WorldWideScience

Sample records for partially polyurethane-covered stent

  1. Polyurethane-Covered Self-expandable Nitinol Stent for Malignant Biliary Obstruction: Preliminary Results

    International Nuclear Information System (INIS)

    Han, Young-Min; Hwang, Seung-Bae; Lee, Soo-Teik; Lee, Jeong-Min; Chung, Gyung-Ho

    2002-01-01

    Purpose: To evaluate the immediate and long-term results in ten patients with malignant biliary obstruction using a polyurethane-covered, self-expandable nitinol stent.Methods: A nitinol stent, fully covered with high-elasticity polyurethane, with an unconstrained diameter of 10 mm and a total length of 60-80 mm, was placed transhepatically under fluoroscopic guidance in ten patients. The length of the biliary obstruction varied between 30-50 mm. The follow-up examination included a clinical assessment, serum bilirubin measurement, and ultrasound examinations at one-month intervals in all patients. Results: Initial stent deployment was successful in eight patients. Two patients experienced proximal migration,which was solved by insertion of two, uncovered Wallstents. One patient had the stent removed after two weeks because of severe nausea and vomiting. One patient had delayed migration of the covered stent after 40 weeks. The follow-up duration was 3-40 weeks (Mean: 16.9 weeks). Seven patients died(3-26 weeks) and three patients survived (24-40 weeks). The bilirubin measurements in all patients had significantly decreased one week after stent insertion. The levels of amylase and lipase had did not increase after stent insertion. Conclusions: Apolyurethane-covered, self-expandable nitinol stent can be used effectively and safely in the treatment of malignant biliary obstruction. The preliminary results are favorable, but there is a need for further large studies to determine both long-term survival and patency

  2. Evaluation of the biodurability of polyurethane-covered stent using a flow phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun; Kang, Sung Gwon; Choi, Jung Ryul; Byun, Ju Nam; Kim, Young Chul [Chosun University Hospital, Gwangju (Korea, Republic of); Ahn, Young Moo [Hansung Universkty, Seoul (Korea, Republic of)

    2001-06-01

    To evaluate the biodurability of the covering material in retrievable metallic stents covered with polycarbonate polyurethane. Using a peristaltic pump at a constant rate of 1ml/min, bile was recirculated from a reservoir through a long tube containing four stents. Each of these was removed from the system every two weeks and a radial tensile strength test and scanning electron microscopy (SEM) were performed. Each stent, removed at 2, 4, 6 and 8 weeks, was compared with a control stent not exposed to bile juice. Gross examination showed that stents were intact at 2 weeks, but at 4, 6 and 8 weeks cracks were observed. The size of these increased gradually in accordance with the duration of exposure, and at 8 weeks several large holes in the polyurethane membrane were evident. With regard to radial tensile strength, extension and peak load at break were 84.47% and 10.030 N/mm, 54.90% and 6.769 N/mm, 16.55% and 2.452 N/mm, 11.21% and 1.373 N/mm at 0, 2, 4 and 6 weeks, respectively. Scanning electron microscopy at 2 weeks revealed intermittent pitting and cracking, and examination at 4, 6 and 8 weeks showed that the size of these defects was gradually increasing. When the polyurethane membrane was exposed to bile, biodegradation was first observed at week two and increased gradually according to the duration of exposure.

  3. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    Science.gov (United States)

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  4. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

    Science.gov (United States)

    Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

  5. Treatment of Complete and Partial Obstruction of the Nasolacrimal System with Polyurethane Stents: Initial Experience

    International Nuclear Information System (INIS)

    Pulido-Duque, Juan M.; Reyes, Ricardo; Carreira, Jose M.; Vega, Francisco; Gorriz, Elias; Pardo, M. Dolores; Perez, Francisco; Maynar, Manuel

    1998-01-01

    Purpose: To present our experience in the treatment of nasolacrimal occlusion by means of polyurethane stents. Methods: Forty polyurethane stents were placed under fluoroscopic guidance in 35 consecutive patients with epiphora due to total or partial obstruction of the nasolacrimal system. The set designed by Song was used in all patients. The procedure was performed by introducing a guidewire through the superior punctum into the canaliculus and advancing it across the obstruction into the inferior meatus of the nasal cavity. After pulling out the guidewire, the stent was advanced in retrograde fashion and released into the sac and the nasolacrimal duct.Results: The technical success rate was 100%. The average time for the procedure was 25 min (range 10-60 min). Immediate complications were: mild pain (n= 5), severe pain (n= 1), minimal epistaxis (n= 7), and moderate epistaxis (n= 1). No major complications occurred. The last clinical control revealed complete resolution of epiphora in 35 eyes and partial resolution in four; one patient did not improve. Conclusion: This technique for treatment of obstruction of the nasolacrimal system is simple and safe, and may obviate the use of more invasive procedures

  6. Nasolacrimal Polyurethane Stent: Complications with CT Correlation

    International Nuclear Information System (INIS)

    Pinto, Isabel T.; Paul, Laura; Grande, Carlos

    1998-01-01

    Purpose: To evaluate initial results in patients with epiphora secondary to obstruction of the nasolacrimal duct treated by placement of a polyurethane stent, and to discuss the technical problems and complications arising during the procedure, with visualization of the anatomy of the drainage apparatus using computed tomography (CT). Methods: We inserted 20 polyurethane Song stents under fluoroscopic guidance after dacryocystography in 19 patients with grade 3-4 epiphora caused by idiopathic obstruction of the nasolacrimal duct. CT scans were obtained following stent placement in all patients. Results: We focus on the technical problems and complications that arose during these procedures. During negotiation of the guidewire past the obstruction at the level of the junction of the duct with the lacrimal sac, the guidewire created a false passage in a posterior suborbital direction in two cases and towards the posterior midline in another. In all cases the guidewire was withdrawn and reinserted through the proper anatomic route without further difficulty or complications. In two cases the stent was improperly positioned wholly or partially outside the nasolacrimal system (one medially, one posteriorly). In one case the stent was removed and reinserted; in the other it remains in place and functional. CT was performed in all these cases to ensure proper anatomic alignment and determine what had gone wrong. The epiphora was completely resolved in 13 cases and partially relieved in four; there were three cases of stent obstruction. Epistaxis of short duration (1 hr) occurred in seven patients and headache in one. Conclusions: Treatment of epiphora with polyurethane stents is a technique that is well tolerated by patients and achieves a high success rate, yet problems in placement may be encountered. Though no major consequences for patients are involved, cognizance of such difficulties is important to avoid incorrect positioning of stents

  7. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

    International Nuclear Information System (INIS)

    Ma, Ji; Han, Xinwei; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua

    2016-01-01

    PurposeTo evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis.Materials and MethodsWe conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal.ResultsA total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P   0.05).ConclusionTemporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  8. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis.

    Science.gov (United States)

    Ma, Ji; Han, Xinwei; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua

    2016-08-01

    To evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis. We conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal. A total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P  0.05). Temporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  9. Fully covered stents versus partially covered stents for palliative treatment of esophageal cancer: Is there a difference?

    Science.gov (United States)

    Alonso Lárraga, J O; Flores Carmona, D Y; Hernández Guerrero, A; Ramírez Solís, M E; de la Mora Levy, J G; Sánchez Del Monte, J C

    2018-02-26

    Malignant dysphagia is difficulty swallowing resulting from esophageal obstruction due to cancer. The goal of palliative treatment is to reduce the dysphagia and improve oral dietary intake. Self-expandable metallic stents are the current treatment of choice, given that they enable the immediate restoration of oral intake. The aim of the present study was to describe the results of using totally covered and partially covered esophageal stents for palliating esophageal cancer. A retrospective study was conducted on patients with inoperable esophageal cancer treated with self-expandable metallic stents. The 2 groups formed were: group A, which consisted of patients with a fully covered self-expandable stent (SX-ELLA ® ), and group B, which was made up of patients with a partially covered self-expandable stent (Ultraflex ® ). Of the 69-patient total, 50 were included in the study. Group A had 19 men and 2 women and their mean age was 63.6 years (range 41-84). Technical success was achieved in 100% (n=21) of the cases and clinical success in 90.4% (n=19). Group B had 24 men and 5 women and their mean age was 67.5 years (range 43-92). Technical success was achieved in 100% (n=29) of the cases and clinical success in 89.6% (n=26). Complications were similar in both groups (33.3 vs. 51.7%). There was no difference between the 2 types of stent for the palliative treatment of esophageal cancer with respect to technical success, clinical success, or complications. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats

    Directory of Open Access Journals (Sweden)

    Olavo Ribeiro Rodrigues

    2013-01-01

    Full Text Available PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.

  11. Malignant duodenal obstructions: palliative treatment with covered expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Chul; Jung, Gyoo Sik; Lee, Sang Hee; Kim, Sung Min; Oh, Kyung Seung; Huh, Jin Do; Cho, Young Duk [College of Medicine, Kosin Univ, Pusan (Korea, Republic of); Song, Ho Young [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-04-01

    To evaluate the feasibility and clinical effectiveness of using a polyurethane-covered expandable nitinol stent in the palliative treatment of malignant duodenal obstruction. Under fluoroscopic guidance, a polyurethane-covered expandable nitinol stent was placed in 12 consecutive patients with malignant duodenal obstructions. All presented with severe nausea and recurrent vomiting. The underlying causes of obstruction were duodenal carcinoma (n=4), pancreatic carcinoma (n=4), gall bladder carcinoma (n=2), distal CBD carcinoma (n=1), and uterine cervical carcinoma (n=1). The sites of obstruction were part I (n=1), part II (n=8), and III (n=3). Due to pre-existing jaundice, eight patients with part II obstructions underwent biliary decompression prior to stent placement. An introducer sheath with a 6-mm outer diameter and stents 16 mm in diameter were employed, and to place the stent, and after-loading technique was used. Stent placement was technically successful in ten patients, and no procedural complications occuured. In one of two patients in whom there was technical failure, and in whom the obstructions were located in part III, the stent was placed transgastrically. Stent migration occurred in one patient four days after the procedure, and treatment involved the palcement of a second, uncovered, nitinol stent. After stent placement, symptoms improved in all patients. During follow-up, obstructive symptoms due to stent stenosis (n=1), colonic obstruction (n=1), and multiple small bowel obstruction (n=1) recurred in three patients. Two of these were treated by placing additional stents in the duodenum and colon, respectively. One of the eight patients in whom a stent was placed in the second portion of the duodenum developed jaundice. The patients died a mean 14 (median, 9) weeks after stent placement. The placement of a polyurethane-covered expandable nitinol stent seems to be technically feasible, safe and effective for the palliative treatment of malignant

  12. Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks.

    Science.gov (United States)

    van Boeckel, Petra G A; Dua, Kulwinder S; Weusten, Bas L A M; Schmits, Ruben J H; Surapaneni, Naveen; Timmer, Robin; Vleggaar, Frank P; Siersema, Peter D

    2012-02-29

    Benign esophageal ruptures and anastomotic leaks are life-threatening conditions that are often treated surgically. Recently, placement of partially and fully covered metal or plastic stents has emerged as a minimally invasive treatment option. We aimed to determine the clinical effectiveness of covered stent placement for the treatment of esophageal ruptures and anastomotic leaks with special emphasis on different stent designs. Consecutive patients who underwent placement of a fully covered self-expandable metal stent (FSEMS), a partially covered SEMS (PSEMS) or a self-expanding plastic stent (SEPS) for a benign esophageal rupture or anastomotic leak after upper gastrointestinal surgery in the period 2007-2010 were included. Data on patient demographics, type of lesion, stent placement and removal, clinical success and complications were collected A total of 52 patients received 83 esophageal stents (61 PSEMS, 15 FSEMS, 7 SEPS) for an anastomotic leak (n=32), iatrogenic rupture (n=13), Boerhaave's syndrome (n=4) or other cause (n=3). Endoscopic stent removal was successful in all but eight patients treated with a PSEMS due to tissue ingrowth. Clinical success was achieved in 34 (76%, intention-to-treat: 65%) patients (PSEMS: 73%, FSEMS: 83%, SEPS: 83%) after a median of 1 (range 1-5) stent and a median stenting time of 39 (range 7-120) days. In total, 33 complications in 24 (46%) patients occurred (tissue in- or overgrowth (n=8), stent migration (n=10), ruptured stent cover (all Ultraflex; n=6), food obstruction (n=3), severe pain (n=2), esophageal rupture (n=2), hemorrhage (n=2)). One (2%) patient died of a stent-related cause. Covered stents placed for a period of 5-6 weeks may well be an alternative to surgery for treating benign esophageal ruptures or anastomotic leaks. As efficacy between PSEMS, FSEMS and SEPS is not different, stent choice should depend on expected risks of stent migration (SEPS and FSEMS) and tissue in- or overgrowth (PSEMS).

  13. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Ji; Han, Xinwei, E-mail: hanxinwei2006@163.com; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua [The First Affiliated Hospital of Zhengzhou University, Department of Interventional Radiology (China)

    2016-08-15

    PurposeTo evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis.Materials and MethodsWe conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal.ResultsA total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P < 0.05). The mean lumen transverse diameters of the stenotic site in trachea and main bronchus after stent removal (17.235 ± 3.457 and 8.993 ± 0.961 mm; 1 month post-removal; 16.353 ± 4.132 and 8.357 ± 1.082 mm; 6 months post-removal) were significantly larger than those before stent placement (7.876 ± 2.351 and 2.143 ± 0.770 mm, respectively; P < 0.05). However, the mean lumen diameters between 1 and 6 months after stent removal had no significant difference (P > 0.05).ConclusionTemporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  14. Fully-covered metal stents with endoscopic suturing vs. partially-covered metal stents for benign upper gastrointestinal diseases: a comparative study

    Science.gov (United States)

    Ngamruengphong, Saowanee; Sharaiha, Reem; Sethi, Amrita; Siddiqui, Ali; DiMaio, Christopher J.; Gonzalez, Susana; Rogart, Jason; Jagroop, Sophia; Widmer, Jessica; Im, Jennifer; Hasan, Raza Abbas; Laique, Sobia; Gonda, Tamas; Poneros, John; Desai, Amit; Wong, Katherine; Villgran, Vipin; Brewer Gutierrez, Olaya; Bukhari, Majidah; Chen, Yen-I; Hernaez, Ruben; Hanada, Yuri; Sanaei, Omid; Agarwal, Amol; Kalloo, Anthony N.; Kumbhari, Vivek; Singh, Vikesh; Khashab, Mouen A.

    2018-01-01

    Background and study aims  Self-expandable metallic stents (SEMS) have been increasingly used in benign conditions (e. g. strictures, fistulas, leaks, and perforations). Fully covered SEMS (FSEMS) were introduced to avoid undesirable consequences of partially covered SEMS (PSEMS), but come with higher risk of stent migration. Endoscopic suturing (ES) for stent fixation has been shown to reduce migration of FSEMS. Our aim was to compare the outcomes of FSEMS with ES (FS/ES) versus PSEMS in patients with benign upper gastrointestinal conditions. Patients and methods  We retrospectively identified all patients who underwent stent placement for benign gastrointestinal conditions at seven US tertiary-care centers. Patients were divided into two groups: FSEMS with ES (FS/ES group) and PSEMS (PSEMS group). Clinical outcomes between the two groups were compared. Results  A total of 74 (FS/ES 46, PSEMS 28) patients were included. On multivariable analysis, there was no significant difference in rate of stent migration between FS/ES (43 %) and PSEMS (15 %) (adjusted odds ratio 0.56; 95 % CI 0.15 – 2.00). Clinical success was similar [68 % vs. 64 %; P  = 0.81]. Rate of adverse events (AEs) was higher in PSEMS group [13 (46 %) vs. 10 (21 %); P  = 0.03). Difficult stent removal was higher in the PSEMS group (n = 5;17 %) vs. 0 % in the FS/ES group; P  = 0.005. Conclusions  The proportion of stent migration of FS/ES and PSEMS are similar. Rates of other stent-related AEs were higher in the PSEMS group. PSEMS was associated with tissue ingrowth or overgrowth leading to difficult stent removal, and secondary stricture formation. Thus, FSEMS with ES for stent fixation may be the preferred modality over PSEMS for the treatment of benign upper gastrointestinal conditions. PMID:29404384

  15. Partially Covered Metal Stents May Not Prolong Stent Patency Compared to Uncovered Stents in Unresectable Malignant Distal Biliary Obstruction

    Science.gov (United States)

    Kim, Jae Yun; Ko, Gyu Bong; Lee, Tae Hoon; Park, Sang-Heum; Lee, Yun Nah; Cho, Young Sin; Jung, Yunho; Chung, Il-Kwun; Choi, Hyun Jong; Cha, Sang-Woo; Moon, Jong Ho; Cho, Young Deok; Kim, Sun-Joo

    2017-01-01

    Background/Aims Controversy still exists regarding the benefits of covered self-expandable metal stents (SEMSs) compared to uncovered SEMSs. We aimed to compare the patency and stent-related adverse events of partially covered SEMSs (PC-SEMSs) and uncovered SEMSs in unresectable malignant distal biliary obstruction. Methods A total of 134 patients who received a PC-SEMS or uncovered SEMS for palliation of unresectable malignant distal biliary obstruction were reviewed retrospectively. The main outcome measures were stent patency, stent-related adverse events, and overall survival. Results The median stent patency was 118 days (range, 3 to 802 days) with PC-SEMSs and 105 days (range, 2 to 485 days) with uncovered SEMSs (p=0.718). The overall endoscopic revision rate due to stent dysfunction was 36.6% (26/71) with PC-SEMSs and 36.5% (23/63) with uncovered SEMSs (p=0.589). Tumor ingrowth was more frequent with uncovered SEMSs (4.2% vs 19.1%, p=0.013), but migration was more frequent with PC-SEMSs (11.2% vs 1.5%, p=0.04). The incidence of stent-related adverse events was 2.8% (2/71) with PC-SEMSs and 9.5% (6/63) with uncovered SEMSs (p=0.224). The median overall survival was 166 days with PC-SEMSs and 168 days with uncovered SEMSs (p=0.189). Conclusions Compared to uncovered SEMSs, PC-SEMSs did not prolong stent patency in unresectable malignant distal biliary obstruction. Stent migration was more frequent with PC-SEMSs. However, tumor ingrowth was less frequent with PC-SEMSs compared to uncovered SEMSs. PMID:28208003

  16. A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet Obstruction.

    Science.gov (United States)

    Takahara, Naminatsu; Isayama, Hiroyuki; Nakai, Yousuke; Yoshida, Shuntaro; Saito, Tomotaka; Mizuno, Suguru; Yagioka, Hiroshi; Kogure, Hirofumi; Togawa, Osamu; Matsubara, Saburo; Ito, Yukiko; Yamamoto, Natsuyo; Tada, Minoru; Koike, Kazuhiko

    2017-07-15

    Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.

  17. Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits

    International Nuclear Information System (INIS)

    Wilhelm, K.E.; Grabolle, B.; Urbach, H.; Tolba, R.; Schild, H.; Paulsen, F.

    2006-01-01

    The purpose of this study was to evaluate the radiographic and biological effects of different polyurethane nasolacrimal duct stents in an animal model. Fifteen polyurethane nasolacrimal duct stents (n = 5 mushroom-type stents, n = 5 newly designed S-shaped TearLeader stents without hydrophilic coating, and n = 5 S-shaped TearLeader stents with hydrophilic coating) were implanted in the nasolacrimal ducts of eight unaffected New Zealand rabbits. One nasolacrimal system served as control. Clinical and radiographic follow-up was performed at 1-, 2-, and 4-week intervals, then after a 3-month interval, after which the animals were euthanized. All stents were implanted without major periprocedural complications. The stents proved to be patent by the end of the procedure. During follow-up, all mushroom-type stents were occluded at 4 weeks. None of these stents opened to forced irrigation. Clinically, all rabbits demonstrated severe dacryocystitis. Three out of five TearLeader stents without hydrophilic coating were blocked at 4 weeks; one out of five was open to irrigation. Best results were observed in the stent group with hydrophilic coating. Follow-up dacryocystography demonstrated patent stents in nasolacrimal ducts of all animals after 4 weeks. In only one of five cases, the coated stent became partially occluded after 2 months. These animals were free of clinical symptoms. After 3 months, at least three out of five stents still opened to forced irrigation and only one stent was completely blocked. Dislocation of the stents was not observed. Refinement of the stent surface and stent design improves the results of nasolacrimal duct stenting in this animal model. Implantation of hydrophilic-coated S-shaped stents is highly superior to conventional mushroom-type stents and noncoated stent types. Hydrophilic coating seems to prevent foreign-body reactions, resulting in maximized stent patency

  18. Partially covered versus uncovered self-expandable nitinol stents with anti-migration properties for the palliation of malignant distal biliary obstruction: A randomized controlled trial.

    Science.gov (United States)

    Yang, Min Jae; Kim, Jin Hong; Yoo, Byung Moo; Hwang, Jae Chul; Yoo, Jun Hwan; Lee, Ki Seong; Kang, Joon Koo; Kim, Soon Sun; Lim, Sun Gyo; Shin, Sung Jae; Cheong, Jae Youn; Lee, Kee Myung; Lee, Kwang Jae; Cho, Sung Won

    2015-01-01

    Covered self-expandable metal stents (SEMSs) are increasingly used as alternatives to uncovered SEMSs for the palliation of inoperable malignant distal biliary obstruction to counteract tumor ingrowth. We aimed to compare the outcomes of partially covered and uncovered SEMSs with identical mesh structures and anti-migration properties, such as low axial force and flared ends. One hundred and three patients who were diagnosed with inoperable malignant distal biliary obstruction between January 2006 and August 2013 were randomly assigned to either the partially covered (n = 51) or uncovered (n = 52) SEMS group. There were no significant differences in the cumulative stent patency, overall patient survival, stent dysfunction-free survival and overall adverse events, including pancreatitis and cholecystitis, between the two groups. Compared to the uncovered group, stent migration (5.9% vs. 0%, p = 0.118) and tumor overgrowth (7.8% vs. 1.9%, p = 0.205) were non-significantly more frequent in the partially covered group, whereas tumor ingrowth showed a significantly higher incidence in the uncovered group (5.9% vs. 19.2%, p = 0.041). Stent migration in the partially covered group occurred only in patients with short stenosis of the utmost distal bile duct (two in ampullary cancer, one in bile duct cancer), and did not occur in any patients with pancreatic cancer. For the palliation of malignant distal biliary obstruction, endoscopic placement of partially covered SEMSs with anti-migration designs and identical mesh structures to uncovered SEMSs failed to prolong cumulative stent patency or reduce stent migration.

  19. Temporary urethral covered stent - third year of experience

    International Nuclear Information System (INIS)

    Stojanovis, V.; Maksimovis, H.; Markovis, B.; Markovis, Z.

    2006-01-01

    Full text: In October 2003, a new generation of urethral stents ALLIUM, produced in Israel, were used at the Department of Interventional Radiology, CCS, in 18 patients with chronic stricture of bulbar urethra. The indications for insertion were determined according to well-known and recognized therapeutical protocols. The stent is made of nitinol wire with polyurethane cover. It is inserted under local anesthesia by a special self-expandable system that may be fixed or flexible. The stents we used were 3-6 cm long and 28 Fr wide. Radioscopic-assisted insertion was performed over formerly placed metal guide. Prior to insertion, balloon-catheter dilatation of stricture matching the stent width was carried out. Pre-insertion urethrotomy was performed in one case. The insertion technique is simple, presupposing the knowledge of older generations of techniques of urethral dilatation and insertion of self-expandable stents. The follow-up of results was done according to a priori established protocol including the following: UCG, uroflowmetry and interview with patients. Due to stent migration, the 'stent over stent' technique was applied in one case, while reposition by balloon-catheter outward traction was performed in two cases of caudal migration. No irritative discomforts were reported in the first 4 months after stent dwelling. Uroflowmetric controls verified at least four times better results than before the insertion. Given it is the question of covered stent, there is no possibility of proliferative secondary lumen obstruction. On account of soft structure and conic shape of posterior part of stent, no lesions of the external urethral sphincter were manifested. The stent is simply withdrawn after 6 months by outward traction using the forceps at the time when the stent construction turns into soft and straight wire. The first clinical experiences are very favorable and ALLIUM stent may be expected to be the stent of choice for chronic bulbar strictures

  20. Unique usage of a partially covered metal stent for drainage of a pancreatic pseudocyst via endosonography-guided transcystgastrostomy.

    Science.gov (United States)

    Nici, Anthony J; Hussain, Syed A; Kim, Sang H; Mehta, Preeti

    2012-05-01

    Pancreatic pseudocysts are frequent complications of pancreatitis episodes. The current therapeutic modalities for drainage of pancreatic pseudocysts include surgical, percutaneous, and endoscopic drainage modalities. Endosonography-assisted endoscopic drainage of these pseudocysts with the placement of multiple plastic or fully covered self-expanding biliary metal stents is becoming more commonly carried out. The present case report discusses the unique and successful drainage of a pancreatic pseudocyst with the placement of a partially covered self-expanding metal stent. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  1. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon; Seo, Tae-Seok; Yuk, Soon Hong; Kim, Young-Hwa; Cho, Yong-Mee

    2005-01-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean±standard deviation, 46.88±23.75) than in the CS (73.75±14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63±2.05) than in CS (3.49±2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  2. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, Seoul (Korea); Seo, Tae-Seok [Gachon Medical School, Department of Radiology, Gil Medical Center, Inchon (Korea); Yuk, Soon Hong [Hannam University, Department of Polymer Science and Engineering, College of Engineering, Daejeon (Korea); Kim, Young-Hwa [Soonchunhyang University Chonan Hospital, Department of Radiology, Chonan (Korea); Cho, Yong-Mee [University of Ulsan College of Medicine, Department of Pathology, Asan Medical Center, Seoul (Korea)

    2005-06-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean{+-}standard deviation, 46.88{+-}23.75) than in the CS (73.75{+-}14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63{+-}2.05) than in CS (3.49{+-}2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  3. Assessment of bio-safety of low-cost polyurethane urologic stents used in developing countries.

    Science.gov (United States)

    Roy, Nobhojit; Waingankar, Santosh; Aggarwal, Gaurav

    2012-04-01

    Ureteral stents, despite their ubiquitous use, have not been evaluated for their safety and strength after removal from the patient. While literature is available from the industry with regards to manufacturing and specifications of stents, what happens to a stent after it is inserted into the body, still needs to be explored. We conducted a methodical study of 153 consecutive patients with urological problems who were stented with inexpensive polyurethane stents. Once removed from the patients, the stents were analyzed for breakload, tensile strength, elongation, pH, decomposition temperature, residue as well as diameter change. There was no significant change in the physical and mechanical properties of the stent after clinical use and the variance was within the acceptable range of biomaterials. There was minimal leaching of material and color change in all stents. The cheap polyurethane stents were found to be safe for use in patients, for the short time periods of in situ stenting. The degradation of physical and chemical properties of the stent was not significant. Thus it can be safely said that the stents currently in widespread use are cost-effective and physically safe for short spans of time.

  4. Intravascular stent graft with polyurethane and metallic stent: experimental study

    International Nuclear Information System (INIS)

    Do, Young Soo; Lee, Won Jae; Kim, Boo Kyung Han; Park, Jae Hyung; Lee, Hak Jong; Lee, Sang Hyun; Kim, Sung Hyun; Kim, Jong Won; Ha, Jongwon

    1997-01-01

    To evaluate the usefulness of a new model of the stent graft, and of tissue response related to placement of the stent graft. The stent graft was constructed from polyurethane (Pellethane) graft and Hanaro stent(12mm in diameter, 45mm in length, 10 bends). A stent grafts was inserted into the lower thoracic aorta in each of six adult mongrel dogs(body weight, 12-16kg). At one, two, four, and six months, follow-up studies of angiography and spiral CT angiography were preformed to evaluate wascular patency, vascular stenosis, and thrombus formation. Two dogs were sacrificed at 1month, 2months, and 6months after insertion of the stent graft and macroscopic, light microscopic, and scanning electron microscopic examinations of the aortic segment including the stent graft were performed to evaluate intimal hyperplasia, endothelial growth to the graft, and thrombus formation. During follow-up at one, two, four, and six months, angiography or spiral CT angiography showed 20-100% luminal stenosis or occlusion of the lower thoracic aorta by the thrombus and perigraft leaks in three dogs(50%), and collateral vessels caused by occlusion of the aorta in two (33.3%). On gross examination, there were thrombi of 1-5mm thickness at the graft portions in all dogs, and this thickness gradually increased. The mean thickness of intimal hyperplasia at the stent portion gradually increased from 120μm to 227μm and the mean thickness of intimal hyperplasia at the graft portion from 93μm to 914μm. This thickness was greater at the graft portion than at the stent portion. Scanning electron microscopy showed elliptical endothelial lining on the neointimal surfaces at each end of the graft. Thrombi caused stenosis or occlusion of the stent graft. In order for such a graft to be ideal, further study is needed

  5. Assessment of bio-safety of low-cost polyurethane urologic stents used in developing countries

    Directory of Open Access Journals (Sweden)

    Nobhojit Roy

    2012-01-01

    Full Text Available Background: Ureteral stents, despite their ubiquitous use, have not been evaluated for their safety and strength after removal from the patient. While literature is available from the industry with regards to manufacturing and specifications of stents, what happens to a stent after it is inserted into the body, still needs to be explored. Materials and Methods: We conducted a methodical study of 153 consecutive patients with urological problems who were stented with inexpensive polyurethane stents. Once removed from the patients, the stents were analyzed for breakload, tensile strength, elongation, pH, decomposition temperature, residue as well as diameter change. Results: There was no significant change in the physical and mechanical properties of the stent after clinical use and the variance was within the acceptable range of biomaterials. There was minimal leaching of material and color change in all stents. Conclusion: The cheap polyurethane stents were found to be safe for use in patients, for the short time periods of in situ stenting. The degradation of physical and chemical properties of the stent was not significant. Thus it can be safely said that the stents currently in widespread use are cost-effective and physically safe for short spans of time.

  6. Silicone covered vs. Non- covered endotracheal self expandable metallic stent: An experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Do, Young Soo; Lee, Byung Hee; Kim, Soo Ah; Kim, Kie Hwan; Chin, Soo Yil; Cho, Kyung Ja; Cho, Dae Soon [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1994-10-15

    To evaluate pathologic changes of the trachea and the lung after insertion of silicone covered and non covered Gianturco stent in the trachea of dog. Silicone covered(covered) and non covered(bare) Gianturco stent, six in each, were inserted into the tracheal lumen of six consecutive dogs. After 1-10 weeks observation, the dogs were sacrificed and their tracheas and lungs were examined grossly and histopathologically. Serial chest radiographs were performed to evaluate pneumonia and stent migration every 3-5 days. Pneumonia was observed in one of bare stent group and five of covered stent group. Stent migration was noted in three of covered stent group. In bare stent group, the epithelium of the trachea was markedly thickened by hyperplasia and stent was covered by granulation tissue from 6 weeks after stent insertion. Inflammation was focal at contact site between the stent and the trachea. In covered stent group, the epithelium was denuded at multiple areas and there were multifocal squamous metaplasia of the mucosa. Inflammatory reaction of the trachea was diffuse. Inflammatory reaction was more severe and stent migration was more frequent in covered stent group. The use of covered stent in the trachea should be studied further.

  7. Comparison of the occlusion of experiemntal craniojugular saccular aneurysms with covered stents

    International Nuclear Information System (INIS)

    Zhang Haixia; Li Minghua; Cheng Yingsheng; Fang Chun; Li Min

    2006-01-01

    Objective: To assess the effectiveness and biocompatibility of balloon-expanding, stainless steel stents covered with biomembrane (BM-SSS) and polyurethane membrane (PUM-SSS) in the treatment of experimental saccular aneurysms in a canine model and to observe the ablation of aneurysm with preservation of the parent vessel. Methods: Sixteen healthy mongrel canines were included in our study. 26 of 29 successful experimental aneurysms were treated with covered stents, another 3 were untreated to serve as controls. Altogether there were fourteen BM-SSS and twelve PUM-SSS were placed endovascularly in the common carotid arteries covering the orifice of the aneurysms. Control angiography was performed immediately after the procedure and after 2 weeks, 4 weeks and 12 weeks. According to grouping time, each aneurysm together with stented arteries was removed with animals alive for histopathological examination. Enumeration data was analyzed by Fisher's Exact Test using SPSS 10.0. Results: Before stent placement, angiography of the common carotid arteries showed round, saccular side-wall aneurysms and complex pattern of flow. Immediately after stent placement the aneurysmal pouches were no longer visible and the stented common carotid arteries remained widely patent. All controlled aneurysms and common carotid arteries have been patent and unchanged for 1 year. 13 of 14 stented common carotid arteries with BM-SSS and 3 of 12 with PUM-SSS remained widely patent. The complete patency rate of BM-SSS and PUM-SSS was significantly different (P=0.0008). Histological analysis indicated that all treated aneurysmal pouches were almost filled with thrombus, as well as with fibrotic reactive scar tissue. Stent wires were found to be located deep within the vessel wall and encased by an extension of the tunica intima. The endothelium of the two groups was already mature at 12 weeks, and various degree of degenerate cells were seen under the transmission electron microscopy. Conclusion

  8. Covered stent placement for the treatment of malignant superior vena cava syndrome: Is unilateral covered stenting and effective?

    International Nuclear Information System (INIS)

    Cho, Young Hoon; Gwon, Dong Il; Ko, Gi Young; Ko, Heung Kyu; Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Sung, Kyu Bo

    2014-01-01

    To evaluate the safety and efficacy of unilateral covered stent placement in patients with malignant superior vena cava (SVC) syndrome. Between October 2008 and November 2012, expanded polytetrafluoroethylene-covered stent placement for malignant SVC syndrome was performed in 40 consecutive patients (35 men and five women; mean age, 61.4 years; range, 35-81 years). All covered stents were unilaterally placed within the SVC or across the venous confluence when needed to relieve venous obstruction and prevent tumor overgrowth, regardless of patency of contralateral brachiocephalic veins. Stent placement was technically successful in all patients. There were no major complications. Of the 37 patients symptomatic prior to stent placement, 34 (92%) experienced complete symptomatic relief 1-8 days after stent placement. Of the 29 patients who underwent covered stent placement across the venous confluence, nine patients had patent contralateral brachiocephalic veins prior to stent placement. However, no sign of SVC obstruction or contralateral upper extremity venous thrombosis was observed during the follow-up period. Kaplan-Meier analysis revealed median patient survival of 163 days. Stent occlusion occurred in four (10%) of 40 patents. Cumulative stent patency rates at 1, 3, 6, and 12 months were 95%, 92%, 86%, and 86%, respectively. Unilateral covered stent placement appears to be a safe and effective method for treating malignant SVC syndrome, despite the location of SVC occlusion.

  9. Covered stent placement for the treatment of malignant superior vena cava syndrome: Is unilateral covered stenting and effective?

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Hoon; Gwon, Dong Il; Ko, Gi Young; Ko, Heung Kyu; Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Sung, Kyu Bo [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2014-02-15

    To evaluate the safety and efficacy of unilateral covered stent placement in patients with malignant superior vena cava (SVC) syndrome. Between October 2008 and November 2012, expanded polytetrafluoroethylene-covered stent placement for malignant SVC syndrome was performed in 40 consecutive patients (35 men and five women; mean age, 61.4 years; range, 35-81 years). All covered stents were unilaterally placed within the SVC or across the venous confluence when needed to relieve venous obstruction and prevent tumor overgrowth, regardless of patency of contralateral brachiocephalic veins. Stent placement was technically successful in all patients. There were no major complications. Of the 37 patients symptomatic prior to stent placement, 34 (92%) experienced complete symptomatic relief 1-8 days after stent placement. Of the 29 patients who underwent covered stent placement across the venous confluence, nine patients had patent contralateral brachiocephalic veins prior to stent placement. However, no sign of SVC obstruction or contralateral upper extremity venous thrombosis was observed during the follow-up period. Kaplan-Meier analysis revealed median patient survival of 163 days. Stent occlusion occurred in four (10%) of 40 patents. Cumulative stent patency rates at 1, 3, 6, and 12 months were 95%, 92%, 86%, and 86%, respectively. Unilateral covered stent placement appears to be a safe and effective method for treating malignant SVC syndrome, despite the location of SVC occlusion.

  10. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  11. Total loss of the covering of a metallic stent during esophageal leak treatment

    Directory of Open Access Journals (Sweden)

    J.J. Villarreal-Galvan

    2013-01-01

    Full Text Available A 41-year-old man underwent a Heller myotomy due to achalasia. An unexpected puncture in the esophageal wall was identified during the procedure. A partially covered 15 cm stent (PSEMS (UltraFlex was placed at the mucosal defect. It was removed 26 days later and the endoscopic image showed esophageal tissue embedded in the covered portion of the stent. PSEMS covering loss is a rare complication that can have serious consequences.

  12. Experimental research of covered stent implanted in canine hepatic artery

    International Nuclear Information System (INIS)

    Zhou Bing; Liu Linxiang; Li Minghua; Wang Yongli; Cheng Yongde

    2007-01-01

    Objective: To evaluate the feasibility of success rate of implantation, post-procedure stenosis rate, apposition ability and endothelialization level, etc. for implantation with balloon-expandable covered stent in canine hepatic artery. Methods: 8 adult canines were implanted with balloon-expendable stents covered by expandable poly Teflon ester membrane (e-PTFEM). Follow-up DSA was performed immediately, 2, 4 and 12 wk after the procedure. The canines were sacrificed for histopathologic examination and statistical analysis with correlation of implantation manenvor and angiographic manifestations. Results: 8 cases were all implanted with the covered stents in proper hepatic artery/right hepatic artery successfully; showing good apposition ability and non-opacification of the separated branches. 2 cases showed intraluminal obvious stenosis( > 50%)of the stent at 2 weeks follow-up, so did 3 cases at 12 weeks follow-up, and the total stenosis rate was 37.5% and 5 cases manifested full endothelialization (3 different locations of the sample all manifested full endothelialization), 3 cased manifested partial endothelialization (at least 1 location of the sample didn't show full endothelialization), and the two terminal parts were easier to get endothelialization than the central part. Before and after the stent implantation, hepatic function of all cases didn't demonstrate any obvious changes. Conclusions: Balloon-expandable covered stent can be implanted in canine hepatic artery. successfully, with good apposition ability, full endothelialization, and no influence on hepatic function. (authors)

  13. Sealing of Airway Fistulas for Metallic Covered Z-type Stents

    Directory of Open Access Journals (Sweden)

    Hongwu WANG

    2011-08-01

    Full Text Available Background and objective Treating airway fistulas, including esophagorespiratory fistulas (ERFs, bronchopleural fistulas (BPFs, and tracheomediastinal fistulas (TMFs, is difficult. The aim of this study is to evaluate the safety and clinical efficacy of metallic covered Z-type stents (CZTS for the treatment of airway fistulas through bronchoscopy or fluroscopy. Methods Thirty-eight patients with fistulas between the esophagus, mediastina, and airways (32 ERFs, 5 BPFs, and 1 TMF were retrospectively reviewed after treatment with covered metallic esophageal and airway stents. The fistulas were caused by esophageal (n=26, bronchogenic (n=11, and thyroid (n=1 carcinomas. Results Forty-six fistulas were found in 38 patients. The fistula size ranged from 0.5 cm to 7.0 cm. Forty airway covered metal stents (24 Y-type, 8 L-type, and 8 I-type and 24 esophageal metal stents were placed. Complete responses to the sealing effects of fistulas were noted in 4.3% of all the fistulas, 60.9% showed complete clinical responses, 23.9% showed partial responses, and 10.9% showed no response. An effectivity rate of 89.1% was observed, and the median survival duration of all patients was 5 months. Conclusion The use of CZTS appears to be safe and feasible for the palliative treatment of ERFs, BPFs, and TMFs. Airway stent placement is recommended for patients with ERF. In the event that airway stents fail, esophageal stents should be given. Airway bifurcation stents were observed to be especially suitable for the sealing of fistulas near the trachea carina.

  14. A fully-covered stent (Alimaxx-E) for the palliation of malignant dysphagia: a prospective follow-up study

    NARCIS (Netherlands)

    Uitdehaag, Madeleen J.; van Hooft, Jeanin E.; Verschuur, Els M. L.; Repici, Alessandro; Steyerberg, Ewout W.; Fockens, Paul; Kuipers, Ernst J.; Siersema, Peter D.

    2009-01-01

    Background: The majority of the Currently available metal stents are partially covered to reduce migration risk. However, one of the remaining issues is tissue ingrowth through the uncovered stent parts. Objective: To determine efficacy, recurrent dysphagia, and complications of a fully covered

  15. The mechanics and biocompatibility characteristics of carbon nanotubes-polyurethane composite membranes:a preliminary study

    International Nuclear Information System (INIS)

    Dong Sheng; Yuan Zheng; Wu Shengwei; Li Wenxin

    2011-01-01

    Objective: To discuss the mechanics and biocompatibility characteristics of carbon nanotubes-polyurethane composite membranes. Methods: The mechanics property of carbon nanotubes-polyurethane composite membranes with different carbon nanotubes contents were tested by universal material testing machine. The surface of the membranes was observed by electron microscope when the stent was bent 90 degree. And its cytotoxicity was tested by cultivating study with 7721 cell. The metallic stent that was covered with carbon nanotubes-polyurethane composite membrane by using dip-coating method was inserted in rabbit esophagus in order to evaluate its biocompatibility in vivo. Results: Composite membranes tensile strength (MPa) and elongation at break (%) were 4.62/900, 6.05/730, 8.26/704 and 5.7/450 when the carbon nanotubes contents were 0%, 0.1%, 0.3% and 0.5%, respectively. If the stent was bent at 90 degree, its surface was still smooth without any fractures when it was scanned by electron microscope.Composite membranes had critical cytotoxicity when its carbon nanotubes content was up to 0.5% and 1.0%. No fissure nor degradation of composite membranes occurred at 30 days after composite membrane covered metallic stent was inserted in rabbit esophagus. Conclusion: When moderate carbon nanotubes are added into polyurethane composite membrane, the mechanics and biocompatibility characteristics of the polyurethane composite membrane can be much improved. (authors)

  16. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Park, Hyungkeun

    2006-01-01

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8±42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  17. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo [Asan Medical Center, Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea); Park, Hyungkeun [Asan Medical Center, Department of Urology, University of Ulsan College of Medicine, Seoul (Korea)

    2006-09-15

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8{+-}42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  18. Comparison of a New Polytetrafluoroethylene-Covered Metallic Stent to a Noncovered Stent in Canine Ureters

    International Nuclear Information System (INIS)

    Chung, Hwan-Hoon; Lee, Seung Hwa; Cho, Sung Bum; Park, Hong Suk; Kim, Young Sik; Kang, Byung Chul; Frisoli, Joan K.; Razavi, Mahmood K.

    2008-01-01

    The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first six dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted

  19. Synthesis and Properties of Some polyurethane/ Partially Aromatic Polyester Casting Samples

    International Nuclear Information System (INIS)

    Sadek, E.M.; Mazroua, A.M.; Emam, A.S.; Motawie, A.M.

    2005-01-01

    A series of partially aromatic terephthalate polyesters were synthesized by melt transesterification of dimethyl terephthalate with various types of aliphatic diol compounds in 1:1.1 molar ratio. Ethylene-, di-, tri-, tetra ethylene glycol and polyethylene glycol with different molecular weights 1000, 4000, 6000 as well as the prepared dihydroxy natural rubber were used. Another series of partially aromatic adipate and sebacate polyesters based on the prepared bisphenol A and its tetrabromo derivative were also synthesized by direct polycondensation esterification with adipic and sebacic acid. Polyurethane with NCO/OH ratio equal 4 was prepared from the reaction of 2,4 toluene diisocyanate with polyethylene glycol 1000. The prepared polyurethane was mixed with different weight percentages (2, 4, 6, 8, 10 or 12 % w/w) of the prepared partially aromatic polyesters to give polyurethane/polyester compositions. Mechanical and electrical properties as well as water and chemical resistance of the prepared film samples with thickness 3-4 mm were determined and compared with those of polyurethane film sample without polyester. The data indicate that 10 % w/w of the added partially aromatic polyester increases polyurethane tensile strength, improves its insulation properties and hydrolytic stability as well as its chemical resistance. Film samples based on bisphenol A impart excellent properties as compared with those based on aliphatic glycol species and dihydroxy natural rubber. Keywords: Partially aromatic polyesters, Dimethyl terephthalate, Glycols, Bisphenol A, Tetrabromo bisphenol A, Natural rubber, Adipic acid, Sebacic acid, Polyurethane, Casting

  20. A comparison of clinical efficacy between covered stent-grafts and bare stents in transjuglar in-trahepatic portosystemic shunt

    International Nuclear Information System (INIS)

    Jiang Yongbin; Zhang Xitong; Zhang Wei; Xia Yonghui; Liang Songnian; Xu Ke

    2010-01-01

    Objective: To compare the clinical efficacy between covered stent and uncovered stent in transjuglar in-trahepatic portosystemic shunt (TIPS). Methods: Thirty patients with liver cirrhosis (portal hypertension), who received TIPS, were retrospectively studied. All patients were divided into two groups covered-stent group (n=20) and uncovered-stent group (n=10). For each patient, portal pressure was measured before and after operation, and the patency of shunt was evaluated by color Doppler ultrasound after operation. The mortality, recurrent bleeding rate and incidence of hepatic encephalopathy were analyzed by Fisher exact probability test. Results: The TIPS treatment was successful in all patients, the portal pressure in the covered-stent group reduced from (3.78 ± 0.50)kPa to (2.13 ± 0.44) kPa and that of the uncovered-stent group reduced from (3.67 ± 0.48)kPA TO (2.13 ± 0.35)kPa. Twenty-six cases were postoperatively followed-up (17 cases in covered-stent group, 9 cases in uncovered-stent group). the follow-up period varied from 7 days to 62 months (median follow-up period was 23 months). Thirteen patients died of upper gastrointestinal bleeding and hepatic failure. The difference of mortality between covered-stent group (8/17) and uncovered-stent group (5/17) and the uncovered-stent group (3/9) was not different too (P>0.05). The incidence of hepatic encephalopathy in the covered-stent group (4/17) was not different from that of the uncovered-stent group (2/9) (P>0.05). The patency rates of 6 months and 12 months reached 100% in the covered-stent group, which were higher than those in the uncovered-stent group 77.8% (7/9) and 55.6%(5/9) (P<0.05). Conclusions: The patency rate of shunt at 12 months after TIPS was higher in the covered-stent group than the uncovered-stent group, while the mortality, recurrent bleeding rate and incidence of hepatic encephalopathy were not significantly different between the two groups. (authors)

  1. Usefulness of flexible covered stent in malignant colorectal obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jee Hee; Kang, Sung Gwon; Kim, Hyung Jin; Noh, Hong Gi; Woo, Jae Hong; Suh, Chang Hae [Inha Univ. Hospital, Inchon (Korea, Republic of)

    1998-07-01

    To evaluate the usefulness of flexible covered stent in the treatment of acute colorectal obstruction secondary to colorectal carcinoma. Materials and Methods : Flexible covered stents were placed in 11 patients with clinical and radiologic signs of acute colonic obstruction secondary to colorectal carcinoma. The purposes of stent insertion were pre-operative bowel preparation in seven patients and palliative treatment in four. A fistula was present in two;in one this was between the proximal jejunum and colon, and the other was rectovaginal. The usefulness of stent insertion for the purpose of preoperative bowel preparation was evaluated according to the feasibility and status of bowel preparation, as decided by the operator. Palliative treatment for the relief of symptoms of acute bowel obstruction was evaluated according to the number and amount of defecation,bowel dilatation in simple abdomen radiography, and the presence of complications. Results : Bowel preparation for the purpose of preoperative bowel cleansing was easy in seven patients;the fecal materials remaining in the colon presented no problems during surgery. In one of four patients palliative treatment involved a colostomy;this was due to recurrent stent obstruction by fecal materials after three months, and in two other patients there was stent obstruction after two and five months, respectively. The stent in one of four patients who underwent palliative treatment was removed because of stent migration three days after insertion;the stents in two patients with fistulas covered the fistulas successfully. Complications after stent insertion were anal pain in three patients, anal bleeding in three and stent migration in one. Conclusion : The flexible covered stent was an effective device for the relief of acute colonic obstruction secondary to malignant rectosigmoid neoplasia. It allowed for single-stage operation and covered the fistula. We believe however that for further evaluation of the

  2. Long-term patency of experimental magnetic compression gastroenteric anastomoses achieved with covered stents.

    Science.gov (United States)

    Cope, C; Ginsberg, G G

    2001-06-01

    Our aim was to evaluate the efficacy of a prototype "YO-YO"-shaped covered stent for keeping experimental magnetic compression gastroenteric fistulas patent for 6 months. Magnets were introduced perorally with endoscopic and fluoroscopic guidance and were mated across the gastric and jejunal walls of 5 dogs. After a mean of 5.5 days a 12-mm diameter YO-YO stent was placed perorally in the resulting fistula. The gastroenteric anastomosis (GEA) with stent was observed endoscopically and gastrographically at 1- to 2-month intervals. There was no morbidity and there were no significant weight changes. The GEA was widely patent at necropsy at 6 months (n = 4); partial membrane separation occurred at 5 months in the fifth dog. There was minor breakage of the stent prongs in 2 animals. Peroral creation of a stented magnetic compression GEA is safe and provides long-term patency. This technique may be potentially useful for managing gastric outlet obstruction caused by malignancy.

  3. Influence of covered stent versus bare stent on long-term efficacy of transjugular intrahepatic portosystemic shunt: a meta-analysis

    Directory of Open Access Journals (Sweden)

    XU Lu

    2016-10-01

    Full Text Available Objective To investigate the long-term postoperative efficacy of transjugular intrahepatic portosystemic shunt (TIPS using polytetrafluoroethylene (PTFE-covered stent or bare stent, and to provide a basis of evidence-based medicine for the selection of stent in TIPS. Methods CBM, Wanfang Data, CNKI, VIP, MEDLINE, and PubMed were searched for controlled trials on TIPS in the treatment of cirrhotic portal hypertension published form 1989 to 2015; the studies which met the inclusion criteria were selected, and quality assessment was performed for these articles. RevMan 5.3 software was used to analyze the incidence rates of stent dysfunction and hepatic encephalopathy and 1-year survival rate after TIPS, and funnel plots were used to analyze publication bias. Results A total of 11 studies were included, consisting of 698 patients in PTFE-covered stent group and 1283 patients in bare stent group. The results of the meta-analysis showed that the PTFE-covered stent group showed a significantly lower incidence rate of stent dysfunction than the bare stent group (14.8% vs 47.0%, OR=0.18, 95% CI: 0.13-0.24, P<0.001. There was no significant difference in the incidence rate of hepatic encephalopathy between the two groups (23.5% vs 25.7%, OR=0.88, 95% CI: 0.66-1.17, P=0.37. The PTFE-covered stent group had a significantly higher 1-year survival rate than the bare stent group (76.9% vs 62.7%, OR=2.10, 95% CI: 1.54-2.85, P<0.001. The funnel plots which were plotted based on the incidence rates of stent dysfunction and hepatic encephalopathy and 1-year survival rate lacked symmetry, which suggested that a certain degree of publication bias might exist. Conclusion Compared with the bare stent, the PTFE-covered stent can improve stent dysfunction and 1-year survival rate after TIPS, while there is no significant change in the incidence rate of hepatic encephalopathy. Therefore, the PTFE-covered stent has certain advantages over the bare stent in TIPS. In

  4. Esophagorespiratory fistula: treatment with self-expanding covered stent

    International Nuclear Information System (INIS)

    Zang Jian; Dou Yongchong; Wang Zheng; Kong Jian

    2002-01-01

    Objective: To evaluate self-expanding covered stent in the management of esophagorespiratory fistula. Methods: A self-expanding esophageal covered stent was implanted under fluoroscopic guidance in 13 patients with esophagorespiratory fistula. In this series patients aged 31-73 years (60.2 years in average). All patients had a pre-procedure fast of 6-41 days (17.3 days in average), in which 12 patients had pulmonary infection. Results: All fistulas were excluded and swallowing function was restored. No stend-related complication was observed. Pulmonary infection was managed in 10 patients out of 13. The mean survived time was 33.3 wks (1-178 wks) in follow-up. Conclusion: Covered self-expanding stent implantation is a safe and effective treatment of ERF

  5. Self-expandable covered metallic esophageal stent impregnated with beta-emitting radionuclide: an experimental study in canine esophagus

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Doo; Wang, Hee Jung; Kim, Gui-Eon; Kim, Bong Wan; Yim, Hyunee; Han, Sang Keon; Park, Chan H.; Joh, Chul Woo; Kim, Kyung-Hwa; Park, Kyung Bae; Shin, Kyong-Min

    2002-01-01

    Purpose: A specially designed self-expandable covered metallic stent impregnated with the β-emitting radioisotope 166 Ho ( 166 Ho, energy: 1.85 and 1.76 MeV, T((1)/(2)): 26.8 h) was developed at our institute for the purpose of intraluminal palliative brachytherapy, as well as for treating malignant esophageal stricture and swallowing difficulty. The aim of this study was to evaluate the tissue response to brachytherapy and the safety of the radioactive metallic stent with regard to the normal canine esophagus before clinical application. Methods and Materials: 166 Ho was impregnated into the polyurethane membrane (50 μ thickness) covering the outer surface of a self-expandable metallic stent (diameter, 18 mm; length, 40 mm). Stents with radioactivity 4.0-7.8 mCi (Group A, n=15), 1.0-1.8 mCi (Group B, n 5), and 0.5-0.7 mCi (Group C, n=5) were placed in the esophagi of 25 healthy beagle dogs, and the stents were tightly anchored surgically to prevent migration. The estimated radiation dose calculated by Monte Carlo simulation was 194-383 Gy in Group A, 48-90 Gy in Group B, and 23-32 Gy in Group C. The dogs were killed 8-12 weeks after insertion of the stents, and histologic examinations of the esophageal walls were performed. Results: In Group A, 3 of 15 dogs died of wound infection, so specimens were obtained from only 12 dogs; all 12 cases showed esophageal stricture with mucosal ulceration. Microscopically, severe fibrosis and degeneration of the muscular propria were found in 3 dogs, complete fibrosis of the entire esophageal wall was found in 7 dogs, and esophageal fibrosis with radiation damage within periesophageal soft tissue was found in 2 dogs. However, esophageal perforation did not develop, despite extremely high radiation doses. In Group B, glandular atrophy and submucosal fibrosis were found, but the muscular layer was intact. In Group C, no histologic change was found in 3 dogs, but submucosal inflammation and glandular atrophy with intact mucosa

  6. Comparison between uncovered and covered self-expandable metal stent placement in malignant duodenal obstruction.

    Science.gov (United States)

    Kim, Ji Won; Jeong, Ji Bong; Lee, Kook Lae; Kim, Byeong Gwan; Ahn, Dong Won; Lee, Jae Kyung; Kim, Su Hwan

    2015-02-07

    To compare the clinical outcomes of uncovered and covered self-expandable metal stent placements in patients with malignant duodenal obstruction. A total of 67 patients were retrospectively enrolled from January 2003 to June 2013. All patients had symptomatic obstruction characterized by nausea, vomiting, reduced oral intake, and weight loss. The exclusion criteria included asymptomatic duodenal obstruction, perforation or peritonitis, concomitant small bowel obstruction, or duodenal obstruction caused by benign strictures. The technical and clinical success rate, complication rate, and stent patency were compared according to the placement of uncovered (n = 38) or covered (n = 29) stents. The technical and clinical success rates did not differ between the uncovered and covered stent groups (100% vs 96.6% and 89.5% vs 82.8%). There were no differences in the overall complication rates between the uncovered and covered stent groups (31.6% vs 41.4%). However, stent migration occurred more frequently with covered than uncovered stents [20.7% (6/29) vs 0% (0/38), P stent patency was longer in uncovered than in covered stents [251 d (95%CI: 149.8 d-352.2 d) vs 139 d (95%CI: 45.5 d-232.5 d), P stent (70 d) and covered stent groups (60 d). Uncovered stents may be preferable in malignant duodenal obstruction because of their greater resistance to stent migration and longer stent patency than covered stents.

  7. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    International Nuclear Information System (INIS)

    Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.

    2011-01-01

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  8. Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture

    International Nuclear Information System (INIS)

    Wang Zhongmin; Huang Xunbo; Cao Jun; Huang Gang; Chen Kemin; LIu Yu; Liu Fenju

    2012-01-01

    Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.

  9. Therapeutic evaluation of retrievable esophageal covered stent in treating achalasia

    International Nuclear Information System (INIS)

    Li Yuwei; Zhang Fuqiang; Yuan Liang; Li Yunhui; Luo Bin; Yu Li; Sun Dingqiang

    2010-01-01

    Objective: To evaluate the clinical effect of retrievable esophageal covered metal internal stent in treating patients with achalasia. Methods: Under DSA guidance, peroral 'Z-type' double horn covered metal internal stent implantation was performed in 16 patients with achalasia. Esophagography was carried out about 28 days after the procedure and the stent was retrieved. Results: Of 16 cases, the stent fell off into the stomach two weeks after the operation in one. And the stent was successfully replaced after it was taken out. The placed stent was successfully retrieved in all cases 28 days after the treatment. No serious complications occurred. All the patients were followed up for 3 months to 3 years. During the follow-up period restenosis of the esophagus developed in two cases (at one and 1.5 years respectively), and the restenosis degree was relived after balloon dilation. Clinically, no esophageal symptoms, such as dysphagia, occurred in all patients. Conclusion: As a simple and safe technique, the retrievable esophageal covered metal internal stent implantation is very effective with fewer complications for the treatment of achalasia. Moreover, the technique carries lower restenosis occurrence. (authors)

  10. Treatment of esophagopleural fistulas using covered retrievable expandable metallic stents.

    Science.gov (United States)

    Kim, Tae-Hyung; Shin, Ji Hoon; Kim, Kyung Rae; Park, Jung-Hoon; Kim, Jin Hyoung; Song, Ho-Young

    2014-04-01

    To evaluate the clinical efficacy of placement of covered retrievable expandable metallic stents for esophagopleural fistulas (EPFs). During the period 1997-2013, nine patients with EPF were treated using covered retrievable expandable metallic stents. The underlying causes of EPF were esophageal carcinoma (n = 6), lung cancer (n = 2), and postoperative empyema for Boerhaave syndrome (n = 1). Technical success was achieved in eight patients (88.9%). In one patient, incomplete EPF closure was due to incomplete stent expansion. Clinical success, defined as complete EPF closure within 7 days, was achieved in five patients (55.6%). Overall fistula persistence (n = 1) or reopening (n = 4) occurred in five patients (55.6%) 0-15 days after stent placement. The causes of reopening were due to the gap between the stent and the esophagus (n = 3) or stent migration (n = 1). For fistula persistence or reopening, additional interventional management, such as gastrostomy, stent removal, or stent reinsertion, was performed. Stent migration occurred as a complication in one patient with EPF from a benign cause secondary to postoperative empyema. In the eight patients who died during the follow-up period, the mean and median survival times were 78.8 days and 46 days, respectively. Placement of a covered expandable metallic esophageal stent for the palliative treatment of EPF is technically feasible, although the rate of clinical success was poor secondary to fistula persistence or reopening. Fistula reopening was caused by the gap between the stent and the esophagus or by stent migration, and additional interventional treatment was useful to ensure enteral nutritional support. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  11. Stent placement of gastroenteric anastomoses formed by magnetic compression.

    Science.gov (United States)

    Cope, C; Clark, T W; Ginsberg, G; Habecker, P

    1999-01-01

    To evaluate the use of stents for prolonging the patency of gastroenteric anastomoses (GEA) induced by magnet compression. Rare earth magnets were inserted perorally and serially in 15 dogs so as to mate across the gastric and jejunal walls. After magnet excretion, the resulting GEA was identified endoscopically, dilated (n = 1), and stented with bare (n = 2) or partially covered (n = 6) flared 10-mm or 12-mm Z stents. The GEA was followed at 2-4-week intervals for patency; malfunctioning shunts were irrigated, or dilated with angioplasty balloons. Gross and histologic examination of the anastomotic tissues was performed in 14 animals. Magnet pairs were excreted in 5-7 days. Of the 19 magnet placements in 15 animals, stent placement was not possible because of early GEA closure (n = 6), failure to locate (n = 2), pancreatic abscess (n = 1), and magnet perforation with peritonitis (n = 1). Estimated duration of GEA patency was 19 days after balloon dilation, 40-64 days with bare Z stents, and 58-147 days (mean, 90 days) with partially covered Z stents. Shunt function was commonly hindered by bezoars. Stent narrowing or occlusion was caused by tissue overgrowth through bare stents (n = 2), between covered stent struts and through partially detached membrane (n = 2). Serious morbidity (n = 2) was due to malpositioned magnets across the pancreas in one animal and gastric perforation in the other. One dog was euthanized because of unsuspected kidney infection. Partially covered stents significantly extend the anatomic patency rate of magnetic GEA to 7 weeks or more. Functional patency is frequently impaired by bezoars. Ongoing improvements in covered stent design should provide longer-term GEA patency.

  12. Self-Expandable Metal Stents and Trans-stent Light Delivery: Are Metal Stents and Photodynamic Therapy Compatible?

    Science.gov (United States)

    Wang, Luo-Wei; Li, Li-Bo; Li, Zhao-Shen; Chen, Yang K; Hetzel, Fred W.; Huang, Zheng

    2008-01-01

    Background and Objectives: Obstructive non-small cell lung cancer and obstructive esophageal cancer are US FDA approved indications of photodynamic therapy (PDT). The usefulness of PDT for the treatment of cholangiocarcinoma is currently under clinical investigation. Endoscopic stenting for lumen restoration is a common palliative intervention for those indications. It is important to assess whether self-expandable metal stents are compatible with trans-stent PDT light delivery. Study Design/Materials and Methods: Direct effects of various components of metal biliary (n = 2), esophageal (n = 2), and bronchial (n = 1) stents on PDT light transmittance and distribution were examined using a point or linear light source (630 or 652 nm diode laser). Resected pig biliary duct and esophageal wall tissues were used to examine the feasibility of PDT light delivery through the fully expanded metal stents. Results: While using a point light source, the metal components (thread and joint) of the stent could cause a significant shadow effect. The liner material (polytetrafluoroethylene or polyurethane) could cause various degrees of light absorption. When the stent was covered with a thin layer of biliary duct and esophageal tissues containing all wall layers, the shadow effect could be mitigated due to tissue scattering. Conclusions: This study clearly demonstrates that it is feasible to combine stenting and PDT for the treatment of luminal lesions. PDT light dose should be adjusted to counteract the reduction of light transmittance caused by the metal and liner materials of stent. PMID:18951422

  13. Treatment of carotid artery aneurysms with covered stents; Aneurysmabehandlung der Arteria carotis interna mit gecoverten Stents

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, A.; Alfke, K.; Doerner, L.; Jansen, O. [UKSH Kiel (Germany). Neurochirurgie Neuroradiologie; Bartsch, T.; Stingele, R. [UKSH Kiel (Germany). Neurologie

    2007-10-15

    Purpose: Evaluation of the use of covered stents in treating pseudoaneurysms of the cervical and intracranial/extradural carotid artery and determination of the periprocedural and short- to mid-term complication rate. Materials and Methods: 8 patients with 9 spontaneous dissecting aneurysms of the cervical carotid artery - 5 of which were symptomatic - plus one patient with ofthalmoplegia due to an aneurysm of the cavernous carotid artery were studied. While the latter was treated with a PTFE-covered balloon-mounted stainless steel stent (Jostent/Graftmaster), a self-expanding PTFE-covered Nitonol Stent (Symbiot) was used in all other cases. Intervention was performed with local anesthesia. Aspirin and Clopidogrel were both used as antiplatelet drugs. Clinical signs and symptoms and vascular imaging with DS, MR, CT angiography and ultrasound were recorded during patient follow-up, with a mean follow-up period of 14.6 months (4 - 30). Results: We were able to treat 8 out of 10 aneurysms (80 %) using covered stents. The aneurysms were immediately occluded and the associated stenoses of the parent vessel were eliminated. No clinically relevant complications occurred during the procedure or in the follow-up interval. In two cases, elongation of the carotid artery prevented the stent from being positioned over the aneurysm neck. These cases were shown to be stable with the use of antiplatelet drugs. Conclusion: Covered stents can be used in the treatment of pseudoaneurysms of the carotid artery as an alternative to long-term antithrombotic medication or surgery. In our study treatment was effective (80 %) and free of complications in the short- and mid-term follow-up. Possible indications, technique and the use of imaging modalities for patient follow-up are discussed. (orig.)

  14. Comparison on the Efficacy between Partially Covered Self-Expandable Metal Stent with Funnel-Shaped Enlarged Head versus Uncovered Self-Expandable Metal Stent for Palliation of Gastric Outlet Obstruction

    Directory of Open Access Journals (Sweden)

    Jung Wan Choe

    2018-01-01

    Full Text Available Background. Shape modification has been one of the methods adopted to improve stent patency but has not always translated into positive outcome. The aim of this study was to compare the efficacy of shape-modified partially covered self-expandable metal stent (SEMS that has enlarged head versus uncovered SEMS for palliation of gastric outlet obstruction (GOO. Methods. A total of 48 patients underwent insertion of either enlarged-head SEMS (n=24 or uncovered SEMS (uSEMS (n=24 for palliation of GOO from July 2009 to July 2016. Patients with inoperable or advanced malignancy were included. Technical feasibility and clinical outcomes were compared. Results. Technical success rate was 100% (24/24 and 95.8% (23/24 for enlarged-head SEMS group and uSEMS group, respectively. Clinical success rate was 87.5% (21/24 and 87.0% (20/23 for enlarged-head SEMS group and uSEMS group, respectively. The gastric outlet obstruction scoring system score significantly improved in both groups (p<0.001 for both. Mean survival was similar between the groups: enlarged-head SEMS group, 99.3 days (range, 19–358 days versus uSEMS group, 82.1 days (range, 11–231 days (p=0.418. The mean stent patency also showed no difference between the groups: enlarged-head SEMS group, 87.1 days (range, 8–358 days versus uSEMS group, 60.4 days (range, 2–231 days (p=0.204. With enlarged-head SEMS, distal migration did not occur, but proximal migration was observed in four cases. Conclusions. Distal migration was prevented by shaping the SEMS to have an enlarged head, but improvement in stent patency could not be observed.

