WorldWideScience

Sample records for partially occluded image

  1. A System for Automatic Detection of Partially Occluded Objects from Real-World Images

    National Research Council Canada - National Science Library

    Neskovic, Predrag; Wu, Liang; Cooper, Leon N

    2006-01-01

    In this work we consider the Bayesian Integrate And Shift (BIAS) model for learning object categories and test its performance on learning and recognizing different object categories from real-world images...

  2. Reliable Recognition of Partially Occluded Objects with Correlation Filters

    Directory of Open Access Journals (Sweden)

    Alexey Ruchay

    2018-01-01

    Full Text Available Design of conventional correlation filters requires explicit knowledge of the appearance and shape of a target object, so the performance of correlation filters is significantly affected by changes in the appearance of the object in the input scene. In particular, the performance of correlation filters worsens when objects to be recognized are partially occluded by other objects, and the input scene contains a cluttered background and noise. In this paper, we propose a new algorithm for the design of a system consisting of a set of adaptive correlation filters for recognition of partially occluded objects in noisy scenes. Since the input scene may contain different fragments of the target, false objects, and background to be rejected, the system is designed in such a manner to guarantee equally high correlation peaks corresponding to parts of the target in the scenes. The key points of the system are as follows: (i it consists of a bank of composite optimum filters, which yield the best performance for different parts of the target; (ii it includes a fragmentation of the target into a given number of parts in the training stage to provide equal intensity responses of the system for each part of the target. With the help of computer simulation, the performance of the proposed algorithm for recognition partially occluded objects is compared with that of common algorithms in terms of objective metrics.

  3. Detection scheme for a partially occluded pedestrian based on occluded depth in lidar-radar sensor fusion

    Science.gov (United States)

    Kwon, Seong Kyung; Hyun, Eugin; Lee, Jin-Hee; Lee, Jonghun; Son, Sang Hyuk

    2017-11-01

    Object detections are critical technologies for the safety of pedestrians and drivers in autonomous vehicles. Above all, occluded pedestrian detection is still a challenging topic. We propose a new detection scheme for occluded pedestrian detection by means of lidar-radar sensor fusion. In the proposed method, the lidar and radar regions of interest (RoIs) have been selected based on the respective sensor measurement. Occluded depth is a new means to determine whether an occluded target exists or not. The occluded depth is a region projected out by expanding the longitudinal distance with maintaining the angle formed by the outermost two end points of the lidar RoI. The occlusion RoI is the overlapped region made by superimposing the radar RoI and the occluded depth. The object within the occlusion RoI is detected by the radar measurement information and the occluded object is estimated as a pedestrian based on human Doppler distribution. Additionally, various experiments are performed in detecting a partially occluded pedestrian in outdoor as well as indoor environments. According to experimental results, the proposed sensor fusion scheme has much better detection performance compared to the case without our proposed method.

  4. Transgastric endoscopic gastroenterostomy using a partially covered occluder: a canine feasibility study.

    Science.gov (United States)

    Luo, H; Pan, Y; Min, L; Zhao, L; Li, J; Leung, J; Xue, L; Yin, Z; Liu, X; Liu, Z; Sun, A; Li, C; Wu, K; Guo, X; Fan, D

    2012-05-01

    The use of natural orifice transluminal endoscopic surgery (NOTES) for gastroenterostomy has been previously reported, but it remains technically challenging and additional assistance is often needed. The aim of this study was to develop and evaluate a novel method for the creation of a gastroenterostomy using NOTES with an occluder. Transgastric endoscopic gastroenterostomy was performed in 12 healthy female dogs using a therapeutic upper gastrointestinal endoscope and a partially covered occluder. The occluder was removed with a snare 1 week later. The patency of the gastroenterostomy was confirmed by endoscopy, contrast radiological study, necropsy, and histological examination after 2 weeks. NOTES gastroenterostomy with an occluder was successful in all 12 dogs. The mean operative time was 32.3 ± 10.3 min (range 20.3 - 53.5). One dog (the first; 8.3 %) died 4 days after the operation of severe intra-abdominal infection due to incorrect deployment of the occluder and poor bowel preparation. Minor bleeding occurred at the anastomosis after removal of the occluder in two of the remaining dogs (18.2 %). Necropsy revealed postoperative adhesions that had developed at the anastomotic site in one dog (9.1 %). No anastomotic leakage or intestinal obstruction was observed. Complete healing of the anastomosis was confirmed on histological evaluation. Gastroenterostomy performed entirely by NOTES using an occluder was technically feasible in this survival animal model. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Towards Robust and Accurate Multi-View and Partially-Occluded Face Alignment.

    Science.gov (United States)

    Xing, Junliang; Niu, Zhiheng; Huang, Junshi; Hu, Weiming; Zhou, Xi; Yan, Shuicheng

    2018-04-01

    Face alignment acts as an important task in computer vision. Regression-based methods currently dominate the approach to solving this problem, which generally employ a series of mapping functions from the face appearance to iteratively update the face shape hypothesis. One keypoint here is thus how to perform the regression procedure. In this work, we formulate this regression procedure as a sparse coding problem. We learn two relational dictionaries, one for the face appearance and the other one for the face shape, with coupled reconstruction coefficient to capture their underlying relationships. To deploy this model for face alignment, we derive the relational dictionaries in a stage-wised manner to perform close-loop refinement of themselves, i.e., the face appearance dictionary is first learned from the face shape dictionary and then used to update the face shape hypothesis, and the updated face shape dictionary from the shape hypothesis is in return used to refine the face appearance dictionary. To improve the model accuracy, we extend this model hierarchically from the whole face shape to face part shapes, thus both the global and local view variations of a face are captured. To locate facial landmarks under occlusions, we further introduce an occlusion dictionary into the face appearance dictionary to recover face shape from partially occluded face appearance. The occlusion dictionary is learned in a data driven manner from background images to represent a set of elemental occlusion patterns, a sparse combination of which models various practical partial face occlusions. By integrating all these technical innovations, we obtain a robust and accurate approach to locate facial landmarks under different face views and possibly severe occlusions for face images in the wild. Extensive experimental analyses and evaluations on different benchmark datasets, as well as two new datasets built by ourselves, have demonstrated the robustness and accuracy of our proposed

  6. Immediate occluding definitive partial fixed prosthesis versus non-occluding provisional restorations - 4-month post-loading results from a pragmatic multicenter randomised controlled trial.

    Science.gov (United States)

    Heinemann, Friedhelm; Grufferty, Brendan; Papavasiliou, George; Dominiak, Marzena; García, Jaime Jiménez; Trullenque-Eriksson, Anna; Esposito, Marco

    2016-01-01

    To compare the clinical outcome of dental implants restored with definitive occluding partial fixed prostheses within 1 week, after implant placement with immediate non-occluding provisional restorations, which were to be replaced by definitive prostheses after 4 months. Fifty partially edentulous patients treated with one to three dental implants, at least 8.5 mm long and 4.0 mm wide inserted with a torque of at least 35 Ncm, were randomised in two groups of 25 patients each, to be immediately loaded with partial fixed prostheses. Patients of one group received one definitive screw-retained metal-ceramic prosthesis in occlusion within 1 week after placement. Patients of the other group received one non-occluding provisional acrylic reinforced prosthesis within 24 h after implant placement. Provisional prostheses were replaced after 4 months by definitive ones. The follow-up for all patients was 4-months post-loading. Outcome measures were prosthesis and implant failures, any complications, peri-implant marginal bone level changes, aesthetic evaluation by a clinician, patient satisfaction, chair time and number of visits at the dental office from implant placement to delivery of definitive restorations. No patient dropped out. Two immediately occlusally loaded implants with their related definitive prostheses (8%) failed early (difference in proportions = 0.08; 95% CI: -0.03 to 0.19; P = 0.490). Four complications occurred in the occlusal group versus one in the non-occlusal group; (difference in proportions = 0.12; 95% CI: -0.04 to 0.28; P = 0.349). Four months after loading, patients subjected to non-occlusal loading lost an average of 0.72 mm of peri-implant bone versus 0.99 mm of patients restored with occluding definitive partial fixed prostheses. There were no statistically significant differences for marginal bone level changes between the two groups (mean difference = -0.27 mm; 95% CI: -0.84 to 0.30; P = 0.349). The differences for aesthetic scores showed

  7. Iris Recognition for Partially Occluded Images: Methodology and Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    Poursaberi A

    2007-01-01

    Full Text Available Accurate iris detection is a crucial part of an iris recognition system. One of the main issues in iris segmentation is coping with occlusion that happens due to eyelids and eyelashes. In the literature, some various methods have been suggested to solve the occlusion problem. In this paper, two different segmentations of iris are presented. In the first algorithm, a circle is located around the pupil with an appropriate diameter. The iris area encircled by the circular boundary is used for recognition purposes then. In the second method, again a circle is located around the pupil with a larger diameter. This time, however, only the lower part of the encircled iris area is utilized for individual recognition. Wavelet-based texture features are used in the process. Hamming and harmonic mean distance classifiers are exploited as a mixed classifier in suggested algorithm. It is observed that relying on a smaller but more reliable part of the iris, though reducing the net amount of information, improves the overall performance. Experimental results on CASIA database show that our method has a promising performance with an accuracy of 99.31%. The sensitivity of the proposed method is analyzed versus contrast, illumination, and noise as well, where lower sensitivity to all factors is observed when the lower half of the iris is used for recognition.

  8. Weight dependent modulation of motor resonance induced by weight estimation during observation of partially occluded lifting actions.

    Science.gov (United States)

    Valchev, Nikola; Zijdewind, Inge; Keysers, Christian; Gazzola, Valeria; Avenanti, Alessio; Maurits, Natasha M

    2015-01-01

    Seeing others performing an action induces the observers' motor cortex to "resonate" with the observed action. Transcranial magnetic stimulation (TMS) studies suggest that such motor resonance reflects the encoding of various motor features of the observed action, including the apparent motor effort. However, it is unclear whether such encoding requires direct observation or whether force requirements can be inferred when the moving body part is partially occluded. To address this issue, we presented participants with videos of a right hand lifting a box of three different weights and asked them to estimate its weight. During each trial we delivered one transcranial magnetic stimulation (TMS) pulse over the left primary motor cortex of the observer and recorded the motor evoked potentials (MEPs) from three muscles of the right hand (first dorsal interosseous, FDI, abductor digiti minimi, ADM, and brachioradialis, BR). Importantly, because the hand shown in the videos was hidden behind a screen, only the contractions in the actor's BR muscle under the bare skin were observable during the entire videos, while the contractions in the actor's FDI and ADM muscles were hidden during the grasp and actual lift. The amplitudes of the MEPs recorded from the BR (observable) and FDI (hidden) muscle increased with the weight of the box. These findings indicate that the modulation of motor excitability induced by action observation extends to the cortical representation of muscles with contractions that could not be observed. Thus, motor resonance appears to reflect force requirements of observed lifting actions even when the moving body part is occluded from view. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Intra-arterial high signals on arterial spin labeling perfusion images predict the occluded internal carotid artery segment

    International Nuclear Information System (INIS)

    Sogabe, Shu; Satomi, Junichiro; Tada, Yoshiteru; Kanematsu, Yasuhisa; Kuwayama, Kazuyuki; Yagi, Kenji; Yoshioka, Shotaro; Mizobuchi, Yoshifumi; Mure, Hideo; Yamaguchi, Izumi; Kitazato, Keiko T.; Nagahiro, Shinji; Abe, Takashi; Harada, Masafumi; Yamamoto, Nobuaki; Kaji, Ryuji

    2017-01-01

    Arterial spin labeling (ASL) involves perfusion imaging using the inverted magnetization of arterial water. If the arterial arrival times are longer than the post-labeling delay, labeled spins are visible on ASL images as bright, high intra-arterial signals (IASs); such signals were found within occluded vessels of patients with acute ischemic stroke. The identification of the occluded segment in the internal carotid artery (ICA) is crucial for endovascular treatment. We tested our hypothesis that high IASs on ASL images can predict the occluded segment. Our study included 13 patients with acute ICA occlusion who had undergone angiographic and ASL studies within 48 h of onset. We retrospectively identified the high IAS on ASL images and angiograms and recorded the occluded segment and the number of high IAS-positive slices on ASL images. The ICA segments were classified as cervical (C1), petrous (C2), cavernous (C3), and supraclinoid (C4). Of seven patients with intracranial ICA occlusion, five demonstrated high IASs at C1-C2, suggesting that high IASs could identify stagnant flow proximal to the occluded segment. Among six patients with extracranial ICA occlusion, five presented with high IASs at C3-C4, suggesting that signals could identify the collateral flow via the ophthalmic artery. None had high IASs at C1-C2. The mean number of high IAS-positive slices was significantly higher in patients with intra- than extracranial ICA occlusion. High IASs on ASL images can identify slow stagnant and collateral flow through the ophthalmic artery in patients with acute ICA occlusion and help to predict the occlusion site. (orig.)

  10. Intra-arterial high signals on arterial spin labeling perfusion images predict the occluded internal carotid artery segment

    Energy Technology Data Exchange (ETDEWEB)

    Sogabe, Shu; Satomi, Junichiro; Tada, Yoshiteru; Kanematsu, Yasuhisa; Kuwayama, Kazuyuki; Yagi, Kenji; Yoshioka, Shotaro; Mizobuchi, Yoshifumi; Mure, Hideo; Yamaguchi, Izumi; Kitazato, Keiko T.; Nagahiro, Shinji [Tokushima University Graduate School, Department of Neurosurgery, Tokushima (Japan); Abe, Takashi; Harada, Masafumi [Tokushima University Graduate School, Department of Radiology, Tokushima (Japan); Yamamoto, Nobuaki; Kaji, Ryuji [Tokushima University Graduate School, Department of Clinical Neurosciences, Institute of Biomedical Biosciences, Tokushima (Japan)

    2017-06-15

    Arterial spin labeling (ASL) involves perfusion imaging using the inverted magnetization of arterial water. If the arterial arrival times are longer than the post-labeling delay, labeled spins are visible on ASL images as bright, high intra-arterial signals (IASs); such signals were found within occluded vessels of patients with acute ischemic stroke. The identification of the occluded segment in the internal carotid artery (ICA) is crucial for endovascular treatment. We tested our hypothesis that high IASs on ASL images can predict the occluded segment. Our study included 13 patients with acute ICA occlusion who had undergone angiographic and ASL studies within 48 h of onset. We retrospectively identified the high IAS on ASL images and angiograms and recorded the occluded segment and the number of high IAS-positive slices on ASL images. The ICA segments were classified as cervical (C1), petrous (C2), cavernous (C3), and supraclinoid (C4). Of seven patients with intracranial ICA occlusion, five demonstrated high IASs at C1-C2, suggesting that high IASs could identify stagnant flow proximal to the occluded segment. Among six patients with extracranial ICA occlusion, five presented with high IASs at C3-C4, suggesting that signals could identify the collateral flow via the ophthalmic artery. None had high IASs at C1-C2. The mean number of high IAS-positive slices was significantly higher in patients with intra- than extracranial ICA occlusion. High IASs on ASL images can identify slow stagnant and collateral flow through the ophthalmic artery in patients with acute ICA occlusion and help to predict the occlusion site. (orig.)

  11. Occluded object reconstruction for first responders with augmented reality glasses using conditional generative adversarial networks

    OpenAIRE

    Yun, Kyongsik; Lu, Thomas; Chow, Edward

    2018-01-01

    Firefighters suffer a variety of life-threatening risks, including line-of-duty deaths, injuries, and exposures to hazardous substances. Support for reducing these risks is important. We built a partially occluded object reconstruction method on augmented reality glasses for first responders. We used a deep learning based on conditional generative adversarial networks to train associations between the various images of flammable and hazardous objects and their partially occluded counterparts....

  12. Balloon-occluded Retrograde Transvenous Obliteration (BRTO): Technique and Intraprocedural Imaging

    Science.gov (United States)

    Sabri, Saher S.; Saad, Wael E. A.

    2011-01-01

    Balloon-occluded retrograde transvenous obliteration (BRTO) is an endovascular technique used as a therapeutic adjunct or alternative to transjugular intrahepatic shunts (TIPS) in the management of gastric varices. Occlusion balloons are strategically placed to modulate flow within the gastrorenal or gastrocaval shunt to allow stagnation of the sclerosant material within the gastric varix. The approach and complexity of the procedure depends on the anatomic classification of inflow and outflow veins of the varix. Ethanolamine oleate has been described as the main sclerosant used in this procedure. Recently, foam sclerosants have gained popularity as alternative embolization agents, which provide the advantage of better variceal wall contact and potentially less dose of sclerosant. PMID:22942548

  13. 3D noise-resistant segmentation and tracking of unknown and occluded objects using integral imaging

    Science.gov (United States)

    Aloni, Doron; Jung, Jae-Hyun; Yitzhaky, Yitzhak

    2017-10-01

    Three dimensional (3D) object segmentation and tracking can be useful in various computer vision applications, such as: object surveillance for security uses, robot navigation, etc. We present a method for 3D multiple-object tracking using computational integral imaging, based on accurate 3D object segmentation. The method does not employ object detection by motion analysis in a video as conventionally performed (such as background subtraction or block matching). This means that the movement properties do not significantly affect the detection quality. The object detection is performed by analyzing static 3D image data obtained through computational integral imaging With regard to previous works that used integral imaging data in such a scenario, the proposed method performs the 3D tracking of objects without prior information about the objects in the scene, and it is found efficient under severe noise conditions.

  14. Balloon-occluded Retrograde Transvenous Obliteration (BRTO): Preprocedural Evaluation and Imaging

    Science.gov (United States)

    Al-Osaimi, Abdullah M. S.; Sabri, Saher S.; Caldwell, Stephen H.

    2011-01-01

    Patients undergoing balloon retrograde transvenous obliteration (BRTO) are mostly decompensated cirrhotic with either bleeding gastric varices (GV) or hepatic encephalopathy. It is crucial that clinicians are up-to-date with the assessments needed prior to BRTO to anticipate and prevent complications, and to deliver critical quality care. These patients will require preprocedural assessments and management, including endoscopic, clinical, laboratory, and imaging evaluation. Endoscopic evaluation is mandatory prior to BRTO, and it is highly recommended that it be performed at the same institution where BRTO will be performed. It is essential that clinicians are aware of the potential benefits and complications that may result from BRTO. These complications should be anticipated and prevented when possible. For GV bleeders, there should be consideration of a transvenous intrahepatic portosystemic shunt (TIPS) during or before BRTO in patients with refractory ascites or pleural effusion, as well as endoscopic banding or a TIPS in patients with high-risk esophageal varices. Patients undergoing BRTO are usually complicated and require a team approach. In this article, the authors address these assessment and preparatory management and planning procedures prior to the BRTO procedure as well as expected outcomes and potential complications. PMID:22942546

  15. Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimatsu, Rika [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences (Japan); Yamagami, Takuji, E-mail: yamagami@kochi-u.ac.jp [Kochi University, Department of Radiology (Japan); Ishikawa, Masaki; Kajiwara, Kenji [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences (Japan); Aikata, Hiroshi; Chayama, Kazuaki [Hiroshima University, Department of Gastroenterology and Metabolism, Institute of Biomedical and Health Sciences (Japan); Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences (Japan)

    2016-06-15

    PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumor enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.

  16. Computational acceleration for MR image reconstruction in partially parallel imaging.

    Science.gov (United States)

    Ye, Xiaojing; Chen, Yunmei; Huang, Feng

    2011-05-01

    In this paper, we present a fast numerical algorithm for solving total variation and l(1) (TVL1) based image reconstruction with application in partially parallel magnetic resonance imaging. Our algorithm uses variable splitting method to reduce computational cost. Moreover, the Barzilai-Borwein step size selection method is adopted in our algorithm for much faster convergence. Experimental results on clinical partially parallel imaging data demonstrate that the proposed algorithm requires much fewer iterations and/or less computational cost than recently developed operator splitting and Bregman operator splitting methods, which can deal with a general sensing matrix in reconstruction framework, to get similar or even better quality of reconstructed images.

  17. ANNOTATION SUPPORTED OCCLUDED OBJECT TRACKING

    Directory of Open Access Journals (Sweden)

    Devinder Kumar

    2012-08-01

    Full Text Available Tracking occluded objects at different depths has become as extremely important component of study for any video sequence having wide applications in object tracking, scene recognition, coding, editing the videos and mosaicking. The paper studies the ability of annotation to track the occluded object based on pyramids with variation in depth further establishing a threshold at which the ability of the system to track the occluded object fails. Image annotation is applied on 3 similar video sequences varying in depth. In the experiment, one bike occludes the other at a depth of 60cm, 80cm and 100cm respectively. Another experiment is performed on tracking humans with similar depth to authenticate the results. The paper also computes the frame by frame error incurred by the system, supported by detailed simulations. This system can be effectively used to analyze the error in motion tracking and further correcting the error leading to flawless tracking. This can be of great interest to computer scientists while designing surveillance systems etc.

  18. Magnetic resonance imaging in complex partial seizures

    International Nuclear Information System (INIS)

    Furune, Sunao; Negoro, Tamiko; Maehara, Mitsuo; Nomura, Kazushi; Miura, Kiyokuni; Takahashi, Izumi; Watanabe, Kazuyoshi

    1989-01-01

    Magnetic resonance imaging (MRI) and computed tomography (CT) were performed on 45 patients with intractable complex partial seizures. MRI was performed with a superconducting whole-body scanner operating at 0.5 tesla (T) and 1.5 T. In patients with temporal lobe epilepsy, 8 of 24 patients had abnormal CT, but 16 or 24 patients showed abnormal MRI. 1.5 T MRI detected more abnormality than 0.5 T MRI when CT was normal. In patients with frontal lobe epilepsy, 5 of 7 patients had normal CT and MRI. In 2 other patients, MRI demonstrated an arachnoid cyst and increased signal intensity area on the T2-weighted images which were not detected by CT. In patients with occipital lobe epilepsy, 5 of 6 patients show abnormal CT and MRI. In patients with tuberous sclerosis, MRI revealed some increased signal intensity areas on the T2-weighted images in the occipital and temporal lobe, which were not detected by CT. Most surface EEG foci corresponded with the side of MRI abnormality. These data indicate that MRI is more informative than CT in complex partial seizures. MRI is the imaging technique of choice in the diagnosis of complex partial seizures. (author)

  19. Partially coherent imaging and spatial coherence wavelets

    International Nuclear Information System (INIS)

    Castaneda, Roman

    2003-03-01

    A description of spatially partially coherent imaging based on the propagation of second order spatial coherence wavelets and marginal power spectra (Wigner distribution functions) is presented. In this dynamics, the spatial coherence wavelets will be affected by the system through its elementary transfer function. The consistency of the model with the both extreme cases of full coherent and incoherent imaging was proved. In the last case we obtained the classical concept of optical transfer function as a simple integral of the elementary transfer function. Furthermore, the elementary incoherent response function was introduced as the Fourier transform of the elementary transfer function. It describes the propagation of spatial coherence wavelets form each object point to each image point through a specific point on the pupil planes. The point spread function of the system was obtained by a simple integral of the elementary incoherent response function. (author)

  20. Digital Particle Image Velocimetry: Partial Image Error (PIE)

    International Nuclear Information System (INIS)

    Anandarajah, K; Hargrave, G K; Halliwell, N A

    2006-01-01

    This paper quantifies the errors due to partial imaging of seeding particles which occur at the edges of interrogation regions in Digital Particle Image Velocimetry (DPIV). Hitherto, in the scientific literature the effect of these partial images has been assumed to be negligible. The results show that the error is significant even at a commonly used interrogation region size of 32 x 32 pixels. If correlation of interrogation region sizes of 16 x 16 pixels and smaller is attempted, the error which occurs can preclude meaningful results being obtained. In order to reduce the error normalisation of the correlation peak values is necessary. The paper introduces Normalisation by Signal Strength (NSS) as the preferred means of normalisation for optimum accuracy. In addition, it is shown that NSS increases the dynamic range of DPIV

  1. Diffusion tensor imaging of partial intractable epilepsy

    International Nuclear Information System (INIS)

    Dumas de la Roque, Anne; Oppenheim, Catherine; Rodrigo, Sebastian; Meder, Jean-Francois; Chassoux, Francine; Devaux, Bertrand; Beuvon, Frederic; Daumas-Duport, Catherine

    2005-01-01

    Our aim was to assess the value of diffusion tensor imaging (DTI) in patients with partial intractable epilepsy. We used DTI (25 non-collinear directions) in 15 patients with a cortical lesion on conventional MRI. Fractional anisotropy (FA) was measured in the internal capsule, and in the normal-appearing white matter (WM), adjacent tothe lesion, and away from the lesion, at a set distance of 2-3 cm. In each patient, increased or decreased FA measurements were those that varied from mirror values using an arbitrary 10% threshold. Over the whole population, ipsi- and contralateral FA measurements were also compared using a Wilcoxon test (p<0.05). Over the whole population, FA was significantly reduced in the WM adjacent to and away from the lesion, whilst being normal in the internal capsule. FA was reduced by more than 10% in the WM adjacent to and distant from the lesion in 13 and 12 patients respectively. For nine of the ten patients for whom the surgical resection encompassed the limits of the lesion on conventional MRI, histological data showed WM alterations (gliosis, axonal loss, abnormal cells). DTI often reveals WM abnormalities that are undetected on conventional MRI in patients with partial intractable epilepsy. (orig.)

  2. - LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography

    International Nuclear Information System (INIS)

    Behnes, Michael; Akin, Ibrahim; Sartorius, Benjamin; Fastner, Christian; El-Battrawy, Ibrahim; Borggrefe, Martin; Haubenreisser, Holger; Meyer, Mathias; Schoenberg, Stefan O.; Henzler, Thomas

    2016-01-01

    A standardized imaging proposal evaluating implanted left atrial appendage (LAA) occlusion devices by cardiac computed tomography angiography (cCTA) has never been investigated. cCTA datasets were acquired on a 3 rd generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. An interdisciplinary evaluation was performed by two interventional cardiologists and one radiologist on a 3D multi-planar workstation. A standardized multi-planar reconstruction algorithm was developed in order to assess relevant clinical aspects of implanted LAA occlusion devices being outlined within a pictorial essay. The following clinical aspects of implanted LAA occlusion devices were evaluated within the most appropriate cCTA multi-planar reconstruction: (1) topography to neighboring structures, (2) peri-device leaks, (3) coverage of LAA lobes, (4) indirect signs of neo-endothelialization. These are illustrated within concise CT imaging examples emphasizing the potential value of the proposed cCTA imaging algorithm: Starting from anatomical cCTA planes and stepwise angulation planes perpendicular to the base of the LAA devices generates an optimal LAA Occluder View for post-implantation Evaluation (LOVE). Aligned true axial, sagittal and coronal LOVE planes offer a standardized and detailed evaluation of LAA occlusion devices after percutaneous implantation. This pictorial essay presents a standardized imaging proposal by cCTA using multi-planar reconstructions that enables systematical follow-up and comparison of patients after LAA occlusion device implantation. The online version of this article (doi:10.1186/s12880-016-0127-y) contains supplementary material, which is available to authorized users

  3. Results of duct-occlud or nit-occlud device occlusion of patent ductus arteriousus

    International Nuclear Information System (INIS)

    Zhou Aiqing; Gao Wei; Yu Zhiqing; Li Feng; Wang Rongfa

    2003-01-01

    Objective: To evaluate the safety and efficacy of transcatheter patent ductus arteriosus (PDA) occlusion with the Duct-Occlud or Nit-Occlud device. Methods: All 68 patients with PDA (less than 4 mm minimum diameter) underwent percutaneous Duct-Occlud or Nit-Occlud coil occlusion in the Department of Cardiology, Shanghai Children's Medical Center between April 1997 and December 2001. The mean age was 5.5 ± 2.8 years (range, 1.5 to 12 years); mean weight was 13.9 ± 9.8 kg (range, 11.0 to 59.0 kg). The mean minimum diameter of the PDA was 1.63 ± 0.62 mm (range, 0.5-3.8 mm). Standard right and left retrograde heart catheterization were performed and followed by coil occlusion. A 4Fr or 5Fr catheter was used for coil deployment. Results: All patients had successful implantation of Duct-Occlud or Nit-Occlud devices. Patients follow-up evaluations were conducted at hospital discharge and after 3, 6 months and 1 year. At the discharge day and 1 year later, all patients showed complete PDA closure by color flow echo Doppler imaging. The hospitalization were only 5 days. At a median follow-up interval of 3.5 years (1 month to 4.6 years), there were no hemolysis, coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Conclusions: Because of the specifically designed coil with coincidental geometry of the ductus arteriosus, so transcatheter closure of PDA with the Duct-Occlud device is safe and effective for the closure of small-to-moderate-size patient ductus arteriosus. Utilization of Nit-Occlud is limited, but somewhat useful for large PDAs which is needed to be further investigated

  4. Results of duct-occlud or nit-occlud device occlusion of patent ductus arteriousus

    Energy Technology Data Exchange (ETDEWEB)

    Aiqing, Zhou; Wei, Gao; Zhiqing, Yu; Feng, Li; Rongfa, Wang [Shanghai Second Medical Univ., Shanghai (China). Shanghai Xinhua Hospital

    2003-10-01

    Objective: To evaluate the safety and efficacy of transcatheter patent ductus arteriosus (PDA) occlusion with the Duct-Occlud or Nit-Occlud device. Methods: All 68 patients with PDA (less than 4 mm minimum diameter) underwent percutaneous Duct-Occlud or Nit-Occlud coil occlusion in the Department of Cardiology, Shanghai Children's Medical Center between April 1997 and December 2001. The mean age was 5.5 {+-} 2.8 years (range, 1.5 to 12 years); mean weight was 13.9 {+-} 9.8 kg (range, 11.0 to 59.0 kg). The mean minimum diameter of the PDA was 1.63 {+-} 0.62 mm (range, 0.5-3.8 mm). Standard right and left retrograde heart catheterization were performed and followed by coil occlusion. A 4Fr or 5Fr catheter was used for coil deployment. Results: All patients had successful implantation of Duct-Occlud or Nit-Occlud devices. Patients follow-up evaluations were conducted at hospital discharge and after 3, 6 months and 1 year. At the discharge day and 1 year later, all patients showed complete PDA closure by color flow echo Doppler imaging. The hospitalization were only 5 days. At a median follow-up interval of 3.5 years (1 month to 4.6 years), there were no hemolysis, coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Conclusions: Because of the specifically designed coil with coincidental geometry of the ductus arteriosus, so transcatheter closure of PDA with the Duct-Occlud device is safe and effective for the closure of small-to-moderate-size patient ductus arteriosus. Utilization of Nit-Occlud is limited, but somewhat useful for large PDAs which is needed to be further investigated.

  5. Image Reconstruction For Bioluminescence Tomography From Partial Measurement

    OpenAIRE

    Jiang, M.; Zhou, T.; Cheng, J. T.; Cong, W. X.; Wang, Ge

    2007-01-01

    The bioluminescence tomography is a novel molecular imaging technology for small animal studies. Known reconstruction methods require the completely measured data on the external surface, although only partially measured data is available in practice. In this work, we formulate a mathematical model for BLT from partial data and generalize our previous results on the solution uniqueness to the partial data case. Then we extend two of our reconstruction methods for BLT to this case. The first m...

  6. Accuracy of MR imaging in partial tears of rotator cuff

    International Nuclear Information System (INIS)

    Eto, Masao; Ito, Nobuyuki; Tomonaga, Tadashi; Harada, Shin'ichi; Rabbi, M.E.; Iwasaki, Katsuro

    1997-01-01

    MRI is very useful for the diagnosis of the rotator cuff tear However. in case of partial tears it is sometimes controvertible. In this study, we studied the accuracy of MRI in the diagnosis of partial tears. 67 patients who underwent MRI investigation before operation were chosen for this study. There were 61 males and 6 females, ranging from 30 to 80 years (mean: 54.8 years at the time of operation). MRI was performed with 1.5T superconductive system with shoulder surface coil. MPGR T2-weighted images were performed in the coronal oblique and sagittal oblique planes. Complete tears were diagnosed when full thickness high intensity was observed in the rotator cuff, whereas with partial high intensity of the rotator cuff, was considered as partial tears. MRI demonstrated 77.8% sensitivity, 91.4% specificity and 89.6% accuracy in the diagnosis of partial tear. In 8 cases MRI had misinterpretation. In MPGR T2-weighted images, not only the partial tears but the degenerative changes also show high intensity of the rotator cuff. Therefore, it is difficult to differentiate and maybe this is the reason of misinterpretations of partial tears by MRI. MRI provided with useful pre-operative informations of partial tears of the rotator cuff. However, in few cases it is hard to differentiate for the degenerative changes of the rotator cuff. (author)

  7. Experimental evidence for partial spatial coherence in imaging Mueller polarimetry.

    Science.gov (United States)

    Ossikovski, Razvigor; Arteaga, Oriol; Yoo, Sang Hyuk; Garcia-Caurel, Enric; Hingerl, Kurt

    2017-11-15

    We demonstrate experimentally the validity of the partial spatial coherence formalism in Mueller polarimetry and show that, in a finite spatial resolution experiment, the measured response is obtained through convolving the theoretical one with the instrument function. The reported results are of primary importance for Mueller imaging systems.

  8. Robust reflective ghost imaging against different partially polarized thermal light

    Science.gov (United States)

    Li, Hong-Guo; Wang, Yan; Zhang, Rui-Xue; Zhang, De-Jian; Liu, Hong-Chao; Li, Zong-Guo; Xiong, Jun

    2018-03-01

    We theoretically study the influence of degree of polarization (DOP) of thermal light on the contrast-to-noise ratio (CNR) of the reflective ghost imaging (RGI), which is a novel and indirect imaging modality. An expression for the CNR of RGI with partially polarized thermal light is carefully derived, which suggests a weak dependence of CNR on the DOP, especially when the ratio of the object size to the speckle size of thermal light has a large value. Different from conventional imaging approaches, our work reveals that RGI is much more robust against the DOP of the light source, which thereby has advantages in practical applications, such as remote sensing.

  9. Single-Shot MR Spectroscopic Imaging with Partial Parallel Imaging

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2010-01-01

    An MR spectroscopic imaging (MRSI) pulse sequence based on Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) is introduced that measures 2-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3 T whole body scanner equipped with 12-channel array coil. Four-step interleaved phase encoding and 4-fold SENSE acceleration were used to encode a 16×16 spatial matrix with 390 Hz spectral width. Comparison with conventional PEPSI and PEPSI with 4-fold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of Inositol, Choline, Creatine and NAA in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement. PMID:19097245

  10. Imaging of Phase Objects using Partially Coherent Illumination

    Energy Technology Data Exchange (ETDEWEB)

    Ravizza, F. L. [Univ. of Arizona, Tucson, AZ (United States)

    2013-01-01

    Screening high-power laser optics for light intensifying phase objects that cause laserinduced damage on downstream optics is critical to sustaining laser operation. Identifying such flaws on large-apertures is quite challenging since they are relatively small and invisible to conventional inspection methods. A Linescan Phase Differential Imaging (LPDI) system was developed to rapidly identify these flaws on large-aperture optics within a single full-aperture dark-field image. We describe a two-step production phase object screening process consisting of LPDI mapping and image analysis, followed by high-resolution interferometry and propagation based evaluation of the downstream damage potential of identified flaws. An image simulation code capable of modeling the LPDI partially coherent illumination was used to optimize its phase object sensitivity.

  11. Hemolysis induced by PMIVSD occluder

    Directory of Open Access Journals (Sweden)

    D. Sheshagiri Rao

    2016-09-01

    Full Text Available Hemolysis related to occluder, prosthetic valve, and prosthetic ring used for mitral valve annuloplasty are not very unusual. However, hemolysis related to transcathetor closure of post-myocardial infarction ventricular septal defect (PMIVSD is infrequent. A close follow-up for spontaneous resolution with or without blood transfusion has been reported in a few cases. Occasionally, surgical retrieval is unavoidable or lifelong blood transfusion is required if surgery cannot be done because of higher risk. In this illustration, we have showed a close follow-up of a case of hemolysis induced by atrial septal occluder used for VSD closure after myocardial infarction. Despite successful device closure of PMIVSD which is difficult, a close watch is needed for complications like residual leak, device embolization, and hemolysis.

  12. Hemolysis induced by PMIVSD occluder.

    Science.gov (United States)

    Rao, D Sheshagiri; Barik, Ramachandra; Siva Prasad, Akula

    2016-09-01

    Hemolysis related to occluder, prosthetic valve, and prosthetic ring used for mitral valve annuloplasty are not very unusual. However, hemolysis related to transcathetor closure of post-myocardial infarction ventricular septal defect (PMIVSD) is infrequent. A close follow-up for spontaneous resolution with or without blood transfusion has been reported in a few cases. Occasionally, surgical retrieval is unavoidable or lifelong blood transfusion is required if surgery cannot be done because of higher risk. In this illustration, we have showed a close follow-up of a case of hemolysis induced by atrial septal occluder used for VSD closure after myocardial infarction. Despite successful device closure of PMIVSD which is difficult, a close watch is needed for complications like residual leak, device embolization, and hemolysis. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  13. Imaging polarimetry of forest canopies: how the azimuth direction of the sun, occluded by vegetation, can be assessed from the polarization pattern of the sunlit foliage

    Science.gov (United States)

    Hegedüs, Ramón; Barta, András; Bernáth, Balázs; Benno Meyer-Rochow, Victor; Horváth, Gábor

    2007-08-01

    Radiance, color, and polarization of the light in forests combine to create complex optical patterns. Earlier sporadic polarimetric studies in forests were limited by the narrow fields of view of the polarimeters used in such studies. Since polarization patterns in the entire upper hemisphere of the visual environment of forests could be important for forest-inhabiting animals that make use of linearly polarized light for orientation, we measured 180° field-of-view polarization distributions in Finnish forests. From a hot air balloon we also measured the polarization patterns of Hungarian grasslands lit by the rising sun. We found that the pattern of the angle of polarization α of sunlit grasslands and sunlit tree canopies was qualitatively the same as that of the sky. We show here that contrary to an earlier assumption, the α-pattern characteristic of the sky always remains visible underneath overhead vegetation, independently of the solar elevation and the sky conditions (clear or partly cloudy with visible sun's disc), provided the foliage is sunlit and not only when large patches of the clear sky are visible through the vegetation. Since the mirror symmetry axis of the α-pattern of the sunlit foliage is the solar-antisolar meridian, the azimuth direction of the sun, occluded by vegetation, can be assessed in forests from this polarization pattern. Possible consequences of this robust polarization feature of the optical environment in forests are briefly discussed with regard to polarization-based animal navigation.

  14. The characteristics of SPECT images in childhood benign partial epilepsy

    International Nuclear Information System (INIS)

    Jia Shaowei; Liao Jianxiang; Liu Xiaoyan; Zheng Xiyuan; Qin Jiong; Pan Zhongyun; Zuo Qihua

    1998-01-01

    Purpose: To investigate childhood benign partial epilepsy (BPE) with SPECT. Methods: Double SPECT imaging was performed on 21 cases of BPE at the stage of wake (interval spike discharge) and sleep (spike discharge), under EEG monitoring. The transverse images were reconstructed after digital image subtraction. The quantitative analysis was conducted with brain flow change rate (BFCR) % mathematical model. Results: EEG monitoring demonstrated approximately normal background of 21 cases of BPE during the stage of wake, and spike discharge frequency markedly increased during the stage of sleep, 117 foci were showed by SPeCT in cases of BPE, and the average was 5.6 +- 1.6 foci/case. The characteristics of SPECT transverse images were 1) multiple foci of mirror, 2) mostly seen in Rolandic region, 3) circular symbol, 4) the radioactivity in foci decreased during the stage of wake (interval spike discharge) and increased during the stage of sleep (spike discharge). The concordance of SPECT and EEG was 93.1% (109/117 foci). The BFCR% of all epileptogenic foci exceeded normal limit (99% confidence interval). There was no correlation between the spike discharge frequency and BFCR% (r = 0.45, P>0.05). Conclusions: Regional cerebral blood flow and function were abnormal during the epileptogenic foci were discharging abnormally in BPE

  15. Partial flip angle spin-echo imaging to obtain T1 weighted images with electrocardiographic gating

    International Nuclear Information System (INIS)

    Kawamitsu, Hideaki; Sugimura, Kazuro; Kasai, Toshifumi; Kimino, Katsuji

    1993-01-01

    ECG-gated spin-echo (SE) imaging can reduce physiologic motion artifact. However, it does not provide strong T 1 -weighted images, because the repetition time (TR) depends on heart rate (HR). For odd-echo SE imaging, T 1 contrast can be maximized by using a smaller flip angle (FA) of initial excitation RF pulses. We investigated the usefulness of partial FA SE imaging in order to obtain more T 1 -dependent contrast with ECG gating and determined the optimal FA at each heart rate. In computer simulation and phantom study, the predicted image contrast and signal-to-noise ratio (SNR) obtained for each FA (0∼180deg) and each HR (55∼90 beats per minute (bpm)) were compared with those obtained with conventional T 1 -weighted SE imaging (TR=500 ms, TE=20 ms, FA=90deg). The optimal FA was decreased by reducing HR. The FA needed to obtain T 1 -dependent contrast identical to that with T 1 -weighted SE imaging was 43deg at a HR of 65 bpm, 53deg at 70 bpm, 60deg at 75 bpm. This predicted FA were in excellent agreement with that obtained with clinical evaluation. The predicted SNR was decreased by reducing FA. The SNR of partial FA SE imaging at HR of 65 bpm (FA=43deg) was 80% of that with conventional T 1 -weighted SE imaging. However, this imaging method presented no marked clinical problem. ECG-gated partial FA SE imaging provides better T 1 -dependent contrast than conventional ECG-gated SE imaging, especially for Gd-DTPA enhanced imaging. (author)

  16. Technical Note: Deformable image registration on partially matched images for radiotherapy applications

    International Nuclear Information System (INIS)

    Yang Deshan; Goddu, S. Murty; Lu Wei; Pechenaya, Olga L.; Wu Yu; Deasy, Joseph O.; El Naqa, Issam; Low, Daniel A.

    2010-01-01

    In radiation therapy applications, deformable image registrations (DIRs) are often carried out between two images that only partially match. Image mismatching could present as superior-inferior coverage differences, field-of-view (FOV) cutoffs, or motion crossing the image boundaries. In this study, the authors propose a method to improve the existing DIR algorithms so that DIR can be carried out in such situations. The basic idea is to extend the image volumes and define the extension voxels (outside the FOV or outside the original image volume) as NaN (not-a-number) values that are transparent to all floating-point computations in the DIR algorithms. Registrations are then carried out with one additional rule that NaN voxels can match any voxels. In this way, the matched sections of the images are registered properly, and the mismatched sections of the images are registered to NaN voxels. This method makes it possible to perform DIR on partially matched images that otherwise are difficult to register. It may also improve DIR accuracy, especially near or in the mismatched image regions.

  17. A single-image method of aberration retrieval for imaging systems under partially coherent illumination

    International Nuclear Information System (INIS)

    Xu, Shuang; Liu, Shiyuan; Zhang, Chuanwei; Wei, Haiqing

    2014-01-01

    We propose a method for retrieving small lens aberrations in optical imaging systems under partially coherent illumination, which only requires to measure one single defocused image of intensity. By deriving a linear theory of imaging systems, we obtain a generalized formulation of aberration sensitivity in a matrix form, which provides a set of analytic kernels that relate the measured intensity distribution directly to the unknown Zernike coefficients. Sensitivity analysis is performed and test patterns are optimized to ensure well-posedness of the inverse problem. Optical lithography simulations have validated the theoretical derivation and confirmed its simplicity and superior performance in retrieving small lens aberrations. (fast track communication)

  18. Functional MR imaging in the patients with complex partial seizures

    International Nuclear Information System (INIS)

    Chung, Jin Il; Chang, Kee Hyun; Song, In Chan; Goo, Jin Mo; Chung, Chun Kee; Lee, Sang Kun; Kim, Hong Dae; Han, Moon Hee; Kim, Sam Soo

    1999-01-01

    To evaluate the clinical usefulness of functional MR imaging (fMRI) for localization of the cerebral motor and sensory cortices and language center in patients with complex partial seizure. A total of 47 fMRIs were obtained in 14 patients (M:F = 9:5; age 15-50 years; 13 right handed and 1 ambidextrous) with complex partial seizure (6 temporal lobe epilepsy, 6 frontal lobe epilepsy, 1 occipitotemporal lobe epilepsy, 1 hemispheric epilepsy). Conventional MR imaging revealed no abnormality in four patients, localized cerebral atrophy in one, hippocampal sclerosis in four, and benign neoplasm in the remaining five. fMRI was performed on a 1.5 T MR scanner (GE Signa Horizon) using gradient-echo singleshot EPI. Nineteen fMRIs were obtained in eight patients who performed the language task, 16 fMRIs in ten who performed the motor task and 12 fMRIs in ten who performed the somatosensory task. The activation task consisted of three language tasks (silent picture naming , word generation from a character, categorical word generation), motor tasks (opposition of thumb and index finger for hand/dorsifexion or extension for foot), and sensory tasks (passive tactile stimulation of hand or foot using a toothbrush). The data were analyzed using z-score (p<0.05), clustering, and cross-correlation analysis based upon homemade software, IDL 5.1. The success rate for obtaining meaningful fMRI was evaluated and activated regions were assessed on the basis of each fMRI obtained during, language, motor, and somatosensory tasks. fMRI findings were compared with those of the Wada test (n = 7) for language lateralization and with invasive cortical mapping (n = 3) for the localization of eloquent cerebral cortex, especially around the central sulcus. The overall success rate of fMRI was 79 % (37/47); success rates of fMRI with language, sensory, and motor task were 89% (17/19), 83 % (10/12), and 63 % (10/16), respectively. Areas activated during language tasks (n=17) included the

  19. Self-imaging of partially coherent light in graded-index media.

    Science.gov (United States)

    Ponomarenko, Sergey A

    2015-02-15

    We demonstrate that partially coherent light beams of arbitrary intensity and spectral degree of coherence profiles can self-image in linear graded-index media. The results can be applicable to imaging with noisy spatial or temporal light sources.

  20. Forming positive-negative images using conditioned partial measurements from reference arm in ghost imaging.

    Science.gov (United States)

    Wen, Jianming

    2012-09-01

    A recent thermal ghost imaging experiment implemented in Wu's group [Chin. Phys. Lett. 279, 074216 (2012)] showed that both positive and negative images can be constructed by applying a novel algorithm. This algorithm allows us to form the images with the use of partial measurements from the reference arm (even which never passes through the object), conditioned on the object arm. In this paper, we present a simple theory that explains the experimental observation and provides an in-depth understanding of conventional ghost imaging. In particular, we theoretically show that the visibility of formed images through such an algorithm is not bounded by the standard value 1/3. In fact, it can ideally grow up to unity (with reduced imaging quality). Thus, the algorithm described here not only offers an alternative way to decode spatial correlation of thermal light, but also mimics a "bandpass filter" to remove the constant background such that the visibility or imaging contrast is improved. We further show that conditioned on one still object present in the test arm, it is possible to construct the object's image by sampling the available reference data.

  1. Renal hemodynamics and oxygenation in transient renal artery occluded rats evaluated with iron-oxide particles and oxygenation-sensitive imaging

    International Nuclear Information System (INIS)

    Pedersen, Michael; Aarhus Univ.; Univ. Victor Segalen Bordeaux 2; Laustsen, Christoffer; Perot, Vincent; Grenier, Nicolas; Basseau, Fabrice; Moonen, Chrit

    2010-01-01

    Mild or severe renal arterial occlusion is a phenomenon occasionally observed in daily clinical practice, potentially leading to renal ischemia and a general impairment of renal function. Secondly, closing the blood flow to the kidneys can also occur during kidney transplantation procedures. However, the exact physiological effects of these conditions on renal blood perfusion as well as the renal oxygen handling are poorly understood. The objectives of this study were therefore to measure the lateral changes of renal blood perfusion in rats subjected to transient unilateral arterial occlusion (RAS), and in addition, to measure the consequences on the intrarenal oxygenation. Experimental studies were performed using sixteen adolescent rats. The left renal artery was exposed through a flank incision and acute RAS for 45 min was achieved by placing a ligature around the renal artery. MRI was performed 3 days after the surgical procedure, where a blood oxygenation sensitive sequence (BOLD MRI) was performed, followed by a perfusion-weighted imaging sequence using a single bolus of the iron-oxide nanoparticle Sinerem. The renal oxygenation of blood was indirectly measured by the BOLD-parameter R2 * , and perfusion measures include relative renal blood flow, relative renal blood volume and mean transit time. Histopathologic changes through the outer stripe of the outer medulla showing typical histopathologic findings of ischemia. This study demonstrated that rats with transient renal arterial stenosis (for 45 min) showed a reduction in intrarenal oxygenation and intrarenal blood flow three days after the surgical procedure. A decreased R2 * was measured within the ipsilateral medulla in parallel with a decreased medullary blood flow, is probably related to a lower reabsorption load within the ipsilateral kidney. MRI may therefore be a promising tool in long-term evaluation of RAS. (orig.)

  2. Renal hemodynamics and oxygenation in transient renal artery occluded rats evaluated with iron-oxide particles and oxygenation-sensitive imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Michael [Aarhus Univ. Hospital (Denmark). MR Research Centre; Aarhus Univ. (Denmark). Inst. of Experimental Clinical Medicine; Univ. Victor Segalen Bordeaux 2 (France). Lab. Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231; Laustsen, Christoffer [Aarhus Univ. Hospital (Denmark). MR Research Centre; Perot, Vincent; Grenier, Nicolas [Hopital Pellegrin, CHU Bordeaux (France). Service d' Imagerie Diagnostique et Therapeutique de l' Adulte; Basseau, Fabrice; Moonen, Chrit [Univ. Victor Segalen Bordeaux 2 (France). Lab. Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231

    2010-07-01

    Mild or severe renal arterial occlusion is a phenomenon occasionally observed in daily clinical practice, potentially leading to renal ischemia and a general impairment of renal function. Secondly, closing the blood flow to the kidneys can also occur during kidney transplantation procedures. However, the exact physiological effects of these conditions on renal blood perfusion as well as the renal oxygen handling are poorly understood. The objectives of this study were therefore to measure the lateral changes of renal blood perfusion in rats subjected to transient unilateral arterial occlusion (RAS), and in addition, to measure the consequences on the intrarenal oxygenation. Experimental studies were performed using sixteen adolescent rats. The left renal artery was exposed through a flank incision and acute RAS for 45 min was achieved by placing a ligature around the renal artery. MRI was performed 3 days after the surgical procedure, where a blood oxygenation sensitive sequence (BOLD MRI) was performed, followed by a perfusion-weighted imaging sequence using a single bolus of the iron-oxide nanoparticle Sinerem. The renal oxygenation of blood was indirectly measured by the BOLD-parameter R2{sup *}, and perfusion measures include relative renal blood flow, relative renal blood volume and mean transit time. Histopathologic changes through the outer stripe of the outer medulla showing typical histopathologic findings of ischemia. This study demonstrated that rats with transient renal arterial stenosis (for 45 min) showed a reduction in intrarenal oxygenation and intrarenal blood flow three days after the surgical procedure. A decreased R2{sup *} was measured within the ipsilateral medulla in parallel with a decreased medullary blood flow, is probably related to a lower reabsorption load within the ipsilateral kidney. MRI may therefore be a promising tool in long-term evaluation of RAS. (orig.)

