WorldWideScience

Sample records for passive air sampling

  1. Passive sampling of polychlorinated biphenyls (PCB) in indoor air

    DEFF Research Database (Denmark)

    Vorkamp, Katrin; Mayer, Philipp

    PCBs were widely used in construction materials in the 1906s and 1970s, a period of high building activity in Denmark. The objective of this study was therefore to use passive sampling techniques to develop a simple and cost-effective screening tool for PCBs in indoor air. The study proceeded...... in three phases combining a literature review, laboratory experiments and measurements in buildings potentially containing PCBs in indoor air. The laboratory experiments showed a strong influence of air velocity on the PCB partitioning between air and the passive sampler. Based on the results of the first...

  2. Uncertainties in monitoring of SVOCs in air caused by within-sampler degradation during active and passive air sampling

    Science.gov (United States)

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Přibylová, Petra; Vojta, Šimon; Kohoutek, Jiří; Lammel, Gerhard; Klánová, Jana

    2017-10-01

    Degradation of semivolatile organic compounds (SVOCs) occurs naturally in ambient air due to reactions with reactive trace gases (e.g., ozone, NOx). During air sampling there is also the possibility for degradation of SVOCs within the air sampler, leading to underestimates of ambient air concentrations. We investigated the possibility of this sampling artifact in commonly used active and passive air samplers for seven classes of SVOCs, including persistent organic pollutants (POPs) typically covered by air monitoring programs, as well as SVOCs of emerging concern. Two active air samplers were used, one equipped with an ozone denuder and one without, to compare relative differences in mass of collected compounds. Two sets of passive samplers were also deployed to determine the influence of degradation during longer deployment times in passive sampling. In active air samplers, comparison of the two sampling configurations suggested degradation of particle-bound polycyclic aromatic hydrocarbons (PAHs), with concentrations up to 2× higher in the denuder-equipped sampler, while halogenated POPs did not have clear evidence of degradation. In contrast, more polar, reactive compounds (e.g., organophosphate esters and current use pesticides) had evidence of losses in the sampler with denuder. This may be caused by the denuder itself, suggesting sampling bias for these compounds can be created when typical air sampling apparatuses are adapted to limit degradation. Passive air samplers recorded up to 4× higher concentrations when deployed for shorter consecutive sampling periods, suggesting that within-sampler degradation may also be relevant in passive air monitoring programs.

  3. Dispersion modeling of selected PAHs in urban air: A new approach combining dispersion model with GIS and passive air sampling

    Czech Academy of Sciences Publication Activity Database

    Sáňka, O.; Melymuk, L.; Čupr, P.; Dvorská, Alice; Klánová, J.

    2014-01-01

    Roč. 90, oct (2014), s. 88-95 ISSN 1352-2310 Institutional support: RVO:67179843 Keywords : passive air sampling * air dispersion modeling * GIS * polycyclic aromatic hydrocarbons * emission inventories Subject RIV: DI - Air Pollution ; Quality Impact factor: 3.281, year: 2014

  4. Passive air sampling for persistent organic pollutants: Introductory remarks to the special issue

    International Nuclear Information System (INIS)

    Harner, Tom; Bartkow, Michael; Holoubek, Ivan; Klanova, Jana; Wania, Frank; Gioia, Rosalinda; Moeckel, Claudia; Sweetman, Andrew J.; Jones, Kevin C.

    2006-01-01

    There have been a number of developments in the need, design and use of passive air samplers (PAS) for persistent organic pollutants (POPs). This article is the first in a Special Issue of the journal to review these developments and some of the data arising from them. We explain the need and benefit of developing PAS for POPs, the different approaches that can be used, and highlight future developments and needs. - The context, needs and state-of-the-art of passive air sampling techniques for atmospheric persistent organic pollutants are discussed

  5. Comparison of Passive and Active Air Sampling (PAAS) Methods for PCBs – A Pilot Study in New York City Schools

    Science.gov (United States)

    PCBs were used extensively in school building materials (caulk and lighting fixture ballasts) during the approximate period of 1950-1978. Most of the schools built nationwide during this period have not had indoor air sampling conducted for PCBs. Passive air sampling holds promi...

  6. Passive air sampling of polychlorinated biphenyls, organochlorine compounds, and polybrominated diphenyl ethers across Asia.

    Science.gov (United States)

    Jaward, Foday M; Zhang, Gan; Nam, Jae Jak; Sweetman, Andrew J; Obbard, Jeffrey P; Kobara, Yuso; Jones, Kevin C

    2005-11-15

    Asia is of global importance economically, yet data on ambient persistent organic pollutant levels are still sparse for the region, despite international efforts under the Stockholm Convention to identify and reduce emissions. A large-scale passive air sampling survey was therefore conducted in Asia, specifically in China, Japan, South Korea, and Singapore. Polyurethane foam disks were deployed simultaneously at 77 sites, between Sept 21 and Nov 16, 2004, and analyzed for polychlorinated biphenyls (PCBs), organochlorine compounds (hexachlorobenzene (HCB), dichlorodiphenyltrichloroethanes (DDTs), chlordane), and polybrominated diphenyl ethers (PBDEs). The meteorological conditions prevailing in the region at this time facilitated the assessment of local/regional differences in atmospheric emissions, because large-scale advection effects due to monsoons or dust storms did not occur. Air concentrations estimated assuming an average sampler uptake rate of 3.5 m3/day ranged as follows (pg m(-3)): PCBs, 5-340; HCB, 10-460; DDTs, 0.4-1800; chlordanes, 1-660; PBDEs, < 0.13-340. South Korea and Singapore generally had regionally low concentrations. Elevated concentrations of PCBs, DDTs, and HCB occurred at sites in China, higher than reported in a similar recent sampling campaign in Europe. Chlordane was highest in samples from Japan (which also had elevated levels of PCBs and DDTs) and was also elevated in some Chinese locations. PBDE levels were generally low in the region.

  7. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres.

    Science.gov (United States)

    Napoli, Christian; Marcotrigiano, Vincenzo; Montagna, Maria Teresa

    2012-08-02

    Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC) was evaluated at rest (in the morning before the beginning of surgical activity) and in operational (during surgery). The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256) and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7) for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information.

  8. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres

    Directory of Open Access Journals (Sweden)

    Napoli Christian

    2012-08-01

    Full Text Available Abstract Background Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. Methods The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC was evaluated at rest (in the morning before the beginning of surgical activity and in operational (during surgery. Results The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256 and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7 for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. Conclusion It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information.

  9. Evaluation of a passive sampling system of CPVC for nitrogen dioxide in the air

    International Nuclear Information System (INIS)

    Rojas-Bolanos, Omar; Jimenez-Barrantes, Irene

    2012-01-01

    Passive diffusion tubes have been built to determine the concentration of NO 2 in the air with poly tubes (vinyl chloride) chloride (CPVC). The performance has been evaluated during the 2008, through comparisons of their results with the results obtained, using the method modified Griess-Saltzman, recommended by the World Health Organization. The comparison results have shown good agreement between the two methodologies with respect to NO 2 concentrations of 45-85 μg/m''3. Linear regression when used by minimum simple square and ranges test and Wilcoxon signs, no significant differences found between the results provided by both methods. Relative bias calculated in 7 comparisons has varied from -19,05% to 24,44% with an average of 5,76%. The results have indicated that the passive tubes overestimated the concentration of NO 2 ; without however, this bias has not been higher than those reported by other authors. The precision the passive system has been in the field of 5,2% to 10,6%, measured in four tubes through the coefficient of variation, similar to reported by other researchers. (author) [es

  10. Passive air sampling of organochlorine pesticides in a northeastern state of India, Manipur

    Institute of Scientific and Technical Information of China (English)

    Ningombam Linthoingambi Devi; Shihua Qi; Paromita Chakraborty; Gan Zhang; Ishwar Chandra Yadav

    2011-01-01

    Thirty-six polyurethane foam disk passive air samplers (PUF-PAS) were deployed over a year during January to December, 2009 at three locations, i.e., Imphal (urban site), Thoubal (rural site) and Waithou (alpine site) of Manipur, to assess the seasonal local atrnospheric emission of selected organochlorine pesticides (OCPs).The average concentration of HCHs monitored at mountain site during hot season (Mar, Apr, and May) and rainy seasons (Jun, Jul, Aug, and Sep) were 403 and 349 pg/m3, respectively.DDTs had a high concentration with 384 pg/m3 at rural site and 379 pg/m3 at urban site during hot seasons.Endosulfans and chlordane were found high in concentration during hot seasons (260 pg/m3) and low during retreating monsoon seasons (44 pg/m3) at rural site.Most of the OCPs concentrations were high during cultivation period.The OCP concentrations of rainy season were highly correlated (p < 0.01) with OCPs of hot seasons.Further, positive correlation (p < 0.05) was also obtained between cold seasons and retreating monsoon.Principal component analysis showed a significant correlation among the four seasons and distribution pattern of OCPs in air.Back trajectory analysis by using HYPSLIT model showed a long range air transport of OCPs to the present study area.Present OCP levels at Manipur is an outcome of both local emission and also movement of air mass by long range atmospheric transport.

  11. Comparison of dioxin-like PCBs in passive air and vegetation samples surrounding a metal reclamation incinerator

    Energy Technology Data Exchange (ETDEWEB)

    Lucaciu, C.M.; Fayez, L.; Reiner, E.J.; Kolic, T.M.; MacPherson, K.A.; Crozier, P.W.; Emerson, R. [Ontario Ministry of the Environment, Toronto, ON (Canada); Wania, F. [Toronto Univ., Scarborough, ON (Canada). Dept. of Physical and Environmental Sciences

    2004-09-15

    In 1998 the WHO identified 12 PCBs to be dioxin-like (DLPCB). This list includes 4 coplanar: 77, 81, 126, 169 and 8 mono-ortho: 105, 114, 118, 123, 156, 157, 167 and 189 congeners. Determination of DLPCBs allows results to be converted into TEQ (toxic equivalent quantity of 2,3,7,8-TCDD) values and enables data comparison at very low (sub ppt (pg/g)) levels. Vegetation and air samples were collected from an area surrounding a metal recovery incinerator in order to assess spatial and temporal trends for DLPCBs stemming from the long term operation of the incinerator. Foliage samples were harvested in September (1999 - 2 sets, 2000 to 2003) from maple and ash trees surrounding the incinerator at varying distances. Mature tree leaves are exposed to atmospheric deposition of PCBs for about 4 months (June to September) and the levels determined in foliage are representative of DLPCBs in the atmosphere surrounding each tree. Additionally, a passive air sampling technique based on the sorption of gaseous pollutants on XAD-2 (a styrene-divinylbenzene co-polymer) resin was used for measuring long-term average gas-phase concentrations in the area surrounding the incinerator. Ten passive samplers were placed adjacent to trees previously sampled for DLPCBs at locations presented in Figure 1. The deployment period, lasting approximately 4 month (June to September 2003), corresponds to the time that mature leaves were present on the adjacent trees. Four other air samplers were placed close to a main highway in Toronto in order to compare the concentration of DLPCB in the urban area with the concentration in the rural area surrounding the incineration facility. Passive air samplers allow the characterization of the gaseous distribution of DLPCBs in the atmosphere. The advantages of using this technique are that it is independent of the atmospheric conditions (winds, precipitation, UV exposure) and can be used for sampling year round. Atmospheric deposition is expected to control

  12. PCDD/PCDF and dl-PCB in the ambient air of a tropical Andean city: passive and active sampling measurements near industrial and vehicular pollution sources.

    Science.gov (United States)

    Cortés, J; González, C M; Morales, L; Abalos, M; Abad, E; Aristizábal, B H

    2014-09-01

    Concentration gradients were observed in gas and particulate phases of PCDD/F originating from industrial and vehicular sources in the densely populated tropical Andean city of Manizales, using passive and active air samplers. Preliminary results suggest greater concentrations of dl-PCB in the mostly gaseous fraction (using quarterly passive samplers) and greater concentrations of PCDD/F in the mostly particle fraction (using daily active samplers). Dioxin-like PCB predominance was associated with the semi-volatility property, which depends on ambient temperature. Slight variations of ambient temperature in Manizales during the sampling period (15°C-27°C) may have triggered higher concentrations in all passive samples. This was the first passive air sampling monitoring of PCDD/F conducted in an urban area of Colombia. Passive sampling revealed that PCDD/F in combination with dioxin-like PCB ranged from 16 WHO-TEQ2005/m(3) near industrial sources to 7 WHO-TEQ2005/m(3) in an intermediate zone-a reduction of 56% over 2.8 km. Active sampling of particulate phase PCDD/F and dl-PCB were analyzed in PM10 samples. PCDD/F combined with dl-PCB ranged from 46 WHO-TEQ2005/m(3) near vehicular sources to 8 WHO-TEQ2005/m(3) in the same intermediate zone, a reduction of 83% over 2.6 km. Toxic equivalent quantities in both PCDD/F and dl-PCB decreased toward an intermediate zone of the city. Variations in congener profiles were consistent with variations expected from nearby sources, such as a secondary metallurgy plant, areas of concentrated vehicular emissions and a municipal solid waste incinerator (MSWI). These variations in congener profile measurements of dioxins and dl-PCBs in passive and active samples can be partly explained by congener variations expected from the various sources. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Passive air sampling of polybrominated diphenyl ethers in New Delhi, Kolkata, Mumbai and Chennai: Levels, homologous profiling and source apportionment.

    Science.gov (United States)

    Chakraborty, Paromita; Zhang, Gan; Cheng, Hairong; Balasubramanian, Prithiviraj; Li, Jun; Jones, Kevin C

    2017-12-01

    Several studies in the recent past reported new sources for industrial persistent organic pollutants (POPs) from metropolitan cities of India. To fill the data gap for atmospheric polybrominated diphenyl ethers (PBDEs), polyurethane foam disk passive air sampling (PUF-PAS) was conducted along urban-suburban-rural transects in four quadrilateral cities viz., New Delhi, Kolkata, Mumbai and Chennai from northern, eastern, western and southern India respectively. Average concentration of Σ 8 PBDEs in pg/m 3 for New Delhi, Kolkata, Mumbai and Chennai were 198, 135, 264 and 144 respectively. We observed a distinct urban > suburban > rural trend for atmospheric PBDEs in Mumbai. Principal component analysis (PCA) attributed three different source types. BDE-47, -99, -100, -153 and -154 loaded in the first component were relatively high in the sites where industrial and informal electronic waste (e-waste) recycling activities were prevalent. Penta congener, BDE-99 and tetra congener, BDE-47 contributed 50%-75% of total PBDEs. Ratio of BDE-47 and -99 in Indian cities reflected the usage of penta formulations like Bromkal -70DE and DE-71 in the commercial and electrical products. PC-2 was loaded with BDE-28 and -35. Percentage of BDE-28 and BDE-35 (>10%) were comparatively much higher than commercial penta products. Abundance of BDE-28 in majority sites can be primarily due to re-emission from surface soil. PC-3 was loaded with BDE-183 and elevated levels were observed mostly in the industrial corridor of Indian cities. BDE-183 was notably high in the urban industrial sites of New Delhi. We suspect this octa-BDE congener resulted from recycling process of plastic products containing octa-BDE formulation used as flame retardants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Development of a comprehensive analytical method for the determination of chlorinated paraffins in spruce needles applied in passive air sampling

    International Nuclear Information System (INIS)

    Iozza, Saverio; Schmid, Peter; Oehme, Michael

    2009-01-01

    Conifer needles are used for the monitoring of atmospheric persistent organic pollutants. The objective of the present study was to develop a method for the detection of airborne chlorinated paraffins (CPs) using spruce needles as a passive sampler. The method is based on liquid extraction of the cuticular wax layer followed by chromatographic fractionation and detection of CPs using two different GCMS techniques. Total CP concentrations (sum of short (SCCP), medium (MCCP) and long chain CPs (LCCP)) were determined by EI-MS/MS. SCCP and MCCP levels as well as congener group patterns (n-alkane chain length, chlorine content) could be evaluated using ECNI-LRMS. For the first time, data on environmental airborne CPs on spruce needles taken within the Monitoring Network in the Alpine Region for Persistent and other Organic Pollutants (MONARPOP) are presented providing evidence that spruce needles are a suitable passive sampling system for the monitoring of atmospheric CPs. - A developed method for chlorinated paraffins (CPs) provided evidence that spruce needles are a suitable passive sampling system for the monitoring of atmospheric CPs.

  15. Passive air sampling of organochlorine pesticides and polychlorinated biphenyls in the Yangtze River Delta, China: Concentrations, distributions, and cancer risk assessment

    International Nuclear Information System (INIS)

    Zhang, Lifei; Dong, Liang; Yang, Wenlong; Zhou, Li; Shi, Shuangxin; Zhang, Xiulan; Niu, Shan; Li, Lingling; Wu, Zhongxiang; Huang, Yeru

    2013-01-01

    The Yangtze River Delta (YRD) has been quickly industrialized and urbanized. Passive air sampling of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) was carried out in the YRD in 2010–2011 to investigate their spatiotemporal distributions and estimate the risk of cancer from their inhalation. Annual concentrations were 151, 168, 18.8, 110, 17.9, and 35.0 pg m −3 for HCB, ∑DDTs, ∑HCHs, ∑chlordane, mirex, and PCBs, respectively. The highest OCP and PCB concentrations were generally detected in the autumn and winter. The average concentrations of OCPs and PCBs for the different site groups followed the order urban ≈ urban–rural transition > rural. The lifetime excess cancer risks from the inhalation of OCPs and PCBs were −6 . The predicted cancer cases per lifetime associated with the inhalation of OCPs and PCBs are 12, 7, and 4 per ten thousand people for urban, urban–rural transition, and rural areas, respectively. Highlights: •Organochlorine pollutants were measured in the air in the Yangtze River Delta area. •Air PCB concentration declined in recent years comparing with previous results. •HCB and DDEs predominated, with the highest values in winter and autumn, respectively. •OCPs and PCBs followed the order: urban ≈ urban–rural transition > rural. -- A detailed study of organochlorine pesticides and polychlorinated biphenyls in air across the Yangtze River Delta area using passive air samplers

  16. The potential effect of differential ambient and deployment chamber temperatures on PRC derived sampling rates with polyurethane foam (PUF) passive air samplers

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, Karen, E-mail: k.kennedy@uq.edu.a [University of Queensland, EnTox (National Research Centre for Environmental Toxicology), 39 Kessels Rd., Coopers Plains QLD 4108 (Australia); Hawker, Darryl W. [Griffith University, School of Environment, Nathan QLD 4111 (Australia); Bartkow, Michael E. [University of Queensland, EnTox (National Research Centre for Environmental Toxicology), 39 Kessels Rd., Coopers Plains QLD 4108 (Australia); Carter, Steve [Queensland Health Forensic and Scientific Services, Coopers Plains QLD 4108 (Australia); Ishikawa, Yukari; Mueller, Jochen F. [University of Queensland, EnTox (National Research Centre for Environmental Toxicology), 39 Kessels Rd., Coopers Plains QLD 4108 (Australia)

    2010-01-15

    Performance reference compound (PRC) derived sampling rates were determined for polyurethane foam (PUF) passive air samplers in both sub-tropical and temperate locations across Australia. These estimates were on average a factor of 2.7 times higher in summer than winter. The known effects of wind speed and temperature on mass transfer coefficients could not account for this observation. Sampling rates are often derived using ambient temperatures, not the actual temperatures within deployment chambers. If deployment chamber temperatures are in fact higher than ambient temperatures, estimated sampler-air partition coefficients would be greater than actual partition coefficients resulting in an overestimation of PRC derived sampling rates. Sampling rates determined under measured ambient temperatures and estimated deployment chamber temperatures in summer ranged from 7.1 to 10 m{sup 3} day{sup -1} and 2.2-6.8 m{sup 3} day{sup -1} respectively. These results suggest that potential differences between ambient and deployment chamber temperatures should be considered when deriving PRC-based sampling rates. - Internal deployment chamber temperatures rather than ambient temperatures may be required to accurately estimate PRC-based sampling rates.

  17. Variation in isotopologues of atmospheric nitric acid in passively collected samples along an air pollution gradient in southern California

    Science.gov (United States)

    Michael D. Bell; James O. Sickman; Andrzej Bytnerowicz; Pamela E. Padgett; Edith B. Allen

    2014-01-01

    The sources and oxidation pathways of atmospheric nitric acid (HNO3) can be evaluated using the isotopic signatures of oxygen (O) and nitrogen (N). This study evaluated the ability of Nylasorb nylon filters to passively collect unbiased isotopologues of atmospheric HNO3 under controlled and field conditions. Filters...

  18. Gaseous and Freely-Dissolved PCBs in the Lower Great Lakes Based on Passive Sampling: Spatial Trends and Air-Water Exchange.

    Science.gov (United States)

    Liu, Ying; Wang, Siyao; McDonough, Carrie A; Khairy, Mohammed; Muir, Derek C G; Helm, Paul A; Lohmann, Rainer

    2016-05-17

    Polyethylene passive sampling was performed to quantify gaseous and freely dissolved polychlorinated biphenyls (PCBs) in the air and water of Lakes Erie and Ontario during 2011-2012. In view of differing physical characteristics and the impacts of historical contamination by PCBs within these lakes, spatial variation of PCB concentrations and air-water exchange across these lakes may be expected. Both lakes displayed statistically similar aqueous and atmospheric PCB concentrations. Total aqueous concentrations of 29 PCBs ranged from 1.5 pg L(-1) in the open lake of Lake Erie (site E02) in 2011 spring to 105 pg L(-1) in Niagara (site On05) in 2012 summer, while total atmospheric concentrations were 7.7-634 pg m(-3) across both lakes. A west-to-east gradient was observed for aqueous PCBs in Lake Erie. River discharge and localized influences (e.g., sediment resuspension and regional alongshore transport) likely dominated spatial trends of aqueous PCBs in both lakes. Air-water exchange fluxes of Σ7PCBs ranged from -2.4 (±1.9) ng m(-2) day(-1) (deposition) in Sheffield (site E03) to 9.0 (±3.1) ng m(-2) day(-1) (volatilization) in Niagara (site On05). Net volatilization of PCBs was the primary trend across most sites and periods. Almost half of variation in air-water exchange fluxes was attributed to the difference in aqueous concentrations of PCBs. Uncertainty analysis in fugacity ratios and mass fluxes in air-water exchange of PCBs indicated that PCBs have reached or approached equilibrium only at the eastern Lake Erie and along the Canadian shore of Lake Ontario sites, where air-water exchange fluxes dominated atmospheric concentrations.

  19. Decision Support on Small size Passive Samples

    Directory of Open Access Journals (Sweden)

    Vladimir Popukaylo

    2018-05-01

    Full Text Available A construction technique of adequate mathematical models for small size passive samples, in conditions when classical probabilistic-statis\\-tical methods do not allow obtaining valid conclusions was developed.

  20. Passive air sampling of persistent organic pollutants (POPs) and emerging compounds in Kolkata megacity and rural mangrove wetland Sundarban in India: An approach to regional monitoring.

    Science.gov (United States)

    Pozo, Karla; Sarkar, Santosh Kumar; Estellano, Victor H; Mitra, Soumita; Audi, Ondrej; Kukucka, Petr; Přibylová, Petra; Klánová, Jana; Corsolini, Simonetta

    2017-02-01

    Polyurethane foam (PUF) disk passive air samplers were deployed concurrently at five sites across Kolkata megacity and the rural mangrove wetland of Sundarban (UNESCO World Heritage Site) between January-March in 2014. Samples were analyzed for hexachlorocyclohexanes (HCHs), dichlorodiphenyltricholoroethanes (DDTs), polychlorinated biphenyls (PCBs) and, polybrominated diphenyl ethers (PBDEs) using gas chromatography and mass spectrometry (GC-MS). Derived air concentrations (pg/m 3 ) for Kolkata ranged: for ∑α- and γ-HCH between 70 and 207 (114 ± 62), ∑ 6 DDTs: 127-216 (161 ± 36), ∑ 7 PCBs: 53-213 (141 ± 64), and ∑ 10 PBDEs: 0.30-23 (11 ± 9). Low values for all the studied POPs were recorded in the remote area of the Sundarban site (with the exception of DDTs: o,p'-DDT and p,p'-DDT), where ∑ 4 DDTs was 161 ± 36. In particular, the site of Ballygunge, located in the southern part of Kolkata, showed the highest level of all the metabolites/congeners of POPs, suggesting a potential hot spot of usage and emissions. From HCHs, α-/γ-HCH isomers ratio was low (0.67-1.96) indicating a possible sporadic source of lindane. γ-HCH dominated the HCH signal (at 3 sites) reflecting wide spread use of lindane both in Kolkata and the Sundarban region; however, isomeric composition in Kolkata also suggests potential technical HCHs use. Among DDT metabolites, both o,p'-DDT and p,p'-DDT shared the dominant percentages accounting for ∼26-46% of total DDTs followed by p,p'-DDE (∼12-19%). The PCB congener profile was dominated by tri- and tetra-Cl at the southern and eastern part of Kolkata. These results are one of the few contributions that reports air concentrations of POPs, concurrently, at urban and remote villages in India. These data are useful to assess atmospheric pollution levels and to motivate local and regional authorities to better understand the potential human exposure risk associated to urban areas in India. Copyright © 2016 Elsevier Ltd

  1. Environmental monitoring of tritium in air with passive diffusion samplers

    International Nuclear Information System (INIS)

    Wood, M.J.; Workman, W.J.G.

    1992-01-01

    This paper reports on a field trail in which outdoor air was sampled with an active reference sampler and several passive HTO-in-air samplers simultaneously carried out at Chalk River Laboratories. Both passive and active samplers were changed on an approximately monthly schedule from 1990 September 2 to 1991 April 18. Average temperatures for the sampling intervals ranged from -8.06 degrees C to +15.5 degrees C and HTO-in-air concentrations measured by the active sampler were typically 10 Bq/m 3 . A total of 1290 passive HTO-in-air sampler measurements were made during the seven sampling intervals. The passive samplers used for the field trial were prepared with either tritium-free water or a solution of 50% tritium-free water and 50% ethylene glycol. As expected, the samplers prepared with the water-glycol solution performed more consistently than the samplers prepared with water only. Good agreement between passive and active sampler measurements was observed throughout the field trial

  2. Operational air sampling report

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products

  3. Passive sampling methods for contaminated sediments

    DEFF Research Database (Denmark)

    Peijnenburg, Willie J.G.M.; Teasdale, Peter R.; Reible, Danny

    2014-01-01

    “Dissolved” concentrations of contaminants in sediment porewater (Cfree) provide a more relevant exposure metric for risk assessment than do total concentrations. Passive sampling methods (PSMs) for estimating Cfree offer the potential for cost-efficient and accurate in situ characterization...

  4. Radioactive air sampling methods

    CERN Document Server

    Maiello, Mark L

    2010-01-01

    Although the field of radioactive air sampling has matured and evolved over decades, it has lacked a single resource that assimilates technical and background information on its many facets. Edited by experts and with contributions from top practitioners and researchers, Radioactive Air Sampling Methods provides authoritative guidance on measuring airborne radioactivity from industrial, research, and nuclear power operations, as well as naturally occuring radioactivity in the environment. Designed for industrial hygienists, air quality experts, and heath physicists, the book delves into the applied research advancing and transforming practice with improvements to measurement equipment, human dose modeling of inhaled radioactivity, and radiation safety regulations. To present a wide picture of the field, it covers the international and national standards that guide the quality of air sampling measurements and equipment. It discusses emergency response issues, including radioactive fallout and the assets used ...

  5. Emissions databases for polycyclic aromatic compounds in the Canadian Athabasca oil sands region - development using current knowledge and evaluation with passive sampling and air dispersion modelling data

    Science.gov (United States)

    Qiu, Xin; Cheng, Irene; Yang, Fuquan; Horb, Erin; Zhang, Leiming; Harner, Tom

    2018-03-01

    Two speciated and spatially resolved emissions databases for polycyclic aromatic compounds (PACs) in the Athabasca oil sands region (AOSR) were developed. The first database was derived from volatile organic compound (VOC) emissions data provided by the Cumulative Environmental Management Association (CEMA) and the second database was derived from additional data collected within the Joint Canada-Alberta Oil Sands Monitoring (JOSM) program. CALPUFF modelling results for atmospheric polycyclic aromatic hydrocarbons (PAHs), alkylated PAHs, and dibenzothiophenes (DBTs), obtained using each of the emissions databases, are presented and compared with measurements from a passive air monitoring network. The JOSM-derived emissions resulted in better model-measurement agreement in the total PAH concentrations and for most PAH species concentrations compared to results using CEMA-derived emissions. At local sites near oil sands mines, the percent error of the model compared to observations decreased from 30 % using the CEMA-derived emissions to 17 % using the JOSM-derived emissions. The improvement at local sites was likely attributed to the inclusion of updated tailings pond emissions estimated from JOSM activities. In either the CEMA-derived or JOSM-derived emissions scenario, the model underestimated PAH concentrations by a factor of 3 at remote locations. Potential reasons for the disagreement include forest fire emissions, re-emissions of previously deposited PAHs, and long-range transport not considered in the model. Alkylated PAH and DBT concentrations were also significantly underestimated. The CALPUFF model is expected to predict higher concentrations because of the limited chemistry and deposition modelling. Thus the model underestimation of PACs is likely due to gaps in the emissions database for these compounds and uncertainties in the methodology for estimating the emissions. Future work is required that focuses on improving the PAC emissions estimation and

  6. Emissions databases for polycyclic aromatic compounds in the Canadian Athabasca oil sands region – development using current knowledge and evaluation with passive sampling and air dispersion modelling data

    Directory of Open Access Journals (Sweden)

    X. Qiu

    2018-03-01

    Full Text Available Two speciated and spatially resolved emissions databases for polycyclic aromatic compounds (PACs in the Athabasca oil sands region (AOSR were developed. The first database was derived from volatile organic compound (VOC emissions data provided by the Cumulative Environmental Management Association (CEMA and the second database was derived from additional data collected within the Joint Canada–Alberta Oil Sands Monitoring (JOSM program. CALPUFF modelling results for atmospheric polycyclic aromatic hydrocarbons (PAHs, alkylated PAHs, and dibenzothiophenes (DBTs, obtained using each of the emissions databases, are presented and compared with measurements from a passive air monitoring network. The JOSM-derived emissions resulted in better model–measurement agreement in the total PAH concentrations and for most PAH species concentrations compared to results using CEMA-derived emissions. At local sites near oil sands mines, the percent error of the model compared to observations decreased from 30 % using the CEMA-derived emissions to 17 % using the JOSM-derived emissions. The improvement at local sites was likely attributed to the inclusion of updated tailings pond emissions estimated from JOSM activities. In either the CEMA-derived or JOSM-derived emissions scenario, the model underestimated PAH concentrations by a factor of 3 at remote locations. Potential reasons for the disagreement include forest fire emissions, re-emissions of previously deposited PAHs, and long-range transport not considered in the model. Alkylated PAH and DBT concentrations were also significantly underestimated. The CALPUFF model is expected to predict higher concentrations because of the limited chemistry and deposition modelling. Thus the model underestimation of PACs is likely due to gaps in the emissions database for these compounds and uncertainties in the methodology for estimating the emissions. Future work is required that focuses on improving the PAC

  7. Use of passive sampling for atmospheric tritium monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Caldeira Ideias, P.; Pierrard, O.; Tournieux, D. [Institut de Radioprotection et de Surete Nucleaire - IRSN (France); Tenailleau, L. [Marine nationale (France)

    2014-07-01

    Tritium is one of the most important radionuclide in environmental radiological monitoring. In French civil and military nuclear facilities, the releases levels are between 100 to 100 000 higher than any other radionuclide (rare gas excluded). Moreover these levels will probably increase in the next decades. With an average energy of 6 keV, the beta particle from tritium radioactive decay is difficult to detect and quantify within the environmental levels. To monitor the tritium in the air, French actors (authorities, operator, and experts) commonly use atmospheric bubblers and water vapour condensers. This type of sampling approach is time-consuming and very costly. To simplify and complete these methods, the Institute for Radiological Protection and Nuclear Safety (IRSN), had developed an atmospheric tritium monitoring device based on passive sampling. The passive sampler developed consists in a small container designed with a patented specific geometry and filled with 13X molecular sieve. This system is based on free diffusion flow principle (Fick's law). The driving force is the partial pressure gradient existing between the environmental atmosphere and the passive sampler. The constancy of the sampling rate for different moisture conditions assures the representativeness of the proposed device. The desorption bench developed specifically allows the recovery of 99% of the water vapour sampled in the molecular sieve. More than 99% of the sampled tritium (HTO) activity is recovered in the range between 0 and 100 Bq.L{sup -1}. Above 100 Bq.L{sup -1} to 25 k Bq.L{sup -1} (max tested activity), it was verified that no more than 3% of the tritium remains in the molecular sieve.. Thus, the use of passive sampler provides: - a representative sampling method, - a good detection limit (0,01 Bq.m{sup -3}), - no electric power supply needs, - a wide range of sampling duration (1 day to 1 month), - a low-cost method for monitoring. Different performance tests were

  8. Development of More Cost-Effective Methods for Long-Term Monitoring of Soil Vapor Intrusion to Indoor Air Using Quantitative Passive Diffusive-Adsorptive Sampling Techniques

    Science.gov (United States)

    2015-05-01

    ASTM ASTM International ASU Arizona State University ATD automated thermal desorption BENZ Benzene C/Co passive sampler concentration...Protection Agency [USEPA], 1998a, b; California Department of Toxic Substance Control, 2011; ASTM International [ASTM] D7758, 2011). This demonstration... microporous sintered polyethylene, through which the vapors diffuse. Figure 1b. Radiello sampler with regular (white) and low-uptake rate

  9. Air sampling in the workplace

    International Nuclear Information System (INIS)

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC's Regulatory Guide 8.25, Revision 1, ''Air sampling in the Workplace.'' That guide addresses air sampling to meet the requirements in NRC's regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed

  10. A directional passive air sampler for monitoring polycyclic aromatic hydrocarbons (PAHs) in air mass

    International Nuclear Information System (INIS)

    Tao, S.; Liu, Y.N.; Lang, C.; Wang, W.T.; Yuan, H.S.; Zhang, D.Y.; Qiu, W.X.; Liu, J.M.; Liu, Z.G.; Liu, S.Z.; Yi, R.; Ji, M.; Liu, X.X.

    2008-01-01

    A passive air sampler was developed for collecting polycyclic aromatic hydrocarbons (PAHs) in air mass from various directions. The airflow velocity within the sampler was assessed for its responses to ambient wind speed and direction. The sampler was examined for trapped particles, evaluated quantitatively for influence of airflow velocity and temperature on PAH uptake, examined for PAH uptake kinetics, calibrated against active sampling, and finally tested in the field. The airflow volume passing the sampler was linearly proportional to ambient wind speed and sensitive to wind direction. The uptake rate for an individual PAH was a function of airflow velocity, temperature and the octanol-air partitioning coefficient of the PAH. For all PAHs with more than two rings, the passive sampler operated in a linear uptake phase for three weeks. Different PAH concentrations were obtained in air masses from different directions in the field test. - A novel directional passive air sampler was developed and tested for monitoring PAHs in air masses from different directions

  11. Passive sampling for the isotopic fingerprinting of atmospheric mercury

    Science.gov (United States)

    Bergquist, B. A.; MacLagan, D.; Spoznar, N.; Kaplan, R.; Chandan, P.; Stupple, G.; Zimmerman, L.; Wania, F.; Mitchell, C. P. J.; Steffen, A.; Monaci, F.; Derry, L. A.

    2017-12-01

    Recent studies show that there are variations in the mercury (Hg) isotopic signature of atmospheric Hg, which demonstrates the potential for source tracing and improved understanding of atmospheric cycling of Hg. However, current methods for both measuring atmospheric Hg and collecting enough atmospheric Hg for isotopic analyses require expensive instruments that need power and expertise. Additionally, methods for collecting enough atmospheric Hg for isotopic analysis require pumping air through traps for long periods (weeks and longer). Combining a new passive atmospheric sampler for mercury (Hg) with novel Hg isotopic analyses will allow for the application of stable Hg isotopes to atmospheric studies of Hg. Our group has been testing a new passive sampler for gaseous Hg that relies on the diffusion of Hg through a diffusive barrier and adsorption onto a sulphur-impregnated activated carbon sorbent. The benefit of this passive sampler is that it is low cost, requires no power, and collects gaseous Hg for up to one year with linear, well-defined uptake, which allows for reproducible and accurate measurements of atmospheric gaseous Hg concentrations ( 8% uncertainty). As little as one month of sampling is often adequate to collect sufficient Hg for isotopic analysis at typical background concentrations. Experiments comparing the isotopic Hg signature in activated carbon samples using different approaches (i.e. by passive diffusion, by passive diffusion through diffusive barriers of different thickness, by active pumping) and at different temperatures confirm that the sampling process itself does not impose mass-independent fractionation (MIF). However, sampling does result in a consistent and thus correctable mass-dependent fractionation (MDF) effect. Therefore, the sampler preserves Hg MIF with very high accuracy and precision, which is necessary for atmospheric source tracing, and reasonable MDF can be estimated with some increase in error. In addition to

  12. In planta passive sampling devices for assessing subsurface chlorinated solvents.

    Science.gov (United States)

    Shetty, Mikhil K; Limmer, Matt A; Waltermire, Kendra; Morrison, Glenn C; Burken, Joel G

    2014-06-01

    Contaminant concentrations in trees have been used to delineate groundwater contaminant plumes (i.e., phytoscreening); however, variability in tree composition hinders accurate measurement of contaminant concentrations in planta, particularly for long-term monitoring. This study investigated in planta passive sampling devices (PSDs), termed solid phase samplers (SPSs) to be used as a surrogate tree core. Characteristics studied for five materials included material-air partitioning coefficients (Kma) for chlorinated solvents, sampler equilibration time and field suitability. The materials investigated were polydimethylsiloxane (PDMS), low-density polyethylene (LDPE), linear low-density polyethylene (LLDPE), polyoxymethylene (POM) and plasticized polyvinyl chloride (PVC). Both PDMS and LLDPE samplers demonstrated high partitioning coefficients and diffusivities and were further tested in greenhouse experiments and field trials. While most of the materials could be used for passive sampling, the PDMS SPSs performed best as an in planta sampler. Such a sampler was able to accurately measure trichloroethylene (TCE) and tetrachloroethylene (PCE) concentrations while simultaneously incorporating simple operation and minimal impact to the surrounding property and environment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. A survey of perfluoroalkyl sulfonamides in indoor and outdoor air using passive air samplers

    Energy Technology Data Exchange (ETDEWEB)

    Shoeib, M.; Harner, T. [Meteorological Service of Canada, Environment Canada (Canada); Wilford, B.; Jones, K. [Lancaster Univ. (United Kingdom). Environmental Science; Zhu, J. [Chemistry Research Division, Health Canada, Tunney' s Pasture, Ottawa (Canada)

    2004-09-15

    Perfluorooctane sulfonate (PFOS) has recently emerged as a priority environmental pollutant due to its widespread detection in biological samples from remote regions including the Arctic and the Mid-North Pacific Ocean. Because PFOS is fairly involatile, it is hypothesized that its occurrence in remote regions is the result of atmospheric transport of more volatile precursor compounds such as the perfluoroalkyl sulfonamides (PFASs). PFASs are used in variety of consumer products for water and oil resistance including surface treatments for fabric, upholstery, carpet, paper and leather. In a recent pilot study employing high volume air samples, indoor air concentrations of PFASs were approximately 100 times greater than outdoor levels. This is of significance because people typically spend about 90% of their time indoors 5 and this exposure may serve as an important uptake pathway. Indoor air also serves as a source of PFASs to the outside where PFASs are ultimately transported and distributed throughout the environment. The current study is intended to be a more comprehensive survey of indoor and outdoor air allowing more confident conclusions to be made. Passive air samplers comprised of polyurethane foam (PUF) disks were used. These are quiet, non-intrusive samplers that operate without the aid of a pump or electricity. Air movement delivers chemical to the sampler which has a high retention capacity for persistent organic pollutants (POPs). PUF disks samplers have been previously used successfully to monitor different classes of hydrophobic persistent organic pollutants POPs.

  14. Directional dependency of air sampling

    International Nuclear Information System (INIS)

    1994-01-01

    A field study was performed by Idaho State University-Environmental Monitoring Laboratory (EML) to examine the directional dependency of low-volume air samplers. A typical continuous low volume air sampler contains a sample head that is mounted on the sampler housing either horizontally through one of four walls or vertically on an exterior wall 'looking down or up.' In 1992, a field study was undertaken to estimate sampling error and to detect the directional effect of sampler head orientation. Approximately 1/2 mile downwind from a phosphate plant (continuous source of alpha activity), four samplers were positioned in identical orientation alongside one sampler configured with the sample head 'looking down'. At least five consecutive weekly samples were collected. The alpha activity, beta activity, and the Be-7 activity collected on the particulate filter were analyzed to determine sampling error. Four sample heads were than oriented to the four different horizontal directions. Samples were collected for at least five weeks. Analysis of the alpha data can show the effect of sampler orientation to a know near source term. Analysis of the beta and Be-7 activity shows the effect of sampler orientation to a ubiquitous source term

  15. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison

    Science.gov (United States)

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practica...

  16. Sampled Data Systems Passivity and Discrete Port-Hamiltonian Systems

    NARCIS (Netherlands)

    Stramigioli, Stefano; Secchi, Cristian; Schaft, Arjan J. van der; Fantuzzi, Cesare

    2005-01-01

    In this paper, we present a novel way to approach the interconnection of a continuous and a discrete time physical system. This is done in a way which preserves passivity of the coupled system independently of the sampling time T. This strategy can be used both in the field of telemanipulation, for

  17. Accumulation of brevetoxins by passive sampling devices | Shea ...

    African Journals Online (AJOL)

    We report on initial investigations into the use of polymer-based passive sampling devices for the chronic time-integrated measure of brevetoxins in natural waters. Polyethylene membranes readily accumulated brevetoxins, but reached steady state within a few days, likely owing to surface saturation on the polyethylene ...

  18. Calibrating passive sampling and passive dosing techniques to lipid based concentrations

    DEFF Research Database (Denmark)

    Mayer, Philipp; Schmidt, Stine Nørgaard; Annika, A.

    2011-01-01

    Equilibrium sampling into various formats of the silicone polydimethylsiloxane (PDMS) is increasingly used to measure the exposure of hydrophobic organic chemicals in environmental matrices, and passive dosing from silicone is increasingly used to control and maintain their exposure in laboratory...... coated vials and with Head Space Solid Phase Microextraction (HS-SPME) yielded lipid based concentrations that were in good agreement with each other, but about a factor of two higher than measured lipid-normalized concentrations in the organisms. Passive dosing was applied to bioconcentration...

  19. Impacts Of Passive Removal Materials On Indoor Air Quality

    DEFF Research Database (Denmark)

    Darling, Erin; Cros, Clement; Wargocki, Pawel

    2011-01-01

    Indoor air quality (IAQ) was determined in the presence of eight combinations of building materials with and without ozone. Air samples were collected in twin 30 m3 chambers to assess the C5 to C10 aldehyde content of the air while a panel of 18 to 23 human subjects assessed air quality using...... a continuous acceptability scale. Materials were either new carpet that was aired out for three weeks, clay plaster applied to gypsum wallboard that was aired out for up to one month, both materials, or neither. Perceived Air Quality (PAQ) assessed by the panel was most acceptable and concentrations...

  20. Introduction to Maxxam All-Season Passive Sampling System and Principles of Proper Use of Passive Samplers in the Field Study

    Directory of Open Access Journals (Sweden)

    Hongmao Tang

    2001-01-01

    Full Text Available Maxxam all-season passive sampling system (PASS is introduced in this paper. The PASS can be used to quantitatively and accurately monitor SO2 , NO2, O 3, and H2 S in air in all weather conditions with flexible exposure times from several hours to several months. The air pollution detection limits of PASS are very low. They can be from sub ppb to ppt levels. The principles of proper use of passive samplers in the field study are discussed by using the PASS as an example.

  1. Ambient NO2 concentration profiles in Flanders using passive sampling

    Directory of Open Access Journals (Sweden)

    Sanja Potgieter-Vermaak

    2008-09-01

    Full Text Available In most parts of Europe NO2 emissions from excessive road traffic, concentrated by confined spaces and limited dispersion, are often higher than the ambient guideline values. As a pollutant,NO2 has a number of adverse effects on human health and the environment. The European Union sets guideline and threshold values for various pollutants, to protect humans and the environment, of which NO2 is one. Flanders adopted these values as most countries did, and the monitoring and evaluation of the levels against these guideline values are mostly done by VMM (the Flemish Environmental Company. The air quality Framework Directive (96/62/EG was drafted on the27th of September 1996 and instituted on the 21st of November 1996. New guideline values forNO2 will come into effect in 2010 (1999/30/EG. The future hourly guideline value is 200 µg m-3which may not be exceeded more than 18 times in a calendar year. The average annual guideline value must not exceed 40 µg m-3.Currently various pollutants are continuously monitored by means of fixed monster monitors and analysers, where after data is extrapolated to give an overview of the dispersion. In the 2003annual report the future guideline value has been exceeded in 7 locations in Flanders. Moreover, in a separate study it was reported that in various locations with high traffic density and low dispersion, this value was exceeded, even though the dispersion model did not indicate it. Hence, to test these and other locations against the future guideline value a total of 19points, in 6 different cities and towns in Flanders, were chosen to monitor the NO2 profile over a1 year period. Passive sampling, averaged over periods of 2 weeks, was used and comparisons with the fixed monitors in some of these locations were possible. The future annual guideline value of 40 µg m-3 (2010 was exceeded in 11 of the 19 measured locations. When high traffic density was accompanied by low dispersion the value was at its

  2. Passive samplers and community science in regional air quality measurement, education and communication

    International Nuclear Information System (INIS)

    DeForest Hauser, Cindy; Buckley, Alexandra; Porter, Juliana

    2015-01-01

    Charlotte, in Mecklenburg County, North Carolina, was ranked in the top ten cities with the worst air quality for ozone in the United States by the American Lung Association from 2009 to 2011. Nearby counties that may experience similar air quality do not have state or county monitors. This study utilized NO x and ozone Ogawa passive samplers and community scientists to monitor air quality in five counties surrounding Charlotte and increase public engagement in air quality issues. Community scientists deployed samplers weekly at a residential site within each county. Samples were analyzed using spectrophotometry and ion chromatography. Elevated NO x concentrations were observed in four of the five counties relative to those with existing monitors. Ozone concentrations showed little county to county variation, except Iredell and Cabarrus which had higher concentrations than Rowan. Community involvement in this work led to an increase in local dissemination of the results, thus increasing air quality awareness. - Highlights: • NO x concentrations in four adjacent counties were higher than the Mecklenburg site. • Ozone concentrations showed little county to county variation. • Passive samplers and community science can extend the air quality monitoring network. • Community science increases community awareness of air quality issues. - Regional community air quality monitoring is important in educating communities about air quality science issues that can impact personal health and behavior

  3. An economic passive sampling method to detect particulate pollutants using magnetic measurements.

    Science.gov (United States)

    Cao, Liwan; Appel, Erwin; Hu, Shouyun; Ma, Mingming

    2015-10-01

    Identifying particulate matter (PM) emitted from industrial processes into the atmosphere is an important issue in environmental research. This paper presents a passive sampling method using simple artificial samplers that maintains the advantage of bio-monitoring, but overcomes some of its disadvantages. The samplers were tested in a heavily polluted area (Linfen, China) and compared to results from leaf samples. Spatial variations of magnetic susceptibility from artificial passive samplers and leaf samples show very similar patterns. Scanning electron microscopy suggests that the collected PM are mostly in the range of 2-25 μm; frequent occurrence of spherical shape indicates industrial combustion dominates PM emission. Magnetic properties around power plants show different features than other plants. This sampling method provides a suitable and economic tool for semi-quantifying temporal and spatial distribution of air quality; they can be installed in a regular grid and calibrate the weight of PM. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Passive radiative cooling below ambient air temperature under direct sunlight.

    Science.gov (United States)

    Raman, Aaswath P; Anoma, Marc Abou; Zhu, Linxiao; Rephaeli, Eden; Fan, Shanhui

    2014-11-27

    Cooling is a significant end-use of energy globally and a major driver of peak electricity demand. Air conditioning, for example, accounts for nearly fifteen per cent of the primary energy used by buildings in the United States. A passive cooling strategy that cools without any electricity input could therefore have a significant impact on global energy consumption. To achieve cooling one needs to be able to reach and maintain a temperature below that of the ambient air. At night, passive cooling below ambient air temperature has been demonstrated using a technique known as radiative cooling, in which a device exposed to the sky is used to radiate heat to outer space through a transparency window in the atmosphere between 8 and 13 micrometres. Peak cooling demand, however, occurs during the daytime. Daytime radiative cooling to a temperature below ambient of a surface under direct sunlight has not been achieved because sky access during the day results in heating of the radiative cooler by the Sun. Here, we experimentally demonstrate radiative cooling to nearly 5 degrees Celsius below the ambient air temperature under direct sunlight. Using a thermal photonic approach, we introduce an integrated photonic solar reflector and thermal emitter consisting of seven layers of HfO2 and SiO2 that reflects 97 per cent of incident sunlight while emitting strongly and selectively in the atmospheric transparency window. When exposed to direct sunlight exceeding 850 watts per square metre on a rooftop, the photonic radiative cooler cools to 4.9 degrees Celsius below ambient air temperature, and has a cooling power of 40.1 watts per square metre at ambient air temperature. These results demonstrate that a tailored, photonic approach can fundamentally enable new technological possibilities for energy efficiency. Further, the cold darkness of the Universe can be used as a renewable thermodynamic resource, even during the hottest hours of the day.

  5. An experimental investigation of natural circulated air flow in the passive containment cooling system

    International Nuclear Information System (INIS)

    Ryu, S.H.; Oh, S.M.; Park, G.C.

    2004-01-01

    The objective of this study is to investigate the effects of air inlet position and external conditions on the natural circulated air flow rate in a passive containment cooling system of the advanced passive reactor. Experiments have been performed with 1/36 scaled segment type passive containment test facility. The air velocities and temperatures are measured through the air flow path. Also, the experimental results are compared with numerical calculations and show good agreement. (author)

  6. The use of passive samplers for monitoring polycyclic aromatic hydrocarbons in ambient air

    International Nuclear Information System (INIS)

    Jacob, J.; Grimmer, G.; Hildebrandt, A.

    1993-01-01

    In this study polycyclic aromatic hydrocarbon (PAH) concentrations of ambient air are compared to those present in leaves, spruce sprouts and in the corresponding soil used as passive samplers. Marked profile alterations were detected in various soil horizons with increasing relative concentrations of higher boiling and decreasing relative concentrations of lower boiling PAH with depth. There is no direct correlation between the absolute PAH masses found in air samples and those collected by passive samplers or detected in corresponding soil samples. Even the PAH profiles differ significantly: they can, however, be correlated by introducing PAH - and sampler-specific factors. The PAH profiles appear to indicate that coal combustion mostly contributes to the PAH air pollution in the FRG. The time course of the concentration of benzo(a)pyrene and benzo(e)pyrene during the past seven years as measured with spruce sprouts as biological passive sampler indicate a significant decrease of the PAH concentration (by a factor of two) in the FRG. First measurements in a clean air area of the Eastern part of the FRG exhibited up to ten times higher PAH concentrations than found in comparable areas of the western part of the country

  7. Use of passive sampling devices to determine soil contaminant concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K.A. [Clemson Univ., Pendleton, SC (United States)]|[Washington State Univ., Richland, WA (United States); Hooper, M.J. [Clemson Univ., Pendleton, SC (United States); Weisskopf, C.P. [Washington State Univ., Richland, WA (United States)

    1996-12-31

    The effective remediation of contaminated sites requires accurate identification of chemical distributions. A rapid sampling method using passive sampling devices (PSDs) can provide a thorough site assessment. We have been pursuing their application in terrestrial systems and have found that they increase the ease and speed of analysis, decrease solvent usage and overall cost, and minimize the transport of contaminated soils. Time and cost savings allow a higher sampling frequency than is generally the case using traditional methods. PSDs have been used in the field in soils of varying physical properties and have been successful in estimating soil concentrations ranging from 1 {mu}g/kg (parts per billion) to greater than 200 mg/kg (parts per million). They were also helpful in identifying hot spots within the sites. Passive sampling devices show extreme promise as an analytical tool to rapidly characterize contaminant distributions in soil. There are substantial time and cost savings in laboratory personnel and supplies. By selectively excluding common interferences that require sample cleanup, PSDs can be retrieved from the field and processed rapidly (one technician can process approximately 90 PSDs in an 8-h work day). The results of our studies indicate that PSDs can be used to accurately estimate soil contaminant concentrations and provide lower detection limits. Further, time and cost savings will allow a more thorough and detailed characterization of contaminant distributions. 13 refs., 4 figs., 2 tabs.

  8. Passive samplers and community science in regional air quality measurement, education and communication.

    Science.gov (United States)

    DeForest Hauser, Cindy; Buckley, Alexandra; Porter, Juliana

    2015-08-01

    Charlotte, in Mecklenburg County, North Carolina, was ranked in the top ten cities with the worst air quality for ozone in the United States by the American Lung Association from 2009 to 2011. Nearby counties that may experience similar air quality do not have state or county monitors. This study utilized NOx and ozone Ogawa passive samplers and community scientists to monitor air quality in five counties surrounding Charlotte and increase public engagement in air quality issues. Community scientists deployed samplers weekly at a residential site within each county. Samples were analyzed using spectrophotometry and ion chromatography. Elevated NOx concentrations were observed in four of the five counties relative to those with existing monitors. Ozone concentrations showed little county to county variation, except Iredell and Cabarrus which had higher concentrations than Rowan. Community involvement in this work led to an increase in local dissemination of the results, thus increasing air quality awareness. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Verifying Air Force Weather Passive Satellite Derived Cloud Analysis Products

    Science.gov (United States)

    Nobis, T. E.

    2017-12-01

    Air Force Weather (AFW) has developed an hourly World-Wide Merged Cloud Analysis (WWMCA) using imager data from 16 geostationary and polar-orbiting satellites. The analysis product contains information on cloud fraction, height, type and various optical properties including optical depth and integrated water path. All of these products are derived using a suite of algorithms which rely exclusively on passively sensed data from short, mid and long wave imager data. The system integrates satellites with a wide-range of capabilities, from the relatively simple two-channel OLS imager to the 16 channel ABI/AHI to create a seamless global analysis in real time. Over the last couple of years, AFW has started utilizing independent verification data from active sensed cloud measurements to better understand the performance limitations of the WWMCA. Sources utilized include space based lidars (CALIPSO, CATS) and radar (CloudSat) as well as ground based lidars from the Department of Energy ARM sites and several European cloud radars. This work will present findings from our efforts to compare active and passive sensed cloud information including comparison techniques/limitations as well as performance of the passive derived cloud information against the active.

  10. Guidance for air sampling at nuclear facilities

    International Nuclear Information System (INIS)

    Breslin, A.J.

    1976-11-01

    The principal uses of air sampling at nuclear facilities are to monitor general levels of radioactive air contamination, identify sources of air contamination, and evaluate the effectiveness of contaminant control equipment, determine exposures of individual workers, and provide automatic warning of hazardous concentrations of radioactivity. These applications of air sampling are discussed with respect to standards of occupational exposure, instrumentation, sample analysis, sampling protocol, and statistical treatment of concentration data. Emphasis is given to the influence of spacial and temporal variations of radionuclide concentration on the location, duration, and frequency of air sampling

  11. passive and active measurements for some ceramic samples

    International Nuclear Information System (INIS)

    Hassan, M.F.; Said, S.A.; Ali, M.A.; Szegedi, S.

    2004-01-01

    passive measurements for an imported natural ore (zirconium silicate) used in ceramic industries were carried out to identify its radioactivity . this work was done for ceramic quality control purposes. accurate gamma spectrometers with 30% and 70% detector efficiencies were used in the measurements. the 235 U, 238 U and 232 Th radioactivity were determined . for the sake of comparison already manufactured different ceramic samples were investigated applying fast neutrons activation analysis (FNAA) and X-Ray florescence (XRF) techniques. the obtained results were discussed with the tabulated international radioactivity levels for building materials

  12. Field monitoring of volatile organic compounds using passive air samplers in an industrial city in Japan

    International Nuclear Information System (INIS)

    Kume, Kazunari; Ohura, Takeshi; Amagai, Takashi; Fusaya, Masahiro

    2008-01-01

    Highly portable, sensitive, and selective passive air samplers were used to investigate ambient volatile organic compound (VOC) levels at multiple sampling sites in an industrial city, Fuji, Japan. We determined the spatial distributions of 27 species of VOCs in three campaigns: Mar (cold season), May (warm season), and Nov (mild season) of 2004. In all campaigns, toluene (geometric mean concentration, 14.0 μg/m 3 ) was the most abundant VOC, followed by acetaldehyde (4.76 μg/m 3 ), and formaldehyde (2.58 μg/m 3 ). The spatial distributions for certain VOCs showed characteristic patterns: high concentrations of benzene and formaldehyde were typically found along major roads, whereas high concentrations of toluene and tetrachloroethylene (PCE) were usually found near factories. The spatial distribution of PCE observed was extremely consistent with the diffusion pattern calculated from Pollutant Release and Transfer Register data and meteorological data, indicated that passive air samplers are useful for determining the sources and distributions of ambient VOCs. - Passive air samplings with hood are useful for determining the identities, sources, and distributions of ambient VOC pollutants

  13. 40 CFR 61.34 - Air sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air sampling. 61.34 Section 61.34... sampling. (a) Stationary sources subject to § 61.32(b) shall locate air sampling sites in accordance with a... concentrations calculated within 30 days after filters are collected. Records of concentrations at all sampling...

  14. Observations on persistent organic pollutants in indoor and outdoor air using passive polyurethane foam samplers

    Science.gov (United States)

    Bohlin, Pernilla; Jones, Kevin C.; Tovalin, Horacio; Strandberg, Bo

    Air quality data of persistent organic pollutants (POPs) indoors and outdoors are sparse or lacking in several parts of the world, often hampered by the cost and inconvenience of active sampling techniques. Cheap and easy passive air sampling techniques are therefore helpful for reconnaissance surveys. As a part of the Megacity Initiative: Local and Global Research Observations (MILAGRO) project in Mexico City Metropolitan Area in 2006, a range of POPs (polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), and polybrominated diphenyl ethers (PBDEs)) were analyzed in polyurethane foam (PUF) disks used as passive samplers in indoor and outdoor air. Results were compared to those from samplers deployed simultaneously in Gothenburg (Sweden) and Lancaster (United Kingdom). Using sampling rates suggested in the literature, the sums of 13 PAHs in the different sites were estimated to be 6.1-180 ng m -3, with phenanthrene as the predominant compound. Indoor PAH levels tended to be higher in Gothenburg and outdoor levels higher in Mexico City. The sum of PCBs ranged 59-2100 ng m -3, and seemed to be highest indoors in Gothenburg and Lancaster. PBDE levels (sum of seven) ranged 0.68-620 ng m -3, with the highest levels found in some indoor locations. OCPs (i.e. DDTs, HCHs, and chlordanes) were widely dispersed both outdoors and indoors at all three studied areas. In Gothenburg all POPs tended to be higher indoors than outdoors, while indoor and outdoor levels in Mexico City were similar. This could be due to the influence of indoor and outdoor sources, air exchange rates, and lifestyle factors. The study demonstrates how passive samplers can provide quick and cheap reconnaissance data simultaneously at many locations which can shed light on sources and other factors influencing POP levels in air, especially for the gaseous fractions.

  15. Application of Passive Sampling to Characterise the Fish Exometabolome

    Directory of Open Access Journals (Sweden)

    Mark R. Viant

    2017-02-01

    Full Text Available The endogenous metabolites excreted by organisms into their surrounding environment, termed the exometabolome, are important for many processes including chemical communication. In fish biology, such metabolites are also known to be informative markers of physiological status. While metabolomics is increasingly used to investigate the endogenous biochemistry of organisms, no non-targeted studies of the metabolic complexity of fish exometabolomes have been reported to date. In environmental chemistry, Chemcatcher® (Portsmouth, UK passive samplers have been developed to sample for micro-pollutants in water. Given the importance of the fish exometabolome, we sought to evaluate the capability of Chemcatcher® samplers to capture a broad spectrum of endogenous metabolites excreted by fish and to measure these using non-targeted direct infusion mass spectrometry metabolomics. The capabilities of C18 and styrene divinylbenzene reversed-phase sulfonated (SDB-RPS Empore™ disks for capturing non-polar and polar metabolites, respectively, were compared. Furthermore, we investigated real, complex metabolite mixtures excreted from two model fish species, rainbow trout (Oncorhynchus mykiss and three-spined stickleback (Gasterosteus aculeatus. In total, 344 biological samples and 28 QC samples were analysed, revealing 646 and 215 m/z peaks from trout and stickleback, respectively. The measured exometabolomes were principally affected by the type of Empore™ (Hemel Hempstead, UK disk and also by the sampling time. Many peaks were putatively annotated, including several bile acids (e.g., chenodeoxycholate, taurocholate, glycocholate, glycolithocholate, glycochenodeoxycholate, glycodeoxycholate. Collectively these observations show the ability of Chemcatcher® passive samplers to capture endogenous metabolites excreted from fish.