  15. Assessment of a Polyester-Covered Nitinol Stent in the Canine Aorta and Iliac Arteries

    International Nuclear Information System (INIS)

    Castaneda, Flavio; Ball-Kell, Susan M.; Young, Kate; Li Ruizong

    2000-01-01

    Purpose: To evaluate the patency and healing characteristics of a woven polyester fabric-covered stent in the canine model.Methods: Twenty-four self-expanding covered stents were placed in the infrarenal aorta and bilateral common iliac arteries of eight dogs and evaluated at 1 (n = 2), 3 (n = 2), and 6 (n = 4) months. Stent assessment was done using angiography prior to euthanasia, and light and scanning electron microscopy.Results: Angiographically, just prior to euthanasia, 8 of 8 aortic and 14 of 16 iliac endovascular covered stents were patent. Histologically, the stented regions showed complete endothelialization 6 months after graft implantation. A neointima had formed inside the stented vessel regions resulting in complete encasement of the fabric-covered stent by 3 months after graft implantation. Medial compression with smooth muscle cell atrophy was present in all stented regions. Explanted stent wires, examined by scanning electron microscopy, showed pitting but no cracks or breakage.Conclusion: The covered stent demonstrated predictable healing and is effective in preventing stenosis in vessels 10.0 mm or greater in diameter but does not completely preclude stenosis in vessels 6.0 mm or less in diameter

  16. Nasolacrimal Stenting: Toward Improving Outcomes with a Simple Modification of the Song Stent

    International Nuclear Information System (INIS)

    Lanciego, Carlos; Miguel, Silvia De; Padilla, Manuel; Perea, Miguel; Rodriguez-Merlo, Rufo; Garcia-Garcia, Lorenzo

    2006-01-01

    The purpose of this study was to evaluate, in a prospective, single-center study, the effectiveness of Song's polyurethane stents, modified 'in-house,' in the percutaneous management of epiphora. Patients (n = 170; age range 18-83, mean = 64; 50 male, 120 female) with severe epiphora had the modified stents inserted (183 eyes/195 stents) to treat unilateral/bilateral and complete/partial obstruction of the nasolacrimal system. The etiology of the obstruction was idiopathic in 119 cases (61%) and chronic dacryocystitis in 76 (39%). The set designed by Song was used in all patients but modified by us such that the extreme end is cone-shaped. The original technique was slightly modified by us and the procedure was conducted on an outpatient basis. The initial technical success rate of stent placement was 97%. Resolution of epiphora was complete in 180 eyes and partial in 3. On follow-up (mean = 18 months; range: 2 days to 24 months), 165 of 195 stents (85%) remained patent. Primary patency rates at follow-up were 86%, 84%, 84%, and 79% in the first 6 months, second and third 6 months, and the present (24 months), respectively. Stents became obstructed in 30 patients, but all but 2 were easily withdrawn and 20 of these patients remained asymptomatic for a mean of 14 months (secondary patency of 67%). Following stent removal, the withdrawn stent was replaced with a new stent in the same intervention on 14 occasions. In another six cases, patency was re-established without the need of a second stent. The procedure is simple and safe, both in stent insertion as well as in mechanical de-blocking and withdrawal when occluded. Success was >80 % in the short term (1-year follow-up). Stenting failure does not preclude other treatment because with the modification that we had introduced, the extreme end of the stent becomes more accessible to mechanical de-blocking, withdrawal, and relocation. The levels of primary and secondary patencies are promising and warrant more

  17. Comparison of Covered Versus Uncovered Stents for Benign Superior Vena Cava (SVC) Obstruction.

    Science.gov (United States)

    Haddad, Mustafa M; Simmons, Benjamin; McPhail, Ian R; Kalra, Manju; Neisen, Melissa J; Johnson, Matthew P; Stockland, Andrew H; Andrews, James C; Misra, Sanjay; Bjarnason, Haraldur

    2018-05-01

    To identify whether long-term symptom relief and stent patency vary with the use of covered versus uncovered stents for the treatment of benign SVC obstruction. We retrospectively identified all patients with benign SVC syndrome treated to stent placement between January 2003 and December 2015 (n = 59). Only cases with both clinical and imaging follow-up were included (n = 47). In 33 (70%) of the patients, the obstruction was due to a central line or pacemaker wires, and in 14 (30%), the cause was fibrosing mediastinitis. Covered stents were placed in 17 (36%) of the patients, and 30 (64%) patients had an uncovered stent. Clinical and treatment outcomes, complications, and the percent stenosis of each stent were evaluated. Technical success was achieved in all cases at first attempt. Average clinical and imaging follow-up in years was 2.7 (range 0.1-11.1) (covered) and 1.7 (range 0.2-10.5) (uncovered), respectively. There was a significant difference (p = 0.044) in the number of patients who reported a return of symptoms between the covered (5/17 or 29.4%) and uncovered (18/30 or 60%) groups. There was also a significant difference (p = stenosis after stent placement between the covered [17.9% (range 0-100) ± 26.2] and uncovered [48.3% (range 6.8-100) ± 33.5] groups. No significant difference (p = 0.227) was found in the time (days) between the date of the procedure and the date of clinical follow-up where a return of symptoms was reported [covered: 426.6 (range 28-1554) ± 633.9 and uncovered 778.1 (range 23-3851) ± 1066.8]. One patient in the uncovered group had non-endovascular surgical intervention (innominate to right atrial bypass), while none in the covered group required surgical intervention. One major complication (SIR grade C) occurred that consisted of a pericardial hemorrhagic effusion after angioplasty that required covered stent placement. There were no procedure-related deaths. Both covered and uncovered stents can be used for

  18. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Kondo, Hiromu; Yoshida, Michihiro; Shimizu, Shuya; Hirano, Atsuyuki; Okumura, Fumihiro; Ando, Tomoaki; Jinno, Naruomi; Takada, Hiroki; Togawa, Shozo; Joh, Takashi

    2018-03-01

    Endoscopic biliary and duodenal stenting (DS; double stenting) is widely accepted as a palliation therapy for malignant bilioduodenal obstruction. The aim of the current study was to investigate the patency and adverse events of duodenal and biliary stents in patients with DS. Patients who underwent DS from April 2004 to March 2017 were analyzed retrospectively with regard to clinical outcomes and predictive factors of recurrent biliary and duodenal obstruction (recurrent biliary obstruction [RBO] and recurrent duodenal obstruction [RDO]). A total of 109 consecutive patients was enrolled. Technical success of DS was achieved in 108 patients (99.1%). Symptoms due to biliary and duodenal obstruction were improved in 89 patients (81.7%). RBO occurred in 25 patients (22.9%) and RDO in 13 (11.9%). The median times to RBO and RDO from DS were 87 and 76 days, respectively. Placement of a duodenal uncovered self-expandable metal stent (U-SEMS) was significantly associated with RBO in the multivariable analysis (P = 0.007). Time to RBO was significantly longer in the duodenal covered self-expandable metal stent group than in the U-SEMS group (P = 0.003). No predictive factors of RDO were detected, and duodenal stent type was not associated with the time to RDO (P = 0.724). Double stenting was safe and effective for malignant bilioduodenal obstruction. Duodenal U-SEMS is a risk factor for RBO. The covered self-expandable metal stent is the preferred type of duodenal SEMS in patients with DS (Clinical trial registration number: UMIN000027606). © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  19. Covered versus uncovered self-expandable metal stents for malignant biliary strictures: A meta-analysis and systematic review.

    Science.gov (United States)

    Moole, Harsha; Bechtold, Matthew L; Cashman, Micheal; Volmar, Fritz H; Dhillon, Sonu; Forcione, David; Taneja, Deepak; Puli, Srinivas R

    2016-09-01

    Self-expandable metal stents (SEMS) are used for palliating inoperable malignant biliary strictures. It is unclear if covered metal stents are superior to uncovered metal stents in these patients. We compared clinical outcomes in patients with covered and uncovered stents. Studies using covered and uncovered metallic stents for palliation in patients with malignant biliary stricture were reviewed. Articles were searched in MEDLINE, PubMed, and Ovid journals. Fixed and random effects models were used to calculate the pooled proportions. Initial search identified 1436 reference articles, of which 132 were selected and reviewed. Thirteen studies (n = 2239) for covered and uncovered metallic stents which met the inclusion criteria were included in this analysis. Odds ratio for stent occlusion rates in covered vs. uncovered stents was 0.79 (95 % CI = 0.65 to 0.96). Survival benefit in patients with covered vs. uncovered stents showed the odds ratio to be 1.29 (95 % CI = 0.95 to 1.74). Pooled odds ratio for migration of covered vs. uncovered stents was 9.9 (95 % CI = 4.5 to 22.3). Covered stents seemed to have significantly lesser occlusion rates, increased odds of migration, and increased odds of pancreatitis compared to uncovered stents. There was no statistically significant difference in the survival benefit, overall adverse event rate, and patency period of covered vs. uncovered metal stents in patients with malignant biliary strictures.

  20. Esophageal carcinoma treatment with self-expanding covered stent implanted in esophagus

    International Nuclear Information System (INIS)

    Liu Mingguo; Ji Yan; He Nengwei

    2006-01-01

    Objective: To investigate the clinical significance of the treatment to esophageal cancer by self- expanding covered stent implanted into esophagus. Methods: Under fluoroscopic guidance and with guidance wire , 20 self-expanding covered stents were implanted into stenotic part of esophagus to recanalize the esophagus, then follow up to observe the clinical symptom improved. Results: Technical success was obtained 20 cases without any complication. Clinical symptom were improved in shot time. Conclusions: self-expanding covered stent is implanted in stenotic part of esophageal carcinoma to treat esophageal stenosis and enable to improved clinical symptom in shot time, if combined with transcatheter arterial infusion and embolization, Radiotherapy, Chinese medical treatment, it enable to lengthen life time remarkably. (authors)

  1. Outcomes of Prosthetic Hemodialysis Grafts after Deployment of Bare Metal versus Covered Stents at the Venous Anastomosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Charles Y., E-mail: charles.kim@duke.edu; Tandberg, Daniel J.; Rosenberg, Michael D.; Miller, Michael J.; Suhocki, Paul V.; Smith, Tony P. [Duke University Medical Center, Division of Vascular and Interventional Radiology (United States)

    2012-08-15

    Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metal stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.

  2. Outcomes of Prosthetic Hemodialysis Grafts after Deployment of Bare Metal versus Covered Stents at the Venous Anastomosis

    International Nuclear Information System (INIS)

    Kim, Charles Y.; Tandberg, Daniel J.; Rosenberg, Michael D.; Miller, Michael J.; Suhocki, Paul V.; Smith, Tony P.

    2012-01-01

    Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metal stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.

  3. [Complications and the management of fully covered retrievable metal stent placement in benign tracheal stenosis].

    Science.gov (United States)

    Wang, Zheng-yu; Wang, Yong-li; Chen, Guang-li; Liang, Xi-hong; Wang, Zhen-chang; Ma, Jian-zhong; Wu, Guang-zhong; Zhang, Xiao-ping

    2012-11-01

    To study complications and the management of the use of covered retrievable expandable metallic stents in the treatment of benign tracheal stenosis. Fully covered retrievable metal stents were placed in 21 patients with benign tracheal stenosis. Stent-related complications and the management were reviewed and analysed. Twenty-eight fully covered retrievable metallic stents were successfully placed fluoroscopically in 21 patients. Stents were removed 4 - 12 months [mean (5.5 ± 2.2) mouths] after placement in all patients. Stent-related complications included granulation tissue (n = 18), stent migration (n = 4), stent expectoration (n = 2), halitosis (n = 8), mucous retention (n = 21) and mucus plugging (n = 1). Granulation tissue was removed with a carbon dioxide laser in 2 patients. Stents were replaced for 2 times and 3 times respectively in 2 patients after stent migration and stent expectoration. An additional stent was placed in 2 patients after stent migration. Symptom of halitosis was relieved after prolonged course of systemic antibiotics treatment in 8 patients. Symptom of mucous retention was relieved with nebulized saline and N-acetylcysteine saline inhalation. Mucous plug was expelled after severe coughing after suctioning using an aspirator in one patient. There were statistically significant differences in stricture diameter, rank of tachypnea and pulmonary function (FEV(1)) in all 21 patients before stent insertion and after stents removal. No patient has experienced recurrence during the follow-up period of 1 - 36 months [mean (23.2 ± 8.0) months]. Fully covered retrievable metallic stent may be a safe and effective in benign tracheal stenosis. Stent-related complications may be effectively managed.

  4. Covered Metal Stenting for Malignant Lower Biliary Stricture with Pancreatic Duct Obstruction: Is Endoscopic Sphincterotomy Needed?

    Directory of Open Access Journals (Sweden)

    Kazunari Nakahara

    2013-01-01

    Full Text Available Aims. To evaluate the need for endoscopic sphincterotomy (EST before covered self-expandable metal stent (CSEMS deployment for malignant lower biliary stricture with pancreatic duct obstruction. Methods. This study included 79 patients who underwent CSEMS deployment for unresectable malignant lower biliary stricture with pancreatic duct obstruction. Treatment outcomes and complications were compared between 38 patients with EST before CSEMS deployment (EST group and 41 without EST (non-EST group. Results. The technical success rates were 100% in both the EST and the non-EST group. The incidence of pancreatitis was 2.6% in the EST, and 2.4% in the non-EST group (. The incidences of overall complications were 18.4% and 14.6%, respectively, (. Within the non-EST groups, the incidence of pancreatitis was 0% in patients with fully covered stent deployment and 3.6% in those with partially covered stent deployment (. In the multivariate analysis, younger age (, OR 12 and nonpancreatic cancer (, OR 24 were significant risk factors for overall complications after CSEMS deployment. EST was not identified as a risk factor. Conclusions. EST did not reduce the incidence of pancreatitis after CSEMS deployment in patients of unresectable distal malignant obstruction with pancreatic duct obstruction.

  5. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak; Han, Hyun Young

    2000-01-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  6. Use of covered self-expandable stents for benign colorectal disorders in children.

    Science.gov (United States)

    Lange, Bettina; Sold, Moritz; Kähler, Georg; Wessel, Lucas M; Kubiak, Rainer

    2017-01-01

    There is a lack of experience with covered self-expandable stents for benign colorectal disorders in children. Five children (4M, 1F) with a median age of 5years (range, 6months-9years) who underwent treatment with covered self-expandable plastic (SEPSs) or self-expandable metal stents (SEMSs) for a benign colorectal condition between April 2005 and November 2013 were recruited to this retrospective study. Etiologies included: anastomotic stricture with (n=1) or without (n=3) simultaneous enterocutaneous fistula, as well as an anastomotic leak associated with enterocutaneous fistula (n=1). All children suffered from either Hirschsprung's disease (n=3) or total colonic aganglionosis (Zuelzer-Wilson syndrome) (n=2). Median duration of individual stent placement was 23days (range, 1-87days). In all cases up to five different stents were placed over time. At follow-up two patients were successfully treated without further intervention. In another patient the anastomotic stricture resolved fully, but a coexisting enterocutaneous fistula persisted. Overall, three patients did not improve completely following stenting and required definite surgery. Stent-related problems were noted in all cases. There was one perforation of the colon at stent insertion. Further complications consisted of stent dislocation (n=4), obstruction (n=1), formation of granulation tissue (n=1), ulceration (n=1) and discomfort (n=3). Covered self-expandable stents enrich the armamentarium of interventions for benign colorectal disorders in children including anastomotic strictures and intestinal leaks. A stent can be applied either as an emergency procedure (bridge to surgery) or as an adjuvant treatment further to endoscopy and dilatation. Postinterventional problems are frequent but there is a potential for temporary or definite improvement following stent insertion. Copyright © 2017. Published by Elsevier Inc.

  7. Bile Duct Disruption Following Radiofrequency Ablation: Successful Repair Using a Covered Stent

    International Nuclear Information System (INIS)

    Thompson, Philip M.; Hare, Christopher M.B.; Lees, William R.

    2004-01-01

    Persistent biliary leaks, whether iatrogenic or secondary to malignancy, often present a difficult management problem. Recent reports have suggested a role for covered metallic stents in this context. We describe the successful use of a covered stent to seal a persistent biliary leak following radiofrequency ablation of colorectal liver metastases

  8. Treatment of cuff-related tracheal stenosis with a fully covered retrievable expandable metallic stent

    International Nuclear Information System (INIS)

    Chen, G.; Wang, Z.; Liang, X.; Wang, Y.; Wang, Y.; Wang, Z.; Xian, J.

    2013-01-01

    Aim: To investigate the clinical effectiveness, complications, and optimal duration of use of covered retrievable expandable metallic stents in the management of cuff-related tracheal stenosis. Materials and methods: Twenty-one patients with cuff-related tracheal stenosis, Meyer–Cotton grade II (29%) and III (71%), who underwent fluoroscopically guided placement of covered retrievable expandable metallic stents were studied. Sixty-four-section computed tomography (CT) and bronchovideoscopy were performed prior to stent insertion, 1 month after stent insertion, in the case of stent-related complications, and after stent removal. Clinical manifestations, Hugh–Jones classification, and forced expiratory volume in 1 s (FEV1) were used to evaluate respiratory function before and after stent insertion and removal. The diameter of the stricture and FEV1 changes before insertion and after removal were analysed using the paired samples t-test. A p-value of ≤0.05 was considered statistically significant. Results: Twenty-one patients had 27 covered retrievable expandable metallic stents placed. Stents were electively removed from 20 patients. The median duration of stent placement was 5 months (range 4–12 months). One stent was not removed due to mucopolysaccharidosis type II (MPS II or Hunter syndrome) with tracheomalacia. After stent removal, airway dimensions increased and airway occlusion was symptomatically relieved in all patients. CT and bronchovideoscopy showed patent lumens with increased dimensions. Stent-related complications occurred in 19 (91%) patients, including granulation tissue formation (n = 18, 86%), stent migration and stent expectoration (n = 2, 10%), mucus plugging (n = 1, 5%), and halitosis (n = 6, 29%). Some patients experienced multiple complications, which were all managed effectively while the stent was still in place. There was a statistically significant difference in the diameter of the stricture and FEV1 between the time of stent

  9. Treatment of cuff-related tracheal stenosis with a fully covered retrievable expandable metallic stent.

    Science.gov (United States)

    Chen, G; Wang, Z; Liang, X; Wang, Y; Wang, Y; Wang, Z; Xian, J

    2013-04-01

    To investigate the clinical effectiveness, complications, and optimal duration of use of covered retrievable expandable metallic stents in the management of cuff-related tracheal stenosis. Twenty-one patients with cuff-related tracheal stenosis, Meyer-Cotton grade II (29%) and III (71%), who underwent fluoroscopically guided placement of covered retrievable expandable metallic stents were studied. Sixty-four-section computed tomography (CT) and bronchovideoscopy were performed prior to stent insertion, 1 month after stent insertion, in the case of stent-related complications, and after stent removal. Clinical manifestations, Hugh-Jones classification, and forced expiratory volume in 1 s (FEV1) were used to evaluate respiratory function before and after stent insertion and removal. The diameter of the stricture and FEV1 changes before insertion and after removal were analysed using the paired samples t-test. A p-value of ≤0.05 was considered statistically significant. Twenty-one patients had 27 covered retrievable expandable metallic stents placed. Stents were electively removed from 20 patients. The median duration of stent placement was 5 months (range 4-12 months). One stent was not removed due to mucopolysaccharidosis type II (MPS II or Hunter syndrome) with tracheomalacia. After stent removal, airway dimensions increased and airway occlusion was symptomatically relieved in all patients. CT and bronchovideoscopy showed patent lumens with increased dimensions. Stent-related complications occurred in 19 (91%) patients, including granulation tissue formation (n = 18, 86%), stent migration and stent expectoration (n = 2, 10%), mucus plugging (n = 1, 5%), and halitosis (n = 6, 29%). Some patients experienced multiple complications, which were all managed effectively while the stent was still in place. There was a statistically significant difference in the diameter of the stricture and FEV1 between the time of stent insertion and removal. An improvement in

  10. Comparison of covered and uncovered self-expandable stents in the treatment of malignant biliary obstruction.

    Science.gov (United States)

    Flores Carmona, Diana Yamel; Alonso Lárraga, Juan Octavio; Hernández Guerrero, Angélica; Ramírez Solís, Mauro Eduardo

    2016-05-01

    Drainage with metallic stents is the treatment of choice in malignant obstructive jaundice. Technical and clinical success with metallic stents is obtained in over 90% and 80% of cases, respectively. There are self-expandable metallic stents designed to increase permeability. The aim of this study was to describe the results obtained with totally covered self-expandable and uncovered self-expandable metallic stents in the palliative treatment of malignant biliary obstruction. Sixty eight patients with malignant obstructive jaundice secondary to pancreatobiliary or metastatic disease not amenable to surgery were retrospectively included. Two groups were created: group A (covered self-expandable metallic stents) (n = 22) and group B (uncovered self-expandable metallic stents) (n = 46). Serum total bilirubin, direct bilirubin, alkaline phosphatase and gamma glutamyl transferase levels decreased in both groups and no statistically significant difference was detected (p = 0.800, p = 0.190, p = 0.743, p = 0.521). Migration was greater with covered stents but it was not statistically significant either (p = 0.101). Obstruction was greater in the group with uncovered stents but it was not statistically significant either (p = 0.476). There are no differences when using covered self-expandable stents or uncovered self-expandable stents in terms of technical and clinical success or complications in the palliative treatment of malignant obstructive jaundice.

  11. Long Term Follow-up of a Transjugular Intrahepatic Portosystemic Shunt: A Comparison of Covered and Uncovered Stents

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Seung Moon; Park, Jae Hyung; Kim, Hyo Cheol; Jae, Hwan Jun; Chung, Jin Wook [Seoul National University Hospital, Seoul (Korea, Republic of)

    2009-01-15

    To evaluate the long term patency of transjugular intrahepatic portosystemic shunts (TIPS) and to compare the patency rate of covered and uncovered stents in TIPS. The study population included 78 patients with portal hypertension that underwent TIPS between January 1999 and July 2007 at our institution using uncovered stents in 53 patients and covered stents in 25 patients. The primary and secondary patency rates of TIPS were estimated to compare the uncovered and covered stent groups. The primary and secondary patency rates of the TIPS patients were found to be 83.9% and 93.9% at the 6 month follow-up and 73.5% and 88.5% at the12 month follow-up for uncovered and covered stents, respectively. A breakdown patency rates for the 12 month follow-up revealed that the primary patency rates were 76.6% and 66.3% for uncovered and covered stents, respectively; whereas, the secondary patency rates were 94.3% and 73.8% for the uncovered and covered stents, respectively. A comparative analysis did not provide evidence to suggest that a difference exists between the patency rates of the uncovered and covered stent groups (p>0.05). No significant difference was found between the patency rates of the uncovered and covered stent groups. A follow-up to this study would be a more thorough randomized evaluation of the different types of covered stents to compare long-term patency rates.

  12. Percutaneous Palliation of Pancreatic Head Cancer: Randomized Comparison of ePTFE/FEP–Covered Versus Uncovered Nitinol Biliary Stents

    International Nuclear Information System (INIS)

    Krokidis, Miltiadis; Fanelli, Fabrizio; Orgera, Gianluigi; Tsetis, Dimitrios; Mouzas, Ioannis; Bezzi, Mario; Kouroumalis, Elias; Pasariello, Roberto; Hatzidakis, Adam

    2011-01-01

    The purpose of this study was to compare the clinical effectiveness of expanded polytetrafluoroethylene/fluorinated-ethylene-propylene (ePTFE/FEP)–covered stents with that of uncovered nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer. Eighty patients were enrolled in a prospective randomized study. Bare nitinol stents were used in half of the patients, and ePTFE/FEP–covered stents were used in the remaining patients. Patency, survival, complications, and mean cost were calculated in both groups. Mean patency was 166.0 ± 13.11 days for the bare-stent group and 234.0 ± 20.87 days for the covered-stent group (p = 0.007). Primary patency rates at 3, 6, and 12 months were 77.5, 69.8, and 69.8% for the bare-stent group and 97.5, 92.2, and 87.6% for the covered-stent group, respectively. Mean secondary patency was 123.7 ± 22.5 days for the bare-stent group and 130.3 ± 21.4 days for the covered-stent group. Tumour ingrowth occurred exclusively in the bare-stent group in 27.5% of cases (p = 0.002). Median survival was 203.2 ± 11.8 days for the bare-stent group and 247.0 ± 20 days for the covered-stent group (p = 0.06). Complications and mean cost were similar in both groups. Regarding primary patency and ingrowth rate, ePTFE/FEP–covered stents have shown to be significantly superior to bare nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer and pose comparable cost and complications. Use of a covered stent does not significantly influence overall survival rate; nevertheless, the covered endoprosthesis seems to offer result in fewer reinterventions and better quality of patient life.

  13. Elective implantation of covered stents for coarctation and recoarctation in adolescents and adults.

    Science.gov (United States)

    Alcibar, Juan; Blanco, Roberto; Fernandez, Luis; Arriola, Josune; Garcia, Koldobika; Peña, Natividad; Inguanzo, Ramón; Voces, Roberto; Castellanos, Enrique; Montes, Pedro M

    2013-06-01

    Stent implantation is an effective therapy for aortic coarctation and recoarctation. However, in adolescents and adults, aortic wall rupture and dissection can occur, as well as aneurysms during follow-up. In order to reduce these complications, we electively implant covered stents. Since 2005, we have performed the procedure using femoral access in 17 patients (2 adolescents and 15 adults), 16 electively and 1 as a rescue procedure. We used the Mullins technique in all cases, implanting a NuMED(®) covered stent. Good stent apposition was achieved in all 17 procedures; 8 patients required a distal flare. Gradient was reduced from 40 (16) mmHg to 2 (2) mmHg (P<.001) and lumen diameter increased from 4 (2) mm to 19 (3) mm (P<.001). Two exceptional cases are discussed: one patient with aortic wall rupture who underwent a rescue procedure using a stent within a covered stent and another patient with total obstruction and intercostal aneurysm in whom the outcome was fatal at 48 h postprocedure (autopsy is shown). Four-year clinical follow-up included Doppler echocardiography; an additional imaging technique was required in 13 patients. All patients recovered well and there were no complications. Covered stents are effective in treating coarctation and recoarctation in adolescents and adults, are the treatment of choice in patients with complex anatomy, and must be available in the operating room as a rescue device when implanting a conventional stent. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  14. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    International Nuclear Information System (INIS)

    Han, Young-Min; Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho

    2007-01-01

    We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates

  15. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young-Min; Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho [Chonbuk National University Medical School and Hospital, Chonju (Korea, Republic of)

    2007-10-15

    We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates.

  16. Polyethyleneimine brushes effectively inhibit encrustation on polyurethane ureteral stents both in dynamic bioreactor and in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Gultekinoglu, Merve [Department of Basic Pharmaceutical Sciences, Faculty of Pharmacy, Hacettepe University, Ankara 06100 (Turkey); Bioengineering Division, Institute for Graduate Studies in Science and Engineering, Hacettepe University, Ankara 06532 (Turkey); Kurum, Barış [Department of Surgery, Faculty of Veterinary Medicine, Kırıkkale University, Kırıkkale 71450 (Turkey); Karahan, Siyami [Department of Histology and Embryology, Faculty of Veterinary Medicine, Kırıkkale University, Kırıkkale 71450 (Turkey); Kart, Didem; Sagiroglu, Meral [Department of Pharmaceutical Microbiology, Faculty of Pharmacy, Hacettepe University, Ankara 06100 (Turkey); Ertaş, Nusret [Department of Analytical Chemistry, Faculty of Pharmacy, Gazi University, Ankara 06330 (Turkey); Haluk Ozen, A. [Department of Urology, Faculty of Medicine, Hacettepe University, Ankara 06100 (Turkey); Ulubayram, Kezban, E-mail: ukezban@hacettepe.edu.tr [Department of Basic Pharmaceutical Sciences, Faculty of Pharmacy, Hacettepe University, Ankara 06100 (Turkey); Bioengineering Division, Institute for Graduate Studies in Science and Engineering, Hacettepe University, Ankara 06532 (Turkey)

    2017-02-01

    Polyurethane (PU) ureteral stents have been widely used as biomedical devices to aid the flow of the urine. Due to the biofilm formation and encrustation complications it has been hindered their long term clinical usage. To overcome these complications, in this study, cationic polyethyleneimine (PEI) brushes grafted on PU stents and their performances were tested both in a dynamic biofilm reactor system (in vitro) and in a rat model (in vivo). Thus, we hypothesized that PEI brushes inhibit bacterial adhesion owing to the dynamic motion of brushes in liquid environment. In addition, cationic structure of PEI disrupts the membrane and so kills the bacteria on time of contact. Cationic PEI brushes decreased the biofilm formation up to 2 orders of magnitude and approximately 50% of encrustation amount in respect to unmodified PU, in vitro. In addition, according to Atomic Absorption Spectroscopy (AAS) results, approximately 90% of encrustation was inhibited on in vivo animal models. Decrease in encrustation was clearly observed on the stents obtained from rat model, by Scanning Electron Microscopy (SEM). Also, histological evaluations showed that; PEI brush grafting decreased host tissue inflammation in close relation to decrease in biofilm formation and encrustation. As a results; dual effect of anti-adhesive and contact-killing antibacterial strategy showed high efficiency on PEI brushes grafted PU stents both in vitro and in vivo.

  17. Polyethyleneimine brushes effectively inhibit encrustation on polyurethane ureteral stents both in dynamic bioreactor and in vivo

    International Nuclear Information System (INIS)

    Gultekinoglu, Merve; Kurum, Barış; Karahan, Siyami; Kart, Didem; Sagiroglu, Meral; Ertaş, Nusret; Haluk Ozen, A.; Ulubayram, Kezban

    2017-01-01

    Polyurethane (PU) ureteral stents have been widely used as biomedical devices to aid the flow of the urine. Due to the biofilm formation and encrustation complications it has been hindered their long term clinical usage. To overcome these complications, in this study, cationic polyethyleneimine (PEI) brushes grafted on PU stents and their performances were tested both in a dynamic biofilm reactor system (in vitro) and in a rat model (in vivo). Thus, we hypothesized that PEI brushes inhibit bacterial adhesion owing to the dynamic motion of brushes in liquid environment. In addition, cationic structure of PEI disrupts the membrane and so kills the bacteria on time of contact. Cationic PEI brushes decreased the biofilm formation up to 2 orders of magnitude and approximately 50% of encrustation amount in respect to unmodified PU, in vitro. In addition, according to Atomic Absorption Spectroscopy (AAS) results, approximately 90% of encrustation was inhibited on in vivo animal models. Decrease in encrustation was clearly observed on the stents obtained from rat model, by Scanning Electron Microscopy (SEM). Also, histological evaluations showed that; PEI brush grafting decreased host tissue inflammation in close relation to decrease in biofilm formation and encrustation. As a results; dual effect of anti-adhesive and contact-killing antibacterial strategy showed high efficiency on PEI brushes grafted PU stents both in vitro and in vivo.

  18. Endobronchial Occlusion Stent: A Preliminary Experimental Study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yo Won; Jeong, Woo Kyoung; Lee, Seoung Hoon; Heo, Jeong Nam; Jeon, Seok Chol [Hanyang University College of Medicine, Seoul (Korea, Republic of); Ko, Gi Young; Song, Ho Young [University of Ulsan College of Medicine, Ulsan (Korea, Republic of)

    2010-04-15

    To evaluate the safety and the technical feasibility of the use of an endobronchial occlusion stent and to get preliminary data for the development of the optimal material required for endobronchial occlusions. A commercialized, self-expandable tracheobronchial stent was modified; one half had a polyurethane cover with an occluded end and the other half was uncovered with a flaring configuration. The occluded end was placed such that it would face the distal lung. Under fluoroscopic guidance, seven stents were placed at the lower lobar bronchus in 6 mini-pigs. The bronchial obstruction was examined immediately after stent placement. Chest radiographs were taken at days 1, 7, 14, and 28 after stent placement and the removed airways from two, two, one, and one mini-pigs sacrificed on corresponding days were examined for the maintenance of bronchial obstruction. Stents were successfully placed and induced the immediate bronchial obstruction in all mini-pigs. Five of seven airways with occlusion stents maintained an obstruction until the mini-pigs were sacrificed. Proximal stent migration occurred in two mini-pigs (29%), and pulmonary consolidations were observed distal to four of the stents (57%). The placement of an endobronchial occlusion stent and the obstruction of targeted bronchi seem to be feasible, but an add-on check valve should be considered to prevent stent migration and obstructive pneumonia

  19. Polyorethaoe-covered nitinol strecker stents as primary palliative treatment of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Kanasaki, Shuzo; Furukawa, Akira; Kane, Teruyuki; Murata, Kiyoshi

    2000-01-01

    Purpose: To evaluate the clinical efficacy of the polyure-thane-covered Nitinol Strecker stent in the treatment of patients with malignant biliary obstruction.Methods: Twenty-three covered stents produced by us were placed in 18 patients with malignant biliary obstruction. Jaundice was caused by cholangiocarcinoma (n=5), pancreatic Cancer (n=6), gallbladder Cancer (n=4), metastatic lymph nodes (n=2), and tumor of the papilla (n=1).Resulrs: The mean patency period of the Stents was 37.5 weeks (5-106 weeks). Recurrent obstructive jaundice occurred in two patients (11%). Adequate biliary drainage over 50 weeks or until death was achieved in 17 of 18 patients (94.4%). Late cholangitis was observed in two patients whose stents bridged the ampulla of Vater. Other late severe complications were not encountered.Conclusion: Although more study is necessary, our results suggest the clinical efficacy of our covered Nitinol Strecker stent in the management of obstructive jaundice caused by malignant diseases.

  20. Treating mediastinoesophageal fistula with covered stent through nasal esophagus drainage tube

    International Nuclear Information System (INIS)

    Han Xinwei; Wu Gang; Li Yongdong; Ma Nan; Wang Yanli; Gao Xuemei

    2005-01-01

    Objective: To investigate the value of treating mediastinoesophageal fistula with covered stent through nasal esophagus drainage tube. Methods: Ten patients with mediastinoesophageal fistula were treated by 5F catheter inserting into the abscess cavities through nasal esophageal fistula, with stent placement in the esophagus. The abscess cavities were washed and angiograghied through drainage tube and the sites of the drainage tube were adjusted in time until withdrawal of the tube. Results: The drainage tubes were pulled out within 10-25 days with disappearance of the abscess cavities and normal diet intake without difficulty. Conclusions: Treating mediastinoesophageal fistula with covered stent through nasal esophagus drainage tube is safe, microinvasive economic and acceptable, worth to be recommended. (authors)

  1. Covered Biodegradable Stent: New Therapeutic Option for the Management of Esophageal Perforation or Anastomotic Leak

    International Nuclear Information System (INIS)

    Černá, Marie; Köcher, Martin; Válek, Vlastimil; Aujeský, René; Neoral, Čestmír; Andrašina, Tomáš; Pánek, Jiří; Mahathmakanthi, Shankari

    2011-01-01

    Purpose: This study was designed to evaluate our experience with the treatment of postoperative anastomotic leaks and benign esophageal perforations with covered biodegradable stents. Materials and Methods: From 2008 to 2010, we treated five men with either an anastomotic leak or benign esophageal perforation by implanting of covered biodegradable Ella-BD stents. The average age of the patients was 60 (range, 38–74) years. Postoperative anastomotic leaks were treated in four patients (1 after esophagectomy, 1 after resection of diverticulum, 2 after gastrectomy). In one patient, perforation occurred as a complication of the treatment of an esophageal rupture (which occurred during a balloon dilatation of benign stenosis) with a metallic stent. Results: Seven covered biodegradable stents were implanted in five patients. Primary technical success was 100%. Clinical success (leak sealing) was achieved in four of the five patients (80%). Stent migration occurred in three patients. In two of these patients, the leak had been sealed by the time of stent migration, therefore no reintervention was necessary. In one patient an additional stent had to be implanted. Conclusion: The use of biodegradable covered stents for the treatment of anastomotic leaks or esophageal perforations is technically feasible and safe. The initial results are promising; however, larger number of patients will be required to evaluate the capability of these biodegradable stents in the future. The use of biodegradable material for coverage of the stent is essential.

  2. Successful Exclusion of a Large Femoropopliteal Aneurysm with a Covered Nitinol Stent

    International Nuclear Information System (INIS)

    Dorffner, Roland; Winkelbauer, Friedrich; Kettenbach, Joachim; Staudacher, Michael; Lammer, Johannes

    1996-01-01

    A 70-year-old woman presented with a large femoropopliteal aneurysm. A covered nitinol stent was implanted successfully and complete exclusion of the aneurysm was achieved. At follow-up 5 months later the stent was still patent and the patient was free of symptoms. However, moderate stenosis was seen at the proximal end of the stent

  3. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    International Nuclear Information System (INIS)

    Huet, Nicolas; Rodiere, Mathieu; Badet, Michel; Michoud, Marie; Brichon, Pierre-Yves; Ferretti, Gilbert; Thony, Frédéric

    2016-01-01

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  4. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    Energy Technology Data Exchange (ETDEWEB)

    Huet, Nicolas, E-mail: nhuet@chu-grenoble.fr; Rodiere, Mathieu, E-mail: mrodiere@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France); Badet, Michel, E-mail: michel.badet@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, site de Chambéry, Intensive Care Unit (France); Michoud, Marie, E-mail: marie.michoud@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, Site de Chambéry, Department of Radiology (France); Brichon, Pierre-Yves, E-mail: pybrichon@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Thoracic and Vascular Surgery (France); Ferretti, Gilbert, E-mail: gferretti@chu-grenoble.fr; Thony, Frédéric, E-mail: fthony@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France)

    2016-05-15

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  5. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-10-01

    Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).

  6. Outcomes of endoscopically inserted self-expandable metal stents in malignancy according to the type of stent and the site of obstruction.

    Science.gov (United States)

    Jung, Kyoungwon; Ahn, Ji Yong; Jung, Hwoon-Yong; Cho, Charles J; Na, Hee Kyong; Jung, Kee Wook; Lee, Jeong Hoon; Kim, Do Hoon; Choi, Kee Don; Song, Ho June; Lee, Gin Hyug; Kim, Jin-Ho

    2016-09-01

    Self-expandable metal stents (SEMSs) can be used for the palliation of malignant obstruction in the upper gastrointestinal tract. This study assessed the feasibility and efficacy of endoscopically inserted SEMSs for the palliation of malignant obstruction in the stomach and duodenum. Between January 2011 and April 2014, 220 patients with gastric or duodenal obstruction due to malignancy underwent endoscopic SEMS insertion at Asan Medical Center. The associations of technical/clinical outcomes and complications with the type of stent and site of obstruction were analyzed. The 220 patients included 125 men (56.8 %) and 95 women (43.2 %); median patient age was 63 years. Fully covered, partially covered, and uncovered SEMSs were inserted into 16, 77, and 120 patients, respectively. Obstructions were located in the gastric outlet, including the duodenal bulb, in 106 patients, and in the duodenal second and third portions in 114 patients. Technical success was achieved in 213 of 220 patients (96.8 %) and clinical success in 184 of 213 (86.4 %). Clinical success rates were similar to the type of stent, but were significantly greater for gastric outlet (95/104, 91.3 %) than for duodenal (89/109, 81.7 %) obstructions (p = 0.039). Stent migration was observed in 20 patients (9.1 %) and stent obstruction in 51 (23.2 %). Rates of stent migration were significantly higher for fully covered (6/16, 37.5 %) than for partially covered (7/77, 9.1 %) and uncovered (7/120, 5.8 %) SEMSs (p stent obstruction were similar for fully covered (2/16, 12.5 %), partially covered (17/77, 22.1 %), and uncovered (32/120, 26.7 %) SEMSs (p = 0.409) and in patients with gastric outlet (26/104, 25.0 %) and duodenal (25/109, 22.9 %) obstruction (p = 0.724). SEMS selection for malignant obstruction of the upper gastrointestinal tract depends on the site of obstruction.

  7. Development of radioactive stent using HANARO research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Bae; Kim, J. R.; Han, H. S.; Shin, B. C.; Kim, Y. M.; Cho, U. K.; Han, K. H.; Park, W. W.; Chung, Y. J

    1997-10-01

    Radioactive cylindrical was prepared by neutron irradiation of pre-made non-radioactive `1`6`5 Ho-sleeve, which was made by casting polyurethane solution containing `1`6`5`Ho(NO{sub 3}){sub 3} in THF+DMF (10:1) solvent in cylindrical glass tube. Its length and diameter could be easily controlled by glass tube used as a mold. The radioactive stent assembly (`1`6`5Ho-SA) was prepared by covering the metallic stent with radioactive sleeve and then treated both ends with epoxy glue for prevention of peeling off the radioactive sleeve from stent (post-irradiation method). Other preparation method of radioactive stent is similar to that of the first one except using radioactive `1`6`6Ho(NO{sub 3}){sub 3} and glass tube fitted with metallic stent before casting (pre-irradiation method). Scanning electron microscopy and autoradiography exhibited that the distribution of `1`6`5Ho and `1`6`6Ho(NO{sub 3}) compounds in polyurethane matrix was nearly homogeneous. The present preparation methods of radioactive sleeve and stent are quite different from conventional method which metallic stent is coated or implanted with radionuclide. The ease with which the radioactive stent can be prepared and its homogeneous radiation emission make it an attractive radiation applicator for the treatment of esophagus cancer. As an animal studies, 6 pathologic specimens were obtained. An animal with 4 mCi of `1`6`6Ho-SA showed loss of epithelial tissue and inflammation at the submucosal layer 4 weeks after the procedure. Considerable improvement of the inflammatory reaction was observed 7 weeks post-therapy without complication. In case treated with 6 mCi of `1`6`6Ho-SA, tissue destruction and widening of the esophageal lumen were observed and the inflammatory reaction propagated into the muscle layer. In case with 9 mCi of `1`6`6Ho-SA, severe esophagitis with cellular proliferation were seen, which resulted in further narrowing of the lumen. (author). 58 refs., 5 tabs., 14 figs

  8. Development of radioactive stent using HANARO research reactor

    International Nuclear Information System (INIS)

    Park, Kyung Bae; Kim, J. R.; Han, H. S.; Shin, B. C.; Kim, Y. M.; Cho, U. K.; Han, K. H.; Park, W. W.; Chung, Y. J.

    1997-10-01

    Radioactive cylindrical was prepared by neutron irradiation of pre-made non-radioactive '1'6'5 Ho-sleeve, which was made by casting polyurethane solution containing '1'6'5'Ho(NO 3 ) 3 in THF+DMF (10:1) solvent in cylindrical glass tube. Its length and diameter could be easily controlled by glass tube used as a mold. The radioactive stent assembly ('1'6'5Ho-SA) was prepared by covering the metallic stent with radioactive sleeve and then treated both ends with epoxy glue for prevention of peeling off the radioactive sleeve from stent (post-irradiation method). Other preparation method of radioactive stent is similar to that of the first one except using radioactive '1'6'6Ho(NO 3 ) 3 and glass tube fitted with metallic stent before casting (pre-irradiation method). Scanning electron microscopy and autoradiography exhibited that the distribution of '1'6'5Ho and '1'6'6Ho(NO 3 ) compounds in polyurethane matrix was nearly homogeneous. The present preparation methods of radioactive sleeve and stent are quite different from conventional method which metallic stent is coated or implanted with radionuclide. The ease with which the radioactive stent can be prepared and its homogeneous radiation emission make it an attractive radiation applicator for the treatment of esophagus cancer. As an animal studies, 6 pathologic specimens were obtained. An animal with 4 mCi of '1'6'6Ho-SA showed loss of epithelial tissue and inflammation at the submucosal layer 4 weeks after the procedure. Considerable improvement of the inflammatory reaction was observed 7 weeks post-therapy without complication. In case treated with 6 mCi of '1'6'6Ho-SA, tissue destruction and widening of the esophageal lumen were observed and the inflammatory reaction propagated into the muscle layer. In case with 9 mCi of '1'6'6Ho-SA, severe esophagitis with cellular proliferation were seen, which resulted in further narrowing of the lumen. (author). 58 refs., 5 tabs., 14 figs

  9. Successful stent-in-stent insertion of an expandable metallic stent covered with polyuretane placed to obliterate a large bronchial fistula after chemoradiotherapy for inoperable lung cancer

    International Nuclear Information System (INIS)

    Minami, Hiroya; Tsubota, Noriaki; Miyamoto, Yoshifumi; Yoshimura, Masahiro; Obayashi, Kayoko; Takada, Yoshiki

    1999-01-01

    Bronchial fistulas in cases of inoperable lung cancer caused by radiochemotherapy are quite refractory and generally cannot be surgically closed. A 45-year-old man with squamous cell carcinoma in the right lung underwent two courses of induction chemotherapy (135 mg CDDP, 5 mg VDS, 13.5 mg MMC) and radiation therapy (2 Gy x 22 times) for invasion of the right main bronchus, the pulmonary artery and superior vena cava. Just before the end of the second course, the empyem second to the bronchial fistula caused by tumor necrosis developed in the right upper bronchus, and fenestration was performed. After the operation, his condition improved remarkably, however the fistula enlarged into the right main bronchus and the purulent discharge flowed into the left lung. An expandable metallic stent (EMS) covered with polyuretane was inserted in the trachea and the left main bronchus to break aspiration pneumonia. As the covered EMS was too unstable to be fixed, a bare EMS was inserted in a stent-in-stent fashion. After the procedure he was followed at the O.P.D. and lived a relatively comfortable life for 9 months until his death due to tumor. We inserted the covered EMS in a stent-in-stent fashion to successfully obliterate a large bronchial fistula. (author)

  10. Preliminary clinical application in the cranial internal carotid artery of covered stents specially designed for intracranial vasculature

    International Nuclear Information System (INIS)

    Li Minghua; Luo Qiyi; Fang Chun; Xie Zhiyong; Cheng Yingsheng; Gao Bulang; Li Yu; Zhang Beilei; Xie Jian; Wang Yongli

    2007-01-01

    Objective: To investigate the flexibility of both the covered stents specially designed for use in intracranial vasculature and the delivering system in passing through the bone tube and the physiological curves of the cranial internal carotid artery (CICA) to reach the targeted area, the performance (adherence) of the covered stents in occluding vascular wall diseases and the impact on the vascular branches of the covered segment. Methods: The covered stents specially designed for use in intracranial vasculature were used to treat 13 patients with CICA diseases using endovascular techniques. There were 4 huge pseudoaneurysms, 4 giant aneurysms, 3 small wide-necked aneurysms, 1 giant pseudoaneurysm with concurrent internal carotid cavernous fistula (CCF), and 1 CCF. Prior to the detachment of the covered stents, balloon occlusion test (BOT) of the internal carotid artery on the diseased side and whole-brain digital subtraction angiography (DSA) were performed in all the patients. Three to 16 months following procedure, DSA and clinical follow-ups were performed. Results: Thirteen patients all tolerated the BOT well with the DSA demonstrating well-opened anterior and posterior communicating arteries. The covered stents and the delivering systems all successfully passed CICA to reach the targeted diseased area, with the diseased segments of the internal carotid artery including C3-C4 in 4 cases, C4-C5 in 4 and C6-C7 in 5. Immediately following the detachment of the covered stents, DSA demonstrated that 7 aneurysms were completely occluded, 4 aneurysms had slight endoleak, and 1 CCF had markedly-decreased blood flow through the fistula. In the patient with concurrent pseudoaneurysm and CCF, the pseudoaneurysm disappeared and the blood flow through the fistula was markedly-reduced immediately following the stenting procedure. Apart from one patient with aneurysmal subarachnoid hemorrhage who died due to extensive vascular spasm on the 9th day following the stenting

  11. Optimal Covering Material for Stent-Grafts Placed in the Portal Vein in a Canine Model

    International Nuclear Information System (INIS)

    Ishii, Seigo; Sato, Morio; Sonomura, Tetsuo; Yamada, Katsuyuki; Tanihata, Hirohiko; Ishikawa, Hime; Terada, Masaki; Sahara, Shinya; Kawai, Nobuyuki; Kimura, Masashi; Mori, Ichiro

    2005-01-01

    Purpose. We evaluated the suitability of Dacron, polytetrafluoroethylene (PTFE), and small intestinal submucosa (SIS) as a covering material for stent-grafts placed in the portal vein as compared with a bare stent. Methods. Using 24 beagle dogs, either bare stents or stent-grafts covered with Dacron, PTFE, or SIS were placed in the main trunk of the portal vein in 6 animals each. Portography was performed immediately after stent placement, and at 2, 4, and 12 weeks thereafter. Next, the extracted stents or stent-grafts were examined histopathologically. Neointimal thickness adjacent to the stent wire and at the midportion between the stent wires was compared among the groups. Then, the neointimal thickness at the sub- and supragraft sites was compared between each stent-graft group. Serial changes in the histologic features of the thickened neointima were also investigated. Results. No significant difference was noted in the mean stenotic ratio of the portal vein diameter between the bare stent and PTFE groups, whereas it was significantly higher in the Dacron and SIS groups compared with the bare stent group. In neither of the studies on neointimal thickness adjacent to the stent wire and at the midportion between the stent wires were any significant differences noted between the neointimal thickness of the bare stent group and the sum of the neointimal thickness of the PTFE group, whereas the sum of the neointimal thickness of the Dacron and SIS groups was significantly greater than that of the bare stent group at both sites. In the comparison of the supragraft neointimal thickness, the SIS group showed significantly greater thickness than the PTFE group, while the difference between the Dacron and PTFE groups was not significant. In the comparison of the subgraft neointimal thickness, the Dacron and SIS groups showed significantly greater thickness than the PTFE group. Conclusion. The present results indicate that of the three covering materials examined here

  12. A Fast Placement Technique for Covered Tracheobronchial Stents in Patients with Complicated Esophagorespiratory Fistulas

    International Nuclear Information System (INIS)

    Kishi, Kazushi; Nakao, Taisei; Goto, Hironobu; Kimura, Masashi; Sonomura, Tetsuo; Yamanaka, Noboru; Nanjo, Kishio; Sato, Morio

    2005-01-01

    Purpose. To test an endotracheal placement procedure for malignant esophagorespiratory fistula when endoesophageal placement is inapplicable. Methods. We report on patients with malignant esophagorespiratory fistula to which endoesophageal approaches were complicated with a complete obstruction of the hypopharynx, a collapsible tracheobronchus, or a previously placed endoesophageal stents. Gore-Tex membrane-covered Z-stents were deployed in the trachea using a coaxial introducer system in three patients. A Dumon tube was deployed in the bronchus over the bronchofiberscope in one patient. Results. All fistula were completely sealed by the endotracheal or endobronchial stenting. Symptomatic and clinical improvements were immediate obtained. Conclusion. Endotracheal or endobronchial covered stent placement is thought to be an effective alternative method for sealing esophagorespiratory fistula

  13. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution

    Science.gov (United States)

    Coté, Gregory A.; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K.; Elmunzer, B. Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D.; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart

    2017-01-01

    IMPORTANCE Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. OBJECTIVE To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. DESIGN, SETTING, AND PARTICIPANTS Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. INTERVENTIONS Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. MAIN OUTCOMES AND MEASURES Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of −15%. RESULTS There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, −3.0% to ∞; P stents was rejected. The mean number of ERCPs to achieve resolution

  14. Palliation of Postoperative Gastrointestinal Anastomotic Malignant Strictures with Flexible Covered Metallic Stents: Preliminary Results

    International Nuclear Information System (INIS)

    Lee, Jeong-Min; Han, Young Min; Lee, Sang Yong; Kim, Chong Soo; Yang, Doo Hyun; Lee, Seung Ok

    2001-01-01

    Purpose: To evaluate the efficacy of the placement of covered metallic stents for palliation of gastrointestinal anastomotic strictures secondary to recurrent gastric cancer.Methods: Under fluoroscopic guidance, placement of one or two self-expandable covered metallic stents was attempted perorally in 11 patents (aged 48-76 years) with anastomotic stenoses due to recurrent gastric malignancies. The strictures involved both the afferent and efferent loops in three patients. All patients had poor peroral food intake with severe nausea and vomiting after ingestion. The technical and clinical success was evaluated.Results: Placement of the covered stent was technically successful in 13 of 15 (87%) attempts in ten patients. After the procedure, 9 of 11 (82%) patients overall were able to ingest at least a liquid diet and had markedly decreased incidence of vomiting. During the follow-up of 2-31 weeks (mean 8.5 weeks) there were no major complications.Conclusion: These preliminary results suggest that flexible, covered stents may provide effective palliation of malignant anastomotic stricture secondary to recurrent gastric cancer

  15. Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    Rössle M

    2018-01-01

    Full Text Available The availability of polytetrafluoroethylene (PTFE covered, self-expandable nitinol stents in 2001 considerably improved the patency, response rates and survival of the transjugular intrahepatic portosystemic shunt (TIPS. Side effects of portosystemic shunting such as hepatic encephalopathy (HE and worsening of hepatic function, however, remained a problem. To reduce HE, underdilatation of nitinol stents has been practiced for many years. However, as shown recently, underdilatation was a flop since, due to their intrinsic memory, nitinol stents always expanded to reach their nominal diameter of 8 or 10 mm. To overcome this problem and to be able to perform permanent shunts with a smaller diameter of < 8 mm, we studied the usefulness of a balloon-expandable, covered, metallic stent which allowed adjustment to any diameter between 5 and 12 mm. Methods: 30 patients with cirrhosis and symptomatic portal hypertension were included. The mean Child-Pugh score was 8 ± 2.17 patients had refractory ascites, 9 patients variceal bleeding and four patients other indications for the TIPS. Results: The TIPS was successfully implanted in all patients within 69.6 ± 21.8 min. The shunt reduced the portosystemic pressure gradient by 57.5 ± 14.2% with a mean stent diameter of 7.4 ± 1.0 mm (5 -10.3 mm. During a mean follow-up of 330 ± 249 days, shunt revision was necessary in 5 patients (17%, four of them had insufficient response and received stent dilatation and one patient had stent misplacement requiring a parallel shunt. Three patients (10% developed HE. Conclusions: The covered, balloon-expandable stent could be placed accurately and allowed creation of adapted shunts with smaller diameters as usual. This resulted in a comparatively low rate of HE.

  16. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of Medicine, Masan (Korea, Republic of)

    2008-06-15

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction.

  17. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon; Ko, Ji Ho

    2008-01-01

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction

  18. Conformable covered versus uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction: a randomized prospective study.

    Science.gov (United States)

    Lim, Sun Gyo; Kim, Jin Hong; Lee, Kee Myung; Shin, Sung Jae; Kim, Chan Gyoo; Kim, Kyung Ho; Kim, Ho Gak; Yang, Chang Heon

    2014-07-01

    A conformable self-expandable metallic stent was developed to overcome the limitation of previous self-expandable metallic stents. The aim of this study was to evaluate outcomes after placement of conformable covered and uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction. A single-blind, randomized, parallel-group, prospective study were conducted in 4 medical centres between March 2009 and July 2012. 134 patients with unresectable malignant gastroduodenal obstruction were assigned to a covered double-layered (n=66) or uncovered unfixed-cell braided (n=68) stent placement group. Primary analysis was performed to compare re-intervention rates between two groups. 120 patients were analysed (59 in the covered group and 61 in the uncovered group). Overall rates of re-intervention were not significantly different between the two groups: 13/59 (22.0%) in the covered group vs. 13/61 (21.3%) in the uncovered group, p=0.999. Stent migration was more frequent in the covered group than in the uncovered group (p=0.003). The tumour ingrowth rate was higher in the uncovered group than in the covered group (p=0.016). The rates of re-intervention did not significantly differ between the two stents. Conformable covered double-layered and uncovered unfixed-cell braided stents were associated with different patterns of stent malfunction. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  19. cancerous esophagotracheal fistula: treatment of placement with covered self-expanding metallic stent

    International Nuclear Information System (INIS)

    Han Xinwei; Li Tianxiao; Wang Ruilin; Fan Qingxia

    1997-01-01

    Purpose: To treat the esophagotracheal fistula that was the main cause of death in patients with esophageal carcinoma, the placement of the stent was studied. Materials and methods: Under the fluoroscopic guidance, 28 stents (5 stents made in USA and 23 in China) were successfully implanted in all the 28 patients with esophagotracheal fistula. Results: The aphagia of the patients was greatly improved and a normal diet could be swallowed at once after the placement of the stents. The 27 cases of inhalation pneumonia that caused by the fistula was recovered. Conclusion: The result indicated that the treatment with the placement of the covered self-expanding stent is simple, safe, and effective for most patients with aphagia and pneumonia due to esophagotracheal fistula

  20. Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

    Directory of Open Access Journals (Sweden)

    Ahmed Abdel Samie

    2012-01-01

    Full Text Available Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES, and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause.

  1. Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

    Science.gov (United States)

    Abdel Samie, Ahmed; Theilmann, Lorenz

    2012-01-01

    Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs) have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES), and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause. PMID:22761543

  2. Covered metal stent or multiple plastic stents for refractory pancreatic ductal strictures in chronic pancreatitis: a systematic review.

    Science.gov (United States)

    Shen, Yonghua; Liu, Mingdong; Chen, Min; Li, Yunhong; Lu, Ying; Zou, Xiaoping

    2014-01-01

    Refractory chronic pancreatitis has been proposed as a challenge for endoscopists following routine single plastic stenting. However, data on the efficacy and safety of further endoscopic stenting are still controversial. The current systematic review aimed to assess the efficacy and safety of placement of fully covered self-expandable metal stent (FCSEMS) and multiple plastic stents. Databases including MEDLINE, EMBASE, the Cochrane Library, CBM, CNKI, VIP, and WANFANG Database were used to search relevant trials. Published studies were assessed by using well-defined inclusion and exclusion criteria. The process was independently performed by two investigators. A total of 5 studies provided data of 80 patients. Forest plots and publication bias were not carried out because few studies were relevant and screened studies were all case series. The technical success rate was 100% both in placement of FCSEMS and multiple plastic stents. The functional success rate after placement of FCSEMS was 100%, followed by multiple plastic stents (94.7%). Complications occurred 26.2% after FCSEMS placement, which was not described in detail in multiple plastic stents. The stent migration rate was 8.2% for FCSEMS and 10.5% for multiple plastic stents. Reintervention rate was 9.8% for FCSEMS and 15.8% for multiple plastic stents. Pain improvement rate was 85.2% for FCSEMS and 84.2% for multiple plastic stents. FCSEMS appeared to be no significant difference with multiple plastic stents in treatment of refractory chronic pancreatitis. We need to develop more investigations. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  3. Case report: ruptured aortic aneurysm into oesophagus - treatment by covered stent

    International Nuclear Information System (INIS)

    Young, N.; Tan, I.; Costa, R.

    2002-01-01

    Full text: A case report of a 70 year old man acutely presenting with a large descending thoracic aortic aneurysm, ruptured into the adjacent oesophagus. He was treated with an Aneurex covered stent (Medtronics). This patient has a long history of ischaemic heart disease, hypertension and previously treated abdominal aortic aneurysm. After diagnosis by CT, the bleeding was emergency temponaded by insertion of a Sengstaken-Blackmore tube into the oesophagus and inflated to arterial pressure. After stabilisation in ICU, it was decided that open surgery would probably prove fatal, and insertion of a covered thoracic aortic stent was performed in theatre with a femoral artery cut-down. Post-operatively the bleeding from the aortic aneurysm ceased. However, the patient has ongoing problems with large, open oesophageal ulcer with chronic ooze requiring intermittent transfusions, chronic infection with MRSA, requiring long term antibiotics, feeding via feeding gastrostomy tubes. The patient is stable 12 months after presentation. Treatment of this otherwise fatal problem by covered stent has permitted survival benefit. However, there are significant, unresolved issues of oesophageal ulcer and ongoing MRSA infection. Copyright (2002) Blackwell Science Pty Ltd

  4. The design of trachea-main bronchial covered embranchment stent and the primary clinical application

    International Nuclear Information System (INIS)

    Han Xinwei; Wu Gang; Gao Xuemei; Li Yongdong; Wang Yanli; Ma Nan

    2004-01-01

    Objective: To design the trachea-main bronchus covered embranchment stent and study the primary treatment for thoracostomach main bronchial fistula and main bronchial stenosis. Methods: The stent was designed on the bases of the peculiar anatomic structure and the pathological changes of thoracostomach-main bronchial fistula and main bronchial stenosis. Under the fluoroscopic guidance, implantations were carried out in thoracostomach-carina fistula 1 case thoracostomach-left main bronchial fistula 1, thoracostomach-right main bronchial fistula and left main bronchial stenosis 1 case, altogether with 5 stents. Results: Stents were placed successfully, not only improving the breathing and living quality but also completing the closure of the ora of the thoracostomach-airway fistula with further vanishing of the choke after drinking and eating together with the inhalation pneumonia. The bronchus became normal in a main bronchial stenosis after the stent was taken out. Conclusions: Trachea-main bronchial covered embranchment stent could be used to close thoracostomach-airway fistula and to treat main bronchial benign/malignant stenosis. The procedure is simple and safe. (authors)

  5. Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease.

    Science.gov (United States)

    Groot Jebbink, Erik; Mathai, Varghese; Boersen, Johannes T; Sun, Chao; Slump, Cornelis H; Goverde, Peter C J M; Versluis, Michel; Reijnen, Michel M P J

    2017-07-01

    Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry seems to affect patency. These variations may affect local flow patterns, resulting in different wall shear stress (WSS) and oscillating shear index (OSI). The aim of this study was to compare the effect of different stent configurations on flow perturbations (recirculation and fluid stasis), WSS, and OSI in an in vitro setup. Three different stent configurations were deployed in transparent silicone models: bare-metal kissing (BMK) stents, covered kissing (CK) stents, and the covered endovascular reconstruction of the aortic bifurcation (CERAB) configuration. Transparent covered stents were created with polyurethane to enable visualization. Models were placed in a circulation setup under physiologic flow conditions. Time-resolved laser particle image velocimetry techniques were used to quantify the flow, and WSS and OSI were calculated. The BMK configuration did not show flow disturbances at the inflow section, and WSS values were similar to the control. An area of persistent low flow was observed throughout the cardiac cycle in the area between the anatomic bifurcation and neobifurcation. The CK model showed recirculation zones near the inflow area of the stents with a resulting low average WSS value and high OSI. The proximal inflow of the CERAB configuration did not show flow disturbances, and WSS values were comparable to control. Near the inflow of the limbs, a minor zone of recirculation was observed without changes in WSS values. Flow, WSS, and OSI on the lateral wall of the proximal iliac artery were undisturbed in all models. The studied aortoiliac stent configurations have distinct locations where flow disturbances occur, and these are related to the radial mismatch

  6. Evaluation of anti-migration properties of biliary covered self-expandable metal stents.

    Science.gov (United States)

    Minaga, Kosuke; Kitano, Masayuki; Imai, Hajime; Harwani, Yogesh; Yamao, Kentaro; Kamata, Ken; Miyata, Takeshi; Omoto, Shunsuke; Kadosaka, Kumpei; Sakurai, Toshiharu; Nishida, Naoshi; Kudo, Masatoshi

    2016-08-14

    To assess anti-migration potential of six biliary covered self-expandable metal stents (C-SEMSs) by using a newly designed phantom model. In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration (RFM) was measured by a force gauge on the stent end. Radial force (RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare (ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model. Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables (ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state. RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration.

  7. A newly designed Y-shaped covered stent in the palliative treatment of hepatic hilar malignant obstruction: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Chul; Lee, So Won [Dept. of Radiology, Mokdong Hospital, Ewha Womans University College of Medicine, Seoul (Korea, Republic of); Chung, Hwan Hoon [Dept. of Radiology, Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2013-01-15

    We report a case in an inoperable patient with the hilar malignant biliary obstruction treated palliatively by the use of a newly designed Y-shaped covered stent without interfering contra-lateral bile duct. We percutaneously inserted a newly designed Y-shaped covered stent into a biliary tree in an inoperable patient with Bismuth Type II cholangiocarcinoma. We checked tubograms, enhanced CT studies, and blood bilirubin levels before, one week after, and at every three month after the stenting, by observing closely the signs of clinical infection as well. The follow-up period was about 12 months. The placement of the Y-shaped covered stent was successful and resulted in adequate biliary drainage in the immediate post-procedural tubogram and in the follow-up abdominal CT. The serum bilirubin levels did not show elevation after the insertion of the Y-shaped covered stent.

  8. Utility of Covered Stents for Revision of Aging Failing Synthetic Hemodialysis Grafts: A Report of Three Cases

    International Nuclear Information System (INIS)

    Silas, Anne M.; Bettmann, Michael A.

    2003-01-01

    Three aging failing hemodialysis polytetrafluoroethylene bypass shunts, average age 44 months, previously percutaneously revised with balloon angioplasty, presented with pseudoaneurysms and recurrent thrombosis. All were treated with percutaneous covered stent placement within their affected limbs. One graft was ligated 1 month after treatment for infected overlying skin ulcer, though this graft was subsequently surgically revised with interposition graft and the covered stent portion remains functional at 19 month follow-up. The 18- and 13- month follow- up of the remaining 2 patients shows that the covered stents remained patent and they are functional and being successfully and routinely punctured for dialysis. In this elderly population, the use of covered stents may prolong the functional life of failing hemodialysis bypass grafts, reducing the number of percutaneous and surgical interventions and further sparing other vascular access sites

  9. Anchoring barbs and balloon expandable stents: what is the risk of perforation and failed stent deployment?

    Science.gov (United States)

    Bown, M J; Harrison, G J; How, T V; Brennan, J A; Fisher, R K; Vallabhaneni, S R; McWilliams, R G

    2012-09-01

    Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Benjamin Bondue

    2016-01-01

    Full Text Available Endoscopic treatment of a bronchial restenosis previously treated by insertion of a partially covered self-expandable metallic stent (SEMS can be difficult. Classically, after recanalization of the bronchus, the stent is removed and replaced by a more adapted one. We report on two cases of proximal bronchial restenosis treated by insertion of an additional stent inside the lumen of the previously inserted stent using the stent-in-stent (SIS technique. The indications for the initial stent were malignancy in Patient 1 and posttransplant bronchial stenosis in Patient 2. Restenosis occurred at the proximal end of the stent within months in both cases. Stent removal and insertion of a new stent were considered, but this option was discarded because of an excessive risk of bronchial perforation and preference towards an alternative approach. In both cases, a second customized SEMS was placed using the SIS technique after ablation of the proximal end stenosis of the stent by argon plasma coagulation and/or dilation with a balloon. Recanalization of the bronchus was achieved in both cases without complications. The SIS technique is a valuable alternative to removal of SEMS in case of proximal bronchial restenosis.

  11. Clinical Application of Fully Covered Self-Expandable Metal Stents in the Treatment of Bronchial Fistula.

    Science.gov (United States)

    Cao, Ming; Zhu, Qiang; Wang, Wei; Zhang, Tian Xiao; Jiang, Min Zhong; Zang, Qi

    2016-09-01

    Background The study was designed to access the feasibility, safety, and efficacy of fully covered self-expandable metal stents in the treatment of bronchial fistula. Methods Clinical data of nine patients (seven males and two females) who were treated with placement of tracheobronchial or bronchial fully covered self-expandable metal stents from August 2005 to November 2011 were analyzed retrospectively. Among these patients, seven were diagnosed with bronchopleural fistula, one with tracheopleural fistula, and one with left main bronchoesophageal fistula. Eight had accompanying thoracic empyema. The fistula orifices ranged from 3.5 mm to 25 mm in diameter. All patients received topical anesthesia. L-shaped stents were placed in six patients and I-shaped stents in three under fluoroscopic guidance. After stent placement, patients with empyema were treated with pleural lavage. Results Stent placement in the tracheobronchial tree was successful in all patients, without procedure-related complications. The operating time was 5 to 16 minutes. A small amount of bubble overflowed from the intrathoracic drainage tube of only one patient. In the other patients, the bubble in the intrathoracic drainage tube disappeared immediately or angiography showed no overflow of contrast agent from the fistula orifice. The effective rate of fistula orifice closure after stent placement was 100%, with 88.9% rated as excellent. One patient coughed the stent out 5 days after placement and hence a new stent was placed. Among the patients with empyema, one died of septicemia arising from empyema on day 8 and another died of brain metastases of lung cancer 6 months after stent insertion with persistent empyema. In the other six patients, empyema resolved after 2 to 5 months (cure rate 75%). Seven patients were followed up for 3 to 36 months. During follow-up, one stent was removed 8 months after implantation due to difficult expectoration, without recurrent empyema. The remaining

  12. Magnetizable stent-grafts enable endothelial cell capture

    Energy Technology Data Exchange (ETDEWEB)

    Tefft, Brandon J. [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Uthamaraj, Susheil [Division of Engineering, Mayo Clinic, Rochester, MN (United States); Harburn, J. Jonathan [School of Medicine, Pharmacy and Health, Durham University, Stockton-on-Tees (United Kingdom); Hlinomaz, Ota [Department of Cardioangiology, St. Anne' s University Hospital, Brno (Czech Republic); Lerman, Amir [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Dragomir-Daescu, Dan [Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN (United States); Sandhu, Gurpreet S., E-mail: sandhu.gurpreet@mayo.edu [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States)

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance. - Highlights: • Magnetic stent-grafts were made from 2205 steel stents and polyurethane nanofibers. • Stent-grafts remained patent and formed a thin and uniform neointima when implanted. • Stent-grafts captured endothelial cells labeled with magnetic nanoparticles.

  13. Experimental study of different nickel-titanium memory tracheal stents in dogs

    International Nuclear Information System (INIS)

    Lang Xu; He Nengshu; Fan Hailun

    2009-01-01

    Objective: Since membrane -covered metal tracheal stent was applied successfully to treat the airway stenosis, it has been widely used and obtained satisfactory result during the past years. The purpose of our study was provide theoretical rational for treatment with membrane-covered tracheal stent by using animal experiment. Methods: The nickel- titanium memory stents of 22 mm in diameter and 6 cm in length were deployed in 18 dogs. The dogs were grouped into full- length membrane-covered group (n=6), partial-length membrane-covered group (membrane was covered for 4 cm in the medial part of the stent, n=6), and naked stent group (n=6). After the stent placement dysphagia or dysphonia was monitored daily. Twenty-four weeks later, the dogs were executed. Speiments were taken from the cephalic, medial, and caudal trachea under the stent. HE stain and proliferating cell nuclear antigen (PCNA) were evaluated. Results: After the stent placement, no dyspnea, dysphagia or dysphonia but cough was present in each dog. There was no significant difference in symptom between the three groups. Inflammation reaction, metaplasia from low columnar epithelium to spuamous epithelium, and mild granulation tissue hyperplasia in the underlying mucosa were present in each group. However, fibrosis and tracheal straitness were present only in the non-membrane-covered area, but not in the membrane-covered area. More PCNA expression was observed in the non-membrane -covered area than in the membrane-covered area. Conclusion: Both membrane-covered and non-membrane-covered stents can cause similar symptoms. However, the membrane -covered tracheal stent has good biological compatibility and would not induce tracheal straitness. The non-membrane -covered tracheal stent could induce a severe pathologic reaction and tracheal straitness. (authors)

  14. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young; Yuk, Soon Hong; Lee, Yong Seok

    2005-01-01

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models

  15. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yuk, Soon Hong [Hannam University, College of Engineering, Daejeon (Korea, Republic of); Lee, Yong Seok [Wonkwang University College of Medicine, Iksan (Korea, Republic of)

    2005-07-15

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models.

  16. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, F.A.B.; Spithoven, J.H.; Zeebregts, C.J.A.; Scharn, D.M.; Reijnen, M.M.