  3. Fast MR image reconstruction for partially parallel imaging with arbitrary k-space trajectories.

    Science.gov (United States)

    Ye, Xiaojing; Chen, Yunmei; Lin, Wei; Huang, Feng

    2011-03-01

    Both acquisition and reconstruction speed are crucial for magnetic resonance (MR) imaging in clinical applications. In this paper, we present a fast reconstruction algorithm for SENSE in partially parallel MR imaging with arbitrary k-space trajectories. The proposed method is a combination of variable splitting, the classical penalty technique and the optimal gradient method. Variable splitting and the penalty technique reformulate the SENSE model with sparsity regularization as an unconstrained minimization problem, which can be solved by alternating two simple minimizations: One is the total variation and wavelet based denoising that can be quickly solved by several recent numerical methods, whereas the other one involves a linear inversion which is solved by the optimal first order gradient method in our algorithm to significantly improve the performance. Comparisons with several recent parallel imaging algorithms indicate that the proposed method significantly improves the computation efficiency and achieves state-of-the-art reconstruction quality.

  4. A simplified approach to merging partial plane image

    Directory of Open Access Journals (Sweden)

    Mária Kruláková

    2012-12-01

    Full Text Available This paper introduces a method of image recognition based on the gradual generating and analysis of data structure consistingof the 2D space using the difference from the row and column vectors’ sums as an application of the linear algebra. The result ofthe data processing is a graphical interpretation of the measure of the similarity of the generated results of overlapping of 2 images.Maximal measure of the similarity is a measure for image registration. The study result is to create a list of the images order, in which one follows the other, included in the non-registered set of images that can be used for the final image-stitching

  5. New partially parallel acquisition technique in cerebral imaging: preliminary findings

    International Nuclear Information System (INIS)

    Tintera, Jaroslav; Gawehn, Joachim; Bauermann, Thomas; Vucurevic, Goran; Stoeter, Peter

    2004-01-01

    In MRI applications where short acquisition time is necessary, the increase of acquisition speed is often at the expense of image resolution and SNR. In such cases, the newly developed parallel acquisition techniques could provide images without mentioned limitations and in reasonably shortened measurement time. A newly designed eight-channel head coil array (i-PAT coil) allowing for parallel acquisition of independently reconstructed images (GRAPPA mode) has been tested for its applicability in neuroradiology. Image homogeneity was tested in standard phantom and healthy volunteers. BOLD signal changes were studied in a group of six volunteers using finger tapping stimulation. Phantom studies revealed an important drop of signal even after the use of a normalization filter in the center of the image and an important increase of artifact power with reduction of measurement time strongly depending on the combination of acceleration parameters. The additional application of a parallel acquisition technique such as GRAPPA decreases measurement time in the range of about 30%, but further reduction is often possible only at the expense of SNR. This technique performs best in conditions in which imaging speed is important, such as CE MRA, but time resolution still does not allow the acquisition of angiograms separating the arterial and venous phase. Significantly larger areas of BOLD activation were found using the i-PAT coil compared to the standard head coil. Being an eight-channel surface coil array, peripheral cortical structures profit from high SNR as high-resolution imaging of small cortical dysplasias and functional activation of cortical areas imaged by BOLD contrast. In BOLD contrast imaging, susceptibility artifacts are reduced, but only if an appropriate combination of acceleration parameters is used. (orig.)

  6. New partially parallel acquisition technique in cerebral imaging: preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Tintera, Jaroslav [Institute for Clinical and Experimental Medicine, Prague (Czech Republic); Gawehn, Joachim; Bauermann, Thomas; Vucurevic, Goran; Stoeter, Peter [University Clinic Mainz, Institute of Neuroradiology, Mainz (Germany)

    2004-12-01

    In MRI applications where short acquisition time is necessary, the increase of acquisition speed is often at the expense of image resolution and SNR. In such cases, the newly developed parallel acquisition techniques could provide images without mentioned limitations and in reasonably shortened measurement time. A newly designed eight-channel head coil array (i-PAT coil) allowing for parallel acquisition of independently reconstructed images (GRAPPA mode) has been tested for its applicability in neuroradiology. Image homogeneity was tested in standard phantom and healthy volunteers. BOLD signal changes were studied in a group of six volunteers using finger tapping stimulation. Phantom studies revealed an important drop of signal even after the use of a normalization filter in the center of the image and an important increase of artifact power with reduction of measurement time strongly depending on the combination of acceleration parameters. The additional application of a parallel acquisition technique such as GRAPPA decreases measurement time in the range of about 30%, but further reduction is often possible only at the expense of SNR. This technique performs best in conditions in which imaging speed is important, such as CE MRA, but time resolution still does not allow the acquisition of angiograms separating the arterial and venous phase. Significantly larger areas of BOLD activation were found using the i-PAT coil compared to the standard head coil. Being an eight-channel surface coil array, peripheral cortical structures profit from high SNR as high-resolution imaging of small cortical dysplasias and functional activation of cortical areas imaged by BOLD contrast. In BOLD contrast imaging, susceptibility artifacts are reduced, but only if an appropriate combination of acceleration parameters is used. (orig.)

  7. Partial segmental thrombosis of the corpus cavernosum: imaging findings.

    Science.gov (United States)

    Moya-Sánchez, E; Medina-Benítez, A; Medina-Salas, V; Fernández-Navarro, L

    2018-03-05

    Partial segmental thrombosis of the corpus cavernosum is an unusual clinical condition of unknown origin that mainly affects young males, whose characteristic presentation is the appearance of unexplained perineal pain associated with a palpable perineal mass. This entity consists of thrombosis in the perineal portion of the corpus cavernosum, usually unilateral and it is associated with underlying malignant pathologies and predisposing factors such as microtrauma. After the adequate adherence to conservative treatment, the appearance of complications such as erectile dysfunction is very uncommon. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. T-junctions and perceived slant of partially occluded surfaces.

    Science.gov (United States)

    Grove, Philip M; Ono, Hiroshi; Kaneko, Hirohiko

    2003-01-01

    Häkkinen and Nyman (1997 Perception 26 29-38) reported that perceived slant is reduced when occlusion is a possible interpretation for the visual system. We present data from three experiments that confirm and expand on their finding. Our stimuli consisted of four types of stereograms depicting white central rectangles flanked on either side by two grey rectangles. The central white rectangles varied in height, thus manipulating the polarity of the T-junction information between the central and flanking rectangles. Perceived slant was smallest or not apparent when T-junction information indicated the central rectangles were nearer than the flanking rectangles and greatest when T-junction information indicated a farther central rectangle. Slant estimates for a stimulus containing a subjective pacmen-induced central rectangle were biased towards a depth step when an occlusion interpretation was possible.

  9. Hereditary spherocytosis and partial splenectomy in children: review of surgical technique and the role of imaging

    International Nuclear Information System (INIS)

    Hollingsworth, Caroline L.; Rice, Henry E.

    2010-01-01

    The risks associated with total splenectomy, including overwhelming postsplenectomy infection, have led to an interest in the use of partial splenectomy as an alternative surgical option for children with congenital hemolytic anemias and hypersplenism. Partial splenectomy, a procedure designed to remove enough spleen to improve anemia and avoid complications of splenic sequestration while preserving splenic function, has shown promise in children. Radiologic imaging is essential for the preoperative evaluation and postoperative care for children undergoing partial splenectomy and offers a broad range of critical clinical information essential for care of these complex children. It is imperative for radiologists involved in the care of these children to be familiar with the surgical technique and imaging options for these procedures. This article reviews the surgical technique as well as the current status of various diagnostic imaging options used for children undergoing partial splenectomy, highlighting technical aspects and specific clinical information obtained by each modality. (orig.)

  10. Hereditary spherocytosis and partial splenectomy in children: review of surgical technique and the role of imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hollingsworth, Caroline L. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States); Rice, Henry E. [Duke University Medical Center, Department of Surgery, Durham, NC (United States)

    2010-07-15

    The risks associated with total splenectomy, including overwhelming postsplenectomy infection, have led to an interest in the use of partial splenectomy as an alternative surgical option for children with congenital hemolytic anemias and hypersplenism. Partial splenectomy, a procedure designed to remove enough spleen to improve anemia and avoid complications of splenic sequestration while preserving splenic function, has shown promise in children. Radiologic imaging is essential for the preoperative evaluation and postoperative care for children undergoing partial splenectomy and offers a broad range of critical clinical information essential for care of these complex children. It is imperative for radiologists involved in the care of these children to be familiar with the surgical technique and imaging options for these procedures. This article reviews the surgical technique as well as the current status of various diagnostic imaging options used for children undergoing partial splenectomy, highlighting technical aspects and specific clinical information obtained by each modality. (orig.)

  11. Determination of mango fruit from binary image using randomized Hough transform

    Science.gov (United States)

    Rizon, Mohamed; Najihah Yusri, Nurul Ain; Abdul Kadir, Mohd Fadzil; bin Mamat, Abd. Rasid; Abd Aziz, Azim Zaliha; Nanaa, Kutiba

    2015-12-01

    A method of detecting mango fruit from RGB input image is proposed in this research. From the input image, the image is processed to obtain the binary image using the texture analysis and morphological operations (dilation and erosion). Later, the Randomized Hough Transform (RHT) method is used to find the best ellipse fits to each binary region. By using the texture analysis, the system can detect the mango fruit that is partially overlapped with each other and mango fruit that is partially occluded by the leaves. The combination of texture analysis and morphological operator can isolate the partially overlapped fruit and fruit that are partially occluded by leaves. The parameters derived from RHT method was used to calculate the center of the ellipse. The center of the ellipse acts as the gripping point for the fruit picking robot. As the results, the rate of detection was up to 95% for fruit that is partially overlapped and partially covered by leaves.

  12. Image denoising using new pixon representation based on fuzzy filtering and partial differential equations

    DEFF Research Database (Denmark)

    Nadernejad, Ehsan; Nikpour, Mohsen

    2012-01-01

    In this paper, we have proposed two extensions to pixon-based image modeling. The first one is using bicubic interpolation instead of bilinear interpolation and the second one is using fuzzy filtering method, aiming to improve the quality of the pixonal image. Finally, partial differential...

  13. Large-Scale Partial-Duplicate Image Retrieval and Its Applications

    Science.gov (United States)

    2016-04-23

    tree based image retrieval , a semantic-aware co-indexing algorithm is proposed to jointly embed two strong cues into the inverted indexes: 1) local...based image retrieval , a semantic-aware co-indexing algorithm is proposed to jointly embed two strong cues into the inverted indexes: 1) local...Distribution Unlimited UU UU UU UU 23-04-2016 23-Jan-2012 22-Jan-2016 Final Report: Large-Scale Partial-Duplicate Image Retrieval and Its Applications

  14. Defocusing effects of lensless ghost imaging and ghost diffraction with partially coherent sources

    Science.gov (United States)

    Zhou, Shuang-Xi; Sheng, Wei; Bi, Yu-Bo; Luo, Chun-Ling

    2018-04-01

    The defocusing effect is inevitable and degrades the image quality in the conventional optical imaging process significantly due to the close confinement of the imaging lens. Based on classical optical coherent theory and linear algebra, we develop a unified formula to describe the defocusing effects of both lensless ghost imaging (LGI) and lensless ghost diffraction (LGD) systems with a partially coherent source. Numerical examples are given to illustrate the influence of defocusing length on the quality of LGI and LGD. We find that the defocusing effects of the test and reference paths in the LGI or LGD systems are entirely different, while the LGD system is more robust against defocusing than the LGI system. Specifically, we find that the imaging process for LGD systems can be viewed as pinhole imaging, which may find applications in ultra-short-wave band imaging without imaging lenses, e.g. x-ray diffraction and γ-ray imaging.

  15. Partial fourier and parallel MR image reconstruction with integrated gradient nonlinearity correction.

    Science.gov (United States)

    Tao, Shengzhen; Trzasko, Joshua D; Shu, Yunhong; Weavers, Paul T; Huston, John; Gray, Erin M; Bernstein, Matt A

    2016-06-01

    To describe how integrated gradient nonlinearity (GNL) correction can be used within noniterative partial Fourier (homodyne) and parallel (SENSE and GRAPPA) MR image reconstruction strategies, and demonstrate that performing GNL correction during, rather than after, these routines mitigates the image blurring and resolution loss caused by postreconstruction image domain based GNL correction. Starting from partial Fourier and parallel magnetic resonance imaging signal models that explicitly account for GNL, noniterative image reconstruction strategies for each accelerated acquisition technique are derived under the same core mathematical assumptions as their standard counterparts. A series of phantom and in vivo experiments on retrospectively undersampled data were performed to investigate the spatial resolution benefit of integrated GNL correction over conventional postreconstruction correction. Phantom and in vivo results demonstrate that the integrated GNL correction reduces the image blurring introduced by the conventional GNL correction, while still correcting GNL-induced coarse-scale geometrical distortion. Images generated from undersampled data using the proposed integrated GNL strategies offer superior depiction of fine image detail, for example, phantom resolution inserts and anatomical tissue boundaries. Noniterative partial Fourier and parallel imaging reconstruction methods with integrated GNL correction reduce the resolution loss that occurs during conventional postreconstruction GNL correction while preserving the computational efficiency of standard reconstruction techniques. Magn Reson Med 75:2534-2544, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  16. An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Willis, David J.; Kron, Tomas; Chua, Boon

    2011-01-01

    The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imaging was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.

  17. Partially converted stereoscopic images and the effects on visual attention and memory

    Science.gov (United States)

    Kim, Sanghyun; Morikawa, Hiroyuki; Mitsuya, Reiko; Kawai, Takashi; Watanabe, Katsumi

    2015-03-01

    This study contained two experimental examinations of the cognitive activities such as visual attention and memory in viewing stereoscopic (3D) images. For this study, partially converted 3D images were used with binocular parallax added to a specific region of the image. In Experiment 1, change blindness was used as a presented stimulus. The visual attention and impact on memory were investigated by measuring the response time to accomplish the given task. In the change blindness task, an 80 ms blank was intersected between the original and altered images, and the two images were presented alternatingly for 240 ms each. Subjects were asked to temporarily memorize the two switching images and to compare them, visually recognizing the difference between the two. The stimuli for four conditions (2D, 3D, Partially converted 3D, distracted partially converted 3D) were randomly displayed for 20 subjects. The results of Experiment 1 showed that partially converted 3D images tend to attract visual attention and are prone to remain in viewer's memory in the area where moderate negative parallax has been added. In order to examine the impact of a dynamic binocular disparity on partially converted 3D images, an evaluation experiment was conducted that applied learning, distraction, and recognition tasks for 33 subjects. The learning task involved memorizing the location of cells in a 5 × 5 matrix pattern using two different colors. Two cells were positioned with alternating colors, and one of the gray cells was moved up, down, left, or right by one cell width. Experimental conditions was set as a partially converted 3D condition in which a gray cell moved diagonally for a certain period of time with a dynamic binocular disparity added, a 3D condition in which binocular disparity was added to all gray cells, and a 2D condition. The correct response rates for recognition of each task after the distraction task were compared. The results of Experiment 2 showed that the correct

  18. In vivo near real time imaging of oxygen partial pressures in the glass catfish (Kryptopterus bichirris)

    DEFF Research Database (Denmark)

    Steffensen, John Fleng

    2012-01-01

    of the transparent glass catfish (Kryptopterus bichirris), it is possible to measure near realtime oxygen partial pressure in vivo. We used a commercially-available digital single-lens reflex camera mounted with an optical long pass filter (II = 490 nm) and excited the phosphorescent dye in the microspheres inside...... the fish with externally-mounted blue light emitting diodes (lip = 470 nm) to image the oxygen partial pressure. This method makes it possible to investigate oxygen partial pressures in the vascular system and different tissues of fish without having to insert any probes into the animal. After injection...

  19. Transcatheter closure of ventricular septal defect with Occlutech Duct Occluder.

    Science.gov (United States)

    Atik-Ugan, Sezen; Saltik, Irfan Levent

    2018-04-01

    Patent ductus arteriosus occluders are used for transcatheter closure of ventricular septal defects, as well as for closure of patent ductus arteriosus. The Occlutech Duct Occluder is a newly introduced device for transcatheter closure of patent ductus arteriosus. Here, we present a case in which the Occlutech Duct Occluder was successfully used on a patient for the closure of a perimembraneous ventricular septal defect.

  20. [Evaluation of Image Quality of Readout Segmented EPI with Readout Partial Fourier Technique].

    Science.gov (United States)

    Yoshimura, Yuuki; Suzuki, Daisuke; Miyahara, Kanae

    Readout segmented EPI (readout segmentation of long variable echo-trains: RESOLVE) segmented k-space in the readout direction. By using the partial Fourier method in the readout direction, the imaging time was shortened. However, the influence on image quality due to insufficient data sampling is concerned. The setting of the partial Fourier method in the readout direction in each segment was changed. Then, we examined signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and distortion ratio for changes in image quality due to differences in data sampling. As the number of sampling segments decreased, SNR and CNR showed a low value. In addition, the distortion ratio did not change. The image quality of minimum sampling segments is greatly different from full data sampling, and caution is required when using it.

  1. Optimal transformation for correcting partial volume averaging effects in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Soltanian-Zadeh, H.; Windham, J.P.; Yagle, A.E.

    1993-01-01

    Segmentation of a feature of interest while correcting for partial volume averaging effects is a major tool for identification of hidden abnormalities, fast and accurate volume calculation, and three-dimensional visualization in the field of magnetic resonance imaging (MRI). The authors present the optimal transformation for simultaneous segmentation of a desired feature and correction of partial volume averaging effects, while maximizing the signal-to-noise ratio (SNR) of the desired feature. It is proved that correction of partial volume averaging effects requires the removal of the interfering features from the scene. It is also proved that correction of partial volume averaging effects can be achieved merely by a linear transformation. It is finally shown that the optimal transformation matrix is easily obtained using the Gram-Schmidt orthogonalization procedure, which is numerically stable. Applications of the technique to MRI simulation, phantom, and brain images are shown. They show that in all cases the desired feature is segmented from the interfering features and partial volume information is visualized in the resulting transformed images

  2. Probabilistic Characterization of Partial Volume Effects in Imaging of Rectangular Objects

    Energy Technology Data Exchange (ETDEWEB)

    Bulaevskaya, V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-05-06

    In imaging, a partial volume effect refers to the problem that arises when the system resolution is low relative to the size of the object being imaged [1, 2]. In this setting, it is likely that most voxels occupied by the object are only partially covered, and that the fraction covered in each voxel is low. This makes the problem of object detection and image segmentation very difficult because the algorithms designed for these purposes rely on pixel summary statistics. If the area covered by the object is very low in relatively many of the total number of the voxels the object occupies, these summary statistics may not reach the thresholds required to detect this object. It is thus important to understand the extent of partial volume effect for a given object size and resolution. This technical report focuses on rectangular objects and derives the probability distributions for three quantities for such objects: 1) the number of fully covered voxels, 2) the number of partially covered voxels, and 3) the fractions of the total volume covered in the partially covered voxels. The derivations are first shown for 2-D settings and are then extended to 3-D settings.

  3. Image/patient registration from (partial) projection data by the Fourier phase matching method

    International Nuclear Information System (INIS)

    Weiguo Lu; You, J.

    1999-01-01

    A technique for 2D or 3D image/patient registration, PFPM (projection based Fourier phase matching method), is proposed. This technique provides image/patient registration directly from sequential tomographic projection data. The method can also deal with image files by generating 2D Radon transforms slice by slice. The registration in projection space is done by calculating a Fourier invariant (FI) descriptor for each one-dimensional projection datum, and then registering the FI descriptor by the Fourier phase matching (FPM) method. The algorithm has been tested on both synthetic and experimental data. When dealing with translated, rotated and uniformly scaled 2D image registration, the performance of the PFPM method is comparable to that of the IFPM (image based Fourier phase matching) method in robustness, efficiency, insensitivity to the offset between images, and registration time. The advantages of the former are that subpixel resolution is feasible, and it is more insensitive to image noise due to the averaging effect of the projection acquisition. Furthermore, the PFPM method offers the ability to generalize to 3D image/patient registration and to register partial projection data. By applying patient registration directly from tomographic projection data, image reconstruction is not needed in the therapy set-up verification, thus reducing computational time and artefacts. In addition, real time registration is feasible. Registration from partial projection data meets the geometry and dose requirements in many application cases and makes dynamic set-up verification possible in tomotherapy. (author)

  4. Catching what we can't see: manual interception of occluded fly-ball trajectories.

    Science.gov (United States)

    Bosco, Gianfranco; Delle Monache, Sergio; Lacquaniti, Francesco

    2012-01-01

    Control of interceptive actions may involve fine interplay between feedback-based and predictive mechanisms. These processes rely heavily on target motion information available when the target is visible. However, short-term visual memory signals as well as implicit knowledge about the environment may also contribute to elaborate a predictive representation of the target trajectory, especially when visual feedback is partially unavailable because other objects occlude the visual target. To determine how different processes and information sources are integrated in the control of the interceptive action, we manipulated a computer-generated visual environment representing a baseball game. Twenty-four subjects intercepted fly-ball trajectories by moving a mouse cursor and by indicating the interception with a button press. In two separate sessions, fly-ball trajectories were either fully visible or occluded for 750, 1000 or 1250 ms before ball landing. Natural ball motion was perturbed during the descending trajectory with effects of either weightlessness (0 g) or increased gravity (2 g) at times such that, for occluded trajectories, 500 ms of perturbed motion were visible before ball disappearance. To examine the contribution of previous visual experience with the perturbed trajectories to the interception of invisible targets, the order of visible and occluded sessions was permuted among subjects. Under these experimental conditions, we showed that, with fully visible targets, subjects combined servo-control and predictive strategies. Instead, when intercepting occluded targets, subjects relied mostly on predictive mechanisms based, however, on different type of information depending on previous visual experience. In fact, subjects without prior experience of the perturbed trajectories showed interceptive errors consistent with predictive estimates of the ball trajectory based on a-priori knowledge of gravity. Conversely, the interceptive responses of subjects

  5. Catching what we can't see: manual interception of occluded fly-ball trajectories.

    Directory of Open Access Journals (Sweden)

    Gianfranco Bosco

    Full Text Available Control of interceptive actions may involve fine interplay between feedback-based and predictive mechanisms. These processes rely heavily on target motion information available when the target is visible. However, short-term visual memory signals as well as implicit knowledge about the environment may also contribute to elaborate a predictive representation of the target trajectory, especially when visual feedback is partially unavailable because other objects occlude the visual target. To determine how different processes and information sources are integrated in the control of the interceptive action, we manipulated a computer-generated visual environment representing a baseball game. Twenty-four subjects intercepted fly-ball trajectories by moving a mouse cursor and by indicating the interception with a button press. In two separate sessions, fly-ball trajectories were either fully visible or occluded for 750, 1000 or 1250 ms before ball landing. Natural ball motion was perturbed during the descending trajectory with effects of either weightlessness (0 g or increased gravity (2 g at times such that, for occluded trajectories, 500 ms of perturbed motion were visible before ball disappearance. To examine the contribution of previous visual experience with the perturbed trajectories to the interception of invisible targets, the order of visible and occluded sessions was permuted among subjects. Under these experimental conditions, we showed that, with fully visible targets, subjects combined servo-control and predictive strategies. Instead, when intercepting occluded targets, subjects relied mostly on predictive mechanisms based, however, on different type of information depending on previous visual experience. In fact, subjects without prior experience of the perturbed trajectories showed interceptive errors consistent with predictive estimates of the ball trajectory based on a-priori knowledge of gravity. Conversely, the interceptive responses

  6. Soil organic carbon mapping of partially vegetated agricultural fields with imaging spectroscopy

    NARCIS (Netherlands)

    Bartholomeus, H.; Kooistra, L.; Stevens, A.; Leeuwen, van M.; Wesemael, van B.; Ben-Dor, E.; Tychon, B.

    2011-01-01

    Soil Organic Carbon (SOC) is one of the key soil properties, but the large spatial variation makes continuous mapping a complex task. Imaging spectroscopy has proven to be an useful technique for mapping of soil properties, but the applicability decreases rapidly when fields are partially covered

  7. Electronic eye occluder with time-counting and reflection control

    Science.gov (United States)

    Karitans, V.; Ozolinsh, M.; Kuprisha, G.

    2008-09-01

    In pediatric ophthalmology 2 - 3 % of all the children are impacted by a visual pathology - amblyopia. It develops if a clear image isn't presented to the retina during an early stage of the development of the visual system. A common way of treating this pathology is to cover the better-seeing eye to force the "lazy" eye to learn seeing. However, children are often reluctant to wear such an occluder because they are ashamed or simply because they find it inconvenient. This fact requires to find a way how to track the regime of occlusion because results of occlusion is a hint that the actual regime of occlusion isn't that what the optometrist has recommended. We design an electronic eye occluder that allows to track the regime of eye occlusion. We employ real-time clock DS1302 providing time information from seconds to years. Data is stored in the internal memory of the CPU (EEPROM). The MCU (PIC16F676) switches on only if a mechanical switch is closed and temperature has reached a satisfactory level. The occlusion is registered between time moments when the infrared signal appeared and disappeared.

  8. Gravel Image Segmentation in Noisy Background Based on Partial Entropy Method

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Because of wide variation in gray levels and particle dimensions and the presence of many small gravel objects in the background, as well as corrupting the image by noise, it is difficult o segment gravel objects. In this paper, we develop a partial entropy method and succeed to realize gravel objects segmentation. We give entropy principles and fur calculation methods. Moreover, we use minimum entropy error automaticly to select a threshold to segment image. We introduce the filter method using mathematical morphology. The segment experiments are performed by using different window dimensions for a group of gravel image and demonstrates that this method has high segmentation rate and low noise sensitivity.

  9. Parahippocampal epilepsy with subtle dysplasia: A cause of "imaging negative" partial epilepsy.

    Science.gov (United States)

    Pillay, Neelan; Fabinyi, Gavin C A; Myles, Terry S; Fitt, Gregory J; Berkovic, Samuel F; Jackson, Graeme D

    2009-12-01

    Lesion-negative refractory partial epilepsy is a major challenge in the assessment of patients for potential surgery. Finding a potential epileptogenic lesion simplifies assessment and is associated with good outcome. Here we describe imaging features of subtle parahippocampal dysplasia in five cases that were initially assessed as having imaging-negative frontal or temporal lobe epilepsy. We analyzed the clinical and imaging features of five patients with seizures from the parahippocampal region. Five patients had subtle but distinctive magnetic resonance imaging (MRI) abnormalities in the parahippocampal gyrus. This was a unilateral signal abnormality in the parahippocampal white matter extending into gray matter on heavily T(1)- and T(2)-weighted images with relative preservation of the gray-white matter boundary on T(1)-weighted volume sequences. Only one of these patients had typical electroclinical unilateral temporal lobe epilepsy (TLE); one mimicked frontal lobe epilepsy, two showed bitemporal seizures, and one had unlocalized partial seizures. All have had surgery; four are seizure-free (one has occasional auras only, follow-up 6 months to 10 years), and one has a >50% seizure reduction. Histopathologic evaluation suggested dysplastic features in the surgical specimens in all. In patients with lesion-negative partial epilepsy with frontal or temporal semiology, or in cases with apparent bitemporal seizures, subtle parahippocampal abnormalities should be carefully excluded. Recognizing the MRI findings of an abnormal parahippocampal gyrus can lead to successful surgery without invasive monitoring, despite apparently incongruent electroclinical features.

  10. Comparative diagnostic imaging of a partial patellar ligament tear in a dog

    Directory of Open Access Journals (Sweden)

    Mario Ricciardi

    2018-05-01

    Full Text Available Traumatic lesions of the patellar ligament (PL are rare in dogs. The resulting injury can be a complete or partial laceration, depending on the quantity of torn collagen fibres. Information obtained from imaging evaluation is of great value to the clinical approach towards PL injuries, because subsequent treatment options are affected by the distinction between complete or partial tears. Imaging diagnosis of PL damage in veterinary practice commonly relies on radiographic examination through the recognition of indirect signs, such as “patella alta”, bone fragments at the level of the patellar or tibial insertion, and soft tissue opacity at the cranial aspect of the joint. Although ultrasound (US and magnetic resonance imaging (MRI have been described as useful diagnostic tools for the assessment of PL tears in human patients, specific comparative data regarding the evaluation of PL rupture in dogs using different imaging modalities is lacking in the veterinary literature. This paper describes the radiographic, ultrasonographic, CT and MRI imaging findings of a partial PL tear in a dog and discusses the utility of these techniques in diagnosing this condition. CT provided more detailed information than X-ray examination in the assessment of the osteoligamentous junction, the exclusion of microfracture and distal PL avulsion, but did not add information regarding PL integrity. MRI and US provided the most useful information regarding intra-ligamentous damage and as such their combined use may be considered for the assessment of PL injuries after clinical examination and survey radiographs.

  11. Partial Fingerprint Image Enhancement using Region Division Technique and Morphological Transform

    International Nuclear Information System (INIS)

    Ahmad, A.; Arshad, I.; Raja, G.

    2015-01-01

    Fingerprints are the most renowned biometric trait for identification and verification. The quality of fingerprint image plays a vital role in feature extraction and matching. Existing algorithms work well for good quality fingerprint images and fail for partial fingerprint images as they are obtained from excessively dry fingers or affected by disease resulting in broken ridges. We propose an algorithm to enhance partial fingerprint images using morphological operatins with region division technique. The proposed method divides low quality image into six regions from top to bottom. Morphological operations choose an appropriate Structuring Element (SE) that joins broken ridges and thus enhance the image for further processing. The proposed method uses SE line with suitable angle theta and radius r in each region based on the orientation of the ridges. The algorithm is applied to 14 low quality fingerprint images from FVC-2002 database. Experimental results show that percentage accuracy has been improved using the proposed algorithm. The manual markup has been reduced and accuracy of 76.16% with Equal Error Rate (EER) of 3.16% is achieved. (author)

  12. Quantitative analysis of CT brain images: a statistical model incorporating partial volume and beam hardening effects

    International Nuclear Information System (INIS)

    McLoughlin, R.F.; Ryan, M.V.; Heuston, P.M.; McCoy, C.T.; Masterson, J.B.

    1992-01-01

    The purpose of this study was to construct and evaluate a statistical model for the quantitative analysis of computed tomographic brain images. Data were derived from standard sections in 34 normal studies. A model representing the intercranial pure tissue and partial volume areas, with allowance for beam hardening, was developed. The average percentage error in estimation of areas, derived from phantom tests using the model, was 28.47%. We conclude that our model is not sufficiently accurate to be of clinical use, even though allowance was made for partial volume and beam hardening effects. (author)

  13. Kalisphera: an analytical tool to reproduce the partial volume effect of spheres imaged in 3D

    International Nuclear Information System (INIS)

    Tengattini, Alessandro; Andò, Edward

    2015-01-01

    In experimental mechanics, where 3D imaging is having a profound effect, spheres are commonly adopted for their simplicity and for the ease of their modeling. In this contribution we develop an analytical tool, ‘kalisphera’, to produce 3D raster images of spheres including their partial volume effect. This allows us to evaluate the metrological performance of existing image-based measurement techniques (knowing a priori the ground truth). An advanced application of ‘kalisphera’ is developed here to identify and accurately characterize spheres in real 3D x-ray tomography images with the objective of improving trinarization and contact detection. The effect of the common experimental imperfections is assessed and the overall performance of the tool tested on real images. (paper)

  14. Combustion stratification study of partially premixed combustion using Fourier transform analysis of OH* chemiluminescence images

    KAUST Repository

    Izadi Najafabadi, Mohammad

    2017-11-06

    A relatively high level of stratification (qualitatively: lack of homogeneity) is one of the main advantages of partially premixed combustion over the homogeneous charge compression ignition concept. Stratification can smooth the heat release rate and improve the controllability of combustion. In order to compare stratification levels of different partially premixed combustion strategies or other combustion concepts, an objective and meaningful definition of “stratification level” is required. Such a definition is currently lacking; qualitative/quantitative definitions in the literature cannot properly distinguish various levels of stratification. The main purpose of this study is to objectively define combustion stratification (not to be confused with fuel stratification) based on high-speed OH* chemiluminescence imaging, which is assumed to provide spatial information regarding heat release. Stratification essentially being equivalent to spatial structure, we base our definition on two-dimensional Fourier transforms of photographs of OH* chemiluminescence. A light-duty optical diesel engine has been used to perform the OH* bandpass imaging on. Four experimental points are evaluated, with injection timings in the homogeneous regime as well as in the stratified partially premixed combustion regime. Two-dimensional Fourier transforms translate these chemiluminescence images into a range of spatial frequencies. The frequency information is used to define combustion stratification, using a novel normalization procedure. The results indicate that this new definition, based on Fourier analysis of OH* bandpass images, overcomes the drawbacks of previous definitions used in the literature and is a promising method to compare the level of combustion stratification between different experiments.

  15. Ghost imaging and its visibility with partially coherent elliptical Gaussian Schell-model beams

    International Nuclear Information System (INIS)

    Luo, Meilan; Zhu, Weiting; Zhao, Daomu

    2015-01-01

    The performances of the ghost image and the visibility with partially coherent elliptical Gaussian Schell-model beams have been studied. In that case we have derived the condition under which the goal ghost image is achievable. Furthermore, the visibility is assessed in terms of the parameters related to the source to find that the visibility reduces with the increase of the beam size, while it is a monotonic increasing function of the transverse coherence length. More specifically, it is found that the inequalities of the source sizes in x and y directions, as well as the transverse coherence lengths, play an important role in the ghost image and the visibility. - Highlights: • We studied the ghost image and visibility with partially coherent EGSM beams. • We derived the condition under which the goal ghost image is achievable. • The visibility is assessed in terms of the parameters related to the source. • The source sizes and coherence lengths play role in the ghost image and visibility.

  16. Transcatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus.

    Science.gov (United States)

    Wierzyk, Arkadiusz; Szkutnik, Małgorzata; Fiszer, Roland; Banaszak, Paweł; Pawlak, Szymon; Białkowski, Jacek

    2014-01-01

    Ventricular septal defects closure (VSD) depending on the anatomy and clinical setting can be performed surgically or by a hybrid and transcatheter approach. Two cases of children with VSD will be presented. Patients' defects were closed with various types of occluders made of nitinol wire mesh occluder, patent ductus arteriosus (PDA) type. The first case was a 2.5-year-old boy after cardiosurgical correction of tetralogy of Fallot (TOF). After the procedure, a significant haemodynamic residual VSD was observed, which was not successfully closed during the subsequent reoperation. Despite pharmacological treatment, symptoms of heart failure were observed in this patient. In echocardiographic images the residual VSD was presented as a tunnel-like dissection of the ventricular septum (length 6 mm and diameter 3.4 mm). The defect was closed via arterial access with an Amplatzer Duct Occluder II (ADO II). The procedure was successfully performed without any medical complications. In this child, a significant shunt reduction and a noticeable improvement in the patient's clinical status and diminished symptoms of heart failure were noticed. The second patient was a 4-year-old girl suffering from a multi-perforated perimembranous VSD accompanied by a ventricular septal defect with aneurysm. The defect was closed by a venous approach with a PDA Cardio-O-Fix occluder (very similar to ADO I). No short-term or long-term complications were visible during or after the procedure. Only a mild residual shunt through the VSD was observed 6 months afterwards. Transcatheter VSD closure with a proper morphology, with occluders of type Amplatzer Duct Occluder ADO I or ADO II, constitutes a safe and effective therapeutic alternative.

  17. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration.

    Science.gov (United States)

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-04-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment.

  18. ADI splitting schemes for a fourth-order nonlinear partial differential equation from image processing

    KAUST Repository

    Calatroni, Luca

    2013-08-01

    We present directional operator splitting schemes for the numerical solution of a fourth-order, nonlinear partial differential evolution equation which arises in image processing. This equation constitutes the H -1-gradient flow of the total variation and represents a prototype of higher-order equations of similar type which are popular in imaging for denoising, deblurring and inpainting problems. The efficient numerical solution of this equation is very challenging due to the stiffness of most numerical schemes. We show that the combination of directional splitting schemes with implicit time-stepping provides a stable and computationally cheap numerical realisation of the equation.

  19. Combining MRI with PET for partial volume correction improves image-derived input functions in mice

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Eleanor; Buonincontri, Guido [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Izquierdo, David [Athinoula A Martinos Centre, Harvard University, Cambridge, MA (United States); Methner, Carmen [Department of Medicine, University of Cambridge, Cambridge (United Kingdom); Hawkes, Rob C [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Ansorge, Richard E [Department of Physics, University of Cambridge, Cambridge (United Kingdom); Kreig, Thomas [Department of Medicine, University of Cambridge, Cambridge (United Kingdom); Carpenter, T Adrian [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Sawiak, Stephen J [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Behavioural and Clinical Neurosciences Institute, University of Cambridge, Cambridge (United Kingdom)

    2014-07-29

    Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. This measure is challenging to obtain in mice due to low blood volumes, resulting in a reliance on image-based methods for AIF derivation. We present a comparison of PET- and MR-based region-of-interest (ROI) analysis to obtain image-derived AIFs from the left ventricle (LV) of a mouse model. ROI-based partial volume correction (PVC) was performed to improve quantification.

  20. Combining MRI with PET for partial volume correction improves image-derived input functions in mice

    International Nuclear Information System (INIS)

    Evans, Eleanor; Buonincontri, Guido; Izquierdo, David; Methner, Carmen; Hawkes, Rob C; Ansorge, Richard E; Kreig, Thomas; Carpenter, T Adrian; Sawiak, Stephen J

    2014-01-01

    Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. This measure is challenging to obtain in mice due to low blood volumes, resulting in a reliance on image-based methods for AIF derivation. We present a comparison of PET- and MR-based region-of-interest (ROI) analysis to obtain image-derived AIFs from the left ventricle (LV) of a mouse model. ROI-based partial volume correction (PVC) was performed to improve quantification.

  1. ADI splitting schemes for a fourth-order nonlinear partial differential equation from image processing

    KAUST Repository

    Calatroni, Luca; Dü ring, Bertram; Schö nlieb, Carola-Bibiane

    2013-01-01

    We present directional operator splitting schemes for the numerical solution of a fourth-order, nonlinear partial differential evolution equation which arises in image processing. This equation constitutes the H -1-gradient flow of the total variation and represents a prototype of higher-order equations of similar type which are popular in imaging for denoising, deblurring and inpainting problems. The efficient numerical solution of this equation is very challenging due to the stiffness of most numerical schemes. We show that the combination of directional splitting schemes with implicit time-stepping provides a stable and computationally cheap numerical realisation of the equation.

  2. Numerical Simulation of Partially-Coherent Broadband Optical Imaging Using the FDTD Method

    Science.gov (United States)

    Çapoğlu, İlker R.; White, Craig A.; Rogers, Jeremy D.; Subramanian, Hariharan; Taflove, Allen; Backman, Vadim

    2012-01-01

    Rigorous numerical modeling of optical systems has attracted interest in diverse research areas ranging from biophotonics to photolithography. We report the full-vector electromagnetic numerical simulation of a broadband optical imaging system with partially-coherent and unpolarized illumination. The scattering of light from the sample is calculated using the finite-difference time-domain (FDTD) numerical method. Geometrical optics principles are applied to the scattered light to obtain the intensity distribution at the image plane. Multilayered object spaces are also supported by our algorithm. For the first time, numerical FDTD calculations are directly compared to and shown to agree well with broadband experimental microscopy results. PMID:21540939

  3. Radar Determination of Fault Slip and Location in Partially Decorrelated Images

    Science.gov (United States)

    Parker, Jay; Glasscoe, Margaret; Donnellan, Andrea; Stough, Timothy; Pierce, Marlon; Wang, Jun

    2017-06-01

    Faced with the challenge of thousands of frames of radar interferometric images, automated feature extraction promises to spur data understanding and highlight geophysically active land regions for further study. We have developed techniques for automatically determining surface fault slip and location using deformation images from the NASA Uninhabited Aerial Vehicle Synthetic Aperture Radar (UAVSAR), which is similar to satellite-based SAR but has more mission flexibility and higher resolution (pixels are approximately 7 m). This radar interferometry provides a highly sensitive method, clearly indicating faults slipping at levels of 10 mm or less. But interferometric images are subject to decorrelation between revisit times, creating spots of bad data in the image. Our method begins with freely available data products from the UAVSAR mission, chiefly unwrapped interferograms, coherence images, and flight metadata. The computer vision techniques we use assume no data gaps or holes; so a preliminary step detects and removes spots of bad data and fills these holes by interpolation and blurring. Detected and partially validated surface fractures from earthquake main shocks, aftershocks, and aseismic-induced slip are shown for faults in California, including El Mayor-Cucapah (M7.2, 2010), the Ocotillo aftershock (M5.7, 2010), and South Napa (M6.0, 2014). Aseismic slip is detected on the San Andreas Fault from the El Mayor-Cucapah earthquake, in regions of highly patterned partial decorrelation. Validation is performed by comparing slip estimates from two interferograms with published ground truth measurements.

  4. A generalized framework unifying image registration and respiratory motion models and incorporating image reconstruction, for partial image data or full images

    Science.gov (United States)

    McClelland, Jamie R.; Modat, Marc; Arridge, Simon; Grimes, Helen; D'Souza, Derek; Thomas, David; O' Connell, Dylan; Low, Daniel A.; Kaza, Evangelia; Collins, David J.; Leach, Martin O.; Hawkes, David J.

    2017-06-01

    Surrogate-driven respiratory motion models relate the motion of the internal anatomy to easily acquired respiratory surrogate signals, such as the motion of the skin surface. They are usually built by first using image registration to determine the motion from a number of dynamic images, and then fitting a correspondence model relating the motion to the surrogate signals. In this paper we present a generalized framework that unifies the image registration and correspondence model fitting into a single optimization. This allows the use of ‘partial’ imaging data, such as individual slices, projections, or k-space data, where it would not be possible to determine the motion from an individual frame of data. Motion compensated image reconstruction can also be incorporated using an iterative approach, so that both the motion and a motion-free image can be estimated from the partial image data. The framework has been applied to real 4DCT, Cine CT, multi-slice CT, and multi-slice MR data, as well as simulated datasets from a computer phantom. This includes the use of a super-resolution reconstruction method for the multi-slice MR data. Good results were obtained for all datasets, including quantitative results for the 4DCT and phantom datasets where the ground truth motion was known or could be estimated.

  5. A multimodal imaging framework for enhanced robot-assisted partial nephrectomy guidance

    Science.gov (United States)

    Halter, Ryan J.; Wu, Xiaotian; Hartov, Alex; Seigne, John; Khan, Shadab

    2015-03-01

    Robot-assisted laparoscopic partial nephrectomies (RALPN) are performed to treat patients with locally confined renal carcinoma. There are well-documented benefits to performing partial (opposed to radical) kidney resections and to using robot-assisted laparoscopic (opposed to open) approaches. However, there are challenges in identifying tumor margins and critical benign structures including blood vessels and collecting systems during current RALPN procedures. The primary objective of this effort is to couple multiple image and data streams together to augment visual information currently provided to surgeons performing RALPN and ultimately ensure complete tumor resection and minimal damage to functional structures (i.e. renal vasculature and collecting systems). To meet this challenge we have developed a framework and performed initial feasibility experiments to couple pre-operative high-resolution anatomic images with intraoperative MRI, ultrasound (US) and optical-based surface mapping and kidney tracking. With these registered images and data streams, we aim to overlay the high-resolution contrast-enhanced anatomic (CT or MR) images onto the surgeon's view screen for enhanced guidance. To date we have integrated the following components of our framework: 1) a method for tracking an intraoperative US probe to extract the kidney surface and a set of embedded kidney markers, 2) a method for co-registering intraoperative US scans with pre-operative MR scans, and 3) a method for deforming pre-op scans to match intraoperative scans. These components have been evaluated through phantom studies to demonstrate protocol feasibility.

  6. Three tesla magnetic resonance imaging of the anterior cruciate ligament of the knee: can we differentiate complete from partial tears?

    Energy Technology Data Exchange (ETDEWEB)

    Dyck, Pieter van; Gielen, Jan L.; Parizel, Paul M. [University Hospital Antwerp and University of Antwerp, Department of Radiology, Antwerp (Edegem) (Belgium); Vanhoenacker, Filip M. [University Hospital Antwerp and University of Antwerp, Department of Radiology, Antwerp (Edegem) (Belgium); AZ St-Maarten Duffel/Mechelen, Department of Radiology, Duffel (Belgium); Dossche, Lieven; Gestel, Jozef van [University Hospital Antwerp and University of Antwerp, Department of Orthopedics, Antwerp (Edegem) (Belgium); Wouters, Kristien [University Hospital Antwerp and University of Antwerp, Department of Scientific Coordination and Biostatistics, Antwerp (Edegem) (Belgium)

    2011-06-15

    To determine the ability of 3.0T magnetic resonance (MR) imaging to identify partial tears of the anterior cruciate ligament (ACL) and to allow distinction of complete from partial ACL tears. One hundred seventy-two patients were prospectively studied by 3.0T MR imaging and arthroscopy in our institution. MR images were interpreted in consensus by two experienced reviewers, and the ACL was diagnosed as being normal, partially torn, or completely torn. Diagnostic accuracy of 3.0T MR for the detection of both complete and partial tears of the ACL was calculated using arthroscopy as the standard of reference. There were 132 patients with an intact ACL, 17 had a partial, and 23 had a complete tear of the ACL seen at arthroscopy. Sensitivity, specificity, and accuracy of 3.0T MR for complete ACL tears were 83, 99, and 97%, respectively, and, for partial ACL tears, 77, 97, and 95%, respectively. Five of 40 ACL lesions (13%) could not correctly be identified as complete or partial ACL tears. MR imaging at 3.0T represents a highly accurate method for identifying tears of the ACL. However, differentiation between complete and partial ACL tears and identification of partial tears of this ligament remains difficult, even at 3.0T. (orig.)

  7. Three tesla magnetic resonance imaging of the anterior cruciate ligament of the knee: can we differentiate complete from partial tears?

    International Nuclear Information System (INIS)

    Dyck, Pieter van; Gielen, Jan L.; Parizel, Paul M.; Vanhoenacker, Filip M.; Dossche, Lieven; Gestel, Jozef van; Wouters, Kristien

    2011-01-01

    To determine the ability of 3.0T magnetic resonance (MR) imaging to identify partial tears of the anterior cruciate ligament (ACL) and to allow distinction of complete from partial ACL tears. One hundred seventy-two patients were prospectively studied by 3.0T MR imaging and arthroscopy in our institution. MR images were interpreted in consensus by two experienced reviewers, and the ACL was diagnosed as being normal, partially torn, or completely torn. Diagnostic accuracy of 3.0T MR for the detection of both complete and partial tears of the ACL was calculated using arthroscopy as the standard of reference. There were 132 patients with an intact ACL, 17 had a partial, and 23 had a complete tear of the ACL seen at arthroscopy. Sensitivity, specificity, and accuracy of 3.0T MR for complete ACL tears were 83, 99, and 97%, respectively, and, for partial ACL tears, 77, 97, and 95%, respectively. Five of 40 ACL lesions (13%) could not correctly be identified as complete or partial ACL tears. MR imaging at 3.0T represents a highly accurate method for identifying tears of the ACL. However, differentiation between complete and partial ACL tears and identification of partial tears of this ligament remains difficult, even at 3.0T. (orig.)

  8. Diagnosis of partial and complete rotator cuff tears using combined gradient echo and spin echo imaging

    International Nuclear Information System (INIS)

    Tuite, M.J.; Yandow, D.R.; DeSmet, A.A.; Orwin, J.F.; Quintana, F.A.

    1994-01-01

    Most magnetic resonance (MR) studies evaluating the rotator cuff for tears have used T2-weighted imaging in the coronal oblique and sagittal oblique planes. T2 * -weighted gradient echo imaging, however, has advantages over spin echo imaging, including contiguous slices without cross-talk, high contrast around the cuff, and intrinsically shorter imaging times which can be used to increase the number of signals averaged and thus improve the signal-to-noise ratio. We reviewed the shoulder MR scans of 87 consecutive patients who underwent both a MR scan and a shoulder arthroscopy during which the size of tears, if present, was graded. The reviewers were blinded as to the history and arthroscopic results. The MR scans included oblique coronal T2 * -weighted gradient echo and oblique sagittal T2-weighted spin echo images. MR cuff grades were correlated with arthroscopic findings. For complete tears, the sensitivity of MR was 0.91 and the specificity 0.95. For partial tears, the sensitivity was 0.74 and the specificity 0.87. This accuracy is similar to two-plane T2-weighted imaging as previously reported in the literature. There was a statistically significant correlation (p < 0.0005) between the cuff grade as determined by MR and the arthroscopic findings. (orig.)

  9. Diagnosis of partial and complete rotator cuff tears using combined gradient echo and spin echo imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J [Dept. of Radiology, Univ. of Wisconsin, Madison, WI (United States); Yandow, D R [Dept. of Radiology, Univ. of Wisconsin, Madison, WI (United States); DeSmet, A A [Dept. of Radiology, Univ. of Wisconsin, Madison, WI (United States); Orwin, J F [Div. of Orthopedic Surgery, Univ. of Wisconsin, Madison, WI (United States); Quintana, F A [Dept. of Biostatistics, Univ. of Wisconsin, Madison, WI (United States)

    1994-10-01

    Most magnetic resonance (MR) studies evaluating the rotator cuff for tears have used T2-weighted imaging in the coronal oblique and sagittal oblique planes. T2{sup *}-weighted gradient echo imaging, however, has advantages over spin echo imaging, including contiguous slices without cross-talk, high contrast around the cuff, and intrinsically shorter imaging times which can be used to increase the number of signals averaged and thus improve the signal-to-noise ratio. We reviewed the shoulder MR scans of 87 consecutive patients who underwent both a MR scan and a shoulder arthroscopy during which the size of tears, if present, was graded. The reviewers were blinded as to the history and arthroscopic results. The MR scans included oblique coronal T2{sup *}-weighted gradient echo and oblique sagittal T2-weighted spin echo images. MR cuff grades were correlated with arthroscopic findings. For complete tears, the sensitivity of MR was 0.91 and the specificity 0.95. For partial tears, the sensitivity was 0.74 and the specificity 0.87. This accuracy is similar to two-plane T2-weighted imaging as previously reported in the literature. There was a statistically significant correlation (p < 0.0005) between the cuff grade as determined by MR and the arthroscopic findings. (orig.)

  10. Using the phase-space imager to analyze partially coherent imaging systems: bright-field, phase contrast, differential interference contrast, differential phase contrast, and spiral phase contrast

    Science.gov (United States)

    Mehta, Shalin B.; Sheppard, Colin J. R.

    2010-05-01

    Various methods that use large illumination aperture (i.e. partially coherent illumination) have been developed for making transparent (i.e. phase) specimens visible. These methods were developed to provide qualitative contrast rather than quantitative measurement-coherent illumination has been relied upon for quantitative phase analysis. Partially coherent illumination has some important advantages over coherent illumination and can be used for measurement of the specimen's phase distribution. However, quantitative analysis and image computation in partially coherent systems have not been explored fully due to the lack of a general, physically insightful and computationally efficient model of image formation. We have developed a phase-space model that satisfies these requirements. In this paper, we employ this model (called the phase-space imager) to elucidate five different partially coherent systems mentioned in the title. We compute images of an optical fiber under these systems and verify some of them with experimental images. These results and simulated images of a general phase profile are used to compare the contrast and the resolution of the imaging systems. We show that, for quantitative phase imaging of a thin specimen with matched illumination, differential phase contrast offers linear transfer of specimen information to the image. We also show that the edge enhancement properties of spiral phase contrast are compromised significantly as the coherence of illumination is reduced. The results demonstrate that the phase-space imager model provides a useful framework for analysis, calibration, and design of partially coherent imaging methods.

  11. Comparison of sonography and magnetic resonance imaging for the diagnosis of partial tears of finger extensor tendons in rheumatoid arthritis

    NARCIS (Netherlands)

    Swen, W. A.; Jacobs, J. W.; Hubach, P. C.; Klasens, J. H.; Algra, P. R.; Bijlsma, J. W.