  16. Monitoring of BTX by passive sampling in Hat Yai

    Directory of Open Access Journals (Sweden)

    Proespichaya Kanatharana

    2004-02-01

    Full Text Available Laboratory-built passive samplers were used for monitoring of trace benzene, toluene and xylene (BTX in Hat Yai from 28 July to 12 August, 2003. Sampler bottles contained activated Tenax TA 60/80 meshand a lab-built thermal well were developed and evaluated for the sampling and analysis of BTX. The sampling was carried out for two weeks before the passive samplers were thermally desorbed, trapped ina sampling loop by a laboratory built purge and trap system and analysed by gas chromatography (GC equipped with a flame ionization detector. After optimization and calibration, the developed method showed high selectivity, a good sensitivity with detection limits for BTX of 0.8, 1.1 and 13.0 µg/m3 respectively and an acceptable precision. Ambient BTX measurements were conducted at many monitoring site i.e. hot spots (high exposure, residential areas/work places (common exposure and park (low exposure. The concentration at hot spots range from 3.2 to 5.4 µg/m3 for benzene, 38.0 to 80.3 µg/m3 for toluene and 29.7 to 66.7 µg/m3 for xylene.The low BTX were found at the city periphery (Tesco-Lotus billboard sampling stations, roof level and in Hat Yai Municipal Park but no absolute background concentration could be defined. The monitoring results showed that at higher level from the street surface, the level of BTX tended to decrease and the BTX pollution built up along a street canyon (Sanehanuson Road according to the wind direction. The highest BTX were found at the underground parking, 23.5 725.1 and 267.9 µg/m3 respectively where both WHO guideline for Benzene (16.3 µg/m3 and Toluene (260 µg/m3 were exceeded.

  17. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings.

    Science.gov (United States)

    Beamer, P I; Sugeng, A J; Kelly, M D; Lothrop, N; Klimecki, W; Wilkinson, S T; Loh, M

    2014-05-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites.

  18. First results from the oil sands passive air monitoring network for polycyclic aromatic compounds.

    Science.gov (United States)

    Schuster, Jasmin K; Harner, Tom; Su, Ky; Mihele, Cristian; Eng, Anita

    2015-03-03

    Results are reported from an ongoing passive air monitoring study for polycyclic aromatic compounds (PACs) in the Athabasca oil sands region in Alberta, Canada. Polyurethane foam (PUF) disk passive air samplers were deployed for consecutive 2-month periods from November 2010 to June 2012 at 17 sites. Samples were analyzed for polycyclic aromatic hydrocarbons (PAHs), alkylated PAHs, dibenzothiophene and its alkylated derivatives (DBTs). Relative to parent PAHs, alkylated PAHs and DBTs are enriched in bitumen and therefore considered to be petrogenic markers. Concentrations in air were in the range 0.03-210 ng/m(3), 0.15-230 ng/m(3) and 0.01-61 ng/m(3) for ∑PAHs, ∑alkylated PAHs and ΣDBTs, respectively. An exponential decline of the PAC concentrations in air with distance from mining areas and related petrogenic sources was observed. The most significant exponential declines were for the alkylated PAHs and DBTs and attributed to their association with mining-related emissions and near-source deposition, due to their lower volatility and greater association with depositing particles. Seasonal trends in concentrations in air for PACs were not observed for any of the compound classes. However, a forest fire episode during April to July 2011 resulted in greatly elevated PAH levels at all passive sampling locations. Alkylated PAHs and DBTs were not elevated during the forest fire period, supporting their association with petrogenic sources. Based on the results of this study, an "Athabasca PAC profile" is proposed as a potential source marker for the oil sands region. The profile is characterized by ∑PAHs/∑Alkylated PAHs = ∼0.2 and ∑PAHs/∑DBTs = ∼5.

  19. Evaluation of personal air sampling pumps

    International Nuclear Information System (INIS)

    Ritter, P.D.; Novick, V.J.; Alvarez, J.L.; Huntsman, B.L.

    1987-01-01

    Personal air samplers are used to more conveniently obtain breathing zone samples from individuals over periods of several hours. Personal air sampling pumps must meet minimum performance levels under all working conditions to be suitable for use in radiation protection programs. In addition, the pumps should be simple to operate and as comfortable to wear as possible. Ten models of personal air sampling pumps were tested to evaluate their mechanical performance and physical characteristics. The pumps varied over a wide range in basic performance and operating features. Some of the pumps were found to have adequate performance for use in health physics air sampling applications. 3 references, 2 figures, 5 tables

  20. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison.

    Science.gov (United States)

    Jonker, Michiel T O; van der Heijden, Stephan A; Adelman, Dave; Apell, Jennifer N; Burgess, Robert M; Choi, Yongju; Fernandez, Loretta A; Flavetta, Geanna M; Ghosh, Upal; Gschwend, Philip M; Hale, Sarah E; Jalalizadeh, Mehregan; Khairy, Mohammed; Lampi, Mark A; Lao, Wenjian; Lohmann, Rainer; Lydy, Michael J; Maruya, Keith A; Nutile, Samuel A; Oen, Amy M P; Rakowska, Magdalena I; Reible, Danny; Rusina, Tatsiana P; Smedes, Foppe; Wu, Yanwen

    2018-03-20

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical guidance for standardized passive sampling, and advance the use of passive sampling in regulatory decision making by increasing confidence in the use of the technique. The study was performed by a consortium of 11 laboratories and included experiments with 14 passive sampling formats on 3 sediments for 25 target chemicals (PAHs and PCBs). The resulting overall interlaboratory variability was large (a factor of ∼10), but standardization of methods halved this variability. The remaining variability was primarily due to factors not related to passive sampling itself, i.e., sediment heterogeneity and analytical chemistry. Excluding the latter source of variability, by performing all analyses in one laboratory, showed that passive sampling results can have a high precision and a very low intermethod variability (sampling, irrespective of the specific method used, is fit for implementation in risk assessment and management of contaminated sediments, provided that method setup and performance, as well as chemical analyses are quality-controlled.

  1. Passive sampling and analyses of common dissolved fixed gases in groundwater

    International Nuclear Information System (INIS)

    Spalding, Brian Patrick; Watson, David B.

    2008-01-01

    An in situ passive sampler and gas chromatographic protocol for analysis of the major and several minor fixed gases in groundwater was developed. A gas-tight syringe, mated to a short length of silicone tubing, was equilibrated with dissolved gases in groundwater by immersing in monitoring wells and was used to transport and to inject a 0.5 mL gas sample into a gas chromatograph. Using Ar carrier gas, a HaySep DB porous polymer phase, and sequential thermal conductivity and reductive gas detectors allowed good sensitivity for He, Ne, H2, N2, O2, CO, CH4, CO2, and N2O. Within 4 days of immersion in groundwater, samplers initially filled with either He or air attained the same and constant gas composition at an Oak Ridge, Tennessee, site heavily impacted by uranium, acidity, and nitrate. Between June 2006 and July 2007, 12 permanent groundwater wells were used to test the passive samplers in groundwater contaminated by a group of four closed radioactive wastewater seepage ponds; over a thousand passive gas samples from these wells averaged 56% CO2, 32.4% N2, 2.5% O2, 2.5% N2O, 0.20% CH4, 0.096% H2, and 0.023% CO with an average recovery of 95 14% of the injected gas volume

  2. A critical assessment of passive air samplers for per- and polyfluoroalkyl substances

    Science.gov (United States)

    Karásková, Pavlína; Codling, Garry; Melymuk, Lisa; Klánová, Jana

    2018-07-01

    Since their inclusion in the Stockholm Convention, there has been a need for global monitoring of perfluorooctane sulfonate (PFOS), its salts and perfluorooctanesulfonyl fluoride (PFOSF), along with other non-listed highly fluorinated compounds. Passive air samplers (PAS) are ideal for geographic coverage of atmospheric monitoring. The most common type of PAS, using polyurethane foam (PUF) as a sorbent, was primarily developed for non-polar semivolatile organic compounds (SVOCs) and are not well-validated for polar substances such as the per- and polyfluoroalkyl substances (PFASs), however, they have been used for some PFASs, particularly PFOS. To evaluate their applicability, PAS were deployed for measurement of PFASs in outdoor and indoor air. Outdoors, two types of PAS, one consisting of PUF and one of XAD-2 resin, were deployed in an 18-week calibration study in parallel with a low-volume active air sampler (LV-AAS) in a suburban area. Indoors, PUF-PAS were similarly deployed over 12 weeks to evaluate their applicability for indoor monitoring. Samples were analysed for perfluoroalkyl carboxylic acids (PFCAs), perfluoroalkyl sulfonates (PFSAs), perfluorooctane sulfonamides (FOSAs), and perfluorooctane sulfonamidoethanols (FOSEs). In outdoor air, 17 out of the 21 PFAS were detected in more than 50% of samples, with a median ∑17PFASs of 18.0 pg m-3 while 20 compounds were detected in indoor air with a median concentration ∑20PFASs of 76.6 pg m-3 using AAS samplers. PFOS was the most common PFAS in the outdoor air while PFBA was most common indoors. Variability between PAS and AAS was observed and comparing gas phase and particle phase separately or in combination did not account for the variation observed. PUF-PAS may still have a valuable use in PFAS monitoring but more work is needed to identify the applicability of passive samplers for ionic PFAS.

  3. Strengthening the Network for Monitoring Air Quality in the Valle de Aburra with Passive Meters

    International Nuclear Information System (INIS)

    Zapata S, Carmen; Quijano, Ricardo; Vasquez Eliana

    2008-01-01

    This investigation was made by the National University of Colombia in agreement with the Metropolitan Area of the Aburra Valley. The principal objective was to enforcing the monitoring of the quality of the air of the Aburra valley by means of the passive testers of sulfur dioxide, nitrogen dioxide, ozone, volatile organic compounds (BTX) and the rate of particle sedimentation in main road routes. Testers were settled in 15 Stations of the Metropolitan Area for a year. In gas measurement passive tubes of diffusion were used. Settle able particle measurement uses the principle of the gravity and the samples are analyzed by means of total solids. The results of sulfur dioxide and nitrogen do not exceed the Annual Colombian Norm, but in 12 stations of testing the value is surpassed guides of the WHO for nitrogen dioxide. The ozone levels show formation of this one polluting agent in the zones of slope. In 9 stations the Annual Colombian Norm for benzene is exceeded and all the stations the WHO Norm was not fulfilled. The greater rates of particle sedimentation are obtained in the sites of testing influenced by activities of construction and maintenance of ways. The use of passive measurers allows to identify critic zones and to evaluate of simple way the tendencies of atmospheric contamination. We suggest that in Colombia this technique for the measurement of the quality of the air is approved.

  4. Equivalent Air Spring Suspension Model for Quarter-Passive Model of Passenger Vehicles

    OpenAIRE

    Abid, Haider J.; Chen, Jie; Nassar, Ameen A.

    2015-01-01

    This paper investigates the GENSIS air spring suspension system equivalence to a passive suspension system. The SIMULINK simulation together with the OptiY optimization is used to obtain the air spring suspension model equivalent to passive suspension system, where the car body response difference from both systems with the same road profile inputs is used as the objective function for optimization (OptiY program). The parameters of air spring system such as initial pressure, volume of bag, l...

  5. A passive air sampler for characterizing the vertical concentration profile of gaseous phase polycyclic aromatic hydrocarbons in near soil surface air

    International Nuclear Information System (INIS)

    Zhang Yuzhong; Deng Shuxing; Liu Yanan; Shen Guofeng; Li Xiqing; Cao Jun; Wang Xilong; Reid, Brian; Tao Shu

    2011-01-01

    Air-soil exchange is an important process governing the fate of polycyclic aromatic hydrocarbons (PAHs). A novel passive air sampler was designed and tested for measuring the vertical concentration profile of 4 low molecular weight PAHs in gaseous phase (PAH LMW4 ) in near soil surface air. Air at various heights from 5 to 520 mm above the ground was sampled by polyurethane foam disks held in down-faced cartridges. The samplers were tested at three sites: A: an extremely contaminated site, B: a site near A, and C: a background site on a university campus. Vertical concentration gradients were revealed for PAH LMW4 within a thin layer close to soil surface at the three sites. PAH concentrations either decreased (Site A) or increased (Sites B and C) with height, suggesting either deposition to or evaporation from soils. The sampler is a useful tool for investigating air-soil exchange of gaseous phase semi-volatile organic chemicals. - Research highlights: → Design, field test and calibration of the novel passive air sampler, PAS-V-I. → Vertical concentration gradients of PAH LMW4 within a thin layer close to soil. → Comparison of results between PAS-V-I measurement and fugacity approach. → Potential application of PAS-V-I and further modifications. - A novel passive sampling device was developed and tested for measuring vertical concentration profile of gaseous phase polycyclic aromatic hydrocarbons in near soil surface air.

  6. Evaluation of polyurethane foam passive air sampler (PUF) as a tool for occupational PAH measurements.

    Science.gov (United States)

    Strandberg, Bo; Julander, Anneli; Sjöström, Mattias; Lewné, Marie; Koca Akdeva, Hatice; Bigert, Carolina

    2018-01-01

    Routine monitoring of workplace exposure to polycyclic aromatic hydrocarbons (PAHs) is performed mainly via active sampling. However, active samplers have several drawbacks and, in some cases, may even be unusable. Polyurethane foam (PUF) as personal passive air samplers constitute good alternatives for PAH monitoring in occupational air (8 h). However, PUFs must be further tested to reliably yield detectable levels of PAHs in short exposure times (1-3 h) and under extreme occupational conditions. Therefore, we compared the personal exposure monitoring performance of a passive PUF sampler with that of an active air sampler and determined the corresponding uptake rates (Rs). These rates were then used to estimate the occupational exposure of firefighters and police forensic specialists to 32 PAHs. The work environments studied were heavily contaminated by PAHs with (for example) benzo(a)pyrene ranging from 0.2 to 56 ng m -3 , as measured via active sampling. We show that, even after short exposure times, PUF can reliably accumulate both gaseous and particle-bound PAHs. The Rs-values are almost independent of variables such as the concentration and the wind speed. Therefore, by using the Rs-values (2.0-20 m 3 day -1 ), the air concentrations can be estimated within a factor of two for gaseous PAHs and a factor of 10 for particulate PAHs. With very short sampling times (1 h), our method can serve as a (i) simple and user-friendly semi-quantitative screening tool for estimating and tracking point sources of PAH in micro-environments and (ii) complement to the traditional active pumping methods. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Air sampling with solid phase microextraction

    Science.gov (United States)

    Martos, Perry Anthony

    There is an increasing need for simple yet accurate air sampling methods. The acceptance of new air sampling methods requires compatibility with conventional chromatographic equipment, and the new methods have to be environmentally friendly, simple to use, yet with equal, or better, detection limits, accuracy and precision than standard methods. Solid phase microextraction (SPME) satisfies the conditions for new air sampling methods. Analyte detection limits, accuracy and precision of analysis with SPME are typically better than with any conventional air sampling methods. Yet, air sampling with SPME requires no pumps, solvents, is re-usable, extremely simple to use, is completely compatible with current chromatographic equipment, and requires a small capital investment. The first SPME fiber coating used in this study was poly(dimethylsiloxane) (PDMS), a hydrophobic liquid film, to sample a large range of airborne hydrocarbons such as benzene and octane. Quantification without an external calibration procedure is possible with this coating. Well understood are the physical and chemical properties of this coating, which are quite similar to those of the siloxane stationary phase used in capillary columns. The log of analyte distribution coefficients for PDMS are linearly related to chromatographic retention indices and to the inverse of temperature. Therefore, the actual chromatogram from the analysis of the PDMS air sampler will yield the calibration parameters which are used to quantify unknown airborne analyte concentrations (ppb v to ppm v range). The second fiber coating used in this study was PDMS/divinyl benzene (PDMS/DVB) onto which o-(2,3,4,5,6- pentafluorobenzyl) hydroxylamine (PFBHA) was adsorbed for the on-fiber derivatization of gaseous formaldehyde (ppb v range), with and without external calibration. The oxime formed from the reaction can be detected with conventional gas chromatographic detectors. Typical grab sampling times were as small as 5 seconds

  8. Sampling of BTX in Hat Yai city using cost effective laboratory-built PCB passive sampler.

    Science.gov (United States)

    Subba, Jas Raj; Thammakhet, Chongdee; Thavarungkul, Panote; Kanatharana, Proespichaya

    2016-08-23

    A laboratory-built printed circuit board (PCB) passive sampler used for the monitoring of xylene and styrene in copy print shops was re-validated for detecting benzene, toluene and xylene (BTX) and applied for the sampling of ambient air from Hat Yai city, Songkhla, Thailand, in the month of November 2014. For monitoring, the PCB passive samplers were exposed to target analytes in 16 locations covering high to low exposure areas. After sampling, the samplers were thermally desorbed and the analytes were trapped by multi-walled carbon nanotubes packed into a micro-preconcentrator coupled to a gas chromatograph (GC) equipped with a flame ionization detector. At the optimum GC operating conditions, the linear dynamic ranges for BTX were 0.06-5.6 µg for benzene, 0.07-2.2 µg for toluene and 0.23-2.5 µg for xylene with R(2) > 0.99 with the limits of detection being 6.6, 6.8 and 19 ng for benzene, toluene and xylene, respectively. The concentrations of BTX in the 16 sampling sites were in the range of N.D.-1.3 ± 1.6, 4.50 ± 0.76-49.6 ± 3.7 and 1.00 ± 0.21-39.6 ± 3.1 µg m(-3), respectively. When compared to past studies, there had been an increase in the benzene concentration.

  9. Highly air stable passivation of graphene based field effect devices.

    Science.gov (United States)

    Sagade, Abhay A; Neumaier, Daniel; Schall, Daniel; Otto, Martin; Pesquera, Amaia; Centeno, Alba; Elorza, Amaia Zurutuza; Kurz, Heinrich

    2015-02-28

    The sensitivity of graphene based devices to surface adsorbates and charge traps at the graphene/dielectric interface requires proper device passivation in order to operate them reproducibly under ambient conditions. Here we report on the use of atomic layer deposited aluminum oxide as passivation layer on graphene field effect devices (GFETs). We show that successful passivation produce hysteresis free DC characteristics, low doping level GFETs stable over weeks though operated and stored in ambient atmosphere. This is achieved by selecting proper seed layer prior to deposition of encapsulation layer. The passivated devices are also demonstrated to be robust towards the exposure to chemicals and heat treatments, typically used during device fabrication. Additionally, the passivation of high stability and reproducible characteristics is also shown for functional devices like integrated graphene based inverters.

  10. Passive air sampler as a tool for long-term air pollution monitoring: Part 1. Performance assessment for seasonal and spatial variations

    International Nuclear Information System (INIS)

    Klanova, Jana; Kohoutek, Jiri; Hamplova, Lenka; Urbanova, Petra; Holoubek, Ivan

    2006-01-01

    The potential of passive air sampling devices (polyurethane foam disks) to assess the influence of local sources on the quality of the surrounding environment was investigated. DEZA Valasske Mezirici, a coal tar and mixed tar oils processing plant, and Spolana Neratovice, a chemical factory with the history of high production of organochlorinated pesticides (OCPs), were selected as the point sources of PAHs, and OCPs, respectively. Levels of PCBs, OCPs and PAHs were determined for all sampling sites and sampling periods. The study brought useful data about the air concentrations of POPs in the investigated regions. More important, it provided information on the transport and fate of POPs in the vicinity of local sources of contamination useful for the estimation of their influence. Very good capability of passive samplers to reflect temporal and spatial fluctuation in concentrations of persistent organic pollutants in the ambient air was confirmed which makes them applicable for monitoring on the local scale. - Passive air sampling techniques can indicate seasonal and spatial variations in the ambient concentrations of persistent organic compounds near point sources

  11. Evaluation of a Design Concept for the Combined Air-water Passive Cooling PAFS+

    International Nuclear Information System (INIS)

    Bae, Sung Won; Kwon, Taesoon

    2014-01-01

    The APR+ system provides the Passive Auxiliary Feed-water System (PAFS) for the passive cooling capability. However, the current design requirement for working time for the PAFS is about 8 hours only. Thus, current working time of PAFS can not meet the required 72 hours cooling capability for the long term SBO situation. To meet the 72 hours cooling, the pool capacity should be almost 3∼4 times larger than that of current water cooling tank. In order to continue the PAFS operation for 72 hours, a new passive air-water combined cooling system is proposed. This paper provides the feasibility study on the combined passive air-water cooling system. Figure 1 and 2 show the conceptual difference of the PAFS and combined passive air-water cooling system, respectively. Simple performance evaluation of the passive air cooling heat exchanger has been conducted by the MARS calculation. For the postulated FLB scenario, 4800 heat exchanger tubes and 5 m/s air velocity are not sufficient to sustain the PCCT pool level for 72 hour cooling. Further works on the system design and performance enhancing plan are required to fulfill the 72 hours long term passive cooling

  12. Use of passive sampling devices for monitoring and compliance checking of POP concentrations in water

    NARCIS (Netherlands)

    Lohmann, R.; Booij, K.; Smedes, F.; Vrana, B.

    2012-01-01

    The state of the art of passive water sampling of (nonpolar) organic contaminants is presented. Its suitability for regulatory monitoring is discussed, with an emphasis on the information yielded by passive sampling devices (PSDs), their relevance and associated uncertainties. Almost all persistent

  13. Field calibration of polyurethane foam (PUF) disk passive air samplers for PCBs and OC pesticides.

    Science.gov (United States)

    Chaemfa, Chakra; Barber, Jonathan L; Gocht, Tilman; Harner, Tom; Holoubek, Ivan; Klanova, Jana; Jones, Kevin C

    2008-12-01

    Different passive air sampler (PAS) strategies have been developed for sampling in remote areas and for cost-effective simultaneous spatial mapping of POPs (persistent organic pollutants) over differing geographical scales. The polyurethane foam (PUF) disk-based PAS is probably the most widely used. In a PUF-based PAS, the PUF disk is generally mounted inside two stainless steel bowls to buffer the air flow to the disk and to shield it from precipitation and light. The field study described in this manuscript was conducted to: compare performance of 3 different designs of sampler; to further calibrate the sampler against the conventional active sampler; to derive more information on field-based uptake rates and equilibrium times of the samplers. Samplers were also deployed at different locations across the field site, and at different heights up a meteorological tower, to investigate the possible influence of sampler location. Samplers deployed <5m above ground, and not directly sheltered from the wind gave similar uptake rates. Small differences in dimensions between the 3 designs of passive sampler chamber had no discernable effect on accumulation rates, allowing comparison with previously published data.

  14. Continuous Passive Sampling of Solutes from Agricultural Subsurface Drainage Tubes

    Science.gov (United States)

    Lindblad Vendelboe, Anders; de Jonge, Hubert; Rozemeijer, Joachim; Wollesen de Jonge, Lis

    2015-04-01

    Agricultural subsurface tube drain systems play an important role in water and solute transport. One study, focusing on lowland agricultural catchments, showed that subsurface tube drainage contributed up to 80% of the annual discharge and 90% of the annual NO3 load from agricultural fields to the receiving water bodies. Knowledge of e.g. nutrient loads and drainage volumes, based on measurements and modelling, are important for adequate water quality management. Despite the importance of tube drain transport of solutes, monitoring data are scarce. This scarcity is a result of the existing monitoring techniques for flow and contaminant load from tube drains being expensive and labor-extensive. The study presented here aimed at developing a cheap, simple, and robust method to monitor solute loads from tube drains. The method is based on the newly developed Flowcap, which can be attached to existing tube drain outlets and can measure total flow, contaminant load and flow-averaged concentrations of solutes in the drainage. The Flowcap builds on the existing Sorbicell principle, a passive sampling system that measures average concentrations over longer periods of time (days to months) for various compounds. The Sorbicell consists of two compartments permeable to water. One compartment contains an adsorbent and one contains a tracer. When water passes through the Sorbicell the compound of interest is absorbed while a tracer is released. Using the tracer loss to calculate the volume of water that has passed the Sorbicell it is possible to calculate the average concentration of the compound. When mounting Sorbicells in the Flowcap, a flow-proportional part of the drainage is sampled from the main stream. To accommodate the wide range of drainage flow rates two Flowcaps with different capacities were tested in the laboratory: one with a capacity of 25 L min-1 (Q25) and one with a capacity of 256 L min-1 (Q256). In addition, Sorbicells with two different hydraulic

  15. A holistic passive integrative sampling approach for assessing the presence and potential impacts of waterborne environmental contaminants

    Science.gov (United States)

    Petty, J.D.; Huckins, J.N.; Alvarez, D.A.; Brumbaugh, W. G.; Cranor, W.L.; Gale, R.W.; Rastall, A.C.; Jones-Lepp, T. L.; Leiker, T.J.; Rostad, C. E.; Furlong, E.T.

    2004-01-01

    As an integral part of our continuing research in environmental quality assessment approaches, we have developed a variety of passive integrative sampling devices widely applicable for use in defining the presence and potential impacts of a broad array of contaminants. The semipermeable membrane device has gained widespread use for sampling hydrophobic chemicals from water and air, the polar organic chemical integrative sampler is applicable for sequestering waterborne hydrophilic organic chemicals, the stabilized liquid membrane device is used to integratively sample waterborne ionic metals, and the passive integrative mercury sampler is applicable for sampling vapor phase or dissolved neutral mercury species. This suite of integrative samplers forms the basis for a new passive sampling approach for assessing the presence and potential toxicological significance of a broad spectrum of environmental contaminants. In a proof-of-concept study, three of our four passive integrative samplers were used to assess the presence of a wide variety of contaminants in the waters of a constructed wetland, and to determine the effectiveness of the constructed wetland in removing contaminants. The wetland is used for final polishing of secondary-treatment municipal wastewater and the effluent is used as a source of water for a state wildlife area. Numerous contaminants, including organochlorine pesticides, polycyclic aromatic hydrocarbons, organophosphate pesticides, and pharmaceutical chemicals (e.g., ibuprofen, oxindole, etc.) were detected in the wastewater. Herein we summarize the results of the analysis of the field-deployed samplers and demonstrate the utility of this holistic approach.

  16. Air sampling system for airborne surveys

    International Nuclear Information System (INIS)

    Jupiter, C.; Tipton, W.J.

    1975-01-01

    An air sampling system has been designed for installation on the Beechcraft King Air A-100 aircraft as a part of the Aerial Radiological Measuring System (ARMS). It is intended for both particle and whole gas sampling. The sampling probe is designed for isokinetic sampling and is mounted on a removable modified escape hatch cover, behind the co-pilot's seat, and extends about two feet forward of the hatch cover in the air stream lines. Directly behind the sampling probe inside the modified hatch cover is an expansion chamber, space for a 5-inch diameter filter paper cassette, and an optional four-stage cascade impactor for particle size distribution measurements. A pair of motors and blower pumps provide the necessary 0.5 atmosphere pressure across the type MSA 1106 B glass fiber filter paper to allow a flow rate of 50 cfm. The MSA 1106 B filter paper is designed to trap sub-micrometer particles with a high efficiency; it was chosen to enable a quantitative measurement of airborne radon daughters, one of the principal sources of background signals when radiological surveys are being performed. A venturi section and pressure gauges allow air flow rate measurements so that airborne contaminant concentrations may be quantified. A whole gas sampler capable of sampling a cubic meter of air is mounted inside the aircraft cabin. A nuclear counting system on board the aircraft provides capability for α, β and γ counting of filter paper samples. Design data are presented and types of survey missions which may be served by this system are described

  17. Combination syringe provides air-free blood samples

    Science.gov (United States)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  18. Measurement of Passive Uptake Rates for Volatile Organic Compounds on Commercial Thermal Desorption Tubes and the Effect of Ozone on Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Maddalena, Randy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Parra, Amanda [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Russell, Marion [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lee, Wen-Yee [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-05-01

    Diffusive or passive sampling methods using commercially filled axial-sampling thermal desorption tubes are widely used for measuring volatile organic compounds (VOCs) in air. The passive sampling method provides a robust, cost effective way to measure air quality with time-averaged concentrations spanning up to a week or more. Sampling rates for VOCs can be calculated using tube geometry and Fick’s Law for ideal diffusion behavior or measured experimentally. There is evidence that uptake rates deviate from ideal and may not be constant over time. Therefore, experimentally measured sampling rates are preferred. In this project, a calibration chamber with a continuous stirred tank reactor design and constant VOC source was combined with active sampling to generate a controlled dynamic calibration environment for passive samplers. The chamber air was augmented with a continuous source of 45 VOCs ranging from pentane to diethyl phthalate representing a variety of chemical classes and physiochemical properties. Both passive and active samples were collected on commercially filled Tenax TA thermal desorption tubes over an 11-day period and used to calculate passive sampling rates. A second experiment was designed to determine the impact of ozone on passive sampling by using the calibration chamber to passively load five terpenes on a set of Tenax tubes and then exposing the tubes to different ozone environments with and without ozone scrubbers attached to the tube inlet. During the sampling rate experiment, the measured diffusive uptake was constant for up to seven days for most of the VOCs tested but deviated from linearity for some of the more volatile compounds between seven and eleven days. In the ozone experiment, both exposed and unexposed tubes showed a similar decline in terpene mass over time indicating back diffusion when uncapped tubes were transferred to a clean environment but there was no indication of significant loss by ozone reaction.

  19. Using bioavailability to assess contaminated sediment risk: Passive sampling and Pore Water Remedial Guidelines (PWRGs)

    Science.gov (United States)

    Hosted by the Contaminated Sediment Forum, this half-day course will introduce the RPM to the use of passive samplers to assess bioavailability and in ecological risk assessment. Passive sampling devices (PSD) are a technology with growing acceptance for measuring porewater conce...

  20. Equivalent Air Spring Suspension Model for Quarter-Passive Model of Passenger Vehicles.

    Science.gov (United States)

    Abid, Haider J; Chen, Jie; Nassar, Ameen A

    2015-01-01

    This paper investigates the GENSIS air spring suspension system equivalence to a passive suspension system. The SIMULINK simulation together with the OptiY optimization is used to obtain the air spring suspension model equivalent to passive suspension system, where the car body response difference from both systems with the same road profile inputs is used as the objective function for optimization (OptiY program). The parameters of air spring system such as initial pressure, volume of bag, length of surge pipe, diameter of surge pipe, and volume of reservoir are obtained from optimization. The simulation results show that the air spring suspension equivalent system can produce responses very close to the passive suspension system.

  1. Development of a passive air sampler to measure airborne organophosphorus pesticides and oxygen analogs in an agricultural community.

    Science.gov (United States)

    Armstrong, Jenna L; Yost, Michael G; Fenske, Richard A

    2014-09-01

    Organophosphorus pesticides are some of the most widely used insecticides in the US, and spray drift may result in human exposures. We investigate sampling methodologies using the polyurethane foam passive air sampling device to measure cumulative monthly airborne concentrations of OP pesticides chlorpyrifos, azinphos-methyl, and oxygen analogs. Passive sampling rates (m(3)d(-1)) were determined using calculations using chemical properties, loss of depuration compounds, and calibration with side-by-side active air sampling in a dynamic laboratory exposure chamber and in the field. The effects of temperature, relative humidity, and wind velocity on outdoor sampling rates were examined at 23 sites in Yakima Valley, Washington. Indoor sampling rates were significantly lower than outdoors. Outdoor rates significantly increased with average wind velocity, with high rates (>4m(3)d(-1)) observed above 8ms(-1). In exposure chamber studies, very little oxygen analog was observed on the PUF-PAS, yet substantial amounts chlorpyrifos-oxon and azinphos methyl oxon were measured in outdoor samples. PUF-PAS is a practical and useful alternative to AAS because it results in little artificial transformation to the oxygen analog during sampling, it provides cumulative exposure estimates, and the measured sampling rates were comparable to rates for other SVOCs. It is ideal for community based participatory research due to low subject burden and simple deployment in remote areas. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Passive sampling of pharmaceuticals and personal care products in aquatic environments

    Czech Academy of Sciences Publication Activity Database

    Křesinová, Zdena; Petrů, Klára; Lhotský, O.; Rodsand, T.; Cajthaml, Tomáš

    2016-01-01

    Roč. 6, č. 1 (2016), s. 43-46 ISSN 1805-0174 Institutional support: RVO:61388971 Keywords : passive sampling * polar organic chemical integrative samplers * aquatic matrices Subject RIV: EE - Microbiology, Virology

  3. Passive sampling methods for contaminated sediments: Scientific rationale supporting use of freely dissolved concentrations

    DEFF Research Database (Denmark)

    Mayer, Philipp; Parkerton, Thomas F.; Adams, Rachel G.

    2014-01-01

    Passive sampling methods (PSMs) allow the quantification of the freely dissolved concentration (Cfree ) of an organic contaminant even in complex matrices such as sediments. Cfree is directly related to a contaminant's chemical activity, which drives spontaneous processes including diffusive upta...

  4. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1985-01-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous 85 Kr air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where 85 Kr was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State-of-the-art 85 Dr sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of 85 Kr

  5. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1984-10-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous krypton-85 air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where krypton-85 was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State of the art krypton-85 sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of krypton-85. 3 references, 3 figures, 1 table

  6. Radon discrimination for work place air samples

    International Nuclear Information System (INIS)

    Bratvold, T.

    1994-01-01

    Gross alpha/beta measurement systems are designed solely to identify an incident particle as either an alpha or a beta and register a count accordingly. The tool of choice for radon identification, via decay daughters, is an instrument capable of identifying the energy of incident alpha particles and storing that information separately from detected alpha emissions of different energy. In simpler terms, the desired instrument is an alpha spectroscopy system. K Basins Radiological Control (KBRC) procured an EG ampersand G ORTEC OCTETE PC alpha spectroscopy system to facilitate radon identification on work place air samples. The alpha spectrometer allows for the identification of any alpha emitting isotope based on characteristic alpha emission energies. With this new capability, KBRC will explicitly know whether or not there exists a true airborne concern. Based on historical air quality data, this new information venue will reduce the use of respirators substantially. Situations where an area remains ''on mask'' due solely to the presence of radon daughters on the grab air filter will finally be eliminated. This document serves to introduce a new method for radon daughter detection at the 183KE Health Physics Analytical Laboratory (HPAL). A new work place air sampling analysis program will be described throughout this paper. There is no new technology being introduced, nor any unproven analytical process. The program defined over the expanse of this document simply explains how K Basins Radiological Control will employ their alpha spectrometer

  7. Evaluation and application of a passive air sampler for polycylic aromatic hydrocarbons (PAHs).

    Science.gov (United States)

    Esen, Fatma; Evci, Yildiz M; Tasdemir, Yucel

    2017-08-24

    Sampling of 15 PAHs by the use of both passive air sampler developed (D-PAS) in our research group and PAS (C-PAS) having widespread use in the literature was conducted to compare the performances of the samplers. Sampling was carried out for 1-year period (February 2013-February 2014), in different sampling periods by employing D-PAS and C-PAS. D-PAS and C-PAS were run in parallel for 10, 20, 30, 40 and 60 days. Sampling rates were calculated for both PASs by the use of concentration values obtained from a high-volume air sampler (HVAS). It was determined that calculated sampling values are different from each other by definition of design of C-PAS and D-PAS and difference in environment as velocity of wind and temperature are having different effects upon sampling rates. Collected σ 15 PAHs amounts of 10-day periods in spring, summer, autumn and winter were obtained as 576 ± 333, 209 ± 29, 2402 ± 910 and 664 ± 246 ng for D-PAS and 1070 ± 522, 318 ± 292, 6062 ± 1501 and 6089 ± 4018 ng for C-PAS, respectively. In addition, according to seasons, when collected PAHs in two different samplers were considered, similar results were obtained for the summer time in which no combustion takes place with the aim of domestic heating, while there were differences determined for the seasons with combustion in need of domestic heating. Gas-phase σ 15 PAHs' concentrations were reported depending on seasons in the spring, summer, autumn and winter sequences as 46 ± 32, 9 ± 3, 367 ± 207 and 127 ± 93 ng m -3 for HVAS, respectively.

  8. Passive Badge Assessment for Long-Term, Low-level Air Monitoring on Submarines: Acrolein Badge Validation

    National Research Council Canada - National Science Library

    Williams, Kimberly P; Rose-Pehrsson, Susan L; Kidwell, David A

    2006-01-01

    .... Passive badge monitors for acrolein detection were tested. Long-term sampling efficiency was evaluated for a 28-day period by comparing the response of the passive badge to an active tube sampling method...

  9. Evaluating the precision of passive sampling methods using ...

    Science.gov (United States)

    To assess these models, four different thicknesses of low-density polyethylene (LDPE) passive samplers were co-deployed for 28 days in the water column at three sites in New Bedford Harbor, MA, USA. Each sampler was pre-loaded with six PCB performance reference compounds (PRCs) to assess equilibrium status, such that the percent of PRC lost would range depending on PRC and LDPE thickness. These data allow subsequent Cfree comparisons to be made in two ways: (1) comparing Cfree derived from one thickness using different models and (2) comparing Cfree derived from the same model using different thicknesses of LDPE. Following the deployments, the percent of PRC lost ranged from 0-100%. As expected, fractional equilibrium decreased with increasing PRC molecular weight as well as sampler thickness. Overall, a total of 27 PCBs (log KOW ranging from 5.07 – 8.09) were measured at Cfree concentrations varying from 0.05 pg/L (PCB 206) to about 200 ng/L (PCB 28) on a single LDPE sampler. Relative standard deviations (RSDs) for total PCB measurements using the same thickness and varying model types range from 0.04-12% and increased with sampler thickness. Total PCB RSD for measurements using the same model and varying thickness ranged from: 6 – 30%. No RSD trends between models were observed but RSD did increase as Cfree decreased. These findings indicate that existing models yield precise and reproducible results when using LDPE and PRCs to measure Cfree. This work in

  10. Passive inhalation of marijuana smoke: urinalysis and room air levels of delta-9-tetrahydrocannabinol

    International Nuclear Information System (INIS)

    Cone, E.J.; Johnson, R.E.; Darwin, W.D.; Yousefnejad, D.; Mell, L.D.; Paul, B.D.; Mitchell, J.

    1987-01-01

    In two separate studies, 5 drug-free male volunteers with a history of marijuana use were passively exposed to the sidestream smoke of 4 and 16 marijuana cigarettes (2.8% delta-9-tetrahydrocannabinol [THC]) for 1 h each day for 6 consecutive days. A third study was similarly performed with 2 marijuana-naive subjects passively exposed to the smoke of 16 marijuana cigarettes. Passive smoke exposure was conducted in a small, unventilated room. Room air levels of THC and CO were monitored frequently. All urine specimens were collected and analyzed by EMIT d.a.u. assay, Abuscreen radioimmunoassay and GC/MS. The studies show that significant amounts of THC were absorbed by all subjects at the higher level of passive smoke exposure (eg., smoke from 16 marijuana cigarettes), resulting in urinary excretion of significant amounts of cannabinoid metabolites. However, it seems improbable that subjects would unknowingly tolerate the noxious smoke conditions produced by this exposure. At the lower level of passive marijuana-smoke exposure, specimens tested positive only infrequently or were negative. Room air levels of THC during passive smoke exposure appeared to be the most critical factor in determining whether a subject produced cannabinoid-positive urine specimens

  11. Permeability of gypsum samples dehydrated in air

    Science.gov (United States)

    Milsch, Harald; Priegnitz, Mike; Blöcher, Guido

    2011-09-01

    We report on changes in rock permeability induced by devolatilization reactions using gypsum as a reference analog material. Cylindrical samples of natural alabaster were dehydrated in air (dry) for up to 800 h at ambient pressure and temperatures between 378 and 423 K. Subsequently, the reaction kinetics, so induced changes in porosity, and the concurrent evolution of sample permeability were constrained. Weighing the heated samples in predefined time intervals yielded the reaction progress where the stoichiometric mass balance indicated an ultimate and complete dehydration to anhydrite regardless of temperature. Porosity showed to continuously increase with reaction progress from approximately 2% to 30%, whilst the initial bulk volume remained unchanged. Within these limits permeability significantly increased with porosity by almost three orders of magnitude from approximately 7 × 10-19 m2 to 3 × 10-16 m2. We show that - when mechanical and hydraulic feedbacks can be excluded - permeability, reaction progress, and porosity are related unequivocally.

  12. Estimation of functional failure probability of passive systems based on adaptive importance sampling method

    International Nuclear Information System (INIS)

    Wang Baosheng; Wang Dongqing; Zhang Jianmin; Jiang Jing

    2012-01-01

    In order to estimate the functional failure probability of passive systems, an innovative adaptive importance sampling methodology is presented. In the proposed methodology, information of variables is extracted with some pre-sampling of points in the failure region. An important sampling density is then constructed from the sample distribution in the failure region. Taking the AP1000 passive residual heat removal system as an example, the uncertainties related to the model of a passive system and the numerical values of its input parameters are considered in this paper. And then the probability of functional failure is estimated with the combination of the response surface method and adaptive importance sampling method. The numerical results demonstrate the high computed efficiency and excellent computed accuracy of the methodology compared with traditional probability analysis methods. (authors)

  13. Passive filtration of air egressing from nuclear containment

    Energy Technology Data Exchange (ETDEWEB)

    Malloy, III, John D

    2017-09-26

    A nuclear reactor includes a reactor core comprising fissile material disposed in a reactor pressure vessel. A radiological containment contains the nuclear reactor. A containment compartment contains the radiological containment. A heat sink includes a chimney configured to develop an upward-flowing draft in response to heated fluid flowing into a lower portion of the chimney. A fluid conduit is arranged to receive fluid from the containment compartment and to discharge into the chimney. A filter may be provided, with the fluid conduit including a first fluid conduit arranged to receive fluid from the containment compartment and to discharge into an inlet of the filter, and a second fluid conduit arranged to receive fluid from an outlet of the filter and to discharge into the chimney. As the draft is developed passively, there is no need for a blower or pump configured to move fluid through the fluid conduit.

  14. Passive air conditioning methods for different climates, special ...

    African Journals Online (AJOL)

    One of the most important parameters to be considered in life's style and life's situations of human is the comfort. The usual tools for making thermal comfort are traditional mechanical air conditioners. The disadvantage of them is using much energy and also being dangerous for environment ecological system. Therefore ...

  15. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  16. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  17. Mobile dynamic passive sampling of trace organic compounds: Evaluation of sampler performance in the Danube River.

    Science.gov (United States)

    Vrana, Branislav; Smedes, Foppe; Allan, Ian; Rusina, Tatsiana; Okonski, Krzysztof; Hilscherová, Klára; Novák, Jiří; Tarábek, Peter; Slobodník, Jaroslav

    2018-03-29

    A "dynamic" passive sampling (DPS) device, consisting of an electrically driven large volume water pumping device coupled to a passive sampler exposure cell, was designed to enhance the sampling rate of trace organic compounds. The purpose of enhancing the sampling rate was to achieve sufficient method sensitivity, when the period available for sampling is limited to a few days. Because the uptake principle in the DPS remains the same as for conventionally-deployed passive samplers, free dissolved concentrations can be derived from the compound uptake using available passive sampler calibration parameters. This was confirmed by good agreement between aqueous concentrations of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and hexachlorobenzene (HCB) derived from DPS and conventional caged passive sampler. The DPS device enhanced sampling rates of compounds that are accumulated in samplers under water boundary layer control (WBL) more than five times compared with the conventionally deployed samplers. The DPS device was deployed from a ship cruising downstream the Danube River to provide temporally and spatially integrated concentrations. A DPS-deployed sampler with surface area of 400cm 2 can reach sampling rates up to 83Ld -1 . The comparison of three passive samplers made of different sorbents and co-deployed in the DPS device, namely silicone rubber (SR), low density polyethylene (LDPE) and SDB-RPS Empore™ disks showed a good correlation of surface specific uptake for compounds that were sampled integratively during the entire exposure period. This provided a good basis for a cross-calibration between the samplers. The good correlation of free dissolved PAHs, PCBs and HCB concentration estimates obtained using SR and LDPE confirmed that both samplers are suitable for the identification of concentration gradients and trends in the water column. We showed that the differences in calculated aqueous concentrations between sampler types

  18. Passive Sampling in Regulatory Chemical Monitoring of Nonpolar Organic Compounds in the Aquatic Environment

    DEFF Research Database (Denmark)

    Booij, Kees; Robinson, Craig D; Burgess, Robert M

    2016-01-01

    We reviewed compliance monitoring requirements in the European Union, the United States, and the Oslo-Paris Convention for the protection of the marine environment of the North-East Atlantic, and evaluated if these are met by passive sampling methods for nonpolar compounds. The strengths...... is the best available technology for chemical monitoring of nonpolar organic compounds. Key issues to be addressed by scientists and environmental managers are outlined....... and shortcomings of passive sampling are assessed for water, sediments, and biota. Passive water sampling is a suitable technique for measuring concentrations of freely dissolved compounds. This method yields results that are incompatible with the EU's quality standard definition in terms of total concentrations...

  19. Global evaluation and calibration of a passive air sampler for gaseous mercury

    Science.gov (United States)

    McLagan, David S.; Mitchell, Carl P. J.; Steffen, Alexandra; Hung, Hayley; Shin, Cecilia; Stupple, Geoff W.; Olson, Mark L.; Luke, Winston T.; Kelley, Paul; Howard, Dean; Edwards, Grant C.; Nelson, Peter F.; Xiao, Hang; Sheu, Guey-Rong; Dreyer, Annekatrin; Huang, Haiyong; Hussain, Batual Abdul; Lei, Ying D.; Tavshunsky, Ilana; Wania, Frank

    2018-04-01

    Passive air samplers (PASs) for gaseous mercury (Hg) were deployed for time periods between 1 month and 1 year at 20 sites across the globe with continuous atmospheric Hg monitoring using active Tekran instruments. The purpose was to evaluate the accuracy of the PAS vis-à-vis the industry standard active instruments and to determine a sampling rate (SR; the volume of air stripped of gaseous Hg per unit of time) that is applicable across a wide range of conditions. The sites spanned a wide range of latitudes, altitudes, meteorological conditions, and gaseous Hg concentrations. Precision, based on 378 replicated deployments performed by numerous personnel at multiple sites, is 3.6 ± 3.0 %1, confirming the PAS's excellent reproducibility and ease of use. Using a SR previously determined at a single site, gaseous Hg concentrations derived from the globally distributed PASs deviate from Tekran-based concentrations by 14.2 ± 10 %. A recalibration using the entire new data set yields a slightly higher SR of 0.1354 ± 0.016 m3 day-1. When concentrations are derived from the PAS using this revised SR the difference between concentrations from active and passive sampling is reduced to 8.8 ± 7.5 %. At the mean gaseous Hg concentration across the study sites of 1.54 ng m-3, this represents an ability to resolve concentrations to within 0.13 ng m-3. Adjusting the sampling rate to deployment specific temperatures and wind speeds does not decrease the difference in active-passive concentration further (8.7 ± 5.7 %), but reduces its variability by leading to better agreement in Hg concentrations measured at sites with very high and very low temperatures and very high wind speeds. This value (8.7 ± 5.7 %) represents a conservative assessment of the overall uncertainty of the PAS due to inherent uncertainties of the Tekran instruments. Going forward, the recalibrated SR adjusted for temperature and wind speed should be used, especially if conditions are highly variable or

  20. Global evaluation and calibration of a passive air sampler for gaseous mercury

    Directory of Open Access Journals (Sweden)

    D. S. McLagan

    2018-04-01

    Full Text Available Passive air samplers (PASs for gaseous mercury (Hg were deployed for time periods between 1 month and 1 year at 20 sites across the globe with continuous atmospheric Hg monitoring using active Tekran instruments. The purpose was to evaluate the accuracy of the PAS vis-à-vis the industry standard active instruments and to determine a sampling rate (SR; the volume of air stripped of gaseous Hg per unit of time that is applicable across a wide range of conditions. The sites spanned a wide range of latitudes, altitudes, meteorological conditions, and gaseous Hg concentrations. Precision, based on 378 replicated deployments performed by numerous personnel at multiple sites, is 3.6 ± 3.0 %1, confirming the PAS's excellent reproducibility and ease of use. Using a SR previously determined at a single site, gaseous Hg concentrations derived from the globally distributed PASs deviate from Tekran-based concentrations by 14.2 ± 10 %. A recalibration using the entire new data set yields a slightly higher SR of 0.1354 ± 0.016 m3 day−1. When concentrations are derived from the PAS using this revised SR the difference between concentrations from active and passive sampling is reduced to 8.8 ± 7.5 %. At the mean gaseous Hg concentration across the study sites of 1.54 ng m−3, this represents an ability to resolve concentrations to within 0.13 ng m−3. Adjusting the sampling rate to deployment specific temperatures and wind speeds does not decrease the difference in active–passive concentration further (8.7 ± 5.7 %, but reduces its variability by leading to better agreement in Hg concentrations measured at sites with very high and very low temperatures and very high wind speeds. This value (8.7 ± 5.7 % represents a conservative assessment of the overall uncertainty of the PAS due to inherent uncertainties of the Tekran instruments. Going forward, the recalibrated SR adjusted for temperature and wind speed

  1. A miniature bird-borne passive air sampler for monitoring halogenated flame retardants.

    Science.gov (United States)

    Sorais, Manon; Rezaei, Ali; Okeme, Joseph O; Diamond, Miriam L; Izquierdo, Ricardo; Giroux, Jean-François; Verreault, Jonathan

    2017-12-01

    Birds have been used intensively as biomonitors of halogenated flame retardants (HFRs), and several studies have reported elevated tissue concentrations and inter-individual variability for these contaminants. While diet is known to be an important exposure pathway for HFRs in birds, it has been suggested that exposure through air may represent an underestimated source of HFRs for certain species. However, a method was not available for measuring the atmospheric exposure of individual birds to HFRs or other semi-volatile contaminants. The goal of this study was to develop a bird-borne passive air sampler (PAS) enabling the determination of individual atmospheric exposure to gas- and particle-phase HFRs using the ring-billed gull (Larus delawarensis) nesting in the Montreal area (QC, Canada). The new miniaturized elliptical-shaped PAS (mean weight: 2.72g) was tested using two sorbent types during three exposure periods (one, two and three weeks). Results showed that PAS using polyurethane foam (PUF) combined with a glass fiber filter collected all major polybrominated diphenyl ethers (PBDEs) and exhibited better performance for collecting highly hydrophobic DecaBDE mixture congeners compared to the PAS using polydimethylsiloxane (PDMS). Emerging HFRs including hexabromobenzene, Dechlorane 604 Component B, and Dechlorane plus (DP) isomers also were sampled by the PUF-based PAS. Sampling rates for most HFRs were comparable between the three exposure periods. This novel bird-borne PAS provides valuable information on the non-dietary exposure of free-ranging birds to HFRs. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Passive decay heat removal by natural air convection after severe accidents

    Energy Technology Data Exchange (ETDEWEB)

    Erbacher, F.J.; Neitzel, H.J. [Forschungszentrum Karlsruhe Institut fur Angewandte Thermo- und Fluiddynamik, Karlsruhe (Germany); Cheng, X. [Technische Universitaet Karlsruhe Institut fur Stroemungslehre und Stroemungsmaschinen, Karlsruhe (Germany)

    1995-09-01

    The composite containment proposed by the Research Center Karlsruhe and the Technical University Karlsruhe is to cope with severe accidents. It pursues the goal to restrict the consequences of core meltdown accidents to the reactor plant. One essential of this new containment concept is its potential to remove the decay heat by natural air convection and thermal radiation in a passive way. To investigate the coolability of such a passive cooling system and the physical phenomena involved, experimental investigations are carried out at the PASCO test facility. Additionally, numerical calculations are performed by using different codes. A satisfying agreement between experimental data and numerical results is obtained.

  3. Sampling and identification of gaseous and particle bounded air pollutants

    International Nuclear Information System (INIS)

    Kettrup, A.

    1993-01-01

    Air pollutants are gaseous, components of aerosols or particle bounded. Sampling, sample preparation, identification and quantification of compounds depend from kind and chemical composition of the air pollutants. Quality assurance of analytical data must be guaranted. (orig.) [de

  4. A passive decay heat removal system for LWRs based on air cooling

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyasu, E-mail: mochizki@u-fukui.ac.jp [Research Institute of Nuclear Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan); Yano, Takahiro [Graduate School of Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan)

    2015-05-15

    Highlights: • A passive decay heat removal system for LWRs is discussed. • An air cooler model which condenses steam is developed. • The decay heat can be removed by air coolers with forced convection. • The dimensions of the air cooler are proposed. - Abstract: The present paper describes the capability of an air cooling system (ACS) to remove decay heat from a core of LWR such as an advanced boiling water reactor (ABWR) and a pressurized water reactor (PWR). The motivation of the present research is the Fukushima severe accident (SA) on 11 March 2011. Since emergency cooling systems using electricity were not available due to station blackout (SBO) and malfunctions, many engineers might understand that water cooling was not completely reliable. Therefore, a passive decay heat removal (DHR) system would be proposed in order to prevent such an SA under the conditions of an SBO event. The plant behaviors during the SBO are calculated using the system code NETFLOW++ for the ABWR and PWR with the ACS. Two types of air coolers (ACs) are applied for the ABWR, i.e., a steam condensing air cooler (SCAC) of which intake for heat transfer tubes is provided in the steam region, and single-phase type of which intake is provided in the water region. The DHR characteristics are calculated under the conditions of the forced air circulation and also the natural air convection. As a result of the calculations, the decay heat can be removed safely by the reasonably sized ACS when heat transfer tubes are cooled with the forced air circulation. The heat removal rate per one finned heat transfer tube is evaluated as a function of air flow rate. The heat removal rate increases as a function of the air flow rate.

  5. Velocity dependent passive sampling for monitoring of micropollutants in dynamic stormwater discharges

    DEFF Research Database (Denmark)

    Birch, Heidi; Sharma, Anitha Kumari; Vezzaro, Luca

    2013-01-01

    Micropollutant monitoring in stormwater discharges is challenging because of the diversity of sources and thus large number of pollutants found in stormwater. This is further complicated by the dynamics in runoff flows and the large number of discharge points. Most passive samplers are non......-ideal for sampling such systems because they sample in a time-integrative manner. This paper reports test of a flow-through passive sampler, deployed in stormwater runoff at the outlet of a residential-industrial catchment. Momentum from the water velocity during runoff events created flow through the sampler...... resulting in velocity dependent sampling. This approach enables the integrative sampling of stormwater runoff during periods of weeks to months while weighting actual runoff events higher than no flow periods. Results were comparable to results from volume-proportional samples and results obtained from...

  6. Water sampling at the Berge Helene FPSO at Chinguetti field in Mauritania using passive samplers

    NARCIS (Netherlands)

    Korytar, P.; Galien, van der W.

    2007-01-01

    Three rounds of water sampling were performed at the Berge Helene FPSO at the Chinguetti field in Mauritania using passive samplers attached to the FPSO to determine the levels of contamination that could potentially accumulate in organisms. Two rounds were carried out prior to the commencement of

  7. Using a Ventilation Controller to Optimize Residential Passive Ventilation For Energy and Indoor Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    One way to reduce the energy impact of providing residential ventilation is to use passive and hybrid systems. However, these passive and hybrid (sometimes called mixed-mode) systems must still meet chronic and acute health standards for ventilation. This study uses a computer simulation approach to examine the energy and indoor air quality (IAQ) implications of passive and hybrid ventilation systems, in 16 California climate zones. Both uncontrolled and flow controlled passive stacks are assessed. A new hybrid ventilation system is outlined that uses an intelligent ventilation controller to minimise energy use, while ensuring chronic and acute IAQ standards are met. ASHRAE Standard 62.2-2010 – the United States standard for residential ventilation - is used as the chronic standard, and exposure limits for PM2.5, formaldehyde and NO2 are used as the acute standards.The results show that controlled passive ventilation and hybrid ventilation can be used in homes to provide equivalent IAQ to continuous mechanical ventilation, for less use of energy.

  8. Passive sampling of selected pesticides in aquatic environment using polar organic chemical integrative samplers.

    Science.gov (United States)

    Thomatou, Alphanna-Akrivi; Zacharias, Ierotheos; Hela, Dimitra; Konstantinou, Ioannis

    2011-08-01

    Polar chemical integrative samplers (POCIS) were examined for their sampling efficiency of 12 pesticides and one metabolite commonly detected in surface waters. Laboratory-based calibration experiments of POCISs were conducted. The determined passive sampling rates were applied for the monitoring of pesticides levels in Lake Amvrakia, Western Greece. Spot sampling was also performed for comparison purposes. Calibration experiments were performed on the basis of static renewal exposure of POCIS under stirred conditions for different time periods of up to 28 days. The analytical procedures were based on the coupling of POCIS and solid phase extraction by Oasis HLB cartridges with gas chromatography-mass spectrometry. The recovery of the target pesticides from the POCIS was generally >79% with relative standard deviation (RSD) monitoring campaign using both passive and spot sampling whereas higher concentrations were measured by spot sampling in most cases. Passive sampling by POCIS provides a useful tool for the monitoring of pesticides in aquatic systems since integrative sampling at rates sufficient for analytical quantitation of ambient levels was observed. Calibration data are in demand for a greater number of compounds in order to extend the use in environmental monitoring.

  9. Are passive smoking, air pollution and obesity a greater mortality risk than major radiation incidents?

    Directory of Open Access Journals (Sweden)

    Smith Jim T

    2007-04-01

    Full Text Available Abstract Background Following a nuclear incident, the communication and perception of radiation risk becomes a (perhaps the major public health issue. In response to such incidents it is therefore crucial to communicate radiation health risks in the context of other more common environmental and lifestyle risk factors. This study compares the risk of mortality from past radiation exposures (to people who survived the Hiroshima and Nagasaki atomic bombs and those exposed after the Chernobyl accident with risks arising from air pollution, obesity and passive and active smoking. Methods A comparative assessment of mortality risks from ionising radiation was carried out by estimating radiation risks for realistic exposure scenarios and assessing those risks in comparison with risks from air pollution, obesity and passive and active smoking. Results The mortality risk to populations exposed to radiation from the Chernobyl accident may be no higher than that for other more common risk factors such as air pollution or passive smoking. Radiation exposures experienced by the most exposed group of survivors of Hiroshima and Nagasaki led to an average loss of life expectancy significantly lower than that caused by severe obesity or active smoking. Conclusion Population-averaged risks from exposures following major radiation incidents are clearly significant, but may be no greater than those from other much more common environmental and lifestyle factors. This comparative analysis, whilst highlighting inevitable uncertainties in risk quantification and comparison, helps place the potential consequences of radiation exposures in the context of other public health risks.

  10. Comparison of active and passive sampling strategies for the monitoring of pesticide contamination in streams

    Science.gov (United States)

    Assoumani, Azziz; Margoum, Christelle; Guillemain, Céline; Coquery, Marina

    2014-05-01

    The monitoring of water bodies regarding organic contaminants, and the determination of reliable estimates of concentrations are challenging issues, in particular for the implementation of the Water Framework Directive. Several strategies can be applied to collect water samples for the determination of their contamination level. Grab sampling is fast, easy, and requires little logistical and analytical needs in case of low frequency sampling campaigns. However, this technique lacks of representativeness for streams with high variations of contaminant concentrations, such as pesticides in rivers located in small agricultural watersheds. Increasing the representativeness of this sampling strategy implies greater logistical needs and higher analytical costs. Average automated sampling is therefore a solution as it allows, in a single analysis, the determination of more accurate and more relevant estimates of concentrations. Two types of automatic samplings can be performed: time-related sampling allows the assessment of average concentrations, whereas flow-dependent sampling leads to average flux concentrations. However, the purchase and the maintenance of automatic samplers are quite expensive. Passive sampling has recently been developed as an alternative to grab or average automated sampling, to obtain at lower cost, more realistic estimates of the average concentrations of contaminants in streams. These devices allow the passive accumulation of contaminants from large volumes of water, resulting in ultratrace level detection and smoothed integrative sampling over periods ranging from days to weeks. They allow the determination of time-weighted average (TWA) concentrations of the dissolved fraction of target contaminants, but they need to be calibrated in controlled conditions prior to field applications. In other words, the kinetics of the uptake of the target contaminants into the sampler must be studied in order to determine the corresponding sampling rate

  11. Design and transient analyses of passive emergency feedwater system of CPR1000. Part 1. Air cooling condition

    International Nuclear Information System (INIS)

    Zhang Yapei; Qiu Suizheng; Su Guanghui; Tian Wenxi; Cao Jianhua; Lu Donghua; Fu Xiangang

    2011-01-01

    The steam generator secondary passive emergency feedwater system is a new design for traditional generation Ⅱ + reactor CPR1000. The passive emergency feedwater system is designed to supply water to the SG shell side and improve the safety and reliability of CPR1000 by completely or partially replacing traditional emergency water cooling system in the event of the feed line break (FLB) or loss of heat sink accident. The passive emergency feedwater system consists of steam generator (SG), heat exchanger (HX), air cooling tower, emergency makeup tank (EMT), and corresponding pipes and valves for air cooling condition. In order to improve the safety and reliability of CPR1000, the model of the primary loop system and the passive emergency feedwater system was developed to investigate residual heat removal capability of the passive emergency feedwater system and the transient characteristics of the primary loop system affected by the passive emergency feedwater system using RELAP5/MOD3.4. The transient characteristics of the primary loop system and the passive emergency feedwater system were calculated in the event of feed line break accident. Sensitivity studies of the passive emergency feedwater system were also conducted to investigate the response of the primary loop and the passive emergency feedwater system on the main parameters of the passive emergency feedwater system. The passive emergency feedwater system could supply water to the SG shell side from the EMT successfully. The calculation results showed that the passive emergency feedwater system could take away the decay heat from the primary loop effectively for air cooling condition, and that the single-phase and two-phase natural circulations were established in the primary loop and passive emergency feedwater system loop, respectively. (author)

  12. Highly simplified lateral flow-based nucleic acid sample preparation and passive fluid flow control

    Science.gov (United States)

    Cary, Robert E.

    2015-12-08

    Highly simplified lateral flow chromatographic nucleic acid sample preparation methods, devices, and integrated systems are provided for the efficient concentration of trace samples and the removal of nucleic acid amplification inhibitors. Methods for capturing and reducing inhibitors of nucleic acid amplification reactions, such as humic acid, using polyvinylpyrrolidone treated elements of the lateral flow device are also provided. Further provided are passive fluid control methods and systems for use in lateral flow assays.

  13. Highly simplified lateral flow-based nucleic acid sample preparation and passive fluid flow control

    Energy Technology Data Exchange (ETDEWEB)

    Cary, Robert B.

    2018-04-17

    Highly simplified lateral flow chromatographic nucleic acid sample preparation methods, devices, and integrated systems are provided for the efficient concentration of trace samples and the removal of nucleic acid amplification inhibitors. Methods for capturing and reducing inhibitors of nucleic acid amplification reactions, such as humic acid, using polyvinylpyrrolidone treated elements of the lateral flow device are also provided. Further provided are passive fluid control methods and systems for use in lateral flow assays.