    2015-01-01

    PURPOSE: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. MATERIALS AND METHODS: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  17. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, Frederike A. B.; Spithoven, J. Hans; Zeebregts, Clark J.; Scharn, Dirk M.; Reijnen, Michel M. P. J.

    Purpose: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. Materials and Methods: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  18. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-07-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  19. Full covered self-expandable metal stents for the treatment of anastomotic leak using a silk thread.

    Science.gov (United States)

    Choi, Cheol Woong; Kang, Dae Hwan; Kim, Hyung Wook; Park, Su Bum; Kim, Su Jin; Hwang, Sun Hwi; Lee, Si Hak

    2017-07-01

    To evaluate the safety and effectiveness of fixation of the fully covered self-expandable metal stent (SEMS) placement using a silk thread for complete closure of an anastomotic leak. An anastomotic leak is a life-threatening complication after gastrectomy. Although the traditional treatment of choice was surgical re-intervention, an endoscopic SEMS can be used alternatively.During the study period, we retrospectively reviewed consecutive patients who received a modified covered SEMS capable of being fixed using a silk thread (Shim technique) due to an anastomotic leak after gastrectomy to prevent stent migration. Demographic data, stent placement and removal, clinical success, time to resolution, and complications were evaluated.A total of 7 patients underwent fully covered SEMS with a silk thread placement for an anastomotic leak after gastrectomy to treat gastric cancer. The patients' mean age was 71.3 ± 8.0 years. Man sex was predominant (85.7%). All patients' American Society of Anesthesiologists (ASA) scores were between I and III. Total gastrectomy was performed in 5 patients (71.4%) and proximal gastrectomy was performed in 2 patients (28.6%). The time between gastrectomy and stent insertion was 22.3 ± 11.1 days. The size of the leaks was 27.1 ± 11.1 mm. Technical success and complete leak closure were achieved in all patients. Stent migration was absent. All stents were removed between 4 and 6 weeks. Delayed esophageal stricture was found in 1 patient (14.2) and successfully resolved after endoscopic balloon dilation.For an anastomotic leak after gastrectomy, fully covered SEMS placement with a silk thread is an effective and safe treatment option without stent migration. The stent extraction time between 4 and 6 weeks was optimal without severe complications.

  20. [Clinical application of a fully covered self-expandable metallic stent in treatment of airway fistula].

    Science.gov (United States)

    Zhu, Qiang; Zang, Qi; Jiang, Zhong-min; Wang, Wei; Cao, Ming

    2013-06-01

    To assess the feasibility, safety and efficacy of the use of a fully covered self-expandable stent for the treatment of airway fistula. From August 2005 to November 2011, 9 patients underwent treatment by the introduction of a tracheo-bronchial or bronchial fully covered self-expandable metallic stent. There were 7 males and 2 females, aged from 28-65 years with a mean of 46 years. In this group, 7 cases were diagnosed as bronchopleural fistula, 1 case as tracheopleural fistula, 1 case as broncho-esophageal fistula, 8 cases with thoracic empyema. The fistula orifices were from 3.5-25.0 mm in diameter with a mean 8.4 mm. All patients received topical anesthesia, and L-shaped stent was placed in 6 patients and I-shaped stent in 3 patients under fluoroscopic guidance. After the stent placement, the patients with empyema were treated with continual irrigation of the empyema cavity. Stent placement in the tracheo-bronchial tree was technically successful in all patients, without procedure-related complications. The operating time was from 5-16 minutes, mean time (10 ± 4) minutes. Except for 1 patient, immediate closure of the airway fistula was achieved in the other patients after the procedure, as shown by the immediate cessation of bubbling in the chest drain system or the contrast examination. In this study, 1 patient coughed the inserted stent out due to irritable cough on the 5th day and had to receive repositioning of a new stent. Among the patients who were with empyema, 1 patient died of septicemia on the 8th day and 1 patient died of brain metastases from lung cancer 6 months after the stent insertion with empyema not cured, the other 6 patients' empyema healed from 2-5 months, mean time 3.7 months. Seven patients were followed from 3 to 36 months with a median of 13.5 months. During follow-up, 1 stent was removed from a patient 8 months after the stent implantation without empyema recurred. The remaining patient presented good tolerability to the existence of

  1. Clinical remission following endoscopic placement of retrievable, fully covered metal stents in patients with esophageal achalasia.

    Science.gov (United States)

    Zeng, Y; Dai, Y-M; Wan, X-J

    2014-01-01

    Metal stents may represent an alternative therapy in the treatment of achalasia. We therefore evaluated the effectiveness of retrievable, fully covered metal stents in patients with achalasia. Fifty-nine patients with achalasia were treated with retrievable, fully covered metal stents. Symptoms using a global symptom score (0-10), lower esophageal sphincter (LES) resting pressure, LES relaxation, and simultaneous contraction of the esophagus were analyzed before and 1 week and 1 month after intervention. Complications and treatment outcomes were followed up at 6, 12, 18, and 24 months postoperatively. Stent placement was successful, and clinical symptoms resolved (P treatment in patients with achalasia. © 2013 Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  2. Fully Covered Metallic Stents for the Treatment of Benign Airway Stenosis.

    Science.gov (United States)

    Dahlqvist, Caroline; Ocak, Sebahat; Gourdin, Maximilien; Dincq, Anne Sophie; Putz, Laurie; d'Odémont, Jean-Paul

    2016-01-01

    Introduction. We herein report our experience with new fully covered self-expanding metallic stents in the setting of inoperable recurrent benign tracheobronchial stenosis. Methods. Between May 2010 and July 2014, 21 Micro-Tech® FC-SEMS (Nanjing Co., Republic of Korea) were placed in our hospital in 16 patients for inoperable, recurrent (after dilatation), and symptomatic benign airway stenosis. Their medical files were retrospectively reviewed in December 2014, with focus on stent's tolerance and durability data. Results. Twenty-one stents were inserted: 13 for posttransplant left main bronchus anastomotic stricture, seven for postintubation tracheal stenosis, and one for postlobectomy anastomotic stricture. Positioning was easy for all of them. Stents were in place for a mean duration of 282 days. The most common complications were granulation tissue development (35%), migration (30%), and sputum retention (15%). Fifty-five % of the stents (11/20) had to be removed because of various complications, without difficulty for all of them. None of the patients had life-threatening complications. Conclusion. Micro-Tech FC-SEMS were easy to position and to remove. While the rate of complications requiring stent removal was significant, no life-threatening complication occurred. Further studies are needed to better define their efficacy and safety in the treatment of benign airway disease.

  3. Covered Metallic Stents With an Anti-Migration Design vs. Uncovered Stents for the Palliation of Malignant Gastric Outlet Obstruction: A Multicenter, Randomized Trial

    Science.gov (United States)

    Lee, Hyuk; Min, Byung-Hoon; Lee, Jeong Hoon; Shin, Cheol Min; Kim, Younjoo; Chung, Hyunsoo; Lee, Sang Hyub

    2015-01-01

    OBJECTIVES: Previous studies reported comparable stent patency between covered self-expandable metallic stents (SEMS) and uncovered SEMS (UCS) for palliation of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the efficacy and safety of the newly developed WAVE-covered SEMS (WCS), which has an anti-migration design, compared with UCS in gastric cancer patients with symptomatic GOO. METHODS: A total of 102 inoperable gastric cancer patients with symptomatic GOO were prospectively enrolled from five referral centers and randomized to undergo UCS or WCS placement. Stent patency and recurrence of obstructive symptoms were assessed at 8 weeks and 16 weeks after stent placement. RESULTS: At the 8-week follow-up, both stent patency rates (72.5% vs. 62.7%) and re-intervention rates (19.6% vs. 19.6%) were comparable between the WCS and the UCS groups. Both stent stenosis (2.4% vs. 8.1%) and migration rates (9.5% vs. 5.4%) were comparable between WCS and UCS groups. At the 16-week follow-up, however, the WCS group had a significantly higher stent patency rate than the UCS group (68.6% vs. 41.2%). Re-intervention rates in the WCS and UCS groups were 23.5% and 39.2%, respectively. Compared with the UCS group, the WCS group had a significantly lower stent restenosis rate (7.1% vs. 37.8%) and a comparable migration rate (9.5% vs. 5.4%). Overall stent patency was significantly longer in the WCS group than in the UCS group. No stent-associated significant adverse events occurred in either the WCS or UCS groups. In the multivariate analysis, WCS placement and chemotherapy were identified as independent predictors of 16-week stent patency. CONCLUSIONS: WCS group showed comparable migration rate and significantly more durable long-term stent patency compared with UCS group for the palliation of GOO in patients with inoperable gastric cancer. PMID:26372507

  4. Efficacy and safety of a new fully covered self-expandable non-foreshortening metal esophageal stent.

    Science.gov (United States)

    Dua, Kulwinder S; Latif, Sahibzada U; Yang, Juliana F; Fang, Tom C; Khan, Abdul; Oh, Young

    2014-10-01

    Fully covered esophageal self-expandable metal stents (SEMSs) are potentially removable but can be associated with high migration rates. For precise positioning, non-foreshortening SEMSs are preferred. Recently, a new fully covered non-foreshortening SEMS with anti-migration features was introduced. To evaluate the efficacy and safety of this new esophageal SEMS. Retrospective study. Single, tertiary-care center. Consecutive patients with malignant and benign strictures with dysphagia grade of ≥3 and patients with fistulas/leaks were studied. Stent placement and removal. Technical success in stent deployment/removal, efficacy in relieving dysphagia and sealing fistulas/leaks, and adverse events. Forty-three stents were placed in 35 patients (mean [± standard deviation] age 65 ± 11 years; 31 male), 24 for malignant and 11 for benign (5 strictures, 6 leaks) indications. Technical success in precise SEMS placement was 100%. The after-stent dysphagia grade improved significantly (at 1 week: 1.5 ± 0.7; at 4 weeks: 1.2 ± 0.4; baseline: 3.8 ± 0.4; P stents were removed for clinical indications, with technical success of 100%. All leaks sealed after SEMS placement and did not recur after stent removal. All benign strictures recurred after stent removal. Adverse events included migration (14%), chest pain (11%), and dysphagia from tissue hyperplasia (6%). There was no stent-related mortality. Nonrandomized, single-center study. The new esophageal SEMS was effective in relieving malignant dysphagia, allowed for precise placement, and was easily removable. It was effective in treating benign esophageal fistulas and leaks. Stent-related adverse events were acceptable. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  5. Covered Balloon-Expanding Stents in Airway Stenosis.

    Science.gov (United States)

    Majid, Adnan; Kheir, Fayez; Chung, Jey; Alape, Daniel; Husta, Bryan; Oh, Scott; Folch, Erik

    2017-04-01

    The balloon-expanding stents are widely available but rarely described for use within the tracheobronchial tree. This report describes our experience with these stents in airway stenosis particularly as a lobar salvage therapy. This was a retrospective review of all records in which the balloon-expanding stents were used at a tertiary medical center. Ages, sex, location of stenosis, etiology of stenosis, stent size, duration of stent placement and associated interventions for airway stenosis were recorded. Patient's self-reported respiratory symptoms, dyspnea scale, and radiographic imaging at baseline and after stent placement were also reported. Twenty-one Atrium iCAST stents were inserted in 18 patients with malignant and benign airway disease. The median age was 69.5 years (interquartile range, 53.5 to 74). Most stents (n=20, 95%) were deployed in the lobar airways. There was a significant improvement in the modified Medical Research Council dyspnea scale from median of 3 to 2 (Pstent placement was achieved in 15 patients (83%). No deaths were related to airway stenting complications. Adverse events related to stents included migration (n=2, 9.5%), granulation tissue formation (n=2, 9.5%) and mucus plugging (n=1, 4.8%). Lobar stenting with balloon-expanding metallic stents appears feasible, safe and improves symptoms as well as radiographic atelectasis in patients with lobar airway stenosis in this small case series. Larger studies are needed to confirm this observation and to address long-term safety.

  6. Mechanisms of biliary stent clogging: confocal laser scanning and scanning electron microscopy.

    Science.gov (United States)

    van Berkel, A M; van Marle, J; Groen, A K; Bruno, M J

    2005-08-01

    Endoscopic insertion of plastic biliary endoprostheses is a well-established treatment for obstructive jaundice. The major limitation of this technique is late stent occlusion. In order to compare events involved in biliary stent clogging and identify the distribution of bacteria in unblocked stents, confocal laser scanning (CLS) and scanning electron microscopy (SEM) were carried out on two different stent materials - polyethylene (PE) and hydrophilic polymer-coated polyurethane (HCPC). Ten consecutive patients with postoperative benign biliary strictures were included in the study. Two 10-Fr stents 9 cm in length, one made of PE and the other of HCPC, were inserted. The stents were electively exchanged after 3 months and examined using CLS and SEM. No differences were seen between the two types of stent. The inner stent surface was covered with a uniform amorphous layer. On top of this layer, a biofilm of living and dead bacteria was found, which in most cases was unstructured. The lumen was filled with free-floating colonies of bacteria and crystals, surrounded by mobile laminar structures of mucus. An open network of large dietary fibers was seen in all of the stents. The same clogging events occurred in both PE and HCPC stents. The most remarkable observation was the identification of networks of large dietary fibers, resulting from duodenal reflux, acting as a filter. The build-up of this intraluminal framework of dietary fibers appears to be a major factor contributing to the multifactorial process of stent clogging.

  7. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  8. Malignant Hilar Biliary Obstruction: Treatment by Means of Placement of a Newly Designed Y-Shaped Branched Covered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Jong Hyouk, E-mail: xell1015@naver.com; Jung, Gyoo-Sik, E-mail: gsjung@medimail.co.kr; Park, Jung Gu [Kosin University College of Medicine, Departments of Diagnostic Radiology (Korea, Republic of); Kang, Byung Chul [Ewha Womans University College of Medicine, Departments of Radiology, Mokdong Hospital (Korea, Republic of); Shin, Dong-Hoon [Kosin University College of Medicine, Departments of General Surgery (Korea, Republic of); Yun, Byung Chul; Lee, Sang Uk [Kosin University College of Medicine, Departments of Internal Medicine (Korea, Republic of)

    2016-04-15

    PurposeTo evaluate the technical feasibility and clinical efficacy of placement of a newly designed Y-shaped branched covered stent for palliative treatment of malignant hilar biliary obstruction.MethodsFrom June 2011 to September 2014, 34 consecutive patients with malignant hilar biliary obstruction underwent percutaneous placement of a Y-shaped branched covered stent for palliative treatment. Technical and clinical success, complications, cumulative patient survival, and stent patency were evaluated.ResultsStent placement was technically successful in all patients. All patients showed adequate biliary drainage on the follow-up cholangiogram. Mean serum bilirubin level (10.9 mg/dl) decreased significantly 1 week (5.7 mg/dl) and 1 month (2.6 mg/dl) after stent placement (p < 0.01). Complications associated with the procedure included hemobilia (n = 3) and biloma (n = 1). During the mean follow-up period of 225 (range 12–820) days, nine patients (26.5 %) developed stent occlusion caused by tumor overgrowth (n = 8) and sludge (n = 1). Two of them underwent coaxial placement of a second stent with good results. The median survival time was 281 days and median primary stent patency was 337 days. There were no significant differences in the patient survival and stent patency rates in relation to age, sex, or Bismuth type.ConclusionPercutaneous placement of the Y-shaped branched covered stent seems to be technically feasible and clinically effective for palliative treatment of malignant hilar biliary obstruction.

  9. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Pausawasadi, Nonthalee [Department of Medicine, Siriraj Hospital, Mahidol University, Bangkok (Thailand); Soontornmanokul, Tanassanee; Rerknimitr, Rungsun [Department of Medicine, Chulalongkorn University, Bangkok (Thailand)

    2012-02-15

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  10. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    International Nuclear Information System (INIS)

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee; Rerknimitr, Rungsun

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  11. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Science.gov (United States)

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks. PMID:22563290

  12. Clinical feasibility of a new through-the-scope fully covered esophageal self-expandable metallic stent: an in vivo animal study.

    Science.gov (United States)

    Cheon, Young Koog; Lee, Tae Yoon; Sung, In Kyung; Shim, Chan Sup

    2014-01-01

    Most delivery devices used for esophageal stents for obstructing esophageal cancer have a diameter of 5-8 mm, a size that is too large to pass through the endoscopic working channel. The conventional esophageal stent requires multiple endoscopic procedures for implantation. The purpose of the present study was to evaluate the clinical feasibility of a newly developed fully covered, self-expanding, through-the-scope (TTS) esophageal stent in a porcine model. Eight mini pigs were used. Each animal underwent placement of a fully covered TTS stent (Hanarostent® Esophagus TTS) and the upper part of the stent was fixed by suturing with nylon. Fluoroscopy was carried out every week to assess migration of the stent. Follow-up endoscopy was done every month for 3 months to evaluate the status of the membrane, stent mesh, grade of tissue hyperplasia, and mucosal changes at both ends of the stent. All stents were successfully and easily deployed, and were placed without any distortion in the stent or without rupture of the membrane. In two cases, stent migration was observed after 8 weeks. No case of membrane disruption, stent mesh disruption or tissue hyperplasia at either end of the stent was found at the completion of the study. Our findings indicate that the new fully covered self-expanding TTS esophageal stent is easy and simple to implant, and no significant distortion of mesh or disruption of membrane was observed. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  13. Fully Covered Metallic Stents for the Treatment of Benign Airway Stenosis

    Directory of Open Access Journals (Sweden)

    Caroline Dahlqvist

    2016-01-01

    Full Text Available Introduction. We herein report our experience with new fully covered self-expanding metallic stents in the setting of inoperable recurrent benign tracheobronchial stenosis. Methods. Between May 2010 and July 2014, 21 Micro-Tech® FC-SEMS (Nanjing Co., Republic of Korea were placed in our hospital in 16 patients for inoperable, recurrent (after dilatation, and symptomatic benign airway stenosis. Their medical files were retrospectively reviewed in December 2014, with focus on stent’s tolerance and durability data. Results. Twenty-one stents were inserted: 13 for posttransplant left main bronchus anastomotic stricture, seven for postintubation tracheal stenosis, and one for postlobectomy anastomotic stricture. Positioning was easy for all of them. Stents were in place for a mean duration of 282 days. The most common complications were granulation tissue development (35%, migration (30%, and sputum retention (15%. Fifty-five % of the stents (11/20 had to be removed because of various complications, without difficulty for all of them. None of the patients had life-threatening complications. Conclusion. Micro-Tech FC-SEMS were easy to position and to remove. While the rate of complications requiring stent removal was significant, no life-threatening complication occurred. Further studies are needed to better define their efficacy and safety in the treatment of benign airway disease.

  14. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    International Nuclear Information System (INIS)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho; Ko, Ji Ho; Jeong, Kyung Soon

    2007-01-01

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

  15. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of University, Masan (Korea, Republic of); Jeong, Kyung Soon [University of Ulsan Colleg of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-09-15

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer.

  16. How to design the optimal self-expandable oesophageal metallic stents: 22 years of experience in 645 patients with malignant strictures.

    Science.gov (United States)

    Na, Han Kyu; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Kang, Min Kyoung; Lee, Jongjin; Oh, Se Jin

    2013-03-01

    To evaluate the clinical efficacy and safety of self-expandable metallic stent (SEMS) placement for malignant oesophageal strictures and their relationship with stent designs. Seven generations of SEMS were used to treat 645 consecutive patients with oesophageal strictures. Logistic regression models were constructed to identify predictive factors associated with complications. Stent placement was technically successful in 641 of 645 patients (99.4%). The clinical success rate was 95.5%. There were 260 (40.3%) complications after stent placement. Due to complications, 68 stents were removed; 66 of 68 stents (97.1%) were removed successfully. Stainless steel (SS) stents (odds ratio [OR] 4.18; 95% confidence interval [CI] 2.10, 8.32) and radiation therapy (RT) before stent placement (OR 4.23; CI 2.02, 8.83) were significantly associated with severe pain. Flared ends (OR 9.63; CI 3.38, 27.43), stricture length stent diameter stent migration. Polyurethane membranes were associated with more frequent tumour ingrowth than polytetrafluoroethylene (PTFE) membranes (P = 0.002). Despite the relatively high complication rate, retrievable self-expandable PTFE-covered nitinol stents equipped with a head and a tail appeared to be an effective treatment for malignant oesophageal strictures.

  17. Radioactive metallic stent for the treatment of esophageal cancer in animal model and clinical trial

    Energy Technology Data Exchange (ETDEWEB)

    Park, K. B. [Korea Atomic Energy Research Institute, Taejeon (Korea); Lee, J. D. [Yonsei Univ., Seoul (Korea)

    2000-03-01

    The purpose of this study is to evaluate tissue response of self-expandable metallic stent covered Ho-166 in normal canine esophagus. Ho-166 was incorporated within polyurethan and covered over the outer surface of self-expandable metallic stents(diameter ; 18mm, length ; 40mm). Metallic stents with radioactivity of 4.0-7.8mCi (Group A), 1.0-1.8mCi (Group B) and 0.5-0.7mCi (Group C) were placed in normal mid-esophagus in twelve dogs (Group A), five (Group B) and another five dogs (Group C) respectively. Estimated radiation dose was 200-392Gy in Group A, 50-90Gy in Group B, and 25-35 Gy in Group C. The dogs were sacrified at two or three months later. In group A, mid-esophagus stricture, mucosal ulceration were found. Sereve fibrosis and degeneration of muscular propria, outer one half were found in three and complete fibrosis of esophageal wall in seven and fibrosis of esophageal wall and periesophageal soft tissue in two. In group B, glandular atrophy and submucosal fibrosis were found but muscular layer was intact. In group C, no histological change was demonstrated in three but submucosal inflammation and glandular atrophy with intact mucosa in two. Self-expandable metallic stent covered with Ho-166 may be used safely in esophagus without complication. 21 refs., 17 figs., 2 tabs. (Author)

  18. Treatment of traumatic internal carotid artery pseudoaneurysms with willis covered stents: a midterm follow-up result

    International Nuclear Information System (INIS)

    Wang Wu; Li Minghua; Li Yongdong; Gu Binxian; Fang Chun; Tan Huaqiao; Wang Ju; Zhang Peilei

    2010-01-01

    Objective: To evaluate the efficacy and mid-term follow-up results of endovascular treatment with Willis covered stent for traumatic pseudoaneurysms located in the internal carotid artery (ICA). Methods: ICA angiography was performed in 38 patients with traumatic brain and neck injury. Of the 38 patients, 13 delayed traumatic pseudoaneurysms were found. All the pseudoaneurysms were treated with Willis covered stents. Follow-up angiography was performed at 1, 3, 6 and 12 months after the procedure, and the results were categorized as complete or incomplete occlusion. Clinical manifestations were graded as full recovery, improvement, unchanged and aggravation. Results: Willis covered stent placement was technically successful in all traumatic pseudoaneurysms. No procedure-related complications occurred. The initial angiographic results showed a complete occlusion in 9 patients, and an incomplete occlusion in 4. The angiographic follow-up within 3-12 months exhibited a complete occlusion in 12 patients and the parent arteries remained patency in all patients. The clinical follow-up observation demonstrated that full recovery was obtained in 11 patients, clinical improvement in one, and unchanged condition in one. No morbidity or mortality occurred. Conclusion: Willis covered stent implantation is a feasible and practical treatment for traumatic pseudoaneurysms located in the ICA. This technique can well preserve the parent artery with excellent therapeutic results. (authors)

  19. Customized Hinged Covered Metallic Stents for the Treatment of Benign Main Bronchial Stenosis.

    Science.gov (United States)

    Han, Xinwei; Al-Tariq, Quazi; Zhao, Yanle; Li, Lei; Cheng, Zhe; Wang, Huaqi; Liu, Chao; Jiao, Dechao; Wu, Gang

    2017-08-01

    To address the limitations of silicone stents, we designed a hinged self-expandable covered metallic stent. The aim of this study was to evaluate the safety and efficacy of the customized stents in clinical applications. This was a retrospective analysis. Under conscious sedation and local anesthesia, the stents were implanted or removed by interventional radiologists, with fluoroscopic guidance. Of 24 patients with benign main bronchial stenosis, stents were successfully placed in 21 (87.5%). The low-pressure balloon before dilation failed in 1 case (4.17%) of left main bronchial cicatricial stenosis. In 2 other cases (8.33%), stent placement was abandoned. Stents were successfully removed between 29 and 103 days after the procedure. After stent removal, the follow-up lasted for at least 12 months. Restenosis occurred only in 1 case (4.55%) owing to bronchial collapse 3 days after stent removal. Dyspnea occurred in another case (4.55%) at 2 months after retrieval; recurrence was confirmed using bronchoscopy, leading to a left pneumonectomy. The described procedure is safe and easy to be performed and avoids the use of intubation, bronchoscopy, and general anesthesia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Temporary placement of covered retrievable expandable nitinol stents with barbs in high-risk surgical patients with benign prostatic hyperplasia: work in progress.

    Science.gov (United States)

    Kim, Choung-Soo; Song, Ho-Young; Jeong, In Gab; Yeo, Hyun Jin; Kim, Eun-Young; Park, Jung-Hoon; Yoon, Chang Jin; Paick, Sung Hyun; Park, Sang Woo; Bae, Jae-Ik; Won, Je Hwan

    2011-10-01

    To report the use of a newly constructed, covered, retrievable, expandable nitinol stent with barbs to overcome the problem of stent migration associated with conventional covered prostatic expandable stents and to evaluate prospectively the technical feasibility and clinical effectiveness of the stents in patients with benign prostatic hyperplasia (BPH). A covered retrievable expandable nitinol stent with four barbs was placed with use of an 18-F stent delivery system in seven consecutive patients with symptomatic BPH who had high operative risks. Age range of patients was 62-83 years (mean 74 years). In cases in which the stent migrated, it was replaced with a stent with eight barbs. The stents were routinely removed 4 months after placement using a 21-F stent removal set. Stent placement was technically successful and well tolerated in six of the seven patients. The remaining patient needed a second stent placement after removal of the first stent. The stent with four barbs migrated into the urinary bladder in four patients (57%); three of these patients received a second stent with eight barbs with good results, and the fourth patient did not need further treatment because his symptoms improved. Routine removal of the stent 4 months after placement was performed in three of the seven patients with good results. Retrievable stents with eight barbs seem to overcome the problem of stent migration associated with conventional prostatic expandable stents. Preliminary results suggest that stents with barbs are both feasible and effective in patients with BPH. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  1. Late Migration of Two Covered Biliary Stents Through a Spontaneous Bilioenteric Fistula in a Patient with Malignant Biliary Obstruction

    International Nuclear Information System (INIS)

    Krokidis, Miltiadis E.; Hatzidakis, Adam A.; Manousaki, Eirini G.; Gourtsoyiannis, Nicholas C.

    2008-01-01

    We report a case of simultaneous late migration of two ePTFE-FEP covered biliary endoprostheses (Viabil, W.L. Gore, Flagstaff, AZ, USA) that were percutaneously implanted for the treatment of malignant obstructive jaundice. The first Viabil covered stent was placed successfully without any evidence of dislocation or other complication during follow-up. Occlusion of the stent occurred 4 months later and was treated with the placement of a second stent of the same type. Thirteen months later the patient became symptomatic. Percutaneous transhepatic cholangiography (PTC) revealed the presence of a choledocho-duodenal fistula and the disappearance of the two endoprostheses previously implanted. A third metallic stent was then percutaneously positioned through the bilioenteric fistula. The computed tomography scan that followed for the detection of the metallic bodies did not reveal the dislocated metallic stents. Stent migration is a well-known complication of uncovered metallic stents, though Viabil stent migration is assumed to be most unlikely to happen due to the stent's anchoring barbs. Furthermore, the stent had already been tightly fixed by tumor over- and ingrowth, as recognized in previous imaging. This is a very unusual case, describing the disappearance of two metallic foreign bodies encapsulated by tumor

  2. Randomized multicenter study of multiple plastic stents vs. covered self-expandable metallic stent in the treatment of biliary stricture in chronic pancreatitis.

    Science.gov (United States)

    Haapamäki, Carola; Kylänpää, Leena; Udd, Marianne; Lindström, Outi; Grönroos, Juha; Saarela, Arto; Mustonen, Harri; Halttunen, Jorma

    2015-07-01

    The use of covered self-expandable metallic stents (cSEMS) in benign biliary indications is evolving. The aim of the study was to assess the safety and feasibility of cSEMS compared with multiple plastic stents in the treatment of benign biliary stricture (BBS) caused by chronic pancreatitis. This was a prospective, multicenter, randomized study of 60 patients with BBS caused by chronic pancreatitis. All patients received an initial plastic stent before randomization. At randomization, the stent was replaced either with a single cSEMS or three plastic stents. After 3 months, the position of the cSEMS was checked or another three plastic stents were added. At 6 months after randomization, all stents were removed. Clinical follow-up including abdominal ultrasound and laboratory tests were performed at 6 months and 2 years after stent removal. Two patients dropped out of the cSEMS group before stent removal. In April 2014, the median follow-up was 40 months (range 1 - 66 months). The 2-year, stricture-free success rate was 90 % (95 % confidence interval [CI] 72 % - 97 %) in the plastic stent group and 92 % (95 %CI 70 % - 98 %) in the cSEMS group (P = 0.405). There was one late recurrence in the plastic stent group 50 months after stent removal. Stent migration occurred three times (10 %) in the plastic stent group and twice in the cSEMS group (7 %; P = 1.000). A 6-month treatment with either six 10-Fr plastic stents or with one 10-mm cSEMS produced good long-term relief of biliary stricture caused by chronic pancreatitis.Study registered at ClinicalTrials.gov (NCT01085747). © Georg Thieme Verlag KG Stuttgart · New York.

  3. Fully covered self-expanding metal stents are effective for benign esophagogastric disruptions and strictures.

    Science.gov (United States)

    Wilson, Jennifer L; Louie, Brian E; Farivar, Alexander S; Vallières, Eric; Aye, Ralph W

    2013-12-01

    Self-expanding fully covered metal stents (CSs) are ideal for use in benign esophagogastric disease. We reviewed our experience with CS to evaluate outcomes, to determine a role for CS in a standard treatment for benign esophageal conditions, and to compare our results with recently published studies. We performed a retrospective chart review from 2005 to 2012. A total of 57 CSs were placed in 44 patients. Indications were stricture (11 patients), anastomotic leak (20), perforation (7), and tracheoesophageal fistulae (6). For GI tract disruptions, open repair or diversion was avoided in 31/33 patients (93.9 %) but required an associated drainage procedure in 22/33 (67 %) patients. Resolution does not depend on achieving radiological control with 6/26 (23 %) having evidence of a persistent leak. Benign strictures were dilated at a mean of 3.7 times prior to stenting. Adjunctive intra-mucosal steroid injections were used in 8/11 patients. Stents were removed at a mean of 33 days. At a mean of 283 days of follow-up, 6/11 (54.5 %) had symptom resolution. The most common complication was stent migration occurring in 17.5 % of patients overall. Covered stents are an effective adjunct in the management of benign upper gastrointestinal tract fistulae, leaks, perforations and benign strictures.

  4. Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial

    Energy Technology Data Exchange (ETDEWEB)

    Lammer, Johannes, E-mail: jlammer@gmx.at, E-mail: johannes.lammer@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); Zeller, Thomas, E-mail: thomas.zeller@universitaets-herzzentrum.de [Universitaets-Herzzentrum Freiburg-Bad Krozingen, Department of Angiology (Germany); Hausegger, Klaus A., E-mail: klaus.hausegger@lkh-klu.at [Klinikum Klagenfurt, The Department of Diagnostic and Interventional Radiology (Austria); Schaefer, Philipp J., E-mail: jp.schaefer@rad.uni-kiel.de [University Clinics Schleswig-Holstein, The Department of Radiology (Germany); Gschwendtner, Manfred, E-mail: manfred.gschwendtner@elisabethinen.or.at [Elisabethinen Hospital, The Department of Diagnostic and Interventional Radiology (Austria); Mueller-Huelsbeck, Stefan, E-mail: muehue@diako.de [Diakonissen Hospital, The Department of Diagnostic and Interventional Radiology (Germany); Rand, Thomas, E-mail: thomas.rand@wienkav.at [Hietzing Hospital, The Department of Radiology (Austria); Funovics, Martin, E-mail: martin.funovics@meduniwien.ac.at; Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); Rastan, Aljoscha, E-mail: aljoscha.rastan@universitaets-herzzentrum.de [Universitaets-Herzzentrum Freiburg-Bad Krozingen, Department of Angiology (Germany); Gschwandtner, Michael, E-mail: michael.gschwandtner@meduniwien.ac.at [Medical University Vienna, The Department of Angiology (Austria); Puchner, Stefan, E-mail: stefan.puchner@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); and others

    2015-02-15

    PurposeThe hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only.MethodsA prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN{sup ®} Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN{sup ®} versus 17.3 ± 6.6 cm in the BMS group.ResultsThe 24-month primary patency rates in the VIABAHN{sup ®} and BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN{sup ®} versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN{sup ®} versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN{sup ®} versus the BMS group, respectively.ConclusionAt 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244)

  5. Bending behaviors of fully covered biodegradable polydioxanone biliary stent for human body by finite element method.

    Science.gov (United States)

    Liu, Yanhui; Zhu, Guoqing; Yang, Huazhe; Wang, Conger; Zhang, Peihua; Han, Guangting

    2018-01-01

    This paper presents a study of the bending flexibility of fully covered biodegradable polydioxanone biliary stents (FCBPBs) developed for human body. To investigate the relationship between the bending load and structure parameter (monofilament diameter and braid-pin number), biodegradable polydioxanone biliary stents derived from braiding method were covered with membrane prepared via electrospinning method, and nine FCBPBSs were then obtained for bending test to evaluate the bending flexibility. In addition, by the finite element method, nine numerical models based on actual biliary stent were established and the bending load was calculated through the finite element method. Results demonstrate that the simulation and experimental results are in good agreement with each other, indicating that the simulation results can be provided a useful reference to the investigation of biliary stents. Furthermore, the stress distribution on FCBPBSs was studied, and the plastic dissipation analysis and plastic strain of FCBPBSs were obtained via the bending simulation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Endoscopic stenting as bridge-to-surgery (BTS) in left-sided obstructing colorectal cancer: Experience with conformable stents.

    Science.gov (United States)

    Parodi, Andrea; De Ceglie, Antonella; De Luca, Luca; Conigliaro, Rita; Naspetti, Riccardo; Arpe, Paola; Coccia, Gianni; Conio, Massimo

    2016-11-01

    Compared to emergency surgery, self-expandable metallic stents are effective and safe when used as bridge-to-surgery (BTS) in operable patients with acute colorectal cancer obstruction. In this study, we report data on the new conformable colonic stents. To evaluate clinical effectiveness of conformable stents as BTS in patients with acute colorectal cancer obstruction. This was a retrospective study. The study was conducted at six Italian Endoscopic Units. Data about patients with acute malignant colorectal obstruction were collected between 2007 and 2012. All patients were treated with conformable stents as BTS. Technical success, clinical success, rate of primary anastomosis and colostomy, early and late complications were evaluated. Data about 88 patients (62 males) were reviewed in this study. Conformable SEMS were correctly deployed in 86 out of 88 patients, with resolution of obstruction in all treated patients. Tumor resection with primary anastomosis was possible in all patients. A temporary colostomy was performed in 40. Early complications did not occur. Late complications occurred in 11 patients. Stent migration was significantly higher in patients treated with partially-covered stents compared to the uncovered group (35% vs. 0%, P<0.001). Endoscopical re-intervention was required in 12% of patients. One patient with rectal cancer had an anastomotic dehiscence after surgery and he was successfully treated with endoscopic clipping. One year after surgery, all patients were alive and local recurrence have not been documented. This was a retrospective and uncontrolled study. Preliminary data from this large case series are encouraging, with a high rate of technical and clinical success and low rate of clinically relevant complications. Partially-covered SEMS should be avoided in order to reduce the risk of endoscopic re-intervention. Copyright © 2016. Published by Elsevier Masson SAS.

  7. Self-expandable metalic endotracheal stent

    International Nuclear Information System (INIS)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author)

  8. Self-expandable metalic endotracheal stent

    Energy Technology Data Exchange (ETDEWEB)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author).

  9. Endoscopic Removal of an Esophageal Stent After Diffuse Hyperplastic Tissue Ingrowth

    Directory of Open Access Journals (Sweden)

    Ivo Boškoski

    2014-01-01

    Full Text Available Endoscopic placement of esophageal Self-Expandable Metal Stents (SEMS is a therapeutic option for post-surgical esophageal leaks. Partially covered SEMS are mainly designed for malignant esophageal strictures, but are used off-label to close post-surgical leaks due to their lower migration rate than fully covered SEMS, and better adherence to the esophageal wall. Partially covered esophageal SEMS can achieve post-surgical fistula healing, but their removal is difficult due to tissue ingrowth through the uncovered part. A challenging case of a difficult removal of a partially covered esophageal SEMS (remove the indefinite article is (below presented.

  10. Endoscopic stent suture fixation for prevention of esophageal stent migration during prolonged dilatation for achalasia treatment.

    Science.gov (United States)

    Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F

    2017-04-01

    The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Covered stent to exclude intravascular thrombus.

    Science.gov (United States)

    Liistro, Francesco; Stankovic, Goran; Di Mario, Carlo; Montorfano, Matteo; Briguori, Carlo; Colombo, Antonio

    2002-04-01

    To describe the utility of stent-graft implantation to avoid distal embolization from a large thrombus-containing lesion. A 67-year-old man was evaluated for recent onset of disabling left leg claudication. Angiography disclosed a mobile lobular mass occluding the left common iliac artery; irregular staining suggested an atherothrombotic lesion. Through a percutaneous ipsilateral access and an 8-F sheath, a balloon-expandable Jostent peripheral stent-graft was positioned with the distal edge immediately proximal to the internal iliac artery ostium. A prominent "waist" at the center of the balloon confirmed entrapment of the thrombotic mass. Completion angiography showed an optimal result with no residual stenosis or evidence of distal embolization. At 6-month follow-up, the patient was asymptomatic with angiographically documented luminal patency and no evidence of in-stent stenosis. Stent-graft implantation appears a viable treatment alternative for thrombus-containing lesions, particularly when the thrombotic material is localized or is in a large vessel.

  12. Pilot study of a novel, large-bore, fully covered self-expandable metallic stent for unresectable distal biliary malignancies.

    Science.gov (United States)

    Mukai, Tsuyoshi; Yasuda, Ichiro; Isayama, Hiroyuki; Iwashita, Takuji; Itoi, Takao; Kawakami, Hiroshi; Kogure, Hirofumi; Nakai, Yousuke

    2016-09-01

    In patients with unresectable malignant distal biliary obstruction, covered self-expandable metallic stents (CSEMS) may remain patent longer than uncovered self-expandable metallic stents as a result of tumor ingrowth prevention. One main cause of recurrent biliary obstruction (RBO) in CSEMS is sludge formation, which can be prevented using a large-bore stent. Therefore, we developed a novel, 12-mm diameter fully covered SEMS (FCSEMS) and investigated its clinical safety, efficacy, and rate of adverse events. This prospective, multicenter pilot study, which ran between June 2011 and November 2012, included 38 consecutive patients with unresectable malignant distal biliary obstruction. All patients underwent endoscopic insertion of our novel stent. Primary endpoint was non-RBO rate 6 months after placement. Technical and functional success rates of the procedures were 100%. Six-month non-RBO rate was 50%, and median time to RBO was 184 days. Median survival time was 241 days. Twelve patients died within 6 months after stent placement without RBO. RBO was observed in 10 patients (26%), with seven experiencing stent occlusion and three experiencing stent migration. Adverse events other than RBO (at Stent removal for reintervention was successfully completed in eight patients. Our novel FCSEMS may be safe and effective for managing malignant distal obstruction with an acceptable incidence of adverse events. © 2016 Japan Gastroenterological Endoscopy Society.

  13. Combined-stent covered technique and single covered stent technique for transjugular intrahepatic porto-systemic shunt: a prospective randomized controlled study

    International Nuclear Information System (INIS)

    Wang Changming; Li Xuan; Fu Jun; Lu Xianjun; Luan Jingyuan; Li Tianrun; Zhao Jun; Dong Guoxiang

    2014-01-01

    Objective: To compare the technique of combined stents with that of single stent-graft for the construction of transjugular intrahepatic porto-systemic shunt (TIPS) and to discuss their clinical outcomes. Methods: During the period from April 2011 to Dec. 2012, a total of 30 patients with upper gastrointestinal bleeding due to portal hypertension were admitted to the hospital. TIPS procedure was carried out in all the 30 patients. The patients were randomly allocated into either combined-stent group (n=17) or stent-graft group (control group, n=13) on the basis of a computer-generated randomization sequence. The PSC quality control, the patency rate of portal vein branches and the shunts, the incidence of encephalopathy and the survival rate of the two groups were documented and analyzed. Results: Technical success rate was 100%. After the treatment, in both groups the PSG became significantly lower than the PSG determined before the treatment (P<0.000). According to quality control chart, the of combined stents was superior to stent-graft technique in effectively controlling PSG. Five days after TIPS, the ammonia level in the combined- stent group was significantly decreased (P=0.029), while in the control group the ammonia level showed no significant changes (P=0.065). One patient died shortly after TIPS. The median follow- up time was 181 days. During the follow-up period death occurred in 3 cases in each group. The difference in the survival rate between the two groups was no significant (P=0.906). Of the three patients who developed encephalopathy, two were in the combined-stent group and one was in the control group. After medication the symptoms of encephalopathy were relieved. The patency rate of the shunts was 100% and the re-bleeding rate was 0% for both groups. The patency rate of portal vein branches was significantly higher in the combined-stent group than that in the control group (P=0.039). Conclusion: For the construction of TIPS, the technique of

  14. Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward; Patel, Rahul S.; Scott Nowakowski, F.; Lookstein, Robert A.; Fischman, Aaron M. [Icahn School of Medicine at Mount Sinai, Interventional Radiology Section, Department of Radiology (United States)

    2016-06-15

    PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloon retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.

  15. In Vivo Study of Polyurethane-Coated Gianturco-Rosch Biliary Z-Stents

    International Nuclear Information System (INIS)

    Severini, Aldo; Mantero, Sara; Tanzi, Maria Cristina; Cigada, Alberto; Addis, Flaminio; Cozzi, Guido; Salvetti, Monica; Andreola, Salvatore; Motta, Antonella; Regalia, Enrico; Pulvirenti, Andrea; De Pedri, Enrico; Doci, Roberto

    1999-01-01

    Purpose: Prototypes of Gianturco-Rosch Z-stents coated with polycarbonate urethane (PCU) were placed in the biliary tree of pigs, in order to test their biomechanical behavior, stability, and biocompatibility. Methods: The stents were surgically implanted in the common bile duct of three pairs of pigs, which were killed after 1, 3, and 6 months respectively. Explanted livers from pigs of the same race, age, and size were used to provide comparative data. The bile ducts were radiologically and histopathologically examined; the stents were processed and examined by scanning electron microscopy. Results: No complications occurred and the animals showed a normal weight gain. The main bile duct appeared radiologically and macroscopically dilated, but the stents proved to be in place. Histologically, the bile duct epithelium was destroyed, but neither hyperplastic nor inflammatory fibrotic reactions of the wall were evident. Both the metallic structure and the polymeric coating of the stents were intact. A layer of organic material with a maximum thickness of approximately 3 μm was evident on the inner surface of the stents. Conclusion: The present in vivo study demonstrates the biocompatibility, efficacy, and stability of PCU-coated Gianturco-Rosch stents in the biliary environment

  16. A new fully covered metal stent with anti-migration features for the treatment of malignant dysphagia.

    Science.gov (United States)

    Walter, Daisy; van den Berg, Maarten W; van Hooft, Jeanin E; Boot, Henk; Scheffer, Robert C H; Vleggaar, Frank P; Siersema, Peter D

    2014-12-01

    A new esophageal stent with two anti-migration features was developed to minimize migration. The aim of this study was to evaluate the clinical efficacy and safety of this stent in patients with malignant dysphagia. A total of 40 patients with dysphagia due to a malignant obstruction of the esophagus were prospectively enrolled in this cohort study. Stent placement was technically successful in 39 patients (98 %). The median dysphagia-free time after stent placement was 220 days (95 % confidence interval 94 - 345 days). Nine patients (23 %) experienced recurrent dysphagia due to tissue overgrowth (n = 2), stent fracture (n = 1), and partial (n = 5) or complete (n = 1) stent migration. A total of 16 serious adverse events occurred in 14 patients (36 %), with hemorrhage (n = 3) and severe nausea or vomiting (n = 3) being the most common causes. This new stent design was effective for the palliation of malignant dysphagia and had a low rate of recurrent dysphagia. However, despite the anti-migration features, stent migration was still a major cause of recurrent dysphagia. Furthermore, treatment was associated with a high adverse event rate. Dutch Trial Registration (NTR 3313). © Georg Thieme Verlag KG Stuttgart · New York.

  17. Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases.

    Science.gov (United States)

    Tanisaka, Yuki; Ryozawa, Shomei; Kobayashi, Masanori; Harada, Maiko; Kobatake, Tsutomu; Omiya, Kumiko; Iwano, Hirotoshi; Arai, Shin; Nonaka, Kouichi; Mashimo, Yumi

    2018-02-01

    Covered self-expandable metallic stents (CSEMS) may provide palliative drainage for unresectable distal malignant biliary strictures. Laser-cut CSEMS allows easy positioning due to its characteristic of minimal stent shortening. Endoscopic stent removal is sometimes recommended for recurrent biliary obstruction (RBO). However, there are no previous reports of endoscopic removal of laser-cut CSEMS. The current study presents data from 6 patients who were placed a laser-cut CSEMS for unresectable distal malignant biliary strictures, and later endoscopic stent removal was attempted for RBO at the present institute. The duration of stent placement, the procedural success rate, the procedural duration, and accidental complications were evaluated. The mean duration of stent placement was 156±37.9 days (range, 117-205). The procedural success rate was 100%. The mean procedural duration was 11.8±7.5 min (range, 5-24). No complications were reported. Laser-cut CSEMS were safely removed from all patients. The present case report is the first to demonstrate that Endoscopic stent removal of laser-cut CSEMS was safely performed.

  18. The risk of endoleak following stent covering of the internal iliac artery during endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Rajesparan, K.; Partridge, W.; Refson, J.; Abidia, A.; Aldin, Z.

    2014-01-01

    Aim: To investigate the risk of endoleak during endovascular aneurysm repair (EVAR) involving the distal common iliac artery (CIA) when the internal iliac artery (IIA) is covered without prior coil embolization. Materials and methods: Retrospective analysis of 145 (125 men, 20 women) consecutive EVAR cases. Clinical notes and radiological images were reviewed, and data collected on patient demographics, aneurysm morphology, covering of the IIA with or without embolization, presence of endoleaks, and patient symptoms relating to IIA ischaemia. Results: A total of 29 IIAs (10%) were covered in a total of 25 patients. Seven IIAs (24%) were embolized before stent covering (Embolization group), and 22 IIAs (76%) were covered only without embolization (Cover group). There was no statistically significant difference in the mean size of the abdominal aortic aneurysm diameter or CIA diameter between each group. No endoleaks from IIA retrograde filling were found in either group. Conclusion: The results of the present study do not support the traditional view that coverage of the IIA without prior embolization carries a high risk of endoleak, with no endoleaks seen in all 22 cases. Large-scale trials are required. However, the advent of branched-stenting techniques and the emergence of their success in long-term follow-up may preclude the former. - Highlights: • No EVAR endoleaks due to retrograde filling of the internal iliac artery (IIA). • No increased risk of endoleak with stent coverage of the IIA without embolisation. • Current evidence does not support traditional views

  19. Expandable stents.

    Science.gov (United States)

    Nesbitt, J C; Carrasco, H

    1996-05-01

    Expandable metallic stents are effective in selected patients with malignant or benign airway stenoses. When used for malignant lesions, the primary purpose of the stent is to improve the quality of life; stents are usually chosen for palliation of symptoms in recognition of the low likelihood of success for other therapy. For patients with benign stenoses, the stents provide a permanent source of structural support to alleviate the narrowed segment. The advantages of the expandable metallic stents are as follows: (1) they can be inserted through an endotracheal tube or under local anesthesia with relative simplicity under fluoroscopic guidance; (2) they do not impair the drainage of sputum because ciliary movement is not interrupted; (3) over a period of a few weeks, the meshwork is gradually covered with mucosa as the stent becomes incorporated into the airway wall; (4) ventilation usually is not impaired if the metallic mesh stent covers another nonstenosed bronchus, because the interstices of the stent are nonobstructive; and (5) they are dynamic and continue to expand over time, particularly if concurrent treatment achieves an effect on the lesion that caused stenosis. Disadvantages of the expandable stent include (1) they often are only temporarily effective for tracheobronchial stenosis due to intraluminal tumor or granulation tissue, both of which can grow between the wires; (2) they are considered permanent stents because removal is difficult; and (3) they can be poorly positioned during placement or can become displaced by progressive migration after placement, and they cannot be repositioned. A relative contraindication to insertion is an inflammatory process or infection that can predispose to granulation formation, particularly at the points of maximal contact pressure of the stent to the airway mucosa. In the presence of inflammation, it may be better to use a silicone prosthesis until the inflammatory process subsides and fibrosis occurs. Granulation

  20. Covered stents for endovascular repair of iatrogenic injuries of iliac and femoral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kufner, Sebastian, E-mail: kufners@dhm.mhn.de [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Cassese, Salvatore; Groha, Philipp; Byrne, Robert A. [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Schunkert, Heribert; Kastrati, Adnan [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Ott, Ilka; Fusaro, Massimiliano [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany)

    2015-04-15

    Background: The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. A strategy of percutaneous transluminal angioplasty (PTA) with covered stent (CS) may represent a valuable alternative to open surgery. However, systematic evaluations of CS in this setting represent a scientific gap. In the present study, we investigate the procedural and clinical outcomes associated with PTA and CS implantation to repair iatrogenic injuries of peripheral arteries. Methods: All patients undergoing PTA with CS for endovascular repair of iatrogenic injuries of peripheral arteries between August 2010 and July 2013 at our Institution were retrospectively analyzed. The primary endpoint was the technical success. Secondary endpoints were in-hospital mortality and cumulative death, target lesion revascularization (TLR), amputation and major stroke at 12-month follow-up. Results: During the period of observation, a total of 30 patients underwent PTA with either self-expandable (43.3%) or balloon-expandable CS (56.7%) for iatrogenic injuries of peripheral arteries. Injuries consisted of perforation/rupture (76.7%), arteriovenous fistula (16.7%) and pseudoaneurysm (6.7%) of iliac–femoral arteries. Technical success was achieved in all cases. Median follow-up was 409 days [210–907]. The incidence of in-hospital mortality was 10.0%. At 12-month follow-up, the incidence of death, TLR, amputation and major stroke was 20.0%, 17.0%, 3.3% and 6.7%, respectively. Conclusion: The use of covered stents for endovascular repair of iatrogenic injuries of peripheral arteries shows a high technical success and may be alternative to surgery. Further studies with larger populations are needed to confirm these preliminary findings. - Highlights: • The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. • Percutaneous transluminal angioplasty with

  1. Safety and Efficacy of a Fully Covered Self-Expandable Metallic Stent in Benign Airway Stenosis.

    Science.gov (United States)

    Fortin, Marc; Lacasse, Yves; Elharrar, Xavier; Tazi-Mezalek, Rachid; Laroumagne, Sophie; Guinde, Julien; Astoul, Philippe; Dutau, Hervé

    2017-01-01

    The use of self-expandable metallic stents (SEMS) in benign airway disease was the object of a boxed warning from the United States Food and Drug Administration in 2005 due to the risk of stent-related complications and difficulties associated with their removal. Third-generation fully covered SEMS have been commercialized since this warning and theoretically should not present the same difficulties associated with removal as they cannot become embedded in the airway mucosa. We aimed to examine the safety and efficacy of a specific third-generation SEMS, the Silmet stent. We reviewed the records of all patients treated for benign airway stenosis with third-generation Silmet SEMS from January 2011 to December 2015 at the North Hospital of Marseilles, France. Forty SEMS were inserted in 30 patients over this period. Twenty (50.0%) stents were removed because of stent-related complications after a median of 77.0 ± 96.6 days (migration 32.5%, granulation tissue formation 7.5%, subjective intolerance 5.0%, mucus plugging 2.5%, laryngeal edema 2.5%). There were no cases of stent-related mortality. All complications were managed successfully endoscopically. Thirty-six stents (90.0%) were removed successfully after a median of 122.0 ± 113.2 days without any complications. The clinical success rate of stent treatment was 40.7%. Third-generation SEMS are a safe treatment option for complex benign airway stenosis, but complications requiring stent removal are frequent. Further studies are needed to compare the performance of third-generation SEMS and silicone stents in benign airway stenosis. © 2017 S. Karger AG, Basel.

  2. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.

    Science.gov (United States)

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-01-01

    Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  3. [Transjugular intrahepatic portosystemic shunting with covered stents in children: a preliminary study of safety and patency].

    Science.gov (United States)

    Zurera, L J; Espejo, J J; Canis, M; Bueno, A; Vicente, J; Gilbert, J J

    2014-01-01

    To retrospectively analyze the safety and efficacy of transjugular intrahepatic portosystemic shunting (TIPS) using covered stents in children. We present 6 children (mean age, 10.6 years; mean weight, 33.5kg) who underwent TIPS with 8mm diameter Viatorr(®) covered stents for acute (n=4) or recurrent (n=2) upper digestive bleeding that could not be controlled by endoscopic measures. Five of the children had cirrhosis and the other had portal vein thrombosis with cavernous transformation. We analyzed the relapse of upper digestive bleeding, the complications that appeared, and the patency of the TIPS shunt on sequential Doppler ultrasonography or until transplantation. A single stent was implanted in a single session in each child; none of the children died. The mean transhepatic gradient decreased from 16mmHg (range: 12-21mmHg) before the procedure to 9mmHg (range: 1-15mmHg) after TIPS. One patient developed mild encephalopathy, and the girl who had portal vein thrombosis with cavernous transformation developed an acute occlusion of the TIPS that resolved after the implantation of a coaxial stent. Three children received transplants (7, 9, and 10 months after the procedure, respectively), and the patency of the TIPS was confirmed at transplantation. In the three remaining children, patency was confirmed with Doppler ultrasonography 1, 3, and 5 months after implantation. None of the children had new episodes of upper digestive bleeding during follow-up after implantation (mean: 8.1 months). Our results indicate that TIPS with 8mm diameter Viatorr(®) covered stents can be safe and efficacious for the treatment of upper digestive bleeding due to gastroesophageal varices in cirrhotic children; our findings need to be corroborated in larger series. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  4. Effect of antithrombotic agents on the patency of PTFE-Covered stents in the inferior vena cava: An experimental study

    International Nuclear Information System (INIS)

    Makutani, Shiro; Kichikawa, Kimihiko; Uchida, Hideo; Maeda, Munehiro; Konishi, Noboru; Hiasa, Yoshio; Yoshikawa, Tomohiro; Kimura, Yukio

    1999-01-01

    Purpose: To evaluate the efficacy of antithrombotic agents in the prevention of stenosis of polytetrafluororethylene (PTFE)-covered stents in the venous system.Methods: Spiral Z stents covered with PTFE (PTFE-covered stents) were placed in the inferior vena cava (IVC) of 34 dogs. Nineteen dogs, used as a control group, were sacrificed at 2, 4, and 12 weeks. Fifteen dogs, previously given antithrombotic agents [cilostazol (n=5), warfarin potassium (n=5), cilostazol plus warfarin potassium (n=5)] were sacrificed at 4 weeks, and then examined angiographically and histopathologically. The effect of the antithrombotic agents was compared between groups.Results: The patency rate of the antithrombotic agent group was 93% (14/15), which was higher than the control group rate of 63% (12/19). The mean stenosis rate of the patent stent at both ends and at the midportion was lower at 4 weeks in the antithrombotic agent group than in the control group. In particular, the mean stenosis rate in the cilostazol plus warfarin potassium group was significantly lower than the control group (Tukey's test, p < 0.05). The mean neointimal thickness of the patent stent at both ends and at the midportion was thinner at 4 weeks in the antithrombotic agent group than in the control group. In particular, the thickness of the neointima in the cilostazol plus warfarin potassium group was significantly decreased when compared with the control group (Tukey's test p < 0.05). At 4 weeks, endothelialization in the antithrombotic agent group tended to be almost identical to that in the control group.Conclusion: The present study suggests that administration of an antithrombotic agent is an effective way of preventing the stenosis induced by a neointimal thickening of PTFE-covered stents in the venous system.

  5. The effect of stent coating on stent deliverability: direct randomised comparison of drug eluting and bare metal stents using the same stent platform.

    Science.gov (United States)

    Siminiak, Tomasz; Link, Rafał; Wołoszyn, Maciej; Kałmucki, Piotr; Baszko, Artur

    2012-01-01

    There is certain experimental and clinical evidence indicating that the covering of bare metal stents (BMS) with drug eluting polymers to produce drug eluting stents (DES) results in increased stent stiffness and modifies the mechanical properties of the stent platform. In addition, it has been speculated that the mechanical performance of DES, compared to BMS, may be related to the type of polymer used to cover stents. We aimed at evaluating the deliverability of DES with a lactate based biodegradable polymer and BMS in patients with stable coronary artery disease in a prospective randomised study. One hundred eleven consecutive patients (age: 36-77, mean 58.8 years) scheduled for routine angioplasty due to stable coronary disease were randomised to receive BMS (Chopin II(TM), Balton, Poland) or paclitaxel eluting stent (Chopin Luc(TM), Balton, Poland) using the same metal platform. Only patients scheduled for angioplasty using the direct implantation technique of a single stent were randomised. The exclusion criteria included patients 〉 80 years, multivessel disease and reference diameter of the target vessel 〉 3.5 mm. In the BMS group (n = 55; 35 males and 20 females), the mean diameter of implanted stents was 3.09 ± 0.40 and the mean length was 11.37 ± 2.80, whereas in the DES group (n = 56; 34 males and 22 females) the mean stent sizes were 3.02 ± 0.34 and 17.90 ± 7.38 mm, respectively (p 〉 0.05 for length). The groups did not significantly differ regarding the frequency of stent implantation to particular coronary vessels. The direct stenting technique was attempted and failed, leading to the stents' implantation after predilatation in five patients in the BMS group and six patients in the DES group. Failure of stent implantation and subsequent implantation of another stent type was observed in no BMS patients and in one DES patient (NS). Although stent covering with lactate based drug eluting polymer may increase its stiffness, it does not affect

  6. Effectiveness and Safety of Endoscopic Treatment of Benign Biliary Strictures Using a New Fully Covered Self Expandable Metal Stent

    Directory of Open Access Journals (Sweden)

    Mihir S. Wagh

    2013-01-01

    Full Text Available Background. In patients with benign biliary strictures, the use of fully covered self-expandable metal stents (SEMS has been proposed as an alternative to plastic stenting, but high quality prospective data are sparse. This study was performed to evaluate the long-term effectiveness and safety of a new fully covered SEMS for benign biliary strictures. Methods. All consecutive patients with benign biliary strictures were treated with placement of a fully covered SEMS (WallFlex for 6 months. Short- and long-term stricture resolution, adverse events, and ease of stent removal were recorded. Results. 23 patients were enrolled. Stricture etiology was chronic pancreatitis (14, postorthotopic liver transplant (4, idiopathic (4, and biliary stones (1. All ERCPs were technically successful. All stents were successfully removed. Short-term stricture resolution was seen in 22/23 (96% patients. Long-term success was 15/18 (83.3%. All 3 failures were patients with biliary strictures in the setting of chronic calcific pancreatitis. Conclusions. The use of the new SEMS for the treatment of benign biliary strictures led to short-term stricture resolution in the vast majority of patients. Over a long-term followup the success rate appears favorable compared to historical results achieved with multiple plastic stenting, particularly in patients with chronic pancreatitis. The study was registered with ClinicalTrials.gov (NCT01238900.

  7. A case of rectovagino-vesical fistula due to radiation therapy for uterine cancer treated with covered expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsukasa, Shunroh; Okabe, Satoshi; Tanami, Hideaki [Tokyo Medical and Dental Univ. (Japan). School of Medicine] (and others)

    2002-04-01

    A 65-year-old woman had received a panhysterectomy and radiation therapy for a uterine cancer in 1974 and underwent a drainage operation for a peritonitis due to rupture of the bladder associated with radiation cystitis in 1983. A rectovesical fistula was revealed and partial resection of the bladder and rectum was performed in 1996. In 1998, rectovesical fistula recurred and symptom of fecaluria and contact-type dermatitis at perineal region subsequently worsened. In February, 2000, colonoscopy and gastrograffin-enema revealed a giant recto-vagino-vesical fistula. Although we recommended ileostomy, the patient refused our offer. She gave informed consent to our proposal about the insertion of a covered expandable metallic stent (EMS) into the rectum to treat for fecaluria. After insertion of a covered EMS, fecaluria and contact-type dermatitis at perineal region subsequently improved. Three months later, fecaluria appeared again. Finally, seven months later, severe inflammation occurred at perineal and pubic region because of migration of the covered EMS into the bladder, then we removed the covered EMS and performed ileostomy. It is difficult to use the covered EMS treatment for benign rectovesical or rectovaginal fistula for a long term. (author)

  8. A fully covered self-expandable metal stent with antimigration features for benign biliary strictures : a prospective, multicenter cohort study

    NARCIS (Netherlands)

    Walter, Daisy; Laleman, Wim; Jansen, Jeroen M; van Milligen de Wit, A W M; Weusten, Bas L; van Boeckel, Petra G; Hirdes, Meike M; Vleggaar, FP; Siersema, Peter D

    2015-01-01

    BACKGROUND: Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. OBJECTIVE: To evaluate the efficacy of a novel

  9. A fully covered self-expandable metal stent with antimigration features for benign biliary strictures: a prospective, multicenter cohort study

    NARCIS (Netherlands)

    Walter, D.; Laleman, W.; Jansen, J.M.; Milligen de Wit, A.W. van; Weusten, B.L.; Boeckel, P.G. van; Hirdes, M.M.; Vleggaar, F.P.; Siersema, P.D.

    2015-01-01

    BACKGROUND: Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. OBJECTIVE: To evaluate the efficacy of a novel

  10. Efficiency and safety of the intraluminal stent as a treatment malignant obstruction of the digestive tract

    International Nuclear Information System (INIS)

    Yu Xixiang; Si Tongguo; Pan Xiaohui; Yang Hui; Nan Yi; Huang Linfen; Feng Xiaofeng; Mao Aiwu

    2006-01-01

    Objective: To evaluate the efficiency and safety of intraluminal stent as a treatment of malignant obstruction of digestive tract and esophago-bronchial fistula. Methods: In total 71 patients suffered with malignant obstruction or esophago-bronchial fistula were treated with permanent nickel-titanium alloy, partially covered stents. All the procedures were performed under DSA guidance. Inserted via the oral anal access, the stents were placed at the sites of obstructions or the fistulas. Esophagogram or colonogram were done before and post the intervention. The clinical efficiency was assessed by function of swallowing or defecation in follow-up. Results: In 62 patients (96.9%), function of swallowing was restored after the stent was placed in upper digestive tract without drinking triggered coughing. Symptoms were immediately relieved after the stent was placed in sigmoid colon or rectum. Displacement of stents was seen in 2 cases (2.8%); restenosis in 2 (2.8%); hoarse voice was noted in 1 case (1.4%); intense thoracic pain was complained in 2 cases (2.8%); mild pain was noted in 12 cases (16.9%); and massive hemorrhage was complicated in 1 case (1.4%). All complications were successfully controlled after proper treatment. Conclusion: It is an effective, easy and safe method to treat malignant obstruction of digestive tract or esophago-bronchial fistula using partially covered nickel-titanium alloy stent. (authors)

  11. Assessment of safety and efficacy of an indigenous self-expandable fully covered esophageal metal stent for palliation of esophageal cancer.

    Science.gov (United States)

    Padhan, R K; Nongthombam, S K; Venuthurimilli, A; Dhingra, R; Sahni, P; Garg, P K

    2016-01-01

    Patients with unresectable esophageal cancer require palliation for dysphagia. Placement of a self-expandable metal stent (SEMS) is the procedure of choice for palliation of dysphagia. To evaluate the safety and efficacy of an indigenous fully-covered SEMS in patients with esophageal cancer. Eligible patients with unresectable esophageal cancer requiring palliation for dysphagia were included in the study. An indigenous fully covered SEMS of appropriate length was placed under endoscopic and fluoroscopic guidance. Outcome measures assessed were adverse events and improvement in dysphagia. Twenty one patients (mean age 57.71±13.14 years; 17 males) were included. After stenting, dysphagia score decreased from 3.2+0.4 to 0.35+0.74 at 4 weeks. Adverse events included retrosternal pain, respiratory distress and aspiration pneumonia in 12, 2 and 1 patients respectively. Five patients required repeat stenting due to stent migration in 4 (following radiotherapy in 3) and tumour ingrowth in 1. There was primary stent malfunction in one patient. The median survival of patients was 140 (76-199) days, which was higher in those who received radiotherapy. The stent was reasonably safe and effective to relieve dysphagia due to unresectable esophageal cancer.

  12. Long-term outcome of self expandable metal stents for biliary obstruction in chronic pancreatitis.

    Science.gov (United States)

    Waldthaler, Alexander; Schütte, Kerstin; Weigt, Jochen; Kropf, Siegfried; Malfertheiner, Peter; Kahl, Stefan

    2013-01-10

    Insertion of a self-expandable metal stent is still controversial for treatment of benign common bile duct stenosis but can be a valuable alternative to surgical treatment. Aim of our study was to analyze the efficacy of covered and uncovered self-expandable metal stent in patients with chronic pancreatitis and common bile duct stenosis. Twenty patients with common bile duct stenosis due to alcoholic chronic pancreatitis were retrospective analyzed. All patients had advanced chronic pancreatitis, presenting with calcifications in pancreatic head. Uncovered self-expandable metal stent (uSEMS) were used in 11 patients (3 females, 8 males) while in 9 patients (3 females, 6 males) partially covered self-expandable metal stent (cSEMS) were inserted. All patients treated with self-expandable metal stent had contraindications for surgery. Overall mean follow up time was 155 weeks: 206 (52-412) weeks in uSEMS, and 93 (25-233) weeks in cSEMS, respectively. Stent patency was in mean 118 weeks: 159 (44-412) weeks in uSEMS and 67 (25-150) weeks in cSEMS (P=0.019). In the uSEMS group, reintervention was necessary in 5 patients (45%) due to stent obstruction, whereas in the cSEMS group 4 patients (44%) needed reintervention (2 obstructions, 2 migration). Stent migration is an early complication, compared to obstruction (P<0.05), and in cSEMS obstruction occurred significantly earlier compared to uSEMS (P<0.05). Patency of uSEMS was significantly longer compared to partially cSEMS. Available self-expandable metal stent, unfortunately, do not meet the demands on successful treatment of benign common bile duct stenosis.

  13. Post-biliary sphincterotomy bleeding despite covered metallic stent deployment

    Directory of Open Access Journals (Sweden)

    Gianfranco Donatelli

    2016-05-01

    Full Text Available Objectives: Several endoscopic techniques have been proposed for the management of post-sphincterotomy bleeding. Lately, self-expandable metal stents deployment has gained popularity especially as a rescue therapy when other endoscopic techniques fail. Methods-results: We report the case report of a massive post-sphincterotomy bleeding in a patient with a self-expandable metal stent in the biliary tree. Despite the presence of a correctly positioned self-expandable metal stent, a new endoscopic session was required to control the bleeding. Conclusions: Self-expandable metal stent may be useful to manage post-endoscopic sphincterotomy bleeding. However, up to now there is no specifically designed self-expandable metal stent for such complication. Large new designed self-expandable metal stent may be a useful tool for biliary endoscopist.

  14. Fully Covered Metallic Stents for the Treatment of Benign Airway Stenosis

    OpenAIRE

    Dahlqvist, Caroline; Ocak, Sebahat; Gourdin, Maximilien; Dincq, Anne Sophie; Putz, Laurie; d’Odémont, Jean-Paul

    2016-01-01

    Introduction. We herein report our experience with new fully covered self-expanding metallic stents in the setting of inoperable recurrent benign tracheobronchial stenosis. Methods. Between May 2010 and July 2014, 21 Micro-Tech® FC-SEMS (Nanjing Co., Republic of Korea) were placed in our hospital in 16 patients for inoperable, recurrent (after dilatation), and symptomatic benign airway stenosis. Their medical files were retrospectively reviewed in December 2014, with focus on stent’s toleranc...

