixes were most u...

  16. Motion perception and driving: predicting performance through testing and shortening braking reaction times through training.

    Science.gov (United States)

    Wilkins, Luke; Gray, Rob; Gaska, James; Winterbottom, Marc

    2013-12-30

    A driving simulator was used to examine the relationship between motion perception and driving performance. Although motion perception test scores have been shown to be related to driving safety, it is not clear which combination of tests are the best predictors and whether motion perception training can improve driving performance. In experiment 1, 60 younger drivers (22.4 ± 2.5 years) completed three motion perception tests (2-dimensional [2D] motion-defined letter [MDL] identification, 3D motion in depth sensitivity [MID], and dynamic visual acuity [DVA]) followed by two driving tests (emergency braking [EB] and hazard perception [HP]). In experiment 2, 20 drivers (21.6 ± 2.1 years) completed 6 weeks of motion perception training (using the MDL, MID, and DVA tests), while 20 control drivers (22.0 ± 2.7 years) completed an online driving safety course. The EB performance was measured before and after training. In experiment 1, MDL (r = 0.34) and MID (r = 0.46) significantly correlated with EB score. The change in DVA score as a function of target speed (i.e., "velocity susceptibility") was correlated most strongly with HP score (r = -0.61). In experiment 2, the motion perception training group had a significant decrease in brake reaction time on the EB test from pre- to posttreatment, while there was no significant change for the control group: t(38) = 2.24, P = 0.03. Tests of 3D motion perception are the best predictor of EB, while DVA velocity susceptibility is the best predictor of hazard perception. Motion perception training appears to result in faster braking responses.

  17. Streamlining of plant patches in streams

    DEFF Research Database (Denmark)

    Jensen, Kaj Sand; Pedersen, Morten Lauge

    2008-01-01

    . Sediment elevation within patches (avg. 4.1 cm) increased significantly with patch length, but did not differ between unstable sand or more stable coarse sediment for the same patch length. Shape of canopy and root area did not change significantly with sediment type. 4. Pressure drag on the canopy...

  18. Role of Histamine Release Test for the Evaluation of Patients with Immediate Hypersensitivity Reactions to Clavulanic Acid

    DEFF Research Database (Denmark)

    Pineda, F.; Ariza, A.; Mayorga, C.

    2015-01-01

    Immediate hypersensitivity reactions to clavulanic acid (CLV) seem to be on the increase. Diagnosis is mainly based on skin testing and the drug provocation test (DPT), procedures that are not risk free. The aim of this study was to evaluate whether the histamine release test (HRT) could help eva...

  19. A test on reactive force fields for the study of silica dimerization reactions

    Energy Technology Data Exchange (ETDEWEB)

    Moqadam, Mahmoud; Riccardi, Enrico; Trinh, Thuat T.; Åstrand, Per-Olof; Erp, Titus S. van, E-mail: titus.van.erp@ntnu.no [Department of Chemistry, Norwegian University of Science and Technology (NTNU), Høgskoleringen 5, Realfagbygget D3-117, 7491 Trondheim (Norway)

    2015-11-14

    We studied silica dimerization reactions in the gas and aqueous phase by density functional theory (DFT) and reactive force fields based on two parameterizations of ReaxFF. For each method (both ReaxFF force fields and DFT), we performed constrained geometry optimizations, which were subsequently evaluated in single point energy calculations using the other two methods. Standard fitting procedures typically compare the force field energies and geometries with those from quantum mechanical data after a geometry optimization. The initial configurations for the force field optimization are usually the minimum energy structures of the ab initio database. Hence, the ab initio method dictates which structures are being examined and force field parameters are being adjusted in order to minimize the differences with the ab initio data. As a result, this approach will not exclude the possibility that the force field predicts stable geometries or low transition states which are realistically very high in energy and, therefore, never considered by the ab initio method. Our analysis reveals the existence of such unphysical geometries even at unreactive conditions where the distance between the reactants is large. To test the effect of these discrepancies, we launched molecular dynamics simulations using DFT and ReaxFF and observed spurious reactions for both ReaxFF force fields. Our results suggest that the standard procedures for parameter fitting need to be improved by a mutual comparative method.

  20. Capacitance of circular patch resonator

    International Nuclear Information System (INIS)

    Miano, G.; Verolino, L.; Naples Univ.; Panariello, G.; Vaccaro, V.G.; Naples Univ.

    1995-11-01

    In this paper the capacitance of the circular microstrip patch resonator is computed. It is shown that the electrostatic problem can be formulated as a system of dual integral equations, and the most interesting techniques of solutions of these systems are reviewed. Some useful approximated formulas for the capacitance are derived and plots of the capacitance are finally given in a wide range of dielectric constants

  1. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study.

    Science.gov (United States)

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan; Dirksen, Asger; Elberling, Jesper

    2011-06-01

    Multiple chemical sensitivity (MCS) is characterised by adverse effects due to exposure to low levels of chemical substances. The aetiology is unknown, but chemical related respiratory symptoms have been found associated with positive patch test. The purpose of this study was to investigate the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened for chemical sensitivity with a standardised questionnaire dividing the participants into four severity groups of chemical sensitivity. Both allergic and non-allergic cutaneous reactions--defined as irritative, follicular, or doubtful allergic reactions--were analysed in relationship with severity of chemical sensitivity. Associations were controlled for the possible confounding effects of sex, age, asthma, eczema, atopic dermatitis, psychological and social factors, and smoking habits. In unadjusted analyses we found associations between allergic and non-allergic cutaneous reactions on patch testing and the two most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0.006). Our results suggest that individuals with self-reported chemical sensitivity show increased non-allergic cutaneous reactions based on day 2 readings of patch tests. Copyright © 2011 Elsevier GmbH. All rights reserved.

  2. Foraging decisions, patch use, and seasonality in egrets (Aves: ciconiiformes)

    Science.gov (United States)

    Erwin, R.M.

    1985-01-01

    Feeding snowy (Egretta thula) and great (Casmerodius albus) egrets were observed during 2 breeding seasons in coastal New Jersey and 2 brief winter periods in northeast Florida (USA). A number of tests based on assumptions of foraging models, predictions from foraging theory, and earlier empirical tests concerning time allocation and movement in foraging patches was made. Few of the expectations based on foraging theory and/or assumptions were supported by the empirical evidence. Snowy egrets fed with greater intensity and efficiency during the breeding season (when young were being fed) than during winter. They also showed some tendency to leave patches when their capture rate declined, and they spent more time foraging in patches when other birds were present nearby. Great egrets showed few of these tendencies, although they did leave patches when their intercapture intervals increased. Satiation differences had some influence on feeding rates in snowy egrets, but only at the end of feeding bouts. Some individuals of both species revisited areas in patches that had recently been exploited, and success rates were usually higher after the 2nd visit. Apparently, for predators of active prey, short-term changes in resource availability ('resource depression') may be more important than resource depletion, a common assumption in most optimal foraging theory models.

  3. Adobe Flash as a medium for online experimentation: a test of reaction time measurement capabilities.

    Science.gov (United States)

    Reimers, Stian; Stewart, Neil

    2007-08-01

    Adobe Flash can be used to run complex psychological experiments over the Web. We examined the reliability of using Flash to measure reaction times (RTs) using a simple binary-choice task implemented both in Flash and in a Linux-based system known to record RTs with millisecond accuracy. Twenty-four participants were tested in the laboratory using both implementations; they also completed the Flash version on computers of their own choice outside the lab. RTs from the trials run on Flash outside the lab were approximately 20 msec slower than those from trials run on Flash in the lab, which in turn were approximately 10 msec slower than RTs from the trials run on the Linux-based system (baseline condition). RT SDs were similar in all conditions, suggesting that although Flash may overestimate RTs slightly, it does not appear to add significant noise to the data recorded.

  4. International reactions after the resumption of nuclear tests: lot of noise for nothing?; Les reactions internationales a la reprise des essais nucleaires: beaucoup de bruit pour rien?

    Energy Technology Data Exchange (ETDEWEB)

    Montesquieu, E. de

    1996-07-01

    In 1995, the French President announced that France would perform an ultimate campaign of nuclear tests before a complete banishment as soon as spring 1996. The campaign effectively ended on time and six tests took place between September 5, 1995 and January 27, 1996. The disarmament process went on and the international negotiations in progress at that time were not affected by the French policy. However, this campaign has caused a strong emotion, if not in the entire World, at least in part of the planet and in particular in Western Europe. This report analyses the reactions from the different governments and from the public opinion and shows their impact on the French diplomacy. Content: Part 1 - general considerations: 1 - lot of noise for nothing?: the objectives of French diplomacy; the acts (a quasi lack of sanctions, a temporary degradation of our relations with a limited number of countries); the rhetoric (diplomatic regrets in first time, slip-ups in the second time, the public opinion weight); 2 - the lessons learnt: the opinion and the management of the foreign policy (the image of France, the communication fight); the geopolitical lessons (European Union: community solidarity and European defense; the South Pacific area); 3 - a case study: Japan: the time of uncertainties (domestic situation, external policy); the Japanese reactions after the tests resumption. Part 2 - synthesis of reactions after the resumption of nuclear tests by France: Pacific bordering countries (South Pacific, Latin America); Western Europe countries; non-European countries; Conclusions.

  5. Orion Exploration Flight Test Reaction Control System Jet Interaction Heating Environment from Flight Data

    Science.gov (United States)

    White, Molly E.; Hyatt, Andrew J.

    2016-01-01

    The Orion Multi-Purpose Crew Vehicle (MPCV) Reaction Control System (RCS) is critical to guide the vehicle along the desired trajectory during re-­-entry. However, this system has a significant impact on the convective heating environment to the spacecraft. Heating augmentation from the jet interaction (JI) drives thermal protection system (TPS) material selection and thickness requirements for the spacecraft. This paper describes the heating environment from the RCS on the afterbody of the Orion MPCV during Orion's first flight test, Exploration Flight Test 1 (EFT-1). These jet plumes interact with the wake of the crew capsule and cause an increase in the convective heating environment. Not only is there widespread influence from the jet banks, there may also be very localized effects. The firing history during EFT-1 will be summarized to assess which jet bank interaction was measured during flight. Heating augmentation factors derived from the reconstructed flight data will be presented. Furthermore, flight instrumentation across the afterbody provides the highest spatial resolution of the region of influence of the individual jet banks of any spacecraft yet flown. This distribution of heating augmentation across the afterbody will be derived from the flight data. Additionally, trends with possible correlating parameters will be investigated to assist future designs and ground testing programs. Finally, the challenges of measuring JI, applying this data to future flights and lessons learned will be discussed.

  6. Induction of the acrosome reaction test to in vitro estimate embryo production in Nelore cattle

    Directory of Open Access Journals (Sweden)

    M.Z. Costa

    2010-08-01

    Full Text Available The effectiveness of induction of the acrosome reaction (AR test as a parameter to in vitro estimate embryo production (IVP in Nelore breed and the AR pattern by the Trypan Blue/Giemsa (TB stain were evaluated. Frozen semen samples from ten Nelore bulls were submitted to AR induction and were also evaluated for cleavage and blastocyst rates. The treatments utilized for AR induction were: control (TALP medium, TH (TALP medium + 10μg heparin, TL (TALP medium + 100μg lysophosphatidylcholine and THL (TALP medium + 10μg heparin + 100μg lysophosphatidylcholine. Sperm acrosomal status and viability were evaluated by TB staining at 0 and after 4h incubation at 38°C. The results obtained for AR presented a significant difference (P<0.05 in the percentage of acrosome reacted live sperm after 4h of incubation in the treatments that received heparin. The cleavage and blastocyst rates were 60% and 38% respectively and a significant difference was observed among bulls (P<0.05. It was founded a satisfactory model to estimate the cleavage and blastocyst rates by AR induction test. Therefore, it can be concluded that the induction of the AR test is a valuable tool to predict the IVP in Nelore breed.

  7. Aspergillus Polymerase Chain Reaction: Systematic Review of Evidence for Clinical Use in Comparison With Antigen Testing

    Science.gov (United States)

    White, P. Lewis; Wingard, John R.; Bretagne, Stéphane; Löffler, Jürgen; Patterson, Thomas F.; Slavin, Monica A.; Barnes, Rosemary A.; Pappas, Peter G.; Donnelly, J. Peter

    2015-01-01

    Background. Aspergillus polymerase chain reaction (PCR) was excluded from the European Organisation for the Research and Treatment of Cancer/Mycoses Study Group (EORTC/MSG) definitions of invasive fungal disease because of limited standardization and validation. The definitions are being revised. Methods. A systematic literature review was performed to identify analytical and clinical information available on inclusion of galactomannan enzyme immunoassay (GM-EIA) (2002) and β-d-glucan (2008), providing a minimal threshold when considering PCR. Categorical parameters and statistical performance were compared. Results. When incorporated, GM-EIA and β-d-glucan sensitivities and specificities for diagnosing invasive aspergillosis were 81.6% and 91.6%, and 76.9% and 89.4%, respectively. Aspergillus PCR has similar sensitivity and specificity (76.8%–88.0% and 75.0%–94.5%, respectively) and comparable utility. Methodological recommendations and commercial PCR assays assist standardization. Although all tests have limitations, currently, PCR is the only test with independent quality control. Conclusions. We propose that there is sufficient evidence that is at least equivalent to that used to include GM-EIA and β-d-glucan testing, and that PCR is now mature enough for inclusion in the EORTC/MSG definitions. PMID:26113653

  8. Testing a potential alternative to traditional identification procedures: Reaction time-based concealed information test does not work for lineups with cooperative witnesses.

    Science.gov (United States)

    Sauerland, Melanie; Wolfs, Andrea C F; Crans, Samantha; Verschuere, Bruno

    2017-11-27

    Direct eyewitness identification is widely used, but prone to error. We tested the validity of indirect eyewitness identification decisions using the reaction time-based concealed information test (CIT) for assessing cooperative eyewitnesses' face memory as an alternative to traditional lineup procedures. In a series of five experiments, a total of 401 mock eyewitnesses watched one of 11 different stimulus events that depicted a breach of law. Eyewitness identifications in the CIT were derived from longer reaction times as compared to well-matched foil faces not encountered before. Across the five experiments, the weighted mean effect size d was 0.14 (95% CI 0.08-0.19). The reaction time-based CIT seems unsuited for testing cooperative eyewitnesses' memory for faces. The careful matching of the faces required for a fair lineup or the lack of intent to deceive may have hampered the diagnosticity of the reaction time-based CIT.

  9. A large-scale deforestation experiment: Effects of patch area and isolation on Amazon birds

    Science.gov (United States)

    Ferraz, G.; Nichols, J.D.; Hines, J.E.; Stouffer, P.C.; Bierregaard, R.O.; Lovejoy, T.E.

    2007-01-01

    As compared with extensive contiguous areas, small isolated habitat patches lack many species. Some species disappear after isolation; others are rarely found in any small patch, regardless of isolation. We used a 13-year data set of bird captures from a large landscape-manipulation experiment in a Brazilian Amazon forest to model the extinction-colonization dynamics of 55 species and tested basic predictions of island biogeography and metapopulation theory. From our models, we derived two metrics of species vulnerability to changes in isolation and patch area. We found a strong effect of area and a variable effect of isolation on the predicted patch occupancy by birds.

  10. Multiplex polymerase chain reaction test for the diagnosis of acute viral hepatitis A.

    Science.gov (United States)

    Heo, Nae-Yun; Lim, Young-Suk; An, Jihyun; Ko, Sun-Young; Oh, Heung-Bum

    2012-12-01

    The early diagnosis of acute hepatitis A (AHA) is hindered because serum IgM against hepatitis A virus (HAV) can yield false-negative results during the window period. This study evaluated the diagnostic accuracy of a polymerase chain reaction (PCR) kit for HAV RNA for the diagnosis of AHA. Samples were collected from 136 patients with acute severe hepatitis at their admission to Asan Medical Center between June 2010 and July 2010. Samples were analyzed for serum IgM anti-HAV using an immunoassay test and for qualitative HAV RNA using the Magicplex HepaTrio PCR test kit. The diagnostic accuracies of these methods were tested on the basis of clinical and laboratory diagnoses of AHA. The concordance rate and kappa value between IgM anti-HAV and HAV RNA PCR were 88.2% and 0.707, respectively. For the diagnosis of AHA, the sensitivity and specificity of IgM anti-HAV were 90.7% and 100%, respectively, when an "equivocal" result was regarded as positive; and 79.1% and 100%, respectively, when an "equivocal" result was regarded as negative. The sensitivity and specificity of HAV RNA PCR were 81.4% and 100%, respectively. All four patients with negative IgM anti-HAV and positive HAV RNA PCR results and all four patients with equivocal IgM anti-HAV RNA and positive HAV RNA PCR results were eventually diagnosed with AHA. The qualitative HAV RNA PCR test has an equivalent diagnostic accuracy for AHA compared to IgM anti-HAV and may be more sensitive during the window period.

  11. [The relevance of junctional rhythm during neurocardiogenic reaction provoked by tilt testing].

    Science.gov (United States)

    Zyśko, Dorota; Gajek, Jacek; Agrawal, Anil Kumar; Rudnicki, Jerzy

    2012-01-01

    During neurocardiogenic reaction provoked by tilt testing (TT), different arrhythmias such as sinus bradycardia, sinus arrest, atrioventricular block or junctional rhythm or beats (JR) may occur. The characteristics of the JR during neurocardiogenic reaction have not yet been systematically assessed. It is not known whether the presence of JR during neurocardiogenic reaction is related to clinical characteristics of syncopal patients or the outcome of TT. To assess whether clinical outcome of TT and clinical data are related to the presence of JR during TT. The study group consisted of 532 patients aged 43.3 ± 18.2 years with positive TT, divided into four groups on the basis of the presence of JR and/or a ventricular pause (VP) during neurocardiogenic reaction: group VP(-)/JR(+) - JR present and VP absent, group VP(+)/JR(+) - both JR and VP present, group VP(+)/JR(-) - JR absent and VP present, and group VP(-)/JR(-) - both JR and VP absent. The control group consisted of 53 patients with no history of syncope or presyncope, including 46 patients with negative TT and seven patients with false positive TT. Total loss of consciousness during TT occurred in group VP(-)/JR(+) less frequently than in groups VP(+)/JR(+) and VP(+)/JR(-), and more frequently than in group VP(-)/JR(-) (80% vs 96% vs 94% vs 62%; p 〈 0.05 for both comparisons). Group VP(-)/JR(+) was significantly younger than group VP(-)/JR(-) (37.3 ± 16.3 years vs 45.8 ± 18.9 years; p 〈 0.05) and had a lower number of syncopal events than group VP(+)/JR(+) and VP(+)/JR(-) (median [IQ]: 2.5 (1-6) vs 4 (2-12) and 4 (2-10), respectively; p 〈 0.05) and lower rate of traumatic injuries than group VP(+)/JR(+) and VP(+)/JR(-) (22% vs 45% and 39%, respectively; p 〈 0.05). Logistic regression analysis revealed that the presence of JR was associated with younger age, male gender, history of blood-instrumentation-injection phobia and higher number of syncopal spells in medical history. The ROC curve analysis

  12. Detecting Malaria Hotspots: A Comparison of Rapid Diagnostic Test, Microscopy, and Polymerase Chain Reaction.

    Science.gov (United States)

    Mogeni, Polycarp; Williams, Thomas N; Omedo, Irene; Kimani, Domtila; Ngoi, Joyce M; Mwacharo, Jedida; Morter, Richard; Nyundo, Christopher; Wambua, Juliana; Nyangweso, George; Kapulu, Melissa; Fegan, Gregory; Bejon, Philip

    2017-11-27

    Malaria control strategies need to respond to geographical hotspots of transmission. Detection of hotspots depends on the sensitivity of the diagnostic tool used. We conducted cross-sectional surveys in 3 sites within Kilifi County, Kenya, that had variable transmission intensities. Rapid diagnostic test (RDT), microscopy, and polymerase chain reaction (PCR) were used to detect asymptomatic parasitemia, and hotspots were detected using the spatial scan statistic. Eight thousand five hundred eighty-one study participants were surveyed in 3 sites. There were statistically significant malaria hotspots by RDT, microscopy, and PCR for all sites except by microscopy in 1 low transmission site. Pooled data analysis of hotspots by PCR overlapped with hotspots by microscopy at a moderate setting but not at 2 lower transmission settings. However, variations in degree of overlap were noted when data were analyzed by year. Hotspots by RDT were predictive of PCR/microscopy at the moderate setting, but not at the 2 low transmission settings. We observed long-term stability of hotspots by PCR and microscopy but not RDT. Malaria control programs may consider PCR testing to guide asymptomatic malaria hotspot detection once the prevalence of infection falls. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  13. THE REACTION TO FIRE TEST FOR FIRE RETARDANT AND FOR COMBUSTIBLE MATERIAL

    Directory of Open Access Journals (Sweden)

    Adelaida FANFAROVÁ

    2016-12-01

    Full Text Available Currently the natural materials become popular building material for houses, buildings and recreational property. The risk of fires in residential timber construction or eco houses cannot be completely ruled out, therefore there is a need for proper and correct implementing preventive measures and application of all available solutions, which may reduce the risk of fire as far as possible, to slow down the combustion process, to protect the life of people, animals and also the building itself until arrival members of the Fire and Rescue Services. Fireproofing of combustible materials is a specific area of fire protection. For scientific research as well as for real-life practice, not only their structural and physical properties, but also fire-technical characteristics are really important. The present researchers mostly focus on fire-retardant treatment of wood that is why the authors of this contribution focused on a different combustible material. This research article presents the experimental testing and examination of the reaction to fire test of the selected thermal insulation of hemp fiber that was impregnated by the selected fire retardant in laboratory conditions.

  14. Evaluation of multiplex polymerase chain reaction as an alternative to conventional antibiotic sensitivity test

    Directory of Open Access Journals (Sweden)

    K. Rathore

    2018-04-01

    Full Text Available Aim: This study was designed to evaluate the potential of the use of multiplex polymerase chain reaction (PCR as an alternative to conventional antibiotic sensitivity test. Materials and Methods: Isolates of Staphylococcus aureus (total = 36 from clinical cases presented to Teaching Veterinary Clinical Complex of College of Veterinary and Animal Sciences (CVAS, Navania, Udaipur, were characterized by morphological, cultural, and biochemical methods. Then, the isolates were further subjected to molecular characterization by PCR targeting S. aureus-specific sequence (107 bp. Phenotypic antibiotic sensitivity pattern was analyzed by Kirby Bauer disc diffusion method against 11 commonly used antibiotics in veterinary medicine in and around Udaipur region. The genotypic antibiotic sensitivity pattern was studied against methicillin, aminoglycosides, and tetracycline targeting the gene mecA, aacA-aphD, and tetK by multiplex PCR. Results: There was 100% correlation between the phenotype and genotype of aminoglycoside resistance, more than 90% correlation for methicillin resistance, and 58.3% in the case tetracycline resistance. Conclusion: As there is a good correlation between phenotype and genotype of antibiotic resistance, multiplex PCR can be used as an alternative to the conventional antibiotic susceptibility testing, as it can give a rapid and true prediction of antibiotic sensitivity pattern.

  15. Patched bimetallic surfaces are active catalysts for ammonia decomposition.

    Science.gov (United States)

    Guo, Wei; Vlachos, Dionisios G

    2015-10-07

    Ammonia decomposition is often used as an archetypical reaction for predicting new catalytic materials and understanding the very reason of why some reactions are sensitive on material's structure. Core-shell or surface-segregated bimetallic nanoparticles expose outstanding activity for many heterogeneously catalysed reactions but the reasons remain elusive owing to the difficulties in experimentally characterizing active sites. Here by performing multiscale simulations in ammonia decomposition on various nickel loadings on platinum (111), we show that the very high activity of core-shell structures requires patches of the guest metal to create and sustain dual active sites: nickel terraces catalyse N-H bond breaking and nickel edge sites drive atomic nitrogen association. The structure sensitivity on these active catalysts depends profoundly on reaction conditions due to kinetically competing relevant elementary reaction steps. We expose a remarkable difference in active sites between transient and steady-state studies and provide insights into optimal material design.