  14. Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments

    Science.gov (United States)

    2015-08-01

    biodegradation . As discussed in Fernandez et al. (2009b), target compounds like PCBs and PAHs diffuse through the surrounding environmental media... biodegradation . The PE passive sampling technique may also offer significant cost savings per site for sample collection and analysis cost. When compared with...water, detergent), Nitrile gloves, aluminum foil, plastic sheeting, rope, paper towels, garbage bags , bubble wrap, Ziplock bags , and ice. • Non

  15. Passive sampling as a tool for identifying micro-organic compounds in groundwater.

    Science.gov (United States)

    Mali, N; Cerar, S; Koroša, A; Auersperger, P

    2017-09-01

    The paper presents the use of a simple and cost efficient passive sampling device with integrated active carbon with which to test the possibility of determining the presence of micro-organic compounds (MOs) in groundwater and identifying the potential source of pollution as well as the seasonal variability of contamination. Advantage of the passive sampler is to cover a long sampling period by integrating the pollutant concentration over time, and the consequently analytical costs over the monitoring period can be reduced substantially. Passive samplers were installed in 15 boreholes in the Maribor City area in Slovenia, with two sampling campaigns covered a period about one year. At all sampling sites in the first series a total of 103 compounds were detected, and 144 in the second series. Of all detected compounds the 53 most frequently detected were selected for further analysis. These were classified into eight groups based on the type of their source: Pesticides, Halogenated solvents, Non-halogenated solvents, Domestic and personal, Plasticizers and additives, Other industrial, Sterols and Natural compounds. The most frequently detected MO compounds in groundwater were tetrachloroethene and trichloroethene from the Halogenated solvents group. The most frequently detected among the compound's groups were pesticides. Analysis of frequency also showed significant differences between the two sampling series, with less frequent detections in the summer series. For the analysis to determine the origin of contamination three groups of compounds were determined according to type of use: agriculture, urban and industry. Frequency of detection indicates mixed land use in the recharge areas of sampling sites, which makes it difficult to specify the dominant origin of the compound. Passive sampling has proved to be useful tool with which to identify MOs in groundwater and for assessing groundwater quality. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Passive Dosing to Determine the Speciation of Hydrophobic Organic Chemicals in Aqueous Samples

    DEFF Research Database (Denmark)

    Birch, Heidi; Gouliarmou, V.; Lützhøft, Hans-Christian Holten

    2010-01-01

    A new analytical approach to determine the speciation of hydrophobic organic analytes is presented. The freely dissolved concentration in a sample is controlled by passive dosing from silicone (poly(dimethylsiloxane)), and the total sample concentration at equilibrium is measured. The free fraction...... is determined as the ratio between measured concentrations in pure water and sample. C-14-labeled fluoranthene served as model analyte, and total sample concentrations were easily measured by liquid scintillation counting. The method was applied to surface water, stormwater runoff, and wastewater...... (SPME). This analytical approach combines simplicity with high precision, and it does not require any phase separation steps....

  17. [Influence of Natural Dissolved Organic Matter on the Passive Sampling Technique and its Application].

    Science.gov (United States)

    Yu, Shang-yun; Zhou, Yan-mei

    2015-08-01

    This paper studied the effects of different concentrations of natural dissolved organic matter (DOM) on the passive sampling technique. The results showed that the presence of DOM affected the organic pollutant adsorption ability of the membrane. For lgK(OW), 3-5, DOM had less impact on the adsorption of organic matter by the membrane; for lgK(OW), > 5.5, DOM significantly increased the adsorption capacity of the membrane. Meanwhile, LDPE passive sampling technique was applied to monitor PAHs and PAEs in pore water of three surface sediments in Taizi River. All of the target pollutants were detected in varying degrees at each sampling point. Finally, the quotient method was used to assess the ecological risks of PAHs and PAEs. The results showed that fluoranthene exceeded the reference value of the aquatic ecosystem, meaning there was a big ecological risk.

  18. Systematic Evaluation of Aggressive Air Sampling for Bacillus ...

    Science.gov (United States)

    Report The primary objectives of this project were to evaluate the Aggressive Air Sampling (AAS) method compared to currently used surface sampling methods and to determine if AAS is a viable option for sampling Bacillus anthracis spores.

  19. Passive sampling of ambient ozone by solid phase microextraction with on-fiber derivatization

    International Nuclear Information System (INIS)

    Lee, I-S.; Tsai, S.-W.

    2008-01-01

    The solid phase microextraction (SPME) device with the polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used as a passive sampler for ambient ozone. Both O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) and 1,2-di-(4-pyridyl)ethylene (DPE) were loaded onto the fiber before sampling. The SPME fiber assembly was then inserted into a PTFE tubing as a passive sampler. Known concentrations of ozone around the ambient ground level were generated by a calibrated ozone generator. Laboratory validations of the SPME passive sampler with the direct-reading ozone monitor were performed side-by-side in an exposure chamber at 25 deg. C. After exposures, pyriden-4-aldehyde was formed due to the reaction between DPE and ozone. Further on-fiber derivatizations between pyriden-4-aldehyde and PFBHA were followed and the derivatives, oximes, were then determined by portable gas chromatography with electron capture detector. The experimental sampling rate of the SPME ozone passive sampler was found to be 1.10 x 10 -4 cm 3 s -1 with detection limit of 58.8 μg m -3 h -1 . Field validations with both SPME device and the direct-reading ozone monitor were also performed. The correlations between the results from both methods were found to be consistent with r = 0.9837. Compared with other methods, the current designed sampler provides a convenient and sensitive tool for the exposure assessments of ozone

  20. Combining Passive Sampling with Toxicological Characterization of Complex Mixtures of Pollutants from the Aquatic Environment.

    Science.gov (United States)

    Jahnke, Annika; Witt, Gesine; Schäfer, Sabine; Haase, Nora; Escher, Beate I

    The combination of polymer-based passive sampling to collect complex environmental mixtures of pollutants, the transfer of these mixtures into bioassays, and their related toxicological characterization is still in its infancy. However, this approach has considerable potential to improve environmental hazard and risk assessment for two reasons. First, the passive sampler collects a broad range of chemicals representing the fraction of compounds available for diffusion and (bio)uptake, excluding a large part of the matrix; thus, extensive sample cleanup which could discriminate certain compounds can be avoided. Second, the toxicological characterization of samples using bioassays is complementary to chemical (target) analysis within environmental monitoring because it captures all chemicals exerting the same mode of toxic action and acting jointly in mixtures, thus providing a comprehensive picture of their overall combined effects. The scientific literature describes a range of examples from the water phase where passive sampling is usually carried out in the kinetic uptake regime for most chemicals although some may already have reached equilibrium. The composition of the chemical mixture changes from the water phase to the passive sampling material because of kinetic effects and polymer/water partition coefficients which depend on the chemicals' hydrophobicity. In contrast, only a few applications in sediment and biota have been described, but amongst these some pioneering studies have demonstrated the feasibility and potential of this combined approach. This chapter gives an overview of what has been carried out in this research area, focusing on opportunities and challenges, and points out desirable future developments with a focus on the importance of choosing a suitable combination of sampling and dosing to transfer (or re-establish) the environmental mixture into the bioassay.

  1. Conceptual design of passive containment cooling system with air holdup tanks of improved APR+

    International Nuclear Information System (INIS)

    Jeon, Byong Guk; Cheon No, Hee

    2014-01-01

    In Korea, after the successful validation of passive auxiliary feedwater system (PAFS), a passive containment cooling system (PCCS) gets attention for future development. We suggested PCCS design based on APR+, an advanced PWR developed in Korea, and performed scoping analysis. On the extension of the simple scoping analysis, MARS simulation is performed to incorporate the behavior of water pool outside the containment as well as steam-air mixture inside the containment. Through the simulation we demonstrated the effectiveness of the air holdup tank (AHT). Also we investigated the effect of the models of heat transfer coefficients between steam-air mixture side and water side, and flow instability inside HX tubes. The presence of AHT enables us to reduce the number of required HX tubes more than half through an increase in the heat transfer coefficients due to the reduction of air fraction in the containment. Finally flow instability was observed and mitigated by putting orifice plates at the inlet of tubes, increasing height of return nozzle, and increasing a tube angle. (authors)

  2. Indoor air quality in passive and conventional new houses in Sweden

    DEFF Research Database (Denmark)

    Langer, Sarka; Bekö, Gabriel; Bloom, Erica

    2015-01-01

    The indoor environment was evaluated in 20 new passive houses and 21 new conventionally built houses during the 2012/2013 and 2013/2014 heating seasons. Temperature, relative humidity (RH), the concentrations of NO2, ozone, formaldehyde, volatile organic compounds (VOC) and viable microbiological...... flora were measured. Air exchange rates (AER) were estimated from the CO2 concentrations measured in the bedrooms. The median AER was slightly higher in the passive houses than in the conventional ones (0.68h-1 vs. 0.60h-1). The median concentrations in the passive and the conventional buildings were 10...... and 12μg/m3 for NO2, 9.7 and 11μg/m3 for ozone, 11 and 16μg/m3 for formaldehyde, and 270 and 150μg/m3 for TVOC, respectively. Significant differences in the TVOC and formaldehyde concentrations between the two groups of buildings indicated substantial sources of TVOC present in the passive houses, while...

  3. A passive air sampler for characterizing the vertical concentration profile of gaseous phase polycyclic aromatic hydrocarbons in near soil surface air.

    Science.gov (United States)

    Zhang, Yuzhong; Deng, Shuxing; Liu, Yanan; Shen, Guofeng; Li, Xiqing; Cao, Jun; Wang, Xilong; Reid, Brian; Tao, Shu

    2011-03-01

    Air-soil exchange is an important process governing the fate of polycyclic aromatic hydrocarbons (PAHs). A novel passive air sampler was designed and tested for measuring the vertical concentration profile of 4 low molecular weight PAHs in gaseous phase (PAH(LMW4)) in near soil surface air. Air at various heights from 5 to 520 mm above the ground was sampled by polyurethane foam disks held in down-faced cartridges. The samplers were tested at three sites: A: an extremely contaminated site, B: a site near A, and C: a background site on a university campus. Vertical concentration gradients were revealed for PAH(LMW4) within a thin layer close to soil surface at the three sites. PAH concentrations either decreased (Site A) or increased (Sites B and C) with height, suggesting either deposition to or evaporation from soils. The sampler is a useful tool for investigating air-soil exchange of gaseous phase semi-volatile organic chemicals. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Evaluation of passive sampling of gaseous mercury using different sorbing materials.

    Science.gov (United States)

    Lin, Huiming; Zhang, Wei; Deng, Chunyan; Tong, Yingdong; Zhang, Qianggong; Wang, Xuejun

    2017-06-01

    Atmospheric mercury monitoring is essential because of its potential human health and ecological impacts. Current automated monitoring systems include limitations such as high cost, complicated configuration, and electricity requirements. Passive samplers require no electric power and are more appropriate for screening applications and long-term monitoring. Sampling rate is a major factor to evaluate the performance of a passive sampler. In this study, laboratory experiments were carried out using an exposure chamber to search for high efficiency sorbents for gaseous mercury. Four types of sorbents, including sulfur-impregnated carbon (SIC), chlorine-impregnated carbon (CIC), bromine-impregnated carbon (BIC), and gold-coated sand (GCS) were evaluated under a wide range of meteorological parameters, including temperature, relative humidity, and wind speed. The results showed that the four sorbents all have a high sampling rate above 0.01 m 3 g -1  day -1 , and wind speed has a positive correlation with the sampling rate. Under different temperature and relative humidity, the sampling rate of SIC keeps stable. The sampling rate of CIC and BIC shows a negative correlation with temperature, and GCS is influenced by all the three meteorological factors. Furthermore, long-term experiments were carried out to investigate the uptake capacity of GCS and SIC. Uptake curves show that the mass amount of sorbent in a passive sampler can influence uptake capacity. In the passive sampler, 0.9 g SIC or 0.9 g GCS can achieve stable uptake efficiency for at least 110 days with gaseous mercury concentration at or below 2 ng/m 3 . For mercury concentration at or below 21 ng/m 3 , 0.9 g SIC can maintain stable uptake efficiency for 70 days, and 0.9 g GCS can maintain stability for 45 days.

  5. Comparison of marine sampling methods for organic contaminants: Passive samplers, water extractions, and live oyster deployment.

    Science.gov (United States)

    Raub, Kristin B; Vlahos, Penny; Whitney, Michael

    2015-08-01

    Laboratory and field trials evaluated the efficacy of three methods of detecting aquatic pesticide concentrations. Currently used pesticides: atrazine, metolachlor, and diazinon and legacy pesticide dieldrin were targeted. Pesticides were extracted using solid-phase extraction (SPE) of water samples, titanium plate passive samplers coated in ethylene vinyl acetate (EVA) and eastern oysters (Crassostrea viginica) as biosamplers. A laboratory study assessed the extraction efficiencies and precision of each method. Passive samplers yielded the highest precision of the three methods (RSD: 3-14% EVA plates; 19-60% oysters; and 25-56% water samples). Equilibrium partition coefficients were derived. A significant relationship was found between the concentration in oyster tissue and the ambient aquatic concentration. In the field (Housatonic River, CT (U.S.)) water sampling (n = 5) detected atrazine at 1.61-7.31 μg L(-1), oyster sampling (n = 2×15) detected dieldrin at n.d.-0.096 μg L(-1) SW and the passive samplers (n = 5×3) detected atrazine at 0.97-3.78 μg L(-1) SW and dieldrin at n.d.-0.68 μg L(-1) SW. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Crossett Hydrogen Sulfide Air Sampling Report

    Science.gov (United States)

    This report summarizes the results of the EPA’s hydrogen sulfide air monitoring conducted along Georgia Pacific’s wastewater treatment system and in surrounding Crossett, AR, neighborhoods in 2017.

  7. [Characterizing spatial patterns of NO(x), SO2 and O3 in Pearl River Delta by passive sampling].

    Science.gov (United States)

    Zhao, Yang; Shao, Min; Wang, Chen; Wang, Bo-Guang; Lu, Si-Hua; Zhong, Liu-Ju

    2011-02-01

    Concentrations of NO(x), SO2 and O3 were measured by passive sampling within 200km x 200km grid in Pearl River Delta (PRD). Sampling period was two weeks in November, 2009. Spatial distributions of NO(x), SO2 and O3 were obtained by Kriging interpolation method. The results were compared with emission inventories and modeling results. The transportations of O3 were evaluated by using backward trajectories of air parcels. During the sampling period, the mean concentrations of NO(x), SO2 and O3 were 75.9 microg/m3, 37.3 microg/m3 and 36.2 microg/m3, respectively. And the highest concentrations of NO(x), SO2 and O3 were 195.7 microg/m3, 95.9 microg/m3 and 81.8 microg/m3. Comparing with routine measurements from the regional monitoring network in PRD, the results by passive method were 18.6%, 33.5% and 37.5% lower for NO(x), SO2 and O3, respectively. The spatial patterns demonstrated that higher NO(x) concentrations often appeared in cities such as Guangzhou, Foshan and Shenzhen. SO2 concentrations were higher in west and lower in east. High SO2 concentrations are mainly from emission of power plants and industrial sources. Concentrations of O3 showed the highest levels in the south of PRD. Backward trajectory analysis for higher ozone areas indicated that 53% of the air masses were from the region with high concentration of NO(x). The horizontal transportation caused higher ozone in the south while lower in north in PRD.

  8. Nadzor vazdušnog prostora pasivnim multisenzorskim sistemima / Air surveillance by passive multisensor systems

    Directory of Open Access Journals (Sweden)

    Miljko Erić

    2004-05-01

    Full Text Available Za sprovođenje savremenih operacija, kako na operativno-strategijskom, tako i na taktič kom nivou, izuzetno je važno da se obezbedi kontinuirani nadzor vazdušnog prostora. Poznato je da su aktivni radarski sistemi, na kojima se kod nas trenutno zasniva nadzor vazdušnog prostora, u ratnim uslovima veoma ranjivi i podložni elektronskim i borbenim dejstvima protivnika, što je u toku rata 1999. godine i praktično potvrđeno. Kao alternativa aktivnim radarskim sistemima nameće se koncept pasivnog nadzora vazdušnog prostora korišćenjem distribuiranih multisenzorskih sistema. Predmet širih istraživanja predstavljaju tehnička rešenja integrisanog multisenzorskog sistema za pasivan nadzor vazdušnog prostora, koji se sastoji od sledećih podsistema za nadzor vazdušnog prostora: na radio-gonimetarskom principu u frekvencijskom opsegu 20-3000 MHz, na zvukometrijskom principu, na principu vizuelnih osmatračkih stanica, na termovizijskom i televizijskom principu. U ovom radu analizirani su opšti principi pasivnog nadzora vazdušnog prostora multisenzorskim sistemima i predložena je tehnička koncepcija radio-goniometarskog i zvukometrijskog podsistema. / It is very important to provide continuous air surveillance in to realize modern operations on the operational-strategic level and tactical, as well. It is well known that active radar systems, on which air surveillance is based in our country, are very vulnerable in war times and susceptible to the electronic counter and combat attacks of the enemy, what is shown practically in 1999 war. Air surveillance by passive multi-sensor systems is a possible alternative to the air surveillance by the active radar systems. Subjects of our wider research are technical solutions of integrated multi-sensor systems for passive air surveillance which consists of the following subsystems: a subsystem for the air communication intelligence within the frequency range 20-3000 MHz based on intercept

  9. Use of bioindicators and passive sampling devices to evaluate ambient ozone concentrations in north central Pennsylvania

    Energy Technology Data Exchange (ETDEWEB)

    Yuska, D.E.; Skelly, J.M.; Ferdinand, J.A.; Stevenson, R.E.; Savage, J.E.; Mulik, J.D.; Hines, A

    2003-09-01

    Passive samplers and bioindicator plants detect ozone air pollution in north central Pennsylvania. - Ambient concentrations of tropospheric ozone and ozone-induced injury to black cherry (Prunus serotina) and common milkweed (Asclepias syriaca) were determined in north central Pennsylvania from 29 May to 5 September 2000 and from 28 May to 18 September 2001. Ogawa passive ozone samplers were utilized within openings at 15 forested sites of which six were co-located with TECO model 49 continuous ozone monitors. A significant positive correlation was observed between the Ogawa passive samplers and the TECO model 49 continuous ozone monitors for the 2000 (r=0.959) and 2001 (r=0.979) seasons. In addition, a significant positive correlation existed in 2000 and 2001 between ozone concentration and elevation (r=0.720) and (r=0.802), respectively. Classic ozone-induced symptoms were observed on black cherry and common milkweed. In 2000, initial injury was observed in early June, whereas for the 2001 season, initial injury was initially observed in late June. During both seasons, injury was noted at most sites by mid- to late-July. Soil moisture potential was measured for the 2001 season and a significant positive relationship (P<0.001) showed that injury to black cherry was a function of cumulative ozone concentrations and available soil moisture.

  10. Use of bioindicators and passive sampling devices to evaluate ambient ozone concentrations in north central Pennsylvania

    International Nuclear Information System (INIS)

    Yuska, D.E.; Skelly, J.M.; Ferdinand, J.A.; Stevenson, R.E.; Savage, J.E.; Mulik, J.D.; Hines, A.

    2003-01-01

    Passive samplers and bioindicator plants detect ozone air pollution in north central Pennsylvania. - Ambient concentrations of tropospheric ozone and ozone-induced injury to black cherry (Prunus serotina) and common milkweed (Asclepias syriaca) were determined in north central Pennsylvania from 29 May to 5 September 2000 and from 28 May to 18 September 2001. Ogawa passive ozone samplers were utilized within openings at 15 forested sites of which six were co-located with TECO model 49 continuous ozone monitors. A significant positive correlation was observed between the Ogawa passive samplers and the TECO model 49 continuous ozone monitors for the 2000 (r=0.959) and 2001 (r=0.979) seasons. In addition, a significant positive correlation existed in 2000 and 2001 between ozone concentration and elevation (r=0.720) and (r=0.802), respectively. Classic ozone-induced symptoms were observed on black cherry and common milkweed. In 2000, initial injury was observed in early June, whereas for the 2001 season, initial injury was initially observed in late June. During both seasons, injury was noted at most sites by mid- to late-July. Soil moisture potential was measured for the 2001 season and a significant positive relationship (P<0.001) showed that injury to black cherry was a function of cumulative ozone concentrations and available soil moisture

  11. Calibration and Application of Passive Sampling in Drinking Water for Perfluoroalkyl Substances

    OpenAIRE

    Persson, Caroline

    2015-01-01

    Perfluoroalkyl substances (PFASs) are global environmental contaminants and a need for monitoring levels has arisen due to their persistency and their ability to bioaccumulate. One relatively novel method of monitoring for both long and short time intervals and generating time-weighted average (TWA) concentrations is passive sampling for which no power, maintenance and supervision is required. The polar organic compound integrative sampler (POCIS) with a weak anion exchange (WAX) sorbent and ...

  12. High-resolution passive sampling of dissolved methane in the water column of lakes in Greenland

    Science.gov (United States)

    Goldman, A. E.; Cadieux, S. B.; White, J. R.; Pratt, L. M.

    2013-12-01

    Arctic lakes are important participants in the global carbon cycle, releasing methane in a warming climate and contributing to a positive feedback to climate change. In order to yield detailed methane budgets and understand the implications of warming on methane dynamics, high-resolution profiles revealing methane behavior within the water column need to be obtained. Single day sampling using disruptive techniques has the potential to result in biases. In order to obtain high-resolution, undisturbed profiles of methane concentration and isotopic composition, this study evaluates a passive sampling method over a multi-day equilibration period. Selected for this study were two small lakes (Gatos Research Methane Carbon Isotope Analyzer. PDB sampling and pump sampling resulted in statistically similar concentrations (R2=0.89), ranging from 0.85 to 135 uM from PDB and 0.74 to 143 uM from pump sampling. In anoxic waters of the lake, where concentrations were high enough to yield robust isotopic results on the LGR MCIA, δ13C were also similar between the two methods, yielding -73‰ from PDB and -74‰ from pump sampling. Further investigation will produce results for a second lake and methane carbon and hydrogen isotopic composition for both lakes. Preliminary results for this passive sampling method are promising. We envision the use of this technique in future studies of dissolved methane and expect that it will provide a more finely resolved vertical profile, allowing for a more complete understanding of lacustrine methane dynamics.

  13. A passive decay-heat removal system for an ABWR based on air cooling

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyasu, E-mail: mochizki@u-fukui.ac.jp [Research Institute of Nuclear Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan); Yano, Takahiro [School of Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan)

    2017-01-15

    Highlights: • A passive decay heat removal system for an ABWR is discussed using combined system of the reactor and an air cooler. • Effect of number of pass of the finned heat transfer tubes on heat removal is investigated. • The decay heat can be removed by air coolers with natural convection. • Two types of air cooler are evaluated, i.e., steam condensing and water cooling types. • Measures how to improve the heat removal rate and to make compact air cooler are discussed. - Abstract: This paper describes the capability of an air cooling system (ACS) operated under natural convection conditions to remove decay heat from the core of an Advanced Boiling Water Reactor (ABWR). The motivation of the present research is the Fukushima Severe Accident (SA). The plant suffered damages due to the tsunami and entered a state of Station Blackout (SBO) during which seawater cooling was not available. To prevent this kind of situation, we proposed a passive decay heat removal system (DHRS) in the previous study. The plant behavior during the SBO was calculated using the system code NETFLOW++ assuming an ABWR with the ACS. However, decay heat removal under an air natural convection was difficult. In the present study, a countermeasure to increase heat removal rate is proposed and plant transients with the ACS are calculated under natural convection conditions. The key issue is decreasing pressure drop over the tube banks in order to increase air flow rate. The results of the calculations indicate that the decay heat can be removed by the air natural convection after safety relief valves are actuated many times during a day. Duct height and heat transfer tube arrangement of the AC are discussed in order to design a compact and efficient AC for the natural convection mode. As a result, a 4-pass heat transfer tubes with 2-row staggered arrangement is the candidate of the AC for the DHRS under the air natural convection conditions. The heat removal rate is re-evaluated as

  14. A Passive Diffusion Sampler for HT- and HTO-in-Air

    International Nuclear Information System (INIS)

    Surette, R.A.; Nunes, J.C.

    2005-01-01

    Fusion research and tritium removal facilities potentially handle large inventories of tritium gas (HT). If any HT is released into the workplace, a fraction may be converted to tritiated water vapour (HTO). A convenient method to determine the activity concentration of each species is necessary to assess the potential hazard since the radiological hazard of HTO is more than 10 4 that due to HT. Passive samplers for measuring tritiated water vapour (HTO) have been shown to be suitable for use indoors and outdoors. These simple samplers consist of a standard 20-mL liquid scintillation vial with a diffusion orifice that determines the sampling rate.The total tritium samplers described herein are passive or diffusion samplers that contain a small amount of AECL-proprietary wet-proofed catalyst fixed to the underside of the sampling heads to allow conversion of the HT to HTO that is subsequently collected in the sink, (HTO), in the bottom of the sampler. After an appropriate sampling time, liquid scintillation cocktail is added to the vial and the activity collected determined by liquid scintillation analysis. When used in conjunction with the conventional HTO passive sampler the difference between the total and HTO samplers can be used to determine the HT fraction ((HT+HTO) - HTO HT). The sampling rates for the modified diffusion sampler were measured to be 4.6 and 8.1 L/d for HTO and HT, respectively. For a fifteen-minute sampling period, passive samplers can be used to measure tritium activity concentrations from 37 kBq/m 3 to 115 MBq/m 3

  15. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    Science.gov (United States)

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. Published by Elsevier B.V.

  16. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods

    Science.gov (United States)

    Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.

    2014-01-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  17. A simple air sampling technique for monitoring nitrous oxide pollution

    Energy Technology Data Exchange (ETDEWEB)

    Austin, J C; Shaw, R; Moyes, D; Cleaton-Jones, P E

    1981-01-01

    A simple, inexpensive device for the continuous low-flow sampling of air was devised to permit monitoring of pollution by gaseous anaesthetics. The device consisted of a water-filled Perspex cylinder in which a double-walled flexible-film gas sample collection bag was suspended. Air samples could be aspirated into the collection bag at flow rates of as low as 1 ml min-1 by allowing the water to drain from the cylinder at a controlled rate. The maintenance of sample integrity with aspiration and storage of samples of nitrous oxide in air at concentrations of 1000, 100 and 30 p.p.m. v/v was examined using gas chromatography. The sample bags retained a mean 94% of the nitrous oxide in air samples containing nitrous oxide 25 p.p.m. over a 72-h storage period.

  18. Venturi Air-Jet Vacuum Ejector For Sampling Air

    Science.gov (United States)

    Hill, Gerald F.; Sachse, Glen W.; Burney, L. Garland; Wade, Larry O.

    1990-01-01

    Venturi air-jet vacuum ejector pump light in weight, requires no electrical power, does not contribute heat to aircraft, and provides high pumping speeds at moderate suctions. High-pressure motive gas required for this type of pump bled from compressor of aircraft engine with negligible effect on performance of engine. Used as source of vacuum for differential-absorption CO-measurement (DACOM), modified to achieve in situ measurements of CO at frequency response of 10 Hz. Provides improvement in spatial resolution and potentially leads to capability to measure turbulent flux of CO by use of eddy-correlation technique.

  19. Perfluoroalkyl substances in aquatic environment-comparison of fish and passive sampling approaches.

    Science.gov (United States)

    Cerveny, Daniel; Grabic, Roman; Fedorova, Ganna; Grabicova, Katerina; Turek, Jan; Kodes, Vit; Golovko, Oksana; Zlabek, Vladimir; Randak, Tomas

    2016-01-01

    The concentrations of seven perfluoroalkyl substances (PFASs) were investigated in 36 European chub (Squalius cephalus) individuals from six localities in the Czech Republic. Chub muscle and liver tissue were analysed at all sampling sites. In addition, analyses of 16 target PFASs were performed in Polar Organic Chemical Integrative Samplers (POCISs) deployed in the water at the same sampling sites. We evaluated the possibility of using passive samplers as a standardized method for monitoring PFAS contamination in aquatic environments and the mutual relationships between determined concentrations. Only perfluorooctane sulphonate was above the LOQ in fish muscle samples and 52% of the analysed fish individuals exceeded the Environmental Quality Standard for water biota. Fish muscle concentration is also particularly important for risk assessment of fish consumers. The comparison of fish tissue results with published data showed the similarity of the Czech results with those found in Germany and France. However, fish liver analysis and the passive sampling approach resulted in different fish exposure scenarios. The total concentration of PFASs in fish liver tissue was strongly correlated with POCIS data, but pollutant patterns differed between these two matrices. The differences could be attributed to the metabolic activity of the living organism. In addition to providing a different view regarding the real PFAS cocktail to which the fish are exposed, POCISs fulfil the Three Rs strategy (replacement, reduction, and refinement) in animal testing. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Potential Use of Passive Sampling for Environmental Monitoring of Petroleum E&P Operations

    Science.gov (United States)

    Traditional environmental monitoring relies on water or soil samples being taken at various time increments and sent to offsite laboratories for analysis. Reliance on grab samples generally captures limited “snapshots” of environmental contaminant concentrations, is time intensive, costly, and generates residual waste from excess sample and/or reagents used in the analysis procedures. As an alternative, we are evaluating swellable organosilica sorbents to create passive sampling systems for monitoring applications. Previous work has focused on absorption and detection of fuels, chlorinated solvents, endocrine disruptors, explosives, pesticides, fluorinated chemicals, and metals including Ba, Sr, Hg, Pb, Fe, Cu, and Zn. The advantages of swellable organosilica are that the material cancapture target compounds for an extended periods of time, does not absorb natural organic matter, and resists biofilm formation since the sorbent possesses an animated surface morphology.

  1. Comparison of POCIS passive samplers vs. composite water sampling: A case study.

    Science.gov (United States)

    Criquet, Justine; Dumoulin, David; Howsam, Michael; Mondamert, Leslie; Goossens, Jean-François; Prygiel, Jean; Billon, Gabriel

    2017-12-31

    The relevance of Polar Organic Chemical Integrative Samplers (POCIS) was evaluated for the assessment of concentrations of 46 pesticides and 19 pharmaceuticals in a small, peri-urban river with multi-origin inputs. Throughout the period of POCIS deployment, 24h-average water samples were collected automatically, and showed the rapid temporal evolution of concentrations of several micropollutants, as well as permitting the calculation of average concentrations in the water phase for comparison with those estimated from POCIS passive samplers. In the daily water samples, cyproconazol, epoxyconazol and imidacloprid showed high temporal variations with concentrations ranging from under the limit of detection up to several hundreds of ngL -1 . Erythromycin, cyprofloxacin and iopromide also increased rapidly up to tens of ngL -1 within a few days. Conversely, atrazine, caffeine, diclofenac, and to a lesser extent carbamazepine and sucralose, were systematically present in the water samples and showed limited variation in concentrations. For most of the substances studied here, the passive samplers gave reliable average concentrations between the minimal and maximal daily concentrations during the time of deployment. For pesticides, a relatively good correlation was clearly established (R 2 =0.89) between the concentrations obtained by POCIS and those gained from average water samples. A slight underestimation of the concentration by POCIS can be attributed to inappropriate sampling rates extracted from the literature and for our system, and new values are proposed. Considering the all data set, 75% of the results indicate a relatively good agreement between the POCIS and the average water samples concentration (values of the ratio ranging between 0,33 and 3). Note further that this agreement between these concentrations remains valid considering different sampling rates extracted from the literature. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Effect of dissolved organic matter on pre-equilibrium passive sampling: A predictive QSAR modeling study.

    Science.gov (United States)

    Lin, Wei; Jiang, Ruifen; Shen, Yong; Xiong, Yaxin; Hu, Sizi; Xu, Jianqiao; Ouyang, Gangfeng

    2018-04-13

    Pre-equilibrium passive sampling is a simple and promising technique for studying sampling kinetics, which is crucial to determine the distribution, transfer and fate of hydrophobic organic compounds (HOCs) in environmental water and organisms. Environmental water samples contain complex matrices that complicate the traditional calibration process for obtaining the accurate rate constants. This study proposed a QSAR model to predict the sampling rate constants of HOCs (polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and pesticides) in aqueous systems containing complex matrices. A homemade flow-through system was established to simulate an actual aqueous environment containing dissolved organic matter (DOM) i.e. humic acid (HA) and (2-Hydroxypropyl)-β-cyclodextrin (β-HPCD)), and to obtain the experimental rate constants. Then, a quantitative structure-activity relationship (QSAR) model using Genetic Algorithm-Multiple Linear Regression (GA-MLR) was found to correlate the experimental rate constants to the system state including physicochemical parameters of the HOCs and DOM which were calculated and selected as descriptors by Density Functional Theory (DFT) and Chem 3D. The experimental results showed that the rate constants significantly increased as the concentration of DOM increased, and the enhancement factors of 70-fold and 34-fold were observed for the HOCs in HA and β-HPCD, respectively. The established QSAR model was validated as credible (R Adj. 2 =0.862) and predictable (Q 2 =0.835) in estimating the rate constants of HOCs for complex aqueous sampling, and a probable mechanism was developed by comparison to the reported theoretical study. The present study established a QSAR model of passive sampling rate constants and calibrated the effect of DOM on the sampling kinetics. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    International Nuclear Information System (INIS)

    Hayes, Robert

    2009-01-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level

  4. Device for electrochemical detection of metal sample surface resistance and passivation against corrosion in electrolyte

    International Nuclear Information System (INIS)

    Urbancik, L.; Bar, J.; Nemec, J.; Sima, A.

    1986-01-01

    The device consists of a teflon vessel with sealing and an opening below the electrolyte level. Into it is submerged an electrode connected to a dc voltage supply whose other pole is connected to a sample of the metal which is pressed to the opening in the sealing with a flexible strap. The teflon vessel and the sealing are integral. The device is simpler and less costly than those manufactured so far. The operating capability of damaged sealing may be renewed by simple mechanical working. The device may be used for detecting the resistance and passivation of steam generator metal tubes. (J.B.). 1 fig

  5. Does equilibrium passive sampling reflect actual in situ bioaccumulation of PAHs and petroleum hydrocarbon mixtures in aquatic worms?

    NARCIS (Netherlands)

    Muijs, B.|info:eu-repo/dai/nl/194995526; Jonker, M.T.O.|info:eu-repo/dai/nl/175518793

    2012-01-01

    Over the past couple of years, several analytical methods have been developed for assessing the bioavailability of environmental contaminants in sediments and soils. Comparison studies suggest that equilibrium passive sampling methods generally provide the better estimates of internal concentrations

  6. PCDD, PCDF, dl-PCB and organochlorine pesticides monitoring in São Paulo City using passive air sampler as part of the Global Monitoring Plan.

    Science.gov (United States)

    Tominaga, M Y; Silva, C R; Melo, J P; Niwa, N A; Plascak, D; Souza, C A M; Sato, M I Z

    2016-11-15

    The persistent organic pollutants (POPs), such as organochlorine pesticides and PCBs, are ordinarily monitored in the aquatic environment or in soil in the environmental quality monitoring programs in São Paulo, Brazil. One of the core matrices proposed in the POPs Global Monitoring Plan (GMP) from the Stockholm Convention list is the ambient air, which is not a usual matrix for POPs monitoring in the country. In this study POP levels were evaluated in the air samples from an urban site in São Paulo City over five years, starting in 2010 as a capacity building project for Latin America and the Caribbean region for POP monitoring in ambient air using passive samplers. Furthermore, after the end of the Project in 2012, the monitoring continued in the same sampling site as means to improving the analytical capacity building and contribute to the GMP data. The POPs monitored were 17 congeners of 2,3,7,8 chloro-substituted PCDDs and PCDFs, dioxin-like PCBs, indicator PCBs, organochlorine pesticides and toxaphene. The results show a slight decrease in PCDD/F, dl-PCBs and indicator PCBs levels along the five years. The organochlorine pesticide endosulfan was present at its highest concentration at the beginning of the monitoring period, but it was below detection level in the last year of the monitoring. Some other organochlorine pesticides were detected close to or below quantitation limits. The compounds identified were dieldrin, chlordane, α-HCH, γ-HCH, heptachlor, heptachlor epoxide, hexachlorobenzene and DDTs. Toxaphene congeners were not detected. These results have confirmed the efficacy of passive sampling for POP monitoring and the capacity building for POP analysis and monitoring was established. However more needs to be done, including expansion of sampling sites, new POPs and studies on sampling rates to be considered in calculating the concentration of POPs in ambient air using a passive sampler. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Workplace air monitoring and sampling practices at DOE facilities

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Selby, J.M.

    1987-01-01

    The Pacific Northwest Laboratory (PNL) surveyed the current air monitoring and sampling practices at U.S. Department of Energy (DOE) facilities as a part of an air monitoring upgrade task. A comprehensive questionnaire was developed and distributed to DOE contractors through the DOE field offices. Twenty-six facilities returned a completed questionnaire. Questionnaire replies indicate a large diversity in air sampling and monitoring practices among DOE facilities. The differences among the facilities exist in monitoring and sampling instrumentation, procedures, calibration, analytical methods, detection levels, and action levels. Many of these differences could be attributed to different operational needs. 5 references, 2 figures, 2 tables

  8. Automated bar coding of air samples at Hanford (ABCASH)

    International Nuclear Information System (INIS)

    Troyer, G.L.; Brayton, D.D.; McNeece, S.G.

    1992-10-01

    This article describes the basis, main features and benefits of an automated system for tracking and reporting radioactive air particulate samples. The system was developed due to recognized need for improving the quality and integrity of air sample data related to personnel and environmental protection. The data capture, storage, and retrieval of air sample data are described. The automation aspect of the associated and data input eliminates a large potential for human error. The system utilizes personal computers, handheld computers, a commercial personal computer database package, commercial programming languages, and complete documentation to satisfy the system's automation objective

  9. Developing a passive trap for diffusive atmospheric {sup 14}CO{sub 2} sampling

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Jennifer C.; Xu, Xiaomei [Department of Earth System Science, University of California, Irvine, Irvine, CA (United States); Fahrni, Simon M. [Department of Earth System Science, University of California, Irvine, Irvine, CA (United States); Institute of Particle Physics, ETH, Zurich (Switzerland); Lupascu, Massimo [Department of Earth System Science, University of California, Irvine, Irvine, CA (United States); Department of Geography, National University of Singapore (Singapore); Czimczik, Claudia I. [Department of Earth System Science, University of California, Irvine, Irvine, CA (United States)

    2015-10-15

    {sup 14}C-CO{sub 2} measurement is an unique tool to quantify source-based emissions of CO{sub 2} for both the urban and natural environments. Acquiring a sample that temporally integrates the atmospheric {sup 14}C-CO{sub 2} signature that allows for precise {sup 14}C analysis is often necessary, but can require complex sampling devices, which can be difficult to deploy and maintain, especially for multiple locations. Here we describe our progress in developing a diffusive atmospheric CO{sub 2} molecular sieve trap, which requires no power to operate. We present results from various cleaning procedures, and rigorously tested for blank and memory effects. Traps were tested in the environment along-side conventional sampling flasks for accuracy. Results show that blank and memory effects can be minimized with thorough cleaning and by avoiding overheating, and that diffusively collected air samples agree well with traditionally canister-sampled air.

  10. Portable monitors for measuring radon and its progenies air by intergrated sampling method

    International Nuclear Information System (INIS)

    Zhang Huaiqin; Su Jingling; Yao Wanyuan; Liu Jinhua

    1989-01-01

    Two kinds of portable monitors have been developed, which can be used to measure the concentration of radon or potential energy concentration of radon or potential energy concentration of radon progenies in air. The thermoluminescent material CaSO 4 (Tm) is used as a detecting element for both of them. The lowest detectable limit of the passive radon monitor is about 1.5 Bq/m 3 for radon in air, as the exposure time being one week. Its main advantages are high reliability and convenient manipulation. The working level monitor for radon progenies in air consists of a mini membrane pump and an integrating probe. The lowest detectable limit is about 6.2 x 10 -9 J/m 3 , as the sampling time being 6 hours. It weights only about 0.35 kg

  11. Determination of plutonium in air and smear samples

    International Nuclear Information System (INIS)

    Hinton, E.R. Jr.; Tucker, W.O.

    1981-01-01

    A method has been developed for the determination of plutonium in air samples and smear samples that were collected on filter papers. The sample papers are digested in nitric acid, extracted into 2-thenoyltrifluoroacetone (TTA)-xylene, and evaporated onto stainless steel disks. Alpha spectrometry is employed to determine the activity of each plutonium isotope. Each sample is spiked with plutonium-236. All glassware used in the procedure is disposable. The detection limits are 3 and 5 dpm (disintegrations per minute) for air and smear samples, respectively, with an average recovery of 87%

  12. EML Surface Air Sampling Program, 1990--1993 data

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of {sup 7}Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb for samples collected during 1990--1993 are given for 17 sites.

  13. EML Surface Air Sampling Program, 1990--1993 data

    International Nuclear Information System (INIS)

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory's Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of 137 Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, 7 Be and 210 Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of 7 Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of 7 Be and 210 Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of 7 Be, 95 Zr, 137 Cs, 144 Ce, and 210 Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of 7 Be, 95 Zr, 137 Cs, 144 Ce, and 210 Pb for samples collected during 1990--1993 are given for 17 sites

  14. Novel Metal-Sulfur-Based Air-Stable Passivation of GaAs with Very Low Surface State Densities

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, Carol I.H.; Baca, Albert G.; Chang, P.-C; Hafich, M.J.; Hammons, B.E.; Zavadil, Kevin R.

    1999-08-09

    A new air-stable electronic surface passivation for GaAs and other III-V compound semiconductors that employs sulfur and a suitable metal ion, e.g., Zn, and that is robust towards plasma dielectric deposition has been developed. Initial improvements in photoluminescence are twice that of S-only treatments and have been preserved for >11 months with SiO{sub x}N{sub y} dielectric encapsulation. Photoluminescence and X-ray photoelectron spectroscopies indicate that the passivation consists of two major components with one being stable for >2 years in air. This process improves heterojunction bipolar transistor current gain for both large and small area devices.

  15. Operational air sampling report, January--June 30, 1992

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1992-09-01

    Nevada Test Site postshot and tunnel events generate beta/gamma fission products. The Reynolds Electrical ampersand Engineering Co., Inc. air sampling program is designed for measurement of these radionuclides at various facilities supporting these events. Monthly radon sampling is done for documentation of working levels in the tunnel complexes, which would be expected to hove the highest radon levels for on-site facilities. Out of a total of 281 air samples taken in the tunnel complexes, 25 showed airborne fission products with concentrations well below their respective Derived Air Concentrations (DAC). All of these were related to event reentry or mineback operations. Tritiated water vapor and radon levels were very similar to previously reported levels. The 975 air samples taken at the Area-6 decontamination bays and laundry were again well below any DAC calculation standard and negative for any airborne fission products from laboratory analyses

  16. Operational air sampling report, July 1--December 31, 1992

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1993-04-01

    Nevada Test Site postshot and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed for measurement of these radionuclides at various facilities supporting these events. Monthly radon sampling is done for documentation of working levels in the tunnel complexes, which would be expected to have the highest radon levels for on-site facilities. Out of a total of 628 air samples taken in the tunnel complexes, 24 showed airborne fission products with concentrations well below their respective Derived Air Concentrations (DAC). All of these were related to event reentry or mineback operations. Tritiated water vapor concentrations were very similar to previously reported levels. The 838 air samples taken at the Area-6 decontamination bays and laundry were again well below any DAC calculation standard and negative for any airborne fission products from laboratory analyses

  17. Comparison of passive sampling and biota for monitoring of tonalide in aquatic environment.

    Science.gov (United States)

    Tumova, Jitka; Grabicova, Katerina; Golovko, Oksana; Koba, Olga; Kodes, Vit; Fedorova, Ganna; Grabic, Roman; Kroupova, Hana Kocour

    2017-10-01

    Synthetic musk compounds are extensively used in personal care and cosmetic products all over the world. Afterwards, they are discharged into the environment mainly because they are not completely removed in wastewater treatment plants. The aim of this study was to investigate if a passive sampler is applicable for the monitoring of tonalide, a polycyclic musk compound, in the aquatic environment and to compare the levels of tonalide in pesticide-polar organic chemical integrative sampler (POCIS) and biota. For this purpose, four sampling localities on the three biggest rivers in the Czech Republic were selected. Tonalide was determined in POCIS at all sampling sites in the concentration ranging from 9 ng/POCIS (Labe River, Hradec Králové) to 25 ng/POCIS (Morava River, Blatec). The locality with the most frequent occurrence of tonalide in biota samples was the Morava River which well corresponded with the highest tonalide concentration in POCIS among sampling sites. The highest number of positive tonalide detections among all studied biota samples was found in fish plasma. To the best of our knowledge, this is the first evidence that tonalide bioaccumulates in fish blood. Tonalide levels were below the limit of quantification in benthos samples at all sampling sites.

  18. The effects of rice canopy on the air-soil exchange of polycyclic aromatic hydrocarbons and organochlorine pesticides using paired passive air samplers.

    Science.gov (United States)

    Wang, Yan; Wang, Shaorui; Luo, Chunling; Li, Jun; Ming, Lili; Zhang, Gan; Li, Xiangdong

    2015-05-01

    The rice canopy in paddy fields can influence the air-soil exchange of organic chemicals. We used paired passive air samplers to assess the exchange of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) in a paddy field, South China. Levels of OCPs and light PAHs were generally higher under the canopy than above it. We found that the rice canopy can physically obstruct the evaporation of most OCPs and light PAHs, and can also act as a barrier to the gaseous deposition of p,p'-DDT and heavy PAHs. Paddy fields can behave as a secondary source of OCPs and light PAHs. The homolog patterns of these two types of chemical varied slightly between the air below and above the rice canopy, implying contributions of different sources. Paired passive air samplers can be used effectively to assess the in situ air-soil exchange of PAHs and OCPs in subtropical paddy fields. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Improving the UNC Passive Aerosol Sampler Model Based on Comparison with Commonly Used Aerosol Sampling Methods.

    Science.gov (United States)

    Shirdel, Mariam; Andersson, Britt M; Bergdahl, Ingvar A; Sommar, Johan N; Wingfors, Håkan; Liljelind, Ingrid E

    2018-03-12

    In an occupational environment, passive sampling could be an alternative to active sampling with pumps for sampling of dust. One passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). It is often analysed by microscopic imaging. Promising results have been shown for particles above 2.5 µm, but indicate large underestimations for PM2.5. The aim of this study was to evaluate, and possibly improve, the UNC sampler for stationary sampling in a working environment. Sampling was carried out at 8-h intervals during 24 h in four locations in an open pit mine with UNC samplers, respirable cyclones, PM10 and PM2.5 impactors, and an aerodynamic particle sizer (APS). The wind was minimal. For quantification, two modifications of the UNC sampler analysis model, UNC sampler with hybrid model and UNC sampler with area factor, were compared with the original one, UNC sampler with mesh factor derived from wind tunnel experiments. The effect of increased resolution for the microscopic imaging was examined. Use of the area factor and a higher resolution eliminated the underestimation for PM10 and PM2.5. The model with area factor had the overall lowest deviation versus the impactor and the cyclone. The intraclass correlation (ICC) showed that the UNC sampler had a higher precision and better ability to distinguish between different exposure levels compared to the cyclone (ICC: 0.51 versus 0.24), but lower precision compared to the impactor (PM10: 0.79 versus 0.99; PM2.5: 0.30 versus 0.45). The particle size distributions as calculated from the different UNC sampler analysis models were visually compared with the distributions determined by APS. The distributions were obviously different when the UNC sampler with mesh factor was used but came to a reasonable agreement when the area factor was used. High resolution combined with a factor based on area only, results in no underestimation of small particles compared to impactors and cyclones and a

  20. Passivation of Molecular n-Doping: Exploring the Limits of Air Stability

    KAUST Repository

    Tietze, Max Lutz; Rose, Bradley Daniel; Schwarze, Martin; Fischer, Axel; Runge, Steffen; Blochwitz-Nimoth, Jan; Lü ssem, Bjö rn; Leo, Karl; Bredas, Jean-Luc

    2016-01-01

    © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. Molecular doping is a key technique for flexible and low-cost organic complementary semiconductor technologies that requires both efficient and stable p- and n-type doping. However, in contrast to molecular p-dopants, highly efficient n-type dopants are commonly sensitive to rapid degradation in air due to their low ionization energies (IEs) required for electron donation, e.g., IE = 2.4 eV for tetrakis(1,3,4,6,7,8-hexahydro-2H-pyrimido[1,2-a]pyrimidinato)ditungsten(II) (W2(hpp)4). Here, the air stability of various host:W2(hpp)4 combinations is compared by conductivity measurements and photoemission spectroscopy. A partial passivation of the n-doping against degradation is found, with this effect identified to depend on the specific energy levels of the host material. Since host-W2(hpp)4 electronic wavefunction hybridization is unlikely due to confinement of the dopant highest occupied molecular orbital (HOMO) to its molecular center, this finding is explained via stabilization of the dopant by single-electron transfer to a host material whose energy levels are sufficiently low for avoiding further charge transfer to oxygen-water complexes. Our results show the feasibility of temporarily handling n-doped organic thin films in air, e.g., during structuring of organic field effect transistors (OFETs) by lithography.

  1. Passivation of Molecular n-Doping: Exploring the Limits of Air Stability

    KAUST Repository

    Tietze, Max Lutz

    2016-03-03

    © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. Molecular doping is a key technique for flexible and low-cost organic complementary semiconductor technologies that requires both efficient and stable p- and n-type doping. However, in contrast to molecular p-dopants, highly efficient n-type dopants are commonly sensitive to rapid degradation in air due to their low ionization energies (IEs) required for electron donation, e.g., IE = 2.4 eV for tetrakis(1,3,4,6,7,8-hexahydro-2H-pyrimido[1,2-a]pyrimidinato)ditungsten(II) (W2(hpp)4). Here, the air stability of various host:W2(hpp)4 combinations is compared by conductivity measurements and photoemission spectroscopy. A partial passivation of the n-doping against degradation is found, with this effect identified to depend on the specific energy levels of the host material. Since host-W2(hpp)4 electronic wavefunction hybridization is unlikely due to confinement of the dopant highest occupied molecular orbital (HOMO) to its molecular center, this finding is explained via stabilization of the dopant by single-electron transfer to a host material whose energy levels are sufficiently low for avoiding further charge transfer to oxygen-water complexes. Our results show the feasibility of temporarily handling n-doped organic thin films in air, e.g., during structuring of organic field effect transistors (OFETs) by lithography.

  2. Strategies for monitoring the emerging polar organic contaminants in water with emphasis on integrative passive sampling.

    Science.gov (United States)

    Söderström, Hanna; Lindberg, Richard H; Fick, Jerker

    2009-01-16

    Although polar organic contaminants (POCs) such as pharmaceuticals are considered as some of today's most emerging contaminants few of them are regulated or included in on-going monitoring programs. However, the growing concern among the public and researchers together with the new legislature within the European Union, the registration, evaluation and authorisation of chemicals (REACH) system will increase the future need of simple, low cost strategies for monitoring and risk assessment of POCs in aquatic environments. In this article, we overview the advantages and shortcomings of traditional and novel sampling techniques available for monitoring the emerging POCs in water. The benefits and drawbacks of using active and biological sampling were discussed and the principles of organic passive samplers (PS) presented. A detailed overview of type of polar organic PS available, and their classes of target compounds and field of applications were given, and the considerations involved in using them such as environmental effects and quality control were discussed. The usefulness of biological sampling of POCs in water was found to be limited. Polar organic PS was considered to be the only available, but nevertheless, an efficient alternative to active water sampling due to its simplicity, low cost, no need of power supply or maintenance, and the ability of collecting time-integrative samples with one sample collection. However, the polar organic PS need to be further developed before they can be used as standard in water quality monitoring programs.

  3. Assessment of PDMS-water partition coefficients: implications for passive environmental sampling of hydrophobic organic compounds

    Science.gov (United States)

    DiFilippo, Erica L.; Eganhouse, Robert P.

    2010-01-01

    Solid-phase microextraction (SPME) has shown potential as an in situ passive-sampling technique in aquatic environments. The reliability of this method depends upon accurate determination of the partition coefficient between the fiber coating and water (Kf). For some hydrophobic organic compounds (HOCs), Kf values spanning 4 orders of magnitude have been reported for polydimethylsiloxane (PDMS) and water. However, 24% of the published data examined in this review did not pass the criterion for negligible depletion, resulting in questionable Kf values. The range in reported Kf is reduced to just over 2 orders of magnitude for some polychlorinated biphenyls (PCBs) when these questionable values are removed. Other factors that could account for the range in reported Kf, such as fiber-coating thickness and fiber manufacturer, were evaluated and found to be insignificant. In addition to accurate measurement of Kf, an understanding of the impact of environmental variables, such as temperature and ionic strength, on partitioning is essential for application of laboratory-measured Kf values to field samples. To date, few studies have measured Kf for HOCs at conditions other than at 20 degrees or 25 degrees C in distilled water. The available data indicate measurable variations in Kf at different temperatures and different ionic strengths. Therefore, if the appropriate environmental variables are not taken into account, significant error will be introduced into calculated aqueous concentrations using this passive sampling technique. A multiparameter linear solvation energy relationship (LSER) was developed to estimate log Kf in distilled water at 25 degrees C based on published physicochemical parameters. This method provided a good correlation (R2 = 0.94) between measured and predicted log Kf values for several compound classes. Thus, an LSER approach may offer a reliable means of predicting log Kf for HOCs whose experimental log Kf values are presently unavailable. Future

  4. Evaluation of a Low-Cost Volatile Organic Compound Passive Sampling Method and Laboratory Intercomparison

    Data.gov (United States)

    U.S. Environmental Protection Agency — This project “fenceline Passive Sampler and Sensor Studies” contains information on several related field efforts that examine use of passive sorbent tubes and...

  5. The passive control of air pollution exposure in Dublin, Ireland: A combined measurement and modelling case study

    International Nuclear Information System (INIS)

    Gallagher, J.; Gill, L.W.; McNabola, A.

    2013-01-01

    This study investigates the potential real world application of passive control systems to reduce personal pollutant exposure in an urban street canyon in Dublin, Ireland. The implementation of parked cars and/or low boundary walls as a passive control system has been shown to minimise personal exposure to pollutants on footpaths in previous investigations. However, previous research has been limited to generic numerical modelling studies. This study combines real-time traffic data, meteorological conditions and pollution concentrations, in a real world urban street canyon before and after the implementation of a passive control system. Using a combination of field measurements and numerical modelling this study assessed the potential impact of passive controls on personal exposure to nitric oxide (NO) concentrations in the street canyon in winter conditions. A calibrated numerical model of the urban street canyon was developed, taking into account the variability in traffic and meteorological conditions. The modelling system combined the computational fluid dynamic (CFD) simulations and a semi-empirical equation, and demonstrated a good agreement with measured field data collected in the street canyon. The results indicated that lane distribution, fleet composition and vehicular turbulence all affected pollutant dispersion, in addition to the canyon geometry and local meteorological conditions. The introduction of passive controls displayed mixed results for improvements in air quality on the footpaths for different wind and traffic conditions. Parked cars demonstrated the most comprehensive passive control system with average improvements in air quality of up to 15% on the footpaths. This study highlights the potential of passive controls in a real street canyon to increase dispersion and improve air quality at street level. - Highlights: • Parked cars and LBWs were assessed as passive controls in an urban street canyon. • The calibrated model combined CFD

  6. The passive control of air pollution exposure in Dublin, Ireland: A combined measurement and modelling case study

    Energy Technology Data Exchange (ETDEWEB)

    Gallagher, J., E-mail: j.gallagher@bangor.ac.uk [School of Energy, Natural Resources and Geography, Bangor University (United Kingdom); Gill, L.W.; McNabola, A. [Dept. of Civil, Structural and Environmental Engineering, Trinity College Dublin (Ireland)

    2013-08-01

    This study investigates the potential real world application of passive control systems to reduce personal pollutant exposure in an urban street canyon in Dublin, Ireland. The implementation of parked cars and/or low boundary walls as a passive control system has been shown to minimise personal exposure to pollutants on footpaths in previous investigations. However, previous research has been limited to generic numerical modelling studies. This study combines real-time traffic data, meteorological conditions and pollution concentrations, in a real world urban street canyon before and after the implementation of a passive control system. Using a combination of field measurements and numerical modelling this study assessed the potential impact of passive controls on personal exposure to nitric oxide (NO) concentrations in the street canyon in winter conditions. A calibrated numerical model of the urban street canyon was developed, taking into account the variability in traffic and meteorological conditions. The modelling system combined the computational fluid dynamic (CFD) simulations and a semi-empirical equation, and demonstrated a good agreement with measured field data collected in the street canyon. The results indicated that lane distribution, fleet composition and vehicular turbulence all affected pollutant dispersion, in addition to the canyon geometry and local meteorological conditions. The introduction of passive controls displayed mixed results for improvements in air quality on the footpaths for different wind and traffic conditions. Parked cars demonstrated the most comprehensive passive control system with average improvements in air quality of up to 15% on the footpaths. This study highlights the potential of passive controls in a real street canyon to increase dispersion and improve air quality at street level. - Highlights: • Parked cars and LBWs were assessed as passive controls in an urban street canyon. • The calibrated model combined CFD

  7. Design and laboratory testing of a new flow-through directional passive air sampler for ambient particulate matter.

    Science.gov (United States)

    Lin, Chun; Solera Garcia, Maria Angeles; Timmis, Roger; Jones, Kevin C

    2011-03-01

    A new type of directional passive air sampler (DPAS) is described for collecting particulate matter (PM) in ambient air. The prototype sampler has a non-rotating circular sampling tray that is divided into covered angular channels, whose ends are open to winds from sectors covering the surrounding 360°. Wind-blown PM from different directions enters relevant wind-facing channels, and is retained there in collecting pools containing various sampling media. Information on source direction and type can be obtained by examining the distribution of PM between channels. Wind tunnel tests show that external wind velocities are at least halved over an extended area of the collecting pools, encouraging PM to settle from the air stream. Internal and external wind velocities are well-correlated over an external velocity range of 2.0-10.0 m s⁻¹, which suggests it may be possible to relate collected amounts of PM simply to ambient concentrations and wind velocities. Measurements of internal wind velocities in different channels show that velocities decrease from the upwind channel round to the downwind channel, so that the sampler effectively resolves wind directions. Computational fluid dynamics (CFD) analyses were performed on a computer-generated model of the sampler for a range of external wind velocities; the results of these analyses were consistent with those from the wind tunnel. Further wind tunnel tests were undertaken using different artificial particulates in order to assess the collection performance of the sampler in practice. These tests confirmed that the sampler can resolve the directions of sources, by collecting particulates preferentially in source-facing channels.

  8. An optimized Line Sampling method for the estimation of the failure probability of nuclear passive systems

    International Nuclear Information System (INIS)

    Zio, E.; Pedroni, N.

    2010-01-01

    The quantitative reliability assessment of a thermal-hydraulic (T-H) passive safety system of a nuclear power plant can be obtained by (i) Monte Carlo (MC) sampling the uncertainties of the system model and parameters, (ii) computing, for each sample, the system response by a mechanistic T-H code and (iii) comparing the system response with pre-established safety thresholds, which define the success or failure of the safety function. The computational effort involved can be prohibitive because of the large number of (typically long) T-H code simulations that must be performed (one for each sample) for the statistical estimation of the probability of success or failure. In this work, Line Sampling (LS) is adopted for efficient MC sampling. In the LS method, an 'important direction' pointing towards the failure domain of interest is determined and a number of conditional one-dimensional problems are solved along such direction; this allows for a significant reduction of the variance of the failure probability estimator, with respect, for example, to standard random sampling. Two issues are still open with respect to LS: first, the method relies on the determination of the 'important direction', which requires additional runs of the T-H code; second, although the method has been shown to improve the computational efficiency by reducing the variance of the failure probability estimator, no evidence has been given yet that accurate and precise failure probability estimates can be obtained with a number of samples reduced to below a few hundreds, which may be required in case of long-running models. The work presented in this paper addresses the first issue by (i) quantitatively comparing the efficiency of the methods proposed in the literature to determine the LS important direction; (ii) employing artificial neural network (ANN) regression models as fast-running surrogates of the original, long-running T-H code to reduce the computational cost associated to the

  9. Passive sampling of bioavailable organic chemicals in Perry County, Missouri cave streams.

    Science.gov (United States)

    Fox, J Tyler; Adams, Ginny; Sharum, Martin; Steelman, Karen L

    2010-12-01

    Two types of passive samplers--semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS)--were deployed in spring 2008 to assess bioavailable concentrations of aquatic contaminants in five cave streams and resurgences in Perry County, Missouri. Study sites represent areas of high cave biodiversity and the only known habitat for grotto sculpin (Cottus carolinae). Time-weighted average (TWA) water concentrations were calculated for 20 compounds (n = 9 SPMDs; n = 11 POCIS) originating primarily from agricultural sources, including two organochlorine insecticides, dieldrin and heptachlor epoxide, which were found at levels exceeding U.S. EPA criteria for the protection of aquatic life. GIS data were used to quantify and map sinkhole distribution and density within the study area. Infiltration of storm runoff and its influence on contaminant transport were also evaluated using land cover and hydrological data. This work provides evidence of cave stream contamination by a mix of organic chemicals and demonstrates the applicability of passive samplers for monitoring water quality in dynamic karst environments where rapid transmission of storm runoff makes instantaneous water sampling difficult.

  10. Tracking human footprints in Antarctica through passive sampling of polycyclic aromatic hydrocarbons in inland lakes.