  15. Successful treatment of an iatrogenic hepatic arteriobiliary fistula with an endobiliary covered stent graft: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hyun; Lee, Su Lim; Ku, Young Mi; Chun, Chang Woo [The Catholic Univ. of Korea, Uijeongbu (Korea, Republic of)

    2012-07-15

    Hepatic arteriobiliary fistula is a rare cause of hemobilia following percutaneous transhepatic biliary drainage for treatment of hilar cholangiocarcinoma. Hemobilia related to arterial injury is resistant to conservative treatment. Therefore, transarterial embolization after confirmation of bleeding vessels on an angiogram is generally considered as the first line of treatment to stop arterial bleeding. However, in high risk situations such as a hepatic infarction by arterial embolization, the endobiliary approach with a covered stent can be considered as an alternative treatment method. The authors report a case of iatrogenic arteriobiliary fistula in a patient with hilar cholangiocarcinoma which was successfully controlled by an endobiliary covered stent graft.

  16. Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents.

    Science.gov (United States)

    Sigler, Matthias; Klötzer, Julia; Quentin, Thomas; Paul, Thomas; Möller, Oliver

    2015-12-01

    Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.

  17. Extensive caustic esophageal stricture in children can be treated by serial dilatations interspersed with silicone-covered nitinol stenting

    Directory of Open Access Journals (Sweden)

    Veronica Alonso

    2016-01-01

    Full Text Available Recurrent esophageal stenosis secondary to caustic ingestion may be challenging to treat. Self-expandable esophageal stents may be an alternative to repetitive endoscopic esophageal dilatation. We report a case of a 2-year-old male child with an extensive esophageal caustic stricture successfully treated using a combination of endoscopic dilatation and stenting. After 5 months of serial balloon dilatations, three nitinol internal silicone covered self-expandable stents were placed through the patient′s gastrostomy spanning the entire esophagus. The stents were positioned using a combination of both endoscopic and fluoroscopic guidance. The procedure was repeated with only one stent 3 months later. A new stricture in the proximal esophagus needed surgical resection and anastomosis, followed by two pneumatic dilatations with progressively longer asymptomatic intervals. The results are promising with the patient able to use his own esophagus; however, this is a single case and optimal stent standing time is still to be determined.

  18. Safety and Efficacy of Percutaneous Biliary Covered Stent Placement in Patients with Malignant Biliary Hilar Obstruction; Correlation with Liver Function

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Hyeran; Choi, Sun Young, E-mail: medmath@hanmail.net [School of Medicine Ewha Womans University, Department of Radiology and Medical Research Institute (Korea, Republic of); Kim, Kyung Ah [St. Vincent’s Hospital, The Catholic University of Korea, Department of Radiology (Korea, Republic of); Ko, Soo Bin [College of Arts and Science Case Western Reserve University, Department of Biology (United States)

    2016-09-15

    PurposeTo estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction.Materials and MethodsFrom March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34–94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan–Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearson correlation coefficient was used to analyze the relationship between patient survival and stent patency.ResultsTechnical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6–224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0–132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child–Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001).ConclusionPercutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting

  19. Safety and Efficacy of Percutaneous Biliary Covered Stent Placement in Patients with Malignant Biliary Hilar Obstruction; Correlation with Liver Function

    International Nuclear Information System (INIS)

    Hyun, Hyeran; Choi, Sun Young; Kim, Kyung Ah; Ko, Soo Bin

    2016-01-01

    PurposeTo estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction.Materials and MethodsFrom March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34–94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan–Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearson correlation coefficient was used to analyze the relationship between patient survival and stent patency.ResultsTechnical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6–224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0–132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child–Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001).ConclusionPercutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting

  20. Safety and efficacy of a fully covered large-diameter self-expanding metal stent for the treatment of upper gastrointestinal perforations, anastomotic leaks, and fistula

    NARCIS (Netherlands)

    van den Berg, M. W.; Kerbert, A. C.; van Soest, E. J.; Schwartz, M. P.; Bakker, C. M.; Gilissen, L. P. L.; van Hooft, J. E.

    2016-01-01

    Upper gastrointestinal perforations, fistula, and anastomotic leaks are severe conditions with high mortality. Temporary endoscopic placement of fully covered self-expanding metal stent (fSEMS) has emerged as treatment option. Stent migration is a major drawback of currently used stents. Migration

  1. Magnetizable stent-grafts enable endothelial cell capture

    Science.gov (United States)

    Tefft, Brandon J.; Uthamaraj, Susheil; Harburn, J. Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

  2. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    Science.gov (United States)

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  3. Covered self-expandable metal stents in pancreatic malignancy regardless of resectability: a new concept validated by a decision analysis.

    Science.gov (United States)

    Kahaleh, M; Brock, A; Conaway, M R; Shami, V M; Dumonceau, J M; Northup, P G; Tokar, J; Rich, T A; Adams, R B; Yeaton, P

    2007-04-01

    The current treatment model for the management of malignant biliary obstruction is to place a plastic stent for unstaged pancreatic cancer. In patients with unresectable disease but a life expectancy of more than 6 months, self-expandable metal stents (SEMS) are favored because of their more prolonged patency. We analyzed the efficacy and cost-effectiveness of covered SEMS (CSEMS) in patients with pancreatic cancer and distal biliary obstruction without regard to surgical resectability. Between March 2001 and March 2005, 101 consecutive patients with obstructive jaundice secondary to pancreatic cancer underwent placement of a CSEMS. Patients with resectable tumor were offered pancreaticoduodenectomy. A model was developed to compare the costs of CSEMS and polyethylene and DoubleLayer stents. A total of 21 patients underwent staging laparoscopy, of whom 16 had a resection (76%). The 85 patients who did not have a resection had a mean survival of 5.9 months (range 1-25 months) and a mean CSEMS patency duration of 5.5 months (range 1-16 months). Life-table analysis demonstrated CSEMS patency rates of 97% at 3 months, 85% at 6 months, and 68% at 12 months. In a cost model that accounted for polyethylene and DoubleLayer stent malfunction and surgical resections, initial CSEMS placement (3177 euros per patient) was a less costly intervention than either DoubleLayer stent placement (3224 euros per patient) or polyethylene stent placement with revision (3570 euros per patient). Covered SEMS are an effective treatment for distal biliary obstructions caused by pancreatic carcinoma. Their prolonged patency and removability makes them an attractive option for biliary decompression, regardless of resectability. The strategy of initial covered SEMS placement might be the most cost-effective strategy in these patients.

  4. EW-7197 eluting nano-fiber covered self-expandable metallic stent to prevent granulation tissue formation in a canine urethral model.

    Directory of Open Access Journals (Sweden)

    Kichang Han

    Full Text Available To evaluate an EW-7197-eluting nanofiber-covered stent (NFCS for suppressing granulation tissue formation after stent placement in a canine urethral model.All experiments were approved by the committee of animal research. A total of 12 NFCSs were placed in the proximal and distal urethras of six dogs. Dogs were divided into two groups with 3 dogs each. The control stent (CS group received NFCSs and the drug stent (DS group received EW-7197 (1000 μg-eluting NFCSs. All dogs were sacrificed 8 weeks after stent placement Histologic findings of the stented urethra were compared using the Mann-Whitney U test.Stent placement was technically successful in all dogs without procedure-related complications. On urethrographic analysis, the mean luminal diameter was significantly larger in the DS group than in the CS group at 4 and 8 weeks after stent placement (all p 0.05.The EW-7197-eluting NFCS is effective and safe for suppressing granulation tissue formation after stent placement in a canine urethral model.

  5. Developement of Spherical Polyurethane Beads

    Institute of Scientific and Technical Information of China (English)

    K. Maeda; H. Ohmori; H. Gyotoku

    2005-01-01

    @@ 1Results and Discussion We established a new method to produce the spherical polyurethane beads which have narrower distribution of particle size. This narrower distribution was achieved by the polyurethane prepolymer which contains ketimine as a blocked chain-extending agent. Firstly, the prepolymer is dispersed into the aqueous solution containing surfactant. Secondaly, water comes into the inside of prepolymer as oil phase. Thirdly, ketimine is hydrolyzed to amine, and amine reacts with prepolymer immediately to be polyurethane.Our spherical polyurethane beads are very suitable for automotive interior parts especially for instrument panel cover sheet producing under the slush molding method, because of good process ability, excellent durability to the sunlight and mechanical properties at low temperature. See Fig. 1 ,Fig. 2 and Fig. 3 (Page 820).

  6. A Multicenter, Prospective Study of a New Fully Covered Expandable Metal Biliary Stent for the Palliative Treatment of Malignant Bile Duct Obstruction

    Directory of Open Access Journals (Sweden)

    Bret T. Petersen

    2013-01-01

    Full Text Available Background and Study Aims. Endoscopic placement of self-expanding metal stents (SEMSs is indicated for palliation of inoperable malignant biliary obstruction. A fully covered biliary SEMS (WallFlex Biliary RX Boston Scientific, Natick, USA was assessed for palliation of extrahepatic malignant biliary obstruction. Patients and Methods. 58 patients were included in this prospective, multicenter series conducted under an FDA-approved IDE. Main outcome measurements included (1 absence of stent occlusion within six months or until death, whichever occurred first and (2 technical success, need for reintervention, bilirubin levels, stent patency, time to stent occlusion, and adverse events. Results. Technical success was achieved in 98% (57/58, with demonstrated acute removability in two patients. Adequate clinical palliation until completion of followup was achievedin 98% (54/55 of evaluable patients, with 1 reintervention due to stent obstruction after 142 days. Mean total bilirubin decreased from 8.9 mg/dL to 1.2 mg/dL at 1 month. Device-related adverse events were limited and included 2 cases of cholecystitis. One stent migrated following radiation therapy. Conclusions. The WallFlex Biliary fully covered stent yielded technically successful placement with uncomplicated acute removal where required, appropriate reduction in bilirubin levels, and low rates of stent migration and occlusion. This SEMS allows successful palliation of malignant extrahepatic biliary obstruction.

  7. Y-shaped endoprosthesis stent. A new device for biliary drainage in malignant obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Hauenstein, K H; Beck, A; Sontheimer, J; Krueger, H J; Salm, R

    1988-05-01

    Biliary decompression in cases of central tumorous biliary obstruction requires surgical or internal/external catheter bypass techniques. The development of a 14-F Y-shaped-polyurethane endoprosthesis stent provides the possibility to drain the left and right biliary system simultaneously. The endoprosthesis is placed by a combination of external transhepatic and endoscopic approach. The tip of the singular choledochal stent segment is placed within the choledochus or duodenum.

  8. Treatment of Painful, Irreparable Partial Meniscal Defects With a Polyurethane Scaffold: Midterm Clinical Outcomes and Survival Analysis.

    Science.gov (United States)

    Dhollander, Aad; Verdonk, Peter; Verdonk, René

    2016-10-01

    A biodegradable polyurethane scaffold was designed to fulfill a challenging clinical need in the treatment of patients with painful, irreparable partial meniscal defects. The use of an acellular polyurethane scaffold for new tissue generation in irreparable, partial meniscal defects provides both midterm pain relief and improved functionality. Case series; Level of evidence, 4. A total of 44 patients with irreparable, partial meniscal defects (29 medial and 15 lateral) were implanted with a polyurethane scaffold in a prospective, single-arm proof-of-principle study with a minimum 5-year follow-up. Clinical outcomes were measured with the visual analog scale (VAS) for pain, International Knee Documentation Committee (IKDC), and Knee injury and Osteoarthritis Outcome Score (KOOS) at baseline and at 2- and 5-year follow-up. Magnetic resonance imaging (MRI) was used to evaluate the meniscal implant and cartilage status of the index compartment. Kaplan-Meier time-to-treatment failure distributions were also performed. Removal of the scaffold, conversion to a meniscal transplant, or unicompartmental/total knee arthroplasty was used as endpoints. Seven patients were lost to follow-up (15.9%). The patients who participated in this study showed significant clinical improvement after surgery (mean [±SD] at baseline, 2 years, and 5 years: 56.2 ± 21.6, 24.6 ± 22.7, and 19.3 ± 26.9, respectively [VAS]; 206.5 ± 79.7, 329.8 ± 108.9, and 333.6 ± 112.2, respectively [total KOOS]). MRI of the scaffolds showed a smaller sized implant when compared with the native meniscus with an irregular surface at 2- and 5-year follow-up. A stable cartilage status of the index compartment at 5-year follow-up was demonstrated in 46.7% of patients compared with the baseline status. During the follow-up period, 62.2% of the implants survived. At final follow-up, 66.7% of the medial scaffolds were still functioning versus 53.8% of the lateral scaffolds. A polyurethane meniscal implant can

  9. Esophageal stenting for benign and malignant disease: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline.

    Science.gov (United States)

    Spaander, Manon C W; Baron, Todd H; Siersema, Peter D; Fuccio, Lorenzo; Schumacher, Brigitte; Escorsell, Àngels; Garcia-Pagán, Juan-Carlos; Dumonceau, Jean-Marc; Conio, Massimo; de Ceglie, Antonella; Skowronek, Janusz; Nordsmark, Marianne; Seufferlein, Thomas; Van Gossum, André; Hassan, Cesare; Repici, Alessandro; Bruno, Marco J

    2016-10-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE), endorsed by the European Society for Radiotherapy and Oncology (ESTRO), the European Society of Digestive Endoscopy (ESDO), and the European Society for Clinical Nutrition and Metabolism (ESPEN). The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations for malignant disease 1 ESGE recommends placement of partially or fully covered self-expandable metal stents (SEMSs) for palliative treatment of malignant dysphagia over laser therapy, photodynamic therapy, and esophageal bypass (strong recommendation, high quality evidence). 2 For patients with longer life expectancy, ESGE recommends brachytherapy as a valid alternative or in addition to stenting in esophageal cancer patients with malignant dysphagia. Brachytherapy may provide a survival advantage and possibly a better quality of life compared to SEMS placement alone. (Strong recommendation, high quality evidence.) 3 ESGE recommends esophageal SEMS placement as the preferred treatment for sealing malignant tracheoesophageal or bronchoesophageal fistula (strong recommendation, low quality evidence). 4 ESGE does not recommend the use of concurrent external radiotherapy and esophageal stent treatment. SEMS placement is also not recommended as a bridge to surgery or prior to preoperative chemoradiotherapy. It is associated with a high incidence of adverse events and alternative satisfactory options such as placement of a feeding tube are available. (Strong recommendation, low quality evidence.) Main recommendations for benign disease 1 ESGE recommends against the use of self-expandable stents (SEMSs) as first-line therapy for the management of benign esophageal strictures because of the potential for adverse events, the availability of alternative therapies, and costs (strong

  10. Evaluation of the Effects of Temporary Covered Nitinol Stent Placement in the Prostatic Urethra: Short-Term Study in the Canine Model

    International Nuclear Information System (INIS)

    Crisostomo, Veronica; Song, Ho Young; Maynar, Manuel; Sun, Fei; Soria, Federico; Lima, Juan Rafael; Yoon, Chang Jin; Uson-Gargallo, Jesus

    2007-01-01

    Purpose. To evaluate the effect of temporary stent placement on the canine prostatic urethra. Methods. Retrievable PTFE-covered nitinol stents were placed in the prostatic urethras of 8 beagle dogs under fluoroscopic guidance. Retrograde urethrography was obtained before and after stenting. Retrograde urethrography and endoscopy were performed 1 and 2 months after deployment. The endoscopic degree of hyperplasia was rated on a scale of 0 to 4 (0 absence, 4 = occlusion). On day 60, stents were removed and urethrography was performed immediately before euthanasia. Pathologic analysis was performed to determine the degree of glandular atrophy, periurethral fibrosis, and urethral dilation. Results. Stent deployment was technically successful in 7 animals, and failed in 1 dog due to a narrow urethral lumen. Complete migration was seen in 2 animals at 1 month, and an additional stent was deployed. On day 30, endoscopy showed slight hyperplasia (grade 1) in 3 animals. On day 60, moderate hyperplasia (grade 2) was evidenced in 4 cases. No impairment of urinary flow was seen during follow-up. Retrieval was technically easy to perform, and was successful in all dogs. The major histologic findings were chronic inflammatory cell infiltrates; prostate glandular atrophy, with a mean value of 1.86 (SD 0.90); periurethral fibrosis, with a mean ratio of 29.37 (SD 10.41); and dilatation of the prostatic urethra, with a mean ratio of 6.75 (SD 3.22). Conclusion. Temporary prostatic stent placement in dogs is safe and feasible, causing marked enlargement of the prostatic urethral lumen. Retrievable covered stents may therefore be an option for bladder outlet obstruction management in men

  11. Application of willis covered stent in the treatment of aneurysms located in the cisternal segment of the internal carotid artery: a pilot comparative study with long-term follow-up results

    International Nuclear Information System (INIS)

    Zhu Yueqi; Li Minghua; Fang Chun; Wang Wu; Zhang Peilei; Cheng Yingsheng; Tan Huaqiao; Wang Jianbo

    2010-01-01

    Objective: Complicated aneurysms located in the cisternal segment of the internal carotid artery(ICA-CSA) present unique therapeutic difficulties. This study is to discuss the feasibility of the Willis stent-graft in treating complicated ICA-CSA by comparing its effect with that of coiling therapy. Methods: Willis covered stents were employed in 19 complicated ICA-CSAs (group A), while coils were used in 17 complicated ICA-CSAs (group B). Follow-up angiography was performed to investigate aneurysm recurrence, endoleak and parent artery (PA) stenosis. Kaplan-Meier curves were constructed to compare the recurrence-free and PA stenosis-free rate in both groups. Results: Total exclusion was immediately achieved in 13 ICA-CSAs and minor endoleaks presented in 5 cases in group A. Total or near-total occlusion was achieved in 7 ICA-CSAs, subtotal occlusion in 8 and partial occlusion in 2 cases in group B after coiling. Acute thrombosis occurred in 1 patient in either group and re-hemorrhage happened in 1 patient after coiling. Follow-up angiography in group A revealed that 16 ICA-CSAs were completely isolated, with two parent arteries showing mild in-stent stenosis. Eighteen months after the procedure, Kaplan-Meier analysis showed that the recurrence-free rate was 93.3% and 50%, while the stenosis-free rate of parent artery was 87.5% and 100% in group A and in Group B, respectively. In group A and group Bthe clinical neurological symptoms were fully recovered in 9 and 9, obviously improved in 3 and 5, unchanged in 2 and 2, and aggravated in one and 0 patients, respectively. Conclusion: The implantation of Willis stent-graft is a feasible endovascular therapy for complicated ICA-CSAs. When the parent artery is very tortuous or when the risk that a main collateral branch may be wrongly covered and occluded is present, the implantation of Willis covered stent can not be taken as the treatment of first choice. (authors)

  12. Nitinol Esophageal Stents: New Designs and Clinical Indications

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Boos, Irene; Vetter, Sylvia; Strohm, Michael; Domschke, Sigurd

    1996-01-01

    Purpose: To evaluate the clinical use of covered and noncovered, knitted nitinol stents in patients presenting new stent indications. Methods: Self-expandable, knitted nitinol stents were implanted in four patients for treatment of dysphagia. In two patients who had malignant strictures and had esophago-respiratory fistulae and in one patient with an esophagocutaneous fistula, polytetrafluoroethylene (PTFE)-covered stents were implanted. One patient received a noncovered stent, but a retrograde approach through a percutaneous endoscopic gastrostomy (PEG) fistula had to be chosen for recanalization of an esophageal occlusion. Two patients received stents for treatment of benign strictures. Results: Recanalization of the stricture and stent implantation were performed under fluoroscopic control without any procedure-related morbidity or mortality. Dysphagia improved in all patients and the esophageal fistulae could be sealed off by covered stents. During a maximum follow-up of 18 months, there was no stent migration or esophageal perforation. Complications observed were stent stenosis due to food impaction (1/4) and benign stent stenosis (2/2). Most complications could be treated by the interventional radiologist. Conclusion: Self-expandable, covered Nitinol stents provide an option for the treatment of dysphagia combined with esophageal fistulae. In combination with interventional radiology techniques, even complex strictures are accessible. For benign strictures, the value of stent treatment has not yet been proven

  13. Szycher's handbook of polyurethanes

    National Research Council Canada - National Science Library

    Szycher, M

    2013-01-01

    "Written as a reference for polyurethane technologists and end users, raw materials suppliers, and students in the field, this second edition covers the technical advances in the field over the past 10 years...

  14. Management of malignant biliary obstruction: Technical and clinical results using an expanded polytetrafluoroethylene fluorinated ethylene propylene (ePTFE/FEP)-covered metallic stent after 6-year experience

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Orgera, Gianluigi; Bezzi, Mario; Rossi, Plinio; Allegritti, Massimiliano; Passariello, Roberto [University of Rome, Department of Radiological Sciences, Rome (Italy)

    2008-05-15

    To evaluate the efficacy and safety of an expanded polytetrafluoroethylene-fluorinated ethylene-propylene (ePTFE/FEP)-covered metallic stent in the management of malignant biliary obstruction. Eighty consecutive patients with malignant common bile duct strictures were treated by placement of 83 covered metallic stents. The stent-graft consists of an inner ePTFE/FEP lining and an outer supporting structure of nitinol wire. Clinical evaluation, assessment of serum bilirubin and liver enzyme levels were analyzed before biliary drainage, before stent-graft placement and during the follow-up period at 1, 3, 6, 9 and 12 months. Technical success was obtained in all cases. After a mean follow-up of 6.9{+-}4.63 months, the 30-day mortality rate was 14.2%. Survival rates were 40% and 20.2% at 6 and 12 months, respectively. Stent-graft patency rates were 95.5%, 92.6% and 85.7% at 3, 6 and 12 months, respectively. Complications occurred in five patients (6.4%); among these, acute cholecystitis was observed in three patients (3.8%). A stent-graft occlusion rate of 9% was observed. The percentage of patients undergoing lifetime palliation (91%) and the midterm patency rate suggest that placement of this ePTFE/FEP-covered stent-graft is safe and highly effective in achieving biliary drainage in patients with malignant strictures of the common bile duct. (orig.)

  15. Endoscopic suture fixation is associated with reduced migration of esophageal fully covered self-expandable metal stents (FCSEMS).

    Science.gov (United States)

    Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan

    2017-09-01

    Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.

  16. [The application of Y-shaped self-expandable covered metal stents in the thoracostomach-airway fistula: a single center, 11 years experience].

    Science.gov (United States)

    Fang, Yi; Li, Tengfei; Han, Xinwei; Wu, Gang; Ren, Jianzhuang; Ren, Kewei; Lu, Huibin; Zhang, Quanhui; Li, Zongming

    2015-08-01

    To investigate the clinical feasibility and efficacy of Y-shaped self-expandable covered metal stents (Y-stents) in the management of thoracostomach-airway fistula. Retrospective analysis was performed for 108 patients treated for thoracostomach-airway fistula with Y-shaped self-expandable coated metal stents between April 2003 and October 2014. Y-stents were designed based on the dimensions of trachea and bronchus and sites of the fistula and then were inserted under DSA monitoring. There were 65 cases with single big Y-stent placement, 26 cases with single small Y-stent placement, 23 cases with double Y-stents placement, and 1 case with 3 Y-stents placement. Stent implantation was successfully accomplished with single manipulation in all patients. Complete occlusion of the fistula was obtained in 104 patients after the primary manipulation, and 4 patients required a secondary manipulation where a double Y-stents was inserted because of failure of primary manipulate. Ninety-two patients completed the follow-up , while 16 were lost. Fifty-nine patients died while 33 were alive with marked improvement in their quality of life. The placement of Y-stents can effectively occlude the thoracostomach-airway fistula in patients who had had the esophageal tumors resected. The technique is not only feasible but reliable to improve the quality of life of the patients.

  17. A US Multicenter Study of Safety and Efficacy of Fully Covered Self-Expandable Metallic Stents in Benign Extrahepatic Biliary Strictures.

    Science.gov (United States)

    Saxena, Payal; Diehl, David L; Kumbhari, Vivek; Shieh, Frederick; Buscaglia, Jonathan M; Sze, Wilson; Kapoor, Sumit; Komanduri, Srinadh; Nasr, John; Shin, Eun Ji; Singh, Vikesh; Lennon, Anne Marie; Kalloo, Anthony N; Khashab, Mouen A

    2015-11-01

    Endoscopic therapy is considered first line for management of benign biliary strictures (BBSs). Placement of plastic stents has been effective but limited by their short-term patency and need for repeated procedures. Fully covered self-expandable metallic stents (FCSEMSs) offer longer-lasting biliary drainage without the need for frequent exchanges. The aim of this study was to assess the efficacy and safety of FCSEMS in patients with BBS. A retrospective review of all patients who underwent ERCP and FCSEMS placement at five tertiary referral US hospitals was performed. Stricture resolution and adverse events related to ERCP and/or stenting were recorded. A total of 123 patients underwent FCSEMS placement for BBS and 112 underwent a subsequent follow-up ERCP. The mean age was 62 years (±15.6), and 57% were males. Stricture resolution occurred in 81% of patients after a mean of 1.2 stenting procedures (mean stent dwell time 24.4 ± 2.3 weeks), with a mean follow-up of 18.5 months. Stricture recurrence occurred in 5 patients, and 3 patients required surgery for treatment of refractory strictures. Stent migration (9.7%) was the most common complication, followed by stent occlusion (4.9%), cholangitis (4.1%), and pancreatitis (3.3%). There was one case of stent fracture during removal, and one stent could not be removed. There was one death due to cholangitis. Majority of BBS can be successfully managed with 1-2 consecutive FCSEMS with stent dwell time of 6 months.

  18. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  19. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  20. Covered versus Uncovered Self-Expandable Metal Stents for Managing Malignant Distal Biliary Obstruction: A Meta-Analysis.

    Science.gov (United States)

    Li, Jinjin; Li, Tong; Sun, Ping; Yu, Qihong; Wang, Kun; Chang, Weilong; Song, Zifang; Zheng, Qichang

    2016-01-01

    To compare the efficacy of using covered self-expandable metal stents (CSEMSs) and uncovered self-expandable metal stents (UCSEMSs) to treat objective jaundice caused by an unresectable malignant tumor. We performed a comprehensive electronic search from 1980 to May 2015. All randomized controlled trials comparing the use of CSEMSs and UCSEMSs to treat malignant distal biliary obstruction were included. The analysis included 1417 patients enrolled in 14 trials. We did not detect significant differences between the UCSEMS group and the CSEMS group in terms of cumulative stent patency (hazard ratio (HR) 0.93, 95% confidence interval (CI) 0.19-4.53; p = 0.93, I2 = 0%), patient survival (HR 0.77, 95% CI 0.05-10.87; p = 0.85, I2 = 0%), overall stent dysfunction (relative ratio (RR) 0.85, M-H, random, 95% CI 0.57-1.25; p = 0.83, I2 = 63%), the overall complication rate (RR 1.26, M-H, fixed, 95% CI 0.94-1.68; p = 0.12, I2 = 0%) or the change in serum bilirubin (weighted mean difference (WMD) -0.13, IV fixed, 95% CI 0.56-0.3; p = 0.55, I2 = 0%). However, we did detect a significant difference in the main causes of stent dysfunction between the two groups. In particular, the CSEMS group exhibited a lower rate of tumor ingrowth (RR 0.25, M-H, random, 95% CI 0.12-0.52; p = 0.002, I2 = 40%) but a higher rate of tumor overgrowth (RR 1.76, M-H, fixed, 95% CI 1.03-3.02; p = 0.04, I2 = 0%). Patients with CSEMSs also exhibited a higher migration rate (RR 9.33, M-H, fixed, 95% CI 2.54-34.24; p = 0.008, I2 = 0%) and a higher rate of sludge formation (RR 2.47, M-H, fixed, 95% CI 1.36-4.50; p = 0.003, I2 = 0%). Our meta-analysis indicates that there is no significant difference in primary stent patency and stent dysfunction between CSEMSs and UCSEMSs during the period from primary stent insertion to primary stent dysfunction or patient death. However, when taking further management for occluded stents into consideration, CSEMSs is a better choice for patients with malignant biliary

  1. MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen

    International Nuclear Information System (INIS)

    Straube, T.; Wolf, S.; Alfke, K.; Jansen, O.; Flesser, A.; Deli, M.; Nabavi, A.

    2005-01-01

    Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. Conclusion: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery. (orig.)

  2. Early and long-term clinical and radiological follow-up results of expanded-polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunt procedures

    International Nuclear Information System (INIS)

    Maleux, Geert; Heye, Sam; Thijs, Maria; Wilms, Guy; Nevens, Frederik; Verslype, Chris; Wilmer, Alexander

    2004-01-01

    The purpose of this study was to assess the therapeutic efficacy and immediate and long-term safety of expanded-tetrafluoroethylene covered stent-grafts for transjugular intrahepatic portosystemic shunts in patients with portal hypertension-related complications. A cohort of 56 patients suffering from severe portal hypertension-related complications underwent implantation of an expanded-polytetrafluoroethylene-covered stent-graft. All patients suffered from severe liver cirrhosis graded Child-Pugh A (n=8; 16%), B (n=13; 21%) or C (n=35; 63%). In 44 patients, the stent-graft was placed during the initial TIPS procedure (de novo TIPS); in the other 12 patients, the stent-graft was placed to repermeabilize the previously placed bare stent (TIPS revision). Follow-up was performed with clinical assessment, duplex ultrasound and, if abnormal or inconclusive, with invasive venography and pressure measurements. Per- en immediate post-procedural complications occurred in four patients (4/56, 7%). None of them was lethal. During follow-up, stent occlusion appeared in one patient and stenosis in two; no recurrence of bleeding was noted in all patients treated for variceal bleeding (n=28), and 24 of the 28 patients (86%) suffering from refractory ascites and/or hepatic hydrothorax were free of regular paracenteses and/or drainage of pleural effusion after shunt creation. The 30-day and global mortality for the total study population (n=56) was, respectively, 7% (n=4) and 28.5% (n=16). In the patient subgroup with variceal bleeding (n=28), 30-day mortality was 3.5% (n=1) and global mortality 14.2% (n=4). In the ascites and/or hydrothorax subgroup (n=28), 8.1% (n=3) mortality at 30 days was found and global mortality was 32.4% (n=12). In 10 patients of the 56 studied patients (18%), isolated hepatic encephalopathy occurred, which was lethal in 4 (Child C) patients (7%). Three of these four patients died within the 1st month after TIPS placement. A very high primary patency rate

  3. Early and long-term clinical and radiological follow-up results of expanded-polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunt procedures

    Energy Technology Data Exchange (ETDEWEB)

    Maleux, Geert; Heye, Sam; Thijs, Maria; Wilms, Guy [University Hospitals Gasthuisberg, Department of Radiology, Leuven (Belgium); Nevens, Frederik; Verslype, Chris [University Hospitals Gasthuisberg, Department of Hepatology, Leuven (Belgium); Wilmer, Alexander [University Hospitals Gasthuisberg, Department of Medical Intensive Care Unit, Leuven (Belgium)

    2004-10-01

    The purpose of this study was to assess the therapeutic efficacy and immediate and long-term safety of expanded-tetrafluoroethylene covered stent-grafts for transjugular intrahepatic portosystemic shunts in patients with portal hypertension-related complications. A cohort of 56 patients suffering from severe portal hypertension-related complications underwent implantation of an expanded-polytetrafluoroethylene-covered stent-graft. All patients suffered from severe liver cirrhosis graded Child-Pugh A (n=8; 16%), B (n=13; 21%) or C (n=35; 63%). In 44 patients, the stent-graft was placed during the initial TIPS procedure (de novo TIPS); in the other 12 patients, the stent-graft was placed to repermeabilize the previously placed bare stent (TIPS revision). Follow-up was performed with clinical assessment, duplex ultrasound and, if abnormal or inconclusive, with invasive venography and pressure measurements. Per- en immediate post-procedural complications occurred in four patients (4/56, 7%). None of them was lethal. During follow-up, stent occlusion appeared in one patient and stenosis in two; no recurrence of bleeding was noted in all patients treated for variceal bleeding (n=28), and 24 of the 28 patients (86%) suffering from refractory ascites and/or hepatic hydrothorax were free of regular paracenteses and/or drainage of pleural effusion after shunt creation. The 30-day and global mortality for the total study population (n=56) was, respectively, 7% (n=4) and 28.5% (n=16). In the patient subgroup with variceal bleeding (n=28), 30-day mortality was 3.5% (n=1) and global mortality 14.2% (n=4). In the ascites and/or hydrothorax subgroup (n=28), 8.1% (n=3) mortality at 30 days was found and global mortality was 32.4% (n=12). In 10 patients of the 56 studied patients (18%), isolated hepatic encephalopathy occurred, which was lethal in 4 (Child C) patients (7%). Three of these four patients died within the 1st month after TIPS placement. A very high primary patency rate

  4. Temporary endoscopic metallic stent for idiopathic esophageal achalasia.

    Science.gov (United States)

    Coppola, Franco; Gaia, Silvia; Rolle, Emanuela; Recchia, Serafino

    2014-02-01

    Idiopathic achalasia is a motor disorder of the esophagus of unknown etiology caused by loss of motor neurons determining an altered motility. It may determine severe symptoms such as progressive dysphagia, regurgitations, and pulmonary aspirations. Many therapeutic options may be offered to patients with achalasia, from surgery to endoscopic treatments such as pneumatic dilation, botulinum injection, peroral endoscopic myotomy, or endoscopic stenting. Recently, temporary placement of a stent was proposed by Cheng as therapy for achalasia disorders, whereas no Western authors have dealt with it up to date. The present study reports our preliminary experience in 7 patients with achalasia treated with a temporary stent. Partially covered self-expanding metallic stents (Micro-Tech, Nanjin, China) 80 mm long and 30 mm wide were placed under fluoroscopic control and removed after 6 days. Clinical follow-up was scheduled to check endoscopic success, symptoms release, and complications. The placement and the removal of the stents were obtained in all patients without complications. Mean clinical follow-up was 19 months. Five out of 7 patients referred total symptoms release and 2 experienced significant improvement of dysphagia. The procedure was not time consuming and was safe; no mild or severe complications were registered. In conclusion, our results may suggest a possible safe and effective endoscopic alternative treatment in patients with achalasia; however, further larger studies are necessary to confirm these promising, but very preliminary, data.

  5. The influence of conditioning film on antifouling properties of the polyurethane film modified by chondroitin sulfate in urine

    Science.gov (United States)

    Yuan, Huihui; Qian, Bin; Chen, Huaying; Lan, Minbo

    2017-12-01

    The encrustation and induced infection severely impact on the therapeutic effectiveness and service life of urinary stents due to the fast formation of conditioning film on urinary stents after implantation. The composition and properties of conditioning film have great influence on antifouling properties of stent materials. In our previous work, we modified polyurethane films by chondroitin sulfate (PU-CS) with different CS grafting densities to verify its anti-fouling properties. To obtain the in-depth understanding of encrustation on urinary stents, we investigated the impact of the composition and properties of conditioning film on the following inorganic salt deposition and bacteria adhesion in urine. The results showed that quantity of proteins and polysaccharides in conditioning films, and the roughness, water contact angle and zeta potential of PU-CSs covered with corresponding conditioning film decreased with the increase of CS grafting density on PU films.PU-CS(3) with highest CS grafting density (3.70 g/cm2) had the highest bacteria inhibition rate and least inorganic salt deposition among the PU-CSs in artificial urine. Moreover, inorganic salts depositing on the PU-CS(3) were less and smaller than those on other films. Bacteria were not detectable until day 21 in real urine. Meanwhile, the pH value was elevated. The results suggested that the component of conditioning films was more important than other surface properties such as hydrophilicity, zeta potential and roughness for inorganic salt deposition and bacteria adhesion. Moreover, the anti-encrustation properties of the surface was promoted by proteins and inhibited by polysaccharides.

  6. Square Stent: A New Self-Expandable Endoluminal Device and Its Applications

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Uchida, Barry; Timmermans, Hans; Keller, Frederick S.; Roesch, Josef

    2001-01-01

    The square stent is a new, simply constructed, self-expanding device that has recently been described. Compared with other stents, the square stent has a minimal amount of metal and thus requires a smaller-diameter catheter for introduction. Despite the small amount of metal present, the square stent has adequate expansile force. We have been evaluating the square stent for various interventional applications. In addition to the basic square stent, combinations of square stents and coverings for square stents were developed and evaluated to expand its uses and indications. One of the coverings tested is a new biomaterial: small intestinal submucosa (SIS). This paper will discuss the various applications of the square stent, which include a retrievable inferior vena cava filter, vascular occluder, graft adapter, and venous and aortic valves. In addition, we will review the important properties of SIS as a covering for the square stent

  7. Self-Expandable Metal Stent for Closure of a Large Leak after Total Gastrectomy

    Directory of Open Access Journals (Sweden)

    G. Curcio

    2010-08-01

    Full Text Available In recent years, self-expandable metallic stents (SEMSs have emerged as a promising treatment alternative for the bridging and sealing of esophageal perforations and extensive anastomotic leaks after esophageal resection or total gastrectomy. A 56-year-old woman underwent a total gastrectomy with Roux-en-Y end-to-side esophagojejunostomy for a gastric signet ring cell carcinoma. Ten days later, esophagogastroduodenoscopy showed a 2 cm fistula in the distal end of the Roux limb of the anastomosis. This was confirmed by gastrografin esophagography. The patient was started on total parenteral nutrition. Having deemed clipping treatment for this fistula unfeasible, we decided to insert a partially silicone-coated SEMS (Evolution Controlled Release Esophageal Stent System, Cook Medical, Winston-Salem, N.C., USA. The stent was removed after ten days. Gastrografin esophagography showed no further contrast extravasation, and esophagogastroduodenoscopy showed closure of the fistula. No clinical complications were observed, and the patient was able to start normal per os nutrition. In conclusion, the treatment of symptomatic leaks in patients who have undergone esophagojejunostomy is challenging, and leakage from the jejunal stump can be a potentially serious complication. In the treatment of leakage after total gastrectomy, plastic stents (which are either too light or exercise too little radial force and totally covered metallic stents may not adhere sufficiently to the esophagojeujunal walls and, as a result, migrate beyond the anastomosis. The promising results of this report suggest that early stenting, using a partially silicone-coated SEMS, is a feasible alternative to surgical treatment in this category of patients.

  8. Use of the covered Y-shaped metallic stent in the treatment of airway stenoses involving the lower trachea and the tracheal carina: preliminary clinical study

    International Nuclear Information System (INIS)

    Yang Ruimin; Li Fenbao; Zhang Mingqiu; Wu Gang; Han Xinwei

    2007-01-01

    Objective: To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina. Methods: The Y-shaped metallic stent delivery system consisted of three-tier structure. The inner-tier was composed of four parallel guiding tubes, which was used for two guidewires and two threads passing through, the middle-tier was delivery catheter, which contained the four guiding tubes, and the outer-tier was introducer sheath. Under the fluoroscopic guidance, 15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents. Results: Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement, and SaO2 was increased form preoperative 75%-89% to postoperative 96%-99%. During follow-up a period of 3-58 weeks (M 22 weeks), all stenosis were resolved without stent-related complications, and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding. Karnofsky performance status (KPS) was improved from preoperative 26%-45% to postoperative 72%-95%. Five patients died of the following causes unrelated to stent insertion: multiple organ failure (n=3), cachexia (n=1) and pulmonary infection caused by gastrobronehial fistula (n=1), and the remaining 10 patients were alive with no evidence of dyspnea at the time of this report. Conclusion: Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal carina was a simple and safe procedure and with a good short-term clinical efficacy. (authors)

  9. Use of the covered Y-shaped metallic stent in the treatment of airway stenoses involving the lower trachea and the tracheal carina: preliminary clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Ruimin, Yang; Fenbao, Li; Mingqiu, Zhang [Department of Intervention, First Affiliated Hospital, Xinxiang Medical Univ., Xinxiang (China); Gang, Wu; Xinwei, Han

    2007-09-15

    Objective: To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina. Methods: The Y-shaped metallic stent delivery system consisted of three-tier structure. The inner-tier was composed of four parallel guiding tubes, which was used for two guidewires and two threads passing through, the middle-tier was delivery catheter, which contained the four guiding tubes, and the outer-tier was introducer sheath. Under the fluoroscopic guidance, 15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents. Results: Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement, and SaO2 was increased form preoperative 75%-89% to postoperative 96%-99%. During follow-up a period of 3-58 weeks (M 22 weeks), all stenosis were resolved without stent-related complications, and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding. Karnofsky performance status (KPS) was improved from preoperative 26%-45% to postoperative 72%-95%. Five patients died of the following causes unrelated to stent insertion: multiple organ failure (n=3), cachexia (n=1) and pulmonary infection caused by gastrobronehial fistula (n=1), and the remaining 10 patients were alive with no evidence of dyspnea at the time of this report. Conclusion: Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal carina was a simple and safe procedure and with a good short-term clinical efficacy. (authors)

  10. Vegetable Oil-Based Hyperbranched Thermosetting Polyurethane/Clay Nanocomposites.

    Science.gov (United States)

    Deka, Harekrishna; Karak, Niranjan

    2009-04-25

    The highly branched polyurethanes and vegetable oil-based polymer nanocomposites have been showing fruitful advantages across a spectrum of potential field of applications. Mesua ferrea L. seed oil-based hyperbranched polyurethane (HBPU)/clay nanocomposites were prepared at different dose levels by in situ polymerization technique. The performances of epoxy-cured thermosetting nanocomposites are reported for the first time. The partially exfoliated structure of clay layers was confirmed by XRD and TEM. FTIR spectra indicate the presence of H bonding between nanoclay and the polymer matrix. The present investigation outlines the significant improvement of tensile strength, scratch hardness, thermostability, water vapor permeability, and adhesive strength without much influencing impact resistance, bending, and elongation at break of the nanocomposites compared to pristine HBPU thermoset. An increment of two times the tensile strength, 6 degrees C of melting point, and 111 degrees C of thermo-stability were achieved by the formation of nanocomposites. An excellent shape recovery of about 96-99% was observed for the nanocomposites. Thus, the formation of partially exfoliated clay/vegetable oil-based hyperbranched polyurethane nanocomposites significantly improved the performance.

  11. Management of pancreatic collections with a novel endoscopically placed fully covered self-expandable metal stent: a national experience (with videos).

    Science.gov (United States)

    Chandran, Sujievvan; Efthymiou, Marios; Kaffes, Arthur; Chen, John Wei; Kwan, Vu; Murray, Michael; Williams, David; Nguyen, Nam Quoc; Tam, William; Welch, Christine; Chong, Andre; Gupta, Saurabh; Devereaux, Ben; Tagkalidis, Peter; Parker, Frank; Vaughan, Rhys

    2015-01-01

    Recent medical literature on novel lumen-apposing stents for the treatment of pancreatic fluid collections (PFCs) is limited by small numbers, solo operators, and single-center experience. To evaluate a recently developed lumen-apposing, fully covered self-expandable metal stent (FCSEMS) in the management of PFCs. Retrospective case series. Thirteen tertiary and private health care centers across Australia. Forty-seven patients (median age 51 years) who underwent endoscopic management of PFCs. Insertion of FCSEMS after PFC puncture under EUS guidance. A subgroup of 9 patients underwent direct endoscopic necrosectomy. Technical and clinical success rate, adverse event rate. The technical success rate was 53 of 54 patients (98.1%), and the initial clinical success rate was 36 of 47 (76.6%), which was sustained for more than 6 months in 34 of 36 (94.4%). Early adverse events included 4 cases (7.4%) of stent migration during direct endoscopic necrosectomy, 4 cases (7.4%) of sepsis, 1 case (1.9%) of bleeding, and 1 case (1.9%) of stent migration into the fistula tract. Late adverse events were 6 (11.1%) spontaneous stent migrations, 3 (5.6%) recurrent stent occlusions, 3 (5.6%) tissue ingrowth/overgrowth, and 2 (3.7%) bleeding into PFC. The majority of stents inserted (48 of 54, 88.9%) and removed (31 of 35, 88.6%) in our study were described by the operator as superior to pigtail stents with regard to ease of use. Retrospective study. Although FCSEMSs are technically easier to insert and remove compared with traditional pigtail stents, there are significant limitations to the widespread use of FCSEMSs in the management of PFCs. These include cost, adverse events, and lower-than-expected resolution rates. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  12. Recanalization of an Occluded Intrahepatic Portosystemic Covered Stent via the Percutaneous Transhepatic Approach

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Chih Yang; Liang, Po Chin [National Taiwan University Hospital, Taipei (China)

    2010-08-15

    A 41-year-old woman with liver cirrhosis had recurrent portal hypertension and bleeding from esophageal varices due to complete occlusion of a previously inserted transjugular intrahepatic portosystemic shunt stent. Because recanalization of the stent by the transjugular approach was unsuccessful, ultrasound-guided entry to the splenic vein and portal vein was used. After catheter-directed intrathrombus thrombolysis, successful opening of the stent was achieved and a stent was placed. We herein report a rare case in which thrombolysis and recanalization of a TIPS stent were performed via a percutaneous transhepatic approach

  13. Future developments in biliary stenting

    Science.gov (United States)

    Hair, Clark D; Sejpal, Divyesh V

    2013-01-01

    Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting. PMID:23837001

  14. Tracheal obstruction caused by an expandable metallic stent: a case of successful removal of the stent.

    Science.gov (United States)

    Okuyama, Hiroomi; Kubota, Akio; Kawahara, Hisayoshi; Oue, Takaharu; Nose, Satoko; Ihara, Toshiyuki

    2005-07-01

    We report a case of tracheal obstruction caused by an expandable metallic stent. A 3-month-old girl with severe tracheomalacia had a placement of a Palmaz stent. At 3 years of age, she developed progressive dyspnea. The CT scan showed tracheal obstruction caused by granulation tissue over the stent. At operation, the stent was found to have penetrated the posterior tracheal wall. Under partial cardiopulmonary bypass, the stent was removed along with the membranous wall of the trachea, and the trachea was reconstructed using slide tracheoplasty. Tracheal obstruction is one of the serious complications caused by an expandable metallic stent. Direct open approach to the trachea under cardiopulmonary bypass is thought to be a safe way to manage this problem.

  15. Reversal of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-Induced Hepatic Encephalopathy Using a Strictured Self-Expanding Covered Stent

    International Nuclear Information System (INIS)

    Cox, Mitchell W.; Soltes, George D.; Lin, Peter H.; Bush, Ruth L.; Lumsden, Alan B.

    2003-01-01

    Hepatic encephalopathy is a known complication following percutaneous transjugular intrahepatic portosystemic shunt (TIPS) placement. We describe herein a simple and effective strategy of TIPS revision by creating an intraluminal stricture within a self-expanding covered stent, which is deployed in the portosystemic shunt to reduce the TIPS blood flow. This technique was successful in reversing a TIPS-induced hepatic encephalopathy in our patient

  16. Effects of 32P radioactive stents on in-stent restenosis in a double stent injury model of the porcine coronary arteries

    International Nuclear Information System (INIS)

    Kim, Han-Soo; Chan, Rosanna C.; Kollum, Marc; Au, Arthur; Tio, Fermin O.; Yazdi, Hamid A.; Ajani, Andrew E.; Waksman, Ron

    2001-01-01

    Background: The major limitation of coronary stenting remains in-stent restenosis, due to the development of neointimal proliferation. Radioactive stents have demonstrated the ability to reduce this proliferation in the healthy nonatherosclerotic porcine animal model. However, inhibition of tissue proliferation in the in-stent restenotic lesion in a porcine model is not well characterized. The objective of this study was to examine the efficacy and safety of the 32 P radioactive stent for the treatment of in-stent restenosis in a double stent injury model of the porcine coronaries. Methods and Materials: Eighteen coronary arteries in 9 pigs underwent nonradioactive stent (8 mm in length) implantation. Thirty days after the initial stent implantation, a 32 P radioactive stent (18 mm in length) with an activity of 0 and 18 μCi was implanted to cover the initial stent. The swine were killed 30 days after the second stent implantation. Histomorphometric analysis was performed for vessel area (VA), stent strut area (SSA), intimal area (IA), and lumen area (LA). Results: Injury scores, VA, SSA, and LA were similar among the control and radiated groups. Neointimal formation was significantly reduced after placement of radioactive stents as compared to control in both the overlapped (0.93±0.12 vs. 1.31±0.51 mm 2 , p 2 , p 32 P radioactive stents may be safe and effective in reducing neointimal formation leading to in-stent restenosis. Longer follow-up will be required to examine whether these positive findings can be maintained

  17. Pseudoaneurysm of the Internal Carotid Artery: Treatment with a Covered Stent

    International Nuclear Information System (INIS)

    Scavee, Vincent; Wispelaere, Jean-Francois de; Mormont, Eric; Coulier, Bruno; Trigaux, Jean-Paul; Schoevaerdts, Jean-Claude

    2001-01-01

    Dissection of the cervical segment of the internal carotid artery may occur spontaneously or after trauma. We report the management of a 53-year-old right-handed man with progressive dizziness and neck pain 6 weeks after a motor vehicle collision. The clinical and neurologic examinations were normal. The CT scan led to the diagnosis of a pseudoaneurysm of the right internal carotid artery near the skull base. We successfully treated this post-traumatic lesion with a covered stent. The patient underwent the endovascular procedure under general anesthesia and transcranial Doppler monitoring. No neurologic event was observed. Obliteration of the pseudoaneurysm with preservation of the carotid artery was achieved. The patient was discharged from the hospital 72 hr later with no complications. Clinical and imaging follow-up at 6 months was unremarkable

  18. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. RESULTS: Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave’s syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. CONCLUSION: The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign

  19. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature.

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-02-16

    To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave's syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and

  20. Vegetable Oil-Based Hyperbranched Thermosetting Polyurethane/Clay Nanocomposites

    Directory of Open Access Journals (Sweden)

    Deka Harekrishna

    2009-01-01

    Full Text Available Abstract The highly branched polyurethanes and vegetable oil-based polymer nanocomposites have been showing fruitful advantages across a spectrum of potential field of applications.Mesua ferreaL. seed oil-based hyperbranched polyurethane (HBPU/clay nanocomposites were prepared at different dose levels by in situ polymerization technique. The performances of epoxy-cured thermosetting nanocomposites are reported for the first time. The partially exfoliated structure of clay layers was confirmed by XRD and TEM. FTIR spectra indicate the presence of H bonding between nanoclay and the polymer matrix. The present investigation outlines the significant improvement of tensile strength, scratch hardness, thermostability, water vapor permeability, and adhesive strength without much influencing impact resistance, bending, and elongation at break of the nanocomposites compared to pristine HBPU thermoset. An increment of two times the tensile strength, 6 °C of melting point, and 111 °C of thermo-stability were achieved by the formation of nanocomposites. An excellent shape recovery of about 96–99% was observed for the nanocomposites. Thus, the formation of partially exfoliated clay/vegetable oil-based hyperbranched polyurethane nanocomposites significantly improved the performance.

  1. Indwelling Stent Embedded with Light-Emitting Diodes for Photodynamic Therapy of Malignant Biliary Obstruction

    International Nuclear Information System (INIS)

    Baran, Timothy M.; Mironov, Oleg; Sharma, Ashwani K.; Foster, Thomas H.

    2016-01-01

    PurposeWe describe the design and preliminary characterization of a stent incorporating light-emitting diodes (LEDs) for photodynamic therapy (PDT) of malignant biliary obstruction.MethodsA prototype was constructed with red (640 nm) LEDs embedded in a 14.5 French polyurethane tube. The device was evaluated for optical power and subjected to physical and electrical tests. PDT-induced reactive oxygen species were imaged in a gel phantom.ResultsThe stent functioned at a 2.5-cm bend radius and illuminated for 6 months in saline. No stray currents were detected, and it was cool after 30 minutes of operation. Optical power of 5–15 mW is applicable to PDT. Imaging of a reactive oxygen indicator showed LED-stent activation of photosensitizer.ConclusionsThe results motivate biological testing and design optimization.

  2. Indwelling Stent Embedded with Light-Emitting Diodes for Photodynamic Therapy of Malignant Biliary Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Baran, Timothy M., E-mail: timothy.baran@rochester.edu [University of Rochester Medical Center, Department of Imaging Sciences (United States); Mironov, Oleg, E-mail: oleg.mironov@uhn.ca [University Health Network, The Joint Department of Medical Imaging (Canada); Sharma, Ashwani K., E-mail: Ashwani-Sharma@URMC.Rochester.edu; Foster, Thomas H., E-mail: thomas.foster@rochester.edu [University of Rochester Medical Center, Department of Imaging Sciences (United States)

    2016-06-15

    PurposeWe describe the design and preliminary characterization of a stent incorporating light-emitting diodes (LEDs) for photodynamic therapy (PDT) of malignant biliary obstruction.MethodsA prototype was constructed with red (640 nm) LEDs embedded in a 14.5 French polyurethane tube. The device was evaluated for optical power and subjected to physical and electrical tests. PDT-induced reactive oxygen species were imaged in a gel phantom.ResultsThe stent functioned at a 2.5-cm bend radius and illuminated for 6 months in saline. No stray currents were detected, and it was cool after 30 minutes of operation. Optical power of 5–15 mW is applicable to PDT. Imaging of a reactive oxygen indicator showed LED-stent activation of photosensitizer.ConclusionsThe results motivate biological testing and design optimization.

  3. COVERED STENTS IN IATROGENIC CORONARY ARTERY FISTULA; A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Masoud Poormoghaddas

    2010-11-01

    Full Text Available Abstract    BACKGROUND: Coronary artery fistula is an abnormal communication between a coronary artery and a cardiac chamber or major cardiac vessels, mostly congenital but some of them are acquired as a consequence of coronary artery perforation.    CASE PRESENTATION: We report a case of cavity spilling coronary artery perforation during percutaneous coronary intervention 7 years ago. Because of continuing symptoms and risk of developing heart failure and pulmonary hypertension we were ought to treat this iatrogenically formed coronary artery fistula. We used stent graft implantation to treat it with acceptable results.    CONCLUSION: Beside their application as a rescue for acute coronary artery perforations, stent grafts can be used with acceptable results in iatrogenically acquired coronary artery coronary artery fistula      Keywords: Coronary artery perforation, Coronary artery fistula, Stent graft.

  4. Flow Velocities After Carotid Artery Stenting: Impact of Stent Design. A Fluid Dynamics Study in a Carotid Artery Model with Laser Doppler Anemometry

    International Nuclear Information System (INIS)

    Greil, Oliver; Kleinschmidt, Thomas; Weiss, Wolfgang; Wolf, Oliver; Heider, Peter; Schaffner, Silvio; Gianotti, Marc; Schmid, Thomas; Liepsch, Dieter; Berger, Hermann

    2005-01-01

    Purpose. To study the influence of a newly developed membrane stent design on flow patterns in a physiologic carotid artery model. Methods. Three different stents were positioned in silicone models of the carotid artery: a stainless steel stent (Wall-stent), a nitinol stent (SelfX), and a nitinol stent with a semipermeable membrane (MembraX). To increase the contact area of the membrane with the vessel wall, another MembranX model was modified at the outflow tract. The membrane consists of a biocompatible silicone-polyurethane copolymer (Elast-Eon) with a pore size of 100 μm. All stents were deployed across the bifurcation and the external carotid artery origin. Flow velocity measurements were performed with laser Doppler anemometry (LDA), using pulsatile flow conditions (Re = 220; flow 0.39 l/min; flow rate ratio ICA:ECA = 70:30) in hemodynamically relevant cross-sections. The hemodynamic changes were analyzed by comparing velocity fluctuations of corresponding flow profiles. Results. The flow rate ratio ICA:ECA shifted significantly from 70/30 to 73.9/26.1 in the MembraX and remained nearly unchanged in the SelfX and Wallstent. There were no changes in the flow patterns at the inflow proximal to the stents. In the stent no relevant changes were found in the SelfX. In the Wallstent the separation zone shifted from the orifice of the ICA to the distal end of the stent. Four millimeters distal to the SelfX and the Wallstent the flow profile returned to normal. In the MembraX an increase in the central slipstreams was found with creation of a flow separation distal to the stent. With a modification of the membrane this flow separation vanished. In the ECA flow disturbances were seen at the inner wall distal to the stent struts in the SelfX and the Wallstent. With the MembraX a calming of flow could be observed in the ECA with a slight loss of flow volume. Conclusions. Stent placement across the carotid artery bifurcation induces alterations of the physiologic flow

  5. A systematic review and meta-analysis of randomized trials and prospective studies comparing covered and bare self-expandable metal stents for the treatment of malignant obstruction in the digestive tract.

    Science.gov (United States)

    Yang, Zhiping; Wu, Qiong; Wang, Fang; Ye, Xiaofei; Qi, Xingshun; Fan, Daiming

    2013-01-01

    Self-expandable metal stents (SEMS) are widely used for the palliative treatment of malignant gastrointestinal obstruction. Our aim was to evaluate the evidence comparing covered and bare SEMS in the digestive tract using meta-analytical techniques. A literature search was performed using PubMed, Cochrane Library, and Embase databases for comparative studies assessing the two types of stents. The primary outcomes of interest were stent patency and patient survival; second outcomes included technical success, clinical success, tumor ingrowth, tumor overgrowth, and stent migration. A random-effects model was conducted. Pooled analysis was done separately based on the different segments of the digestive tract. Eleven studies (8 randomized controlled trials and 3 prospective cohort studies) including a total of 1376 patients were identified. Covered SEMS were equivalent to bare SEMS in terms of technical success, clinical success, stent patency (gastroduodenal obstruction: HR =0.87, 95% CI 0.53-1.42; colorectal obstruction: HR =0.89, 95% CI 0.18-4.45; biliary obstruction: HR =0.73, 95% CI 0.41-1.32) and survival rates (esophageal obstruction: HR =1.80, 95% CI 0.73-4.44; gastroduodenal obstruction: HR =0.83, 95% CI 0.55-1.26; biliary obstruction: HR =0.99, 95% CI 0.77-1.28), although bare stents were more prone to tumor ingrowth (esophageal obstruction: RR =0.10, 95% CI 0.01-0.77; gastroduodenal obstruction: RR =0.12, 95% CI 0.03-0.55; colorectal obstruction: RR =0.21, 95% CI 0.06-0.70; biliary obstruction: RR =0.21, 95% CI 0.06-0.69), whereas covered stents had the higher risk of stent migration (gastroduodenal obstruction: RR =5.01, 95% CI 1.53-16.43; colorectal obstruction: RR =11.70, 95% CI 2.84-48.27; biliary obstruction: RR =8.11, 95% CI 1.47-44.76) and tumor overgrowth (biliary obstruction: RR =2.03, 95% CI 1.08-3.78). Both covered and bare SEMS are comparable in efficacy for the palliative treatment of malignant obstruction in the digestive tract. Each type of

  6. Endotracheal expandable metallic stent placement in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, S; Tanabe, Y; Fujiwara, Y; Koyama, T; Tanigawa, N; Kobayashi, M; Katsube, Y; Nakamura, H [Tottori Univ. School of Medicine, Yonago (Japan). Dept. of Radiology Research Inst. for Microbial Diseases, Osaka (Japan). Dept. of Radiology

    1991-01-01

    Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).

  7. Self-Expandable Metal Stent Placement for Closure of a Leak after Total Gastrectomy for Gastric Cancer: Report on Three Cases and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Dario Raimondo

    2014-01-01

    Full Text Available In the setting of the curative oncological surgery, the gastric surgery is exposed to complicated upper gastrointestinal leaks, and consequently the management of this problem has become more critically focused than was previously possible. We report here three cases of placement of a partially silicone-coated SEMS (Evolution Controlled Release Esophageal Stent System, Cook Medical, Winston-Salem, NC, USA in patients who underwent total gastrectomy with Roux-en-Y end-to-side esophagojejunostomy for a gastric adenocarcinoma. The promising results of our report, despite the small number of patients, suggest that early stenting (through a partially silicone-coated SEMS is a feasible alternative to surgical treatment in this subset of patients. In fact, in the treatment of leakage after total gastrectomy, plastic stents and totally covered metallic stents may not adhere sufficiently to the esophagojejunal walls and, as a result, migrate beyond the anastomosis. However, prospective studies with a larger number of patients might assess the real effectiveness and safety of this procedure.

  8. Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe; Pipitone, Vincenzo; Anselmo, Alessandro; Simonetti, Giovanni

    2005-01-01

    A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence of bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula

  9. Fenestration of a Papyrus PK covered stent to recover the occluded left main bifurcation after sealing a left main perforation during a CTO procedure.

    Science.gov (United States)

    Werner, Gerald S; Ahmed, Waqar H

    2017-09-01

    Covered stents are indicated for coronary perforations, but they may seal off major side branches in that process. We report the successful sealing of an ostial left main perforation, induced by a guide catheter in the course of a retrograde approach to treat a chronic total occlusion (CTO) of the right coronary artery (RCA) in a 76year old woman with prior CABG. The implanted Papyrus covered stent, however, overlapped the left main bifurcation and occluded the non-grafted circumflex artery (CX) resulting in acute ischemia. Through a double lumen catheter advanced over the wire located in the left anterior descending coronary artery (LAD) territory, a stiff recanalization wire could be advanced from the side-port to penetrate the stent membrane towards the CX. This was successfully achieved, and after subsequent dilatation, a drug-eluting stent was implanted in Culotte-fashion from the CX to the left main with subsequent kissing-balloon dilatation. The clinical symptoms subsided immediately, and the RCA was finally recanalized in antegrade parallel wire technique. No periprocedural infarct was observed during 48h of follow-up before discharge. At clinical follow-up of 6months the patient is symptom-free. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Predictors of outcomes in patients undergoing covered and uncovered self-expandable metal stent placement for malignant gastric outlet obstruction: a multicenter study.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-02-01

    Uncovered self-expandable metal stents (U-SEMSs) and covered self-expandable metal stents (C-SEMSs) are available for palliative therapy for malignant gastric outlet obstruction (GOO). However, clinical differences and indications between the 2 types of SEMSs have not been elucidated. We retrospectively compared 126 patients with U-SEMS and 126 patients with C-SEMSs with regard to clinical outcome and factors predictive of clinical improvement after SEMSs placement. No significant difference was observed between the U-SEMS and C-SEMS groups with respect to technical success, clinical success, GOO score, or time to stent dysfunction. Stent migration was significantly more frequent in patients with C-SEMSs (U-SEMSs, .79%; C-SEMSs, 8.73%; P = .005). Karnofsky performance status, chemotherapy, peritoneal dissemination, and stent expansion ≤ 30% were associated significantly with poor GOO score improvement in multivariable analyses, but stent type was not (P = .213). In subgroup analyses, insufficient (≤30%) stent expansion was an independent factor in patients with U-SEMSs (P = .041) but not C-SEMSs. In the insufficient stent expansion subgroup, C-SEMSs was associated significantly with superior clinical improvement compared with U-SEMSs (P = .01). Insufficient stent expansion was observed more frequently in patients with GI obstruction because of anastomotic sites or metastatic cancer (44.8% [13/29], P = .001). No clinical difference, apart from stent migration, was observed between patients with U-SEMSs and C-SEMSs. GI obstruction because of an anastomotic site or metastatic cancer may be an indication for C-SEMS use to improve oral intake after SEMSs placement. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Future developments in biliary stenting

    Directory of Open Access Journals (Sweden)

    Hair CD

    2013-06-01

    Full Text Available Clark D Hair,1 Divyesh V Sejpal21Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA; 2Department of Medicine, Section of Gastroenterology, Hofstra North Shore-LIJ School of Medicine, North Shore University Hospital, Manhasset, NY, USAAbstract: Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.Keywords: plastic stents, self-expandable metal stents, drug eluting stents, bioabsorbable stents, malignant biliary strictures, benign biliary strictures

  12. Self-made Palmaz stent: an experimental swine model study

    International Nuclear Information System (INIS)

    He Shicheng; Teng Gaojun; Guo Jinhe; Fang Wen

    2000-01-01

    Objective: To investigate the histologic changes and physicochemical stability of self-made Palmaz stent placed in swine arteries. Methods: The self-made Palmaz stent was made of 316L stainless steel wire. Nine stents were respectively placed within internal carotid, renal and iliac arteries of six pigs. Pigs were euthanized at intervals of 0.5, 1 and 3 months respectively and angiography were performed. Immediately followed by light and electro scanning microscopy for the stent zones. Results: All stents were successfully implanted in the target arteries and were patent shown in the angiographic examination immediately after the stent placement. Eight stents (8/9) remained patent at the time before euthanasia. No migration of stent were shown in the follow-up angiography. Light and electron scanning microscopy showed that the surface of the stents was covered by a thin layer of endothelial cells 2 weeks after the procedure and completely covered after 4 weeks. No inflammation occurred. Conclusions: The self-made Palmaz stent has good physicochemical stability and histocompatibility with easy placement, rather long term patency, histopathologic stability and thus the promising for clinical application

  13. A Prospective, Multicenter Study of a Novel Mesh-Covered Carotid Stent: The CGuard CARENET Trial (Carotid Embolic Protection Using MicroNet).

    Science.gov (United States)

    Schofer, Joachim; Musiałek, Piotr; Bijuklic, Klaudija; Kolvenbach, Ralf; Trystula, Mariusz; Siudak, Zbigniew; Sievert, Horst

    2015-08-17

    This study sought to evaluate the feasibility of the CGuard Carotid Embolic Protective Stent system-a novel thin strut nitinol stent combined with a polyethylene terephthalate mesh covering designed to prevent embolic events from the target lesion in the treatment of carotid artery lesions in consecutive patients suitable for carotid artery stenting. The risk of cerebral embolization persists throughout the carotid artery stenting procedure and remains during the stent healing period. A total of 30 consecutive patients (age 71.6 ± 7.6 years, 63% male) meeting the conventional carotid artery stenting inclusion criteria were enrolled in 4 centers in Germany and Poland. The primary combined endpoint was the procedure success of the CGuard system and the number and volume of new lesions on the ipsilateral side assessed by diffusion-weighted magnetic resonance imaging at 48 h post-procedure and at 30 days. The secondary endpoint was 30-day major adverse cardiac or cerebrovascular events (death, stroke, or myocardial infarction). Protection devices were used in all procedures. Procedure success was 100%, with 0% procedural complications. The 30-day major adverse cardiac or cerebrovascular events rate was 0%. New ipsilateral ischemic lesions at 48 h occurred in 37.0% of patients and the average lesion volume was 0.039 ± 0.08 cm(3). The 30-day diffusion-weighted magnetic resonance imaging showed complete resolution of all but 1 periprocedural lesion and only 1 new minor (0.116 cm(3)) lesion in relation to the 48-h scan. The use of the CGuard system in patients undergoing carotid artery stenting is feasible. In addition, the benefit of using CGuard may extend throughout the stent healing period. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Evaluation of Silicone as an Endovascular Stent Membrane: In Vivo Canine Studies

    International Nuclear Information System (INIS)

    Fontaine, Arthur B.; Borsa, John J.; Hoffer, Eric; Bloch, Robert; So, Corali

    2001-01-01

    Purpose: Comparative evaluation of the biological effects of a silicone-covered stent versus a bare-metal stent, in an animal model.Methods: Twelve stent implants were placed in the iliac arteries of six adult dogs. Each animal received one 8-mm x 20-mm silicone-covered stent (Permalume; Boston Scientific Vascular, Watertown, MA, USA), in the right iliac artery and one Wallstent (Boston Scientific Vascular) of the same diameter and length in the left iliac artery, during systemic anticoagulation. Angiography was performed before and after implantations. Animals were then allowed to recover and no platelet suppression was given during a 6-week interval, after which the animals were euthanized. The stented arteries were isolated and pressure-fixed in situ with 10% buffered formalin at a pressure of approximately 100 mmHg for a period of 1 hr. Two of 12 stented specimens were opened lengthwise and the luminal surfaces were photographed. Ten of 12 stented arterial segments were encased in methacrylate, then stained with hematoxylin and eosin. Neointimal thickness was quantified on histologic cross-section, for both bare and covered stents. The mean neointimal thicknesses were compared for significant difference using a student t-test.Results: All implants were widely patent at 6-week follow-up angiography. Histologic analysis showed bare metal stents covered by a thin uniform lining of neointima composed of smooth muscle cells in a hyaline matrix (mean thickness of 189 ± 47 μm). Silicone covered stents were devoid of neointima. There was no chronic thrombus or mature endothelium noted anywhere upon the internal silicone surfaces of any of the specimens. There was no foreign body reaction to the silicone cover.Conclusion: Short-term implantation of a silicone-lined Wallstent in canine iliac arteries is well tolerated. Silicone appears to be inert at 6 weeks in this experimental application

  15. Comparison of transjugular intrahepatic portosystemic shunt with covered stent and ballon-occluded retrograde transvenous obliteration in managing isolated gastric varices

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Kwon; Lee, Kristen A.; Sauk, Steven; Korenblat, Kevin [Washington University St. Louis School of Medicine, St. Louis (United States)

    2017-04-15

    Although a transjugular intrahepatic portosystemic shunt (TIPS) is commonly placed to manage isolated gastric varices, balloon-occluded retrograde transvenous obliteration (BRTO) has also been used. We compare the long-term outcomes from these procedures based on our institutional experience. We conducted a retrospective review of patients with isolated gastric varices who underwent either TIPS with a covered stent or BRTO between January 2000 and July 2013. We identified 52 consecutive patients, 27 who had received TIPS with a covered stent and 25 who had received BRTO. We compared procedural complications, re-bleeding rates, and clinical outcomes between the two groups. There were no significant differences in procedural complications between patients who underwent TIPS (7%) and those who underwent BRTO (12%) (p = 0.57). There were also no statistically significant differences in re-bleeding rates from gastric varices between the two groups (TIPS, 7% [2/27]; BRTO, 8% [2/25]; p = 0.94) or in developing new ascites following either procedure (TIPS, 4%; BRTO, 4%; p = 0.96); significantly more patients who underwent TIPS developed hepatic encephalopathy (22%) than did those who underwent BRTO (0%, p = 0.01). There was no statistically significant difference in mean survival between the two groups (TIPS, 30 months; BRTO, 24 months; p = 0.16); median survival for the patients who received TIPS was 16.6 months, and for those who underwent BRTO, it was 26.6 months. BRTO is an effective method of treating isolated gastric varices with similar outcomes and complication rates to those of TIPS with a covered stent but with a lower rate of hepatic encephalopathy.