  16. Robust Tracking with Discriminative Ranking Middle-Level Patches

    Directory of Open Access Journals (Sweden)

    Hong Liu

    2014-04-01

    Full Text Available The appearance model has been shown to be essential for robust visual tracking since it is the basic criterion to locating targets in video sequences. Though existing tracking-by-detection algorithms have shown to be greatly promising, they still suffer from the drift problem, which is caused by updating appearance models. In this paper, we propose a new appearance model composed of ranking middle-level patches to capture more object distinctiveness than traditional tracking-by-detection models. Targets and backgrounds are represented by both low-level bottom-up features and high-level top-down patches, which can compensate each other. Bottom-up features are defined at the pixel level, and each feature gets its discrimination score through selective feature attention mechanism. In top-down feature extraction, rectangular patches are ranked according to their bottom-up discrimination scores, by which all of them are clustered into irregular patches, named ranking middle-level patches. In addition, at the stage of classifier training, the online random forests algorithm is specially refined to reduce drifting problems. Experiments on challenging public datasets and our test videos demonstrate that our approach can effectively prevent the tracker drifting problem and obtain competitive performance in visual tracking.

  17. Modelling of the spallation reaction: analysis and testing of nuclear models

    International Nuclear Information System (INIS)

    Toccoli, C.

    2000-01-01

    The spallation reaction is considered as a 2-step process. First a very quick stage (10 -22 , 10 -29 s) which corresponds to the individual interaction between the incident projectile and nucleons, this interaction is followed by a series of nucleon-nucleon collisions (intranuclear cascade) during which fast particles are emitted, the nucleus is left in a strongly excited level. Secondly a slower stage (10 -18 , 10 -19 s) during which the nucleus is expected to de-excite completely. This de-excitation is performed by evaporation of light particles (n, p, d, t, 3 He, 4 He) or/and fission or/and fragmentation. The HETC code has been designed to simulate spallation reactions, this simulation is based on the 2-steps process and on several models of intranuclear cascades (Bertini model, Cugnon model, Helder Duarte model), the evaporation model relies on the statistical theory of Weiskopf-Ewing. The purpose of this work is to evaluate the ability of the HETC code to predict experimental results. A methodology about the comparison of relevant experimental data with results of calculation is presented and a preliminary estimation of the systematic error of the HETC code is proposed. The main problem of cascade models originates in the difficulty of simulating inelastic nucleon-nucleon collisions, the emission of pions is over-estimated and corresponding differential spectra are badly reproduced. The inaccuracy of cascade models has a great impact to determine the excited level of the nucleus at the end of the first step and indirectly on the distribution of final residual nuclei. The test of the evaporation model has shown that the emission of high energy light particles is under-estimated. (A.C.)

  18. Optimizing polymerase chain reaction testing for the diagnosis of pertussis: current perspectives

    Directory of Open Access Journals (Sweden)

    Arbefeville S

    2015-09-01

    Full Text Available Sophie Arbefeville, Patricia Ferrieri Department of Laboratory Medicine and Pathology, University of Minnesota Medical School, Minneapolis, MN, USA Abstract: Nucleic acid testing has revolutionized the diagnosis of pertussis in the clinical microbiology laboratory and has become the main avenue of testing for pertussis infection. Real-time polymerase chain reaction (RT-PCR is an important tool for timely diagnosis of pertussis and is more sensitive than culture. The most commonly amplified targets are the insertion-sequence (IS genes, which are found in multiple copies in the genome of Bordetella species. Some strains of Bordetella pertussis have more than 200 copies of IS481 in their genome. This high number of repeats allows RT-PCR assays to be very sensitive and makes nucleic acid testing two to three times more sensitive than culture. Despite these advantages, RT-PCR can give inaccurate results due to contamination or lack of specificity. Contamination can easily happen during specimen collection, DNA extraction, or nucleic acid amplification steps. To avoid contamination, laboratories need to have quality controls and good workflows in place. The poor specificity of the nucleic acid assays amplifying the IS genes is because they are found in various Bordetella species and, thus, not unique to a specific species. Bordetella holmesii, a more recently described Bordetella species found to be responsible for respiratory symptoms similar to pertussis in adolescents and adults, can be misidentified as B. pertussis in RT-PCR assays that amplify only the IS481 target. Use of multiple targets may improve specificity of RT-PCR assays for pertussis. In the past few years, the US Food and Drug Administration has cleared three commercial assays for the detection of B. pertussis in respiratory specimens. Several commercial assays and analyte-specific reagents, which are not US Food and Drug Administration cleared, are available for the detection of one

  19. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study

    DEFF Research Database (Denmark)

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan

    2011-01-01

    the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened...... for chemical sensitivity with a standardised questionnaire dividing the participants into four severity groups of chemical sensitivity. Both allergic and non-allergic cutaneous reactions--defined as irritative, follicular, or doubtful allergic reactions--were analysed in relationship with severity of chemical...... most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0...

  20. Long-term retention of a divided attention psycho-motor test combining choice reaction test and postural balance test: A preliminary study.

    Science.gov (United States)

    Rossi, R; Pascolo, P B

    2015-09-01

    Driving in degraded psychophysical conditions, such as under the influence of alcohol or drugs but also in a state of fatigue or drowsiness, is a growing problem. The current roadside tests used for detecting drugs from drivers suffer various limitations, while impairment is subjective and does not necessarily correlate with drug metabolite concentration found in body fluids. This work is a validation step towards the study of feasibility of a novel test conceived to assess psychophysical conditions of individuals performing at-risk activities. Motor gestures, long-term retention and learning phase related to the protocol are analysed in unimpaired subjects. The protocol is a divided attention test, which combines a critical tracking test achieved with postural movements and a visual choice reaction test. Ten healthy subjects participated in a first set of trials and in a second set after about six months. Each session required the carrying out of the test for ten times in order to investigate learning effect and performance over repetitions. In the first set the subjects showed a learning trend up to the third trial, whilst in the second set of trials they showed motor retention. Nevertheless, the overall performance did not significantly improve. Gestures are probably retained due to the type of tasks and the way in which the instructions are conveyed to the subjects. Moreover, motor retention after a short training suggests that the protocol is easy to learn and understand. Implications for roadside test usage and comparison with current tests are also discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. PL-PatchSurfer: a novel molecular local surface-based method for exploring protein-ligand interactions.

    Science.gov (United States)

    Hu, Bingjie; Zhu, Xiaolei; Monroe, Lyman; Bures, Mark G; Kihara, Daisuke

    2014-08-27

    Structure-based computational methods have been widely used in exploring protein-ligand interactions, including predicting the binding ligands of a given protein based on their structural complementarity. Compared to other protein and ligand representations, the advantages of a surface representation include reduced sensitivity to subtle changes in the pocket and ligand conformation and fast search speed. Here we developed a novel method named PL-PatchSurfer (Protein-Ligand PatchSurfer). PL-PatchSurfer represents the protein binding pocket and the ligand molecular surface as a combination of segmented surface patches. Each patch is characterized by its geometrical shape and the electrostatic potential, which are represented using the 3D Zernike descriptor (3DZD). We first tested PL-PatchSurfer on binding ligand prediction and found it outperformed the pocket-similarity based ligand prediction program. We then optimized the search algorithm of PL-PatchSurfer using the PDBbind dataset. Finally, we explored the utility of applying PL-PatchSurfer to a larger and more diverse dataset and showed that PL-PatchSurfer was able to provide a high early enrichment for most of the targets. To the best of our knowledge, PL-PatchSurfer is the first surface patch-based method that treats ligand complementarity at protein binding sites. We believe that using a surface patch approach to better understand protein-ligand interactions has the potential to significantly enhance the design of new ligands for a wide array of drug-targets.

  2. Improvement and test calculation on basic code or sodium-water reaction jet

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Yoshinori; Itooka, Satoshi [Advanced Reactor Engineering Center, Hitachi Works, Hitachi Ltd., Hitachi, Ibaraki (Japan); Okabe, Ayao; Fujimata, Kazuhiro; Sakurai, Tomoo [Consulting Engineering Dept., Hitachi Engineering Co., Ltd., Hitachi, Ibaraki (Japan)

    1999-03-01

    In selecting the reasonable DBL (design basis water leak rate) on steam generator (SG), it is necessary to improve analytical method for estimating the sodium temperature on failure propagation due to overheating. Improvement on the basic code for sodium-water reaction (SWR) jet was performed for an actual scale SG. The improvement points of the code are as follows; (1) introduction of advanced model such as heat transfer between the jet and structure (tube array), cooling effect of the structure, heat transfer between analytic cells, and (2) model improvement for heat transfer between two-phase flow and porous-media. The test calculation using the improved code (LEAP-JET ver.1.30) were carried out with conditions of the SWAT-3{center_dot}Run-19 test and an actual scale SG. It is confirmed that the SWR jet behavior on the results is reasonable and Influence to analysis result of a model. Code integration with the blow down analytic code (LEAP-BLOW) was also studied. It is suitable that LEAP-JET was improved as one of the LEAP-BLOW's models, and it was integrated into this. In addition to above, the improvement for setting of boundary condition and the development of the interface program to transfer the analytical results of LEAP-BLOW have been performed in order to consider the cooling effect of coolant in the tube simply. However, verification of the code by new SWAT-1 and SWAT-3 test data planned in future is necessary because LEAP-JET is under development. And furthermore advancement needs to be planned. (author)

  3. Improvement and test calculation on basic code or sodium-water reaction jet

    International Nuclear Information System (INIS)

    Saito, Yoshinori; Itooka, Satoshi; Okabe, Ayao; Fujimata, Kazuhiro; Sakurai, Tomoo

    1999-03-01

    In selecting the reasonable DBL (design basis water leak rate) on steam generator (SG), it is necessary to improve analytical method for estimating the sodium temperature on failure propagation due to overheating. Improvement on the basic code for sodium-water reaction (SWR) jet was performed for an actual scale SG. The improvement points of the code are as follows; (1) introduction of advanced model such as heat transfer between the jet and structure (tube array), cooling effect of the structure, heat transfer between analytic cells, and (2) model improvement for heat transfer between two-phase flow and porous-media. The test calculation using the improved code (LEAP-JET ver.1.30) were carried out with conditions of the SWAT-3·Run-19 test and an actual scale SG. It is confirmed that the SWR jet behavior on the results is reasonable and Influence to analysis result of a model. Code integration with the blow down analytic code (LEAP-BLOW) was also studied. It is suitable that LEAP-JET was improved as one of the LEAP-BLOW's models, and it was integrated into this. In addition to above, the improvement for setting of boundary condition and the development of the interface program to transfer the analytical results of LEAP-BLOW have been performed in order to consider the cooling effect of coolant in the tube simply. However, verification of the code by new SWAT-1 and SWAT-3 test data planned in future is necessary because LEAP-JET is under development. And furthermore advancement needs to be planned. (author)

  4. Temporary patching of damaged UF{sub 6} cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas, A.L. [Martin Marietta Energy Systems, Inc., OH (United States)

    1991-12-31

    Patching techniques based on application of epoxy resins have been developed for temporarily repairing UF{sub 6} cylinders which have sustained relatively minor damage and must be safely emptied. The method is considerably faster and simpler than metallurgical weld repairs. Laboratory tests, detailed operational procedures, and case histories of experience at the Portsmouth Gaseous Diffusion Plant are described.

  5. Patch testing with methylchloroisothiazolinone/methylisothiazolinone 200 ppm aq. detects significantly more contact allergy than 100 ppm. A multicentre study within the European Environmental and Contact Dermatitis Research Group

    DEFF Research Database (Denmark)

    Bruze, Magnus; Isaksson, Marléne; Gruvberger, Birgitta

    2014-01-01

    , and that for IQ Chambers(®) was 25 µl. RESULTS: Contact allergy to MCI/MI at 100 and 200 ppm was found in 1.2% and 2.1% of patients, respectively (p more contact allergy than the presently used concentration of 100 ppm (dose...... 0.003 mg/cm(2)), without resulting in more adverse reactions. MCI/MI at 200 ppm should therefore be considered for inclusion in the European baseline test series....

  6. Slime moulds use heuristics based on within-patch experience to decide when to leave.

    Science.gov (United States)

    Latty, Tanya; Beekman, Madeleine

    2015-04-15

    Animals foraging in patchy, non-renewing or slowly renewing environments must make decisions about how long to remain within a patch. Organisms can use heuristics ('rules of thumb') based on available information to decide when to leave the patch. Here, we investigated proximate patch-departure heuristics in two species of giant, brainless amoeba: the slime moulds Didymium bahiense and Physarum polycephalum. We explicitly tested the importance of information obtained through experience by eliminating chemosensory cues of patch quality. In P. polycephalum, patch departure was influenced by the consumption of high, and to a much lesser extent low, quality food items such that engulfing a food item increased patch-residency time. Physarum polycephalum also tended to forage for longer in darkened, 'safe' patches. In D. bahiense, engulfment of any food item increased patch residency irrespective of that food item's quality. Exposure to light had no effect on the patch-residency time of D. bahiense. Given that these organisms lack a brain, our results illustrate how the use of simple heuristics can give the impression that individuals make sophisticated foraging decisions. © 2015. Published by The Company of Biologists Ltd.

  7. Reaction-to-Fire of Wood Products and Other Building Materials: Part 1, Room/Corner Test Performance

    Science.gov (United States)

    Ondrej Grexa; Mark A. Dietenberger; Robert H. White

    2012-01-01

    This project researched the assessment of reaction-to-fire of common materials using the full-scale room/corner test (ISO 9705) protocol and the predictions of time to flashover using results from the bench-scale cone calorimeter test (ISO 5660-1). Using a burner protocol of 100 kW for 10 min, followed by 300 kW for 10 min and the test materials on the walls only, we...

  8. Calculation of the energy of explosives with a partial reaction model. Comparison with cylinder test data

    Energy Technology Data Exchange (ETDEWEB)

    Sanchidrian, Jose A.; Lopez, Lina M. [Universidad Politecnica de Madrid - E.T.S.I. Minas, Rios Rosas 21, E-28003 Madrid (Spain)

    2006-02-15

    The energy delivered by explosives is described by means of the useful expansion work along the isentrope of the detonation products. A thermodynamic code (W-DETCOM) is used, in which a partial reaction model has been implemented. In this model, the reacted fraction of the explosive in the detonation state is used as a fitting factor so that the calculated detonation velocity meets the experimental value. Calculations based on such a model have been carried out for a number of commercial explosives of ANFO and emulsion types. The BKW (Becker-Kistiakowsky-Wilson) equation of state is used for the detonation gases with the Sandia parameter set (BKWS). The energy delivered in the expansion (useful work) is calculated, and the values obtained are compared with the Gurney energies from cylinder test data at various expansion ratios. The expansion work values obtained are much more realistic than those from an ideal detonation calculation and, in most cases, the values predicted by the calculation are in good agreement with the experimental ones. (Abstract Copyright [2006], Wiley Periodicals, Inc.)

  9. Reaction-in-flight neutrons as a test of stopping power in degenerate plasmas

    Science.gov (United States)

    Hayes, A. C.; Jungman, Gerard; Schulz, A. E.; Boswell, M.; Fowler, M. M.; Grim, G.; Klein, A.; Rundberg, R. S.; Wilhelmy, J. B.; Wilson, D.; Cerjan, C.; Schneider, D.; Sepke, S. M.; Tonchev, A.; Yeamans, C.

    2015-08-01

    We present the first measurements of reaction-in-flight (RIF) neutrons in an inertial confinement fusion system. The experiments were carried out at the National Ignition Facility, using both Low Foot and High Foot drives and cryogenic plastic capsules. In both cases, the high-energy RIF ( En> 15 MeV) component of the neutron spectrum was found to be about 10-4 of the total. The majority of the RIF neutrons were produced in the dense cold fuel surrounding the burning hotspot of the capsule, and the data are consistent with a compressed cold fuel that is moderately to strongly coupled (Γ˜ 0.6) and electron degenerate (θFermi/θe˜ 4). The production of RIF neutrons is controlled by the stopping power in the plasma. Thus, the current RIF measurements provide a unique test of stopping power models in an experimentally unexplored plasma regime. We find that the measured RIF data strongly constrain stopping models in warm dense plasma conditions, and some models are ruled out by our analysis of these experiments.

  10. Testing an ionization chamber with gaseous samples and measurements of the (n, alpha) reaction cross sections

    CERN Document Server

    Gledenov, Yu M; Salatskii, V I; Sedyshev, P V; Andrzejewski, J; Szalanski, P

    1999-01-01

    A new ionization chamber with gaseous samples (GIC) has been designed and tested on the thermal and resonance neutron beams of FLNP's neutron sources. The exposed gas volume serves as a target for neutrons. The obtained thermal cross sections for the sup 1 sup 7 O(n, alpha) sup 1 sup 4 C, sup 2 sup 1 Ne(n, alpha) sup 1 sup 8 O and sup 3 sup 6 Ar(n, alpha) sup 3 sup 3 S reactions are (233+-12) mb, (0.18+-0.09) mb and (5.43+-0.27) mb, respectively. These measurements have been performed on a pure beam of thermal neutrons from the high flux reactor IBR-2; and they demonstrated high efficiency and reliability of the method. Compared to samples on substrates, the application of gaseous samples makes the beam background essentially lower, and what is more important, the background component is totally absent due to the absence of Li and B microimpurities in gaseous samples while they do present in the samples on substrates. The method is also applicable to measurements with resonance neutrons. The recovery capabili...

  11. Smart thermal patch for adaptive thermotherapy

    KAUST Repository

    Hussain, Muhammad Mustafa

    2015-11-12

    A smart thermal patch for adaptive thermotherapy is provided. In an embodiment, the patch can be a stretchable, non-polymeric, conductive thin film flexible and non-invasive body integrated mobile thermal heater with wireless control capabilities that can be used to provide adaptive thermotherapy. The patch can be geometrically and spatially tunable on various pain locations. Adaptability allows the amount of heating to be tuned based on the temperature of the treated portion.

  12. Patch layout generation by detecting feature networks

    KAUST Repository

    Cao, Yuanhao

    2015-02-01

    The patch layout of 3D surfaces reveals the high-level geometric and topological structures. In this paper, we study the patch layout computation by detecting and enclosing feature loops on surfaces. We present a hybrid framework which combines several key ingredients, including feature detection, feature filtering, feature curve extension, patch subdivision and boundary smoothing. Our framework is able to compute patch layouts through concave features as previous approaches, but also able to generate nice layouts through smoothing regions. We demonstrate the effectiveness of our framework by comparing with the state-of-the-art methods.

  13. Collection of analytes from microneedle patches.

    Science.gov (United States)

    Romanyuk, Andrey V; Zvezdin, Vasiliy N; Samant, Pradnya; Grenader, Mark I; Zemlyanova, Marina; Prausnitz, Mark R

    2014-11-04

    Clinical medicine and public health would benefit from simplified acquisition of biological samples from patients that can be easily obtained at point of care, in the field, and by patients themselves. Microneedle patches are designed to serve this need by collecting dermal interstitial fluid containing biomarkers without the dangers, pain, or expertise needed to collect blood. This study presents novel methods to collect biomarker analytes from microneedle patches for analysis by integration into conventional analytical laboratory microtubes and microplates. Microneedle patches were made out of cross-linked hydrogel composed of poly(methyl vinyl ether-alt-maleic acid) and poly(ethylene glycol) prepared by micromolding. Microneedle patches were shown to swell with water up to 50-fold in volume, depending on degree of polymer cross-linking, and to collect interstitial fluid from the skin of rats. To collect analytes from microneedle patches, the patches were mounted within the cap of microcentrifuge tubes or formed the top of V-bottom multiwell microplates, and fluid was collected in the bottom of the tubes under gentle centrifugation. In another method, microneedle patches were attached to form the bottom of multiwell microplates, thereby enabling in situ analysis. The simplicity of biological sample acquisition using microneedle patches coupled with the simplicity of analyte collection from microneedles patches integrated into conventional analytical equipment could broaden the reach of future screening, diagnosis, and monitoring of biomarkers in healthcare and environmental/workplace settings.

  14. Allergy testing - skin

    Science.gov (United States)

    Patch tests - allergy; Scratch tests - allergy; Skin tests - allergy; RAST test; Allergic rhinitis - allergy testing; Asthma - allergy testing; Eczema - allergy testing; Hayfever - allergy testing; Dermatitis - allergy testing; Allergy testing; ...

  15. Persistent Skin Reactions and Aluminium Hypersensitivity Induced by Childhood Vaccines.

    Science.gov (United States)

    Salik, Elaha; Løvik, Ida; Andersen, Klaus E; Bygum, Anette

    2016-11-02

    There is increasing awareness of reactions to vaccination that include persistent skin reactions. We present here a retrospective investigation of long-lasting skin reactions and aluminium hypersensitivity in children, based on medical records and questionnaires sent to the parents. In the 10-year period 2003 to 2013 we identified 47 children with persistent skin reactions caused by childhood vaccinations. Most patients had a typical presentation of persisting pruritic subcutaneous nodules. Five children had a complex diagnostic process involving paediatricians, orthopaedics and plastic surgeons. Two patients had skin biopsies performed from their skin lesions, and 2 patients had the nodules surgically removed. Forty-two children had a patch-test performed with 2% aluminium chloride hexahydrate in petrolatum and 39 of them (92%) had a positive reaction. The persistent skin reactions were treated with potent topical corticosteroids and disappeared slowly. Although we advised families to continue vaccination of their children, one-third of parents omitted or postponed further vaccinations.

  16. Microstrip patch antenna for simultaneous strain and temperature sensing

    Science.gov (United States)

    Mbanya Tchafa, F.; Huang, H.

    2018-06-01

    A patch antenna, consisting of a radiation patch, a dielectric substrate, and a ground plane, resonates at distinct fundamental frequencies that depend on the substrate dielectric constant and the dimensions of the radiation patch. Since these parameters change with the applied strain and temperature, this study investigates simultaneous strain and temperature sensing using a single antenna that has two fundamental resonant frequencies. The theoretical relationship between the antenna resonant frequency shifts, the temperature, and the applied strain was first established to guide the selection of the dielectric substrate, based on which an antenna sensor with a rectangular radiation patch was designed and fabricated. A tensile test specimen instrumented with the antenna sensor was subjected to thermo-mechanical tests. Experiment results validated the theoretical predictions that the normalized antenna resonant frequency shifts are linearly proportional to the applied strain and temperature changes. An inverse method was developed to determine the strain and temperature changes from the normalized antenna resonant frequency shifts, yielding measurement uncertainty of 0.4 °C and 17.22 μ \\varepsilon for temperature and strain measurement, respectively.

  17. Reactions to merit pay increases: a longitudinal test of a signal sensitivity perspective.

    Science.gov (United States)

    Shaw, Jason D; Duffy, Michelle K; Mitra, Atul; Lockhart, Daniel E; Bowler, Matthew

    2003-06-01

    The relationships among merit pay raises, trait positive affectivity (PA), and reactions to merit pay increases (pay attitudes and behavioral intentions) were explored in a longitudinal study of hospital employees. Drawing on signal sensitivity theory, the authors expected that PA would moderate the relationship between merit pay raise size and reactions to the increase such that pay raise size would be more strongly related to pay attitudes and behavioral intentions among those low in PA. Results strongly supported the predictions in the case of reactions to the raise amount (happiness and effort intentions) but not for pay level satisfaction. Implications of the results and directions for future research are identified.

  18. Thougths Emerged From the Anaphylactic Reactions Due to Fresh Prict Test with Fruit; are We Aware of the Potantial Danger?