    Science.gov (United States)

    Yao, Yao; Meng, Xiang-Zhou; Wu, Chen-Chou; Bao, Lian-Jun; Wang, Feng; Wu, Feng-Chang; Zeng, Eddy Y

    2016-06-01

    Freely dissolved polycyclic aromatic hydrocarbons (PAHs) were monitored in seven inland lakes of Antarctica by a polyethylene (PE)-based passive sampling technique, with the objective of tracking human footprints. The measured concentrations of PAHs were in the range of 14-360 ng L(-1) with the highest values concentrated around the Russian Progress II Station, indicating the significance of human activities to the loading of PAHs in Antarctica. The concentrations of PAHs in the inland lakes were in the upper part of the PAHs levels in aquatic environments from remote and background regions across the globe. The composition profiles of PAHs indicated that PAHs in the inland lakes were derived mainly from local oil spills, which was corroborated by a large number of fuel spillage reports from ship and plane crash incidents in Antarctica during recent years. Clearly, local human activities, rather than long-range transport, are the dominant sources of PAH contamination to the inland lakes. Finally, the present study demonstrates the efficacy of PE-based passive samplers for investigating PAHs in the aquatic environment of Antarctica under complex field conditions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. A comparison of passive and active acoustic sampling for a bat community impacted by White-nose syndrome

    Science.gov (United States)

    Coleman, Laci S.; Ford, W. Mark; Dobony, Christopher A.; Britzke, Eric R.

    2014-01-01

    In the summers of 2011 and 2012, we compared passive and active acoustic sampling for bats at 31 sites at Fort Drum Military Installation, New York. We defined active sampling as acoustic sampling that occurred in 30-min intervals between the hours of sunset and 0200 with a user present to manipulate the directionality of the microphone. We defined passive sampling as acoustic sampling that occurred over a 12-h period (1900–0700 hours) without a user present and with the microphone set in a predetermined direction. We detected seven of the nine possible species at Fort Drum, including the federally endangered Indiana bat Myotis sodalis, the proposed-for-listing northern bat M. septentrionalis, the little brown bat M. lucifugus, and the big brown bat Eptesicus fuscus, which are impacted by white-nose syndrome (WNS); and the eastern red bat Lasiurus borealis, the hoary bat L. cinereus, and the silver-haired bat Lasionycteris noctivagans, which are not known to be impacted by WNS. We did not detect two additional WNS-impacted species known to historically occur in the area: the eastern small-footed bat Myotis leibii and the tri-colored bat Perimyotis subflavus. Single-season occupancy models revealed lower detection probabilities of all detected species using active sampling versus passive sampling. Additionally, overall detection probabilities declined in detected WNS-impacted species between years. A paired t-test of simultaneous sampling on 21 occasions revealed that overall recorded foraging activity per hour was greater using active than passive sampling for big brown bats and greater using passive than active sampling for little brown bats. There was no significant difference in recorded activity between methods for other WNS-impacted species, presumably because these species have been so reduced in number that their “apparency” on the landscape is lower. Finally, a cost analysis of standard passive and active sampling protocols revealed that passive

  12. Printed Self-Powered Miniature Air Sampling Sensors

    Directory of Open Access Journals (Sweden)

    Joseph Birmingham

    2017-07-01

    Full Text Available The recent geo-political climate has increased the necessity for autonomous, chip-sized, lightweight, air sampling systems which can quickly detect and characterize chemical, biological, radiological, nuclear, and high explosive (CBRNE hazardous materials and relay the results. To address these issues, we have developed a self-powered 3-D chip architecture that processes air to produce concentrated size- sorted particle (and vapor samples that could be integrated with on-chip nanoelectronic detectors for the discovery of weapons of mass destruction (WMD. The unique air movement approach is composed of a nanoscale energy harvester that provides electricity to a printed ion-drag pump to push air through coated-microstructured arrays. The self-powered microstructured array air sampler was designed using computational fluid dynamics (CFD modeling to collect particles from 1-10 microns at greater than 99.9999 % efficiency with less than 100 Pascal [Pa] pressure drop at a specified air flow rate. Surprisingly, even at minimum air flow rates below specifications, these CFD predictions were matched by experimental results gathered in a Government aerosol chamber. The microstructured array engineered filter equaled the collection capability of a membrane or a high efficiency particle air (HEPA filter at a fraction of the filter pressure drop.

  13. The passive control of air pollution exposure in Dublin, Ireland: a combined measurement and modelling case study.

    Science.gov (United States)

    Gallagher, J; Gill, L W; McNabola, A

    2013-08-01

    This study investigates the potential real world application of passive control systems to reduce personal pollutant exposure in an urban street canyon in Dublin, Ireland. The implementation of parked cars and/or low boundary walls as a passive control system has been shown to minimise personal exposure to pollutants on footpaths in previous investigations. However, previous research has been limited to generic numerical modelling studies. This study combines real-time traffic data, meteorological conditions and pollution concentrations, in a real world urban street canyon before and after the implementation of a passive control system. Using a combination of field measurements and numerical modelling this study assessed the potential impact of passive controls on personal exposure to nitric oxide (NO) concentrations in the street canyon in winter conditions. A calibrated numerical model of the urban street canyon was developed, taking into account the variability in traffic and meteorological conditions. The modelling system combined the computational fluid dynamic (CFD) simulations and a semi-empirical equation, and demonstrated a good agreement with measured field data collected in the street canyon. The results indicated that lane distribution, fleet composition and vehicular turbulence all affected pollutant dispersion, in addition to the canyon geometry and local meteorological conditions. The introduction of passive controls displayed mixed results for improvements in air quality on the footpaths for different wind and traffic conditions. Parked cars demonstrated the most comprehensive passive control system with average improvements in air quality of up to 15% on the footpaths. This study highlights the potential of passive controls in a real street canyon to increase dispersion and improve air quality at street level. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Thermohydraulic modeling of the dry air passive containment cooling system process in the Westinghouse AP-600 ALWR

    Energy Technology Data Exchange (ETDEWEB)

    Harari, R; Weis, Y; Barnea, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    Following postulated events of a LOCA, the passive Containment Cooling System (PCCS) uses dry air to transfer the residual heat by natural circulation. The air flow path, designed between the steel reactor containment hot shell and the concrete shield building, creates an open thermosyphon. The purpose of this inherently safe process is to assure the long term steady-state cooling of the nuclear core after an emergency shutdown (authors).

  15. Experimental verification of air flow rate measurement for representative isokinetic air sampling in ventilation stacks

    International Nuclear Information System (INIS)

    Okruhlica, P.; Mrtvy, M.; Kopecky, Z.

    2009-01-01

    Nuclear facilities are obliged to monitor their discharge's influence on environment. Main monitored factions in NPP's ventilation stacks are usually noble gasses, particulates and iodine. These factions are monitored in air sampled from ventilation stack by means of sampling rosette and bypass followed with on-line measuring monitors and balance sampling devices with laboratory evaluations. Correct air flow rate measurement and representative iso-kinetic air sampling system is essential for physical correct and metrological accurate evaluation of discharge influence on environment. Pairs of measuring sensors (Anemometer, pressure gauge, thermometer and humidity meter) are symmetrically placed in horizontal projection of stack on positions based on measured air flow velocity distribution characteristic, Analogically diameter of sampling rosette nozzles and their placement in the middle of 6 - 7 annuluses are calculated for assurance of representative iso-kinetic sampling. (authors)

  16. Experimental verification of air flow rate measurement for representative isokinetic air sampling in ventilation stacks

    International Nuclear Information System (INIS)

    Okruhlica, P.; Mrtvy, M.; Kopecky, Z.

    2008-01-01

    Nuclear facilities are obliged to monitor their discharge's influence on environment. Main monitored factions in NPP's ventilation stacks are usually noble gasses, particulates and iodine. These factions are monitored in air sampled from ventilation stack by means of sampling rosette and bypass followed with on-line measuring monitors and balance sampling devices with laboratory evaluations. Correct air flow rate measurement and representative iso-kinetic air sampling system is essential for physical correct and metrological accurate evaluation of discharge influence on environment. Pairs of measuring sensors (Anemometer, pressure gauge, thermometer and humidity meter) are symmetrically placed in horizontal projection of stack on positions based on measured air flow velocity distribution characteristic, Analogically diameter of sampling rosette nozzles and their placement in the middle of 6- 7 annuluses are calculated for assurance of representative iso-kinetic sampling. (authors)

  17. Effect of passive acoustic sampling methodology on detecting bats after declines from white nose syndrome

    Science.gov (United States)

    Coleman, Laci S.; Ford, W. Mark; Dobony, Christopher A.; Britzke, Eric R.

    2014-01-01

    Concomitant with the emergence and spread of white-nose syndrome (WNS) and precipitous decline of many bat species in North America, natural resource managers need modified and/or new techniques for bat inventory and monitoring that provide robust occupancy estimates. We used Anabat acoustic detectors to determine the most efficient passive acoustic sampling design for optimizing detection probabilities of multiple bat species in a WNS-impacted environment in New York, USA. Our sampling protocol included: six acoustic stations deployed for the entire duration of monitoring as well as a 4 x 4 grid and five transects of 5-10 acoustic units that were deployed for 6-8 night sample durations surveyed during the summers of 2011-2012. We used Program PRESENCE to determine detection probability and site occupancy estimates. Overall, the grid produced the highest detection probabilities for most species because it contained the most detectors and intercepted the greatest spatial area. However, big brown bats (Eptesicus fuscus) and species not impacted by WNS were detected easily regardless of sampling array. Endangered Indiana (Myotis sodalis) and little brown (Myotis lucifugus) and tri-colored bats (Perimyotis subflavus) showed declines in detection probabilities over our study, potentially indicative of continued WNS-associated declines. Identification of species presence through efficient methodologies is vital for future conservation efforts as bat populations decline further due to WNS and other factors.   

  18. Photodegradation of polyaromatic hydrocarbons in passive air samplers: Field testing different deployment chambers

    International Nuclear Information System (INIS)

    Bartkow, Michael E.; Kennedy, Karen E.; Huckins, James N.; Holling, Neil; Komarova, Tatiana; Mueller, Jochen F.

    2006-01-01

    Semi-permeable membrane devices (SPMDs) were loaded with deuterated anthracene and pyrene as performance reference compounds (PRCs) and deployed at a test site in four different chambers (open and closed box chamber, bowl chamber and cage chamber) for 29 days. The losses of PRCs and the uptake of polyaromatic hydrocarbons (PAHs) from the ambient air were quantified. UV-B levels measured in each deployment chamber indicated that SPMDs would be exposed to the most UV-B in the cage chamber and open box chamber. Significantly less PAHs were quantified in SPMDs deployed in the cage chamber and open box chamber compared to samplers from the other two chambers, suggesting that photodegradation of PAHs had occurred. The loss of PRCs confirmed these results but also showed that photodegradation was occurring in the closed box chamber. The bowl chamber appears to provide the best protection from the influence of direct photodegradation. - Photodegradation/loss of PAHs occurs from passive air samplers (SPMDs) deployed in various sampler chambers

  19. Passive sampling - a tool for targeted screening of emerging pollutants in rivers

    Science.gov (United States)

    Kodes, Vit; Grabic, Roman

    2016-04-01

    A screening of more than 300 pollutants such as pharmaceuticals (analgesics, psycholeptics, antidepressants, antibiotics, beta blockers), PCPs (UV blockers, musk's, repellents), illicit drugs, pesticides, perfluorinated compounds and their metabolites at 22 monitoring sites throughout the Czech Republic was conducted in 2013. POCIS samplers were used in this study. Two types of passive samplers (pesticide and pharmaceutical POCIS) were deployed for 14 days in May and in October, 88 samples were collected in total. In total 265 and 310 target compounds were analyzed in pharmaceutical and pesticide samplers respectively. The chemicals of interest were extracted from the passive samplers according to standardized procedures. LC -MS/MS and LC-MS/HRMS methods were applied for analyses of extracts. 150 of 310 (48%) and 127 of 265 (48%) analyzed substances had been found in pesticide and pharmaceutical samplers respectively. 27 substances (pharmaceuticals, PCPs, pesticides, caffeine, nicotine metabolite cotinine) occurred at all sampled sites, additional 39 substances (pharmaceuticals, PCPs, pesticides) occurred at more than 17 (75%) sites. One of perfluorinated compounds (PFOA) occurred at 68% of sites, whilst one of illicit drugs (Methamphetamine) was found at 61% of sites. The highest number of contaminants found in one POCIS at a single monitoring site was 111. The concentrations varied from nanograms to thousands of nanograms per sampler. Emerging contaminants occurring in highest concentrations (> 1000 ng/sampler) were BP-4 and PBSA (UV blockers), caffeine, DEET (insect repellent), imidacloprid (insecticide), telmisartan (hypertension drug) and tramadol (analgesic). Monitoring in the Czech Republic has demonstrated that many target compounds enter river waters and a number of these compounds reach high concentrations.

  20. Operational air sampling report, July--December 1991

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1992-11-01

    Air sampling is one of the more useful ways of assessing the effectiveness of operational radiation safety programs at the Nevada Test Site (NTS). Air sampling programs document NTS airborne radionuclide concentrations in various work locations and environments. These concentrations generally remain well below the Derived Air Concentration (DAC) values prescribed by the Department of Energy (DOE 5480.11, Attachment 1) or the Derived Concentration Guide (DCG) values prescribed by the Department of Energy DOE 5400.5, Chapter Ill. The Defense Nuclear Agency (DNA) tunnel complexes, Area 12 Test Support Compound and the Area 6 Decontamination Pad and Laundry air sampling programs are summarized in this report. Evaluations are based on Analytical Services Department (ASD) Counting Laboratory analyses and Health Protection Department (HPD)/Radiological Field Operations Section (RFOS) radiation protection technician's (RPT) or health physicists' calculations for air samples collected July 1 through December 31, 1991. Of the NTS operational air sampling programs in the tunnel complexes, the initial mining and event reentry and recovery operations represent the only real airborne radioactive inhalation potentials to personnel. Monthly filter and scintillation cell samples were taken and counted in RDA-200 Radon Detectors to document working levels of radon/thoron daughters and picocurie/liter (PCVL) concentrations of radon gas. Weekly Drierite samples for tritium analysis were taken in the active tunnel complexes to document any changes in normal background levels or reentry drifts as they are advanced toward ground zero (GZ) areas. Underground water sources are considered primary transporters of tritium from old event areas

  1. Transient Performance of Air-cooled Condensing Heat Exchanger in Long-term Passive Cooling System during Decay Heat Load

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myoung Jun; Lee, Hee Joon [Kookmin University, Seoul (Korea, Republic of); Moon, Joo Hyung; Bae, Youngmin; Kim, Young-In [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    In the event of a 'loss of coolant accident'(LOCA) and a non-LOCA, the secondary passive cooling system would be activated to cool the steam in a condensing heat exchanger that is immersed in an emergency cooldown tank (ECT). Currently, the capacities of these ECTs are designed to be sufficient to remove the sensible and residual heat from the reactor coolant system for 72 hours after the occurrence of an accident. After the operation of a conventional passive cooling system for an extended period, however, the water level falls as a result of the evaporation from the ECT, as steam is emitted from the open top of the tank. Therefore, the tank should be refilled regularly from an auxiliary water supply system when the system is used for more than 72 hours. Otherwise, the system would fail to dissipate heat from the condensing heat exchanger due to the loss of the cooling water. Ultimately, the functionality of the passive cooling system would be seriously compromised. As a passive means of overcoming the water depletion in the tank, Kim et al. applied for a Korean patent covering the concept of a long-term passive cooling system for an ECT even after 72 hours. This study presents transient performance of ECT with installing air-cooled condensing heat exchanger under decay heat load. The cooling capacity of an air-cooled condensing heat exchanger was evaluated to determine its practicality.

  2. Air Monitoring: New Advances in Sampling and Detection

    Directory of Open Access Journals (Sweden)

    Nicola Watson

    2011-01-01

    Full Text Available As the harmful effects of low-level exposure to hazardous organic air pollutants become more evident, there is constant pressure to improve the detection limits of indoor and ambient air monitoring methods, for example, by collecting larger air volumes and by optimising the sensitivity of the analytical detector. However, at the other end of the scale, rapid industrialisation in the developing world and growing pressure to reclaim derelict industrial land for house building is driving the need for air monitoring methods that can reliably accommodate very-high-concentration samples in potentially aggressive matrices. This paper investigates the potential of a combination of two powerful gas chromatography—based analytical enhancements—sample preconcentration/thermal desorption and time-of-flight mass spectrometry—to improve quantitative and qualitative measurement of very-low-(ppt level organic chemicals, even in the most complex air samples. It also describes new, practical monitoring options for addressing equally challenging high-concentration industrial samples.

  3. Development of Solid Ceramic Dosimeters for the Time-Integrative Passive Sampling of Volatile Organic Compounds in Waters.

    Science.gov (United States)

    Bonifacio, Riza Gabriela; Nam, Go-Un; Eom, In-Yong; Hong, Yong-Seok

    2017-11-07

    Time-integrative passive sampling of volatile organic compounds (VOCs) in water can now be accomplished using a solid ceramic dosimeter. A nonporous ceramic, which excludes the permeation of water, allowing only gas-phase diffusion of VOCs into the resin inside the dosimeter, effectively captured the VOCs. The mass accumulation of 11 VOCs linearly increased with time over a wide range of aqueous-phase concentrations (16.9 to 1100 μg L -1 ), and the linearity was dependent upon the Henry's constant (H). The average diffusivity of the VOCs in the solid ceramic was 1.46 × 10 -10 m 2 s -1 at 25 °C, which was 4 orders of magnitude lower than that in air (8.09 × 10 -6 m 2 s -1 ). This value was 60% greater than that in the water-permeable porous ceramic (0.92 × 10 -10 m 2 s -1 ), suggesting that its mass accumulation could be more effective than that of porous ceramic dosimeters. The mass accumulation of the VOCs in the solid ceramic dosimeter increased in the presence of salt (≥0.1 M) and with increasing temperature (4 to 40 °C) but varied only slightly with dissolved organic matter concentration. The solid ceramic dosimeter was suitable for the field testing and measurement of time-weighted average concentrations of VOC-contaminated waters.

  4. Sample design considerations of indoor air exposure surveys

    International Nuclear Information System (INIS)

    Cox, B.G.; Mage, D.T.; Immerman, F.W.

    1988-01-01

    Concern about the potential for indoor air pollution has prompted recent surveys of radon and NO 2 concentrations in homes and personal exposure studies of volatile organics, carbon monoxide and pesticides, to name a few. The statistical problems in designing sample surveys that measure the physical environment are diverse and more complicated than those encountered in traditional surveys of human attitudes and attributes. This paper addresses issues encountered when designing indoor air quality (IAQ) studies. General statistical concepts related to target population definition, frame creation, and sample selection for area household surveys and telephone surveys are presented. The implications of different measurement approaches are discussed, and response rate considerations are described

  5. Polycyclic aromatic hydrocarbons in air samples of meat smokehouses

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Olsen, I L; Poulsen, O M

    1992-01-01

    In a screening programme nine Danish meat smokehouses were randomly selected for measurements on concentration of airborne polycyclic aromatic hydrocarbons (PAH). A total of 23 stationary air samples were collected during the entire working period of the kiln either above the kiln doors or approx......In a screening programme nine Danish meat smokehouses were randomly selected for measurements on concentration of airborne polycyclic aromatic hydrocarbons (PAH). A total of 23 stationary air samples were collected during the entire working period of the kiln either above the kiln doors...

  6. Passive sampling methods for contaminated sediments: State of the science for organic contaminants

    Science.gov (United States)

    Lydy, Michael J; Landrum, Peter F; Oen, Amy MP; Allinson, Mayumi; Smedes, Foppe; Harwood, Amanda D; Li, Huizhen; Maruya, Keith A; Liu, Jingfu

    2014-01-01

    This manuscript surveys the literature on passive sampler methods (PSMs) used in contaminated sediments to assess the chemical activity of organic contaminants. The chemical activity in turn dictates the reactivity and bioavailability of contaminants in sediment. Approaches to measure specific binding of compounds to sediment components, for example, amorphous carbon or specific types of reduced carbon, and the associated partition coefficients are difficult to determine, particularly for native sediment. Thus, the development of PSMs that represent the chemical activity of complex compound–sediment interactions, expressed as the freely dissolved contaminant concentration in porewater (Cfree), offer a better proxy for endpoints of concern, such as reactivity, bioaccumulation, and toxicity. Passive sampling methods have estimated Cfree using both kinetic and equilibrium operating modes and used various polymers as the sorbing phase, for example, polydimethylsiloxane, polyethylene, and polyoxymethylene in various configurations, such as sheets, coated fibers, or vials containing thin films. These PSMs have been applied in laboratory exposures and field deployments covering a variety of spatial and temporal scales. A wide range of calibration conditions exist in the literature to estimate Cfree, but consensus values have not been established. The most critical criteria are the partition coefficient between water and the polymer phase and the equilibrium status of the sampler. In addition, the PSM must not appreciably deplete Cfree in the porewater. Some of the future challenges include establishing a standard approach for PSM measurements, correcting for nonequilibrium conditions, establishing guidance for selection and implementation of PSMs, and translating and applying data collected by PSMs. Integr Environ Assess Manag 2014;10:167–178. © 2014 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of

  7. Assessing levels and seasonal variations of current-use pesticides (CUPs) in the Tuscan atmosphere, Italy, using polyurethane foam disks (PUF) passive air samplers

    International Nuclear Information System (INIS)

    Estellano, Victor H.; Pozo, Karla; Efstathiou, Christos; Pozo, Katerine; Corsolini, Simonetta; Focardi, Silvano

    2015-01-01

    Polyurethane foam disks (PUF) passive air samplers (PAS) were deployed over 4 sampling periods of 3–5-months (≥ 1 year) at ten urban and rural locations throughout the Tuscany Region. The purpose was to assess the occurrence and seasonal variations of ten current-use pesticides (CUPs). PUF disk extracts were analyzed using GC–MS. The organophosphates insecticides; chlorpyrifos (3–580 pg m −3 ) and chlorpyrifos-methyl (below detection limit – to 570 pg m −3 ) presented the highest levels in air, and showed seasonal fluctuation coinciding with the growing seasons. The relative proportion urban/(urban + rural) ranged from 0.4 to 0.7 showing no differences between urban and rural concentrations. Air back trajectories analysis showed air masses passing over agricultural fields and potentially enhancing the drift of pesticides into the urban sites. This study represents the first information regarding CUPs in the atmosphere of Tuscany region using PAS-PUF disk. - Highlights: • Current use pesticides (CUPs) were detected in the atmosphere of Tuscany, Italy. • Chlorpyrifos showed the highest concentrations in air with seasonal patterns. • CUPs levels might be influenced by agricultural activities. • No differences were detected between Urban and Rural sites. • Air mass analysis indicated the monitoring sites are influenced by local sources. - Seasonality of CUPs was measured in Tuscany, Italy. Chlorpyrifos showed the highest values. Urban and rural sites showed no differences. Agricultural activities influence CUPs levels in air

  8. Monitoring of atmospheric pollutants passive sampling for the protection of historic buildings and monuments

    Energy Technology Data Exchange (ETDEWEB)

    De Santis, F.; Fino, A.; Vazzana, C.; Allegrini, I. [Consiglio Nazionale delle Ricerche, Istituto Inquinamento Atmosferico, Rome (Italy)

    2001-12-01

    When considering the various possibilities to assess the effects of SO{sub 2} and NO{sub 2} on historic buildings and monuments, a distinction can be made according to the completeness of the scope of the assessment itself. A first approach can be limited to gathering data as they become available through the official bodies established under air quality legislation. This approach is based on a single point measurement where a general purpose monitoring station is located, often quite far from the monument to protect and often without investigating local and temporal variations. A more comprehensive assessment should include a generalisation that covers the territory. This can be made on the basis of the knowledge of the spatial distribution of concentrations and the knowledge of the causes of air pollution. Passive samplers allow the measurement of air quality in numerous sites and to assess the pollutant spatial distribution over a large area with a high resolution. As an application of the method, the spatial distribution of SO{sub 2} and NO{sub 2} in the city of Siracusa, Sicily, Italy, has been studied to identify areas of high deposition fluxes in relation to the protection of buildings and monuments of the historic centre. [Italian] E' noto che gli inquinanti presenti in aria, tra questi in particolare l'SO{sub 2} e l'NO{sub 2}, sono causa di danno sui monumenti e sulle opere d'arte. La valutazione dell'impatto di questi due inquinanti viene solitamente effettuata sulla base del monitoraggio eseguito secondo la legislazione vigente ma spesso lontano dal monumento da proteggere. Cio', evidentemente, non consente di valutare correttamente il grado di rischio al quale un monumento e' esposto poiche' non fornisce informazioni sulle variazioni spaziali e temporali dei due inquinanti in prossimita' del monumento stesso. Allo scopo di raccogliere quindi informazioni complete sulla distribuzione degli inquinanti, e

  9. Air sampling program at the Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Hulett, S.H.

    1975-01-01

    An extensive air sampling program has been developed at the Portsmouth Gaseous Diffusion Plant for monitoring the concentrations of radioactive aerosols present in the atmosphere on plantsite as well as in the environs. The program is designed to minimize exposures of employees and the environment to airborne radioactive particulates. Five different air sampling systems, utilizing either filtration or impaction, are employed for measuring airborne alpha and beta-gamma activity produced from 235 U and 234 Th, respectively. Two of the systems have particle selection capabilities: a personal sampler with a 10-mm nylon cyclone eliminates most particles larger than about 10 microns in diameter; and an Annular Kinetic Impactor collects particulates greater than 0.4 microns in diameter which have a density greater than 12-15 gm/cm 3 . A Hi-Volume Air Sampler and an Eberline Model AIM-3 Scintillation Air Monitor are used in collecting short-term samples for assessing compliance with ''ceiling'' standards or peak concentration limits. A film-sort aperture IBM card system is utilized for continuous 8-hour samples. This sampling program has proven to be both practical and effective for assuring accurate monitoring of the airborne activity associated with plant operations

  10. Sampling density for the quantitative evaluation of air trapping

    International Nuclear Information System (INIS)

    Goris, Michael L.; Robinson, Terry E.

    2009-01-01

    Concerns have been expressed recently about the radiation burden on patient populations, especially children, undergoing serial radiological testing. To reduce the dose one can change the CT acquisition settings or decrease the sampling density. In this study we determined the minimum desirable sampling density to ascertain the degree of air trapping in children with cystic fibrosis. Ten children with cystic fibrosis in stable condition underwent a volumetric spiral CT scan. The degree of air trapping was determined by an automated algorithm for all slices in the volume, and then for 1/2, 1/4, to 1/128 of all slices, or a sampling density ranging from 100% to 1% of the total volume. The variation around the true value derived from 100% sampling was determined for all other sampling densities. The precision of the measurement remained stable down to a 10% sampling density, but decreased markedly below 3.4%. For a disease marker with the regional variability of air trapping in cystic fibrosis, regardless of observer variability, a sampling density below 10% and even more so, below 3.4%, apparently decreases the precision of the evaluation. (orig.)

  11. The development of differential inductors using double air-bridge structure based on integrated passive device technology

    Science.gov (United States)

    Li, Yang; Yao, Zhao; Fu, Xiao-Qian; Li, Zhi-Ming; Shan, Fu-Kai; Wang, Cong

    2017-05-01

    Recently, integrated passive devices have become increasingly popular; inductor realization, in particular, offers interesting high performance for RF modules and systems. In this paper, a development of differential inductor fabricated by integrated passive devices technology using a double air-bridge structure is presented. A study of the model development of the differential inductor is first demonstrated. In this model section, a segment box analysis method is applied to provide a clear presentation of the differential inductor. Compared with other work that only shows a brief description of the process, the integrated passive devices process used to fabricate the inductor in this study is elaborated on. Finally, a characterization of differential inductors with different physical layout parameters is illustrated based on inductance and quality factors, which provides a valuable reference for realizing high performance. The proposed work provides a good solution for the design, fabrication and practical application of RF modules and systems.

  12. Data acquisition and analysis of passive solar cooling effects by storage of out door air in the middle of the night; Shin'ya gaiki chikurei ni yoru shizen reibo koka no jissoku to kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, H.; Kasutani, A. [Komazawa Womens Junior College, Tokyo (Japan); Koizumi, H.

    1998-12-05

    Passive cooling by storing coolness of out door air in the middle of the night in rock bed is realized by air type solar system without any additional equipment. The advantage of the passive cooling is confirmed with measuring performance of the passive cooling effect of air type solar system equipped in our Komazawa Womens Junior College last year. (author)

  13. Passive sampling: A cost-effective method for understanding antibiotic fate, behaviour and impact.

    Science.gov (United States)

    Chen, Chang-Er; Zhang, Hao; Ying, Guang-Guo; Zhou, Li-Jun; Jones, Kevin C

    2015-12-01

    The occurrence of antibiotics in the environment has raised much concern in recent years. Understanding their release, fate and behaviour in the environment is vital to assess potential risks. In this study, a novel passive water sampler - diffusion gradients in thin-films for organics (o-DGT) - was employed to assess the occurrence and removal of antibiotics in two waste water treatment plants (WWTPs) - one in China and the other in the United Kingdom (UK). Of the targeted compounds, 11 of 19 were detected in the Chinese WWTP (ND-200ng/L) and 10 of 40 were found in the UK plant (ND-1380ng/L). Florfenicol, lincomycin, ofloxacin and roxithromycin were most abundant in the Chinese WWTP (influent), while anhydrous erythromycin, ciprofloxacin, trimethoprim, ofloxacin and sulfapyridine were the most abundant in the UK influent samples. Estimated Chinese and UK consumption data are used to interpret the results. Neither of the WWTPs was very effective at removing antibiotics: ~40-50% (overall) was removed by the two plants, with the rest being discharged into the receiving rivers. This is the first study using o-DGT to assess the occurrence and removal of antibiotics in WWTPs. o-DGT is a useful, cost-effective tool to assess WWTP performance and can highlight the effectiveness of treatment steps, which can be applied to wastewater based epidemiology studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Methods for Sampling and Measurement of Compressed Air Contaminants

    International Nuclear Information System (INIS)

    Stroem, L.

    1976-10-01

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  15. Methods for Sampling and Measurement of Compressed Air Contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, L

    1976-10-15

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  16. In-air micro-pixe analysis of tissue samples

    International Nuclear Information System (INIS)

    Tanaka, A.; Ishii, K.; Komori, Y.

    2002-01-01

    Micro-PIXE is capable of providing spatial distributions of elements in the micro-meter scale and its application to biology is useful to elucidate the cellular metabolism. Since, in this method, a sample target is usually irradiated with proton or α-particle beams in vacuum, beam heating results in evaporation of volatile elements an shrinking of the sample. In order to avoid these side effects, we previously developed a technique of in-air micro-PIXE analysis for samples of cultured cells. In addition to these, analysis of exposed tissue samples from living subjects is highly desirable in biological and medical research. Here, we describe a technique of in-air micro-PIXE analysis of such tissue samples. The target samples of exposed tissue slices from a Donryu rat, in which a tumor had been transplanted, were analyzed with proton micro-beams of 2.6 MeV. We report that the shape of cells and the distribution of volatile elements in the tissue sample remain uncharged when using a target preparation based on a freeze-drying method. (author)

  17. Carbon Nanotube Integrative Sampler (CNIS) for passive sampling of nanosilver in the aquatic environment.

    Science.gov (United States)

    Shen, Li; Fischer, Jillian; Martin, Jonathan; Hoque, Md Ehsanul; Telgmann, Lena; Hintelmann, Holger; Metcalfe, Chris D; Yargeau, Viviane

    2016-11-01

    Nanomaterials such as nanosilver (AgNP) can be released into the aquatic environment through production, usage, and disposal. Sensitive and cost-effective methods are needed to monitor AgNPs in the environment. This work is hampered by a lack of sensitive methods to detect nanomaterials in environmental matrixes. The present study focused on the development, calibration and application of a passive sampling technique for detecting AgNPs in aquatic matrixes. A Carbon Nanotube Integrative Sampler (CNIS) was developed using multi-walled carbon nanotubes (CNTs) as the sorbent for accumulating AgNPs and other Ag species from water. Sampling rates were determined in the laboratory for different sampler configurations and in different aquatic matrixes. The sampler was field tested at the Experimental Lakes Area, Canada, in lake water dosed with AgNPs. For a configuration of the CNIS consisting of CNTs bound to carbon fiber (i.e. CNT veil) placed in Chemcatcher® housing, the time weighted average (TWA) concentrations of silver estimated from deployments of the sampler in lake mesocosms dosed with AgNPs were similar to the measured concentrations of "colloidal silver" (i.e. <0.22μm in size) in the water column. For a configuration of CNIS consisting of CNTs in loose powder form placed in a custom made housing that were deployed in a whole lake dosed with AgNPs, the estimated TWA concentrations of "CNIS-labile Ag" were similar to the concentrations of total silver measured in the epilimnion of the lake. However, sampling rates for the CNIS in various matrixes are relatively low (i.e. 1-20mL/day), so deployment periods of several weeks are required to detect AgNPs at environmentally relevant concentrations, which can allow biofilms to develop on the sampler and could affect the sampling rates. With further development, this novel sampler may provide a simple and sensitive method for screening for the presence of AgNPs in surface waters. Copyright © 2016 Elsevier B.V. All

  18. Active AirCore Sampling: Constraining Point Sources of Methane and Other Gases with Fixed Wing Unmanned Aerial Systems

    Science.gov (United States)

    Bent, J. D.; Sweeney, C.; Tans, P. P.; Newberger, T.; Higgs, J. A.; Wolter, S.

    2017-12-01

    Accurate estimates of point source gas emissions are essential for reconciling top-down and bottom-up greenhouse gas measurements, but sampling such sources is challenging. Remote sensing methods are limited by resolution and cloud cover; aircraft methods are limited by air traffic control clearances, and the need to properly determine boundary layer height. A new sampling approach leverages the ability of unmanned aerial systems (UAS) to measure all the way to the surface near the source of emissions, improving sample resolution, and reducing the need to characterize a wide downstream swath, or measure to the full height of the planetary boundary layer (PBL). The "Active-AirCore" sampler, currently under development, will fly on a fixed wing UAS in Class G airspace, spiraling from the surface to 1200 ft AGL around point sources such as leaking oil wells to measure methane, carbon dioxide and carbon monoxide. The sampler collects a 100-meter long sample "core" of air in an 1/8" passivated stainless steel tube. This "core" is run on a high-precision instrument shortly after the UAS is recovered. Sample values are mapped to a specific geographic location by cross-referencing GPS and flow/pressure metadata, and fluxes are quantified by applying Gauss's theorem to the data, mapped onto the spatial "cylinder" circumscribed by the UAS. The AirCore-Active builds off the sampling ability and analytical approach of the related AirCore sampler, which profiles the atmosphere passively using a balloon launch platform, but will add an active pumping capability needed for near-surface horizontal sampling applications. Here, we show design elements, laboratory and field test results for methane, describe the overall goals of the mission, and discuss how the platform can be adapted, with minimal effort, to measure other gas species.

  19. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    Science.gov (United States)

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.

  20. Application of an immobilized ionic liquid for the passive sampling of perfluorinated substances in water.

    Science.gov (United States)

    Wang, Lei; Gong, Xinying; Wang, Ruonan; Gan, Zhiwei; Lu, Yuan; Sun, Hongwen

    2017-09-15

    Ionic liquids have been used to efficiently extract a wide range of polar and nonpolar organic contaminants from water. In this study, imidazole ionic liquids immobilized on silica gel were synthesized through a chemical bonding method, and the immobilized dodecylimidazolium ionic liquid was selected as the receiving phase material in a POCIS (polar organic chemical integrative sampler) like passive sampler to monitor five perfluoroalkyl substances (PFASs) in water. Twenty-one days of integrative accumulation was conducted in laboratory scale experiments, and the accumulated PFASs in the samplers were eluted and analyzed by high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS). The partitioning coefficients of most PFASs between sampler sorbents and water in the immobilized ionic liquid (IIL)-sampler were higher than those in the HLB-sampler, especially for compounds with shorter alkyl chains. The effects of flow velocity, temperature, dissolved organic matter (DOM) and pH on the uptake of these analytes were also evaluated. Under the experimental conditions, the uptake of PFASs in the IIL-sampler slightly increased with the flow velocity and temperature, while different influences of DOM and pH on the uptake of PFAS homologues with short or long chains were observed. The designed IIL-samplers were applied in the influent and effluent of a wastewater treatment plant. All five PFASs could be accumulated in the samplers, with concentrations ranging from 6.5×10 -3 -3.6×10 -1 nmol/L in the influent and from 1.3×10 -2 -2.2×10 -1 nmol/L in the effluent. The calculated time-weighted average concentrations of most PFASs fit well with the detected concentrations of the active sampling, indicating the applicability of the IIL-sampler in monitoring these compounds in water. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Sampling strategies to improve passive optical remote sensing of river bathymetry

    Science.gov (United States)

    Legleiter, Carl; Overstreet, Brandon; Kinzel, Paul J.

    2018-01-01

    Passive optical remote sensing of river bathymetry involves establishing a relation between depth and reflectance that can be applied throughout an image to produce a depth map. Building upon the Optimal Band Ratio Analysis (OBRA) framework, we introduce sampling strategies for constructing calibration data sets that lead to strong relationships between an image-derived quantity and depth across a range of depths. Progressively excluding observations that exceed a series of cutoff depths from the calibration process improved the accuracy of depth estimates and allowed the maximum detectable depth ($d_{max}$) to be inferred directly from an image. Depth retrieval in two distinct rivers also was enhanced by a stratified version of OBRA that partitions field measurements into a series of depth bins to avoid biases associated with under-representation of shallow areas in typical field data sets. In the shallower, clearer of the two rivers, including the deepest field observations in the calibration data set did not compromise depth retrieval accuracy, suggesting that $d_{max}$ was not exceeded and the reach could be mapped without gaps. Conversely, in the deeper and more turbid stream, progressive truncation of input depths yielded a plausible estimate of $d_{max}$ consistent with theoretical calculations based on field measurements of light attenuation by the water column. This result implied that the entire channel, including pools, could not be mapped remotely. However, truncation improved the accuracy of depth estimates in areas shallower than $d_{max}$, which comprise the majority of the channel and are of primary interest for many habitat-oriented applications.

  2. A novel passive water sampler for in situ sampling of antibiotics.

    Science.gov (United States)

    Chen, Chang-Er; Zhang, Hao; Jones, Kevin C

    2012-05-01

    Passive water sampling has several advantages over active methods; it provides time-integrated data, can save on time and cost compared to active methods, and yield high spatial resolution data through co-deployment of simple, cheap units. However, one problem with many sampler designs in current use is that their uptake rates for trace substances of interest are flow-rate dependent, thereby requiring calibration data and other information to enable water concentrations to be derived from the mass per sampler. However, the 'family' of samplers employing the principle of diffusive gradients in thin films (DGT) provides an in situ means of quantitatively measuring labile species in aquatic systems without field calibration. So far, this technique has only been tested and applied in inorganic substances: metals, radionuclides, nutrients, etc. Design and applications of DGT to trace organic contaminants ('o-DGT') would be of widespread interest. This study describes the laboratory testing and performance characteristics of o-DGT, with the antibiotic sulfamethoxazole (SMX) as a model compound and XAD18 as the novel binding agent. o-DGT uptake of SMX increased with time and decreased with diffusion layer thickness, confirming the principle for SMX. XAD18 showed sufficiently high capacity for SMX for routine field applications. o-DGT measurement of SMX was independent of pH (6-9) and ionic strength (0.001-0.1 M) and not affected by flow rate once above static conditions. The diffusion coefficient of SMX in the sampler was measured using an independent diffusion cell and information is presented to allow temperature correction and derivation of aqueous concentrations from deployed samplers. The potential use of o-DGT for in situ measurement of pharmaceutical antibiotics is confirmed by this study and applications are briefly discussed.

  3. Programmable automatic alpha--beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.

    1978-01-01

    A programmable automatic alpha-beta air sample counter was developed for routine sample counting by operational health physics personnel. The system is composed of an automatic sample changer utilizing a large silicon diode detector, an electronic counting system with energy analysis capability, an automatic data acquisition controller, an interface module, and a teletypewriter with paper tape punch and paper tape reader. The system is operated through the teletypewriter keyboard and the paper tape reader, which are used to instruct the automatic data acquisition controller. Paper tape programs are provided for background counting, Chi 2 test, and sample counting. Output data are printed by the teletypewriter on standard continuous roll or multifold paper. Data are automatically corrected for background and counter efficiency

  4. Equilibrium Passive Sampling of POP in Lipid-Rich and Lean Fish Tissue: Quality Control Using Performance Reference Compounds.

    Science.gov (United States)

    Rusina, Tatsiana P; Carlsson, Pernilla; Vrana, Branislav; Smedes, Foppe

    2017-10-03

    Passive sampling is widely used to measure levels of contaminants in various environmental matrices, including fish tissue. Equilibrium passive sampling (EPS) of persistent organic pollutants (POP) in fish tissue has been hitherto limited to application in lipid-rich tissue. We tested several exposure methods to extend EPS applicability to lean tissue. Thin-film polydimethylsiloxane (PDMS) passive samplers were exposed statically to intact fillet and fish homogenate and dynamically by rolling with cut fillet cubes. The release of performance reference compounds (PRC) dosed to passive samplers prior to exposure was used to monitor the exchange process. The sampler-tissue exchange was isotropic, and PRC were shown to be good indicators of sampler-tissue equilibration status. The dynamic exposures demonstrated equilibrium attainment in less than 2 days for all three tested fish species, including lean fish containing 1% lipid. Lipid-based concentrations derived from EPS were in good agreement with lipid-normalized concentrations obtained using conventional solvent extraction. The developed in-tissue EPS method is robust and has potential for application in chemical monitoring of biota and bioaccumulation studies.

  5. Calibration and field performance of membrane-enclosed sorptive coating for integrative passive sampling of persistent organic pollutants in water

    International Nuclear Information System (INIS)

    Vrana, Branislav; Paschke, Albrecht; Popp, Peter

    2006-01-01

    Membrane-enclosed sorptive coating (MESCO) is a miniaturised monitoring device that enables integrative passive sampling of persistent, hydrophobic organic pollutants in water. The system combines the passive sampling with solventless preconcentration of organic pollutants from water and subsequent desorption of analytes on-line into a chromatographic system. Exchange kinetics of chemicals between water and MESCO was studied at different flow rates of water, in order to characterize the effect of variable environmental conditions on the sampler performance, and to identify a method for in situ correction of the laboratory-derived calibration data. It was found that the desorption of chemicals from MESCO into water is isotropic to the absorption of the analytes onto the sampler under the same exposure conditions. This allows for the in situ calibration of the uptake of pollutants using elimination kinetics of performance reference compounds and more accurate estimates of target analyte concentrations. A field study was conducted to test the sampler performance alongside spot sampling. A good agreement of contaminant patterns and water concentrations was obtained by the two sampling techniques. - A robust calibration method of a passive sampling device for monitoring of persistent organic pollutants in water is described

  6. Preliminary assessment of using tree-tissue analysis and passive-diffusion samplers to evaluate trichloroethene contamination of ground water at Site SS-34N, McChord Air Force Base, Washington, 2001

    Science.gov (United States)

    Cox, S.E.

    2002-01-01

    Two low-cost innovative sampling procedures for characterizing trichloroethene (TCE) contamination in ground water were evaluated for use at McChord Air Force Base (AFB) by the U.S. Geological Survey, in cooperation with the U.S. Air Force McChord Air Force Base Installation Restoration Program, in 2001. Previous attempts to characterize the source of ground-water contamination in the heterogeneous glacial outwash aquifer at McChord site SS-34N using soil-gas surveys, direct-push exploration, and more than a dozen ground-water monitoring wells have had limited success. The procedures assessed in this study involved analysis of tree-tissue samples to map underlying ground-water contamination and deploying passive-diffusion samplers to measure TCE concentrations in existing monitoring wells. These procedures have been used successfully at other U.S. Department of Defense sites and have resulted in cost avoidance and accelerated site characterization. Despite the presence of TCE in ground water at site SS-34N, TCE was not detected in any of the 20 trees sampled at the site during either early spring or late summer sampling. The reason the tree tissue procedure was not successful at the McChord AFB site SS-34N may have been due to an inability of tree roots to extract moisture from a water table 30 feet below the land surface, or that concentrations of TCE in ground water were not large enough to be detectable in the tree tissue at the sampling point. Passive-diffusion samplers were placed near the top, middle, and bottom of screened intervals in three monitoring wells and TCE was observed in all samplers. Concentrations of TCE from the passive-diffusion samplers were generally similar to concentrations found in samples collected in the same wells using conventional pumping methods. In contrast to conventional pumping methods, the collection of ground-water samples using the passive-diffusion samples did not generate waste purge water that would require hazardous

  7. Preliminary Analysis on Heat Removal Capacity of Passive Air-Water Combined Cooling Heat Exchanger Using MARS

    International Nuclear Information System (INIS)

    Kim, Seung-Sin; Jeon, Seong-Su; Hong, Soon-Joon; Bae, Sung-Won; Kwon, Tae-Soon

    2015-01-01

    Current design requirement for working time of PAFS heat exchanger is about 8 hours. Thus, it is not satisfied with the required cooling capability for the long term SBO(Station Black-Out) situation that is required to over 72 hours cooling. Therefore PAFS is needed to change of design for 72 hours cooling. In order to acquirement of long terms cooling using PAFS, heat exchanger tube has to be submerged in water tank for long time. However, water in the tank is evaporated by transferred heat from heat exchanger tubes, so water level is gradually lowered as time goes on. The heat removal capacity of air cooling heat exchanger is core parameter that is used for decision of applicability on passive air-water combined cooling system using PAFS in long term cooling. In this study, the development of MARS input model and plant accident analysis are performed for the prediction of the heat removal capacity of air cooling heat exchanger. From analysis result, it is known that inflow air velocity is the decisive factor of the heat removal capacity and predicted air velocity is lower than required air velocity. But present heat transfer model and predicted air velocity have uncertainty. So, if changed design of PAFS that has over 4.6 kW heat removal capacity in each tube, this type heat exchanger can be applied to long term cooling of the nuclear power plant

  8. Impact of heat load location and strength on air flow pattern with a passive chilled beam system

    Energy Technology Data Exchange (ETDEWEB)

    Kosonen, Risto [Halton Oy, Niittyvillankuja 4, 01510 Vantaa (Finland); Saarinen, Pekka; Koskela, Hannu [Finnish Institute of Occupational Health, Lemminkaisenkatu 14-18 B, 20520 Turku (Finland); Hole, Alex [Arup, Rob Leslie-Carter, Level 10, 201 Kent Street, Sydney, NSW 2000 (Australia)

    2010-01-15

    A passive chilled beam is a source of natural convection, creating a flow of cold air directly into the occupied zone. Experiments were conducted in a mock-up of an office room to study the air velocities in the occupied spaces. In addition, velocity profiles are registered when underneath heat loads exist and the cool and warm air flows interact. Experimental laboratory study revealed that in the case of the underneath heat gains, even no upward plume was generated and the dummy only acted as a flow obstacle, having a significant effect on the velocity profile. Furthermore, in an actual occupied office environment, the thermal plumes and the supply air diffuser mixed effectively the whole air volume. The maximum air velocity measured was still below 0.25 m/s with the extremely high heat gain of 164 W/m{sup 2}. The results demonstrate that analysis methods were the interaction of convection flow and jet are not taken into account could not accurately describe air movement and draught risk in the occupied room space. (author)

  9. The effect of DNA degradation bias in passive sampling devices on metabarcoding studies of arthropod communities and their associated microbiota.

    Science.gov (United States)

    Krehenwinkel, Henrik; Fong, Marisa; Kennedy, Susan; Huang, Edward Greg; Noriyuki, Suzuki; Cayetano, Luis; Gillespie, Rosemary

    2018-01-01

    PCR amplification bias is a well-known problem in metagenomic analysis of arthropod communities. In contrast, variation of DNA degradation rates is a largely neglected source of bias. Differential degradation of DNA molecules could cause underrepresentation of taxa in a community sequencing sample. Arthropods are often collected by passive sampling devices, like malaise traps. Specimens in such a trap are exposed to varying periods of suboptimal storage and possibly different rates of DNA degradation. Degradation bias could thus be a significant issue, skewing diversity estimates. Here, we estimate the effect of differential DNA degradation on the recovery of community diversity of Hawaiian arthropods and their associated microbiota. We use a simple DNA size selection protocol to test for degradation bias in mock communities, as well as passively collected samples from actual Malaise traps. We compare the effect of DNA degradation to that of varying PCR conditions, including primer choice, annealing temperature and cycle number. Our results show that DNA degradation does indeed bias community analyses. However, the effect of this bias is of minor importance compared to that induced by changes in PCR conditions. Analyses of the macro and microbiome from passively collected arthropod samples are thus well worth pursuing.

  10. Study on sampling conditions for the monitoring of waste air

    International Nuclear Information System (INIS)

    Moeller, T.J.; Buetefisch, K.A.

    1998-01-01

    The technical codes for radiological monitoring of the waste air released from a radwaste repository demand that sampling for determination of aerosol-borne radioactivity is to be made with a screener equipped with a suitable number of measuring probes extending over the entire cross-sectional surface of the vent. Another requirement is to ensure that the waste air stream passing through the measuring channel is representative, containing the typical, operation-induced distribution of aerosols across the surface to be scanned. The study reported was intended to determine in a scaled-down model (1:10) of a repository ventilating duct the typical spatial distribution of aerosols (3D particulate density) in order to establish information on the type of typical distributions of aerosols, to be used for optimisation of the measuring site and monitoring instruments. (orig./CB) [de

  11. Trends in monitoring pharmaceuticals and personal-care products in the aquatic environment by use of passive sampling devices

    Science.gov (United States)

    Mills, G.A.; Vrana, B.; Allan, I.; Alvarez, D.A.; Huckins, J.N.; Greenwood, R.

    2007-01-01

    The use of passive sampling in monitoring pharmaceuticals and personal-care products (PPCPs) in the aquatic environment is discussed. The utility of passive sampling methods for monitoring the fraction of heavy metals and the biologically available fraction of non-polar organic priority pollutants is recognized and these technologies are being used in surveys of water quality. These devices are used to measure the dissolved fraction and they can yield information that can be used in the development of risk assessments models. These devices can also be used to locate illegal dumping and to monitor specific sources of input of PPCPs into the environment, or to monitor the effectiveness of water treatment processes in the removal of these compounds from wastewater. These devices can provide representative information at low cost which necessitate a combination of laboratory calibration and field studies for emerging pollutants.

  12. Using silver nano particles for sampling of toxic mercury vapors from industrial air sample

    Directory of Open Access Journals (Sweden)

    M. Osanloo

    2014-05-01

    .Conclusion: The presented adsorbent is very useful for sampling of the trace amounts of mercury vapors from air. Moreover, it can be regenerated easily is suitable or sampling at 25 to 70 °C. Due to oxidation of silver and reduction in uptake of nanoparticles, oven temperature of 245 °C is used for the recovery of metallic silver. Low amount of adsorbent, high absorbency, high repeatability for sampling, low cost and high accuracy are of the advantages of the presented method.

  13. Evaluating the precision of passive sampling methods using PRCs in the water column.

    Science.gov (United States)

    To assess these models, four different thicknesses of low-density polyethylene (LDPE) passive samplers were co-deployed for 28 days in the water column at three sites in New Bedford Harbor, MA, USA. Each sampler was pre-loaded with six PCB performance reference compounds (PRCs) t...

  14. Passive Sampling to Capture the Spatial Variability of Coarse Particles by Composition in Cleveland, OH

    Science.gov (United States)

    Passive samplers deployed at 25 sites for three week-long intervals were used to characterize spatial variability in the mass and composition of coarse particulate matter (PM10-2.5) in Cleveland, OH in summer 2008. The size and composition of individual particles deter...

  15. The Consistency of Isotopologues of Ambient Atmospheric Nitric Acid in Passively Collected Samples

    Science.gov (United States)

    Bell, M. D.; Sickman, J. O.; Bytnerowicz, A.; Padgett, P.; Allen, E. B.

    2012-12-01

    Anthropogenic sources of nitrogen oxides have previously been shown to have distinctive isotopic signatures of oxygen and nitrogen. Nylon filters are currently used in passive sampling arrays to measure ambient atmospheric nitric acid concentrations and estimate deposition rates. This experiment measured the ability of nylon filters to consistently collect isotopologues of atmospheric nitric acid in the same ratios as they are present in the atmosphere. Samplers were deployed in continuous stirred tank reactors (CSTR) and at field sites across a nitrogen deposition gradient in Southern California. Filters were exposed over a four week period with individual filters being subjected to 1-4 week exposure times. Extracted nitric acid were measured for δ18O and δ15N ratios and compared for consistency based on length of exposure and amount of HNO3 collected. Filters within the CSTRs collected HNO3 at a consistent rate in both high and low concentration chambers. After two weeks of exposure, the mean δ18O values were within 0.5‰ of the δ18O of the source HNO3 solution. The mean of all weekly exposures were within 0.5‰ of the δ15N of the source solution, but after three weeks, the mean δ15N of adsorbed HNO3 was within 0.2‰. As the length of the exposure increased, the variability of measured delta values decreased for both elements. The field samplers collected HNO3 consistent with previously measured values along a deposition gradient. The mean δ18O at high deposition sites was 52.2‰ compared to 35.7‰ at the low deposition sites. Mean δ15N values were similar at all sites across the deposition gradient. Due to precipitation events occurring during the exposure period, the δ15N and δ18O of nitric acid were highly variable at all field sites. At single sites, changes in δ15N and δ18O were negatively correlated, consistent with two-sourcing mixing dynamics, but the slope of the regressions differed between high and low deposition sites. Anthropogenic

  16. Optimised air-heating for Minergie-P and passive housing; Optimierte Luftheizung fuer Minergie-P und Passivhaeuser

    Energy Technology Data Exchange (ETDEWEB)

    Haas, A.; Dorer, V.

    2004-07-01

    This extensive report for the Swiss Federal Office of Energy (SFOE) presents the results of a project concerning so-called 'passive' houses which exhibit extremely low energy consumption. The authors state that the findings also apply to the Swiss 'Minergie-P' standard. The aims of the project are quoted, including ways of simplifying the air distribution system, possibilities of using air-based heating systems for non-passive housing, how the building's mass can be used as a heat exchanger and for heat storage and what requirements are to be placed on the small wood-fired ovens often found in such houses. Topics discussed include temperatures and temperature gradients, thermal comfort, draught risks and air-flow rates. Further, questions concerning heat-distribution and control systems, fire and noise protection and humidity are discussed, as are heat losses and gains. Examples of dwellings being examined as part of pilot and demonstration projects are given.

  17. Improving toxicity assessment of pesticide mixtures: the use of polar passive sampling devices extracts in microalgae toxicity tests

    Directory of Open Access Journals (Sweden)

    Sandra KIM TIAM

    2016-09-01

    Full Text Available Complexity of contaminants exposure needs to be taking in account for an appropriate evaluation of risks related to mixtures of pesticides released in the ecosystems. Toxicity assessment of such mixtures can be made through a variety of toxicity tests reflecting different level of biological complexity. This paper reviews the recent developments of passive sampling techniques for polar compounds, especially Polar Organic Chemical Integrative Samplers (POCIS and Chemcatcher® and the principal assessment techniques using microalgae in laboratory experiments. The progresses permitted by the coupled use of such passive samplers and ecotoxicology testing as well as their limitations are presented. Case studies combining passive sampling devices (PSD extracts and toxicity assessment toward microorganisms at different biological scales from single organisms to communities level are presented. These case studies, respectively aimed i at characterizing the toxic potential of waters using dose-response curves, and ii at performing microcosm experiments with increased environmental realism in the toxicant exposure in term of cocktail composition and concentration. Finally perspectives and limitations of such approaches for future applications in the area of environmental risk assessment are discussed.

  18. Seasonal Variation in Monthly Average Air Change Rates Using Passive Tracer Gas Measurements

    DEFF Research Database (Denmark)

    Frederiksen, Marie; Bergsøe, Niels Christian; Kolarik, Barbara

    2011-01-01

    in five dwellings in Greater Copenhagen, Denmark. A passive tracer gas technique (Perfluorocarbon) was used to measure ACR in a seven-month period. Considerable differences were observed between the dwellings with monthly ACRs ranging from 0.21 to 1.75 h-1. Only smaller seasonal variations, generally less...... driving forces for natural ventilation is partially compensated by changed occupant behaviour....

  19. Indoor and outdoor poly- and perfluoroalkyl substances (PFASs) in Korea determined by passive air sampler

    International Nuclear Information System (INIS)

    Kim, Seung-Kyu; Shoeib, Mahiba; Kim, Kyeong-Soo; Park, Jong-Eun

    2012-01-01

    Despite concerns to their increasing contribution to ecological and human exposure, the atmospheric levels of poly- and perfluoroalkyl substances (PFASs) have been determined mainly in Europe and North America. This study presents the indoor and outdoor air concentrations of volatile PFASs [fluorotelomer alcohols (FTOHs), and perfluoroalkyl sulfonamides/sulfonamidoethanols/sulfonamide ethyl acetate (FOSAs/FOSEs/FOSEA)] for the first time in Korean cities. In contrast to the good agreement observed for indoor FTOHs levels in Korea and Europea/North America, FOSAs/FOSEs levels were 10–100-fold lower in Korean indoor air, representing a cultural difference of indoor source. Korean outdoor air contained higher PFAS levels than indoor air, and additionally showed different PFAS composition profile from indoor air. Thus, indoor air would not likely be a main contributor to atmospheric PFAS contamination in Korea, in contrast to western countries. Inhalation exposure of volatile PFASs was estimated to be a minor contributor to PFOA and PFOS exposure in Korea. - Highlights: ► Volatile PFASs were measured in indoor and outdoor airs of Korea, for the first time. ► Cultural difference in indoor source was observed for Korea v.s. western countries. ► Furthermore, PFASs concentrations were higher in indoor air than outdoor air. ► Indoor air was not a major contributor to atmospheric PFASs contamination in Korea. ► Release from industrial activities was considered a possible source. - Korean outdoor air showed not only different PFAS composition profile but higher PFAS levels than indoor airs, indicating indoor air would not be a main source to Korean atmospheric PFASs.

  20. Degree of conversion of simplified contemporary adhesive systems as influenced by extended air-activated or passive solvent volatilization modes.

    Science.gov (United States)

    Borges, Boniek C D; Souza-Junior, Eduardo Jose; Brandt, William C; Loguercio, Alessandro D; Montes, Marcos A J R; Puppin-Rontani, Regina M; Sinhoreti, Mario Alexandre Coelho

    2012-01-01

    This study evaluated the effect of five methods of solvent volatilization on the degree of conversion (DC) of nine one-bottle adhesive systems using Fourier transform infrared/attenuated total reflectance (FTIR/ATR) analysis. Nine adhesives were tested: Adper Single Bond 2 (SB), Adper Easy One (EO), One Up Bond F Plus (OUP), One Coat Bond SL (OC), XP Bond (XP), Ambar (AM), Natural Bond (NB), GO, and Stae. The adhesive systems were applied to a zinc-selenide pellet and 1) cured without solvent volatilization, 2) left undisturbed for 10 seconds before curing, 3) left undisturbed for 60 seconds before curing, 4) air-dried with an air stream for 10 seconds before curing, and 5) air-dried with an air stream for 60 seconds before curing. FTIR/ATR spectra were obtained, and the DC was calculated by comparing the aliphatic bonds/reference peaks before and after light activation for 10 seconds (FlashLite 1401). The DC means of each material were analyzed by one-way analysis of variance and post hoc Tukey test (pStae adhesive systems was not affected by the five evaporation conditions. Air-drying for 60 seconds before curing yielded the highest DC for SB, EO, and OC. Extended solvent volatilization time (60 seconds) either with or without air-drying before curing provided the highest DC for AM, NB, XP, and OUP. Thus, the monomer conversion of adhesive systems was material dependent. In general, the 60-second passive or active air-drying modes to volatilize solvents before curing enhanced the degree of conversion for the one-bottle simplified adhesive systems.

  1. Passivity-Based Control for a Micro Air Vehicle Using Unit Quaternions

    Directory of Open Access Journals (Sweden)

    Maria Eusebia Guerrero-Sanchez

    2016-12-01

    Full Text Available In this paper the development and practical implementation of a Passivity-Based Control (PBC algorithm to stabilize an Unmanned Aerial Vehicle (UAV described with unit quaternions are presented. First, a mathematical model based on Euler-Lagrange formulation using a logarithmic mapping in the quaternion space is introduced. Then, a new methodology: a quaternion-passivity-based control is derived, which does not compute excessive and complex Partial Differential Equations (PDEs for synthesizing the control law, making a significant advantage in comparison with other methodologies. Therefore, the control design to a system as the quad-rotor is easily solved by the proposed methodology. Another advantage is the possibility to stabilize quad-rotor full dynamics which may not be possible with classical PBC techniques. Experimental results and numerical simulations to validate our proposed scheme are presented.

  2. Passive sampling of DDT, DDE and DDD in sediments: accounting for degradation processes with reaction-diffusion modeling.

    Science.gov (United States)

    Tcaciuc, A Patricia; Borrelli, Raffaella; Zaninetta, Luciano M; Gschwend, Philip M

    2018-01-24

    Passive sampling is becoming a widely used tool for assessing freely dissolved concentrations of hydrophobic organic contaminants in environmental media. For certain media and target analytes, the time to reach equilibrium exceeds the deployment time, and in such cases, the loss of performance reference compounds (PRCs), loaded in the sampler before deployment, is one of the common ways used to assess the fractional equilibration of target analytes. The key assumption behind the use of PRCs is that their release is solely diffusion driven. But in this work, we show that PRC transformations in the sediment can have a measurable impact on the PRC releases and even allow estimation of that compound's transformation rate in the environment of interest. We found that in both field and lab incubations, the loss of the 13 C 2,4'-DDT PRC from a polyethylene (PE) passive sampler deployed at the sediment-water interface was accelerated compared to the loss of other PRCs ( 13 C-labeled PCBs, 13 C-labeled DDE and DDD). The DDT PRC loss was also accompanied by accumulation in the PE of its degradation product, 13 C 2,4'-DDD. Using a 1D reaction-diffusion model, we deduced the in situ degradation rates of DDT from the measured PRC loss. The in situ degradation rates increased with depth into the sediment bed (0.14 d -1 at 0-10 cm and 1.4 d -1 at 30-40 cm) and although they could not be independently validated, these rates compared favorably with literature values. This work shows that passive sampling users should be cautious when choosing PRCs, as degradation processes can affect some PRC's releases from the passive sampler. More importantly, this work opens up the opportunity for novel applications of passive samplers, particularly with regard to investigating in situ degradation rates, pathways, and products for both legacy and emerging contaminants. However, further work is needed to confirm that the rates deduced from model fitting of PRC loss are a true reflection of DDT

  3. Passive air monitoring of PCBs and PCNs across East Asia: a comprehensive congener evaluation for source characterization.