  16. Treatment of a Ruptured Anastomotic Esophageal Stricture Following Bougienage with a Dacron-Covered Nitinol Stent

    International Nuclear Information System (INIS)

    Heindel, Walter; Gossmann, Axel; Fischbach, Roman; Michel, Olaf; Lackner, Klaus

    1996-01-01

    A patient suffering from esophagorespiratory fistula after bougienage of a benign stricture at the site of the anastomosis between a jejunal interposition and the esophagus was referred for interventional treatment. A prototype nitinol stent centrally covered with Dacron was implanted under regional anesthesia and fluoroscopic guidance. The self-expanding prosthesis dilated the stenosis completely and closed the fistula, with consequent improvement in respiratory and nutritional status and thus the general quality of life. The patient was able to eat and drink normally until death 3 months later due to progression of his underlying malignant disease

  17. Pseudoaneurisme på arteria carotis interna behandlet med stent

    DEFF Research Database (Denmark)

    Benian, Cemil; Wagner, Aase; Cortsen, Marie

    2013-01-01

    Extracranial internal carotid artery aneurysms (EACIAs) are rare. Untreated they have a high stroke rate. Traditionally the treatment has been surgery or endovascular intervention with coils. Both are associated with relatively high complication rates. Another treatment option is endovascular int...... intervention with covered stent, which provides one-step closure of the aneurysm. As in the case story it can be complicated with in-stent occlusion. Therefore we recommend balloon occlusion test before treatment of EACIAs with covered stent....

  18. Argon Plasma Coagulation Combined with Covered Stent Placement for Management of Tracheobronchial Stenoses/occlusions as well as Esophagorespiratory Fistulas

    Directory of Open Access Journals (Sweden)

    Hongwu WANG

    2010-09-01

    Full Text Available Background and objective It is a complex problem and difficult treatment for tracheobronchial stenoses/occlusions involving in carina. The aim of this study is to investigate the feasibility and efficiency of argon plasma coagulation (APC and bifurcated covered Z-type stents (CZTS placement for the treatment of tracheobronchus stenoses and esophagorespiratory fistula (ERF. Methods Thirty-two cases with airway disorders were retrospectively reviewed for the treatment of APC and CZTS placement. Under the bronchoscopic guidance, APC was first given in patients with airway stenoses, then CZTS was placed under the fluoroscopic and flexible bronchoscopic guidance either with airway stenoses or ERF. Results APC was first given in 19 patients with airway stenoses. Airway structures were significantly improved after APC procedure (57.4%-72.1% before APC vs 12.8%-25.8% after APC. Thirty-two CZTS were technically successfully placed in 30 out of 32 cases involving in carinal bifurcation. After APC and stent placement, short breath index was significantly reduced and karnofsky physical score (KPS increased obviously. The endobronchial defects were successfully palliated with bifurcated CZTS placed under fluoroscopy and flexible bronchoscopy in 12 out of 13 patients with ERFs. There is no bleeding introprocedure. Mucous retention was very common in all types of the stents less than 2 weeks after stenting, which required debridement by bronchoscopy and could be prevented by normal saline solution nebulizations. Granuloma developed at the ends of stents after 1 month of stenting which all of them were treated successfully with APC and CO2 cryosurgery. Conclusion Utilization of APC and retrieval bifurcated CZTS placement is a simple and safe protocol for the management of airway complex stenoses involving the tracheal carina and ERF.

  19. Palliative metallic stent placement for managing esophageal cancer of the aging

    International Nuclear Information System (INIS)

    Li Qnqi; Yin Huabin; Yue Wei; Ji Chengzhou; Yang Yufeng

    2000-01-01

    Objective: To evaluate the effectiveness of self-expanding metallic stent in the treatment of the old patients with malignant esophageal stricture. Methods: 32 old patients with malignant esophageal stricture were treated with covered self-expandable metallic stents, 32 stents were placed by X-TV guiding, without pre-dilatation of the stenosis by balloon catheter. Results: All 32 stents were successfully placed, the successful rate was 100%. All of the patients obtained the improvement of the food intake ability. No fatal stent-related complications occurred. The average survival time was 6.5 months. Conclusions: The covered self-expandable metallic stent is effective in the palliative management of malignant esophageal stricture of the aging

  20. Migrated esophageal stent posing a challenge for ventilation

    Directory of Open Access Journals (Sweden)

    Nita D'souza

    2017-01-01

    Full Text Available Self-expandable esophageal stents are being commonly used for palliative treatment in advanced esophageal cancer patients to relieve dysphagia, prevent tracheoesophageal fistula, and facilitate symptomatic betterment. The modern covered stents reduce the ingrowth of the tumor but have seen an increase in the incidence of stent migrations. We report a rather complicated presentation of an esophageal stent for esophageal dilatation and a challenging management of a difficult tracheostomy.

  1. Effective treatment of benign biliary strictures with a removable, fully covered, self-expandable metal stent: A prospective, multicenter European study

    Science.gov (United States)

    Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin

    2016-01-01

    Background Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. Objective The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. Methods We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Results Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Conclusions Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months. PMID:28507752

  2. Effective treatment of benign biliary strictures with a removable, fully covered, self-expandable metal stent: A prospective, multicenter European study.

    Science.gov (United States)

    Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin; Caca, Karel

    2017-04-01

    Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months.

  3. Biodegradable, elastomeric coatings with controlled anti-proliferative agent release for magnesium-based cardiovascular stents.

    Science.gov (United States)

    Gu, Xinzhu; Mao, Zhongwei; Ye, Sang-Ho; Koo, Youngmi; Yun, Yeoheung; Tiasha, Tarannum R; Shanov, Vesselin; Wagner, William R

    2016-08-01

    Vascular stent design continues to evolve to further improve the efficacy and minimize the risks associated with these devices. Drug-eluting coatings have been widely adopted and, more recently, biodegradable stents have been the focus of extensive evaluation. In this report, biodegradable elastomeric polyurethanes were synthesized and applied as drug-eluting coatings for a relatively new class of degradable vascular stents based on Mg. The dynamic degradation behavior, hemocompatibility and drug release were investigated for poly(carbonate urethane) urea (PCUU) and poly(ester urethane) urea (PEUU) coated magnesium alloy (AZ31) stents. Poly(lactic-co-glycolic acid) (PLGA) coated and bare stents were employed as control groups. The PCUU coating effectively slowed the Mg alloy corrosion in dynamic degradation testing compared to PEUU-coated, PLGA-coated and bare Mg alloy stents. This was confirmed by electron microscopy, energy-dispersive x-ray spectroscopy and magnesium ion release experiments. PCUU-coating of AZ31 was also associated with significantly reduced platelet adhesion in acute blood contact testing. Rat vascular smooth muscle cell (rSMC) proliferation was successfully inhibited when paclitaxel was released from pre-loaded PCUU coatings. The corrosion retardation, low thrombogenicity, drug loading capacity, and high elasticity make PCUU an attractive option for drug eluting coating on biodegradable metallic cardiovascular stents. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Characterization of nanostructured ureteral stent with gradient degradation in a porcine model

    Directory of Open Access Journals (Sweden)

    Wang XQ

    2015-04-01

    Full Text Available Xiaoqing Wang,1 Hongli Shan,2 Jixue Wang,1 Yuchuan Hou,1 Jianxun Ding,3 Qihui Chen,1 Jingjing Guan,1 Chunxi Wang,1 Xuesi Chen31Department of Urology, the First Hospital of Jilin University, 2Department of Clinical Laboratory, the First Hospital of Jilin University, 3Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, People’s Republic of ChinaAbstract: A tubular poly(ε-caprolactone (PCL/poly(lactide-co-glycolide (PLGA ureteral stent composed of nanofibers with micropores was fabricated by double-needle electrospinning. The stent was ureteroscopically inserted into six Changbai pigs, and the commercial polyurethane Shagong® stent was inserted into four pigs as control. Intravenous pyelography revealed that the PCL/PLGA stent gradually degraded from the distal end to proximal terminal, and all stents were completely degraded at 10 weeks post-insertion. No significant difference was observed in hydronephrosis severity between the two groups. The levels of serum creatinine and urine pH remained similar throughout the study in the two groups, but the number of white blood cells in the urine was significantly higher in the Shagong® stent group. On Day 70, histological evaluation indicated equivalent histological severity scores in the middle and distal ureter sections and bladder in the two groups. However, the PCL/PLGA stent-implanted pigs had significantly lower mean severity scores in the kidney and proximal ureter sites. These data revealed that the PCL/PLGA stent degraded in a controlled manner, did not induce obstruction, and had a lower urothelial impact in comparison to the Shagong® stent, indicating that the stent exhibited great potential for clinical application.Keywords: nanocomposites, polyesters, poly(ε-caprolactone, poly(lactide-co-glycolide, hydronephrosis severity

  5. Complications of stent placement in patients with esophageal cancer: A systematic review and network meta-analysis.

    Directory of Open Access Journals (Sweden)

    Amin Doosti-Irani

    Full Text Available Palliative treatments and stents are necessary for relieving dysphagia in patients with esophageal cancer. The aim of this study was to simultaneously compare available treatments in terms of complications.Web of Science, Medline, Scopus, Cochrane Library and Embase were searched. Statistical heterogeneity was assessed using the Chi2 test and was quantified by I2. The results of this study were summarized in terms of Risk Ratio (RR. The random effects model was used to report the results. The rank probability for each treatment was calculated using the p-score.Out of 17855 references, 24 RCTs reported complications including treatment related death (TRD, bleeding, stent migration, aspiration, severe pain and fistula formation. In the ranking of treatments, thermal ablative therapy (p-score = 0.82, covered Evolution® stent (p-score = 0.70, brachytherapy (p-score = 0.72 and antireflux stent (p-score = 0.74 were better treatments in the network of TRD. Thermal ablative therapy (p-score = 0.86, the conventional stent (p-score = 0.62, covered Evolution® stent (p-score = 0.96 and brachytherapy (p-score = 0.82 were better treatments in the network of bleeding complications. Covered Evolution® (p-score = 0.78, uncovered (p-score = 0.88 and irradiation stents (p-score = 0.65 were better treatments in network of stent migration complications. In the network of severe pain, Conventional self-expandable nitinol alloy covered stent (p-score = 0.73, polyflex (p-score = 0.79, latex prosthesis (p-score = 0.96 and brachytherapy (p-score = 0.65 were better treatments.According to our results, thermal ablative therapy, covered Evolution® stents, brachytherapy, and antireflux stents are associated with a lower risk of TRD. Moreover, thermal ablative therapy, conventional, covered Evolution® and brachytherapy had lower risks of bleeding. Overall, fewer complications were associated with covered Evolution® stent and brachytherapy.

  6. Complications of stent placement in patients with esophageal cancer: A systematic review and network meta-analysis

    Science.gov (United States)

    Doosti-Irani, Amin; Mansournia, Mohammad Ali; Rahimi-Foroushani, Abbas; Haddad, Peiman

    2017-01-01

    Background Palliative treatments and stents are necessary for relieving dysphagia in patients with esophageal cancer. The aim of this study was to simultaneously compare available treatments in terms of complications. Methods Web of Science, Medline, Scopus, Cochrane Library and Embase were searched. Statistical heterogeneity was assessed using the Chi2 test and was quantified by I2. The results of this study were summarized in terms of Risk Ratio (RR). The random effects model was used to report the results. The rank probability for each treatment was calculated using the p-score. Results Out of 17855 references, 24 RCTs reported complications including treatment related death (TRD), bleeding, stent migration, aspiration, severe pain and fistula formation. In the ranking of treatments, thermal ablative therapy (p-score = 0.82), covered Evolution® stent (p-score = 0.70), brachytherapy (p-score = 0.72) and antireflux stent (p-score = 0.74) were better treatments in the network of TRD. Thermal ablative therapy (p-score = 0.86), the conventional stent (p-score = 0.62), covered Evolution® stent (p-score = 0.96) and brachytherapy (p-score = 0.82) were better treatments in the network of bleeding complications. Covered Evolution® (p-score = 0.78), uncovered (p-score = 0.88) and irradiation stents (p-score = 0.65) were better treatments in network of stent migration complications. In the network of severe pain, Conventional self-expandable nitinol alloy covered stent (p-score = 0.73), polyflex (p-score = 0.79), latex prosthesis (p-score = 0.96) and brachytherapy (p-score = 0.65) were better treatments. Conclusion According to our results, thermal ablative therapy, covered Evolution® stents, brachytherapy, and antireflux stents are associated with a lower risk of TRD. Moreover, thermal ablative therapy, conventional, covered Evolution® and brachytherapy had lower risks of bleeding. Overall, fewer complications were associated with covered Evolution® stent and

  7. Success and complications of an intra-ductal fully covered self-expanding metal stent (ID-FCSEMS) to treat anastomotic biliary strictures (AS) after orthotopic liver transplantation (OLT).

    Science.gov (United States)

    Aepli, Patrick; St John, Andrew; Gupta, Saurabh; Hourigan, Luke F; Vaughan, Rhys; Efthymiou, Marios; Kaffes, Arthur

    2017-04-01

    Anastomotic biliary strictures (AS) after orthotopic liver transplantation (OLT) belong to the most common biliary complications and cause the biggest morbidity burden after OLT. Metal stents for benign biliary strictures are gaining acceptance with many published series. Traditional metal stent designs seem to have poor durability in AS after OLT. Novel intra-ductal stents are showing promise in these strictures. As a result, we designed a special stent with an antimigration waist and a short stent length with a long removal string that rests in the duodenum for easy removal. This is a retrospective multi-centre Australian study of AS after OLT treated with a novel intra-ductal fully covered self-expanding metal stent. From August 2008 to October 2014, records from three liver transplant centres were reviewed. Totally 36 ID-FCSEMS were inserted in 31 cases to treat an AS after OLT. The mean age of the patients was 56 years, and 61 % were male. The mean time of AS presentation after OLT was 20.3 months. Eight out of our 31 patients were previously treated using multiple plastic stenting over time without any success. Treatment with the ID-FCSEMS was performed with an average treatment time of 3.8 months. Stricture resolution was achieved in 100 %. All attempted stents removals were successful without any difficulty. Complications were reported in 6.5 %. It was pleasing that only one case of stent migration (2.8 %) was seen. Follow-up showed seven cases of AS recurrence (24.1 %), and all were treated successfully with repeat ERCP and stenting (some metal, some plastic). This novel ID-FCSEMS has a high clinical success and low complication rate, and in particular, there was only one case of stent migration. As a result, this stent type is preferred to traditional metal stents for treating AS after OLT.

  8. Basic Knowledge about Metal Stent Development

    Directory of Open Access Journals (Sweden)

    Seok Jeong

    2016-03-01

    Full Text Available Biliary self-expandable metal stents (SEMS, a group of non-vascular stents, have been used in the palliative management of biliary obstruction around the world. However, there are still unmet needs in the clinical application of biliary SEMS. Comprehensive understanding of the SEMS is required to resolve the drawbacks and difficulties of metal stent development. The basic structure of SEMS, including the materials and knitting methods of metal wires, covering materials, and radiopaque markers, are discussed in this review. What we know about the physical and mechanical properties of the SEMS is very important. With an understanding of the basic knowledge of metal stents, hurdles such as stent occlusion, migration, and kinking can be overcome to develop more ideal SEMS.

  9. Use of retrievable self-expanding stent in treating childhood benign oesophageal stricture

    International Nuclear Information System (INIS)

    Yu Juming; Fan Guoping; Zhong Weixing; Zhu Ming

    2007-01-01

    Objective: To evaluate the methods and effect of retrievable self-expanding esophageal stent in treating benign esophageal stenosis of children. Methods: The covered retrievable expandable nitinol stents were placed in 10 children with corrosive esophageal stenosis and post-anastomotic stenosis, age ranged from 2 to 12 years, the dysphagia scores were 3, Barium esophagography was taken before the use of retrievable stent. Results: The stents were placed safely in all patients without complications and were successfully removed after all. After the stent placement, all patients could take solid food without dysphagia. During 6 to 12 months follow-up after the stent removal, all children could eat satisfactorily with the dysphagia score as 0. Conclusion: The use of covered retrievable expandable stent is effective and safe in treating childhood benign esophageal stenosis. (authors)

  10. Preoperative biliary drainage using a fully covered self-expandable metallic stent for pancreatic head cancer: A prospective feasibility study.

    Science.gov (United States)

    Togawa, Osamu; Isayama, Hiroyuki; Kawakami, Hiroshi; Nakai, Yousuke; Mohri, Dai; Hamada, Tsuyoshi; Kogure, Hirofumi; Kawakubo, Kazumichi; Sakamoto, Naoya; Koike, Kazuhiko; Kita, Hiroto

    2018-01-01

    The role of endoscopic preoperative biliary drainage (PBD) for pancreatic head cancer is controversial because of the high incidence of stent occlusion before surgery. This study was performed to evaluate the feasibility and safety of PBD using a fully covered self-expandable metallic stent (FCSEMS). This multicenter prospective study involved 26 patients treated for pancreatic head cancer with distal bile duct obstruction from April 2011 to March 2013. An FCSEMS was endoscopically placed in 24 patients. Among these, 7 patients were diagnosed with unresectable cancer, and 17 underwent surgery at a median of 18 days after FCSEMS placement. The main outcome measure was preoperative and postoperative adverse events. Two adverse events (cholecystitis and insufficient resolution of jaundice) occurred between FCSEMS placement and surgery (12%). Postoperative adverse events occurred in eight patients (47%). The cumulative incidence of stent-related adverse events 4 and 8 weeks after FCSEMS placement among the 24 patients who underwent this procedure were 19%. PBD using an FCSEMS is feasible in patients with resectable pancreatic head cancer. Placement of an FCSEMS can be an alternative PBD technique when surgery without delay is impossible. A larger randomized controlled trial is warranted.

  11. Esophageal leiomyoma in a dog causing esophageal distension and treated by transcardial placement of a self-expanding, covered, nitinol esophageal stent.

    Science.gov (United States)

    Robin, Elisabeth M; Pey, Pascaline B; de Fornel-Thibaud, Pauline; Moissonnier, Pierre H M; Freiche, Valérie

    2018-02-01

    CASE DESCRIPTION A 10-year-old spayed female Rottweiler was referred for evaluation because of a 2-month history of regurgitation and weight loss, despite no apparent change in appetite. The dog had received antiemetic and antacid treatment, without improvement. CLINICAL FINDINGS Physical examination revealed a low body condition score (2/5), but other findings were unremarkable. Diffuse, global esophageal dilatation was noted on plain thoracic radiographs, and normal motility was confirmed through videofluoroscopic evaluation of swallowing. Transhepatic ultrasonographic and CT examination revealed a circumferential, intraparietal lesion in the distal portion of the esophagus causing distal esophageal or cardial subobstruction and no metastases. Incisional biopsy of the lesion was performed, and findings of histologic examination supported a diagnosis of esophageal leiomyoma. TREATMENT AND OUTCOME In view of numerous possible complications associated with esophageal surgery, the decision was made to palliatively treat the dog by transcardial placement of a self-expanding, covered, nitinol esophageal stent under endoscopic guidance. Two weeks after stent placement, radiography revealed complete migration of the stent into the gastric lumen. Gastrotomy was performed, and the stent was replaced and fixed in place. Twenty-four months after initial stent placement, the dog had a healthy body condition and remained free of previous clinical signs. CLINICAL RELEVANCE Diffuse benign muscular neoplasia should be considered as a differential diagnosis for acquired esophageal dilatation in adult and elderly dogs. In the dog of this report, transcardial stent placement resulted in resolution of the clinical signs, with no apparent adverse effect on digestive function. The described procedure could be beneficial for nonsurgical treatment of benign esophageal tumors in dogs.

  12. Radiologic placement of metallic esophageal stents: preliminary experience

    International Nuclear Information System (INIS)

    Good, S.; Asch, M.R.; Jaffer, N.; Casson, A.G.

    1997-01-01

    To assess the usefulness of covered, self expanding metallic stents for alleviating stricture associated with malignant esophageal lesions. Patients and methods: Self-expanding metallic stents were placed in 10 patients with dysphagia related to stricture caused by malignant esophageal lesions. The stents were placed fluoroscopically with local anesthesia, and patency of the esophageal lumen was assessed by barium study after the procedure. The patients were then followed clinically. Results: In all 10 cases patency of the lumen was renewed after stent placement. After the procedure 9 of the patients could tolerate a normal or near-normal diet; in the other patient esophageal perforation occurred, and clinical deterioration prevented oral intake of food. In one patient, 2 stents were needed because of the length of the stricture. Two patients experienced reflux after placement of the stent across the gastro-esophageal junction. Another patient had asymptomatic aspiration after stent placement in the proximal esophagus. In 2 patients, symptoms associated with tracheoesophageal fistula were relieved after placement of the stents. Six of the 10 patients died; mean survival after the procedure was 12 (range 1 to 56) weeks. The other 4 patients were alive at the time of writing, having survived for a mean of 7.5 (range 2 to 13) weeks; all of these patients tolerated a near-normal diet. Conclusions: The placement of covered, self-expanding metallic stents is a quick, effective method of palliating dysphagia related to stricture caused by malignant esophageal lesions. (author)

  13. The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Yong Hu; Chung, Jin Wook; Choi, Seung Hong; Kim, Kwang Gi; Kim, Hyo Cheol; So, Young Ho; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-05-15

    To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 {+-} 10.82% (type A) and 13.80 {+-} 6.94% (type B) ({rho} < 0.0001)]. Furthermore, the area ratios of the neointimal hyperplasia per area of stent-wire in the given area were 138.38 {+-} 10.84% (type A). 87.58 {+-} 7.36% (type B) ({rho} = 0.0002). In conclusion the interlacing pattern vs. the crossing pattern showed a higher level of neointimal formation than the crossing pattern.

  14. Stent migration following endoscopic suture fixation of esophageal self-expandable metal stents: a systematic review and meta-analysis.

    Science.gov (United States)

    Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth

    2018-02-01

    Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2  = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2  = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.

  15. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  16. Heparin-bonded covered stents versus bare-metal stents for complex femoropopliteal artery lesions: the randomized VIASTAR trial (Viabahn endoprosthesis with PROPATEN bioactive surface [VIA] versus bare nitinol stent in the treatment of long lesions in superficial femoral artery occlusive disease).

    Science.gov (United States)

    Lammer, Johannes; Zeller, Thomas; Hausegger, Klaus A; Schaefer, Philipp J; Gschwendtner, Manfred; Mueller-Huelsbeck, Stefan; Rand, Thomas; Funovics, Martin; Wolf, Florian; Rastan, Aljoscha; Gschwandtner, Michael; Puchner, Stefan; Ristl, Robin; Schoder, Maria

    2013-10-08

    The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long lesions remains unsatisfactory. In a prospective, randomized, single-blind, multicenter study, 141 patients with symptomatic peripheral arterial disease were assigned to treatment with heparin-bonded, covered stents (Viabahn 72 patients) or BMS (69 patients). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. Mean ± SD lesion length was 19.0 ± 6.3 cm in the Viabahn group and 17.3 ± 6.6 cm in the BMS group. Major complications within 30 days were observed in 1.4%. The 12-month primary patency rates in the Viabahn and BMS groups were: intention-to-treat (ITT) 70.9% (95% confidence interval [CI]: 0.58 to 0.80) and 55.1% (95% CI: 0.41 to 0.67) (log-rank test p = 0.11); treatment per-protocol (TPP) 78.1% (95% CI: 0.65 to 0.86) and 53.5% (95% CI: 0.39 to 0.65) (hazard ratio: 2.23 [95% CI: 1.14 to 4.34) (log-rank test p = 0.009). In lesions ≥20 cm, (TransAtlantic Inter-Society Consensus class D), the 12-month patency rate was significantly longer in VIA patients in the ITT analysis (VIA 71.3% vs. BMS 36.8%; p = 0.01) and the TPP analysis (VIA 73.3% vs. BMS 33.3%; p = 0.004). Freedom from target lesion revascularization was 84.6% for Viabahn (95% CI: 0.72 to 0.91) versus 77.0% for BMS (95% CI: 0.63 to 0.85; p = 0.37). The ankle-brachial index in the Viabahn group significantly increased to 0.94 ± 0.23 compared with the BMS group (0.85 ± 0.23; p stents compared with BMS in lesions ≥20 cm and for all lesions in the TPP analysis. In the ITT analysis for all lesions, which was flawed by major protocol deviations in 8.5% of the patients, the difference was not significant. (GORE VIABAHN® endoprosthesis with bioactive propaten surface versus bare

  17. Endoscopic removal of malfunctioning biliary self-expandable metallic stents.

    Science.gov (United States)

    Familiari, Pietro; Bulajic, Milutin; Mutignani, Massimiliano; Lee, Linda S; Spera, Gianluca; Spada, Cristiano; Tringali, Andrea; Costamagna, Guido

    2005-12-01

    Endoscopic removal of malfunctioning self-expandable metallic biliary stents (SEMS) is difficult and not well described. The aim of this study is to review the indications, the techniques, and the results of SEMS removal in a cohort of patients with malfunctioning stents. All patients who underwent an attempt at endoscopic removal of biliary SEMS over a 5-year period were retrospectively identified. The main indications for SEMS removal were the following: distal migration of the stent or impaction to the duodenum, impaction into the bile-duct wall, tissue ingrowth, and inappropriate length of the stent causing occlusion of intrahepatic ducts. SEMS were removed by using foreign-body forceps or polypectomy snares. Endoscopic removal of 39 SEMS (13 uncovered and 26 covered) was attempted in 29 patients (17 men; mean age, 66 years). SEMS extraction was attempted after a mean of 7.5 months (8.75 months standard deviation) post-SEMS insertion. Removal was successful in 20 patients (68.9%) and in 29 SEMS (74.3%). Covered SEMS were effectively removed more frequently than uncovered ones: 24 of 26 (92.3%) and 5 of 13 (38.4%), respectively (p < 0.05). No major complications were recorded. Multivariate analysis showed that the time interval between insertion and removal, SEMS length, stent-mesh design (zigzag vs. interlaced), and indication for removal were not predictive of success at stent removal. Endoscopic removal of biliary SEMS is feasible and safe in more than 70% of cases. Because only 38% of uncovered SEMS were removable, the presence of a stent covering is the only factor predictive of successful stent extraction. The presence of diffuse and severe ingrowth was the main feature limiting SEMS removal.

  18. The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent

    International Nuclear Information System (INIS)

    Yin, Yong Hu; Chung, Jin Wook; Choi, Seung Hong; Kim, Kwang Gi; Kim, Hyo Cheol; So, Young Ho; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung

    2008-01-01

    To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 ± 10.82% (type A) and 13.80 ± 6.94% (type B) (ρ < 0.0001)]. Furthermore, the area ratios of the neointimal hyperplasia per area of stent-wire in the given area were 138.38 ± 10.84% (type A). 87.58 ± 7.36% (type B) (ρ = 0.0002). In conclusion the interlacing pattern vs. the crossing pattern showed a higher level of neointimal formation than the crossing pattern

  19. Preparation and characterization of polyurethane plasticizer for flexible packaging applications: Natural oils affirmed access

    Directory of Open Access Journals (Sweden)

    Mohammed A. Mekewi

    2017-03-01

    Full Text Available Developing bio-renewable feedstock for polyurethane (PU manufacturing and polymer industry as a whole has become highly desirable for both economic and environmental reasons. In this work castor oil (CO and palm olein (PO polyols were synthesized and partially used as renewable feedstock for the manufacturing of polyurethane plasticizing resin for printing ink applications. The chemical structure of the prepared polyols and polyurethanes were characterized using IR spectra and GPC and their solubility in common solvents was tested. As well, properties such as flexibility, mechanical properties, optical properties, heat seal and freeze resistance of these prepared printing inks were determined. The results indicated that the prepared printing inks from 50% synthesized polyurethane have high thermal stability, adhesion and excellent freeze resistance. The net technical properties of the new ink formulations are relatively comparable to the printing ink prepared from standard polyurethane plasticizer.

  20. Removable fully covered self-expandable metal stents in the treatment of common bile duct strictures due to chronic pancreatitis: a case series

    NARCIS (Netherlands)

    Cahen, D. L.; Rauws, E. A.; Gouma, D. J.; Fockens, P.; Bruno, M. J.

    2008-01-01

    The aim of this study was to test the removability of fully covered self-expandable metal stents (FCSEMS) in patients with a benign common bile duct (CBD) stricture. A FCSEMS was inserted in six patients with a CBD stricture due to chronic pancreatitis who were considered to be unfit for surgery,

  1. Novel biliary self-expanding metal stents: indications and applications.

    Science.gov (United States)

    Blero, Daniel; Huberty, Vincent; Devière, Jacques

    2015-03-01

    Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.

  2. A Flexible Stent with Small Intestinal Submucosa Covering for Direct Intrahepatic Portocaval Shunt: Experimental Pilot Study in Swine

    International Nuclear Information System (INIS)

    Niyyati, Mahtab; Petersen, Bryan D.; Pavcnik, Dusan; Uchida, Barry T.; Timmermans, Hans A.; Hiraki, Takao; Wu Renghong; Brountzos, Elias; Keller, Frederick S.; Roesch, Josef

    2005-01-01

    The suitability of the flexible sandwich Zilver stent-graft (SZSG) with a biologically active tissue layer (small intestinal submucosa) for creation of the intravascular ultrasound (IVUS)-guided direct intrahepatic portocaval shunt (DIPS) was explored in six young swine in a search for a flexible system to replace the rigid polytetrafluoroethylene (PTFE) stent originally used by this group with limited success. The portal vein was punctured from the inferior vena cava through the caudate lobe of the liver using IVUS guidance. After balloon dilation of the puncture tract, DIPS was successfully created in all animals with use of an SZSG 9 mm in diameter and 6 cm or 8 cm long. Only one DIPS remained well patent at 14 days when the animal had to be killed because of encephalopathy. DIPS in the other five animals were found to be either severely stenosed (3 animals) or occluded (2 animals) at 4 weeks due to accelerated formation of neointimal hyperplasia (NIH) in the liver parenchymal portion of the shunt and superimposed thrombosis. The lack of high pressure in the portal system contributed to early endograft closure. The flexible stent and the covering fail badly. The reason for this could be due to either component. More work is required to find a reliable flexible system with long-term patency. Exploration of the IVUS-guided direct extrahepatic portocaval shunt is suggested

  3. Evaluation of the small intestinal submucosa covered stent in preventing restenosis after percutaneous transluminal angioplasty in the swine

    International Nuclear Information System (INIS)

    Wang Xiaobai; Li Jinglei; Zhang Hong; Zhang Yan

    2012-01-01

    Objective: To compare the performance of small intestinal submucosa (SIS)-covered endografts (SCEs) to bare nitinol stents (BSs) in injured swine iliac arteries. Materials and methods: Twenty-eight nitinol stents were used: 14 externally SCEs and 14 BSs. Devices were implanted in each side of balloon-injured external iliac arteries of 14 swine via carotid approach. Arteriograms were obtained before and after implantation and before animal sacrifice at 4, 8, and 12 weeks. Histopathological and electron microscopy studies of explanted specimens were performed. Results: Implantation of all SCEs and BSs was technically successful, but one SCE and one BS were obstructed at 8 weeks after implantation. At sacrifice, the other 26 stents were patent, with angiogram showing no significant different luminal narrowing between SCEs and BSs. Proliferating cell nuclear antigen (PCNA) immunohistochemistry examination revealed that the percentage of PCNA(+) cells were lower in SCEs (p < 0.05). Additionally, histomorphological analysis indicated that the neointima area and percentage of narrowing area were greater in SCEs, but there was no statistical significance. Greater endothelial cell count in SCEs than in BSs per visual field at 4000 times magnification by scanning electron microscope (p < 0.05). Conclusion: Compared to BSs, no definite decrease of neointima and restenosis was found in SCEs in the present study. However, it is effective in promoting endothelial regeneration and strengthening endothelial function.

  4. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    International Nuclear Information System (INIS)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja; Jung, Gyoo Sik

    2005-01-01

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  5. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja [College of Medicine, Kosin University, Busan (Korea, Republic of); Jung, Gyoo Sik [Ulsan Hospital, Ulsan (Korea, Republic of)

    2005-12-15

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  6. Stent placement for benign colonic stenosis: case report, review of the literature, and animal pilot data.

    Science.gov (United States)

    Geiger, Timothy M; Miedema, Brent W; Tsereteli, Zurab; Sporn, Emanuel; Thaler, Klaus

    2008-10-01

    Permanent metal stent placement for malignant intestinal obstruction has been proven to be efficient. Temporary stents for benign conditions of the colon and rectum are less studied. This is a case study, review of the literature, and observation from an animal model on placement of stents in the colorectum for benign disease. A 55-year-old man presented with recurrent obstructions from a benign stricture of the distal sigmoid colon. After failed balloon dilations, a polyester coated stent was placed. The purpose of the stent was to improve symptoms and avoid surgery. The stent was expelled after 5 days. We conducted a literature review of stents placed for benign colorectal strictures and an animal study to evaluate stent migration. In the literature, there were 53 reports of uncovered metal stents, four covered metal stents, and six polyester stents. Patency rates were 71%, and migration rate was 43%. Migration occurred earlier with polyester stents (mean=8 days) versus covered (32 days) or uncovered metal stents (112 days). Severe complications were seen in 23% of patients. Four 45-kg pigs underwent rectosigmoid transection with a 21-mm anastomosis and endoscopic placement of a Polyflex stent. Two stents were secured with suture. Stents without fixation were expelled within 24 h of surgery. Stents with fixation were expelled between postoperative days 2 and 14. Stents for the treatment of benign colorectal strictures are safe, with comparable patency rates between stent types. Metal stents can cause severe complications. In a pig model, covered polyester stents tend to migrate early even with fixation. Further investigation needs to focus on new stent designs and/or better fixation.

  7. Gianturco-Rösch Z stents in tracheobronchial stenoses.

    Science.gov (United States)

    Petersen, B D; Uchida, B T; Barton, R E; Keller, F S; Rösch, J

    1995-01-01

    To evaluate expandable metallic Gianturco-Rösch Z (GRZ) stents for treatment of benign and malignant tracheobronchial stenoses. Six patients, ages 45-73 years, were treated for severe dyspnea with placement of GRZ stents. Three patients had benign tracheal lesions (one tracheomalacia, two postoperative) and received uncovered GRZ stents. Three patients had malignant stenoses at the level of the carina; one received an uncovered stent and the other two received silicone-covered GRZ stents. Two patients with benign lesions responded well to stent placement. One was asymptomatic for a year and then was lost to follow-up; the other improved substantially but died of end-stage lung disease 5 months after stent placement. A third patient with a benign high tracheal lesion did poorly; symptoms recurred secondary to inferior migration of a stent, which was removed surgically at 4 months. All patients with malignant lesions improved symptomatically after stent placement and remained without significant dyspnea until death (from 1 to 6 months). Expandable GRZ stents are promising devices for treatment of benign lesions and offer effective palliation of malignant tracheobronchial stenoses.

  8. Pancreatic Necrosectomy Through a Novel Double-flange Lumen-apposing Covered Metal Stent (Video

    Directory of Open Access Journals (Sweden)

    Andres Sanchez-Yague

    2014-12-01

    A double flange lumen apposing FC-SEMS used as a port for necrosectomy significantly improves management of walled-off pancreatic necrosis. Placement of this stents should be considered when multiple necrosectomy sessions are anticipated. Procedure time can be significantly decreased using a catheter that combines a cautery tip and stent delivery system.

  9. Drug diffusion and biological responses of arteries using a drug-eluting stent with nonuniform coating

    Directory of Open Access Journals (Sweden)

    Saito N

    2016-03-01

    Full Text Available Noboru Saito, Yuhei Mori, Sayaka Uchiyama Terumo Corporation R&D Center, Inokuchi, Nakai-machi, Ashigarakami-gun, Kanagawa, Japan Abstract: The purpose of this study was to determine the effect of a nonuniform coating, abluminal-gradient coating (AGC, which leaves the abluminal surface of the curves and links parts of the stent free from the drug coating, on the diffusion direction of the drug and the biological responses of the artery to drug-eluting stent (DES by comparing the AGC-sirolimus stent and the conventional full-surface coating (CFC sirolimus stent. The study aimed to verify whether the AGC approach was appropriate for the development of a safer DES, minimizing the risks of stent thrombosis due to delayed endothelialization by the drug and distal embolization due to cracking of the coating layer on the hinge parts of the DES on stent expansion. In the in vitro local drug diffusion study, we used rhodamine B as a model drug, and rhodamine B released from the AGC stent diffused predominantly into the abluminal side of the alginate artery model. Conversely, rhodamine B released from the CFC stent quickly spread to the luminal side of the artery model, where endothelial cell regeneration is required. In the biological responses study, the luminal surface of the iliac artery implanted with the AGC-sirolimus stent in a rabbit iliac artery for 2 weeks was completely covered with endothelial-like cells. On the other hand, the luminal surface of the iliac artery implanted with the CFC-sirolimus stent for 2 weeks only showed partial coverage with endothelial-like cells. While thrombosis was observed in two of the three CFC-sirolimus stents, it was observed in only one of the three AGC-sirolimus stents. Taken together, these findings indicate that the designed nonuniform coating (AGC is an appropriate approach to ensure a safer DES. However, the number of studies is limited and a larger study should be conducted to reach a statistically

  10. [Evaluation of stents in treating childhood benign esophageal strictures].

    Science.gov (United States)

    Reinshagen, K; Kähler, G; Manegold, B C; Waag, K-L

    2009-01-01

    Esophageal stenting is a popular of treatment of esophageal strictures in adults. It has also been described for children with benign strictures who did not respond to standard dilatation therapy. The aim of the study was to evaluate weather esophageal stents could be used safely and effectively in the treatment of benign esophageal strictures in children. From 1993 to 2005 stenting therapy was performed in 12 children with complicated esophageal strictures. Etiologies of the strictures were caustic burns in 9 patients, postoperative strictures due to complicated esophageal atresia in 2 patients and iatrogenic esophageal injury in 1 patient. Esophageal silicon tubi, covered retrievable expandable nitinol and plastic stents were placed endoscopically. The clinical course and the long term follow up were evaluated retrospectively The stents and tubi were placed in all patients without complications and were later removed successfully. 6 patients were treated with a self expanding plastic stent. The plastic stents showed a distinct tendency to migrate but in 5/6 patients esophageal stricture was treated successfully. 3 patients were treated by a covered self expanding nitinol stent. No migration occurred. One patient was asymptomatic after therapy, one required further dilatation therapy and the third had esophageal resection. 3 patients were treated by esophageal tubi. 2 patients required surgery in the follow up, one patient is asymptomatic. The use of stenting devices in children to treat benign esophageal strictures is safe and efficient. The self expanding plastic stents had the best long term results but required high compliance of parents and children due to the tendency of stent migration. Self expanding nitinol stents are more traumatic at the extraction procedure and are useful in patients with low compliance. Recurrence of strictures occurred most often after esophageal tubi possibly due to the lack of radial expansion.

  11. Managing burn wounds with SMARTPORE Technology polyurethane foam: two case reports.

    Science.gov (United States)

    Imran, Farrah-Hani; Karim, Rahamah; Maat, Noor Hidayah

    2016-05-12

    Successful wound healing depends on various factors, including exudate control, prevention of microbial contaminants, and moisture balance. We report two cases of managing burn wounds with SMARTPORE Technology polyurethane foam dressing. In Case 1, a 2-year-old Asian girl presented with a delayed (11 days) wound on her right leg. She sustained a thermal injury from a hot iron that was left idle on the floor. Clinical inspection revealed an infected wound with overlying eschar that traversed her knee joint. As her parents refused surgical debridement under general anesthesia, hydrotherapy and wound dressing using SMARTPORE Technology Polyurethane foam were used. Despite the delay in presentation of this linear thermal pediatric burn injury that crossed the knee joint, the patient's response to treatment and its outcome were highly encouraging. She was cooperative and tolerated each dressing change without the need of supplemental analgesia. Her wound was healed by 24 days post-admission. In Case 2, a 25-year-old Asian man presented with a mixed thickness thermal flame burn on his left leg. On examination, the injury was a mix of deep and superficial partial thickness burn, comprising approximately 3% of his total body surface area. SMARTPORE Technology polyurethane foam was used on his wound; his response to the treatment was very encouraging as the dressing facilitated physiotherapy and mobility. The patient rated the pain during dressing change as 2 on a scale of 10 and his pain score remained the same in every subsequent change. His wound showed evidence of epithelialization by day 7 post-burn. There were no adverse events reported. Managing burn wounds with SMARTPORE Technology polyurethane foam resulted in reduced pain during dressing changes and the successful healing of partial and mixed thickness wounds. The use of SMARTPORE Technology polyurethane foam dressings showed encouraging results and requires further research as a desirable management option in

  12. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature.

    Science.gov (United States)

    van Halsema, Emo E; Rauws, Erik A J; Fockens, Paul; van Hooft, Jeanin E

    2015-11-21

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that reported on the clinical success of stent placement for MGOO were included. The primary endpoint was clinical success, defined according to the definition used in the original article. Data were pooled and analyzed using descriptive statistics. Subgroup analyses were performed for partially covered SEMSs (PCSEMSs) and uncovered SEMSs (UCSEMSs) using Fisher's exact test. A total of 19 studies, including 1281 patients, were included in the final analysis. Gastric (42%) and pancreatic (37%) cancer were the main causes of MGOO. UCSEMSs were used in 76% of patients and PCSEMSs in 24%. The overall pooled technical success rate was 97.3% and the clinical success rate was 85.7%. Stent dysfunction occurred in 19.6% of patients, mainly caused by re-obstruction (12.6%) and stent migration (4.3%), and was comparable between PCSEMSs and UCSEMSs (21.2% vs 19.1%, respectively, P = 0.412). Re-obstruction was more common with UCSEMSs (14.9% vs 5.1%, P stent migration was more frequent after PCSEMS placement (10.9% vs 2.2%, P stent patency ranged from 68 to 307 d in five studies. The median overall survival ranged from 49 to 183 d in 13 studies. The clinical outcomes in this large population showed that enteral stent placement was feasible, effective and safe. Therefore, stent placement is a valid treatment option for the palliation of MGOO.

  13. A non-randomized study in consecutive patients with postcholecystectomy refractory biliary leaks who were managed endoscopically with the use of multiple plastic stents or fully covered self-expandable metal stents (with videos).

    Science.gov (United States)

    Canena, Jorge; Liberato, Manuel; Meireles, Liliane; Marques, Inês; Romão, Carlos; Coutinho, António Pereira; Neves, Beatriz Costa; Veiga, Pedro Mota

    2015-07-01

    Endoscopic management of postcholecystectomy biliary leaks is widely accepted as the treatment of choice. However, refractory biliary leaks after a combination of biliary sphincterotomy and the placement of a large-bore (10F) plastic stent can occur, and the optimal rescue endotherapy for this situation is unclear. To compare the clinical effectiveness of the use of a fully covered self-expandable metal stent (FCSEMS) with the placement of multiple plastic stents (MPS) for the treatment of postcholecystectomy refractory biliary leaks. Prospective study. Two tertiary-care referral academic centers and one general district hospital. Forty consecutive patients with refractory biliary leaks who underwent endoscopic management. Temporary placement of MPS (n = 20) or FCSEMSs (n = 20). Clinical outcomes of endotherapy as well as the technical success, adverse events, need for reinterventions, and prognostic factors for clinical success. Endotherapy was possible in all patients. After endotherapy, closure of the leak was accomplished in 13 patients (65%) who received MPS and in 20 patients (100%) who received FCSEMSs (P = .004). The Kaplan-Meier (log-rank) leak-free survival analysis showed a statistically significant difference between the 2 patient populations (χ(2) [1] = 8.30; P stents (P = .024), a plastic stent diameter <20F (P = .006), and a high-grade biliary leak (P = .015) were shown to be significant predictors of treatment failure with MPS. The 7 patients in whom placement of MPS failed were retreated with FCSEMSs, resulting in closure of the leaks in all cases. Non-randomized design. In our series, the results of the temporary placement of FCSEMSs for postcholecystectomy refractory biliary leaks were superior to those from the use of MPS. A randomized study is needed to confirm our results before further recommendations. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  14. A novel, ring-connected stent versus conventional GI stents: comparative study of physical properties and migration rates in a canine colon obstruction model.

    Science.gov (United States)

    Park, Hong Suk; Choo, In Wook; Seo, Soowon; Hyun, Dongho; Lim, Sooyoun; Kim, Jae J; Hong, Saet-Byul; Min, Byung-Hoon; Do, Young Soo; Choo, Sung Wook; Shin, Sung Wook; Park, Kwang Bo; Cho, Sung Ki

    2015-01-01

    Migration of stents is one of the most common adverse events in covered stent placement in GI tract obstruction. To compare physical property and migration rates in a canine colon obstruction model among a novel stent and conventional stents. Comparative physical test and animal study. Medical device testing laboratory and animal laboratory. Mongrel dogs (N=26). Surgical colon obstruction followed by placement of a novel (n=13) or conventional (n=13) stent. Physical properties, migration, and adverse events. The novel stent showed better flexibility, as in a physical test of longitudinal compressibility and axial force, than did conventional stents, and it withstood the fatigue test for 10 days. In terms of radial force and tensile strength, the novel stent showed the same or better results than conventional stents. In a canine colon obstruction model, the migration rate of a novel stent was significantly lower than that of a conventional stent (2/13, 15.4% vs 8/13, 61.5%; P=.008). Animal study of limited size. The novel, ring-connected stent is more flexible and more resistant to migration than the conventional stents. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  15. Endovascular stenting for treatment of complex intracranial aneurysms: preliminary outcome

    International Nuclear Information System (INIS)

    Huang Qinghai; Liu Jianmin; Xu Yi; Hong Bo; Zhao Wenyuan; Zhou Xiaoping

    2004-01-01

    Objective: To summarize the technique and efficiency of combined endovascular stenting and Guglielmi detachable coils (GDC) packing for the treatment of intracranial wide-necked bifurcation aneurysms and recanalized aneurysms. Methods: The coronary stents were implanted across the necks of 5 intracranial wide-necked aneurysms (two at bifurcation of ICA, one at basilar artery and two recanalized PcoA aneurysms). The porous stents covered the ostia of vital side branches and perforating vessels in three cases. Microcatheters were introduced into the aneurysmal sac through the stent mesh and then followed by GDCs embolizing the aneurysms. Results: The stents were deployed in parent artery in all cases. Total occlusion was obtained in 4 cases, while more than 90% in one case with patency of the parent arteries and vital perforating arteries. Follow-up angiography performed in all patients 3-6 months later revealed no intrastent stenosis. All the patients recovered well except III nerve palsy in one patient which diminished 3 months later. Conclusion: Endovaseular therapy combined stent implantation and microcoil placement maybe a valid alteration for the treatment of wide-necked bifurcation aneurysms and recanalized aneurysms, which shows promise clinical application in the future. The ostia of vital side branches covered with stents showed no effect on hemodynamics. (authors)

  16. Treatment Approaches to Urinary Stones Caused by Forgotten DJ Stents

    Directory of Open Access Journals (Sweden)

    Ergun Alma

    2015-03-01

    Full Text Available Ureteral DJ stents have been used widely for years in urology practice. With increased use, complications have been increased and forgotton stents have started to cause problems. The most common complications are early pain and irritative symptoms. Late complications are bacterial colonization and stone formation because of the biofilm covering the stents. Treatment for a forgotten stent varies on many factors, such as stent localization and stone formation. In this article, we aimed to discuss our clinic approach on two different cases in light to current literature. [Cukurova Med J 2015; 40(Suppl 1: 58-63

  17. Neointima development in externally stented saphenous vein grafts

    Directory of Open Access Journals (Sweden)

    Przemysław Węglarz

    2016-11-01

    Full Text Available Introduction : The main limitation of coronary artery bypass grafting (CABG is rapid neointimal hyperplasia leading to graft failure. Aim : To assess plaque formation in saphenous vein grafts (SVG covered by an external Dacron stent in comparison with the classical technique. Material and methods : In the study group vein grafts covered by external stent mesh made of Dacron were implanted. An intravascular ultrasonography (IVUS study was performed in 35 aorto-coronary SVG covered by an external Dacron stent and in 64 normal SVG during the first year after CABG. In each SVG 25 mm of good quality IVUS image, volumes of lumen, plaque (neointima, outer border of the vein graft (external SVG and adventitia were calculated in three time periods: 0–130 days, 130–260 days and 260–390 days. Results : Between the first and second time period, lumen volume (mm3 was reduced from 10.33 ±4.4, to 6.80 ±2.23 in the second period and 5.69 ±1.26 in the third one. This effect was much less marked in normal grafts. The corresponding lumen volume (mm3 was: 10.90 ±3.9, 9.15 ±2.94 and 8.92 ±2.93 in consecutive time periods. Plaque volume (mm3 did not change in control grafts during the course of the study, but it increased very significantly in stented grafts from 0.86 ±1.24 in the first period to 2.70 ±1.58 in the second and 3.29 ±2.66 in the third one. Conclusions : The experimental technique of implanting SVG covered with an external elastic Dacron stent seems to be inferior to traditional ones. This is probably due to the more complicated process of vein implantation and higher micro-injury occurrence during the surgery.

  18. An experimental study on expandable endovascular metallic stents in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Kim, Hak Nam [Chonbuk National University College of Medicine, Chonju (Korea, Republic of)

    1990-12-15

    We constructed an expandable endovascular metallic stent in the same way as Giamturco did. Experiments were made to test the ability of these stents to be used in the vessels. A total of 20 stents were passed through a 8.5 French teflon sheath into the normal abdominal aorta. IVC, and iliac artery of four adult dogs for 4 weeks to 12 weeks; 8 stents (10 mm in diameter fully expanded and 20 mm in length) in the abnormal aorta, 7 stents (12 mm/20 mm) in the IVC, and 5 stents (8 mm/20 mm) in the iliac artery. All but two stents showed no migration, and one complete occlusion occurred in right iliac artery of a dog. Histologically, stents wires were covered by neo-intimal proliferation. The side branches of the main vessels remained patent, even stent wires across their orifices. These metallic stents may be used as an endovascular graft material in the nonsurgical treatment of several forms of vascular disease.

  19. High molecular weight polyurethanes and a polyurethane urea based on 1,4-butanediisocyanate

    NARCIS (Netherlands)

    Spaans, CJ; de Groot, JH; Dekens, FG; Pennings, AJ

    New biomedical polyurethanes and a polyurethane urea based on epsilon-caprolactone and 1,4-butanediisocyanate have been developed. On degradation, only non-toxic products are produced. The polyurethane urea with poly(epsilon-caprolactone) soft segments and butanediisocyanate/butanediamine hard

  20. Comparative analysis of intraluminal radiation stent in treatment of advanced esophageal carcinoma

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; He Shicheng; Fang Wen; Deng Gang; Li Guozhao

    2007-01-01

    Objective: To compare the clinical effectiveness of intraluminal radiation stent with that of common covered stent to palliate dysphagia in advanced esophageal cancer. Methods: Fifty three cases were randomly assigned to the experimental group (Group A, n=27) and the control group (Group B, n26). Radiation stents were placed in Group A and common covered stents were placed in Group B. A randomized trial was performed to compare the two groups with respect to complications, relief of dysphagia, and overall survival period. Results: The placement of stents were successful in all the 53 patients. In Group A, no leakage of radiation source was observed through ECT examination, and no displacement of radiation seeds was found through radiography. The follow-up CT showed reduced lesion size compared to presurgical lesion. Three of the 5 patients who underwent uncovered radiation stent placement showed complete necrosis and inflammatory hyperblastosis in tumor tissue adjacent to radiation particles at 2 months follow-up. The lumen of the stents were smooth and had no overgrowth of tumor tissue. Granulation hyperplasia was found at both ends of the stents, prominent at the proximal ends, The incidence of stent- related complications had no significant difference between group A and group B (test, P>0.05). Dysphasia resolved significantly after stent placement in both groups. The improvement of dysphasia was more significant in Group A than in Group B after 2 months of stent placement (1.37±0.56 in group A, 1.82±0.50 in group B,P=0.004). The median survival period was longer in Group A than in Group B (7 months vs 4 months ). The mean survival period was also longer in Group A than in Group B (8.3 months vs 3.5 months). There was a statistically significant difference in the survival period between the two groups (P<0.01). Conclusion: Intraluminal radiation esophageal stent can not only palliate dysphagia but also restrain tumor growth. Palliation period of dysphagia and

  1. Polyurethane coating with thin polymer films produced by plasma polymerization of diglyme

    International Nuclear Information System (INIS)

    Ribeiro, M A; Ramos, A S; Manfredini, M I; Alves, H A; Ramos, E C T; Honda, R Y; Kostov, K G; Lucena, E F; Mota, R P; Algatti, M A; Kayama, M E

    2009-01-01

    Aqueous-based polyurethane dispersions have been widely utilized as lubricants in textile, shoes, automotive, biomaterial and many other industries because they are less aggressive to surrounding environment. In this work thin films with different thickness were deposited on biocompatible polyurethane by plasma polymerization process using diethylene glycol dimethyl ether (Diglyme) as monomer. Molecular structure of the films was analyzed by Fourier Transform Infrared spectroscopy. The spectra exhibited absorption bands of O-H (3500-3200cm -1 ), C-H (3000-2900cm -1 ), C=O (1730-1650cm -1 ), C-O and C-O-C bonds at 1200-1600cm -1 . The samples wettability was evaluated by measurements of contact angle using different liquids such as water, glycerol, poly-ethane and CMC. The polyurethane surface showed hydrophilic behavior after diglyme plasma-deposition with contact angle dropping from 85 deg. to 22 deg. Scanning Electron Microscopy revealed that diglyme films covered uniformly the polyurethane surfaces ensuring to it a biocompatible characteristic.

  2. Polyurethane coating with thin polymer films produced by plasma polymerization of diglyme

    Science.gov (United States)

    Ribeiro, M. A.; Ramos, A. S.; Manfredini, M. I.; Alves, H. A.; Y Honda, R.; Kostov, K. G.; Lucena, E. F.; Ramos, E. C. T.; Mota, R. P.; Algatti, M. A.; Kayama, M. E.

    2009-05-01

    Aqueous-based polyurethane dispersions have been widely utilized as lubricants in textile, shoes, automotive, biomaterial and many other industries because they are less aggressive to surrounding environment. In this work thin films with different thickness were deposited on biocompatible polyurethane by plasma polymerization process using diethylene glycol dimethyl ether (Diglyme) as monomer. Molecular structure of the films was analyzed by Fourier Transform Infrared spectroscopy. The spectra exhibited absorption bands of O-H (3500-3200cm-1), C-H (3000-2900cm-1), C=O (1730-1650cm-1), C-O and C-O-C bonds at 1200-1600cm-1. The samples wettability was evaluated by measurements of contact angle using different liquids such as water, glycerol, poly-ethane and CMC. The polyurethane surface showed hydrophilic behavior after diglyme plasma-deposition with contact angle dropping from 85° to 22°. Scanning Electron Microscopy revealed that diglyme films covered uniformly the polyurethane surfaces ensuring to it a biocompatible characteristic.

  3. Polyurethane coating with thin polymer films produced by plasma polymerization of diglyme

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, M A; Ramos, A S; Manfredini, M I; Alves, H A; Ramos, E C T [UNIVAP, Sao Jose dos Campos, SP (Brazil); Honda, R Y; Kostov, K G; Lucena, E F; Mota, R P; Algatti, M A; Kayama, M E, E-mail: rmota@feg.unesp.b [FEG-DFQ-UNESP, Av. Ariberto Pereira da Cunha 333, 12516-410 - Guaratingueta, SP (Brazil)

    2009-05-01

    Aqueous-based polyurethane dispersions have been widely utilized as lubricants in textile, shoes, automotive, biomaterial and many other industries because they are less aggressive to surrounding environment. In this work thin films with different thickness were deposited on biocompatible polyurethane by plasma polymerization process using diethylene glycol dimethyl ether (Diglyme) as monomer. Molecular structure of the films was analyzed by Fourier Transform Infrared spectroscopy. The spectra exhibited absorption bands of O-H (3500-3200cm{sup -1}), C-H (3000-2900cm{sup -1}), C=O (1730-1650cm{sup -1}), C-O and C-O-C bonds at 1200-1600cm{sup -1}. The samples wettability was evaluated by measurements of contact angle using different liquids such as water, glycerol, poly-ethane and CMC. The polyurethane surface showed hydrophilic behavior after diglyme plasma-deposition with contact angle dropping from 85 deg. to 22 deg. Scanning Electron Microscopy revealed that diglyme films covered uniformly the polyurethane surfaces ensuring to it a biocompatible characteristic.

  4. Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Bezzi, Mario; Bruni, Antonio; Corona, Mario; Boatta, Emanuele; Lucatelli, Pierleone; Passariello, Roberto

    2011-01-01

    We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound–color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

  5. TOKYO criteria 2014 for transpapillary biliary stenting.

    Science.gov (United States)

    Isayama, Hiroyuki; Hamada, Tsuyoshi; Yasuda, Ichiro; Itoi, Takao; Ryozawa, Shomei; Nakai, Yousuke; Kogure, Hirofumi; Koike, Kazuhiko

    2015-01-01

    It is difficult to carry out meta-analyses or to compare the results of different studies of biliary stents because there is no uniform evaluation method. Therefore, a standardized reporting system is required. We propose a new standardized system for reporting on biliary stents, the 'TOKYO criteria 2014', based on a consensus among Japanese pancreatobiliary endoscopists. Instead of stent occlusion, we use recurrent biliary obstruction, which includes occlusion and migration. The time to recurrent biliary obstruction was estimated using Kaplan-Meier analysis with the log-rank test. We can evaluate both plastic and self-expandable metallic stents (uncovered and covered). We also propose specification of the cause of recurrent biliary obstruction, identification of complications other than recurrent biliary obstruction, indication of severity, measures of technical and clinical success, and a standard for clinical care. Most importantly, the TOKYO criteria 2014 allow comparison of biliary stent quality across studies. Because blocked stents can be drained not only using transpapillary techniques but also by an endoscopic ultrasonography-guided transmural procedure, we should devise an evaluation method that includes transmural stenting in the near future. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  6. The In Vivo Pericapsular Tissue Response to Modern Polyurethane Breast Implants.

    Science.gov (United States)

    Frame, James; Kamel, Dia; Olivan, Marcelo; Cintra, Henrique

    2015-10-01

    Polyurethane breast implants were first introduced by Ashley (Plast Reconstr Surg 45:421-424, 1970), with the intention of trying to reduce the high incidence of capsular contracture associated with smooth shelled, high gel bleed, silicone breast implants. The sterilization of the polyurethane foam in the early days was questionable. More recently, ethylene oxide (ETO)-sterilized polyurethane has been used in the manufacturing process and this has been shown to reduce the incidence of biofilm. The improved method of attachment of polyurethane onto the underlying high cohesive gel, barrier shell layered, silicone breast implants also encourages bio-integration. Polyurethane covered, cohesive gel, silicone implants have also been shown to reduce the incidence of other problems commonly associated with smooth or textured silicone implants, especially with reference to displacement, capsular contracture, seroma, reoperation, biofilm and implant rupture. Since the introduction of the conical polyurethane implant (Silimed, Brazil) into the United Kingdom in 2009 (Eurosurgical, UK), we have had the opportunity to review histology taken from the capsules of polyurethane implants in three women ranging from a few months to over 3 years after implantation. All implants had been inserted into virgin subfascial, extra-pectoral planes. The results add to the important previously described histological findings of Bassetto et al. (Aesthet Plast Surg 34:481-485, 2010). Five distinct layers are identified and reasons for the development of each layer are discussed. Breast capsule around polyurethane implants, in situ for fifteen and 20 years, has recently been obtained and analysed in Brazil, and the histology has been incorporated into this study. After 20 years, the polyurethane is almost undetectable and capsular contracture may appear. These findings contribute to our understanding of polyurethane implant safety, and give reasoning for a significant reduction in clinical

  7. Transjugular Intrahepatic Portosystemic Shunts in Patients with Cirrhosis with Refractory Ascites: Comparison of Clinical Outcomes by Using 8- and 10-mm PTFE-covered Stents.

    Science.gov (United States)

    Miraglia, Roberto; Maruzzelli, Luigi; Tuzzolino, Fabio; Petridis, Ioannis; D'Amico, Mario; Luca, Angelo

    2017-07-01

    Purpose To compare the efficacy and complications of transjugular intrahepatic portosystemic shunt (TIPS) creation performed by using a 10-mm or an 8-mm-diameter polytetrafluoroethylene (PTFE)-covered stent in a consecutive series of patients with cirrhosis with refractory ascites (RA). Materials and Methods The institutional review board approved this retrospective study and informed consent was waived. One hundred seventy-one patients with RA (mean age, 58.7 years ± 10.3; 95% confidence interval [CI]: 57.2 years, 60.3 years) had undergone TIPS placement by using 10-mm (60 patients) or 8-mm (111 patients) covered stent between January 2004 and December 2012. Median follow-up time was 16.8 months (range, 3.4-84.8 months). Hemodynamic changes, incidence of hepatic encephalopathy, and long-term (>3 months) need for paracentesis after TIPS placement were evaluated and calculated by using the Kaplan-Meier method and were compared by using the log-rank test. Results Pre-TIPS demographics and clinical characteristics of the two groups were comparable. The portosystemic gradient before TIPS was 17.0 mm Hg ± 4.2 (95% CI: 15.9 mm Hg, 18.1 mm Hg) in the 10-mm group versus 16.1 mm Hg ± 3.7 (95% CI: 15.4 mm Hg, 16.8 mm Hg) in the 8-mm group (P = .164). After TIPS, the portosystemic gradient was 6.5 mm Hg ± 3.4 (95% CI: 5.7 mm Hg, 7.4 mm Hg) in the 10-mm group versus 7.5 mm Hg ± 2.6 (95% CI: 6.9 mm Hg, 7.9 mm Hg) in the 8-mm group (P = .039). The long-term need for paracentesis was greater in the 8-mm group (64 of 111 patients [58%] vs 18 of 60 patients [31%], P = .003). Overall, hepatic encephalopathy was similar in both groups (45 of 111 patients [41%] vs 26 of 60 patients [44%], P = .728). Conclusion A10-mm PTFE-covered stent leads to better control of RA secondary to portal hypertension in patients with cirrhosis, compared with an 8-mm stent, without increasing the incidence of hepatic encephalopathy. © RSNA, 2017.

  8. An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, Garret T; Barton, Jennifer K [College of Optical Sciences, University of Arizona, Tucson, AZ (United States); Cardinal, Kristen O' Halloran [Biomedical and General Engineering, California Polytechnic State University (United States); Williams, Stuart K [Cardiovascular Innovation Institute, University of Louisville, Louisville, KY 40292 (United States)], E-mail: barton@u.arizona.edu

    2008-06-21

    Recent research has suggested that endothelialization of vascular stents is crucial to reducing the risk of late stent thrombosis. With a resolution of approximately 10 {mu}m, optical coherence tomography (OCT) may be an appropriate imaging modality for visualizing the vascular response to a stent and measuring the percentage of struts covered with an anti-thrombogenic cellular lining. We developed an image analysis program to locate covered and uncovered stent struts in OCT images of tissue-engineered blood vessels. The struts were found by exploiting the highly reflective and shadowing characteristics of the metallic stent material. Coverage was evaluated by comparing the luminal surface with the depth of the strut reflection. Strut coverage calculations were compared to manual assessment of OCT images and epi-fluorescence analysis of the stented grafts. Based on the manual assessment, the strut identification algorithm operated with a sensitivity of 93% and a specificity of 99%. The strut coverage algorithm was 81% sensitive and 96% specific. The present study indicates that the program can automatically determine percent cellular coverage from volumetric OCT datasets of blood vessel mimics. The program could potentially be extended to assessments of stent endothelialization in native stented arteries.

  9. Percutaneous biliary drainage and stenting

    International Nuclear Information System (INIS)

    Totev, M.

    2012-01-01

    stents for benign strictures. In cases of malignant obstruction, stents are placed as a palliative measure only if the tumor is unresectable. Various stents are approved for use in the biliary system, including self-expanding and balloon-mounted stents. Tumor ingrowth through the stent, proximal or distal tumor overgrowth, and biliary sludge can cause stent obstruction. Covered stents are now being investigated to overcome the problem of tumor ingrowth. The stent is usually placed at an interval of a few days after percutaneous biliary drainage (PBD), though in cases of uncomplicated percutaneous transhepatic cholangiography (PTC), the stent procedure can be accomplished at the same time. Through our institutional experience and literature overview, we will provide a review outlining the vast array of biliary stenting for both benign and malignant disease. We provided a thorough, concise, and informative review and show that the decompression of the biliary system by drainage or biliary stents is well tolerated by the patients procedure that provide an excellent and minimally invasive palliation, mainly in malignant obstructive jaundice.

  10. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  11. A Survival Analysis of Patients with Malignant Biliary Strictures Treated by Percutaneous Metallic Stenting

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Ptochis, Nikolaos; Panagiotou, Irene; Malagari, Katerina; Tzavara, Chara; Kelekis, Dimitrios

    2007-01-01

    Background. Percutaneous metal stenting is an accepted palliative treatment for malignant biliary obstruction. Nevertheless, factors predicting survival are not known. Methods. Seventy-six patients with inoperable malignant biliary obstruction were treated with percutaneous placement of metallic stents. Twenty patients had non-hilar lesions. Fifty-six patients had hilar lesions classified as Bismuth type I (n = 15 patients), type II (n = 26), type III (n = 12), or type IV (n = 3 patients). Technical and clinical success rates, complications, and long-term outcome were recorded. Clinical success rates, patency, and survival rates were compared in patients treated with complete (n = 41) versus partial (n = 35) liver parenchyma drainage. Survival was calculated and analyzed for potential predictors such as the tumor type, the extent of the disease, the level of obstruction, and the post-intervention bilirubin levels. Results. Stenting was technically successful in all patients (unilateral drainage in 70 patients, bilateral drainage in 6 patients) with an overall significant reduction of the post-intervention bilirubin levels (p < 0.001), resulting in a clinical success rate of 97.3%. Clinical success rates were similar in patients treated with whole-liver drainage versus partial liver drainage. Minor and major complications occurred in 8% and 15% of patients, respectively. Mean overall primary stent patency was 120 days, while the restenosis rate was 12%. Mean overall secondary stent patency was 242.2 days. Patency rates were similar in patients with complete versus partial liver drainage. Mean overall survival was 142.3 days. Survival was similar in the complete and partial drainage groups. The post-intervention serum bilirubin level was an independent predictor of survival (p < 0.001). A cut-off point in post-stenting bilirubin levels of 4 mg/dl dichotomized patients with good versus poor prognosis. Patient age and Bismuth IV lesions were also independent predictors

  12. Drug eluting stents and modern stent technologies for in-stent restenosis.

    Science.gov (United States)

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  13. Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Guntau, Moritz, E-mail: guntau@med.uni-marburg.de [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hegele, Axel [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Rheinheimer, Stephan [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hofmann, Rainer [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Mahnken, Andreas H. [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany)

    2017-06-15

    PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications. Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.