    Directory of Open Access Journals (Sweden)

    Ali Kutlu

    2014-10-01

    Full Text Available Basic approach for food allergy is to avoide taking the food which is known to be allergic to the person. Minimal contact with allergen even such as skin prict test may also trigger the severe anaphylactic reactions. We want to share our exprience about a patient who exprienced anaphylaxis after fresh prick allergy skin test with fresh fruit (peach, apricot, plumb that we performed in our clinic. We belive that the patients who are known to have severe allergic reaction story must avoid to work in food proccesing and storage works, in case any contact with wounded skin area may result in severe allergic reaction [TAF Prev Med Bull 2014; 13(5.000: 435-436

  19. Explaining reactions to normative information about alcohol consumption: a test of an extended social identity model.

    Science.gov (United States)

    Livingstone, Andrew G; McCafferty, Stephanie

    2015-04-01

    To test the role of group identification and the perceived importance of alcohol consumption to a group identity in shaping reactions to normative information about alcohol consumption. The study had a 2 (behaviour: identity-defining/alcohol vs. non-identity defining/caffeine) × 2 (norm: low vs. heavy consumption) between-subjects factorial design. Group identification and personal attitudes towards alcohol/caffeine consumption were included as measured predictors. Participants were 83 undergraduate students (44 female, 38 male, one unspecified) at a University in Scotland. Predictor and outcome variables included questionnaire measures of group (student) identification, personal attitudes to alcohol/caffeine consumption, the perceived importance of alcohol/caffeine consumption to group identity, and behavioral intentions to consume alcohol/caffeine. Personal attitude and group identification moderated the impact of norm information on consumption intentions, but only for alcohol consumption, and not caffeine consumption. For alcohol, norm information did affect intended consumption (ps ≤ .034), with the crucial exception of high identifiers who had favourable personal attitudes towards alcohol consumption. Instead, these individuals resist norm information (ps = .458 and .174), showing no decrease in intentions in the face of norm information that emphasised relatively 'low' levels of consumption. The impact of norm information on alcohol consumption intentions depends on group-based factors such as group identification and the perceived importance of alcohol to a group identity. When both of these factors are high, and an individual also personally favours the behaviour, the potential for norm-based interventions to fail is increased. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Implementation of secondary bacterial culture testing of platelets to mitigate residual risk of septic transfusion reactions.

    Science.gov (United States)

    Bloch, Evan M; Marshall, Christi E; Boyd, Joan S; Shifflett, Lisa; Tobian, Aaron A R; Gehrie, Eric A; Ness, Paul M

    2018-04-01

    Bacterial contamination of platelets remains a major transfusion-associated risk despite long-standing safety measures in the United States. We evaluated an approach using secondary bacterial culture (SBC) to contend with residual risk of bacterial contamination. Phased implementation of SBC was initiated in October 2016 for platelets (all apheresis collected) received at our institution from the blood donor center (Day 3 post collection). Platelet products were sampled aseptically (5 mL inoculated into an aerobic bottle [BacT/ALERT BPA, BioMerieux, Inc.]) by the blood bank staff upon receipt, using a sterile connection device and sampling kit. The platelet sample was inoculated into an aerobic blood culture bottle and incubated at 35°C for 3 days. The cost of SBC was calculated on the basis of consumables and labor costs at time of implementation. In the 13 months following implementation (October 6, 2016, to November 30, 2017), 23,044/24,653 (93.47%) platelet products underwent SBC. A total of eight positive cultures were detected (incidence 1 in 2881 platelet products), seven of which were positive within 24 hours of SBC. Coagulase negative Staphyloccus spp. were identified in four cases. Five of the eight cases were probable true positive (repeat reactive) and interdicted (cost per averted case was US$77,935). The remaining three cases were indeterminate. No septic transfusion reactions were reported during the observation period. We demonstrate the feasibility of SBC of apheresis platelets to mitigate bacterial risk. SBC is lower cost than alternative measures (e.g., pathogen reduction and point-of-release testing) and can be integrated into workflow at hospital transfusion services. © 2018 AABB.

  1. 9 CFR 147.30 - Laboratory procedure recommended for the polymerase chain reaction (PCR) test for Mycoplasma...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Laboratory procedure recommended for... Examination Procedures § 147.30 Laboratory procedure recommended for the polymerase chain reaction (PCR) test... tracheal swabs in PBS or 1 mL of broth culture by a non-phenolic procedure. Centrifuge samples at 14,000 x...

  2. Test of supersymmetry in the 193Ir→194Pt proton stripping reactions

    International Nuclear Information System (INIS)

    Vergnes, M.; Rotbard, G.; Kalifa, J.; Berrier-Ronsin, G.; Vernotte, J.; Seltz, R.; Burke, D.G.

    1980-01-01

    A breakdown of the selection rules of the supersymmetry model is observed for the population of the 0 2 + and 2 2 + levels of 194 Pt in the 193 Ir → 194 Pt proton stripping reactions performed using the Orsay and Mc Master University tandem accelerators. The existence of other violations in the neighbouring nuclei leads to believe that we are seeing the limitations of the supersymmetry scheme itself, at least for particle transfer reactions

  3. Transdermal patches: history, development and pharmacology

    Science.gov (United States)

    Pastore, Michael N; Kalia, Yogeshvar N; Horstmann, Michael; Roberts, Michael S

    2015-01-01

    Transdermal patches are now widely used as cosmetic, topical and transdermal delivery systems. These patches represent a key outcome from the growth in skin science, technology and expertise developed through trial and error, clinical observation and evidence-based studies that date back to the first existing human records. This review begins with the earliest topical therapies and traces topical delivery to the present-day transdermal patches, describing along the way the initial trials, devices and drug delivery systems that underpin current transdermal patches and their actives. This is followed by consideration of the evolution in the various patch designs and their limitations as well as requirements for actives to be used for transdermal delivery. The properties of and issues associated with the use of currently marketed products, such as variability, safety and regulatory aspects, are then described. The review concludes by examining future prospects for transdermal patches and drug delivery systems, such as the combination of active delivery systems with patches, minimally invasive microneedle patches and cutaneous solutions, including metered-dose systems. PMID:25560046

  4. Immunoisolation Patch System for Cellular Transplantation

    Science.gov (United States)

    Wang, Taylor G. (Inventor)

    2014-01-01

    An immunoisolation patch system, and particularly a patch system comprising multiple immunoisolation microcapsules, each encapsulating biological material such as cells for transplantation, which can be used in the prophylactic and therapeutic treatment of disease in large animals and humans without the need for immunosuppression.

  5. Compatibility of Clinical Manifestation with Skin Prick Test Result and Food Provocation Test in Food Cross Reaction

    OpenAIRE

    Lubis, Azwin; Barlianto, Wisnu; Endaryanto, Anang; Harsono, Ariyanto

    2017-01-01

    Background: Subjective diagnostic test of food allergy is hugely biased, resulting in irrational diet avoidance. Additional objective tools by skin prick test following food provocation test resulting more accurate cause and prevalence on population. Purpose: To evaluate the compatibility of clinical symptoms with skin prick test and provocation test for imunoglobulin E (IgE) mediated food allergy in Dr. Soetomo Hospital Surabaya. Methods: Cross sectional observational analytic study. Patient...

  6. Quantitative assessment of alkali silica reaction potential of quartz-rich aggregates: comparison of chemical test and accelerated mortar bar test improved by SEM-PIA

    Czech Academy of Sciences Publication Activity Database

    Šachlová, Š.; Kuchařová, A.; Pertold, Z.; Přikryl, R.; Fridrichová, Michaela

    2017-01-01

    Roč. 76, č. 1 (2017), s. 133-144 ISSN 1435-9529 R&D Projects: GA ČR(CZ) GAP104/12/0915 Institutional support: RVO:67985831 Keywords : accelerated mortar bar test * Alkali silica reaction * chemical test * electron microscopy * petrographic image analysis Subject RIV: DD - Geochemistry OBOR OECD: Environmental and geological engineering , geotechnics Impact factor: 1.901, year: 2016

  7. Performance test results of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2003-03-01

    Research on a hydrogen production system by steam reforming of methane, chemical reaction; CH{sub 4} + H{sub 2}O {yields} 3H{sub 2}O + CO, has been carried out to couple with the HTTR for establishment of high-temperature nuclear heat utilization technology and contribution to hydrogen energy society in future. The mock-up test facility with a full-scale reaction tube test facility, a model simulating one reaction tube of a steam reformer of the HTTR hydrogen production system in full scale, was fabricated to perform tests on controllability, hydrogen production performance etc. under the same pressure and temperature conditions as those of the HTTR hydrogen production system. The design and fabrication of the test facility started from 1997, and the all components were installed until September in 2001. In a performance test conducted from October in 2001 to February in 2002, performance of each component was examined and hydrogen of 120m{sup 3}{sub N}/h was successfully produced with high-temperature helium gas. This report describes the performance test results on components performance, hydrogen production characteristics etc., and main troubles and countermeasures. (author)

  8. Performance test results of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system. Contract research

    International Nuclear Information System (INIS)

    Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio

    2003-03-01

    Research on a hydrogen production system by steam reforming of methane, chemical reaction; CH 4 + H 2 O → 3H 2 O + CO, has been carried out to couple with the HTTR for establishment of high-temperature nuclear heat utilization technology and contribution to hydrogen energy society in future. The mock-up test facility with a full-scale reaction tube test facility, a model simulating one reaction tube of a steam reformer of the HTTR hydrogen production system in full scale, was fabricated to perform tests on controllability, hydrogen production performance etc. under the same pressure and temperature conditions as those of the HTTR hydrogen production system. The design and fabrication of the test facility started from 1997, and the all components were installed until September in 2001. In a performance test conducted from October in 2001 to February in 2002, performance of each component was examined and hydrogen of 120m 3 N /h was successfully produced with high-temperature helium gas. This report describes the performance test results on components performance, hydrogen production characteristics etc., and main troubles and countermeasures. (author)

  9. Effects of Spatial Patch Arrangement and Scale of Covarying Resources on Growth and Intraspecific Competition of a Clonal Plant.

    Science.gov (United States)

    Wang, Yong-Jian; Shi, Xue-Ping; Meng, Xue-Feng; Wu, Xiao-Jing; Luo, Fang-Li; Yu, Fei-Hai

    2016-01-01

    Spatial heterogeneity in two co-variable resources such as light and water availability is common and can affect the growth of clonal plants. Several studies have tested effects of spatial heterogeneity in the supply of a single resource on competitive interactions of plants, but none has examined those of heterogeneous distribution of two co-variable resources. In a greenhouse experiment, we grew one (without intraspecific competition) or nine isolated ramets (with competition) of a rhizomatous herb Iris japonica under a homogeneous environment and four heterogeneous environments differing in patch arrangement (reciprocal and parallel patchiness of light and soil water) and patch scale (large and small patches of light and water). Intraspecific competition significantly decreased the growth of I. japonica, but at the whole container level there were no significant interaction effects of competition by spatial heterogeneity or significant effect of heterogeneity on competitive intensity. Irrespective of competition, the growth of I. japonica in the high and the low water patches did not differ significantly in the homogeneous treatments, but it was significantly larger in the high than in the low water patches in the heterogeneous treatments with large patches. For the heterogeneous treatments with small patches, the growth of I. japonica was significantly larger in the high than in the low water patches in the presence of competition, but such an effect was not significant in the absence of competition. Furthermore, patch arrangement and patch scale significantly affected competitive intensity at the patch level. Therefore, spatial heterogeneity in light and water supply can alter intraspecific competition at the patch level and such effects depend on patch arrangement and patch scale.

  10. Image quality assessment based on inter-patch and intra-patch similarity.

    Directory of Open Access Journals (Sweden)

    Fei Zhou

    Full Text Available In this paper, we propose a full-reference (FR image quality assessment (IQA scheme, which evaluates image fidelity from two aspects: the inter-patch similarity and the intra-patch similarity. The scheme is performed in a patch-wise fashion so that a quality map can be obtained. On one hand, we investigate the disparity between one image patch and its adjacent ones. This disparity is visually described by an inter-patch feature, where the hybrid effect of luminance masking and contrast masking is taken into account. The inter-patch similarity is further measured by modifying the normalized correlation coefficient (NCC. On the other hand, we also attach importance to the impact of image contents within one patch on the IQA problem. For the intra-patch feature, we consider image curvature as an important complement of image gradient. According to local image contents, the intra-patch similarity is measured by adaptively comparing image curvature and gradient. Besides, a nonlinear integration of the inter-patch and intra-patch similarity is presented to obtain an overall score of image quality. The experiments conducted on six publicly available image databases show that our scheme achieves better performance in comparison with several state-of-the-art schemes.

  11. Relative abundance of mesopredators and size of oak patches in the cross-timbers ecoregion

    Science.gov (United States)

    Disney, M.R.; Hellgren, E.C.; Davis, C.A.; Leslie, David M.; Engle, David M.

    2008-01-01

    Mesopredators (e.g., raccoon Procyon lotor, Virginia opossum Didelphis virginiana, striped skunk Mephitis mephitis) have received considerable attention because of links to population declines in birds via increased nest predation, especially in landscapes fragmented by anthropogenic forces. Relationships of abundance of mesopredators to size of habitat patches have received less attention than relationships to other metrics of fragmentation, particularly edge characteristics. We tested the hypothesis that relative abundance of mesopredators (e.g., raccoons and Virginia opossums) was related negatively to size of forest patch. We delineated 15 patches of oak (Quercus) forest ranging from 0.2 to 55.3 ha within a grassland-woodland mosaic in the cross-timbers ecoregion of Oklahoma. Scent stations and live traps within these patches were used to index relative abundance of mesopredators in summers 2003 and 2004. Both indices of relative abundance were related weakly and negatively to area of forest patch. However, rate of capture and visitation to scent station were not correlated consistently throughout the study. Our results suggested that the two methods to index abundance provided separate information on functional and numerical responses to size of patch. Our evidence that mesopredators within the cross timbers were more likely to be in smaller patches of oak forest may have implications to success of avian nesting in these patches.

  12. Temperature escalation in PWR fuel rod simulators due to the zircaloy/steam reaction: Tests ESSI-1,2,3

    International Nuclear Information System (INIS)

    Hagen, S.; Malauschek, H.; Wallenfels, K.P.; Peck, S.O.

    1983-08-01

    This report discusses the test conduct, results, and posttest appearance of three scoping tests (ESSI-1,2,3) investigating temperature escalation in zircaloy clad fuel rods. The experiments are part of an out-of-pile program using electrically heated fuel rod simulators to investigate PWR fuel element behavior up to temperatures of 2000 0 C. These experiments are part of the PNS Severe Fuel Damage Program. The temperature escalation is caused by the exothermal zircaloy/steam reaction, whose reaction rate increases exponentially with the temperature. The tests were performed using different initial oxide layers as a major parameter, obtained by varying the heatup rates and steam exposure times. (orig./RW) [de

  13. Development and testing of a compartmentalized reaction network model for redox zones in contaminated aquifers

    Science.gov (United States)

    Abrams , Robert H.; Loague, Keith; Kent, Douglas B.

    1998-01-01

    The work reported here is the first part of a larger effort focused on efficient numerical simulation of redox zone development in contaminated aquifers. The sequential use of various electron acceptors, which is governed by the energy yield of each reaction, gives rise to redox zones. The large difference in energy yields between the various redox reactions leads to systems of equations that are extremely ill-conditioned. These equations are very difficult to solve, especially in the context of coupled fluid flow, solute transport, and geochemical simulations. We have developed a general, rational method to solve such systems where we focus on the dominant reactions, compartmentalizing them in a manner that is analogous to the redox zones that are often observed in the field. The compartmentalized approach allows us to easily solve a complex geochemical system as a function of time and energy yield, laying the foundation for our ongoing work in which we couple the reaction network, for the development of redox zones, to a model of subsurface fluid flow and solute transport. Our method (1) solves the numerical system without evoking a redox parameter, (2) improves the numerical stability of redox systems by choosing which compartment and thus which reaction network to use based upon the concentration ratios of key constituents, (3) simulates the development of redox zones as a function of time without the use of inhibition factors or switching functions, and (4) can reduce the number of transport equations that need to be solved in space and time. We show through the use of various model performance evaluation statistics that the appropriate compartment choice under different geochemical conditions leads to numerical solutions without significant error. The compartmentalized approach described here facilitates the next phase of this effort where we couple the redox zone reaction network to models of fluid flow and solute transport.

  14. A Small-Scale Capsule Test for Investigating the Sodium-Carbon Dioxide Reaction

    International Nuclear Information System (INIS)

    Kim, B. H.; Choi, J. H.; Suk, S. D.; Kim, J. M.; Choi, B. H.; Kim, B. H.; Hahn, D. H.

    2007-01-01

    The utilization of modular sodium-to-supercritical CO 2 heat exchangers may yield significant improvements for an overall plant energy utilization. The consequences of a failure of the sodium CO 2 heat exchanger boundary, however, would involve the blowdown and intermixing of high-pressure CO 2 in a sodium pool, causing a pressurization which may threaten the structural integrity of the heat exchanger. Available data seems to indicate that the chemical reaction between sodium and CO 2 would likely produce sodium oxides, sodium carbonate, carbon and carbon monoxide. Information on the kinetics of the sodium-CO 2 reaction is virtually non-existent

  15. The demand for pregnancy testing: The Aschheim–Zondek reaction, diagnostic versatility, and laboratory services in 1930s Britain

    Science.gov (United States)

    Olszynko-Gryn, Jesse

    2014-01-01

    The Aschheim–Zondek reaction is generally regarded as the first reliable hormone test for pregnancy and as a major product of the ‘heroic age’ of reproductive endocrinology. Invented in Berlin in the late 1920s, by the mid 1930s a diagnostic laboratory in Edinburgh was performing thousands of tests every year for doctors around Britain. In her classic history of antenatal care, sociologist Ann Oakley claimed that the Aschheim–Zondek test launched a ‘modern era’ of obstetric knowledge, which asserted its superiority over that of pregnant women. This article reconsiders Oakley’s claim by examining how pregnancy testing worked in practice. It explains the British adoption of the test in terms less of the medicalisation of pregnancy than of clinicians’ increasing general reliance on laboratory services for differential diagnosis. Crucially, the Aschheim–Zondek reaction was a test not directly for the fetus, but for placental tissue. It was used, less as a yes-or-no test for ordinary pregnancy, than as a versatile diagnostic tool for the early detection of malignant tumours and hormonal deficiencies believed to cause miscarriage. This test was as much a product of oncology and the little-explored world of laboratory services as of reproductive medicine. PMID:24388014

  16. Efficacy and safety of a novel, soluble microneedle patch for the improvement of facial wrinkle.

    Science.gov (United States)

    Hong, Ji Yeon; Ko, Eun Jung; Choi, Sun Young; Li, Kapsok; Kim, A Reum; Park, Jin O; Kim, Beom Joon

    2018-04-01

    Various kinds of functional cosmetics are on the market, although there are a variety of opinions concerning the actual effect. Transdermal microneedle patch has been introduced as a newly developed device for drug delivery through the skin. This study was conducted to verify the face skin improvement effect and safety of a novel cosmetic microneedle patch. A total of 84 Korean females finished this prospective clinical trial. The subjects were divided into 3 groups: (1) soluble hyaluronic acid (HA) microneedle patch alone, (2) soluble HA microneedle patch plus adenosine wrinkle cream, and (3) adenosine wrinkle cream alone. The treatments were applied to the crow's feet and nasolabial fold wrinkle for 12 weeks. The test areas were measured before treatment and at 4, 8, and 12 weeks after use of the test product. At the completion of the testing period of the trial, the global assessment of efficacy and product preferences were surveyed from the subjects. Combination treatment with wrinkle cream and microneedle patch significantly improved Merz scale for crow's feet and nasolabial folds, compared to the sole application of wrinkle cream or patch. Measurement on the crow's feet showed an overall improvement in all 3 groups, yielding no significant differences among the groups. No serious adverse effects were observed during the follow-up period. Combination application of a soluble microneedle patch and wrinkle cream was an effective treatment in improving facial wrinkles, thus enhancing skin rejuvenation. © 2017 Wiley Periodicals, Inc.

  17. Nicotine patches in pregnant smokers: randomised, placebo controlled, multicentre trial of efficacy

    Science.gov (United States)

    Grangé, Gilles; Jacob, Nelly; Tanguy, Marie-Laure

    2014-01-01

    reported median compliance rate was 85% (interquartile range 56-99%) in the nicotine patch group and 83% (56-95%) in the placebo patch group, assessed at 1016 visits. The mean birth weight was 3065 g (SE 44 g) in the nicotine patch group and 3015 g (SE 44 g) in the placebo patch group (P=0.41). Diastolic blood pressure was significantly higher in the nicotine patch group than in the placebo patch group. The frequency of serious adverse events was similar between the groups, although more non-serious adverse reactions, mainly of skin, occurred in the nicotine patch group. Conclusion The nicotine patch did not increase either smoking cessation rates or birth weights despite adjustment of nicotine dose to match levels attained when smoking, and higher than usual doses. Trial registration ClinicalTrials.gov NCT00507975. PMID:24627552

  18. A Test of Cognitive Dissonance Theory to Explain Parents' Reactions to Youths' Alcohol Intoxication

    Science.gov (United States)

    Glatz, Terese; Stattin, Hakan; Kerr, Margaret

    2012-01-01

    Studies have shown that parents reduce control and support in response to youths' drinking. Why they react this way, however, is still unknown. From cognitive dissonance theory, we derived hypotheses about parents' reactions. We used a longitudinal, school-based sample of 494 youths (13 and 14 years, 56% boys) and their parents. General Linear…

  19. Design, Testing and Kinetic Analysis of Bulky Monodentate Phosphorus Ligands in the Mizoroki-Heck Reaction

    NARCIS (Netherlands)

    Dodds, Deborah L.; Boele, Maarten D. K.; van Strijdonck, Gino P. F.; de Vries, Johannes G.; van Leeuwen, Piet W. N. M.; Kamer, Paul C. J.

    A series of new monodentate phosphane ligands 2 have been evaluated in the MizorokiHeck arylation reaction of iodobenzene and styrene and compared with our previously reported ligands, 1, 3 and 4. The concept of rational ligand design is discussed, and we describe how the performance of this new

  20. Japanese position paper on sodium-water reaction testing and design

    International Nuclear Information System (INIS)

    Sato, M.; Hiroi, H.; Tanabe, H.; Miyake, O.; Kuroha, M.; Hoshi, Y.

    1984-01-01

    PNC has been developing the steam generator with helically coiled heat transfer tube bundle and downcommer tubes for the prototype fast reactor Monju since 1968. To establish the safety design against the sodium-water reaction accident was one of the most important R and D items at the start of the development. PNC started the experimental study initially in the large leak region in 1970. Until now, during twelve years, the experimental studies have been performed, which covers the phenomena from a micro leak to a large one, with the use of the SWAT-1 rig, SWAT-2 loop, SWAT-3 loop, and SWAT-4 rigs. The reliable leak detection system is necessary to minimize the damage by the sodium-water reaction. Two groups of efforts have been paid for developing the detection system. One is to develop the leak detector itself, and another is to grasp the hydrogen transport behavior in the sodium in the steam generator and the secondary piping system. Four sodium loops have been used for the development. The development of computer codes has also progressed in parallel with the sodium-water reaction experiments. Three codes have been accomplished for the design tools against the sodium-water reaction. Through the efforts mentioned above, sufficient experiences were obtained for designing and operating the Monju steam generator system

  1. Initial pressure spike and its propagation phenomena in sodium-water reaction tests for MONJU steam generators

    International Nuclear Information System (INIS)

    Sato, M.; Hiroi, H.; Tanaka, N.; Hori, M.