    2000-01-01

    Finger extensor tenosynovitis in rheumatoid arthritis (RA) may lead to partial and eventually to complete tendon tears. The aim of this study was to investigate the diagnostic value of sonography (SG) and/or magnetic resonance imaging (MRI) to visualize partial tendon tears. Twenty-one RA patients

  12. A multiresolution image based approach for correction of partial volume effects in emission tomography

    International Nuclear Information System (INIS)

    Boussion, N; Hatt, M; Lamare, F; Bizais, Y; Turzo, A; Rest, C Cheze-Le; Visvikis, D

    2006-01-01

    Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography. They lead to a loss of signal in tissues of size similar to the point spread function and induce activity spillover between regions. Although PVE can be corrected for by using algorithms that provide the correct radioactivity concentration in a series of regions of interest (ROIs), so far little attention has been given to the possibility of creating improved images as a result of PVE correction. Potential advantages of PVE-corrected images include the ability to accurately delineate functional volumes as well as improving tumour-to-background ratio, resulting in an associated improvement in the analysis of response to therapy studies and diagnostic examinations, respectively. The objective of our study was therefore to develop a methodology for PVE correction not only to enable the accurate recuperation of activity concentrations, but also to generate PVE-corrected images. In the multiresolution analysis that we define here, details of a high-resolution image H (MRI or CT) are extracted, transformed and integrated in a low-resolution image L (PET or SPECT). A discrete wavelet transform of both H and L images is performed by using the 'a trous' algorithm, which allows the spatial frequencies (details, edges, textures) to be obtained easily at a level of resolution common to H and L. A model is then inferred to build the lacking details of L from the high-frequency details in H. The process was successfully tested on synthetic and simulated data, proving the ability to obtain accurately corrected images. Quantitative PVE correction was found to be comparable with a method considered as a reference but limited to ROI analyses. Visual improvement and quantitative correction were also obtained in two examples of clinical images, the first using a combined PET/CT scanner with a lymphoma patient and the second using a FDG brain PET and corresponding T1-weighted MRI in

  13. Clinical utility of partial flip angle T2-weighted spin-echo imaging of the brain

    International Nuclear Information System (INIS)

    Chang, K.H.; Yi, J.G.; Han, M.H.; Han, M.C.; Kim, C.W.; Cho, M.H.; Cho, Z.H.

    1990-01-01

    To assess the clinical usefulness of partial flip angle (PFA) spin-echo (SE) brain imaging, a total of eighty patients were examined with both conventional double echo T2-weighted SE (2500/30, 80/90deg/one excitation) and PFA double echo SE (1200/30, 70/45deg/two excitations) on 2.0T system. Two comparative studies were performed: (1) In 65 patients PFA SE technique was compared with conventional SE without flow compensating gradients, and (2) in 15 patients the former was compared with the latter with flow compensating gradients. Imaging time was nearly identical in each sequence. In both studies we found that PFA T2-weighted SE images were almost identical to those obtained with the conventional SE technique in the contrast characteristics and the detection rate of the abnormalities (100%, 85/85 lesions), and more importantly, PFA SE revealed few flow artifacts in the brain stem, temporal lobes and basal ganglia which were frequently seen on conventional SE without flow compensating gradients. Additionally, PFA SE images demonstrated no suppression of CSF flow void in the aqueduct which was commonly seen on conventional SE with flow compensating gradients. In overall image quality, the PFA SE images, particularly the second echo images, were almost comparable with those of conventional SE with flow compensating gradients. A flip angle of 45deg seems to be close to Ernst angle, the angle at which maximum signal occurs, for a given TR of 1200 msec for CSF and most of the abnormalities containing higher water content. In conclusion, PFA SE sequence (i.e. 1200/30, 70/45deg/2) appears to be useful as a primary or an adjunctive technique in certain clinical circumstances, particularly in imaging of hydrocephalic patients for assessing aqueductal patency. (orig.)

  14. Imaging the equilibrium state and magnetization dynamics of partially built hard disk write heads

    Energy Technology Data Exchange (ETDEWEB)

    Valkass, R. A. J., E-mail: rajv202@ex.ac.uk; Yu, W.; Shelford, L. R.; Keatley, P. S.; Loughran, T. H. J.; Hicken, R. J. [School of Physics, University of Exeter, Stocker Road, Exeter EX4 4QL (United Kingdom); Cavill, S. A. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE (United Kingdom); Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Laan, G. van der; Dhesi, S. S. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE (United Kingdom); Bashir, M. A.; Gubbins, M. A. [Research and Development, Seagate Technology, 1 Disc Drive, Springtown Industrial Estate, Derry BT48 0BF (United Kingdom); Czoschke, P. J.; Lopusnik, R. [Recording Heads Operation, Seagate Technology, 7801 Computer Avenue South, Bloomington, Minnesota 55435 (United States)

    2015-06-08

    Four different designs of partially built hard disk write heads with a yoke comprising four repeats of NiFe (1 nm)/CoFe (50 nm) were studied by both x-ray photoemission electron microscopy (XPEEM) and time-resolved scanning Kerr microscopy (TRSKM). These techniques were used to investigate the static equilibrium domain configuration and the magnetodynamic response across the entire structure, respectively. Simulations and previous TRSKM studies have made proposals for the equilibrium domain configuration of similar structures, but no direct observation of the equilibrium state of the writers has yet been made. In this study, static XPEEM images of the equilibrium state of writer structures were acquired using x-ray magnetic circular dichroism as the contrast mechanism. These images suggest that the crystalline anisotropy dominates the equilibrium state domain configuration, but competition with shape anisotropy ultimately determines the stability of the equilibrium state. Dynamic TRSKM images were acquired from nominally identical devices. These images suggest that a longer confluence region may hinder flux conduction from the yoke into the pole tip: the shorter confluence region exhibits clear flux beaming along the symmetry axis, whereas the longer confluence region causes flux to conduct along one edge of the writer. The observed variations in dynamic response agree well with the differences in the equilibrium magnetization configuration visible in the XPEEM images, confirming that minor variations in the geometric design of the writer structure can have significant effects on the process of flux beaming.

  15. Partial epilepsy: A pictorial review of 3 TESLA magnetic resonance imaging features

    Directory of Open Access Journals (Sweden)

    Lucas Giansante Abud

    2015-09-01

    Full Text Available Epilepsy is a disease with serious consequences for patients and society. In many cases seizures are sufficiently disabling to justify surgical evaluation. In this context, Magnetic Resonance Imaging (MRI is one of the most valuable tools for the preoperative localization of epileptogenic foci. Because these lesions show a large variety of presentations (including subtle imaging characteristics, their analysis requires careful and systematic interpretation of MRI data. Several studies have shown that 3 Tesla (T MRI provides a better image quality than 1.5 T MRI regarding the detection and characterization of structural lesions, indicating that high-field-strength imaging should be considered for patients with intractable epilepsy who might benefit from surgery. Likewise, advanced MRI postprocessing and quantitative analysis techniques such as thickness and volume measurements of cortical gray matter have emerged and in the near future, these techniques will routinely enable more precise evaluations of such patients. Finally, the familiarity with radiologic findings of the potential epileptogenic substrates in association with combined use of higher field strengths (3 T, 7 T, and greater and new quantitative analytical post-processing techniques will lead to improvements regarding the clinical imaging of these patients. We present a pictorial review of the major pathologies related to partial epilepsy, highlighting the key findings of 3 T MRI.

  16. Single-shot magnetic resonance spectroscopic imaging with partial parallel imaging.

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2009-03-01

    A magnetic resonance spectroscopic imaging (MRSI) pulse sequence based on proton-echo-planar-spectroscopic-imaging (PEPSI) is introduced that measures two-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3-T whole-body scanner equipped with a 12-channel array coil. Four-step interleaved phase encoding and fourfold SENSE acceleration were used to encode a 16 x 16 spatial matrix with a 390-Hz spectral width. Comparison with conventional PEPSI and PEPSI with fourfold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor-related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of inositol, choline, creatine, and N-acetyl-aspartate (NAA) in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement.

  17. Image-quality degradation in a turbid medium under partially coherent illumination

    International Nuclear Information System (INIS)

    Zardecki, A.; Gerstl, S.A.W.; Tam, W.G.; Embury, J.F.

    1986-01-01

    The image-quality degradation as a result of propagation through a turbid medium is analyzed within the small-angle approximation to the equation of transfer. By using the well-known correspondence between the radiance distribution and the mutual-coherence function, we formulate a factorization assumption for the mutual coherence in order to restrict the class of radiance distributions in the object plane. Depending on the contrast factor, that is, in general, the class of partially coherent light beams. The general formula for the irradiance distribution in the image plane contains the classic result of Hufnagel and Stanley [J. Opt. Soc. Am. 54, 52 (1964)] as a special case. We study the limits of an infinite lens and a Gaussian aperture and investigate in detail the case of a Gaussian beam with a cosinusoidally superimposed signal. The solution in the form of a multiple-scattering series enables us to discuss the signficance of scattering events of higher order

  18. MRI-negative refractory partial epilepsy: role for diffusion tensor imaging in high field MRI.

    Science.gov (United States)

    Chen, Qin; Lui, Su; Li, Chun-Xiao; Jiang, Li-Jun; Ou-Yang, Luo; Tang, He-Han; Shang, Hui-Fang; Huang, Xiao-Qi; Gong, Qi-Yong; Zhou, Dong

    2008-07-01

    Our aim is to use the high field MR scanner (3T) to verify whether diffusion tensor imaging (DTI) could help in locating the epileptogenic zone in patients with MRI-negative refractory partial epilepsy. Fifteen patients with refractory partial epilepsy who had normal conventional MRI, and 40 healthy volunteers were recruited for the study. DTI was performed on a 3T MR scanner, individual maps of mean diffusivity (MD) and fractional anisotropy (FA) were calculated, and Voxel-Based Analysis (VBA) was performed for individual comparison between patients and controls. Voxel-based analysis revealed significant MD increase in variant regions in 13 patients. The electroclinical seizure localization was concurred to seven patients. No patient exhibited regions of significant decreased MD. Regions of significant reduced FA were observed in five patients, with two of these concurring with electroclinical seizure localization. Two patients had regions of significant increase in FA, which were distinct from electroclinical seizure localization. Our study's results revealed that DTI is a responsive neuroradiologic technique that provides information about the epileptogenic areas in patients with MRI-negative refractory partial epilepsy. This technique may also helpful in pre-surgical evaluation.

  19. Cardiac motion correction based on partial angle reconstructed images in x-ray CT

    International Nuclear Information System (INIS)

    Kim, Seungeon; Chang, Yongjin; Ra, Jong Beom

    2015-01-01

    Purpose: Cardiac x-ray CT imaging is still challenging due to heart motion, which cannot be ignored even with the current rotation speed of the equipment. In response, many algorithms have been developed to compensate remaining motion artifacts by estimating the motion using projection data or reconstructed images. In these algorithms, accurate motion estimation is critical to the compensated image quality. In addition, since the scan range is directly related to the radiation dose, it is preferable to minimize the scan range in motion estimation. In this paper, the authors propose a novel motion estimation and compensation algorithm using a sinogram with a rotation angle of less than 360°. The algorithm estimates the motion of the whole heart area using two opposite 3D partial angle reconstructed (PAR) images and compensates the motion in the reconstruction process. Methods: A CT system scans the thoracic area including the heart over an angular range of 180° + α + β, where α and β denote the detector fan angle and an additional partial angle, respectively. The obtained cone-beam projection data are converted into cone-parallel geometry via row-wise fan-to-parallel rebinning. Two conjugate 3D PAR images, whose center projection angles are separated by 180°, are then reconstructed with an angular range of β, which is considerably smaller than a short scan range of 180° + α. Although these images include limited view angle artifacts that disturb accurate motion estimation, they have considerably better temporal resolution than a short scan image. Hence, after preprocessing these artifacts, the authors estimate a motion model during a half rotation for a whole field of view via nonrigid registration between the images. Finally, motion-compensated image reconstruction is performed at a target phase by incorporating the estimated motion model. The target phase is selected as that corresponding to a view angle that is orthogonal to the center view angles of

  20. Cardiac motion correction based on partial angle reconstructed images in x-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seungeon; Chang, Yongjin; Ra, Jong Beom, E-mail: jbra@kaist.ac.kr [Department of Electrical Engineering, KAIST, Daejeon 305-701 (Korea, Republic of)

    2015-05-15

    Purpose: Cardiac x-ray CT imaging is still challenging due to heart motion, which cannot be ignored even with the current rotation speed of the equipment. In response, many algorithms have been developed to compensate remaining motion artifacts by estimating the motion using projection data or reconstructed images. In these algorithms, accurate motion estimation is critical to the compensated image quality. In addition, since the scan range is directly related to the radiation dose, it is preferable to minimize the scan range in motion estimation. In this paper, the authors propose a novel motion estimation and compensation algorithm using a sinogram with a rotation angle of less than 360°. The algorithm estimates the motion of the whole heart area using two opposite 3D partial angle reconstructed (PAR) images and compensates the motion in the reconstruction process. Methods: A CT system scans the thoracic area including the heart over an angular range of 180° + α + β, where α and β denote the detector fan angle and an additional partial angle, respectively. The obtained cone-beam projection data are converted into cone-parallel geometry via row-wise fan-to-parallel rebinning. Two conjugate 3D PAR images, whose center projection angles are separated by 180°, are then reconstructed with an angular range of β, which is considerably smaller than a short scan range of 180° + α. Although these images include limited view angle artifacts that disturb accurate motion estimation, they have considerably better temporal resolution than a short scan image. Hence, after preprocessing these artifacts, the authors estimate a motion model during a half rotation for a whole field of view via nonrigid registration between the images. Finally, motion-compensated image reconstruction is performed at a target phase by incorporating the estimated motion model. The target phase is selected as that corresponding to a view angle that is orthogonal to the center view angles of

  1. Patch Similarity Modulus and Difference Curvature Based Fourth-Order Partial Differential Equation for Image Denoising

    Directory of Open Access Journals (Sweden)

    Yunjiao Bai

    2015-01-01

    Full Text Available The traditional fourth-order nonlinear diffusion denoising model suffers the isolated speckles and the loss of fine details in the processed image. For this reason, a new fourth-order partial differential equation based on the patch similarity modulus and the difference curvature is proposed for image denoising. First, based on the intensity similarity of neighbor pixels, this paper presents a new edge indicator called patch similarity modulus, which is strongly robust to noise. Furthermore, the difference curvature which can effectively distinguish between edges and noise is incorporated into the denoising algorithm to determine the diffusion process by adaptively adjusting the size of the diffusion coefficient. The experimental results show that the proposed algorithm can not only preserve edges and texture details, but also avoid isolated speckles and staircase effect while filtering out noise. And the proposed algorithm has a better performance for the images with abundant details. Additionally, the subjective visual quality and objective evaluation index of the denoised image obtained by the proposed algorithm are higher than the ones from the related methods.

  2. Comparative analysis of partial imaging performance parameters of home and imported X-ray machines

    International Nuclear Information System (INIS)

    Cao Yunxi; Wang Xianyun; Liu Huiqin; Guo Yongxin

    2002-01-01

    Objective: To compare and analyze the performance indexes and the imaging quality of the home and imported X-ray machines through testing their partial imaging performance parameters. Methods: By separate sampling from 10 home and 10 imported X-ray machines, the parameters including tube current, time of exposure, machine total exposure, and repeatability were tested, and the imaging performance was evaluated according to the national standard. Results: All the performance indexes met the standard of GB4505-84. The first sampling tests showed the maximum changing coefficient of imaging performance repeatability of the home X-ray machines was Δmax1 = 0.025, while that of the imported X-ray machine was Δmax1 = 0.016. In the second sampling tests, the maximum changing coefficients of the two were Δmax2 = 0.048 and Δmax2 = 0.022, respectively. Conclusion: The 2 years' follow-up tests indicate that there is no significant difference between the above-mentioned parameters of the elaborately adjusted home X-ray machines and imported ones, but the home X-ray machines are no better than the imported X-ray machines in stability and consistency

  3. SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Abouei, E; Ford, N [University of British Columbia, Vancouver, BC (Canada)

    2014-06-01

    Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJ to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm{sup 2}) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty of

  4. SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

    International Nuclear Information System (INIS)

    Abouei, E; Ford, N

    2014-01-01

    Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJ to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm 2 ) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty of Dentistry

  5. Characteristics of magnetic resonance imaging with partial flip angle and gradient field echo

    International Nuclear Information System (INIS)

    Hamada, Tatsumi; Uto, Tatsurou; Okafuji, Tatsumasa; Ookusa, Akihiko; Oonishi, Takuya; Mabuchi, Nobuhisa; Fujii, Kouichi; Yoshioka, Hiroyasu; Ishida, Osamu

    1988-01-01

    Characteristics of a magnetic resonance (MR) imaging pulse sequence with short repetition time (Tr), short echo time (Te), partial flip angle and gradient field echo, at 0.5 T, were studied. A series of sagittal images of the cerebrospinal region was obtained with varied Tr, Te and flip angle, signal intensities were measured by means of a region of interest (ROI) function, and optimal parameters to achieve maximum tissue contrast were found. Of the parameters flip angle had the greatest effect on tissue contrast. Flip angles less than 20 or more than 60 degrees were necessary to discriminate between spinal cord and cerebrospinal fluid. So called MR myelography was obtained with the flip angle of 15 degrees. Opposed and inphase images were obtained at the Te levels of 21 and 28 ms, respectively. Likewise, a series of transverse images of the abdomen with short Tr, short Te and varied flip angles was obtained in a breath-holding interval, and signal intensities of ROIs were measured. Maximum intensities of the liver, the spleen and perirenal fat were obtained at the flip angles of 40, 30 and 60 degrees, respectively. Although maximum intensity was found at the flip angle of 30 degrees for both of the renal cortex and medulla, the maximum contrast between the two tissues was obtained at the flip angles of 50-60 degrees. The image contrast obtained by these pulse sequences was also theoretically predictable, and so it is thought possible that flip angle, Tr and Te are manipulated to yield a desired contrast. (author)

  6. Partial differential equation-based approach for empirical mode decomposition: application on image analysis.

    Science.gov (United States)

    Niang, Oumar; Thioune, Abdoulaye; El Gueirea, Mouhamed Cheikh; Deléchelle, Eric; Lemoine, Jacques

    2012-09-01

    The major problem with the empirical mode decomposition (EMD) algorithm is its lack of a theoretical framework. So, it is difficult to characterize and evaluate this approach. In this paper, we propose, in the 2-D case, the use of an alternative implementation to the algorithmic definition of the so-called "sifting process" used in the original Huang's EMD method. This approach, especially based on partial differential equations (PDEs), was presented by Niang in previous works, in 2005 and 2007, and relies on a nonlinear diffusion-based filtering process to solve the mean envelope estimation problem. In the 1-D case, the efficiency of the PDE-based method, compared to the original EMD algorithmic version, was also illustrated in a recent paper. Recently, several 2-D extensions of the EMD method have been proposed. Despite some effort, 2-D versions for EMD appear poorly performing and are very time consuming. So in this paper, an extension to the 2-D space of the PDE-based approach is extensively described. This approach has been applied in cases of both signal and image decomposition. The obtained results confirm the usefulness of the new PDE-based sifting process for the decomposition of various kinds of data. Some results have been provided in the case of image decomposition. The effectiveness of the approach encourages its use in a number of signal and image applications such as denoising, detrending, or texture analysis.

  7. Magnetic Resonance Imaging Findings in Symptomatic Patients After Arthroscopic Partial Meniscectomy for Torn Discoid Lateral Meniscus.

    Science.gov (United States)

    Lee, Chang-Rack; Bin, Seong-Il; Kim, Jong-Min; Kim, Nam-Ki

    2016-11-01

    To evaluate the change in the thickness and width of the residual meniscus using magnetic resonance imaging (MRI) in patients who underwent arthroscopic partial meniscectomy for discoid lateral meniscus (DLM), to assess whether the degeneration of the articular cartilage in the lateral compartment of the knee progressed, and to evaluate clinical results. Among the patients who underwent arthroscopic partial meniscectomy for DLM between January 1997 and December 2011, those who were aged 40 or below at surgery were followed up for at least 3 years, and received at least 2 follow-up MRIs that were retrospectively reviewed. MRIs were done in symptomatic knees. Using MRI, the relative thickness and width were measured in the anterior horn, midportion, and posterior horn. To determine whether the degeneration of the lateral compartment would progress, the articular cartilage was graded based on the Outerbridge classification in MRIs. The clinical results were evaluated using the Lysholm score. A total of 20 patients (21 knees) were included. The average follow-up period was 6.8 years. In residual meniscus, the relative thickness of the midportion decreased from 9.0% ± 2.4% to 7.3% ± 2.3% (P meniscus. A progression of degeneration in the lateral compartment was observed. However, the clinical results did not present significant changes. In symptomatic patients after arthroscopic partial meniscectomy for DLM, the thickness and width of the residual meniscus decreases over time. The arthritic change of the lateral compartment of the knee progressed. However, the change in the size of the residual meniscus was of unknown clinical significance. Level IV, therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Edge-augmented Fourier partial sums with applications to Magnetic Resonance Imaging (MRI)

    Science.gov (United States)

    Larriva-Latt, Jade; Morrison, Angela; Radgowski, Alison; Tobin, Joseph; Iwen, Mark; Viswanathan, Aditya

    2017-08-01

    Certain applications such as Magnetic Resonance Imaging (MRI) require the reconstruction of functions from Fourier spectral data. When the underlying functions are piecewise-smooth, standard Fourier approximation methods suffer from the Gibbs phenomenon - with associated oscillatory artifacts in the vicinity of edges and an overall reduced order of convergence in the approximation. This paper proposes an edge-augmented Fourier reconstruction procedure which uses only the first few Fourier coefficients of an underlying piecewise-smooth function to accurately estimate jump information and then incorporate it into a Fourier partial sum approximation. We provide both theoretical and empirical results showing the improved accuracy of the proposed method, as well as comparisons demonstrating superior performance over existing state-of-the-art sparse optimization-based methods.

  9. Factors Affecting Infants’ Manual Search for Occluded Objects and the Genesis of Object Permanence

    Science.gov (United States)

    Moore, M. Keith; Meltzoff, Andrew N.

    2009-01-01

    Two experiments systematically examined factors that influence infants’ manual search for hidden objects (N = 96). Experiment 1 used a new procedure to assess infants’ search for partially versus totally occluded objects. Results showed that 8.75-month-old infants solved partial occlusions by removing the occluder and uncovering the object, but these same infants failed to use this skill on total occlusions. Experiment 2 used sound-producing objects to provide a perceptual clue to the objects’ hidden location. Sound clues significantly increased the success rate on total occlusions for 10-month-olds, but not for 8.75-month-olds. An identity development account is offered for why infants succeed on partial occlusions earlier than total occlusions and why sound helps only the older infants. We propose a mechanism for how infants use object identity as a basis for developing a notion of permanence. Implications are drawn for understanding the dissociation between looking-time and search assessments of object permanence. PMID:18036668

  10. Factors affecting infants' manual search for occluded objects and the genesis of object permanence.

    Science.gov (United States)

    Moore, M Keith; Meltzoff, Andrew N

    2008-04-01

    Two experiments systematically examined factors that influence infants' manual search for hidden objects (N=96). Experiment 1 used a new procedure to assess infants' search for partially versus totally occluded objects. Results showed that 8.75-month-old infants solved partial occlusions by removing the occluder and uncovering the object, but these same infants failed to use this skill on total occlusions. Experiment 2 used sound-producing objects to provide a perceptual clue to the objects' hidden location. Sound clues significantly increased the success rate on total occlusions for 10-month-olds, but not for 8.75-month-olds. An identity development account is offered for why infants succeed on partial occlusions earlier than total occlusions and why sound helps only the older infants. We propose a mechanism for how infants use object identity as a basis for developing a notion of permanence. Implications are drawn for understanding the dissociation between looking time and search assessments of object permanence.

  11. An Evaluation of Dynamic Partial Reconfiguration for Signal and Image Processing in Professional Electronics Applications

    Directory of Open Access Journals (Sweden)

    Aulagnier Denis

    2008-01-01

    Full Text Available Abstract Signal and image processing applications require a lot of computing resources. For low-volume applications like in professional electronics applications, FPGA are used in combination with DSP and GPP in order to reach the performances required by the product roadmaps. Nevertheless, FPGA designs are static, which raises a flexibility issue with new complex or software defined applications like software-defined radio (SDR. In this scope, dynamic partial reconfiguration (DPR is used to bring a virtualization layer upon the static hardware of FPGA. During the last decade, DPR has been widely studied in academia. Nevertheless, there are very few real applications using it, and therefore, there is a lack of feedback providing relevant issues to address in order to improve its applicability. This paper evaluates the interest and limitations when using DPR in professional electronics applications and provides guidelines to improve its applicability. It makes a fair evaluation based on experiments made on a set of signal and image processing applications. It identifies the missing elements of the design flow to use DPR in professional electronics applications. Finally, it introduces a fast reconfiguration manager providing an 84-time improvement compared to the vendor solution.

  12. Cardi-O-Fix duct occluder versus Amplatzer duct occluder for closure of patent ductus arteriosus.

    Science.gov (United States)

    Celebi, Ahmet; Demir, Ibrahim Halil; Saritaş, Türkay; Dedeoğlu, Reyhan; Yucel, Ilker Kemal; Demir, Fadli; Erdem, Abdullah

    2013-11-15

    We sought to investigate the safety, efficacy, and follow-up results of percutaneous patent ductus arteriosus (PDA) closure using the novel Cardi-O-Fix duct occluder (CDO), a device similar to but less expensive than the Amplatzer duct occluder (ADO). We also aimed to compare these two devices in terms of results. Between March 2005 and May 2012, 167 patients diagnosed with moderate-to-large PDA underwent transcatheter closure. ADO was used in 56 (33.5%) patients with a mean age of 8.1 ± 11.9 years (3.6 months-56 years), whereas CDO was used in 111 (66.5%) patients with a mean age of 12.6 ± 14.6 years (4.8 months-63 years). The narrowest PDA diameter, the used device diameter, procedure time, fluoroscopy time, and residual shunt rates were similar between the two groups. Procedural success rate was 100% in both groups. Although the residual shunt rate was higher in the CDO group immediately after the procedure, the difference was not statistically significant (12.6 vs. 8.9%; P = 0.3). There was no statistically significant difference between groups at discharge and during follow-up. No deaths occurred in any of the groups, and there were no differences in complication rates during the short- and mid-term follow-up periods (CDO 7/111 vs. ADO 5/56; P = 0.5 π). The CDO can be used for PDA closure because of its safety, effectiveness, and simplicity in use. It is available in bigger sizes and can be used in patients with large defects. According to our short- and mid-term findings, the results it yields are similar to those of the ADO; thus, it may be the preferred choice owing to its low cost and large size variability. Copyright © 2013 Wiley Periodicals, Inc.

  13. Partial volume effect estimation and correction in the aortic vascular wall in PET imaging

    International Nuclear Information System (INIS)

    Burg, S; Le Guludec, D; Dupas, A; Stute, S; Dieudonné, A; Huet, P; Buvat, I

    2013-01-01

    We evaluated the impact of partial volume effect (PVE) in the assessment of arterial diseases with 18 FDG PET. An anthropomorphic digital phantom enabling the modeling of aorta related diseases like atherosclerosis and arteritis was used. Based on this phantom, we performed GATE Monte Carlo simulations to produce realistic PET images with a known organ segmentation and ground truth activity values. Images corresponding to 15 different activity-concentration ratios between the aortic wall and the blood and to 7 different wall thicknesses were generated. Using the PET images, we compared the theoretical wall-to-blood activity-concentration ratios (WBRs) with the measured WBRs obtained with five measurement methods: (1) measurement made by a physician (Expert), (2) automated measurement supposed to mimic the physician measurements (Max), (3) simple correction based on a recovery coefficient (Max-RC), (4) measurement based on an ideal VOI segmentation (Mean-VOI) and (5) measurement corrected for PVE using an ideal geometric transfer matrix (GTM) method. We found that Mean-VOI WBRs values were strongly affected by PVE. WBRs obtained by the physician measurement, by the Max method and by the Max-RC method were more accurate than WBRs obtained with the Mean-VOI approach. However Expert, Max and Max-RC WBRs strongly depended on the wall thickness. Only the GTM corrected WBRs did not depend on the wall thickness. Using the GTM method, we obtained more reproducible ratio values that could be compared across wall thickness. Yet, the feasibility of the implementation of a GTM-like method on real data remains to be studied. (paper)

  14. Quantitative evaluation of temporal partial coherence using 3D Fourier transforms of through-focus TEM images

    International Nuclear Information System (INIS)

    Kimoto, Koji; Sawada, Hidetaka; Sasaki, Takeo; Sato, Yuta; Nagai, Takuro; Ohwada, Megumi; Suenaga, Kazu; Ishizuka, Kazuo

    2013-01-01

    We evaluate the temporal partial coherence of transmission electron microscopy (TEM) using the three-dimensional (3D) Fourier transform (FT) of through-focus images. Young's fringe method often indicates the unexpected high-frequency information due to non-linear imaging terms. We have already used the 3D FT of axial (non-tilted) through-focus images to reduce the effect of non-linear terms on the linear imaging term, and demonstrated the improvement of monochromated lower-voltage TEM performance [Kimoto et al., Ultramicroscopy 121 (2012) 31–39]. Here we apply the 3D FT method with intentionally tilted incidence to normalize various factors associated with a TEM specimen and an imaging device. The temporal partial coherence of two microscopes operated at 30, 60 and 80 kV is evaluated. Our method is applicable to such cases where the non-linear terms become more significant in lower acceleration voltage or aberration-corrected high spatial resolution TEM. - Highlights: • We assess the temporal partial coherence of TEM using a 3-dimensional (3D) Fourier transform (FT) of through-focus images. • We apply the 3D FT method with intentionally tilted incidence to normalize various factors associated with a TEM specimen and an imaging device. • The spatial frequency at which information transfer decreases to 1/e 2 (13.5%) is determined for two lower-voltage TEM systems

  15. Effects of heating on salt-occluded zeolite

    International Nuclear Information System (INIS)

    Lewis, M.A.; Hash, M.C.; Pereira, C.; Ackerman, J.P.

    1996-01-01

    The electrometallurgical treatment of spent nuclear fuel generates a waste stream of fission products in the electrolyte, LiCl-KCl eutectic salt. Argonne National Laboratory is developing a mineral waste form for this waste stream. The waste form consists of a composite formed by hot pressing salt-occluded zeolite and a glass binder. Pressing conditions must be judiciously chosen. For a given pressure, increasing temperatures and hold times give denser products but the zeolite is frequently converted to sodalite. Reducing the temperature or hold time leads to a porous zeolite composite. Therefore, conditions that affect the thermal stability of salt-occluded zeolite both with and without glass are being investigated in an ongoing study. The parameters varied in this stage of the work were heating time, temperature, salt loading, and glass content. The heat-treated samples were examined primarily by X-ray diffraction. Large variations were found in the rate at which salt-occluded zeolite converted to other phases such as nepheline, salt, and sodalite. The products depended on the initial salt loading. Heating times required for these transitions depended on the procedure and temperature used to prepare the salt-occluded zeolite. Mixtures of glass and zeolite reacted much faster than the pure salt-occluded zeolite and were almost always converted to sodalite

  16. A simple algorithm for subregional striatal uptake analysis with partial volume correction in dopaminergic PET imaging

    International Nuclear Information System (INIS)

    Lue Kunhan; Lin Hsinhon; Chuang Kehshih; Kao Chihhao, K.; Hsieh Hungjen; Liu Shuhsin

    2014-01-01

    In positron emission tomography (PET) of the dopaminergic system, quantitative measurements of nigrostriatal dopamine function are useful for differential diagnosis. A subregional analysis of striatal uptake enables the diagnostic performance to be more powerful. However, the partial volume effect (PVE) induces an underestimation of the true radioactivity concentration in small structures. This work proposes a simple algorithm for subregional analysis of striatal uptake with partial volume correction (PVC) in dopaminergic PET imaging. The PVC algorithm analyzes the separate striatal subregions and takes into account the PVE based on the recovery coefficient (RC). The RC is defined as the ratio of the PVE-uncorrected to PVE-corrected radioactivity concentration, and is derived from a combination of the traditional volume of interest (VOI) analysis and the large VOI technique. The clinical studies, comprising 11 patients with Parkinson's disease (PD) and 6 healthy subjects, were used to assess the impact of PVC on the quantitative measurements. Simulations on a numerical phantom that mimicked realistic healthy and neurodegenerative situations were used to evaluate the performance of the proposed PVC algorithm. In both the clinical and the simulation studies, the striatal-to-occipital ratio (SOR) values for the entire striatum and its subregions were calculated with and without PVC. In the clinical studies, the SOR values in each structure (caudate, anterior putamen, posterior putamen, putamen, and striatum) were significantly higher by using PVC in contrast to those without. Among the PD patients, the SOR values in each structure and quantitative disease severity ratings were shown to be significantly related only when PVC was used. For the simulation studies, the average absolute percentage error of the SOR estimates before and after PVC were 22.74% and 1.54% in the healthy situation, respectively; those in the neurodegenerative situation were 20.69% and 2

  17. Correction for Eddy Current-Induced Echo-Shifting Effect in Partial-Fourier Diffusion Tensor Imaging.

    Science.gov (United States)

    Truong, Trong-Kha; Song, Allen W; Chen, Nan-Kuei

    2015-01-01

    In most diffusion tensor imaging (DTI) studies, images are acquired with either a partial-Fourier or a parallel partial-Fourier echo-planar imaging (EPI) sequence, in order to shorten the echo time and increase the signal-to-noise ratio (SNR). However, eddy currents induced by the diffusion-sensitizing gradients can often lead to a shift of the echo in k-space, resulting in three distinct types of artifacts in partial-Fourier DTI. Here, we present an improved DTI acquisition and reconstruction scheme, capable of generating high-quality and high-SNR DTI data without eddy current-induced artifacts. This new scheme consists of three components, respectively, addressing the three distinct types of artifacts. First, a k-space energy-anchored DTI sequence is designed to recover eddy current-induced signal loss (i.e., Type 1 artifact). Second, a multischeme partial-Fourier reconstruction is used to eliminate artificial signal elevation (i.e., Type 2 artifact) associated with the conventional partial-Fourier reconstruction. Third, a signal intensity correction is applied to remove artificial signal modulations due to eddy current-induced erroneous T2(∗) -weighting (i.e., Type 3 artifact). These systematic improvements will greatly increase the consistency and accuracy of DTI measurements, expanding the utility of DTI in translational applications where quantitative robustness is much needed.

  18. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    Science.gov (United States)

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally

  19. 99Tcm brain imaging for the assessment of patients with intractable partial epilepsy - our experience

    International Nuclear Information System (INIS)

    Schlicht, S.; Bruns, M.; Booth, R.; Octigan, K.; Karamoskos, P.; Cook, M.; O'Brien, T.

    2000-01-01

    Full text: 99 Tc m - Ethyl Cysteinate Diethylester (ECD) or Bicisate is a new radiopharmaceutical used for the assessment of cerebral perfusion. Unlike 99 Tc m Hexamethylpropylene Amine Oxime ( 99 Tc m - HMPAO) which is unstable and needs to be reconstituted immediately prior to injection, 99 Tc m -ECD is stable for up to eight hours following reconstitution. Therefore, 99 Tc m -ECD does not require mixing just prior to injection and is readily available on a daily inpatient basis to the epilepsy unit, facilitating earlier and faster injections, and the acquisition of true ictal studies. This is particularly important with patients who have extra temporal seizures which are typically brief in duration. 45 patients have undergone 99 Tc m -ECD studies for epilepsy in our department over a period of one year. Image acquisition routinely commences within two hours of injection, and consists of a 360 degree elliptical SPECT using an ADAC Dual Headed Gamma Camera. Patients undergo both ictal and inter ictal SPECT studies, and an MRI. Visual comparison of the ictal, inter ictal and MRI images is performed, as well as subtraction and co-registration. The SISCOM analysis technique is used which allows subtraction of the SPECTs and co registration with MRI. This has the advantage of improved specificity, sensitivity, and accurate anatomical localisation. The results of our experience with 99Tcm-ECD will be presented. In conclusion, we have found that 99 Tc m -ECD is ideally suited for peri-ictal SPECT studies as part of the pre-operative assessment of patients with intractable partial epilepsy. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  20. Ictal and interictal SPECT imaging of 8 patients with symptomatic partial epilepsy

    International Nuclear Information System (INIS)

    Motooka, Hiromichi

    1993-01-01

    Although epileptic discharges such as spike, spike and wave complex, sharp wave, and sharp and wave complex can be recorded by interictal scalp electroencephalography (EEG) in many patients with epilepsy, recent studies have demonstrated that no epileptic discharges can be recorded by interictal and ictal scalp EEGs in some patients who clinically exhibit epileptic seizures. Accordingly scalp EEG is not always helpful for diagnosing epilepsy or identifying the epileptic foci in the brain in these patients. Recently, studies using single photon emission computed tomography (SPECT) have been performed for patients with epilepsy and evidence that epileptic foci can be identified by changes in the regional cerebral blood flow (rCBF) seen on SPECT scanning have been accumulated. In the present study, therefore, 8 patients with medically intractable partial seizures were simultaneously or independently investigated by the recordings of scalp EEG and SPECT scanning during the interictal and ictal period. N-isopropyl-p[ 123 I]-iodoamphetamine ( 123 I-IMP) was used for SPECT scanning for 7 patients and 99m Tc-d,l-hexamethyl-propyleneamineoxime ( 99m Tc-HMPAO) for 1 patient. An increase in rCBF (hyperperfusion) or decrease in rCBF (hypoperfusion) were found in 4 patients by interictal SPECT imaging and in all patients by ictal SPECT imaging although epileptic discharges were observed in 3 patients by interictal scalp EEG and 5 patients by ictal scalp EEG. The findings of the present study indicate that ictal SPECT scanning is more useful for diagnosing epilepsy and identifying the epileptic foci in the brain than ictal scalp EEG. (author)

  1. Chaos-based partial image encryption scheme based on linear fractional and lifting wavelet transforms

    Science.gov (United States)

    Belazi, Akram; Abd El-Latif, Ahmed A.; Diaconu, Adrian-Viorel; Rhouma, Rhouma; Belghith, Safya

    2017-01-01

    In this paper, a new chaos-based partial image encryption scheme based on Substitution-boxes (S-box) constructed by chaotic system and Linear Fractional Transform (LFT) is proposed. It encrypts only the requisite parts of the sensitive information in Lifting-Wavelet Transform (LWT) frequency domain based on hybrid of chaotic maps and a new S-box. In the proposed encryption scheme, the characteristics of confusion and diffusion are accomplished in three phases: block permutation, substitution, and diffusion. Then, we used dynamic keys instead of fixed keys used in other approaches, to control the encryption process and make any attack impossible. The new S-box was constructed by mixing of chaotic map and LFT to insure the high confidentiality in the inner encryption of the proposed approach. In addition, the hybrid compound of S-box and chaotic systems strengthened the whole encryption performance and enlarged the key space required to resist the brute force attacks. Extensive experiments were conducted to evaluate the security and efficiency of the proposed approach. In comparison with previous schemes, the proposed cryptosystem scheme showed high performances and great potential for prominent prevalence in cryptographic applications.

  2. Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry

    Directory of Open Access Journals (Sweden)

    Akbar Fotouhi

    2013-08-01

    Full Text Available METHODS:As part of the first phase of Shahroud Eye Cohort Study with 5 190 subjects of 40 to 64 years of age, CCT and ACD were measured using Scheimpflug imaging with the Pentacam (Oculus, Inc., Lynnwood, WA, USA and partial coherence interferometry with the Allegro BioGraph (Wavelight, Erlangen, Germany.RESULTS:After applying exclusion criteria, we had data of 4 387 subjects with a mean age of 50.7±6.2 years. Mean CCT with Pentacam and BioGraph were 528.6±33.2μm and 525.6±32μm respectively; the difference was statistically significant (PPCONCLUSION:For both CCT and ACD, the BioGraph gave significantly lower values than the Pentacam (P<0.05. Despite the high inter-device correlation, the 95% limits of agreements were wide, and this may limit their interchangeability in measuring the CCT and ACD.

  3. Continuous partial status cause of hyperintensity in cerebral cortex in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Lopez L, Ingeborg; Gonzalez L, Daniela; Quezada R, Patricio; Cartier R, Luis

    2012-01-01

    Magnetic Resonance Imaging has demonstrated functional changes of the cerebral cortex in relation to status epilepticus, which can eventually localize the origin of the crisis. The purpose of this presentation is relevant to this condition and pretends to highlight the action of incidental situations that can modify it. We present a 29 year old woman with a neurosurgical intervention for a neuroblastoma irradiated fifteen years ago, which incidentally starts a continuous partial status epilepticus, expressed by clonies of the face and left limbs associated with functional impotence, resistant to oral therapy. Faced with the suspicion of recurrence of the tumor, a brain MRI is performed, showing hyperintensity of all neural areas the right hemisphere, with no evidence of tumor recurrence. Once submitted the status epilepticus, the hyperintensity disappeared in the hemisphere. This extensive reaction of the neural structures might be related to a permanent effect of radiation, which may have caused a mismatch functional glia, of the blood-brain barrier and interneural network

  4. Symmetric geometric transfer matrix partial volume correction for PET imaging: principle, validation and robustness

    Science.gov (United States)

    Sattarivand, Mike; Kusano, Maggie; Poon, Ian; Caldwell, Curtis

    2012-11-01

    Limited spatial resolution of positron emission tomography (PET) often requires partial volume correction (PVC) to improve the accuracy of quantitative PET studies. Conventional region-based PVC methods use co-registered high resolution anatomical images (e.g. computed tomography (CT) or magnetic resonance images) to identify regions of interest. Spill-over between regions is accounted for by calculating regional spread functions (RSFs) in a geometric transfer matrix (GTM) framework. This paper describes a new analytically derived symmetric GTM (sGTM) method that relies on spill-over between RSFs rather than between regions. It is shown that the sGTM is mathematically equivalent to Labbe's method; however it is a region-based method rather than a voxel-based method and it avoids handling large matrices. The sGTM method was validated using two three-dimensional (3D) digital phantoms and one physical phantom. A 3D digital sphere phantom with sphere diameters ranging from 5 to 30 mm and a sphere-to-background uptake ratio of 3-to-1 was used. A 3D digital brain phantom was used with four different anatomical regions and a background region with different activities assigned to each region. A physical sphere phantom with the same geometry and uptake as the digital sphere phantom was manufactured and PET-CT images were acquired. Using these three phantoms, the performance of the sGTM method was assessed against that of the GTM method in terms of accuracy, precision, noise propagation and robustness. The robustness was assessed by applying mis-registration errors and errors in estimates of PET point spread function (PSF). In all three phantoms, the results showed that the sGTM method has accuracy similar to that of the GTM method and within 5%. However, the sGTM method showed better precision and noise propagation than the GTM method, especially for spheres smaller than 13 mm. Moreover, the sGTM method was more robust than the GTM method when mis-registration errors or

  5. Symmetric geometric transfer matrix partial volume correction for PET imaging: principle, validation and robustness

    International Nuclear Information System (INIS)

    Sattarivand, Mike; Caldwell, Curtis; Kusano, Maggie; Poon, Ian

    2012-01-01

    Limited spatial resolution of positron emission tomography (PET) often requires partial volume correction (PVC) to improve the accuracy of quantitative PET studies. Conventional region-based PVC methods use co-registered high resolution anatomical images (e.g. computed tomography (CT) or magnetic resonance images) to identify regions of interest. Spill-over between regions is accounted for by calculating regional spread functions (RSFs) in a geometric transfer matrix (GTM) framework. This paper describes a new analytically derived symmetric GTM (sGTM) method that relies on spill-over between RSFs rather than between regions. It is shown that the sGTM is mathematically equivalent to Labbe's method; however it is a region-based method rather than a voxel-based method and it avoids handling large matrices. The sGTM method was validated using two three-dimensional (3D) digital phantoms and one physical phantom. A 3D digital sphere phantom with sphere diameters ranging from 5 to 30 mm and a sphere-to-background uptake ratio of 3-to-1 was used. A 3D digital brain phantom was used with four different anatomical regions and a background region with different activities assigned to each region. A physical sphere phantom with the same geometry and uptake as the digital sphere phantom was manufactured and PET-CT images were acquired. Using these three phantoms, the performance of the sGTM method was assessed against that of the GTM method in terms of accuracy, precision, noise propagation and robustness. The robustness was assessed by applying mis-registration errors and errors in estimates of PET point spread function (PSF). In all three phantoms, the results showed that the sGTM method has accuracy similar to that of the GTM method and within 5%. However, the sGTM method showed better precision and noise propagation than the GTM method, especially for spheres smaller than 13 mm. Moreover, the sGTM method was more robust than the GTM method when mis-registration errors or

  6. 3D early embryogenesis image filtering by nonlinear partial differential equations.

    Science.gov (United States)

    Krivá, Z; Mikula, K; Peyriéras, N; Rizzi, B; Sarti, A; Stasová, O

    2010-08-01

    We present nonlinear diffusion equations, numerical schemes to solve them and their application for filtering 3D images obtained from laser scanning microscopy (LSM) of living zebrafish embryos, with a goal to identify the optimal filtering method and its parameters. In the large scale applications dealing with analysis of 3D+time embryogenesis images, an important objective is a correct detection of the number and position of cell nuclei yielding the spatio-temporal cell lineage tree of embryogenesis. The filtering is the first and necessary step of the image analysis chain and must lead to correct results, removing the noise, sharpening the nuclei edges and correcting the acquisition errors related to spuriously connected subregions. In this paper we study such properties for the regularized Perona-Malik model and for the generalized mean curvature flow equations in the level-set formulation. A comparison with other nonlinear diffusion filters, like tensor anisotropic diffusion and Beltrami flow, is also included. All numerical schemes are based on the same discretization principles, i.e. finite volume method in space and semi-implicit scheme in time, for solving nonlinear partial differential equations. These numerical schemes are unconditionally stable, fast and naturally parallelizable. The filtering results are evaluated and compared first using the Mean Hausdorff distance between a gold standard and different isosurfaces of original and filtered data. Then, the number of isosurface connected components in a region of interest (ROI) detected in original and after the filtering is compared with the corresponding correct number of nuclei in the gold standard. Such analysis proves the robustness and reliability of the edge preserving nonlinear diffusion filtering for this type of data and lead to finding the optimal filtering parameters for the studied models and numerical schemes. Further comparisons consist in ability of splitting the very close objects which

  7. Simulation-based partial volume correction for dopaminergic PET imaging. Impact of segmentation accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Rong, Ye; Winz, Oliver H. [University Hospital Aachen (Germany). Dept. of Nuclear Medicine; Vernaleken, Ingo [University Hospital Aachen (Germany). Dept. of Psychiatry, Psychotherapy and Psychosomatics; Goedicke, Andreas [University Hospital Aachen (Germany). Dept. of Nuclear Medicine; High Tech Campus, Philips Research Lab., Eindhoven (Netherlands); Mottaghy, Felix M. [University Hospital Aachen (Germany). Dept. of Nuclear Medicine; Maastricht University Medical Center (Netherlands). Dept. of Nuclear Medicine; Rota Kops, Elena [Forschungszentrum Juelich (Germany). Inst. of Neuroscience and Medicine-4

    2015-07-01

    Partial volume correction (PVC) is an essential step for quantitative positron emission tomography (PET). In the present study, PVELab, a freely available software, is evaluated for PVC in {sup 18}F-FDOPA brain-PET, with a special focus on the accuracy degradation introduced by various MR-based segmentation approaches. Methods Four PVC algorithms (M-PVC; MG-PVC; mMG-PVC; and R-PVC) were analyzed on simulated {sup 18}F-FDOPA brain-PET images. MR image segmentation was carried out using FSL (FMRIB Software Library) and SPM (Statistical Parametric Mapping) packages, including additional adaptation for subcortical regions (SPM{sub L}). Different PVC and segmentation combinations were compared with respect to deviations in regional activity values and time-activity curves (TACs) of the occipital cortex (OCC), caudate nucleus (CN), and putamen (PUT). Additionally, the PVC impact on the determination of the influx constant (K{sub i}) was assessed. Results Main differences between tissue-maps returned by three segmentation algorithms were found in the subcortical region, especially at PUT. Average misclassification errors in combination with volume reduction was found to be lowest for SPM{sub L} (PUT < 30%) and highest for FSL (PUT > 70%). Accurate recovery of activity data at OCC is achieved by M-PVC (apparent recovery coefficient varies between 0.99 and 1.10). The other three evaluated PVC algorithms have demonstrated to be more suitable for subcortical regions with MG-PVC and mMG-PVC being less prone to the largest tissue misclassification error simulated in this study. Except for M-PVC, quantification accuracy of K{sub i} for CN and PUT was clearly improved by PVC. Conclusions The regional activity value of PUT was appreciably overcorrected by most of the PVC approaches employing FSL or SPM segmentation, revealing the importance of accurate MR image segmentation for the presented PVC framework. The selection of a PVC approach should be adapted to the anatomical

  8. A Virtual Reality System for PTCD Simulation Using Direct Visuo-Haptic Rendering of Partially Segmented Image Data.

    Science.gov (United States)

    Fortmeier, Dirk; Mastmeyer, Andre; Schröder, Julian; Handels, Heinz

    2016-01-01

    This study presents a new visuo-haptic virtual reality (VR) training and planning system for percutaneous transhepatic cholangio-drainage (PTCD) based on partially segmented virtual patient models. We only use partially segmented image data instead of a full segmentation and circumvent the necessity of surface or volume mesh models. Haptic interaction with the virtual patient during virtual palpation, ultrasound probing and needle insertion is provided. Furthermore, the VR simulator includes X-ray and ultrasound simulation for image-guided training. The visualization techniques are GPU-accelerated by implementation in Cuda and include real-time volume deformations computed on the grid of the image data. Computation on the image grid enables straightforward integration of the deformed image data into the visualization components. To provide shorter rendering times, the performance of the volume deformation algorithm is improved by a multigrid approach. To evaluate the VR training system, a user evaluation has been performed and deformation algorithms are analyzed in terms of convergence speed with respect to a fully converged solution. The user evaluation shows positive results with increased user confidence after a training session. It is shown that using partially segmented patient data and direct volume rendering is suitable for the simulation of needle insertion procedures such as PTCD.

  9. A comparative study assessing a new tool for occluding ...

    African Journals Online (AJOL)

    0.630, p=0.068 and p=0.047, respectively) (Table 2). A comparative study assessing a new tool for occluding parenchymal blood flow during liver resection for hepatocellular carcinoma. S Zhou, X-J Xue, R-R Li, D-F Chen, W-Y Chen, G-X Liu, ...

  10. Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Gholipour, Ali, E-mail: ali.gholipour@childrens.harvard.edu; Afacan, Onur; Scherrer, Benoit; Prabhu, Sanjay P.; Warfield, Simon K. [Department of Radiology, Boston Children’s Hospital, Boston, Massachusetts 02115 and Harvard Medical School, Boston, Massachusetts 02115 (United States); Aganj, Iman [Radiology Department, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts 02129 and Harvard Medical School, Boston, Massachusetts 02115 (United States); Sahin, Mustafa [Department of Neurology, Boston Children’s Hospital, Boston, Massachusetts 02115 and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2015-12-15

    Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in

  11. Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

    International Nuclear Information System (INIS)

    Gholipour, Ali; Afacan, Onur; Scherrer, Benoit; Prabhu, Sanjay P.; Warfield, Simon K.; Aganj, Iman; Sahin, Mustafa

    2015-01-01

    Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in

  12. Phase-and-amplitude recovery from a single phase-contrast image using partially spatially coherent x-ray radiation

    Science.gov (United States)

    Beltran, Mario A.; Paganin, David M.; Pelliccia, Daniele

    2018-05-01

    A simple method of phase-and-amplitude extraction is derived that corrects for image blurring induced by partially spatially coherent incident illumination using only a single intensity image as input. The method is based on Fresnel diffraction theory for the case of high Fresnel number, merged with the space-frequency description formalism used to quantify partially coherent fields and assumes the object under study is composed of a single-material. A priori knowledge of the object’s complex refractive index and information obtained by characterizing the spatial coherence of the source is required. The algorithm was applied to propagation-based phase-contrast data measured with a laboratory-based micro-focus x-ray source. The blurring due to the finite spatial extent of the source is embedded within the algorithm as a simple correction term to the so-called Paganin algorithm and is also numerically stable in the presence of noise.