  14. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  15. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    Science.gov (United States)

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. The cover stent custody case that acknowledged QOL improvement on traffic between trachea and esophagus of esophagus cancer

    International Nuclear Information System (INIS)

    Nagase, Hirotsugu; Okada, Kazuyuki; Murata, Kohei

    2011-01-01

    The case was a 60-year-old man. The patient with a main complaint of husky voice was introduced by a nearby doctor to our otolaryngology department at the end of August 2009. Because of the wall thickening image of the upper part (Ut domain) esophagus, left infraclavicular lymph node and mediastium lymphadenopathy syndrome observed by head and neck CT, the patient was transferred to surgery department. Squamous cell carcinoma was diagnosed based on the upper part gastrointestinal tract endoscopy showing a type-3 advanced cancer of the upper thoracic esophagus sized 25-30 cm from nostril. The patient was in progressive disease (PD), fever and coughing, though we performed 2 FAP therapies. A chest CT revealed that there was a passage between the trachea and esophagus. Then, radiation therapy (a total of 60 Gy, 2 Gy at a time) was enforced. After the radio therapy, a covered type Ultraflex esophagus stent was inserted due to a fistula, though the tumor was reduced to 6 mm in size. The patient was passed away five months after the stent custody; a solid food intake was possible until just before he died. (author)

  17. Feasibility of Angioplasty and Stenting for Abdominal Aortic Lesions Adjacent to Previously Stented Visceral Artery Lesions in Patients with Takayasu Arteritis

    International Nuclear Information System (INIS)

    Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas

    2007-01-01

    Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis

  18. Successful Treatment of Bronchoesophageal Fistula With Esophageal and Bronchial Stenting

    Directory of Open Access Journals (Sweden)

    Cheng-Yi Wang

    2011-04-01

    Full Text Available Bronchoesophageal fistula is reported in 5-10% of patients with esophageal cancer. In most of these cases, the insertion of a single stent, either a tracheobronchial or an esophageal stent, is sufficient to seal off the fistula. In this case we describe a 67-year-old man with esophageal cancer and complications of bronchoesophageal fistula, which resulted in repeated pneumonia and acute respiratory failure. Initially, two expandable metallic membranous esophageal stents were placed to cover the fistula. However, the esophageal stent failed to stop the air leak and dislodged into the stomach. Thereafter, a bronchial stent was placed at the right intermediate bronchus and successfully stopped the air leak. The patient was then weaned from the ventilator 1 week after the insertion of a bronchial stent. In conclusion, stenting in both the esophagus and airways should be considered when both are severely invaded by malignancy, when the airway is compressed, or when the fistula is insufficiently sealed by an esophageal stent.

  19. Long-Term Outcomes of Double-Layered Polytetrafluoroethylene Membrane-Covered Self-Expandable Segmental Metallic Stents (Uventa) in Patients with Chronic Ureteral Obstructions: Is It Really Safe?

    Science.gov (United States)

    Kim, Myong; Hong, Bumsik; Park, Hyung Keun

    2016-12-01

    To evaluate the long-term clinical efficacy and safety of double-layered polytetrafluoroethylene membrane-covered self-expandable segmental metallic stents (Uventa) in patients with chronic ureteral obstruction. In a retrospective study, a total of 50 ureter units (44 patients) with chronic obstructions were included from July 2010 to May 2015. Indications for Uventa placement were primary stenting for malignant ureteral obstruction, failed conventional polymeric Double-J stent (PS), or percutaneous nephrostomy (PCN) technique, with comorbidities or fears limiting PS/PCN changes, or with irritation or pain due to PS/PCN. Patients underwent Uventa stent placement using the antegrade or retrograde approach. There were no immediate procedure-related complications, and all stents were placed in the proper sites. During the median follow-up of 30.9 (interquartile range [IQR], 8.1-49.0) months, the primary (no obstruction and no additional intervention) and overall success (no obstruction and no additional intervention except supplementary Uventa) was 30.0% and 34.0%, respectively. Moreover, 14 of 50 ureter units (28.0%) experienced major complications (≥Clavien-Dindo class IIIb), such as ureteroarterial fistula (three cases, 6.0%), ureteroenteric fistula (three, 6.0%), ureterovaginal fistula (one, 2.0%), ureter perforation (one, 2.0%), uncontrollable bleeding (one, 2.0%), and complete obstruction (five, 10.0%). On univariate analysis, major complications were associated with female (odds ratio [OR] = 6.000), cervical cancer (OR = 4.667), ureteral stricture length (≥6.0 cm, OR = 4.583), and placement duration (≥24.0 months, OR = 20.429; all p stent demonstrated poor treatment outcomes with frequent major complications in patients with chronic ureteral obstructions.

  20. Radioactive metallic stent for palliative treatment of esopageal cancer using Ho-166: an experimental study in canine model

    Energy Technology Data Exchange (ETDEWEB)

    Won, J. H.; Lee, J. D. [College of Medicine, Yonsei Univ., Seoul (Korea, Republic of); Wang, H. J.; Lim, H. E.; Park, C. H. [College of Medicine, Ajou Univ., Inchon (Korea, Republic of); Park, K. B. [KAERI, Taejon (Korea, Republic of)

    1999-07-01

    Self-expandable metallic stents are widely used for palliative treatment of esophageal cancer, however, tumor overgrowth and short survaval limit its long-term effect. The purpose of this study is to evaluate tissue response of the radiation effect in normal canine esophagus whether metallic stents coated with radioactive H-166 is effective for patients survival and preservation of stent patency longer than stents without radioactive materials. Ho-166 was incorporated within polyurethan (50{mu}) and coated over the outer surface of self-expandable metallic stents. Metallic stents with radioactivity of 4.0-7.8mCi (Group A), 1.0-1.8 mCi (Group B) and 0.5-0.7mCi (Group C) were placed in normal mid-esophagus in twelve dogs (Group A), five (Group B) and another five dogs (Group C) respectively, and the stents were tightly anchored by surgery to prevent migration. Estimated radiation dose was 6-70 Gy in Group C. Fluoroscopy confirmed stents in esophagus without migration for at least two days. The dogs were sacrified at two or three months later and histopathologic examinations were performed. In group A, mid-esophagus stricture, mucosal ulceration were found in all specimens. Severe fibrosis and degeneration of muscular propria, upper one half were found in three and complete fibrosis of esophageal wall, however, esophageal perforation was found but muscular layer was intact. In group C, no histological changes was demonstrated in three but submucosal inflammation with intact mucosa in two. In therapeutic dose level (group B), radioactive metallic stent showed radiation effect within esophageal wall without complication which might give additional palliative effect in malignant espohageal stricture.

  1. A prospective group sequential study evaluating a new type of fully covered self-expandable metal stent for the treatment of benign biliary strictures (with video).

    Science.gov (United States)

    Poley, Jan-Werner; Cahen, Djuna L; Metselaar, Herold J; van Buuren, Henk R; Kazemier, Geert; van Eijck, Casper H J; Haringsma, Jelle; Kuipers, Ernst J; Bruno, Marco J

    2012-04-01

    Fully-covered self expandable metal stents (fcSEMSs) are an alternative to progressive plastic stenting for the treatment of benign biliary strictures (BBS) with the prospect of a higher treatment efficacy and the need for fewer ERCPs, thereby reducing the burden for patients and possibly costs. Key to this novel treatment is safe stent removal. To investigate the feasibility and safety of stent removal of a fcSEMS with a proximal retrieval lasso: a long wire thread integrated in the proximal ends of the wire mesh that hangs freely in the stent lumen. Pulling it enables gradual removal of the stent inside-out. A secondary aim was success of stricture resolution. Non-randomized, prospective follow-up study with 3 sequential cohorts of 8 patients with BBS. Academic tertiary referral center. Eligible patients had strictures either postsurgical (post-cholecystectomy (LCx) or liver transplantation (OLT)), due to chronic pancreatitis (CP), or papillary stenosis (PF). Strictures had to be located at least 2 cm below the liver hilum. All patients had one plastic stent in situ across the stricture and had not undergone previous treatment with either multiple plastic stents or fcSEMS. The first cohort of patients underwent stent placement for 2 months, followed by 3 months if the stricture had not resolved. The second and third cohort started with 3 months and 4 months, respectively, both followed by another 4 months if indicated. Treatment success was defined by stricture resolution at cholangiography, the ability to pass an inflated extraction balloon and clinical follow-up (at least 6 months). safety of stent removal. Secondary outcomes were complications and successful stricture resolution. A total of 23 patients (11 female; 20-67 yrs) were eligible for final analysis. One patient developed a malignant neuroendocrine tumor in the setting of CP. Strictures were caused by CP (13), OLT (6), LCx (3) and PF (1). In total 39 fcSEMS were placed and removed. Removals were easy

  2. Removal of self expandable metallic airway stent: A rare case report

    Directory of Open Access Journals (Sweden)

    Rakesh K Chawla

    2013-01-01

    Full Text Available Covered self expandable metallic airway stents (SEMS have been used for benign tracheal stenosis, post intubation tracheal stenosis, tracheal burn or trauma, tracheo-broncho-malacia, and extrinsic compression of trachea. Their placement is considered to be permanent, with open surgery the only way to remove the stent, though there are few cases reports of their removal with the bronchoscope, but the complications after their removal are very high. In our patient, one and a half years after placement of SEMS, she developed cough with dyspnoea, video bronchoscopy showed stenosis above the level of stent with granulation tissue inside the stent, stent fracture in lower part and stent migration to right main bronchus, thus she had all conceivable complications of stent placement. The stent was removed with the help of rigid bronchoscope under general anaesthesia. She was discharged the following day. The case is being reported because it was unique in having all the possible complications of stent placement, and rare as we could take out the stent in Toto. Thirdly, the stent could be removed without any complication.

  3. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    Science.gov (United States)

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p stent use for palliation (78.6% vs 56.3%; p stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes of self-expandable metal stent placement and must be considered by endoscopists. See Video Abstract at http

  4. Efficacy of SMART Stent Placement for Salvage Angioplasty in Hemodialysis Patients with Recurrent Vascular Access Stenosis

    Directory of Open Access Journals (Sweden)

    Shingo Hatakeyama

    2011-01-01

    Full Text Available Vascular access stenosis is a major complication in hemodialysis patients. We prospectively observed 50 patients in whom 50 nitinol shape-memory alloy-recoverable technology (SMART stents were used as salvage therapy for recurrent peripheral venous stenosis. Twenty-five stents each were deployed in native arteriovenous fistula (AVF and synthetic arteriovenous polyurethane graft (AVG cases. Vascular access patency rates were calculated by Kaplan-Meier analysis. The primary patency rates in AVF versus AVG at 3, 6, and 12 months were 80.3% versus 75.6%, 64.9% versus 28.3%, and 32.3% versus 18.9%, respectively. The secondary patency rates in AVF versus AVG at 3, 6, and 12 months were 88.5% versus 75.5%, 82.6% versus 61.8%, and 74.4% versus 61.8%, respectively. Although there were no statistically significant difference in patency between AVF and AVG, AVG showed poor tendency in primary and secondary patency. The usefulness of SMART stents was limited in a short period of time in hemodialysis patients with recurrent vascular access stenosis.

  5. Stent-over-sponge (SOS): a novel technique complementing endosponge therapy for foregut leaks and perforations.

    Science.gov (United States)

    Valli, Piero V; Mertens, Joachim C; Kröger, Arne; Gubler, Christoph; Gutschow, Christian; Schneider, Paul M; Bauerfeind, Peter

    2018-02-01

     Endoluminal vacuum therapy (EVT) has evolved as a promising option for endoscopic treatment of foregut wall injuries in addition to the classic closure techniques using clips or stents. To improve vacuum force and maintain esophageal passage, we combined endosponge treatment with a partially covered self-expandable metal stent (stent-over-sponge; SOS).  Twelve patients with infected upper gastrointestinal wall defects were treated with the SOS technique.  Indications for SOS were anastomotic leakage after surgery (n = 11) and chronic foregut fistula (n = 1). SOS treatment was used as a first-line treatment in seven patients with a success rate of 71.4 % (5/7) and as a second-line treatment after failed previous EVT treatment in five patients (success rate 80 %; 4/5). Overall, SOS treatment was successful in 75 % of patients (9/12). No severe adverse events occurred. CONCLUSION : SOS is an effective method to treat severely infected foregut wall defects in patients where EVT has failed, and also as a first-line treatment. Comparative prospective studies are needed to confirm our preliminary results. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Mesh-covered (Roadsaver stent as a new treatment modality for symptomatic or high-risk carotid stenosis

    Directory of Open Access Journals (Sweden)

    Roman Machnik

    2017-05-01

    Full Text Available Introduction : Prevention of periprocedural stroke has a crucial role in carotid artery stenting (CAS procedures. Aim : To assess retrospectively 30-day safety and effectiveness of 41 procedures of internal and common carotid artery stenting using the Roadsaver double nitinol layer micromesh stent in 40 non-consecutive patients with symptomatic or high-risk carotid artery stenosis. Material and methods : The patients were men (n = 31 and women (n = 9; mean age was 67.8 ±7.9 years. Femoral access was used in 39 cases, whereas radial access was used in 2. Proximal (n = 27 or distal (n = 14 embolic neuroprotection was used. Results : The Roadsaver stents (nominal diameter 7, 8 or 9 mm, length 25 or 30 mm were implanted successfully in all cases. One minor stroke occurred after common carotid artery intubation with a guiding catheter (before stent deployment and one transient postprocedural ischemic attack (TIA of the ipsilateral cerebral hemisphere was observed. Internal/common carotid artery stenosis severity was evaluated by duplex Doppler. Maximal peak systolic velocity (PSV before CAS was in the range: 2.0–7.0 m/s, mean: 3.9 ±1.0 m/s, at 24–48 h after stenting mean PSV was 1.1 ±0.4 m/s (p < 0.05, and at 30 days 1.1 ±0.3 m/s (p < 0.05. Maximal end-diastolic velocity (EDV was 0.85–3.5 m/s, mean 1.4 ±0.5 m/s, at 24–48 h after stenting mean EDV was 0.3 ±0.1 m/s (p < 0.05, and at 30 days 0.4 ±0.1 m/s (p < 0.05. No restenosis or thrombosis was observed. Angiographic stenosis decreased from 82.9 ±9.1% (range: 61–97% to 19.3 ±7.3% (range: 0–34% (p < 0.05. Conclusions : The CAS using the Roadsaver stent seems to be safe and effective. Further studies involving larger patient populations and longer follow-up are needed.

  7. Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation

    International Nuclear Information System (INIS)

    Maintz, David; Juergens, Kai-Uwe; Heindel, Walter; Fischbach, Roman; Wichter, Thomas; Grude, Matthias

    2003-01-01

    The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type. (orig.)

  8. Polyurethane compounds having carbon nanotubes

    NARCIS (Netherlands)

    2010-01-01

    The invention relates to semi-crystalline polyurethane (PUR) compositions filled with carbon nanotubes (CNT) and having improved electrical properties, which can be obtained on the basis of water-based polyurethane/CNT mixtures. The invention further relates to a method for producing polyurethane

  9. Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2014-01-01

    Full Text Available Tracheal penetration of esophageal self-expanding metallic stents (SEMS with/without tracheoesophageal fistula (TEF formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breathing difficulty and aspiration following third esophageal stent placement, tracheal erosion and TEF formation due to the tracheal penetration by esophageal stent were diagnosed. The patient was successfully managed by covered tracheal SEMS placement under flexible bronchoscopy.

  10. Partial pleural covering for intractable pneumothorax in patients with Birt-Hogg-Dubé Syndrome.

    Science.gov (United States)

    Okada, Akira; Hirono, Tatsuhiko; Watanabe, Takehiro; Hasegawa, Go; Tanaka, Reiko; Furuya, Mitsuko

    2017-03-01

    Birt-Hogg-Dubé syndrome (BHD) is an inherited disorder associated with a germline mutation of the folliculin (FLCN) gene. Most patients with BHD have multiple pulmonary cysts, and are at high risk of repeated pneumothorax. Although an increasing number of patients are diagnosed with BHD by genetic testing, therapeutic approaches for intractable pneumothorax have not yet been described. We treated three patients who had repeated episodes of pneumothorax. All had multiple pulmonary cysts in the lower lobes, and two had a family history of pneumothorax. Video-assisted thoracic surgery was used to perform wedge resections and partial pleural covering of the cystic lesions. The partial pleural covering technique used sheets of polyglycolic acid felt or regenerative oxidized cellulose mesh. The resected tissues underwent histopathological evaluation, and peripheral blood leukocytes were tested for FLCN mutations. The operative times were less than 2 h, and there were no complications. The resected cysts had histopathological features characteristic of BHD lung. All patients were found to have FLCN germline mutations; thus their repeated pneumothoraces were a manifestation of BHD. None of the patients developed respiratory problems after undergoing the partial pleural covering procedure, and they have all been well without pneumothorax for 30 months or more. Partial pleural covering combined with resection of protruding cysts should be a safe and effective therapeutic approach for BHD patients with intractable pneumothorax. Further investigation is needed to establish a detailed protocol for treatment of pneumothorax that results in minimal functional impairment. © 2015 John Wiley & Sons Ltd.

  11. Clinical observation of covered for malignant esophageal stricture and esophagus-bronchial fistula

    International Nuclear Information System (INIS)

    Luo Hailong; Lin Youen; Ye Zhi; Zhu Yifen

    2010-01-01

    Objective: To evaluate clinical value of self-expanded covered stents for advanced stage esophageal cancer complicated by esophageal stricture and esophagus-bronchial fistula. Methods: Self-expanded covered stents were placed into 48 patients with advanced stage esophageal cancer under fluoroscopy. Of the 48 patients, 39 had malignant esophageal stricture and 9 had esophagus-bronchus fistula. Results: Stents were successfully inserted into all but one patient with lower esophageal cancer and gastric volvulus. Deglutition was improved in all patients and coughing resolved in patients with esophagus-bronchus fistula. Thoracodynia and foreign body sensation vanished within one week after operation in all patients. Dyspnea caused by compression of the left main bronchus occurred in one patient. Re-stenosis of the stents occurred three to seven months after operation in eight patients. The mean survival time was seven months in all patients. Conclusion: Self-expanded covered stent placement is a simple, safe and reliable treatment method for advanced stage esophageal cancer and can effectively lengthen survival time. (authors)

  12. Expandable esophageal metallic stents coating with silicone rubber: An experimental study in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Han, Young Min; Son, Myung Hee; Kim, Jong Soo; Choi, Ki Chul; Kuh, Ja Hong; Chae, Soo Wan [Chonbuk National University Medical School, Chonju (Korea, Republic of); Kim, Hak Nam [Chungju Lee Rha Hospital, Chungju (Korea, Republic of)

    1990-10-15

    To determine the effect of the expandable esophageal metallic stents on the esophagus, we constructed an expandable metallic stent. It was stainless steel wire formed in a zig-zag pattern in fully expanded diameter. Twenty stents were introduced in the normal esophagus through a 8.5 French-teflon sheath in 10 rabbits for 1 week to 12 weeks. Three out of the 20 stents migrated slightly. At 1 week after the placement of the stent, the mucosa partly revealed pressure necrosis and some regeneration, the muscle layer below the stent wires found compressed and thinned. At 8 weeks, the mucosa showed complete regeneration, and the stent wires were found covered by fibrous tissue.

  13. Serial Versus Direct Dilation of Small Diameter Stents Results in a More Predictable and Complete Intentional Transcatheter Stent Fracture: A PICES Bench Testing Study.

    Science.gov (United States)

    Crystal, Matthew A; Morgan, Gareth J; Danon, Saar; Gray, Robert G; Gruenstein, Daniel H; Gordon, Brent M; Goldstein, Bryan H

    2018-01-01

    Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to

  14. Spectral Imaging for Intracranial Stents and Stent Lumen.

    Science.gov (United States)

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P stent lumen (160.03 ±37.79; P stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  15. Novel deployment of a covered duodenal stent in open surgery to facilitate closure of a malignant duodenal perforation

    Directory of Open Access Journals (Sweden)

    Psaila Josephine

    2009-10-01

    Full Text Available Abstract Background Its a dilemma to attempt a palliative procedure to debulk the tumour and/or prevent future obstructive complications in a locally advanced intra abdominal malignancy. Case presentation A 38 year old Vietnamese man presented with a carcinoma of the colon which had invaded the gallbladder and duodenum with a sealed perforation of the second part of the duodenum. Following surgical exploration, it was evident that primary closure of the perforated duodenum was not possible due to the presence of unresectable residual tumour. Conclusion We describe a novel technique using a covered duodenal stent deployed at open surgery to aid closure of a malignant duodenal perforation.

  16. Efficacy of a dexamethasone-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt: an experimental study in a swine model

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Korea University Guro Hospital, Seoul (Korea, Republic of); Oh, Joo Hyeogn; Park, Young Koo [Kyung Hee University Hospital, Seoul (Korea, Republic of); Song, Ho Young [University of Ulsan, College of Medicine, Seoul (Korea, Republic of); Park, Sang Joon [Hallym University, College of Medicine, Seoul (Korea, Republic of); Yuk, Sun Hong [Hannam University, Daejeon (Korea, Republic of)

    2005-12-15

    We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudointima was evaluated both on follow-up portogram and pathologic examination. One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudointimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. The DM-eluting stent showed a tendency to reduce the development of pseudointimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension.

  17. 21 CFR 177.1680 - Polyurethane resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyurethane resins. 177.1680 Section 177.1680 Food... of Single and Repeated Use Food Contact Surfaces § 177.1680 Polyurethane resins. The polyurethane...) For the purpose of this section, polyurethane resins are those produced when one or more of the...

  18. Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

    International Nuclear Information System (INIS)

    Riga, Celia V.; Bicknell, Colin D.; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-01-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  19. Tracheal stenosis after treatment with metallic stent: a situation worse than the initial problem

    International Nuclear Information System (INIS)

    Barreto, Jaime; Mejia, Bibiana; Nino, Federico; Garavito, Carlos

    2008-01-01

    Stens are a tubular device for use in trachea, carina or main bronchus to provide a support and maintain the permeability of these structures. There are two groups: Metallic and Silicone stent. Either metallic and silicone stents has a special properties. Metallic stent are very attractive option due to relative easy in their placement. The accumulated experience in this therapy has allowed to recognize several complications to take into consideration mainly in patients with tracheal benign stenosis. FDA has recommended don't use metallic stents, covered and not covered in benign diseases. We report a case of a tracheal stenosis secondary to prolonged ortho tracheal intubation that required extensive interventions to control symptoms of central airway obstruction, between April and July of 2005.

  20. Randomized clinical comparison of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent with the sirolimus-eluting Orsiro stent in patients treated with percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jakobsen, Lars; Christiansen, Evald H; Maeng, Michael

    2018-01-01

    Background: The Combo stent (OrbusNeich, Hoevelaken, the Netherlands) combining an abluminal, bioabsorbable polymer eluting sirolimus with a luminal CD34+ antibody to capture endothelial progenitor cells has been developed to further improve safety and efficacy of coronary interventions. We have...... designed a large-scale registry-based randomized clinical trial to compare the Combo stent to the Orsiro stent (Biotronik, Bülach, Switzerland) in patients undergoing percutaneous coronary intervention. Methods: The SORT OUT X study will randomly assign 3,140 patients to treatment with Combo or Orsiro...... stents at 3 sites in Western Denmark. Patients are eligible if they are ≥18 years old, have chronic stable coronary artery disease or acute coronary syndromes, and have ≥1 coronary lesion with >50% diameter stenosis requiring treatment with a drug-eluting stent. The primary end point target lesion...

  1. Biliary Leak in Post-Liver-Transplant Patients: Is There Any Place for Metal Stent?

    Directory of Open Access Journals (Sweden)

    Fernanda P. Martins

    2012-01-01

    Full Text Available Objectives. Endoscopic management of bile leak after orthotopic liver transplant (OLT is widely accepted. Preliminary studies demonstrated encouraging results for covered self-expandable metal stents (CSEMS in complex bile leaks. Methods. Thirty-one patients with post-OLT bile leaks underwent endoscopic temporary placement of CSEMS (3 partially CSEMS , 18 fully CSEMS with fins and 10 fully CSEMS with flare ends between December 2003 and December 2010. Long-term clinical success and safety were evaluated. Results. Median stent indwelling and follow-up were 89 and 1,353 days for PCSEMS, 102 and 849 for FCSEMS with fins and 98 and 203 for FCSEMS with flare ends. Clinical success was achieved in 100%, 77.8%, and 70%, respectively. Postplacement complications: cholangitis (1 and proximal migration (1, both in the FCSEMS with fins. Postremoval complications were biliary strictures requiring drainage: PCSEMS (1, FCSEMS with fins (6 and with flare ends (1. There was no significant differences in the FCSEMS groups regarding clinical success, age, gender, leak location, previous treatment, stent indwelling, and complications. Conclusion. Temporary placement of CSEMS is effective to treat post-OLT biliary leaks. However, a high number of post removal biliary strictures occurred especially in the FCSEMS with fins. CSEMS cannot be recommended in this patient population.

  2. Predictors of early stent occlusion among plastic biliary stents.

    Science.gov (United States)

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  3. Covered Bronchial Stent Insertion to Manage Airway Obstruction with Hemoptysis Caused by Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sae Ah; Kim, Do Hyeong [Dankook University College of Medicine, Dankook University Hospital, Cheonan (Korea, Republic of); Jen, Gyeong Sik [Bundang CHA General Hospital, CHA University, Seongnam (Korea, Republic of)

    2012-07-15

    Malignant airway obstruction and hemoptysis are common in lung cancer patients. Recently, airway stent is commonly used to preserve airway in malignant airway obstruction. Hemoptysis can be managed through various methods including conservative treatment, endobronchial tamponade, bronchoscopic intervention, embolization and surgery. In our case studies, we sought to investigate the effectiveness of airway stents for re-opening the airway as well as tamponade effects in four patients with malignant airway obstruction and bleeding caused by tumors or lymph node invasions.

  4. Biodegradable stents for the treatment of refractory or recurrent benign esophageal stenosis.

    Science.gov (United States)

    Imaz-Iglesia, Iñaki; García-Pérez, Sonia; Nachtnebel, Anna; Martín-Águeda, Belén; Sánchez-Piedra, Carlos; Karadayi, Bilgehan; Demirbaş, Ali Rıza

    2016-06-01

    Esophageal stents are used for the treatment of refractory and recurrent dyphagias. In 2007, esophageal biodegradable stents (EBS) were authorised as an alternative to existing metal and plastic stents in Europe. The advantages claimed for EBS are fewer complications concerning tissue ingrowth, stent migration and stent removal. We performed a systematic review to evaluate the efficacy and safety of EBS compared to fully-covered self-expanding metal stents, self-expanding plastic stents, and esophageal dilation for the treatment of refractory or recurrent benign esophageal stenosis. Three comparative studies (one randomized controlled trial and two cohort studies) were assessed. The studies used different inclusion criteria, had a very small (sample) size and the quality of the evidence was very low. Expert commentary: The current evidence is insufficient to determine the relative efficacy or safety of esophageal biodegradable stents. The results of this systematic review should be updated once new evidence is available.

  5. Medium-term follow-up after deployment of ultraflex expandable metallic stents to manage endobronchial pathology.

    Science.gov (United States)

    Madden, Brendan P; Park, John E S; Sheth, Abhijat

    2004-12-01

    Between March 1997 and March 2004 we deployed 80 Ultraflex metallic expandable stents (Boston Scientific, Waterson, MA) in 69 patients under direct vision using rigid bronchoscopy. We report our medium- to long-term experience in patients for whom these stents were deployed. To date 15 patients have been followed for more than 1 year (median 41 months, range 12 to 83 months) after stent deployment. Indications for stenting in these patients were neoplasia (5), stricture (5), airway malacia (1), iatrogenic tracheal tear (1), and compression from an aortic aneurysm (1), a right interrupted aortic arch (1), and a right brachiocephalic artery aneurysm with tracheomalacia (1). Ten tracheal stents (9 covered, 1 uncovered) and 10 bronchial stents (8 uncovered, 2 covered) were inserted, and 5 patients received two stents. Five of these patients experienced no long-term problems. Complications included troublesome halitosis (5), which was difficult to treat despite various antibiotic regimes; granulation tissue formation above and below the stent that was successfully treated with low-power Nd:YAG laser therapy (7); and metal fatigue (1). We did not encounter stent migration. We conclude that Ultraflex expandable metallic stents have an important role in the management of selected patients with diverse endobronchial pathologies and are well tolerated in the long-term. Although associated granulation tissue can be successfully treated with Nd:YAG laser, halitosis can be a difficult problem to address.

  6. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation

    DEFF Research Database (Denmark)

    Thayssen, Per; Jensen, Lisette Okkels; Lassen, Jens Flensted

    2012-01-01

    Aims: Data are limited on the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with coronary stents. We examined the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with percutaneous coronary intervention (PCI). Methods and results......: All patients who underwent stent implantation from 2002 to 2005 were identified in the Western Denmark Heart Registry. The hazard ratio (HR) for death associated with stent thrombosis or in-stent restenosis was estimated with a Cox regression analysis with stent thrombosis or in-stent restenosis...... as time-dependent variables. A total of 12,277 patients were treated with stent implantation. Stent thrombosis was observed in 111 (0.9%) patients and in-stent restenosis in 503 (4.1%) patients within 12 months after the index PCI. Occurrence of stent thrombosis was associated with an increased risk...

  8. Percutaneous unilateral biliary metallic stent placement in patients with malignant obstruction of the biliary hila and contralateral portal vein steno-occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Son, Rak Chae; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jong Woo; Ko, Gi Young [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    To investigate the outcomes of percutaneous unilateral metallic stent placement in patients with a malignant obstruction of the biliary hila and a contralateral portal vein steno-occlusion. Sixty patients with a malignant hilar obstruction and unilobar portal vein steno-occlusion caused by tumor invasion or preoperative portal vein embolization were enrolled in this retrospective study from October 2010 to October 2013. All patients were treated with percutaneous placement of a biliary metallic stent, including expanded polytetrafluoroethylene (ePTFE)-covered stents in 27 patients and uncovered stents in 33 patients. A total of 70 stents were successfully placed in 60 patients. Procedural-related minor complications, including self-limiting hemobilia (n = 2) and cholangitis (n = 4) occurred in six (10%) patients. Acute cholecystitis occurred in two patients. Successful internal drainage was achieved in 54 (90%) of the 60 patients. According to a Kaplan-Meier analysis, median survival time was 210 days (95% confidence interval [CI], 135-284 days), and median stent patency time was 133 days (95% CI, 94-171 days). No significant difference in stent patency was observed between covered and uncovered stents (p = 0.646). Stent dysfunction occurred in 16 (29.6%) of 54 patients after a mean of 159 days (range, 65-321 days). Unilateral placement of ePTFE-covered and uncovered stents in the hepatic lobe with a patent portal vein is a safe and effective method for palliative treatment of patients with a contralateral portal vein steno-occlusion caused by an advanced hilar malignancy or portal vein embolization. No significant difference in stent patency was detected between covered and uncovered metallic stents.

  9. Biological effect of microengineered grooved stents on strut healing: a randomised OCT-based comparative study in humans

    Science.gov (United States)

    Vesga, Boris; Hernandez, Hector; Higuera, Sergio; Gasior, Pawel; Echeveri, Dario; Delgado, Juan A; Dager, Antonio; Arana, Camilo; Simonton, Charles; Maehara, Akiko; Palmaz, Julio; Granada, Juan F

    2017-01-01

    Objective To evaluate the biological effect of microengineered stent grooves (MSG) on early strut healing in humans by performing optical coherence tomography (OCT) analysis 3 weeks following the implantation. Background In the experimental setting, MSG accelerate endothelial cell migration and reduce neointimal proliferation compared with bare metal stent (BMS). Methods A total of 37 patients undergoing percutaneous coronary intervention with de novo coronary lesions were randomly assigned to either MSG (n=19) or an identical BMS controls (n=18). All patients underwent OCT imaging at 3 weeks. A total of 7959 struts were included in the final analysis. Results At 3 weeks following stent implantation, almost all struts analysed (~97%) had evidence of tissue coverage. The percentage of partially covered struts was comparable between both groups. However, the percentage of fully embedded struts was higher in the BMS group (81.22%, 49.75–95.52) compared with the MSG group (74.21%, 58.85–86.38). The stent-level analysis demonstrated reduction in neointimal formation (neointimal hyperplasia area and volume reduction of ~14% and ~19%, respectively) in the MSG versus the BMS group. In the strut-level analysis, an even greater reduction (~22% in neointimal thickness) was seen in the MSG group. Layered neointimal was present in ~6% of the OCT frames in the BMS group while it was not present in the MSG group. Conclusions MSG induced a more homogeneous and predictable pattern of surface healing in the early stages following stent implantation. The biological effect of MSG on stent healing has the potential to improve the safety profile of current generation drug-eluting stents. Classifications BMS, OCT, clinical trials. PMID:28674616

  10. A new fully covered metal stent with anti-migration features for the treatment of malignant dysphagia

    NARCIS (Netherlands)

    Walter, Daisy; van den Berg, Maarten W.; van Hooft, Jeanin E.; Boot, Henk; Scheffer, Robert C. H.; Vleggaar, Frank P.; Siersema, Peter D.

    2014-01-01

    A new esophageal stent with two anti-migration features was developed to minimize migration. The aim of this study was to evaluate the clinical efficacy and safety of this stent in patients with malignant dysphagia. A total of 40 patients with dysphagia due to a malignant obstruction of the

  11. Polyurethane membranes for surgical gown applications

    Science.gov (United States)

    Ukpabi, Pauline Ozoemena

    The Occupational Safety and Health Administration (OSHA) recently issued a directive requiring all employers to supply personnel protective equipment to employees who are at risk of exposure to blood or other potentially infectious body fluids. For the healthcare worker, a wide variety of surgical gowns is available commercially but there are concerns over their barrier effectiveness and/or wearer comfort. To successfully create a barrier fabric which combines resistance to fluid penetration with comfort, a complete understanding of the relationship between membrane structure and functional properties is required. In this study, we investigated the surface properties of hydrophilicity and hydrophobicity in polyurethane membranes intended for use in surgical gowns. The polyurethane membranes were grafted with side chains of varying lengths, polyethylene glycol (PEG) being used for the hydrophilic modifications and perfluoroalkyl compounds (a monofunctional acid and a difunctional amino alcohol) for the hydrophobic modifications. The hydrophilic treatment was intended to improve the comfort properties of monolithic membranes without adversely affecting their barrier properties. The hydrophobic treatment, on the other hand, was intended to improve the fluid repellency and hence barrier properties of microporous membranes without adversely affecting their comfort properties. Reflection infrared spectroscopy showed that fluorine was successfully grafted onto the polyurethane backbone during the hydrophobic modification, but was not sensitive enough to detect PEG grafting in leached polyethylene glycol-treated polyurethanes. X-ray photoelectron spectroscopy showed that the perfluoroalkylated polyurethanes contained up to 40% fluorine on their surfaces and the PEG-treated polyurethanes showed an increase in their C-O content over the unmodified polyurethane. Scanning electron microscopy not only showed that perfluoroalkylation yielded polyurethane membranes with very

  12. Efeitos a curto prazo de "stents" não recobertos e recobertos com politetrafluoroetileno em aorta de suínos: um modelo experimental Short-term effects of polytetrafluoroethylene covered and uncovered metallic "stents" in pig aorta: an experimental model

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Grüdtner

    2004-04-01

    Full Text Available OBJETIVO: Descrever um estudo experimental avaliando através da morfometria digital o espessamento intimal na parede arterial após o implante de "stents" metálicos auto-expansíveis recobertos ou não com politetrafluoroetileno (PTFE na aorta de suínos. MÉTODOS: Em três grupos de suínos jovens uma bainha introdutora de 12 F foi inserida na aorta abdominal distal. Os animais do grupo I (n=5 foram considerados controle. Os animais do grupo II (n=10 receberam o implante de um stent metálico auto-expansível não recoberto. No grupo III (n=10 um stent auto-expansível recoberto com PTFE foi inserido. Após quatro semanas os animais foram sacrificados e os espécimes arteriais foram retirados, sendo o espessamento intimal quantificado pela análise morfométrica. RESULTADOS: Na comparação entre os grupos I, II e III quanto às áreas da íntima, média e índice intimal, não foi observada variação estatisticamente significativa. Diferenças foram observadas entre os grupos em relação às áreas luminais proximais (p=0,0036 e distais (p=0,044. Através dos testes de comparação múltipla para Kruskal-Wallis foi identificada uma diferença entre os grupos I e II. Entretanto, quando essas variáveis foram controladas pelo fator peso (relação área luminal/peso, a diferença não foi mais observada. CONCLUSÕES: Nesse estudo a curto prazo, o revestimento de PTFE não esteve associado a adicional espessamento intimal além daquele promovido pelo dispositivo metálico em artérias de grande calibre e condições de alto fluxo.PURPOSE: To report an experimental study evaluating, through digital morphometry, the intimal thickening of the arterial wall after the implant of auto-expandable stainless steel stents covered or not with polytetrafluoroethylene (PTFE in the pig aorta. METHODS: In three groups of pigs a 12 F sheath was inserted in distal abdominal aorta. Group I animals (n=5 served as control. Group II animals (n=10 received an auto

  13. Impacted calculus within a urethral stent: A rare cause of urinary retention

    Directory of Open Access Journals (Sweden)

    Shanmugasundaram Rajaian

    2011-01-01

    Full Text Available An elderly male presented to the emergency department with acute urinary retention. He had poor flow of urine associated with serosanguinous discharge per urethra for 3 days duration. Earlier he underwent permanent metallic urethral stenting for post TURP bulbar urethral stricture. Plain X-ray of Pelvis showed an impacted calculus within the urethral stent in bulbar urethra. Urethrolitholapaxy was done with semirigid ureteroscope. Urethral stent was patent and well covered. Subsequently he had an uneventful recovery. We describe a unique case of acute urinary retention due to calculus impaction within a urethral stent.

  14. Sensor to detect endothelialization on an active coronary stent

    Directory of Open Access Journals (Sweden)

    Coffey Arthur C

    2010-11-01

    Full Text Available Abstract Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks.

  15. Expandable metallic stent: experimental and clinical experience in tracheobronchial tree

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Lee, Sang Young; Chung, Jin Young; Han, Young Min; Kim, Jong Soo; Choi, Ki Chul; Hong, Ki Whan; Rhee, Yang Kun [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    1991-05-15

    To maintain or reestablish an adequate airway in a patient with tracheobronchial narrowing coming from various causes, we constructed self-expanding metallic stents the same way Gianturco did, using them in 2 patients after an experimental study with rabbits. Twenty stents (10mm in diameter fully expanded and 20mm in length) were introduced into the trachea or bronchi of 10 Newzealand rabbits (weight, 2.5-3.0kg) through a 8.5 French Teflon sheath. No difficulties were encountered in the placement of the stents. At follow-up (4-12 weeks), no stent showed migration. Three rabbits died of pneumonia or bronchial perforation. Histologically, mucosal inflammation was noted at the sites of stent placement, and stent wires were covered by proliferated epithelium with intact cilia. During the last 4 months, 2 stents were used in 2 patients, one in a patient with endobronchial tuberculosis (3.0cm in length and 1.0cm in diameter fully expanded) and the other (3.0cm in length and 1.5cm in diameter) in a patient with a subglottic mass. In both patients the stents were successfully placed. Just after the placement of the stents dyspnea subsided in both patients, and there was no mortality or morbidity. These stents seem to be effective in the treatment of tracheobronchial stenosis, tracheomalacia, and airway collapse following tracheal reconstruction.

  16. Expandable metallic stent: experimental and clinical experience in tracheobronchial tree

    International Nuclear Information System (INIS)

    Song, Ho Young; Lee, Sang Young; Chung, Jin Young; Han, Young Min; Kim, Jong Soo; Choi, Ki Chul; Hong, Ki Whan; Rhee, Yang Kun

    1991-01-01

    To maintain or reestablish an adequate airway in a patient with tracheobronchial narrowing coming from various causes, we constructed self-expanding metallic stents the same way Gianturco did, using them in 2 patients after an experimental study with rabbits. Twenty stents (10mm in diameter fully expanded and 20mm in length) were introduced into the trachea or bronchi of 10 Newzealand rabbits (weight, 2.5-3.0kg) through a 8.5 French Teflon sheath. No difficulties were encountered in the placement of the stents. At follow-up (4-12 weeks), no stent showed migration. Three rabbits died of pneumonia or bronchial perforation. Histologically, mucosal inflammation was noted at the sites of stent placement, and stent wires were covered by proliferated epithelium with intact cilia. During the last 4 months, 2 stents were used in 2 patients, one in a patient with endobronchial tuberculosis (3.0cm in length and 1.0cm in diameter fully expanded) and the other (3.0cm in length and 1.5cm in diameter) in a patient with a subglottic mass. In both patients the stents were successfully placed. Just after the placement of the stents dyspnea subsided in both patients, and there was no mortality or morbidity. These stents seem to be effective in the treatment of tracheobronchial stenosis, tracheomalacia, and airway collapse following tracheal reconstruction

  17. Esophageal Stent for Refractory Variceal Bleeding: A Systemic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Xiao-Dong Shao

    2016-01-01

    Full Text Available Background. Preliminary studies suggest that covered self-expandable metal stents may be helpful in controlling esophageal variceal bleeding. Aims. To evaluate the effectiveness and safety of esophageal stent in refractory variceal bleeding in a systematic review and meta-analysis. Methods. A comprehensive literature search was conducted on PubMed, EMBASE, and Cochrane Library covering the period from January 1970 to December 2015. Data were selected and abstracted from eligible studies and were pooled using a random-effects model. Heterogeneity was assessed using I2 test. Results. Five studies involving 80 patients were included in the analysis. The age of patients ranged from 18 to 91 years. The mean duration of follow-up was 46.8 d (range, 30–60 d. The success rate of stent deployment was 96.7% (95% CI: 91.6%–99.5% and complete response to esophageal stenting was in 93.9% (95% CI: 82.2%–99.6%. The incidence of rebleeding was 13.2% (95% CI: 1.8%–32.8% and the overall mortality was 34.5% (95% CI: 24.8%–44.8%. Most of patients (87.4% died from hepatic or multiple organ failure, and only 12.6% of patients died from uncontrolled bleeding. There was no stent-related complication reported and the incidence of stent migration was 21.6% (95% CI: 4.7%–46.1%. Conclusion. Esophageal stent may be considered in patients with variceal bleeding refractory to conventional therapy.

  18. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ye Jin; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2012-10-15

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10-119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  19. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    International Nuclear Information System (INIS)

    Lee, Ye Jin; Kim, Jin Hyoung; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong

    2012-01-01

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10–119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  20. Endoscopic Stenting and Clipping for Anastomotic Stricture and Persistent Tracheoesophageal Fistula after Surgical Repair of Esophageal Atresia in an Infant

    Directory of Open Access Journals (Sweden)

    Mohammed Amine Benatta

    2014-01-01

    Full Text Available Anastomotic stricture (AS and recurrent tracheoesophageal fistula (TEF are two complications of surgical repair of esophageal atresia (EA. Therapeutic endoscopic modalities include stenting, tissue glue, and clipping for TEF and endoscopic balloon dilation bougienage and stenting for esophageal strictures. We report herein a two-month infant with both EA and TEF who benefited from a surgical repair for EA, at the third day of life. Two months later he experienced deglutition disorders and recurrent chest infections. The esophagogram showed an AS and a TEF confirmed with blue methylene test at bronchoscopy. A partially covered self-expanding metal type biliary was endoscopically placed. Ten weeks later the stent was removed. This allows for easy passage of the endoscope in the gastric cavity but a persistent recurrent fistula was noted. Instillation of contrast demonstrated a fully dilated stricture but with a persistent TEF. Then we proceeded to placement of several endoclips at the fistula site. The esophagogram confirmed the TEF was obliterated. At 12 months of follow-up, he was asymptomatic. Stenting was effective to alleviate the stricture but failed to treat the TEF. At our knowledge this is the second case of successful use of endoclips placement to obliterate recurrent TEF after surgical repair of EA in children.

  1. Stent patency in patients with distal malignant biliary obstruction receiving chemo(radio)therapy

    Science.gov (United States)

    Haal, Sylke; van Hooft, Jeanin E.; Rauws, Erik A. J.; Fockens, Paul; Voermans, Rogier P.

    2017-01-01

    Background and study aims  Recent literature suggests that chemo(radio)therapy might reduce the patency of plastic stents in patients with malignant biliary obstruction. Whether this might also be valid for other types of stents is unknown. The aim of this study was to determine the influence of chemo(radio)therapy on the patency of fully-covered self-expandable metal stents (FCSEMSs) and plastic stents. Patients and methods  We retrospectively reviewed the electronic medical records of patients with distal malignant biliary obstruction who underwent biliary stent placement between April 2001 and July 2015. Primary outcome was duration of stent patency. Secondary outcome was stent patency at 3 and 6 months. We used Kaplan–Meier survival analyses to compare stent patency rates between patients who received chemo(radio)therapy and patients who did not. Results  A total of 291 biliary stents (151 metal and 140 plastic) were identified. The median cumulative stent patency of FCSEMSs did not differ between patients receiving chemo(radio)therapy (n = 51) and those (n = 100) who did not ( P  = 0.70, log-rank test). The estimated cumulative stent patency of plastic stents was also comparable in 99 patients without and 41 patients with chemo(radio)therapy ( P  = 0.73, log-rank test). At 3 and 6 months, FCSEMS patency rates were 87 % and 83 % in patients without chemo(radio)therapy and 96 % and 83 % in patients with therapy, respectively. Plastic patency rates were 69 % and 55 % in patients without and 85 % and 39 % in patients with therapy, respectively. After 1 year, 78 % of the FCSEMSs were still patent in patients without chemo(radio)therapy and 69 % of the FCSEMSs were still patent in patients with therapy. Conclusion  Our data indicate that chemo(radio)therapy does not reduce the patency of biliary fully-covered metal and plastic stents. PMID:29090242

  2. Placement of a covered self-expandable nitinol stent for bile duct stricture that caused by ischemic injury after transcatheter arterial chemoembolization in a patient with hepatocellular carcinoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Kweon; Seo, Tae Seok; Cha, In Ho; Huh, Sik; Byun, Kwan Soo [Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2008-10-15

    The authors report here on a case of focal stricture in the common hepatic duct that was caused by ischemic bile duct injury after repeat TACE procedures for hepatocellular carcinoma, and the patient was successfully treated with a covered self-expandable nitinol stent.

  3. In-stent stenosis after stent-assisted coiling: incidence, predictors and clinical outcomes of 435 cases.

    Science.gov (United States)

    Chalouhi, Nohra; Drueding, Ross; Starke, Robert M; Jabbour, Pascal; Dumont, Aaron S; Gonzalez, L Fernando; Rosenwasser, Robert; Tjoumakaris, Stavropoula

    2013-03-01

    Neuroform and Enterprise are widely used self-expanding stents designed to treat wide-necked intracranial aneurysms. To assess the incidence, clinical significance, predictors, and outcomes of in-stent stenosis (ISS). Angiographic studies and hospital records were retrospectively reviewed for 435 patients treated between 2005 and 2011 in our institution. A multivariable regression analysis was conducted to determine the predictors of ISS. The Neuroform stent was used in 264 patients (60.7%) and the Enterprise in 171 patients (39.3%). A total of 11 patients (2.5%) demonstrated some degree of ISS during the follow-up period at a mean time point of 4.2 months (range, 2-12 months). The stenosis was mild ( 75%) in 1 patient (0.2%). No patients were symptomatic or required further intervention. There was complete ISS resolution in 2 patients, partial resolution in 2 patients, and no change in 5 patients on follow-up angiography. Patients developing ISS were significantly younger than those without ISS (40.3 vs. 54.9 years; P stent (P = .6). In multivariable analysis, younger patient age (odds ratio = 0.92; P = .008), carotid ophthalmic aneurysm location (odds ratio = 7.7; P =0.01), and carotid terminus aneurysm location (odds ratio = 8.1; P = .009) were strong independent predictors of ISS. The type of stent was not a predictive factor. Neuroform and Enterprise ISS is an uncommon, often transient, and clinically benign complication. Younger patients and those harboring anterior circulation aneurysms located at ophthalmic and carotid terminus locations are more likely to develop ISS.

  4. Endoluminal stenting for the management of leak following sleeve gastrectomy and loop duodenojejunal bypass with sleeve gastrectomy

    Directory of Open Access Journals (Sweden)

    Ying-Nan Tsai

    2018-01-01

    Full Text Available Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG (n = 5 and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG (n = 2. A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks.

  5. Endoluminal stenting for the management of leak following sleeve gastrectomy and loop duodenojejunal bypass with sleeve gastrectomy.

    Science.gov (United States)

    Tsai, Ying-Nan; Wang, Hsiu-Po; Huang, Chih-Kun; Chang, Po-Chin; Lin, I-Chang; Tai, Chi-Ming

    2018-01-01

    Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS) in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG) (n = 5) and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG) (n = 2). A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks. Copyright © 2017. Published by Elsevier Taiwan.

  6. Anastomotic leak after oesophagectomy and stent implantation: a systematic review

    Directory of Open Access Journals (Sweden)

    A.N. Kanatas

    2011-12-01

    Full Text Available Anastomotic leaks following oesophageal cancer resection have a high mortality. Stents have an established position in the palliation of dysphagia due to malignancy and in treating malignant perforation or fistula. They are increasingly used for benign conditions such as spontaneous oesophageal perforation with encouraging results. In this systematic review we examine the available evidence and attempt to define the role of stents in the management of oesophageal anastomotic leaks after resection for cancer. It is evident from the review that plastic- and metal-covered stents are an effective strategy for the treatment of anastomotic leaks. Vigilance is required as complications such as stent migration and incomplete sealing are not uncommon. Further clinical studies with greater methodological rigor in terms of sample size and study design may confirm that stents have an important contribution to make in the management of oesophageal anastomotic leak.

  7. 40 CFR 721.8095 - Silylated polyurethane.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Silylated polyurethane. 721.8095... Substances § 721.8095 Silylated polyurethane. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as a silylated polyurethane (PMN P-95-1356) is...

  8. Bio-based polyurethane prepared from Kraft lignin and modified castor oil

    Directory of Open Access Journals (Sweden)

    L. B. Tavares

    2016-11-01

    Full Text Available Current challenges highlight the need for polymer research using renewable natural sources as a substitute for petroleum-based polymers. The use of polyols obtained from renewable sources combined with the reuse of industrial residues such as lignin is an important agent in this process. Different compositions of polyurethane-type materials were prepared by combining technical Kraft lignin (TKL with castor oil (CO or modified castor oil (MCO1 and MCO2 to increase their reactivity towards diphenylmethane diisocyanate (MDI. The results indicate that lignin increases the glass transition temperature, the crosslinking density and improves the ultimate stress especially for those prepared from MCO2 and 30% lignin content from 8.2 MPa (lignin free to 23.5 MPa. Scanning electron microscopy (SEM micrographs of rupture surface after uniaxial tensile tests show ductile-to-brittle transition. The results show the possibility to develop polyurethane-type materials, varying technical grade Kraft lignin content, which cover a wide range of mechanical properties (from large elastic/low Young modulus to brittle/high Young modulus polyurethanes.

  9. Biodegradable stents in benign stenosis of the esophagus

    International Nuclear Information System (INIS)

    Manova, G.

    2013-01-01

    Full text: Introduction: Benign stenosis of the esophagus can be postcorrosion peptic or postoperative. The treatment is difficult and traditionally consists of multiple dilatations. In refractory stenosis the placement of metal self-expanding stents is disputed because requiring their subsequent removal. New experience for therapeutic decision is self- degradable stents. Manipulation is a single and not requires their removal. What you will learn: Patients indicated for the treatment with self- degradable stents are with benign stenosis not suitable for balloon dilatation or bougienage dilation. The main groups are those with postcorrosion stenosis, peptic stenosis due to untreated gastroesophageal reflux disease with different prescription as well as post-surgical and post-radiation stenosis. Self-expanding stents made by monofilament polymer of polydioxanone, whose integrity and radial force remain 6-8 weeks depending on the gastric pH are used. Stents are applied in hard guide placed in the stenosis through the working channel of gastroscopy, and they are released under X-ray control. Putting is preceded by balloon dilatation due to the large diameter of the mounted stent. During the manipulations, several difficulties are encountered, which are missing in self-expanding metal stents. Discussion: Short-term results are satisfactory - Dysphagia in the patients is overcome and they recover their normal diet. The patients reported no pain. The control inspection of the 1st month showed partial degradation of the stents. On 3rd month it is set the complete degradation. Term follow-up shows resumption of dysphagia. Conclusion: Good short-term results make the use of self-degradable stents possible alternative for the treatment of the esophagus refractory stenosis. Long-term results are contradictory, still missing long enough randomized studies on this topic

  10. Self-Expandable Metallic Stent Placement for the Palliation of Esophageal Cancer.

    Science.gov (United States)

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho Young; Kim, Pyeong Hwa; Park, Jung Hoon

    2017-07-01

    Esophageal stents have been used to palliate patients with dysphagia caused by esophageal cancer. Early rigid plastic prostheses have been associated with a high risk of complications. However, with the development of self-expanding stents, it has developed into a widely accepted method for treating malignant esophageal strictures and esophagorespiratory fistulas (ERFs). The present review covers various aspects of self-expanding metallic stent placement for palliating esophageal cancer, including its types, placement procedures, indications, contraindications, complications, and some of innovations that will become available in the future. © 2017 The Korean Academy of Medical Sciences.

  11. 40 CFR 721.8090 - Polyurethane polymer.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Polyurethane polymer. 721.8090 Section... Substances § 721.8090 Polyurethane polymer. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as a polyurethane polymer (P-94-47) is subject...

  12. Evaluation of fluency stent-grafts in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Zhao Jianbo; Li Yanhao; Chen Yong; He Xiaofeng; Zeng Qingle; Mei Quelin; Lu Wei

    2009-01-01

    Objective: To evaluate the efficacy of Fluency stent-graft (Bard Corp) in transjugular intrahepatic portosystemic shunt (TIPS). Methods: The clinical data of 21 consecutive patients treated by TIPS using Fluency stent-grafts were retrospectively reviewed. All of them were recurrent variceal bleeding secondary to portal vein hypertension, 1 was bleeding secondary to primary hepatic carcinoma with port vein thrombus, and 1 was Budd-Chiari syndrome. They were followed-up after (10.1±4.6) months (2.0 to 24.0 months). Stent-grafts patancy, portal vein pressure and liver function were recorded and compared. Results: Twenty-five stent-grafts were successfully implanted in 21 patients, 23 stent grafts were 8 mm 2 were 10 mm in diameter. The covered length of the stents varied from 6 to 8 cm. The bleeding was stopped and the portal vein pressure decreased significantly from (25.4±3.5) mm Hg to (15.4±2.8) mm Hg (t= 12.495, P 0.05). Conclusion: The Fluency stent-grafts could increase the patency of the TIPS, but its efficacy on the long-term effect and hepatic encephalopathy need further investigation. (authors)

  13. Temporary placement of covered self-expandable metallic stents in the management of benign biliary strictures.

    Science.gov (United States)

    Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka

    2012-05-01

    Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  14. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    International Nuclear Information System (INIS)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung; Lee, Yeoun Joo

    2013-01-01

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  15. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung [Dept. of University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Lee, Yeoun Joo [Dept. of Pediatrics, Pusan National University Children' s Hospital, Yangsan (Korea, Republic of)

    2013-06-15

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  16. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  17. Neutron gauging to detect voids in polyurethane

    International Nuclear Information System (INIS)

    Tsang, F.Y.; Alger, D.M.; Brugger, R.M.

    1978-01-01

    Thermal-neutron radiography and fast-neutron gauging measurements were made to evaluate the feasibility of detecting voids in a polyurethane block placed between steel plates. This sandwich of polyurethane and steel simulates the walls of a canister being designed to hold explosive devices. The polyurethane would act as a shock absorber in the canister. A large fabrication cost saving would result by casting the polyurethane, but a nondestructive testing (NDT) method is needed to determine the uniformity of the polyurethane fill. The radiography measurements used a beam of thermal neutrons, while the gauging used filtered beams of 24 keV and fission spectrum neutrons. For the 83-mm-thick polyurethane and 130-mm-thick steel matrix, the thermal-neutron radiography was able to detect only those voids equal to about one-half the polyurethane thickness. The gauging detected voids in the path of the neutron beam of a few millimetres thickness in seconds to minutes. The gauging is feasible as an NDT method for the canister application

  18. Biliary and pancreatic stenting: Devices and insertion techniques in therapeutic endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography

    Science.gov (United States)

    Mangiavillano, Benedetto; Pagano, Nico; Baron, Todd H; Arena, Monica; Iabichino, Giuseppe; Consolo, Pierluigi; Opocher, Enrico; Luigiano, Carmelo

    2016-01-01

    Stents are tubular devices made of plastic or metal. Endoscopic stenting is the most common treatment for obstruction of the common bile duct or of the main pancreatic duct, but also employed for the treatment of bilio-pancreatic leakages, for preventing post- endoscopic retrograde cholangiopancreatography pancreatitis and to drain the gallbladder and pancreatic fluid collections. Recent progresses in techniques of stent insertion and metal stent design are represented by new, fully-covered lumen apposing metal stents. These stents are specifically designed for transmural drainage, with a saddle-shape design and bilateral flanges, to provide lumen-to-lumen anchoring, reducing the risk of migration and leakage. This review is an update of the technique of stent insertion and metal stent deployment, of the most recent data available on stent types and characteristics and the new applications for biliopancreatic stents. PMID:26862364

  19. Attachment of inorganic moieties onto aliphatic polyurethanes

    Directory of Open Access Journals (Sweden)

    Eliane Ayres

    2007-06-01

    Full Text Available Polyurethanes have been used in a series of applications due basically to their versatility in terms of controlling the behavior by altering basically the type of reagents used. However, for more specific and advanced applications, such as in membranes, biomaterials and sensors, well-organized and defined chemical functionalities are necessary. In this work, inorganic functionalities were incorporated into aliphatic polyurethanes (PU having different macromolecular architectures. Polyurethanes were synthesized using a polyether diol and dicyclohexylmethane 4,4' diisocyanate (H12-MDI. Polyurethanes having carboxylic acid groups were also produced by introducing 2,2- bis (hydroxymethyl propionic acid in the polymerization process. Inorganic functionalities were inserted into polyurethanes by reacting isocyanate end capped chains with aminopropyltriethoxysilane followed by tetraethoxysilane. PU having carboxylic acid groups yielded transparent samples after the incorporation of inorganic entities, as an evidence of smaller and better dispersed inorganic entities in the polymer network. FTIR and swelling measurements showed that polyurethanes having carboxylic acid groups had inorganic domains less packed, condensed and cross-linked when compared to polyurethanes with no carboxylic acid groups. Results also suggested that the progressive incorporation of inorganic moieties in both types of polyurethanes occurred in regions previously activated with inorganic functionalities, instead of by the creation of new domains. The temperatures of thermal decomposition and glass transition were also shifted to higher temperatures when inorganic functionalities were incorporated into polyurethanes.

  20. The integrated place of tracheobronchial stents in the multidisciplinary management of large post-pneumonectomy fistulas: our experience using a novel customised conical self-expandable metallic stent.

    Science.gov (United States)

    Dutau, Hervé; Breen, David Patrick; Gomez, Carine; Thomas, Pascal Alexandre; Vergnon, Jean-Michel

    2011-02-01

    Stump dehiscence after pneumonectomy is a cause of morbidity and mortality in patients treated for non-small-cell lung carcinoma. Surgical repair remains the treatment of choice but can be postponed or contraindicated. Bronchoscopic techniques may be an option with curative intent or as a bridge towards definitive surgery. The aim of the study is to evaluate the efficacy and the outcome of a new customised covered conical self-expandable metallic stent in the management of large bronchopleural fistulas complicating pneumonectomies. A case series using chart review of non-operable patients presenting with large bronchopleural fistulas (>6mm) post-pneumonectomies as a definitive treatment with curative intent for non-small-cell lung carcinomas and requiring the use of a dedicated conical shaped stent in two tertiary referral centres. Seven patients presenting large post-pneumonectomy fistulas (between 6 and 12 mm) were included. Cessation of the air leak and clinical improvement was achieved in all the patients after stent placement. Stent-related complications (two migrations and one stent rupture) were successfully managed using bronchoscopic techniques in two patients and surgery in one. Mortality, mainly related to overwhelming sepsis, was 57%. Delayed definitive surgery was achieved successfully in three patients (43%). This case series assesses the short-term clinical efficacy of a new customised covered conical self-expandable metallic stent in the multidisciplinary management of large bronchopleural fistulas complicating pneumonectomies in patients deemed non-operable. Long-term benefits are jeopardised by infectious complications. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  1. Determination of Stent Stenosis: An In Vivo Experimental Comparison of Intravascular Ultrasound and Angiography with Histology

    International Nuclear Information System (INIS)

    Schuermann, Karl; Vorwerk, Dierk; Uppenkamp, Robert; Klosterhalfen, Bernd; Buecker, Arno; Guenther, Rolf W.

    1998-01-01

    Purpose: To compare intravascular ultrasound (IVUS) and angiography with histology in determining the degree of stent stenosis in an in vivo experiment. Methods: In 16 sheep, a total of 64 stents were implanted into the external iliac arteries. Two stents were inserted on either side. Patency was followed by angiography and IVUS. Four types of stent were used: two Dacron-covered (Cragg Endopro and heparinized Cragg Endopro) and two non-covered (Cragg and Memotherm stents). Eight animals were killed after 1 month, eight others after 6 months. Histological sections were prepared from the stented vessels. Measurements of the patent and total stent diameters determined by IVUS, angiography, and histology were compared. Results: Correlation between IVUS and angiography was 0.75, between IVUS and histology 0.77, and between angiography and histology 0.85. A mean stent stenosis of 17 ± 11% (range 0-51%) was found on angiography, of 10 ± 11% (0-46%) on IVUS, and of 20 ± 11% (4%-49%) on histology. In comparison with histology, IVUS underestimated the degree of stenosis by 10 ± 8%, and angiography underestimated it by 3 ± 6%. Resolution of IVUS was calculated to be about 0.35 mm and that of angiography to be about 0.15 mm. Conclusion: Under experimental conditions, IVUS was not superior to angiography in determining the degree of stent stenosis in long-segment stenoses of iliac artery stents, when measurements were correlated with histology. Angiography is sufficient for following the patency of iliac artery stents

  2. Polyurethane Filler for Electroplating

    Science.gov (United States)

    Beasley, J. L.

    1984-01-01

    Polyurethane foam proves suitable as filler for slots in parts electroplated with copper or nickel. Polyurethane causes less contamination of plating bath and of cleaning and filtering tanks than wax fillers used previously. Direct cost of maintenance and indirect cost of reduced operating time during tank cleaning also reduced.

  3. Primary stenting as emergency therapy in acute basilar artery occlusion

    International Nuclear Information System (INIS)

    Spreer, Joachim; Arnold, Sebastian; Klisch, Joachim; Schumacher, Martin; Els, Thomas; Hetzel, Andreas; Huppertz, Hans-Juergen; Oehm, Eckhardt

    2002-01-01

    In three patients with acute occlusion of the basilar artery intra-arterial fibrinolysis resulted in only partial recanalization and revealed severe stenosis as the underlying cause. Application of micro-stents without previous dilatation resulted in vessel re-opening. Two patients had an excellent clinical outcome. One patient died 10 days after the stroke due to brainstem infarction. Emergency primary stent application may improve the outcome in acute basilar artery occlusion, if intra-arterial thrombolysis fails to re-establish a sufficient flow. (orig.)

  4. Biodegradable airway stents in infants - Potential life-threatening pitfalls.

    Science.gov (United States)

    Sztanó, B; Kiss, G; Márai, K; Rácz, G; Szegesdi, I; Rácz, K; Katona, G; Rovó, L

    2016-12-01

    The solution of severe tracheobronchial obstructions in early childhood means a great challenge. Biodegradable stents were intended to be a minimally invasive temporary solution which may decrease the number of interventions and limit the possible complications of stenting procedures. However, our first experiences have brought out a new, - especially in childhood - potentially life-threatening complication of this concept. Five SX-ELLA biodegradable polydioxanone stents was applied in three patients because of severe tracheobronchial obstruction: congenital tracheomalacia (7 day-old), acquired tracheomalacia (10 month-old), and congenital trachea-bronchomalacia (10 month-old). The breathing of all children improved right after the procedure. We observed degradation of the stent from the 5th postoperative week which resulted in large intraluminar fragments causing significant airway obstruction: one patient died of severe pneumonia, the other baby required urgent bronchoscopy to remove the obstructing 'foreign body' from the trachea. In the third case repeated stent placements successfully maintained the tracheal lumen. Polydioxanone stents may offer an alternative to metallic or silastic stents for collapse or external compression of the trachea in children; however, large decaying fragments mean a potential risk especially in the small size pediatric airway. The fragmentation of the stent, which generally starts in the 4-6 postoperative weeks, may create large sharp pieces. These may be anchored to the mucosa and covered by crust leading to obstruction. As repeated interventions are required, we do not consider the application of biodegradable stents unambiguously advantageous. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Percutaneous Transhepatic Biliary Stenting with Uncovered Self-Expandable Metallic Stents in Patients with Malignant Biliary Obstruction - Efficacy and Survival Analysis.

    Science.gov (United States)

    Pranculis, Andrius; Kievišas, Mantas; Kievišienė, Lina; Vaičius, Artūras; Vanagas, Tomas; Kaupas, Rytis Stasys; Dambrauskas, Žilvinas

    2017-01-01

    The aim of this study was to assess short- and long-term outcomes of malignant biliary obstruction (MBO) treatment by percutaneous transhepatic biliary stenting (PTBS) with uncovered selfexpandable metallic stents (SEMS), and to identify predictors of survival. A nine-year, single-centre study from a prospectively collected database included 222 patients with inoperable MBO treated by PTBS with uncovered nitinol SEMS. Technical and clinical success rates were 95.9% and 82.4%, respectively. The total rate of postprocedural complications was 14.4%. The mean durations of the primary and secondary stent patency were 114.7±15.1 and 146.4±21.2 days, respectively. The 30-day mortality rate was 15.3% with no procedure-related deaths. The mean estimated length of survival was 143.3±20.6 days. Independent predictors increasing the risk of death included higher than 115 μmol/L serum bilirubin 2-5 days after biliary stenting (HR 3.274, P =0.019), distal (non-hilar) obstruction of the bile ducts (HR 3.711, P =0.008), Bismuth-Corlette type IV stricture (HR 2.082, P =0.008), obstruction due to gallbladder cancer (HR 31.029, P =0.012) and only partial drainage of liver parenchyma (HR 4.158, P =0.040). PTBS with uncovered SEMS is an effective and safe method for palliative treatment of MBO. Serum bilirubin higher than 115 μmol/L 2-5 days after the procedure has a significant negative impact on patients' survival. Lower survival is also determined by distal bile duct obstruction, Bismuth- Corlette type IV stricture, biliary obstruction caused by gallbladder cancer and when only partial liver drainage is applied.

  6. Stent fabric fatigue of grafts supported by Z-stents versus ringed stents: an in vitro buckling test.

    Science.gov (United States)

    Lin, Jing; Wang, Lu; Guidoin, Robert; Nutley, Mark; Song, Ge; Zhang, Ze; Du, Jia; Douville, Yvan

    2014-03-01

    Stent-grafts externally fitted with a Z-shaped stents were compared to devices fitted with ringed stents in an in vitro oscillating fatigue machine at 200 cycles per minute and a pressure of 360 mmHg for scheduled durations of up to 1 week. The devices fitted with Z-stents showed a considerably lower endurance limit to buckling compared to the controls. The contact between the apexes of adjacent Z-stents resulted in significant damage to the textile scaffolds and polyester fibers due to the sharp angle of the Z-stents. The ringed stents did not cause any fraying in the textile scaffolds.

  7. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  8. Sustained Release Drug Delivery Applications of Polyurethanes

    Directory of Open Access Journals (Sweden)

    Michael B. Lowinger

    2018-05-01

    Full Text Available Since their introduction over 50 years ago, polyurethanes have been applied to nearly every industry. This review describes applications of polyurethanes to the development of modified release drug delivery. Although drug delivery research leveraging polyurethanes has been ongoing for decades, there has been renewed and substantial interest in the field in recent years. The chemistry of polyurethanes and the mechanisms of drug release from sustained release dosage forms are briefly reviewed. Studies to assess the impact of intrinsic drug properties on release from polyurethane-based formulations are considered. The impact of hydrophilic water swelling polyurethanes on drug diffusivity and release rate is discussed. The role of pore formers in modulating drug release rate is examined. Finally, the value of assessing mechanical properties of the dosage form and approaches taken in the literature are described.

  9. Outcomes of the Use of Fully Covered Esophageal Self-Expandable Stent in the Management of Colorectal Anastomotic Strictures and Leaks

    Directory of Open Access Journals (Sweden)

    Chad J. Cooper

    2014-01-01

    Full Text Available Introduction. Colorectal anastomotic leak or stricture is a dreaded complication leading to significant morbidity and mortality. The novel use of self-expandable metal stents (SEMS in the management of postoperative colorectal anastomotic leaks or strictures can avoid surgical reintervention. Methods. Retrospective study with particular attention to the indications, operative or postoperative complications, and clinical outcomes of SEMS placement for patients with either a colorectal anastomotic stricture or leak. Results. Eight patients had SEMS (WallFlex stent for the management of postoperative colorectal anastomotic leak or stricture. Five had a colorectal anastomotic stricture and 3 had a colorectal anastomotic leak. Complete resolution of the anastomotic stricture or leak was achieved in all patients. Three had recurrence of the anastomotic stricture on 3-month flexible sigmoidoscopy follow-up after the initial stent was removed. Two of these patients had a stricture that was technically too difficult to place another stent. Stent migration was noted in 2 patients, one at day 3 and the other at day 14 after stent placement that required a larger 23 mm stent to be placed. Conclusions. The use of SEMS in the management of colorectal anastomotic leaks or strictures is feasible and is associated with high technical and clinical success rate.