    1977-01-01

    With the objective of demonstrating the safe design of steam generators for prototype LMFBR MONJU against the postulated large-leak accident, a number of large-leak sodium-water reaction tests have been conducted using the SWAT-1 and SWAT-3 rigs. Investigation of the potential effects of pressure load on the system is one of the major concerns in these tests. This paper reports the behavior of initial pressure spike in the reaction vessel, its propagation phenomena to the simulated secondary cooling system, and the comparisons with the computer code for one-dimensional pressure wave propagation problems. Both rigs used are the scaled-down models of the helically coiled steam generators of MONJU. The SWAT-1 rig is a simplified model and consists of a reaction vessel (1/8 scale of MONJU evaporator with 0.4 m dia. and 2.5 m height) and a pressure relief system i.e., a pressure relief line and a reaction products tank. On the other hand, the SWAT-3 rig is a 1/2.5 scale of MONJU SG system and consists of an evaporator (reaction vessel with 1.3 m dia. and 6.35 m height), a superheater, an intermediate heat exchanger (IHX), a piping system simulating the secondary cooling circuit and a pressure relief system. The both water injection systems consist of a water injection line with a rupture disk installed in front of injection hole and an electrically heated water tank. Choice of water injection rates in the scaled-down models is made based on the method of iso-velocity modeling. Test results indicated that the characteristics of the initial pressure spike are dominated by those of initial water injection which are controlled by the conditions of water heater and the size of water injection hole, etc

  2. A simple test of choice stepping reaction time for assessing fall risk in people with multiple sclerosis.

    Science.gov (United States)

    Tijsma, Mylou; Vister, Eva; Hoang, Phu; Lord, Stephen R

    2017-03-01

    Purpose To determine (a) the discriminant validity for established fall risk factors and (b) the predictive validity for falls of a simple test of choice stepping reaction time (CSRT) in people with multiple sclerosis (MS). Method People with MS (n = 210, 21-74y) performed the CSRT, sensorimotor, balance and neuropsychological tests in a single session. They were then followed up for falls using monthly fall diaries for 6 months. Results The CSRT test had excellent discriminant validity with respect to established fall risk factors. Frequent fallers (≥3 falls) performed significantly worse in the CSRT test than non-frequent fallers (0-2 falls). With the odds of suffering frequent falls increasing 69% with each SD increase in CSRT (OR = 1.69, 95% CI: 1.27-2.26, p = falls in people with MS. This test may prove useful in documenting longitudinal changes in fall risk in relation to MS disease progression and effects of interventions. Implications for rehabilitation Good choice stepping reaction time (CSRT) is required for maintaining balance. A simple low-tech CSRT test has excellent discriminative and predictive validity in relation to falls in people with MS. This test may prove useful documenting longitudinal changes in fall risk in relation to MS disease progression and effects of interventions.

  3. Full-course drug challenge test in the diagnosis of delayed allergic reactions to penicillin

    DEFF Research Database (Denmark)

    Borch, Jakob E; Bindslev-Jensen, Carsten

    2011-01-01

    Drug challenge test (DCT) has long been the most sensitive test in the allergological work-up when investigating for penicillin allergy.......Drug challenge test (DCT) has long been the most sensitive test in the allergological work-up when investigating for penicillin allergy....

  4. Software approach to automatic patching of analog computer

    Science.gov (United States)

    1973-01-01

    The Automatic Patching Verification program (APV) is described which provides the hybrid computer programmer with a convenient method of performing a static check of the analog portion of his study. The static check insures that the program is patched as specified, and that the computing components being used are operating correctly. The APV language the programmer uses to specify his conditions and interconnections is similar to the FORTRAN language in syntax. The APV control program reads APV source program statements from an assigned input device. Each source program statement is processed immediately after it is read. A statement may select an analog console, set an analog mode, set a potentiometer or DAC, or read from the analog console and perform a test. Statements are read and processed sequentially. If an error condition is detected, an output occurs on an assigned output device. When an end statement is read, the test is terminated.

  5. Testing of a Liquid Oxygen/Liquid Methane Reaction Control Thruster in a New Altitude Rocket Engine Test Facility

    Science.gov (United States)

    Meyer, Michael L.; Arrington, Lynn A.; Kleinhenz, Julie E.; Marshall, William M.

    2012-01-01

    A relocated rocket engine test facility, the Altitude Combustion Stand (ACS), was activated in 2009 at the NASA Glenn Research Center. This facility has the capability to test with a variety of propellants and up to a thrust level of 2000 lbf (8.9 kN) with precise measurement of propellant conditions, propellant flow rates, thrust and altitude conditions. These measurements enable accurate determination of a thruster and/or nozzle s altitude performance for both technology development and flight qualification purposes. In addition the facility was designed to enable efficient test operations to control costs for technology and advanced development projects. A liquid oxygen-liquid methane technology development test program was conducted in the ACS from the fall of 2009 to the fall of 2010. Three test phases were conducted investigating different operational modes and in addition, the project required the complexity of controlling propellant inlet temperatures over an extremely wide range. Despite the challenges of a unique propellant (liquid methane) and wide operating conditions, the facility performed well and delivered up to 24 hot fire tests in a single test day. The resulting data validated the feasibility of utilizing this propellant combination for future deep space applications.

  6. A Small-Scale Capsule Test for Investigating the Sodium-Carbon Dioxide Reaction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B. H.; Choi, J. H.; Suk, S. D.; Kim, J. M.; Choi, B. H.; Kim, B. H.; Hahn, D. H

    2007-01-15

    The utilization of modular sodium-to-supercritical CO{sub 2} heat exchangers may yield significant improvements for an overall plant energy utilization. The consequences of a failure of the sodium CO{sub 2} heat exchanger boundary, however, would involve the blowdown and intermixing of high-pressure CO{sub 2} in a sodium pool, causing a pressurization which may threaten the structural integrity of the heat exchanger. Available data seems to indicate that the chemical reaction between sodium and CO{sub 2} would likely produce sodium oxides, sodium carbonate, carbon and carbon monoxide. Information on the kinetics of the sodium-CO{sub 2} reaction is virtually non-existent.

  7. The impact of meningococcal polymerase chain reaction testing on laboratory confirmation of invasive meningococcal disease.

    LENUS (Irish Health Repository)

    Drew, Richard J

    2012-03-01

    Laboratory methods of diagnosis were examined for 266 children with invasive meningococcal disease. Seventy-five (36%) of 207 cases with bloodstream infection had both positive blood culture and blood meningococcal polymerase chain reaction (PCR), 130 (63%) negative blood culture and positive blood PCR, and 2 (1%) had positive blood culture and negative blood PCR. Sixty-three percent of cases were diagnosed by PCR alone.

  8. Utility of a rapid immunochromatographic strip test in detecting canine parvovirus infection compared with polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    Sundaran S. Tinky

    2015-04-01

    Full Text Available Aim: The present study was undertaken to detect the presence of canine parvovirus (CPV in fecal samples of diarrheic dogs by conventional polymerase chain reaction (PCR and immunochromatographic (IC strip test and to compare the diagnostic potential of these tests. Materials and Methods: A total of 50 fecal samples collected from diarrheic dogs suspected for CPV infection were subjected to PCR using CPV-555 primer amplifying the gene coding for the VP1 protein. These samples were also tested by IC strip test using a commercial rapid Ag test kit. The results were statistically analyzed using McNemar test. Results: A total of 22 samples (44% were detected as positive by PCR, which yielded a specific amplicon of 583 bp. In IC strip test, 18 (36% samples were found to be positive. The sensitivity of the test as compared to PCR was found to be 72.22% and specificity was 92.86%. Positive predictive value and negative predictive value of IC strip test was found to be 88.89% and 81.25%, respectively. Statistical analysis of the results of PCR and IC assay using McNemar test revealed no significant difference (p>0.05. Conclusion: The IC strip test could be employed as a rapid field level diagnostic tool for the diagnosis of canine parvoviral diarrhea.

  9. Assessing the accuracy of a polymerase chain reaction test for Ichthyophonus hoferi in Yukon River Chinook salmon Oncorhynchus tshawytscha.

    Science.gov (United States)

    Whipps, Christopher M; Burton, Tamara; Watral, Virginia G; St-Hilaire, Sophie; Kent, Michael L

    2006-01-30

    Ichthyophonus hoferi Plehn & Mulsow, 1911, is a cosmopolitan, protistan pathogen of marine fishes. It is prevalent in mature returning Chinook salmon Oncorhynchus tshawytscha in the Yukon River watershed, and may be associated with prespawning mortality. We developed and evaluated a polymerase chain reaction (PCR) test for I. hoferi using primers specific to the parasite's small subunit rDNA. The test has a minimum detection limit of approximately 10(-5) parasite spores per reaction and does not cross-react with the closely related salmon parasites Dermocystidium salmonis or Sphaerothecum destruens. Sensitivity and specificity of the PCR test used on somatic muscle and heart tissue for detecting infected fish were determined using 334 Chinook salmon collected from the Yukon River at 2 locations (Tanana and Emmonak) in 2003 and 2004. The true infection status of the fish was determined by testing somatic muscle, heart and kidney tissue using histological evaluation, culture, and PCR. The severity of infection was grouped into 2 categories, light and heavy infection. The probability of detecting a heavily infected fish (sensitivity of the test) was generally much higher than the probability of detecting light infection, suggesting that more than one tissue and/or method should be used to accurately detect light or early infection by I. hoferi. The probability of correctly identifying a negative fish (specificity of the test) was always greater than 94% regardless of the tissue used, infection severity, sampling site or year of collection.

  10. Quick-Reaction Report on Wastewater Testing at the Marine Corps Combat Development Command, Quantico, Virginia

    National Research Council Canada - National Science Library

    Granetto, Paul

    1996-01-01

    .... Specifically, we determined which of the following was more cost-effective for the Command: to perform wastewater testing at the Mainside wastewater treatment plant laboratory or to have the testing done by contract...

  11. Clinical study of a retinoic acid-loaded microneedle patch for seborrheic keratosis or senile lentigo.

    Science.gov (United States)

    Hirobe, Sachiko; Otsuka, Risa; Iioka, Hiroshi; Quan, Ying-Shu; Kamiyama, Fumio; Asada, Hideo; Okada, Naoki; Nakagawa, Shinsaku

    2017-01-01

    Pigmented lesions such as of seborrheic keratosis and senile lentigo, which are commonly seen on skin of people>50years of age, are considered unattractive and disfiguring because of their negative psychological impact. Drug therapy using all-trans retinoic acid (ATRA) is an attractive option for self-treatment at home. We have developed an ATRA-loaded microneedle patch (ATRA-MN) and confirmed the pharmacological effects of ATRA-MN application in mice. Here, we describe a clinical study to evaluate the safety and efficacy of ATRA-MN in subjects with seborrheic keratosis or senile lentigo. ATRA-MN was applied to the lesion site of each subject for 6h once per week for 4weeks. The skin irritation reaction was scored to assess adverse reactions and blood tests were performed to evaluate the presence of systemic adverse reactions. To assess the treatment effect using ATRA-MN, the desquamation and whitening ability of the investigational skin was observed. Desquamation of the stratum corneum was observed following four ATRA-MN applications at 1-week intervals, but ATRA-MN applications did not induce severe local or systemic adverse effects. These results showed that ATRA-MN treatment is promising as a safe and effective therapy for seborrheic keratosis and senile lentigo. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Smooth surfaces from rational bilinear patches

    KAUST Repository

    Shi, Ling; Wang, Jun; Pottmann, Helmut

    2014-01-01

    Smooth freeform skins from simple panels constitute a challenging topic arising in contemporary architecture. We contribute to this problem area by showing how to approximate a negatively curved surface by smoothly joined rational bilinear patches

  13. Task assignment No. 3. Solar audience test summary report. [Reactions of viewers to public service advertisements about solar energy

    Energy Technology Data Exchange (ETDEWEB)

    1980-12-03

    Audience response to a public service advertisement concerning solar energy was tested. The test was designed to answer four categories of questions: (1) what information on solar energy in general is conveyed by the advertisement. What additional information is desired; (2) what is the reaction of the respondent to specific components or characteristics of the advertisment; (3) how appropriate is the use of the American Indian in conveying the message; and (4) how likely is the respondent to take further action as a result of viewing the advertisment. The rationale and methods for answering each question are discussed. (LEW)

  14. Simulation experiments for a large leak sodium-water reaction analysis. Volume 4. IHTS/relief system simulation tests

    International Nuclear Information System (INIS)

    Ploeger, D.W.

    1978-09-01

    Tests were performed in which a simplified 1/8-scale model of the intermediate heat transfer system and relief system of a LMFBR was subjected to a simulated sodium-water reaction in a steam generator. Pressures in the intermediate heat exchanger (IHX) and in the pipe were measured. The flow of water through the relief system was photographed and its velocity was measured. The forces on the relief system elbows resulting from the fluid flow were also measured. The tests were performed primarily to validate pulse propagation codes used for design and for direct use as design data

  15. The effects of patch shape and connectivity on nest site selection and reproductive success of the Indigo Bunting.

    Energy Technology Data Exchange (ETDEWEB)

    Weldon, Aimee Jean

    2004-07-01

    Description – Ph.D Dissertation. North Carolina State University. Raleigh, North Carolina. 135 pp. Abatract - Habitat fragmentation and its associated effects have been blamed for the recent population declines of many Neotropical migratory bird species. Increased predation and parasitism resulting from edge-related effects have been implicated for poor nesting success in many studies, mostly of forest interior species. However, little attention has been devoted to disturbance-dependent birds. In this study, I examine how patch shape and connectivity in fragmented landscapes affects the reproductive success of disturbance-dependent bird species, specifically the Indigo Bunting (Passerina cyanea). I conducted my study in a landscape-scale experimental system of similar-area habitat patches that differed in connectivity and in shape. Shapes differed between edgy and rectangular forms, where edgy patches contained 50% more edge than rectangular patches. I tested whether edgy patches function as ecological traps for species with strong edge preferences, by leading them to select dangerous habitats. Indigo Buntings preferentially selected edgy patches over rectangular patches, but experienced significantly lower reproductive success in edgy patches early in the season. Although predation pressure intensified in rectangular patches late in the season, seasonal fecundity was still significantly lower in edgy patches, providing the first empirical evidence that edges can function as ecological traps for Indigo Buntings. A second objective of my study was to evaluate the efficacy of conservation corridors for disturbance-dependent bird species. Conservation corridors have become a popular strategy to preserve biodiversity and promote gene flow in fragmented landscapes, but corridors may also have negative consequences. I tested the hypothesis that corridors can increase nest predation risk in connected patches relative to unconnected patches. Nest predation rates

  16. Monitoring coping style moderates emotional reactions to genetic testing for hereditary nonpolyposis colorectal cancer: a longitudinal study.

    Science.gov (United States)

    Shiloh, S; Koehly, L; Jenkins, J; Martin, J; Hadley, D

    2008-08-01

    The emotional effects of genetic testing for hereditary nonpolyposis colorectal cancer (HNPCC) provided within a counseling program were assessed among 253 individuals. Assessments were scheduled at baseline before testing, and again after 6 and 12 months post-test. Negative emotional reactions were evaluated using the Revised Impact of Event Scale and the Center for Epidemiological Studies-Depression Scale. Monitoring coping style was assessed at baseline using the Miller Behavioral Style Scale. Mean reductions were indicated in distress and depression levels within the first 6 months after counseling and testing. High monitors were generally more distressed than low monitors, specifically if they had indeterminate or positive results. Genetic counseling and testing for HNPCC do not result in long-term distress for most people. Of the variables investigated, only time and coping style have main effects on emotional reactions, and the impacts of mutation status are moderated by coping style. Psychological interventions, aimed to alleviate adverse emotional effects, were suggested for certain participants, i.e. recipients of positive or indeterminate results who are high monitors.

  17. Hot-Fire Testing of 100 LB(sub F) LOX/LCH4 Reaction Control Engine at Altitude Conditions

    Science.gov (United States)

    Marshall, William M.; Kleinhenz, Julie E.

    2010-01-01

    Liquid oxygen/liquid methane (LO2/LCH4 ) has recently been viewed as a potential green propulsion system for both the Altair ascent main engine (AME) and reaction control system (RCS). The Propulsion and Cryogenic Advanced Development Project (PCAD) has been tasked by NASA to develop these green propellant systems to enable safe and cost effective exploration missions. However, experience with LO2/LCH4 as a propellant combination is limited, so testing of these systems is critical to demonstrating reliable ignition and performance. A test program of a 100 lb f reaction control engine (RCE) is underway at the Altitude Combustion Stand (ACS) of the NASA Glenn Research Center, with a focus on conducting tests at altitude conditions. These tests include a unique propellant conditioning feed system (PCFS) which allows for the inlet conditions of the propellant to be varied to test warm to subcooled liquid propellant temperatures. Engine performance, including thrust, c* and vacuum specific impulse (I(sub sp,vac)) will be presented as a function of propellant temperature conditions. In general, the engine performed as expected, with higher performance at warmer propellant temperatures but better efficiency at lower propellant temperatures. Mixture ratio effects were inconclusive within the uncertainty bands of data, but qualitatively showed higher performance at lower ratios.

  18. The Exchange Reaction Between Methane Hydrate and Carbon Dioxide: An Oceanic Feasibility Test

    Science.gov (United States)

    Dunk, R. M.; Brewer, P. G.; Peltzer, E. T.; Walz, P. M.; Hester, K. C.; Sloan, E. D.

    2006-12-01

    The conversion of CH4 hydrate to CO2 hydrate offers, in principle, a way of sequestering CO2, with the additional recovery of CH4 gas as an energy source. We report results from the first in-situ oceanic experiment on this reaction, carried out in August 2006 at the massive thermogenic hydrate mounds in 850 m water depth, Barkley Canyon, offshore from Vancouver Island (48° 18.642' N, 126° 3.903' W), using MBARI's ROV Tiburon deployed from the R/V Western Flyer. Two small cores (10 cm length, 4 cm diameter) of white hydrate were collected from exposed outcrops using an ROV operated tool and hydraulically ejected into a glass walled, closed top, reaction chamber. Approximately 2 L of liquid CO2 were dispensed into the chamber, and the chamber transferred to an aluminium base plate to seal the system. Under ambient conditions (P = 870 dbar, T = 4.0 °C, S = 34.2), the densities of natural gas hydrate and liquid CO2 are closely matched and less than that of seawater, where the hydrate cores floated at the top of the chamber fully immersed within the buoyant liquid CO2. Over the following ~48 hours, the system was inspected periodically with the ROV HDTV camera prior to examination with the sea-going laser Raman spectrometer, DORISS II. For this, the chamber was transferred to a Precision Underwater Positioner (PUP) that enabled focusing of the laser beam with sub- mm precision. Our choice of where to focus the laser was based upon the need to explore all phases the cored natural gas hydrate, liquid CO2, any created CO2 hydrate, and any liberated CH4 gas. The natural gas hydrate was composed primarily of CH4, with minor amounts of C2H6 and C3H8, indicating the presence of Structure II hydrate. To date, laboratory experiments have focused on the reaction between pure Structure I CH4 hydrate and CO2 vapour, where the difference in free energy between the CH4 and CO2 hydrate states provides a thermodynamic argument in favour of conversion. However for a Structure II

  19. Preparation and characterization of gellan gum/glucosamine/clioquinol film as oral cancer treatment patch.

    Science.gov (United States)

    Tsai, Wanchi; Tsai, Huifang; Wong, Yinuan; Hong, Juiyen; Chang, Shwujen; Lee, Mingwei

    2018-01-01

    To administer cancer drugs with improved convenience to patients and to enhance the bioavailability of cancer drugs for oral cancer therapy, this study prepared gellan gum/glucosamine/clioquinol (GG/GS/CQ) film as the oral cancer treatment patch. GG/GS/CQ film fabricated through the EDC-mediated coupling reactions (GG/GS/CQ/EDC film). The film of the physicochemical properties and drug release kinetics were studied. The effectiveness of GG/GS/CQ/EDC film as oral cancer treatment patch were evaluated with the animal model. The results confirmed that CQ can be incorporated via EDC-mediated covalent conjugation to gellan gum/glucosamine. Mechanical testing revealed that the maximum tensile strength and elongation percentage at break were 1.91kgf/mm 2 and 5.01% for GG/GS/CQ/EDC film. After a drug release experiment lasting 45days, 86.8% of CQ was released from GG/GS/CQ/EDC film. The Huguchi model fit the GG/GS/CQ/EDC drug release data with high correlation coefficients (R 2 =0.9994, respectively). The effect of the CQ dose on oral cancer cells (OC-2) was tested, and the IC 50 of CQ alone and CQ with 10μM CuCl 2 were 9.59 and 2.22μM, respectively. The animal testing indicated that GG/GS/CQ/EDC film was decreased epidermal growth factor receptor (EGFR) expression and suppress tumor progression. These findings provide insights into a possible use for GG/GS/CQ/EDC film for oral ca in clinical practice. The GG/GS/CQ/EDC film is suitable as the dressing for use in the treatment of early-stage cancer or as wound care after surgery in late-stage of oral cancer treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Experimental tests of recent nuclear models with the (n,γ) reaction

    International Nuclear Information System (INIS)

    Casten, R.F.

    1978-01-01

    The nonselectivity of the (n,γ) reaction provides a powerful tool for the study of those nuclear models of broad applicability whose characteristic excitations span a wide range of degrees of freedom. Several recent examples of this are discussed with particular emphasis on the recent discovery of the 0(6) limit of the interacting boson model and of a new interpretation of the Pt--0s transition region which consequently emerges. Other topics considered include recent extensions of the Nilsson model to new regions of nucleus, excitation energy and complexity of states. 43 references

  1. Analyzing the Safeguarding Our Communities Act: Patch for Patch Return Policy in Ontario

    Directory of Open Access Journals (Sweden)

    Soo-Min Kim

    2018-04-01

    Full Text Available Fentanyl is prescribed to patients suffering from severe chronic pain. Transdermal patches are the best mode of delivery for patients who have developed tolerance for opioids. However, used patches still contain fentanyl that can be extracted and misused, with potentially severe consequences. To address this issue, patients who are prescribed fentanyl patches in Ontario are now required to return previously dispensed patches to receive new patches under the Safeguarding Our Communities Act: Patch for Patch (P4P Return Policy. The problem is significant in Ontario because the province has the largest annual dispense rate of high-dose prescription fentanyl (112 units per 1,000 population in Canada even though the prevalence rate of chronic pain is lower than the national reported range (16.6% in Ontario versus 19.6 to 21.9% in other provinces, according to Gomes et al. 2014. The primary goal of this reform is to instill responsible use of fentanyl patches, and to improve safety for patients and the public by having a central disposal process. The reform was modeled after a community initiative that was pioneered in North Bay after receiving great support from health professional colleges and communities that voluntarily integrated the program prior to the introduction of Bill 33. Preliminary data suggest that the P4P policy is positively received by health professionals, although ongoing evaluation is needed to assess the effectiveness of the policy in reducing misuse and abuse of prescribed fentanyl patches.

  2. Stability of puppy reaction to traditional puppy aptitude test under experimentally reared condtions

    OpenAIRE

    Ishikawa, Keisuke; Eguchi, Yusuke; Uetake, Katsuji; Tnaka, Toshio

    2010-01-01

    The puppy aptitude test (PAT) is a general method for choosing a puppy. However, the reliability of the test has been in doubt because of its lack of a scientific base. In this report, we conducted PAT and some other behavioral tests before and after the establishment of socialization in order to investigate the stability of behavioral traits of puppies. Ten puppies were tested of eleven items on PAT at 57 and 140 days of age. The puppy’s behavior was videotaped and rated by four people using...

  3. Precise tests for the unitarized pion photoproduction impulse amplitude in exclusive nuclear reactions

    International Nuclear Information System (INIS)

    Wittman, R.