    Science.gov (United States)

    Hogarh, Jonathan Nartey; Seike, Nobuyasu; Kobara, Yuso; Habib, Ahsan; Nam, Jae-Jak; Lee, Jong-Sik; Li, Qilu; Liu, Xiang; Li, Jun; Zhang, Gan; Masunaga, Shigeki

    2012-02-01

    A comprehensive congener specific evaluation of polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) in the atmosphere was conducted across East Asia in spring 2008, applying polyurethane foam (PUF) disk passive air sampler (PAS) as monitoring device. Mean concentrations derived for Japan, China and Korea were 184 ± 24, 1100 ± 118, and 156 ± 20 pg m(-3) for ∑(202) PCBs, and 9.5 ± 1.5, 61 ± 6, and 16 ± 2.4 pg m(-3) for ∑(63) PCNs, respectively. Relative to reported data from 2004, the present results suggest that air PCBs concentrations have not changed much in Japan and Korea, while it has increased by one order of magnitude in China. From principal component analysis, combustion emerged highly culpable in contemporary emissions of both PCBs and PCNs across the East Asian sub-region. Another factor derived as important to air PCBs was re-emissions/volatilization. Signals from PCBs formulations were also picked, but their general importance was virtually consigned to the re-emissions/volatilization tendencies. On the contrary, counterpart PCNs formulations did not appear to contribute much to air PCNs. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Air sampling methods to evaluate microbial contamination in operating theatres: results of a comparative study in an orthopaedics department.

    Science.gov (United States)

    Napoli, C; Tafuri, S; Montenegro, L; Cassano, M; Notarnicola, A; Lattarulo, S; Montagna, M T; Moretti, B

    2012-02-01

    To evaluate the level of microbial contamination of air in operating theatres using active [i.e. surface air system (SAS)] and passive [i.e. index of microbial air contamination (IMA) and nitrocellulose membranes positioned near the wound] sampling systems. Sampling was performed between January 2010 and January 2011 in the operating theatre of the orthopaedics department in a university hospital in Southern Italy. During surgery, the mean bacterial loads recorded were 2232.9 colony-forming units (cfu)/m(2)/h with the IMA method, 123.2 cfu/m(3) with the SAS method and 2768.2 cfu/m(2)/h with the nitrocellulose membranes. Correlation was found between the results of the three methods. Staphylococcus aureus was detected in 12 of 60 operations (20%) with the membranes, five (8.3%) operations with the SAS method, and three operations (5%) with the IMA method. Use of nitrocellulose membranes placed near a wound is a valid method for measuring the microbial contamination of air. This method was more sensitive than the IMA method and was not subject to any calibration bias, unlike active air monitoring systems. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  5. Measurement of polyurethane foam - air partition coefficients for semivolatile organic compounds as a function of temperature: Application to passive air sampler monitoring.

    Science.gov (United States)

    Francisco, Ana Paula; Harner, Tom; Eng, Anita

    2017-05-01

    Polyurethane foam - air partition coefficients (K PUF-air ) for 9 polycyclic aromatic hydrocarbons (PAHs), 10 alkyl-substituted PAHs, 4 organochlorine pesticides (OCPs) and dibenzothiophene were measured as a function of temperature over the range 5 °C-35 °C, using a generator column approach. Enthalpies of PUF-to-air transfer (ΔH PUF-air , kJ/mol) were determined from the slopes of log K PUF-air versus 1000/T (K), and have an average value of 81.2 ± 7.03 kJ/mol. The log K PUF-air values at 22 °C ranged from 4.99 to 7.25. A relationship for log K PUF-air versus log K OA was shown to agree with a previous relationship based on only polychlorinated biphenyls (PCBs) and derived from long-term indoor uptake study experiments. The results also confirm that the existing K OA -based model for predicting log K PUF-air values is accurate. This new information is important in the derivation of uptake profiles and effective air sampling volumes for PUF disk samplers so that results can be reported in units of concentration in air. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  6. Low-cost monitoring of campylobacter in poultry houses by air sampling and quantitative PCR

    DEFF Research Database (Denmark)

    Søndergaard, Mette Sofie Rousing; Josefsen, Mathilde Hasseldam; Löfström, Charlotta

    2014-01-01

    approximately 10(4) and 10(5) CCE per sample for boot swabs and air, respectively. In conclusion, using air samples combined with quantitative real-time PCR, Campylobacter contamination could be detected earlier than by boot swabs and was found to be a more convenient technique for monitoring and/or to obtain......The present study describes the evaluation of a method for the quantification of Campylobacter by air sampling in poultry houses. Sampling was carried out in conventional chicken houses in Poland, in addition to a preliminary sampling in Denmark. Each measurement consisted of three air samples, two...... standard boot swab fecal samples, and one airborne particle count. Sampling was conducted over an 8-week period in three flocks, assessing the presence and levels of Campylobacter in boot swabs and air samples using quantitative real-time PCR. The detection limit for air sampling was approximately 100...

  7. Passive sampling devices enable capacity building and characterization of bioavailable pesticide along the Niger, Senegal and Bani Rivers of Africa.

    Science.gov (United States)

    Anderson, Kim A; Seck, Dogo; Hobbie, Kevin A; Traore, Anna Ndiaye; McCartney, Melissa A; Ndaye, Adama; Forsberg, Norman D; Haigh, Theodore A; Sower, Gregory J

    2014-04-05

    It is difficult to assess pollution in remote areas of less-developed regions owing to the limited availability of energy, equipment, technology, trained personnel and other key resources. Passive sampling devices (PSDs) are technologically simple analytical tools that sequester and concentrate bioavailable organic contaminants from the environment. Scientists from Oregon State University and the Centre Régional de Recherches en Ecotoxicologie et de Sécurité Environnementale (CERES) in Senegal developed a partnership to build capacity at CERES and to develop a pesticide-monitoring project using PSDs. This engagement resulted in the development of a dynamic training process applicable to capacity-building programmes. The project culminated in a field and laboratory study where paired PSD samples were simultaneously analysed in African and US laboratories with quality control evaluation and traceability. The joint study included sampling from 63 sites across six western African countries, generating a 9000 data point pesticide database with virtual access to all study participants.

  8. Evaluation of spot and passive sampling for monitoring, flux estimation and risk assessment of pesticides within the constraints of a typical regulatory monitoring scheme.

    Science.gov (United States)

    Zhang, Zulin; Troldborg, Mads; Yates, Kyari; Osprey, Mark; Kerr, Christine; Hallett, Paul D; Baggaley, Nikki; Rhind, Stewart M; Dawson, Julian J C; Hough, Rupert L

    2016-11-01

    In many agricultural catchments of Europe and North America, pesticides occur at generally low concentrations with significant temporal variation. This poses several challenges for both monitoring and understanding ecological risks/impacts of these chemicals. This study aimed to compare the performance of passive and spot sampling strategies given the constraints of typical regulatory monitoring. Nine pesticides were investigated in a river currently undergoing regulatory monitoring (River Ugie, Scotland). Within this regulatory framework, spot and passive sampling were undertaken to understand spatiotemporal occurrence, mass loads and ecological risks. All the target pesticides were detected in water by both sampling strategies. Chlorotoluron was observed to be the dominant pesticide by both spot (maximum: 111.8ng/l, mean: 9.35ng/l) and passive sampling (maximum: 39.24ng/l, mean: 4.76ng/l). The annual pesticide loads were estimated to be 2735g and 1837g based on the spot and passive sampling data, respectively. The spatiotemporal trend suggested that agricultural activities were the primary source of the compounds with variability in loads explained in large by timing of pesticide applications and rainfall. The risk assessment showed chlorotoluron and chlorpyrifos posed the highest ecological risks with 23% of the chlorotoluron spot samples and 36% of the chlorpyrifos passive samples resulting in a Risk Quotient greater than 0.1. This suggests that mitigation measures might need to be taken to reduce the input of pesticides into the river. The overall comparison of the two sampling strategies supported the hypothesis that passive sampling tends to integrate the contaminants over a period of exposure and allows quantification of contamination at low concentration. The results suggested that within a regulatory monitoring context passive sampling was more suitable for flux estimation and risk assessment of trace contaminants which cannot be diagnosed by spot

  9. Using a passive air sampler to monitor air-soil exchange of organochlorine pesticides in the pasture of the central Tibetan Plateau.

    Science.gov (United States)

    Wang, Chuanfei; Wang, Xiaoping; Ren, Jiao; Gong, Ping; Yao, Tandong

    2017-02-15

    Air-soil exchange is a key process controlling the fate of persistent organic pollutants (POPs). However, the "sink effect" of soil for POPs in Tibetan pasture has not been clear. In NamCo, in the central Tibetan Plateau (TP) where the land is covered by grass, a modified passive air sampler (PAS) (thickness: 2cm) was tested. Using the PAS, the atmospheric gaseous phase organochlorine pesticides (OCPs) at 11 heights from close-to-surface (2cm) to 200cm above ground, in summer and in winter, were measured. Concentrations of OCPs in summer were higher than those in winter. Both in summer and winter, atmospheric concentrations of OCPs decreased with decreasing height from 200 to 2cm, indicating that OCPs were being deposited from air to soil. Air deposition of OCPs was possibly driven by wind speed. Furthermore, based on air OCPs at 0-3cm near the surface, the interface exchange of OCPs between air and soil was studied by the fugacity method. The results showed that pastural soil in the TP was a "sink" of OCPs even in summer. The mean deposition fluxes of α-HCH, γ-HCH and o,p'-DDT were 0.72, 0.24 and 0.54pg/h/m 2 , respectively, and it was estimated that the level of these pollutants in the soil will double every 24, 66 and 206years, respectively. This study will contribute to the further understanding of global cycling of POPs in different land covers. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Investigation of the Indoor Environment in a Passive House Apartment Building Heated by Ventilation Air

    DEFF Research Database (Denmark)

    Lysholt Hansen, MathiasYoung Bok; Koulani, Chrysanthi Sofia; Peuhkuri, Ruut Hannele

    2014-01-01

    comfort and the performance of the air heating system and solar shading. Thermal comfort category B according to ISO 7730 was obtained in the building during field measurements, indicating that the air heating system was able to maintain comfort conditions in winter, when the outdoor temperature had been...... building project finished medio 2012. The design challenge was met with a concept of air heating that is individually controlled in every room. It also applies external solar shading. This study used indoor climate measurements and dynamic simulations in one of these apartment buildings to evaluate thermal...... unusual low for a longer period. The dynamic simulations also indicated that air heating during winter can provide a comfortable thermal environment. Dynamic simulations also demonstrated that during summer, apartments with automatic external solar screens had no serious overheating, whereas in apartments...

  11. Continuous air monitor correlation to fixed air sample data at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Whicker, J.J.

    1993-01-01

    Continuous air monitoring instruments (CAMS) deployed in laboratories in the TA-55 plutonium facility at Los Alamos National Laboratory (LANL) alarmed less than 33 percent of the time when fixed air sample measurements in the same laboratory showed integrated concentrations exceeding 500 DAC-hrs. The purpose of this study was to explore effects of non-instrument variables on alarm sensitivities for properly working CAMS. Non-instrument variables include air flow patterns, particle size of released material, and the energy of the release. Dilution Factors (DFs) for 21 airborne releases in various rooms and of different magnitudes were calculated and compared. The median DF for releases where the CAM alarmed was 13.1 while the median DF for releases where the CAM did not alarm was 179. Particle sizes ranged considerably with many particles larger than 10 μm. The cause of the release was found to be important in predicting if a CAM would alarm with releases from bagouts resulting in the greatest percentage of CAM alarms. The results of this study suggest that a two-component strategy for CAM placement at LANL be utilized. The first component would require CAMs at exhaust points in the rooms to provide for reliable detection for random release locations. The second component would require placing CAMs at locations where releases have historically been seen. Finally, improvements in CAM instrumentation is needed

  12. Measures of ozone concentrations using passive sampling in forests of South Western Europe

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, M.J. [Fundacion CEAM, Charles R. Darwin 14, Parc Tecnologic, E-46980 Paterna, Valencia (Spain)]. E-mail: mjose@ceam.es; Calatayud, V. [Fundacion CEAM, Charles R. Darwin 14, Parc Tecnologic, E-46980 Paterna, Valencia (Spain); Sanchez-Pena, G. [Servicio de Proteccion de los Montes contra Agentes Nocivos, Direccion General para la Biodiversidad, Ministerio de Medio Ambiente, Gran Via de San Francisco, 4, E-28005, Madrid (Spain)

    2007-02-15

    Ambient ozone concentrations were measured with passive samplers in the framework of the EU and UN/ECE Level II forest monitoring programme. Data from France, Italy, Luxembourg, Spain and Switzerland are reported for 2000-2002, covering the period from April to September. The number of plots increased from 67 in 2000 to 83 in 2002. The year 2001 experienced the highest ozone concentrations, reflecting more stable summer meteorological conditions. Average 6-month ozone concentrations above 45 ppb were measured this year in 40.3% of the plots, in contrast with the less than 21% measured in the other 2 years. Gradients of increasing ozone levels were observed from North to South and with altitude. Comments are made on the regional trends and on the time frame of the higher ozone episodes. Also, some recommendations enabling a better comparison between plots are provided. - Ozone concentrations in forested areas of SW Europe during the period 2000-2002 showed highest values in 2001, as well as a tendency to increase towards the South and with altitude.

  13. Measures of ozone concentrations using passive sampling in forests of South Western Europe

    International Nuclear Information System (INIS)

    Sanz, M.J.; Calatayud, V.; Sanchez-Pena, G.

    2007-01-01

    Ambient ozone concentrations were measured with passive samplers in the framework of the EU and UN/ECE Level II forest monitoring programme. Data from France, Italy, Luxembourg, Spain and Switzerland are reported for 2000-2002, covering the period from April to September. The number of plots increased from 67 in 2000 to 83 in 2002. The year 2001 experienced the highest ozone concentrations, reflecting more stable summer meteorological conditions. Average 6-month ozone concentrations above 45 ppb were measured this year in 40.3% of the plots, in contrast with the less than 21% measured in the other 2 years. Gradients of increasing ozone levels were observed from North to South and with altitude. Comments are made on the regional trends and on the time frame of the higher ozone episodes. Also, some recommendations enabling a better comparison between plots are provided. - Ozone concentrations in forested areas of SW Europe during the period 2000-2002 showed highest values in 2001, as well as a tendency to increase towards the South and with altitude

  14. Improved hybrid isolator with maglev actuator integrated in air spring for active-passive isolation of ship machinery vibration

    Science.gov (United States)

    Li, Yan; He, Lin; Shuai, Chang-geng; Wang, Chun-yu

    2017-10-01

    A hybrid isolator consisting of maglev actuator and air spring is proposed and developed for application in active-passive vibration isolation system of ship machinery. The dynamic characteristics of this hybrid isolator are analyzed and tested. The stability and adaptability of this hybrid isolator to shock and swing in the marine environment are improved by a compliant gap protection technique and a disengageable suspended structure. The functions of these new engineering designs are proved by analytical verification and experimental validation of the designed stiffness of such a hybrid isolator, and also by shock adaptability testing of the hybrid isolator. Finally, such hybrid isolators are installed in an engineering mounting loaded with a 200-kW ship diesel generator, and the broadband and low-frequency sinusoidal isolation performance is tested.

  15. Effect of bio-cover equipped with a novel passive air diffusion system on methane emission reduciton from landfill

    DEFF Research Database (Denmark)

    Lu, W.J.; Mou, Zishen

    2011-01-01

    Based on the aerothermodynamic principles, a kind of breathing bio-cover system was designed to enhance oxygen (O2) supply efficiency and methane (CH4) oxidation capacity. The research showed that O2 concentration (v/v) considerably increased throughout whole profiles of the microcosm (1m) equipped...... with passive air diffusion system (MPADS). When the simulated landfill gas SLFG flow was 771 and 1028 gm−3 d−1, the O2 concentration in MPADS increased gradually and tended to be stable at the atmospheric level after 10 days. The CH4 oxidation rate was 100% when the SLFG flow rate was no more than 1285 gm−3 d......−1, which also was confirmed by the mass balance calculations. The breathing bio-cover system with in situ self-oxygen supply can address the problem of O2 insufficient in conventional landfill bio-cover. The proposed system presents high potential for improving CH4 emission reduction in landfills....

  16. Occurrence of contaminants of emerging concern along the California coast (2009-10) using passive sampling devices

    Science.gov (United States)

    Alvarez, David A.; Maruya, Keith A.; Dodder, Nathan G.; Lao, Wenjian; Furlong, Edward T.; Smalling, Kelly L.

    2014-01-01

    Three passive sampling devices (PSDs), polar organic chemical integrative samplers (POCIS), polyethylene devices (PEDs), and solid-phase microextraction (SPME) samplers were used to sample a diverse set of chemicals in the coastal waters of San Francisco Bay and the Southern California Bight. Seventy one chemicals (including fragrances, phosphate flame retardants, pharmaceuticals, PAHs, PCBs, PBDEs, and pesticides) were measured in at least 50% of the sites. The chemical profile from the San Francisco Bay sites was distinct from profiles from the sites in the Southern California Bight. This distinction was not due to a single compound or class, but by the relative abundances/concentrations of the chemicals. Comparing the PSDs to mussel (Mytilus spp.) tissues, a positive correlation exists for the 25 and 26 chemicals in common for the PEDs and SPME, respectively. Diphenhydramine was the only common chemical out of 40 analyzed in both POCIS and tissues detected at a common site.

  17. Validation of Passive Sampling Devices for Monitoring of Munitions Constituents in Underwater Environments

    Science.gov (United States)

    2017-09-01

    and sampling handling was met. All calibration criteria and instrument maintenance was met for all final reported data. 23 3.2 QUALITATIVE ...the relatively large size of each sampling box within the grid, there were no issues associated with locating appropriate anchoring locations, based...quantiative, as only estimated sampling rates were available, or spiked recoveries were lower suggesting the results are qualitative . TNT RDX ADNTs

  18. Automated Sampling and Extraction of Krypton from Small Air Samples for Kr-85 Measurement Using Atom Trap Trace Analysis

    International Nuclear Information System (INIS)

    Hebel, S.; Hands, J.; Goering, F.; Kirchner, G.; Purtschert, R.

    2015-01-01

    Atom-Trap-Trace-Analysis (ATTA) provides the capability of measuring the Krypton-85 concentration in microlitre amounts of krypton extracted from air samples of about 1 litre. This sample size is sufficiently small to allow for a range of applications, including on-site spot sampling and continuous sampling over periods of several hours. All samples can be easily handled and transported to an off-site laboratory for ATTA measurement, or stored and analyzed on demand. Bayesian sampling methodologies can be applied by blending samples for bulk measurement and performing in-depth analysis as required. Prerequisite for measurement is the extraction of a pure krypton fraction from the sample. This paper introduces an extraction unit able to isolate the krypton in small ambient air samples with high speed, high efficiency and in a fully automated manner using a combination of cryogenic distillation and gas chromatography. Air samples are collected using an automated smart sampler developed in-house to achieve a constant sampling rate over adjustable time periods ranging from 5 minutes to 3 hours per sample. The smart sampler can be deployed in the field and operate on battery for one week to take up to 60 air samples. This high flexibility of sampling and the fast, robust sample preparation are a valuable tool for research and the application of Kr-85 measurements to novel Safeguards procedures. (author)

  19. Passive Acoustic Source Localization at a Low Sampling Rate Based on a Five-Element Cross Microphone Array

    Directory of Open Access Journals (Sweden)

    Yue Kan

    2015-06-01

    Full Text Available Accurate acoustic source localization at a low sampling rate (less than 10 kHz is still a challenging problem for small portable systems, especially for a multitasking micro-embedded system. A modification of the generalized cross-correlation (GCC method with the up-sampling (US theory is proposed and defined as the US-GCC method, which can improve the accuracy of the time delay of arrival (TDOA and source location at a low sampling rate. In this work, through the US operation, an input signal with a certain sampling rate can be converted into another signal with a higher frequency. Furthermore, the optimal interpolation factor for the US operation is derived according to localization computation time and the standard deviation (SD of target location estimations. On the one hand, simulation results show that absolute errors of the source locations based on the US-GCC method with an interpolation factor of 15 are approximately from 1/15- to 1/12-times those based on the GCC method, when the initial same sampling rates of both methods are 8 kHz. On the other hand, a simple and small portable passive acoustic source localization platform composed of a five-element cross microphone array has been designed and set up in this paper. The experiments on the established platform, which accurately locates a three-dimensional (3D near-field target at a low sampling rate demonstrate that the proposed method is workable.

  20. PASSIVE SAMPLING OF GROUND WATER MONITORING WELLS WITHOUT PURGING MULTILEVEL WELL CHEMISTRY AND TRACER DISAPPEARANCE

    Science.gov (United States)

    It is essential that the sampling techniques utilized in groundwater monitoring provide data that accurately depicts the water quality of the sampled aquifer in the vicinity of the well. Due to the large amount of monitoring activity currently underway in the U.S.A. it is also im...

  1. The determination of nitrogen dioxide in ambient air with free hanging filters as passive samplers, and a new calibration method using fritted bubblers.

    Science.gov (United States)

    Heeres, Paul; Setiawan, Rineksa; Krol, Maarten Cornelis; Adema, Eduard Hilbrand

    2009-12-01

    This paper describes two new methods for the determination of NO(2) in the ambient air. The first method consists of free hanging filters with a diameter of 2.5 cm as passive samplers. The filters are impregnated with triethanolamine to bind NO(2). With standard colorimetrical analysis, the amount of NO(2) on the filters is determined. The second method is performed with fritted bubblers filled with Saltzman reagent, where, with a special procedure the absorption efficiencies of the bubblers are determined using ambient air, without the use of standard gases and electronic analytical instruments. The results of the bubblers are used to calibrate the free hanging filters. The two methods were applied simultaneously in the city of Yogyakarta, Indonesia. The methods are inexpensive and very well suited for use in low-budget situations. A characteristic of the free filter is the Sampling Volume, SV. This is the ratio of the amount of NO(2) on the filter and the ambient concentration. With the filter used in this study, the amount of triethanolamine and exposure time, the SV is 0.0166 m(3). The sampling rate (SR) of the filter, 4.6 cm(3)/s, is high. Hourly averaged measurements are performed for 15 hours per day in four busy streets. The measured amounts of NO(2) on the filters varied between 0.57 and 2.02 microg NO(2), at ambient air concentrations of 32 to 141 microg/m(3) NO(2). During the experiments the wind velocity was between 0.2 and 2.0 m/s, the relative humidity between 24 and 83 % and the temperature between 295 K and 311 K. These variations in weather conditions have no influence on the uptake of NO(2).

  2. Use of criteria pollutants, active and passive mercury sampling, and receptor modeling to understand the chemical forms of gaseous oxidized mercury in Florida

    Science.gov (United States)

    Huang, J.; Miller, M. B.; Edgerton, E.; Gustin, M. S.

    2015-04-01

    The highest mercury (Hg) wet deposition in the United States (US) occurs along the Gulf of Mexico, and in the southern and central Mississippi River Valley. Gaseous oxidized Hg (GOM) is thought to be a major contributor due to its high water solubility and reactivity. Therefore, it is critical to understand the concentrations, potential for wet and dry deposition, and GOM compounds present in the air. Concentrations and dry deposition fluxes of GOM were measured at Outlying Landing Field (OLF), Florida, using a Tekran® 2537/1130/1135, and active and passive samplers using cation-exchange and nylon membranes. Relationships with Tekran® derived data must be interpreted with caution, since GOM concentrations can be biased low depending on the chemical compounds in air, and interferences with water vapor and ozone. Only gaseous elemental Hg and GOM are discussed here since the PBM measurement uncertainties are higher. Criteria air pollutants were concurrently measured and Tekran® data were assessed along with these using Principal Component Analysis to identify associations among air pollutants. Based on the diel pattern, high GOM concentrations at this site were associated with fossil fuel combustion and gas phase oxidation during the day, and gas phase oxidation and transport in the free troposphere. The ratio of GEM/CO at OLF (0.008 ng m-3 ppbv-1) was much higher than the numbers reported for the Western United States and central New York for domestic emissions or biomass burning (0.001 ng m-3 ppbv-1), which we suggest is indicative of a marine boundary layer source. Results from nylon membranes with thermal desorption analyses suggest five potential GOM compounds exist in this area, including HgBr2, HgO, Hg(NO3)2, HgSO4, and an unknown compound. This indicates that the site is influenced by different gaseous phase reactions and sources. A~high GOM event related to high CO but average SO2 suggests the air parcels moved from the free troposphere and across

  3. Does Passive Sampling Accurately Reflect the Bee (Apoidea: Anthophila) Communities Pollinating Apple and Sour Cherry Orchards?

    Science.gov (United States)

    Gibbs, Jason; Joshi, Neelendra K; Wilson, Julianna K; Rothwell, Nikki L; Powers, Karen; Haas, Mike; Gut, Larry; Biddinger, David J; Isaacs, Rufus

    2017-06-01

    During bloom of spring orchard crops, bees are the primary providers of pollination service. Monitoring these insects for research projects is often done by timed observations or by direct aerial netting, but there has been increasing interest in blue vane traps as an efficient passive approach to collecting bees. Over multiple spring seasons in Michigan and Pennsylvania, orchards were monitored for wild bees using timed netting from crop flowers and blue vane traps. This revealed a distinctly different community of wild bees captured using the two methods, suggesting that blue vane traps can complement but cannot replace direct aerial netting. The bee community in blue vane traps was generally composed of nonpollinating species, which can be of interest for broader biodiversity studies. In particular, blue vane traps caught Eucera atriventris (Smith), Eucera hamata (Bradley), Bombus fervidus (F.), and Agapostemon virescens (F.) that were never collected from the orchard crop flowers during the study period. Captures of bee species in nets was generally stable across the 3 yr, whereas we observed significant declines in the abundance of Lasioglossum pilosum (Smith) and Eucera spp. trapped using blue vane traps during the project, suggesting local overtrapping of reproductive individuals. We conclude that blue vane traps are a useful tool for expanding insights into bee communities within orchard crop systems, but they should be used with great caution to avoid local extirpation of these important insects. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Measurement of radon daughters in air samples by alpha spectroscopy

    International Nuclear Information System (INIS)

    Acena, M.L.; Crespo, M.T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of polonium 214 and polonium 218. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter (Author)

  5. Sampling strategies for the analysis of reactive low-molecular weight compounds in air

    NARCIS (Netherlands)

    Henneken, H.

    2006-01-01

    Within this thesis, new sampling and analysis strategies for the determination of airborne workplace contaminants have been developed. Special focus has been directed towards the development of air sampling methods that involve diffusive sampling. In an introductory overview, the current

  6. Air Pollutant Emissions from Oil and Gas Production pads (Investigating Low Cost Passive Samplers)

    Science.gov (United States)

    To help achieve the goal of sustainable, environmentally responsible development of oil and gas resources, it isnecessary to understand the potential for air pollutant emissions from various extraction and production (E&P)processes at the upstream, wellpad level. Upstream oil and...

  7. A passive guard for low thermal conductivity measurement of small samples by the hot plate method

    International Nuclear Information System (INIS)

    Jannot, Yves; Godefroy, Justine; Degiovanni, Alain; Grigorova-Moutiers, Veneta

    2017-01-01

    Hot plate methods under steady state conditions are based on a 1D model to estimate the thermal conductivity, using measurements of the temperatures T 0 and T 1 of the two sides of the sample and of the heat flux crossing it. To be consistent with the hypothesis of the 1D heat flux, either a hot plate guarded apparatus is used, or the temperature is measured at the centre of the sample. On one hand the latter method can be used only if the ratio thickness/width of the sample is sufficiently low and on the other hand the guarded hot plate method requires large width samples (typical cross section of 0.6  ×  0.6 m 2 ). That is why both methods cannot be used for low width samples. The method presented in this paper is based on an optimal choice of the temperatures T 0 and T 1 compared to the ambient temperature T a , enabling the estimation of the thermal conductivity with a centered hot plate method, by applying the 1D heat flux model. It will be shown that these optimal values do not depend on the size or on the thermal conductivity of samples (in the range 0.015–0.2 W m −1 K −1 ), but only on T a . The experimental results obtained validate the method for several reference samples for values of the ratio thickness/width up to 0.3, thus enabling the measurement of the thermal conductivity of samples having a small cross-section, down to 0.045  ×  0.045 m 2 . (paper)

  8. Demonstration/Validation of the Snap Sampler Passive Ground Water Sampling Device

    Science.gov (United States)

    2011-06-01

    purging and sampling protocol. Analytes that were measured at the Pease site included total and dissolved concentrations of arsenic (As), calcium ...samples remain in the original bottle in which they were collected, presumably losses of volatiles and changes in concentrations of dissolved gases or...because of excavation and removal. This has resulted in hydraulically interconnected bedrock and overburden water- bearing zones in much of this area

  9. Efficacy of passive hair-traps for the genetic sampling of a low-density badger population

    Directory of Open Access Journals (Sweden)

    Alessandro Balestrieri

    2011-02-01

    Full Text Available

    A hair-trapping survey was carried out in the western River Po plain (NW Italy. We aimed to test whether barbed wire hair snares in combination with DNA profiling might represent an effective tool to study a low-density badger population. Traps were placed above the entrances of twelve badger setts between 15 February and 30 April 2010. Trapping effort was expressed as the number of trap-nights required to pluck a hair sample and the trend in the number of genotyped individual over time was analysed by regression analysis. Forty-three hair samples were collected, with an overall trapping effort of 54.8 trap-nights per one hair sample. Twenty-eight samples yielded reliable genotypes, allowing the identification of nine individual badgers. The length of storage period (1-3 months before DNA extraction did not seem to affect genotyping success. According to the regression model, trapping effort allowed to sample 75% of the overall population. Our results suggest that the efficacy of passive devices is affected by population density.

  10. Stratospheric Air Sub-sampler (SAS) and its application to analysis of Delta O-17(CO2) from small air samples collected with an AirCore

    NARCIS (Netherlands)

    Mrozek, Dorota Janina; van der Veen, Carina; Hofmann, Magdalena E. G.; Chen, Huilin; Kivi, Rigel; Heikkinen, Pauli; Rockmann, Thomas

    2016-01-01

    We present the set-up and a scientific application of the Stratospheric Air Sub-sampler (SAS), a device to collect and to store the vertical profile of air collected with an AirCore (Karion et al., 2010) in numerous sub-samples for later analysis in the laboratory. The SAS described here is a 20m

  11. Air-Stable Surface-Passivated Perovskite Quantum Dots for Ultra-Robust, Single- and Two-Photon-Induced Amplified Spontaneous Emission

    KAUST Repository

    Pan, Jun; Sarmah, Smritakshi P.; Banavoth, Murali; Dursun, Ibrahim; Peng, Wei; Parida, Manas R.; Liu, Jiakai; Sinatra, Lutfan; AlYami, Noktan; Zhao, Chao; Alarousu, Erkki; Ng, Tien Khee; Ooi, Boon S.; Bakr, Osman; Mohammed, Omar F.

    2015-01-01

    We demonstrate ultra-air- and photostable CsPbBr3 quantum dots (QDs) by using an inorganic–organic hybrid ion pair as the capping ligand. This passivation approach to perovskite QDs yields high photoluminescence quantum yield with unprecedented

  12. The determination of nitrogen dioxide in ambient air with free hanging filters as passive samplers, and a new calibration method using fritted bubblers

    NARCIS (Netherlands)

    Heeres, P.; Setiawan, R.; Krol, M.C.; Adema, E.H.

    2009-01-01

    This paper describes two new methods for the determination of NO2 in the ambient air. The first method consists of free hanging filters with a diameter of 2.5 cm as passive samplers. The filters are impregnated with triethanolamine to bind NO2. With standard colorimetrical analysis, the amount of

  13. Evaluating organochlorine pesticide residues in the aquatic environment of the Lake Naivasha River basin using passive sampling techniques.

    Science.gov (United States)

    Abbasi, Yasser; Mannaerts, Chris M

    2018-05-18

    Passive sampling techniques can improve the discovery of low concentrations by continuous collecting the contaminants, which usually go undetected with classic and once-off time-point grab sampling. The aim of this study was to evaluate organochlorine pesticide (OCP) residues in the aquatic environment of the Lake Naivasha river basin (Kenya) using passive sampling techniques. Silicone rubber sheet and Speedisk samplers were used to detect residues of α-HCH, β-HCH, γ-HCH, δ-HCH, heptachlor, aldrin, heptachlor epoxide, pp-DDE, endrin, dieldrin, α-endosulfan, β-endosulfan, pp-DDD, endrin aldehyde, pp-DDT, endosulfan sulfate, and methoxychlor in the Malewa River and Lake Naivasha. After solvent extraction from the sampling media, the residues were analyzed using gas chromatography electron capture detection (GC-ECD) for the OCPs and gas chromatography-mass spectrometry (GC-MS) for the PCB reference compounds. Measuring the OCP residues using the silicone rubber samplers revealed the highest concentration of residues (∑OCPs of 81 (± 18.9 SD) μg/L) to be at the Lake site, being the ultimate accumulation environment for surficial hydrological, chemical, and sediment transport through the river basin. The total OCP residue sums changed to 71.5 (± 11.3 SD) μg/L for the Middle Malewa and 59 (± 12.5 SD) μg/L for the Upper Malewa River sampling sites. The concentration sums of OCPs detected using the Speedisk samplers at the Upper Malewa, Middle Malewa, and the Lake Naivasha sites were 28.2 (± 4.2 SD), 31.3 (± 1.8 SD), and 34.2 (± 6.4 SD) μg/L, respectively. An evaluation of the different pesticide compound variations identified at the three sites revealed that endosulfan sulfate, α-HCH, methoxychlor, and endrin aldehyde residues were still found at all sampling sites. However, the statistical analysis of one-way ANOVA for testing the differences of ∑OCPs between the sampling sites for both the silicone rubber sheet and Speedisk samplers

  14. Passive sampling of selected endocrine disrupting compounds using polar organic chemical integrative samplers

    International Nuclear Information System (INIS)

    Arditsoglou, Anastasia; Voutsa, Dimitra

    2008-01-01

    Two types of polar organic chemical integrative samplers (pharmaceutical POCIS and pesticide POCIS) were examined for their sampling efficiency of selected endocrine disrupting compounds (EDCs). Laboratory-based calibration of POCISs was conducted by exposing them at high and low concentrations of 14 EDCs (4-alkyl-phenols, their ethoxylate oligomers, bisphenol A, selected estrogens and synthetic steroids) for different time periods. The kinetic studies showed an integrative uptake up to 28 days. The sampling rates for the individual compounds were obtained. The use of POCISs could result in an integrative approach to the quality status of the aquatic systems especially in the case of high variation of water concentrations of EDCs. The sampling efficiency of POCISs under various field conditions was assessed after their deployment in different aquatic environments. - Calibration and field performance of polar organic integrative samplers for monitoring EDCs in aquatic environments

  15. Comparison of techniques active and passive in measurement of radon concentration ("2"2"2Ra) in the air

    International Nuclear Information System (INIS)

    Oliveira, Evaldo Paulo de

    2017-01-01

    The purpose of this work was to perform a study comparing radon concentration measurements between two techniques used to measure radon gas in the air: one using LEXAN polycarbonate plastic detectors and the other the continuous monitor in AlphaGUARD passive mode. The concentrations of radon gas within radon emanation chambers were measured using calibrated / traceable sources generating "2"2"2Rn through "2"2"6Ra. In calibration the 'calibration factor' or 'sensitivity' was determined for the LEXAN plastic detector. The calibration work of the dosimeters was carried out at the Radon Laboratory of the Environmental Analysis Division - DIRAD IRD/CNEN and at the Natural Radioactivity Laboratory (LRN) of the Center for the Development of Nuclear Technology (CDTN/CNEN). The 'calibration factor' or 'sensitivity' was found to be 32.34 (traits.cm"-"2)/(kBq.d.m"-"3). This factor was used to determine the radon concentration measured by the LEXAN plastic detectors. Also in the calibration, the efficiencies for LEXAN (94.1% ± 9.7%) and AlphaGUARD (92.5% ± 7.2%) were determined. The statistical analysis used showed good parity in the results of the measurements. It was concluded that the results were satisfactory and will serve as a good reference for studies related to the radon air meters used in this work. (author)

  16. Concentrations, Trends, and Air-Water Exchange of PAHs and PBDEs Derived from Passive Samplers in Lake Superior in 2011.

    Science.gov (United States)

    Ruge, Zoe; Muir, Derek; Helm, Paul; Lohmann, Rainer

    2015-12-01

    Polycyclic aromatic hydrocarbons (PAHs) and polybrominated diphenylethers (PBDEs) are both currently released into the environment from anthropogenic activity. Both are hence primarily associated with populated or industrial areas, although wildfires can be an important source of PAHs, as well. Polyethylene passive samplers (PEs) were simultaneously deployed in surface water and near surface atmosphere to determine spatial trends and air-water gaseous exchange of 21 PAHs and 11 PBDEs at 19 sites across Lake Superior in 2011. Surface water and atmospheric PAH concentrations were greatest at urban sites (up to 65 ng L(-1) and 140 ng m(-3), respectively, averaged from June to October). Near populated regions, PAHs displayed net air-to-water deposition, but were near equilibrium off-shore. Retene, probably depositing following major wildfires in the region, dominated dissolved PAH concentrations at most Lake Superior sites. Atmospheric and dissolved PBDEs were greatest near urban and populated sites (up to 6.8 pg L(-1) and 15 pg m(-3), respectively, averaged from June to October), dominated by BDE-47. At most coastal sites, there was net gaseous deposition of BDE-47, with less brominated congeners contributing to Sault Ste. Marie and eastern open lake fluxes. Conversely, the central open lake and Eagle Harbor sites generally displayed volatilization of PBDEs into the atmosphere, mainly BDE-47.

  17. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...

  18. Working parameters affecting earth-air heat exchanger (EAHE) system performance for passive cooling: A review

    Science.gov (United States)

    Darius, D.; Misaran, M. S.; Rahman, Md. M.; Ismail, M. A.; Amaludin, A.

    2017-07-01

    The study on the effect of the working parameters such as pipe material, pipe length, pipe diameter, depth of burial of the pipe, air flow rate and different types of soils on the thermal performance of earth-air heat exchanger (EAHE) systems is very crucial to ensure that thermal comfort can be achieved. In the past decade, researchers have performed studies to develop numerical models for analysis of EAHE systems. Until recently, two-dimensional models replaced the numerical models in the 1990s and in recent times, more advanced analysis using three-dimensional models, specifically the Computational Fluid Dynamics (CFD) simulation in the analysis of EAHE system. This paper reviews previous models used to analyse the EAHE system and working parameters that affects the earth-air heat exchanger (EAHE) thermal performance as of February 2017. Recent findings on the parameters affecting EAHE performance are also presented and discussed. As a conclusion, with the advent of CFD methods, investigational work have geared up to modelling and simulation work as it saves time and cost. Comprehension of the EAHE working parameters and its effect on system performance is largely established. However, the study on type of soil and its characteristics on the performance of EAHEs systems are surprisingly barren. Therefore, future studies should focus on the effect of soil characteristics such as moisture content, density of soil, and type of soil on the thermal performance of EAHEs system.

  19. Passive sampling in regulatory chemical monitoring of nonpolar organic compounds in the aquatic environment

    NARCIS (Netherlands)

    Booij, K.; Robinson, C.D.; Burgess, R.M.; Mayer, P.; Roberts, C.A.; Ahrens, L.; Allan, I.J.; Brant, J.; Jones, L.; Kraus, U.R.; Larsen, M.M.; Lepom, P.; Petersen, J.; Pröfrock, D.; Roose, P.; Schäfer, S.; Smedes, F.; Tixier, C.; Vorkamp, K.; Whitehouse, P.

    2016-01-01

    We reviewed compliance monitoring requirements in the EuropeanUnion, the United States, and the Oslo-Paris Convention for the protection of themarine environment of the North-East Atlantic, and evaluated if these are met bypassive sampling methods for nonpolar compounds. The strengths

  20. An unattended device for high-voltage sampling and passive measurement of thoron decay products

    Energy Technology Data Exchange (ETDEWEB)

    Gierl, Stefanie; Meisenberg, Oliver, E-mail: oliver.meisenberg@helmholtz-muenchen.de; Wielunski, Marek; Tschiersch, Jochen [Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstr. 1, 85764 Neuherberg (Germany); Haninger, Thomas [Helmholtz Zentrum München, German Research Center for Environmental Health, Auswertungsstelle für Strahlendosimeter, Otto-Hahn-Ring 6, 81739 München (Germany)

    2014-02-15

    An integrating measurement device for the concentration of airborne thoron decay products was designed and calibrated. It is suitable for unattended use over up to several months also in inhabited dwellings. The device consists of a hemispheric capacitor with a wire mesh as the outer electrode on ground potential and the sampling substrates as the inner electrode on +7.0 kV. Negatively charged and neutral thoron decay products are accelerated to and deposited on the sampling substrates. As sampling substrates, CR39 solid-state nuclear track detectors are used in order to record the alpha decay of the sampled decay products. Nuclide discrimination is achieved by covering the detectors with aluminum foil of different thickness, which are penetrated only by alpha particles with sufficient energy. Devices of this type were calibrated against working level monitors in a thoron experimental house. The sensitivity was measured as 9.2 tracks per Bq/m{sup 3} × d of thoron decay products. The devices were used over 8 weeks in several houses built of earthen material in southern Germany, where equilibrium equivalent concentrations of 1.4–9.9 Bq/m{sup 3} of thoron decay products were measured.

  1. Molecular Biological Characterization of Air Samples: A Survey of Four Strategically Important Regions

    National Research Council Canada - National Science Library

    Francesconi, Stephen

    2003-01-01

    .... In support of this requirement, the Joint Program Office for Biological Defense initiated an aggressive program incorporating the development of air-sampling and agent detecting devices, coined...

  2. Passive air exchanges between building and urban canyon via openings in a single facade

    International Nuclear Information System (INIS)

    Syrios, K.; Hunt, G.R.

    2008-01-01

    The results of an experimental study examining the steady exchange of air and heat between a building and an urban canyon are presented. The focus is on the effect of the canyon aspect ratio on the airflow through openings made exclusively in one side of the building. The interaction of the external wind flow and the internal thermally-driven flow was shown to depend upon the ratio of the building height H b to the canyon width W (distance between buildings forming the canyons). The trends observed as this aspect ratio (H b /W) was varied allow for identification of canyon geometries that yield reduced or enhanced building ventilation airflow rates

  3. DGT Passive Sampling for Quantitative in Situ Measurements of Compounds from Household and Personal Care Products in Waters.

    Science.gov (United States)

    Chen, Wei; Li, Yanying; Chen, Chang-Er; Sweetman, Andrew J; Zhang, Hao; Jones, Kevin C

    2017-11-21

    Widespread use of organic chemicals in household and personal care products (HPCPs) and their discharge into aquatic systems means reliable, robust techniques to monitor environmental concentrations are needed. The passive sampling approach of diffusive gradients in thin-films (DGT) is developed here and demonstrated to provide in situ quantitative and time-weighted average (TWA) measurement of these chemicals in waters. The novel technique is developed for HPCPs, including preservatives, antioxidants and disinfectants, by evaluating the performance of different binding agents. Ultrasonic extraction of binding gels in acetonitrile gave good and consistent recoveries for all test chemicals. Uptake by DGT with HLB (hydrophilic-lipophilic-balanced) as the binding agent was relatively independent of pH (3.5-9.5), ionic strength (0.001-0.1 M) and dissolved organic matter (0-20 mg L -1 ), making it suitable for applications across a wide range of environments. Deployment time and diffusion layer thickness dependence experiments confirmed DGT accumulated chemicals masses are consistent with theoretical predictions. The technique was further tested and applied in the influent and effluent of a wastewater treatment plant. Results were compared with conventional grab-sampling and 24-h-composited samples from autosamplers. DGT provided TWA concentrations over up to 18 days deployment, with minimal effects from biofouling or the diffusive boundary layer. The field application demonstrated advantages of the DGT technique: it gives in situ analyte preconcentration in a simple matrix, with more quantitative measurement of the HPCP analytes.

  4. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Science.gov (United States)

    2010-07-01

    ... ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA processing... determination within 20 workdays, we have instituted multitrack processing of requests. Based on the information... source; responsive records were part of the Air Force's decision-making process, and the prerelease...

  5. A passive brain-computer interface application for the mental workload assessment on professional air traffic controllers during realistic air traffic control tasks.

    Science.gov (United States)

    Aricò, P; Borghini, G; Di Flumeri, G; Colosimo, A; Pozzi, S; Babiloni, F

    2016-01-01

    In the last decades, it has been a fast-growing concept in the neuroscience field. The passive brain-computer interface (p-BCI) systems allow to improve the human-machine interaction (HMI) in operational environments, by using the covert brain activity (eg, mental workload) of the operator. However, p-BCI technology could suffer from some practical issues when used outside the laboratories. In particular, one of the most important limitations is the necessity to recalibrate the p-BCI system each time before its use, to avoid a significant reduction of its reliability in the detection of the considered mental states. The objective of the proposed study was to provide an example of p-BCIs used to evaluate the users' mental workload in a real operational environment. For this purpose, through the facilities provided by the École Nationale de l'Aviation Civile of Toulouse (France), the cerebral activity of 12 professional air traffic control officers (ATCOs) has been recorded while performing high realistic air traffic management scenarios. By the analysis of the ATCOs' brain activity (electroencephalographic signal-EEG) and the subjective workload perception (instantaneous self-assessment) provided by both the examined ATCOs and external air traffic control experts, it has been possible to estimate and evaluate the variation of the mental workload under which the controllers were operating. The results showed (i) a high significant correlation between the neurophysiological and the subjective workload assessment, and (ii) a high reliability over time (up to a month) of the proposed algorithm that was also able to maintain high discrimination accuracies by using a low number of EEG electrodes (~3 EEG channels). In conclusion, the proposed methodology demonstrated the suitability of p-BCI systems in operational environments and the advantages of the neurophysiological measures with respect to the subjective ones. © 2016 Elsevier B.V. All rights reserved.

  6. Development of activated charcoal impregnated air sampling filter media : their characteristics and use

    International Nuclear Information System (INIS)

    Khan, A.A.; Ramarathinam, K.; Gupta, S.K.; Deshingkar, D.S.; Kishore, A.G.

    1975-01-01

    Because of its low maximum permissible concentration in air, air-borne radioiodine must be accurately monitored in contaminated air streams, in the working environment and handling facilities, before release to the environment from the nuclear facilities. Activated charcoal impregnated air sampling filter media are found to be most suitable for monitoring airborne iodine-131. Because of its simplicity and reproducible nature in assessment of air-borne radioactive iodine, the work on the development of such media was undertaken in order to find a suitable substitute for imported activated charcoal impregnated air sampling filter media. Eight different media of such type were developed, evaluated and compared with two imported media. Best suitable medium is recommended for its use in air-borne iodine sampling which was found to be even better suited than imported media of such type. (author)

  7. Predicting bioavailability of PAHs in field-contaminated soils by passive sampling with triolein embedded cellulose acetate membranes

    Energy Technology Data Exchange (ETDEWEB)

    Tao Yuqiang [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Zhang Shuzhen [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China)], E-mail: szzhang@rcees.ac.cn; Wang Zijian [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Christie, Peter [Queen' s University Belfast, Agricultural and Environmental Science Department, Newforge Lane, Belfast BT9 5PX (United Kingdom)

    2009-02-15

    Triolein embedded cellulose acetate membrane (TECAM) was used for passive sampling of the fraction of naphthalene, phenanthrene, pyrene and benzo[a]pyrene in 18 field-contaminated soils. The sampling process of PAHs by TECAM fitted well with a first-order kinetics model and PAHs reached 95% of equilibrium in TECAM within 20 h. Concentrations of PAHs in TECAM (C{sub TECAM}) correlated well with the concentrations in soils (r{sup 2} = 0.693-0.962, p < 0.001). Furthermore, concentrations of PAHs determined in the soil solution were very close to the values estimated by C{sub TECAM} and the partition coefficient between TECAM and water (K{sub TECAM-w}). After lipid normalization nearly 1:1 relationships were observed between PAH concentrations in TECAMs and earthworms exposed to the soils (r{sup 2} = 0.591-0.824, n = 18, p < 0.01). These results suggest that TECAM can be a useful tool to predict bioavailability of PAHs in field-contaminated soils. - Triolein embedded cellulose acetate membranes can be a useful tool to predict bioavailability of PAHs in field-contaminated soils.

  8. Technical assessment of compliance with work place air sampling requirements at T Plant. Revision No. 1

    International Nuclear Information System (INIS)

    Hackworth, M.F.

    1995-01-01

    The US DOE requires its contractors to conduct air sampling to detect and evaluate airborne radioactive material in the workplace. Hanford Reservation T Plant compliance with workplace air sampling requirements has been assessed. Requirements, basis for determining compliance and recommendations are included

  9. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    Science.gov (United States)

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (pair space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (ptransport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (ptransport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Directional passive ambient air monitoring of ammonia for fugitive source attribution; a field trial with wind tunnel characteristics

    Science.gov (United States)

    Solera García, M. A.; Timmis, R. J.; Van Dijk, N.; Whyatt, J. D.; Leith, I. D.; Leeson, S. R.; Braban, C. F.; Sheppard, L. J.; Sutton, M. A.; Tang, Y. S.

    2017-10-01

    Atmospheric ammonia is a precursor for secondary particulate matter formation, which harms human health and contributes to acidification and eutrophication. Under the 2012 Gothenburg Protocol, 2005 emissions must be cut by 6% by 2020. In the UK, 83% of total emissions originate from agricultural practices such as fertilizer use and rearing of livestock, with emissions that are spatially extensive and variable in nature. Such fugitive emissions make resolving and tracking of individual site performance challenging. The Directional Passive Air quality Sampler (DPAS) was trialled at Whim Bog, an experimental site with a wind-controlled artificial release of ammonia, in combination with CEH-developed ammonia samplers. Whilst saturation issues were identified, two DPAS-MANDE (Mini Annular Denuder) systems, when deployed in parallel, displayed an average relative deviation of 15% (2-54%) across all 12 directions, with the directions exposed to the ammonia source showing ∼5% difference. The DPAS-MANDE has shown great potential for directional discrimination and can contribute to the understanding and management of fugitive ammonia sources from intensive agriculture sites.

  11. Comparison of lichen, conifer needles, passive air sampling devices, and snowpack as passive sampling media to measure semi-volatile organic compounds in remote atmospheres

    Science.gov (United States)

    The impact of extensively used arsenic-containing herbicides on groundwater beneath golf courses has become a topic of interest. Although currently used organoarsenicals are less toxic, their application into the environment may produce the more toxic inorganic arsenicals. The ob...

  12. Spatial trends, sources, and air-water exchange of organochlorine pesticides in the Great Lakes basin using low density polyethylene passive samplers.

    Science.gov (United States)

    Khairy, Mohammed; Muir, Derek; Teixeira, Camilla; Lohmann, Rainer

    2014-08-19

    Polyethylene passive samplers were deployed during summer and fall of 2011 in the lower Great Lakes to assess the spatial distribution and sources of gaseous and freely dissolved organochlorine pesticides (OCPs) and their air-water exchange. Average gaseous OCP concentrations ranged from nondetect to 133 pg/m(3). Gaseous concentrations of hexachlorobenzene, dieldrin, and chlordanes were significantly greater (Mann-Whitney test, p < 0.05) at Lake Erie than Lake Ontario. A multiple linear regression implied that both cropland and urban areas within 50 and 10 km buffer zones, respectively, were critical parameters to explain the total variability in atmospheric concentrations. Freely dissolved OCP concentrations (nondetect to 114 pg/L) were lower than previously reported. Aqueous half-lives generally ranged from 1.7 to 6.7 years. Nonetheless, concentrations of p,p'-DDE and chlordanes were higher than New York State Ambient Water Quality Standards for the protection of human health from the consumption of fish. Spatial distributions of freely dissolved OCPs in both lakes were influenced by loadings from areas of concern and the water circulation patterns. Flux calculations indicated net deposition of γ-hexachlorocyclohexane, heptachlor-epoxide, and α- and β-endosulfan (-0.02 to -33 ng/m(2)/day) and net volatilization of heptachlor, aldrin, trans-chlordane, and trans-nonachlor (0.0 to 9.0 ng/m(2)/day) in most samples.

  13. Distribution of Gas Phase Polycyclic Aromatic Hydrocarbons (PAHs in Selected Indoor and Outdoor Air Samples of Malaysia: a Case Study in Serdang, Selangor and Bachang, Malacca

    Directory of Open Access Journals (Sweden)

    Haris Hafizal Abd Hamid

    2017-07-01

    Full Text Available Distribution of 10 polycyclic aromatic hydrocarbons (PAHs in the gas phase of air from selected indoor and outdoor areas of Selangor and Malacca, Malaysia has been investigated. A locally designed Semi Permeable Membrane Device (SPMD was applied for passive air sampling for 37 days at selected locations. Cleanup was carried out with Gas Purge - Micro Syringe Extraction (GP-MSE and the final analysis was using Gas Chromatography-Mass Spectrometry (GC-MS. In this study, 6 indoor and 12 outdoor locations were selected for air sampling. A total of 10 compounds of PAHs (Ʃ10PAHs were determined in the range of 0.218 ng/m3 - 1.692 ng/m3 and 0.378 ng/m3 - 1.492 ng/m3 in outdoor and indoor samples respectively. In the outdoor samples, locations such as near a petrol station and heavy traffic showed the maximum levels of Ʃ10PAHs, while rooftop samples showed the lowest Ʃ10PAHs. The distribution of gas phase Ʃ10PAHs was influenced by vehicular emission. Low molecular weight (LMW compounds (2-3 rings were dominant in all samples (>70% indicating that SPMD has successfully sampled the gas phase of the air.

  14. Sampling and preparation of air pollutants at the Coal Paiton Power Plant area Probolinggo

    International Nuclear Information System (INIS)

    Iswantoro; Sutanto, W.W

    2013-01-01

    Sampling has been conducted on April 8 th to 18 th, 2012 at the plant area of Paiton Coal Power Plant using e-sampler for particulated matter PM-2,5 and PM-10, high volume air sampler for total suspended particulate (TSP) at the three sampling locations as the representative pollution. Filter before and after sampling was weighed and extremely guarded contamination. Air filters stored in desiccator filter for 24 hours. Determination of concentration of ambient air pollutants conducted by gravimetric method derived from a reduction in weight the samples on the filter PM-2,5; PM-10 and TSP to the weight of the empty filter. (author)

  15. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR

    Science.gov (United States)

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample ...

  16. Ethylene vinyl acetate polymer as a tool for passive sampling monitoring of hydrophobic chemicals in the salmon farm industry

    International Nuclear Information System (INIS)

    Tucca, Felipe; Moya, Heriberto; Barra, Ricardo

    2014-01-01

    Highlights: • The samplers allow the detection of hydrophobic chemicals in the marine environment. • The samplers reach equilibrium quickly, with days of deployment in the field. • The samplers have low costs and easy manipulation for monitoring programs. • A way to collect chemicals in the aquatic environment without human effort. - Abstract: Current monitoring programs are focused on hydrophobic chemicals detection in aquatic systems, which require the collection of high volumes of water samples at a given time. The present study documents the preliminary use of the polymer ethylene vinyl acetate (EVA) as a passive sampler for the detection of a hydrophobic chemical used by salmon industries such as cypermethrin. Initially, an experimental calibration in laboratory was performed to determine the cypermethrin equilibrium between sampler and aquatic medium, which was reached after seven days of exposure. A logarithm of partitioning coefficient EVA–water (log K EVA–W ) of 5.6 was reported. Field deployment of EVA samplers demonstrated average concentrations of cypermethrin in water to be 2.07 ± 0.7 ng L −1 close to salmon cages, while near-shore was 4.39 ± 0.8 ng L −1 . This was a first approach for assessing EVA samplers design as a tool of monitoring in water for areas with salmon farming activity

  17. Atmospheric concentrations and trends of poly- and perfluoroalkyl substances (PFAS) and volatile methyl siloxanes (VMS) over 7 years of sampling in the Global Atmospheric Passive Sampling (GAPS) network.

    Science.gov (United States)

    Rauert, Cassandra; Shoieb, Mahiba; Schuster, Jasmin K; Eng, Anita; Harner, Tom

    2018-07-01

    Poly- and per-fluoroalkyl substances (PFAS) and volatile methyl siloxanes (VMS) were monitored at 21 sites in the Global Atmospheric Passive Sampling (GAPS) Network. Atmospheric concentrations previously reported from 2009 were compared to concentrations measured at these sites in 2013 and 2015, to assess trends over 7 years of monitoring. Concentrations of the fluorotelomer alcohols (FTOHs) and fluorinated sulfonamides and sulfonamidoethanols (FOSAs and FOSEs) were stable at these sites from 2009 to 2015 with no significant difference (p > 0.05) in concentrations. Elevated concentrations of all the neutral PFAS were detected at the urban sites as compared to the polar/background sites. The perfluorosulfonic acids (PFSAs), meanwhile, saw a significant increase (p  0.05). Concentrations of the PFSAs and the PFCAs were similar at all location types, showing the global reach of these persistent compounds. Concentrations of the cyclic VMS (cVMS) were at least an order of magnitude higher than the linear VMS (lVMS) and the PFAS. Octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5) and dodecamethylcyclohexasiloxane (D6) saw a weak significant increase in concentrations from 2009 to 2013 (p < 0.05), however, hexamethylcyclotrisiloxane (D3) had a strong significant decrease in concentrations from 2009 to 2015 (p < 0.01). Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Time integrated Pesticide analysis in the tropical Rio Tapezco in Costa Rica by using passive sampling approaches

    Science.gov (United States)

    Weiss, Frederik; Stamm, Christian; Ruepert, Clemens; Zurbrügg, Christian; Eggen, Rik

    2016-04-01

    Tropical areas are pesticide "hot spots". Global data indicate that in these regions the annual average pesticide application rates and surface runoff potentials can be very high. However in tropical regions, information about the pesticide entry routes, their environmental behavior, and the degree of water pollution is often lacking. Catchment-scale monitoring data are required to fill these knowledge gaps and to gain a better systematic understanding of the environmental fate, behavior and impacts of pesticides in tropical aquatic environments. Accordingly, our study was conducted in the tropical Rio Tapezco catchment in the Zarcero canton, Costa Rica. The area covers 5112 ha, ranges between an altitude of 1580 and 2010 m above sea level and receives a total annual precipitation between 1500 and 3500 mm. The catchment is intensively used for the horticultural production of vegetables and herbs. It is a hot spots of pesticide use with an average application rate of about 22 kg/ha of arable land and cropping cycle. In conjunction with the poor pesticide application practices, the tropical climate, strong precipitations and the continuous pesticide application during the whole year, the risks for water pollution and environmental health are high. Indeed, previous spot sampling showed that in streams of the study area, several pesticides were found in concentrations up to 6.8 μg/L. While this data indicate the risk for the aquatic environment, the seasonal grab sampling reflects only poorly the highly dynamic concentration time-series. Additionally, the assessment of the actual pollution level was restricted by a limited analytical window. To close these research gaps, we sampled the rivers of the study area continuously between end of July and beginning of October 2015 by using three passive sampling systems (Camcather® with styrene-divinylbenzene reverse phase sulfonated discs, polydimethylsiloxane sheets, and a water level proportional water sampler). Samples

  19. Sample and injection manifolds used to in-place test of nuclear air-cleaning system

    International Nuclear Information System (INIS)

    Qiu Dangui; Li Xinzhi; Hou Jianrong; Qiao Taifei; Wu Tao; Zhang Jirong; Han Lihong

    2012-01-01

    Objective: According to the regulations of nuclear safety rules and related standards, in-place test of the nuclear air-cleaning systems should be carried out before and during operation of the nuclear facilities, which ensure them to be in good condition. In some special conditions, the use of sample and injection manifolds is required to make the test tracer and ventilating duct air fully mixed, so as to get the on-spot typical sample. Methods: This paper introduces the technology and application of the sample and injection manifolds in nuclear air-cleaning system. Results: Multi point injection and multi point sampling technology as an effective experimental method, has been used in a of domestic and international nuclear facilities. Conclusion: The technology solved the problem of uniformly of on-spot injection and sampling,which plays an important role in objectively evaluating the function of nuclear air-cleaning system. (authors)

  20. Air sampling by pumping through a filter: effects of air flow rate, concentration, and decay of airborne substances

    OpenAIRE

    Šoštarić, Marko; Petrinec, Branko; Babić, Dinko

    2016-01-01

    This paper tackles the issue of interpreting the number of airborne particles adsorbed on a filter through which a certain volume of sampled air has been pumped. This number is equal to the product of the pumped volume and particle concentration in air, but only if the concentration is constant over time and if there is no substance decomposition on the filter during sampling. If this is not the case, one must take into account the inconstancy of the concentration and the decay law for a give...

  1. [The investigation of control mechanisms of stepping rhythm in human in the air-stepping conditions during passive and voluntary leg movements].

    Science.gov (United States)

    Solopova, I A; Selionon, V A; Grishin, A A

    2010-01-01

    influences from moving leg in the most degree then on central commands. It seems that afferent inputs from pressure receptors of foot in the condition of "air-stepping" actively interact with central program of stepping and, irrespective of type of the performing movements (voluntary or passive), form the final pattern activity.