  10. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2012-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  11. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents

    Directory of Open Access Journals (Sweden)

    Jing Lin

    2016-02-01

    Full Text Available Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  12. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

    Science.gov (United States)

    Lin, Jing; Guidoin, Robert; Du, Jia; Wang, Lu; Douglas, Graeham; Zhu, Danjie; Nutley, Mark; Perron, Lygia; Zhang, Ze; Douville, Yvan

    2016-02-16

    Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  13. Management of benign biliary strictures with a novel retrievable self-expandable metal stent.

    Science.gov (United States)

    Hu, Bing; Leung, Joseph W; Gao, Dao Jian; Wang, Tian Tian; Wu, Jun

    2014-03-01

    Endoscopic placement of covered self-expandable metal stent (SEMS) has gained popularity in the management of benign biliary strictures (BBS). The existing SEMS has been designed primarily to palliate malignant biliary obstruction and has a high frequency of stent migration, difficulty in retrieval and stricture recurrence after stent removal. This study aimed to design a novel retrievable SEMS dedicated to the treatment of extrahepatic BBS and evaluate its clinical efficacy and safety. A short fully covered SEMS (FCSEMS) with a retrieval lasso was designed for the specific treatment of BBS. A total of 45 patients with segmental extrahepatic BBS were included in this study. The stent was placed entirely inside the bile duct with only the retrieval lasso extending from the papilla. The stents were recommended to be in situ for 6 to 12 months before removal. The FCSEMS was successfully placed in all 45 patients. In all, 33 patients had their FCSEMS successfully removed after a mean period of 8.6 ± 3.7 (range 2-15.5) months. Stent migration occurred in 9.1% of the patients. During a mean follow-up of 18.9 months after stent removal, recurrent stricture was found in 2 (6.1%) patients and was successfully treated with a second FCSEMS. Overall, the strictures resolved in 30/33 (90.9%) patients. Intraductal placement of a short FCSEMS is suitable for the treatment of segmental extrahepatic BBS. This new removable design offered prolonged stenting and drainage for BBS for up to one year with minimal complications. © 2013 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  14. Stent

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Stent URL of this page: //medlineplus.gov/ency/article/002303.htm Stent To use the sharing features on this page, please enable JavaScript. A stent is a tiny tube placed into a hollow structure in your ...

  15. Symptomatic stent cast.

    LENUS (Irish Health Repository)

    Keohane, John

    2012-02-03

    Biliary stent occlusion is a major complication of endoscopic stent insertion and results in repeat procedures. Various theories as to the etiology have been proposed, the most frequently studied is the attachment of gram negative bacteria within the stent. Several studies have shown prolongation of stent patency with antibiotic prophylaxis. We report the case of stent occlusion from a cast of a previously inserted straight biliary stent; a "stent cast" in an 86-year-old woman with obstructive jaundice. This was retrieved with the lithotrypter and she made an uneventful recovery. This is the first reported case of a biliary stent cast.

  16. 40 CFR 721.8082 - Polyester polyurethane acrylate.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Polyester polyurethane acrylate. 721... Substances § 721.8082 Polyester polyurethane acrylate. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as polyester polyurethane acrylate...

  17. Injectable Polyurethane Composite Scaffolds Delay Wound Contraction and Support Cellular Infiltration and Remodeling in Rat Excisional Wounds

    Science.gov (United States)

    Adolph, Elizabeth J.; Hafeman, Andrea E.; Davidson, Jeffrey M.; Nanney, Lillian B.; Guelcher, Scott A.

    2011-01-01

    Injectable scaffolds present compelling opportunities for wound repair and regeneration due to their ability to fill irregularly shaped defects and deliver biologics such as growth factors. In this study, we investigated the properties of injectable polyurethane biocomposite scaffolds and their application in cutaneous wound repair using a rat excisional model. The scaffolds have a minimal reaction exotherm and clinically relevant working and setting times. Moreover, the biocomposites have mechanical and thermal properties consistent with rubbery elastomers. In the rat excisional wound model, injection of settable biocomposite scaffolds stented the wounds at early time points, resulting in a regenerative rather than a scarring phenotype at later time points. Measurements of wound width and thickness revealed that the treated wounds were less contracted at day 7 compared to blank wounds. Analysis of cell proliferation and apoptosis showed that the scaffolds were biocompatible and supported tissue ingrowth. Myofibroblast formation and collagen fiber organization provided evidence that the scaffolds have a positive effect on extracellular matrix remodeling by disrupting the formation of an aligned matrix under elevated tension. In summary, we have developed an injectable biodegradable polyurethane biocomposite scaffold that enhances cutaneous wound healing in a rat model. PMID:22105887

  18. High modulus biodegradable polyurethanes for applications in cardiovascular stents: Evaluation of in-vitro degradation and cell viability

    Directory of Open Access Journals (Sweden)

    Melissa eSagarito

    2015-05-01

    Full Text Available We have recently reported the mechanical properties and hydrolytic degradation behaviour of a series of NovoSorb™ [1] biodegradable polyurethanes (PUs prepared by varying the hard segment (HS weight percentage from 60-100. In this study the in-vitro degradation behaviour of the PUs with and without extracellular matrix (ECM coating was investigated under accelerated hydrolytic degradation (phosphate buffer saline; PBS/70°C conditions to allow complete degradation. The mass loss at different time intervals and the effect of aqueous degradation products on the viability and growth of Human Umbilical Vein Endothelial Cells (HUVEC were examined.The results showed that for most PUs in the series the degradation medium turned acidic and the extent of this was dependent on the HS percentage. As the HS decreased, a drop in pH was observed, suggesting that the by-products of soft segment (SS degradation causing the solution to be acidic. Most of the samples were completely eroded by 18 weeks, except PU containing more than 70% HS which only showed partial degradation with no significant change in appearance. The cytotoxicity tests on HUVEC cells of the aqueous extracts obtained after 18 weeks incubation showed that toxicity was dependent on 3 factors: dose, percentage of HS and degradation time. HUVEC growth is similar to but not identical to that observed with tissue culture polystyrene (TCPS standard. The results from this in-vitro cytotoxicity study suggest that the mixture of degradation products formed during the accelerated degradation of this PU series are not toxic to cells under the experimental conditions used.

  19. Expandable metallic stents: An experimental study in the nasolacrimal systems of dogs

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Lee, Jeong Min; Han, Young Min; Hwang, Eui Il; Chung, Gyung Ho; Shon, Myung Hee; Kim, Chong Soo; Choi, Ki Chul [Chonbuk National University Medical School, Chonju(Korea, Republic of)

    1993-11-15

    Balloon dacryocystoplasty has been reported to be a safe, easy and effective nonoperative treatment for nasolacrimal stenosis. The results were not encouraging, however, because of its high failure and recurrence rates. To evaluate the feasibility of using modified Gianturco expandable metallic stents for maintenance of the dilated nasolacrimal system(NLS), 20 stents of 3 mm in diameter and 10 mm long were placed in 20 nasolacrimal ducts of 10 dogs for 1 month to 10 months. It was more difficult to introduce the stents into the proximal portion(A) of the NLS than into the distal portion(B) due to the narrow and bony canal of the A portion. Twenty stents showed no migration in follow-up studies of up to 10 months. One complete occlusion occurred in a stent placed in A portion. Autopsy studies showed stents were covered with epithelium within 2 months after placement. Our experience suggest that the placement of Gianturco self-expandable stents may be a useful method of dilating and maintaining the luminal diameter of the NLS, although care must be taken to select the proper stent size.

  20. Expandable metallic stents: An experimental study in the nasolacrimal systems of dogs

    International Nuclear Information System (INIS)

    Song, Ho Young; Lee, Jeong Min; Han, Young Min; Hwang, Eui Il; Chung, Gyung Ho; Shon, Myung Hee; Kim, Chong Soo; Choi, Ki Chul

    1993-01-01

    Balloon dacryocystoplasty has been reported to be a safe, easy and effective nonoperative treatment for nasolacrimal stenosis. The results were not encouraging, however, because of its high failure and recurrence rates. To evaluate the feasibility of using modified Gianturco expandable metallic stents for maintenance of the dilated nasolacrimal system(NLS), 20 stents of 3 mm in diameter and 10 mm long were placed in 20 nasolacrimal ducts of 10 dogs for 1 month to 10 months. It was more difficult to introduce the stents into the proximal portion(A) of the NLS than into the distal portion(B) due to the narrow and bony canal of the A portion. Twenty stents showed no migration in follow-up studies of up to 10 months. One complete occlusion occurred in a stent placed in A portion. Autopsy studies showed stents were covered with epithelium within 2 months after placement. Our experience suggest that the placement of Gianturco self-expandable stents may be a useful method of dilating and maintaining the luminal diameter of the NLS, although care must be taken to select the proper stent size

  1. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    Science.gov (United States)

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Endoscopic removal and trimming of distal self-expandable metallic biliary stents

    Science.gov (United States)

    Ishii, Kentaro; Itoi, Takao; Sofuni, Atsushi; Itokawa, Fumihide; Tsuchiya, Takayoshi; Kurihara, Toshio; Tsuji, Shujiro; Ikeuchi, Nobuhito; Umeda, Junko; Moriyasu, Fuminori; Tsuchida, Akihiko

    2011-01-01

    AIM: To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents (SEMS). METHODS: All SEMS had been placed for distal biliary strictures. Twenty-seven endoscopic procedures were performed in 19 patients in whom SEMS (one uncovered and 18 covered) removal had been attempted, and 8 patients in whom stent trimming using argon plasma coagulation (APC) had been attempted at Tokyo Medical University Hospital. The APC settings were: voltage 60-80 W and gas flow at 1.5 L/min. RESULTS: The mean stent indwelling period for all patients in whom stent removal had been attempted was 113.7 ± 77.6 d (range, 8-280 d). Of the 19 patients in whom removal of the SEMS had been attempted, the procedure was successful in 14 (73.7%) without procedure-related adverse events. The indwelling period in the stent removable group was shorter than that in the unremovable group (94.9 ± 71.5 d vs 166.2 ± 76.2 d, P = 0.08). Stent trimming was successful for all patients with one minor adverse event consisting of self-limited hemorrhage. Trimming time ranged from 11 to 16 min. CONCLUSION: Although further investigations on larger numbers of cases are necessary to accumulate evidence, the present data suggested that stent removal and stent trimming is feasible and effective for stent-related complications. PMID:21677835

  3. Circumferential Stent Fracture: Novel Detection and Treatment with the Use of StentBoost

    OpenAIRE

    Ramegowda, Raghu T.; Chikkaswamy, Srinivas B.; Bharatha, Ashalatha; Radhakrishna, Jayashree; Krishnanaik, Geetha B.; Nanjappa, Manjunath C.; Panneerselvam, Arunkumar

    2012-01-01

    Circumferential stent fracture is extremely uncommon, and in rare cases, it can cause stent thrombosis. Recognizing stent fracture can be difficult on conventional fluoroscopy because of poor stent radiopacity. We found that StentBoost image acquisition yields improved visibility of stent struts, enabling the identification of stent fracture and the precise positioning of new stents over previously stented segments.

  4. Metallic ureteral stents in malignant ureteral obstruction: clinical factors predicting stent failure.

    Science.gov (United States)

    Chow, Po-Ming; Hsu, Jui-Shan; Huang, Chao-Yuan; Wang, Shuo-Meng; Lee, Yuan-Ju; Huang, Kuo-How; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liang, Po-Chin

    2014-06-01

    To provide clinical outcomes of the Resonance metallic ureteral stent in patients with malignant ureteral obstruction, as well as clinical factors predicting stent failure. Cancer patients who have received Resonance stents from July 2009 to March 2012 for ureteral obstruction were included for chart review. Stent failure was detected by clinical symptoms, image studies, and renal function tests. Survival analysis for stent duration was used to estimate patency rate and factors predicting stent failure. A total of 117 stents were inserted successfully into 94 ureteral units in 79 patients. There were no major complications. These stents underwent survival analysis and proportional hazard regression. The median duration for the stents was 5.77 months. In multivariate analysis, age (P=0.043), preoperative serum creatinine level (P=0.0174), and cancer type (P=0.0494) were significant factors associated with stent failure. Cancer treatment before and after stent insertion had no effect on stent duration. Resonance stents are effective and safe in relieving malignant ureteral obstructions. Old age and high serum creatinine level are predictors for stent failure. Stents in patients with lower gastrointestinal cancers have longer functional duration.

  5. 40 CFR 721.9959 - Polyurethane polymer (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Polyurethane polymer (generic). 721... Substances § 721.9959 Polyurethane polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as a polyurethane polymer (PMN P-01...

  6. Biodegradable polyurethane nanocomposites containing dexamethasone for ocular route

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues da Silva, Gisele [Federal University of Sao Joao Del Rei, School of Pharmacy, Divinopolis, Minas Gerais (Brazil); Silva-Cunha, Armando da [Federal University of Minas Gerais, School of Pharmacy, Belo Horizonte, Minas Gerais (Brazil); Behar-Cohen, Francine [INSERM, Physiopathology of ocular diseases: Therapeutic innovations, Institut des Cordeliers, Paris (France); Laboratoire d' Innovations Therapeutiques, Fondation Rothschild, Paris (France); Universite Rene Descartes, Hotel Dieu University Hospital, Paris (France); Ayres, Eliane [Federal University of Minas Gerais, Department of Metallurgical and Materials Engineering, Belo Horizonte, Minas Gerais (Brazil); Orefice, Rodrigo L., E-mail: rorefice@demet.ufmg.br [Federal University of Minas Gerais, Department of Metallurgical and Materials Engineering, Belo Horizonte, Minas Gerais (Brazil)

    2011-03-12

    The treatment of posterior segment ocular diseases, such as uveitis, by using eye drops and oral drugs is usually not effective due to the body's natural barriers to drug penetration. In this study, ocular implants to treat uveitis were synthesized by incorporating dexamethasone acetate, an important type of corticoid used in the treatment of some uveitis, into a biodegradable polyurethane containi clay nanoparticles. Biodegradable polyurethane nanocomposites having poly(caprolactone) oligomers as soft segments were obtained by delaminating clay particles within a polyurethane aqueous dispersion. The drug was incorporated into the polymer by dispersing it in the waterborne polyurethane followed by a drying step. Nanoparticles derived from clay were demonstrated to be able to tailor the mechanical properties of polyurethanes to achieve values that can match the properties of ocular soft tissues. Infrared spectra (FTIR) showed that the presence of clay particles was able to change the microphase separation process typical of polyurethanes. X-ray diffraction and small angle x-ray scattering (SAXS) results were explored to show that the incorporation of both dexamethasone acetate and nanocomponents derived from clay led to a less defined two-phase polyurethane. The presence of clay nanoparticles increased the rate of drug release measured in vitro. Human retinal pigment epithelial cells (ARPE-19) were cultured in contact with polyurethanes and polyurethane nanocomposites, and the viability of them (evaluated by using MTT assay after 7 days) showed that no toxic components were released from polyurethanes containing no drugs during the test.

  7. Biodegradable polyurethane nanocomposites containing dexamethasone for ocular route

    International Nuclear Information System (INIS)

    Rodrigues da Silva, Gisele; Silva-Cunha, Armando da; Behar-Cohen, Francine; Ayres, Eliane; Orefice, Rodrigo L.

    2011-01-01

    The treatment of posterior segment ocular diseases, such as uveitis, by using eye drops and oral drugs is usually not effective due to the body's natural barriers to drug penetration. In this study, ocular implants to treat uveitis were synthesized by incorporating dexamethasone acetate, an important type of corticoid used in the treatment of some uveitis, into a biodegradable polyurethane containi clay nanoparticles. Biodegradable polyurethane nanocomposites having poly(caprolactone) oligomers as soft segments were obtained by delaminating clay particles within a polyurethane aqueous dispersion. The drug was incorporated into the polymer by dispersing it in the waterborne polyurethane followed by a drying step. Nanoparticles derived from clay were demonstrated to be able to tailor the mechanical properties of polyurethanes to achieve values that can match the properties of ocular soft tissues. Infrared spectra (FTIR) showed that the presence of clay particles was able to change the microphase separation process typical of polyurethanes. X-ray diffraction and small angle x-ray scattering (SAXS) results were explored to show that the incorporation of both dexamethasone acetate and nanocomponents derived from clay led to a less defined two-phase polyurethane. The presence of clay nanoparticles increased the rate of drug release measured in vitro. Human retinal pigment epithelial cells (ARPE-19) were cultured in contact with polyurethanes and polyurethane nanocomposites, and the viability of them (evaluated by using MTT assay after 7 days) showed that no toxic components were released from polyurethanes containing no drugs during the test.

  8. The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Alparslan, Burcu, E-mail: burcu.alparslan@gmail.com [Yozgat State Hospital, Radiology Clinic (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Uludag University Faculty of Medicine, Department of Radiology (Turkey); Eritmen, Ulku Turpcu, E-mail: drulkutur@hotmail.com.tr [Special Eregli Anatolia Hospital, Radiology Clinic (Turkey); Duran, Selcen, E-mail: selcenduran16@hotmail.com [Yerkoy State Hospital, Neurology Clinic (Turkey); Ozkaya, Guven, E-mail: ozkaya@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Biostatistics (Turkey); Hakyemez, Bahattin, E-mail: bhakyemez@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Radiology (Turkey)

    2016-04-15

    PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

  9. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  10. Airway stents

    Science.gov (United States)

    Keyes, Colleen

    2018-01-01

    Stents and tubes to maintain the patency of the airways are commonly used for malignant obstruction and are occasionally employed in benign disease. Malignant airway obstruction usually results from direct involvement of bronchogenic carcinoma, or by extension of carcinomas occurring in the esophagus or the thyroid. External compression from lymph nodes or metastatic disease from other organs can also cause central airway obstruction. Most malignant airway lesions are surgically inoperable due to advanced disease stage and require multimodality palliation, including stent placement. As with any other medical device, stents have significantly evolved over the last 50 years and deserve an in-depth understanding of their true capabilities and complications. Not every silicone stent is created equal and the same holds for metallic stents. Herein, we present an overview of the topic as well as some of the more practical and controversial issues surrounding airway stents. We also try to dispel the myths surrounding stent removal and their supposed use only in central airways. At the end, we come to the long-held conclusion that stents should not be used as first line treatment of choice, but after ruling out the possibility of curative surgical resection or repair. PMID:29707506

  11. Preparation of collagen/polyurethane/knitted silk as a composite scaffold for tendon tissue engineering.

    Science.gov (United States)

    Sharifi-Aghdam, Maryam; Faridi-Majidi, Reza; Derakhshan, Mohammad Ali; Chegeni, Arash; Azami, Mahmoud

    2017-07-01

    The main objective of this study was to prepare a hybrid three-dimensional scaffold that mimics natural tendon tissues. It has been found that a knitted silk shows good mechanical strength; however, cell growth on the bare silk is not desirable. Hence, electrospun collagen/polyurethane combination was used to cover knitted silk. A series of collagen and polyurethane solutions (4%-7% w/v) in aqueous acetic acid were prepared and electrospun. According to obtained scanning electron microscopy images from pure collagen and polyurethane nanofibers, concentration was set constant at 5% (w/v) for blend solutions of collagen/polyurethane. Afterward, blend solutions with the weight ratios of 75/25, 50/50 and 25/75 were electrospun. Scanning electron microscopy images demonstrated the smooth and uniform morphology for the optimized nanofibers. The least fibers diameter among three weight ratios was found for collagen/polyurethane (25/75) which was 100.86 ± 40 nm and therefore was selected to be electrospun on the knitted silk. Attenuated total reflectance-Fourier transform infrared spectra confirmed the chemical composition of obtained electrospun nanofibers on the knitted silk. Tensile test of the specimens including blend nanofiber, knitted silk and commercial tendon substitute examined and indicated that collagen/polyurethane-coated knitted silk has appropriate mechanical properties as a scaffold for tendon tissue engineering. Then, Alamar Blue assay of the L929 fibroblast cell line seeded on the prepared scaffolds demonstrated appropriate viability of the cells with a significant proliferation on the scaffold containing more collagen content. The results illustrate that the designed structure would be promising for being used as a temporary substitute for tendon repair.

  12. An experimental study on the influence of the intravascular gianturco type stents on the vascular structures

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Yeon Hyeon [Sejong General Hospital, Bucheon (Korea, Republic of); Park, Jae Hyung; Han, Joon Koo; Han, Man Chung; Kim, Chu Wan [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1991-07-15

    Twenty-seven Gianturco-type self-expandable stainless steel intravascular stents were placed into the infrarenal abdominal aortas (n=17) and inferior venae cavae (n=10) in 14 mongrel dogs. In 8 aortas, stents were delivered after balloon catheter-induced denudation of the intima, and in 4 out of the 8 aortas, the stents were also placed into the normal sites to compare the neointimal thickness of the normal and denuded sites. Angiography, light microscopic, and scanning electron microscopic examinations were performed after 1 week (n=1), 2 weeks (n=6), 3 weeks (n=5), and 6 weeks (n=2). The patency rate and thrombosis rate were 100% and 35% in the aortas and 100% and 60% in the inferior venae cavae. The aortic stent wires were covered with thin fibrinous membrane after 1 week. Nearly complete transparent neointimal covering was found in the aortas and caval veins after 2 weeks. There was no significant difference in intimal thickness between the denuded and normal aortas after 2 weeks ({rho} =0.51) and 3 weeks ({rho} =0.56). In 4 dogs with caval vein stents, there was evidence of hemorrhage infarction in the lungs. The thrombosis rate of 12 stents with a stent-artery ratio (SAR) of 1.5 or higher was 41%, while there was no thrombus on the 4 stents with SAR 1.2 or lower, except for 1 specimen after 1 week. It is suggested that stents with SAR 1.2 or lower are more suitable. The high thrombosis rate of the inferior venae cavae may be related with slow blood flow.

  13. Potential mechanisms of in-stent occlusion in the femoropopliteal artery: an angioscopic assessment.

    Science.gov (United States)

    Ishihara, Takayuki; Iida, Osamu; Okamoto, Shin; Fujita, Masashi; Masuda, Masaharu; Nanto, Kiyonori; Shiraki, Tatsuya; Kanda, Takashi; Tsujimura, Takuya; Okuno, Shota; Yanaka, Koji; Uematsu, Masaaki

    2017-10-01

    Although stent implantation has become widespread for the treatment of patients with peripheral artery disease with femoropopliteal (FP) lesions, in-stent restenosis, especially in-stent occlusion (ISO), remains as a major concern for refractory recurrence. Furthermore, the mechanisms of ISO in FP lesions have not been well elucidated. We performed angioscopy for 6 lesions (bare-metal stent: 3, drug-eluting stent: 3) from 5 patients (mean age 74 ± 10 years, male 40 %) with ISO in the FP artery immediately after wire-passing or thrombus aspiration. The presence of thrombus as well as the presence and location of organic stenosis were evaluated. Median duration from stent implantation to angioscopic evaluation was 1099.5 (514.5-2272.5) days, while the duration from recurrence of symptoms to angioscopic evaluation was 45 (5.75-60) days. Mixed thrombi were observed in all stents. Organic stenosis was detected at the proximal edge of the stents in 5 lesions. Organic stenosis was observed at the overlapping segment of the stent in one lesion. The distal edge of the stents could be evaluated in 3 lesions, and all of them showed organic stenosis at the site. Mixed thrombi and organic stenosis were observed in all stents. Partial development of organic stenosis in a stent followed by thrombus formation may be the potential mechanism of the development of ISO in the FP artery though the sample size of this study was small and it had no serial angioscopic data so that we should consider it as preliminary one at best.

  14. Recurrence of Subacute Stent Thrombosis and In-Stent Restenosis during Five Months after Stent Implantation in the LAD. A Case Report.

    OpenAIRE

    島田, 弘英; 大和, 眞史; 櫻井, 俊平; 疋田, 博之; 池田, 修一

    2001-01-01

    A coronary stent was deployed in the left anterior descending artery of an 82-year-old woman with unstable angina.Recurrence of subacute stent thrombosis and in-stent restenosis occurred frequently during the five months after initial stent implantation.Balloon angioplasty and cutting balloon angioplasty failed to prevent these complications,but they ceased after re-stenting in the initial stent.In this case,tissue protrusion through the stent strut, deformation of the coil stent and inadequa...

  15. A newly-designed temporary cardia stent for the treatment of achalasia:an experimental study in canine models

    International Nuclear Information System (INIS)

    Kuang Xiaochun; Cheng Yingsheng; Zhu Yueqi; Li Feng; Wang Weiguo

    2010-01-01

    Objective: To assess the efficacy and safety of a newly-designed temporary covered cardia stent for the treatment of achalasia in canine models and to investigate the histopathological changes at different points of follow-up time after the stent was removed. Methods: The canine achalasia model was created by injecting benzyl-dimethyl-tetradecyl ammonium chloride (BAC) circumferentially into the lower esophageal sphincter (LES) of the dogs. Twenty-four dogs with achalasia were randomly and equally divided into two groups with 12 dogs in each group: control group (using routine esophageal stents) and study group (using newly-designed temporary covered cardia stents). Under fluoroscopic guidance stents were implanted in the esophagus and were taken away from the esophagus 4 days after stent insertion in experimental dogs of both groups. LES pressures and timed barium esophagography (TBE) were performed in all dogs before and immediately after the stenting procedure, as well as at one week, 3 and 6 months after the stent was removed. Every three dogs were sacrificed each time at one week, 3 and 6 months after the stent was removed. The esophageal cardia was excised and sent for pathological examination. Results: All animals well tolerated the stent insertion / removal and the follow-up procedures. No severe complications such as esophageal perforation occurred. Comparison between two groups showed that stent migration occurrence was much lower in study group (n = 1) than that in control group (n = 5). The reduction of LES pressures in study group was more significant in comparison with control group (at 6-month follow-up, P = 0.027). The difference in barium column product (height x width) between 0-min and 5-min TBE was statistically significant in study group (at 3-month follow-up, P = 0.009). Integrated analysis of multi-comparison for LES pressures among subgroups of each group revealed that the dogs in study group exhibited better outcomes than the dogs in

  16. StentBoost Visualization for the Evaluation of Coronary Stent Expansion During Percutaneous Coronary Interventions

    OpenAIRE

    Cura, Fernando; Albertal, Mariano; Candiello, Alfonsina; Nau, Gerardo; Bonvini, Victor; Tricherri, Hernan; Padilla, Lucio T.; Belardi, Jorge A.

    2013-01-01

    Introduction Inadequate stent implantation is associated with stent thrombosis and restenosis. StentBoost can enhance stent visualization and evaluate stent expansion. Currently, there are limited comparison studies between StentBoost and intravascular ultrasound (IVUS). We aimed to test the correlation and agreement between IVUS and StentBoost measurements. Methods From December 2010 to December 2011, 38 patients (54 stents) were analyzed using IVUS and StentBoost. Minimal stent diameter and...

  17. Stent malapposition, as a potential mechanism of very late stent thrombosis after bare-metal stent implantation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Higuma, Takumi, E-mail: higuma@cc.hirosaki-u.ac.jp; Abe, Naoki; Hanada, Kenji; Yokoyama, Hiroaki; Tomita, Hirofumi; Okumura, Ken

    2014-04-15

    A 90-year-old man was admitted to our hospital with acute ST-segment elevation myocardial infarction. He had a history of post-infarction angina pectoris 79 months ago and had a bare-metal stent (BMS) implanted in the proximal left anterior descending artery at our hospital. Emergent coronary angiography demonstrated thrombotic occlusion in the previously stented segment. After catheter thrombectomy, antegrade flow was restored, but 90% stenosis with haziness persisted in the proximal and distal portions of the previously stented segment. Intravascular ultrasound imaging showed interstrut cavities or stent malapposition at the proximal and distal sites of stented segment. In close proximity to the sites, residual thrombi were also observed. Optical coherence tomography (OCT) demonstrated neither lipid-laden neointimal tissue nor rupture but clearly demonstrated residual thrombus adjacent to the malapposed region in addition to the stent malapposition. PCI with balloon was successfully performed and stent apposition was confirmed by OCT. Stent malapposition is an unusual mechanism of very late stent thrombosis after BMS implantation. OCT can clearly reveal the etiology of stent thrombosis.

  18. Recurrent airway obstructions in a patient with benign tracheal stenosis and a silicone airway stent: a case report

    Science.gov (United States)

    Sriram, KB; Robinson, PC

    2008-01-01

    Airway stents (silicone and metal stents) are used to treat patients with benign tracheal stenosis, who are symptomatic and in whom tracheal surgical reconstruction has failed or is not appropriate. However airway stents are often associated with complications such as migration, granuloma formation and mucous hypersecretion, which cause significant morbidity, especially in patients with benign tracheal stenosis and relatively normal life expectancy. We report a patient who had frequent critical airway obstructions over 8 years due to granuloma and mucus hypersecretion in a silicone airway stent. The problem was resolved when the silicone stent was removed and replaced with a covered self expanding metal stent. PMID:18840299

  19. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis. From western denmark heart registry

    DEFF Research Database (Denmark)

    Jensen, Jesper; Jensen, Lisette Okkels; Terkelsen, Christian Juhl

    2012-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  20. Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients.

    Science.gov (United States)

    Tada, Tomohisa; Byrne, Robert A; Simunovic, Iva; King, Lamin A; Cassese, Salvatore; Joner, Michael; Fusaro, Massimiliano; Schneider, Simon; Schulz, Stefanie; Ibrahim, Tareq; Ott, Ilka; Massberg, Steffen; Laugwitz, Karl-Ludwig; Kastrati, Adnan

    2013-12-01

    This study sought to compare the risk of stent thrombosis among patients treated with bare-metal stents (BMS), first-generation drug-eluting stents (G1-DES), and second-generation drug-eluting stents (G2-DES) for a period of 3 years. In patients undergoing coronary stenting, there is a scarcity of long-term follow-up data on cohorts large enough to compare rates of stent thrombosis across the stent generations. A total of 18,334 patients undergoing successful coronary stent implantation from 1998 to 2011 at 2 centers in Munich, Germany, were included in this study. Patients were stratified into 3 groups according to treatment with BMS, G1-DES, and G2-DES. The cumulative incidence of definite stent thrombosis at 3 years was 1.5% with BMS, 2.2% with G1-DES, and 1.0% with G2-DES. On multivariate analysis, G1-DES compared with BMS showed a significantly higher risk of stent thrombosis (odds ratio [OR]: 2.05; 95% confidence interval [CI]: 1.47 to 2.86; p stent thrombosis compared with BMS (OR: 0.82; 95% CI: 0.56 to 1.19; p = 0.30). Beyond 1 year, the risk of stent thrombosis was significantly increased with G1-DES compared with BMS (OR: 4.72; 95% CI: 2.01 to 11.1; p stenting, compared with BMS, there was a significant excess risk of stent thrombosis at 3 years with G1-DES, driven by an increased risk of stent thrombosis events beyond 1 year. G2-DES were associated with a similar risk of stent thrombosis compared with BMS. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE

    Directory of Open Access Journals (Sweden)

    M. N. Kornilov

    2013-01-01

    Full Text Available Aim. The aim of this study focuses on the first experience with self-expandable stents, analysis of its efficacy and safety in the treatment of anastomotic strictures after liver transplantation. Materials and methods. There’re 136 liver transplantations performed from 2004 till 2012. To correct anastomotic strictures we’ve used only the self-expandable coated nitinol stent. We performed stenting in 7 recipient. Result. In 131 liver transplant recipients incidence of biliary strictures has been 5.3%. All of 5 patients have been managed by retrograde or antegrade way. Conclusion. Our first experience demonstrate efficacy and safety of the used tecniques up to 24 months. The analysis of more long-term results is required. 

  2. Characterization and properties of sepiolite/polyurethane nanocomposites

    International Nuclear Information System (INIS)

    Chen Hongxiang; Zheng Maosheng; Sun Hongying; Jia Qingming

    2007-01-01

    In situ polymerization method is employed to prepare sepiolite/polyurethane nanocomposite. The morphology and the dispersion of sepiolite in polyurethane have been characterized by X-ray diffraction, scanning electron microscope, transmission electron microscope and Fourier transform infrared spectroscopy. The results show the sepiolite is dispersed homogeneously in the polyurethane matrix at a nanometer scale. The tensile test shows that the tensile strength and elongation at break for the nanocomposites increase with the addition of sepiolite as compared to those of the pure polyurethane. The TGA analysis reveals that the addition of nanofillers results in the higher thermal stability

  3. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)

    2011-08-15

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  4. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  5. Percutaneous Transhepatic Biliary Stenting with Uncovered Self-Expandable Metallic Stents in Patients with Malignant Biliary Obstruction – Efficacy and Survival Analysis

    Science.gov (United States)

    Pranculis, Andrius; Kievišienė, Lina; Vaičius, Artūras; Vanagas, Tomas; Kaupas, Rytis Stasys; Dambrauskas, Žilvinas

    2017-01-01

    Summary Background The aim of this study was to assess short- and long-term outcomes of malignant biliary obstruction (MBO) treatment by percutaneous transhepatic biliary stenting (PTBS) with uncovered selfexpandable metallic stents (SEMS), and to identify predictors of survival. Material/Methods A nine-year, single-centre study from a prospectively collected database included 222 patients with inoperable MBO treated by PTBS with uncovered nitinol SEMS. Results Technical and clinical success rates were 95.9% and 82.4%, respectively. The total rate of postprocedural complications was 14.4%. The mean durations of the primary and secondary stent patency were 114.7±15.1 and 146.4±21.2 days, respectively. The 30-day mortality rate was 15.3% with no procedure-related deaths. The mean estimated length of survival was 143.3±20.6 days. Independent predictors increasing the risk of death included higher than 115 μmol/L serum bilirubin 2–5 days after biliary stenting (HR 3.274, P=0.019), distal (non-hilar) obstruction of the bile ducts (HR 3.711, P=0.008), Bismuth-Corlette type IV stricture (HR 2.082, P=0.008), obstruction due to gallbladder cancer (HR 31.029, P=0.012) and only partial drainage of liver parenchyma (HR 4.158, P=0.040). Conclusions PTBS with uncovered SEMS is an effective and safe method for palliative treatment of MBO. Serum bilirubin higher than 115 μmol/L 2–5 days after the procedure has a significant negative impact on patients’ survival. Lower survival is also determined by distal bile duct obstruction, Bismuth– Corlette type IV stricture, biliary obstruction caused by gallbladder cancer and when only partial liver drainage is applied. PMID:29662569

  6. Efficacy of Endoscopic Over 3-branched Partial Stent-in-Stent Drainage Using Self-expandable Metallic Stents in Patients With Unresectable Hilar Biliary Carcinoma.

    Science.gov (United States)

    Uchida, Daisuke; Kato, Hironari; Muro, Shinichiro; Noma, Yasuhiro; Yamamoto, Naoki; Horiguchi, Shigeru; Harada, Ryo; Tsutsumi, Koichiro; Kawamoto, Hirofumi; Okada, Hiroyuki; Yamamoto, Kazuhide

    2015-07-01

    The treatment of biliary stricture is crucially important for continuing stable chemotherapy for unresectable biliary carcinoma; however, there is no consensus regarding the use of hilar biliary drainage. In this study, we examined the efficacy of endoscopic over 3-branched biliary drainage using self-expandable metallic stents (SEMSs) in patients with unresectable malignant hilar biliary stricture (HBS). A total of 77 patients with unresectable HBS treated with a SEMS and chemotherapy were retrospectively reviewed. There were 59 patients with cholangiocarcinoma and 18 patients with gallbladder carcinoma. The patients were divided into 2 groups (4- or 3-branched group and 2- or 1-branched group) and compared with respect to the duration of stent patency and overall survival. A comparison of the patients' baseline characteristics showed no significant differences between the 4- or 3-branched group and the 2- or 1-branched group. Neither the duration of patency nor survival time exhibited significant differences between the 2 groups, although, among the patients achieving disease control , the duration of patency period and survival time of the 4- or 3-branched group were significantly higher than those observed in the 2- or 1-branched group (P=0.0231 and 0.0466). The use of endoscopic over 3-branched biliary drainage with a SEMS may improve the duration of patency in patients with HBS.

  7. Endoscopic bilateral stent-in-stent placement for malignant hilar obstruction using a large cell type stent.

    Science.gov (United States)

    Park, Jin Myung; Lee, Sang Hyub; Chung, Kwang Hyun; Jang, Dong Kee; Ryu, Ji Kon; Kim, Yong-Tae; Lee, Jae Min; Paik, Woo Hyun

    2016-12-01

    Bilateral stent-in-stent (SIS) self-expandable metal stent placement is technically challenging for palliation of unresectable malignant hilar obstruction. In the SIS technique, the uniform large cell type biliary stent facilitates contralateral stent deployment through the mesh of the first metallic stent. This study aimed to assess the technical success and clinical effectiveness of this technique with a uniform large cell type biliary stent. Thirty-one patients who underwent bilateral SIS placement using a large cell type stent were reviewed retrospectively. All patients showed malignant hilar obstruction (Bismuth types II, III, IV) with different etiologies. Sixteen (51.6%) patients were male. The mean age of the patients was 67.0+/-14.0 years. Most patients were diagnosed as having hilar cholangiocarcinoma (58.1%) and gallbladder cancer (29.0%). Technical success rate was 83.9%. Success was achieved more frequently in patients without masses obstructing the biliary confluence (MOC) than those with MOC (95.2% vs 60.0%, P=0.03). Functional success rate was 77.4%. Complications occurred in 29.0% of the patients. These tended to occur more frequently in patients with MOC (50.0% vs 19.0%, P=0.11). Median time to recurrent biliary obstruction was 188 days and median survival was 175 days. The large cell type stent can be used efficiently for bilateral SIS placement in malignant hilar obstruction. However, the risk of technical failure increases in patients with MOC, and caution is needed to prevent complications for these patients.

  8. Angulated Stents-A Novel Stent Improvisation to Manage Difficult Post-tuberculosis Bronchial Stenosis.

    Science.gov (United States)

    Tay, Chee Kiang; Jeong, Byeong-Ho; Kim, Hojoong

    2017-10-18

    Post-tuberculosis bronchostenosis (PTBS), a complication of endobronchial tuberculosis is currently treated by bronchial stenting. However, in cases of angulated bronchial stenoses, difficulty is often encountered in stent insertion and maintenance, resulting in stent migration, granulation tissue overgrowth, and restenosis. To accommodate the angulated alignment of the stenosis, we devised an "angulated stent"-a novel improvisation of the conventional stent via splicing and suturing to achieve a resultant angulated shape. A retrospective review was undertaken to evaluate the performance of this stent. Among 283 PTBS patients who underwent interventional bronchoscopy at our center from 2004 to 2014, 21 were treated with at least one angulated stent. Clinical outcomes, including the stenting duration were investigated. After a median follow-up of 26 months, stent removal was successful in 7 (33.3%) out of 21 patients. In patients managed with angulated stents, the median duration to stent change or eventual removal was longer than those treated with straight tube stents (392 days vs. 86 days; p < 0.05). Angulated stents are a feasible treatment option in patients with angulated PTBS by reducing complications and prolonging the stent-changing interval.

  9. Removal of self expandable metallic airway stent: A rare case report

    OpenAIRE

    Chawla, Rakesh K.; Madan, Arun; Singh, Ishwar; Mudoiya, Rahul; Chawla, Aditya; Gupta, Radha; Chawla, Kiran; Chhabra, Roopam

    2013-01-01

    Covered self expandable metallic airway stents (SEMS) have been used for benign tracheal stenosis, post intubation tracheal stenosis, tracheal burn or trauma, tracheo-broncho-malacia, and extrinsic compression of trachea. Their placement is considered to be permanent, with open surgery the only way to remove the stent, though there are few cases reports of their removal with the bronchoscope, but the complications after their removal are very high. In our patient, one and a half years after p...

  10. A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.

    Science.gov (United States)

    Khashab, Mouen A; Hutfless, Susan; Kim, Katherine; Lennon, Anne Marie; Canto, Marcia I; Jagannath, Sanjay B; Okolo, Patrick I; Shin, Eun Ji; Singh, Vikesh K

    2012-06-01

    Conventional plastic stents with a lumen typically have limited patency. The lumenless wing stent was engineered to overcome this problem. The objective of this study was to compare the incidence of early stent occlusion (symptomatic occlusion/cholangitis necessitating re-insertion within 90 days) for wing stents and conventional plastic stents. Patients with biliary pathology treated with plastic biliary stenting during the period 2003-2009 comprised the study cohort. Patients who had at least one biliary wing stent placed comprised the wing stent group, whereas patients who underwent only conventional stent plastic placement comprised the conventional stent group. Patients were stratified by indication: benign biliary strictures (group 1), malignant biliary strictures (group 2), or benign biliary non-stricture pathology (group 3). The association of stent type with the occurrence of primary outcome by indication was analyzed by use of multivariable logistic regression. Three-hundred and forty-six patients underwent 612 ERCP procedures with placement of plastic biliary stent(s). On multivariate analysis, early stent occlusion did not differ between the wing and conventional groups in groups 1, 2, and 3. Among patients who achieved primary outcome in group 2, significantly fewer patients in the wing group had cholangitis (6.7% vs. 39.1%, P = 0.03). Among patients who achieved primary outcome in group 3, significantly fewer patients in the wing group had cholangitis (10% vs. 50%, P = 0.03). Early stent occlusion was similar for wing stents and conventional plastic stents. Wing stents, however, were associated with a lower incidence of cholangitis in patients with malignant biliary obstruction and benign non-stricturing biliary pathology.

  11. Hydroxyapatite-silver nanoparticles coatings on porous polyurethane scaffold

    International Nuclear Information System (INIS)

    Ciobanu, Gabriela; Ilisei, Simona; Luca, Constantin

    2014-01-01

    The present paper is focused on a study regarding the possibility of obtaining hydroxyapatite-silver nanoparticle coatings on porous polyurethane scaffold. The method applied is based on a combined strategy involving hydroxyapatite biomimetic deposition on polyurethane surface using a Supersaturated Calcification Solution (SCS), combined with silver ions reduction and in-situ crystallization processes on hydroxyapatite-polyurethane surface by sample immersing in AgNO 3 solution. The morphology, composition and phase structure of the prepared samples were characterized by scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDX), X-ray diffraction (XRD), UV-Vis spectroscopy and X-ray photoelectron spectroscopy (XPS) measurements. The data obtained show that a layer of hydroxyapatite was deposited on porous polyurethane support and the silver nanoparticles (average size 34.71 nm) were dispersed among and even on the hydroxyapatite crystals. Hydroxyapatite/polyurethane surface acts as a reducer and a stabilizing agent for silver ions. The surface plasmon resonance peak in UV-Vis absorption spectra showed an absorption maximum at 415 nm, indicating formation of silver nanoparticles. The hydroxyapatite-silver polyurethane scaffolds were tested against Staphylococcus aureus and Escherichia coli and the obtained data were indicative of good antibacterial properties of the materials. - Highlights: • The hydroxyapatite and silver nanoparticles were grown on the polyurethane scaffold • The hydroxyapatite/polyurethane acts as reducing agent, stabilizer and matrix for Ag • The samples were well characterized by SEM-EDX, XRD, XPS, UV-visible spectroscopy • The hydroxyapatite/silver polyurethane scaffold shows antibacterial property

  12. Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study

    Science.gov (United States)

    Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe

    2016-05-01

    In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.

  13. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    Science.gov (United States)

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  14. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    Science.gov (United States)

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  15. Microvascular stent anastomosis using N-fibroin stents: feasibility, ischemia time, and complications.

    Science.gov (United States)

    Smeets, Ralf; Vorwig, Oliver; Wöltje, Michael; Gaudin, Robert; Luebke, Andreas M; Beck-Broichsitter, Benedicta; Rheinnecker, Michael; Heiland, Max; Grupp, Katharina; Gröbe, Alexander; Hanken, Henning

    2016-05-01

    To evaluate a novel microvascular anastomosis technique using N-fibroin stents. Cylinder stents of 1 mm diameter and 5 mm length were fabricated using N-fibroin from silkworms. In 22 rats, aortas were dissected, and the stent was inserted into the two ends of the aorta and fixed using methylmethacrylate. Stent anastomosis was successful in 21 (96%) rats. The mean ischemia time was 7.4 minutes, significantly shorter than the 15.9 minutes in the control group with conventional sutures (P stent anastomosis cases, and marked host rejection was evident at the stent anastomosis sites. Around the stents, thrombi were frequent (52%). Our study demonstrated the basic feasibility of stent anastomosis using N-fibroin stents and reduced ischemia time. However, thrombus formation, frequent and severe abdominal infections, and heavy host rejection remain critical issues. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. One-step breast reconstruction with polyurethane-covered implants after skin-sparing mastectomy.

    Science.gov (United States)

    Rancati, Alberto; Soderini, Alejandro; Dorr, Julio; Gercovich, Gustavo; Tessari, Luciano; Gonzalez, Eduardo

    2013-12-01

    Skin-sparing mastectomy (SSM) and immediate one-step breast reconstruction with implants has become an increasingly popular, effective treatment for selected patients with breast carcinoma. However, it is associated with high complication rates. Breast augmentation with polyurethane-covered implants (PCIs) has consistently had optimal short-term and long-term results with low rates of capsular contracture. The aim of this study was to evaluate the clinical and aesthetic outcomes of immediate one-step breast reconstruction with PCI after SSM in early breast cancer patients at a single institution. We reviewed the records of 221 consecutive breast cancer patients who underwent one-stage immediate reconstruction with PCI after SSM from 1995 through 2005. Patient and tumour characteristics, type of reconstruction, postoperative complications, aesthetic results and recurrence rate were analysed. The mean age of the patients was 52±11 years (range, 30-76; standard deviation (SD), 11). The American Joint Committee on Cancer (AJCC) pathologic stages were 0 (10%), I (63.3%) and II (26.7%). Thirty-nine (17.65%; confidence interval (CI)=13.04-23.1) of the 221 patients had complications; seven had prosthesis extrusion requiring an implant (five due to skin necrosis, one due to infection and one due to late haematoma). In six of these seven cases, the procedure was indicated for local recurrence after conservative breast surgery with adjunctive radiation therapy (rescue procedure). Thirty-two (14.4%) patients had minor complications: 12 had cutaneous rash, four had malpositioned implants and 16 had inadequate implant projection. At long-term follow-up, four (1.8%) patients had developed grade IV capsular contracture associated with postoperative radiation therapy. At a median follow-up of 98 months (range, 36-156), 14 (6.3%) patients had tumour recurrence and 12.2% had distant metastasis. Nineteen patients had died of cancer, and 192 (86.8%) remained disease free. One

  17. Channel Model of Molecular Communication via Diffusion in a Vessel-like Environment Considering a Partially Covering Receiver

    OpenAIRE

    Turan, Meriç; Kuran, Mehmet Sukru; Yilmaz, H. Birkan; Demirkol, Ilker; Tugcu, Tuna

    2018-01-01

    By considering potential health problems that a fully covering receiver may cause in vessel-like environments, the implementation of a partially covering receiver is needed. To this end, distribution of hitting location of messenger molecules (MM) is analyzed within the context of molecular communication via diffusion with the aim of channel modeling. The distribution of these MMs for a fully covering receiver is analyzed in two parts: angular and radial dimensions. For the angular distributi...

  18. The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Hiroshi Fujita

    2014-12-01

    Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.

  19. Structure and Properties of Polyurethanes. Part 1,

    Science.gov (United States)

    1979-03-23

    since the solidification of varnish coatings on basis it is polyurethane usually it occurs under conditions for contact wita moisture of air. Page...containing fluorine is polyurethane. In works (44, 84-86] is given the information about synthesis 11 DOC = 79011105 PAGE and special feature/peculiarities...of the phase transformations of the series/number of the fluorine -bedrlng aliphatic ones it is polyurethane. Page 87. In particular, were investigated

  20. Evaluation of the Anti-migration Effect of Barbed Prostatic Stents: In Vitro Study in Urethra-mimicking Bovine Pericardium Phantoms

    International Nuclear Information System (INIS)

    Na, Han Kyu; Song, Ho-Young; Kim, Jin Hyoung; Nam, Deok Ho; Park, Jung-Hoon; Jeong, In Gab; Kim, Choung-Soo

    2013-01-01

    This study was designed to compare the migration rates of covered stents with eight, four, and zero barbs in urethra-mimicking bovine pericardium models. Three types of polytetrafluoroethylene-covered retrievable self-expandable prostatic stents, with eight, four, and zero barbs, were tested in bovine pericardium models, consisting of normal saline-filled acrylic containers with tubes at both ends and a replica of the human urethra. The barbs were 2 mm in length and projected 60° toward the urinary bladder. The anti-migration force (AMF) and resistance force against stent removal (RFSR) were measured by an automatic push–pull gauge system at a fixed rate (2 mm/s). Significant differences in AMF among the three stent types were detected (P < 0.001). Median AMF was far greater for eight-barbed than for four-barbed stents (11.96 vs. 7.55 N, P = 0.003). For stent removal, the difference between 4- and 8-barbed stents were not significant in median static (5.54 vs. 6.08 N, P = 0.15) or sliding (prostatic urethra, 5.32 vs. 5.59 N, P = 0.65; membranous urethra, 7.78 vs. 8.57 N, P = 0.364) RFSR. No perforations or scratched traces were observed during removal of these stents. The inclusion of eight barbs projecting 60° toward the urinary bladder were not only effective against stent migration in this model but suggests that these stents may be suitable for the treatment of prostatic urethral strictures without severely irritating the tissue. However, whether these results translate into living urethral tissue is unclear, necessitating further studies.

  1. Characterization of synthesized polyurethane/montmorillonite nanocomposites foams

    International Nuclear Information System (INIS)

    Ansari, Farahnaz; Njuguna, James; Sachse, Sophia; Kavosh, Masoud; Michalowski, S; Pielichowski, Krzysztof

    2014-01-01

    Nanophased hybrid composites based on polyurethane/montmorillonite (PU/MMT) have been fabricated. The nanocomposite which was formed by the addition of a polyol premix with 4,4'-diphenylmethane diisocyanate to obtain nanophased polyurethane foams which were then used for fabrication of nanocomposite panels has been shown to have raised strength, stiffness and thermal insulation properties. The nanophased polyurethane foam was characterized by means of scanning electron microscope (SEM), transmission electron microscope (TEM) measurements and X-ray diffraction (XRD). TEM and SEM analysis indicated that nanophased particles are dispersed homogeneously in the polyurethane matrix on the nanometer scale indicating that PU/MMT is an intercalated nanocomposite with a 2-3 nm nanolayer thickness

  2. Treatment of carotid-siphon aneurysms by using willis stent-graft: an angiographic and histopathologic study in dogs

    International Nuclear Information System (INIS)

    Zhu Yueqi; Li Minghua; Xie Jian; Tan Huaqiao; Cheng Yingsheng; Wang Jianbo

    2010-01-01

    Objective: To establish a carotid siphon aneurysm model in dogs in order to test the mechanical features of a newly-designed Willis covered stent-graft and to investigate the histological reaction of the stent-implanted vessel during a follow-up period of 12 months. Methods: Twenty-four saccular sidewall aneurysms were surgically created in twelve dogs (group A) and 12 carotid siphon aneurysms in another twelve dogs (group B). A Willis stent-graft was implanted in each aneurysm. Angiography was performed immediately after the procedure and 1, 3, 6 and 12 months after the implantation to investigate the aneurysm isolation, endoleak, stent angulation, and the patency or restenosis of the parent artery. Light and scanning electronic microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress of the stent-loaded arterial segment. Results: In group B, postoperative immediate angiography demonstrated that two aneurysms had mild endoleak and three stents became angulated. Follow-up exam 12 months after the procedure revealed that all previous endoleaks disappeared, one parent artery became occluded and three parent arteries developed mild stenosis (< 50%). In group A, occlusion of parent artery was seen in one and mild stenosis (< 50%) in 2 cases. Electronic microscopy revealed new intima formation in all stents, and all aneurysmal sacs were filled with thrombi. In group B, the endothelialization process was not completed until 12 months after the stent implantation, and a marked correlation existed between endothelial cell arrangement and the hemodynamic orientation. Conclusion: It is feasible to treat carotid-siphon aneurysm in dog with a Willis stent-graft. The complete endothelialization of the covered stent in tortuous vessel takes longer time than that in rather straight vessel. (authors)

  3. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  4. POLYURETHANE COMPOSITES AS DRUG CARRIERS:: RELEASE PATTERNS

    Directory of Open Access Journals (Sweden)

    M. V. Grigoreva

    2013-10-01

    Full Text Available Biodegradable polyurethanes attract interest of those developing composite materials for biomedical applications. One of their features is their ability to serve as carriers, or matrixes, for medicines and other bioactive compounds to produce a therapeutic effect in body through targeted and/or prolonged delivery of these compounds in the process of their controlled release from matrix. The review presents polyurethane composites as matrices for a number of drugs. The relation between structure of the composites and their degradability both in vitro and in vivo and the dependence of drug release kinetics on physicochemical properties of polyurethane matrix are highlighted. The release of drugs (cefazolin, naltrexone and piroxicam from the composites based on cross-linked polyurethanes (synthesized from laprols, Mw between 1,500 and 2,000 Da and toluylene diisocyanate demonstrated more or less the same pattern (about 10 days in vitro and three to five days in vivo. In contrast, the composites with dioxydine based on a linear polyurethanes (synthesized from oligotetramethilene glycol, Mw 1,000 Da, diphenylmethane-4,4’-diisocyanate and 1,4-butanediol retained their antimicrobial activity at least 30 days. They also showed a significantly higher breaking strength as compared to that of the composites based on cross-linked polyurethanes.

  5. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  6. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology.

    Science.gov (United States)

    Dohatcu, A; Ionita, C N; Paciorek, A; Bednarek, D R; Hoffmann, K R; Rudin, S

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification.

  7. Predictive Factors of In-Stent Restenosis in Renal Artery Stenting: A Retrospective Analysis

    International Nuclear Information System (INIS)

    Vignali, Claudio; Bargellini, Irene; Lazzereschi, Michele; Cioni, Roberto; Petruzzi, Pasquale; Caramella, Davide; Pinto, Stefania; Napoli, Vinicio; Zampa, Virna; Bartolozzi, Carlo

    2005-01-01

    Purpose. To retrospectively evaluate the role of clinical and procedural factors in predicting in-stent restenosis in patients with renovascular disease treated by renal artery stenting. Methods. From 1995 to 2002, 147 patients underwent renal artery stenting for the treatment of significant ostial atherosclerotic stenosis. Patients underwent strict clinical and color-coded duplex ultrasound follow-up. Ninety-nine patients (111 stents), with over 6 months of continuous follow-up (mean 22±12 months, range 6-60 months), were selected and classified according to the presence (group A, 30 patients, 32 lesions) or absence (group B, 69 patients, 79 lesions) of significant in-stent restenosis. A statistical analysis was performed to identify possible preprocedural and procedural predictors of restenosis considering the following data: sex, age, smoking habit, diabetes mellitus, hypertension, serum creatinine, cholesterol and triglyceride levels, renal artery stenosis grade, and stent type, length and diameter. Results. Comparing group A and B patients (χ 2 test), a statistically significant relation was demonstrated between stent diameter and length and restenosis: the risk of in-stent restenosis decreased when the stent was ≥6 mm in diameter and between 15 and 20 mm in length. This finding was confirmed by multiple logistic regression analysis. Stent diameter and length were proved to be significantly related to in-stent restenosis also when evaluating only patients treated by Palmaz stent (71 stents). Conclusion. Although it is based on a retrospective analysis, the present study confirms the importance of correct stent selection in increasing long-term patency, using stents of at least 6 mm in diameter and with a length of approximately 15-20 mm

  8. Palliative self-expandable metal stents for acute malignant colorectal obstruction: clinical outcomes and risk factors for complications.

    Science.gov (United States)

    Han, Jae Pil; Hong, Su Jin; Kim, Shin Hee; Choi, Jong Hyo; Jung, Hee Jae; Cho, Youn Hee; Ko, Bong Min; Lee, Moon Sung

    2014-08-01

    Self-expandable metal stents (SEMSs) have been used as palliative treatment or bridge to surgery for obstructions caused by colorectal cancer (CRC). We assessed the long-term outcomes of palliative SEMSs and evaluated the risk factors influencing complications. One hundred and seventy-five patients underwent SEMS placement for acute malignant colorectal obstruction. Of the 72 patients who underwent palliative treatment for primary CRC, 30 patients received chemotherapy (CT) for primary cancer (CT group) and 42 underwent best supportive treatment (BST) without CT (BST group). There was a significant difference in late migration between the CT group and the BST group (20.0% in CT group, 2.4% in BST group, p = 0.018). Response to CT influenced the rate of late obstruction (0% in disease control, 35.7% in disease progression, p = 0.014). However, late obstruction was not associated with stent properties, such as diameter or type (≤22 mm vs. >22 mm, 13.5% vs. 14.3%, p = 1.00; uncovered stent vs. covered stent, 15.5% vs. 7.1%, p = 0.675) and migration (≤22 mm vs. >22 mm, 16.2% vs. 2.9%, p = 0.108; uncovered stent vs. covered stent, 8.6% vs. 14.3%, p = 0.615) in palliative SEMS. The administration of CT increases the rate of stent migration, and disease control by CT can reduce the risk of obstruction by maintaining the luminal patency of palliative SEMSs.

  9. Novel route of synthesis for cellulose fiber-based hybrid polyurethane

    Science.gov (United States)

    Ikhwan, F. H.; Ilmiati, S.; Kurnia Adi, H.; Arumsari, R.; Chalid, M.

    2017-07-01

    Polyurethanes, obtained by the reaction of a diisocyanate compound with bifunctional or multifunctional reagent such as diols or polyols, have been studied intensively and well developed. The wide range modifier such as chemical structures and molecular weight to build polyurethanes led to designs of materials that may easily meet the functional product demand and to the extraordinary spreading of these materials in market. Properties of the obtained polymer are related to the chemical structure of polyurethane backbone. A number polyurethanes prepared from biomass-based monomers have been reported. Cellulose fiber, as a biomass material is containing abundant hydroxyl, promising material as chain extender for building hybrid polyurethanes. In previous researches, cellulose fiber was used as filler in synthesis of polyurethane composites. This paper reported a novel route of hybrid polyurethane synthesis, which a cellulose fiber was used as chain extender. The experiment performed by reacting 4,4’-Methylenebis (cyclohexyl isocyanate) (HMDI) and polyethylene glycol with variation of molecular weight to obtained pre-polyurethane, continued by adding micro fiber cellulose (MFC) with variation of type and composition in the mixture. The experiment was evaluated by NMR, FTIR, SEM and STA measurement. NMR and FTIR confirmed the reaction of the hybrid polyurethane. STA showed hybrid polyurethane has good thermal stability. SEM showed good distribution and dispersion of sorghum-based MFC.

  10. Sorption of heteropoly acids by polyurethane foam

    International Nuclear Information System (INIS)

    Dmitreinko, S.G.; Goncharova, L.V.; Runov, V.K.; Zakharov, V.N.; Aslanova, L.A.

    1997-01-01

    Sorption of oxidized and reduced forms of molybdosilicic, molybdophosphoric and molybdovanadophosphoric acids by polyurethane foam based on ethers and esters is studied. On the basis of sorption dependence on solution pH, polyurethane foam type and spectral characteristics of sorbates the suggestion has been made that in the polyurethane foam phase there are two main types of sorbent-sorbate interaction: electrostatic (ion-ion) and with hydrogen bond formation: and it is impossible to determine the contribution of every interaction

  11. Adhesion aspects of polyurethane foam sandwich panels.

    OpenAIRE

    Ng, Simon L.

    2016-01-01

    Sandwich panels, polyurethane foam sandwiched between two sheets of steel, form the walls and roofs in the construction of buildings. ArcelorMittal is a manufacturer of the steel as well as these finished panels. For this project they combined with a supplier of the polyurethane foams, Huntsman Polyurethanes, to joint-fund a research project investigating the fundamental mechanisms of adhesion, as well as the causes of failures in the product which manifests primarily in two different ways...

  12. Use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats: six cases (2005-2007).

    Science.gov (United States)

    Berent, Allyson C; Weisse, Chick; Todd, Kimberly; Rondeau, Mark P; Reiter, Alexander M

    2008-11-01

    To determine outcome associated with use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats. Retrospective case series. 3 dogs and 3 cats. All 6 animals had severe inspiratory stertor at initial examination. Two animals had no orifice present at the stenosis. Nasopharyngeal stenosis was diagnosed and stent size determined by use of computed tomography. A percutaneous transluminal angioplasty balloon premounted with a balloon-expandable metallic stent was placed over a guidewire, advanced through the stenotic lesion under fluoroscopic and rhinoscopic guidance, and dilated to restore patency. All animals had immediate resolution of clinical signs after stent placement. The procedure took a median of 38 minutes (range, 22 to 70 minutes). One animal with a stenosis located far caudally needed the tip of the stent resected because of hairball entrapment and exaggerated swallowing. Both animals without an orifice in the stenosis had tissue in-growth requiring a covered stent. All animals were reexamined 6 to 12 weeks after treatment via rhinoscopy, radiography, computed tomography, or a combination of techniques. All animals lacked signs of discomfort; 5 of 6 were breathing normally 12 to 28 months after the procedure. Transnasal balloon-expandable metallic stent placement may represent a rapid, safe, noninvasive, and effective treatment in animals with nasopharyngeal stenosis. If the stenosis is extremely caudal in the nasopharynx, serial balloon dilatation might be considered prior to stent placement. A covered stent should be considered initially if the stenosis is completely closed.

  13. Polyurethane doped with low-concentration erbium

    NARCIS (Netherlands)

    Ciobanu, C.; Stoica, E.; Cascaval, C.N.; Rosu, D.; Rosu, L.; State, M.; Emandi, A.; Nemes, I.; Petrescu, F.

    2007-01-01

    ABSTRACT: Polyurethane (PU) with lactate structures inits conformation can be used as a biological and biodegradablepolymer. Polyurethane lactate (PUL) was dopedwith small quantities of an erbium (Er3þ) complex, whichhindered the N¼N group. 2,20-Dihydroxyazobenzene wasused as a ligand for the Er3þ

  14. Thermal insulating materials consisting of polyurethane rigid foam. Production - application - properties. 2. ed.; Waermedaemmstoffe aus Polyurethan-Hartschaum. Herstellung - Anwendung - Eigenschaften

    Energy Technology Data Exchange (ETDEWEB)

    Endres, Edmund; Kleser, Joachim

    2008-02-15

    Using rigid polyurethane (PU) / polyisocyanurate (PIR) foam as a thermal insulation material enables a conservation of resources and energy conservation. Environmentally harmful emissions significantly are reduced. Under this aspect, the authors of the contribution report on the production, application, technical and physical properties of rigid polyurethane foams. Sustainable construction with rigid polyurethane foam, quality assurance and product certification are further topics of this paper.

  15. Intrasellar Iatrogenic Carotid Pseudoaneurysm: Endovascular Treatment with a Polytetrafluoroethylene-Covered S tent

    International Nuclear Information System (INIS)

    Vanninen, R. L.; Manninen, H. I.; Rinne, J.

    2003-01-01

    This case illustrates successful treatment of a large postoperative intrasellar pseudoaneurysm with a polytetrafluoroethylene (PTFE)-covered stent. The advantages and potential disadvantages of this novel method of treatment are discussed. A previously healthy 59-year-old man underwent transsphenoidal operative treatment for hypophyseal macroadenoma,complicated by bleeding. On the 17 th postoperative day the patient had profuse arterial bleeding from his nose requiring posterior tamponade. Subsequent angiography of the left internal carotid artery(ICA) revealed a large pseudoaneurysm located intrasellarly, with the orifice in the anteromedial wall in the ophthalmic segment of the ICA.Surgical treatment of the pseudoaneurysm was considered very risky. A12-mm PTFE-covered stent (JoMed, Ulestraten, Netherlands), manually compressed on a PTCA-balloon (Maxxum 4.5/13 mm, Boston Scientific,Ireland) was endovascularly delivered covering the orifice of the pseudoaneurysm. Control angiography immediately after the intervention and one year later revealed no flow into the pseudoaneurysm and the ICA was fully patent. In conclusion, deployment of a PTFE-covered stent proved to be feasible and successful in the treatment of an intrasellariatrogenic ICA pseudoaneurysm. Adequate anticoagulative treatment after the procedure is essential to prevent thrombotic complications

  16. Evaluation of the anti-migration effect of barbed prostatic stents: in vitro study in urethra-mimicking bovine pericardium phantoms.

    Science.gov (United States)

    Na, Han Kyu; Song, Ho-Young; Kim, Jin Hyoung; Nam, Deok Ho; Park, Jung-Hoon; Jeong, In Gab; Kim, Choung-Soo

    2013-02-01

    This study was designed to compare the migration rates of covered stents with eight, four, and zero barbs in urethra-mimicking bovine pericardium models. Three types of polytetrafluoroethylene-covered retrievable self-expandable prostatic stents, with eight, four, and zero barbs, were tested in bovine pericardium models, consisting of normal saline-filled acrylic containers with tubes at both ends and a replica of the human urethra. The barbs were 2 mm in length and projected 60° toward the urinary bladder. The anti-migration force (AMF) and resistance force against stent removal (RFSR) were measured by an automatic push-pull gauge system at a fixed rate (2 mm/s). Significant differences in AMF among the three stent types were detected (P barbed than for four-barbed stents (11.96 vs. 7.55 N, P = 0.003). For stent removal, the difference between 4- and 8-barbed stents were not significant in median static (5.54 vs. 6.08 N, P = 0.15) or sliding (prostatic urethra, 5.32 vs. 5.59 N, P = 0.65; membranous urethra, 7.78 vs. 8.57 N, P = 0.364) RFSR. No perforations or scratched traces were observed during removal of these stents. The inclusion of eight barbs projecting 60° toward the urinary bladder were not only effective against stent migration in this model but suggests that these stents may be suitable for the treatment of prostatic urethral strictures without severely irritating the tissue. However, whether these results translate into living urethral tissue is unclear, necessitating further studies.

  17. Evaluation of the Anti-migration Effect of Barbed Prostatic Stents: In Vitro Study in Urethra-mimicking Bovine Pericardium Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Na, Han Kyu, E-mail: hankyu1324@empas.com; Song, Ho-Young, E-mail: hysong@amc.seoul.kr; Kim, Jin Hyoung, E-mail: m1fenew@hanmail.net [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of); Nam, Deok Ho, E-mail: namjindan@paran.com [Kyung Hee University Hospital at Gangdong, School of Medicine, Kyung Hee University, Department of Radiology (Korea, Republic of); Park, Jung-Hoon, E-mail: jhparkz@amc.seoul.kr [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of); Jeong, In Gab, E-mail: uroman2000@yahoo.co.kr; Kim, Choung-Soo, E-mail: cskim@amc.seoul.kr [University of Ulsan College of Medicine, Department of Urology, Asan Medical Center (Korea, Republic of)

    2013-02-15

    This study was designed to compare the migration rates of covered stents with eight, four, and zero barbs in urethra-mimicking bovine pericardium models. Three types of polytetrafluoroethylene-covered retrievable self-expandable prostatic stents, with eight, four, and zero barbs, were tested in bovine pericardium models, consisting of normal saline-filled acrylic containers with tubes at both ends and a replica of the human urethra. The barbs were 2 mm in length and projected 60 Degree-Sign toward the urinary bladder. The anti-migration force (AMF) and resistance force against stent removal (RFSR) were measured by an automatic push-pull gauge system at a fixed rate (2 mm/s). Significant differences in AMF among the three stent types were detected (P < 0.001). Median AMF was far greater for eight-barbed than for four-barbed stents (11.96 vs. 7.55 N, P = 0.003). For stent removal, the difference between 4- and 8-barbed stents were not significant in median static (5.54 vs. 6.08 N, P = 0.15) or sliding (prostatic urethra, 5.32 vs. 5.59 N, P = 0.65; membranous urethra, 7.78 vs. 8.57 N, P = 0.364) RFSR. No perforations or scratched traces were observed during removal of these stents. The inclusion of eight barbs projecting 60 Degree-Sign toward the urinary bladder were not only effective against stent migration in this model but suggests that these stents may be suitable for the treatment of prostatic urethral strictures without severely irritating the tissue. However, whether these results translate into living urethral tissue is unclear, necessitating further studies.

  18. Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.

    Science.gov (United States)

    Yazdani, Saami K; Sheehy, Alexander; Pacetti, Stephen; Rittlemeyer, Brandon; Kolodgie, Frank D; Virmani, Renu

    2016-10-01

    Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo. © 2016, Wiley Periodicals, Inc.

  19. Characterization of adhesive of polyurethane from castor oil by FTIR, TGA and XRD

    International Nuclear Information System (INIS)

    Azevedo, Elaine C.; Santana, Simone S. de M.; Nascimento, Eduardo M. do; Claro Neto, Salvador; Lepienski, Carlos M.