    1986-07-01

    An impulse amplitude for pion photoproduction, suitable for the nuclear problem, is constructed with improved background dynamics and unitarity. The superior features of the amplitude are demonstrated at energies between threshold (E/sub γ/ = 150 MeV) and the Δ(1232) resonance energy (E/sub γ/ = 320 MeV) by discussing their effects on partial cross sections relevant to exclusive transitions in the 1p-shell. The specific reactions of 13 C(γ,π - ) 13 N/sub g.s./ and 14 N(γ,π + ) 14 C/sub g.s./ are discussed in light of these more general partial cross sections. The nuclear structure of the A = 14 system helps to enhance the effects considered. At or near resonance, very sizable (20 to 30%) effects arise both from the unitarity and from the refined treatment of the pionic final state interaction generated in the Δ-hole approach. Other examples of charged pion photoproduction reactions for 1p-shell nuclei are discussed briefly. Future theoretical improvements and experimental possibilities are suggested. 61 refs., 58 figs

  4. Analytical electron microscopy examination of solid reaction products in long-term test of SRL 200 waste glasses

    International Nuclear Information System (INIS)

    Buck, E.C.; Fortner, J.A.; Bates, J.K.; Feng, X.; Dietz, N.L.; Bradley, C.R.; Tani, B.S.

    1993-01-01

    Alteration phases, found on the leached surfaces and present as colloids in the leachates of 200-based frit (fully active and simulated) nuclear waste glass, reacted under static test conditions, at a surface area to leachate volume ratio of 20,000 m -1 for 15 days to 728 days, have been examined by analytical electron microscopy. The compositions of the secondary phases were determined using x-ray energy dispersive spectroscopy and electron energy loss spectroscopy, and structural analysis was accomplished by electron diffraction. Long-term samples of simulated glass, which had undergone an acceleration of reaction after 182 days, possessed a number of silicate secondary phases, including; smectite (iron silicate and potassium iron alumina-silicate, weeksite (uranium silicate), zeolite (calcium potassium alumino-silicate), tobermorite (calcium silicate), and a pure silica phase. However, uranium silicates and smectite have also been observed in tests, which have not undergone the acceleration of reaction, in both the leachate and leached layer, suggesting that these phases are not responsible for the acceleration of reaction

  5. The Carbonation of Wollastonite: A Model Reaction to Test Natural and Biomimetic Catalysts for Enhanced CO2 Sequestration

    Directory of Open Access Journals (Sweden)

    Fulvio Di Lorenzo

    2018-05-01

    Full Text Available One of the most promising strategies for the safe and permanent disposal of anthropogenic CO2 is its conversion into carbonate minerals via the carbonation of calcium and magnesium silicates. However, the mechanism of such a reaction is not well constrained, and its slow kinetics is a handicap for the implementation of silicate mineral carbonation as an effective method for CO2 capture and storage (CCS. Here, we studied the different steps of wollastonite (CaSiO3 carbonation (silicate dissolution → carbonate precipitation as a model CCS system for the screening of natural and biomimetic catalysts for this reaction. Tested catalysts included carbonic anhydrase (CA, a natural enzyme that catalyzes the reversible hydration of CO2(aq, and biomimetic metal-organic frameworks (MOFs. Our results show that dissolution is the rate-limiting step for wollastonite carbonation. The overall reaction progresses anisotropically along different [hkl] directions via a pseudomorphic interface-coupled dissolution–precipitation mechanism, leading to partial passivation via secondary surface precipitation of amorphous silica and calcite, which in both cases is anisotropic (i.e., (hkl-specific. CA accelerates the final carbonate precipitation step but hinders the overall carbonation of wollastonite. Remarkably, one of the tested Zr-based MOFs accelerates the dissolution of the silicate. The use of MOFs for enhanced silicate dissolution alone or in combination with other natural or biomimetic catalysts for accelerated carbonation could represent a potentially effective strategy for enhanced mineral CCS.

  6. Reader reaction on the generalized Kruskal-Wallis test for genetic association studies incorporating group uncertainty.

    Science.gov (United States)

    Wu, Baolin; Guan, Weihua

    2015-06-01

    Acar and Sun (2013, Biometrics 69, 427-435) presented a generalized Kruskal-Wallis (GKW) test for genetic association studies that incorporated the genotype uncertainty and showed its robust and competitive performance compared to existing methods. We present another interesting way to derive the GKW test via a rank linear model. © 2014, The International Biometric Society.

  7. Reader Reaction On the generalized Kruskal-Wallis test for genetic association studies incorporating group uncertainty

    OpenAIRE

    Wu, Baolin; Guan, Weihua

    2014-01-01

    Acar and Sun (2013, Biometrics, 69, 427-435) presented a generalized Kruskal-Wallis (GKW) test for genetic association studies that incorporated the genotype uncertainty and showed its robust and competitive performance compared to existing methods. We present another interesting way to derive the GKW test via a rank linear model.

  8. The predatory mite Phytoseiulus persimilis adjusts patch-leaving to own and progeny prey needs.

    Science.gov (United States)

    Vanas, V; Enigl, M; Walzer, A; Schausberger, P

    2006-01-01

    Integration of optimal foraging and optimal oviposition theories suggests that predator females should adjust patch leaving to own and progeny prey needs to maximize current and future reproductive success. We tested this hypothesis in the predatory mite Phytoseiulus persimilis and its patchily distributed prey, the two-spotted spider mite Tetranychus urticae. In three separate experiments we assessed (1) the minimum number of prey needed to complete juvenile development, (2) the minimum number of prey needed to produce an egg, and (3) the ratio between eggs laid and spider mites left when a gravid P. persimilis female leaves a patch. Experiments (1) and (2) were the pre-requirements to assess the fitness costs associated with staying or leaving a prey patch. Immature P. persimilis needed at least 7 and on average 14+/-3.6 (SD) T. urticae eggs to reach adulthood. Gravid females needed at least 5 and on average 8.5+/-3.1 (SD) T. urticae eggs to produce an egg. Most females left the initial patch before spider mite extinction, leaving prey for progeny to develop to adulthood. Females placed in a low density patch left 5.6+/-6.1 (SD) eggs per egg laid, whereas those placed in a high density patch left 15.8+/-13.7 (SD) eggs per egg laid. The three experiments in concert suggest that gravid P. persimilis females are able to balance the trade off between optimal foraging and optimal oviposition and adjust patch-leaving to own and progeny prey needs.

  9. Effects of a calm companion on fear reactions in naive test horses

    DEFF Research Database (Denmark)

    Christensen, Janne Winther; Malmkvist, Jens; Nielsen, Birte Lindstrøm

    2008-01-01

    : Minimally handled (n = 36), 2-year-old stallions were used, 18 as subjects and 18 as companions. Companion horses (n = 9) were habituated to an otherwise frightening, standardised test stimulus (calm companions), whereas the rest (n = 9) of the companion horses remained nonhabituated (control companions......). During the test, unique pairs of companion and subject horses were exposed to the test stimulus while heart rate and behavioural responses were registered. Subsequently, subject horses were exposed to the stimulus on their own (post test). Results: Subject horses, paired with a calm companion horse......, showed less fear-related behaviour and lower heart rate responses compared to subject horses with control companions. Results from the post test suggest that the difference between treatment groups remained in the subsequent absence of companion horses. Conclusions and potential relevance: It appears...

  10. Charge-exchange and fusion reaction measurements during compression experiments with neutral beam heating in the Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    Kaita, R.; Heidbrink, W.W.; Hammett, G.W.

    1986-04-01

    Adiabatic toroidal compression experiments were performed in conjunction with high power neutral beam injection in the Tokamak Fusion Test Reactor (TFTR). Acceleration of beam ions to energies nearly twice the injection energy was measured with a charge-exchange neutral particle analyzer. Measurements were also made of 2.5 MeV neutrons and 15 MeV protons produced in fusion reactions between the deuterium beam ions and the thermal deuterium and 3 He ions, respectively. When the plasma was compressed, the d(d,n) 3 He fusion reaction rate increased a factor of five, and the 3 He(d,p) 4 He rate by a factor of twenty. These data were simulated with a bounce-averaged Fokker-Planck program, which assumed conservation of angular momentum and magnetic moment during compression. The results indicate that the beam ion acceleration was consistent with adiabatic scaling

  11. An Angiotensin II type 1 receptor activation switch patch revealed through Evolutionary Trace analysis

    DEFF Research Database (Denmark)

    Bonde, Marie Mi; Yao, Rong; Ma, Jian-Nong

    2010-01-01

    to be completely resolved. Evolutionary Trace (ET) analysis is a computational method, which identifies clusters of functionally important residues by integrating information on evolutionary important residue variations with receptor structure. Combined with known mutational data, ET predicted a patch of residues......) displayed phenotypes associated with changed activation state, such as increased agonist affinity or basal activity, promiscuous activation, or constitutive internalization highlighting the importance of testing different signaling pathways. We conclude that this evolutionary important patch mediates...

  12. Experimental investigation of solid sodium-water reaction: tests results and phenomenological analysis

    International Nuclear Information System (INIS)

    Daudin, K.; Beauchamp, F.; Proust, C.

    2014-01-01

    Sodium-Water Reaction (SWR) is an issue one has to be capable to deal with for the next generation of nuclear reactors (SFR for GEN IV). The background of these experiments is the improvement of safety demonstration regarding SWR in an open volume. This experimental campaign is conducted at the CEA Cadarache inside a cylindrical reactor filled with inert gas. The sodium is inside a loading pot and water comes into contact by immersion. SWR and its physical effects are followed by different pressure and temperature sensors. The results show a limit to the overpressure increasing sodium mass. Global assessment of physical effects of SWR contributes to put forward the relative nature of phenomena with geometric configuration, and the importance of scale effects. (authors)

  13. Testing two-nucleon transfer reaction mechanism with elementary modes of excitation in exotic nuclei

    CERN Document Server

    Broglia, R A; Idini, A; Barranco, F; Vigezzi, E

    2015-01-01

    Nuclear Field Theory of structure and reactions is confronted with observations made on neutron halo dripline nuclei, resulting in the prediction of a novel (symbiotic) mode of nuclear excitation, and on the observation of the virtual effect of the halo phenomenon in the apparently non-halo nucleus $^7$Li. This effect is forced to become real by intervening the virtual process with an external (t,p) field which, combined with accurate predictive abilities concerning the absolute differential cross section, reveals an increase of a factor 2 in the cross section due to the presence of halo ground state correlations, and is essential to reproduce the value of the observed $d \\sigma(^7$Li(t,p)$^9$Li)/d$\\Omega$.

  14. Coevolution of patch-type dependent emigration and patch-type dependent immigration.

    Science.gov (United States)

    Weigang, Helene C

    2017-08-07

    The three phases of dispersal - emigration, transfer and immigration - are affecting each other and the former and latter decisions may depend on patch types. Despite the inevitable fact of the complexity of the dispersal process, patch-type dependencies of dispersal decisions modelled as emigration and immigration are usually missing in theoretical dispersal models. Here, I investigate the coevolution of patch-type dependent emigration and patch-type dependent immigration in an extended Hamilton-May model. The dispersing population inhabits a landscape structured into many patches of two types and disperses during a continuous-time season. The trait under consideration is a four dimensional vector consisting of two values for emigration probability from the patches and two values for immigration probability into the patches of each type. Using the adaptive dynamics approach I show that four qualitatively different dispersal strategies may evolve in different parameter regions, including a counterintuitive strategy, where patches of one type are fully dispersed from (emigration probability is one) but individuals nevertheless always immigrate into them during the dispersal season (immigration probability is one). I present examples of evolutionary branching in a wide parameter range, when the patches with high local death rate during the dispersal season guarantee a high expected disperser output. I find that two dispersal strategies can coexist after evolutionary branching: a strategy with full immigration only into the patches with high expected disperser output coexists with a strategy that immigrates into any patch. Stochastic simulations agree with the numerical predictions. Since evolutionary branching is also found when immigration evolves alone, the present study is adding coevolutionary constraints on the emigration traits and hence finds that the coevolution of a higher dimensional trait sometimes hinders evolutionary diversification. Copyright © 2017

  15. Efficacy and safety of a new microneedle patch for skin brightening: A Randomized, split-face, single-blind study.

    Science.gov (United States)

    Park, Kui Young; Kwon, Hyun Jung; Lee, Changjin; Kim, Daegun; Yoon, Jun Jin; Kim, Myeong Nam; Kim, Beom Joon

    2017-09-01

    Although microneedles are one of the best transdermal drug delivery systems for active compounds, few clinical trials have examined the safety and efficacy of brightening microneedle patches. To determine the efficacy and safety of a newly developed whitening microneedle patch. A split-face study was designed for efficacy assessment with 34 Korean women applying the tested product (a whitening microneedle patch) on one cheek and a control whitening essence on the other. We objectively measured changes in melanin index values and skin brightness by mexameter and chromameter. Each participant also used global assessment to determine skin whitening. In addition, 55 participants were selected for primary skin irritation tests and repeated insult patch tests for safety assessments. Mean skin brightness and melanin indexes improved (Pmicroneedle patch was effective and safe for skin brightening and would be a promising functional cosmetic product. © 2017 Wiley Periodicals, Inc.

  16. Methylisothiazolinone testing at 2000 ppm: a prevalent sensitizer for allergic contact dermatitis.

    Science.gov (United States)

    Ham, Kaiya; Posso-De Los Rios, Claudia J; Gooderham, Melinda

    2015-01-01

    Methylchloroisothiazolinone (MCI) and methylisothiazolinone (MI) have been identified as potent allergens. The optimal MI concentration for patch testing for reaction to these agents has not yet been identified, but it has been suggested that testing MI at 2000 ppm may reduce false-negative reactions. The aim of this study was to report allergic reactions to MI and MCI/MI detected in a community dermatology practice setting in Ontario, Canada. The patch test records of patients with suspected allergic contact dermatitis seen between October 2007 and June 2014 were reviewed. We compared positive patch testing before and after December 2011 when a higher MI concentration was used (2000 ppm aqueous) in addition to the baseline series MCI/MI at 100 ppm. A total of 794 patient records were reviewed. There were 38 true-positive reactions to MI or MCI/MI. Of these 38 patients, 26 (68%) were female. We detected an overall increase in the rate of positive patch testing to MCI/MI, MI alone, or both from 3.13% to 7.45% when MI concentration was introduced at 2000 ppm aqueous. Occupational differences existed between sexes. The addition of MI at 2000 ppm to our screening series effectively increased the detection of MI-induced allergic contact dermatitis.

  17. Detection of the pyrogen in the radiopharmaceuticals using Limulus test and inhibitory factors in the gelation reaction

    International Nuclear Information System (INIS)

    Murata, Hajime; Iio, Masahiro; Yamada, Hideo; Chiba, Kazuo; Kobayashi, Masayoshi.

    1975-01-01

    To examine the sensitivities of the Limulus test and the inhibitory factors in radiopharmaceuticals, the following procedures were employed. Twenty commonly used radiopharmaceuticals were examined by Limulus Lysate (Pre-gel). In order to detect the inhibitory factors, several doses of endotoxin (E. coli) were added to the radiopharmaceuticals before the Limulus test was made and the results were compared with control results using saline solution of endotoxin. When the pH of the reaction solution lay out of a suitable range (6.0-7.5), the pH was adjusted by Tris-HCl buffer before the reaction. The sensitivity of the Limulus test control using Pre-gel was positive at a concentration of 10 -3 μg/ml of endotoxin. The Limulus test was sensitive and without inhibitory reactions for sup(99m)TcO 4 -, sup(99m)Tc-albumin, sup(99m)Tc-MAA, sup(99m)Tc-Sn-colloid, 131 I-hippurate, Na 131 I, Na 2 51 CrO 4 , 67 Ga-citrate and 57 Co-bleomycin as they were supplied. 111 In-DTPA, sup(99m)Tc-phytate, sup(99m)Tc-pyrophosphate, sup(99m)Tc-DTPA, 131 I-PVP, 59 FeCl 3 , Na-phosphate ( 32 P), 198 Au-colloid and 75 Se-selenomethionine needed to have their pH adjusted to avoid inhibition. Benzyl alcohol in the radiopharmaceutical showed an inhibitory effect at a concentration greater than 1%. Commonly used 169 Yb-DTPA which was evaluated by this test had a sensitivity of 2.5 x 10 -3 μg/ml due to addition of a small amount of benzyl alcohol. 131 I-BSP showed intense inhibition in gelation reaction. Contaminations of endotoxin were detected in sup(99m)Tc-albumin, sup(99m)Tc-Sn-colloid, 131 I-hippurate, Na 131 I, Na 2 51 CrO 4 , 198 Au-colloid, 57 Co-bleomycin and 75 Se-selenomethionine. (auth.)

  18. Detection of the pyrogen in the radiopharmaceuticals using Limulus test and inhibitory factors in the gelation reaction

    Energy Technology Data Exchange (ETDEWEB)

    Murata, H; Iio, M; Yamada, H; Chiba, K [Tokyo Metropolitan Geriatric Medical Center (Japan); Kobayashi, M

    1975-08-01

    To examine the sensitivities of the Limulus test and the inhibitory factors in radiopharmaceuticals, the following procedures were employed. Twenty commonly used radiopharmaceuticals were examined by Limulus Lysate (Pre-gel). In order to detect the inhibitory factors, several doses of endotoxin (E. coli) were added to the radiopharmaceuticals before the Limulus test was made and the results were compared with control results using saline solution of endotoxin. When the pH of the reaction solution lay out of a suitable range (6.0-7.5), the pH was adjusted by Tris-HCl buffer before the reaction. The sensitivity of the Limulus test control using Pre-gel was positive at a concentration of 10/sup -3/ ..mu..g/ml of endotoxin. The Limulus test was sensitive and without inhibitory reactions for sup(99m)TcO/sub 4/-, sup(99m)Tc-albumin, sup(99m)Tc-MAA, sup(99m)Tc-Sn-colloid, /sup 131/I-hippurate, Na/sup 131/I, Na/sub 2//sup 51/CrO/sub 4/, /sup 67/Ga-citrate and /sup 57/Co-bleomycin as they were supplied. /sup 111/In-DTPA, sup(99m)Tc-phytate, sup(99m)Tc-pyrophosphate, sup(99m)Tc-DTPA, /sup 131/I-PVP, /sup 59/FeCl/sub 3/, Na-phosphate (/sup 32/P), /sup 198/Au-colloid and /sup 75/Se-selenomethionine needed to have their pH adjusted to avoid inhibition. Benzyl alcohol in the radiopharmaceutical showed an inhibitory effect at a concentration greater than 1%. Commonly used /sup 169/Yb-DTPA which was evaluated by this test had a sensitivity of 2.5 x 10/sup -3/ ..mu..g/ml due to addition of a small amount of benzyl alcohol. /sup 131/I-BSP showed intense inhibition in gelation reaction. Contaminations of endotoxin were detected in sup(99m)Tc-albumin, sup(99m)Tc-Sn-colloid, /sup 131/I-hippurate, Na/sup 131/I, Na/sub 2//sup 51/CrO/sub 4/, /sup 198/Au-colloid, /sup 57/Co-bleomycin and /sup 75/Se-selenomethionine.

  19. PL-PatchSurfer: A Novel Molecular Local Surface-Based Method for Exploring Protein-Ligand Interactions

    Directory of Open Access Journals (Sweden)

    Bingjie Hu

    2014-08-01

    Full Text Available Structure-based computational methods have been widely used in exploring protein-ligand interactions, including predicting the binding ligands of a given protein based on their structural complementarity. Compared to other protein and ligand representations, the advantages of a surface representation include reduced sensitivity to subtle changes in the pocket and ligand conformation and fast search speed. Here we developed a novel method named PL-PatchSurfer (Protein-Ligand PatchSurfer. PL-PatchSurfer represents the protein binding pocket and the ligand molecular surface as a combination of segmented surface patches. Each patch is characterized by its geometrical shape and the electrostatic potential, which are represented using the 3D Zernike descriptor (3DZD. We first tested PL-PatchSurfer on binding ligand prediction and found it outperformed the pocket-similarity based ligand prediction program. We then optimized the search algorithm of PL-PatchSurfer using the PDBbind dataset. Finally, we explored the utility of applying PL-PatchSurfer to a larger and more diverse dataset and showed that PL-PatchSurfer was able to provide a high early enrichment for most of the targets. To the best of our knowledge, PL-PatchSurfer is the first surface patch-based method that treats ligand complementarity at protein binding sites. We believe that using a surface patch approach to better understand protein-ligand interactions has the potential to significantly enhance the design of new ligands for a wide array of drug-targets.

  20. Randomized, double-blind, placebo-controlled trial using lidocaine patch 5% in traumatic rib fractures.

    Science.gov (United States)

    Ingalls, Nichole K; Horton, Zachary A; Bettendorf, Matthew; Frye, Ira; Rodriguez, Carlos

    2010-02-01

    The lidocaine patch 5% was developed to treat postherpetic neuralgia. Anecdotal experience at our institution suggests the lidocaine patch 5% decreases narcotic usage in patients with traumatic rib fractures. This trial was developed to define the patch's efficacy. Patients with rib fractures admitted to the trauma service at our Level I trauma center were enrolled and randomized in a 1 to 1 double-blind manner to receive a lidocaine patch 5% or placebo patch. Fifty-eight patients who met the inclusion criteria were enrolled from January 2007 to August 2008. Demographic and clinical information were recorded. The primary outcomes variable was total narcotic use, analyzed using the 1-tailed Mann-Whitney test. The secondary outcomes variables included non-narcotic pain medication, average pain score, pulmonary complications, and length of stay. Significance was defined based on a 1-sided test for the primary outcome and 2-sided tests for other comparisons, at p rib fractures, gender, trauma mechanism, preinjury lung disease, smoking history, percent of current smokers, and need for placement of chest tube between the lidocaine patch 5% and placebo groups. There was no difference between the lidocaine patch 5% and placebo groups, respectively, with regard to total IV narcotic usage: median, 0.23 units versus 0.26 units; total oral narcotics: median, 4 units versus 7 units; pain score: 5.6 +/- 0.4 versus 6.0 +/- 0.3 (mean +/- SEM); length of stay: 7.8 +/- 1.1 versus 6.2 +/- 0.7; or percentage of patients with pulmonary complications: 72.7% versus 72.0%. The lidocaine patch 5% does not significantly improve pain control in polytrauma patients with traumatic rib fractures.

  1. False-negative reactions to the comparative intradermal tuberculin test for bovine tuberculosis

    Directory of Open Access Journals (Sweden)

    Rudielle A. Rodrigues

    Full Text Available ABSTRACT: According to the Brazilian National Program for the Control and Eradication of Animal Brucellosis and Tuberculosis (PNCEBT, the routine tests for the diagnosis of bovine tuberculosis in the country are the simple intradermal tuberculin test (SITT of the Ministry of Agriculture, Livestock and Food Supply (MAPA, the caudal fold test and the comparative intradermal tuberculin test (CITT. The latter is also used as a confirmatory test. A group of 53 animals from three dairy herds in a focal area for bovine tuberculosis, that were submitted to depopulation in the state of Rio Grande do Sul, were submitted to the CITT. Tissues were cultured and the resulting colonies were confirmed by PCR and DNA sequencing. Among the 53 animals analyzed using the CITT, 32 (60.4% were negative, 14 (26.4% were positive and seven (13.2% results were inconclusive. The CITT detected 11 of the 39 animals with culture-confirmed M. bovis infection as positive. Among the total of 14 uninfected animals based on cultures, the CBT detected eight as negative. Thus, the CITT demonstrated sensitivity of 28.2% and specificity of 57.1% for the population sampled. A total of 24/32 (75.0% of the animals with negative CITT results were culture positive (confirmed by PCR and were considered false negatives based on the CITT. The maintenance of these false-negative animals in herds has serious implications for the control of the disease, since they can be a source of infection. The addition of complementary tests could help identify such animals and increase the odds of diagnostic success.