  13. Comparison of CsI(Tl) and CsI(Na) partially slotted crystals for high-resolution SPECT imaging

    International Nuclear Information System (INIS)

    Giokaris, N.; Loudos, G.; Maintas, D.; Karabarbounis, A.; Lembesi, M.; Spanoudaki, V.; Stiliaris, E.; Boukis, S.; Sakellios, N.; Karakatsanis, N.; Gektin, A.; Boyarintsev, A.; Pedash, V.; Gayshan, V.

    2006-01-01

    Dedicated systems based on Position Sensitive Photomultiplier Tubes (PSPMTs) coupled to scintillators, have been used over the past years for the construction of compact systems, suitable for applications such as small animal imaging and small organs imaging. Most of the proposed systems are based on fully pixelized scintillators. Previous studies have shown that partially slotted scintillators offer a good compromise between cost, energy resolution and spatial resolution. In this work, the performance of two sets of CsI(Tl) and CsI(Na) partially slotted crystals is compared. Initial results show that CsI(Tl) scintillators are more suitable for gamma-ray detection, since their performance in terms of sensitivity, spatial and energy resolution is superior than that of CsI(Na)

  14. Combustion stratification study of partially premixed combustion using Fourier transform analysis of OH* chemiluminescence images

    KAUST Repository

    Izadi Najafabadi, Mohammad; Somers, Bart; Johansson, Bengt; Dam, Nico

    2017-01-01

    A relatively high level of stratification (qualitatively: lack of homogeneity) is one of the main advantages of partially premixed combustion over the homogeneous charge compression ignition concept. Stratification can smooth the heat release rate

  15. Simultaneous imaging of cerebral partial pressure of oxygen and blood flow during functional activation and cortical spreading depression

    Science.gov (United States)

    Sakadžić, Sava; Yuan, Shuai; Dilekoz, Ergin; Ruvinskaya, Svetlana; Vinogradov, Sergei A.; Ayata, Cenk; Boas, David A.

    2009-01-01

    We developed a novel imaging technique that provides real-time two-dimensional maps of the absolute partial pressure of oxygen and relative cerebral blood flow in rats by combining phosphorescence lifetime imaging with laser speckle contrast imaging. Direct measurement of blood oxygenation based on phosphorescence lifetime is not significantly affected by changes in the optical parameters of the tissue during the experiment. The potential of the system as a novel tool for quantitative analysis of the dynamic delivery of oxygen to support brain metabolism was demonstrated in rats by imaging cortical responses to forepaw stimulation and the propagation of cortical spreading depression waves. This new instrument will enable further study of neurovascular coupling in normal and diseased brain. PMID:19340106

  16. Value of 3.0 T MR imaging in refractory partial epilepsy and negative 1.5 T MRI.

    Science.gov (United States)

    Nguyen, Dang Khoa; Rochette, Emilie; Leroux, Jean-Maxime; Beaudoin, Gilles; Cossette, Patrick; Lassonde, Maryse; Guilbert, François

    2010-10-01

    High-field 3.0 T MR scanners provide an improved signal-to-noise ratio which can be translated in higher image resolution, possibly allowing critical detection of subtle epileptogenic lesions missed on standard-field 1.0-1.5 T MRIs. In this study, the authors explore the potential value of re-imaging at 3.0 T patients with refractory partial epilepsy and negative 1.5 T MRI. We retrospectively identified all patients with refractory partial epilepsy candidate for surgery who had undergone a 3.0 T MR study after a negative 1.5 T MR study. High-field 3.0 T MRIs were reviewed qualitatively by neuroradiologists experienced in interpreting epilepsy studies with access to clinical information. Relevance and impact on clinical management were assessed by an epileptologist. Between November 2006 and August 2009, 36 patients with refractory partial epilepsy candidate for surgery underwent 3.0 T MR study after a 1.5 T MR study failed to disclose a relevant epileptogenic lesion. A potential lesion was found only in two patients (5.6%, 95% CI: 1.5-18.1%). Both were found to have hippocampal atrophy congruent with other presurgical localization techniques which resulted in omission of an invasive EEG study and direct passage to surgery. The frequency of detection of a new lesion by re-imaging at 3.0 T patients with refractory partial epilepsy candidate for surgery was found to be low, but seems to offer the potential of a significant clinical impact for selected patients. This finding needs to be validated in a prospective controlled study. Copyright © 2010 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  17. Unconventional uses of septal occluder devices: Our experience reviewed

    Directory of Open Access Journals (Sweden)

    Neeraj Awasthy

    2015-03-01

    Conclusion: It is feasible in selected nonseptal defects, which traditionally have been subjected to surgical interventions, to treat successfully, non surgically with the use of non prototype occluder devices without significant complications. Conventionally these devices have not been recommended for closure of nonseptal defects but show good early outcome. Adequate sample size with good follow up data is necessary before concluding that it can be safe alternative to surgery on long term.

  18. Prototype volumetric ultrasound tomography image guidance system for prone stereotactic partial breast irradiation: proof-of-concept

    Science.gov (United States)

    Chiu, Tsuicheng D.; Parsons, David; Zhang, Yue; Hrycushko, Brian; Zhao, Bo; Chopra, Rajiv; Kim, Nathan; Spangler, Ann; Rahimi, Asal; Timmerman, Robert; Jiang, Steve B.; Lu, Weiguo; Gu, Xuejun

    2018-03-01

    Accurate dose delivery in stereotactic partial breast irradiation (S-PBI) is challenging because of the target position uncertainty caused by breast deformation, the target volume changes caused by lumpectomy cavity shrinkage, and the target delineation uncertainty on simulation computed tomography (CT) images caused by poor soft tissue contrast. We have developed a volumetric ultrasound tomography (UST) image guidance system for prone position S-PBI. The system is composed of a novel 3D printed rotation water tank, a patient-specific resin breast immobilization cup, and a 1D array ultrasound transducer. Coronal 2D US images were acquired in 5° increments over a 360° range, and planes were acquired every 2 mm in elevation. A super-compounding technique was used to reconstruct the image volume. The image quality of UST was evaluated with a BB-1 breast phantom and BioZorb surgical marker, and the results revealed that UST offered better soft tissue contrast than CT and similar image quality to MR. In the evaluated plane, the size and location of five embedded objects were measured and compared to MR, which is considered as the ground truth. Objects’ diameters and the distances between objects in UST differ by approximately 1 to 2 mm from those in MR, which showed that UST offers the image quality required for S-PBI. In future work we will develop a robotic system that will be ultimately implemented in the clinic.

  19. Mass transport and chloride ion complexes in occluded cell

    International Nuclear Information System (INIS)

    Tsuru, T.; Hashimoto, K.; Nishikata, A.; Haruyama, S.

    1989-01-01

    Changes in the transport and the concentration of ions in a model occluded cell are traced during galvanostatic anodic polarization of a mild steel and a stainless steel. Apparent transport numbers of anions and cations, which were estimated from chemical analysis of solution, were different from those calculated from known mobility data. At the initial stage of the polarization, the transport number of chloride ion was almost unity, and then decreased gradually. For the mild steel, the concentration of total chloride ion accumulated in the occluded compartment increased with the anodic charge passed, and the amount of chloride ion complexed with cations also increased. The chloride complex was estimated as FeCl + . For SUS304 stainless steel, the total chloride ion increased, however, the free chloride ion, which responded to an Ag/AgCl electrode remained approximately 2 mol/dm 3 . Therefore, most of the chloride ions transferred into the occluded cell formed complex ions, such as CrCl n 3-n . The number of chloride ion coordinated to ferrous and chromic ions was estimated from the data fo mass transport for the case of the mild steel and the stainless steel. (author) 9 refs., 14 figs

  20. How does imaging frequency and soft tissue motion affect the PTV margin size in partial breast and boost radiotherapy?

    International Nuclear Information System (INIS)

    Harris, Emma J.; Donovan, Ellen M.; Coles, Charlotte E.; Boer, Hans C.J. de; Poynter, Andrew; Rawlings, Christine; Wishart, Gordon C.; Evans, Philip M.

    2012-01-01

    Purpose: This study investigates (i) the effect of verification protocols on treatment accuracy and PTV margins for partial breast and boost breast radiotherapy with short fractionation schema (15 fractions), (ii) the effect of deformation of the excision cavity (EC) on PTV margin size, (iii) the imaging dose required to achieve specific PTV margins. Methods and materials: Verification images using implanted EC markers were studied in 36 patients. Target motion was estimated for a 15 fraction partial breast regimen using imaging protocols based on on-line and off-line motion correction strategies (No Action Level (NAL) and the extended NAL (eNAL) protocols). Target motion was used to estimate a PTV margin for each protocol. To evaluate treatment errors due to deformation of the excision cavity, individual marker positions were obtained from 11 patients. The mean clip displacement and daily variation in clip position during radiotherapy were determined and the contribution of these errors to PTV margin calculated. Published imaging dose data were used to estimate total dose for each protocol. Finally the number of images required to obtain a specific PTV margin was evaluated and hence, the relationship between PTV margins and imaging dose was investigated. Results: The PTV margin required to account for excision cavity motion, varied between 10.2 and 2.4 mm depending on the correction strategy used. Average clip movement was 0.8 mm and average variation in clip position during treatment was 0.4 mm. The contribution to PTV margin from deformation was estimated to be small, less than 0.2 mm for both off-line and on-line correction protocols. Conclusion: A boost or partial breast PTV margin of ∼10 mm, is possible with zero imaging dose and workload, however, patients receiving boost radiotherapy may benefit from a margin reduction of ∼4 mm with imaging doses from 0.4 cGy to 25 cGy using an eNAL protocol. PTV margin contributions from deformation errors are likely

  1. Non-contact measurement of partial gas pressure and distribution of elemental composition using energy-resolved neutron imaging

    Directory of Open Access Journals (Sweden)

    A. S. Tremsin

    2017-01-01

    Full Text Available Neutron resonance absorption imaging is a non-destructive technique that can characterize the elemental composition of a sample by measuring nuclear resonances in the spectrum of a transmitted beam. Recent developments in pixelated time-of-flight imaging detectors coupled with pulsed neutron sources pose new opportunities for energy-resolved imaging. In this paper we demonstrate non-contact measurements of the partial pressure of xenon and krypton gases encapsulated in a steel pipe while simultaneously passing the neutron beam through high-Z materials. The configuration was chosen as a proof of principle demonstration of the potential to make non-destructive measurement of gas composition in nuclear fuel rods. The pressure measured from neutron transmission spectra (∼739 ± 98 kPa and ∼751 ± 154 kPa for two Xe resonances is in relatively good agreement with the pressure value of ∼758 ± 21 kPa measured by a pressure gauge. This type of imaging has been performed previously for solids with a spatial resolution of ∼ 100 μm. In the present study it is demonstrated that the high penetration capability of epithermal neutrons enables quantitative mapping of gases encapsulate within high-Z materials such as steel, tungsten, urania and others. This technique may be beneficial for the non-destructive testing of bulk composition of objects (such as spent nuclear fuel assemblies and others containing various elements opaque to other more conventional imaging techniques. The ability to image the gaseous substances concealed within solid materials also allows non-destructive leak testing of various containers and ultimately measurement of gas partial pressures with sub-mm spatial resolution.

  2. Theoretical study of ghost imaging with cold atomic waves under the condition of partial coherence

    International Nuclear Information System (INIS)

    Chen, Jun; Liu, Yun-Xian

    2014-01-01

    A matter wave ghost imaging mechanism is proposed and demonstrated theoretically. This mechanism is based on the Talbot-Lau effect. Periodic gratings of matter wave density, which appear as a result of interference of atoms diffracted by pulses of an optical standing wave, are utilized to produce the reference wave and the signal wave simultaneously for the ghost imaging. An advantage of this mechanism is that during the imaging process, the beam-splitter is not needed, which highly simplifies the experimental setup and makes the ghost imaging possible in the field of matter wave

  3. Effective Five Directional Partial Derivatives-Based Image Smoothing and a Parallel Structure Design.

    Science.gov (United States)

    Choongsang Cho; Sangkeun Lee

    2016-04-01

    Image smoothing has been used for image segmentation, image reconstruction, object classification, and 3D content generation. Several smoothing approaches have been used at the pre-processing step to retain the critical edge, while removing noise and small details. However, they have limited performance, especially in removing small details and smoothing discrete regions. Therefore, to provide fast and accurate smoothing, we propose an effective scheme that uses a weighted combination of the gradient, Laplacian, and diagonal derivatives of a smoothed image. In addition, to reduce computational complexity, we designed and implemented a parallel processing structure for the proposed scheme on a graphics processing unit (GPU). For an objective evaluation of the smoothing performance, the images were linearly quantized into several layers to generate experimental images, and the quantized images were smoothed using several methods for reconstructing the smoothly changed shape and intensity of the original image. Experimental results showed that the proposed scheme has higher objective scores and better successful smoothing performance than similar schemes, while preserving and removing critical and trivial details, respectively. For computational complexity, the proposed smoothing scheme running on a GPU provided 18 and 16 times lower complexity than the proposed smoothing scheme running on a CPU and the L0-based smoothing scheme, respectively. In addition, a simple noise reduction test was conducted to show the characteristics of the proposed approach; it reported that the presented algorithm outperforms the state-of-the art algorithms by more than 5.4 dB. Therefore, we believe that the proposed scheme can be a useful tool for efficient image smoothing.

  4. MRI differential diagnosis of complete and partial tears of the anterior cruciate ligament of the knee: the usefulness of oblique coronal T2-weighted image

    International Nuclear Information System (INIS)

    Lee, Seo Young; Shim, Jae Chan; Lee, Ghi Jai; Bang, Sun Woo; Ryu, Seok Jong; Kim, Ho Kyun; Kim, Jeong Seok

    2002-01-01

    To assess the usefulness of T2-weighted oblique coronal MR imaging (T2OCI) in the differential diagnosis of complete and partial tears of the anterior cruciate ligament (ACL) of the knee. Thirty-three patients with ACL tear (16 complete and 17 partial tears), comfirmed by arthroscopy, were included in this study. Conventional MR imaging and T2OCI were performed, and the findings were retrospectively reviewed by two radiologists in terms of continuity, shape, axis and internal signal intensity of the ligament. Each finding was tested if there were stastistically significant differences in its prevalence between partial and complete tears. The diagnostic accuracy of T2OCI and conventional MR imaging in the detection of partial and complete tears of the ACL were compared. Conventional MR imaging revealed no statistically significant finding for differential diagnosis of complete and partial ACL tears. The reliable and statistically significant (p<0.001) findings of T2OCI were complete discontinuity of the ligament in cases involving complete ACL tears (14 of 16 complete tears and 2 of 17 partial tears) and the preservation of the band form for partial ACL tears (2 of 16 complete tears and 15 of 17 partial tears). The accuracy of T2OCI and conventional MR imaging was 88% and 70%, respectively. When ACL injury is vague on conventional MR images, a modality which is more useful in the differential diagnosis of partial and complete tears of the ACL, and in predicting the site of a tear, is T2-weighted oblique coronal imaging

  5. Recognition of Simple 3D Geometrical Objects under Partial Occlusion

    Science.gov (United States)

    Barchunova, Alexandra; Sommer, Gerald

    In this paper we present a novel procedure for contour-based recognition of partially occluded three-dimensional objects. In our approach we use images of real and rendered objects whose contours have been deformed by a restricted change of the viewpoint. The preparatory part consists of contour extraction, preprocessing, local structure analysis and feature extraction. The main part deals with an extended construction and functionality of the classifier ensemble Adaptive Occlusion Classifier (AOC). It relies on a hierarchical fragmenting algorithm to perform a local structure analysis which is essential when dealing with occlusions. In the experimental part of this paper we present classification results for five classes of simple geometrical figures: prism, cylinder, half cylinder, a cube, and a bridge. We compare classification results for three classical feature extractors: Fourier descriptors, pseudo Zernike and Zernike moments.

  6. Reconstruction strategy for echo planar spectroscopy and its application to partially undersampled imaging

    DEFF Research Database (Denmark)

    Hanson, L G; Schaumburg, K; Paulson, O B

    2000-01-01

    The most commonly encountered form of echo planar spectroscopy involves oscillating gradients in one spatial dimension during readout. Data are consequently not sampled on a Cartesian grid. A fast gridding algorithm applicable to this particular situation is presented. The method is optimal, i.......e., it performs as well as the full discrete Fourier transform for band limited signals while allowing for use of the fast Fourier transform. The method is demonstrated for reconstruction of data that are partially undersampled in the time domain. The advantages of undersampling are lower hardware requirements...

  7. Ultrasound imaging of partial hydatidiform mole in the second trimester of pregnancy

    International Nuclear Information System (INIS)

    Jover Labiste, Marina

    2012-01-01

    The case report of a 27 year-old patient with 18 weeks gestation, admitted to the Obstetrics Department of 'Mariana Grajales Coello' Provincial Gynecology and Obstetrics Hospital of Santiago de Cuba due to high blood pressure, cephalea and pain in lower abdomen is described. Additional tests confirmed a partial hydatidiform mole, so that uterine curettage was performed and small fragments of endometrial stroma were removed for pathological study. Outpatient medical monitoring was recommended and the patient had an appointment at 21 days for controlling and evaluating her general state

  8. Clinical Experience With Image-Guided Radiotherapy in an Accelerated Partial Breast Intensity-Modulated Radiotherapy Protocol

    International Nuclear Information System (INIS)

    Leonard, Charles E.; Tallhamer, Michael M.S.; Johnson, Tim; Hunter, Kari C.M.D.; Howell, Kathryn; Kercher, Jane; Widener, Jodi; Kaske, Terese; Paul, Devchand; Sedlacek, Scot; Carter, Dennis L.

    2010-01-01

    Purpose: To explore the feasibility of fiducial markers for the use of image-guided radiotherapy (IGRT) in an accelerated partial breast intensity modulated radiotherapy protocol. Methods and Materials: Nineteen patients consented to an institutional review board approved protocol of accelerated partial breast intensity-modulated radiotherapy with fiducial marker placement and treatment with IGRT. Patients (1 patient with bilateral breast cancer; 20 total breasts) underwent ultrasound guided implantation of three 1.2- x 3-mm gold markers placed around the surgical cavity. For each patient, table shifts (inferior/superior, right/left lateral, and anterior/posterior) and minimum, maximum, mean error with standard deviation were recorded for each of the 10 BID treatments. The dose contribution of daily orthogonal films was also examined. Results: All IGRT patients underwent successful marker placement. In all, 200 IGRT treatment sessions were performed. The average vector displacement was 4 mm (range, 2-7 mm). The average superior/inferior shift was 2 mm (range, 0-5 mm), the average lateral shift was 2 mm (range, 1-4 mm), and the average anterior/posterior shift was 3 mm (range, 1 5 mm). Conclusions: This study shows that the use of IGRT can be successfully used in an accelerated partial breast intensity-modulated radiotherapy protocol. The authors believe that this technique has increased daily treatment accuracy and permitted reduction in the margin added to the clinical target volume to form the planning target volume.

  9. X-ray imaging by partially coherent synchrotron light. Application to metallic alloys, tooth dentin and natural rock

    Energy Technology Data Exchange (ETDEWEB)

    Zabler, Simon Andreas

    2007-10-09

    The hard spectrum which is available on the BAMline at Berlin's synchrotron BESSY offers the rare opportunity to perform high-resolution X-ray imaging experiments with a partially coherent beam. This thesis work reports on the development of a new tomography system, including Fresnel-propagated imaging, and its application to three specific materials science problems from the fields of engineering materials, biology and earth science. Static and dynamic 2D and 3D images were recorded from a variety of aluminum-based alloys. Coarsening of particle agglomerates (at high solid volume fraction) in liquid solution, as well as rheological properties of semi-solid alloys are thus characterized. Dentin is characterized by a quasi-parallel arrangement of micrometer-sized tubules. This work shows how high-resolution 3D images of water-immersed tooth dentin are recorded, and detailed simulations of the optical wave propagation reveal that Fresnel-images contain additional information about the dense cuff of peritubular dentin surrounding the tubules. The cuff thickness can be extrapolated from the interference fringes that form the propagated images of tubules. Absorption and Fresnel-propagated X-ray tomography are applied to measure samples of different rocks before and after mechanical compression nondestructively. In a first approach, limestone and greywacke are investigated, representing two sedimentary rocks of different grain size. Basalt and granite are tested in a second approach to compare different rock types. Development of cracks is observed in all materials, leading to fracture when increasing mechanical load is applied. In this work, relatively small mm-sized samples are used in order to test a classical fracture model wherein micro-flaws initiate the formation of larger cracks. For the first time, Fresnel-propagated imaging is applied to rock samples, highlighting micrometer-sized intergranular porosity as well as different material phases. The latter is

  10. X-ray imaging by partially coherent synchrotron light. Application to metallic alloys, tooth dentin and natural rock

    International Nuclear Information System (INIS)

    Zabler, Simon Andreas

    2007-01-01

    The hard spectrum which is available on the BAMline at Berlin's synchrotron BESSY offers the rare opportunity to perform high-resolution X-ray imaging experiments with a partially coherent beam. This thesis work reports on the development of a new tomography system, including Fresnel-propagated imaging, and its application to three specific materials science problems from the fields of engineering materials, biology and earth science. Static and dynamic 2D and 3D images were recorded from a variety of aluminum-based alloys. Coarsening of particle agglomerates (at high solid volume fraction) in liquid solution, as well as rheological properties of semi-solid alloys are thus characterized. Dentin is characterized by a quasi-parallel arrangement of micrometer-sized tubules. This work shows how high-resolution 3D images of water-immersed tooth dentin are recorded, and detailed simulations of the optical wave propagation reveal that Fresnel-images contain additional information about the dense cuff of peritubular dentin surrounding the tubules. The cuff thickness can be extrapolated from the interference fringes that form the propagated images of tubules. Absorption and Fresnel-propagated X-ray tomography are applied to measure samples of different rocks before and after mechanical compression nondestructively. In a first approach, limestone and greywacke are investigated, representing two sedimentary rocks of different grain size. Basalt and granite are tested in a second approach to compare different rock types. Development of cracks is observed in all materials, leading to fracture when increasing mechanical load is applied. In this work, relatively small mm-sized samples are used in order to test a classical fracture model wherein micro-flaws initiate the formation of larger cracks. For the first time, Fresnel-propagated imaging is applied to rock samples, highlighting micrometer-sized intergranular porosity as well as different material phases. The latter is shown

  11. Subintimal Recanalization of Occluded Stents: The Substent Technique

    International Nuclear Information System (INIS)

    Diamantopoulos, Athanasios; Katsanos, Konstantinos; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris

    2013-01-01

    PurposeApplication of metal stents is complicated by neointimal hyperplasia leading to vessel restenosis and reocclusion. Treatment options in cases presenting with complete occlusion of the stented segment and recurrent critical limb ischemia (CLI) are limited. We present the option of the subintimal/substent technique in dealing with occluded stents.MethodsThe study included patients presenting with recurrent CLI due to impaired blood flow as a result of complete occlusion of previously inserted metal stents and unsuccessful intraluminal crossing of the lesion via either the antegrade or retrograde approach. In these cases, crossing the occlusion through the subintimal/substent plane was attempted. Primary end points included technical success, safety of the procedure, clinical improvement, and limb salvage, while secondary end points were patient survival, primary patency, and vessel restenosis rates at 1-year follow-up. Study end points were calculated by Kaplan–Meier survival analysis.ResultsBetween July 2006 and October 2011, a total of 14 patients (mean age 69.14 ± 12.59 years, 12 men) were treated with the substent technique and included in the analysis. Technical success rate was 85.71 % (12 of 14), with a total lesion length of 193.57 ± 90.78 mm. The mean occluded stented segment length was 90.21 ± 44.34 mm. In 10 (83.33 %) of 12 cases, a new stent had to be placed by the side of the old occluded one, while the remaining two cases (16.67 %) were treated only with balloon angioplasty. No serious adverse events were noted during the immediate postprocedural period. All successfully treated patients improved clinically. Estimated limb salvage was 90.9 %, and patient survival rate was 90.0 % at 1 year’s follow-up. Primary patency was 45.50 % and vessel restenosis 77.30 %.ConclusionSubintimal recanalization of occluded metal stents through the substent plane is a valuable alternative treatment option, especially in patients with recurrent CLI with few

  12. Magnetic resonance imaging appearance of partial latissimus dorsi muscle tendon tear

    International Nuclear Information System (INIS)

    Le, Huy B.Q.; Lee, Steven T.; Lane, Michael D.; Munk, Peter L.; Malfair, David; Blachut, Piotr A.

    2009-01-01

    There is still a paucity of information about the clinical presentation, treatment and imaging findings of latissimus muscle tears. Only one study has specifically described the magnetic resonance imaging (MRI) features of latissimus tendon tears. We describe a case of a high-grade tear in the latissimus muscle tendon in an active water skier with no significant prior medical history. MRI demonstrated at least a 50% tear of the latissimus tendon, manifesting as increased signal intensity on T2-weighted sequences and surrounding edema, as well as a diminutive tendon at the humeral insertion. (orig.)

  13. STUDY OF BIREFRINGENCE INFLUENCE ON IMAGE QUALITY OF PHOTOLITHOGRAPHY SYSTEMS IN VIEW OF PARTIALLY-COHERENT LIGHT SOURCE

    Directory of Open Access Journals (Sweden)

    E. A. Nikulina

    2015-03-01

    Full Text Available Subject of study. A vector model for conversion of electromagnetic radiation in optical systems is considered, taking into account the influence of birefringence, as well as partially coherent illumination. Model. The proposed model is based on the representation of the complex amplitude of the monochromatic field through thesuperposition of basic plane waves. Transmitted light image with partially coherent illumination is performed by the sourceintegration method. Main results. The results of simulation for the point spread function are demonstrating the level of the birefringence influence on the image quality. In the presence of the wave aberration about 0.098 of the wavelength, the wave energy loss in the center of the Airy disk with an average birefringence of 4 nm/cm was 8%, and at 16 nm/cm it reached 30%. The calculation of the point spread function for a real sample of fluorite is given. The central peak of the PSF without birefringence was 0.722, with regard to birefringence it was equal to 0.701. Practical significance. The findings can be used in the development of photolithographic lenses, as well as for the manufacturing of any other optical systems that require consideration of the polarization properties of the materials.

  14. Comparison of blind imaging performance of Fizeau and Michelson type arrays for a partially resolved object

    NARCIS (Netherlands)

    Van der Avoort, C.; Den Herder, J.W.; Braat, J.

    2005-01-01

    This paper compares two well-known types of interferometer arrays for optical aperture synthesis. An analytical model for both types describes the expected output, in terms of photon counts. The goal is to characterize the performance of both types of array for blind imaging of a wide-field or

  15. Prediction of beef marblingusing Hyperspectral Imaging (HSI and Partial Least Squares Regression (PLSR

    Directory of Open Access Journals (Sweden)

    Victor Aredo

    2017-01-01

    Full Text Available The aim of this study was to build a model to predict the beef marbling using HSI and Partial Least Squares Regression (PLSR. Totally 58 samples of longissmus dorsi muscle were scanned by a HSI system (400 - 1000 nm in reflectance mode, using 44 samples to build t he PLSR model and 14 samples to model validation. The Japanese Beef Marbling Standard (BMS was used as reference by 15 middle - trained judges for the samples evaluation. The scores were assigned as continuous values and varied from 1.2 to 5.3 BMS. The PLSR model showed a high correlation coefficient in the prediction (r = 0.95, a low Standard Error of Calibration (SEC of 0.2 BMS score, and a low Standard Error of Prediction (SEP of 0.3 BMS score.

  16. Role of I-123-iomazenil SPEDT imaging in drug resistant epilepsy with complex partial seizures

    Energy Technology Data Exchange (ETDEWEB)

    Sjoeholm, H.; Rosen, I.; Elmqvist, D. [Univ. Hospital, Dept. of Clinical Neurophysiology, Lund (Sweden)

    1995-07-01

    Fifteen patients with therapy resistant partial complex seizures with no structural lesions were examined interictally with 123-I-IOMAXENIL SPECT for measurement of benzodiazepine receptor distribution and with 99m-Tc-HMPAO SPEDT for measurement of cerebral blood flow distribution. Regional abnormalities were correlated with the seizure onset patterns in EEG later recorded with implanted subdural strips. SPECT scans were made immediately after and at 1 and 2 h after intravenous injection of 123-I-Iomaxenil. During that time there was a continuous change from an immediate flow-related distribution toward a more specific receptor distribution. The decay of radioactivity of I-123 in the brain was linear over time. Two patients on benzodiazepine treatment showed much faster elimination and showed no focal abnormalities. Eight patients with clear-cut unifocal seizure onset showed concordant focal benzodiazepine defects. These patients showed a progressive focus/homotopic non-focus enhancement over time much larger than the HMPAO scans in the same patients. Also the estimated focal area of abnormality was more restricted in the Iomazenil scans than in HMPAO scans. Five patients had more complex seizure onset patterns. In these patients a mismatch between the locations of abnormalities in Iomaxenil and HMPAO scans were often found but benzodiazepine receptor abnormalities were more circumscribed also in these patients. The results suggest that 123-I-Iomazenil SPECT is more useful than 99mTc-HMPAO SPECT when applied interictally in patients with partial complex epilepsy, since in addition to demonstrate the hemispheric laterality of the epileptogenic zone, 123-I-Iomazenil appears to indicate its anatomical location with higher confidence, which could be of practical value for positioning of intracranial EEG electrodes. (au) 36 refs.

  17. Salt-occluded zeolite waste forms: Crystal structures and transformability

    International Nuclear Information System (INIS)

    Richardson, J.W. Jr.

    1996-01-01

    Neutron diffraction studies of salt-occluded zeolite and zeolite/glass composite samples, simulating nuclear waste forms loaded with fission products, have revealed complex structures, with cations assuming the dual roles of charge compensation and occlusion (cluster formation). These clusters roughly fill the 6--8 angstrom diameter pores of the zeolites. Samples are prepared by equilibrating zeolite-A with complex molten Li, K, Cs, Sr, Ba, Y chloride salts, with compositions representative of anticipated waste systems. Samples prepared using zeolite 4A (which contains exclusively sodium cations) as starting material are observed to transform to sodalite, a denser aluminosilicate framework structure, while those prepared using zeolite 5A (sodium and calcium ions) more readily retain the zeolite-A structure. Because the sodalite framework pores are much smaller than those of zeolite-A, clusters are smaller and more rigorously confined, with a correspondingly lower capacity for waste containment. Details of the sodalite structures resulting from transformation of zeolite-A depend upon the precise composition of the original mixture. The enhanced resistance of salt-occluded zeolites prepared from zeolite 5A to sodalite transformation is thought to be related to differences in the complex chloride clusters present in these zeolite mixtures. Data relating processing conditions to resulting zeolite composition and structure can be used in the selection of processing parameters which lead to optimal waste forms

  18. Magnetic resonance imaging in 120 patients with intractable partial seizures: a preoperative assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lefkopoulos, A.; Haritanti, A.; Papadopoulou, E.; Karanikolas, D.; Fotiadis, N.; Dimitriadis, A.S. [AHEPA University Hospital, Department of Radiology, Thessaloniki (Greece)

    2005-05-01

    The aim of this study was to describe magnetic resonance imaging (MRI) findings in patients with medically intractable epilepsy and to compare different magnetic resonance (MR) sequences in order to establish a dedicated and shorter scan time imaging protocol of choice. One hundred and twenty patients with seizures that were refractory to medical treatment were assessed by MRI with spin-echo (SE) T1, fast spin-echo (FSE) T2, fluid-attenuated inversion recovery (FLAIR), inversion recovery (IR) and contrast-enhanced T1 SE sequences. Pathological scans were acquired in 78 patients. Hippocampal sclerosis was detected in 30 patients (25%), cerebral, tumoral, mass lesions in 12 patients (10%), vascular malformations in nine patients (7.5%), cortical infarcts in eight patients (6.7%), cerebral infections in four patients (4.2%) and developmental disorders in 15 patients (12.5%). The most common location of the lesions was the temporal lobe (60%). Coronal, thin (slice thickness 4-5 mm) images have proven to be the most useful in the assessment of the hippocampus. FLAIR and IR are particularly useful in the detection of lesions abutting cerebrospinal fluid (CSF) spaces and developmental disorders, respectively, while T1 SE sequences before and after the intravenous administration of gadolinium offer great facility in identifying space-occupying lesions and infections. MRI is the most important diagnostic tool for the assessment of epileptogenic foci, thus playing the primary role in indicating the type of treatment to be applied. (orig.)

  19. Magnetic resonance imaging in 120 patients with intractable partial seizures: a preoperative assessment

    International Nuclear Information System (INIS)

    Lefkopoulos, A.; Haritanti, A.; Papadopoulou, E.; Karanikolas, D.; Fotiadis, N.; Dimitriadis, A.S.

    2005-01-01

    The aim of this study was to describe magnetic resonance imaging (MRI) findings in patients with medically intractable epilepsy and to compare different magnetic resonance (MR) sequences in order to establish a dedicated and shorter scan time imaging protocol of choice. One hundred and twenty patients with seizures that were refractory to medical treatment were assessed by MRI with spin-echo (SE) T1, fast spin-echo (FSE) T2, fluid-attenuated inversion recovery (FLAIR), inversion recovery (IR) and contrast-enhanced T1 SE sequences. Pathological scans were acquired in 78 patients. Hippocampal sclerosis was detected in 30 patients (25%), cerebral, tumoral, mass lesions in 12 patients (10%), vascular malformations in nine patients (7.5%), cortical infarcts in eight patients (6.7%), cerebral infections in four patients (4.2%) and developmental disorders in 15 patients (12.5%). The most common location of the lesions was the temporal lobe (60%). Coronal, thin (slice thickness 4-5 mm) images have proven to be the most useful in the assessment of the hippocampus. FLAIR and IR are particularly useful in the detection of lesions abutting cerebrospinal fluid (CSF) spaces and developmental disorders, respectively, while T1 SE sequences before and after the intravenous administration of gadolinium offer great facility in identifying space-occupying lesions and infections. MRI is the most important diagnostic tool for the assessment of epileptogenic foci, thus playing the primary role in indicating the type of treatment to be applied. (orig.)

  20. Retinal image quality and visual stimuli processing by simulation of partial eye cataract

    Science.gov (United States)

    Ozolinsh, Maris; Danilenko, Olga; Zavjalova, Varvara

    2016-10-01

    Visual stimuli were demonstrated on a 4.3'' mobile phone screen inside a "Virtual Reality" adapter that allowed separation of the left and right eye visual fields. Contrast of the retina image thus can be controlled by the image on the phone screen and parallel to that at appropriate geometry by the AC voltage applied to scattering PDLC cell inside the adapter. Such optical pathway separation allows to demonstrate to both eyes spatially variant images, that after visual binocular fusion acquire their characteristic indications. As visual stimuli we used grey and different color (two opponent components to vision - red-green in L*a*b* color space) spatially periodical stimuli for left and right eyes; and with spatial content that by addition or subtraction resulted as clockwise or counter clockwise slanted Gabor gratings. We performed computer modeling with numerical addition or subtraction of signals similar to processing in brain via stimuli input decomposition in luminance and color opponency components. It revealed the dependence of the perception psychophysical equilibrium point between clockwise or counter clockwise perception of summation on one eye image contrast and color saturation, and on the strength of the retinal aftereffects. Existence of a psychophysical equilibrium point in perception of summation is only in the presence of a prior adaptation to a slanted periodical grating and at the appropriate slant orientation of adaptation grating and/or at appropriate spatial grating pattern phase according to grating nods. Actual observer perception experiments when one eye images were deteriorated by simulated cataract approved the shift of mentioned psychophysical equilibrium point on the degree of artificial cataract. We analyzed also the mobile devices stimuli emission spectra paying attention to areas sensitive to macula pigments absorption spectral maxima and blue areas where the intense irradiation can cause in abnormalities in periodic melatonin

  1. Correction for Partial Volume Effect Is a Must, Not a Luxury, to Fully Exploit the Potential of Quantitative PET Imaging in Clinical Oncology

    DEFF Research Database (Denmark)

    Alavi, Abass; Werner, Thomas J; Høilund-Carlsen, Poul Flemming

    2018-01-01

    The partial volume effect (PVE) is considered as one of the major degrading factors impacting image quality and hampering the accuracy of quantitative PET imaging in clinical oncology. This effect is the consequence of the limited spatial resolution of whole-body PET scanners, which results in bl...

  2. Neural-network-based system for recognition of partially occluded shapes and patterns

    Science.gov (United States)

    Mital, Dinesh P.; Teoh, Eam-Khwang; Amarasinghe, S. K.; Suganthan, P. N.

    1996-10-01

    The purpose of this paper is to demonstrate how a structural matching approach can be used to perfonn effective rotational invariant fingerprint identification. In this approach, each of the exiracted features is correlated with Live of its nearest neighbouring features to form a local feature gmup for a first-stage matching. After that, the feature with the highest match is used as a central feature whereby all the other features are correlated to form a global feature group for a second.stage matching. The correlation between the features is in terms of distance and relative angle. This approach actually make the matching method rotational invariant A substantial amount of testing was carried out and it shows that this matching technique is capable of matching the four basic fingerprint patterns with an average matching time of4 seconds on a 66Mhz, 486 DX personal computer.

  3. Sequential combination of k-t principle component analysis (PCA) and partial parallel imaging: k-t PCA GROWL.

    Science.gov (United States)

    Qi, Haikun; Huang, Feng; Zhou, Hongmei; Chen, Huijun

    2017-03-01

    k-t principle component analysis (k-t PCA) is a distinguished method for high spatiotemporal resolution dynamic MRI. To further improve the accuracy of k-t PCA, a combination with partial parallel imaging (PPI), k-t PCA/SENSE, has been tested. However, k-t PCA/SENSE suffers from long reconstruction time and limited improvement. This study aims to improve the combination of k-t PCA and PPI on both reconstruction speed and accuracy. A sequential combination scheme called k-t PCA GROWL (GRAPPA operator for wider readout line) was proposed. The GRAPPA operator was performed before k-t PCA to extend each readout line into a wider band, which improved the condition of the encoding matrix in the following k-t PCA reconstruction. k-t PCA GROWL was tested and compared with k-t PCA and k-t PCA/SENSE on cardiac imaging. k-t PCA GROWL consistently resulted in better image quality compared with k-t PCA/SENSE at high acceleration factors for both retrospectively and prospectively undersampled cardiac imaging, with a much lower computation cost. The improvement in image quality became greater with the increase of acceleration factor. By sequentially combining the GRAPPA operator and k-t PCA, the proposed k-t PCA GROWL method outperformed k-t PCA/SENSE in both reconstruction speed and accuracy, suggesting that k-t PCA GROWL is a better combination scheme than k-t PCA/SENSE. Magn Reson Med 77:1058-1067, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  4. Facial expression recognition under partial occlusion based on fusion of global and local features

    Science.gov (United States)

    Wang, Xiaohua; Xia, Chen; Hu, Min; Ren, Fuji

    2018-04-01

    Facial expression recognition under partial occlusion is a challenging research. This paper proposes a novel framework for facial expression recognition under occlusion by fusing the global and local features. In global aspect, first, information entropy are employed to locate the occluded region. Second, principal Component Analysis (PCA) method is adopted to reconstruct the occlusion region of image. After that, a replace strategy is applied to reconstruct image by replacing the occluded region with the corresponding region of the best matched image in training set, Pyramid Weber Local Descriptor (PWLD) feature is then extracted. At last, the outputs of SVM are fitted to the probabilities of the target class by using sigmoid function. For the local aspect, an overlapping block-based method is adopted to extract WLD features, and each block is weighted adaptively by information entropy, Chi-square distance and similar block summation methods are then applied to obtain the probabilities which emotion belongs to. Finally, fusion at the decision level is employed for the data fusion of the global and local features based on Dempster-Shafer theory of evidence. Experimental results on the Cohn-Kanade and JAFFE databases demonstrate the effectiveness and fault tolerance of this method.

  5. Morphological image processing operators. Reduction of partial volume effects to improve 3D visualization based on CT data

    International Nuclear Information System (INIS)

    Beier, J.; Bittner, R.C.; Hosten, N.; Troeger, J.; Felix, R.

    1998-01-01

    Aim: The quality of segmentation and three-dimensional reconstruction of anatomical structures in tomographic slices is often impaired by disturbances due to partial volume effects (PVE). The potential for artefact reduction by use of the morphological image processing operators (MO) erosion and dilation is investigated. Results: For all patients under review, the artefacts caused by PVE were significantly reduced by erosion (lung: Mean SBR pre =1.67, SBR post =4.83; brain: SBR pre =1.06, SBR post =1.29) even with only a small number of iterations. Region dilation was applied to integrate further structures (e.g. at tumor borders) into a configurable neighbourhood for segmentation and quantitative analysis. Conclusions: The MO represent an efficient approach for the reduction of PVE artefacts in 3D-CT reconstructions and allow optimised visualization of individual objects. (orig./AJ) [de

  6. Registration of partially overlapping surfaces for range image based augmented reality on mobile devices

    Science.gov (United States)

    Kilgus, T.; Franz, A. M.; Seitel, A.; Marz, K.; Bartha, L.; Fangerau, M.; Mersmann, S.; Groch, A.; Meinzer, H.-P.; Maier-Hein, L.

    2012-02-01

    Visualization of anatomical data for disease diagnosis, surgical planning, or orientation during interventional therapy is an integral part of modern health care. However, as anatomical information is typically shown on monitors provided by a radiological work station, the physician has to mentally transfer internal structures shown on the screen to the patient. To address this issue, we recently presented a new approach to on-patient visualization of 3D medical images, which combines the concept of augmented reality (AR) with an intuitive interaction scheme. Our method requires mounting a range imaging device, such as a Time-of-Flight (ToF) camera, to a portable display (e.g. a tablet PC). During the visualization process, the pose of the camera and thus the viewing direction of the user is continuously determined with a surface matching algorithm. By moving the device along the body of the patient, the physician is given the impression of looking directly into the human body. In this paper, we present and evaluate a new method for camera pose estimation based on an anisotropic trimmed variant of the well-known iterative closest point (ICP) algorithm. According to in-silico and in-vivo experiments performed with computed tomography (CT) and ToF data of human faces, knees and abdomens, our new method is better suited for surface registration with ToF data than the established trimmed variant of the ICP, reducing the target registration error (TRE) by more than 60%. The TRE obtained (approx. 4-5 mm) is promising for AR visualization, but clinical applications require maximization of robustness and run-time.

  7. Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention.

    Science.gov (United States)

    Kishino, Mitsuhiro; Nakaminato, Shuichiro; Kitazume, Yoshio; Miyasaka, Naoyuki; Kudo, Toshifumi; Saida, Yukihisa; Tateishi, Ukihide

    2018-07-01

    The usefulness of carbon dioxide (CO 2 ) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO 2 gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO 2 DSA (B-CO 2 DSA) as an improved CO 2 DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO 2 DSA and B-CO 2 DSA. B-CO 2 DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10-15 ml of CO 2 gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion. In all four cases, image quality was improved with B-CO 2 DSA; the poor quality of images without balloon occlusion was because of reflux of the CO 2 gas. B-CO 2 DSA improves the image quality of CO 2 DSA in the IIA region and is useful for vascular intervention. Level IV.

  8. {sup 99m}Tc-glucarate imaging for the early detection of infarct in partially reperfused canine myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Gerald; Okada, Christine C.; Hocherman, Sonia D. [University of Oklahoma Health Sciences Center, Tulsa, OK (United States); Liu, Zhonglin [University of Arizona, Tucson, AZ (United States); Hart, Curtis [University of Texas, San Antonio, TX (United States); Khaw, Ban-An [Northeastern University, Boston, MA (United States); Okada, Robert D. [University of Oklahoma Health Sciences Center, Tulsa, OK (United States); University of Tulsa, Department of Biology, Tulsa, OK (United States)

    2006-03-15

    {sup 99m}Tc-glucarate is an imaging agent developed for the detection of acutely infarcted myocardium. The purposes of the current study were to (1) determine whether {sup 99m}Tc-glucarate can detect acute infarct in the setting of only partial minimal reperfusion, (2) study the persistence and time course of scan positivity following coronary occlusion and intravenous tracer injection, (3) assess the ability of {sup 99m}Tc-glucarate to determine infarct size, and (4) compare these data with previous results obtained using a 100% reperfusion model. Six dogs underwent left circumflex (LCx) coronary occlusion for 90 min, followed by 10% epicardial blood flow reperfusion. Fifteen mCi (555 MBq) {sup 99m}Tc-glucarate was injected intravenously 30 min later. Serial gamma camera images were acquired over 240 min. Microsphere blood flow determinations were performed at baseline, during occlusion, during tracer administration, and just before euthanasia. Ex vivo gamma camera images were obtained. Triphenyltetrazolium chloride (TTC) staining was performed to assess infarct size. Qualitatively, {sup 99m}Tc-glucarate images showed a well-defined ''hot spot'' in all six dogs by 30 min after tracer injection (150 min following coronary occlusion), which persisted for 240 min following tracer administration. Quantitatively, there was a significant increase in the LCx/LAD (left anterior descending) counts ratio beginning 10 min after tracer administration (130 min after occlusion), and continuing to 240 min after tracer administration. Tracer retention was 12.0{+-}0.9% for the LAD and 39.0{+-}4.1% for the LCx hot spot zone (p<0.05) at 240 min after {sup 99m}Tc-glucarate injection. The correlation coefficient was 0.90 for infarct size by TTC versus {sup 99m}Tc-glucarate. (orig.)

  9. 99mTc-glucarate imaging for the early detection of infarct in partially reperfused canine myocardium

    International Nuclear Information System (INIS)

    Johnson, Gerald; Okada, Christine C.; Hocherman, Sonia D.; Liu, Zhonglin; Hart, Curtis; Khaw, Ban-An; Okada, Robert D.

    2006-01-01

    99m Tc-glucarate is an imaging agent developed for the detection of acutely infarcted myocardium. The purposes of the current study were to (1) determine whether 99m Tc-glucarate can detect acute infarct in the setting of only partial minimal reperfusion, (2) study the persistence and time course of scan positivity following coronary occlusion and intravenous tracer injection, (3) assess the ability of 99m Tc-glucarate to determine infarct size, and (4) compare these data with previous results obtained using a 100% reperfusion model. Six dogs underwent left circumflex (LCx) coronary occlusion for 90 min, followed by 10% epicardial blood flow reperfusion. Fifteen mCi (555 MBq) 99m Tc-glucarate was injected intravenously 30 min later. Serial gamma camera images were acquired over 240 min. Microsphere blood flow determinations were performed at baseline, during occlusion, during tracer administration, and just before euthanasia. Ex vivo gamma camera images were obtained. Triphenyltetrazolium chloride (TTC) staining was performed to assess infarct size. Qualitatively, 99m Tc-glucarate images showed a well-defined ''hot spot'' in all six dogs by 30 min after tracer injection (150 min following coronary occlusion), which persisted for 240 min following tracer administration. Quantitatively, there was a significant increase in the LCx/LAD (left anterior descending) counts ratio beginning 10 min after tracer administration (130 min after occlusion), and continuing to 240 min after tracer administration. Tracer retention was 12.0±0.9% for the LAD and 39.0±4.1% for the LCx hot spot zone (p 99m Tc-glucarate injection. The correlation coefficient was 0.90 for infarct size by TTC versus 99m Tc-glucarate. (orig.)

  10. Experimental nickel elicitation thresholds--a review focusing on occluded nickel exposure

    DEFF Research Database (Denmark)

    Fischer, Louise Arup; Menné, Torkil; Johansen, Jeanne Duus

    2005-01-01

    Nickel (Ni) is the most frequent cause of contact allergy among the female population. This makes it interesting to examine thresholds for elicitation under different conditions. Even though Ni exposure may be open, occluded, penetrating or oral, most dose-response studies in the literature concern...... single occluded application. The aims of this study were to assess thresholds of response by making a statistical analysis of available dose-response studies with single occluded exposure and comparing the results to thresholds from other modes of exposure. 8 occluded Ni dose-response studies were...... 10% reacted in occluded exposure. When combining the exposure to Ni with an irritant, divagating results were found, although the literature shows evidence of an augmented response when combining exposure to an allergen and an irritant. The thresholds of penetrating exposure were found to be lower...

  11. Need for intraoperative ultrasound and surgical recommendation for partial nephrectomy: correlation with tumor imaging features and urologist practice patterns.

    Science.gov (United States)

    Sun, Maryellen R M; Wagner, Andrew A; San Francisco, Ignacio F; Brook, Alexander; Kavoussi, Louis; Russo, Paul; Steele, Graeme; Viterbo, Rosalia; Pedrosa, Ivan

    2012-03-01

    This study aimed to evaluate the need for intraoperative ultrasound (IOUS) and recommendation for surgical approach in the resection of renal tumors through a survey of practicing urologists, with correlation to tumor imaging features and urologist practice pattern. An institutional review board-approved retrospective review, compliant with the Health Insurance Portability and Accountability Act, of 44 renal tumors that underwent laparoscopic partial nephrectomy at the study institution was performed. The numeric component of the RENAL nephrometry score (radius [diameter], % exophytic, nearness [to collecting system/renal sinus], location) was calculated for each case using preoperative computed tomography/magnetic resonance imaging. Five anonymized images of each tumor were presented to 4 academic urologists with varying practice patterns. Reviewers independently scored each case for its need for IOUS, for recommendation of a surgical technique, and for the difficulty of the proposed surgery. The RENAL scores were as follows: RENAL 1 (low complexity, score 4-6; n = 19); RENAL 2 (moderate complexity, score 7-9; n = 23); RENAL 3 (high complexity, score 10-12; n = 2). The only RENAL score component significantly influencing need for IOUS was percentage exophytic (P = 0.00002). There was an inverse relationship between normalized and averaged need for IOUS and percentage exophytic (P recommendation of surgical method was the reviewer him/herself, with each reviewer's recommendations closely matching his/her practice pattern. Size and percentage exophytic represented the only tumor features significantly (P = 0.03) influencing surgical recommendation. There was a significant difference in the perceived need for IOUS and surgical recommendation when 4 academic urologists reviewed a series of renal masses requiring resection. Percentage exophytic correlated inversely with need for IOUS. Urologist's practice pattern and tumor size and percentage exophytic were most

  12. Potential Impact of Preoperative Magnetic Resonance Imaging of the Breast on Patient Selection for Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Kühr, Marietta; Wolfgarten, Matthias; Stölzle, Marco; Leutner, Claudia; Höller, Tobias; Schrading, Simone; Kuhl, Christiane; Schild, Hans; Kuhn, Walther; Braun, Michael

    2011-01-01

    Purpose: Accelerated partial breast irradiation (APBI) after breast-conserving therapy is currently under investigation in prospective randomized studies. Multifocality and multicentricity are exclusion criteria for APBI. Preoperative breast magnetic resonance imaging (MRI) can detect ipsilateral and contralateral invasive tumor foci or ductal carcinoma in situ in addition to conventional diagnostic methods (clinical examination, mammography, and ultrasonography). The objective of this retrospective study was to evaluate the impact of preoperative MRI on patient selection for APBI. Methods and Materials: From 2002 to 2007, a total of 579 consecutive, nonselected patients with newly diagnosed early-stage breast cancer received preoperative breast MRI in addition to conventional imaging studies at the Bonn University Breast Cancer Center. In retrospect, 113 patients would have met the criteria for APBI using conventional imaging workup (clinical tumor size ≤3 cm; negative axillary lymph node status; unifocal disease; no evidence of distant metastases; no invasive lobular carcinoma, ductal and lobular carcinoma in situ, or Paget’s disease). We analyzed the amount of additional ipsilateral and contralateral tumor foci detected by MRI. Results: MRI detected additional tumor foci in 8.8% of patients eligible for APBI (11 tumor foci in 10 of 113 patients), either ipsilateral (n = 7, 6.2%) or contralateral (n = 4, 3.5%). In 1 patient, MRI helped detect additional tumor focus both ipsilaterally and contralaterally. Conclusions: Preoperative breast MRI is able to identify additional tumor foci in a clinically relevant number of cases in this highly selected group of patients with low-risk disease and may be useful in selecting patients for APBI.