    2009-01-01

    Castor oil polyurethanes are an alternative to adhesives that emanate volatile compounds. This adhesive come from a renewable source and has very low toxicity. In this work the microstructural and thermal characterization is presented. This material is partially crystalline. The mass loss start at 240 deg C and the glass transition temperature is 60 deg C. Then the adhesive is adequate to be employed at temperatures lower than 60 deg C. (author)

  20. Endovascular Management of Aorta-Iliac Stenosis and Occlusive Disease by Kissing-Stent Technique

    Directory of Open Access Journals (Sweden)

    Meng Liu

    2016-01-01

    Full Text Available Kissing-stenting treatment has been used to treat patients with peripheral artery disease (PAD. However, the long term efficacy of the stenting therapy is not well defined in Chinese PAD patients. To investigate the question, sixty-three PAD patients (37 males and 26 females, aged 66±7.3 years, were analysed in the study. They were featured as claudication (n=45, 71.4%, rest pain (n=18, 28.6%, or gangrene (n=8, 12.7%. In total, 161 stents were applied in aorta-iliac lesions with 2.6 stents for each patient, including 55 self-expanding stents, 98 balloon expandable stents, and 8 covered stents. The success rate of implanting Kissing-stents was 100%. Catheter-directed thrombolysis (CDT with urokinase was performed in 8 cases (12.7%. The severity of peripheral ischemia was significantly improved, as evidenced by 3.3-fold increase of ankle-brachial pressure index (ABI after the surgery (P=0.008. One, three, five, and seven years after surgery, the primary patency rate was 87.3%, 77.4%, 71.1%, and 65.0%, whereas the secondary patency rate was 95.2%, 92.5%, 89.5%, and 85.0%, respectively. No in-hospital mortality was recorded. In conclusion, Kissing-stenting technique for aorta-iliac lesions is safe and effective with lower complications. It is beneficial for aorta-iliac occlusions that are longer than 60 mm.

  1. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.

    Science.gov (United States)

    Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko

    2015-11-01

    The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Satisfactory arterial repair 1 year after ultrathin strut biodegradable polymer sirolimus-eluting stent implantation: an angioscopic observation.

    Science.gov (United States)

    Ishihara, Takayuki; Awata, Masaki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Uematsu, Masaaki; Mano, Toshiaki

    2018-01-15

    The ultrathin strut biodegradable polymer sirolimus-eluting stent (Orsiro, O-SES) exhibits satisfactory clinical outcomes. However, no report to date has documented the intravascular status of artery repair after O-SES implantation. We examined 5 O-SES placed in 4 patients (age 65 ± 12 years, male 75%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed immediately after percutaneous coronary intervention and 1 year later. Angioscopic images were analyzed to determine the following: (1) dominant grade of neointimal coverage (NIC) over the stent; (2) maximum yellow plaque grade; and (3) existence of thrombus. Yellow plaque grade was evaluated both immediately after stent implantation and at the time of follow-up observation. The other parameters were evaluated at the time of follow-up examination. NIC was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. Yellow plaque severity was graded as: grade 0, white; grade 1, light yellow; grade 2, yellow; and grade 3, intensive yellow. Angioscopic findings at 1 year demonstrated the following: dominant NIC grade 1, grade 2, and grade 3 in 1, 2, and 2 stents, respectively; all stents were covered to some extent; focal thrombus adhesion was observed in only 1 stent. Yellow plaque grade did not change from immediately after stent implantation to follow-up. O-SES demonstrated satisfactory arterial repair 1 year after implantation.

  3. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents--a phantom study.

    Science.gov (United States)

    Bunck, Alexander C; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R; Heindel, Walter; Maintz, David

    2012-09-01

    4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n=14) than by 2D phase contrast flow imaging (n=10). 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Palm oil based polyols for acrylated polyurethane production

    International Nuclear Information System (INIS)

    Rida Tajau; Mohd Hilmi Mahmood; Mek Zah Salleh; Khairul Zaman Mohd Dahlan; Rosley Che Ismail

    2006-01-01

    Palm oil becomes important renewable resources for the production of polyols for the polyurethane manufacturing industry. The main raw materials used for the production of acrylated polyurethane are polyols, isocyanates and hydroxyl terminated acrylate compounds. In these studies, polyurethane based natural polymer (palm oil), i.e., POBUA (Palm Oil Based Urethane Acrylate) were prepared from three different types of palm oil based polyols i.e., epoxidised palm oil (EPOP), palm oil oleic acid and refined, bleached and deodorized (RBD) palm olein based polyols. The performances of these three acrylated polyurethanes when used for coatings and adhesives were determined and compared with each other. (Author)

  5. Causes and prevention of in-stent restenosis of vertebral artery origin after stenting

    International Nuclear Information System (INIS)

    Zhao Huipin; Li Shenmao; Zhang Guangping

    2010-01-01

    Vertebral artery stenosis is an important cause of posterior circulation stroke. Vertebral artery stenosis most commonly occurs at its origin site. In recent years, balloon angioplasty and stent implantation have been widely employed in the treatment of vertebral artery origin stenosis. However, the long term outcome of stent implantation is affected by in-stent restenosis. Multiple contributory factors have been identified, but clear understanding of the overall underlying mechanism remains an enigma. With the development of pathophysiology, prevention and treatment methods of in-stent restenosis have been improved. In recent years, drug-eluting stents, radioactive stents and magnetic stents have been widely applied. To some extent, these stents and drug therapy can solve the problem of restenosis. This article aims to review the clinical application and the up-to-date research progresses in preventing and managing vertebral artery origin restenosis. (authors)

  6. Outcomes of the single-stent versus kissing-stents technique in asymmetric complex aortoiliac bifurcation lesions.

    Science.gov (United States)

    Suh, Yongsung; Ko, Young-Guk; Shin, Dong-Ho; Kim, Jung-Sun; Kim, Byeong-Keuk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo

    2015-07-01

    This study investigated the outcomes of single-stent vs kissing-stents techniques in asymmetric complex aortoiliac bifurcation (ACAB) lesions. We retrospectively investigated 80 consecutive patients (69 males, 66.6 ± 8.7 years) treated with a single stent and 30 patients (26 males, 67.1 ± 7.7 years) treated with kissing stents for ACAB between January 2005 and December 2012 from a single-center cohort. A ACAB lesion was defined as a symptomatic unilateral common iliac artery stenosis (>50%) combined with intermediate stenosis (30%-50%) in the contralateral common iliac artery ostium. The primary end point was the primary patency of the ACAB. The baseline clinical characteristics did not differ significantly between the single-stent and the kissing-stents group. Technical success was achieved in all patients. The single-stent group required fewer stents (1.3 ± 0.5 vs 2.3 ± 0.8; P stent group (3%) required bailout kissing stents because of plaque shift to the contralateral side. The major complication rates were 8% in single-stent vs 13% in the kissing-stent group, which was similar (P = .399). At 3 years, the single-stent and kissing-stents group had similar rates of primary patency (89% vs 87%; P = .916) and target lesion revascularization-free survival (93% vs 87%; P = .462). The single-stent technique in ACAB was safe and showed midterm outcomes comparable with those of kissing stents. Considering the benefits, such as fewer stents, less bilateral femoral access, and the availability of contralateral access for future intervention, the single-stent technique may be an advantageous treatment option in ACAB. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Marine biofouling resistance of polyurethane with biodegradation and hydrolyzation.

    Science.gov (United States)

    Xu, Wentao; Ma, Chunfeng; Ma, Jielin; Gan, Tiansheng; Zhang, Guangzhao

    2014-03-26

    We have prepared polyurethane with poly(ε-caprolactone) (PCL) as the segments of the main chain and poly(triisopropylsilyl acrylate) (PTIPSA) as the side chains by a combination of radical polymerization and a condensation reaction. Quartz crystal microbalance with dissipation studies show that polyurethane can degrade in the presence of enzyme and the degradation rate decreases with the PTIPSA content. Our studies also demonstrate that polyurethane is able to hydrolyze in artificial seawater and the hydrolysis rate increases as the PTIPSA content increases. Moreover, hydrolysis leads to a hydrophilic surface that is favorable to reduction of the frictional drag under dynamic conditions. Marine field tests reveal that polyurethane has good antifouling ability because polyurethane with a biodegradable PCL main chain and hydrolyzable PTIPSA side chains can form a self-renewal surface. Polyurethane was also used to carry and release a relatively environmentally friendly antifoulant, and the combined system exhibits a much higher antifouling performance even in a static marine environment.

  8. Plastic Biliary Stent Migration During Multiple Stents Placement and Successful Endoscopic Removal Using Intra-Stent Balloon Inflation Technique: A Case Report and Literature Review.

    Science.gov (United States)

    Calcara, Calcedonio; Broglia, Laura; Comi, Giovanni; Balzarini, Marco

    2016-02-05

    Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but the first stent migrated proximally at the time of second stent insertion. After failed attempts with various devices, the migrated stent was removed successfully through cannulation with a dilation balloon. The migration of a plastic biliary stent during multiple stents placement is a possible complication. In this context, extraction can be very complicated. In our patient, cannulation of a stent with a dilation balloon was the only effective method.

  9. Radiation-resistance of polyurethane pipes for cooling liquid in BES III

    International Nuclear Information System (INIS)

    Li Xunfeng; Zheng Lifang; Ji Quan; Wu Ping; Wang Li

    2009-01-01

    Gamma ray radiation and neutron radiation are predominant in the working conditions of BES III, and the radiation-resistance aging of polyurethane pipes is very important in this condition, as the pipes of cooling liquid for beam pipe and SCQ (superconducting quadrupole) vacuum pipe in BESIII. Polyester polyurethane pipes and polyether polyurethane pipes were irradiated by gamma ray and neutron. The radiation doses were as much as ten years' doses in BES. Pressure test, FTIR and thermal analysis were used to study the radiation-resistance of these two kinds of polyurethane pipes. The results show that the radiation-resistance and thermal stability of polyester polyurethane pipes are prior to those of polyether polyurethane pipes, and the pressure resistance of polyester polyurethane pipes is almost maintained after the irradiation by gamma ray and neutron, but the polyether polyurethane pipes can be aged and ruptured after the irradiation by neutron. (authors)

  10. Genous endothelial progenitor cell-capturing stent system: a novel stent technology

    NARCIS (Netherlands)

    Klomp, Margo; Beijk, Marcel A. M.; de Winter, Robbert J.

    2009-01-01

    Drug-eluting stents have been demonstrated to significantly reduce clinical and angiographic restenosis in patients with coronary artery disease compared with bare-metal stents. Intuitively, however, a prohealing approach for the prevention of in-stent restenosis by promoting accelerated

  11. Prospective Multicenter Study on the Challenges Inherent to Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction.

    Science.gov (United States)

    Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Lee, Sang Hyub; Ryu, Ji Kon; Kim, Yong-Tae; Woo, Sang Myung; Lee, Woo Jin; Jeong, Seok; Lee, Don Haeng

    2018-06-22

    Although endoscopic bilateral stent-in-stent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic reintervention. This study aimed to evaluate the technical feasibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases with technical success. Stent occlusion occurred in 63.2% of patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Large cell-type stents for endoscopic bilateral stent-in-stent placement showed acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

  12. Delayed cerebral infarction due to stent folding deformation following carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kwon Duk; Lee, Kyung Yul; Suh, Sang Hyun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established method of managing this rare complication exists, a conservative approach was taken with administration of anticoagulant and dual antiplatelet therapy. No neurological symptoms were observed during several months of clinical follow-up after discharge.

  13. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  14. Time-dependent crashworthiness of polyurethane foam

    Science.gov (United States)

    Basit, Munshi Mahbubul; Cheon, Seong Sik

    2018-05-01

    Time-dependent stress-strain relationship as well as crashworthiness of polyurethane foam was investigated under constant impact energy with different velocities, considering inertia and strain-rate effects simultaneously during the impact testing. Even though the impact energies were same, the percentage in increase in densification strain due to higher impact velocities was found, which yielded the wider plateau region, i.e. growth in crashworthiness. This phenomenon is analyzed by the microstructure of polyurethane foam obtained from scanning electron microscopy. The equations, coupled with the Sherwood-Frost model and the impulse-momentum theory, were employed to build the constitutive equation of the polyurethane foam and calculate energy absorption capacity of the foam. The nominal stress-strain curves obtained from the constitutive equation were compared with results from impact tests and were found to be in good agreement. This study is dedicated to guiding designer use polyurethane foam in crashworthiness structures such as an automotive bumper system by providing crashworthiness data, determining the crush mode, and addressing a mathematical model of the crashworthiness.

  15. Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, Claus Christian, E-mail: Claus.christian.pieper@ukb.uni-bonn.de; Meyer, Carsten, E-mail: Carsten.Meyer@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany); Rudolph, Jens, E-mail: jens.rudolph@ukb.uni-bonn.de; Verrel, Frauke, E-mail: frauke.verrel@ukb.uni-bonn.de [University of Bonn, Department of Surgery (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de; Wilhelm, Kai E., E-mail: kai.wilhelm@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany)

    2013-08-01

    PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.

  16. Stent insertion in patients with malignant biliary obstruction: problems of the Hanaro stent

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jae Hyun; Seong, Chang Kyu; Shin, Tae Beom; Kim, Yong Joo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of); Jung, Gyoo Sik [School of Medicine, Kosin National Univ., Pusan (Korea, Republic of); Park, Byeung Ho [School of Medicine, Donga National Univ., Pusan (Korea, Republic of)

    2002-07-01

    To investigate the problems of the Hanaro stent (Solco Intermed, Seoul, Korea) when used in the palliative treatment of patients with inoperable malignant biliary obstruction. Between January 2000 and May 2001, the treatment of 46 patients with malignant biliary obstruction involved percutaneous placement of the Hanaro stent. Five patients encountered problems during removal of the stent's introduction system. The causes of obstruction were pancreatic carcinoma (n=2), cholangiocarcinoma (n=2), and gastric carcinoma with biliary invasion (n=1). In one patient, percutaneous transhepatic cholangiography and stent insertion were performed as a one-step procedure, while the others underwent conventional percutaneous transhepatic biliary drainage for at least two days prior to stent insertion. A self-expandable Hanaro stent, 8-10 mm in deameter and 50-100 mm in lengh, and made from a strand of nitinol wire, was used in all cases. Among the five patients who encountered problems, breakage of the olive tip occourred in three, upward displacement of the stent in two, and improper expansion of the distal portion of the stent, unrelated with the obstruction site, in one. The broken olive tip was pushed to the duodenum in two cases and to the peripheral intrahepatic duct in one. Where the stent migrated during withdrawal of its introduction system, an additional stent was inserted. In one case, the migrated stent was positioned near the liver capsule and the drainage catheter could not be removed. Although the number of patients in this study was limited, some difficulties were encountered in withdrawing the stent's introduction system. To prevent the occurrence of this unusual complication, the stent should be appropriately expansile, and shape in the olive tip should be considered.

  17. Polyurethane-Foam Maskant

    Science.gov (United States)

    Bodemeijer, R.

    1985-01-01

    Brown wax previously used to mask hardware replaced with polyurethane foam in electroplating and electroforming operations. Foam easier to apply and remove than wax and does not contaminate electrolytes.

  18. Risk Factors and Clinical Evaluation of Superficial Femoral Artery Stent Fracture: Prote'ge'GPS Stent

    International Nuclear Information System (INIS)

    Lee, Da Un; Kim, Jae Kyu; Jung, Hye Doo; Huh, Tae Wook; Yim, Nam Yeol; Oh, Hyun jun; Choi, Soo Jin Na; Chang, Nam Kyu

    2010-01-01

    To evaluate the occurrence of superficial femoral artery stent fractures, the risk factors of stent fracture, and the relationship between fractures and clinical findings. Of the 38 patients who underwent treatment with Prote'ge'GPS stenting due to arterial occlusions on the superficial femoral artery, 17 also underwent a clinical analysis. Forty-three stents were inserted in the 17 superficial femoral arteries, ranging between 15 and 50 cm in length, with a mean treated length of 26.4 cm (15-50 cm). A fracture was evaluated by taking a PA and lateral simple radiography, as well as a follow-up evaluation accompanied with a CT angiography, DSA, and a color Doppler sonography. The examination involved the assessment of the difference between bone fractures due to length, placement, and frequency. Fractures occurred in 13 of 43 stents (30.2%). A total of 10 (71.4%) occurred in the upper third, compared to 4 (28.6%) in the lower third of the superficial femoral artery. In addition, 10 stents (71.4%) had a single strut fracture, whereas 4 (28.6%) had multiple strut fractures. A stent fracture occurred more frequently when the stents and lesions were longer (p=0.021, 0.012) and the stents were inserted near the joint. However, there was no significant relationship between stent numbers and the fractures (p=0.126). When the stents were inserted along the popliteal artery, a stent fracture occurred more frequently in the lower third of the artery. The stent fractures did not significantly influence the patency rate of the stented artery (p=0.44) Prote'ge'GPS stents in the superficial femoral artery revealed a considerable number of fractures and the fracture frequency showed a significant relationship with the length of stents and lesions. The closer stent insertion was to the joints, the more frequently fractures occurred. There were no evident significant relationships between the presence of stent fractures and the patency of the stented arteries

  19. Corrosion Prevention of Aluminum Nanoparticles by a Polyurethane Coating.

    Science.gov (United States)

    Nishimura, Toshiyasu; Raman, Vedarajan

    2014-06-19

    In order to prevent corrosion, aluminum nanoparticles were coated with a polyurethane polymer. The coverage of the polyurethane polymer was controlled from 0 to 100%, which changed the corrosion rate of the nanoparticles quantitatively. The surface of the polymer coating was investigated by Transmission Electron Microscopy (TEM) and Atomic Force Microscopy (AFM), and the corrosion resistance of the nanoparticles was estimated by a wet/dry corrosion test on a Pt plate with a NaCl solution. From a TEM with EDAX analysis, the 10 mass% polymer coated Al particles in the synthesis were almost 100% covered on the surface by a polymer film of 10 nm thick. On the other hand, the 3 mass% polymer coated Al was almost 40% covered by a film. In the AFM, the potential around the Al particles had a relatively low value with the polymer coating, which indicated that the conductivity of the Al was isolated from the Pt plate by the polymer. Both the corrosion and H₂ evolution reaction rates were quantitatively reduced by the mass% of polymer coating. In the case of the 10 mass% coated sample, there was no corrosion of Al nanoparticles. This fact suggested that the electrochemical reaction was suppressed by the polymer coating. Moreover, the reaction rate of Al nanoparticles was suppressed in proportion to the coverage percentage of the coating. Thus, to conclude, it was found that the corrosion rate of Al nanoparticles could be quantitatively suppressed by the coverage percentage of the polymer coating.

  20. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents – A phantom study

    International Nuclear Information System (INIS)

    Bunck, Alexander C.; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C.; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R.

    2012-01-01

    Purpose: 4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. Materials and methods: 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. Results: In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n = 14) than by 2D phase contrast flow imaging (n = 10). Conclusions: 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type

  1. Endovascular implantation of stent-grafts in the thoracic aorta - mid-term results of a prospective controlled study

    International Nuclear Information System (INIS)

    Duda, S.H.; Pusich, B.; Tepe, G.; Pereira, P.; Feuls, R.; Claussen, C.D.; Raygrotzki, S.; Aebert, H.; Ziemer, G.; Uckmann, F.P.

    2002-01-01

    Purpose: To evaluate the effectiveness and safety of endovascular treatment of various descending thoracic aortic pathologies with covered stent-grafts as an alternative to open surgery. Methods: Among 16 patients (5 type B dissections, 5 contained ruptures, 3 aneurysms of the descending aorta, 1 thoraco-abdominal aneurysm, 1 mural thrombosis, 1 patch aneurysm) treated between November 1997 and November 2000, eight patients received Talent TM stent-grafts and another 8 patients underwent a Gore-TAG TM stent-graft implantation. A clinical follow-up and control CT scans were obtained after the procedure and then at six-month intervals. Results: Deployment of the stent-grafts was technically successful in all cases. Sufficient aortic reconstruction was achieved in all but one patient who needed surgical treatment. One patient died two days after the procedure from aortic rupture due to retrograde type A dissection. Another patient died 19 months after the procedure from an unknown cause. There was no occurrence of distal embolization, paralysis or infection. During follow-up, all patients remained free from recurrence or late complications of their disease. Conclusion: Endoluminal treatment of thoracic aortic pathologies with covered stent-grafts appears to be a safe and feasible method with at least mid-term efficacy. (orig.) [de

  2. Hydroxyapatite-silver nanoparticles coatings on porous polyurethane scaffold.

    Science.gov (United States)

    Ciobanu, Gabriela; Ilisei, Simona; Luca, Constantin

    2014-02-01

    The present paper is focused on a study regarding the possibility of obtaining hydroxyapatite-silver nanoparticle coatings on porous polyurethane scaffold. The method applied is based on a combined strategy involving hydroxyapatite biomimetic deposition on polyurethane surface using a Supersaturated Calcification Solution (SCS), combined with silver ions reduction and in-situ crystallization processes on hydroxyapatite-polyurethane surface by sample immersing in AgNO3 solution. The morphology, composition and phase structure of the prepared samples were characterized by scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDX), X-ray diffraction (XRD), UV-Vis spectroscopy and X-ray photoelectron spectroscopy (XPS) measurements. The data obtained show that a layer of hydroxyapatite was deposited on porous polyurethane support and the silver nanoparticles (average size 34.71 nm) were dispersed among and even on the hydroxyapatite crystals. Hydroxyapatite/polyurethane surface acts as a reducer and a stabilizing agent for silver ions. The surface plasmon resonance peak in UV-Vis absorption spectra showed an absorption maximum at 415 nm, indicating formation of silver nanoparticles. The hydroxyapatite-silver polyurethane scaffolds were tested against Staphylococcus aureus and Escherichia coli and the obtained data were indicative of good antibacterial properties of the materials. © 2013.

  3. The Modification of Polyurethane Foams Using New Boroorganic Polyols (II) Polyurethane Foams from Boron-Modified Hydroxypropyl Urea Derivatives

    Science.gov (United States)

    2014-01-01

    The work focuses on research related to determination of application possibility of new, ecofriendly boroorganic polyols in rigid polyurethane foams production. Polyols were obtained from hydroxypropyl urea derivatives esterified with boric acid and propylene carbonate. The influence of esterification type on properties of polyols and next on polyurethane foams properties was determined. Nitrogen and boron impacts on the foams' properties were discussed, for instance, on their physical, mechanical, and electric properties. Boron presence causes improvement of dimensional stability and thermal stability of polyurethane foams. They can be applied even at temperature 150°C. Unfortunately, introducing boron in polyurethanes foams affects deterioration of their water absorption, which increases as compared to the foams that do not contain boron. However, presence of both boron and nitrogen determines the decrease of the foams combustibility. Main impact on the decrease combustibility of the obtained foams has nitrogen presence, but in case of proper boron and nitrogen ratio their synergic activity on the combustibility decrease can be easily seen. PMID:24587721

  4. Evaluating the interaction of a tracheobronchial stent in an ovine in-vivo model.

    Science.gov (United States)

    McGrath, Donnacha J; Thiebes, Anja Lena; Cornelissen, Christian G; O'Brien, Barry; Jockenhoevel, Stefan; Bruzzi, Mark; McHugh, Peter E

    2018-04-01

    Tracheobronchial stents are used to restore patency to stenosed airways. However, these devices are associated with many complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. Of these, granulation tissue formation is the complication that most frequently requires costly secondary interventions. In this study a biomechanical lung modelling framework recently developed by the authors to capture the lung in-vivo stress state under physiological loading is employed in conjunction with ovine pre-clinical stenting results and device experimental data to evaluate the effect of stent interaction on granulation tissue formation. Stenting is simulated using a validated model of a prototype covered laser-cut tracheobronchial stent in a semi-specific biomechanical lung model, and physiological loading is performed. Two computational methods are then used to predict possible granulation tissue formation: the standard method which utilises the increase in maximum principal stress change, and a newly proposed method which compares the change in contact pressure over a respiratory cycle. These computational predictions of granulation tissue formation are then compared to pre-clinical stenting observations after a 6-week implantation period. Experimental results of the pre-clinical stent implantation showed signs of granulation tissue formation both proximally and distally, with a greater proximal reaction. The standard method failed to show a correlation with the experimental results. However, the contact change method showed an apparent correlation with granulation tissue formation. These results suggest that this new method could be used as a tool to improve future device designs.

  5. Synthesis and characterization of nanocomposites based on polyurethane in aqueous dispersions with non-modified hydrophilic clays

    International Nuclear Information System (INIS)

    Miranda, G.S.; Delpechi, M.C.; Santo, W.L.E.

    2010-01-01

    Several studies involving the formation of polyurethane nanocomposites employing clays of montmorillonite modified. This involves the presence of quaternary ammonium salts, the cation exchange needed to increase the interlayer space of clays that incorporate more than one step to the process, generates a higher cost. In this paper the synthesis of nanocomposite polyurethanes dispersed in water allowed not only the production of materials less harmful to the environment, but also the incorporation of hydrophilic clays, calcium and sodium in nature, without any modifications. Dispersions produced from 0.5, 1.0 and 2.5% clay (on the mass of prepolymer) were characterized in terms of total solids content, the films obtained by casting were evaluated for adhesiveness, diffraction X-rays, scanning electron microscopy. Most systems showed intercalated and partially exfoliated structures. (author)

  6. Polyurethane-Coated Breast Implants Revisited: A 30-Year Follow-Up

    Directory of Open Access Journals (Sweden)

    Nikki Castel

    2015-03-01

    Full Text Available BackgroundPolyurethane coating of breast implants has been shown to reduce capsular contracture in short-term follow-up studies. This 30-year study is the longest examination of the use of polyurethane-coated implants and their correlation with capsular contracture.MethodsThis study evaluates the senior surgeon's (F.D.P. experience with the use of polyurethane-coated implants in aesthetic breast augmentation in 382 patients over 30 years. Follow-up evaluations were conducted for six months after surgery. After the six-month follow-up period, 76 patients returned for reoperation. The gross findings, histology, and associated capsular contracture were noted at the time of explantation.ResultsNo patient during the six-month follow-up period demonstrated capsular contracture. For those who underwent reoperation for capsular contracture, Baker II/III contractures were noted nine to 10 years after surgery and Baker IV contractures were noted 12 to 21 years after surgery. None of the explanted implants had macroscopic evidence of polyurethane, which was only found during the first five years after surgery. The microscopic presence of polyurethane was noted in all capsules up to 30 years after the original operation.ConclusionsAn inverse correlation was found between the amount of polyurethane coating on the implant and the occurrence of capsular contracture. Increasingly severe capsular contracture was associated with a decreased amount of polyurethane coating on the surface of the implants. No contracture occurred in patients whose implants showed incomplete biodegradation of polyurethane, as indicated by the visible presence of polyurethane coating. We recommend research to find a non-toxic, non-biodegradable synthetic material as an alternative to polyurethane.

  7. Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex.

    Science.gov (United States)

    Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J

    2017-07-01

    We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.

  8. Hydrophilic polyurethane matrix promotes chondrogenesis of mesenchymal stem cells☆

    Science.gov (United States)

    Nalluri, Sandeep M.; Krishnan, G. Rajesh; Cheah, Calvin; Arzumand, Ayesha; Yuan, Yuan; Richardson, Caley A.; Yang, Shuying; Sarkar, Debanjan

    2016-01-01

    Segmental polyurethanes exhibit biphasic morphology and can control cell fate by providing distinct matrix guided signals to increase the chondrogenic potential of mesenchymal stem cells (MSCs). Polyethylene glycol (PEG) based hydrophilic polyurethanes can deliver differential signals to MSCs through their matrix phases where hard segments are cell-interactive domains and PEG based soft segments are minimally interactive with cells. These coordinated communications can modulate cell–matrix interactions to control cell shape and size for chondrogenesis. Biphasic character and hydrophilicity of polyurethanes with gel like architecture provide a synthetic matrix conducive for chondrogenesis of MSCs, as evidenced by deposition of cartilage-associated extracellular matrix. Compared to monophasic hydrogels, presence of cell interactive domains in hydrophilic polyurethanes gels can balance cell–cell and cell–matrix interactions. These results demonstrate the correlation between lineage commitment and the changes in cell shape, cell–matrix interaction, and cell–cell adhesion during chondrogenic differentiation which is regulated by polyurethane phase morphology, and thus, represent hydrophilic polyurethanes as promising synthetic matrices for cartilage regeneration. PMID:26046282

  9. Hydrophilic polyurethane matrix promotes chondrogenesis of mesenchymal stem cells.

    Science.gov (United States)

    Nalluri, Sandeep M; Krishnan, G Rajesh; Cheah, Calvin; Arzumand, Ayesha; Yuan, Yuan; Richardson, Caley A; Yang, Shuying; Sarkar, Debanjan

    2015-09-01

    Segmental polyurethanes exhibit biphasic morphology and can control cell fate by providing distinct matrix guided signals to increase the chondrogenic potential of mesenchymal stem cells (MSCs). Polyethylene glycol (PEG) based hydrophilic polyurethanes can deliver differential signals to MSCs through their matrix phases where hard segments are cell-interactive domains and PEG based soft segments are minimally interactive with cells. These coordinated communications can modulate cell-matrix interactions to control cell shape and size for chondrogenesis. Biphasic character and hydrophilicity of polyurethanes with gel like architecture provide a synthetic matrix conducive for chondrogenesis of MSCs, as evidenced by deposition of cartilage-associated extracellular matrix. Compared to monophasic hydrogels, presence of cell interactive domains in hydrophilic polyurethanes gels can balance cell-cell and cell-matrix interactions. These results demonstrate the correlation between lineage commitment and the changes in cell shape, cell-matrix interaction, and cell-cell adhesion during chondrogenic differentiation which is regulated by polyurethane phase morphology, and thus, represent hydrophilic polyurethanes as promising synthetic matrices for cartilage regeneration. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.

    Science.gov (United States)

    Kim, Jung-Sun; Ha, Jinyong; Kim, Byeong-Keuk; Shin, Dong-Ho; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2014-06-01

    This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. Tracking the fate of interested regions of struts at different time points has not been investigated. Post-intervention and 6-month follow-up optical coherence tomographic evaluations were performed in 82 patients treated with biolimus- (n = 37) or sirolimus-eluting stents (n = 45). Post-stent apposition was classified as embedded, apposed, or malapposed. For volumetric stent evaluation, the post-intervention strut-artery distance and the neointimal thickness at follow-up were measured as a function of the circumferential arc length and longitudinal stent length. Computer-generated contour plots of the strut-artery distance and neointimal thickness were compared. The percentages of embedded and malapposed struts after intervention were 1.8% (Interquartile range [IQR]: 0.6% to 6.2%) and 2.3% (IQR: 0.5% to 5.2%), respectively. The percentages of uncovered and malapposed struts at 6 months were 16.0% (IQR: 7.4% to 33.3%) and 0% (IQR: 0% to 0.7%), respectively. The percentage of uncovered struts at 6 months varied significantly with post-stent strut apposition (0% [IQR: 0% to 11.4%] in embedded, 16.3% [IQR: 8.1% to 31.3%] in apposed, and 26.8% [IQR: 0% to 56.3%] in malapposed, p < 0.001 for all pairwise comparisons). In lesions without tissue prolapse, embedded struts were all covered (100% covered struts) compared with those with tissue prolapse (76.8% covered, p < 0.001). The optical coherence tomography-guided optimization of stent strut apposition enhances strut coverage at follow-up. This comprehensive method for evaluating strut apposition may provide more useful information to understanding the serial changes in strut coverage. (Neointimal Coverage After Implantation of Biolimus Eluting Stent With Biodegradable Polymer: Optical Coherence Tomographic Assessment According to the Treatment of

  11. Stent-assisted mechanical recanalization for the treatment of acute ischemic stroke

    International Nuclear Information System (INIS)

    Xu Haowen; Song Bo; Guo Xinbin; Guan Sheng

    2011-01-01

    Objective: to evaluate the safety and efficacy of stent-assisted mechanical recanalization technique in treating acute ischemic stroke. Methods: Stent-assisted mechanical recanalization procedure was carried out in 12 patients with acute ischemic stroke. The lesions were located at the anterior circulation in 10 cases and at posterior circulation in 2 cases. The clinical data were retrospectively analyzed. The technical success rate, the vascular recanalization, the occurrence of symptomatic intracranial hemorrhage, the clinical improvement and mortality were observed and evaluated. Results: The stent was successfully deployed in 11 patients (92%). After the treatment, different degrees of vascular recanalization were obtained in all patients. The complete (TIMI 3), partial (TIMI 2) and minor (TIMI 1) recanalization rate was 58.3% (7/12), 25% (3/12) and 8.3% (1/12), respectively. Postoperative symptomatic intracranial hemorrhage occurred in one patient (8.3%). Stroke-related death occurred in one patient (8.3%) and eight patients had their modified Rankin Score ≤ 2. Conclusion: For the treatment of acute ischemic stroke, stent-assisted mechanical recanalization technique is clinically feasible and safe with high vascular recanalization rate although further studies with larger sample to clarify its clinical usefulness are still needed. (authors)

  12. An experimental study on the influence of new spiral stent(Hanaro) on the vascular structures

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Chung, Jin Wook; Jeong, Yoong Ki; Kook, Myeong Cherl; Seo, Jung Wook [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of); Lim, Myung Kwan [Inha Univ. College of Medicine, Incheon (Korea, Republic of)

    1996-06-01

    The purpose of this study was to evaluate basic experimental data for the clinical application of a self-expandable stainless steel intravascular Hanaro spiral stent. For evaluation of the physical properties of the Hanaro stent, hoop strength, radioopacity, longitudinal flexibility, and foreshortening were measured. Twelve intravascular hanaro spiral stents were placed in the infrarenal abdominal aorta (n=6) and common iliac artery (n=6) in six mongrel dogs. Angiography and light microscopic examination were performed after one, two and eight months of placement of the stents. The stent had good radioopacity and was deployed with minimal foreshortening. hoop strength of a 6 mm-interval bend was found to be superior to that of 8 mm- and 10 mm-bend stent. On angiography the patency rate and thrombosis rate were 100% and 0% in the abdominal aorta and 50% in the common iliac artery, respectively. Minimal corrosion was seen in all stents, and they appeared to be biocompatible. The stent wires were covered with well-developed neointima which after one month had mostly fibroblast and collagen tissue ; the thickness of the neointima increased gradually during a period of eight months. At the end of that period, collagen fibres in the neointima were denser and showed a more paralled configuration than at one month. The Hanaro stent has good physical properties and also has a high patency rate, and good biocompatibilities. The stent may therefore be reliably and safely deployed in the human vascular system.

  13. Biodegradative Activities of Selected Environmental Fungi on a Polyester Polyurethane Varnish and Polyether Polyurethane Foams.

    Science.gov (United States)

    Álvarez-Barragán, Joyce; Domínguez-Malfavón, Lilianha; Vargas-Suárez, Martín; González-Hernández, Ricardo; Aguilar-Osorio, Guillermo; Loza-Tavera, Herminia

    2016-09-01

    Polyurethane (PU) is widely used in many aspects of modern life because of its versatility and resistance. However, PU waste disposal generates large problems, since it is slowly degraded, there are limited recycling processes, and its destruction may generate toxic compounds. In this work, we isolated fungal strains able to grow in mineral medium with a polyester PU (PS-PU; Impranil DLN) or a polyether PU (PE-PU; Poly Lack) varnish as the only carbon source. Of the eight best Impranil-degrading strains, the six best degraders belonged to the Cladosporium cladosporioides complex, including the species C. pseudocladosporioides, C. tenuissimum, C. asperulatum, and C. montecillanum, and the two others were identified as Aspergillus fumigatus and Penicillium chrysogenum The best Impranil degrader, C. pseudocladosporioides strain T1.PL.1, degraded up to 87% after 14 days of incubation. Fourier transform infrared (FTIR) spectroscopy analysis of Impranil degradation by this strain showed a loss of carbonyl groups (1,729 cm(-1)) and N-H bonds (1,540 and 1,261 cm(-1)), and gas chromatography-mass spectrometry (GC-MS) analysis showed a decrease in ester compounds and increase in alcohols and hexane diisocyanate, indicating the hydrolysis of ester and urethane bonds. Extracellular esterase and low urease, but not protease activities were detected at 7 and 14 days of culture in Impranil. The best eight Impranil-degrading fungi were also able to degrade solid foams of the highly recalcitrant PE-PU type to different extents, with the highest levels generating up to 65% of dry-weight losses not previously reported. Scanning electron microscopy (SEM) analysis of fungus-treated foams showed melted and thinner cell wall structures than the non-fungus-treated ones, demonstrating fungal biodegradative action on PE-PU. Polyurethane waste disposal has become a serious problem. In this work, fungal strains able to efficiently degrade different types of polyurethanes are reported, and

  14. Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.

    Science.gov (United States)

    Simsekyilmaz, Sakine; Liehn, Elisa A; Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T A; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma

    2016-01-01

    Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.

  15. Self-expandable metallic stents vs. plastic stents for endoscopic biliary drainage in hepatocellular carcinoma.

    Science.gov (United States)

    Chung, Kwang Hyun; Lee, Sang Hyub; Park, Jin Myung; Lee, Jae Min; Ahn, Dong-Won; Ryu, Ji Kon; Kim, Yong-Tae

    2015-06-01

    The patency of self-expandable metallic stents (SEMS) is known to be better than plastic stents in the palliation of malignant biliary obstruction. However, data are scarce for obstructive jaundice caused by hepatocellular carcinoma (HCC). This study aimed to compare SEMSs and plastic stents for the palliation of obstructive jaundice in unresectable HCC. A total of 96 patients who underwent endoscopic retrograde biliary drainage with SEMSs or plastic stents were included in this retrospective analysis. The rate of successful biliary drainage, adverse events, stent patency duration, and patient survival were compared between the SEMS (n = 36) and plastic stent (n = 60) groups. The rate of successful biliary drainage was similar between the SEMS and plastic stent groups (25/36 [69.4 %] vs. 39/60 [65.0 %]; P = 0.655). Adverse events occurred in 6 patients (16.7 %) in the SEMS group and 13 patients (21.7 %) in the plastic stent group (P = 0.552). The median patency duration was also similar between the two groups (60 vs. 68 days; P = 0.396). The median patient survival was longer in the plastic stent group than in the SEMS group (123 vs. 48 days; P = 0.005). SEMSs were not superior to plastic stents for the palliation of malignant biliary obstruction in HCC with regard to successful drainage, stent patency, and adverse events. Patient survival was better in the plastic stent group. Given the lower cost, plastic stents could be a favorable option for malignant biliary obstruction caused by HCC. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Rigid Polyurethane Foam Reinforced Coconut Coir Fiber Properties

    OpenAIRE

    Mohd Azham Azmi

    2012-01-01

    This research work studied the properties of composite foam panels. Coconut coir fibers were used as reinforcement in polyurethane (PU) foam in order to increase the properties of foam. This composite foam panels were fabricated by using polyurethane molded method. The polyurethane foam panels reinforced from 5 to 20wt% coconut coir were produced to investigate the physical and mechanical test via density test and three point bending test respectively. It was found that the density test resul...

  17. Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective.

    Science.gov (United States)

    Bashar, Abul Hasan Muhammad; Kazui, Teruhisa; Washiyama, Naoki; Terada, Hitoshi; Yamashita, Katsushi; Haque, Mohammad E

    2003-08-01

    To comparatively assess the mechani-cal behavior of various clinically relevant Z-stent designs. A total of 16 Z-stents of original, biliary, spiral, and double-skirted designs (n=4 for each) were constructed using similar specifications for all. Stents were then evaluated for stiffness, snap opening force (SOF), flexibility, and displacement force using a novel tensiometer. Differences among the stents were determined using statistical methods. Stents explanted from dog aorta after a mean follow-up of 13 months were examined under a scanning electron microscope for surface defects. Forces required for about 50% reduction in diameter were 1.88 +/- 0.16 N, 3.81 +/- 0.21 N, 2.76 +/- 0.22 N, and 3.35 +/- 0.19 N for original, biliary, spiral, and skirted designs, respectively. Differences among the four designs were statistically significant at almost all points of measurement (P designs showed higher SOF values in the early measurements. Stents explanted from dog aorta after a mean duration of 13 months showed no obvious corrosion or breakage in the wire struts. Significant differences exist among the various Z-stent designs in terms of their mechanical properties. Understanding them should help to select the appropriate stent for a given lesion. 316L stainless steel shows a favorable long-term tissue interaction.

  18. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

    Science.gov (United States)

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Stettler, Christoph; Sangiorgi, Diego; D'Ascenzo, Fabrizio; Kimura, Takeshi; Briguori, Carlo; Sabatè, Manel; Kim, Hyo-Soo; De Waha, Antoinette; Kedhi, Elvin; Smits, Pieter C; Kaiser, Christoph; Sardella, Gennaro; Marullo, Antonino; Kirtane, Ajay J; Leon, Martin B; Stone, Gregg W

    2012-04-14

    The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare

  19. Treatment of Post-Stent Gastroesophageal Reflux by Anti-Reflux Z-Stent

    International Nuclear Information System (INIS)

    Davies, Roger Philip; Kew, Jacqueline; Byrne, Peter D.

    2000-01-01

    Severe symptoms of heartburn and retrosternal pain consistent with gastro-esophageal reflux (GER) developed in a patient following placement of a conventional self-expanding 16-24-mm-diameter x 12-cm-long esophageal stent across the gastroesophageal junction to treat an obstructing esophageal carcinoma. A second 18-mm-diameter x 10-cm-long esophageal stent with anti-reflux valve was deployed coaxially and reduced symptomatic GER immediately. Improvement was sustained at 4-month follow-up. An anti-reflux stent can be successfully used to treat significant symptomatic GER after conventional stenting

  20. Radiation-induced changes affecting polyester based polyurethane binder

    Science.gov (United States)

    Pierpoint, Sujita Basi

    The application of thermoplastic polyurethane elastomers as binders in the high energy explosives particularly when used in weapons presents a significantly complex and challenging problem due to the impact of the aging of this polymer on the useful service life of the explosive. In this work, the effects of radiation on the aging of the polyester based polyurethane were investigated using both electron beam and gamma irradiation at various dose rates in the presence and absence of oxygen. It was found by means of GPC that, in the presence and absence of oxygen, the poly (ester urethane) primarily undergoes cross-linking, by means of a carbon-centered secondary alkyl radical. It was also concluded that the polymer partially undergoes scission of the backbone of the main chain at C-O, N-C, and C-C bonds. Substantial changes in the conditions of irradiation and in dose levels did not affect the cross-linking and scission yields. Experiments were also performed with EPR spectroscopy for the purpose of identifying the initial carbon-centered free radicals and for studying the decay mechanisms of these radicals. It was found that the carbon-centered radical which is produced via C-C scission (primary alkyl radical) is rapidly converted to a long-lived allylic species at higher temperatures; more than 80% radicals are converted to allyl species in 2.5 hours. In the presence of oxygen, the allyl radical undergoes a fast reaction to produce a peroxyl radical; this radical decays with a 1.7 hour half-life by pseudo first-order kinetics to negligible levels in 13 hours. FTIR measurements were conducted to identify the radiation-induced changes to the functional groups in the polyester polyurethane. These measurements show an increase in carbonyl, amine and carboxylic groups as a result of reaction of H atoms with R-C-O·, ·NH-R and R-COO·. The FTIR results also demonstrate the production of the unsaturation resulting from hydrogen atom transfer during intrachain conversion

  1. Impact of stent strut design in metallic stents and biodegradable scaffolds.

    Science.gov (United States)

    Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip

    2014-12-20

    Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Formulation, Preparation, and Characterization of Polyurethane Foams

    Science.gov (United States)

    Pinto, Moises L.

    2010-01-01

    Preparation of laboratory-scale polyurethane foams is described with formulations that are easy to implement in experiments for undergraduate students. Particular attention is given to formulation aspects that are based on the main chemical reactions occurring in polyurethane production. This allows students to develop alternative formulations to…

  3. Effect of silica nanoparticles on polyurethane foaming process and foam properties

    International Nuclear Information System (INIS)

    Francés, A B; Bañón, M V Navarro

    2014-01-01

    Flexible polyurethane foams (FPUF) are commonly used as cushioning material in upholstered products made on several industrial sectors: furniture, automotive seating, bedding, etc. Polyurethane is a high molecular weight polymer based on the reaction between a hydroxyl group (polyol) and isocyanate. The density, flowability, compressive, tensile or shearing strength, the thermal and dimensional stability, combustibility, and other properties can be adjusted by the addition of several additives. Nanomaterials offer a wide range of possibilities to obtain nanocomposites with specific properties. The combination of FPUF with silica nanoparticles could develop nanocomposite materials with unique properties: improved mechanical and thermal properties, gas permeability, and fire retardancy. However, as silica particles are at least partially surface-terminated with Si-OH groups, it was suspected that the silica could interfere in the reaction of poyurethane formation.The objective of this study was to investigate the enhancement of thermal and mechanical properties of FPUF by the incorporation of different types of silica and determining the influence thereof during the foaming process. Flexible polyurethane foams with different loading mass fraction of silica nanoparticles (0-1% wt) and different types of silica (non treated and modified silica) were synthesized. PU/SiO 2 nanocomposites were characterized by FTIR spectroscopy, TGA, and measurements of apparent density, resilience and determination of compression set. Addition of silica nanoparticles influences negatively in the density and compression set of the foams. However, resilience and thermal stability of the foams are improved. Silica nanoparticles do not affect to the chemical structure of the foams although they interfere in the blowing reaction

  4. Plastic vs. Self-Expandable Metal Stents for Palliation in Malignant Biliary Obstruction: A Series of Meta-Analyses.

    Science.gov (United States)

    Almadi, Majid A; Barkun, Alan; Martel, Myriam

    2017-02-01

    Self-expandable metal stents (SEMS) are thought to have an advantage over plastic stents in achieving biliary drainage. We performed a systematic search of MEDLINE, EMBASE, Scopus, CENTRAL, and ISI Web of knowledge databases, from January 1980 to September 2015, for randomized-controlled trials (RCTs) comparing SEMS vs. plastic stents in the palliation of malignant biliary obstruction. Primary outcomes were durations of stent patency, patient survival, and 30-day mortality. Numerous secondary outcomes were assessed, and extensive sensitivity and subgroup analyses were performed. In all, 20 RCTs totaling 1,713 patients yielded a weighted mean difference (WMD) in time to stent patency (4 studies) of 4.45 months (95% confidence interval (CI), 0.31, 8.59; GRADE=moderate) favoring SEMS. There were no differences in overall patient survival (5 studies) WMD=0.67 months (95% CI, -0.66, 1.99; GRADE=moderate), or 30-day mortality (8 studies) odds ratio (OR)=0.80 (95% CI, 0.52, 1.24; GRADE=moderate) but there was a higher symptom-free survival at 6 months (4 studies) OR=5.96 (95% CI, 1.71, 20.81; GRADE=moderate). SEMS use resulted in lower rates of late complications (11 studies) OR=0.43 (95% CI, 0.26, 0.71; GRADE=moderate), sepsis or cholangitis (14 studies) OR=0.53 (95% CI, 0.37, 0.77; GRADE=high), blocking from sludge (8 studies) OR=0.11(95% CI, 0.07, 0.17; GRADE=moderate), and mean number of re-interventions (8 studies) WMD=-0.83 interventions (95% CI, -1.64, -0.02; GRADE=moderate). There was a longer patency of SEMS for those without a prior drainage attempt (2 studies) WMD 7.70 months (95% CI, 7.14, 8.25; GRADE=high). Although a survival advantage was found when an uncovered SEMS was used (3 studies) WMD 1.31 months (95% CI, 0.30, 2.32; GRADE=high), but not partially or fully covered SEMS (2 studies) WMD -0.66 months (95% CI, -1.02, -0.30; GRADE=high) vs. plastic stents, and for SEMS in the setting of pre- or post-procedural antibiotic administration (2 studies) WMD 1

  5. Biocompatible epoxy modified bio-based polyurethane nanocomposites: mechanical property, cytotoxicity and biodegradation.

    Science.gov (United States)

    Dutta, Suvangshu; Karak, Niranjan; Saikia, Jyoti Prasad; Konwar, Bolin Kumar

    2009-12-01

    Epoxy modified Mesua ferrea L. seed oil (MFLSO) based polyurethane nanocomposites with different weight % of clay loadings (1%, 2.5% and 5%) have been evaluated as biocompatible materials. The nanocomposites were prepared by ex situ solution technique under high mechanical shearing and ultrasonication at room temperature. The partially exfoliated nanocomposites were characterized by Fourier transform infra-red (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM) techniques. The mechanical properties such as tensile strength and scratch hardness were improved 2 and 5 times, respectively by nanocomposites formation. Even the impact resistance improved a little. The thermostability of the nanocomposites was enhanced by about 40 degrees C. Biodegradation study confirmed 5-10 fold increase in biodegradation rate for the nanocomposites compared to the pristine polymers. All the nanocomposites showed non-cytotoxicity as evident from RBC hemolysis inhibition observed in anti-hemolytic assay carried over the sterilized films. The study reveals that the epoxy modified MFLSO based polyurethane nanocomposites deserve the potential to be applicable as biomaterials.

  6. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.

    Science.gov (United States)

    Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Sato, Yuki; Hikichi, Takuto; Ohira, Hiromasa

    2017-09-14

    To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents (SEMSs). This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography (ERCP) procedures between the two groups. The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices (ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve (sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement.

  7. Treatment of intracranial wide neck aneurysm with neuroform self-expanding stent combined with spring coils

    International Nuclear Information System (INIS)

    Bai Weixing; Jiang Xifeng; Li Tianxiao; Zhai Shuiting; Xue Jiangyu; Wang Ziliang; Cao Huicun

    2008-01-01

    Objective: To evaluate the preliminary experience of the combined self-expanding neurovascular stent (Neuroform stent) with detachable coils in the management of intracranial wide neck aneurysms. Methods: Self-expanding neurovascular stents with detachable coils were used in treating 27 intracranial wide neck aneurysms of 25 patients including cavernous segment ICA aneurysms in 3, ophthalmic arterial anemysm in 1, PcomA in 18, AcomA in 2, MCAM1 in 1, MCA bifurcation in 1, and basilar trunk in 1. Among them, 2 cases consisted of multi-aneurysms, 2 aneurysms coincide with absolute wide neck (> 4 mm) and 6 with comparatively wide neck (> 7 mm). Nemoform stents were deployed across the neck of aneurysm and detachable coils were released to embolize the aneurysm through stent mesh. Results: Twenty-six Neuroform stents were successfully deployed in 25 patients including 4 Neuroform II stents, and 22 Neurofom III stents(all combined with spring coils). Total occlusion was achieved in 7 patients with residual neck in 9 nearly complete occlusion and partial occlusion in 11. 2 patients were rebleeding and other 2 showed intra-stent thrombosis during the operations. The latter 2 included 1 with post-operative limb paraplegia and 1 died. Still another 1 had transient ischemic attack after the operation. Twenty-three patient recovered well. Twenty-four patients were under clinical followed up from 0.5 to 28 months with an average of 10.8 months. There was no bleeding. Three patients were angiographically followed up for 3-6 months after the procedure, with only 1 case of in-stent thrombosis and no change in other 2 aneurysms with neck remnant. Conclusions: The Neuroform stent is technically feasible and safe for treating intracranial wide neck aneurysms unsuitable for clipping because of its prevention for coil protruding into parent artery. The long term effect still need to be further investigated. (authors)

  8. Morphology and damping behavior of polyurethane/PMMA simultaneous interpenetrating networks

    Directory of Open Access Journals (Sweden)

    Wang S.H.

    2001-01-01

    Full Text Available A series of polyurethane/PMMA simultaneous interpenetrating networks (SINs with various hard segment contents (X in the polyurethane phase (X = 15.5 to 36.5% in polyurethane and wide range of polyurethane (PU to polyacrylate (PA ratio (PU/PA = 20:80 to 80:20 were prepared, and the damping and mechanical properties of these materials were studied. The damping of polyurethane soft phase was increased and shifted to lower temperature with increased content of PA vitreous phase. The mechanical properties were improved with increasing PA contents. The results show that PA and the polyurethane hard segment interaction play a special role in chain interpenetration density and its magnitude is revealed by the decreased dispersed domain size observed by scanning electron microscopy (SEM and increased loss area as measured by dynamic mechanical thermal analysis (DMTA. When the weight ratio of PU/PA was 40:60, the resulting SIN materials possessed better damping properties, independent of X concentration.

  9. Preparation and Characterization of Fluorinated Hydrophobic UV-Crosslinkable Thiol-Ene Polyurethane Coatings

    Directory of Open Access Journals (Sweden)

    Wenjing Xia

    2017-08-01

    Full Text Available The polyurethane prepolymer terminated with a double bond was synthesized using isophorone diisocyanate (IPDI, hydroxyl terminated polybutadiene (HTPB, 1,4-butanediol (BDO, and 2-hydroxyethyl acrylate (HEA. Then, a series of innovative UV-curable polyurethane coatings were prepared by blending ene-terminated polyurethane, fluoroacrylate monomer, and multifunctional thiol crosslinker upon UV exposure. The incorporation of fluoroacrylate monomer and multifunctional thiols into polyurethane coatings significantly enhanced the hydrophobic property, mechanical property, pencil hardness, and glossiness of the polyurethane coatings. This method of preparing UV crosslinkable, hydrophobic polyurethane coatings based on thiol-ene chemistry exhibited numerous advantages over other UV photocuring systems.

  10. Chemico-physical characterisation and in vivo biocompatibility assessment of DLC-coated coronary stents.

    Science.gov (United States)

    Castellino, Micaela; Stolojan, Vlad; Virga, Alessandro; Rovere, Massimo; Cabiale, Karine; Galloni, Marco R; Tagliaferro, Alberto

    2013-01-01

    The vast majority of stent thrombosis occurs in the acute and sub-acute phases and is more common in patients with acute coronary syndromes, due to the thrombotic milieu where stent struts are positioned. Stent thrombosis is likely due to incomplete tissue coverage of metallic stents as the contact between metallic stents and blood elements may lead to platelet adhesion and trigger vessel thrombosis. If a stent is covered after 7 days, the risk that it will be found uncovered at later stages is very low (DLC) coatings, deposited by physical vapour deposition, promote rapid endothelisation of coronary stent devices, with very low platelets activation, reducing thrombotic clots. We relate these behaviours to the surface and bulk material properties of the DLC films, subjected to a comprehensive chemico-physical characterisation using several techniques (X-ray photoelectron spectroscopy, atomic force microscopy, field-emission scanning electron microscope, transmission electron microscopy combined with electron energy loss spectroscopy, Raman and dispersive X-ray spectroscopy). In vivo studies, conducted on 24 pigs, have shown complete endothelisation after 7 days, with no fibrin mesh and with only rare monocytes scattered on the endothelial layer while 30 and 180 days tests have shown reduced inflammatory activation and a complete stabilisation of the vessel healing, with a minimal neointimal proliferation. The integral and permanent DLC film coating improves haemo- and bio-compatibility and leads to an excellent early vessel healing of the stent whilst the extremely thin strut thickness reduces the amount of late neointima and consequently the risk of late restenosis. These data should translate into a reduced acute and sub-acute stent thrombosis.

  11. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  12. A method to determine the kink resistance of stents and stent delivery systems according to international standards

    Directory of Open Access Journals (Sweden)

    Brandt-Wunderlich Christoph

    2016-09-01

    Full Text Available The kink behavior of vascular stents is of particular interest for clinicians, stent manufacturers and regulatory as a kinked stent generates a lumen loss in the stented vessel and can lead to in-stent restenosis. In this study methods to determine the kink resistance of stents and stent delivery systems according to the ISO 25539-2 and FDA guidance no. 1545 were presented. The methods are applicable for balloon expandable stents as well as for self-expanding stents and determine the lumen loss and residual diameter change dependent on the specific bending radius.

  13. Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.

    Science.gov (United States)

    Fan, Zhenmin; Liu, Xiao; Sun, Anqiang; Zhang, Nan; Fan, Zhanming; Fan, Yubo; Deng, Xiaoyan

    2017-10-01

    Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the possibility, we constructed a patient-specific carotid model with two components of plaques (lipid and calcified plaque) based on MRI images; we numerically compared three different stenting scenarios in terms of von Mises stress (VMS) distribution in the treated arteries, namely, the short stenting (LAM), the medium stenting and the long stenting. The results showed that the short stenting led to more areas with abnormally high VMS along the inner surface of the treated artery with a much higher surface-averaged VMS at the distal end of the stent than both the medium and long stenting. While the VMS distribution in the calcified plaques was similar for the three stenting models, it was quite different in the lipid plaques among the three stenting models. The lipid plaque of the short-stent model showed more volume of the lipid plaque subjected to high VMS than those of the other two models. Based on the obtained results, we may infer that the short stenting (i.e., LAM) may aggravate vascular injury due to high VMS on the artery-stent interaction surface and within the lipid plaque. Therefore, to obtain a better outcome, a longer stent, rather than a short one, might be needed for arterial stenting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Development of a New Hanging-Type Esophageal Stent for Preventing Migration: A Preliminary Study in an Animal Model of Esophagotracheal Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Masayuki, E-mail: masay010@yahoo.co.jp; Kaminou, Toshio, E-mail: kaminout@med.tottori-u.ac.jp; Ohuchi, Yasufumi, E-mail: oyasu@med.tottori-u.ac.jp [Tottori University, Department of Radiology, Faculty of Medicine (Japan); Sugiura, Kimihiko, E-mail: kimihikosugiura@gmail.com [Yonago Medical Center, Department of Radiology (Japan); Yata, Shinsaku, E-mail: yata-s@med.tottori-u.ac.jp; Adachi, Akira, E-mail: july1st@med.tottori-u.ac.jp; Kawai, Tsuyoshi, E-mail: prgr-xxio@kuc.biglobe.ne.jp; Takasugi, Syohei, E-mail: stakasugi@med.tottori-u.ac.jp; Yamamoto, Shuichi, E-mail: yamamotoshu@med.tottori-u.ac.jp; Matsumoto, Kensuke, E-mail: matsumoto-k@v103.vaio.ne.jp [Tottori University, Department of Radiology, Faculty of Medicine (Japan); Hashimoto, Masayuki, E-mail: hashimotom@pref.tottori.jp [Tottori Prefectural Kosei Hospital, Department of Radiology (Japan); Ihaya, Takashi, E-mail: iahaya@orange.ocn.ne.jp [Sanin Rosai Hospital, Department of Radiology (Japan); Ogawa, Toshihide, E-mail: ogawa@med.tottori-u.ac.jp [Tottori University, Department of Radiology, Faculty of Medicine (Japan)

    2012-10-15

    Purpose: Covered, self-expandable metallic stents (SEMS) have been enthusiastically adopted for the treatment of esophagotracheal fistula, but problems with stent migration have yet to be resolved. To overcome this problem, we have developed a new hanging-type esophageal stent designed to prevent migration, and we conducted an animal study to assess the efficacy of our method. Methods: A total of six female pigs were used in this study. The main characteristic of our stent was the presence of a string tied to the proximal edge of the stent for fixation under the skin of the neck. The first experiment was performed to confirm technical feasibility in three pigs with esophagotracheal fistula. The second experiment was performed to evaluate stent migration and esophagotracheal fistula in three pigs. Results: Creation of the esophagotracheal fistula and stent placement were technically successful in all pigs. In the first experiment, esophagotracheal fistula was sealed by stent placement. In the second experiment, no stent migration was seen 11 or 12 days after stent placement. Gross findings showed no fistulas on the esophageal or tracheal wall. Conclusions: Our new hanging-type esophageal stent seems to offer a feasible method for preventing stent migration.

  15. Development of a New Hanging-Type Esophageal Stent for Preventing Migration: A Preliminary Study in an Animal Model of Esophagotracheal Fistula

    International Nuclear Information System (INIS)

    Endo, Masayuki; Kaminou, Toshio; Ohuchi, Yasufumi; Sugiura, Kimihiko; Yata, Shinsaku; Adachi, Akira; Kawai, Tsuyoshi; Takasugi, Syohei; Yamamoto, Shuichi; Matsumoto, Kensuke; Hashimoto, Masayuki; Ihaya, Takashi; Ogawa, Toshihide

    2012-01-01

    Purpose: Covered, self-expandable metallic stents (SEMS) have been enthusiastically adopted for the treatment of esophagotracheal fistula, but problems with stent migration have yet to be resolved. To overcome this problem, we have developed a new hanging-type esophageal stent designed to prevent migration, and we conducted an animal study to assess the efficacy of our method. Methods: A total of six female pigs were used in this study. The main characteristic of our stent was the presence of a string tied to the proximal edge of the stent for fixation under the skin of the neck. The first experiment was performed to confirm technical feasibility in three pigs with esophagotracheal fistula. The second experiment was performed to evaluate stent migration and esophagotracheal fistula in three pigs. Results: Creation of the esophagotracheal fistula and stent placement were technically successful in all pigs. In the first experiment, esophagotracheal fistula was sealed by stent placement. In the second experiment, no stent migration was seen 11 or 12 days after stent placement. Gross findings showed no fistulas on the esophageal or tracheal wall. Conclusions: Our new hanging-type esophageal stent seems to offer a feasible method for preventing stent migration.

  16. Double-chain phospholipid end-capped polyurethanes: Synthesis, characterization and platelet adhesion study

    International Nuclear Information System (INIS)

    Tan Dongsheng; Zhang Xiaoqing; Li Jiehua; Tan Hong; Fu Qiang

    2012-01-01

    A novel phospholipid containing double chains and phosphotidylcholine polar head groups, 2-(10-(2-aminoethylamino)-10-oxodecanamido)-3-(decyloxy)-3-oxopropyl phosphorylcholine (ADDPC), was synthesized and characterized. Two kinds of double-chain phospholipid end-capped polyurethanes with different soft segments were prepared. The structure of prepared polyurethanes was characterized by X-ray photoelectron spectroscopic (XPS), attenuated total reflection Fourier transform infrared (ATR-FTIR) spectrometry and atomic force microscope (AFM), which indicated that the double-chain phospholipids enriched onto the top surface of the prepared polyurethane films. The preliminary evaluation of blood compatibility showed that these novel phospholipid end-capped polyurethanes could suppress platelet adhesion and activation effectively. This property did not depend on the chemical structure of polyurethanes. In addition, according to tensile test results, the phospholipid polyurethanes kept good mechanical properties in comparison with original polyurethanes. It is suggested that double-chain phospholipid end-caption has good potential for achieving both hemocompatibility and good mechanical properties simultaneously for polyurethanes.

  17. Peripheral Stent Thrombosis Leading to Acute Limb Ischemia and Major Amputation: Incidence and Risk Factors in the Aortoiliac and Femoropopliteal Arteries

    International Nuclear Information System (INIS)

    Katsanos, Konstantinos; Al-Lamki, Said A. M.; Parthipun, Aneeta; Spiliopoulos, Stavros; Patel, Sanjay Dhanji; Paraskevopoulos, Ioannis; Zayed, Hany; Diamantopoulos, Athanasios

    2017-01-01

    PurposeTo report the real-world incidence and risk factors of stent thrombosis in the aortoiliac and femoropopliteal arteries in case of bare nitinol stent (BNS) or covered nitinol stent (CNS) placement from a single-centre retrospective audit.Materials and MethodsMedical records of consecutive patients treated with peripheral stent placement for claudication or critical limb ischemia were audited for definite stent thrombosis defined as imaging confirmed stent thrombosis that presented as acute limb-threatening ischemia. Cases were stratified between aortoiliac and femoropopliteal anatomy. Cox regression analysis was employed to adjust for baseline clinical and procedural confounders and identify predictors of stent thrombosis and major limb loss.Results256 patients (n = 277 limbs) were analysed over a 5-year period (2009–2014) including 117 aortoiliac stents (34 CNS; 12.8 ± 5.0 cm and 83 BNS; 7.8 ± 4.0 cm) and 160 femoropopliteal ones (60 CNS; 21.1 ± 11.0 cm and 100 BNS; 17.5 ± 11.9 cm). Median follow-up was 1 year. Overall stent thrombosis rate was 6.1% (17/277) after a median of 43 days (range 2–192 days) and affected almost exclusively the femoropopliteal segment (12/60 in the CNS cohort vs. 4/100 in the BNS; p = 0.001). Annualized stent thrombosis rates (per 100 person-years) were 12.5% in case of CNS and 1.4% in case of BNS (HR 6.3, 95% CI 2.4–17.9; p = 0.0002). Corresponding major amputations rates were 8.7 and 2.5%, respectively (HR 4.5, 95% CI 2.7–27.9; p = 0.0006). On multivariable analysis, critical leg ischemia and CNS placement were the only predictors of stent thrombosis. Diabetes, critical leg ischemia, femoropopliteal anatomy, long stents and CNS were independent predictors of major amputations.ConclusionsPlacement of long femoropopliteal covered nitinol stents is associated with an increased incidence of acute stent thrombosis and ensuing major amputation. Risks are significantly lower in the aortoiliac vessels

  18. Peripheral Stent Thrombosis Leading to Acute Limb Ischemia and Major Amputation: Incidence and Risk Factors in the Aortoiliac and Femoropopliteal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Imaging Sciences Division, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Al-Lamki, Said A. M. [The Royal Hospital, Department of Radiology (Oman); Parthipun, Aneeta [King’s Health Partners, Department of Interventional Radiology, Imaging Sciences Division, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Spiliopoulos, Stavros [ATTIKO Athens University Hospital, 2nd Department of Radiology, Interventional Radiology Unit (Greece); Patel, Sanjay Dhanji [King’s Health Partners, Academic Department of Surgery, Cardiovascular Division, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Paraskevopoulos, Ioannis [King’s Health Partners, Department of Interventional Radiology, Imaging Sciences Division, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Zayed, Hany [King’s Health Partners, Academic Department of Surgery, Cardiovascular Division, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Diamantopoulos, Athanasios [King’s Health Partners, Department of Interventional Radiology, Imaging Sciences Division, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2017-03-15

    PurposeTo report the real-world incidence and risk factors of stent thrombosis in the aortoiliac and femoropopliteal arteries in case of bare nitinol stent (BNS) or covered nitinol stent (CNS) placement from a single-centre retrospective audit.Materials and MethodsMedical records of consecutive patients treated with peripheral stent placement for claudication or critical limb ischemia were audited for definite stent thrombosis defined as imaging confirmed stent thrombosis that presented as acute limb-threatening ischemia. Cases were stratified between aortoiliac and femoropopliteal anatomy. Cox regression analysis was employed to adjust for baseline clinical and procedural confounders and identify predictors of stent thrombosis and major limb loss.Results256 patients (n = 277 limbs) were analysed over a 5-year period (2009–2014) including 117 aortoiliac stents (34 CNS; 12.8 ± 5.0 cm and 83 BNS; 7.8 ± 4.0 cm) and 160 femoropopliteal ones (60 CNS; 21.1 ± 11.0 cm and 100 BNS; 17.5 ± 11.9 cm). Median follow-up was 1 year. Overall stent thrombosis rate was 6.1% (17/277) after a median of 43 days (range 2–192 days) and affected almost exclusively the femoropopliteal segment (12/60 in the CNS cohort vs. 4/100 in the BNS; p = 0.001). Annualized stent thrombosis rates (per 100 person-years) were 12.5% in case of CNS and 1.4% in case of BNS (HR 6.3, 95% CI 2.4–17.9; p = 0.0002). Corresponding major amputations rates were 8.7 and 2.5%, respectively (HR 4.5, 95% CI 2.7–27.9; p = 0.0006). On multivariable analysis, critical leg ischemia and CNS placement were the only predictors of stent thrombosis. Diabetes, critical leg ischemia, femoropopliteal anatomy, long stents and CNS were independent predictors of major amputations.ConclusionsPlacement of long femoropopliteal covered nitinol stents is associated with an increased incidence of acute stent thrombosis and ensuing major amputation. Risks are significantly lower in the aortoiliac vessels

  19. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    Science.gov (United States)

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  20. [A case of recurrent transverse colon cancer invading the pancreas and duodenum successfully treated with biliary and duodenal stenting].

    Science.gov (United States)

    Tonooka, Toru; Yoshioka, Shigeru; Shiobara, Masayuki; Wakatsuki, Kazuo; Kataoka, Masaaki; Arai, Shuka; Miyazawa, Kotaro; Nakada, Shinichiro; Kita, Kazuhiko; Saito, Hirofumi; Nomoto, Hiromasa; Usui, Masatoshi; Yabiki, Masashi; Ota, Yuki; Oeda, Yoshio

    2013-11-01

    We report a case of recurrent transverse colon cancer invading the pancreas and duodenum that was successfully treated with biliary and duodenal stenting. A 46-year-old man underwent ascending colostomy for the treatment of obstructive transverse colon cancer with hepatic metastasis. Chemotherapy achieved a partial response, but the levels of tumor markers later began to rise again. He then underwent right hemicolectomy and partial hepatectomy. Post-operative chemotherapy was administered, but the recurrent tumor caused obstructive jaundice and duodenal obstruction. These were successfully treated with biliary and duodenal stenting, and the patient was able to remain at home and maintain his quality of life.