  2. Diurnal and seasonal occurrence of polar patches

    Directory of Open Access Journals (Sweden)

    A. S. Rodger

    1996-05-01

    Full Text Available Analysis of the diurnal and seasonal variation of polar patches, as identified in two years of HF-radar data from Halley, Antarctica during a period near sunspot maximum, shows that there is a broad maximum in occurrence centred about magnetic noon, not local noon. There are minima in occurrence near midsummer and midwinter, with maxima in occurrence between equinox and winter. There are no significant correlations between the occurrence of polar patches and the corresponding hourly averages of the solar wind and IMF parameters, except that patches usually occur when the interplanetary magnetic field has a southward component. The results can be understood in terms of UT and seasonal differences in the plasma concentration being convected from the dayside ionosphere into the polar cap. In summer and winter the electron concentrations in the polar cap are high and low, respectively, but relatively unstructured. About equinox, a tongue of enhanced ionisation is convected into the polar cap; this tongue is then structured by the effects of the interplanetary magnetic field, but these Halley data cannot be used to separate the various competing mechanisms for patch formation. The observed diurnal and seasonal variation in the occurrence of polar patches are largely consistent with predictions of Sojka et al. (1994 when their results are translated into the southern hemisphere. However, the ionospheric effects of flux transfer events are still considered essential in their formation, a feature not yet included in the Sojka et al. model.

  3. Dermoscopy of shagreen patch: A first report

    Directory of Open Access Journals (Sweden)

    Shivanand Gundalli

    2015-07-01

    Full Text Available The name is derived from French phrase peau chagrinee which is usually found on lower back, buttock and thigh. The major manifestations of Tuberous sclerosis include skin lesions in more than 95%, mental retardation in approximately 50%, autism, seizures in approximately 85%. The incidence at birth is estimated to be 1 in 5800. We report case of shagreen patch in a 27 year female which is present since birth. However there is no history of seizures or consanginous marriage in our case. Associated features are naevus comedonicus and naevus collagenosis, facial angiofibroma. Shagreen patch are present in mandibular area of face. Although, diagnosis is easy, it can be mistaken for inflammatory verrucous epidermal nevus, plaques of other inflammatory skin conditions. Diagnosis is usually on clinical background. Sometimes biopsy is necessary to confirm the diagnosis. Dermoscopy, a non-invasive, in vivo technique for the microscopic examination of pigmented skin lesions, has the potential to improve the diagnostic accuracy. Dermoscopy of Shagreen patch showed reddish-brown strands with white dots giving a cobblestone appearance It can be utilized as a diagnostic aide in the diagnosis of Shagreen patch. Authors evaluated the dermoscopic patterns of Shagreen patch and hence, it is useful in diagnosis.

  4. Microneedle patches for vaccination in developing countries.

    Science.gov (United States)

    Arya, Jaya; Prausnitz, Mark R

    2016-10-28

    Millions of people die of infectious diseases each year, mostly in developing countries, which could largely be prevented by the use of vaccines. While immunization rates have risen since the introduction of the Expanded Program on Immunization (EPI), there remain major challenges to more effective vaccination in developing countries. As a possible solution, microneedle patches containing an array of micron-sized needles on an adhesive backing have been developed to be used for vaccine delivery to the skin. These microneedle patches can be easily and painlessly applied by pressing against the skin and, in some designs, do not leave behind sharps waste. The patches are single-dose, do not require reconstitution, are easy to administer, have reduced size to simplify storage, transportation and waste disposal, and offer the possibility of improved vaccine immunogenicity, dose sparing and thermostability. This review summarizes vaccination challenges in developing countries and discusses advantages that microneedle patches offer for vaccination to address these challenges. We conclude that microneedle patches offer a powerful new technology that can enable more effective vaccination in developing countries. Copyright © 2015. Published by Elsevier B.V.

  5. Expedient construction of small molecule macroarrays via sequential palladium- and copper-mediated reactions and their ex situ biological testing.

    Science.gov (United States)

    Frei, Reto; Breitbach, Anthony S; Blackwell, Helen E

    2012-05-01

    We report the highly efficient syntheses of a series of focused libraries in the small molecule macroarray format using Suzuki-Miyaura and copper-catalyzed azide-alkyne cycloaddition (or "click") reactions. The libraries were based on stilbene and triazole scaffolds, which are known to have a broad range of biological activities, including quorum-sensing (QS) modulation in bacteria. The library products were generated in parallel on the macroarray in extremely short reaction times (~10-20 min) and isolated in excellent purities. Biological testing of one macroarray library post-cleavage (ex situ) revealed several potent agonists of the QS receptor, LuxR, in Vibrio fischeri. These synthetic agonists, in contrast to others that we have reported, were only active in the presence of the native QS signal in V. fischeri, which is suggestive of a different mode of activity. Notably, the results presented herein showcase the ready compatibility of the macroarray platform with chemical reactions that are commonly utilized in small molecule probe and drug discovery today. As such, this work serves to expand the utility of the small molecule macroarray as a rapid and operationally straightforward approach toward the synthesis and screening of bioactive agents.

  6. Prenatal Group B Streptococcus Test Using Real-Time Polymerase Chain Reaction

    Directory of Open Access Journals (Sweden)

    Chi-Feng Wei

    2009-06-01

    Conclusion: It is necessary to perform a GBS test 4 weeks after an initial negative GBS culture at 35–37 weeks of gestation. RT-PCR provides a simple and rapid alternative method for detecting rectovaginal GBS colonization at the time of labor.

  7. The relationship between brain reaction and English reading tests for non-native English speakers.

    Science.gov (United States)

    Cheng, Pei-Wen; Tian, Yu-Jie; Kuo, Ting-Hua; Sun, Koun-Tem

    2016-07-01

    This research analyzed the brain activity of non-native English speakers while engaged in English reading tests. The brain wave event-related potentials (ERPs) of participants were used to analyze the difference between making correct and incorrect choices on English reading test items. Three English reading tests of differing levels were designed and 20 participants, 10 males and 10 females whose ages ranged from 20 to 24, voluntarily participated in the experiment. Experimental results were analyzed by performing independent t-tests on the ERPs of participants for gender, difficulty level, and correct versus wrong options. Participants who chose incorrect options elicited a larger N600, verifying results found in the literature. Another interesting result was found: For incorrectly answered items, different areas of brain showing a significant difference in ERPs between the chosen and non-chosen options corresponded to gender differences; for males, this area was located in the right hemisphere whereas for females, it was located in the left. Experimental results imply that non-native English speaking males and females employ different areas of the brain to comprehend the meaning of difficult items. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Fault-patch stress-transfer efficiency in presence of sub-patch geometric complexity

    KAUST Repository

    Zielke, Olaf

    2015-04-01

    It is well known that faults are not planar surfaces. Instead they exhibit self-similar or self-affine properties that span a wide range of spatial (sub-micrometer to tens-of-kilometer). This geometric fault roughness has a distinct impact on amount and distribution of stresses/strains induced in the medium and on other portions of the fault. However, when numerically simulated (for example in multi-cycle EQ rupture simulations or Coulomb failure stress calculations) this roughness is largely ignored: individual fault patches --the incremental elements that build the fault surface in the respective computer models-- are planar and fault roughness at this and lower spatial scales is not considered. As a result, the fault-patch stress-transfer efficiency may be systematically too large in those numerical simulations with respect to the "actual" efficiency level. Here, we investigate the effect of sub-patch geometric complexity on fault-patch stress-transfer efficiency. For that, we sub-divide a fault patch (e.g., 1x1km) into a large number of sub-patches (e.g., 20x20m) and determine amount of induced stresses at selected positions around that patch for different levels and realizations of fault roughness. For each fault roughness level, we compute mean and standard deviation of the induced stresses, enabling us to compute the coefficient of variation. We normalize those values with stresses from the corresponding single (planar) fault patch, providing scaling factors and their variability for stress transfer efficiency. Given a certain fault roughness that is assumed for a fault, this work provides the means to implement the sub-patch fault roughness into investigations based on fault-patch interaction schemes.

  9. Lateral spread affects nitrogen leaching from urine patches.

    Science.gov (United States)

    Cichota, Rogerio; Vogeler, Iris; Snow, Val; Shepherd, Mark; McAuliffe, Russell; Welten, Brendon

    2018-09-01

    Nitrate leaching from urine deposited by grazing animals is a critical constraint for sustainable dairy farming in New Zealand. While considerable progress has been made to understand the fate of nitrogen (N) under urine patches, little consideration has been given to the spread of urinary N beyond the wetted area. In this study, we modelled the lateral spread of nitrogen from the wetted area of a urine patch to the soil outside the patch using a combination of two process-based models (HYDRUS and APSIM). The simulations provided insights on the extent and temporal pattern for the redistribution of N in the soil following a urine deposition and enabled investigating the effect of lateral spread of urinary N on plant growth and N leaching. The APSIM simulation, using an implementation of a dispersion-diffusion function, was tested against experimental data from a field experiment conducted in spring on a well-drained soil. Depending on the geometry considered for the dispersion-diffusion function (plate or cylindrical) the area-averaged N leaching decreased by 8 and 37% compared with simulations without lateral N spread; this was due to additional N uptake from pasture on the edge area. A sensitivity analysis showed that area-averaged pasture growth was not greatly affected by the value of the dispersion factor used in the model, whereas N leaching was very sensitive. Thus, the need to account for the edge effect may depend on the objective of the simulations. The modelling results also showed that considering lateral spread of urinary N was sufficient to describe the experimental data, but plant root uptake across urine patch zones may still be relevant in other conditions. Although further work is needed for improving accuracy, the simulated and experimental results demonstrate that accounting for the edge effect is important for determining N leaching from urine-affected areas. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Patch-based frame interpolation for old films via the guidance of motion paths

    Science.gov (United States)

    Xia, Tianran; Ding, Youdong; Yu, Bing; Huang, Xi

    2018-04-01

    Due to improper preservation, traditional films will appear frame loss after digital. To deal with this problem, this paper presents a new adaptive patch-based method of frame interpolation via the guidance of motion paths. Our method is divided into three steps. Firstly, we compute motion paths between two reference frames using optical flow estimation. Then, the adaptive bidirectional interpolation with holes filled is applied to generate pre-intermediate frames. Finally, using patch match to interpolate intermediate frames with the most similar patches. Since the patch match is based on the pre-intermediate frames that contain the motion paths constraint, we show a natural and inartificial frame interpolation. We test different types of old film sequences and compare with other methods, the results prove that our method has a desired performance without hole or ghost effects.

  11. Polymerase chain reaction and blood culture in blood donors screened by ELISA test for Chagas' disease

    Directory of Open Access Journals (Sweden)

    Andréa Tieko Kinoshita-Yanaga

    2011-03-01

    Full Text Available The objective of this study was to evaluate, through blood culture and PCR, the results of the ELISA for Chagas' disease in the screening of blood donors in the public blood-supply network of the state of Paraná, Brazil, and to map the epidemiological profile of the donors with respect to their risk of infection by Trypanosoma cruzi. The negative and positive results of the ELISA were confirmed by blood culture and PCR for 190/191 individuals (99.5%. For one individual (0.5%, the ELISA was inconclusive, blood culture and IIF were negative, and IHA and PCR positive. Three individuals (1.6% were positive for T. cruzi on all the tests. Donors were predominantly female, and natives of Paraná, of rural origin, had observed or been informed of the presence of the vector in the municipalities where they resided, had never received a blood transfusion, had donated blood 1 to 4 times, and reported no cases of Chagas' disease in their families. We concluded that PCR and blood culturing have excellent potential for confirming the results of the ELISA, and that candidate blood donors with negative or positive tests have a similar risk of infection by T. cruzi, indicating that the ELISA test is sufficiently safe for screening blood prior to use.O objetivo deste estudo foi avaliar, pela hemocultura e PCR, os resultados do teste ELISA utilizado para doença de Chagas na triagem de doadores de sangue na rede pública do Estado do Paraná, Brasil, e traçar o perfil epidemiológico dos doadores quanto ao risco de infecção pelo Trypanosoma cruzi. Os resultados negativos e positivos do ELISA foram confirmados pela hemocultura e PCR em 190/191 indivíduos (99,5%. Para um indivíduo (0,5%, o teste de ELISA foi inconclusivo, hemocultura e IFI foram negativas, HAI e PCR foram positivas. Três indivíduos (1,6% foram positivos para T. cruzi em todos os testes. A maioria dos doadores era do sexo feminino, oriundos do Estado do Paraná, de origem rural, tinham

  12. Detection of sodium/water reaction in a steam generator: Results of a 1995 benchmark test

    International Nuclear Information System (INIS)

    Oriol, L.

    1997-01-01

    The CEA analysis of the 1995 benchmark test has been focused on the location of the injections. Two techniques have been tested: the pulse timing technique, and the time-domain delay and sum beamforming technique. The two methods gave coherent locations of the injector even if there was a difference of 25% of the SGU height between the vertical locations. Prior to that analysis, the RMS values of the signals were calculated in different frequency bands. The results obtained in the 200-1000 Hz were used to draw a rough estimation of the beginnings of the injections in order to determine the parts of the records on which the location signal processing can be carried out. (author). 2 refs, 8 figs, 2 tabs

  13. A rivastigmine patch for the treatment of Alzheimer's disease and Parkinson's disease dementia.

    Science.gov (United States)

    Cummings, Jeffrey; Winblad, Bengt

    2007-11-01

    Rivastigmine patch is the first transdermal treatment to be approved for Alzheimer's disease (AD) and Parkinson's disease dementia in the USA and for AD in Europe. It provides smooth, continuous drug delivery, and has the potential to maintain rivastigmine concentrations within an optimal therapeutic window while avoiding the peaks and troughs associated with oral drug delivery. The target dose, rivastigmine 9.5 mg/24 h patch (a 10 cm(2) patch), is given once daily and requires a simple one-step dose titration to the therapeutic dose. In a 24-week study in 1195 AD patients, the rivastigmine 9.5 mg/24 h patch provided similar efficacy to the highest dose range of capsules, with approximately three-times fewer reports of nausea and vomiting. Patients in the 9.5 mg/24 h patch and 12 mg/day capsule groups evidenced significant improvements versus placebo on both primary outcome measures: the Alzheimer's Disease Assessment Scale-Cognitive subscale; and Alzheimer's Disease Cooperative Study-Clinical Global Impression of Change; in addition to the following secondary outcome measures: Alzheimer's Disease Cooperative Study-Activities of Daily Living scale; Mini-Mental State Examination; and Trail Making Test Part A for assessment of attention, visual tracking and motor processing speed. Treatment differences on the Neuropsychiatric Inventory and Ten Point Clock-drawing Test did not reach statistical significance in this study. The patch may be the optimal way to treat dementia patients with rivastigmine.

  14. Boolean Operations with Prism Algebraic Patches

    Science.gov (United States)

    Bajaj, Chandrajit; Paoluzzi, Alberto; Portuesi, Simone; Lei, Na; Zhao, Wenqi

    2009-01-01

    In this paper we discuss a symbolic-numeric algorithm for Boolean operations, closed in the algebra of curved polyhedra whose boundary is triangulated with algebraic patches (A-patches). This approach uses a linear polyhedron as a first approximation of both the arguments and the result. On each triangle of a boundary representation of such linear approximation, a piecewise cubic algebraic interpolant is built, using a C1-continuous prism algebraic patch (prism A-patch) that interpolates the three triangle vertices, with given normal vectors. The boundary representation only stores the vertices of the initial triangulation and their external vertex normals. In order to represent also flat and/or sharp local features, the corresponding normal-per-face and/or normal-per-edge may be also given, respectively. The topology is described by storing, for each curved triangle, the two triples of pointers to incident vertices and to adjacent triangles. For each triangle, a scaffolding prism is built, produced by its extreme vertices and normals, which provides a containment volume for the curved interpolating A-patch. When looking for the result of a regularized Boolean operation, the 0-set of a tri-variate polynomial within each such prism is generated, and intersected with the analogous 0-sets of the other curved polyhedron, when two prisms have non-empty intersection. The intersection curves of the boundaries are traced and used to decompose each boundary into the 3 standard classes of subpatches, denoted in, out and on. While tracing the intersection curves, the locally refined triangulation of intersecting patches is produced, and added to the boundary representation. PMID:21516262

  15. Cutaneous reactions to heparin therapy: when are they caused by heparin allergy?

    Directory of Open Access Journals (Sweden)

    Giuliana Zisa

    2013-03-01

    Full Text Available Introduction: Little is known about the incidence and causes of heparin-induced skin lesions. The most commonly reported causes are delayed-type hypersensitivity reactions. We describe 3 patients who were referred to our staff between March and October 2009 for suspected heparin allergies. All were scheduled to undergo major surgery (cardiovascular or orthopedic. Materials and methods: All 3 patients reported the development of itchy, erythematous rashes a few days after the subcutaneous administration of heparin (nadroparin calcium in cases 1 and 2, unspecified in case 3. Each of them underwent a diagnostic work-up for heparin allergy, which included prick and intradermal tests with commonly used heparins and patch testing with undiluted heparins and disinfectants. Results: Patch tests with disinfectants were negative in all 3 cases. In case 2, all allergological tests were negative. In cases 1 and 3, delayed positivity emerged for nadroparin calcium and at least one other heparin tested. Intravenous and/or subcutaneous provocation testing was done with an alternative heparin which produced negative results in skin tests (heparin sodium in case 1, pentasaccharide fondaparinux in case 3. In both cases the alternative drug was tolerated. After our evaluation, all 3 patients underwent surgery with no heparin-related complications. Discussion: The presenting clinical features in these 3 cases provided no information on which reactions were likely to be allergic: all 3 patients presented with similar local delayed reaction. The allergic reactions were identified only after cutaneous testing.

  16. R/S analysis of reaction time in Neuron Type Test for human activity in civil aviation

    Science.gov (United States)

    Zhang, Hong-Yan; Kang, Ming-Cui; Li, Jing-Qiang; Liu, Hai-Tao

    2017-03-01

    Human factors become the most serious problem leading to accidents of civil aviation, which stimulates the design and analysis of Neuron Type Test (NTT) system to explore the intrinsic properties and patterns behind the behaviors of professionals and students in civil aviation. In the experiment, normal practitioners' reaction time sequences, collected from NTT, exhibit log-normal distribution approximately. We apply the χ2 test to compute the goodness-of-fit by transforming the time sequence with Box-Cox transformation to cluster practitioners. The long-term correlation of different individual practitioner's time sequence is represented by the Hurst exponent via Rescaled Range Analysis, also named by Range/Standard deviation (R/S) Analysis. The different Hurst exponent suggests the existence of different collective behavior and different intrinsic patterns of human factors in civil aviation.

  17. Design of a Composite Membrane with Patches

    International Nuclear Information System (INIS)

    Cuccu, Fabrizio; Emamizadeh, Behrouz; Porru, Giovanni

    2010-01-01

    This paper is concerned with minimization and maximization problems of eigenvalues. The principal eigenvalue of a differential operator is minimized or maximized over a set which is formed by intersecting a rearrangement class with an affine subspace of finite co-dimension. A solution represents an optimal design of a 2-dimensional composite membrane Ω, fixed at the boundary, built out of two different materials, where certain prescribed regions (patches) in Ω are occupied by both materials. We prove existence results, and present some features of optimal solutions. The special case of one patch is treated in detail.

  18. Generic Patch Inference

    DEFF Research Database (Denmark)

    Andersen, Jesper; Lawall, Julia Laetitia

    2008-01-01

    A key issue in maintaining Linux device drivers is the need to update drivers in response to evolutions in Linux internal libraries. Currently, there is little tool support for performing and documenting such changes. In this paper we present a tool, spfind, that identifies common changes made...... developers can use it to extract an abstract representation of the set of changes that others have made. Our experiments on recent changes in Linux show that the inferred generic patches are more concise than the corresponding patches found in commits to the Linux source tree while being safe with respect...

  19. An introduction to the 'Psycho-Physiological-Stress-Test' (PPST-A standardized instrument for evaluating stress reactions.

    Directory of Open Access Journals (Sweden)

    Elisabeth Neureiter

    Full Text Available Using a standardized instrument to evaluate patients' stress reactions has become more important in daily clinical routines. Different signs or symptoms of stress are often unilaterally explored: the physiological, psychological or social aspects of stress disorders are each viewed on a single dimension. However, all dimensions afflict patients who have persistent health problems due to chronic stress. Therefore, it is important to use a multidimensional approach to acquire data. The 'Psycho-Physiological-Stress-Test' (PPST was established to achieve a comprehensive understanding of stress and was further developed at the Charité-Universitätsmedizin Berlin in collaboration with the Psychological Department of Freie Universität Berlin. The PPST includes a series of varying stress phases, embedded in two periods of rest. Physiological and psychological parameters are simultaneously measured throughout the test session. Specifically, the PPST activates the sympathetic stress axis, which is measured by heart rate, blood pressure, respiration depth and rate, electro dermal activation and muscle tension (frontalis, masseter, trapezius. Psychological data are simultaneously collected, and include performance, motivation, emotion and behavior. After conducting this diagnostic test, it is possible to identify individual stress patterns that can be discussed with the individual patient to develop and recommend (outpatient treatment strategies. This paper introduces the PPST as a standardized way to evaluate stress reactions by presenting the results from a sample of psychosomatic inpatients (n = 139 who were treated in Charité-Universitätsmedizin Berlin, Germany. We observed that the varying testing conditions provoked adjusted changes in the different physiological parameters and psychological levels.

  20. Detection of clarithromycin-resistant Helicobacter pylori by polymerase chain reaction using residual samples from rapid urease test

    Directory of Open Access Journals (Sweden)

    Jae-Sik Jeon

    2017-01-01

    Full Text Available Background: Approximately 50% of the world population is infected with Helicobacter pylori, which corresponds to a high infection rate. Furthermore, the incidence of antibiotic-resistant H. pylori has increased with the recent rise in use of antibiotics for H. pylori elimination, suggesting growing treatment failures. Aim: The study was aimed to assess the use of residual samples from rapid urease test (RUT for biomolecular testing as an effective and accurate method to detect antibiotic-resistant H. pylori. Settings and Design: This study was a retrospective study performed using data obtained from medical records of previously isolated H. pylori strains. Materials and Methods: RUT was conducted for 5440 biopsy samples from individuals who underwent health examination in South Korea. Subsequently, 469 RUT residual samples were randomly selected and subjected to polymerase chain reaction (PCR to detect antibiotic-resistant H. pylori. Statistical Analysis Used: The Chi-square test was used to analyse categorical data. P < 0.05 was considered statistically significant. Results: The results showed a concordance between the results of PCR and conventional RUT in 450 of 469 samples, suggesting that the H. pylori PCR test is a time- and cost-effective detection method. Conclusions: This study demonstrated that PCR test can aid physicians to prescribe the appropriate antibiotics at the time of diagnosis, thus preventing the reduction in H. pylori eradication due to antibiotic resistance, averting progression to serious diseases and increasing the treatment success rate.

  1. A Laboratory Test Setup for in Situ Measurements of the Dielectric Properties of Catalyst Powder Samples under Reaction Conditions by Microwave Cavity Perturbation: Set up and Initial Tests

    Directory of Open Access Journals (Sweden)

    Markus Dietrich

    2014-09-01

    Full Text Available The catalytic behavior of zeolite catalysts for the ammonia-based selective catalytic reduction (SCR of nitrogen oxides (NOX depends strongly on the type of zeolite material. An essential precondition for SCR is a previous ammonia gas adsorption that occurs on acidic sites of the zeolite. In order to understand and develop SCR active materials, it is crucial to know the amount of sorbed ammonia under reaction conditions. To support classical temperature-programmed desorption (TPD experiments, a correlation of the dielectric properties with the catalytic properties and the ammonia sorption under reaction conditions appears promising. In this work, a laboratory test setup, which enables direct measurements of the dielectric properties of catalytic powder samples under a defined gas atmosphere and temperature by microwave cavity perturbation, has been developed. Based on previous investigations and computational simulations, a resonator cavity and a heating system were designed, installed and characterized. The resonator cavity is designed to operate in its TM010 mode at 1.2 GHz. The first measurement of the ammonia loading of an H-ZSM-5 zeolite confirmed the operating performance of the test setup at constant temperatures of up to 300 °C. It showed how both real and imaginary parts of the relative complex permittivity are strongly correlated with the mass of stored ammonia.