  2. Toxic air pollutants notice of construction for rotary mode core sampling systems three and four and modification system two

    International Nuclear Information System (INIS)

    Dyekman, D.L.

    1998-01-01

    The Washington State Department of Ecology (Ecology) approved the construction and operation of Rotary Mode Core Sampling (RMCS) System Two on November 22, 1993 (NOC-93-04). This approval supported the characterization of waste in the single-shell tanks (SSTS) and double-shell tanks (DSTS) on the Hanford Site. The waste tank characterization sampling and analysis effort is vital to the safe operations of the Hanford Site tank farms, and the timely collection of the information necessary to support retrieval, pretreatment, disposal planning, and final closure strategy. This is based on the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 93-05 Implementation Plan (DOE-RL-94-001), US Department of Energy, Richland Operations Office (DOE-RL) proposed the expedited construction and operation of two additional RMCS systems to support characterization of waste stored in SSTs and DSTS. RMCS currently is scheduled for approximately 50 (active or passively ventilated) of the 149 SSTs in the 200 East and 200 West Areas. If necessary, the RMCS will be used to sample other tanks currently not scheduled, subject to the requirements of this document and any applicable Ecology approval order. The typical components of the RMCS systems are shown in Figure 1. It should be noted that the Flammable Gas Detector cart is not being used during RMCS at this time. RMCS is scheduled for approximately 40 tanks that are not actively ventilated. These tanks operate at atmospheric pressure with passive (breather) high-efficiency particulate air (HEPA) filters. The RMCS system uses nitrogen gas to cool and purge the drill bit assembly. Without the use of a portable ventilation system, the additional gas from RMCS might unsafely pressurize tanks that are not actively ventilated. The RMCS system also will generate aerosols and dust in the tank vapor head space. HEPA filters will be required on the portable exhauster during rotary mode core drilling to control radionuclide

  3. Gas-chromatographic quantitative determination of argon in air samples, by elimination of oxigen

    International Nuclear Information System (INIS)

    Sofronie, E.

    1982-08-01

    A method of gas-chromatographic quantitative determination of argon in air samples, by elimination of oxygen, is presented. Experiments were carried out in a static system. Conditions for the application of the method in dynamic systems are specified. Sensibility of the method: 5 10 -4 cm 3 Ar per cm 3 of air. (author)

  4. Spot the difference. Impact of different selection criteria on observed properties of passive galaxies in zCOSMOS-20k sample

    Science.gov (United States)

    Moresco, M.; Pozzetti, L.; Cimatti, A.; Zamorani, G.; Bolzonella, M.; Lamareille, F.; Mignoli, M.; Zucca, E.; Lilly, S. J.; Carollo, C. M.; Contini, T.; Kneib, J.-P.; Le Fèvre, O.; Mainieri, V.; Renzini, A.; Scodeggio, M.; Bardelli, S.; Bongiorno, A.; Caputi, K.; Cucciati, O.; de la Torre, S.; de Ravel, L.; Franzetti, P.; Garilli, B.; Iovino, A.; Kampczyk, P.; Knobel, C.; Kovač, K.; Le Borgne, J.-F.; Le Brun, V.; Maier, C.; Pelló, R.; Peng, Y.; Perez-Montero, E.; Presotto, V.; Silverman, J. D.; Tanaka, M.; Tasca, L.; Tresse, L.; Vergani, D.; Barnes, L.; Bordoloi, R.; Cappi, A.; Diener, C.; Koekemoer, A. M.; Le Floc'h, E.; López-Sanjuan, C.; McCracken, H. J.; Nair, P.; Oesch, P.; Scarlata, C.; Scoville, N.; Welikala, N.

    2013-10-01

    Aims: We present the analysis of photometric, spectroscopic, and morphological properties for differently selected samples of passive galaxies up to z = 1 extracted from the zCOSMOS-20k spectroscopic survey. This analysis intends toexplore the dependence of galaxy properties on the selection criterion adopted, study the degree of contamination due to star-forming outliers, and provide a comparison between different commonly used selection criteria. This work is a first step to fully investigating the selection effects of passive galaxies for future massive surveys such as Euclid. Methods: We extracted from the zCOSMOS-20k catalog six different samples of passive galaxies, based on morphology (3336 "morphological" early-type galaxies), optical colors (4889 "red-sequence" galaxies and 4882 "red UVJ" galaxies), specific star-formation rate (2937 "quiescent" galaxies), a best fit to the observed spectral energy distribution (2603 "red SED" galaxies), and a criterion that combines morphological, spectroscopic, and photometric information (1530 "red & passive early-type galaxies"). For all the samples, we studied optical and infrared colors, morphological properties, specific star-formation rates (SFRs), and the equivalent widths of the residual emission lines; this analysis was performed as a function of redshift and stellar mass to inspect further possible dependencies. Results: We find that each passive galaxy sample displays a certain level of contamination due to blue/star-forming/nonpassive outliers. The morphological sample is the one that presents the higher percentage of contamination, with ~12-65% (depending on the mass range) of galaxies not located in the red sequence, ~25-80% of galaxies with a specific SFR up to ~25 times higher than the adopted definition of passive, and significant emission lines found in the median stacked spectra, at least for log (M/M⊙) contamination in color 10.25, very limited tails in sSFR, a median value ~20% higher than the

  5. Mixed species radioiodine air sampling readout and dose assessment system

    International Nuclear Information System (INIS)

    Distenfeld, C.H.; Klemish, J.R. Jr.

    1978-01-01

    This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector

  6. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    Science.gov (United States)

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration.

  7. Elemental analysis of air particulate samples in Jakarta area by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Yumiarti; Yusuf, M.; Mellawati, June; Menry, Yulizon; Surtipanti S

    1998-01-01

    Determination of elements in air particulate samples collected from Jakarta, especially from industrial area Pulo Gadung, also from residence, office, and recreation sites had been carried out. The samples collected periodically from August through December 1996. The elements were analyzed by X-ray fluorescence spectrometry method. Quantitative and qualitative analyses were done using QXAS AXIL (Quantitative X-ray Analysis System of x-ray Spectra by Iterative Least squares fitting) and QAES (Quantitative Analyses of Environmental Samples) package program. Results of the analyses showed that the content of heavy metal elements in air particulate samples from all areas studied were still below the maximum permissible concentration. (authors)

  8. Passive house progress report: Energy and indoor air quality. Measuring methods and verification of energy saving potentials and indoor air quality in passive houses at Nuremberg; Passivhaus-Projektbericht: Energie und Raumluftqualitaet. Messetchnische Evaluierung und Verifizierung der energetischen Einsparpotentiale und Raumluftqualitaet an Passivhaeusern in Nuernberg. Projekt: Passiv-Haus-Doppelhaeuser, Wachtelstrasse 12/Praelat-Nicol-Strasse 3-7, Nuernberg-Wetzendorf

    Energy Technology Data Exchange (ETDEWEB)

    Schulze Darup, B [ed.

    2002-07-01

    A model passive building was constructed at Nuremberg. Buildings of this type have an annual heat consumption of less than 15 kWh/m{sup 2}, so that quality assurance is of utmost importance with regard to energy consumption, primary energy balance, environmental impact and especially room air quality. The findings of the project will be published. [German] Im Rahmen der Lokalen Agenda 21 wurde in Nuernberg ein Passivhaus-Modellprojekt erstellt. Da energiesparende Wohngebaeude mit einem jaehrlichen Heizwaermebedarf unter 15 kWh/m{sup 2} zunehmend zum Stand der Technik werden, ist eine grundlegende Qualitaetssicherung hinsichtlich Energieverbrauch, Primaerenergiebilanz, Umweltvertraeglichkeit und insbesondere Raumluftqualitaet sowie die Veroeffentlichung der Erfahrungen von grosser Bedeutung. (orig.)

  9. Enhanced active aluminum content and thermal behaviour of nano-aluminum particles passivated during synthesis using thermal plasma route

    International Nuclear Information System (INIS)

    Mathe, Vikas L.; Varma, Vijay; Raut, Suyog; Nandi, Amiya Kumar; Pant, Arti; Prasanth, Hima; Pandey, R.K.; Bhoraskar, Sudha V.; Das, Asoka K.

    2016-01-01

    Graphical abstract: - Highlights: • Synthesis of nano crystalline Al (nAl) using DC thermal plasma reactor. • In situ passivation of nAl by palmitic acid and air. • Enhanced active aluminum content obtained for palmitic acid passivated nAl. • Palmitic acid passivated nAl are quite stable in humid atmospheres. - Abstract: Here, we report synthesis and in situ passivation of aluminum nanoparticles using thermal plasma reactor. Both air and palmitc acid passivation was carried out during the synthesis in the thermal plasma reactor. The passivated nanoparticles have been characterized for their structural and morphological properties using X-ray diffraction (XRD) and transmission electron microscopy (TEM) techniques. In order to understand nature of passivation vibrational spectroscopic analysis have been carried out. The enhancement in active aluminum content and shelf life for a palmitic acid passivated nano-aluminum particles in comparison to the air passivated samples and commercially available nano Al powder (ALEX) has been observed. Thermo-gravimetric analysis was used to estimate active aluminum content of all the samples under investigation. In addition cerimetric back titration method was also used to estimate AAC and the shelf life of passivated aluminum particles. Structural, microstructural and thermogravomateric analysis of four year aged passivated sample also depicts effectiveness of palmitic acid passivation.

  10. Enhanced active aluminum content and thermal behaviour of nano-aluminum particles passivated during synthesis using thermal plasma route

    Energy Technology Data Exchange (ETDEWEB)

    Mathe, Vikas L., E-mail: vlmathe@physics.unipune.ac.in [Department of Physics, Savitribai Phule Pune University, Pune 411007, Maharashtra (India); Varma, Vijay; Raut, Suyog [Department of Physics, Savitribai Phule Pune University, Pune 411007, Maharashtra (India); Nandi, Amiya Kumar; Pant, Arti; Prasanth, Hima; Pandey, R.K. [High Energy Materials Research Lab, Sutarwadi, Pune 411021, Maharashtra (India); Bhoraskar, Sudha V. [Department of Physics, Savitribai Phule Pune University, Pune 411007, Maharashtra (India); Das, Asoka K. [Utkal University, VaniVihar, Bhubaneswar, Odisha 751004 (India)

    2016-04-15

    Graphical abstract: - Highlights: • Synthesis of nano crystalline Al (nAl) using DC thermal plasma reactor. • In situ passivation of nAl by palmitic acid and air. • Enhanced active aluminum content obtained for palmitic acid passivated nAl. • Palmitic acid passivated nAl are quite stable in humid atmospheres. - Abstract: Here, we report synthesis and in situ passivation of aluminum nanoparticles using thermal plasma reactor. Both air and palmitc acid passivation was carried out during the synthesis in the thermal plasma reactor. The passivated nanoparticles have been characterized for their structural and morphological properties using X-ray diffraction (XRD) and transmission electron microscopy (TEM) techniques. In order to understand nature of passivation vibrational spectroscopic analysis have been carried out. The enhancement in active aluminum content and shelf life for a palmitic acid passivated nano-aluminum particles in comparison to the air passivated samples and commercially available nano Al powder (ALEX) has been observed. Thermo-gravimetric analysis was used to estimate active aluminum content of all the samples under investigation. In addition cerimetric back titration method was also used to estimate AAC and the shelf life of passivated aluminum particles. Structural, microstructural and thermogravomateric analysis of four year aged passivated sample also depicts effectiveness of palmitic acid passivation.

  11. Fabrication and characterization of buckypapers for use in air sampling

    Science.gov (United States)

    Oh, Jonghwa

    Occupational exposure to volatile organic compounds (VOCs) is a concern from a public health perspective. In many industrial activities, workers' exposure to VOCs can be sufficiently high to induce adverse health effects, so their monitoring is necessary. In exposure assessment, post sampling extraction and quantification are the typical analytical procedures. Recently, our group developed the photothermal desorption (PTD) technique in which a pulse of light thermally desorbs an analyte directly from a sorbent. Advantages of this technique are; it is solvent free, repeated analysis is possible, sorbents are reusable, and no high cost of equipment is required. PTD overcomes almost all drawbacks of current extraction methods. This study was aimed to develop and test a new sorbent which will efficiently work with PTD. Single-walled carbon nanotubes (SWNTs) were examined as potential sorbents because of their high surface area, great thermal conductivity, and efficient light absorption. SWNTs were fabricated into a self-supporting form (i.e., buckypaper (BP)) which will preserve its physical integrity under normal working conditions. Largely two types of SWNTs were used, arc discharge (AD) and high-pressure carbon monoxide (HiPco), and different fabrication methods were examined. Upon fabrication, their adsorption properties were characterized in terms of Brunauer, Emmett, and Teller (BET) surface area, pore size, and toluene adsorption capacity. HiPco BP and methanol-cleaned AD BP (suspended/rinsed with methanol) were the top two materials, showing the highest surface area (649 and 387 m²/g, respectively) and adsorption capacity (106 and 46 mg/g, respectively) with relatively small mean pore diameter (7.7 and 8.8 nm, respectively). To further improve the adsorption properties, specific heat treatment conditions for each type of BPs were employed. After initial treatments only HiPco BP and acetone-cleaned AD BP (suspended/rinsed with acetone) were selected for further

  12. Design of modified annulus air sampling system for the detection of leakage in waste transfer line

    International Nuclear Information System (INIS)

    Deokar, U.V; Khot, A.R.; Mathew, P.; Ganesh, G.; Tripathi, R.M.; Srivastava, Srishti

    2018-01-01

    Various liquid waste streams are generated during the operation of reprocessing plant. The High Level (HL), Intermediate Level (IL) and Low Level (LL) liquid wastes generated, are transferred from reprocessing plant to Waste Management Facility. These respective waste streams are transferred through pipe-in-pipe lines along the shielded concrete trench. For detection of radioactive leakage from primary waste transfer line into secondary line, sampling of the annulus air between the two pipes is carried out. The currently installed pressurized annulus air sampling system did not have online leakage detection provision. Hence, there are chances of personal exposure and airborne activity in the working area. To overcome these design flaws, free air flow modified online annulus air sampling system with more safety features is designed

  13. High-resolution real-time optical studies of radiological air sample filtration processes in an environmental continuous air monitor

    Science.gov (United States)

    Rodgers, John C.; Wasiolek, Piotr T.; Schery, Stephen D.; Alcantara, Raul E.

    1999-01-01

    The need for a continuous air monitor capable of quick and accurate measurements of airborne radioactivity in close proximity to the work environment during waste management, site restoration, and D&D operations led to the Los Alamos National Laboratory development of an environmental continuous air monitor (ECAM). Monitoring the hostile work environment of waste recovery, for example, presents unique challenges for detector design for detectors previously used for the clean room conditions of the typical plutonium laboratory. The environmental and atmospheric conditions (dust, high wind, etc.) influence aerosol particle penetration into the ECAM sampling head as well as the build-up of deposits on the ECAM filter.

  14. The use of cryogenic air sampling in the spectroscopy of airborne gamma-ray emitters

    International Nuclear Information System (INIS)

    Perdue, P.T.; Haywood, F.F.

    1982-01-01

    Wet air can be sampled over a period of four to twelve hours and, with a transfer into a special Marinelli-dewar, can be counted in a spectrometer for several hours. The present minimum detectable amount is about 4 Bq/m 3 for 222 Rn and 220 Rn with liquid air in the counting dewar equivalent to one cubic meter of ambient air. The amount of ambient air sampled can be determined from ambient pressure, temperature, and absolute humidity determinations. Standard meteorological tables are used to determine the weight of ambient air in grams/litre. This quantity divided into the net weight of liquid yields the total litres of ambient air sampled. Tests run so far with 85 Kr indicate that the noble fission gases behave in a manner similar to radon, allowing measurements of stack gases, reactor plumes, etc. The minimum detectable quantity of 85 Kr appears to be about 300 Bq/m 3 , depending upon the 222 Rn and 220 Rn content of the air

  15. Environmental monitoring of selected pesticides and organic chemicals in urban stormwater recycling systems using passive sampling techniques.

    Science.gov (United States)

    Page, Declan; Miotliński, Konrad; Gonzalez, Dennis; Barry, Karen; Dillon, Peter; Gallen, Christie

    2014-03-01

    Water recycling via aquifers has become a valuable tool to augment urban water supplies in many countries. This study reports the first use of passive samplers for monitoring of organic micropollutants in Managed Aquifer Recharge (MAR). Five different configurations of passive samplers were deployed in a stormwater treatment wetland, groundwater monitoring wells and a recovery tank to capture a range of polar and non-polar micropollutants present in the system. The passive samplers were analysed for a suite of pesticides, polycyclic aromatic hydrocarbons (PAHs) and other chemicals. As a result, 17 pesticides and pesticide degradation products, 5 PAHs and 8 other organic chemicals including flame retardants and fragrances were detected in urban stormwater recharging Aquifer Storage and Recovery (ASR) and an Aquifer Storage Transfer and Recovery (ASTR) system. Of the pesticides detected, diuron, metolachlor and chlorpyrifos were generally detected at the highest concentrations in one or more passive samplers, whereas chlorpyrifos, diuron, metolachlor, simazine, galaxolide and triallate were detected in multiple samplers. Fluorene was the PAH detected at the highest concentration and the flame retardant Tris(1-chloro-2-propyl)phosphate was the chemical detected in the greatest abundance at all sites. The passive samplers showed different efficiencies for capture of micropollutants with the Empore disc samplers giving the most reliable results. The results indicate generally low levels of organic micropollutants in the stormwater, as the contaminants detected were present at very low ng/L levels, generally two to four orders of magnitude below the drinking water guidelines (NHMRC, 2011). The efficiency of attenuation of these organic micropollutants during MAR was difficult to determine due to variations in the source water concentrations. Comparisons were made between different samplers, to give a field-based calibration where existing lab-based calibrations were

  16. Active (air-cooled) vs. passive (phase change material) thermal management of high power lithium-ion packs: Limitation of temperature rise and uniformity of temperature distribution

    Energy Technology Data Exchange (ETDEWEB)

    Sabbah, Rami; Kizilel, R.; Selman, J.R.; Al-Hallaj, S. [Center for Electrochemical Science and Engineering, Department of Chemical and Biological Engineering, Illinois Institute of Technology, 10 W. 33rd Street, Chicago, IL 60616 (United States)

    2008-08-01

    The effectiveness of passive cooling by phase change materials (PCM) is compared with that of active (forced air) cooling. Numerical simulations were performed at different discharge rates, operating temperatures and ambient temperatures of a compact Li-ion battery pack suitable for plug-in hybrid electric vehicle (PHEV) propulsion. The results were also compared with experimental results. The PCM cooling mode uses a micro-composite graphite-PCM matrix surrounding the array of cells, while the active cooling mode uses air blown through the gaps between the cells in the same array. The results show that at stressful conditions, i.e. at high discharge rates and at high operating or ambient temperatures (for example 40-45 C), air-cooling is not a proper thermal management system to keep the temperature of the cell in the desirable operating range without expending significant fan power. On the other hand, the passive cooling system is able to meet the operating range requirements under these same stressful conditions without the need for additional fan power. (author)

  17. Active (air-cooled) vs. passive (phase change material) thermal management of high power lithium-ion packs: Limitation of temperature rise and uniformity of temperature distribution

    Science.gov (United States)

    Sabbah, Rami; Kizilel, R.; Selman, J. R.; Al-Hallaj, S.

    The effectiveness of passive cooling by phase change materials (PCM) is compared with that of active (forced air) cooling. Numerical simulations were performed at different discharge rates, operating temperatures and ambient temperatures of a compact Li-ion battery pack suitable for plug-in hybrid electric vehicle (PHEV) propulsion. The results were also compared with experimental results. The PCM cooling mode uses a micro-composite graphite-PCM matrix surrounding the array of cells, while the active cooling mode uses air blown through the gaps between the cells in the same array. The results show that at stressful conditions, i.e. at high discharge rates and at high operating or ambient temperatures (for example 40-45 °C), air-cooling is not a proper thermal management system to keep the temperature of the cell in the desirable operating range without expending significant fan power. On the other hand, the passive cooling system is able to meet the operating range requirements under these same stressful conditions without the need for additional fan power.

  18. Dose estimation by simultaneous measurement of the radon/thoron concentration and the equilibrium factors in air using a passive dosemeter

    International Nuclear Information System (INIS)

    Urban, M.

    1984-03-01

    Responsible for an increased radiation exposure is the inhalation of radon and its short lived daughters. A time integrating passive dosemeter was developed to determine the concentrations of the radon isotopes as well as their equilibrium factors. The α energy spectrum inside a dosemeter is measured by means of a nuclear track detector. The concentrations in air and the equilibrium factors are calculated by using a new mathematical dosemeter model. A small pilot study in houses was done to test the dosemeter. (orig.) [de

  19. Passive Sampling and Analysis of Naphthalene in Internal Combustion Engine Exhaust with Retracted SPME Device and GC-MS

    Directory of Open Access Journals (Sweden)

    Nassiba Baimatova

    2017-07-01

    Full Text Available Exhaust gases from internal combustion engines are the main source of urban air pollution. Quantification of Polycyclic aromatic hydrocarbons (PAHs in the exhaust gases is needed for emissions monitoring, enforcement, development, and testing of control technologies. The objective was to develop quantification of gaseous naphthalene in diesel engine exhaust based on diffusion-controlled extraction onto a retracted solid-phase microextraction (SPME fiber coating and analysis on gas chromatography-mass spectrometry (GC-MS. Extraction of naphthalene with retracted fibers followed Fick’s law of diffusion. Extracted mass of naphthalene was proportional to Cg, t, Dg, T and inversely proportional to Z. Method detection limit (p = 0.95 was 11.5 ppb (0.06 mg·m−3 at t = 9 h, Z = 10 mm and T = 40 °C, respectively. It was found that the % mass extracted of naphthalene by SPME needle assembly depended on the type of fiber. Storage time at different temperatures did not affect analyte losses extracted by polydimethylsiloxane (PDMS 100 µm fiber. The developed method was tested on exhaust gases from idling pickup truck and tractor, and compared side-by-side with a direct injection of sampled exhaust gas method. Time-weighted average (TWA concentrations of naphthalene in exhaust gases from idling pickup truck and a tractor ranged from 0.08 to 0.3 mg·m−3 (15.3–53.7 ppb.

  20. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    Science.gov (United States)

    Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-01

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  1. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, Matthias, E-mail: matthias.schindler@physik.uni-erlangen.de; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-15

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO{sub 2} and reduced to graphite to determine {sup 14}C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  2. Monte Carlo simulation of air sampling methods for the measurement of radon decay products.

    Science.gov (United States)

    Sima, Octavian; Luca, Aurelian; Sahagia, Maria

    2017-08-01

    A stochastic model of the processes involved in the measurement of the activity of the 222 Rn decay products was developed. The distributions of the relevant factors, including air sampling and radionuclide collection, are propagated using Monte Carlo simulation to the final distribution of the measurement results. The uncertainties of the 222 Rn decay products concentrations in the air are realistically evaluated. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Actinide nuclides in environmental air and precipitation samples after the Chernobyl accident

    International Nuclear Information System (INIS)

    Rosner, G.; Hoetzl, H.; Winkler, R.

    1988-01-01

    The present paper describes the analysis of isotopes of uranium, neptunium, plutonium, americium and curium, in air and deposition samples taken at our laboratory site 10 km north of Munich, subsequent to the Chernobyl accident. Uranium-234, 237 U, 238 U, 239 Np, 238 Pu, 239+240 Pu and 242 Cm have been identified and upper limits of detection have been established for 241 Am and 244 Cm. Deposition and air concentration values are discussed. 12 refs., 1 fig., 2 tabs

  4. Passive alcohol sensors tested in 3 states for youth alcohol enforcement

    Science.gov (United States)

    1996-05-01

    Passive alcohol sensors were tested in three states to determine their effectiveness in enforcing zero tolerance or low BAC laws for under 21 age drivers. The passive alcohol sensor was designed to sample the air immediately around the suspect for si...

  5. A study on elemental composition in epiphytic lichen samples used as bioindicator of air pollution in Sao Paulo city

    International Nuclear Information System (INIS)

    Montezani, Edmila

    2010-01-01

    Studies on air pollution have intensified in recent years, due to the diversity of emissions and the effect caused to the health of populations. Consequently, several techniques have been investigated for air pollution evaluation and among them one that has gained considerable attention is that of biomonitoring. In this study chemical elemental levels in the atmosphere of Sao Paulo city were evaluated, by means of passive biomonitoring, using epiphytic Canoparmelia texana species, in order to compare between the results obtained in samples from different sites of Sao Paulo city and in a reference site of Ubatuba city, SP. Neutron activation analysis (NAA) procedure applied in the analyses consisted of irradiating aliquots of samples along with synthetic standards of elements in the nuclear reactor IEA-R1 for 16 hours under a thermal neutron flux of about 5.0 x 10 12 n cm -2 s -1 , followed by gamma ray spectrometry for the determination of As, Br, Ca, Co, Cr, Cs, Fe, K, La, Rb, Sc, Se and Zn. Results obtained in the analyses of lichens samples in replicates presented good reproducibility indicating homogeneity of the prepared samples. The precision and accuracy of the results were evaluated by the analyses of certified reference materials IAEA-336 Lichen and INCT-TL-1 Tea Leaves. Results obtained in the reference materials presented, in general, good precision, with relative standard deviations between 0.4 and 14.8% and good accuracy with relative errors between 0.2 and 8.7%. In Sao Paulo city, the lichens were collected in the following sites: Parque Dom Pedro II, Congonhas, Cidade Universitaria, Lapa, Mooca, Morumbi, Nossa Senhora do O, Parque Ibirapuera, Pinheiros, Santana, Santo Amaro and Taboao da Serra. Element concentrations found in lichens indicated a great variability depending on the sites where the samples were collected. The results obtained in the lichens submitted to the cluster analysis indicated three groups of sampling sites according to the

  6. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    Energy Technology Data Exchange (ETDEWEB)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J., E-mail: rc.nardes@gmail.com, E-mail: ramonziosp@yahoo.com.br, E-mail: francissanches@gmail.com, E-mail: hamiltongamafilho@hotmail.com, E-mail: davi.oliveira@uerj.br, E-mail: marcelin@uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Instituto de Fisica. Departamento de Fisica Aplicada e Termodinamica

    2015-07-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  7. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    International Nuclear Information System (INIS)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J.

    2015-01-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  8. Remote tritium-in-air sampling in reactor building at NAPS

    International Nuclear Information System (INIS)

    Mitra, S.R.; Lal Chand

    2000-01-01

    Tritium-in-air activity is an important parameter in PHW reactors from the point of view of internal exposure and heavy water escape from the system. The sampling technique in vogue in PHWRs, for measurement of tritium-in-air activity, requires collection of on the spot sample from different areas using a portable sampler. This sampler uses the bubbler method of sampling. As the areas of sampling are numerous, this technique is time consuming, laborious and can lead to significant internal exposure in areas where tritium-in-air activity is high. This technique is also error prone due to the heavy workload involved. A new scheme, in which the sampling of all the areas of reactor building is done through a sampling station, has been introduced for the first time in NAPS. This sampling station facilitates collection of samples from all the areas of reactor building, remotely and simultaneously at one place thereby reducing time, labour, exposure and error. This paper gives the details of the sampling system installed at NAPS. (author)

  9. Numerical Study on the Design Concept of an Air-Cooled Condensation Heat Exchanger in a Long-term Passive Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myoung Jun; Moon, Joo Hyung; Bae, Youngmin; Kim, Young In; Park, Hyun Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Hee Joon [Kookmin University, Seoul (Korea, Republic of)

    2016-10-15

    SMART is the only licensed SMR in the world since the Nuclear Safety and Security Commission (NSSC) issued officially the Standard Design Approval (SDA) on 4 July 2012. Recently, the pre-project engineering (PPE) was officially launched for the construction of SMART and developing human resources capability. Both KAERI and King Abdullah City for Atomic and Renewable Energy (K.A. CARE) will conduct a three-year preliminary study to review the feasibility of building SMART and to prepare for its commercialization. SMART is equipped with passive cooling systems in order to enhance the safety of the reactor. The PRHRS (Passive Residual Heat Removal System) is the major passive safety system, which is actuated after an accident to remove the residual heat and the sensible heat from the RCS (Reactor Coolant System) through the steam generators (SGs) until the safe shutdown condition is reached. In this study, condensing heat transfer correlations in TSCON were validated using experimental data. It was shown that most of the condensation correlation gave satisfactory predictions of the cooling capacity of an-air cooled condensation heat exchanger.

  10. Air-Stable Surface-Passivated Perovskite Quantum Dots for Ultra-Robust, Single- and Two-Photon-Induced Amplified Spontaneous Emission

    KAUST Repository

    Pan, Jun

    2015-12-01

    We demonstrate ultra-air- and photostable CsPbBr3 quantum dots (QDs) by using an inorganic–organic hybrid ion pair as the capping ligand. This passivation approach to perovskite QDs yields high photoluminescence quantum yield with unprecedented operational stability in ambient conditions (60 ± 5% lab humidity) and high pump fluences, thus overcoming one of the greatest challenges impeding the development of perovskite-based applications. Due to the robustness of passivated perovskite QDs, we were able to induce ultrastable amplified spontaneous emission (ASE) in solution processed QD films not only through one photon but also through two-photon absorption processes. The latter has not been observed before in the family of perovskite materials. More importantly, passivated perovskite QD films showed remarkable photostability under continuous pulsed laser excitation in ambient conditions for at least 34 h (corresponds to 1.2 × 108 laser shots), substantially exceeding the stability of other colloidal QD systems in which ASE has been observed.

  11. Numerical Study on the Design Concept of an Air-Cooled Condensation Heat Exchanger in a Long-term Passive Cooling System

    International Nuclear Information System (INIS)

    Kim, Myoung Jun; Moon, Joo Hyung; Bae, Youngmin; Kim, Young In; Park, Hyun Sik; Lee, Hee Joon

    2016-01-01

    SMART is the only licensed SMR in the world since the Nuclear Safety and Security Commission (NSSC) issued officially the Standard Design Approval (SDA) on 4 July 2012. Recently, the pre-project engineering (PPE) was officially launched for the construction of SMART and developing human resources capability. Both KAERI and King Abdullah City for Atomic and Renewable Energy (K.A. CARE) will conduct a three-year preliminary study to review the feasibility of building SMART and to prepare for its commercialization. SMART is equipped with passive cooling systems in order to enhance the safety of the reactor. The PRHRS (Passive Residual Heat Removal System) is the major passive safety system, which is actuated after an accident to remove the residual heat and the sensible heat from the RCS (Reactor Coolant System) through the steam generators (SGs) until the safe shutdown condition is reached. In this study, condensing heat transfer correlations in TSCON were validated using experimental data. It was shown that most of the condensation correlation gave satisfactory predictions of the cooling capacity of an-air cooled condensation heat exchanger

  12. Technical basis and evaluation criteria for an air sampling/monitoring program

    International Nuclear Information System (INIS)

    Gregory, D.C.; Bryan, W.L.; Falter, K.G.

    1993-01-01

    Air sampling and monitoring programs at DOE facilities need to be reviewed in light of revised requirements and guidance found in, for example, DOE Order 5480.6 (RadCon Manual). Accordingly, the Oak Ridge National Laboratory (ORNL) air monitoring program is being revised and placed on a sound technical basis. A draft technical basis document has been written to establish placement criteria for instruments and to guide the ''retrospective sampling or real-time monitoring'' decision. Facility evaluations are being used to document air sampling/monitoring needs, and instruments are being evaluated in light of these needs. The steps used to develop this program and the technical basis for instrument placement are described

  13. Recommended radiological air sampling and internal contamination control at nuclear power plants

    International Nuclear Information System (INIS)

    Rich, B.L.; Ritter, P.D.; Martz, D.E.

    1984-01-01

    It has long been recognized by the NRC Technical Staffs that estimating the quantity of radioactivity inhaled by an individual worker involved large uncertainties. General air samples usually produce concentrations lower than those in the workers Breathing Zone (BZ). NRC guides have recognized this problem by specifying air monitoring programs which sample the Breathing Zone or concentrations known to be higher than that actually inhaled. In addition the availability of suitable samplers to obtain BZ samples and the practicality of requiring their use was somewhat in question to the NRC technical staff. AN NRC development contract was issued to provide a detailed review of the technical aspects of the problems and recommendations for practical upgrade of federal guidance. This project accomplished a review of the nuclear industry experience and knowledge through a literature search, site visits to representative licensed facilities, telephone surveys of many others, laboratory testing of personal air samplers (lapel samplers) and aerosol diffusion experiments to verify key conclusions and assumptions

  14. Sampling for Air Chemical Emissions from the Life Sciences Laboratory II

    Energy Technology Data Exchange (ETDEWEB)

    Ballinger, Marcel Y. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lindberg, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-03-30

    Sampling for air chemical emissions from the Life Science Laboratory II (LSL-II) ventilation stack was performed in an effort to determine potential exposure of maintenance staff to laboratory exhaust on the building roof. The concern about worker exposure was raised in December 2015 and several activities were performed to assist in estimating exposure concentrations. Data quality objectives were developed to determine the need for and scope and parameters of a sampling campaign to measure chemical emissions from research and development activities to the outside air. The activities provided data on temporal variation of air chemical concentrations and a basis for evaluating calculated emissions. Sampling for air chemical emissions was performed in the LSL-II ventilation stack over the 6-week period from July 26 to September 1, 2016. A total of 12 sampling events were carried out using 16 sample media. Resulting analysis provided concentration data on 49 analytes. All results were below occupational exposure limits and most results were below detection limits. When compared to calculated emissions, only 5 of the 49 chemicals had measured concentrations greater than predicted. This sampling effort will inform other study components to develop a more complete picture of a worker’s potential exposure from LSL-II rooftop activities. Mixing studies were conducted to inform spatial variation in concentrations at other rooftop locations and can be used in conjunction with these results to provide temporal variations in concentrations for estimating the potential exposure to workers working in and around the LSL-II stack.

  15. Known volume air sampling pump. Final summary report Jun 1975--Nov 1976

    International Nuclear Information System (INIS)

    McCullough, J.E.; Peterson, A.

    1976-11-01

    The purpose of this development program was to design and develop a known volume air sampling pump for use in measuring the amount of radioactive material in the atmosphere of an underground uranium mine. The principal nuclear radiation hazard to underground uranium mines comes from the mine atmosphere. Daughter products of radon-222 are inhaled by the miner resulting in a relatively high lung cancer rate among these workers. Current exposure control practice employs spot sampling in working areas to measure working level values. Currently available personal air sampling pumps fail to deliver known volumes of air under widely changing differential pressures. A unique type of gas pump known as the scroll compressor, developed by Arthur D. Little, Inc., that has no values and few moving parts is expected to provide a practical, efficient, and dependable air pump for use in dosimeters. The three deliverable known volume air sampling pumps resulting from this work incorporate a scroll pump, drive motor, speed control electronics, and battery pack in a container suitable for attachment to a miner's belt

  16. Analysis of tree bark samples for air pollution biomonitoring of an urban area

    International Nuclear Information System (INIS)

    Martins, Ana Paula G.; Negri, Elnara M.; Saldiva, Paulo H.N.

    2009-01-01

    Air pollution is receiving much attention as a public health problem around the world due to its adverse health effects from exposures by urban populations. Within this context, the use of vegetal biomonitoring to evaluate air quality has been investigated throughout the world. Air pollutant levels are high in the city of Sao Paulo, SP, Brazil and being the vehicle emissions its main source. The aim of this study was to evaluate concentrations of As, Ba, Br, Ca, Co, Cr, Cu, Fe, Mn, Pb, S, Sb and Zn in tree bark samples used as biomonitor of urban air pollution. Concentrations of these elements were determined in barks collected in trees of the Ibirapuera Park, one of the biggest and most visited parks of the city of Sao Paulo city. Samples of tree barks were also collected in a site outside the city of Sao Paulo, in a rural area of Embu-Guacu, considered as a control site. The element concentrations were determined by the methods of Instrumental Neutron Activation Analysis (INAA) and of Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF). The findings of this study showed that tree bark samples may be used as biomonitors of urban air pollution in a micro scale, and both techniques, INAA and EDXRF, can be used to evaluate element concentrations in tree bark samples. (author)

  17. Profiling quinones in ambient air samples collected from the Athabasca region (Canada).

    Science.gov (United States)

    Wnorowski, Andrzej; Charland, Jean-Pierre

    2017-12-01

    This paper presents new findings on polycyclic aromatic hydrocarbon oxidation products-quinones that were collected in ambient air samples in the proximity of oil sands exploration. Quinones were characterized for their diurnal concentration variability, phase partitioning, and molecular size distribution. Gas-phase (GP) and particle-phase (PM) ambient air samples were collected separately in the summer; a lower quinone content was observed in the PM samples from continuous 24-h sampling than from combined 12-h sampling (day and night). The daytime/nocturnal samples demonstrated that nighttime conditions led to lower concentrations and some quinones not being detected. The highest quinone levels were associated with wind directions originating from oil sands exploration sites. The statistical correlation with primary pollutants directly emitted from oil sands industrial activities indicated that the bulk of the detected quinones did not originate directly from primary emission sources and that quinone formation paralleled a reduction in primary source NO x levels. This suggests a secondary chemical transformation of primary pollutants as the origin of the determined quinones. Measurements of 19 quinones included five that have not previously been reported in ambient air or in Standard Reference Material 1649a/1649b and seven that have not been previously measured in ambient air in the underivatized form. This is the first paper to report on quinone characterization in secondary organic aerosols originating from oil sands activities, to distinguish chrysenequinone and anthraquinone positional isomers in ambient air, and to report the requirement of daylight conditions for benzo[a]pyrenequinone and naphthacenequinone to be present in ambient air. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  18. A simple passive method of collecting water vapour for environmental tritium monitoring

    International Nuclear Information System (INIS)

    Iida, T.; Fukuda, H.; Ikebe, Y.; Yokoyama, S.

    1995-01-01

    To investigate the average behaviour of tritium in an atmospheric environment, it is necessary to collect water vapour in air over a long period at numerous locations. For the purpose of the study, the passive method was developed: this is handy, low-priced and could collect water vapour in air without motive power. This paper describes the characteristics of the passive collecting method, the performance of water collection in outdoor air and the measurements of tritium concentrations in water samples collected by the passive method. (author)

  19. An advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1984-01-01

    An improved computer-controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high-speed matrix printer and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  20. Advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1983-01-01

    An improved computer controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high speed matrix printer, and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction, and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha, and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  1. Field evaluation of a tailor-made new passive sampler for the determination of NO2 levels in ambient air.

    Science.gov (United States)

    Ozden, Ozlem; Dogeroglu, Tuncay

    2008-07-01

    This study describes the field evaluation of a tailor-made new glass passive sampler developed for the determination of NO(2), based on the collection on triethanolemine (TEA)-coated fibre filter paper. The sampler has been derived from a Palmes design. The overall uncertainty of the sampler was determined by using Griess-Saltzman ASTM D 1607 standard test method as a reference method. The agreement between the results of the passive sampler and the reference method was +/-7.90% with the correlation coefficient of 0.90. Method precision in terms of coefficient of variance (CV) for three simultaneously applied passive samplers was 8.80%. The uptake rate of NO(2) was found to be 2.49 ml/min in a very good agreement with the value calculated from theory (2.63 ml/min). Sampler detection limit was 1.99 microg/m(3) for an exposure period of 1 week and the sampler can be stored safely for a period of up to 6 weeks before exposure. A comparison of the sampler performance was conducted against a commercially available diffusion tube (Gradko diffusion tube). The results from the applied statistical paired t test indicated that there was no significant difference between the performances of two passive samplers (R (2) > 0.90). Also, another statistical comparison was carried out between the dark and transparent glass passive samplers. The results from the dark-colour sampler were higher than that from the transparent sampler (approximately 25%) during the summer season because of the possible photodegradation of NO(2)-TEA complex.

  2. Passive safety; Passive Sicherheit

    Energy Technology Data Exchange (ETDEWEB)

    Rueckert, J. [Skoda Auto a.s., Mlada Boleslav (Czech Republic). Interieurentwicklung und Versuche; Hau, M. [Skoda Auto a.s., Mlada Boleslav (Czech Republic). Koordination der Fahrzeugsicherung

    2004-05-01

    The specifications for passive safety are partly based on the legal requirements for all export markets combined with the strict internal standards of Volkswagen Group. The Euro NCAP tests and their precisely defined testing methods using the new point assessment are very important. (orig.)

  3. Ambient air sampling of organic pollutants and heavy metals within the EU/93/AIR/22 PHARE Project

    International Nuclear Information System (INIS)

    Kocan, A.

    1997-01-01

    Within the framework of the project the concentrations of eight heavy metals, vapour mercury, seven polychlorinated dibenzo-p-dioxin's, ten polychlordibenzofuran congeners, eighteen polychlorinated biphenyls, two chlorinated pesticides (hexachlorobenzene, p,p'-DDE and p,p'-DDT), fourteen polycyclic aromatic hydrocarbons, forty-two volatile organic compounds, total suspended particles were analysed. The morphology characterization of collected airborne particles and bioassays aimed at the evaluation of the mutagenic potency of pollutants present in collected air were also performed. Ambient air heavy metals were caught on cellulose filters using the same type of the sampler used for semi-volatile compounds sampling and analysed by atomic spectrometry. Vapour mercury was trapped on gold sand packed in a tube through which about 280 L of ambient air during 24 hours were drawn. On-site analysis was performed by an atomic fluorescence analyzer. Inhalable air particles, i.e particles less than 10 μm in diameter were collected by a sampler equipped with a cascade impactor fractionating into five size fractions involving respirable (<3 μm) fractions. The morphology and composition of the respirable fractions was investigated by scanning electron microscopy and X-ray microanalysis

  4. Ambient air sampling for radioactive air contaminants at Los Alamos National Laboratory: A large research and development facility

    International Nuclear Information System (INIS)

    Eberhart, C.F.

    1998-01-01

    This paper describes the ambient air sampling program for collection, analysis, and reporting of radioactive air contaminants in and around Los Alamos National Laboratory (LANL). Particulate matter and water vapor are sampled continuously at more than 50 sites. These samples are collected every two weeks and then analyzed for tritium, and gross alpha, gross beta, and gamma ray radiation. The alpha, beta, and gamma measurements are used to detect unexpected radionuclide releases. Quarterly composites are analyzed for isotopes of uranium ( 234 U, 235 U, 238 U), plutonium ( 238 Pu, 239/249 Pu), and americium ( 241 Am). All of the data is stored in a relational database with hard copies as the official records. Data used to determine environmental concentrations are validated and verified before being used in any calculations. This evaluation demonstrates that the sampling and analysis process can detect tritium, uranium, plutonium, and americium at levels much less than one percent of the public dose limit of 10 millirems. The isotopic results also indicate that, except for tritium, off-site concentrations of radionuclides potentially released from LANL are similar to typical background measurements

  5. Air-sampling inlet contamination by aircraft emissions on the NASA CV-990 aircraft

    Science.gov (United States)

    Condon, E. P.; Vedder, J. F.

    1984-01-01

    Results of an experimental investigation of the contamination of air sampling inlets by aircraft emissions from the NASA CV-990 research aircraft are presented. This four-engine jet aircraft is a NASA facility used for many different atmospheric and meteorological experiments, as well as for developing spacecraft instrumentation for remote measurements. Our investigations were performed to provide information on which to base the selection of sampling locations for a series of multi-instrument missions for measuring tropospheric trace gases. The major source of contamination is the exhaust from the jet engines, which generate many of the same gases that are of interest in atmospheric chemistry, as well as other gases that may interfere with sampling measurements. The engine exhaust contains these gases in mixing ratios many orders of magnitude greater than those that occur in the clean atmosphere which the missions seek to quantify. Pressurized samples of air were collected simultaneously from a scoop located forward of the engines to represent clean air and from other multiport scoops at various aft positions on the aircraft. The air samples were analyzed in the laboratory by gas chromatography for carbon monoxide, an abundant combustion by-product. Data are presented for various scoop locations under various flight conditions.

  6. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    International Nuclear Information System (INIS)

    MULKEY, C.H.

    1999-01-01

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues

  7. Solubility testing of actinides on breathing-zone and area air samples

    International Nuclear Information System (INIS)

    Metzger, R.L.; Jessop, B.H.; McDowell, B.L.

    1996-02-01

    A solubility testing method for several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALS reg-sign) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of U 3 O 8 . Profiles developed for U 3 O 8 samples show good agreement with in vitro and in vivo tests performed by other investigators on samples from the same uranium mills

  8. Dioxin emission factors for automobiles from tunnel air sampling in Northern Taiwan.

    Science.gov (United States)

    Chang, Moo Been; Chang, Shu Hao; Chen, Yuan Wu; Hsu, Hsuan Chien

    2004-06-05

    This study measured PCDD/F concentrations in tunnel air and vehicle exhaust. The ambient air samples were collected with air samplers (Tisch PS-1) complying with USEPA TO-9A. The results indicate that the tunnel air had a PCDD/F TEQ concentration about two times as high as that of outside air (47.3 and 57.1 fg-I-TEQ/m3 for tunnel air vs. 37.1 fg-I-TEQ/m3 and 23.3 fg-I-TEQ/m3 for outside air, respectively). This provides the direct evidence that PCDD/F compounds are emitted from the combustion processes in gasoline- and diesel-fueled engines. According to the tunnel study, the emission factors ranged from 5.83 to 59.2 pg I-TEQ/km for gasoline vehicles and 23.32 to 236.65 pg I-TEQ/km of diesel vehicles. This indicates that the dioxin emission factor in Taiwan is lower than that measured in USA, Norway and Germany. When the speed of the diesel vehicle was set at 40 km/h, the dioxin concentration emitted from diesel vehicle was 278 pg/m3 (6.27 pg-I-TEQ/m3) from tailpipe testing. However, when the diesel vehicle was idled, the dioxin concentration increased greatly to 4078 pg/m3 (41.9 pg-I-TEQ/m3). From the results of tunnel air sampling, the PCDD/Fs emission from automobiles in Taiwan was estimated as 3.69 g I-TEQ per year. Copryright 2003 Elsevier B.V.

  9. Studies on radioactivities of dust samples in the air at high altitudes

    International Nuclear Information System (INIS)

    Kohara, Eri; Muronoi, Naohiro

    2015-01-01

    The radioactivity concentrations of airborne dust samples were studied. The samples had been collected at high altitude by the Japan Air Self-Defense Force from April 2013 to March 2014. The obtained data were used for gross beta radioactivity analysis and gamma nuclide analysis. It is shown that cesium 137 was mainly detected at the 10 km and 3 km altitude of central area of Japan in several samples. Gaseous radioiodine was not detected in all the samples. Radioactive xenon was detected but the concentration did not show significant difference to the background level. (author)

  10. Simple and rapid measurement of α-rays on smear samples using air luminescence

    International Nuclear Information System (INIS)

    Takiue, M.

    1980-01-01

    The α-activity collected on smear samples has been measured indirectly using an air luminescence counting method and a liquid scintillation spectrometer. In this method, air luminescence, attributed to the fluorescence emitted by nitrogen molecules excited by α-rays in air, serves to detect α-rays. Thus, sample preparation and α-ray measurement are simple and rapid, and moreover, no radioactive waste solution is produced. Taking into account a low background and a counting efficiency between 10 and 20%, it is estimated that the detectable limit for α-ray measurement is about 1 x 10 -7 μCi/cm 2 for loose contamination. This method is convenient to use in the routine analysis of α-ray-emitting nuclides on smear paper. (author)

  11. Air sampling in the workplace to meet the new part 20 requirements

    International Nuclear Information System (INIS)

    McGuire, S.; Hickey, E.E.; Knox, W.

    1991-01-01

    The US Nuclear Regulatory Commission is developing a Regulatory Guide on air sampling in the workplace to meet the requirements of the revised Part 20. The guide will be accompanied by a technical manual describing and giving examples of how to meet the recommendations in the guide. Draft versions of the guide and manual are scheduled to be published for public comment this year. A final guide and manual, revised to consider the public comments, are scheduled to be published in 1992. This talk will summarize some of the more important features of the guide and manual. In particular, the talk will discuss how to demonstrate that samples taken to estimate worker intakes are representative of the air inhaled by workers and what measurements are necessary if a licensee wants to adjust derived air concentrations to account for particle size

  12. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    Energy Technology Data Exchange (ETDEWEB)

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear

  13. Active and passive measurements of radon/thoron exhalation from coal and flyash samples collected from various thermal power plants of Delhi, India

    International Nuclear Information System (INIS)

    Singh, Lalit Mohan; Kumar, Rajesh; Sahoo, B.K.; Sapra, B.K.; Rajendra Prasad

    2013-01-01

    Measurement of radon ( 222 Rn) exhalation from coal, flyash and soil samples was carried out using active (Scintillation based Smart Radon Monitor) as well as passive technique (SSNTD based Can technique). In addition, thoron ( 220 Rn) exhalation measurements were also made for the above samples using Scintillation based Smart Thoron Monitor. To the best of our knowledge, thoron exhalation measurement is first of its kind in India. In this study, a total of 26 samples collected from Badarpur Thermal Power Station, Badarpur and Rajghat Power Station, Rajghat, Delhi were analysed. Thoron surface exhalation rate measured by Scintillation based Thoron Monitor for Badarpur Thermal Power Station varied from 327.8 Bq/m 2 /h to 874.2 Bq/m 2 /h and for Rajghat Thermal Power Station it varied from 176.0 Bq/m 2 /h to 781.1 Bq/m 2 /h. Similarly, the radon mass exhalation rate measured by active technique varied from 12.13 mBq/Kg/h to 118.08 mBq/Kg/h for the samples collected from Badarpur Thermal Power Station; while it varied from 15.00 Bq/Kg/h to 168.07 mBq/Kg/h for the samples collected from Rajghat Thermal Power station. On the other hand, result of measurements made by the conventional Can technique were significantly lower varying from 0.44 mBq/Kg/h to 2.34 mBq/Kg/h for Rajghat Thermal Power Station and from 0.78 mBq/Kg/h to 2.88 mBq/Kg/h for Badarpur Thermal Power Station. This vast variation in the results obtained by active and passive techniques is due to the fact that the active technique accounts for the effect of back-diffusion and possible leakage from the chamber in the process of least square fitting of exponential model while it is not so in the case of SSNTD based Can technique. In view of this, results of active technique are more reliable as compared to the passive technique. More importantly, there was no thoron interference in the radon measurement by the active technique. Further experiments are being carried out using controlled radon and thoron

  14. Technical assessment of compliance with workplace air sampling requirements in the 300 Area

    International Nuclear Information System (INIS)

    Olsen, P.A.

    1995-01-01

    The purpose of this Technical Work Document is to satisfy HSRCM-1, the ''Hanford Site Radiological Control Manual.'' Article 551.4 of that manual states a requirement for a documented study of facility workplace air sampling programs (WPAS). This first revision of the original Supporting Document covers the period from January 1, 1995 to December 31, 1995. HSRCM-1 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE/EH-0256T ''US Department of Energy Radiological Control Manual'' as it applies to programs at Hanford. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. There are also several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of 300 Areas' workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance. The areas evaluated were the 340 Facility, the Advanced Reactor Operations Division Facilities, the N Reactor Fuels Supply Facility, and The Geotechnical Engineering Laboratory

  15. Air and smear sample calculational tool for Fluor Hanford Radiological control

    International Nuclear Information System (INIS)

    BAUMANN, B.L.

    2003-01-01

    A spreadsheet calculation tool was developed to automate the calculations performed for determining the concentration of airborne radioactivity and smear counting as outlined in HNF--13536, Section 5.2.7, ''Analyzing Air and Smear Samples''. This document reports on the design and testing of the calculation tool. Radiological Control Technicians (RCTs) will save time and reduce hand written and calculation errors by using an electronic form for documenting and calculating work place air samples. Current expectations are RCTs will perform an air sample and collect the filter or perform a smear for surface contamination. RCTs will then survey the filter for gross alpha and beta/gamma radioactivity and with the gross counts utilize either hand calculation method or a calculator to determine activity on the filter. The electronic form will allow the RCT with a few key strokes to document the individual's name, payroll, gross counts, instrument identifiers; produce an error free record. This productivity gain is realized by the enhanced ability to perform mathematical calculations electronically (reducing errors) and at the same time, documenting the air sample

  16. Probe sampling measurements and modeling of nitric oxide formation in ethane + air flames

    NARCIS (Netherlands)

    Dyakov, I.V.; Ruyck, de J.; Konnov, A.A.

    2007-01-01

    Burning velocity and probe sampling measurements of the concentrations of O2, CO2, CO and NO in the post-flame zone of ethane + air flames are reported. The heat flux method was used for stabilization of laminar, premixed, non-stretched flames on a perforated plate burner at 1 atm. Axial profiles of

  17. The sampling of sulfur dioxide in air with impregnated filter paper

    NARCIS (Netherlands)

    Huygen, C.

    1963-01-01

    A method is suggested for the sampling of sulfur dioxide in air with impregnated filter paper instead of bubblers. The best aqueous impregnating solution contained potassium hydroxide with glycerol or triethanolamine. The possibilities and limitations of the method are discussed. High collection

  18. Measurement of the carbon 14 activity at natural level in air samples

    International Nuclear Information System (INIS)

    Olivier, A.; Tenailleau, L.; Baron, Y.; Maro, D.

    2004-01-01

    The aim of the study was to measure the carbon 14 activity at natural level in air samples using classical methods of radiochemistry and beta counting. Three different methods have been tested in order to minimise the detection limit. In the three methods, the first step consists in trapping the atmospheric carbon 14 into NaOH (1N) using a bubbling chamber. The atmospheric carbon dioxide reacts with NaOH to form Na 2 CO 3 . In the first method the Na 2 CO 3 solution is mixed with a liquid scintillate and is directly analysed by liquid scintillation counting (LSC). The detection limit is approximately 1 Bq/m 3 of air samples. The second method consists in evaporating the carbonate solution and then counting the solid residue with a proportional gas circulation counter. The detection limit obtained is lower than the first method (0.4 Bq/m 3 of air samples). In the third method, Na 2 CO 3 is precipitated into CaCO 3 in presence of CaCl 2 . CaCO 3 is then analysed by LSC. This method appear to be the most appropriate, the detection limit is 0.05 Bq/m 3 of air samples. (author)

  19. Measure Guideline: Passive Vents

    Energy Technology Data Exchange (ETDEWEB)

    Berger, David [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Neri, Robin [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2016-02-05

    This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated source of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.

  20. Rapid sampling of BTEX in air by SPME in the city of Nice and at the Nice-Cote d'Azur airport

    International Nuclear Information System (INIS)

    Tumbiolo, S.; Gal, J.F.; Maria, P.Ch.; Laborde, P.; Teton, S.

    2006-01-01

    This article presents the results of a tentative application of Solid Phase Micro Extraction (SPME) to the analysis of BTEX (benzene, toluene, ethyl-benzene and xylenes) at the μg/m 3 level in indoor and outdoor air. The salient features of the method validation are reported. Sampling by QUALITAIR using Radiello passive samplers, was carried out from 2001 to 2004 in the city of Nice and its airport. Urban traffic impact was proved, but a link between BTX concentrations and the variations of airport activities was not clearly established. During the same period, several samplings were performed using SPME. Taking into account the short (30 minutes) sampling time, rapid changes of BTEX concentrations were evidenced, as for example the start of airplane engines. As field studies have shown, SPME technique appears as a method of choice for fast qualitative analysis and quantitative determination of Volatile Organic Compounds (VOC). The small dimensions of the SPME sampling system and the short sampling time let envisage its utilisation for the rapid diagnostic and the monitoring of indoor air quality. (author)

  1. Overview of the U.S. EPA/SERDP/ESTCP: Laboratory, Field, and Analytical Procedures for Using Passive Sampling in the Evaluation of Contaminated Sediments: User’s Manual.

    Science.gov (United States)

    Passive sampling is used for applications at contaminated sediment sites including performing assessments of contaminant bioavailability (i.e., freely dissolved concentration (Cfree)), conducting remedial investigations and feasibility studies, and assessing the potential for con...

  2. High-throughput liquid-absorption air-sampling apparatus and methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-11

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is < 10 cm of water, usually < 5 cm of water. The sampler's collection efficiency is usually > 20% for vapors or airborne particulates in the 2--3 microns range and > 50% for particles larger than 4 microns. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  3. High-throughput liquid-absorption air-sampling apparatus and methods

    Science.gov (United States)

    Zaromb, Solomon

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is 20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  4. High-throughput liquid-absorption air-sampling apparatus and methods

    International Nuclear Information System (INIS)

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is 20% for vapors or airborne particulates in the 2--3 microns range and > 50% for particles larger than 4 microns. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives

  5. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    MULKEY, C.H.

    1999-07-06

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

  6. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    International Nuclear Information System (INIS)

    MULKEY, C.H.

    1999-01-01

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants

  7. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis; FINAL

    International Nuclear Information System (INIS)

    MULKEY, C.H.

    1999-01-01

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants

  8. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    International Nuclear Information System (INIS)

    Barnett, J.M.

    2008-01-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity of particulate radioactive air samples. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor(reg s ign) 3000) used at PNNL for self absorption effects. There were two methods used in the study, (1) to compare the radioactivity concentration by direct gas-flow proportional counting of the filter to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection and (2) to evaluate sample filters by high resolution visual/infrared microscopy to determine the depth of material loading on or in the filter fiber material. Sixty samples were selected from the archive for acid digestion in the first method and about 30 samples were selected for high resolution visual/infrared microscopy. Mass loading effects were also considered. From the sample filter analysis, large error is associated with the average self absorption factor, however, when the data is compared directly one-to-one, statistically, there appears to be good correlation between the two analytical methods. The mass loading of filters evaluated was <0.2 mg cm-2 and was also compared against other published results. The microscopy analysis shows the sample material remains on the top of the filter paper and does not imbed into the filter media. Results of the microscopy evaluation lead to the conclusion that there is not a mechanism for significant self absorption. The overall conclusion is that self-absorption is not a significant factor in the analysis of filters used at PNNL for radioactive air stack sampling of radionuclide particulates and that an applied correction factor is conservative in determining overall sample activity. A new self absorption factor of 1.0 is recommended

  9. Quantitative analysis of untreated oil samples in in-air PIXE

    International Nuclear Information System (INIS)

    Sera, K.; Goto, S.; Takahashi, C.; Saitoh, Y.

    2010-01-01

    The method of quantitative analysis of oil samples in in-air PIXE has been developed on the basis of a standard-free method. The components of the continuous X-rays originated from air and backing film can be exactly subtracted using a blank spectrum after normalization by the yields of Ar K-α X-rays. The method was developed using nine oil samples including standard oils and its accuracy was confirmed by comparing the results with those obtained by the internal-standard method. Validity of the method for practical oil samples was confirmed for various kinds of oils such as engine, machine and cooking oils. It was found that the method is effective for various kinds of oils whatever elements we designate as an index element. (author)

  10. Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

    Science.gov (United States)

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

  11. Sampling technologies and air pollution control devices for gaseous and particulate arsenic: a review

    International Nuclear Information System (INIS)

    Helsen, Lieve

    2005-01-01

    Direct measurement of arsenic release requires a good sampling and analysis procedure in order to capture and detect the total amount of metals emitted. The literature is extensively reviewed in order to evaluate the efficiency of full field-scale and laboratory scale techniques for capturing particulate and gaseous emissions of arsenic from the thermo-chemical treatment of different sources of arsenic. Furthermore, trace arsenic concentrations in ambient air, national standard sampling methods and arsenic analysis methods are considered. Besides sampling techniques, the use of sorbents is also reviewed with respect to both approaches (1) to prevent the metals from exiting with the flue gas and (2) to react or combine with the metals in order to be collected in air pollution control systems. The most important conclusion is that submicron arsenic fumes are difficult to control in conventional air pollution control devices. Complete capture of the arsenic species requires a combination of particle control and vapour control devices. - Submicron arsenic fumes are difficult to control in conventional air pollution control devices

  12. Actinide nuclides in environmental air and precipitation samples after the Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Rosner, G.; Hoetzl, H.; Winkler, R. (Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen (West Germany))

    1988-01-01

    The present paper describes the analysis of isotopes of uranium, neptunium, plutonium, americium and curium, in air and deposition samples taken at our laboratory site 10 km north of Munich, subsequent to the Chernobyl accident. Uranium-234, {sup 237}U, {sup 238}U, {sup 239}Np, {sup 238}Pu, {sup 239+240}Pu and {sup 242}Cm have been identified and upper limits of detection have been established for {sup 241}Am and {sup 244}Cm. Deposition and air concentration values are discussed. 12 refs., 1 fig., 2 tabs.

  13. The application of x-ray fluorescence spectrometry for multielemental analysis of air particulate samples

    International Nuclear Information System (INIS)

    Mohamad Rashid Mohamad Yusoff

    1986-01-01

    The performance of XRF spectrometer as a tool for multielemental analysis of air pollution samples was discussed. The non-destructive couples with multielemental nature of the technique satisfactory sensitivity for most elements were the most important characteristics for its popularity as a method of analysis. Thus, the technique promises a significant reduction in cost and time of analysis. As a result, more extensive and revealing air particulates survey should be possible, with consequent improvements in the discovery and positive identification of particulate pollution sources. (author)

  14. Calibration of silicone rubber rods as passive samplers for pesticides at two different flow velocities: Modeling of sampling rates under water boundary layer and polymer control.