  13. Potential Impact of Preoperative Magnetic Resonance Imaging of the Breast on Patient Selection for Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kuehr, Marietta, E-mail: marietta.kuehr@ukb.uni-bonn.de [Department of Obstetrics and Gynecology and Center of Integrated Oncology, University of Bonn, Bonn (Germany); Wolfgarten, Matthias; Stoelzle, Marco [Department of Obstetrics and Gynecology and Center of Integrated Oncology, University of Bonn, Bonn (Germany); Leutner, Claudia [Department of Radiology, Center of Integrated Oncology, University of Bonn, Bonn (Germany); Hoeller, Tobias [Department of Medical Statistics and Epidemiology, University of Bonn, Bonn (Germany); Schrading, Simone; Kuhl, Christiane; Schild, Hans [Department of Radiology, Center of Integrated Oncology, University of Bonn, Bonn (Germany); Kuhn, Walther; Braun, Michael [Department of Obstetrics and Gynecology and Center of Integrated Oncology, University of Bonn, Bonn (Germany)

    2011-11-15

    Purpose: Accelerated partial breast irradiation (APBI) after breast-conserving therapy is currently under investigation in prospective randomized studies. Multifocality and multicentricity are exclusion criteria for APBI. Preoperative breast magnetic resonance imaging (MRI) can detect ipsilateral and contralateral invasive tumor foci or ductal carcinoma in situ in addition to conventional diagnostic methods (clinical examination, mammography, and ultrasonography). The objective of this retrospective study was to evaluate the impact of preoperative MRI on patient selection for APBI. Methods and Materials: From 2002 to 2007, a total of 579 consecutive, nonselected patients with newly diagnosed early-stage breast cancer received preoperative breast MRI in addition to conventional imaging studies at the Bonn University Breast Cancer Center. In retrospect, 113 patients would have met the criteria for APBI using conventional imaging workup (clinical tumor size {<=}3 cm; negative axillary lymph node status; unifocal disease; no evidence of distant metastases; no invasive lobular carcinoma, ductal and lobular carcinoma in situ, or Paget's disease). We analyzed the amount of additional ipsilateral and contralateral tumor foci detected by MRI. Results: MRI detected additional tumor foci in 8.8% of patients eligible for APBI (11 tumor foci in 10 of 113 patients), either ipsilateral (n = 7, 6.2%) or contralateral (n = 4, 3.5%). In 1 patient, MRI helped detect additional tumor focus both ipsilaterally and contralaterally. Conclusions: Preoperative breast MRI is able to identify additional tumor foci in a clinically relevant number of cases in this highly selected group of patients with low-risk disease and may be useful in selecting patients for APBI.

  14. Comparison of Laser Doppler Imaging (LDI) and clinical assessment in differentiating between superficial and deep partial thickness burn wounds.

    Science.gov (United States)

    Jan, Saadia Nosheen; Khan, Farid Ahmed; Bashir, Muhammad Mustehsan; Nasir, Muneeb; Ansari, Hamid Hussain; Shami, Hussan Birkhez; Nazir, Umer; Hanif, Asif; Sohail, Muhammad

    2018-03-01

    To compare the accuracy of Laser Doppler Imaging (LDI) and clinical assessment in differentiating between superficial and deep partial thickness burns to decide whether early tangential excision and grafting or conservative management should be employed to optimize burn and patient management. March 2015 to November 2016. Ninety two wounds in 34 patients reporting within 5days of less than 40% burn surface area were included. Unstable patients, pregnant females and those who expired were excluded. The wounds were clinically assessed and LDI done concomitantly Plastic Surgeons blinded to each other's findings. Wound appearance, color, blanching, pain, hair follicle dislodgement were the clinical parameters that distinguished between superficial and deep partial thickness burns. On day 21, the wounds were again assessed for the presence of healing by the same plastic surgeons. The findings were correlated with the initial findings on LDI and clinical assessment and the results statistically analyzed. The data of 92 burn wounds was analyzed using SPSS (ver. 17). Clinical assessment correctly identified the depth of 75 and LDI 83 wounds, giving diagnostic accuracies of 81.52% and 90.21% respectively. The sensitivity of clinical assessment was 81% and of LDI 92.75%, whereas the specificity was 82% for both. The positive predictive value was 93% for clinical assessment and 94% for LDI while the negative predictive value was 59% and 79% respectively. Predictive accuracy of LDI was found to be better than clinical assessment in the prediction of wound healing, the gold standard for wound healing being 21 days. As such it can prove to be a reliable and viable cost effective alternative per se to clinical assessment. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  15. A Prospective Study of the Utility of Magnetic Resonance Imaging in Determining Candidacy for Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dorn, Paige L.; Al-Hallaq, Hania A.; Haq, Farah; Goldberg, Mira [Department of Radiation and Cellular Oncology, University of Chicago Medical Center, Chicago, Illinois (United States); Abe, Hiroyuki [Department of Radiology, University of Chicago Medical Center, Chicago, Illinois (United States); Hasan, Yasmin [Department of Radiation and Cellular Oncology, University of Chicago Medical Center, Chicago, Illinois (United States); Chmura, Steven J., E-mail: schmura@radonc.uchicago.edu [Department of Radiation and Cellular Oncology, University of Chicago Medical Center, Chicago, Illinois (United States)

    2013-03-01

    Purpose: Retrospective data have demonstrated that breast magnetic resonance imaging (MRI) may change a patient's eligibility for partial breast irradiation (PBI) by identifying multicentric, multifocal, or contralateral disease. The objective of the current study was to prospectively determine the frequency with which MRI identifies occult disease and to establish clinical factors associated with a higher likelihood of MRI prompting changes in PBI eligibility. Methods and Materials: At The University of Chicago, women with breast cancer uniformly undergo MRI in addition to mammography and ultrasonography. From June 2009 through May 2011, all patients were screened prospectively in a multidisciplinary conference for PBI eligibility based on standard imaging, and the impact of MRI on PBI eligibility according to National Surgical Adjuvant Breast and Bowel Project protocol B-39/Radiation Therapy Oncology Group protocol 0413 entry criteria was recorded. Univariable analysis was performed using clinical characteristics in both the prospective cohort and in a separate cohort of retrospectively identified patients. Pooled analysis was used to derive a scoring index predictive of the risk that MRI would identify additional disease. Results: A total of 521 patients were screened for PBI eligibility, and 124 (23.8%) patients were deemed eligible for PBI based on standard imaging. MRI findings changed PBI eligibility in 12.9% of patients. In the pooled univariable analysis, tumor size ≥2 cm on mammography or ultrasonography (P=.02), age <50 years (P=.01), invasive lobular histology (P=.01), and HER-2/neu amplification (P=.01) were associated with a higher likelihood of MRI changing PBI eligibility. A predictive score was generated by summing the number of significant risk factors. Patients with a score of 0, 1, 2, and 3 had changes to eligibility based on MRI findings in 2.8%, 13.2%, 38.1%, and 100%, respectively (P<.0001). Conclusions: MRI identified additional

  16. Comparison of factors associated with occludable angle between american Caucasians and ethnic Chinese.

    Science.gov (United States)

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-11-21

    To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40-80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese.

  17. Classification System for Identifying Women at Risk for Altered Partial Breast Irradiation Recommendations After Breast Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Kowalchik, Kristin V.; Vallow, Laura A.; McDonough, Michelle; Thomas, Colleen S.; Heckman, Michael G.; Peterson, Jennifer L.; Adkisson, Cameron D.; Serago, Christopher; McLaughlin, Sarah A.

    2013-01-01

    Purpose: To study the utility of preoperative breast MRI for partial breast irradiation (PBI) patient selection, using multivariable analysis of significant risk factors to create a classification rule. Methods and Materials: Between 2002 and 2009, 712 women with newly diagnosed breast cancer underwent preoperative bilateral breast MRI at Mayo Clinic Florida. Of this cohort, 566 were retrospectively deemed eligible for PBI according to the National Surgical Adjuvant Breast and Bowel Project Protocol B-39 inclusion criteria using physical examination, mammogram, and/or ultrasound. Magnetic resonance images were then reviewed to determine their impact on patient eligibility. The patient and tumor characteristics were evaluated to determine risk factors for altered PBI eligibility after MRI and to create a classification rule. Results: Of the 566 patients initially eligible for PBI, 141 (25%) were found ineligible because of pathologically proven MRI findings. Magnetic resonance imaging detected additional ipsilateral breast cancer in 118 (21%). Of these, 62 (11%) had more extensive disease than originally noted before MRI, and 64 (11%) had multicentric disease. Contralateral breast cancer was detected in 28 (5%). Four characteristics were found to be significantly associated with PBI ineligibility after MRI on multivariable analysis: premenopausal status (P=.021), detection by palpation (P<.001), first-degree relative with a history of breast cancer (P=.033), and lobular histology (P=.002). Risk factors were assigned a score of 0-2. The risk of altered PBI eligibility from MRI based on number of risk factors was 0:18%; 1:22%; 2:42%; 3:65%. Conclusions: Preoperative bilateral breast MRI altered the PBI recommendations for 25% of women. Women who may undergo PBI should be considered for breast MRI, especially those with lobular histology or with 2 or more of the following risk factors: premenopausal, detection by palpation, and first-degree relative with a history of

  18. Investigation of variability in image acquisition and contouring during 3D ultrasound guidance for partial breast irradiation

    International Nuclear Information System (INIS)

    Landry, Anthony; Olivotto, Ivo; Beckham, Wayne; Berrang, Tanya; Gagne, Isabelle; Popescu, Carmen; Mitchell, Tracy; Vey, Hazel; Sand, Letricia; Soh, Siew Yan; Wark, Jill

    2014-01-01

    Three-dimensional ultrasound (3DUS) at simulation compared to 3DUS at treatment is an image guidance option for partial breast irradiation (PBI). This study assessed if user dependence in acquiring and contouring 3DUS (operator variability) contributed to variation in seroma shifts calculated for breast IGRT. Eligible patients met breast criteria for current randomized PBI studies. 5 Operators participated in this study. For each patient, 3 operators were involved in scan acquisitions and 5 were involved in contouring. At CT simulation (CT1), a 3DUS (US1) was performed by a single radiation therapist (RT). 7 to 14 days after CT1 a second CT (CT2) and 3 sequential 3DUS scans (US2a,b,c) were acquired by each of 3 RTs. Seroma shifts, between US1 and US2 scans were calculated by comparing geometric centers of the seromas (centroids). Operator contouring variability was determined by comparing 5 RT’s contours for a single image set. Scanning variability was assessed by comparing shifts between multiple scans acquired at the same time point (US1-US2a,b,c). Shifts in seromas contoured on CT (CT1-CT2) were compared to US data. From an initial 28 patients, 15 had CT visible seromas, met PBI dosimetric constraints, had complete US data, and were analyzed. Operator variability contributed more to the overall variability in seroma localization than the variability associated with multiple scan acquisitions (95% confidence mean uncertainty of 6.2 mm vs. 1.1 mm). The mean standard deviation in seroma shift was user dependent and ranged from 1.7 to 2.9 mm. Mean seroma shifts from simulation to treatment were comparable to CT. Variability in shifts due to different users acquiring and contouring 3DUS for PBI guidance were comparable to CT shifts. Substantial inter-observer effect needs to be considered during clinical implementation of 3DUS IGRT

  19. High resolution magnetic resonance imaging in adults with partial or secondary generalised epilepsy attending a tertiary referral unit.

    Science.gov (United States)

    Li, L M; Fish, D R; Sisodiya, S M; Shorvon, S D; Alsanjari, N; Stevens, J M

    1995-10-01

    In the past the underlying structural abnormalities leading to the development of chronic seizure disorders have usually only been disclosed by histological examination of surgical or postmortem material, due to their often subtle nature that was beyond the resolution of CT or early MRI. The MRI findings in 341 patients with chronic, refractory epilepsy attending The National Hospital for Neurology and Neurosurgery and Chalfont Centre for Epilepsy are reported. Studies were performed on a 1.5 Tesla scanner with a specific volumetric protocol, allowing the reconstruction of 1.5 mm contiguous slices throughout the whole brain. Direct visual inspection of the two dimensional images without the use of additional quantitative measures showed that 254/341 (74%) were abnormal. Twenty four (7%) patients had more than one lesion. The principal MRI diagnoses were hippocampal asymmetry (32%), cortical dysgenesis (12%), tumour (12%), and vascular malformation (8%). Pathological confirmation was available from surgical specimens in 70 patients and showed a very high degree of sensitivity and specificity for the different entities. The advent of more widely available high resolution MRI should make it possible to identify the underlying pathological substrate in most patients with chronic partial epilepsy. This will allow a fundamental reclassification of the epilepsies for both medical and surgical management, with increasing precision as new methods (both of acquisition and postprocessing) are added to the neuroimaging battery used in clinical practice.

  20. Aspirex Thrombectomy in Occluded Dialysis Access: A Retrospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Dyer, Jules, E-mail: Jules.Dyer@nhs.net [New Cross Hospital, Department of Radiology (United Kingdom); Rosa, Joao [University Hospitals Bristol NHS Foundation Trust, ST1 Radiology (United Kingdom); Chachlani, Menka [University of Birmingham (United Kingdom); Nicholas, Johann [New Cross Hospital, Department of Radiology (United Kingdom)

    2016-10-15

    PurposeThis study is the first to present the outcomes of the Straub Aspirex device for the salvage of occluded renal dialysis access fistulae.Materials and MethodsThis is a retrospective study, using data from the Renal Unit and Radiology Department database. It included all the patients between 2010 and 2014 who underwent percutaneous mechanical thrombectomy (PMT) treated by JD. Aspirex is an over-the-wire, 6–10 French catheter within which is a rapidly rotating helix which draws thrombus into a window near the tip which it then macerates and removes. Access survival was assessed using the Kaplan–Meier method, and multi-variant analysis was performed using the Cox proportional hazards model. Significance was considered if p < 0.05.ResultsA total of 27 procedures were performed for 19 patients. 13 had autologous arterio-venous fistulae, and 14 had synthetic (PTFE) arterio-venous grafts. 15 were males, 4 females. 100 % of the patients successfully had a channel of thrombus removed. This resulted in an 81.5 % initial clinical success, with primary patency rates of 53.6, 44.3 and 33 % by days 30, 90 and 480, respectively, without significant difference of any analysed covariates. No major complication (pulmonary embolus, paradoxical cerebral infarction, limb ischaemia or significant haemorrhage) occurred.ConclusionAspirex has rates of patency and complication similar to other PMT devices. No covariant studied affected outcome.

  1. Optical image-hiding method with false information disclosure based on the interference principle and partial-phase-truncation in the fractional Fourier domain

    International Nuclear Information System (INIS)

    Dai, Chaoqing; Wang, Xiaogang; Zhou, Guoquan; Chen, Junlang

    2014-01-01

    An image-hiding method based on the optical interference principle and partial-phase-truncation in the fractional Fourier domain is proposed. The primary image is converted into three phase-only masks (POMs) using an analytical algorithm involved partial-phase-truncation and a fast random pixel exchange process. A procedure of a fake silhouette for a decryption key is suggested to reinforce the encryption and give a hint of the position of the key. The fractional orders of FrFT effectively enhance the security of the system. In the decryption process, the POM with false information and the other two POMs are, respectively, placed in the input and fractional Fourier planes to recover the primary image. There are no unintended information disclosures and iterative computations involved in the proposed method. Simulation results are presented to verify the validity of the proposed approach. (letters)

  2. Effects of Injection Timing on Fluid Flow Characteristics of Partially Premixed Combustion Based on High-Speed Particle Image Velocimetry

    KAUST Repository

    Izadi Najafabadi, Mohammad

    2017-03-28

    Partially Premixed Combustion (PPC) is a promising combustion concept ,based on judicious tuning of the charge stratification, to meet the increasing demands of emission legislation and to improve fuel efficiency. Longer ignition delays of PPC in comparison with conventional diesel combustion provide better fuel/air mixture which decreases soot and NO emissions. Moreover, a proper injection timing and strategy for PPC can improve the combustion stability as a result of a higher level of fuel stratification in comparison with the Homogeneous Charge Compression Ignition (HCCI) concept. Injection timing is the major parameter with which to affect the level of fuel and combustion stratification and to control the combustion phasing and the heat release behavior. The scope of the present study is to investigate the fluid flow characteristics of PPC at different injection timings. To this end, high-speed Particle Image Velocimetry (PIV) is implemented in a light-duty optical engine to measure fluid flow characteristics, including the flow fields, mean velocity and cycle-resolved turbulence, inside the piston bowl as well as the squish region with a temporal resolution of 1 crank angle degree at 800 rpm. Two injectors, having 5 and 7 holes, were compared to see their effects on fluid flow and heat release behavior for different injection timings. Reactive and non-reactive measurements were performed to distinguish injection-driven and combustion-driven turbulence. Formation of vortices and higher turbulence levels enhance the air/fuel interaction, changing the level of fuel stratification and combustion duration. Results demonstrate clearly how turbulence level correlates with heat release behavior, and provide a quantitative dataset for validation of numerical simulations.

  3. Face Attention Network: An Effective Face Detector for the Occluded Faces

    OpenAIRE

    Wang, Jianfeng; Yuan, Ye; Yu, Gang

    2017-01-01

    The performance of face detection has been largely improved with the development of convolutional neural network. However, the occlusion issue due to mask and sunglasses, is still a challenging problem. The improvement on the recall of these occluded cases usually brings the risk of high false positives. In this paper, we present a novel face detector called Face Attention Network (FAN), which can significantly improve the recall of the face detection problem in the occluded case without comp...

  4. Successful Balloon-Occluded Retrograde Transvenous Obliteration for Gastric Varix Mainly Draining into the Pericardiophrenic Vein

    International Nuclear Information System (INIS)

    Kageyama, Ken; Nishida, N.; Matsui, H.; Yamamoto, A.; Nakamura, K.; Miki, Y.

    2012-01-01

    Two cases of gastric varices were treated by balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein at our hospital, and both were successful. One case developed left hydrothorax. Gastric varices did not bled and esophageal varices were not aggravated in both cases for 24–30 months thereafter. These outcomes indicate the feasibility of balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein.

  5. Recanalisation of Chronically Occluded Remote Superficial Femoral Artery Endarterectomy Through Angioplasty for Limb Salvage

    Energy Technology Data Exchange (ETDEWEB)

    Husainy, Mohammad Ali, E-mail: m.husainy@nhs.net [King’s College Hospital, Department of Radiology (United Kingdom); Slim, Hani; Rashid, Hisham [King’s College Hospital, Department of Vascular Surgery (United Kingdom); Huang, Dean Y. [King’s College Hospital, Department of Radiology (United Kingdom)

    2017-02-15

    We report a novel application of balloon angioplasty to recanalise a chronically occluded remote endarterectomy superficial femoral artery. This patient previously had two occluded surgical bypass grafts in an attempt to revascularise the limb and presented with critical limb ischaemia and necrotic foot ulcerations. Following the angioplasty, the patient showed significant improvement in rest pain and healing of the ulcerations. This technique may be useful for limb salvage in patients where surgical options have been exhausted.

  6. Transcatheter Closure of Bilateral Multiple Huge Pulmonary Arteriovenous Malformations with Homemade Double-Umbrella Occluders

    International Nuclear Information System (INIS)

    Zhong Hongshan; Xu Ke; Shao Haibo

    2008-01-01

    A 28-year-old man underwent successful transcatheter occlusion of three huge pulmonary arteriovenous malformations (PAVMs) using homemade double-umbrella occluders and stainless steel coils. Thoracic CT with three-dimensional reconstruction and pulmonary angiography were used for treatment planning and follow-up. The diameters of the feeding vessels were 11 mm, 13 mm, and 14 mm, respectively. This report demonstrates the novel design and utility of the double-umbrella occluder, an alternative tool for treatment of large PAVMs.

  7. Identification and characterization of steady and occluded water in drinking water distribution systems.

    Science.gov (United States)

    Tong, Huiyan; Zhao, Peng; Zhang, Hongwei; Tian, Yimei; Chen, Xi; Zhao, Weigao; Li, Mei

    2015-01-01

    Deterioration and leakage of drinking water in distribution systems have been a major issue in the water industry for years, which are associated with corrosion. This paper discovers that occluded water in the scales of the pipes has an acidic environment and high concentration of iron, manganese, chloride, sulfate and nitrate, which aggravates many pipeline leakage accidents. Six types of water samples have been analyzed under the flowing and stagnant periods. Both the water in the exterior of the tubercles and stagnant water carry suspended iron particles, which explains the occurrence of "red water" when the system hydraulic conditions change. Nitrate is more concentrated in occluded water under flowing condition in comparison with that in flowing water. However, the concentration of nitrate in occluded water under stagnant condition is found to be less than that in stagnant water. A high concentration of manganese is found to exist in steady water, occluded water and stagnant water. These findings impact secondary pollution and the corrosion of pipes and containers used in drinking water distribution systems. The unique method that taking occluded water from tiny holes which were drilled from the pipes' exteriors carefully according to the positions of corrosion scales has an important contribution to research on corrosion in distribution systems. And this paper furthers our understanding and contributes to the growing body of knowledge regarding occluded environments in corrosion scales. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Safety, dose, and timing of reteplase in treating occluded central venous catheters in children with cancer.

    Science.gov (United States)

    Terrill, Kelly R; Lemons, Richard S; Goldsby, Robert E

    2003-11-01

    Recombinant tissue plasminogen activator, alteplase, began to be commonly used to restore the patency of occluded central venous catheters (CVCs) as urokinase production was halted in the late 1990s. However, alteplase often requires an extended dwell time to restore patency to occluded CVCs. In adults, reteplase, a newer thrombolytic agent, has been reported to restore patency to CVCs in 30 minutes. The authors prospectively evaluated the safety and efficacy of reteplase in restoring patency to occluded CVCs in children with cancer. This was a dose escalation trial. The dose of reteplase was initiated at 0.1 units and increased by increments of 0.1 units to a maximum dose of 0.4 units. Each dose was tested on at least three participants. Time to patency after reteplase administration was recorded by nurses caring for the patients. Attempts to access the line occurred every 15 minutes for 1 hour. CVCs that remained occluded after 1 hour were treated with alteplase. Reteplase was administered to 15 clotted CVCs. Twelve of the 15 were cleared with an average dwell time of 38 minutes. The time to patency did not appear to correlate with the dose. No adverse events were reported. Reteplase can restore patency to occluded CVCs in a pediatric population. Reteplase appears to have comparable efficacy with alteplase, but reteplase may require shorter dwell times. A prospective, randomized, clinical trial is warranted to determine whether reteplase is as effective as alteplase in restoring patency to occluded CVCs.

  9. Preoperative balloon occluded arterial infusion chemotherapy for locally invasive bladder cancer. Accurate staging for bladder preservation

    International Nuclear Information System (INIS)

    Hayashi, Norio; Arima, Kiminobu; Kawamura, Juichi; Tochigi, Hiromi

    1999-01-01

    The possibility of bladder preservation by preoperative balloon occluded arterial infusion (BOAI) chemotherapy was studied in 111 patients with locally invasive bladder cancer. BOAI was performed by blocking the blood flow of the internal iliac artery and by performing intra-arterial infusion of adriamycin (50 mg/body) and cisplatin (100 mg/body). Before BOAI the clinical diagnosis was T2 in 36, T3a in 29, T3b in 27, T4 in 11 and after BOAI it was T0 in 1, T1 in 27, T2 in 25, T3a in 20, T3b in 20, and T4 in 10. Down staging was observed on diagnostic images in 46.6%. Thirty patients (27.0%) received transurethral resection of bladder tumor (TUR-Bt) and their bladder could be preserved. The 5-year cancer-specific survival rate was 100% in pT0 (n=9), 97.5% in pT1 (n=47), 79.9% in pT2 (n=21), 80.0% in pT3a (n=6), 39.9% in pT3b (n=18) and 51.9% in pT4 cases (n=9). For the bladder preservation, accurate staging diagnosis is required. Since 1992, endorectal magnetic resonance imaging (MRI) has been used in addition to imaging diagnosis for improving the accuracy of staging diagnosis. The accuracies of staging diagnosis with and without endorectal MRI were 62.5% and 44.0%, respectively. BOAI as a neoadjuvant chemotherapy has the possibility of bladder-preserving therapy in locally invasive bladder cancer. Also, the endorectal MRI can improve the accuracy of staging diagnosis, which is important for the bladder preservation. (author)

  10. Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation

    Directory of Open Access Journals (Sweden)

    Guo Xiao-Mao

    2010-10-01

    Full Text Available Abstract Background The cone beam CT (CBCT guided radiation can reduce the systematic and random setup errors as compared to the skin-mark setup. However, the residual and intrafractional (RAIF errors are still unknown. The purpose of this paper is to investigate the magnitude of RAIF errors and correction action levels needed in cone beam computed tomography (CBCT guided accelerated partial breast irradiation (APBI. Methods Ten patients were enrolled in the prospective study of CBCT guided APBI. The postoperative tumor bed was irradiated with 38.5 Gy in 10 fractions over 5 days. Two cone-beam CT data sets were obtained with one before and one after the treatment delivery. The CBCT images were registered online to the planning CT images using the automatic algorithm followed by a fine manual adjustment. An action level of 3 mm, meaning that corrections were performed for translations exceeding 3 mm, was implemented in clinical treatments. Based on the acquired data, different correction action levels were simulated, and random RAIF errors, systematic RAIF errors and related margins before and after the treatments were determined for varying correction action levels. Results A total of 75 pairs of CBCT data sets were analyzed. The systematic and random setup errors based on skin-mark setup prior to treatment delivery were 2.1 mm and 1.8 mm in the lateral (LR, 3.1 mm and 2.3 mm in the superior-inferior (SI, and 2.3 mm and 2.0 mm in the anterior-posterior (AP directions. With the 3 mm correction action level, the systematic and random RAIF errors were 2.5 mm and 2.3 mm in the LR direction, 2.3 mm and 2.3 mm in the SI direction, and 2.3 mm and 2.2 mm in the AP direction after treatments delivery. Accordingly, the margins for correction action levels of 3 mm, 4 mm, 5 mm, 6 mm and no correction were 7.9 mm, 8.0 mm, 8.0 mm, 7.9 mm and 8.0 mm in the LR direction; 6.4 mm, 7.1 mm, 7.9 mm, 9.2 mm and 10.5 mm in the SI direction; 7.6 mm, 7.9 mm, 9.4 mm, 10

  11. Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Cai, Gang; Hu, Wei-Gang; Chen, Jia-Yi; Yu, Xiao-Li; Pan, Zi-Qiang; Yang, Zhao-Zhi; Guo, Xiao-Mao; Shao, Zhi-Min; Jiang, Guo-Liang

    2010-01-01

    The cone beam CT (CBCT) guided radiation can reduce the systematic and random setup errors as compared to the skin-mark setup. However, the residual and intrafractional (RAIF) errors are still unknown. The purpose of this paper is to investigate the magnitude of RAIF errors and correction action levels needed in cone beam computed tomography (CBCT) guided accelerated partial breast irradiation (APBI). Ten patients were enrolled in the prospective study of CBCT guided APBI. The postoperative tumor bed was irradiated with 38.5 Gy in 10 fractions over 5 days. Two cone-beam CT data sets were obtained with one before and one after the treatment delivery. The CBCT images were registered online to the planning CT images using the automatic algorithm followed by a fine manual adjustment. An action level of 3 mm, meaning that corrections were performed for translations exceeding 3 mm, was implemented in clinical treatments. Based on the acquired data, different correction action levels were simulated, and random RAIF errors, systematic RAIF errors and related margins before and after the treatments were determined for varying correction action levels. A total of 75 pairs of CBCT data sets were analyzed. The systematic and random setup errors based on skin-mark setup prior to treatment delivery were 2.1 mm and 1.8 mm in the lateral (LR), 3.1 mm and 2.3 mm in the superior-inferior (SI), and 2.3 mm and 2.0 mm in the anterior-posterior (AP) directions. With the 3 mm correction action level, the systematic and random RAIF errors were 2.5 mm and 2.3 mm in the LR direction, 2.3 mm and 2.3 mm in the SI direction, and 2.3 mm and 2.2 mm in the AP direction after treatments delivery. Accordingly, the margins for correction action levels of 3 mm, 4 mm, 5 mm, 6 mm and no correction were 7.9 mm, 8.0 mm, 8.0 mm, 7.9 mm and 8.0 mm in the LR direction; 6.4 mm, 7.1 mm, 7.9 mm, 9.2 mm and 10.5 mm in the SI direction; 7.6 mm, 7.9 mm, 9.4 mm, 10.1 mm and 12.7 mm in the AP direction

  12. Use of partial least squares discriminant analysis on visible-near infrared multispectral image data to examine germination ability and germ length in spinach seeds

    DEFF Research Database (Denmark)

    Shetty, Nisha; Olesen, Merete Halkjær; Gislum, René

    2012-01-01

    Because of the difficulties in obtaining homogenous germination of spinach seeds for baby leaf production, the possibility of using partial least squares discriminant analysis (PLS-DA) on features extracted from multispectral images of spinach seeds was investigated. The objective has been...... to discriminate between different seed sizes, as well as to predict germination ability and germ length. Images of 300 seeds including small, medium, and large seeds were taken, and the seeds were examined for germination ability and germ length. PLS-DA loadings plots were used to reduce the multidimensional...

  13. Adaptive restoration of a partially coherent blurred image using an all-optical feedback interferometer with a liquid-crystal device.

    Science.gov (United States)

    Shirai, Tomohiro; Barnes, Thomas H

    2002-02-01

    A liquid-crystal adaptive optics system using all-optical feedback interferometry is applied to partially coherent imaging through a phase disturbance. A theoretical analysis based on the propagation of the cross-spectral density shows that the blurred image due to the phase disturbance can be restored, in principle, irrespective of the state of coherence of the light illuminating the object. Experimental verification of the theory has been performed for two cases when the object to be imaged is illuminated by spatially coherent light originating from a He-Ne laser and by spatially incoherent white light from a halogen lamp. We observed in both cases that images blurred by the phase disturbance were successfully restored, in agreement with the theory, immediately after the adaptive optics system was activated. The origin of the deviation of the experimental results from the theory, together with the effect of the feedback misalignment inherent in our optical arrangement, is also discussed.

  14. When structure affects function--the need for partial volume effect correction in functional and resting state magnetic resonance imaging studies.

    Science.gov (United States)

    Dukart, Juergen; Bertolino, Alessandro

    2014-01-01

    Both functional and also more recently resting state magnetic resonance imaging have become established tools to investigate functional brain networks. Most studies use these tools to compare different populations without controlling for potential differences in underlying brain structure which might affect the functional measurements of interest. Here, we adapt a simulation approach combined with evaluation of real resting state magnetic resonance imaging data to investigate the potential impact of partial volume effects on established functional and resting state magnetic resonance imaging analyses. We demonstrate that differences in the underlying structure lead to a significant increase in detected functional differences in both types of analyses. Largest increases in functional differences are observed for highest signal-to-noise ratios and when signal with the lowest amount of partial volume effects is compared to any other partial volume effect constellation. In real data, structural information explains about 25% of within-subject variance observed in degree centrality--an established resting state connectivity measurement. Controlling this measurement for structural information can substantially alter correlational maps obtained in group analyses. Our results question current approaches of evaluating these measurements in diseased population with known structural changes without controlling for potential differences in these measurements.

  15. [Percutaneous closure of the patent ductus arteriosus in children with the Amplatzer Duct Occluder II].

    Science.gov (United States)

    Parra-Bravo, José Rafael; Osuna-Izaguirre, Manuel Alfredo; Beirana-Palencia, Luisa; Gálvez-Cancino, Franco; Martínez-Monterrosas, Christian; Lazo-Cárdenas, César; Reyes-Vargas, César

    2014-01-01

    In the last decades, several devices have been used for the percutaneous closure of patent ductus arteriosus, with its own limitations and risks. The Amplatzer Duct Occluder II has been designed to overcome those limitations and reduce risks. We described our initial series of patients who underwent percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder II, emphasis on the technical aspects of the procedure. We reviewed the clinical records of 9 patients with patent ductus arteriosus who underwent percutaneous closure with the Amplatzer Duct Occluder II. Median age was 24 months (range 8-51 months) and the median weight was 10.7kg (range 6-16.3kg). The minimal ductus arteriosus diameter was 2.7mm (1-5mm). Implantation was successful in all cases. The devices most commonly used (33.3%) were the dimensions 4-4mm (3 patients), in 2 patients were used 3-4mm and in the rest of the patients were employed occluder other sizes. Four cases showed slight residual flow immediately after implantation. Total closure was achieved in 24h in 8 of 9 patients (89%). There was no embolization of the occluder or deaths during the procedure and we only observed one minor complication. The Amplatzer Duct Occluder II in this series was effective in 89% of the patients at 24hs after the procedure and 100% follow-up. The implantation was safe and no major complications were observed. The occlusion rate is comparable to those reported for the Amplatzer Duct Occluder I. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  16. Closure of large patent ductus arteriosus using the Amplatzer Septal Occluder.

    Science.gov (United States)

    García-Montes, José A; Camacho-Castro, Anahí; Sandoval-Jones, Juan P; Buendía-Hernández, Alfonso; Calderón-Colmenero, Juan; Patiño-Bahena, Emilia; Zabal, Carlos

    2015-03-01

    Percutaneous closure of patent ductus arteriosus has become the treatment of choice in many centres. In patients with large ducts and pulmonary hypertension, transcatheter closure has been achieved with success using the Amplatzer Duct Occluder or even the Amplatzer Muscular Ventricular Septal Defect Occluder. We present a series of 17 patients with large and hypertensive ductus arteriosus who were treated with an Amplatzer Septal Occluder. The group had 11 female patients (64.7%) and a mean age of 18.6±12.1 years. The haemodynamic and anatomical data are as follows: pulmonary artery systolic pressure 71.3±31.8 mmHg, pulmonary to systemic flow ratio 3.14±1.36, ductal diameter at the pulmonary end 12.5±3.8 mm, and at the aortic end 20.2±7.7 mm; 14 cases (82.3%) had type A ducts. In 11 patients, we began the procedure using a different device - six with duct occluder and five with ventricular septal occluder - and it was changed because of device embolisation in six (35.3%). All septal occluders were delivered successfully. Residual shunt was moderate in six patients (35.3%), mild in eight (47%), trivial in two (11.8%), and no shunt in one (5.9%). Pulmonary systolic pressure decreased to 48.9±10.8 mmHg after occlusion (p=0.0015). Follow-up in 15 patients (88.2%) for 28.4±14.4 months showed complete closure in all cases but one, and continuous decrease of the pulmonary systolic pressure to 31.4±10.5 mmHg. No complications at follow-up have been reported. The Amplatzer Septal Occluder is a good alternative to percutaneously treat large and hypertensive ductus arteriosus.

  17. Resolution of clinical symptoms after reopening of an occluded inferior petrosal sinus in a patient with a cavernous sinus dural arteriovenous fistula. A case report.

    Science.gov (United States)

    Kojima, A; Onozuka, S; Kinoshita, Y

    2013-03-01

    We describe a rare case with a cavernous sinus (CS) dural arteriovenous fistula (DAVF) in which the clinical symptoms disappeared after the patient underwent reopening of an occluded inferior petrosal sinus (IPS). A 66-year-old woman presented with increased intraocular pressure, chemosis, and proptosis on the left side. Angiography demonstrated a left CS DAVF supplied by the dural branches of bilateral internal carotid arteries. The shunt flow was directed to the superior and inferior ophthalmic veins, while the bilateral IPSs were not opacified. Accordingly, a transvenous embolization of the fistula was attempted. Although the microcatheter was navigated to the cavernous sinus through the occluded left IPS, obliteration of the fistula was unsuccessful because of the failure of superselective catheterization at the fistulous point. However, the final image demonstrated the development of an antegrade shunt flow through the left IPS to the internal jugular vein and disappearance of the retrograde reflux to the superior and inferior ophthalmic veins. The patient's clinical symptoms immediately resolved after the operation, and the symptoms have not recurred during a one-year follow-up period. Inappropriate transvenous embolization of CS DAVFs can result in vascular complications arising from the unintentional redistribution of shunt flow. The present case illustrates that the disappearance of retrograde shunt flow to the ophthalmic veins after reopening of the occluded IPS may be sufficient if a superselective approach fails or is anticipated to result only in an incomplete embolization of the fistulous point.

  18. Spectral Mixture Analysis: Linear and Semi-parametric Full and Iterated Partial Unmixing in Multi- and Hyperspectral Image Data

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg

    2001-01-01

    ) and non-negative least squares (NNLS), and the partial unmixing methods orthogonal subspace projection (OSP), constrained energy minimization (CEM) and an eigenvalue formulation alternative are dealt with. The solution to the eigenvalue formulation alternative proves to be identical to the CEM solution....... The matrix inversion involved in CEM can be avoided by working on (a subset of) orthogonally transformed data such as signal maximum autocorrelation factors, MAFs, or signal minimum noise fractions, MNFs. This will also cause the partial unmixing result to be independent of the noise isolated in the MAF....../MNFs not included in the analysis. CEM and the eigenvalue formulation alternative enable us to perform partial unmixing when we know one desired end-member spectrum only and not the full set of end-member spectra. This is an advantage over full unmixing and OSP. The eigenvalue formulation of CEM inspires us...

  19. Time course of spatial and feature selective attention for partly-occluded objects.

    Science.gov (United States)

    Kasai, Tetsuko; Takeya, Ryuji

    2012-07-01

    Attention selects objects/groups as the most fundamental units, and this may be achieved by an attention-spreading mechanism. Previous event-related potential (ERP) studies have found that attention-spreading is reflected by a decrease in the N1 spatial attention effect. The present study tested whether the electrophysiological attention effect is associated with the perception of object unity or amodal completion through the use of partly-occluded objects. ERPs were recorded in 14 participants who were required to pay attention to their left or right visual field and to press a button for a target shape in the attended field. Bilateral stimuli were presented rapidly, and were separated, connected, or connected behind an occluder. Behavioral performance in the connected and occluded conditions was worse than that in the separated condition, indicating that attention spread over perceptual object representations after amodal completion. Consistently, the late N1 spatial attention effect (180-220 ms post-stimulus) and the early phase (230-280 ms) of feature selection effects (target N2) at contralateral sites decreased, equally for the occluded and connected conditions, while the attention effect in the early N1 latency (140-180 ms) shifted most positively for the occluded condition. These results suggest that perceptual organization processes for object recognition transiently modulate spatial and feature selection processes in the visual cortex. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. A comparison of five partial volume correction methods for Tau and Amyloid PET imaging with [18F]THK5351 and [11C]PIB.

    Science.gov (United States)

    Shidahara, Miho; Thomas, Benjamin A; Okamura, Nobuyuki; Ibaraki, Masanobu; Matsubara, Keisuke; Oyama, Senri; Ishikawa, Yoichi; Watanuki, Shoichi; Iwata, Ren; Furumoto, Shozo; Tashiro, Manabu; Yanai, Kazuhiko; Gonda, Kohsuke; Watabe, Hiroshi

    2017-08-01

    To suppress partial volume effect (PVE) in brain PET, there have been many algorithms proposed. However, each methodology has different property due to its assumption and algorithms. Our aim of this study was to investigate the difference among partial volume correction (PVC) method for tau and amyloid PET study. We investigated two of the most commonly used PVC methods, Müller-Gärtner (MG) and geometric transfer matrix (GTM) and also other three methods for clinical tau and amyloid PET imaging. One healthy control (HC) and one Alzheimer's disease (AD) PET studies of both [ 18 F]THK5351 and [ 11 C]PIB were performed using a Eminence STARGATE scanner (Shimadzu Inc., Kyoto, Japan). All PET images were corrected for PVE by MG, GTM, Labbé (LABBE), Regional voxel-based (RBV), and Iterative Yang (IY) methods, with segmented or parcellated anatomical information processed by FreeSurfer, derived from individual MR images. PVC results of 5 algorithms were compared with the uncorrected data. In regions of high uptake of [ 18 F]THK5351 and [ 11 C]PIB, different PVCs demonstrated different SUVRs. The degree of difference between PVE uncorrected and corrected depends on not only PVC algorithm but also type of tracer and subject condition. Presented PVC methods are straight-forward to implement but the corrected images require careful interpretation as different methods result in different levels of recovery.

  1. Effects of injection timing on fluid flow characteristics of partially premixed combustion based on high-speed particle image velocimetry

    NARCIS (Netherlands)

    Izadi Najafabadi, M.; Tanov, S.; Wang, H.; Somers, L.M.T.; Johansson, B.; Dam, N.J.

    2017-01-01

    Partially premixed combustion (PPC) is a promising combustion concept to meet the increasing demands of emission legislation and to improve fuel efficiency. Longer ignition delay of PPC in comparison with conventional diesel combustion provide better fuel/air mixture which decreases soot and NOx

  2. A method for partial volume correction of PET-imaged tumor heterogeneity using expectation maximization with a spatially varying point spread function

    International Nuclear Information System (INIS)

    Barbee, David L; Holden, James E; Nickles, Robert J; Jeraj, Robert; Flynn, Ryan T

    2010-01-01

    Tumor heterogeneities observed in positron emission tomography (PET) imaging are frequently compromised by partial volume effects which may affect treatment prognosis, assessment or future implementations such as biologically optimized treatment planning (dose painting). This paper presents a method for partial volume correction of PET-imaged heterogeneous tumors. A point source was scanned on a GE Discovery LS at positions of increasing radii from the scanner's center to obtain the spatially varying point spread function (PSF). PSF images were fit in three dimensions to Gaussian distributions using least squares optimization. Continuous expressions were devised for each Gaussian width as a function of radial distance, allowing for generation of the system PSF at any position in space. A spatially varying partial volume correction (SV-PVC) technique was developed using expectation maximization (EM) and a stopping criterion based on the method's correction matrix generated for each iteration. The SV-PVC was validated using a standard tumor phantom and a tumor heterogeneity phantom and was applied to a heterogeneous patient tumor. SV-PVC results were compared to results obtained from spatially invariant partial volume correction (SINV-PVC), which used directionally uniform three-dimensional kernels. SV-PVC of the standard tumor phantom increased the maximum observed sphere activity by 55 and 40% for 10 and 13 mm diameter spheres, respectively. Tumor heterogeneity phantom results demonstrated that as net changes in the EM correction matrix decreased below 35%, further iterations improved overall quantitative accuracy by less than 1%. SV-PVC of clinically observed tumors frequently exhibited changes of ±30% in regions of heterogeneity. The SV-PVC method implemented spatially varying kernel widths and automatically determined the number of iterations for optimal restoration, parameters which are arbitrarily chosen in SINV-PVC. Comparing SV-PVC to SINV-PVC demonstrated

  3. Quantifying [{sup 18}F]fluorodeoxyglucose uptake in the arterial wall: the effects of dual time-point imaging and partial volume effect correction

    Energy Technology Data Exchange (ETDEWEB)

    Blomberg, Bjoern A. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark); Bashyam, Arjun; Ramachandran, Abhinay; Gholami, Saeid; Houshmand, Sina; Salavati, Ali; Werner, Tom; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); University of Groningen, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen (Netherlands)

    2015-08-15

    The human arterial wall is smaller than the spatial resolution of current positron emission tomographs. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake. We evaluated the impact of a novel method for partial volume effect (PVE) correction with contrast-enhanced CT (CECT) assistance on quantification of arterial wall {sup 18}F-FDG uptake at different imaging time-points. Ten subjects were assessed by CECT imaging and dual time-point PET/CT imaging at approximately 60 and 180 min after {sup 18}F-FDG administration. For both time-points, uptake of {sup 18}F-FDG was determined in the aortic wall by calculating the blood pool-corrected maximum standardized uptake value (cSUV{sub MAX}) and cSUV{sub MEAN}. The PVE-corrected SUV{sub MEAN} (pvcSUV{sub MEAN}) was also calculated using {sup 18}F-FDG PET/CT and CECT images. Finally, corresponding target-to-background ratios (TBR) were calculated. At 60 min, pvcSUV{sub MEAN} was on average 3.1 times greater than cSUV{sub MAX} (P <.0001) and 8.5 times greater than cSUV{sub MEAN} (P <.0001). At 180 min, pvcSUV{sub MEAN} was on average 2.6 times greater than cSUV{sub MAX} (P <.0001) and 6.6 times greater than cSUV{sub MEAN} (P <.0001). This study demonstrated that CECT-assisted PVE correction significantly influences quantification of arterial wall {sup 18}F-FDG uptake. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake with PET. (orig.)

  4. Animal experimental research of the endothelialization of home-made atrial septal defect occluder device

    International Nuclear Information System (INIS)

    Chen Mingwu; Zhou Aiqing; Li Feng; Gao Wei; Yu Zhiqing; Tang Ning; Zhang Lan

    2003-01-01

    Objective: To evaluate the endothelialization of Chinese nitinol atrial septal defect occluder device. Methods: Atrial septal defect with controllable size was created by the Brockenborough needle and Rashkind balloon atrial septostomy, the occluder devices were implanted in six piglets (mean weight 7.5 kg). Two pigs were killed each time after 1 month, 3 months and 6 months after the device implantation and then the explanted devices were examined by scanning electron microscope (SEM). Results: The devices were found covering with collagen fibrosis together with diffuse endothelial cells spreading over the primer 1 month after implantation. The implants were covered mostly by neointima 3 months after implantation and completely covered by confluent endothelial cells 6 months after the implantation. Endothelial cells were not found on the smooth marker band at 3 months, however, did exist by 6 months. Conclusions: Home-made atrial septal defect occluder devices were mostly endothelialised 3 months after the implantation and did completely at 6 months

  5. Distribution and Determinants of Myocardial Perfusion Grade Following Late Mechanical Recanalization of Occluded Infarct-Related Arteries Postmyocardial Infarction: A Report From the Occluded Artery Trial

    Science.gov (United States)

    Jorapur, Vinod; Steigen, Terje K.; Buller, Christopher E.; Dẑavík, Vladimír; Webb, John G.; Strauss, Bradley H.; Yeoh, Eunice E.S.; Kurray, Peter; Sokalski, Leszek; Machado, Mauricio C.; Kronsberg, Shari S.; Lamas, Gervasio A.; Hochman, Judith S.; John Mancini, G.B.

    2010-01-01

    Objective To evaluate the distribution and determinants of myocardial perfusion grade (MPG) following late recanalization of persistently occluded infarct-related arteries (IRA). Background MPG reflects microvascular integrity. It is an independent prognostic factor following myocardial infarction, but has been studied mainly in the setting of early reperfusion. The occluded artery trial (OAT) enrolled stable patients with persistently occluded IRAs beyond 24 hr and up to 28 days post-MI. Methods Myocardial blush was assessed using TIMI MPG grading in 261 patients with TIMI 3 epicardial flow following IRA PCI. Patients demonstrating impaired (0–1) versus preserved (2–3) MPG were compared with regard to baseline clinical and pre-PCI angiographic characteristics. Results Impaired MPG was observed in 60 of 261 patients (23%). By univariate analysis, impaired MPG was associated with failed fibrinolytic therapy, higher heart rate, lower systolic blood pressure, lower ejection fraction, LAD occlusion, absence of collaterals (P < 0.01) and ST elevation MI, lower diastolic blood pressure, and higher systolic sphericity index (P < 0.05). By multivariable analysis, higher heart rate, LAD occlusion, absence of collaterals and higher systolic sphericity index (P < 0.01), and lower systolic blood pressure (P < 0.05) were independently associated with impaired MPG. Conclusion Preserved microvascular integrity was present in a high proportion of patients following late recanalization of occluded IRAs post-MI. Presence of collaterals was independently associated with preserved MPG and likely accounted for the high frequency of preserved myocardial perfusion in this clinical setting. Impaired MPG was associated with baseline clinical and angiographic features consistent with larger infarct size. PMID:18798327

  6. Smaller calcite lattice deformation caused by occluded organic material in coccoliths than in mollusk shell

    DEFF Research Database (Denmark)

    Frølich, Simon; Sørensen, Henning Osholm; Hakim, Sepideh Sadat

    2015-01-01

    The growth and nucleation of biominerals are directed and affected by associated biological molecules. In this paper, we investigate the influence of occluded biomolecules on biogenic calcite from the coccolithophorid Pleurochrysis carterae and from chalk, a rock composed predominantly of fossil....... Two heating cycles allow us to differentiate the effects of thermal agitation and organic molecules. Single peak analysis and Rietveld refinement were combined to show significant differences resulting from the occluded biomolecules on the mineral phase in biogenic calcite in the mollusk shell...

  7. View-sharing in keyhole imaging: Partially compressed central k-space acquisition in time-resolved MRA at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Hadizadeh, Dariusch R., E-mail: Dariusch.Hadizadeh@ukb.uni-bonn.de [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Philips Healthcare, Best (Netherlands); Beck, Gabriele; Geerts, Liesbeth [Philips Healthcare, Best (Netherlands); Kukuk, Guido M. [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Bostroem, Azize [Department of Neurosurgery, Sigmund-Freud-Strasse 25, 53127 Bonn, Deutschland (Germany); Urbach, Horst; Schild, Hans H.; Willinek, Winfried A. [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany)

    2011-11-15

    Introduction: Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CEMRA) of the intracranial vasculature has proved its clinical value for the evaluation of cerebral vascular disease in cases where both flow hemodynamics and morphology are important. The purpose of this study was to evaluate a combination of view-sharing with keyhole imaging to increase spatial and temporal resolution of time-resolved CEMRA at 3.0 T. Methods: Alternating view-sharing was combined with randomly segmented k-space ordering, keyhole imaging, partial Fourier and parallel imaging (4DkvsMRA). 4DkvsMRA was evaluated using varying compression factors (80-100) resulting in spatial resolutions ranging from (1.1 x 1.1 x 1.4) to (0.96 x 0.96 x 0.95) mm{sup 3} and temporal resolutions ranging from 586 ms/dynamic scan - 288 ms/dynamic scan in three protocols in 10 healthy volunteers and seven patients (17 subjects). DSA correlation was available in four patients with cerebral arteriovenous malformations (cAVMs) and one patient with cerebral teleangiectasia. Results: 4DkvsMRA was successfully performed in all subjects and showed clear depiction of arterial and venous phases with diagnostic image quality. At the maximum view-sharing compression factor (=100), a 'flickering' artefact was observed. Conclusion: View-sharing in keyhole imaging allows for increased spatial and temporal resolution in time-resolved MRA.