  2. A laboratory test setup for in situ measurements of the dielectric properties of catalyst powder samples under reaction conditions by microwave cavity perturbation: set up and initial tests.

    Science.gov (United States)

    Dietrich, Markus; Rauch, Dieter; Porch, Adrian; Moos, Ralf

    2014-09-10

    The catalytic behavior of zeolite catalysts for the ammonia-based selective catalytic reduction (SCR) of nitrogen oxides (NOX) depends strongly on the type of zeolite material. An essential precondition for SCR is a previous ammonia gas adsorption that occurs on acidic sites of the zeolite. In order to understand and develop SCR active materials, it is crucial to know the amount of sorbed ammonia under reaction conditions. To support classical temperature-programmed desorption (TPD) experiments, a correlation of the dielectric properties with the catalytic properties and the ammonia sorption under reaction conditions appears promising. In this work, a laboratory test setup, which enables direct measurements of the dielectric properties of catalytic powder samples under a defined gas atmosphere and temperature by microwave cavity perturbation, has been developed. Based on previous investigations and computational simulations, a resonator cavity and a heating system were designed, installed and characterized. The resonator cavity is designed to operate in its TM010 mode at 1.2 GHz. The first measurement of the ammonia loading of an H-ZSM-5 zeolite confirmed the operating performance of the test setup at constant temperatures of up to 300 °C. It showed how both real and imaginary parts of the relative complex permittivity are strongly correlated with the mass of stored ammonia.

  3. Linear Array Ultrasonic Test Results from Alkali-Silica Reaction (ASR) Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Khazanovich, Dr. Lev [Univ. of Minnesota, Minneapolis, MN (United States); Salles, Lucio [Univ. of Minnesota, Minneapolis, MN (United States)

    2016-04-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations.This report presents results of the ultrasound evaluation of four concrete slabs with varying levels of ASR damage present. This included an investigation of the experimental results, as well as a supplemental simulation considering the effect of ASR damage by elasto-dynamic wave propagation using a finite integration technique method. It was found that the Hilbert Transform Indicator (HTI), developed for quantification of freeze/thaw damage in concrete structures, could also be successfully utilized for quantification of ASR damage. internal microstructure flaws, and reinforcement locations.

  4. Design and testing of an armature-reaction-compensated permanent magnet synchronous generator for island operation

    Energy Technology Data Exchange (ETDEWEB)

    Kamiev, K.

    2013-11-01

    At present, permanent magnet synchronous generators (PMSGs) are of great interest. Since they do not have electrical excitation losses, the highly efficient, lightweight and compact PMSGs equipped with damper windings work perfectly when connected to a network. However, in island operation, the generator (or parallel generators) alone is responsible for the building up of the network and maintaining its voltage and reactive power level. Thus, in island operation, a PMSG faces very tight constraints, which are difficult to meet, because the flux produced by the permanent magnets (PMs) is constant and the voltage of the generator cannot be controlled. Traditional electrically excited synchronous generators (EESGs) can easily meet these constraints, because the field winding current is controllable. The main drawback of the conventional EESG is the relatively high excitation loss. This doctoral thesis presents a study of an alternative solution termed as a hybrid excitation synchronous generator (HESG). HESGs are a special class of electrical machines, where the total rotor current linkage is produced by the simultaneous action of two different excitation sources: the electrical and permanent magnet (PM) excitation. An overview of the existing HESGs is given. Several HESGs are introduced and compared with the conventional EESG from technical and economic points of view. In the study, the armature-reaction-compensated permanent magnet synchronous generator with alternated current linkages (ARC-PMSG with ACL) showed a better performance than the other options. Therefore, this machine type is studied in more detail. An electromagnetic design and a thermal analysis are presented. To verify the operation principle and the electromagnetic design, a down-sized prototype of 69 kVA apparent power was built. The experimental results are demonstrated and compared with the predicted ones. A prerequisite for an ARC-PMSG with ACL is an even number of pole pairs (p = 2, 4, 6

  5. [Use of pharmacogenetic testing to prevent adverse drug reactions during statin therapy].

    Science.gov (United States)

    Rumyantsev, N A; Kukes, V G; Kazakov, R E; Rumyantsev, A A; Sychev, D A

    The number of patients receiving statins increases every year and due to the fact that they should take statins during their lives, the problem of their safety use comes to the forefront. The paper analyzes the safety of using the medications of this group and discusses the diagnosis of myopathies induced by statins and the occurrence of immune-mediated statin myopathies. It considers a personalized approach to prescribing statins, analyzes Russian and foreign experience in using pharmacogenetics to reduce the risk of myopathies, publishes the results of the authors' experience in clinically introducing pharmacogenetic testing at hospitals, and analyzes the long-term results of determining the polymorphism of the SLCO1B1 gene for the prediction of the risk of adverse events when using statins and estimating patient compliance to prescribed treatment.

  6. A Field Study of Participant Reactions to a Developmental Assessment Centre: Testing an organisational justice model

    Directory of Open Access Journals (Sweden)

    Michael M Harris

    2008-06-01

    Full Text Available Although assessment centres are being increasingly employed for developmental purposes, there has been a dearth of research regarding them. We investigated an organisational justice theory model suggested by Cohen-Charash and Spector (2001 in this relatively novel context. The model included antecedents (e.g., perceived validity, organisational justice perceptions (i.e., distributive justice and procedural justice, and one outcome (i.e., feedback utility perceptions. Most of our hypotheses were supported, suggesting much evidence for this model. The predicted effect for perceived fakability was not supported. Contrary to our hypothesis, distributive justice perceptions were at least as important as procedural justice perceptions in predicting feedback utility perceptions. A direct test of the effect of context on organisational justice theory is recommended.

  7. [Academic discussion of adverse reaction of clinical trials of new traditional Chinese medicines and relevant influencing factors].

    Science.gov (United States)

    Wang, Wen-ping; Yu, Ming; Wang, Li; Jiang, Xi-ren; Li, Xiao-bin; Wang, Hua-wei; Cao, Ying; Liu, Kai; Huang, Lu-qi

    2015-01-01

    Data of clinical trial projects involved by clinical trial institutions certified by the State Food and Drug Administration from 2002 to November 2012 were collected to summarize adverse reactions in project summary/statistical reports, analyze the rate of adverse reactions of clinical trials of new traditional Chinese medicines and relevant influencing factors, and increase the awareness of the safety of new traditional Chinese medicines. A total of 73 050 cases in 209 projects of 14 specialties were collected, including 49 689 cases in the new traditional Chinese medicine group and 271 adverse reaction cases, with an incidence rate of adverse reactions at 0.55%. The adverse reaction rate in 3 months 0.63% for injection > 0.50% for oral. In the administration of only the test drug, the adverse reaction rate of patches was the highest (2.68%), whereas that of aerosols and suppositories was lowest (0). In the combined administration of the test drug and the simulation agent, the adverse reaction rate of external test patch + capsule was the highest (3.38%), whereas that of capsule + oral liquid, pills + granules, tablets + oral liquid, tablets + pills, tablet + capsule was the lowest (0). In the administration of only the test drug, the adverse reaction rate was 0.47%; In the combined administration with simulation agent (drug volume increase), the adverse reaction rate was 0.74%. Different doses caused adverse reaction different rates; The adverse reaction rate of drugs with whole-course dose between 1 100-1 200 g was the highest (3.36%), that for whole-course doses of 500-600, 900-1 000, 1 400-1 500, 1 600-1 700, 1 800-1 900 g was the lowest (0). In conclusion, the adverse reaction rate of new traditional Chinese medicines was still up to 0.55%, with the adverse reaction rate between 0.47% and 0.72% over the 11 years, without significant difference in each year. The adverse reaction rate was closely related to course of treatment, approach of administration

  8. Topical lidocaine patch 5% for acute postoperative pain control.

    LENUS (Irish Health Repository)

    Gilhooly, D

    2011-02-01

    A 39-year-old para 3 woman presented for elective caesarean section (lower segment caesarean section (LSCS)) for breech presentation. The patient had a strong history of atopy and anaphylaxis to paracetamol, codeine, penicillin and latex. The patient was asthmatic, triggered by aspirin. Epidural anaesthesia was unsuccessful and LSCS was carried out under spinal anaesthesia. Postoperatively the patient was unwilling to take analgesic medication due to fear of an allergic reaction. Three 5% lidocaine patches were applied to the wound for postoperative analgesia. This reduced the patient\\'s visual analogue scale pain score from 10\\/10 to 5\\/10 at rest and 10\\/10 to 7\\/10 with movement. Transcutaneous electrical nerve stimulation was added and this improved associated back pain, reducing the pain further to 2\\/10. This is the first description of lignocaine patch 5% for postoperative LSCS pain. It is suggested that this method of delivery of local anaesthetic, which is easy to apply and has minimal side effects, should be considered not as a sole agent but as part of a multimodal technique to address postoperative LSCS pain.

  9. Performance test results of helium gas circulator of mock-up test facility with full-scale reaction tube for HTTR hydrogen production system. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Akira; Kato, Michio; Hayashi, Koji [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2003-03-01

    Hydrogen production system by steam reforming of methane will be connected to the High Temperature Engineering Test Reactor (HTTR) of the Japan Atomic Energy Research Institute (JAERI) against development of nuclear heat utilization system. To obtain design and safety database of the HTTR hydrogen production system, mock-up test facility with full-scale reaction was constructed in FY 2001 and hydrogen of 120m{sup 3}N{sub /}h was successfully produced in overall performance test. This report describes performance test results of a helium gas circulator in this facility. The circulator performance curves regarding to pressure-rise, input power and adiabatic thermal efficiency at standard revolution number were made based on the measured flow-rate, temperature and pressure data in overall performance test. The circulator performance prediction code was made based on these performance curves. The code can calculate revolution number, electric power and temperature-rise of the circulator using flow-rate, inlet temperature, inlet pressure and pressure-rise data. The verification of the code was carried out with the test data in FY 2002. Total pressure loss of the helium gas circulation loop was also evaluated. The circulator should be operated in conditions such as pressure from 2.7MPa to 4.0MPa and flow-rate from 250g/s to 400g/s and at maximum pressure-rise of 250 kPa in test operation. It was confirmed in above verification and evaluations that the circulator had performance to satisfy above conditions within operation limitation of the circulator such as maximum input-power of 150 kW and maximum revolution number of 12,000 rpm. (author)

  10. Emotional reaction evaluation provoked by the vestibular caloric test through physiological variables monitoring.

    Science.gov (United States)

    Barona-de-Guzmán, Rafael; Krstulovic-Roa, Claudio; Donderis-Malea, Elena; Barona-Lleó, Luz

    2018-03-08

    The emotional evaluation of the causes of vertigo is made using the clinical records and several subjective questionnaires. The aim of the present study is to evaluate the emotional response objectively, in normal subjects, during an induced vertigo crisis. A caloric vestibular test with cold water was performed on 30 healthy subjects. The following physiological parameters were monitored during the 60seconds prior to and the 60seconds after the stimulation: Skin Conductivity, Peripheral Pulse Volume, Body Temperature, Muscle Contraction, Heart Rate, and Respiratory Rate. The maximum angular speed of the nystagmus slow phase at each stimulation was assessed. Skin conductance presented a statistically significant increase during the vertigo crisis in relation to the prior period while the peripheral pulse volume presented a statistically significant decrease. There was no relationship between the slow phase of the provoked nystagmus angular speed and skin conductance and peripheral pulse volume changes. The decrease in peripheral pulse volume was significantly higher in the second vertigo crisis. Skin conductance and peripheral pulse volume changed significantly during a vertigo crisis. There was no relation between the provoked vertiginous crisis intensity and the changes produced in those variables. The stress generated by the caloric stimulation is higher in the second crisis, when the subject has experience of the vertigo caused by the stimulation. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. A method for detecting hydrophobic patches protein

    NARCIS (Netherlands)

    Lijnzaad, P.; Berendsen, H.J.C.; Argos, P.

    1996-01-01

    A method for the detection of hydrophobic patches on the surfaces of protein tertiary structures is presented, it delineates explicit contiguous pieces of surface of arbitrary size and shape that consist solely of carbon and sulphur atoms using a dot representation of the solvent-accessible surface,

  12. Evaluation of winter pothole patching methods.

    Science.gov (United States)

    2014-01-01

    The main objective of this study was to evaluate the performance and cost-effectiveness of the tow-behind combination : infrared asphalt heater/reclaimer patching method and compare it to the throw and roll and spray injection methods. To : achieve t...

  13. Active patch antennas for transponder applications

    Energy Technology Data Exchange (ETDEWEB)

    Biffi Gentili, G; Avitabile, G; Bonifacio, F; Salvador, C [Florence Univ. (Italy). Dip. di Ingegneria Elettronica

    1996-01-01

    The paper deals with two patch antenna structures that are mainly taught for short range link and non-contact identification system (RFID). The proposed antennas were developed by starting from an original concept of cross-polarization usefully applicable, in compliance with european for transponder applications are described and experimental results are reported.

  14. Perturbation analysis for patch occupancy dynamics

    Science.gov (United States)

    Martin, Julien; Nichols, James D.; McIntyre, Carol L.; Ferraz, Goncalo; Hines, James E.

    2009-01-01

    Perturbation analysis is a powerful tool to study population and community dynamics. This article describes expressions for sensitivity metrics reflecting changes in equilibrium occupancy resulting from small changes in the vital rates of patch occupancy dynamics (i.e., probabilities of local patch colonization and extinction). We illustrate our approach with a case study of occupancy dynamics of Golden Eagle (Aquila chrysaetos) nesting territories. Examination of the hypothesis of system equilibrium suggests that the system satisfies equilibrium conditions. Estimates of vital rates obtained using patch occupancy models are used to estimate equilibrium patch occupancy of eagles. We then compute estimates of sensitivity metrics and discuss their implications for eagle population ecology and management. Finally, we discuss the intuition underlying our sensitivity metrics and then provide examples of ecological questions that can be addressed using perturbation analyses. For instance, the sensitivity metrics lead to predictions about the relative importance of local colonization and local extinction probabilities in influencing equilibrium occupancy for rare and common species.

  15. Soil, Seeds, and the Pumpkin Patch!

    Science.gov (United States)

    Phillips, Marianne; Vowell, Julie

    2013-01-01

    "Soil, Seeds, and the Pumpkin Patch!" is an integrated unit designed to provide elementary school teachers with ideas for using hands-on activities, fostering inquiry and valuable discussion, and using technology as a learning tool. This unit integrates science with language arts, mathematics, literature, and technology. During this unit, students…

  16. An Active Patch Model for Real World Texture and Appearance Classification.

    Science.gov (United States)

    Mao, Junhua; Zhu, Jun; Yuille, Alan L

    2014-09-06

    This paper addresses the task of natural texture and appearance classification. Our goal is to develop a simple and intuitive method that performs at state of the art on datasets ranging from homogeneous texture (e.g., material texture), to less homogeneous texture (e.g., the fur of animals), and to inhomogeneous texture (the appearance patterns of vehicles). Our method uses a bag-of-words model where the features are based on a dictionary of active patches. Active patches are raw intensity patches which can undergo spatial transformations (e.g., rotation and scaling) and adjust themselves to best match the image regions. The dictionary of active patches is required to be compact and representative, in the sense that we can use it to approximately reconstruct the images that we want to classify. We propose a probabilistic model to quantify the quality of image reconstruction and design a greedy learning algorithm to obtain the dictionary. We classify images using the occurrence frequency of the active patches. Feature extraction is fast (about 100 ms per image) using the GPU. The experimental results show that our method improves the state of the art on a challenging material texture benchmark dataset (KTH-TIPS2). To test our method on less homogeneous or inhomogeneous images, we construct two new datasets consisting of appearance image patches of animals and vehicles cropped from the PASCAL VOC dataset. Our method outperforms competing methods on these datasets.

  17. Hyaluronic acid microneedle patch for the improvement of crow's feet wrinkles.

    Science.gov (United States)

    Choi, Sun Young; Kwon, Hyun Jung; Ahn, Ga Ram; Ko, Eun Jung; Yoo, Kwang Ho; Kim, Beom Joon; Lee, Changjin; Kim, Daegun

    2017-11-01

    Hyaluronic acid (HA) has an immediate volumizing effect, due to its strong water-binding potential, and stimulates fibroblasts, causing collagen synthesis, with short- and long-term effects on wrinkle improvement. We investigated the efficacy and safety of HA microneedle patches for crow's feet wrinkles. Using a randomized spilt-face design, we compared microneedle patches with a topical application containing the same active ingredients. We enrolled 34 Korean female subjects with mild to moderate crow's feet wrinkles. The wrinkle on each side of the subject's face was randomly assigned to a HA microneedle patch or HA essence application twice a week for 8 weeks. Efficacy was evaluated at weeks 2, 4, and 8. Skin wrinkles were measured as average roughness using replica and PRIMOS. Skin elasticity was assessed using a cutometer. Two independent blinded dermatologists evaluated the changes after treatment using the global visual wrinkle assessment score. Subjects assessed wrinkles using the subject global assessment score. Skin wrinkles were significantly reduced and skin elasticity significantly increased in both groups, although improvement was greater in the patch group at week 8 after treatment. In the primary and cumulative skin irritation tests, the HA microneedle patch did not induce any skin irritation. The HA microneedle patch is more effective than the HA essence for wrinkle improvement and is a safe and convenient without skin irritation. © 2017 Wiley Periodicals, Inc.

  18. Long-term stability of influenza vaccine in a dissolving microneedle patch.

    Science.gov (United States)

    Mistilis, Matthew J; Joyce, Jessica C; Esser, E Stein; Skountzou, Ioanna; Compans, Richard W; Bommarius, Andreas S; Prausnitz, Mark R

    2017-04-01

    This study tested the hypothesis that optimized microneedle patch formulations can stabilize trivalent subunit influenza vaccine during long-term storage outside the cold chain and when exposed to potential stresses found during manufacturing and storage. Formulations containing combinations of trehalose/sucrose, sucrose/arginine, and arginine/heptagluconate were successful at retaining most or all vaccine activity during storage at 25 °C for up to 24 months as determined by ELISA assay. The best formulation of microneedle patches contained arginine/heptagluconate, which showed no significant loss of vaccine activity during the study. To validate these in vitro findings, mice were immunized using trivalent influenza vaccine stored in microneedle patches for more than 1 year at 25 °C, which elicited antibody titers greater than or equal to fresh liquid vaccine delivered by intradermal injection, indicating the retention of immunogenicity during storage. Finally, influenza vaccine in microneedle patches lost no significant activity during exposure to 60 °C for 4 months, multiple freeze-thaw cycles, or electron beam irradiation. We conclude that optimally formulated microneedle patches can retain influenza vaccine activity during extended storage outside the cold chain and during other environmental stresses, which suggests the possibility of microneedle patch storage on pharmacy shelves without refrigeration.

  19. PatchSurfers: Two methods for local molecular property-based binding ligand prediction.

    Science.gov (United States)

    Shin, Woong-Hee; Bures, Mark Gregory; Kihara, Daisuke

    2016-01-15

    Protein function prediction is an active area of research in computational biology. Function prediction can help biologists make hypotheses for characterization of genes and help interpret biological assays, and thus is a productive area for collaboration between experimental and computational biologists. Among various function prediction methods, predicting binding ligand molecules for a target protein is an important class because ligand binding events for a protein are usually closely intertwined with the proteins' biological function, and also because predicted binding ligands can often be directly tested by biochemical assays. Binding ligand prediction methods can be classified into two types: those which are based on protein-protein (or pocket-pocket) comparison, and those that compare a target pocket directly to ligands. Recently, our group proposed two computational binding ligand prediction methods, Patch-Surfer, which is a pocket-pocket comparison method, and PL-PatchSurfer, which compares a pocket to ligand molecules. The two programs apply surface patch-based descriptions to calculate similarity or complementarity between molecules. A surface patch is characterized by physicochemical properties such as shape, hydrophobicity, and electrostatic potentials. These properties on the surface are represented using three-dimensional Zernike descriptors (3DZD), which are based on a series expansion of a 3 dimensional function. Utilizing 3DZD for describing the physicochemical properties has two main advantages: (1) rotational invariance and (2) fast comparison. Here, we introduce Patch-Surfer and PL-PatchSurfer with an emphasis on PL-PatchSurfer, which is more recently developed. Illustrative examples of PL-PatchSurfer performance on binding ligand prediction as well as virtual drug screening are also provided. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Light transmission and preference of eye patches for occlusion treatment.

    Directory of Open Access Journals (Sweden)

    Hwan Heo

    Full Text Available To investigate light transmission and preference for six eye patches for occlusion therapy.Six patches were examined, including; Ortopad Fun Pack, Ortopad Flesh, Kawamoto A-1, Kawamoto A-2, 3M Opticlude, and Everade Eye Guard. The size and the presence of a light blocking pad of patches were investigated. The amount of light transmitted through the patches was evaluated, using a digital light meter and a model eye, in three different environments; indoors with fluorescent light, outdoors on a sunny day, and strong light from illuminator. After patching the normal eye, the flash visual evoked potential (VEP was measured. Thirty patients with amblyopia or horizontal strabismus, who received occlusion therapy as initial treatment, were included. After using all six patches, patients completed a 7-item questionnaire regarding the patch preference for size, color and shape, adhesive power, pain with removal, skin irritation after removing patch, parent's preference and overall opinion.All patches had a light-blocking pad, except the 3M Nexcare. Ortopad had the strongest light blocking power in the three environments, and the 3M Nexcare had the weakest power. In flash VEP, Ortopad and Kawamoto patches showed flat, but 3M Nexcare and Everade Eye Guard showed normal response. There were significant preferential differences among the patches in all the items of the questionnaire (P<0.05. In comparison between the patches respectively, 3M Nexcare received the lowest satisfaction in pain when removing a patch and skin irritation after removing a patch. Kawamoto A-2 received the lowest score in the overall satisfaction.We found differences in the light-blocking power and in the preference of the various patches for the occlusion treatment. This is a pilot study regarding only characteristics and preferences of patches. Further clinical studies regarding the relationship between characteristics or preferences of patches and outcomes of occlusion treatment

  1. Ultrasonic techniques for repair of aircraft structures with bonded composite patches

    Science.gov (United States)

    Smith, S. H.; Senapati, N.; Francini, R. B.

    1994-01-01

    This is a paper on a research and development project to demonstrate a novel ultrasonic process for the field application of boron/epoxy (B/Ep) patches for repair of aircraft structures. The first phase of the project was on process optimization and testing to develop the most practical ultrasonic processing techniques. Accelerated testing and aging behavior of precured B/Ep patches, which were ultrasonically bonded to simulated B-52 wing panel assemblies, were performed by conducting flight-by-flight spectrum loading fatigue tests. The spectrum represented 2340 missions/flights or 30 years of service. The effects of steady-state applied temperature and prior exposure of the B/Ep composite patches were evaluated. Representative experimental results of this phase of the project are presented.

  2. Potential testing of reprocessing procedures by real-time polymerase chain reaction: A multicenter study of colonoscopy devices.