    Science.gov (United States)

    Martin, Alexis; Margoum, Christelle; Jolivet, Antoine; Assoumani, Azziz; El Moujahid, Bachir; Randon, Jérôme; Coquery, Marina

    2018-04-01

    There is a need to determine time-weighted average concentrations of polar contaminants such as pesticides by passive sampling in environmental waters. Calibration data for silicone rubber-based passive samplers are lacking for this class of compounds. The calibration data, sampling rate (R s ), and partition coefficient between silicone rubber and water (K sw ) were precisely determined for 23 pesticides and 13 candidate performance reference compounds (PRCs) in a laboratory calibration system over 14 d for 2 water flow velocities, 5 and 20 cm s -1 . The results showed that an in situ exposure duration of 7 d left a silicone rubber rod passive sampler configuration in the linear or curvilinear uptake period for 19 of the pesticides studied. A change in the transport mechanism from polymer control to water boundary layer control was observed for pesticides with a log K sw of approximately 3.3. The PRC candidates were not fully relevant to correct the impact of water flow velocity on R s . We therefore propose an alternative method based on an overall resistance to mass transfer model to adjust R s from laboratory experiments to in situ hydrodynamic conditions. We estimated diffusion coefficients (D s ) and thickness of water boundary layer (δ w ) as adjustable model parameters. Log D s values ranged from -12.13 to -10.07 m 2  s -1 . The estimated δ w value showed a power function correlation with water flow velocity. Environ Toxicol Chem 2018;37:1208-1218. © 2017 SETAC. © 2017 SETAC.

  15. Diurnal and seasonal variation in air exchange rates and interzonal airflows measured by active and passive tracer gas in homes

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Gustavsen, Sine; Frederiksen, Marie

    2016-01-01

    Outdoor air delivery to buildings is an important parameter in the assessment of pollutant exposure indoors. Detailed and well controlled measurements of air exchange rates (AER) and interzonal airflows in residential environment are scarce. We measured the outdoor AERs in up to six rooms in five...... rooms. Window opening behavior had a strong influence on AERs, which were highest during occupied daytime periods, lowest in the night; highest in the summer, lowest in the winter. Significant differences were found between AERs measured by the different techniques. The median nighttime AER in all...... studied the pollutant distribution from one room (source room) and interzonal airflows across the dwellings. The air within a given floor was well mixed, with the average tracer gas concentration in the non-source rooms reaching approximately 70% of the source room concentration. There was less air...

  16. A newly developed grab sampling system for collecting stratospheric air over Antarctica

    Directory of Open Access Journals (Sweden)

    Hideyuki Honda

    1996-07-01

    Full Text Available In order to measure the concentrations of various minor constituents and their isotopic ratios in the stratosphere over Antarctica, a simple grab sampling system was newly developed. The sampling system was designed to be launched by a small number of personnel using a rubber balloon under severe experimental conditions. Special attention was paid to minimize the contamination of sample air, as well as to allow easy handling of the system. The sampler consisted mainly of a 15l sample container with electromagnetic and manual valves, control electronics for executing the air sampling procedures and sending the position and status information of the sampler to the ground station, batteries and a transmitter. All these parts were assembled in an aluminum frame gondola with a shock absorbing system for landing. The sampler was equipped with a turn-over mechanism of the gondola to minimize contamination from the gondola, as well as with a GPS receiver and a rawinsonde for its tracking. Total weight of the sampler was about 11kg. To receive, display and store the position and status data of the sampling system at the ground station, a simple data acquisition system with a portable receiver and a microcomputer was also developed. A new gas handling system was prepared to simplify the injection of He gas into the balloon. For air sampling experiments, three sampling systems were launched at Syowa Station (69°00′S, 39°35′E, Antarctica and then recovered on sea ice near the station on January 22 and 25,1996.

  17. CFD Analysis on the Passive Heat Removal by Helium and Air in the Canister of Spent Fuel Dry Storage System

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Do Young; Jeong, Ui Ju; Kim, Sung Joong [Hanyang University, Seoul (Korea, Republic of)

    2016-05-15

    In the current commercial design, the canister of the dry storage system is mainly backfilled with helium gas. Helium gas shows very conductive behavior due to high thermal conductivity and small density change with temperature. However, other gases such as air, argon, or nitrogen are expected to show effective convective behavior. Thus these are also considered as candidates for the backfill gas to provide effective coolability. In this study, to compare the dominant cooling mechanism and effectiveness of cooling between helium gas and air, a computational fluid dynamics (CFD) analysis for the canister of spent fuel dry storage system with backfill gas of helium and air is carried out. In this study, CFD simulations for the helium and air backfilled gas for dry storage system canister were carried out using ANSYS FLUENT code. For the comparison work, two backfilled fluids were modeled with same initial and boundary conditions. The observed major difference can be summarized as follows. - The simulation results showed the difference in dominant heat removal mechanism. Conduction for helium, and convection for air considering Reynolds number distribution. - The temperature gradient inside the fuel assembly showed that in case of air, more effective heat mixing occurred compared to helium.

  18. Ten-year mortality in a sample of an adult population in relation to air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Krzyzanowski, M; Wojtyniak, B

    1982-12-01

    The 10-year mortality in a sample of adult inhabitants of Cracow, Poland, was analysed according to the levels of air pollution in the area of residence. Smoking habit and several social and occupational factors were considered in the analysis, which was carried out with the use of a multivariate method for categorical variables. Among men the main effect of air pollution was marginally significant, but there was a significant interaction between air pollution and smoking. Among women no such relation could be detected. Also, the association between female mortality and smoking was not significant. From other factors considered in the analysis, only exposure at work to dust, high humidity, and variable temperature was related to mortality in both men and women. In addition among women higher mortality was related to a lower level of education.

  19. Measurement of Air Pollutants in the Troposphere

    Science.gov (United States)

    Clemitshaw, Kevin C.

    2011-01-01

    This article describes the principles, applications and performances of methods to measure gas-phase air pollutants that either utilise passive or active sampling with subsequent laboratory analysis or involve automated "in situ" sampling and analysis. It focuses on air pollutants that have adverse impacts on human health (nitrogen…

  20. Air exposure and sample storage time influence on hydrogen release from tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Moshkunov, K.A., E-mail: moshkunov@gmail.co [National Research Nuclear University ' MEPhI' , Kashirskoe sh. 31, 115409 Moscow (Russian Federation); Schmid, K.; Mayer, M. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Kurnaev, V.A.; Gasparyan, Yu.M. [National Research Nuclear University ' MEPhI' , Kashirskoe sh. 31, 115409 Moscow (Russian Federation)

    2010-09-30

    In investigations of hydrogen retention in first wall components the influence of the conditions of the implanted target storage prior to analysis and the storage time is often neglected. Therefore we have performed a dedicated set of experiments. The release of hydrogen from samples exposed to ambient air after irradiation was compared to samples kept in vacuum. For air exposed samples significant amounts of HDO and D{sub 2}O are detected during TDS. Additional experiments have shown that heavy water is formed by recombination of releasing D and H atoms with O on the W surface. This water formation can alter hydrogen retention results significantly, in particular - for low retention cases. In addition to the influence of ambient air exposure also the influence of storage time in vacuum was investigated. After implantation at 300 K the samples were stored in vacuum for up to 1 week during which the retained amount decreased significantly. The subsequently measured TDS spectra showed that D was lost from both the high and low energy peaks during storage at ambient temperature of {approx}300 K. An attempt to simulate this release from both peaks during room temperature storage by TMAP 7 calculations showed that this effect cannot be explained by conventional diffusion/trapping models.

  1. Air exposure and sample storage time influence on hydrogen release from tungsten

    International Nuclear Information System (INIS)

    Moshkunov, K.A.; Schmid, K.; Mayer, M.; Kurnaev, V.A.; Gasparyan, Yu.M.

    2010-01-01

    In investigations of hydrogen retention in first wall components the influence of the conditions of the implanted target storage prior to analysis and the storage time is often neglected. Therefore we have performed a dedicated set of experiments. The release of hydrogen from samples exposed to ambient air after irradiation was compared to samples kept in vacuum. For air exposed samples significant amounts of HDO and D 2 O are detected during TDS. Additional experiments have shown that heavy water is formed by recombination of releasing D and H atoms with O on the W surface. This water formation can alter hydrogen retention results significantly, in particular - for low retention cases. In addition to the influence of ambient air exposure also the influence of storage time in vacuum was investigated. After implantation at 300 K the samples were stored in vacuum for up to 1 week during which the retained amount decreased significantly. The subsequently measured TDS spectra showed that D was lost from both the high and low energy peaks during storage at ambient temperature of ∼300 K. An attempt to simulate this release from both peaks during room temperature storage by TMAP 7 calculations showed that this effect cannot be explained by conventional diffusion/trapping models.

  2. Air exposure and sample storage time influence on hydrogen release from tungsten

    Science.gov (United States)

    Moshkunov, K. A.; Schmid, K.; Mayer, M.; Kurnaev, V. A.; Gasparyan, Yu. M.

    2010-09-01

    In investigations of hydrogen retention in first wall components the influence of the conditions of the implanted target storage prior to analysis and the storage time is often neglected. Therefore we have performed a dedicated set of experiments. The release of hydrogen from samples exposed to ambient air after irradiation was compared to samples kept in vacuum. For air exposed samples significant amounts of HDO and D 2O are detected during TDS. Additional experiments have shown that heavy water is formed by recombination of releasing D and H atoms with O on the W surface. This water formation can alter hydrogen retention results significantly, in particular - for low retention cases. In addition to the influence of ambient air exposure also the influence of storage time in vacuum was investigated. After implantation at 300 K the samples were stored in vacuum for up to 1 week during which the retained amount decreased significantly. The subsequently measured TDS spectra showed that D was lost from both the high and low energy peaks during storage at ambient temperature of ˜300 K. An attempt to simulate this release from both peaks during room temperature storage by TMAP 7 calculations showed that this effect cannot be explained by conventional diffusion/trapping models.

  3. Effects of passive smoking in the work place on expiration air carbon monoxide (Co) and carboxihemoglobin (cohb) levels: results of a survey in Turkey

    International Nuclear Information System (INIS)

    Acimis, N.M.; Bostanci, M.; Ergin, A.; Bozkurt, A.Y.; Ozsahin, A.

    2009-01-01

    To assess the prevalence of smoking and the effects of passive smoking among bank employees. This cross-sectional study was conducted between 2001 and 2002. Data was collected through questionnaire. The level of Carbon Monoxide (CO) and the percentage of Carboxihemoglobin (COHb) level in the blood were measured by using Bend fond Pico Smokerlyser. Chi-square and ANOVA were used. Six hundred fifty four respondents participated in the study which included 384 (58.7%) male and 267 (40.6%) female. The mean value for CO in the expiration air was 14.57+-11.1 ppm [(18.49 +- 11.21, 7.74 +- 5.71 and 4.85 +- 2.35; for current smokers, non-smokers with current exposure and non-smokers without current exposure, respectively (p<0.001)]. The mean value for COHb % was 2.97 +- 1.9 [(3.60 +- 1.88, 1.80 +- 1.17 and 1.21 +- 0.99; for current smokers, non-smokers with current exposure and non-smokers without current exposure, respectively (p<0.001)]. Passive smoking is still a significant health problem in the work place. Anti-tobacco implementations should be carried out strictly in all work places. (author)

  4. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample.

    Science.gov (United States)

    Lee, Kil Yong; Burnett, William C

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.

  5. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample

    International Nuclear Information System (INIS)

    Kil Yong Lee; Burnett, W.C.

    2013-01-01

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 deg C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods. (author)

  6. Environmental and emergency response capabilities of Los Alamos Scientific Laboratory's radiological air sampling program

    International Nuclear Information System (INIS)

    Gunderson, T.C.

    1980-05-01

    Environmental and emergency response radiological air sampling capabilities of the Environmental Surveillance Group at Los Alamos Scientific Laboratory are described. The air sampling program provides a supplementary check on the adequacy of containment and effluent controls, determines compliance with applicable protection guides and standards, and assesses potential environmental impacts on site environs. It also allows evaluation of potential individual and total population doses from airborne radionuclides that may be inhaled or serve as a source of external radiation. The environmental program is sufficient in scope to detect fluctuations and long-term trends in atmospheric levels of radioactivity originating onsite. The emergency response capabilities are designed to respond to both onsite unplanned releases and atmospheric nuclear tests

  7. A passive sampler for atmospheric ozone

    International Nuclear Information System (INIS)

    Grosjean, D.; Hisham, M.W.M.

    1992-01-01

    A simple, cost-effective passive sampler has been developed for the determination of atmospheric ozone. This passive sampler is based on a colorant which fades upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Direct, on-site measurements are possible, and no chemical analyses are needed. Sampler design and validation studies have been carried out and included quantitative determination of color change vs exposure time (1-8 days), color change vs. ozone concentration (30-350 ppb), and response to changes in sampler configuration that modify the passive sampling rate. With indigo carmine as the colorant, the detection limits are 30 ppb. day and 120 ppb. day using a plastic grid and Teflon filter, respectively, as diffusion barriers. Interferences from nitrogen dioxide, formaldehyde and peroxyacetyl nitrate are 15, 4 and 16%, respectively, thus resulting in a negligible bias when measuring ozone in ambient air

  8. Measurement of the Tracer Gradient and Sampling System Bias of the Hot Fuel Examination Facility Stack Air Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.; Flaherty, Julia E.

    2011-07-20

    This report describes tracer gas uniformity and bias measurements made in the exhaust air discharge of the Hot Fuel Examination Facility at Idaho National Laboratory. The measurements were a follow-up on earlier measurements which indicated a lack of mixing of the two ventilation streams being discharged via a common stack. The lack of mixing is detrimental to the accuracy of air emission measurements. The lack of mixing was confirmed in these new measurements. The air sampling probe was found to be out of alignment and that was corrected. The suspected sampling bias in the air sample stream was disproved.

  9. Technical assessment of workplace air sampling requirements at tank farm facilities. Revision 1

    International Nuclear Information System (INIS)

    Olsen, P.A.

    1994-01-01

    WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE N 5480.6 ''US Department of Energy Radiological Control Manual'' as it applies to programs at Hanford which are now overseen by WHC. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ''Hanford Site Radiological Control Manual'' and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of Tank Farms' workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance

  10. Technical assessment of TRUSAF for compliance with work place air sampling. Revision 1

    International Nuclear Information System (INIS)

    Butler, J.D.

    1995-01-01

    The purpose of this Technical Work Document is to satisfy WHC-CM-1-6, the ''WHC Radiological Control Manual.'' This first revision of the original Supporting Document covers the period from January 1, 1994 to December 31, 1994. WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ''Hanford Site Radiological Control Manual'' and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. this document also provides an evaluation of the compliance of the TRUSAF workplace air sampling program to the criteria, standards, and requirements and documents. Where necessary, it also indicates changes needed to bring specific locations into compliance

  11. 2017 Annual Terrestrial Sampling Plan for Sandia National Laboratories/New Mexico on Kirtland Air Force Base

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, Stacy R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-02-01

    The 2017 Annual Terrestrial Sampling Plan for Sandia National Laboratories/New Mexico on Kirtland Air Force Base has been prepared in accordance with the “Letter of Agreement Between Department of Energy, National Nuclear Security Administration, Sandia Field Office (DOE/NNSA/SFO) and 377th Air Base Wing (ABW), Kirtland Air Force Base (KAFB) for Terrestrial Sampling” (signed January 2017), Sandia National Laboratories, New Mexico (SNL/NM). The Letter of Agreement requires submittal of an annual terrestrial sampling plan.

  12. 2018 Annual Terrestrial Sampling Plan for Sandia National Laboratories/New Mexico on Kirtland Air Force Base.

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, Stacy R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-01-01

    The 2018 Annual Terrestrial Sampling Plan for Sandia National Laboratories/New Mexico on Kirtland Air Force Base has been prepared in accordance with the “Letter of Agreement Between Department of Energy, National Nuclear Security Administration, Sandia Field Office (DOE/NNSA/SFO) and 377th Air Base Wing (ABW), Kirtland Air Force Base (KAFB) for Terrestrial Sampling” (signed January 2017), Sandia National Laboratories, New Mexico (SNL/NM). The Letter of Agreement requires submittal of an annual terrestrial sampling plan.

  13. CO2 isotope analyses using large air samples collected on intercontinental flights by the CARIBIC Boeing 767

    NARCIS (Netherlands)

    Assonov, S.S.; Brenninkmeijer, C.A.M.; Koeppel, C.; Röckmann, T.

    2009-01-01

    Analytical details for 13C and 18O isotope analyses of atmospheric CO2 in large air samples are given. The large air samples of nominally 300 L were collected during the passenger aircraft-based atmospheric chemistry research project CARIBIC and analyzed for a large number of trace gases and

  14. Experimental study of the heat transfers and passive cooling potential of a ventilated plenum designed for uniform air distribution

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Lessing, Julian

    2016-01-01

    suspended ceiling to uniformly distribute the supply air to the occupied zone. This, in effect, increases the thermal mass of the room because the upper slab of the room no longer is isolated from the occupied zone. In this study, the cooling potential of a diffuse ceiling ventilation system is i...

  15. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    Directory of Open Access Journals (Sweden)

    Cesar A Corzo

    Full Text Available Airborne transmission of influenza A virus (IAV in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  16. Comparison of air samples, nasal swabs, ear-skin swabs and environmental dust samples for detection of Methicillin Resistant Staphylococcus aureus (MRSA) in pig herds

    DEFF Research Database (Denmark)

    Agersø, Yvonne; Vigre, Håkan; Cavaco, Lina

    2014-01-01

    To identify a cost-effective and practical method for detection of methicillin-resistant Staphylococcus aureus (MRSA) in pig herds, the relative sensitivity of four sample types: nasal swabs, ear-skin (skin behind the ears) swabs, environmental dust swabs and air was compared. Moreover, dependency......-herd prevalence ⩾25%]. The results indicate that taking swabs of skin behind the ears (ten pools of five) was even more sensitive than taking nasal swabs (ten pools of five) at the herd level and detected significantly more positive samples. spa types t011, t034 and t4208 were observed. In conclusion, MRSA...... detection by air sampling is easy to perform, reduces costs and analytical time compared to existing methods, and is recommended for initial testing of herds. Ear-skin swab sampling may be more sensitive for MRSA detection than air sampling or nasal swab sampling....

  17. Urban air quality assessment using monitoring data of fractionized aerosol samples, chemometrics and meteorological conditions.

    Science.gov (United States)

    Yotova, Galina I; Tsitouridou, Roxani; Tsakovski, Stefan L; Simeonov, Vasil D

    2016-01-01

    The present article deals with assessment of urban air by using monitoring data for 10 different aerosol fractions (0.015-16 μm) collected at a typical urban site in City of Thessaloniki, Greece. The data set was subject to multivariate statistical analysis (cluster analysis and principal components analysis) and, additionally, to HYSPLIT back trajectory modeling in order to assess in a better way the impact of the weather conditions on the pollution sources identified. A specific element of the study is the effort to clarify the role of outliers in the data set. The reason for the appearance of outliers is strongly related to the atmospheric condition on the particular sampling days leading to enhanced concentration of pollutants (secondary emissions, sea sprays, road and soil dust, combustion processes) especially for ultra fine and coarse particles. It is also shown that three major sources affect the urban air quality of the location studied-sea sprays, mineral dust and anthropogenic influences (agricultural activity, combustion processes, and industrial sources). The level of impact is related to certain extent to the aerosol fraction size. The assessment of the meteorological conditions leads to defining of four downwind patterns affecting the air quality (Pelagic, Western and Central Europe, Eastern and Northeastern Europe and Africa and Southern Europe). Thus, the present study offers a complete urban air assessment taking into account the weather conditions, pollution sources and aerosol fractioning.

  18. Use of passive diffusion sampling method for defining NO2 concentrations gradient in São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Meliefste Kees

    2006-06-01

    Full Text Available Abstract Background Air pollution in São Paulo is constantly being measured by the State of Sao Paulo Environmental Agency, however there is no information on the variation between places with different traffic densities. This study was intended to identify a gradient of exposure to traffic-related air pollution within different areas in São Paulo to provide information for future epidemiological studies. Methods We measured NO2 using Palmes' diffusion tubes in 36 sites on streets chosen to be representative of different road types and traffic densities in São Paulo in two one-week periods (July and August 2000. In each study period, two tubes were installed in each site, and two additional tubes were installed in 10 control sites. Results Average NO2 concentrations were related to traffic density, observed on the spot, to number of vehicles counted, and to traffic density strata defined by the city Traffic Engineering Company (CET. Average NO2concentrations were 63μg/m3 and 49μg/m3 in the first and second periods, respectively. Dividing the sites by the observed traffic density, we found: heavy traffic (n = 17: 64μg/m3 (95% CI: 59μg/m3 – 68μg/m3; local traffic (n = 16: 48μg/m3 (95% CI: 44μg/m3 – 52μg/m3 (p Conclusion The differences in NO2 levels between heavy and local traffic sites are large enough to suggest the use of a more refined classification of exposure in epidemiological studies in the city. Number of vehicles counted, traffic density observed on the spot and traffic density strata defined by the CET might be used as a proxy for traffic exposure in São Paulo when more accurate measurements are not available.

  19. SUBMERGED GRAVEL SCRUBBER DEMONSTRATION AS A PASSIVE AIR CLEANER FOR CONTAINMENT VENTING AND PURGING WITH SODIUM AEROSOLS -- CSTF TESTS AC7 - AC10

    Energy Technology Data Exchange (ETDEWEB)

    HILLIARD, R K.; MCCORMACK, J D.; POSTMA, A K.

    1981-11-01

    Four large-scale air cleaning tests (AC7 - AC10) were performed in the Containment Systems Test Facility (CS'lF) to demonstrate the performance of a Submerged Gravel Scrubber for cleaning the effluent gas from a vented and purged breeder reactor containment vessel. The test article, comprised of a Submerged Gravel Scrubber (SGS) followed by a high efficiency fiber demister, had a design gas flow rate of 0.47 m{sup 3}/s (1000 ft{sup 3}/min) at a pressure drop of 9.0 kPa (36 in. H{sub 2}O). The test aerosol was sodium oxide, sodium hydroxide, or sodium carbonate generated in the 850-m{sup 3} CSTF vessel by continuously spraying sodium into the air-filled vessel while adding steam or carbon dioxide. Approximately 4500 kg (10,000 lb) of sodium was sprayed over a total period of 100 h during the tests. The SGS/Demister system was shown to be highly efficient (removing ~99.98% of the entering sodium aerosol mass), had a high mass loading capacity, and operated in a passive manner, with no electrical requirement. Models for predicting aerosol capture, gas cooling, and pressure drop are developed and compared with experimental results.

  20. Passive control potentials of trees and on-street parked cars in reduction of air pollution exposure in urban street canyons

    International Nuclear Information System (INIS)

    Abhijith, K.V.; Gokhale, Sharad

    2015-01-01

    This study investigates the passive-control-potentials of trees and on-street parked cars on pedestrian exposure to air pollutants in a street canyon using three-dimensional CFD. Since, according to some studies trees deteriorate air quality and cars parked roadside improve it, the combine as well as separate effects of trees and on-street parked cars have been examined. For this, different tree canopy layouts and parking configurations have been developed and pedestrian exposure for each has been analysed. The results showed, for example, tree crown with high porosity and low-stand density in combination with parallel or perpendicular car parking reduced the pedestrian exposure considerably. - Highlights: • Trees and on-street parked cars can manipulate pollutant levels in street canyons. • Low stand density trees with 0° or 90° car parking reduce pedestrian exposure. • Trees with medium crown, high porosity, low stand density reduce pollutant levels. - This study investigated the combination of trees and on-street parked cars to manipulate pollutant levels in urban street canyons to reduce pedestrian exposure

  1. High efficiency mixed species radioiodine air sampling, readout, and dose assessment system

    International Nuclear Information System (INIS)

    Distenfeld, C.; Klemish, J.

    1976-05-01

    Reactor accidents require monitoring to assess the impact to persons in the environment. This implies methods and apparatus to accurately and economically sample and evaluate possible released activity. The development of a prototype iodine air sampling system that can differentiate against noble gas activity and be evaluated by standard Civil Defense instrumentation is reported. The apparatus can efficiently (95 percent) collect organic or inorganic, particulate or gaseous radioiodine in concentrations below stable atmospheric iodine, and under severe ambient conditions. Response to noble fission gases was reduced to less than 4 x 10 -4 of an equal iodine airborne activity by heating the collector to approximately 100 0 C. Reliable sample size, +-5 percent, was achieved by using a simple air flow regulator. Thyroid dose commitment was mathematically and graphically related to the iodine isotope distribution expected in the environment and to the response of the Civil Defense CDV-700 instrument used to evaluate the sample. Sensitivity of the method allows dose assessment of 1 to 2 rads to a child's thyroid

  2. Radiological air monitoring and sample analysis research and development progress report

    International Nuclear Information System (INIS)

    1992-01-01

    Sponsored by a Department Of Energy (DOE) research and development grant, the State of Idaho INEL Oversight Program (OP) personnel designed an independent air monitoring system that provides detection of the presence of priority airborne contaminants potentially migrating beyond INEL boundaries. Initial locations for off-site ambient air monitoring stations were chosen in consultation with: DOE and NOAA reports; Mesodif modeling; review of the relevant literature; and communication with private contractors and experts in pertinent fields. Idaho State University (ISU) has initiated an Environmental Monitoring Program (EMP). The EMP provides an independent monitoring function as well as a training ground for students. Students learn research techniques dedicated to environmental studies and learn analytical skills and rules of compliance related to monitoring. ISU-EMP assisted OP in specific aspects of identifying optimum permanent monitoring station locations, and in selecting appropriate sample collection equipment for each station. The authorization to establish, prepare and install sampling devices on selected sites was obtained by OP personnel in conjunction with ISU-EMP personnel. All samples described in this program are collected by OP or ISU-EMP personnel and returned to the ISU for analysis. This report represents the summary of results of those samples collected and analyzed for radioactivity during the year of 1992

  3. An assessment of air sampling location for stack monitoring in nuclear facility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Bok [University of Science and Technology, Daejeon (Korea, Republic of); Kim, Tae Hyoung; Lee, Jong Il; Kim, Bong Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-06-15

    In this study, air sampling locations in the stack of the Advanced Fuel Science Building (AFSB) at the Korea Atomic Energy Research Institute (KAERI) were assessed according to the ANSI/HPS N13.1-1999 specification. The velocity profile, flow angle and 10 μm aerosol particle profile at the cross-section as functions of stack height L and stack diameter D (L/D) were assessed according to the sampling location criteria using COMSOL. The criteria for the velocity profile were found to be met at 5 L/D or more for the height, and the criteria for the average flow angle were met at all locations through this assessment. The criteria for the particle profile were met at 5 L/D and 9 L/D. However, the particle profile at the cross-section of each sampling location was found to be non-uniform. In order to establish uniformity of the particle profile, a static mixer and a perimeter ring were modeled, after which the degrees of effectiveness of these components were compared. Modeling using the static mixer indicated that the sampling locations that met the criteria for the particle profile were 5-10 L/D. When modeling using the perimeter ring, the sampling locations that met the criteria for particle profile were 5 L/D and 7-10 L/D. The criteria for the velocity profile and the average flow angle were also met at the sampling locations that met the criteria for the particle profile. The methodologies used in this study can also be applied during assessments of air sampling locations when monitoring stacks at new nuclear facilities as well as existing nuclear facilities.

  4. Mass spectrometry of solid samples in open air using combined laser ionization and ambient metastable ionization

    International Nuclear Information System (INIS)

    He, X.N.; Xie, Z.Q.; Gao, Y.; Hu, W.; Guo, L.B.; Jiang, L.; Lu, Y.F.

    2012-01-01

    Mass spectrometry of solid samples in open air was carried out using combined laser ionization and metastable ionization time-of-flight mass spectrometry (LI-MI-TOFMS) in ambient environment for qualitative and semiquantitative (relative analyte information, not absolute information) analysis. Ambient metastable ionization using a direct analysis in realtime (DART) ion source was combined with laser ionization time-of-flight mass spectrometry (LI-TOFMS) to study the effects of combining metastable and laser ionization. A series of metallic samples from the National Institute of Standards and Technology (NIST 494, 495, 498, 499, and 500) and a pure carbon target were characterized using LI-TOFMS in open air. LI-MI-TOFMS was found to be superior to laser-induced breakdown spectroscopy (LIBS). Laser pulse energies between 10 and 200 mJ at the second harmonic (532 nm) of an Nd:YAG laser were applied in the experiment to obtain a high degree of ionization in plasmas. Higher laser pulse energy improves signal intensities of trace elements (such as Fe, Cr, Mn, Ni, Ca, Al, and Ag). Data were analyzed by numerically calculating relative sensitivity coefficients (RSCs) and limit of detections (LODs) from mass spectrometry (MS) and LIBS spectra. Different parameters, such as boiling point, ionization potential, RSC, LOD, and atomic weight, were shown to analyze the ionization and MS detection processes in open air.

  5. Passive House Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Strom, I.; Joosten, L.; Boonstra, C. [DHV Sustainability Consultants, Eindhoiven (Netherlands)

    2006-05-15

    PEP stands for 'Promotion of European Passive Houses' and is a consortium of European partners, supported by the European Commission, Directorate General for Energy and Transport. In this working paper an overview is given of Passive House solutions. An inventory has been made of Passive House solutions for new build residences applied in each country. Based on this, the most common basic solutions have been identified and described in further detail, including the extent to which solutions are applied in common and best practice and expected barriers for the implementation in each country. An inventory per country is included in the appendix. The analysis of Passive House solutions in partner countries shows high priority with regard to the performance of the thermal envelope, such as high insulation of walls, roofs, floors and windows/ doors, thermal bridge-free construction and air tightness. Due to the required air tightness, special attention must be paid to indoor air quality through proper ventilation. Finally, efficient ((semi-)solar) heating systems for combined space and DHW heating still require a significant amount of attention in most partner countries. Other basic Passive House solutions show a smaller discrepancy with common practice and fewer barriers have been encountered in partner countries. In the next section, the general barriers in partner countries have been inventoried. For each type of barrier a suggested approach has been given. Most frequently encountered barriers in partner countries are: limited know-how; limited contractor skills; and acceptation of Passive Houses in the market. Based on the suggested approaches to overcoming barriers, this means that a great deal of attention must be paid to providing practical information and solutions to building professionals, providing practical training to installers and contractors and communication about the Passive House concept to the market.

  6. Glyphosate–rich air samples induce IL–33, TSLP and generate IL–13 dependent airway inflammation

    Science.gov (United States)

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M.; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A.; Adhikari, Atin

    2014-01-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4−/−, and IL-13−/− mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease. PMID:25172162

  7. Simultaneous multicopter-based air sampling and sensing of meteorological variables

    Science.gov (United States)

    Brosy, Caroline; Krampf, Karina; Zeeman, Matthias; Wolf, Benjamin; Junkermann, Wolfgang; Schäfer, Klaus; Emeis, Stefan; Kunstmann, Harald

    2017-08-01

    The state and composition of the lowest part of the planetary boundary layer (PBL), i.e., the atmospheric surface layer (SL), reflects the interactions of external forcing, land surface, vegetation, human influence and the atmosphere. Vertical profiles of atmospheric variables in the SL at high spatial (meters) and temporal (1 Hz and better) resolution increase our understanding of these interactions but are still challenging to measure appropriately. Traditional ground-based observations include towers that often cover only a few measurement heights at a fixed location. At the same time, most remote sensing techniques and aircraft measurements have limitations to achieve sufficient detail close to the ground (up to 50 m). Vertical and horizontal transects of the PBL can be complemented by unmanned aerial vehicles (UAV). Our aim in this case study is to assess the use of a multicopter-type UAV for the spatial sampling of air and simultaneously the sensing of meteorological variables for the study of the surface exchange processes. To this end, a UAV was equipped with onboard air temperature and humidity sensors, while wind conditions were determined from the UAV's flight control sensors. Further, the UAV was used to systematically change the location of a sample inlet connected to a sample tube, allowing the observation of methane abundance using a ground-based analyzer. Vertical methane gradients of about 0.3 ppm were found during stable atmospheric conditions. Our results showed that both methane and meteorological conditions were in agreement with other observations at the site during the ScaleX-2015 campaign. The multicopter-type UAV was capable of simultaneous in situ sensing of meteorological state variables and sampling of air up to 50 m above the surface, which extended the vertical profile height of existing tower-based infrastructure by a factor of 5.

  8. Equilibrium passive sampling as a tool to study polycyclic aromatic hydrocarbons in Baltic Sea sediment pore-water systems

    DEFF Research Database (Denmark)

    Lang, Susann-Cathrin; Hursthouse, Andrew; Mayer, Philipp

    2015-01-01

    Solid Phase Microextraction (SPME) was applied to provide the first large scale dataset of freely dissolved concentrations for 9 polycyclic aromatic hydrocarbons (PAHs) in Baltic Sea sediment cores. Polydimethylsiloxane (PDMS) coated glass fibers were used for ex-situ equilibrium sampling followed...

  9. Radiation damage of paper samples in in-air PIXE analysis

    International Nuclear Information System (INIS)

    Matsuyama, S.; Endo, H.; Ishii, K.; Yamazaki, H.; Tokai, Y.; Sugimoto, A.; Yamamoto, K.; Satoh, T.; Orihara, H.

    1999-01-01

    Degradation of paper caused by beam irradiation was investigated from a viewpoint of discoloration in PIXE analysis and its application to the paper samples of archaeology. Two types of paper (Japanese paper and fine quality paper) were tested in in-air PIXE analysis with 3 MeV protons. The degree of discoloration was quantitatively measured by the use of a colorimeter. The degree of discoloration was different for each tested paper and corresponded to the radiation dose of ions. It is resulted that even the in-air PIXE analysis should be carefully applied to archaeological treasures. Because discoloration of all tested paper decreased gradually at first but then increased after a few weeks. However, this phenomenon can be used to develop a technique of funny coloration. (author)

  10. Radiation damage of paper samples in in-air PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, S.; Endo, H.; Ishii, K.; Yamazaki, H.; Tokai, Y.; Sugimoto, A.; Yamamoto, K.; Satoh, T. [Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Miyagi (Japan); Orihara, H. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center

    1999-07-01

    Degradation of paper caused by beam irradiation was investigated from a viewpoint of discoloration in PIXE analysis and its application to the paper samples of archaeology. Two types of paper (Japanese paper and fine quality paper) were tested in in-air PIXE analysis with 3 MeV protons. The degree of discoloration was quantitatively measured by the use of a colorimeter. The degree of discoloration was different for each tested paper and corresponded to the radiation dose of ions. It is resulted that even the in-air PIXE analysis should be carefully applied to archaeological treasures. Because discoloration of all tested paper decreased gradually at first but then increased after a few weeks. However, this phenomenon can be used to develop a technique of funny coloration. (author)

  11. Application of passive sampling in assessing the occurrence and risk of antibiotics and endocrine disrupting chemicals in the Yangtze Estuary, China.

    Science.gov (United States)

    Shi, X; Zhou, J L; Zhao, H; Hou, L; Yang, Y

    2014-09-01

    Polar organic chemical integrative sampler (POCIS) was used in assessing the occurrence and risk of 12 widely used antibiotics and 5 most potent endocrine disrupting chemicals (EDCs) in the Yangtze Estuary, China. During laboratory validation, the kinetics of pollutant uptake by POCIS were linear, and the sampling rates of most compounds were raised by flow rate and salinity, reaching the highest values at salinity 14‰. The sampling rates varied with the target compounds with the EDCs showing the highest values (overall average=0.123Ld(-1)), followed by chloramphenicols (0.100Ld(-1)), macrolides (0.089Ld(-1)), and finally sulfonamides (0.056Ld(-1)). Validation in the Yangtze Estuary in 2013 showed that the field sampling rates were significantly greater for all compounds except bisphenol A, in comparison to laboratory results, and high-frequency spot sampling is critical for fully validating the passive sampler. The field studies show that antibiotics were widely detected in the Yangtze Estuary, with concentrations varying from below quantification to 1613ngL(-1), suggesting their widespread use and persistence in estuarine waters. The dominating pollutants in July were sulfonamides with a total concentration of 258ngL(-1) and in October were macrolides with a total concentration of 350ngL(-1). The calculation of risk quotient suggested that sulfapyridine, sulfaquinoxaline and erythromycin-H2O may have caused medium damage to sensitive organisms such as fish. Copyright © 2014. Published by Elsevier Ltd.

  12. Passiv-Sammler

    OpenAIRE

    Fritsche, U.

    1991-01-01

    The invention relates to a passive collector for air pollution for the determination of emission rates for dry and wet deposits on construction materials such as natural stone, whereby the collector has a surrogate surface of the stone under investigation, the surrogate surface being linked to a collecting vessel such that any dry or wet contamination occurring can be collected.

  13. Size selective isocyanate aerosols personal air sampling using porous plastic foams

    International Nuclear Information System (INIS)

    Cong Khanh Huynh; Trinh Vu Duc

    2009-01-01

    As part of a European project (SMT4-CT96-2137), various European institutions specialized in occupational hygiene (BGIA, HSL, IOM, INRS, IST, Ambiente e Lavoro) have established a program of scientific collaboration to develop one or more prototypes of European personal samplers for the collection of simultaneous three dust fractions: inhalable, thoracic and respirable. These samplers based on existing sampling heads (IOM, GSP and cassettes) use Polyurethane Plastic Foam (PUF) according to their porosity to support sampling and separator size of the particles. In this study, the authors present an original application of size selective personal air sampling using chemical impregnated PUF to perform isocyanate aerosols capturing and derivatizing in industrial spray-painting shops.

  14. Demonstration/Validation of the Snap Sampler Passive Groundwater Sampling Device at the Former McClellan Air Force Base

    Science.gov (United States)

    2011-02-01

    calibrated the Hach field colorimeter for analyses of Iron (2). Upon our return to the site, we purchased other needed supplies, calibrated the purge... Colorimeter II test kit following the manufacturer’s guidelines. 5.7.3.2 Laboratory Analyses To obtain a better understanding of the mechanism for...manufacturer’s guidelines were used to calibrate the Hach Colorimeter II for field analyses for Iron (2). B.3.2 Calibration of Laboratory Instruments

  15. Effect of sample digestion, air filter contamination, and post-adsorption on the analysis of trace elements in air particulate matter

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiao Jin [Department of Environment and Climate Change, Environmental Forensic and Analytical Science Section, New South Wales (Australia); Department of Applied Chemistry, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing (China); Wan, Pingyu [Department of Applied Chemistry, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing (China); Foley, Roy [Department of Environment and Climate Change, Environmental Forensic and Analytical Science Section, New South Wales (Australia)

    2012-11-15

    Inductively coupled plasma atomic emission spectrometry and inductively coupled plasma MS are the major analytical tools for trace elements in environmental matrices, however, the underestimate of certain trace elements in analysis of air particulate matter by these two techniques has long been observed. This has been attributed to incomplete sample digestion. Here, we demonstrate that the combined effects of sample digestion, air filter impurities, and post-adsorption of the analytes contribute to the interference of the analysis. Particular attention should be paid to post-adsorption of analytes onto air filters after acid digestion. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Effect of sample digestion, air filter contamination, and post-adsorption on the analysis of trace elements in air particulate matter

    International Nuclear Information System (INIS)

    Yang, Xiao Jin; Wan, Pingyu; Foley, Roy

    2012-01-01

    Inductively coupled plasma atomic emission spectrometry and inductively coupled plasma MS are the major analytical tools for trace elements in environmental matrices, however, the underestimate of certain trace elements in analysis of air particulate matter by these two techniques has long been observed. This has been attributed to incomplete sample digestion. Here, we demonstrate that the combined effects of sample digestion, air filter impurities, and post-adsorption of the analytes contribute to the interference of the analysis. Particular attention should be paid to post-adsorption of analytes onto air filters after acid digestion. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. Demonstration of the AGI Universal Samplers (F.K.A. the GORE Modules) for Passive Sampling of Groundwater

    Science.gov (United States)

    2014-03-27

    and lower Hen- ry’s Law constants are biased low (Anderson 2013). In this instance, me- thyl tert-butyl ether (MTBE) is lost entirely and 1,2...coolers full of ice or blue ice to transport samples to the laboratory. One limitation associated with using the GORE Module is that, like all no- purge...was taken from Dunbar et al. (2001). A regional geologic and geomorphic model was developed for the Aberdeen Prov- ing Ground (APG). Regional

  18. Demonstration of the AGI Universal Samplers (F.K.A. the GORE (registered trademark) Modules) for Passive Sampling of Groundwater

    Science.gov (United States)

    2014-03-01

    and lower Hen- ry’s Law constants are biased low (Anderson 2013). In this instance, me- thyl tert-butyl ether (MTBE) is lost entirely and 1,2...coolers full of ice or blue ice to transport samples to the laboratory. One limitation associated with using the GORE Module is that, like all no- purge...was taken from Dunbar et al. (2001). A regional geologic and geomorphic model was developed for the Aberdeen Prov- ing Ground (APG). Regional

  19. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    International Nuclear Information System (INIS)

    Barnett, J.M.; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-01-01

    Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor(reg s ign) 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R 2 ) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify

  20. Optimizing the use of on-street car parking system as a passive control of air pollution exposure in street canyons by large eddy simulation

    Science.gov (United States)

    Gallagher, J.; Gill, L. W.; McNabola, A.

    2011-03-01

    An investigation was carried out to establish the effectiveness of parked cars in urban street canyons as passive controls on pedestrian pollutant exposure. A numerical model of a generic street canyon was developed using a large eddy simulation (LES) model to compare personal exposure on the footpath with and without the presence of parked cars. Three configurations of car parking systems were investigated (parallel, perpendicular and 45° parking) in addition to the influence of wind speed, wind direction and car parking occupancy. A tracer gas (CO 2) was used as a representative pollutant from vehicular sources within the street canyon models. The results indicated that parked cars may act as a temporary baffle plate between traffic emissions and pedestrians on the footpath. Reductions in exposure of up to 35% and 49% were attained on the leeward and windward footpaths in perpendicular wind conditions, with parallel winds allowing up to 33% pollutant reduction on both footpaths for parallel parking. The perpendicular and 45° car parking configurations investigated proved less successful as passive controls on air pollution exposure and an increase in pollutant concentration occurred in some models. An investigation of parking space occupancy rates was carried out for parallel parked cars. The fraction of parked cars influenced the level of reduction of pollutants on the footpaths with steady reductions in perpendicular winds, yet reductions were only evident for occupancy rates greater than approximately 45% in parallel wind conditions. One negative impact associated with the parked cars study was the increase of pollutant levels on the roadway as the parked cars acted as a baffle wall, which trapped pollutants in the road. The paper underlines the potential of on-street car parking for reducing the personal exposure of pollutants by pedestrians and the optimum parking layout to achieve maximum health protection.

  1. Comparison of air pollution exposures in active vs. passive travel modes in European cities: A quantitative review.

    Science.gov (United States)

    de Nazelle, Audrey; Bode, Olivier; Orjuela, Juan Pablo

    2017-02-01

    Transport microenvironments tend to have higher air pollutant concentrations than other settings most people encounter in their daily lives. The choice of travel modes may affect significantly individuals' exposures; however such considerations are typically not accounted for in exposure assessment used in environmental health studies. In particular, with increasing interest in the promotion of active travel, health impact studies that attempt to estimate potential adverse consequences of potential increased pollutant inhalation during walking or cycling have emerged. Such studies require a quantification of relative exposures in travel modes. The literature on air pollution exposures in travel microenvironments in Europe was reviewed. Studies which measured various travel modes including at least walking or cycling in a simultaneous or quasi-simultaneous design were selected. Data from these studies were harmonized to allow for a quantitative synthesis of the estimates. Ranges of ratios and 95% confidence interval (CI) of air pollution exposure between modes and between background and transportation modes were estimated. Ten studies measuring fine particulate matter (PM 2.5 ), black carbon (BC), ultrafine particles (UFP), and/or carbon monoxide (CO) in the walk, bicycle, car and/or bus modes were included in the analysis. Only three reported on CO and BC and results should be interpreted with caution. Pedestrians were shown to be the most consistently least exposed of all across studies, with the bus, bicycle and car modes on average 1.3 to 1.5 times higher for PM 2.5 ; 1.1 to 1.7 times higher for UFP; and 1.3 to 2.9 times higher for CO; however the 95% CI included 1 for the UFP walk to bus ratio. Only for BC were pedestrians more exposed than bus users on average (bus to walk ratio 0.8), but remained less exposed than those on bicycles or in cars. Car users tended to be the most exposed (from 2.9 times higher than pedestrians for BC down to similar exposures to

  2. HPLC determination of chlorine in air and water samples following precolumn derivatization to 4-bromoacetanilide

    Energy Technology Data Exchange (ETDEWEB)

    Jain, A. (Rani Durgavati Univ., Jabalpur (India). Dept. of Chemistry); Verma, K.K. (Rani Durgavati Univ., Jabalpur (India). Dept. of Chemistry)

    1993-11-01

    Chlorine has been determined in air and water samples by a rapid and sensitive method entailing precolumn derivatization to 4-bromoacetanilide. A mixed potassium bromide - acetanilide reagent was used as a trapping agent for chlorine in air, and for its derivatization. The 4-bromoacetanilide formed was determined by reversed-phase HPLC on an ODS column, using methanol-water, 65:35 (v/v) as mobile phase; detection was at 240 nm. A rectilinear calibration graph was obtained for the range 0.1-30 [mu]g mL[sup -1] chlorine; the limit of detection found to be 0.01 [mu]g mL[sup -1]. The precolumn derivative has been found to have a shelf-life of at least 21 days; this enables the use of the method for samples transported from the field to the analytical laboratory, or the testing of a variety of conditions for chlorine scrubbing studies without the need for immediate analysis of samples. Humic substances do not cause any interference with the proposed method and the presence of nitrite does not lead to artificially high results and consequent misleading conclusions of the presence of high levels of chlorine. (orig.)

  3. HPLC determination of chlorine in air and water samples following precolumn derivatization to 4-bromoacetanilide

    International Nuclear Information System (INIS)

    Jain, A.; Verma, K.K.

    1993-01-01

    Chlorine has been determined in air and water samples by a rapid and sensitive method entailing precolumn derivatization to 4-bromoacetanilide. A mixed potassium bromide - acetanilide reagent was used as a trapping agent for chlorine in air, and for its derivatization. The 4-bromoacetanilide formed was determined by reversed-phase HPLC on an ODS column, using methanol-water, 65:35 (v/v) as mobile phase; detection was at 240 nm. A rectilinear calibration graph was obtained for the range 0.1-30 μg mL -1 chlorine; the limit of detection found to be 0.01 μg mL -1 . The precolumn derivative has been found to have a shelf-life of at least 21 days; this enables the use of the method for samples transported from the field to the analytical laboratory, or the testing of a variety of conditions for chlorine scrubbing studies without the need for immediate analysis of samples. Humic substances do not cause any interference with the proposed method and the presence of nitrite does not lead to artificially high results and consequent misleading conclusions of the presence of high levels of chlorine. (orig.)

  4. Residues of 2, 4-D in air samples from Saskatchewan: 1966-1975.

    Science.gov (United States)

    Grover, R; Kerr, L A; Wallace, K; Yoshida, K; Maybank, J

    1976-01-01

    Residues of 2,4-D (2,4-dichlorophenoxyacetic acid) in air samples from several sampling sites in central and southern Saskatchewan during the spraying seasons in the 1966-68 and 1970-75 periods were determined by gas-liquid chromatographic techniques. Initially, individual esters of 2,4-D were characterized by retention times and confirmed further by co-injection and dual column procedures. Since 1973, however, only total 2,4-D acid levels in air samples have been determined after esterification to the methyl ester and confirmed by gc/ms techniques whenever possible. Up to 50% of the daily samples collected during the spraying season at any of the locations and during any given year contained 2,4-D, with butyl esters being found most frequently. The daily 24-hr mean atmospheric concentrations of 2,4-D ranged from 0.01 to 1.22 mug/m3, 0.01 to 13.50 mug/m3, and 0.05 to 0.59 mug/m3 for the iso-propyl, mixed butyl and iso-octyl esters, respectively. Even when the samples were analysed for the total 2,4-D content, i.e. from 1973 onwards, the maximum level of the total acid reached only 23.14 mug/m3. In any given year and at any of the sampling sites, about 30% of the samples contained less than 0.01 mug/m3 of 2,4-D. In another 40% of the samples, the levels of 2,4-D ranged from 0.01 to 0.099 mug/m3. Only about 30% of the samples contained 2,4-D concentrations higher than 0.1 mug/m3, with only 10% or less exceeding 1 mug/m3. None of the samples, obtained with the high volume particulate sampler, showed any detectable levels of 2,4-D, indicating little or no transport of 2,4-D adsorbed on dust particles or as crystals of amine salts.

  5. Evaluation of active sampling strategies for the determination of 1,3-butadiene in air

    Science.gov (United States)

    Vallecillos, Laura; Maceira, Alba; Marcé, Rosa Maria; Borrull, Francesc

    2018-03-01

    Two analytical methods for determining levels of 1,3-butadiene in urban and industrial atmospheres were evaluated in this study. Both methods are extensively used for determining the concentration of volatile organic compounds in the atmosphere and involve collecting samples by active adsorptive enrichment on solid sorbents. The first method uses activated charcoal as the sorbent and involves liquid desorption with carbon disulfide. The second involves the use of a multi-sorbent bed with two graphitised carbons and a carbon molecular sieve as the sorbent, with thermal desorption. Special attention was paid to the optimization of the sampling procedure through the study of sample volume, the stability of 1,3-butadiene once inside the sampling tube and the humidity effect. In the end, the thermal desorption method showed better repeatability and limits of detection and quantification for 1,3-butadiene than the liquid desorption method, which makes the thermal desorption method more suitable for analysing air samples from both industrial and urban atmospheres. However, sampling must be performed with a pre-tube filled with a drying agent to prevent the loss of the adsorption capacity of the solid adsorbent caused by water vapour. The thermal desorption method has successfully been applied to determine of 1,3-butadiene inside a 1,3-butadiene production plant and at three locations in the vicinity of the same plant.

  6. Application of XAD-2 resin-based passive samplers and SPME–GC–MS/MS analysis for the monitoring of spatial and temporal variations of atmospheric pesticides in Luxembourg

    International Nuclear Information System (INIS)

    Schummer, Claude; Tuduri, Ludovic; Briand, Olivier; Appenzeller, Brice M.; Millet, Maurice

    2012-01-01

    Passive air sampling has been shown to be a very interesting alternative to high-volume sampling by overcoming its disadvantages (size, weight, expensiveness). However, to date, only limited data is available about passive air sampling of current-use pesticides. In order to test if passive samplers allow monitoring of spatial and temporal variations of atmospheric pesticide concentrations, five XAD-2-resin based passive air samplers were deployed at five locations in Luxembourg. Samplers were analyzed using accelerated solvent extraction coupled to solid-phase microextraction and gas chromatography with tandem mass spectrometry. Collected data was used to study the spatial and temporal variations of the concentrations of the compounds. Twenty two pesticides were detected between March and October, while no pesticides were detected from November to February. Highest concentrations were measured on the rural sites, suggesting that the used XAD-2 resin-based passive samplers allow the simultaneous monitoring of multiple current-use pesticides and identifying spatial and temporal variations. - Highlights: ► XAD-2 passive sampling of current-used pesticides. ► Coupling of ASE and SPME–GC–MS/MS for the analysis of pesticides in XAD-2 passive sampling. ► XAD-2 passive samplers suitable for current-used pesticides atmospheric sampling. ► XAD-2 passive samplers suitable for spatial and temporal atmospheric concentrations variations. - XAD-2 passive sampling of current-use pesticides in the atmosphere.

  7. Enhancement of Condensation Heat Transfer Rate of the Air-Steam Mixture on a Passive Condenser System Using Annular Fins

    Directory of Open Access Journals (Sweden)

    Yeong-Jun Jang

    2017-11-01

    Full Text Available This paper presents an experimental investigation on the enhancement of the heat transfer rate of steam condensation on the external surfaces of a vertical tube with annular fins. A cylindrical condenser tube, which is 40 mm in outer diameter and 1000 mm in length, with annular disks of uniform cross-sectional area is fabricated in the manner of ensuring perfect contact between the base surface and fins. A total of 13 annular fins of 80 mm diameter were installed along the tube height in order to increase the effective heat transfer area by 85%. Through a series of condensation tests for the air-steam mixture under natural convection conditions, the heat transfer data was measured in the pressure range of between 2 and 5 bar, and the air mass fraction from 0.3 to 0.7. The rates of heat transfer of the finned tube are compared to those that are measured on a bare tube to demonstrate the enhanced performance by extended surfaces. In addition, based on the experimental results and the characteristics of steam condensation, the applicability of finned tubes to a large condenser system with a bundle layout is evaluated.

  8. The determination of volatile chlorinated hydrocarbons in air. Sampling rate and efficiency of diffuse samplers

    Energy Technology Data Exchange (ETDEWEB)

    Giese, U.; Stenner, H.; Kettrup, A.

    1989-05-01

    When applicating diffusive sampling-systems to workplace air-monitoring it is necessary to know the behaviour of the diffusive-rate and the efficiency in dependence of concentration, exposition time and the type of pollutant. Especially concerning mixtures of pollutants there are negative influences by competition and mutual displacement possible. Diffusive-rate and discovery for CH/sub 2/Cl/sub 2/ and CHCl/sub 3/ were investigated using two different types of diffuse samplers. For this it was necessary to develop suitable defices for standard gas generation and for the exposition of diffusive-samplers to a standard gas mixture. (orig.).

  9. The organic pollutant status of rivers in Bosnia and Herzegovina as determined by a combination of active and passive sampling methods.

    Science.gov (United States)

    Harman, Christopher; Grung, Merete; Djedjibegovic, Jasmina; Marjanovic, Aleksandra; Fjeld, Eirik; Braaten, Hans Fredrik Veiteberg; Sober, Miroslav; Larssen, Thorjørn; Ranneklev, Sissel Brit

    2018-04-15

    There is an overall lack of data concerning the pollution status of Bosnia Herzegovina, which is confounded by fragmented national environmental management. The present study aimed to provide some initial data for concentrations of priority substances in two major Bosnian Rivers, using two types of passive sampler (PS) as well as by using high volume water sampling (HVWS). Overall, concentrations of most persistent organic pollutants (POPs), including polychlorinated biphenyls (PCBs) and legacy pesticides, were shown to be low. However, around the town of Doboj on the Bosna River, concentrations of polycyclic aromatic hydrocarbons (PAH) breached European standards for several compounds and reached 67 ng L -1 for freely dissolved concentrations and 250 ng L -1 for total concentrations. In general, contamination was lower in the Neretva River compared to the Bosna, although for brominated diphenyl ethers (PBDEs), results suggested an active source of PBDEs at one location based on the ratio of congeners 47 and 99. Direct comparisons between the different sampling techniques used are not straightforward, but similar patterns of PAH contamination were shown by HVWS and PS in the Bosna River. There are both scientific and practical considerations when choosing which type of sampling technique to apply, and this should be decided based on the goals of each individual study.

  10. Evaluation of the Level of air Microbial Contamination in some ...

    African Journals Online (AJOL)

    The level of air microbial contamination in some teaching hospitals waste dump site in South Eastern Nigeria was evaluated using the standard microbiological techniques. Passive air sampling was performed using settle plates. The microbial load of the air around the hospitals waste dumpsite, showed high microbial load ...

  11. Estimation of sampling error uncertainties in observed surface air temperature change in China

    Science.gov (United States)

    Hua, Wei; Shen, Samuel S. P.; Weithmann, Alexander; Wang, Huijun

    2017-08-01

    This study examines the sampling error uncertainties in the monthly surface air temperature (SAT) change in China over recent decades, focusing on the uncertainties of gridded data, national averages, and linear trends. Results indicate that large sampling error variances appear at the station-sparse area of northern and western China with the maximum value exceeding 2.0 K2 while small sampling error variances are found at the station-dense area of southern and eastern China with most grid values being less than 0.05 K2. In general, the negative temperature existed in each month prior to the 1980s, and a warming in temperature began thereafter, which accelerated in the early and mid-1990s. The increasing trend in the SAT series was observed for each month of the year with the largest temperature increase and highest uncertainty of 0.51 ± 0.29 K (10 year)-1 occurring in February and the weakest trend and smallest uncertainty of 0.13 ± 0.07 K (10 year)-1 in August. The sampling error uncertainties in the national average annual mean SAT series are not sufficiently large to alter the conclusion of the persistent warming in China. In addition, the sampling error uncertainties in the SAT series show a clear variation compared with other uncertainty estimation methods, which is a plausible reason for the inconsistent variations between our estimate and other studies during this period.

  12. BIBLE A whole-air sampling as a window on Asian biogeochemistry

    Science.gov (United States)

    Elliott, Scott; Blake, Donald R.; Blake, Nicola J.; Dubey, Manvendra K.; Rowland, F. Sherwood; Sive, Barkley C.; Smith, Felisa A.

    2003-02-01

    Asian trace gas and aerosol emissions into carbon, nitrogen, and other elemental cycles will figure prominently in near term Earth system evolution. Atmospheric hydrocarbon measurements resolve numerous chemical species and can be used to investigate sourcing for key geocarriers. A recent aircraft study of biomass burning and lightning (BIBLE A) explored the East Asian atmosphere and was unique in centering on the Indonesian archipelago. Samples of volatile organics taken over/between the islands of Japan, Saipan, Java, and Borneo are here examined as a guide to whole-air-based studies of future Asian biogeochemistry. The midlatitude onshore/offshore pulse and tropical convection strongly influence concentration distributions. As species of increasing molecular weight are considered, rural, combustion, and industrial source regimes emerge. Methane-rich inputs such as waste treatment and rice cultivation are evidenced in the geostrophic outflow. The Indonesian atmosphere is rich in biomass burning markers and also those of vehicular activity. Complexity of air chemistry in the archipelago is a direct reflection of diverse topography, land use, and local economies in a rapidly developing nation. Conspicuous in its absence is the fingerprint for liquefied petroleum gas leakage, but it can be expected to appear as demand for clean fossil fuels rises along with per capita incomes. Combustion tracers indicate high nitrogen mobilization rates, linking regional terrestrial geocycles with open marine ecosystems. Sea to air fluxes are superimposed on continental and marine backgrounds for the methyl halides. However, ocean hot spots are not coordinated and suggest an intricate subsurface kinetics. Levels of long-lived anthropogenic halocarbons attest to the success of international environmental treaties while reactive chlorine containing species track industrial air masses. The dozens of hydrocarbons resolvable by gas chromatographic methods will enable monitoring of

  13. [An AIDS-related cognitive map in a sample of drug abusers in Buenos Aires City].

    Science.gov (United States)

    Kornblit, A L; Bilyk, A

    1990-01-01

    This paper is an approach to AIDS as a topic among a drug abusers sample of the city of Buenos Aires. Research was carried out on the basis of a qualitative methodology. In an attempt at surveying opinions and attitudes of such a sample as regards AIDS (i.e. subjects' cognitive map), 21 drug abusers from three different rehabilitation programs operating in the B.A. area were interviewed. On the basis of the research performed, the authors elaborate communication strategies among drug abusers that would be helpful for authorities engaged in AIDS prevention to adopt. To boost a strategy likely to break up the AIDS-drug association existing in the mind of many an abuser would be highly advisable so that a separation be settled between both representations, thus giving drug abusers a higher motivation for self-care practice.

  14. Ram-air sample collection device for a chemical warfare agent sensor

    Science.gov (United States)

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  15. Air-segmented continuous-flow analysis for molybdenum in various geochemical samples

    International Nuclear Information System (INIS)

    Harita, Y.; Sugiyama, M.; Hori, T.

    2003-01-01

    An air-segmented continuous-flow method has been developed for the determination of molybdenum at ultra trace levels using the catalytic effect of molybdate during the oxidation of L-ascorbic acid by hydrogen peroxide. Incorporation of an on-line ion exchange column improved the tolerance limit for various ions. The detection limits with and without the column were 64 pmol L m1 and 17 pmol L m1 , and the reproducibilities at 10 nmol L m1 were 2.1 % and 0.2 %, respectively. The proposed method was applied to the determination of molybdenum in seawater and lake water as well as in rock and sediment samples. This method has the highest sensitivity among the available literature to our knowledge, and is also convenient for routine analysis of molybdenum in various natural samples. (author)

  16. Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

    International Nuclear Information System (INIS)

    Langton, C. A.; Almond, P. M.

    2013-01-01

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO 4 - in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O 4 - , which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The Cr oxidation front

  17. EPA's Response to the February 2014 Release of Radioactive Material from the Waste Isolation Pilot Plant (WIPP): EPA's WIPP Air Sampling Data from April 2014

    Science.gov (United States)

    In April 2014, U.S. Environmental Protection Agency (EPA) environmental monitoring and assessment team members reviewed DOE's air sampling plan, visited DOE's air samplers and placed air samplers onsite near existing DOE samplers to corroborate results.

  18. Ambient plasma treatment of silicon wafers for surface passivation recovery

    Science.gov (United States)

    Ge, Jia; Prinz, Markus; Markert, Thomas; Aberle, Armin G.; Mueller, Thomas

    2017-08-01

    In this work, the effect of an ambient plasma treatment powered by compressed dry air on the passivation quality of silicon wafers coated with intrinsic amorphous silicon sub-oxide is investigated. While long-time storage deteriorates the effective lifetime of all samples, a short ambient plasma treatment improves their passivation qualities. By studying the influence of the plasma treatment parameters on the passivation layers, an optimized process condition was identified which even boosted the passivation quality beyond its original value obtained immediately after deposition. On the other hand, the absence of stringent requirement on gas precursors, vacuum condition and longtime processing makes the ambient plasma treatment an excellent candidate to replace conventional thermal annealing in industrial heterojunction solar cell production.

  19. Constructing passive houses

    Energy Technology Data Exchange (ETDEWEB)

    Oehler, S. [Oehler Faigle Archkom Solar Architektur, Bretten (Germany)

    2005-07-01

    Everybody can learn to build energy-efficient. It needs theoretical and practical experience. 1997 we built the first freestanding Passive House in Europe, the Passive House Oehler. There had been a lot of questions, starting with the insecurity, whether the calculation program of the Passive House Institute, the PHPP, is working properly in our case. Nobody knew at that time because nobody tried it out before. It took us a lot of time to find out and every detail of the construction hat to be invented to meet the very high demand of thermal quality. All the following houses needed less time and had fewer open questions, adding one piece of experience with every building. 2002 we realised the biggest Passive House, the office building Energon Ulm with 420 working spaces. In the meantime we have learned a lot like how to produce prefabricated timber elements for the facades, providing good insulation, air tightness and avoiding serious thermal bridges. We have proofed, that any kind of building type can be a Passive House. And with increasing experience the freedom of design and construction is growing. Even the economical efficiency increased. The Energon Ulm is providing a much better indoor climate than any other office building and was build 10 % cheaper than an average German office building. At present the Passive House Standard is the most efficient solution for the user to live in the desired comfort zone between 20 C and 25 C. This zone of individual feeling-well can be described with the term ''operative temperature''. This term is defined by factors like air temperature, radiation temperature of warm and cold surfaces, air speed and humidity. The result of all these factors has to be within 18 C to 25 C without accepting one of the factors getting extreme.