  8. View-sharing in keyhole imaging: Partially compressed central k-space acquisition in time-resolved MRA at 3.0 T

    International Nuclear Information System (INIS)

    Hadizadeh, Dariusch R.; Gieseke, Juergen; Beck, Gabriele; Geerts, Liesbeth; Kukuk, Guido M.; Bostroem, Azize; Urbach, Horst; Schild, Hans H.; Willinek, Winfried A.

    2011-01-01

    Introduction: Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CEMRA) of the intracranial vasculature has proved its clinical value for the evaluation of cerebral vascular disease in cases where both flow hemodynamics and morphology are important. The purpose of this study was to evaluate a combination of view-sharing with keyhole imaging to increase spatial and temporal resolution of time-resolved CEMRA at 3.0 T. Methods: Alternating view-sharing was combined with randomly segmented k-space ordering, keyhole imaging, partial Fourier and parallel imaging (4DkvsMRA). 4DkvsMRA was evaluated using varying compression factors (80-100) resulting in spatial resolutions ranging from (1.1 x 1.1 x 1.4) to (0.96 x 0.96 x 0.95) mm 3 and temporal resolutions ranging from 586 ms/dynamic scan - 288 ms/dynamic scan in three protocols in 10 healthy volunteers and seven patients (17 subjects). DSA correlation was available in four patients with cerebral arteriovenous malformations (cAVMs) and one patient with cerebral teleangiectasia. Results: 4DkvsMRA was successfully performed in all subjects and showed clear depiction of arterial and venous phases with diagnostic image quality. At the maximum view-sharing compression factor (=100), a 'flickering' artefact was observed. Conclusion: View-sharing in keyhole imaging allows for increased spatial and temporal resolution in time-resolved MRA.

  9. Coupling 2D/3D registration method and statistical model to perform 3D reconstruction from partial x-rays images data.

    Science.gov (United States)

    Cresson, T; Chav, R; Branchaud, D; Humbert, L; Godbout, B; Aubert, B; Skalli, W; De Guise, J A

    2009-01-01

    3D reconstructions of the spine from a frontal and sagittal radiographs is extremely challenging. The overlying features of soft tissues and air cavities interfere with image processing. It is also difficult to obtain information that is accurate enough to reconstruct complete 3D models. To overcome these problems, the proposed method efficiently combines the partial information contained in two images from a patient with a statistical 3D spine model generated from a database of scoliotic patients. The algorithm operates through two simultaneous iterating processes. The first one generates a personalized vertebra model using a 2D/3D registration process with bone boundaries extracted from radiographs, while the other one infers the position and the shape of other vertebrae from the current estimation of the registration process using a statistical 3D model. Experimental evaluations have shown good performances of the proposed approach in terms of accuracy and robustness when compared to CT-scan.

  10. Optimization of CMOS image sensor utilizing variable temporal multisampling partial transfer technique to achieve full-frame high dynamic range with superior low light and stop motion capability

    Science.gov (United States)

    Kabir, Salman; Smith, Craig; Armstrong, Frank; Barnard, Gerrit; Schneider, Alex; Guidash, Michael; Vogelsang, Thomas; Endsley, Jay

    2018-03-01

    Differential binary pixel technology is a threshold-based timing, readout, and image reconstruction method that utilizes the subframe partial charge transfer technique in a standard four-transistor (4T) pixel CMOS image sensor to achieve a high dynamic range video with stop motion. This technology improves low light signal-to-noise ratio (SNR) by up to 21 dB. The method is verified in silicon using a Taiwan Semiconductor Manufacturing Company's 65 nm 1.1 μm pixel technology 1 megapixel test chip array and is compared with a traditional 4 × oversampling technique using full charge transfer to show low light SNR superiority of the presented technology.

  11. Transcaval TIPS in patients with failed revision of occluded previous TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Chang Kyu; Kim, Yong Joo; Shin, Tae Beom; Park, Hyo Yong; Kim, Tae Hun; Kang, Duk Sik [Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2001-12-01

    To determine the feasibility of transcaval transjugular intrahepatic portosystemic shunt (TIPS) in patients with occluded previous TIPS. Between February 1996 and December 2000 we performed five transcaval TIPS procedures in four patients with recurrent gastric cardiac variceal bleeding. All four had occluded TIPS, which was between the hepatic and portal vein. The interval between initial TIPS placement and revisional procedures with transcaval TIPS varied between three and 31 months; one patient underwent transcaval TIPS twice, with a 31-month interval. After revision of the occluded shunt failed, direct cavoportal puncture at the retrohepatic segment of the IVC was attempted. Transcaval TIPS placement was technically successful in all cases. In three, tractography revealed slight leakage of contrast materials into hepatic subcapsular or subdiaphragmatic pericaval space. There was no evidence of propagation of extravasated contrast materials through the retroperitoneal space or spillage into the peritoneal space. After the tract was dilated by a bare stent, no patient experienced trans-stent bleeding and no serious procedure-related complications occurred. After successful shunt creation, variceal bleeding ceased in all patients. Transcaval TIPS placement is an effective and safe alternative treatment in patients with occluded previous TIPS and no hepatic veins suitable for new TIPS.

  12. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder

    Directory of Open Access Journals (Sweden)

    Er-Ping Xi

    2012-11-01

    Full Text Available OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen Co., LTD, Guangdong, China utilizing standard techniques. RESULTS: Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. CONCLUSION: Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.

  13. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder.

    Science.gov (United States)

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-11-01

    Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.

  14. Treatment of Occluded Distal Splenorenal Shunts with Endovascular Stents: A Report of Two Cases

    International Nuclear Information System (INIS)

    Lopez-Medina, Antonio; Peiro, Javier; Gonzalez de Garay, Miguel; Antonana, Miguel A.; Sustacha, Jon; Grande, Domingo

    2001-01-01

    Surgical treatment of an occluded or stenotic portosystemic shunt is difficult and carries a high risk of mortality. We report two cases of early thrombosis of distal splenorenal shunt (DSRS) successfully treated by transcatheter recanalization and stent placement. At 18-month follow-up, the patients remained asymptomatic and control venograms showed continued patency of the shunt with no evidence of stenosis or collaterals

  15. 18 CFR 270.302 - Occluded natural gas produced from coal seams.

    Science.gov (United States)

    2010-04-01

    ... produced from coal seams. 270.302 Section 270.302 Conservation of Power and Water Resources FEDERAL ENERGY... produced from coal seams. A person seeking a determination that natural gas is occluded natural gas produced from coal seams must file an application with the jurisdictional agency which contains the...

  16. A Randomized Controlled Trial of Two Semi-Occluded Vocal Tract Voice Therapy Protocols

    Science.gov (United States)

    Kapsner-Smith, Mara R.; Hunter, Eric J.; Kirkham, Kimberly; Cox, Karin; Titze, Ingo R.

    2015-01-01

    Purpose: Although there is a long history of use of semi-occluded vocal tract gestures in voice therapy, including phonation through thin tubes or straws, the efficacy of phonation through tubes has not been established. This study compares results from a therapy program on the basis of phonation through a flow-resistant tube (FRT) with Vocal…

  17. Effect of partial volume correction on muscarinic cholinergic receptor imaging with single-photon emission tomography in patients with temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Weckesser, M.; Ziemons, K.; Griessmeier, M.; Sonnenberg, F.; Langen, K.J.; Mueller-Gaertner, H.W.; Hufnagel, A.; Elger, C.E.; Hacklaender, T.; Holschbach, M.

    1997-01-01

    Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [ 123 I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration. (orig.). With 2 figs., 2 tabs

  18. PET imaging of thin objects: measuring the effects of positron range and partial-volume averaging in the leaf of Nicotiana tabacum

    Energy Technology Data Exchange (ETDEWEB)

    Alexoff, David L., E-mail: alexoff@bnl.gov; Dewey, Stephen L.; Vaska, Paul; Krishnamoorthy, Srilalan; Ferrieri, Richard; Schueller, Michael; Schlyer, David J.; Fowler, Joanna S.

    2011-02-15

    Introduction: PET imaging in plants is receiving increased interest as a new strategy to measure plant responses to environmental stimuli and as a tool for phenotyping genetically engineered plants. PET imaging in plants, however, poses new challenges. In particular, the leaves of most plants are so thin that a large fraction of positrons emitted from PET isotopes ({sup 18}F, {sup 11}C, {sup 13}N) escape while even state-of-the-art PET cameras have significant partial-volume errors for such thin objects. Although these limitations are acknowledged by researchers, little data have been published on them. Methods: Here we measured the magnitude and distribution of escaping positrons from the leaf of Nicotiana tabacum for the radionuclides {sup 18}F, {sup 11}C and {sup 13}N using a commercial small-animal PET scanner. Imaging results were compared to radionuclide concentrations measured from dissection and counting and to a Monte Carlo simulation using GATE (Geant4 Application for Tomographic Emission). Results: Simulated and experimentally determined escape fractions were consistent. The fractions of positrons (mean{+-}S.D.) escaping the leaf parenchyma were measured to be 59{+-}1.1%, 64{+-}4.4% and 67{+-}1.9% for {sup 18}F, {sup 11}C and {sup 13}N, respectively. Escape fractions were lower in thicker leaf areas like the midrib. Partial-volume averaging underestimated activity concentrations in the leaf blade by a factor of 10 to 15. Conclusions: The foregoing effects combine to yield PET images whose contrast does not reflect the actual activity concentrations. These errors can be largely corrected by integrating activity along the PET axis perpendicular to the leaf surface, including detection of escaped positrons, and calculating concentration using a measured leaf thickness.

  19. Early postoperative cartilage evaluation by magnetic resonance imaging using T2 mapping after arthroscopic partial medial meniscectomy.

    Science.gov (United States)

    Kato, Kammei; Arai, Yuji; Ikoma, Kazuya; Nakagawa, Shuji; Inoue, Hiroaki; Kan, Hiroyuki; Matsuki, Tomohiro; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2015-12-01

    This study was performed to quantitatively evaluate postoperative changes in cartilage by T2 mapping after arthroscopic partial medial meniscectomy. The study enrolled 17 patients with 20 knees that underwent arthroscopic partial medial meniscectomy. MRI was performed preoperatively and at six months postoperatively, with subjects evaluated by T2 mapping of the central part of the medial condyle of the femur in the sagittal plane. Regions of interest (ROIs) were set at 10 points between the point of intersection of the anatomical axis of the femur and the articular surface of the medial condyle and posterior area approximately 90 degrees to the anatomical axis. Pre- and postoperative T2 values at each ROI were evaluated. Postoperative T2 values were significantly longer than preoperative values at approximately 20, 30, 40, and 50 degrees to the anatomical axis of the femur. The maximum change between pre- and postoperative T2 values was +6.65% at 30 degrees to the anatomical axis. Mechanical stress at positions approximately 20, 30, 40, and 50 degrees relative to the anatomical axis of the femur increased soon after arthroscopic medial meniscectomy. These findings indicate the start of degeneration, via disorganization of collagen arrays, of the articular cartilage and increased water content. Copyright © 2015. Published by Elsevier Inc.

  20. Impact of motion compensation and partial volume correction for 18F-NaF PET/CT imaging of coronary plaque

    Science.gov (United States)

    Cal-González, J.; Tsoumpas, C.; Lassen, M. L.; Rasul, S.; Koller, L.; Hacker, M.; Schäfers, K.; Beyer, T.

    2018-01-01

    Recent studies have suggested that 18F-NaF-PET enables visualization and quantification of plaque micro-calcification in the coronary tree. However, PET imaging of plaque calcification in the coronary arteries is challenging because of the respiratory and cardiac motion as well as partial volume effects. The objective of this work is to implement an image reconstruction framework, which incorporates compensation for respiratory as well as cardiac motion (MoCo) and partial volume correction (PVC), for cardiac 18F-NaF PET imaging in PET/CT. We evaluated the effect of MoCo and PVC on the quantification of vulnerable plaques in the coronary arteries. Realistic simulations (Biograph TPTV, Biograph mCT) and phantom acquisitions (Biograph mCT) were used for these evaluations. Different uptake values in the calcified plaques were evaluated in the simulations, while three ‘plaque-type’ lesions of 36, 31 and 18 mm3 were included in the phantom experiments. After validation, the MoCo and PVC methods were applied in four pilot NaF-PET patient studies. In all cases, the MoCo-based image reconstruction was performed using the STIR software. The PVC was obtained from a local projection (LP) method, previously evaluated in preclinical and clinical PET. The results obtained show a significant increase of the measured lesion-to-background ratios (LBR) in the MoCo  +  PVC images. These ratios were further enhanced when using directly the tissue-activities from the LP method, making this approach more suitable for the quantitative evaluation of coronary plaques. When using the LP method on the MoCo images, LBR increased between 200% and 1119% in the simulated data, between 212% and 614% in the phantom experiments and between 46% and 373% in the plaques with positive uptake observed in the pilot patients. In conclusion, we have built and validated a STIR framework incorporating MoCo and PVC for 18F-NaF PET imaging of coronary plaques. First results indicate an improved

  1. Experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype for partial breast irradiation

    International Nuclear Information System (INIS)

    Ravi, Ananth; Caldwell, Curtis B.; Pignol, Jean-Philippe

    2008-01-01

    Previously, our team used Monte Carlo simulation to demonstrate that a gamma camera could potentially be used as an online image guidance device to visualize seeds during permanent breast seed implant procedures. This could allow for intraoperative correction if seeds have been misplaced. The objective of this study is to describe an experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype. The OGIPSI device is intended to be able to detect a seed misplacement of 5 mm or more within an imaging time of 2 min or less. The device was constructed by fitting a custom built brass collimator (16 mm height, 0.65 mm hole pitch, 0.15 mm septal thickness) on a 64 pixel linear array CZT detector (eValuator-2000, eV Products, Saxonburg, PA). Two-dimensional projection images of seed distributions were acquired by the use of a digitally controlled translation stage. Spatial resolution and noise characteristics of the detector were measured. The ability and time needed for the OGIPSI device to image the seeds and to detect cold spots was tested using an anthropomorphic breast phantom. Mimicking a real treatment plan, a total of 52 103 Pd seeds of 65.8 MBq each were placed on three different layers at appropriate depths within the phantom. The seeds were reliably detected within 30 s with a median error in localization of 1 mm. In conclusion, an OGIPSI device can potentially be used for image guidance of permanent brachytherapy applications in the breast and, possibly, other sites

  2. High-Speed Single Quantum Dot Imaging of Artificial Lipids in Live Cells Reveal Partial Hop Diffusion

    DEFF Research Database (Denmark)

    Lagerholm, B. Christoffer; Clausen, Mathias P.; Christensen, Eva Arnspang

    2010-01-01

    -81). These findings have yet to be independently confirmed. In this work, we show that high-speed single particle tracking with quantum dots(QDs)and using a standard wide-field fluorescence microscope and an EMCCD is possible at image acquisition rates of up to ~2000 Hz with an image integration time of ~0.5 msec....... The spatial precision in these experiments is ~40 nm (as determined from the standard deviation of repeated position measurements of an immobile QD on a cell). Using this system, we further show that an artificial lipid, biotin-cap-DPPE, inserted in a mouse embryo fibroblast (MEF), labeled with sAv-QD655...

  3. Closure of the patent ductus arteriosus with the Amplatzer Duct Occluder II: a clinical experience.

    Science.gov (United States)

    Karagöz, Tevfik; Akin, Alper; Ertuğrul, Ilker; Aykan, Hayrettin Hakan; Alehan, Dursun; Ozer, Sema; Ozkutlu, Süheyla

    2012-12-01

    The aim of our study was to share our clinical experience on cases with patent ductus arteriosus treated with the Amplatzer Duct Occluder II. Between 2008 and 2012, 26 of 31 patients with patent ductus arteriosus underwent successful transcatheter closure of patent ductus arteriosus using the Amplatzer Duct Occluder II. Mean age was 3.3 years and mean weight was 15.7 kilograms. The presence of a residual shunt, left pulmonary artery or aortic obstruction was explored by administering contrast material during the procedure. The patients were discharged 24 hours after the procedure. The procedure was successful in 26 of 31 patients and failed in five patients. According to the Krichenko classification, 26 patients had type A, one patient had type B and 4 patients had type C ductus. The mean narrowest ductus diameter was 3.2 mm and the mean ductus length was 6.7 mm. Complete angiographic occlusion occurred immediately after the procedure in 22 out of 26 patients in whom the ductus was closed successfully with the Amplatzer Duct Occluder II. Complete occlusion was achieved in the remaining patients with residual shunt one month after the procedure. The procedure was preceded by closure with an Amplatzer Duct Occluder I in two patients and an Amplatzer Vascular Plug I in one patient. Amplatzer Duct Occluder II is highly effective in transcatheter closure of patent ductus arteriosus. We think that an alternative closure device and alternative techniques can be attempted in patients with type C ductus. The success rate could increase with accumulating experience.

  4. Patent ductus arteriosus closure using Occlutech® Duct Occluder, experience in Port Elizabeth, South Africa.

    Science.gov (United States)

    Pepeta, Lungile; Greyling, Adele; Nxele, Mahlubandile Fintan; Makrexeni, Zongezile Masonwabe

    2017-01-01

    Percutaneous closure of patent ductus arteriosus (PDA) has become standard therapy. Experience with the Occlutech® Duct Occluder is limited. Data regarding ductal closure using Occlutech® Duct Occluder were reviewed and prospectively collected. Demographics, hemodynamic and angiographic characteristics, complications, and outcomes were documented. From March 2013 to June 2016, 65 patients (43 females and 22 males) underwent percutaneous closure of the PDA using Occlutech® Duct Occluder. The median age of the patients was 11 months (range, 1-454 months) and the median weight was 8.5 kg (range 2.5-78 kg). The mean pulmonary artery median pressure was 27 mmHg (range, 12-100 mmHg) and the QP: Qs ratio median was 1.8 (range, 1-7.5), with a pulmonary vascular resistance mean of 2.7 WU (standard deviation [SD] ±2.1). Thirty-two patients had Krichenko Type A duct (49%); 7, Type C (11%); 4, Type D (6%); and 22, Type E (34%). The ductal size (narrowest diameter at the pulmonic end) mean was 3.5 mm (SD ± 1.9 mm). The screening time mean was 17.3 min (SD ± 11.6). Out of 63 patients with successful closure of the PDA using Occlutech® Duct Occluder, there were 15 patients with small PDAs; 25 with moderate PDAs, and 23 with large PDAs. In one patient, the device dislodged to the descending aorta, and in two patients, to the right pulmonary artery immediately following deployment, with successful percutaneous (two) and surgical (one) retrieval. Complete ductal occlusion was achieved in all 63 patients on day one. The Occlutech® Duct Occluder is a safe and effective device for closure of ducts in appropriately selected patients.

  5. Effects of Injection Timing on Fluid Flow Characteristics of Partially Premixed Combustion Based on High-Speed Particle Image Velocimetry

    KAUST Repository

    Izadi Najafabadi, Mohammad; Tanov, Slavey; Wang, Hua; Somers, Bart; Johansson, Bengt; Dam, Nico

    2017-01-01

    behavior. The scope of the present study is to investigate the fluid flow characteristics of PPC at different injection timings. To this end, high-speed Particle Image Velocimetry (PIV) is implemented in a light-duty optical engine to measure fluid flow

  6. Two-step superresolution approach for surveillance face image through radial basis function-partial least squares regression and locality-induced sparse representation

    Science.gov (United States)

    Jiang, Junjun; Hu, Ruimin; Han, Zhen; Wang, Zhongyuan; Chen, Jun

    2013-10-01

    Face superresolution (SR), or face hallucination, refers to the technique of generating a high-resolution (HR) face image from a low-resolution (LR) one with the help of a set of training examples. It aims at transcending the limitations of electronic imaging systems. Applications of face SR include video surveillance, in which the individual of interest is often far from cameras. A two-step method is proposed to infer a high-quality and HR face image from a low-quality and LR observation. First, we establish the nonlinear relationship between LR face images and HR ones, according to radial basis function and partial least squares (RBF-PLS) regression, to transform the LR face into the global face space. Then, a locality-induced sparse representation (LiSR) approach is presented to enhance the local facial details once all the global faces for each LR training face are constructed. A comparison of some state-of-the-art SR methods shows the superiority of the proposed two-step approach, RBF-PLS global face regression followed by LiSR-based local patch reconstruction. Experiments also demonstrate the effectiveness under both simulation conditions and some real conditions.

  7. The value of magnetoencephalography for seizure-onset zone localization in magnetic resonance imaging-negative partial epilepsy.

    Science.gov (United States)

    Jung, Julien; Bouet, Romain; Delpuech, Claude; Ryvlin, Philippe; Isnard, Jean; Guenot, Marc; Bertrand, Olivier; Hammers, Alexander; Mauguière, François

    2013-10-01

    Surgical treatment of epilepsy is a challenge for patients with non-contributive brain magnetic resonance imaging. However, surgery is feasible if the seizure-onset zone is precisely delineated through intracranial electroencephalography recording. We recently described a method, volumetric imaging of epileptic spikes, to delineate the spiking volume of patients with focal epilepsy using magnetoencephalography. We postulated that the extent of the spiking volume delineated with volumetric imaging of epileptic spikes could predict the localizability of the seizure-onset zone by intracranial electroencephalography investigation and outcome of surgical treatment. Twenty-one patients with non-contributive magnetic resonance imaging findings were included. All patients underwent intracerebral electroencephalography investigation through stereotactically implanted depth electrodes (stereo-electroencephalography) and magnetoencephalography with delineation of the spiking volume using volumetric imaging of epileptic spikes. We evaluated the spatial congruence between the spiking volume determined by magnetoencephalography and the localization of the seizure-onset zone determined by stereo-electroencephalography. We also evaluated the outcome of stereo-electroencephalography and surgical treatment according to the extent of the spiking volume (focal, lateralized but non-focal or non-lateralized). For all patients, we found a spatial overlap between the seizure-onset zone and the spiking volume. For patients with a focal spiking volume, the seizure-onset zone defined by stereo-electroencephalography was clearly localized in all cases and most patients (6/7, 86%) had a good surgical outcome. Conversely, stereo-electroencephalography failed to delineate a seizure-onset zone in 57% of patients with a lateralized spiking volume, and in the two patients with bilateral spiking volume. Four of the 12 patients with non-focal spiking volumes were operated upon, none became seizure

  8. Length of Distal Resection Margin after Partial Mesorectal Excision for Upper Rectal Cancer Estimated by Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Bondeven, Peter; Hagemann-Madsen, Rikke Hjarnø; Bro, Lise

    BACKGROUND: Rectal cancer requires surgery for cure. Partial mesorectal excision (PME) is suggested for tumours in the upper rectum and implies transection of the mesorectum perpendicular to the bowel a minimum of 5 cm below the tumour. Reports have shown distal mesorectal tumour spread of up to 5...... cm from the primary tumour; therefore, guidelines for cancer of the upper rectum recommend PME with a distal resection margin (DRM) of at least 5 cm or total mesorectal excision (TME). PME exerts a hazard of removing less than 5 cm - leaving microscopic tumour cells that have spread in the mesorectum....... Studies at our department have shown inadequate DRM in 75 % of the patients estimated by post-operative MRI of the pelvis and by measurements of the histopathological specimen. Correspondingly, a higher rate of local recurrence in patients surgically treated with PME for rectal cancer - compared to TME...

  9. Use of images of ictal-inter-ictal SPECT subtraction superimposed on MRI in pharmaco-resistant partial epilepsies in infants

    International Nuclear Information System (INIS)

    Vera, P.; Kaminska, A.; Cieuta, C.; Mangin, F.; Frouin, V.; Dulac, O.; Chiron, C.

    1997-01-01

    To study the significance of ictal SPECT in the pre-surgical examination of infant epilepsies we have explored 16 infants aged 3 months to 18 years presenting partial pharmaco-resistant epilepsy. All of them have had an ictal SPECT under EEG - video recording than, two days after, an inter-ictal SPECT coupled to a 3D cerebral MRI. The perfusion tracer, the 99m Tc - ECD, was injected in average at 15 seconds after the outset of crisis. The image processing implied a matching of the two SPECT examinations by a 3D rigid superposition method, a normalization and than a inter-ictal-ictal image subtraction. Finally, the subtraction was matched and superimposed on the MRI. The SPECT subtraction image showed one or several centres of ictal hyper-output in 15 patients, while the separated visual ictal and inter-ictal images were contributory in 8 cases only. The 16. infant presented very short crises (<10 sec). In the cases when the outset point of crises could be established clinically (12 cases) and/or on EEG (8 cases) a hyper-output of concordant localization was recorded. In 5 infants who have had an electrocorticography, a concordance was obtained in all the cases except in an infant having very short crises the subtraction image did not show hyper-output. These preliminary results show that the ictal - inter-ictal SPECT subtraction images, adjusted on MRI, appears to be reliable in detecting the outset point of crises in infants and at the same time useful in guiding the positioning of intra-cranial electrodes prior to surgery intervention

  10. An efficient and secure partial image encryption for wireless multimedia sensor networks using discrete wavelet transform, chaotic maps and substitution box

    Science.gov (United States)

    Khan, Muazzam A.; Ahmad, Jawad; Javaid, Qaisar; Saqib, Nazar A.

    2017-03-01

    Wireless Sensor Networks (WSN) is widely deployed in monitoring of some physical activity and/or environmental conditions. Data gathered from WSN is transmitted via network to a central location for further processing. Numerous applications of WSN can be found in smart homes, intelligent buildings, health care, energy efficient smart grids and industrial control systems. In recent years, computer scientists has focused towards findings more applications of WSN in multimedia technologies, i.e. audio, video and digital images. Due to bulky nature of multimedia data, WSN process a large volume of multimedia data which significantly increases computational complexity and hence reduces battery time. With respect to battery life constraints, image compression in addition with secure transmission over a wide ranged sensor network is an emerging and challenging task in Wireless Multimedia Sensor Networks. Due to the open nature of the Internet, transmission of data must be secure through a process known as encryption. As a result, there is an intensive demand for such schemes that is energy efficient as well as highly secure since decades. In this paper, discrete wavelet-based partial image encryption scheme using hashing algorithm, chaotic maps and Hussain's S-Box is reported. The plaintext image is compressed via discrete wavelet transform and then the image is shuffled column-wise and row wise-wise via Piece-wise Linear Chaotic Map (PWLCM) and Nonlinear Chaotic Algorithm, respectively. To get higher security, initial conditions for PWLCM are made dependent on hash function. The permuted image is bitwise XORed with random matrix generated from Intertwining Logistic map. To enhance the security further, final ciphertext is obtained after substituting all elements with Hussain's substitution box. Experimental and statistical results confirm the strength of the anticipated scheme.

  11. Self-navigated 4D cartesian imaging of periodic motion in the body trunk using partial k-space compressed sensing.

    Science.gov (United States)

    Küstner, Thomas; Würslin, Christian; Schwartz, Martin; Martirosian, Petros; Gatidis, Sergios; Brendle, Cornelia; Seith, Ferdinand; Schick, Fritz; Schwenzer, Nina F; Yang, Bin; Schmidt, Holger

    2017-08-01

    To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A partial Fourier-like constraint compacts the sampling space to one half of k-space. The central k-space line is periodically acquired to allow an extraction of a self-navigated respiration signal used to populate a k-space of multiple breathing positions. The randomness of the acquisition (induced by periodic breathing pattern) yields a subsampled k-space that is reconstructed using compressed sensing. Local image evaluations (coefficient of variation and slope steepness through organs) reveal information about motion resolvability. Image quality is inspected by a blinded reading. Sequence and reconstruction method are made publicly available. The method is able to capture and reconstruct 4D images with high image quality and motion resolution within a short scan time of less than 2 min. These findings are supported by restricted-isometry-property analysis, local image evaluation, and blinded reading. The proposed method provides a clinical feasible setup to capture periodic respiratory motion with a fast acquisition protocol and can be extended by further surrogate signals to capture additional periodic motions. Retrospective parametrization allows for flexible tuning toward the targeted applications. Magn Reson Med 78:632-644, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Lack of benefit from percutaneous intervention of persistently occluded infarct arteries after the acute phase of myocardial infarction is time independent: insights from Occluded Artery Trial

    Science.gov (United States)

    Menon, Venu; Pearte, Camille A.; Buller, Christopher E.; Steg, Ph.Gabriel; Forman, Sandra A.; White, Harvey D.; Marino, Paolo N.; Katritsis, Demosthenes G.; Caramori, Paulo; Lasevitch, Ricardo; Loboz-Grudzien, Krystyna; Zurakowski, Aleksander; Lamas, Gervasio A.; Hochman, Judith S.

    2009-01-01

    Aims The Occluded Artery Trial (OAT) (n = 2201) showed no benefit for routine percutaneous intervention (PCI) (n = 1101) over medical therapy (MED) (n = 1100) on the combined endpoint of death, myocardial infarction (MI), and class IV heart failure (congestive heart failure) in stable post-MI patients with late occluded infarct-related arteries (IRAs). We evaluated the potential for selective benefit with PCI over MED for patients enrolled early in OAT. Methods and results We explored outcomes with PCI over MED in patients randomized to the ≤3 calendar days and ≤7 calendar days post-MI time windows. Earlier, times to randomization in OAT were associated with higher rates of the combined endpoint (adjusted HR 1.04/day: 99% CI 1.01–1.06; P < 0.001). The 48-month event rates for ≤3 days, ≤7 days post-MI enrolled patients were similar for PCI vs. MED for the combined and individual endpoints. There was no interaction between time to randomization defined as a continuous (P = 0.55) or categorical variable with a cut-point of 3 days (P = 0.98) or 7 days (P = 0.64) post-MI and treatment effect. Conclusion Consistent with overall OAT findings, patients enrolled in the ≤3 day and ≤7 day post-MI time windows derived no benefit with PCI over MED with no interaction between time to randomization and treatment effect. Our findings do not support routine PCI of the occluded IRA in trial-eligible patients even in the earliest 24–72 h time window. PMID:19028780

  13. Partial volume correction and image segmentation for accurate measurement of standardized uptake value of grey matter in the brain.

    Science.gov (United States)

    Bural, Gonca; Torigian, Drew; Basu, Sandip; Houseni, Mohamed; Zhuge, Ying; Rubello, Domenico; Udupa, Jayaram; Alavi, Abass

    2015-12-01

    Our aim was to explore a novel quantitative method [based upon an MRI-based image segmentation that allows actual calculation of grey matter, white matter and cerebrospinal fluid (CSF) volumes] for overcoming the difficulties associated with conventional techniques for measuring actual metabolic activity of the grey matter. We included four patients with normal brain MRI and fluorine-18 fluorodeoxyglucose (F-FDG)-PET scans (two women and two men; mean age 46±14 years) in this analysis. The time interval between the two scans was 0-180 days. We calculated the volumes of grey matter, white matter and CSF by using a novel segmentation technique applied to the MRI images. We measured the mean standardized uptake value (SUV) representing the whole metabolic activity of the brain from the F-FDG-PET images. We also calculated the white matter SUV from the upper transaxial slices (centrum semiovale) of the F-FDG-PET images. The whole brain volume was calculated by summing up the volumes of the white matter, grey matter and CSF. The global cerebral metabolic activity was calculated by multiplying the mean SUV with total brain volume. The whole brain white matter metabolic activity was calculated by multiplying the mean SUV for the white matter by the white matter volume. The global cerebral metabolic activity only reflects those of the grey matter and the white matter, whereas that of the CSF is zero. We subtracted the global white matter metabolic activity from that of the whole brain, resulting in the global grey matter metabolism alone. We then divided the grey matter global metabolic activity by grey matter volume to accurately calculate the SUV for the grey matter alone. The brain volumes ranged between 1546 and 1924 ml. The mean SUV for total brain was 4.8-7. Total metabolic burden of the brain ranged from 5565 to 9617. The mean SUV for white matter was 2.8-4.1. On the basis of these measurements we generated the grey matter SUV, which ranged from 8.1 to 11.3. The

  14. Evaluation of short repetition time, partial flip angle, gradient recalled echo pulse sequences in cervical spine imaging

    International Nuclear Information System (INIS)

    Enzmann, D.; Rubin, J.B.

    1987-01-01

    A short repetition time (TR), partial flip angle, gradient recalled echo pulse sequence (GRASS) was prospectively studied to optimize it for the diagnosis of cervical disk and cord disease in 98 patients. Changes in signal-to-noise ratio (SNR) and contrast were measured as the following parameters were varied: flip angle (3 0 to 18 0 ), TR (22-60 msec), and echo time (TE) (12.5-25 msec). Flip angle was the single most important parameter. For disk disease, cerebrospinal fluid (CSF) SNR peaked at an 8 0 flip angle in the axial view but at a 4 0 flip angle in the sagittal view. In the sagittal view, disk-CSF contrast decreased progressively from a flip angle of 3 0 , while in the axial view it peaked at 10 0 . For cord lesions the findings were similar except that lesion-cord contrast could be increased by lengthening both TR and TE. No one combination of parameters proved greatly superior for either disk disease or cord disease. The selection of parameters required balancing of several factors that often had opposing effects

  15. A Spaceborne Synthetic Aperture Radar Partial Fixed-Point Imaging System Using a Field- Programmable Gate Array-Application-Specific Integrated Circuit Hybrid Heterogeneous Parallel Acceleration Technique.

    Science.gov (United States)

    Yang, Chen; Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue

    2017-06-24

    With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array-application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.

  16. A Spaceborne Synthetic Aperture Radar Partial Fixed-Point Imaging System Using a Field- Programmable Gate Array−Application-Specific Integrated Circuit Hybrid Heterogeneous Parallel Acceleration Technique

    Directory of Open Access Journals (Sweden)

    Chen Yang

    2017-06-01

    Full Text Available With the development of satellite load technology and very large scale integrated (VLSI circuit technology, onboard real-time synthetic aperture radar (SAR imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT, which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array−application-specific integrated circuit (FPGA-ASIC hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.

  17. Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo

    International Nuclear Information System (INIS)

    Zhang, Zhi xiong; Fu, Bu fang; Zhang, De yuan; Zhang, Zhi wei; Cheng, Yan; Sheng, Li yuan; Lai, Chen; Xi, Ting fei

    2013-01-01

    Atrial septal defect (ASD) occlusion devices made of nickel–titanium (NiTi) have a major shortcoming in that they release nickel into the body. We modified NiTi occluders using Arc Ion Plating technology. Nano lamellar titanium–nitrogen (TiN) coatings were formed on the surfaces of the occluders. The safety and efficacy of the modified NiTi occluders were evaluated in animal model. The results showed that 38 out of 39 rams (97%) survived at the end of the experiment. Fibrous capsules formed on the surfaces of the devices. Gradual endothelialization took place through the attachment of endothelial progenitor cells from the blood and the migration of endothelial cells from adjacent endocardium. The neo-endocardium formed more quickly in the coated group than in the uncoated group, as indicated by the evaluation of the six month study group. After TiN coating, there was no significant difference in endothelial cell cycle. TiN coating significantly reduced the release of nickel in both in vivo and in vitro indicating an improved biocompatibility of the nitinol ASD occluders. Superior and modified ASD occluders may provide a good choice for people with nickel allergies after sFDA registration, which is expected in one to two years. - Highlights: ► The nano lamella TiN coating did not change the shape-memory behavior and flexibility of the nitinol occluder. ► Nano lamella TiN coating modifications significantly reduced nickel release from nitinol ASD occluder. ► The new ASD occluder was found to be superior to nitinol ASD occluder with respect to both safety and efficacy

  18. Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhi xiong, E-mail: Top5460@163.com [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Fu, Bu fang, E-mail: fubnicpbp@163.com [National Institutes for Food and Drug Control, Beijing (China); Zhang, De yuan, E-mail: Deyuanzhangcn@yahoo.com.cn [Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen (China); Zhang, Zhi wei, E-mail: Zhzhx65@163.com [Guangdong Cardiovascular Institute, Guangzhou (China); Cheng, Yan, E-mail: chengyan@pku.edu.cn [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing (China); Sheng, Li yuan, E-mail: lysheng@yeah.net [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Lai, Chen, E-mail: laichen1110@163.com [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Xi, Ting fei, E-mail: Xitingfie@pku.edu.cn [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Academy for Advanced Interdisciplinary Studies, Peking University, Beijing (China)

    2013-04-01

    Atrial septal defect (ASD) occlusion devices made of nickel–titanium (NiTi) have a major shortcoming in that they release nickel into the body. We modified NiTi occluders using Arc Ion Plating technology. Nano lamellar titanium–nitrogen (TiN) coatings were formed on the surfaces of the occluders. The safety and efficacy of the modified NiTi occluders were evaluated in animal model. The results showed that 38 out of 39 rams (97%) survived at the end of the experiment. Fibrous capsules formed on the surfaces of the devices. Gradual endothelialization took place through the attachment of endothelial progenitor cells from the blood and the migration of endothelial cells from adjacent endocardium. The neo-endocardium formed more quickly in the coated group than in the uncoated group, as indicated by the evaluation of the six month study group. After TiN coating, there was no significant difference in endothelial cell cycle. TiN coating significantly reduced the release of nickel in both in vivo and in vitro indicating an improved biocompatibility of the nitinol ASD occluders. Superior and modified ASD occluders may provide a good choice for people with nickel allergies after sFDA registration, which is expected in one to two years. - Highlights: ► The nano lamella TiN coating did not change the shape-memory behavior and flexibility of the nitinol occluder. ► Nano lamella TiN coating modifications significantly reduced nickel release from nitinol ASD occluder. ► The new ASD occluder was found to be superior to nitinol ASD occluder with respect to both safety and efficacy.

  19. Weight dependent modulation of motor resonance induced by weight estimation during observation of partially occluded lifting actions

    NARCIS (Netherlands)

    Valchev, Nikola; Zijdewind, Inge; Keysers, Christian; Gazzola, Valeria; Avenanti, Alessio; Maurits, Natasha M.

    Seeing others performing an action induces the observers' motor cortex to "resonate" with the observed action. Transcranial magnetic stimulation (TMS) studies suggest that such motor resonance reflects the encoding of various motor features of the observed action, including the apparent motor

  20. Weight dependent modulation of motor resonance induced by weight estimation during observation of partially occluded lifting actions

    NARCIS (Netherlands)

    Valchev, N.; Zijdewind, I.; Keysers, C.; Gazzola, V.; Avenanti, A.; Maurits, N.M.

    2015-01-01

    Seeing others performing an action induces the observers' motor cortex to "resonate" with the observed action. Transcranial magnetic stimulation (TMS) studies suggest that such motor resonance reflects the encoding of various motor features of the observed action, including the apparent motor

  1. How to manage a case of aymptomatic thoraco-abdominal aortic aneurysm with occluded mesenteric arteries

    Directory of Open Access Journals (Sweden)

    Abhisekh Mohanty

    2015-12-01

    Full Text Available We report a unique case of a 57-year-old male having a suprarenal thoraco-abdominal aortic aneurysm which is extending till the origin of superior mesenteric artery (SMA. The origins of celiac artery and SMA were totally occluded and filled retrogradely through dense collateral vessels arising from the inferior mesenteric artery. Surprisingly, the patient was not having any symptoms related to mesenteric ischemia. We decided to use a conventional aortic aneurysm stent graft to repair it without revascularizing the occluded mesenteric arteries. After 1 month, CT aortogram was repeated which revealed a well-apposed stent graft with no endoleaks. He did not have any clinical signs and symptoms attributable to mesenteric ischemia.

  2. Transcatheter closure of patent ductus arteriosus using the angled duct occluder

    Energy Technology Data Exchange (ETDEWEB)

    Yongwen, Qin; Xianxian, Zhao; Hong, Wu; Xing, Zheng; Jijun, Ding; Jianqiang, Hu [Second Military Medical Univ., Shanghai (China). Changhai Hospital, Dept. of Cardiology

    2004-04-01

    Objective: To assess the immediate efficacy of transcatheter closure of patent ductus arteriosus(PDA) using the angled duct occluder (ADO). Methods: 9 patients (1 male, 8 female) underwent transcatheter closure of PDA using the ADO. The mean PDA diameter at its narrowest segment was (5.8 {+-} 1.9) mm, ranging 3 to 10 mm. A 6 - 9F long sheath was used for the delivery of ADO. Results: The devices were deployed successfully in all patients. Angiographies showed no shunt across the device 15 min after the implantation of ADO. Within 1 week, echocardiography revealed complete closure in all patients. There were no complications. Conclusions: The transcatheter closure of PDA using ADO is an effective and safe procedure. The device matches with the shape of aortic cavity much more precisely than Amplatzer duct occluder. (authors)

  3. Transcatheter closure of patent ductus arteriosus using the angled duct occluder

    International Nuclear Information System (INIS)

    Qin Yongwen; Zhao Xianxian; Wu Hong; Zheng Xing; Ding Jijun; Hu Jianqiang

    2004-01-01

    Objective: To assess the immediate efficacy of transcatheter closure of patent ductus arteriosus(PDA) using the angled duct occluder (ADO). Methods: 9 patients (1 male, 8 female) underwent transcatheter closure of PDA using the ADO. The mean PDA diameter at its narrowest segment was (5.8 ± 1.9) mm, ranging 3 to 10 mm. A 6 - 9F long sheath was used for the delivery of ADO. Results: The devices were deployed successfully in all patients. Angiographies showed no shunt across the device 15 min after the implantation of ADO. Within 1 week, echocardiography revealed complete closure in all patients. There were no complications. Conclusions: The transcatheter closure of PDA using ADO is an effective and safe procedure. The device matches with the shape of aortic cavity much more precisely than Amplatzer duct occluder. (authors)

  4. Partially ordered models

    NARCIS (Netherlands)

    Fernandez, R.; Deveaux, V.

    2010-01-01

    We provide a formal definition and study the basic properties of partially ordered chains (POC). These systems were proposed to model textures in image processing and to represent independence relations between random variables in statistics (in the later case they are known as Bayesian networks).

  5. Partially Hidden Markov Models

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Rissanen, Jorma

    1996-01-01

    Partially Hidden Markov Models (PHMM) are introduced. They differ from the ordinary HMM's in that both the transition probabilities of the hidden states and the output probabilities are conditioned on past observations. As an illustration they are applied to black and white image compression where...

  6. Septic Complication After Balloon-Occluded Retrograde Transvenous Obliteration of Duodenal Variceal Bleeding

    International Nuclear Information System (INIS)

    Akasaka, Thai; Shibata, Toshiya; Isoda, Hiroyoshi; Taura, Kojiro; Arizono, Shigeki; Shimada, Kotaro; Togashi, Kaori

    2010-01-01

    We report a 64-year-old woman with duodenal varices who underwent balloon-occluded retrograde transvenous obliteration (B-RTO) complicated by intraprocedural variceal rupture. The patient developed shivering and a fever higher than 40 o C 3 days after the B-RTO procedure. A blood culture grew Entereobacter cloacoe. This case represents a rare septic complication of B-RTO for duodenal varices.

  7. Transcatheter Retrieval of Embolized Atrial Septal Defect Occluder Device by Waist Capture Technique.

    Science.gov (United States)

    Her, Ae-Young; Lim, Kyung-Hun; Shin, Eun-Seok

    2018-01-27

    This case study describes the successful percutaneous transcatheter retrieval of an embolized Amplatzer occluder device using the "waist capture technique" in a patient with an atrial septal defect. This technique allowed for stability of the Amplatzer device, compression of the atrial discs for easier removal, prevention of further embolization, and minimal injury to vasculature during device retrieval. This novel and effective technique can be used safely for the retrieval of Amplatzer devices in the venous system.

  8. Determination of occluded helium and oxygen in irradiated borosilicate glass samples

    International Nuclear Information System (INIS)

    Ramanjaneyulu, P.S.; Kulkarni, A.S.; Shrivastava, K.C.; Yadav, C.S.; Saxena, M.K.; Tomar, B.S.; Ramakumar, K.L.; Shah, J.G.

    2015-01-01

    Occluded gases in irradiated borosilicate glass were determined at 573, 873 and 1273 K for understanding the radiation damage in glass matrix. Hot vacuum extraction coupled with a quadrupole mass spectrometer technique was employed for the measurements. Relative sensitivity factors of various gases in QMS system were also determined and used for gas composition calculations. At 573 K only helium was found to get released whereas at 873 and 1273 K both helium and oxygen were released with major fraction of oxygen. (author)

  9. The clinical application and effect evaluation of home-made duct occluder in patent ductus arteriosus

    Energy Technology Data Exchange (ETDEWEB)

    Jijun, Shi; Guohong, Zeng; Zhiwei, Zhang; Huishen, Wang; Mingyang, Qian; Yufen, Li [Guangdong Provincial People' s Hospital, Guangdong Provincial Cardiovascular Inst., Guangzhou (China)

    2003-08-01

    Objective: To evaluate the clinical application and effect of transcatheter closure of patent ductus arteriosus (PDA) by using the home-made Xinjian duct occluder. Methods: From June, 2000 to July, 2002, 182 patients (63 male, 119 female) underwent attempted transcatheter closure of patent ductus arteriosus by using the Xinjian duct occluder at a median age of 5.23 years (range 0.3 to 16) and a median weight of 17.09 kg (range 5 to 50). The mean PDA diameter in the narrowest segment was 4.30 mm (range 1.32 to 9.00). The delivery sheath was 6 to 10 F. The median operation time was 73.31 min (range 45 to 135), and the median fluoroscopy time was 7.09 min (range 2.60 to 26.90). Follow-up evaluation was performed with color flow mapping immediately, at 24 h, 1 month, 3 months, 6 months, 1 year, and 2 years after closure, respectively. Results: The Xinjian device was successfully placed in all 182 cases. Angiography showed immediate closure in 109 patients (59.89%), small residual shunt in 30, and trace shunt in 43. At 24 h, color Doppler revealed complete closure in 163 patients. Only 8 patients still had a residual shunt after 1 month. A residual shunt was observed in 4 at 3 months and 6 months, 2 at 1 year, 1 at 2 years. There were no severe complications. Conclusions: Transcatheter closure of PDA using the home-made Xinjian occluder is a safe and effective method. The Xinjian occluder could replace the imported product in the closure of PDA.

  10. The clinical application and effect evaluation of home-made duct occluder in patent ductus arteriosus

    International Nuclear Information System (INIS)

    Shi Jijun; Zeng Guohong; Zhang Zhiwei; Wang Huishen; Qian Mingyang; Li Yufen

    2003-01-01

    Objective: To evaluate the clinical application and effect of transcatheter closure of patent ductus arteriosus (PDA) by using the home-made Xinjian duct occluder. Methods: From June, 2000 to July, 2002, 182 patients (63 male, 119 female) underwent attempted transcatheter closure of patent ductus arteriosus by using the Xinjian duct occluder at a median age of 5.23 years (range 0.3 to 16) and a median weight of 17.09 kg (range 5 to 50). The mean PDA diameter in the narrowest segment was 4.30 mm (range 1.32 to 9.00). The delivery sheath was 6 to 10 F. The median operation time was 73.31 min (range 45 to 135), and the median fluoroscopy time was 7.09 min (range 2.60 to 26.90). Follow-up evaluation was performed with color flow mapping immediately, at 24 h, 1 month, 3 months, 6 months, 1 year, and 2 years after closure, respectively. Results: The Xinjian device was successfully placed in all 182 cases. Angiography showed immediate closure in 109 patients (59.89%), small residual shunt in 30, and trace shunt in 43. At 24 h, color Doppler revealed complete closure in 163 patients. Only 8 patients still had a residual shunt after 1 month. A residual shunt was observed in 4 at 3 months and 6 months, 2 at 1 year, 1 at 2 years. There were no severe complications. Conclusions: Transcatheter closure of PDA using the home-made Xinjian occluder is a safe and effective method. The Xinjian occluder could replace the imported product in the closure of PDA

  11. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder

    OpenAIRE

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-01-01

    OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired,...

  12. Leach resistance properties and release processes for salt-occluded zeolite A

    International Nuclear Information System (INIS)

    Lewis, M.A.; Fischer, D.F.; Laidler, J.J.

    1992-01-01

    The pyrometallurgical processing of spent fuel from the Integral Fast Reactor (IFR) results in a waste of LiCl-KCl-NaCl salt containing approximately 10 wt% fission products, primarily CsCl and SrCl 2 . For disposal, this waste must be immobilized in a form that it is leach resistant. A salt-occluded zeolite has been identified as a potential waste form for the salt. Its leach resistance properties were investigated using powdered samples. The results were that strontium was not released and cesium had a low release, 0.056 g/m 2 for the 56 day leach test. The initial release (within 7 days) of alkali metal cations was rapid and subsequent releases were much smaller. The releases of aluminum and silicon were 0.036 and 0.028 g/m 2 , respectively, and were constant. Neither alkali metal cation hydrolysis nor exchange between cations in the leachate and those in the zeolite was significant. Only sodium release followed t 0.5 kinetics. Selected dissolution of the occluded salt was the primary release process. These results confirm that salt-occluded zeolite has promise as the waste form for IFR pyroprocess salt

  13. Template occluded SBA-15: An effective dissolution enhancer for poorly water-soluble drug

    Energy Technology Data Exchange (ETDEWEB)

    Fu Tingming, E-mail: futingming@gmail.com [College of Pharmacy, Nanjing University of Chinese Medicine, Nanjing 210029 (China); Guo Liwei; Le Kang; Wang Tianyao; Lu Jin [College of Pharmacy, Nanjing University of Chinese Medicine, Nanjing 210029 (China)

    2010-09-15

    The aim of the present work was to improve the dissolution rate of piroxicam by inclusion into template occluded SBA-15. Our strategy involves directly introducing piroxicam into as-prepared SBA-15 occluded with P123 (EO{sub 20}PO{sub 70}EO{sub 20}) by self assembling method in acetonitrile/methylene chloride mixture solution. Ultraviolet spectrometry experiment and thermogravimetric analysis-differential scanning calorimetry (TG-DSC) profiles show that the piroxicam and P123 contents in the inclusion compound are 12 wt% and 28 wt%, respectively. X-ray powder diffraction and DSC analysis reveal that the included piroxicam is arranged in amorphous form. N{sub 2} adsorption-desorption experiment indicates that the piroxicam has been introduced to the mesopores instead of precipitating at the outside of the silica material. The inclusion compound was submitted to in vitro dissolution tests, the results show that the piroxicam dissolve from template occluded inclusion compound more rapidly, than these from the piroxicam crystalline and template removed samples in all tested conditions. Thus a facile method to improve the dissolution rate of poorly water-soluble drug was established, and this discovery opens a new avenue for the utilization of templates used for the synthesis of mesoporous materials.

  14. Total and occluded residual gas content inside the nuclear fuel pellets

    International Nuclear Information System (INIS)

    Moura, Sergio C.; Fernandes, Carlos E.; Oliveira, Justine R.; Machado, Joyce F.; Guglielmo, Luisa M.; Bustillos, Oscar V.