    Science.gov (United States)

    Valeriani, Federica; Agodi, Antonella; Casini, Beatrice; Cristina, Maria Luisa; D'Errico, Marcello Mario; Gianfranceschi, Gianluca; Liguori, Giorgio; Liguori, Renato; Mucci, Nicolina; Mura, Ida; Pasquarella, Cesira; Piana, Andrea; Sotgiu, Giovanni; Privitera, Gaetano; Protano, Carmela; Quattrocchi, Annalisa; Ripabelli, Giancarlo; Rossini, Angelo; Spagnolo, Anna Maria; Tamburro, Manuela; Tardivo, Stefano; Veronesi, Licia; Vitali, Matteo; Romano Spica, Vincenzo

    2018-02-01

    Reprocessing of endoscopes is key to preventing cross-infection after colonoscopy. Culture-based methods are recommended for monitoring, but alternative and rapid approaches are needed to improve surveillance and reduce turnover times. A molecular strategy based on detection of residual traces from gut microbiota was developed and tested using a multicenter survey. A simplified sampling and DNA extraction protocol using nylon-tipped flocked swabs was optimized. A multiplex real-time polymerase chain reaction (PCR) test was developed that targeted 6 bacteria genes that were amplified in 3 mixes. The method was validated by interlaboratory tests involving 5 reference laboratories. Colonoscopy devices (n = 111) were sampled in 10 Italian hospitals. Culture-based microbiology and metagenomic tests were performed to verify PCR data. The sampling method was easily applied in all 10 endoscopy units and the optimized DNA extraction and amplification protocol was successfully performed by all of the involved laboratories. This PCR-based method allowed identification of both contaminated (n = 59) and fully reprocessed endoscopes (n = 52) with high sensibility (98%) and specificity (98%), within 3-4 hours, in contrast to the 24-72 hours needed for a classic microbiology test. Results were confirmed by next-generation sequencing and classic microbiology. A novel approach for monitoring reprocessing of colonoscopy devices was developed and successfully applied in a multicenter survey. The general principle of tracing biological fluids through microflora DNA amplification was successfully applied and may represent a promising approach for hospital hygiene. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  3. Continued evaluation of pothole patching equipment, materials, and processes.

    Science.gov (United States)

    2014-06-14

    After the deaths of two Caltrans workers who were patching potholes in 2006-2007, Caltrans tasked the Advanced Highway Maintenance and Construction Technology (AHMCT) Research Center with developing a safer and more efficient means of patching pothol...

  4. Characteristic evolutions in numerical relativity using six angular patches

    International Nuclear Information System (INIS)

    Reisswig, Christian; Bishop, Nigel T; Lai, Chi Wai; Thornburg, Jonathan; Szilagyi, Bela

    2007-01-01

    The characteristic approach to numerical relativity is a useful tool in evolving gravitational systems. In the past this has been implemented using two patches of stereographic angular coordinates. In other applications, a six-patch angular coordinate system has proved effective. Here we investigate the use of a six-patch system in characteristic numerical relativity, by comparing an existing two-patch implementation (using second-order finite differencing throughout) with a new six-patch implementation (using either second- or fourth-order finite differencing for the angular derivatives). We compare these different codes by monitoring the Einstein constraint equations, numerically evaluated independently from the evolution. We find that, compared to the (second-order) two-patch code at equivalent resolutions, the errors of the second-order six-patch code are smaller by a factor of about 2, and the errors of the fourth-order six-patch code are smaller by a factor of nearly 50

  5. Characteristic evolutions in numerical relativity using six angular patches

    Energy Technology Data Exchange (ETDEWEB)

    Reisswig, Christian [Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, D-14476 Golm (Germany); Bishop, Nigel T [Department of Mathematical Sciences, University of South Africa, PO Box 392, Unisa 0003, South Africa (South Africa); Lai, Chi Wai [Department of Mathematical Sciences, University of South Africa, PO Box 392, Unisa 0003, South Africa (South Africa); Thornburg, Jonathan [Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, D-14476 Golm (Germany); Szilagyi, Bela [Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, D-14476 Golm (Germany)

    2007-06-21

    The characteristic approach to numerical relativity is a useful tool in evolving gravitational systems. In the past this has been implemented using two patches of stereographic angular coordinates. In other applications, a six-patch angular coordinate system has proved effective. Here we investigate the use of a six-patch system in characteristic numerical relativity, by comparing an existing two-patch implementation (using second-order finite differencing throughout) with a new six-patch implementation (using either second- or fourth-order finite differencing for the angular derivatives). We compare these different codes by monitoring the Einstein constraint equations, numerically evaluated independently from the evolution. We find that, compared to the (second-order) two-patch code at equivalent resolutions, the errors of the second-order six-patch code are smaller by a factor of about 2, and the errors of the fourth-order six-patch code are smaller by a factor of nearly 50.

  6. Performance of patch repaired composite panels under fatigue loads

    International Nuclear Information System (INIS)

    Darwish, Feras H.; Hamoush, S.; Shivakumar, K.

    2006-01-01

    This paper evaluates the performance of bonded patch-scarf repairs of full scale laminated composite panels under cyclic load conditions. Nondestructive testing to characterize the quality of repairs and destructive testing to evaluate the performance of repaired panels were used in this study. Carbon/Epoxy prepreg material used was used to lay up six-ply (12 in. x 27 in. /305x686mm) (-60/60/0) s quasi-isotropic laminates. 7-ply scarf repair with a gradient of 0.5 inch (12.7mm) per layer was used to perform the repair of a damaged zone. The patch consisted of 7.5 inches (190mm) diameter adhesive film, 1 inch (25.4mm) diameter filler ply at 90fiber orientation, and six plies (2-7 inches (51-178mm) diameter) to match the lay-up of the parent material. The study was extended to include defective repairs. The defect was engineered by inserting a 1 inch (25.4 mm) circular Teflon flaw between the fifth and sixth layers of the patch. A total of 28 panels were prepared and divided into five categories: (1) three pristine panels (undamaged parental materials); (2) three damaged panels (1-inch-centered-hole); (3) two repaired panels with wrong fiber orientation; (4) nine good repaired panels, and (5) eleven defective repair panels (1 inch flaw). A nondestructive evaluation to check the conditions of the repairs was performed on most of the tested panels that include the pulse-echo C-scan and pseudo through transmission air coupled and water coupled C-scan. Based on the results of the experimental evaluation of this study, good repair restored 95% of the tensile strength while defective repair restored 90% of the tensile strength of the pristine panels. Under fatigue loading, panels repaired with a 1 inch delamination flaw within the patch layers showed a major reduction in fatigue life compared to the good repair panels under similar loading conditions. (author)

  7. Development of a test for recording both visual and auditory reaction times, potentially useful for future studies in patients on opioids therapy

    Directory of Open Access Journals (Sweden)

    Miceli L

    2015-02-01

    Full Text Available Luca Miceli,1 Rym Bednarova,2 Alessandro Rizzardo,1 Valentina Samogin,1 Giorgio Della Rocca1 1Department of Anesthesia and Intensive Care Medicine, University of Udine, 2Department of Pain Medicine and Palliative Care, Hospital of Latisana, Latisana, Udine, Italy Objective: Italian Road Law limits driving while undergoing treatment with certain kinds of medication. Here, we report the results of a test, run as a smartphone application (app, assessing auditory and visual reflexes in a sample of 300 drivers. The scope of the test is to provide both the police force and medication-taking drivers with a tool that can evaluate the individual’s capacity to drive safely. Methods: The test is run as an app for Apple iOS and Android mobile operating systems and facilitates four different reaction times to be assessed: simple visual and auditory reaction times and complex visual and auditory reaction times. Reference deciles were created for the test results obtained from a sample of 300 Italian subjects. Results lying within the first three deciles were considered as incompatible with safe driving capabilities. Results: Performance is both age-related (r>0.5 and sex-related (female reaction times were significantly slower than those recorded for male subjects, P<0.05. Only 21% of the subjects were able to perform all four tests correctly. Conclusion: We developed and fine-tuned a test called Safedrive that measures visual and auditory reaction times through a smartphone mobile device; the scope of the test is two-fold: to provide a clinical tool for the assessment of the driving capacity of individuals taking pain relief medication; to promote the sense of social responsibility in drivers who are on medication and provide these individuals with a means of testing their own capacity to drive safely. Keywords: visual reaction time, auditory reaction time, opioids, Safedrive

  8. Wastage-resistant characteristics of 12Cr steel tube material. Small leak sodium-water reaction test

    International Nuclear Information System (INIS)

    Shimoyama, Kazuhito

    2004-03-01

    In the water leak accident of a steam generator designed for a sodium cooled reactor in the Feasibility Study, the localization of tube failure propagation by using an advanced water leak detector will be required from the viewpoints of the safety and economical efficiency of the plant. So far, the conventional knowledge and analytical tools have been used in the investigation and evaluation of water leak phenomenon; nevertheless, there was neither test data nor the study of quantitative evaluation on the corrosion behavior, so-called wastage-resistant characteristics, of 12Cr steel tube material in sodium-water reactions. Wastage tests for the 12Cr steel tube material were conducted in small water leaks by use of the Sodium-Water Reaction Test Rig (SWAT-1R), and the data of wastage rate were obtained in the parameter of water leak rate under the constant sodium temperature and distance between leak and target tubes. The test results lead to the following conclusions: (1) The wastage-resistibility of 12Cr steel is 1.6 times greater than that of 9Cr steel and is 2.7 times greater than that of 2.25Cr-1Mo steel. (2)The wastage-resistibility of 12Cr steel increases in smaller water leaks; especially in water leak rates of 1 g/sec or less, it is more excellent than that of SUS321 stainless steel used as Monju superheater tube material. (3) Based on the correlation of wastage rate for the 9Cr steel, the correlation for the 12Cr steel has been obtained to be used for the evaluation of tube failure propagation. As the correlation of wastage rate for the 12Cr steel is based on the correlation for the 9Cr steel, it gives enough conservatism in smaller water leaks. To serve in accurately evaluating the tube failure propagation in smaller water leaks, it is necessary to obtain new correlation of wastage rate for the 12Cr steel based on the data in the wide range of water leak rates. (author)

  9. Metapopulation responses to patch connectivity and quality are masked by successional habitat dynamics.

    Science.gov (United States)

    Hodgson, Jenny A; Moilanen, Atte; Thomas, Chris D

    2009-06-01

    Many species have to track changes in the spatial distribution of suitable habitat from generation to generation. Understanding the dynamics of such species will likely require spatially explicit models, and patch-based metapopulation models are potentially appropriate. However, relatively little attention has been paid to developing metapopulation models that include habitat dynamics, and very little to testing the predictions of these models. We tested three predictions from theory about the differences between dynamic habitat metapopulations and their static counterparts using long-term survey data from two metapopulations of the butterfly Plebejus argus. As predicted, we showed first that the metapopulation inhabiting dynamic habitat had a lower level of habitat occupancy, which could not be accounted for by other differences between the metapopulations. Secondly, we found that patch occupancy did not significantly increase with increasing patch connectivity in dynamic habitat, whereas there was a strong positive connectivity-occupancy relationship in static habitat. Thirdly, we found no significant relationship between patch occupancy and patch quality in dynamic habitat, whereas there was a strong, positive quality-occupancy relationship in static habitat. Modeling confirmed that the differences in mean patch occupancy and connectivity-occupancy slope could arise without changing the species' metapopulation parameters-importantly, without changing the dependence of colonization upon connectivity. We found that, for a range of landscape scenarios, successional simulations always produced a lower connectivity-occupancy slope than comparable simulations with static patches, whether compared like-for-like or controlling for mean occupancy. We conclude that landscape-scale studies may often underestimate the importance of connectivity for species occurrence and persistence because habitat turnover can obscure the connectivity-occupancy relationship in commonly

  10. Using an index of habitat patch proximity for landscape design

    Science.gov (United States)

    Eric J. Gustafson; George R. Parker

    1994-01-01

    A proximity index (PX) inspired by island biogeography theory is described which quantifies the spatial context of a habitat patch in relation to its neighbors. The index distinguishes sparse distributions of small habitat patches from clusters of large patches. An evaluation of the relationship between PX and variation in the spatial characteristics of clusters of...

  11. Babesia microti real-time polymerase chain reaction testing of Connecticut blood donors: potential implications for screening algorithms.

    Science.gov (United States)

    Johnson, Stephanie T; Van Tassell, Eric R; Tonnetti, Laura; Cable, Ritchard G; Berardi, Victor P; Leiby, David A

    2013-11-01

    Babesia microti, an intraerythrocytic parasite, has been implicated in transfusion transmission. B. microti seroprevalence in Connecticut (CT) blood donors is approximately 1%; however, it is not known what percentage of donors is parasitemic and poses a risk for transmitting infection. Therefore, we determined the prevalence of demonstrable B. microti DNA in donors from a highly endemic area of CT and compared observed rates with concurrent immunofluorescence assay (IFA) testing results. Blood samples from consenting donors in southeastern CT were collected from mid-August through early October 2009 and tested by IFA for immunoglobulin G antibodies and real-time polymerase chain reaction (PCR) for B. microti DNA. IFA specificity was determined using blood donor samples collected in northwestern Vermont (VT), an area nonendemic for Babesia. Of 1002 CT donors, 25 (2.5%) were IFA positive and three (0.3%) were real-time PCR positive. Among the three real-time PCR-positive donors, two were also IFA positive, while one was IFA negative and may represent a window period infection. The two IFA- and real-time PCR-positive donors appeared to subsequently clear infection. The other real-time PCR-positive donor did not provide follow-up samples. Of 1015 VT donors tested by IFA, only one (0.1%) was positive, but may have acquired infection during travel to an endemic area. We prospectively identified several real-time PCR-positive blood donors, including an IFA-negative real-time PCR-positive donor, in an area highly endemic for B. microti. These results suggest the need to include nucleic acid testing in planned mitigation strategies for B. microti. © 2013 American Association of Blood Banks.

  12. Non-invasive Pregnancy Diagnosis from Urine by the Cuboni Reaction and the Barium Chloride Test in Donkeys (Equus asinus) and Alpacas (Vicugna pacos).

    Science.gov (United States)

    Kubátová, A; Fedorova, T; Skálová, I; Hyniová, L

    2016-09-01

    The aim of the research was to evaluate two chemical tests for non-invasive pregnancy diagnosis from urine, the Cuboni reaction and the barium chloride test, in donkeys (Equus asinus) and alpacas (Vicugna pacos). The research was carried out from April 2013 to September 2014. Urine samples were collected on five private Czech farms from 18 jennies and 12 alpaca females. Urine was collected non-invasively into plastic cups fastened on a telescopic rod, at 6-9 week intervals. In total, 60 and 54 urine samples from alpacas and jennies, respectively, were collected. The Cuboni reaction was performed by the State Veterinary Institute Prague. The barium chloride test was done with 5 ml of urine mixed together with 5 ml of 1% barium chloride solution. Results of the Cuboni reaction were strongly influenced by the reproductive status of jennies; the test was 100% successful throughout the second half of pregnancy. However, no relationship was found between the real reproductive status of alpaca females and results of the Cuboni reaction. It was concluded that the barium chloride test is not suitable for pregnancy diagnosis either in donkeys, due to significant influence of season on the results, or in alpacas, because no relationship between results of the test and the reproductive status of alpaca females was found. In conclusion, the Cuboni reaction has potential to become a standard pregnancy diagnostic method in donkeys.

  13. Smooth surfaces from rational bilinear patches

    KAUST Repository

    Shi, Ling

    2014-01-01

    Smooth freeform skins from simple panels constitute a challenging topic arising in contemporary architecture. We contribute to this problem area by showing how to approximate a negatively curved surface by smoothly joined rational bilinear patches. The approximation problem is solved with help of a new computational approach to the hyperbolic nets of Huhnen-Venedey and Rörig and optimization algorithms based on it. We also discuss its limits which lie in the topology of the input surface. Finally, freeform deformations based on Darboux transformations are used to generate smooth surfaces from smoothly joined Darboux cyclide patches; in this way we eliminate the restriction to surfaces with negative Gaussian curvature. © 2013 Elsevier B.V.

  14. Super wideband characteristics of monopolar patch antenna

    Directory of Open Access Journals (Sweden)

    Xi Chen

    2013-12-01

    Full Text Available A simple method of acquiring super wideband characteristics for monopolar patch antenna is proposed. Through adopting a modified cone as feeding and radiating structure, the monopolar patch antenna can reach the impedance bandwidth of more than 1:23.4 for voltage standing wave ratio (VSWR ≤ 2. In the whole operating band, the antenna has the like-monopole omnidirectional radiation patterns and the peak gains of 3.8–8.7 dB. Meanwhile, the height of the antenna is just 0.074λ(c, and the diameter of the radiated body is 0.205λ(c, which is smaller than other ultra-wideband omnidirectional antenna.

  15. A Comparative Analysis of Polymerase Chain Reaction and Direct Fluorescent Antibody Test for Diagnosis of Genital Herpes.

    Science.gov (United States)

    Patwardhan, Vrushali; Bhalla, Preena; Rawat, Deepti; Garg, Vijay Kumar; Sardana, Kabir; Sethi, Sumit

    2017-01-01

    To compare laboratory tests that can simultaneously detect and type herpes simplex virus (HSV) directly from the genital ulcer specimens in clinically suspected cases of genital herpes. A study was conducted over 10 months and 44 adult male and female patients clinically suspected with genital herpes were recruited. Genital ulcer swab specimens were subjected to glycoprotein-G gene-based conventional polymerase chain reaction (PCR) and commercially available direct fluorescent antibody (DFA) test and the results were compared. PCR for HSV was positive in 82% (36/44) cases. DFA was positive in 68.2% (30/44) cases. There was 100% agreement between HSV types detected by DFA and PCR. The strength of agreement between the results was better in primary genital herpes than recurrent cases. PCR was found to be better in the detection of HSV in recurrent genital herpes patients. It is a better modality, especially when genital herpes clinically presents with ulcerative or crusted lesions, and is also a cheaper alternative as compared to DFA.

  16. Optimal patch code design via device characterization

    Science.gov (United States)

    Wu, Wencheng; Dalal, Edul N.

    2012-01-01

    In many color measurement applications, such as those for color calibration and profiling, "patch code" has been used successfully for job identification and automation to reduce operator errors. A patch code is similar to a barcode, but is intended primarily for use in measurement devices that cannot read barcodes due to limited spatial resolution, such as spectrophotometers. There is an inherent tradeoff between decoding robustness and the number of code levels available for encoding. Previous methods have attempted to address this tradeoff, but those solutions have been sub-optimal. In this paper, we propose a method to design optimal patch codes via device characterization. The tradeoff between decoding robustness and the number of available code levels is optimized in terms of printing and measurement efforts, and decoding robustness against noises from the printing and measurement devices. Effort is drastically reduced relative to previous methods because print-and-measure is minimized through modeling and the use of existing printer profiles. Decoding robustness is improved by distributing the code levels in CIE Lab space rather than in CMYK space.

  17. A Study on Detection of Elastic Wave Using Patch Type Piezo-Polymer Sensor

    International Nuclear Information System (INIS)

    Kim, Ki Bok; Yoon, Dong Jin; Kueon, Jae Hwa; Lee, Young Seop

    2004-01-01

    Patch type piezo-polymer sensors for smart structures were experimented to detect elastic wave. The pencil lead braking test was performed to analyze the characteristics of patch-type piezo-polymer sensors such as polyvinyliden fluoride (PVDF) and polyvinylidene fluoride trifluorethylene (P(VDF-TrFE)) for several test specimens with various elastic wave velocities and acoustical impedances. The characteristics of the patch-type piezo-polymer sensor were compared with the commercial PZT acoustic emission (AE) sensor. The vacuum grease and epoxy resin were used as a couplant for the acoustic impedance matching between the sensor and specimen. The peak amplitude of elastic wave increased as the diameter of piezo-film and acoustical impedance of the specimen increased. The frequency detection range of the piezo-film sensors decreased with increasing diameter of the piezo-film sensor. The P(VDF-TrFE) sensor was more sensitive than the PVDF sensor

  18. Formulation, in vitro and in vivo evaluation of transdermal patches containing risperidone.

    Science.gov (United States)

    Aggarwal, Geeta; Dhawan, Sanju; Hari Kumar, S L

    2013-01-01

    The efficacy of oral risperidone treatment in prevention of schizophrenia is well known. However, oral side effects and patient compliance is always a problem for schizophrenics. In this study, risperidone was formulated into matrix transdermal patches to overcome these problems. The formulation factors for such patches, including eudragit RL 100 and eudragit RS 100 as matrix forming polymers, olive oil, groundnut oil and jojoba oil in different concentrations as enhancers and amount of drug loaded were investigated. The transdermal patches containing risperidone were prepared by solvent casting method and characterized for physicochemical and in vitro permeation studies through excised rat skin. Among the tested preparations, formulations with 20% risperidone, 3:2 ERL 100 and ERS 100 as polymers, mixture of olive oil and jojoba oil as enhancer, exhibited greatest cumulative amount of drug permeated (1.87 ± 0.09 mg/cm(2)) in 72 h, so batch ROJ was concluded as optimized formulation and assessed for pharmacokinetic, pharmacodynamic and skin irritation potential. The pharmacokinetic characteristics of the optimized risperidone patch were determined using rabbits, while orally administered risperidone in solution was used for comparison. The calculated relative bioavailability of risperidone transdermal patch was 115.20% with prolonged release of drug. Neuroleptic efficacy of transdermal formulation was assessed by rota-rod and grip test in comparison with control and marketed oral formulations with no skin irritation. This suggests the transdermal application of risperidone holds promise for improved bioavailability and better management of schizophrenia in long-term basis.

  19. Modelling of the spallation reaction: analysis and testing of nuclear models; Simulation de la spallation: analyse et test des modeles nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Toccoli, C

    2000-04-03

    The spallation reaction is considered as a 2-step process. First a very quick stage (10{sup -22}, 10{sup -29} s) which corresponds to the individual interaction between the incident projectile and nucleons, this interaction is followed by a series of nucleon-nucleon collisions (intranuclear cascade) during which fast particles are emitted, the nucleus is left in a strongly excited level. Secondly a slower stage (10{sup -18}, 10{sup -19} s) during which the nucleus is expected to de-excite completely. This de-excitation is performed by evaporation of light particles (n, p, d, t, {sup 3}He, {sup 4}He) or/and fission or/and fragmentation. The HETC code has been designed to simulate spallation reactions, this simulation is based on the 2-steps process and on several models of intranuclear cascades (Bertini model, Cugnon model, Helder Duarte model), the evaporation model relies on the statistical theory of Weiskopf-Ewing. The purpose of this work is to evaluate the ability of the HETC code to predict experimental results. A methodology about the comparison of relevant experimental data with results of calculation is presented and a preliminary estimation of the systematic error of the HETC code is proposed. The main problem of cascade models originates in the difficulty of simulating inelastic nucleon-nucleon collisions, the emission of pions is over-estimated and corresponding differential spectra are badly reproduced. The inaccuracy of cascade models has a great impact to determine the excited level of the nucleus at the end of the first step and indirectly on the distribution of final residual nuclei. The test of the evaporation model has shown that the emission of high energy light particles is under-estimated. (A.C.)

  20. Permanent make-up colorants may cause severe skin reactions.

    Science.gov (United States)

    Wenzel, Sabrina M; Welzel, Julia; Hafner, Christian; Landthaler, Michael; Bäumler, Wolfgang

    2010-10-01

    In recent years, cosmetic tattoos [permanent make-up (PMU)] on eyelids, eyebrows and lips have become increasingly popular. However, most colorants are manufactured for non-medical purposes, without any established history of safe use in humans. To investigate severe adverse reactions, such as swelling, burning, and the development of papules, of the lips and the surrounding area in 4 patients who had had at least two PMU procedures on their lips. Adverse skin reactions were examined with patch and prick testing of the colorants. In addition, skin biopsies were taken in the centre of the prick test for histology. One patient declined prick testing. Beauticians tended to use various PMU products, but all contained Pigment Red 181 (CI 73360). All patients tested showed a clear delayed reaction to Pigment Red 181 or the tattoo ink, or both, after prick testing. Histology indicated an allergic reaction. Each lip lesion slowly abated after several months of topical or systemic therapy with steroids in combination with tacrolimus, but none has yet completely resolved. In light of the severe and often therapy-resistant skin reactions, we strongly recommend the regulation and control of the substances used in PMU colorants. © 2010 John Wiley & Sons A/S.