  20. Passive Education

    Science.gov (United States)

    Bojesen, Emile

    2018-01-01

    This paper does not present an advocacy of a passive education as opposed to an active education nor does it propose that passive education is in any way 'better' or more important than active education. Through readings of Maurice Blanchot, Jacques Derrida and B.S. Johnson, and gentle critiques of Jacques Rancière and John Dewey, passive…

  1. Evaluation of physical sampling efficiency for cyclone-based personal bioaerosol samplers in moving air environments.

    Science.gov (United States)

    Su, Wei-Chung; Tolchinsky, Alexander D; Chen, Bean T; Sigaev, Vladimir I; Cheng, Yung Sung

    2012-09-01

    The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s(-1)) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.

  2. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Gaikwad, R.H.; Ravi, P.M.; Tripathi, R.M.

    2015-01-01

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241 Am and 90 Sr/ 90 Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  3. Energetic performances of an optimized passive Solar Heating Prototype used for Tunisian buildings air-heating application

    International Nuclear Information System (INIS)

    Mehdaoui, Farah; Hazami, Majdi; Naili, Nabiha; Farhat, Abdelhamid

    2014-01-01

    Highlights: • The study of a Solar Heating Prototype to prevail the buildings air-heating needs. • A parametric study of the system was achieved by means of the TRNSYS program. • The monthly internal temperature during cold months ranges between 22 and 25 °C. • The results shows that the relative humidity inside the monozone room of about 40%. - Abstract: This paper deals with the energetic performances of a Solar Heating Prototype (SHP) conceived in our laboratory to prevail the Tunisian households’ air-heating needs. The conceived SHP mainly consists of a flat-plate solar collector, solar hot water tank and an active layer integrated inside a single room. Firstly, a complete model is formulated taking into account various modes of heat transfer in the SHP by means of the TRNSYS simulation program. To validate the TRNSYS model, experimental tests under local weather conditions were performed for 2 days spread over 2 months (March and April 2013). Predicted results were compared to the measurements in order to determine the accuracy of the simulation program. A parametric study was then achieved by means of the TRNSYS program in order to optimize SHP design parameters (Collector area, collector mass flow rate, floor mass flow rate, storage tank volume and thickness of the active layer). The optimization of all design parameters shows that to achieve a maximum performances from the SHP it is essential to use a solar collector with an area equal to 6 m 2 area, a collector mass flow rate equal to 100 kg h −1 and a hot water storage tank with a capacity equal to 450 l. Concerning the floor heating, the optimal values of mass flow rate and the active layer thickness are 200 kg h −1 and 0.06 m, respectively. The long-term SHP performances were afterward evaluated by means of the Typical Meteorological Year (TMY) data relative to Tunis, Tunisia. Results showed that for an annual total solar insolation of about 6493.37 MJ m −2 the average solar fraction

  4. Adaptive Automation Triggered by EEG-Based Mental Workload Index: A Passive Brain-Computer Interface Application in Realistic Air Traffic Control Environment.

    Science.gov (United States)

    Aricò, Pietro; Borghini, Gianluca; Di Flumeri, Gianluca; Colosimo, Alfredo; Bonelli, Stefano; Golfetti, Alessia; Pozzi, Simone; Imbert, Jean-Paul; Granger, Géraud; Benhacene, Raïlane; Babiloni, Fabio

    2016-01-01

    Adaptive Automation (AA) is a promising approach to keep the task workload demand within appropriate levels in order to avoid both the under - and over-load conditions, hence enhancing the overall performance and safety of the human-machine system. The main issue on the use of AA is how to trigger the AA solutions without affecting the operative task. In this regard, passive Brain-Computer Interface (pBCI) systems are a good candidate to activate automation, since they are able to gather information about the covert behavior (e.g., mental workload) of a subject by analyzing its neurophysiological signals (i.e., brain activity), and without interfering with the ongoing operational activity. We proposed a pBCI system able to trigger AA solutions integrated in a realistic Air Traffic Management (ATM) research simulator developed and hosted at ENAC (É cole Nationale de l'Aviation Civile of Toulouse, France). Twelve Air Traffic Controller (ATCO) students have been involved in the experiment and they have been asked to perform ATM scenarios with and without the support of the AA solutions. Results demonstrated the effectiveness of the proposed pBCI system, since it enabled the AA mostly during the high-demanding conditions (i.e., overload situations) inducing a reduction of the mental workload under which the ATCOs were operating. On the contrary, as desired, the AA was not activated when workload level was under the threshold, to prevent too low demanding conditions that could bring the operator's workload level toward potentially dangerous conditions of underload.

  5. CANDU passive shutdown systems

    Energy Technology Data Exchange (ETDEWEB)

    Hart, R S; Olmstead, R A [AECL CANDU, Sheridan Park Research Community, Mississauga, ON (Canada)

    1996-12-01

    CANDU incorporates two diverse, passive shutdown systems, independent of each other and from the reactor regulating system. Both shutdown systems function in the low pressure, low temperature, moderator which surrounds the fuel channels. The shutdown systems are functionally different, physically separate, and passive since the driving force for SDS1 is gravity and the driving force for SDS2 is stored energy. The physics of the reactor core itself ensures a degree of passive safety in that the relatively long prompt neutron generation time inherent in the design of CANDU reactors tend to retard power excursions and reduces the speed required for shutdown action, even for large postulated reactivity increases. All passive systems include a number of active components or initiators. Hence, an important aspect of passive systems is the inclusion of fail safe (activated by active component failure) operation. The mechanisms that achieve the fail safe action should be passive. Consequently the passive performance of the CANDU shutdown systems extends beyond their basic modes of operation to include fail safe operation based on natural phenomenon or stored energy. For example, loss of power to the SDS1 clutches results in the drop of the shutdown rods by gravity, loss of power or instrument air to the injection valves of SDS2 results in valve opening via spring action, and rigorous self checking of logic, data and timing by the shutdown systems computers assures a fail safe reactor trip through the collapse of a fluctuating magnetic field or the discharge of a capacitor. Event statistics from operating CANDU stations indicate a significant decrease in protection system faults that could lead to loss of production and elimination of protection system faults that could lead to loss of protection. This paper provides a comprehensive description of the passive shutdown systems employed by CANDU. (author). 4 figs, 3 tabs.

  6. Preliminary evaluation, using passive tubes, of carbon monoxide concentrations in outdoor and indoor air at street level shops in Genoa (Italy)

    Science.gov (United States)

    Valerio, Federico; Pala, Mauro; Lazzarotto, Anna; Balducci, Daniele

    Preliminary information on carbon monoxide (CO) concentrations (exposure time: 8 h) both inside and outside 38 randomly selected shops situated on four heavy traffic streets of Genoa was obtained using passive diffusion tubes. Reproducibility and accuracy of this analytical method were tested in real outdoor urban conditions and found within 25%; the detection limit was 1 mgm -3 of CO. The highest mean CO concentrations (15.8 ± 2.2 mgm -3) were found inside shops on Balbi street, a narrow "canyon street". Only in two small shops and two bars (both with many smokers) and in a delicatessen, were indoor CO concentrations significantly higher than outdoor values. The mean outdoor CO concentrations (mgm -3) along the four streets considered (XX Settembre, Balbi, Rolando, Fillak) were 7.4 ± 2.2; 14.5 ± 8.7; 5.8 ± 0.4; 10.5 ± 3.7, respectively. No statistical difference was found, comparing the mean indoor CO concentration with the mean CO outdoor value, measured simultaneously along the sidewalks of each street. CO concentrations in 10 shops without smokers and the nearest outdoor measurements were linearly correlated ( r = 0.99; p statistically significant difference was found comparing indoor CO pollution in shops with smokers (CO: 8.0 ± 5.4) to those without smokers (CO: 7.1 ± 4.6). Forced ventilation, with air intake far from traffic, proved effective in some specific situations in reducing indoor CO concentrations.

  7. Critical evaluation of a new passive exchange-meter for assessing multimedia fate of persistent organic pollutants at the air-soil interface

    International Nuclear Information System (INIS)

    Liu, Xiang; Ming, Li-Li; Nizzetto, Luca; Borgå, Katrine; Larssen, Thorjørn; Zheng, Qian; Li, Jun; Zhang, Gan

    2013-01-01

    A new passive exchange meter (PEM) to measure inter-compartment fluxes of persistent organic pollutants (POPs) at the interface between soil and the atmosphere is described. The PEM uses labeled reference compounds (RC) added in-situ to vegetation litter deployed in open cylinders designed to trap the vertical downward export of the RCs while allowing free exchange of POPs between litter and air. Fluxes of native compounds (bulk deposition, volatilization and downward export) are quantitatively tracked. One scope of the PEM is to investigate the influence of biogeochemical controls on contaminant re-mobilization. The PEM performance was tested in a subtropical forest by comparing measurements under dense canopy and in a canopy gap; conditions in which deposition and turn-over of organic matter (OM) occur at different rates. Significant differences in fate processes were successfully detected. Surprisingly, mobilization by leaching of more hydrophobic compounds was higher under canopy, possibly as a result of canopy mediated enhancement of OM degradation. -- Highlights: •A new tool for measuring multimedia exchange fluxes of POPs is described. •Deposition, volatilization and leaching, to and from soil surface are targeted. •Precision was sufficient to resolve fluxes differing by less than a factor of 2–5. •Gaps in forest canopy enhanced volatilization of POPs. •Higher leaching of heavier POPs from the litter in the understory is associated to rapid organic matter degradation. -- Time integrated multimedia exchange of POPs in vegetation litter is resolved under dynamic conditions of OM ageing

  8. Techniques for active passivation

    Science.gov (United States)

    Roscioli, Joseph R.; Herndon, Scott C.; Nelson, Jr., David D.

    2016-12-20

    In one embodiment, active (continuous or intermittent) passivation may be employed to prevent interaction of sticky molecules with interfaces inside of an instrument (e.g., an infrared absorption spectrometer) and thereby improve response time. A passivation species may be continuously or intermittently applied to an inlet of the instrument while a sample gas stream is being applied. The passivation species may have a highly polar functional group that strongly binds to either water or polar groups of the interfaces, and once bound presents a non-polar group to the gas phase in order to prevent further binding of polar molecules. The instrument may be actively used to detect the sticky molecules while the passivation species is being applied.

  9. Evaluation of Titanium Dioxide as a Binding Phase for the Passive Sampling of Glyphosate and Aminomethyl Phosphonic Acid in an Aquatic Environment.

    Science.gov (United States)

    Fauvelle, Vincent; Nhu-Trang, Tran-Thi; Feret, Thibaut; Madarassou, Karine; Randon, Jérôme; Mazzella, Nicolas

    2015-06-16

    Glyphosate is the most widely used herbicide on a world scale for the last 40 years, for both urban and agricultural uses. Here we describe the first passive sampling method for estimating the concentration of glyphosate and AMPA (aminomethyl phosphonic acid, one of its major degradation products) in surface water. The sampling method is based on a newly developed configuration of the diffusive gradient in thin-film (DGT) technique, which includes a TiO2 binding phase, already in use for a wide range of anions. Glyphosate and AMPA were retained well on a TiO2 binding phase, and elution in a 1 mL of 1 M NaOH led to recoveries greater than 65%. We found no influence of pH or flow velocity on the diffusion coefficients through 0.8 mm polyacrylamide gels, although they did increase with temperature. TiO2 binding gels were able to accumulate up to 1167 ng of P for both glyphosate and AMPA, and linear accumulation was expected over several weeks, depending on environmental conditions. DGT sampling rates were close to 10 mL day(-1) in ultrapure water, while they were less than 1 mL day(-1) in the presence of naturally occurring ions (e.g., copper, iron, calcium, magnesium). These last results highlighted (i) the ability of DGT to measure only the freely dissolved fraction of glyphosate and AMPA in water and (ii) the needs to determine which fraction (total, particulate, dissolved, freely dissolved) is indeed bioactive.

  10. Sources of present Chernobyl-derived caesium concentrations in surface air and deposition samples

    Energy Technology Data Exchange (ETDEWEB)

    Hoetzl, H.; Rosner, G.; Winkler, R. (Gesellschaft fuer Strahlen-und Umweltforschung Munich, Neuherberg (Germany). Forschungszentrum fuer Umwelt und Gesundheit Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany). Inst. fuer Strahlenschutz)

    1992-06-01

    The sources of Chernobyl-derived caesium concentrations in air and deposition samples collected from mid-1986 to end-1990 at Munich- Neuherberg, Germany, were investigated. Local resuspension has been found to be the main source. By comparison with deposition data from other locations it is estimated that within a range from 20 Bq m[sup -2] to 60 kBq m[sup -2] of initially deposited [sup 137]Cs activity [approx]2% is re-deposited by the process of local resuspension in Austria, Germany, Japan and United Kingdom, while significantly higher total resuspension is to be expected for Denmark and Finland. Stratospheric contribution to present concentrations is shown to be negligible. This is confirmed by cross correlation analysis between the time series of [sup 137]Cs in air and precipitation before and after the Chernobyl accident and the respective time series of cosmogenic [sup 7]Be, which is an indicator of stratospheric input. Seasonal variations of caesium concentrations with maxima in winter were observed. (author). 32 refs.; 5 figs.; 1 tab.

  11. Sources of present Chernobyl-derived caesium concentrations in surface air and deposition samples

    International Nuclear Information System (INIS)

    Hoetzl, H.; Rosner, G.; Winkler, R.; Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg

    1992-01-01

    The sources of Chernobyl-derived caesium concentrations in air and deposition samples collected from mid-1986 to end-1990 at Munich- Neuherberg, Germany, were investigated. Local resuspension has been found to be the main source. By comparison with deposition data from other locations it is estimated that within a range from 20 Bq m -2 to 60 kBq m -2 of initially deposited 137 Cs activity ∼2% is re-deposited by the process of local resuspension in Austria, Germany, Japan and United Kingdom, while significantly higher total resuspension is to be expected for Denmark and Finland. Stratospheric contribution to present concentrations is shown to be negligible. This is confirmed by cross correlation analysis between the time series of 137 Cs in air and precipitation before and after the Chernobyl accident and the respective time series of cosmogenic 7 Be, which is an indicator of stratospheric input. Seasonal variations of caesium concentrations with maxima in winter were observed. (author). 32 refs.; 5 figs.; 1 tab

  12. Modelling and Evaluating Air Quality with Fuzzy Logic Algorithm-Ankara-Cebeci Sample

    OpenAIRE

    Atacak, Ismail; Arici, Nursal; Guner, Dilem

    2017-01-01

    Air is one of the most important life sources for all living things. Gases that are present and absent in the composition of clean air also considered as pollutants in the atmosphere. If the pollutants rise above a certain concentration level, air pollution occurs. Air pollution damages all living things, especially human health. Accurate estimation of pollutant concentrations through air pollution modeling has an important effect in reducing the adverse effects of pollution and taking necess...

  13. Air-deployable oil spill sampling devices review phase 2 testing. Volume 1

    International Nuclear Information System (INIS)

    Hawke, L.; Dumouchel, A.; Fingas, M.; Brown, C.E.

    2007-01-01

    SAIC Canada tested air deployable oil sampling devices for the Emergencies Science and Technology Division of Environment Canada in order to determine the applicability and status of these devices. The 3 devices tested were: Canada's SABER (sampling autonomous buoy for evidence recovery), the United States' POPEIE (probe for oil pollution evidence in the environment); and, Sweden's SAR Floatation 2000. They were tested for buoyancy properties, drift behaviour and sampler sorbent pickup ratios. The SAR and SABER both had lesser draft and greater freeboard, while the POPEIE had much greater draft than freeboard. All 3 devices could be used for oil sample collection in that their drift characteristics would allow for the SABER and SAR devices to be placed upwind of the slick while the POPEIE device could be placed downwind of an oil spill. The sorbent testing revealed that Sefar sorbent and Spectra sorbent used in the 3 devices had negative pickup ratios for diesel but performance improved as oil viscosity increased. Both sorbents are inert and capable of collecting oil in sufficient volumes for consistent fingerprinting analysis. 10 refs., 8 tabs., 8 figs

  14. Impact of preferential sampling on exposure prediction and health effect inference in the context of air pollution epidemiology.

    Science.gov (United States)

    Lee, A; Szpiro, A; Kim, S Y; Sheppard, L

    2015-06-01

    Preferential sampling has been defined in the context of geostatistical modeling as the dependence between the sampling locations and the process that describes the spatial structure of the data. It can occur when networks are designed to find high values. For example, in networks based on the U.S. Clean Air Act monitors are sited to determine whether air quality standards are exceeded. We study the impact of the design of monitor networks in the context of air pollution epidemiology studies. The effect of preferential sampling has been illustrated in the literature by highlighting its impact on spatial predictions. In this paper, we use these predictions as input in a second stage analysis, and we assess how they affect health effect inference. Our work is motivated by data from two United States regulatory networks and health data from the Multi-Ethnic Study of Atherosclerosis and Air Pollution. The two networks were designed to monitor air pollution in urban and rural areas respectively, and we found that the health analysis results based on the two networks can lead to different scientific conclusions. We use preferential sampling to gain insight into these differences. We designed a simulation study, and found that the validity and reliability of the health effect estimate can be greatly affected by how we sample the monitor locations. To better understand its effect on second stage inference, we identify two components of preferential sampling that shed light on how preferential sampling alters the properties of the health effect estimate.

  15. Impact of preferential sampling on exposure prediction and health effect inference in the context of air pollution epidemiology

    Science.gov (United States)

    Lee, A.; Szpiro, A.; Kim, S.Y.; Sheppard, L.

    2018-01-01

    Summary Preferential sampling has been defined in the context of geostatistical modeling as the dependence between the sampling locations and the process that describes the spatial structure of the data. It can occur when networks are designed to find high values. For example, in networks based on the U.S. Clean Air Act monitors are sited to determine whether air quality standards are exceeded. We study the impact of the design of monitor networks in the context of air pollution epidemiology studies. The effect of preferential sampling has been illustrated in the literature by highlighting its impact on spatial predictions. In this paper, we use these predictions as input in a second stage analysis, and we assess how they affect health effect inference. Our work is motivated by data from two United States regulatory networks and health data from the Multi-Ethnic Study of Atherosclerosis and Air Pollution. The two networks were designed to monitor air pollution in urban and rural areas respectively, and we found that the health analysis results based on the two networks can lead to different scientific conclusions. We use preferential sampling to gain insight into these differences. We designed a simulation study, and found that the validity and reliability of the health effect estimate can be greatly affected by how we sample the monitor locations. To better understand its effect on second stage inference, we identify two components of preferential sampling that shed light on how preferential sampling alters the properties of the health effect estimate. PMID:29576734

  16. Sampling of power plant stacks for air toxic emissions: Topical report for Phases 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-21

    Under contract with the US Department of Energy (DE-AC22-92PCO0367), Pittsburgh Energy Technology Center, Radian Corporation has conducted a test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPS). Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical charactization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions.

  17. Strategy for Passivating Char Efficiently at the Pilot Scale

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, Timothy C [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-01-18

    Fast pyrolysis is a promising pathway for the commercialization of liquid transportation fuels from biomass. Fast pyrolysis is performed at moderate heat (450-600 degrees Celcius) in an oxygen-deficient environment. One of the products of fast pyrolysis is biochar, which is often used as a heat source or as a soil amendment. Biochar is a partially reacted solid that is created in the production of bio-oil during fast pyrolysis. Biochar produced at these conditions contains significant quantities of carbon that adsorb oxygen when exposed to air. Biochar adsorption of oxygen is an exothermic process that may generate sufficient heat for combustion in ambient air. Biochar is also a self-insulating material which compounds the effects of heat generated internally. These factors lead to safety concerns and material handling difficulties. The Thermochemical Process Development Unit at the National Renewable Energy Laboratory operates a pilot plant that may be configured for fast pyrolysis, gasification, and will be introducing catalytic fast pyrolysis capabilities in 2018. The TCPDU designed and installed a system to introduce oxygen to collected biochar systematically for a controlled passivation. Biochar is collected and cooled in an oxygen deficient environment during fast pyrolysis. Oxygen is then introduced to the biochar on a mass flow basis. A sparger imbedded within the biochar sample near the bottom of the bed flows air diluted with nitrogen into the char bed, and excess gasses are removed from the top of the collection drum, above the char bed. Pressure within the collection drum is measured indicating adequate flow through filters. Sample weight is recorded before and after passivation. During passivation, temperature is measured at 18 points within the char bed. Oxygen content and temperature are measured leaving the char bed. Maximum temperature parameters were established to ensure operator safety during biochar passivation. Extensive passivation data was

  18. GUIDE TO CALCULATING TRANSPORT EFFICIENCY OF AEROSOLS IN OCCUPATIONAL AIR SAMPLING SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Hogue, M.; Hadlock, D.; Thompson, M.; Farfan, E.

    2013-11-12

    This report will present hand calculations for transport efficiency based on aspiration efficiency and particle deposition losses. Because the hand calculations become long and tedious, especially for lognormal distributions of aerosols, an R script (R 2011) will be provided for each element examined. Calculations are provided for the most common elements in a remote air sampling system, including a thin-walled probe in ambient air, straight tubing, bends and a sample housing. One popular alternative approach would be to put such calculations in a spreadsheet, a thorough version of which is shared by Paul Baron via the Aerocalc spreadsheet (Baron 2012). To provide greater transparency and to avoid common spreadsheet vulnerabilities to errors (Burns 2012), this report uses R. The particle size is based on the concept of activity median aerodynamic diameter (AMAD). The AMAD is a particle size in an aerosol where fifty percent of the activity in the aerosol is associated with particles of aerodynamic diameter greater than the AMAD. This concept allows for the simplification of transport efficiency calculations where all particles are treated as spheres with the density of water (1g cm-3). In reality, particle densities depend on the actual material involved. Particle geometries can be very complicated. Dynamic shape factors are provided by Hinds (Hinds 1999). Some example factors are: 1.00 for a sphere, 1.08 for a cube, 1.68 for a long cylinder (10 times as long as it is wide), 1.05 to 1.11 for bituminous coal, 1.57 for sand and 1.88 for talc. Revision 1 is made to correct an error in the original version of this report. The particle distributions are based on activity weighting of particles rather than based on the number of particles of each size. Therefore, the mass correction made in the original version is removed from the text and the calculations. Results affected by the change are updated.

  19. Experiments to Evaluate and Implement Passive Tracer Gas Methods to Measure Ventilation Rates in Homes

    Energy Technology Data Exchange (ETDEWEB)

    Lunden, Melissa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Heredia, Elizabeth [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cohn, Sebastian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Logue, Jennifer [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-10-01

    This report documents experiments performed in three homes to assess the methodology used to determine air exchange rates using passive tracer techniques. The experiments used four different tracer gases emitted simultaneously but implemented with different spatial coverage in the home. Two different tracer gas sampling methods were used. The results characterize the factors of the execution and analysis of the passive tracer technique that affect the uncertainty in the calculated air exchange rates. These factors include uncertainties in tracer gas emission rates, differences in measured concentrations for different tracer gases, temporal and spatial variability of the concentrations, the comparison between different gas sampling methods, and the effect of different ventilation conditions.

  20. Chemosorption sampling and analysis of formaldehyde in air. Influence on recovery during the simultaneous sampling of formaldehyde, phenol, furfural and furfuryl alcohol

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, K.; Hallgren, C.; Levin, J.O.; Nilsson, C.A.

    1981-12-01

    A method based on trapping formaldehyde on a 2,4-dinitrodinitrophenylhydrazine-coated porous polymer (Amberlite XAD-2) was evaluated for air sampling in occupational environments. The aldehyde is converted to its 2,4-dinitrophenylhydrazone on the adsorbent. The influence of some organic compounds which often occur together with formaldehyde-furfural, phenol and furfuryl alcohol--was studied. The results show that the method allows the sampling of formaldehyde in the range 0.01--1.0 mg/m3 of air, based on a 3-1 (15 min) sample and a coating of 1%. Furfural, phenol, and furfuryl alcohol do not interfere and may be conveniently sampled at the same time. Formaldehyde and furfural hydrazones were analyzed by high-performance liquid chromatography, phenol and furfuryl alcohol by gas chromatography.

  1. Sampling problems and the determination of mercury in surface water, seawater, and air

    International Nuclear Information System (INIS)

    Das, H.A.; van der Sloot, H.A.

    1976-01-01

    Analysis of surface water for mercury comprises the determination of both ionic and organically bound mercury in solution and that of the total mercury content of the suspended matter. Eventually, metallic mercury has to be determined too. Requirements for the sampling procedure are given. A method for the routine determination of mercury in surface water and seawater was developed and applied to Dutch surface waters. The total sample volume is 2500 ml. About 500 ml is used for the determination of the content of suspended matter and the total amount of mercury in the water. The sample is filtered through a bed of previously purified active charcoal at a low flow-rate. The main portion ca. 2000 ml) passes a flow-through centrifuge to separate the solid fraction. One liter is used to separate ''inorganic'' mercury by reduction, volatilization in an airstream and adsorption on active charcoal. The other liter is led through a column of active charcoal to collect all mercury. The procedures were checked with 197 Hg radiotracer both as an ion and incorporated in organic compounds. The mercury is determined by thermal neutron activation, followed by volatilization in a tube furnace and adsorption on a fresh carbon bed. The limit of determination is approximately equal to 1 ng 1 -1 . The rate of desorption from and adsorption on suspended material has been measured as a function of a pH of the solution for Hg +2 and various other ions. It can be concluded that only the procedure mentioned above does not disturb the equilibrium. The separation of mercury from air is obtained by suction of 1 m 3 through a 0.22 μm filter and a charcoal bed. The determination is then performed as in the case of the water samples

  2. Passive vapor extraction feasibility study

    International Nuclear Information System (INIS)

    Rohay, V.J.

    1994-01-01

    Demonstration of a passive vapor extraction remediation system is planned for sites in the 200 West Area used in the past for the disposal of waste liquids containing carbon tetrachloride. The passive vapor extraction units will consist of a 4-in.-diameter pipe, a check valve, a canister filled with granular activated carbon, and a wind turbine. The check valve will prevent inflow of air that otherwise would dilute the soil gas and make its subsequent extraction less efficient. The granular activated carbon is used to adsorb the carbon tetrachloride from the air. The wind turbine enhances extraction rates on windy days. Passive vapor extraction units will be designed and operated to meet all applicable or relevant and appropriate requirements. Based on a cost analysis, passive vapor extraction was found to be a cost-effective method for remediation of soils containing lower concentrations of volatile contaminants. Passive vapor extraction used on wells that average 10-stdft 3 /min air flow rates was found to be more cost effective than active vapor extraction for concentrations below 500 parts per million by volume (ppm) of carbon tetrachloride. For wells that average 5-stdft 3 /min air flow rates, passive vapor extraction is more cost effective below 100 ppm

  3. Application of the CaF2(Eu) scintillator to 85Kr monitoring in atmospheric air samples

    International Nuclear Information System (INIS)

    Wilhelmova, Ludmila; Dvorak, Zdenek; Tomasek, Milan; Stukheil, Karel

    1986-01-01

    A detection system with a CaF 2 (Eu) scintillator has been developed for monitoring β-radiation of 85 Kr in atmospheric air samples. The geometry of the detector chamber was optimized to achieve maximum detection efficiency. The design of the detector is described and values of the detection efficiency are presented for various compositions and pressures of the gaseous samples. The conditions for calibration of the detector used for monitoring of 85 Kr in enriched air samples have been established. (author)

  4. Air sampling to assess potential generation of aerosolized viable bacteria during flow cytometric analysis of unfixed bacterial suspensions

    Science.gov (United States)

    Carson, Christine F; Inglis, Timothy JJ

    2018-01-01

    This study investigated aerosolized viable bacteria in a university research laboratory during operation of an acoustic-assisted flow cytometer for antimicrobial susceptibility testing by sampling room air before, during and after flow cytometer use. The aim was to assess the risk associated with use of an acoustic-assisted flow cytometer analyzing unfixed bacterial suspensions. Air sampling in a nearby clinical laboratory was conducted during the same period to provide context for the existing background of microorganisms that would be detected in the air. The three species of bacteria undergoing analysis by flow cytometer in the research laboratory were Klebsiella pneumoniae, Burkholderia thailandensis and Streptococcus pneumoniae. None of these was detected from multiple 1000 L air samples acquired in the research laboratory environment. The main cultured bacteria in both locations were skin commensal and environmental bacteria, presumed to have been disturbed or dispersed in laboratory air by personnel movements during routine laboratory activities. The concentrations of bacteria detected in research laboratory air samples were reduced after interventional cleaning measures were introduced and were lower than those in the diagnostic clinical microbiology laboratory. We conclude that our flow cytometric analyses of unfixed suspensions of K. pneumoniae, B. thailandensis and S. pneumoniae do not pose a risk to cytometer operators or other personnel in the laboratory but caution against extrapolation of our results to other bacteria and/or different flow cytometric experimental procedures. PMID:29608197

  5. Determination of biomass burning tracers in air samples by GC/MS

    Directory of Open Access Journals (Sweden)

    Janoszka Katarzyna

    2018-01-01

    Full Text Available Levoglucosan (LG as a main cellulose burning product at 300°C is a biomass burning tracer. LG characterize by relatively high molar mass and it is sorbed by particulate matter. In the study of air pollution monitoring LG is mainly analyzed in particulate matter, PM1 and PM2,5. The tracer create relatively high O-H…O bond and weaker C-H…O bond. Due to the hydrogen bond, LG dissolves very well in water. Analytical procedure of LG determination include: extraction, derivatization and analysis by gas chromatography coupled with mass spectrometry detector. In water samples levoglucosan is determined by liquid chromatography. The paper presents a methodology for particulate matter samples determination their analysis by gas chromatography coupled with a mass spectrometry detector. Determination of LG content in particulate matter was performed according to an analytical method based on simultaneous pyridine extraction and derivatization using N,O-bis (trimethylsilyl trifluoroacetamide and trimethylchlorosilane mixture (BSTFA: TMCS, 99: 1.

  6. Determination of biomass burning tracers in air samples by GC/MS

    Science.gov (United States)

    Janoszka, Katarzyna

    2018-01-01

    Levoglucosan (LG) as a main cellulose burning product at 300°C is a biomass burning tracer. LG characterize by relatively high molar mass and it is sorbed by particulate matter. In the study of air pollution monitoring LG is mainly analyzed in particulate matter, PM1 and PM2,5. The tracer create relatively high O-H…O bond and weaker C-H…O bond. Due to the hydrogen bond, LG dissolves very well in water. Analytical procedure of LG determination include: extraction, derivatization and analysis by gas chromatography coupled with mass spectrometry detector. In water samples levoglucosan is determined by liquid chromatography. The paper presents a methodology for particulate matter samples determination their analysis by gas chromatography coupled with a mass spectrometry detector. Determination of LG content in particulate matter was performed according to an analytical method based on simultaneous pyridine extraction and derivatization using N,O-bis (trimethylsilyl) trifluoroacetamide and trimethylchlorosilane mixture (BSTFA: TMCS, 99: 1).

  7. Remote control air sampling and fast chemical analysis of the composition

    Energy Technology Data Exchange (ETDEWEB)

    Kukuczka, A; Golisz, T

    1981-01-01

    In 1979 the Central mine rescue station in Bytom (Poland) developed and introduced into use a new method of remote control air and gas (from fires) sampling and swift chemical analysis of the samples' composition. The device in this method includes: a probe (situated beyond the fire detector directly in the control zone), thick-walled elastic hose, direr, piston pump, rotameter, chromatograph and minicomputer. The basic technical data included in the set: the capacity of the pump 8 1/min, 2.5 kg mass. run on 12 V current (built at the Main Mining Affairs Inst. in Poland); the chromatograph is VARIAN 1420-10 (USA produced),the working gas is helium (balloon volume 40 1), feed--alternating 220V, capacity--1.5 kW, time for measuring gas from fires-- 15 to 20 min (as apposed to the 1.5h spent before when the SRC device was being used) at an accuracy of /sup + -/ 0.05% (volume); the chromatograph works with a mini-computer (model CDS-111C) with a 20 kg mass.and a size of 16 x 46 x 56 cm. As tests in Moszczenica coal mines, where a fire in 504/2 occurred, showed (the chromatograph was located 750m from the probe for burning gases), the method proved to be a good one although the VARIAN 1420-10 was insufficiently reliable and the VARIAN-1400-AEROGRAF proved to be better.

  8. Forecasting Urban Air Quality via a Back-Propagation Neural Network and a Selection Sample Rule

    Directory of Open Access Journals (Sweden)

    Yonghong Liu

    2015-07-01

    Full Text Available In this paper, based on a sample selection rule and a Back Propagation (BP neural network, a new model of forecasting daily SO2, NO2, and PM10 concentration in seven sites of Guangzhou was developed using data from January 2006 to April 2012. A meteorological similarity principle was applied in the development of the sample selection rule. The key meteorological factors influencing SO2, NO2, and PM10 daily concentrations as well as weight matrices and threshold matrices were determined. A basic model was then developed based on the improved BP neural network. Improving the basic model, identification of the factor variation consistency was added in the rule, and seven sets of sensitivity experiments in one of the seven sites were conducted to obtain the selected model. A comparison of the basic model from May 2011 to April 2012 in one site showed that the selected model for PM10 displayed better forecasting performance, with Mean Absolute Percentage Error (MAPE values decreasing by 4% and R2 values increasing from 0.53 to 0.68. Evaluations conducted at the six other sites revealed a similar performance. On the whole, the analysis showed that the models presented here could provide local authorities with reliable and precise predictions and alarms about air quality if used at an operational scale.

  9. Sampling of power plant stacks for air toxic emissions: Final report for Phases 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-28

    A test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPs) was conducted . Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical characterization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions. Field testing was conducted in two phases. The Phase I field program was performed over the period of August 24 through September 20, 1992, at the Tennessee Valley Authority Widows Creek Unit 8 Power Station, located near Stevenson (Jackson County), Alabama, on the Tennessee River. Sampling activities for Phase II were conducted from September 11 through October 14, 1993. Widows Creek Unit 8 is a 575-megawatt plant that uses bituminous coal averaging 3.7% sulfur and 13% ash. Downstream of the boiler, a venture wet scrubbing system is used for control of both sulfur dioxide and particulate emissions. There is no electrostatic precipitator (ESP) in this system. This system is atypical and represents only about 5% of the US utility industry. However, this site was chosen for this study because of the lack of information available for this particulate emission control system.

  10. Occurrence and quantitative microbial risk assessment of Cryptosporidium and Giardia in soil and air samples

    Directory of Open Access Journals (Sweden)

    Ana Paola Balderrama-Carmona

    2014-09-01

    Conclusions: Soil and air inhalation and/or ingestion are important vehicles for these parasites. To our knowledge, the results obtained in the present study represent the first QMRAs for cryptosporidiosis and giardiasis due to soil and air inhalation/ingestion in Mexico. In addition, this is the first evidence of the microbial air quality around these parasites in rural zones.

  11. Early Detection of Foot-And-Mouth Disease Virus from Infected Cattle Using A Dry Filter Air Sampling System.

    Science.gov (United States)

    Pacheco, J M; Brito, B; Hartwig, E; Smoliga, G R; Perez, A; Arzt, J; Rodriguez, L L

    2017-04-01

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to the aerogenous nature of the virus. In the current study, air from rooms housing individual (n = 17) or two groups (n = 4) of cattle experimentally infected with FDMV A24 Cruzeiro of different virulence levels was sampled to assess the feasibility of applying air sampling as a non-invasive, screening tool to identify sources of FMDV infection. Detection of FMDV RNA in air was compared with first detection of clinical signs and FMDV RNA levels in serum and oral fluid. FMDV RNA was detected in room air samples 1-3 days prior (seven animals) or on the same day (four animals) as the appearance of clinical signs in 11 of 12 individually housed cattle. Only in one case clinical signs preceded detection in air samples by one day. Overall, viral RNA in oral fluid or serum preceded detection in air samples by 1-2 days. Six individually housed animals inoculated with attenuated strains did not show clinical signs, but virus was detected in air in one of these cases 3 days prior to first detection in oral fluid. In groups of four cattle housed together, air detection always preceded appearance of clinical signs by 1-2 days and coincided more often with viral shedding in oral fluid than virus in blood. These data confirm that air sampling is an effective non-invasive screening method for detecting FMDV infection in confined to enclosed spaces (e.g. auction barns, milking parlours). This technology could be a useful tool as part of a surveillance strategy during FMD prevention, control or eradication efforts. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  12. Potential contamination of shipboard air samples by diffusive emissions of PCBs and other organic pollutants: implications and solutions.

    Science.gov (United States)

    Lohmann, Rainer; Jaward, Foday M; Durham, Louise; Barber, Jonathan L; Ockenden, Wendy; Jones, Kevin C; Bruhn, Regina; Lakaschus, Soenke; Dachs, Jordi; Booij, Kees

    2004-07-15

    Air samples were taken onboard the RRS Bransfield on an Atlantic cruise from the United Kingdom to Halley, Antarctica, from October to December 1998, with the aim of establishing PCB oceanic background air concentrations and assessing their latitudinal distribution. Great care was taken to minimize pre- and post-collection contamination of the samples, which was validated through stringent QA/QC procedures. However, there is evidence that onboard contamination of the air samples occurred,following insidious, diffusive emissions on the ship. Other data (for PCBs and other persistent organic pollutants (POPs)) and examples of shipboard contamination are presented. The implications of these findings for past and future studies of global POPs distribution are discussed. Recommendations are made to help critically appraise and minimize the problems of insidious/diffusive shipboard contamination.

  13. Detection of Campylobacter Bacteria in Air Samples for Continuous Real-Time Monitoring of Campylobacter Colonization in Broiler Flocks

    DEFF Research Database (Denmark)

    Olsen, Katja Nyholm; Lund, Marianne; Skov, J.

    2009-01-01

    Improved monitoring tools are important for the control of Campylobacter bacteria in broiler production. In this study, we compare the sensitivities of detection of Campylobacter by PCR with feces, dust, and air samples during the lifetimes of broilers in two poultry houses and conclude that the ......Improved monitoring tools are important for the control of Campylobacter bacteria in broiler production. In this study, we compare the sensitivities of detection of Campylobacter by PCR with feces, dust, and air samples during the lifetimes of broilers in two poultry houses and conclude...... that the sensitivity of detection of Campylobacter in air is comparable to that in other sample materials. Profiling of airborne particles in six poultry houses revealed that the aerodynamic conditions were dependent on the age of the chickens and very comparable among different poultry houses, with low proportions...

  14. Day and night variation in chemical composition and toxicological responses of size segregated urban air PM samples in a high air pollution situation

    Science.gov (United States)

    Jalava, P. I.; Wang, Q.; Kuuspalo, K.; Ruusunen, J.; Hao, L.; Fang, D.; Väisänen, O.; Ruuskanen, A.; Sippula, O.; Happo, M. S.; Uski, O.; Kasurinen, S.; Torvela, T.; Koponen, H.; Lehtinen, K. E. J.; Komppula, M.; Gu, C.; Jokiniemi, J.; Hirvonen, M.-R.

    2015-11-01

    Urban air particulate pollution is a known cause for adverse human health effects worldwide. China has encountered air quality problems in recent years due to rapid industrialization. Toxicological effects induced by particulate air pollution vary with particle sizes and season. However, it is not known how distinctively different photochemical activity and different emission sources during the day and the night affect the chemical composition of the PM size ranges and subsequently how it is reflected to the toxicological properties of the PM exposures. The particulate matter (PM) samples were collected in four different size ranges (PM10-2.5; PM2.5-1; PM1-0.2 and PM0.2) with a high volume cascade impactor. The PM samples were extracted with methanol, dried and thereafter used in the chemical and toxicological analyses. RAW264.7 macrophages were exposed to the particulate samples in four different doses for 24 h. Cytotoxicity, inflammatory parameters, cell cycle and genotoxicity were measured after exposure of the cells to particulate samples. Particles were characterized for their chemical composition, including ions, element and PAH compounds, and transmission electron microscopy (TEM) was used to take images of the PM samples. Chemical composition and the induced toxicological responses of the size segregated PM samples showed considerable size dependent differences as well as day to night variation. The PM10-2.5 and the PM0.2 samples had the highest inflammatory potency among the size ranges. Instead, almost all the PM samples were equally cytotoxic and only minor differences were seen in genotoxicity and cell cycle effects. Overall, the PM0.2 samples had the highest toxic potential among the different size ranges in many parameters. PAH compounds in the samples and were generally more abundant during the night than the day, indicating possible photo-oxidation of the PAH compounds due to solar radiation. This was reflected to different toxicity in the PM

  15. Comparison of halocarbon measurements in an atmospheric dry whole air sample.

    Science.gov (United States)

    Rhoderick, George C; Hall, Bradley D; Harth, Christina M; Kim, Jin Seog; Lee, Jeongsoon; Montzka, Stephen A; Mühle, Jens; Reimann, Stefan; Vollmer, Martin K; Weiss, Ray F

    The growing awareness of climate change/global warming, and continuing concerns regarding stratospheric ozone depletion, will require continued measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track atmospheric mole fractions and assess the impact of policy on emission rates, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. Precise measurements of these species aid in determining small changes in their atmospheric abundance. A common source of standards/scales and/or well-documented agreement of different scales used to calibrate the measurement instrumentation are key to understanding many sets of data reported by researchers. This report describes the results of a comparison study among National Metrology Institutes and atmospheric research laboratories for the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC-12), trichlorofluoromethane (CFC-11), and 1,1,2-trichlorotrifluoroethane (CFC-113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC-22) and 1-chloro-1,1-difluoroethane (HCFC-142b); and the hydrofluorocarbon (HFC) 1,1,1,2-tetrafluoroethane (HFC-134a), all in a dried whole air sample. The objective of this study is to compare calibration standards/scales and the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. The results of this study show agreement among four independent calibration scales to better than 2.5% in almost all cases, with many of the reported agreements being better than 1.0%.

  16. Comparison of halocarbon measurements in an atmospheric dry whole air sample

    Directory of Open Access Journals (Sweden)

    George C. Rhoderick

    2015-11-01

    Full Text Available Abstract The growing awareness of climate change/global warming, and continuing concerns regarding stratospheric ozone depletion, will require continued measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track atmospheric mole fractions and assess the impact of policy on emission rates, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. Precise measurements of these species aid in determining small changes in their atmospheric abundance. A common source of standards/scales and/or well-documented agreement of different scales used to calibrate the measurement instrumentation are key to understanding many sets of data reported by researchers. This report describes the results of a comparison study among National Metrology Institutes and atmospheric research laboratories for the chlorofluorocarbons (CFCs dichlorodifluoromethane (CFC-12, trichlorofluoromethane (CFC-11, and 1,1,2-trichlorotrifluoroethane (CFC-113; the hydrochlorofluorocarbons (HCFCs chlorodifluoromethane (HCFC-22 and 1-chloro-1,1-difluoroethane (HCFC-142b; and the hydrofluorocarbon (HFC 1,1,1,2-tetrafluoroethane (HFC-134a, all in a dried whole air sample. The objective of this study is to compare calibration standards/scales and the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. The results of this study show agreement among four independent calibration scales to better than 2.5% in almost all cases, with many of the reported agreements being better than 1.0%.

  17. Comparison of halocarbon measurements in an atmospheric dry whole air sample

    Science.gov (United States)

    Hall, Bradley D.; Harth, Christina M.; Kim, Jin Seog; Lee, Jeongsoon; Montzka, Stephen A.; Mühle, Jens; Reimann, Stefan; Vollmer, Martin K.; Weiss, Ray F.

    2015-01-01

    The growing awareness of climate change/global warming, and continuing concerns regarding stratospheric ozone depletion, will require continued measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track atmospheric mole fractions and assess the impact of policy on emission rates, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. Precise measurements of these species aid in determining small changes in their atmospheric abundance. A common source of standards/scales and/or well-documented agreement of different scales used to calibrate the measurement instrumentation are key to understanding many sets of data reported by researchers. This report describes the results of a comparison study among National Metrology Institutes and atmospheric research laboratories for the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC-12), trichlorofluoromethane (CFC-11), and 1,1,2-trichlorotrifluoroethane (CFC-113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC-22) and 1-chloro-1,1-difluoroethane (HCFC-142b); and the hydrofluorocarbon (HFC) 1,1,1,2-tetrafluoroethane (HFC-134a), all in a dried whole air sample. The objective of this study is to compare calibration standards/scales and the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. The results of this study show agreement among four independent calibration scales to better than 2.5% in almost all cases, with many of the reported agreements being better than 1.0%. PMID:26753167

  18. Mathematical solutions to problems in radiological protection involving air sampling and biokinetic modelling

    International Nuclear Information System (INIS)

    Birchall, A.

    1989-04-01

    Intakes of radionuclides are estimated with the personal air sampler (PAS) and by biological monitoring techniques: in the case of plutonium, there are problems with both methods. The statistical variation in activity collected when sampling radioactive aerosols with low number concentrations was investigated. It was shown that the PAS is barely adequate for monitoring plutonium at annual limit of intake (ALI) levels in typical workplace conditions. Two algorithms were developed, enabling non-recycling and recycling compartmental models to be solved. Their accuracy and speed were investigated, and methods of dealing with partitioning, continuous intake, and radioactive progeny were discussed. Analytical, rather than numerical, methods were used. These are faster, and thus ideally suited for implementation on microcomputers. The algorithms enable non-specialists to solve quickly and easily any first order compartmental model, including all the ICRP metabolic models. Non-recycling models with up to 50 compartments can be solved in seconds: recycling models take a little longer. A biokinetic model for plutonium in man following systemic uptake was developed. The proposed ICRP lung model (1989) was represented by a first order compartmental model. These two models were combined, and the recycling algorithm was used to calculate urinary and faecal excretion of plutonium following acute or chronic intake by inhalation. The results indicate much lower urinary excretion than predicted by ICRP Publication 54. (author)

  19. Air and Surface Sampling Method for Assessing Exposures to Quaternary Ammonium Compounds Using Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    LeBouf, Ryan F; Virji, Mohammed Abbas; Ranpara, Anand; Stefaniak, Aleksandr B

    2017-07-01

    This method was designed for sampling select quaternary ammonium (quat) compounds in air or on surfaces followed by analysis using ultraperformance liquid chromatography tandem mass spectrometry. Target quats were benzethonium chloride, didecyldimethylammonium bromide, benzyldimethyldodecylammonium chloride, benzyldimethyltetradecylammonium chloride, and benzyldimethylhexadecylammonium chloride. For air sampling, polytetrafluoroethylene (PTFE) filters are recommended for 15-min to 24-hour sampling. For surface sampling, Pro-wipe® 880 (PW) media was chosen. Samples were extracted in 60:40 acetonitrile:0.1% formic acid for 1 hour on an orbital shaker. Method detection limits range from 0.3 to 2 ng/ml depending on media and analyte. Matrix effects of media are minimized through the use of multiple reaction monitoring versus selected ion recording. Upper confidence limits on accuracy meet the National Institute for Occupational Safety and Health 25% criterion for PTFE and PW media for all analytes. Using PTFE and PW analyzed with multiple reaction monitoring, the method quantifies levels among the different quats compounds with high precision (detection limits to capture quats on air sampling filters with only a 15-min sample duration with a maximum assessed storage time of 103 days before sample extraction. This method will support future exposure assessment and quantitative epidemiologic studies to explore exposure-response relationships and establish levels of quats exposures associated with adverse health effects. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  20. An analytical method for trifluoroacetic Acid in water and air samples using headspace gas chromatographic determination of the methyl ester.

    Science.gov (United States)

    Zehavi, D; Seiber, J N

    1996-10-01

    An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA.

  1. Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings.

    Science.gov (United States)

    Normand, Anne-Cécile; Ranque, Stéphane; Cassagne, Carole; Gaudart, Jean; Sallah, Kankoé; Charpin, Denis-André; Piarroux, Renaud

    2016-03-01

    Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments. © The Author 2015

  2. Hood River Passive House

    Energy Technology Data Exchange (ETDEWEB)

    Hales, David [BA-PIRC, Spokane, WA (United States)

    2014-01-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

  3. Estimating Sampling Biases and Measurement Uncertainties of AIRS-AMSU-A Temperature and Water Vapor Observations Using MERRA Reanalysis

    Science.gov (United States)

    Hearty, Thomas J.; Savtchenko, Andrey K.; Tian, Baijun; Fetzer, Eric; Yung, Yuk L.; Theobald, Michael; Vollmer, Bruce; Fishbein, Evan; Won, Young-In

    2014-01-01

    We use MERRA (Modern Era Retrospective-Analysis for Research Applications) temperature and water vapor data to estimate the sampling biases of climatologies derived from the AIRS/AMSU-A (Atmospheric Infrared Sounder/Advanced Microwave Sounding Unit-A) suite of instruments. We separate the total sampling bias into temporal and instrumental components. The temporal component is caused by the AIRS/AMSU-A orbit and swath that are not able to sample all of time and space. The instrumental component is caused by scenes that prevent successful retrievals. The temporal sampling biases are generally smaller than the instrumental sampling biases except in regions with large diurnal variations, such as the boundary layer, where the temporal sampling biases of temperature can be +/- 2 K and water vapor can be 10% wet. The instrumental sampling biases are the main contributor to the total sampling biases and are mainly caused by clouds. They are up to 2 K cold and greater than 30% dry over mid-latitude storm tracks and tropical deep convective cloudy regions and up to 20% wet over stratus regions. However, other factors such as surface emissivity and temperature can also influence the instrumental sampling bias over deserts where the biases can be up to 1 K cold and 10% wet. Some instrumental sampling biases can vary seasonally and/or diurnally. We also estimate the combined measurement uncertainties of temperature and water vapor from AIRS/AMSU-A and MERRA by comparing similarly sampled climatologies from both data sets. The measurement differences are often larger than the sampling biases and have longitudinal variations.

  4. The effects of ambient conditions on the passive dust sampler when used in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Hemingway, M.; Thorpe, A.

    1998-09-01

    A previous feasibility study of the Health and Safety Laboratory (HSL) electret-based passive dust sampler carried out during site sampling in coal mines showed that the measurements made with the passive sampler and those made with the MRE sampler correlated well in each of two mines, but the ratios of samples obtained with the passive sampler and the MRE sampler in the two mines were different. This means the passive sampler would need a separate calibration for each coal mine in which it was used. Laboratory tests and further underground trials were carried out to quantify the possible effects of temperature and humidity on ratios. The passive dust samplers used at Maltby Colliery in the UK were found to pass the acceptance criteria according to the CEN standard for the assessment of the performance of instruments for the measurement of airborne particles, provided that samplers exposed when coal was not being cut were not included in the analysis. Temperature and relative humidity slightly affected the behaviour of the passive sampler during laboratory trials and relative humidity was found to possibly affect the behaviour during field trials. Ventilation rates had no effect on the passive sampler behaviour but the orientation of the passive dust sampler with respect to air flow affected the behaviour during laboratory trials. Further work is needed to quantify effects. 7 refs., 14 figs., 3 tabs.

  5. The sampling of hydrogen fluoride in air with impregnated filter paper

    NARCIS (Netherlands)

    Huygen, C.

    1963-01-01

    A method isproposed for the quantitative collection of hydrogen fluoride in air by drawing a known quantity of the air through filter paper impregnated with solutions of potassium hydroxide and glycerol or triethanolamine. Somu possibilities and limitations of the method are discussed.

  6. Determination of gamma emitting radionuclides in environmental air and precipitation samples with a Ge(Li) detector

    International Nuclear Information System (INIS)

    Hoetzl, H.; Rosner, G.; Winkler, R.; Sansoni, B.

    1977-01-01

    The concentrations of the radionuclides 7 Be, 54 Mn, 95 Zr, 95 Nb, 103 Ru, 106 Ru, 125 Sb, 137 Cs, 140 Ba/ 140 La, 141 Ce and 144 Ce in ground level air and of 7 Be, 95 Zr, 137 Cs and 144 Ce in precipitation were determined since 1970 and 1971 respectively at Neuherberg, 10 km north of Munich, by gamma spectrometry using a 60 cm 3 Ge(Li) detector. Dust samples were collected twice a month 1 m above ground from about 40,000 m 3 of air on 46 cm x 28 cm microsorbane filters and pressed to small cylinders of 35 cm 3 in size. Sensitivity of the procedure is of the order of 1 fCi/m 3 for air and of 10 pCi/m 2 per month for precipitation samples at a counting time of 1500 min. (author)

  7. The Comparative Study Of Saprophytic Fungi In Air Canal, Air, Hospital Instruments And Clinical Samples From Patients With Bone Marrow Transplantation

    Directory of Open Access Journals (Sweden)

    Hashemi S J

    2004-08-01

    Full Text Available Background: Bone Marrow Transplantation is one of the most important therapeutic methods in much malignant and nonmalignant disease. Patients with Bone Marrow Transplantation (BMT following radiotherapy and chemotherapy will suffer from immuno-suppression. Therefore they are susceptible to get saprophytic fungi infection that sometimes are killer. Materials and Methods: The purpose of this cross-sectional survey is isolation of saprophytic fungi from patients with BMT and wards space and instruments. Therefore sampling from ventilator system (HEPA filter and common filter, air canal, air, hospital instruments and clinical samples (nasal discharge, sputum, urine were done and cultured in sabouro dextrose agar with choloramphenicol (SC. In assessing total frequency from 4838 plates of wards space and instruments, 985 fungi colonies includes 21 genus were isolated. Results and Conclusion: Most fungi colonies present were Penicillium , Aspergillus and Cladosporium and low present were Trichoderma ,Stereptomyses, Chrysosporium, Rhizopus.

  8. Description and evaluation of a peracetic acid air sampling and analysis method.

    Science.gov (United States)

    Nordling, John; Kinsky, Owen R; Osorio, Magdalena; Pechacek, Nathan

    2017-12-01

    Peracetic acid (PAA) is a corrosive chemical with a pungent odor, which is extensively used in occupational settings and causes various health hazards in exposed workers. Currently, there is no US government agency recommended method that could be applied universally for the sampling and analysis of PAA. Legacy methods for determining airborne PAA vapor levels frequently suffered from cross-reactivity with other chemicals, particularly hydrogen peroxide (H 2 O 2 ). Therefore, to remove the confounding factor of cross-reactivity, a new viable, sensitive method was developed for assessment of PAA exposure levels, based on the differential reaction kinetics of PAA with methyl p-tolylsulfide (MTS), relative to H 2 O 2 , to preferentially derive methyl p-tolysulfoxide (MTSO). By quantifying MTSO concentration produced in the liquid capture solution from an air sampler, using an internal standard, and utilizing the reaction stoichiometry of PAA and MTS, the original airborne concentration of PAA is determined. After refining this liquid trap high-performance liquid chromatography (HPLC) method in the laboratory, it was tested in five workplace settings where PAA products were used. PAA levels ranged from the detection limit of 0.013 parts per million (ppm) to 0.4 ppm. The results indicate a viable and potentially dependable method to assess the concentrations of PAA vapors under occupational exposure scenarios, though only a small number of field measurements were taken while field testing this method. However, the low limit of detection and precision offered by this method makes it a strong candidate for further testing and validation to expand the uses of this liquid trap HPLC method.

  9. Free radicals of an aromatic nature in air samples from iron foundries

    Energy Technology Data Exchange (ETDEWEB)

    Westerberg, L M

    1982-01-01

    Free radicals of relatively long life were identified as spin adducts of phenyl-N-tert-butylnitrone. Pyrolysis studies showed the radicals were oxy-radicals. The hyperfine splitting constants of spin adducts of radicals from the pyrolysis in air of benzo(a)pyrene, coal tar pitch, and moulding sand containing hard coal dust were the same as those of the radicals found in foundry air. Since these radicals can bind to DNA, they must be considered when estimating the hazardous effects of polluted air.

  10. An indoor air quality-pharmacokinetic simulation of passive inhalation of marijuana smoke and the resultant buildup of 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid in urine.

    Science.gov (United States)

    Giardino, N J

    1997-03-01

    In military courts of law, the good soldier defense is often used by the defendant to explain the presence of 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid in urine (hereafter referred to as THCA) above the Department of Defense (DOD) established limit of 15 ng/mL. The defense will contend the defendant unwittingly breathed side-stream marijuana smoke, thus resulting in the presence of THCA in the defendant's urine. The purpose of this work was to link an indoor air quality model (IAQ) with a pharmacokinetic (PK) model to predict a passive marijuana smoker's resultant concentration of the major urinary metabolite THCA.

  11. [Measurement of Chemical Compounds in Indoor and Outdoor Air in Chiba City Using Diffusive Sampling Devices].

    Science.gov (United States)

    Sakamoto, Hironari; Uchiyama, Shigehisa; Kihara, Akiko; Tsutake, Toyoshige; Bekki, Kanae; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki

    2015-01-01

    Indoor air quality (IAQ) is a major concern, because people on average spend the vast majority of their time indoors and they are repeatedly exposed to indoor air pollutants. In this study, to assess indoor air quality in Chiba City, gaseous chemical compounds were surveyed using four types of diffusive sampler. Gaseous chemical compounds such as carbonyls, volatile organic compounds (VOC), acid gases, basic gases, and ozone were measured in indoor and outdoor air of 50 houses throughout Chiba City in winter and summer. Four types of diffusive sampler were used in this study: DSD-BPE/DNPH packed with 2,4-dinitrophenyl hydrazine and trans-1,2-bis(2-pyridyl)ethylene-coated silica for ozone and carbonyls; VOC-SD packed with Carboxen 564 particles for volatile organic compounds; DSD-TEA packed with triethanolamine-impregnated silica for acid gases; and DSD-NH3 packed with phosphoric acid-impregnated silica for basic gases. Almost all compounds in indoor air were detected at higher concentrations in summer than in winter. However, the nitrogen dioxide concentration in indoor air particularly increased only in winter, which well correlated with the formic acid concentration (correlation coefficient=0.974). The compound with the highest concentrations in indoor air was p-dichlorobenzene, with recorded levels of 13,000 μg m(-3) in summer and 1,100 μg m(-3) in winter in indoor air. p-Dichlorobenzene in summer and nitrogen dioxide in winter are detected at markedly high concentrations. Pollution control and continuous monitoring of IAQ are indispensable for human health.

  12. Scheduling whole-air samples above the Trade Wind Inversion from SUAS using real-time sensors

    Science.gov (United States)

    Freer, J. E.; Greatwood, C.; Thomas, R.; Richardson, T.; Brownlow, R.; Lowry, D.; MacKenzie, A. R.; Nisbet, E. G.

    2015-12-01

    Small Unmanned Air Systems (SUAS) are increasingly being used in science applications for a range of applications. Here we explore their use to schedule the sampling of air masses up to 2.5km above ground using computer controlled bespoked Octocopter platforms. Whole-air sampling is targeted above, within and below the Trade Wind Inversion (TWI). On-board sensors profiled the TWI characteristics in real time on ascent and, hence, guided the altitudes at which samples were taken on descent. The science driver for this research is investigation of the Southern Methane Anomaly and, more broadly, the hemispheric-scale transport of long-lived atmospheric tracers in the remote troposphere. Here we focus on the practical application of SUAS for this purpose. Highlighting the need for mission planning, computer control, onboard sensors and logistics in deploying such technologies for out of line-of-sight applications. We show how such a platform can be deployed successfully, resulting in some 60 sampling flights within a 10 day period. Challenges remain regarding the deployment of such platforms routinely and cost-effectively, particularly regarding training and support. We present some initial results from the methane sampling and its implication for exploring and understanding the Southern Methane Anomaly.

  13. Early detection of sugar beet pathogen Ramularia beticola in leaf and air samples using qPCR

    DEFF Research Database (Denmark)

    Wieczorek, Thies Marten; Jørgensen, Lise Nistrup; Hansen, Anne Lisbet

    2014-01-01

    A quantitative PCR method (qPCR) was developed for the detection and quantification of Ramularia beticola causing Ramularia leaf spot in sugar beet. R. beticola specific primers were designed based on the internal transcribed spacer region 2 (ITS2). The assay was applied on DNA extracted from...... spores trapped on tape from Burkard spore traps placed in an artificially inoculated sugar beet field trial and in two sugar beet fields with natural infections. R. beticola DNA was detected at variable amounts in the air samples 14 to 16 days prior to first visible symptoms. R. beticola DNA was detected...... in air samples from fields with natural infection at significant and increasing levels from development of the first symptoms, indicating that spore production within the crop plays a major role in the epidemic development of the disease. Sugar beet leaves sampled from the inoculated field trial were...

  14. Passive cooling containment study

    International Nuclear Information System (INIS)

    Shin, J.J.; Iotti, R.C.; Wright, R.F.

    1993-01-01

    Pressure and temperature transients of nuclear reactor containment following postulated loss of coolant accident with a coincident station blackout due to total loss of all alternating current power are studied analytically and experimentally for the full scale NPR (New Production Reactor). All the reactor and containment cooling under this condition would rely on the passive cooling system which removes reactor decay heat and provides emergency core and containment cooling. Containment passive cooling for this study takes place in the annulus between containment steel shell and concrete shield building by natural convection air flow and thermal radiation. Various heat transfer coefficients inside annular air space were investigated by running the modified CONTEMPT code CONTEMPT-NPR. In order to verify proper heat transfer coefficient, temperature, heat flux, and velocity profiles were measured inside annular air space of the test facility which is a 24 foot (7.3m) high, steam heated inner cylinder of three foot (.91m) diameter and five and half foot (1.7m) diameter outer cylinder. Comparison of CONTEMPT-NPR and WGOTHIC was done for reduced scale NPR