    2009-01-01

    This work describes three techniques available to measure total and occluded residual gases inside the UO 2 nuclear fuel pellets. Hydrogen is the major gas compound inside these pellets, due to sintering fabrication process but Nitrogen is present as well, due to storage atmosphere fuel. The total and occluded residual gas content inside these pellets is a mandatory requirement in a quality control to assure the well function of the pellets inside the nuclear reactor. This work describes the Gas Extractor System coupled with mass spectrometry GES/MS, the Gas Extractor System coupled with gas chromatography GES/GC and the total Hydrogen / Nitrogen H/N analyzer as well. In the GES, occlude gases in the UO 2 pellets is determinate using a high temperature vacuum extraction system, in which the minimum limit of detection is in the range 0.002 cc/g. The qualitative and quantitative determination of the amount of gaseous components employs a mass spectrometry or a gas chromatography technique. The total Hydrogen / Nitrogen analyzer employ a thermal conductivity gas detector linked to a gaseous extractor furnace which has a detection limit is in the range 0.005 cc/g. The specification for the residual gas analyses in the nuclear fuel pellets is 0.03 cc/g, all techniques satisfy the requirement but not the nature of the gases due to reaction with the reactor cladding. The present work details the chemical reaction among Hydrogen / Nitrogen and nuclear reactor cladding. (author)

  15. Template occluded SBA-15: An effective dissolution enhancer for poorly water-soluble drug

    International Nuclear Information System (INIS)

    Fu Tingming; Guo Liwei; Le Kang; Wang Tianyao; Lu Jin

    2010-01-01

    The aim of the present work was to improve the dissolution rate of piroxicam by inclusion into template occluded SBA-15. Our strategy involves directly introducing piroxicam into as-prepared SBA-15 occluded with P123 (EO 20 PO 70 EO 20 ) by self assembling method in acetonitrile/methylene chloride mixture solution. Ultraviolet spectrometry experiment and thermogravimetric analysis-differential scanning calorimetry (TG-DSC) profiles show that the piroxicam and P123 contents in the inclusion compound are 12 wt% and 28 wt%, respectively. X-ray powder diffraction and DSC analysis reveal that the included piroxicam is arranged in amorphous form. N 2 adsorption-desorption experiment indicates that the piroxicam has been introduced to the mesopores instead of precipitating at the outside of the silica material. The inclusion compound was submitted to in vitro dissolution tests, the results show that the piroxicam dissolve from template occluded inclusion compound more rapidly, than these from the piroxicam crystalline and template removed samples in all tested conditions. Thus a facile method to improve the dissolution rate of poorly water-soluble drug was established, and this discovery opens a new avenue for the utilization of templates used for the synthesis of mesoporous materials.

  16. Urgent surgical management for embolized occluder devices in childhood: single center experience

    Directory of Open Access Journals (Sweden)

    Gokaslan Gokhan

    2012-12-01

    Full Text Available Abstract Background In this study, we sought to analyze our experience in urgent surgical management for embolized cardiac septal and ductal occluder devices resulting from trans-catheter closure of atrial septal defect, ventricular septal defect and patent ductus arteriosus in childhood patient group. Methods We retrospectively reviewed 9 patients (aged 2–15 years who underwent urgent surgery due to cardiac septal and ductal occluder embolization between January 2007 and December 2010. Congenital defects were atrial septal defect (n = 6, ventricular septal defect (n = 1, and patent ductus arteriosus (n = 2. Risk factors for device embolization and urgent surgical management techniques for embolized device removal were discussed. Results Removal of embolized devices in all cases and repair of damaged tricuspid valve in 2 patients were performed. Inevitably, all congenital defects were closed or ligated up to the primary defect. Total circulator arrest necessitated in 1 patient with ascending aortic device embolization. All operations were completed successfully and no hospital mortality or morbidity was encountered. Conclusions Although closure of left to right shunting defects by percutaneous occluder devices has a lot of advantages, device embolization is still a major complication. If embolized device retrieval fails with percutaneous intervention attempts, surgical management is the only method to remove embolized devices. In this circumstance, to provide an uneventful perioperative course, urgent management strategies should be well planned.

  17. Indocyanine green videoangiography (ICGV)-guided surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS).

    Science.gov (United States)

    d'Avella, Elena; Volpin, Francesco; Manara, Renzo; Scienza, Renato; Della Puppa, Alessandro

    2013-03-01

    Maximal safe resection is the goal of correct surgical treatment of parasagittal meningiomas, and it is intimately related to the venous anatomy both near and directly involved by the tumor. Indocyanine green videoangiography (ICGV) has already been advocated as an intra-operative resourceful technique in brain tumor surgery for the identification of vessels. The aim of this study was to investigate the role of ICGV in surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS). In this study, we prospectively analyzed clinical, radiological and intra-operative findings of patients affected by parasagittal meningioma occluding the SSS, who underwent ICGV assisted-surgery. Radiological diagnosis of complete SSS occlusion was pre-operatively established in all cases. ICGV was performed before dural opening, before and during tumor resection, at the end of the procedure. Five patients were included in our study. In all cases, ICGV guided dural opening, tumor resection, and venous management. The venous collateral pathway was easily identified and preserved in all cases. Radical resection was achieved in four cases. Surgery was uneventful in all cases. Despite the small number of patients, our study shows that ICG videoangiography could play a crucial role in guiding surgery of parasagittal meningioma occluding the SSS. Further studies are needed to define the role of this technique on functional and oncological outcome of these patients.

  18. Effect of non-Newtonian characteristics of blood on magnetic particle capture in occluded blood vessel

    Science.gov (United States)

    Bose, Sayan; Banerjee, Moloy

    2015-01-01

    Magnetic nanoparticles drug carriers continue to attract considerable interest for drug targeting in the treatment of cancer and other pathological conditions. Magnetic carrier particles with surface-bound drug molecules are injected into the vascular system upstream from the desired target site, and are captured at the target site via a local applied magnetic field. Herein, a numerical investigation of steady magnetic drug targeting (MDT) using functionalized magnetic micro-spheres in partly occluded blood vessel having a 90° bent is presented considering the effects of non-Newtonian characteristics of blood. An Eulerian-Lagrangian technique is adopted to resolve the hemodynamic flow and the motion of the magnetic particles in the flow using ANSYS FLUENT. An implantable infinitely long cylindrical current carrying conductor is used to create the requisite magnetic field. Targeted transport of the magnetic particles in a partly occluded vessel differs distinctly from the same in a regular unblocked vessel. Parametric investigation is conducted and the influence of the insert configuration and its position from the central plane of the artery (zoffset), particle size (dp) and its magnetic property (χ) and the magnitude of current (I) on the "capture efficiency" (CE) is reported. Analysis shows that there exists an optimum regime of operating parameters for which deposition of the drug carrying magnetic particles in a target zone on the partly occluded vessel wall can be maximized. The results provide useful design bases for in vitro set up for the investigation of MDT in stenosed blood vessels.

  19. Aorto-right atrial fistula secondary to rupture of an occluded old saphenous venous graft to right coronary artery.

    Science.gov (United States)

    Balestrini, Carlos Sebastian; Saaibi, José Federico; Ortiz, Santiago Navas

    2014-09-01

    We report a case of an acquired aorta-right atrial fistula, secondary to a ruptured proximal anastomosis of an old saphenous vein graft 12 years after a coronary artery bypass surgery, in a 57 year old patient with multiple cardiovascular risk factors. On admission, he presented with congestive heart failure and on examination a continuous murmur was detected on the right parasternal border. Catheterization showed a fistula from the proximal anastomosis of an occluded right coronary artery saphenous vein graft draining to the right atrium with a large left to right shunt. The fistula was successfully occluded by a percutaneous approach with a Life Tech duct occluder with complete resolution of heart failure. The patient was discharged one week afterwards. After a two-year follow-up, the fistula remained occluded. © 2013 Wiley Periodicals, Inc.

  20. Pan-nitinol occluder and special delivery device for closure of patent ductus arteriosus: a canine-model feasibility study.

    Science.gov (United States)

    Jiang, Hai-bin; Bai, Yuan; Zong, Gang-jun; Han, Lin; Li, Wei-ping; Lu, Yang; Qin, Yong-wen; Zhao, Xian-xian

    2013-01-01

    The aim of this study was to evaluate a new type of occluder for patent ductus arteriosus. Patent ductus arteriosus was established in a canine model by anastomosing a length of autologous jugular vein to the descending aorta and the left pulmonary artery in an end-to-side fashion. Transcatheter closure of each patent ductus arteriosus was performed on 10 dogs, which were then monitored for as long as 6 months with aortography, echocardiography, and histologic evaluation. Transcatheter closure with use of the novel pan-nitinol device was successful in all canine models. Postoperative echocardiography showed that the location and shape of the occluders were normal, without any residual shunting. Further histologic evaluation confirmed that the occluder surface was completely endothelialized 3 months after implantation. Transcatheter patent ductus arteriosus closure with the pan-nitinol occluder can be performed safely and successfully in a canine model and shows good biological compatibility and low mortality rates.

  1. Partial Cancellation

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Partial Cancellation. Full Cancellation is desirable. But complexity requirements are enormous. 4000 tones, 100 Users billions of flops !!! Main Idea: Challenge: To determine which cross-talker to cancel on what “tone” for a given victim. Constraint: Total complexity is ...

  2. The exploration of the closure of patent ductus arteriosus with Amplatzer occluder through single venous approach under ultrasound monitoring

    International Nuclear Information System (INIS)

    Luo Guoxin; He Jianxin; Li Guoying; Gong Zhihua; Wen Yanfei

    2011-01-01

    Objective: To explore the feasibility and effectiveness of transcatheter closure of patent ductus arteriosus (PDA) with Amplatzer occluder by using single venous approach method under ultrasound monitoring. Methods: During the period from May 2003 to April 2010, transcatheter closure of PDA were performed in 123 cases. Of the 123 patients, the procedure was accomplished by using arteriovenous dual approach method in 46 and by using single venous approach method in 77. All the procedures were monitored by ultrasound. The shape, size of PDA and immediate therapeutic results were checked with angiography in arteriovenous dual approach method or with ultrasonography in single venous approach method. The size of Amplatzer occluder was individually selected according to the smallest diameter of PDA. Echocardiography was performed at 3 days, one, 6 and 12 months after the procedure to evaluate the results. Results: Successful device placement with the initially selected occluder was obtained in 118 cases. In 4 cases the procedure was eventually completed after a bigger occluder was employed to replace the initial one, while in one case a smaller occluder had to use to replace the first one. The technical success rate was 100%. Conclusion: The transcatheter closure of PDA with Amplatzer occluder under ultrasound monitoring by single venous approach method is clinically effective and feasible. Being technically simple and time-saving, this single venous approach method is of great value in clinical practice. (authors)

  3. [Accelerated partial breast irradiation with image-guided intensity-modulated radiotherapy following breast-conserving surgery - preliminary results of a phase II clinical study].

    Science.gov (United States)

    Mészáros, Norbert; Major, Tibor; Stelczer, Gábor; Zaka, Zoltán; Mózsa, Emõke; Fodor, János; Polgár, Csaba

    2015-06-01

    The purpose of the study was to implement accelerated partial breast irradiation (APBI) by means of image-guided intensity-modulated radiotherapy (IG-IMRT) following breast-conserving surgery (BCS) for low-risk early invasive breast cancer. Between July 2011 and March 2014, 60 patients with low-risk early invasive (St I-II) breast cancer who underwent BCS were enrolled in our phase II prospective study. Postoperative APBI was given by means of step and shoot IG-IMRT using 4 to 5 fields to a total dose of 36.9 Gy (9×4.1 Gy) using a twice-a-day fractionation. Before each fraction, series of CT images were taken from the region of the target volume using a kV CT on-rail mounted in the treatment room. An image fusion software was used for automatic image registration of the planning and verification CT images. Patient set-up errors were detected in three directions (LAT, LONG, VERT), and inaccuracies were adjusted by automatic movements of the treatment table. Breast cancer related events, acute and late toxicities, and cosmetic results were registered and analysed. At a median follow-up of 24 months (range 12-44) neither locoregional nor distant failure was observed. Grade 1 (G1), G2 erythema, G1 oedema, and G1 and G2 pain occurred in 21 (35%), 2 (3.3%), 23 (38.3%), 6 (10%) and 2 (3.3%) patients, respectively. No G3-4 acute side effects were detected. Among late radiation side effects G1 pigmentation, G1 fibrosis, and G1 fat necrosis occurred in 5 (8.3%), 7 (11.7%), and 2 (3.3%) patients, respectively. No ≥G2 late toxicity was detected. Excellent and good cosmetic outcome was detected in 45 (75%) and 15 (25%) patients. IG-IMRT is a reproducible and feasible technique for the delivery of APBI following conservative surgery for the treatment of low-risk, early-stage invasive breast carcinoma. Preliminary results are promising, early radiation side effects are minimal, and cosmetic results are excellent.

  4. MO-DE-210-06: Development of a Supercompounded 3D Volumetric Ultrasound Image Guidance System for Prone Accelerated Partial Breast Irradiation (APBI)

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, T; Hrycushko, B; Zhao, B; Jiang, S; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: For early-stage breast cancer, accelerated partial breast irradiation (APBI) is a cost-effective breast-conserving treatment. Irradiation in a prone position can mitigate respiratory induced breast movement and achieve maximal sparing of heart and lung tissues. However, accurate dose delivery is challenging due to breast deformation and lumpectomy cavity shrinkage. We propose a 3D volumetric ultrasound (US) image guidance system for accurate prone APBI Methods: The designed system, set beneath the prone breast board, consists of a water container, an US scanner, and a two-layer breast immobilization cup. The outer layer of the breast cup forms the inner wall of water container while the inner layer is attached to patient breast directly to immobilization. The US transducer scans is attached to the outer-layer of breast cup at the dent of water container. Rotational US scans in a transverse plane are achieved by simultaneously rotating water container and transducer, and multiple transverse scanning forms a 3D scan. A supercompounding-technique-based volumetric US reconstruction algorithm is developed for 3D image reconstruction. The performance of the designed system is evaluated with two custom-made gelatin phantoms containing several cylindrical inserts filled in with water (11% reflection coefficient between materials). One phantom is designed for positioning evaluation while the other is for scaling assessment. Results: In the positioning evaluation phantom, the central distances between the inserts are 15, 20, 30 and 40 mm. The distances on reconstructed images differ by −0.19, −0.65, −0.11 and −1.67 mm, respectively. In the scaling evaluation phantom, inserts are 12.7, 19.05, 25.40 and 31.75 mm in diameter. Measured inserts’ sizes on images differed by 0.23, 0.19, −0.1 and 0.22 mm, respectively. Conclusion: The phantom evaluation results show that the developed 3D volumetric US system can accurately localize target position and determine

  5. Partial processing

    International Nuclear Information System (INIS)

    1978-11-01

    This discussion paper considers the possibility of applying to the recycle of plutonium in thermal reactors a particular method of partial processing based on the PUREX process but named CIVEX to emphasise the differences. The CIVEX process is based primarily on the retention of short-lived fission products. The paper suggests: (1) the recycle of fission products with uranium and plutonium in thermal reactor fuel would be technically feasible; (2) it would, however, take ten years or more to develop the CIVEX process to the point where it could be launched on a commercial scale; (3) since the majority of spent fuel to be reprocessed this century will have been in storage for ten years or more, the recycling of short-lived fission products with the U-Pu would not provide an effective means of making refabrication fuel ''inaccessible'' because the radioactivity associated with the fission products would have decayed. There would therefore be no advantage in partial processing

  6. Partial gigantism

    Directory of Open Access Journals (Sweden)

    М.М. Karimova

    2017-05-01

    Full Text Available A girl with partial gigantism (the increased I and II fingers of the left foot is being examined. This condition is a rare and unresolved problem, as the definite reason of its development is not determined. Wait-and-see strategy is recommended, as well as correcting operations after closing of growth zones, and forming of data pool for generalization and development of schemes of drug and radial therapeutic methods.

  7. Influence of the partial volume correction method on (18)F-fluorodeoxyglucose brain kinetic modelling from dynamic PET images reconstructed with resolution model based OSEM.

    Science.gov (United States)

    Bowen, Spencer L; Byars, Larry G; Michel, Christian J; Chonde, Daniel B; Catana, Ciprian

    2013-10-21

    Kinetic parameters estimated from dynamic (18)F-fluorodeoxyglucose ((18)F-FDG) PET acquisitions have been used frequently to assess brain function in humans. Neglecting partial volume correction (PVC) for a dynamic series has been shown to produce significant bias in model estimates. Accurate PVC requires a space-variant model describing the reconstructed image spatial point spread function (PSF) that accounts for resolution limitations, including non-uniformities across the field of view due to the parallax effect. For ordered subsets expectation maximization (OSEM), image resolution convergence is local and influenced significantly by the number of iterations, the count density, and background-to-target ratio. As both count density and background-to-target values for a brain structure can change during a dynamic scan, the local image resolution may also concurrently vary. When PVC is applied post-reconstruction the kinetic parameter estimates may be biased when neglecting the frame-dependent resolution. We explored the influence of the PVC method and implementation on kinetic parameters estimated by fitting (18)F-FDG dynamic data acquired on a dedicated brain PET scanner and reconstructed with and without PSF modelling in the OSEM algorithm. The performance of several PVC algorithms was quantified with a phantom experiment, an anthropomorphic Monte Carlo simulation, and a patient scan. Using the last frame reconstructed image only for regional spread function (RSF) generation, as opposed to computing RSFs for each frame independently, and applying perturbation geometric transfer matrix PVC with PSF based OSEM produced the lowest magnitude bias kinetic parameter estimates in most instances, although at the cost of increased noise compared to the PVC methods utilizing conventional OSEM. Use of the last frame RSFs for PVC with no PSF modelling in the OSEM algorithm produced the lowest bias in cerebral metabolic rate of glucose estimates, although by less than 5% in

  8. Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

    Energy Technology Data Exchange (ETDEWEB)

    Acharya, Sahaja; Fischer-Valuck, Benjamin W.; Mazur, Thomas R.; Curcuru, Austen; Sona, Karl; Kashani, Rojano; Green, Olga; Ochoa, Laura; Mutic, Sasa; Zoberi, Imran; Li, H. Harold; Thomas, Maria A., E-mail: mthomas@radonc.wustl.edu

    2016-11-15

    Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

  9. Magnetic targeting to enhance microbubble delivery in an occluded microarterial bifurcation.

    Science.gov (United States)

    de Saint Victor, M; Carugo, D; Barnsley, L C; Owen, J; Coussios, C-C; Stride, E

    2017-09-05

    Ultrasound and microbubbles have been shown to accelerate the breakdown of blood clots both in vitro and in vivo. Clinical translation of this technology is still limited, however, in part by inefficient microbubble delivery to the thrombus. This study examines the obstacles to delivery posed by fluid dynamic conditions in occluded vasculature and investigates whether magnetic targeting can improve microbubble delivery. A 2D computational fluid dynamic model of a fully occluded Y-shaped microarterial bifurcation was developed to determine: (i) the fluid dynamic field in the vessel with inlet velocities from 1-100 mm s -1 (corresponding to Reynolds numbers 0.25-25); (ii) the transport dynamics of fibrinolytic drugs; and (iii) the flow behavior of microbubbles with diameters in the clinically-relevant range (0.6-5 µm). In vitro experiments were carried out in a custom-built microfluidic device. The flow field was characterized using tracer particles, and fibrinolytic drug transport was assessed using fluorescence microscopy. Lipid-shelled magnetic microbubbles were fluorescently labelled to determine their spatial distribution within the microvascular model. In both the simulations and experiments, the formation of laminar vortices and an abrupt reduction of fluid velocity were observed in the occluded branch of the bifurcation, severely limiting drug transport towards the occlusion. In the absence of a magnetic field, no microbubbles reached the occlusion, remaining trapped in the first vortex, within 350 µm from the bifurcation center. The number of microbubbles trapped within the vortex decreased as the inlet velocity increased, but was independent of microbubble size. Application of a magnetic field (magnetic flux density of 76 mT, magnetic flux density gradient of 10.90 T m -1 at the centre of the bifurcation) enabled delivery of microbubbles to the occlusion and the number of microbubbles delivered increased with bubble size and with decreasing inlet

  10. Clinical assessment of transcatheter closure of patent ductus arteriosus with severe pulmonary hypertention using Amplatzer occluder

    Energy Technology Data Exchange (ETDEWEB)

    Xiumin, Han; Xianyang, Zhu; Yuwei, Zhang; Yan, Jin; Dong' an, Deng; Chanju, Hou; Wei, Quan [Shenyang General Hospital, PLA, Shenyang (China)

    2004-04-01

    Objective: To evaluate the application of transcatheter closure of patent ductus arteriosus (PDA) with severe pulmonary hypertention using the Amplatzer occluder device. Methods: Fifty-one cases of PDA with severe pulmonary hypertention were treated by transcatheter closure with Amplatzer occluder. Patients mean age was 9.4 years (ranging 3 months to 60 years) and the mean weight was (18.7 {+-} 13.8) kg (ranging 5.0 to 65.0 kg). The mean PDA diameter at its narrowest segment was (7.0 {+-} 2.4) (ranging 3.0 to 15.0) mm. The achievement of permanent transcatheter closure was decided according to the change of the pulmonary arterial pressure, aortic pressure and oxygen saturation. Results: The devices were successfully placed in all patients except one failure owing to the resistance of pulmonary hypertention. The systolic pulmonary pressure decreased from (84.7 {+-} 13.5) (range 70 to 137) to mmHg to (46.1 {+-} 14.9) (24 to 109) mmHg, and the mean pulmonary pressure decreased from (65.0 {+-} 11.5) (42 to 97) mmHg to (31.3 {+-} 11.6) (14 to 69) mmHg. Complete angiographic closure was seen 10 minutes after the device deployment in 30 out of 50 patients (60%), while trivial to small leak was present in 20 (40%). Complete echocardiographic closure was demonstrated in 49 out of 50 patients (98%) at 10 min, and 100% at 6-month follow-up in all patients. There were no PDA recanalization and migration of devices after the complete occlusion during following up. Conclusion: Transcatheter closure of patent ductus arteriosus with severe pulmonary hypertention by using the Amplatzer occluder is a safe and effective interventional method with excellent short-term and middle-term results. (authors)

  11. Clinical assessment of transcatheter closure of patent ductus arteriosus with severe pulmonary hypertention using Amplatzer occluder

    International Nuclear Information System (INIS)

    Han Xiumin; Zhu Xianyang; Zhang Yuwei; Jin Yan; Deng Dong'an; Hou Chanju; Quan Wei

    2004-01-01

    Objective: To evaluate the application of transcatheter closure of patent ductus arteriosus (PDA) with severe pulmonary hypertention using the Amplatzer occluder device. Methods: Fifty-one cases of PDA with severe pulmonary hypertention were treated by transcatheter closure with Amplatzer occluder. Patients mean age was 9.4 years (ranging 3 months to 60 years) and the mean weight was (18.7 ± 13.8) kg (ranging 5.0 to 65.0 kg). The mean PDA diameter at its narrowest segment was (7.0 ± 2.4) (ranging 3.0 to 15.0) mm. The achievement of permanent transcatheter closure was decided according to the change of the pulmonary arterial pressure, aortic pressure and oxygen saturation. Results: The devices were successfully placed in all patients except one failure owing to the resistance of pulmonary hypertention. The systolic pulmonary pressure decreased from (84.7 ± 13.5) (range 70 to 137) to mmHg to (46.1 ± 14.9) (24 to 109) mmHg, and the mean pulmonary pressure decreased from (65.0 ± 11.5) (42 to 97) mmHg to (31.3 ± 11.6) (14 to 69) mmHg. Complete angiographic closure was seen 10 minutes after the device deployment in 30 out of 50 patients (60%), while trivial to small leak was present in 20 (40%). Complete echocardiographic closure was demonstrated in 49 out of 50 patients (98%) at 10 min, and 100% at 6-month follow-up in all patients. There were no PDA recanalization and migration of devices after the complete occlusion during following up. Conclusion: Transcatheter closure of patent ductus arteriosus with severe pulmonary hypertention by using the Amplatzer occluder is a safe and effective interventional method with excellent short-term and middle-term results. (authors)

  12. Evaluation on occluded hydrocarbon in deep–ultra deep ancient source rocks and its cracked gas resources

    Directory of Open Access Journals (Sweden)

    Jian Li

    2015-12-01

    Full Text Available Oil-cracked gas, as the main type of high-over mature marine natural gas in China, is mainly derived from occluded hydrocarbon. So it is significant to carry out quantitative study on occluded hydrocarbon. In this paper, the occluded hydrocarbon volume of the main basins in China was calculated depending on their types, abundances and evolution stages by means of the forward method (experimental simulation and the inversion method (geologic profile dissection. And then, occluded hydrocarbon evolution models were established for five types of source rocks (sapropelic, sapropelic prone hybrid, humic prone hybrid, humic and coal. It is shown that the hydrocarbon expulsion efficiency of sapropelic and sapropelic prone hybrid excellent source rocks is lower than 30% at the low-maturity stage, 30%–60% at the principal oil generation stage, and 50%–80% at the high-maturity stage, which are all about 10% higher than that of humic prone hybrid and humic source rocks at the corresponding stages. The resource distribution and cracked gas expulsion of occluded hydrocarbon since the high-maturity stage of marine source rocks in the Sichuan Basin were preliminarily calculated on the basis of the evolution models. The cracked gas expulsion is 230.4 × 1012 m3 at the high evolution stage of occluded hydrocarbon of the Lower Cambrian Qiongzhusi Fm in this basin, and 12.3 × 1012 m3 from the source rocks of Sinian Doushantuo Fm, indicating good potential for natural gas resources. It is indicated that the favorable areas of occluded hydrocarbon cracked gas in the Qiongzhusi Fm source rocks in the Sichuan Basin include Gaoshiti–Moxi, Ziyang and Weiyuan, covering a favorable area of 4.3 × 104 km2.

  13. A novel method of creation of a fenestration in nitinol occluder devices used in closure of hypertensive patent arterial ducts

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2016-01-01

    Full Text Available Test occlusion with a balloon is done to predict operability of large hypertensive patent ductus arteriosus (PDA. If the fall in the pulmonary artery pressures is inadequate, a complete closure is not desired. To create a predictable premeasured fenestration in a nitinol occluder device used for closing hypertensive PDA. A large nitinol occluder device was punctured with an 18G needle to advance a 0.035½ stiff guide wire through the occluder before loading it into the delivery system. The occluder with the guidewire was then deployed across the PDA. A coronary guide catheter was later threaded through the guidewire into the fabric of the device, which was still held by the delivery cable. A coronary stent was deployed across the fenestration in the occluder to keep it patent. An 8-year-old boy with Down syndrome and hypertensive PDA was hemodynamically assessed. Even though there was a fall in the pulmonary vascular resistance index and pressures on test occlusion, the pulmonary artery pressures were labile with fluctuations. A customized fenestration was made in a 16 mm muscular ventricular septal defect occluder (MVSO with a 4.5 mm bare-metal coronary stent. The pulmonary artery pressures remained at half of the aortic pressures after the procedure. This fenestration model precisely and predictably fenestrated a large occluder device used to close a hypertensive large PDA. Long-term patency of these fenestrations has to be assessed on the follow-up, and may be improved through larger fenestrations, systemic anticoagulation and use of covered stents.

  14. Application of Balloon-Occluded Retrograde Transvenous Obliteration to Gastric Varices Complicating Refractory Ascites

    International Nuclear Information System (INIS)

    Fukuda, Tetsuya; Hirota, Shozo; Matsumoto, Shinichi; Sugimoto, Koji; Fujii, Masahiko; Tsurusaki, Masakatsu; Izaki, Kenta; Sugimura, Kazuro

    2004-01-01

    We report two cases of gastric varices complicated by massive ascites that disappeared after balloon-occluded retrograde transvenous obliteration (B-RTO). The first patient had progressive gastric varices that continued to enlarge even after three episodes of esophagogastric variceal bleeding, and the second patient was admitted to our hospital because of the bleeding from gastric varices. After B-RTO procedures in both patients, significant improvement of the ascites, hepatic function reserve, and hypoalbuminemia was observed. Although further experience is needed, our experience points to the likelihood of the amelioration of ascites after B-RTO

  15. Suture fixation of migrated septal occluder device to prevent further migration: a simple surgical technique

    Directory of Open Access Journals (Sweden)

    Mohite Prashant N

    2013-01-01

    Full Text Available Abstract As the use of percutaneous intervention is increasing for the closure of the atrial septal defect, the procedure related complications are also on rise, migration of the device being most common. The migrated devices with failed percutaneous retrieval must be removed surgically under cardiopulmonary bypass. During establishment of cardiopulmonary bypass, the handling of heart may cause further migration of the device into other chambers of heart which leads to difficulty in finding and retrieval of the device. The authors propose a simple and unique technique to prevent further migration of the septal occluder device.

  16. Intraoperative closure of infant multiple muscular ventricular septal defects with Amplatzer occluder

    International Nuclear Information System (INIS)

    Liu Jinfen; Gao Wei; Zhu Zhongqun; Chen Huiwen; Zhang Yuqi

    2005-01-01

    Objective: To report the preliminary experience of intraoperative hybrid therapy for closure of multiple muscular ventricular septal defects (VSD) in a small infant. Methods: After median sternotomy, a AGA Amplatzer occluder was introduced through right ventricular surface to close 2 muscular ventricular septal defects under transesophageal echocardiographic guidance. Results: The infant survived after the treatment without residual shunting, and rehabilitated rapidly. Conclusions: Intraoperative hybrid therapy with combined surgical technique and interventional procedure for closure of multiple muscular VSD in small infant is a safe and effective method. (authors)

  17. Transcatheter closure of membranous ventricular septal defects with home-made nitinol occluder

    Energy Technology Data Exchange (ETDEWEB)

    Yongwen, Qin; Xianxian, Zhao; Xing, Zheng; Jijun, Ding; Jiang, Cao [Second Military Medical Univ., Shanghai (China). Changhai Hospital, Dept. of Cardiology

    2004-04-01

    Objective: To evaluate the feasibility and efficacy of transcatheter perimembranous ventricular septal defects (VSD) occlusion with home-made nitinol occluder. Methods: Transcatheter closure was attempted in 196 patients with perimembranous VSD. The diameter of VSD measured by echocardiography was 3 to 15 mm, mean (4.94 {+-} 2.23) mm. The angiographic diameter of the VSD was 3 to 6 mm, mean (3.92 {+-} 1.44) mm. A 7-10 F delivery sheath was advanced across the perimembranous VSD over a wire from femoral vein to deploy the occluder with the guidance of echocardiography and fluoroscopy. The device diameter selected was from 4 to 20 mm, mean (6.68 {+-} 2.76) mm. Left ventriculography and transthoracic echocardiography were repeated to assess the closure of the defects 15 min after the procedure. Continuous electrocardiogram monitoring lasted for 5 days. The echocardiography and electrocardiogram examination were scheduled for 1, 6 and 12 months of follow-up. Results: The occluders were successfully deployed in 191 patients. There were five procedural failures, two with device-related aortic insufficiency, and three of inability to pass through VSD. After deployment of the devices, there were no residual shunt in 180 of 191 patients, 11 patients with a trivial residual shunt that disappeared in 8 patients after one month of follow up. 3 patients developed mild tricuspid insufficiency. 12 developed transient complete right bundle branch block, and 5 transient complete left bundle branch block, and 2 transient complete atrioventricular block. There were repetitive nonparoxysmal ventricular tachycardia in 4 patients 1 week after the procedure. One patient had a detached device embolized into the left pulmonary artery but with a successful catheter retrieval by snare and transcatheter closure. The devices were similarly applied to patients with VSD associated with patent ductus arteriosus, and 4 patients with VSD complicated by atrial septal defects. The fluoroscopy time

  18. Transcatheter closure of membranous ventricular septal defects with home-made nitinol occluder

    International Nuclear Information System (INIS)

    Qin Yongwen; Zhao Xianxian; Zheng Xing; Ding Jijun; Cao Jiang

    2004-01-01

    Objective: To evaluate the feasibility and efficacy of transcatheter perimembranous ventricular septal defects (VSD) occlusion with home-made nitinol occluder. Methods: Transcatheter closure was attempted in 196 patients with perimembranous VSD. The diameter of VSD measured by echocardiography was 3 to 15 mm, mean (4.94 ± 2.23) mm. The angiographic diameter of the VSD was 3 to 6 mm, mean (3.92 ± 1.44) mm. A 7-10 F delivery sheath was advanced across the perimembranous VSD over a wire from femoral vein to deploy the occluder with the guidance of echocardiography and fluoroscopy. The device diameter selected was from 4 to 20 mm, mean (6.68 ± 2.76) mm. Left ventriculography and transthoracic echocardiography were repeated to assess the closure of the defects 15 min after the procedure. Continuous electrocardiogram monitoring lasted for 5 days. The echocardiography and electrocardiogram examination were scheduled for 1, 6 and 12 months of follow-up. Results: The occluders were successfully deployed in 191 patients. There were five procedural failures, two with device-related aortic insufficiency, and three of inability to pass through VSD. After deployment of the devices, there were no residual shunt in 180 of 191 patients, 11 patients with a trivial residual shunt that disappeared in 8 patients after one month of follow up. 3 patients developed mild tricuspid insufficiency. 12 developed transient complete right bundle branch block, and 5 transient complete left bundle branch block, and 2 transient complete atrioventricular block. There were repetitive nonparoxysmal ventricular tachycardia in 4 patients 1 week after the procedure. One patient had a detached device embolized into the left pulmonary artery but with a successful catheter retrieval by snare and transcatheter closure. The devices were similarly applied to patients with VSD associated with patent ductus arteriosus, and 4 patients with VSD complicated by atrial septal defects. The fluoroscopy time for the

  19. A partial differential equation-based general framework adapted to Rayleigh's, Rician's and Gaussian's distributed noise for restoration and enhancement of magnetic resonance image.

    Science.gov (United States)

    Yadav, Ram Bharos; Srivastava, Subodh; Srivastava, Rajeev

    2016-01-01

    The proposed framework is obtained by casting the noise removal problem into a variational framework. This framework automatically identifies the various types of noise present in the magnetic resonance image and filters them by choosing an appropriate filter. This filter includes two terms: the first term is a data likelihood term and the second term is a prior function. The first term is obtained by minimizing the negative log likelihood of the corresponding probability density functions: Gaussian or Rayleigh or Rician. Further, due to the ill-posedness of the likelihood term, a prior function is needed. This paper examines three partial differential equation based priors which include total variation based prior, anisotropic diffusion based prior, and a complex diffusion (CD) based prior. A regularization parameter is used to balance the trade-off between data fidelity term and prior. The finite difference scheme is used for discretization of the proposed method. The performance analysis and comparative study of the proposed method with other standard methods is presented for brain web dataset at varying noise levels in terms of peak signal-to-noise ratio, mean square error, structure similarity index map, and correlation parameter. From the simulation results, it is observed that the proposed framework with CD based prior is performing better in comparison to other priors in consideration.

  20. Continuous partial status cause of hyperintensity in cerebral cortex in magnetic resonance imaging; Estatus parcial continuo, causa de hiperintensidad de la corteza cerebral en la resonancia nuclear magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Lopez L, Ingeborg; Gonzalez L, Daniela [Departamento de Ciencias Neurologicas Oriente. Facultad de Medicina, Universidad de Chile, Santiago (Chile); Quezada R, Patricio [Servicio de Neurologia, Hospital Salvador, Santiago (Chile); Cartier R, Luis [Departamento de Ciencias Neurologicas Oriente. Facultad de Medicina, Universidad de Chile, Santiago (Chile)

    2012-07-01

    Magnetic Resonance Imaging has demonstrated functional changes of the cerebral cortex in relation to status epilepticus, which can eventually localize the origin of the crisis. The purpose of this presentation is relevant to this condition and pretends to highlight the action of incidental situations that can modify it. We present a 29 year old woman with a neurosurgical intervention for a neuroblastoma irradiated fifteen years ago, which incidentally starts a continuous partial status epilepticus, expressed by clonies of the face and left limbs associated with functional impotence, resistant to oral therapy. Faced with the suspicion of recurrence of the tumor, a brain MRI is performed, showing hyperintensity of all neural areas the right hemisphere, with no evidence of tumor recurrence. Once submitted the status epilepticus, the hyperintensity disappeared in the hemisphere. This extensive reaction of the neural structures might be related to a permanent effect of radiation, which may have caused a mismatch functional glia, of the blood-brain barrier and interneural network.

  1. Early experience with the Occlutech PLD occluder for mitral paravalvar leak closure through a hybrid transapical approach.

    Science.gov (United States)

    Bedair, Radwa; Morgan, Gareth J; Bapat, Vinayak; Kapetanakis, Stamatis; Goreczny, Sebastian; Simpson, John; Qureshi, Shakeel A

    2016-12-10

    We sought to evaluate the feasibility and efficacy of hybrid transapical closure of paravalvar mitral leaks using a new Occlutech PLD occluder in patients with heart failure and/or haemolytic anaemia. Retrospective analysis of clinical and procedural data was undertaken for patients who had attempted closure of paravalvar mitral leaks via a hybrid transapical approach with the Occlutech PLD occluder. Eight patients (four males, median age 69 years) underwent closure of 10 mitral paravalvar leaks using eight Occlutech PLD occluders and two AMPLATZER Vascular Plugs (AVP II). Successful deployment, with significant reduction of the paravalvar leak was achieved in seven patients with short procedure (median 131 min) and fluoroscopy times (median 22 min). One patient had mechanical interference with prosthetic valve function, requiring surgery. Another patient with a high EuroSCORE (48.8%) died of multi-organ failure two days after the procedure. Clinical improvement in either heart failure or haemolysis was seen in all discharged patients. In our series of patients with challenging anatomy, the Occlutech PLD occluders performed well when implanted via a hybrid transapical approach. Further work is needed to assess this methodology fully for a wider population and to assess other deployment approaches for this promising new occluder.

  2. Transcatheter coil occluder for closure of ventricular septal defect (a report of 4 cases)

    International Nuclear Information System (INIS)

    Gao Wei; Zhou Aiqing; Yu Zhiqing; Li Fen; Zhong Yumin; Zhang Yuqi; Huang Meirong; Sun Kun

    2005-01-01

    Objective: To explore the indication, methodology and complication of transcatheter coil closure of ventricular septal defect (VSD) in children. Methods: Transcatheter closure of perimembranous VSD with coils was performed in 4 cases from 2003 to 2005. The Duct-Occlude (pfm) and detachable coil (Cook) were chosen for embolization depending on the results of the left ventricular angiogram. The coil size was generally about 1-4 mm larger than the diameter of VSD. Follow up was carried out with echocardiography, ultrasound and clinical examination. Results: The defect diameters of the four cases were 2.0 mm, 2.7 mm, 2.5 mm and 1.5 mm respectively. The Duct-Occlude were successfully implanted in 3 cases of perimembranous VSD with the same type coil (OD[mm]7-3-6, windings 5-3-4) for each. One detachable coil (Cook) (5 x 5) was implanted in the remaining case. All cases had trivial residual shunt immediately after implantation which disappeared 24 hours later. Follow-up for 2 months to one year showed no coil displacement and secondary bacterial arteritis. No tricuspid and aortic regurgitation, no emboli, no endocarditis, and no arrhythmia were found. Conclusions: Coil closure of some small VSD with membranate part pseudo-ventricular aneurysm has good efficacy with the advantages of simple operation, less metal content and mini-invasion also applicable for infants. (authors)

  3. Quantitative analysis of occluded gases in uranium dioxide pellets by the mass spectrometry technique

    International Nuclear Information System (INIS)

    Vega Bustillos, J.O.W.; Rodrigues, C.; Iyer, S.S.

    1981-05-01

    A quantitative analysis of different components of occluded gases except water in uranium dioxide pellets is attempted here. A high temperature vacuum extration system is employed for the liberation and the determination of total volume of the occluded gases. A mass spectrometric technique is employed for the qualitative and quantitative analysis of these gases. The UO 2 pellets are placed in a graphite crucible and are subjected to varing temperatures (1000 0 C - 1700 0 C). The liberated gases are dehydrated and transferred to a measuring unit consisting essentially of a Toepler pump and a McLeod gauge. In this system the total volume of the gases liberated at N. T. P. is determined with a sensitivity of 0.002 cm 3 /g of UO 2 . An aliquot of the liberated gas is introduced into a quadrupole mass spectrometer (VGA-100 Varian Corp.) for the determination of the different components of the gas. On the basis of the analysis suggestions are made for the possible sources of these gas components. (Author) [pt

  4. Densification of salt-occluded zeolite a powders to a leach-resistant monolith

    International Nuclear Information System (INIS)

    Lewis, M.A.; Fischer, D.F.; Murhpy, C.D.

    1993-01-01

    Pyrochemical processing of spent fuel from the Integral Fast Reactor (IFR) yields a salt waste of LiCl-KCl that contains approximately 6 wt% fission products, primarily as CsCl and SrCl 2 . Past work has shown that zeolite A will preferentially sorb cesium and strontium and will encapsulate the salt waste in a leach-resistant, radiation-resistant aluminosilicate matrix. However, a method is sill needed to convert the salt-occluded zeolite powders into a form suitable for geologic disposal. We are thus investigating a method that forms bonded zeolite by hot pressing a mixture of glass frit and salt-occluded zeolite powders at 990 K (717 degree C) and 28 MPa. The leach resistance of the bonded zeolite was measured in static leach tests run for 28 days in 363 K (90 degree C) deionized water. Normalized release rates of all elements in the bonded zeolite were low, 2 d. Thus, the bonded zeolite may be a suitable waste form for IFR salt waste

  5. Efficacy and safety of balloon-occluded retrograde transvenous obliteration with sodium tetradecyl sulfate liquid sclerotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Park, Sang Woo; Kwon, So Young; Cheo, Won Hyeok; Cheon, Young Koog; Shim, Chan Sup; Lee, Tae Yoon; Kim, Jeong Han [Digestive Disease Center, Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    To evaluate the efficacy and safety of balloon-occluded retrograde transvenous obliteration (BRTO) with sodium tetradecyl sulfate (STS) liquid sclerotherapy of gastric varices. Between February 2012 and August 2014, STS liquid sclerotherapy was performed in 17 consecutive patients (male:female = 8:9; mean age 58.6 years, range 44-86 years) with gastric varices. Retrograde venography was performed after occlusion of the gastrorenal shunt using a balloon catheter and embolization of collateral draining veins using coils or gelfoam pledgets, to evaluate the anatomy of the gastric varices. We prepared 2% liquid STS by mixing 3% STS and contrast media in a ratio of 2:1. A 2% STS solution was injected into the gastric varices until minimal filling of the afferent portal vein branch was observed (mean 19.9 mL, range 6-33 mL). Patients were followed up using computed tomography (CT) or endoscopy. Technical success was achieved in 16 of 17 patients (94.1%). The procedure failed in one patient because the shunt could not be occluded due to the large diameter of gastrorenal shunt. Complete obliteration of gastric varices was observed in 15 of 16 patients (93.8%) with follow-up CT or endoscopy. There was no rebleeding after the procedure. There was no procedure-related mortality. BRTO using STS liquid can be a safe and useful treatment option in patients with gastric varices.

  6. Sympathetic responses during saline infusion into the veins of an occluded limb.

    Science.gov (United States)

    Cui, Jian; McQuillan, Patrick; Moradkhan, Raman; Pagana, Charles; Sinoway, Lawrence I

    2009-07-15

    Animal studies have shown that the increased intravenous pressure stimulates the group III and IV muscle afferent fibres, and in turn induce cardiovascular responses. However, this pathway of autonomic regulation has not been examined in humans. The aim of this study was to examine the hypothesis that infusion of saline into the venous circulation of an arterially occluded vascular bed evokes sympathetic activation in healthy individuals. Blood pressure, heart rate, and muscle sympathetic nerve activity (MSNA) responses were assessed in 19 young healthy subjects during local infusion of 40 ml saline into a forearm vein in the circulatory arrested condition. From baseline (11.8 +/- 1.2 bursts min(-1)), MSNA increased significantly during the saline infusion (22.5 +/- 2.6 bursts min(-1), P Blood pressure also increased significantly during the saline infusion. Three control trials were performed during separate visits. The results from the control trial show that the observed MSNA and blood pressure responses were not due to muscle ischaemia. The present data show that saline infusion into the venous circulation of an arterially occluded vascular bed induces sympathetic activation and an increase in blood pressure. We speculate that the infusion under such conditions stimulates the afferent endings near the vessels, and evokes the sympathetic activation.

  7. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    Science.gov (United States)

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  8. Magnetic resonance imaging (MRI) findings among children with fetal alcohol syndrome (FAS), partial fetal alcohol syndrome (pFAS) and alcohol related neurodevelopmental disorders (ARND).

    Science.gov (United States)

    Anna Dyląg, Katarzyna; Sikora-Sporek, Aleksanda; Bańdo, Bożena; Boroń-Zyss, Joanna; Drożdż, Dorota; Dumnicka, Paulina; Przybyszewska, Katarzyna; Sporek, Mateusz; Walocha, Jerzy W; Wojciechowski, Wadim; Urbanik, Andrzej

    The aim of the study was to analyze the findings in MRI (magnetic resonance imaging) of the brain amongst children diagnosed with fetal alcohol syndrome (FAS), partial fetal alcohol syndrome (pFAS) or alcohol related neurodevelopmental disorders (ARND). The issue has been studied in several researches previously but the experts agree that there is still few data on the MRI results in the group of younger children. MRI results of 121 patients with either FAS or pFAS or ARND diagnosed with Canadian criteria were analyzed regarding the presence of abnormalities. The group consisted of 71 patients diagnosed with FAS, 33 diagnosed with pFAS and 17 diagnosed with ARND. The mean age of the patients was 8.03 years (standard deviation 4.07). In the total group of FASD patients 61.98% of the patients’ MRI results were abnormal. The most common abnormality in MRI of the patients were demyelination plaques (incidence 23.1%) and corpus callosum narrowing (20.7%) as well as ventricular asymmetry (18.8%).The demyelination plaques and corpus callosum narrowing were more frequent among children ≤4 years old (41.7% vs 18.6%; p=0.016 and 50.0% vs.13.4%; ppFAS and ARND. Both age ≤4 years and FAS diagnosis were independent predictors for multiple anomalies in multiple logistic regression. In structural brain MRI of younger children, multiple anomalies were found more frequently than among older children. Demyelination plaques and corpus callosum narrowing were more common in younger FASD patients than in older ones.

  9. An improved optimization algorithm of the three-compartment model with spillover and partial volume corrections for dynamic FDG PET images of small animal hearts in vivo

    Science.gov (United States)

    Li, Yinlin; Kundu, Bijoy K.

    2018-03-01

    The three-compartment model with spillover (SP) and partial volume (PV) corrections has been widely used for noninvasive kinetic parameter studies of dynamic 2-[18F] fluoro-2deoxy-D-glucose (FDG) positron emission tomography images of small animal hearts in vivo. However, the approach still suffers from estimation uncertainty or slow convergence caused by the commonly used optimization algorithms. The aim of this study was to develop an improved optimization algorithm with better estimation performance. Femoral artery blood samples, image-derived input functions from heart ventricles and myocardial time-activity curves (TACs) were derived from data on 16 C57BL/6 mice obtained from the UCLA Mouse Quantitation Program. Parametric equations of the average myocardium and the blood pool TACs with SP and PV corrections in a three-compartment tracer kinetic model were formulated. A hybrid method integrating artificial immune-system and interior-reflective Newton methods were developed to solve the equations. Two penalty functions and one late time-point tail vein blood sample were used to constrain the objective function. The estimation accuracy of the method was validated by comparing results with experimental values using the errors in the areas under curves (AUCs) of the model corrected input function (MCIF) and the 18F-FDG influx constant K i . Moreover, the elapsed time was used to measure the convergence speed. The overall AUC error of MCIF for the 16 mice averaged  -1.4  ±  8.2%, with correlation coefficients of 0.9706. Similar results can be seen in the overall K i error percentage, which was 0.4  ±  5.8% with a correlation coefficient of 0.9912. The t-test P value for both showed no significant difference. The mean and standard deviation of the MCIF AUC and K i percentage errors have lower values compared to the previously published methods. The computation time of the hybrid method is also several times lower than using just a stochastic

  10. [Percutaneous closure of ductus arteriosus and muscular ventricular defect with amplatzer occluder in a patient with severe pulmonary hypertension].

    Science.gov (United States)

    García-Montes, José Antonio; Zabal Cerdeira, Carlos; Calderón-Colmenero, Juan; Espínola, Nilda; Fernández de la Reguera, Guillermo; Buendía Hernández, Alfonso

    2005-01-01

    Surgical treatment of multiple muscular ventricular septal defects with associated lesions and severe pulmonary hypertension has a high morbility and mortality. Closure of these defects by the Amplatzer muscular VSD occluder is an alternative to surgery, avoiding the need of cardiopulmonary bypass. We present the case of a 38 year-old woman with signs of heart failure in NYHA functional class IV, with two muscular ventricular septal defects, patent ductus arteriosus and severe pulmonary hypertension, that were treated with three Amplatzer muscular VSD occluders, with significant reduction of pulmonary pressure and functional class improvement.

  11. Image inpainting based on stacked autoencoders

    International Nuclear Information System (INIS)

    Shcherbakov, O; Batishcheva, V

    2014-01-01

    Recently we have proposed the algorithm for the problem of image inpaiting (filling in occluded or damaged parts of images). This algorithm was based on the criterion spectrum entropy and showed promising results despite of using hand-crafted representation of images. In this paper, we present a method for solving image inpaiting task based on learning some image representation. Some results are shown to illustrate quality of image reconstruction.

  12. Evaluation of thallium-201 imaging in nontransmural ischemia and infarction

    International Nuclear Information System (INIS)

    Haidar, B.; Oldewurtel, H.A.; Moschos, C.B.; Lee, W.K.; Regan, T.J.

    1981-01-01

    To assess the validity of thallium-201 myocardial imaging in the diagnosis of nontransmural ischemia and infarction, the proximal left anterior descending coronary artery was partially occluded for 60 minutes with a balloon-tip catheter in intact anesthetized dogs in a basal state or during atrial pacing. In vivo scintigrams of myocardium were compared with those obtained in the isolated heart and in the incised ventricle spread flat. None of the animals with partial occlusion with or without pacing demonstrated abnormal scintiscans in vivo. Removal of background by isolating the heart increased positive images to 30%; positive images were associated with an isotope count ratio between ischemic and normal muscle of less than 0.67. Removal of superimposed nonischemic muscle in the heart enface increased image detection after pacing to 11 of 15. Since animals with subendocardial scar failed to demonstrate a cold area in vivo, unfavorable geometry as well as extent and degree of ischemia appear to be important. Thus, thallium radioactivity in superimposed and adjacent myocardium, as well as background, may limit the detection of nontransmural ischemia and scar

  13. In vivo production of recombinant proteins using occluded recombinant AcMNPV-derived baculovirus vectors.

    Science.gov (United States)

    Guijarro-Pardo, Eva; Gómez-Sebastián, Silvia; Escribano, José M

    2017-12-01

    Trichoplusia ni insect larvae infected with vectors derived from the Autographa californica multiple nucleopolyhedrovirus (AcMNPV), are an excellent alternative to insect cells cultured in conventional bioreactors to produce recombinant proteins because productivity and cost-efficiency reasons. However, there is still a lot of work to do to reduce the manual procedures commonly required in this production platform that limit its scalability. To increase the scalability of this platform technology, a current bottleneck to be circumvented in the future is the need of injection for the inoculation of larvae with polyhedrin negative baculovirus vectors (Polh-) because of the lack of oral infectivity of these viruses, which are commonly used for production in insect cell cultures. In this work we have developed a straightforward alternative to obtain orally infective vectors derived from AcMNPV and expressing recombinant proteins that can be administered to the insect larvae (Trichoplusia ni) by feeding, formulated in the insect diet. The approach developed was based on the use of a recombinant polyhedrin protein expressed by a recombinant vector (Polh+), able to co-occlude any recombinant Polh- baculovirus vector expressing a recombinant protein. A second alternative was developed by the generation of a dual vector co-expressing the recombinant polyhedrin protein and the foreign gene of interest to obtain the occluded viruses. Additionally, by the incorporation of a reporter gene into the helper Polh+ vector, it was possible the follow-up visualization of the co-occluded viruses infection in insect larvae and will help to homogenize infection conditions. By using these methodologies, the production of recombinant proteins in per os infected larvae, without manual infection procedures, was very similar in yield to that obtained by manual injection of recombinant Polh- AcMNPV-based vectors expressing the same proteins. However, further analyses will be required for a

  14. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder.

    Science.gov (United States)

    Bilici, Meki; Demir, Fikri; Akın, Alper; Türe, Mehmet; Balık, Hasan; Kuyumcu, Mahir

    2017-12-01

    The aim of this study was to evaluate the feasibility, efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with the Occlutech duct occluder (ODO) in children. We reviewed the clinical records of 71 patients who underwent percutaneous closure of PDA with an ODO between September 2014 and August 2016. The Occlutech duct occluder was applied to 71 patients during the study period (September 2014-August 2016), and the results were analyzed in this study. Forty-two of the patients were female and 29 male. The median age was 20.5 months (range, 6-194 months) and median weight was 16 kg (range, 6-68 kg). The PDA was classified as type A in 54 patients (76.1%), type E in 14 (19.7%), type C in 2 (2.8%) and type B in 1 (1.4%) based on the Krichenko classification. A standard ODO device was used for the transcatheter closure procedure in 66 patients and the long-shank ODO device in 5. In the echocardiographic measurement of PDA, the median smallest diameter was 2.7 mm (range, 1.5-7.0 mm), and in the angiographic measurement, the median smallest diameter was 2.5 mm (range, 1.5-6.5 mm). All 71 patients underwent successful PDA closure with the ODO. Angiography following the procedure showed complete closure in 47 patients (66.2%), mild residual shunt in 13 patients (18.3%) and a trivial shunt in 11 patients (15.5%). Color flow Doppler echocardiogpaphy at 24 h post-implantation showed that complete closure was achieved in 65 patients (91.5%), and 6 patients (8.5%) had mild residual shunt. All patients (100%) had complete closure at 30 days of follow-up. The results of this study showed that the Occlutech PDA occluder device is safe and effective in the closure of PDA. As the pulmonary artery side of the device is wider than the aortic side, protrusion toward the aortic side and embolization are prevented, but there is residual shunt in the early period, although this residual shunt disappeared after a few months.

  15. Evaluation of the partial volume effect in the activity quantification in PET/CT images; Avaliacao do efeito de volume parcial na quantificacao de atividade em imagens de PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Krempser, Alexandre R., E-mail: krempser@peb.ufrj.br [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Instituto Alberto Luiz Coimbra. Programa de Engenharia Biomedica; Oliveira, Silvia M. Velasques de [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Almeida, Sergio A. de [Hospital Samaritano, Rio de Janeiro, RJ (Brazil). Centro de Imagens PET/CT

    2012-08-15

    The aim of this work was to evaluate the influence of partial volume effect (PVE) in the quantification of activity in images of a PET-CT scanner and its ability to identify lesions. Recovery coefficients were calculated using a phantom containing 12 cylinders with diameters between 4 and 30 mm and a National Electrical Manufactures Association scattering phantom, both fillable with known concentrations of {sup 18}F. The images were acquired for acquisition time of 3 and 5 minutes, and cylinder to background ratio of n=8:1 and n=4:1. The recovery coefficients were calculated between 0.01 and 0.91 depending on the diameter. Significant variations were not found in function of image acquisition parameters. Errors in the activity quantification above 70% were found for cylinders with diameters smaller than 10 mm. The cylinders with diameters smaller than 8 mm were not identified in the images. The phantoms were adequate for PVE evaluation in the PET/CT images. The PVE had the greatest impact on the cylinders with diameters of 6 and 4 mm. It's necessary to use partial volume correction techniques in the images in order to increase the quantitative accuracy of the studied equipment. (author)

  16. Anatomic partial nephrectomy: technique evolution.

    Science.gov (United States)

    Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S

    2015-03-01

    Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.

  17. Progressive Occlusion of Small Saccular Aneurysms Incompletely Occluded After Stent-Assisted Coil Embolization : Analysis of Related Factors and Long-Term Outcomes.

    Science.gov (United States)

    Lim, Jeong Wook; Lee, Jeongjun; Cho, Young Dae

    2017-08-08

    Incompletely occluded aneurysms after coil embolization are subject to recanalization but occasionally progress to a totally occluded state. Deployed stents may actually promote thrombosis of coiled aneurysms. We evaluated outcomes of small aneurysms (medium was evident after stent-assisted coiling, assessing factors implicated in subsequent progressive occlusion. Between September 2012 and June 2016, a total of 463 intracranial aneurysms were treated by stent-assisted coil embolization. Of these, 132 small saccular aneurysms displayed saccular filling with contrast medium in the immediate aftermath of coiling. Progressive thrombosis was defined as complete aneurysmal occlusion at the 6‑month follow-up point. Rates of progressive occlusion and factors predisposing to this were analyzed via binary logistic regression. In 101 (76.5%) of the 132 intracranial aneurysms, complete occlusion was observed in follow-up imaging studies at 6 months. Binary logistic regression analysis indicated that progressive occlusion was linked to smaller neck diameter (odds ratio [OR] = 1.533; p = 0.003), hyperlipidemia (OR = 3.329; p = 0.036) and stent type (p = 0.031). The LVIS stent is especially susceptible to progressive thrombosis, more so than Neuroform (OR = 0.098; p = 0.008) or Enterprise (OR = 0.317; p = 0.098) stents. In 57 instances of progressive thrombosis, followed for ≥12 months (mean 25.0 ± 10.7 months), 56 (98.2%) were stable, with minor recanalization noted once (1.8%) and no major recanalization. Aneurysms associated with smaller diameter necks, hyperlipidemic states and LVIS stent deployment may be inclined to possible thrombosis, if occlusion immediately after stent-assisted coil embolization is incomplete. In such instances, excellent long-term durability is anticipated.

  18. Use of the Amplatzer ASD Occluder for Closing a Persistent Left Vertical Vein

    International Nuclear Information System (INIS)

    Zanchetta, Mario; Zennaro, Marco; Zecchel, Roberto; Mancuso, Daniela; Pedon, Luigi

    2009-01-01

    We report the case of a very large anomalous connection of the veins draining the upper lobe of the left lung to both the left-sided vertical vein and the left atrium, associated with mild rheumatic mitral valve stenosis, in which the atrial septum was intact and the remaining venous system, including the coronary sinus, was otherwise normal (a variant of Lutembacher's syndrome). In order to abolish the left-to-right shunting, a transcatheter approach to close this venous structure was successfully attempted using an Amplatzer ASD Occluder device. The technical aspects and the alternative options of performing a procedure with a device for a purpose outside the scope of its approved label are discussed.

  19. Transcatheter closure of patent ductus arteriosus using the AMPLATZER™ duct occluder II (ADO II).

    Science.gov (United States)

    Gruenstein, Daniel H; Ebeid, Makram; Radtke, Wolfgang; Moore, Phillip; Holzer, Ralf; Justino, Henri

    2017-05-01

    The study purpose is to evaluate the safety and efficacy of the ADO II device for closure of patent ductus arteriosus (PDA) in children. Transcatheter treatment of PDA has been evolving for 40+ years and is the treatment of choice. The AMPLATZER™ Duct Occluder (ADO) device was developed for larger diameter ducts and is not ideal in all PDAs. ADO II was developed for small to moderate-sized ducts. This is a single-arm, multicenter study evaluating safety and efficacy of the ADO II device. Patients closure in 98% of successful implantations. In this prospective study, the ADO II was safe and effective for closure of small to moderate PDAs. Implantation is simple and the ability for retrograde aortic delivery reduces procedure-related radiation exposure. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  20. Percutaneous closure of a large aortic paravalvular leak using two duct occluder devices

    Directory of Open Access Journals (Sweden)

    Navaneetha Sasikumar

    2013-05-01

    Full Text Available A 21-year-old male presented with severe aortic paravalvular leak. He had undergone three cardiac surgeries and also had chronic kidney disease. It was decided for a trans-catheter closure owing to the risks of a fourth surgery and co-morbidity. The device was sized based on angiogram, balloon sizing and two dimensional transesophageal echo. There was significant residual leak after deployment of first device. Hence the defect was re-crossed and two duct occluder devices were positioned across the leak from two arterial access. After confirming position and satisfactory reduction in paravalvular leak, the devices were released in tandem. There was near abolition of leak. The patient is asymptomatic at three months follow up. Larger paravalvular leaks are better addressed with two devices of smaller size rather than a single large device. Technical considerations while deploying multiple devices are discussed.

  1. Carotid endarterectomy in cervical block anesthesia in patients with occluded contralateral internal carotid artery

    Directory of Open Access Journals (Sweden)

    Ilijevski Nenad

    2006-01-01

    Full Text Available Introduction: The goal of modern carotid surgery is relief of symptoms, stroke prevention, improvement in quality of life, prevention of vascular dementia, and prolongation of lifetime. OBJECTIVE: The objective of this paper was to compare the outcome of carotid endarterectomy in cervical block vs. general anesthesia in patients with occluded contralateral internal carotid artery (ICA. METHOD: One hundred patients (76 male, 24 female, mean age 60.81 years with occluded contralateral ICA were operated from 1997-2000. Neurological symptomatology, deficiency and stroke incidence were preoperatively analyzed in two groups. Duplex-scanning, angiograms and CT-scan confirmed the diagnosis. Risk factors analysis included hypertension, diabetes, lipid metabolism disorders, smoking and history of CAD, CABG and PAOD. Morbidity and mortality were used to compare the outcome of surgery in two groups. RESULTS There was no difference of age, gender and symptomatology between the groups. Paresis, TIA and dysphasia were most frequent. 70%-90% of ICA stenosis was seen in the majority of patients. Hypertension and smoking were dominant risk factors in these two groups. Eversion carotid end arterectomy was the most frequent technique used. In three cases out of nine that were operated under cervical block, the neurological symptoms developed just after clamping, so the intra-luminal shunt was placed. Postoperative morbidity was 12% and mortality was 8%. Conclusion: There was no difference of preoperative parameters, surgical technique and outcome in these two groups. Without other intraoperative monitoring, cervical block anesthesia might be an option in patients with the occlusion of the contralateral ICA. However, prospective studies involving more patients are needed.

  2. An Infectious Pseudoaneurysm Caused by Ventricular Septal Defect Occluder in Patent Ductus Arteriosus Closure in a Two-Year-Old Child.

    Science.gov (United States)

    Li, Dingyang; Qiu, Qiu; Jin, Jing; Zhang, Changdong; Wang, Lijun; Zhang, Gangcheng

    2017-12-12

    We present a case of an infectious pseudoaneurysm after patent ductus arteriosus (PDA) closure with a ventricular septal defect (VSD) occluder in a two-year-old child. The aneurysm grew rapidly but was successfully removed in time and the patient survived. To our knowledge, this is the first report of an infectious pseudoaneurysm caused by VSD occluder in PDA closure.

  3. Percutaneous transluminal angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child after liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yussim, Ethan; Belenky, Alexander; Atar, Eli [Department of Diagnostic Radiology, Rabin Medical Center, Vascular and Interventional Radiology Unit, Petah Tikva (Israel); Shapiro, Rivka [Schneider Children' s Medical Center, Institute of Pediatric Gastroenterology and Nutrition, Petah Tikva (Israel); Mor, Eytan [Rabin Medical Center, Department of Organ Transplantation, Petah Tikva (Israel)

    2005-07-01

    Percutaneous transluminal angioplasty is increasingly used in children. We present a case of successful balloon angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child who underwent liver transplantation because of biliary atresia. Percutaneous reopening of the shunt is a relatively safe procedure that may spare patients of surgical intervention. (orig.)

  4. Percutaneous transluminal angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child after liver transplantation

    International Nuclear Information System (INIS)

    Yussim, Ethan; Belenky, Alexander; Atar, Eli; Shapiro, Rivka; Mor, Eytan

    2005-01-01

    Percutaneous transluminal angioplasty is increasingly used in children. We present a case of successful balloon angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child who underwent liver transplantation because of biliary atresia. Percutaneous reopening of the shunt is a relatively safe procedure that may spare patients of surgical intervention. (orig.)

  5. Study on transcatheter ASD occlusion using modified atrial septal defect occluder with no stainless steel screw in canine model

    International Nuclear Information System (INIS)

    Xuan Bin; Qin Yongwen; Hu Jianqiang; Wu Hong

    2006-01-01

    Objective: To evaluate the safety, biocompatibility and efficacy of transcatheter closure of atrial septal defect (ASD) with no stainless-steel-screw occluder in canine model. Methods: The device was constructed from superelastic Nitinol wires tightly woven into two flat disks and sewed with polyester fibers inside, with a pliable loop on the right-atrial-disk of the device, connecting to the delivery cable. ASD was created by transcatheter puncture and balloon dilatation and then closed by occluder under fluoroscopy in the catheterization laboratory. the location and the influence of the implanted device on function of tricuspid valve and mitral valve were evaluated by echocardiography. At 1, 2, 3 and 6 months after the operation, the animals were killed and autopsy was conducted. Results: Eight dogs with puncture-produced ASD underwent ASD closing procedure successfully. the occluder showed no influence on the function of MV and AV demonstrated by echocardiogram. The two disks of the implanted device were covered with a smooth intact neogenesis layer in all dogs. Endocardial cells fully covered the surface of the two disk without inflammating reaction 3 months later. There was no evidence of corrosion on the surface of the nitinol wire removed from the dog after 6 months. Light microscopic examination of the liver, kidney, lung and spleen showed no evidence of embolization and inflammation. Conclusion: Transcatheter ASD occlusion with new-type occluder is safe, feasible, effective and good biocompatibility with a good prospective clinical application. (authors)

  6. A unified computational model of the development of object unity, object permanence, and occluded object trajectory perception.

    Science.gov (United States)

    Franz, A; Triesch, J

    2010-12-01

    The perception of the unity of objects, their permanence when out of sight, and the ability to perceive continuous object trajectories even during occlusion belong to the first and most important capacities that infants have to acquire. Despite much research a unified model of the development of these abilities is still missing. Here we make an attempt to provide such a unified model. We present a recurrent artificial neural network that learns to predict the motion of stimuli occluding each other and that develops representations of occluded object parts. It represents completely occluded, moving objects for several time steps and successfully predicts their reappearance after occlusion. This framework allows us to account for a broad range of experimental data. Specifically, the model explains how the perception of object unity develops, the role of the width of the occluders, and it also accounts for differences between data for moving and stationary stimuli. We demonstrate that these abilities can be acquired by learning to predict the sensory input. The model makes specific predictions and provides a unifying framework that has the potential to be extended to other visual event categories. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Comparison of axial lengths in occludable angle and angle-closure glaucoma-The Bhaktapur Glaucoma Study

    NARCIS (Netherlands)

    Thapa, S.S.; Paudyal, I.; Khanal, S.; Paudel, N.; van Rens, G.H.M.B.

    2011-01-01

    Purpose. To compare the anterior chamber depth (ACD) and axial length of eyes in a population-based sample among normal, occludable angle, and primary angle-closure glaucoma (PACG) groups. Methods. Totally, 3979 subjects from a population-based glaucoma prevalence study underwent complete ocular

  8. Balloon occluded retrograde transvenous obliteration of bleeding stomal varices using sodium tetradecyl sulfate foam: A case report

    International Nuclear Information System (INIS)

    Kim, Ji Chang; Yang, Po Sang; Lee, Yeon Soo; Kim, Hyun Jeong; Park, Gun

    2015-01-01

    A small varix is an uncommon complication with a high mortality rate occurring secondary to portal hypertension in patients with a stoma. We describe a case of recurrent stomal varix bleeding successfully managed by balloon occluded retrograde transvenous obliteration using sodium tetradecyl sulfate foam.

  9. Survey research report by the hydrogen occluding alloy utilization development committee; Suiso kyuzo gokin riyo kaihatsu iinkai chosa kenkyu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1985-03-01

    This report summarizes the FY 1984 survey research results, issued by the hydrogen occluding alloy utilization development committee. The basic property subcommittee is responsible for collecting published data related to the basic properties of metal halides as much as possible, and pigeonholing them to have the data which can contribute to development of the new alloys for basic researches and engineering applications of hydrogen occluding alloys. The subcommittee members have collected these data. The common theme subcommittee has planned to collect the P-C-T diagrams of the hydrogen occluding alloys and new alloys as much as possible, for the designs, development, production and system designs of the hydrogen occluding alloys. The P-C-T diagrams have been collected for a total of 340 types of alloys, which fall into the broad categories of Mg-based, TiFe-based, TiMn-based, other Ti-based, rare-earth-based, Zr-based, Ca-based and others. The analytical methods have been also investigated while collecting P-C-T diagrams. (NEDO)

  10. Balloon occluded retrograde transvenous obliteration of bleeding stomal varices using sodium tetradecyl sulfate foam: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Chang; Yang, Po Sang; Lee, Yeon Soo; Kim, Hyun Jeong; Park, Gun [Dept. of Radiology, The Catholic University of Korea College of Medicine, Daejeon St. Mary' s Hospital, Daejeon (Korea, Republic of)

    2015-05-15

    A small varix is an uncommon complication with a high mortality rate occurring secondary to portal hypertension in patients with a stoma. We describe a case of recurrent stomal varix bleeding successfully managed by balloon occluded retrograde transvenous obliteration using sodium tetradecyl sulfate foam.

  11. Generalized Partial Volume

    DEFF Research Database (Denmark)

    Darkner, Sune; Sporring, Jon

    2011-01-01

    Mutual Information (MI) and normalized mutual information (NMI) are popular choices as similarity measure for multimodal image registration. Presently, one of two approaches is often used for estimating these measures: The Parzen Window (PW) and the Generalized Partial Volume (GPV). Their theoret...... of view as well as w.r.t. computational complexity. Finally, we present algorithms for both approaches for NMI which is comparable in speed to Sum of Squared Differences (SSD), and we illustrate the differences between PW and GPV on a number of registration examples....

  12. Sensitivity and specificity of bell-hammer tear as an indirect sign of partial anterior cruciate ligament rupture on magnetic resonance imaging.

    Science.gov (United States)

    Lefevre, N; Naouri, J F; Bohu, Y; Klouche, S; Herman, S

    2014-05-01

    The main purpose of this study was to evaluate the usefulness of the bell-hammer sign in the diagnosis of partial tears of the anterior cruciate ligament (ACL) of the knee on MRI. A retrospective study was performed including all patients who underwent ACL reconstruction for partial or complete tears from 2008 to 2009. The diagnosis of partial or complete ACL tears was based on the appearance of the ligament bundles and the signal quality on MRI. On arthroscopy, which is considered the gold standard, each bundle was classified as normal, partially or completely torn depending on the extent of the rupture and the quality of the remaining fibres. The study included 312 patients, 83 women and 229 men (mean age 33.3 ± 19.6 years). A diagnosis of a tear was made in all patients on preoperative MRI. Arthroscopy did not show any normal ACL, 247/312 (79.2 %) complete tears and 65/312 (20.8%) partial tears, 50/65 (76.9%) on the anteromedial bundle (AM) and 15/65 (23.1%) the posterolateral bundle. The bell-hammer sign was found on MRI in 13/312 patients (4.5%). It involved 9/65 (13.8%) partial tears, all in the AM bundle, and 4/247 (1.6%) complete tears, significantly more frequent in cases of partial rupture (p hammer sign (sensitivity CI 95% = 23.1 ± 10%, specificity CI 95% = 95.9 ± 2.5%) and with the bell-hammer sign in 23/65 cases (sensitivity CI 95% = 35.4 ± 11%, specificity CI 95% = 93.9 ± 3%). The association of the bell-hammer sign with conventional radiological diagnostic criteria has improved diagnosis performance of MRI for partial tears but not significantly (ns). The most important interest of the bell-hammer sign in the day-to-day clinical work is to suggest partial tears on MRI. It aids making a diagnosis, but its absence does not exclude partial ACL rupture. Diagnostic study, Level II.

  13. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results

    Science.gov (United States)

    Sinha, Santosh Kumar; Razi, Mahmadula; Pandey, Rama Niwas; Kumar, Prakash; Krishna, Vinay; Jha, Mukesh Jitendra; Mishra, Vikas; Asif, Mohammad; Abdali, Nasar; Tewari, Pradyot; Thakur, Ramesh; Pandey, Umeshwar; Varma, Chandra Mohan

    2017-01-01

    Objective: To evaluate the feasibility, safety, and efficacy of a novel Cocoon Duct Occluder device for the transcatheter closure (TCC) of large patent ductus arteriosus (PDA). Methods: In this prospective, non-randomized study, consecutive patients with large PDA (narrowest diameter: ≥3.5/4.0 mm in symptomatic/asymptomatic patients, respectively), who underwent TCC with Cocoon Duct Occluder at our institute between November, 2012 and June, 2016 were examined. TCC was performed using the standard technique, and devices were antegradely delivered via 6–10F delivery sheaths. Device embolization, residual shunt, hemolysis, left pulmonary artery (LPA) stenosis, procedural and fluoroscopy time, and mortality were assessed. Patients were followed-up by transthoracic echocardiography with color Doppler imaging at 24 h (D1), 1 month (D30), and 6 months (D180) after implantation. Results: A total of 57 patients (age: 11.7±2.8 years; weight: 22.3±3.5 kg) were enrolled. The mean narrowest diameter was 7.4±0.7 mm. The PDA closure was successfully performed in each patient. Fluoroscopy and procedural time was 6.7±3.2 min and 23.9±2.7 min, respectively. Postprocedural angiography revealed that 49 (85.9%) patients had immediate and complete closure, whereas 8 (14.1%) had residual shunt. Color Doppler imaging at D1 revealed complete closure in 52 (91.3%) patients. At D30, complete closure was reported in all patients and was maintained at D180. Hemolysis, embolization, obstruction of LPA or descending aorta, and death were not reported till D180. Conclusion: TCC using Cocoon Duct Occluder is feasible, safe, and effective in the management of patients with large PDA, with excellent results on short- and medium-term follow-up. PMID:29145233

  14. DNA unwinding by ring-shaped T4 helicase gp41 is hindered by tension on the occluded strand.

    Science.gov (United States)

    Ribeck, Noah; Saleh, Omar A

    2013-01-01

    The replicative helicase for bacteriophage T4 is gp41, which is a ring-shaped hexameric motor protein that achieves unwinding of dsDNA by translocating along one strand of ssDNA while forcing the opposite strand to the outside of the ring. While much study has been dedicated to the mechanism of binding and translocation along the ssDNA strand encircled by ring-shaped helicases, relatively little is known about the nature of the interaction with the opposite, 'occluded' strand. Here, we investigate the interplay between the bacteriophage T4 helicase gp41 and the ss/dsDNA fork by measuring, at the single-molecule level, DNA unwinding events on stretched DNA tethers in multiple geometries. We find that gp41 activity is significantly dependent on the geometry and tension of the occluded strand, suggesting an interaction between gp41 and the occluded strand that stimulates the helicase. However, the geometry dependence of gp41 activity is the opposite of that found previously for the E. coli hexameric helicase DnaB. Namely, tension applied between the occluded strand and dsDNA stem inhibits unwinding activity by gp41, while tension pulling apart the two ssDNA tails does not hinder its activity. This implies a distinct variation in helicase-occluded strand interactions among superfamily IV helicases, and we propose a speculative model for this interaction that is consistent with both the data presented here on gp41 and the data that had been previously reported for DnaB.

  15. Transcatheter closure of secundum atrial septal defect with cardio SEAL septal occluder. A preliminary result of clinical application

    International Nuclear Information System (INIS)

    Zhang Gejun; Dai Ruping; Liu Yanling; Jiang Shiliang; Zeng Zheng; Huang Lianjun; Xie Ruolan

    2001-01-01

    Objective: To evaluate the efficiency and preliminary results of transcatheter closure of secundum atrial septal defect (ASD) with CardioSEAL septal occluder. Methods: There were 12 patients in this study. Trans-esophageal echocardiography (TEE) before the interventions confirmed the ASDs with a mean diameter of *13.14 +- 3.48) mm (ranging from 8 to 20 mm). There were 11 isolated ASDs and 1 multi-defects ASD in the group. Each ASD was occluded with CardioSEAL septal occluder through the percutaneous procedure. The closure procedure was guided by fluoroscopy and trans-esophageal echocardiography. The TEE was done immediately after the procedure to find whether there was residual shunt. Trans-thoracic-echocardiography (TTE), ECG, and X-ray examination were done 24 hours, 1 month, 3 months, and 1 year after the procedures as follow-up to evaluate the efficiency. Results: The placements of the occluders were successful in 11 cases. There were no mortality and no emergent surgery during the procedures. TEE confirmed that there were trivial and small residual shunts in 3 cases immediately after the procedures. TTE confirmed small residual shunts in 2 cases 24 hour after the procedures, and in 1 case 1 month, 3 month, and 1 year after the procedures. Conclusion: Transcatheter closure of secundum ASD with CardioSEAL septal occluder was an efficient nonsurgical method. It could be the method of choice in treating the ASDs with special anatomic variations. It had a high successful rate of device placement and satisfied preliminary results, but the long-term follow-up was needed

  16. Implementation of image-guided intensity-modulated accelerated partial breast irradiation. Three-year results of a phase II clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Meszaros, Norbert; Major, Tibor; Stelczer, Gabor; Zaka, Zoltan; Takacsi-Nagy, Zoltan; Fodor, Janos; Polgar, Csaba [National Institute of Oncology, Center of Radiotherapy, Budapest (Hungary); Mozsa, Emoke [National Institute of Oncology, Center of Radiotherapy, Budapest (Hungary); Landesklinikum, Department of Radiooncology and Radiotherapy, Wiener Neustadt (Austria); Pukancsik, David [National Institute of Oncology, Department of Breast and Sarcoma Surgery, Budapest (Hungary)

    2017-01-15

    To report 3-year results of accelerated partial breast irradiation (APBI) using image-guided intensity-modulated radiotherapy (IG-IMRT) following breast conserving surgery (BCS) for low-risk early invasive breast cancer. Between July 2011 and March 2014, 60 patients with low-risk early invasive breast cancer underwent BCS and were enrolled in this phase II prospective study. The total dose was 36.9 Gy (9 fractions of 4.1 Gy, two fractions/day). Patient setup errors were detected in LAT, LONG and VERT directions. Local tumour control, survival results, early and late side effects and cosmetic outcome were assessed. At a median follow-up of 39 months, all patients were alive and neither locoregional nor distant failure occurred. One contralateral breast cancer and two new primary malignancies outside the breast were observed. No grade (G) 3-4 acute toxicity was detected. G1 and G2 erythema occurred in 21 (35%) and 2 (3.3%) patients, respectively; while G1 oedema was observed in 23 (38.8%) cases. G1 and G2 pain was reported by 6 (10%) and 2 (3.3%) patients, respectively. Among the late radiation side effects, G1 pigmentation or telangiectasia, G1 fibrosis and G1 asymptomatic fat necrosis occurred in 10 (16.7%), 7 (11.7%) and 3 (5%) patients, respectively. No ≥ G2 late toxicity was detected. Cosmetic outcome was excellent in 43 (71.7%) and good in 17 (28.3%) patients. IG-IMRT is a reproducible and feasible technique for delivery of external beam APBI following BCS for treatment of low-risk, early-stage invasive breast carcinoma. In order to avoid toxicity, image guidance performed before each radiation fraction is necessary to minimize the PTV. Three-year results are promising, early and late radiation side-effects are minimal, and cosmetic results are excellent to good. (orig.) [German] Evaluierung der 3-Jahres-Ergebnisse der Teilbrustbestrahlung (APBI) mittels bildgefuehrter intensitaetsmodulierter Strahlentherapie (IG-IMRT) nach brusterhaltender Operation (BCS

  17. Comparison of Coil Embolization and Sclerotherapy of Collateral Veins during Balloon Occluded Retrograde Transvenous Obliteration: Its Long Term Effect for Gastric Varix Treatment

    International Nuclear Information System (INIS)

    An, Eun Jung; Kim, Young Hwan; Kim, Seee Hyung

    2011-01-01

    We compared the long term effect gastric varix treatment between coil embolization and sclerotherapy of collateral veins during balloon occluded retrograde transvenous obliteration (BRTO). Between February 2004 and November 2008 48 patients with gastric varix bleeding successfully treated with BRTO 23 underwent embolization of collateral veins during BRTO were enrolled in this study. In patients, collateral veins were embolized with the use of microcoil (group 1). Agent (5% ethanolamine oleate + lipiodol) was used in the remaining 7 patients (Group 2). Recurrence and rebleeding of gastric varix were evaluated by endoscopy or CT. Gastric varix recurred in 4 patients (17.4%) and rebleeding occurred in 2 (8.7%). Recurrence (57.1%, p 0.001) and rebleeding (28.6%, p = 0.029) of gastric occurred in group 2. CT finding within 6 months in partial or complete thrombosis without lipiodol uptake in gastric varix, gastric varix recurred on follow up CT. Coil embolization of collateral veins during BRTO may promote complete obliteration of gastric varix, provide lower recurrence and rebleeding rates of gastric sclerosing agent on long term follow-up.

  18. Dynamic CT myocardial perfusion imaging: detection of ischemia in a porcine model with FFR verification

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.

  19. Improved curvature-based inpainting applied to fine art: recovering van Gogh's partially hidden brush strokes

    Science.gov (United States)

    Kuang, Yubin; Stork, David G.; Kahl, Fredrik

    2011-03-01

    Underdrawings and pentimenti-typically revealed through x-ray imaging and infrared reflectography-comprise important evidence about the intermediate states of an artwork and thus the working methods of its creator.1 To this end, Shahram, Stork and Donoho introduced the De-pict algorithm, which recovers layers of brush strokes in paintings with open brush work where several layers are partially visible, such as in van Gogh's Self portrait with a grey felt hat.2 While that preliminary work served as a proof of concept that computer image analytic methods could recover some occluded brush strokes, the work needed further refinement before it could be a tool for art scholars. Our current work makes several steps to improve that algorithm. Specifically, we refine the inpainting step through the inclusion of curvature-based constraints, in which a mathematical curvature penalty biases the reconstruction toward matching the artist's smooth hand motion. We refine and test our methods using "ground truth" image data: passages of four layers of brush strokes in which the intermediate layers were recorded photographically. At each successive top layer (currently identified by the user), we used k-means clustering combined with graph cuts to obtain chromatically and spatially coherent segmentation of brush strokes. We then reconstructed strokes at the deeper layer with our new curvature-based inpainting algorithm based on chromatic level lines. Our methods are clearly superior to previous versions of the De-pict algorithm on van Gogh's works giving smoother, natural strokes that more closely match the shapes of unoccluded strokes. Our improved method might be applied to the classic drip paintings of Jackson Pollock, where the drip work is more open and the physics of splashing paint ensures that the curvature more uniform than in the brush strokes of van Gogh.

  20. Feasibility of MR Imaging/MR Spectroscopy-Planned Focal Partial Salvage Permanent Prostate Implant (PPI) for Localized Recurrence After Initial PPI for Prostate Cancer

    International Nuclear Information System (INIS)

    Hsu, Charles C.; Hsu, Howard; Pickett, Barby; Crehange, Gilles; Hsu, I-Chow Joe; Dea, Ryan; Weinberg, Vivian; Gottschalk, Alexander R.; Kurhanewicz, John; Shinohara, Katsuto; Roach, Mack

    2013-01-01

    Purpose: To assess the feasibility of magnetic resonance imaging (MRI)-planned partial salvage permanent prostate implant (psPPI) among patients with biopsy-proven local recurrence after initial PPI without evidence of distant disease. Methods and Materials: From 2003-2009, 15 patients underwent MRI/magnetic resonance spectroscopy (MRS) planning for salvage brachytherapy (psPPI, I-125 [n=14; 144 Gy]; Pd-103 [n=1; 125 Gy]) without hormone therapy. Full dose was prescribed to areas of recurrence and underdosage, without entire prostate implantation. Limiting urethral and rectal toxicity was prioritized. Follow-up was from salvage date to prostate-specific antigen (PSA) concentration failure (Phoenix criteria = nadir + 2.0; ASTRO = 3 consecutive rises), recurrence, distant metastases, or last follow-up PSA level. Progression-free survival (PFS) was defined as no PSA failure or biopsy-proven recurrence without all-cause mortality. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Results: At salvage, median age was 68 years, and PSA concentration was 3.5 ng/mL (range, 0.9-5.6 ng/mL). Abnormal MRI/MRS findings were evident in 40% of patients. Biopsy-proven recurrences consisted of a single focus (80%) or 2 foci (20%). At recurrence, Gleason score was 6 (67%) or ≥7 (27%). Median interval between initial and salvage implantation was 69 months (range, 28-132 months). psPPI planning characteristics limited doses to the rectum (mean V100 = 0.5% [0.07 cc]) and urethra (V100 = 12% [0.3 cc]). At median follow-up (23.3 months; range, 8-88 months), treatment failure (n=2) resulted only in localized recurrence; both patients underwent second psPPI with follow-up PSA tests at 12 and 26 months, resulting in 0.6 and 0.7 ng/mL, respectively. American Society for Radiation Oncology PFS rates at 1, 2, and 3 years were 86.7%, 78.4%, and 62.7%, respectively, with 5 patients for whom treatment failed (n=3 with negative transrectal ultrasound

  1. Feasibility of MR Imaging/MR Spectroscopy-Planned Focal Partial Salvage Permanent Prostate Implant (PPI) for Localized Recurrence After Initial PPI for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Charles C., E-mail: hsucc@radonc.ucsf.edu [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Hsu, Howard [Department of Radiation Oncology, New York University, New York, New York (United States); Pickett, Barby [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Crehange, Gilles [Department of Radiation Oncology, Dijon University, Dijon (France); Hsu, I-Chow Joe; Dea, Ryan [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Weinberg, Vivian [Biostatistics and Computational Biology Core, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Gottschalk, Alexander R. [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Kurhanewicz, John [Department of Radiology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Shinohara, Katsuto [Department of Urology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Roach, Mack [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States)

    2013-02-01

    Purpose: To assess the feasibility of magnetic resonance imaging (MRI)-planned partial salvage permanent prostate implant (psPPI) among patients with biopsy-proven local recurrence after initial PPI without evidence of distant disease. Methods and Materials: From 2003-2009, 15 patients underwent MRI/magnetic resonance spectroscopy (MRS) planning for salvage brachytherapy (psPPI, I-125 [n=14; 144 Gy]; Pd-103 [n=1; 125 Gy]) without hormone therapy. Full dose was prescribed to areas of recurrence and underdosage, without entire prostate implantation. Limiting urethral and rectal toxicity was prioritized. Follow-up was from salvage date to prostate-specific antigen (PSA) concentration failure (Phoenix criteria = nadir + 2.0; ASTRO = 3 consecutive rises), recurrence, distant metastases, or last follow-up PSA level. Progression-free survival (PFS) was defined as no PSA failure or biopsy-proven recurrence without all-cause mortality. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Results: At salvage, median age was 68 years, and PSA concentration was 3.5 ng/mL (range, 0.9-5.6 ng/mL). Abnormal MRI/MRS findings were evident in 40% of patients. Biopsy-proven recurrences consisted of a single focus (80%) or 2 foci (20%). At recurrence, Gleason score was 6 (67%) or {>=}7 (27%). Median interval between initial and salvage implantation was 69 months (range, 28-132 months). psPPI planning characteristics limited doses to the rectum (mean V100 = 0.5% [0.07 cc]) and urethra (V100 = 12% [0.3 cc]). At median follow-up (23.3 months; range, 8-88 months), treatment failure (n=2) resulted only in localized recurrence; both patients underwent second psPPI with follow-up PSA tests at 12 and 26 months, resulting in 0.6 and 0.7 ng/mL, respectively. American Society for Radiation Oncology PFS rates at 1, 2, and 3 years were 86.7%, 78.4%, and 62.7%, respectively, with 5 patients for whom treatment failed (n=3 with negative transrectal ultrasound

  2. Coronal View Ultrasound Imaging of Movement in Different Segments of the Tongue during Paced Recital: Findings from Four Normal Speakers and a Speaker with Partial Glossectomy

    Science.gov (United States)

    Bressmann, Tim; Flowers, Heather; Wong, Willy; Irish, Jonathan C.

    2010-01-01

    The goal of this study was to quantitatively describe aspects of coronal tongue movement in different anatomical regions of the tongue. Four normal speakers and a speaker with partial glossectomy read four repetitions of a metronome-paced poem. Their tongue movement was recorded in four coronal planes using two-dimensional B-mode ultrasound…

  3. Partial volume effect (PVE) on the arterial input function (AIF) in T1-weighted perfusion imaging and limitations of the multiplicative rescaling approach

    DEFF Research Database (Denmark)

    Hansen, Adam Espe; Pedersen, Henrik; Rostrup, Egill

    2009-01-01

    The partial volume effect (PVE) on the arterial input function (AIF) remains a major obstacle to absolute quantification of cerebral blood flow (CBF) using MRI. This study evaluates the validity and performance of a commonly used multiplicative rescaling of the AIF to correct for the PVE. In a gr...

  4. Adaptive Partially Hidden Markov Models

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Rasmussen, Tage

    1996-01-01

    Partially Hidden Markov Models (PHMM) have recently been introduced. The transition and emission probabilities are conditioned on the past. In this report, the PHMM is extended with a multiple token version. The different versions of the PHMM are applied to bi-level image coding....

  5. Gonioscopy findings and prevalence of occludable angles in a Burmese population: the Meiktila Eye Study.

    Science.gov (United States)

    Casson, R J; Newland, H S; Muecke, J; McGovern, S; Abraham, L M; Shein, W K; Selva, D; Aung, T

    2007-07-01

    To determine the prevalence of preglaucomatous angle-closure disease in central Myanmar. A population-based survey of inhabitants >or=40 years in the Meiktila District was carried out; 2481 subjects were identified, 2076 participated and 2060 underwent gonioscopy of at least one eye. Eyes with angles traditionally described as "occludable" were recorded as primary angle-closure suspects (PACS); eyes with PACS and peripheral anterior synechiae (PAS), or an increased intraocular pressure but without primary angle-closure glaucoma, were recorded as primary angle closure (PAC). The prevalence of PACS in at least one eye was 5.7% (95% CI 4.72 to 6.62); prevalence increased with age and was more common in women (p<0.001). The prevalence of PAC in at least one eye was 1.50% (95% CI 1.47 to 1.53). All participants with PAS had at least 90 degrees of closure (range 90-360 degrees). The prevalence of preglaucomatous angle-closure disease (PACS and PAC) in this population was 5.7% and 1.5%, respectively. PACS was more common in women, and its prevalence increased with age.

  6. Complications Following Balloon-Occluded Arterial Infusion Chemotherapy for Pelvic Malignancies

    International Nuclear Information System (INIS)

    Sugimoto, Koji; Hirota, Shozo; Imanaka, Kazufumi; Kawabe, Tetsuya; Nakayama, Yoshiharu; Takeuchi, Yasuhito

    1999-01-01

    Purpose: To evaluate the incidence and causes of complications associated with balloon-occluded arterial infusion chemotherapy (BOAI) for pelvic malignancies. Methods: In 34 courses of BOAI in 22 patients with pelvic malignancies, we analyzed the incidence of complications as well as the effect of the dose of the anticancer drugs, the infusion site, and the number of BOAI administrations on these complications. Complications were divided into two categories: cystitis-like symptoms and neurological complications such as pain, numbness, and paresthesia of the lower extremities and the hip. Results: Eleven patients (50%) suffered from complications, seven (31.8%) from neurological complications and four (18.2%) from cystitis-like symptoms. The complications appeared in 14 courses (42.4%) of BOAI, neurological complications in 10 (30.3%) and cystitis-like symptoms in four (12.1%). A high dose of anti-cancer drugs and infusion from the anterior division tended to induce neurological complications more frequently; however, the cystitis-like symptoms were not related to any factors. Conclusion: Our results indicate that a smaller dose of anti-cancer drugs should be infused from the bilateral internal iliac arteries for safer pelvic BOAI

  7. Controlling the hydration of the skin though the application of occluding barrier creams.

    Science.gov (United States)

    Sparr, Emma; Millecamps, Danielle; Isoir, Muriel; Burnier, Véronique; Larsson, Åsa; Cabane, Bernard

    2013-03-06

    The skin is a barrier membrane that separates environments with profoundly different water contents. The barrier properties are assured by the outer layer of the skin, the stratum corneum (SC), which controls the transepidermal water loss. The SC acts as a responding membrane, since its hydration and permeability vary with the boundary condition, which is the activity of water at the outer surface of the skin. We show how this boundary condition can be changed by the application of a barrier cream that makes a film with a high resistance to the transport of water. We present a quantitative model that predicts hydration and water transport in SC that is covered by such a film. We also develop an experimental method for measuring the specific resistance to water transport of films made of occluding barrier creams. Finally, we combine the theoretical model with the measured properties of the barrier creams to predict how a film of cream changes the activity of water at the outer surface of the SC. Using the known variations of SC permeability and hydration with the water activity in its environment (i.e. the relative humidity), we can thus predict how a film of barrier cream changes SC hydration.

  8. Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder.

    Science.gov (United States)

    Wang, Jou-Kou; Wu, Mei-Hwan; Lin, Ming-Tai; Chiu, Shuenn-Nan; Chen, Chun-An; Chiu, Hsin-Hui

    2010-02-01

    There are difficulties in transcatheter closure of patent ductus arteriosus (PDA) in infants. The 46 infants (mean age 6.2+/-2.7 months; mean body weight 6.3+/-1.6 kg) who underwent PDA closure using the Amplatzer duct occluder (ADO). The indication for using an ADO was a ductus diameter > or =2.5 or 3 mm. Device diameter selected was 1-3 mm larger than ductal diameter. The mean systolic pulmonary artery pressure was 40.9+/-18.2 mmHg. The mean Qp/Qs ratio was 3.1+/-1.2. The mean ductus diameter was 3.3+/-0.8 mm. ADO was successfully deployed in 45 patients. Failure occurred in 1 case. The mean diameter of device used was 5.4+/-1.1 mm. No severe complications occurred. At the 1-month echocardiographic follow-up, a small residual shunt was present in 4 of 45 patients and had disappeared in all 4 patients at the 3-month follow-up. One patient developed a moderate degree of left ventricular outflow tract obstruction 2.3 years after the procedure. Transcatheter closure of PDA in infants using the ADO is a safe and effective method.

  9. The production of phytolith-occluded carbon in China's forests: implications to biogeochemical carbon sequestration.

    Science.gov (United States)

    Song, Zhaoliang; Liu, Hongyan; Li, Beilei; Yang, Xiaomin

    2013-09-01

    The persistent terrestrial carbon sink regulates long-term climate change, but its size, location, and mechanisms remain uncertain. One of the most promising terrestrial biogeochemical carbon sequestration mechanisms is the occlusion of carbon within phytoliths, the silicified features that deposit within plant tissues. Using phytolith content-biogenic silica content transfer function obtained from our investigation, in combination with published silica content and aboveground net primary productivity (ANPP) data of leaf litter and herb layer in China's forests, we estimated the production of phytolith-occluded carbon (PhytOC) in China's forests. The present annual phytolith carbon sink in China's forests is 1.7 ± 0.4 Tg CO2  yr(-1) , 30% of which is contributed by bamboo because the production flux of PhytOC through tree leaf litter for bamboo is 3-80 times higher than that of other forest types. As a result of national and international bamboo afforestation and reforestation, the potential of phytolith carbon sink for China's forests and world's bamboo can reach 6.8 ± 1.5 and 27.0 ± 6.1 Tg CO2  yr(-1) , respectively. Forest management practices such as bamboo afforestation and reforestation may significantly enhance the long-term terrestrial carbon sink and contribute to mitigation of global climate warming. © 2013 John Wiley & Sons Ltd.

  10. Amplatzer angled duct occluder for closure of patent ductus arteriosus larger than the aorta in an infant.

    Science.gov (United States)

    Vijayalakshmi, I B; Chitra, N; Rajasri, R; Prabhudeva, A N

    2005-01-01

    Transcatheter closure of patent ductus arteriosus (PDA) by Amplatzer duct occluder is the treatment of choice. However, closure of very large ducts in infants with low weight is a challenge for the interventionalist because a large device may obstruct the aorta or left pulmonary artery. Difficulty is also encountered in advancing the device around the curve of the right ventricular outflow tract toward the pulmonary artery; this curve is tight, more or less at a right angle in infants, leading to kinking of the sheath, which increases fluoroscopic time. This is the first reported case of a very large PDA (8.7 mm), larger than the aorta (8.2 mm), successfully closed by an Amplatzer angled duct occluder in an infant weighing 5 kg.

  11. Cryopreserved recombinant tissue plasminogen activator for the restoration of occluded central venous access devices in pediatric oncology patients

    International Nuclear Information System (INIS)

    Iqbal, Y.; Al-Katheri, A.; Al-Sedairy, R.; Al-Omari, A.; Abdullah, Mohammed F.; Crankson, S.

    2002-01-01

    Thrombolytic therapy with urokinase 5000 units has been the standard therapy for restoration of thrombosed central catheters. However, with the decreased availability of urokinase, alternatives needed to be sought. The aim of the study was to determine the efficacy, bioactivity, dwell time and cost of cryopreserved recombinant tissue plasminogen activator (rTPA) in the restoration of occluded central venous access devices. For children 10kg, a dose of 1 mg was used. The dwell time was 1-2 hours. Of the 40 courses of rTPA, 39 fully restored central venous line patency (97%). Successful courses were instilled for an average of 1 hour. Cryopreserved rTPA appears to be safe and effective in the dose used to restore the patency of occluded central venous access devices in pediatric oncology patients. (author)

  12. Anatomy-based reconstruction of FDG-PET images with implicit partial volume correction improves detection of hypometabolic regions in patients with epilepsy due to focal cortical dysplasia diagnosed on MRI

    International Nuclear Information System (INIS)

    Goffin, Karolien; Baete, Kristof; Nuyts, Johan; Laere, Koen van; Van Paesschen, Wim; Dupont, Patrick; Palmini, Andre

    2010-01-01

    Detection of hypometabolic areas on interictal FDG-PET images for assessing the epileptogenic zone is hampered by partial volume effects. We evaluated the performance of an anatomy-based maximum a-posteriori (A-MAP) reconstruction algorithm which combined noise suppression with correction for the partial volume effect in the detection of hypometabolic areas in patients with focal cortical dysplasia (FCD). FDG-PET images from 14 patients with refractory partial epilepsy were reconstructed using A-MAP and maximum likelihood (ML) reconstruction. In all patients, presurgical evaluation showed that FCD represented the epileptic lesion. Correspondence between the FCD location and regional metabolism on a predefined atlas was evaluated. An asymmetry index of FCD to normal cortex was calculated. Hypometabolism at the FCD location was detected in 9/14 patients (64%) using ML and in 10/14 patients (71%) using A-MAP reconstruction. Hypometabolic areas outside the FCD location were detected in 12/14 patients (86%) using ML and in 11/14 patients (79%) using A-MAP reconstruction. The asymmetry index was higher using A-MAP reconstruction (0.61, ML 0.49, p=0.03). The A-MAP reconstruction algorithm improved visual detection of epileptic FCD on brain FDG-PET images compared to ML reconstruction, due to higher contrast and better delineation of the lesion. This improvement failed to reach significance in our small sample. Hypometabolism outside the lesion is often present, consistent with the observation that the functional deficit zone tends to be larger than the epileptogenic zone. (orig.)

  13. Anatomy-based reconstruction of FDG-PET images with implicit partial volume correction improves detection of hypometabolic regions in patients with epilepsy due to focal cortical dysplasia diagnosed on MRI

    Energy Technology Data Exchange (ETDEWEB)

    Goffin, Karolien; Baete, Kristof; Nuyts, Johan; Laere, Koen van [University Hospital Leuven, Division of Nuclear Medicine and Medical Imaging Center, Leuven (Belgium); Van Paesschen, Wim [University Hospital Leuven, Neurology Department, Leuven (Belgium); Dupont, Patrick [University Hospital Leuven, Division of Nuclear Medicine and Medical Imaging Center, Leuven (Belgium); University Hospital Leuven, Laboratory of Cognitive Neurology, Leuven (Belgium); Palmini, Andre [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre Epilepsy Surgery Program, Hospital Sao Lucas, Porto Alegre (Brazil)

    2010-06-15

    Detection of hypometabolic areas on interictal FDG-PET images for assessing the epileptogenic zone is hampered by partial volume effects. We evaluated the performance of an anatomy-based maximum a-posteriori (A-MAP) reconstruction algorithm which combined noise suppression with correction for the partial volume effect in the detection of hypometabolic areas in patients with focal cortical dysplasia (FCD). FDG-PET images from 14 patients with refractory partial epilepsy were reconstructed using A-MAP and maximum likelihood (ML) reconstruction. In all patients, presurgical evaluation showed that FCD represented the epileptic lesion. Correspondence between the FCD location and regional metabolism on a predefined atlas was evaluated. An asymmetry index of FCD to normal cortex was calculated. Hypometabolism at the FCD location was detected in 9/14 patients (64%) using ML and in 10/14 patients (71%) using A-MAP reconstruction. Hypometabolic areas outside the FCD location were detected in 12/14 patients (86%) using ML and in 11/14 patients (79%) using A-MAP reconstruction. The asymmetry index was higher using A-MAP reconstruction (0.61, ML 0.49, p=0.03). The A-MAP reconstruction algorithm improved visual detection of epileptic FCD on brain FDG-PET images compared to ML reconstruction, due to higher contrast and better delineation of the lesion. This improvement failed to reach significance in our small sample. Hypometabolism outside the lesion is often present, consistent with the observation that the functional deficit zone tends to be larger than the epileptogenic zone. (orig.)

  14. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].

    Science.gov (United States)

    Parra-Bravo, José Rafael; Apolonio-Martínez, Adriana; Estrada-Loza, María de Jesús; Beirana-Palencia, Luisa Gracia; Ramírez-Portillo, César Iván

    2015-01-01

    The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusionductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  15. Hepatic Encephalopathy Secondary to Intrahepatic Portosystemic Venous Shunt: Balloon-Occluded Retrograde Transvenous Embolization with n-Butyl Cyanoacrylate and Microcoils

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Nakamura, Toshiyuki; Iida, Shigeharu; Kato, Takeharu; Tanaka, Osamu; Matsushima, Shigenori; Ito, Hirotoshi; Okuyama, Chio; Ushijima, Yo; Shiga, Kensuke; Nishimura, Tsunehiko

    2002-01-01

    We report a 70-year-old woman with hepatic encephalopathy due to an intrahepatic portosystemic venous shunt that was successfully occluded by percutaneous transcatheter embolization with n-butyl cyanoacrylate and microcoils

  16. Transcatheter closure of patent ductus arteriosus and interruption of inferior vena cava with azygous continuation using an Amplatzer duct occluder II

    Directory of Open Access Journals (Sweden)

    Koh Ghee

    2009-01-01

    Full Text Available We report a case of transcatheter closure of patent ductus arteriosus using the new Amplatzer duct occluder II in an adult patient with interrupted inferior vena cava with azygous continuation via the femoral artery approach.

  17. Transcatheter occlusion of perimembranous ventricular septal defects with Amplatzer duct occluder

    International Nuclear Information System (INIS)

    Ren Sengen; Kang Kang; Wu Danning; Shi Hong; Wu Jingzhang; Yang Mei; Han Feizhou; Zhou Fei; Zhu Zhijun

    2003-01-01

    Objective: To study the feasibility of congenital perimembranous ventricular septal defect (VSD) occlusion by Amplatzer duct occluder (ADO) and to establish guidelines for its safe and effective application. Methods: From May 2001 to December 2002, percutaneous transcatheter occlusion of congenital perimembranous VSD was performed in 41 patients, in which 18 patients had an associated aneurysm of the membranous septum. There were 20 male and 21 female subjects, with age ranging from 6 to 38 years (median 14.9) and weights of 18 to 62 kg (median 41.5). The diameter of VSD ranged from 4 to 12.8 mm (median 6.0), and the distance of VSD to the aortic valve were 4.5 to 12 mm (median 6.6). The ratio of pulmonary to systemic blood flow (Qp/Qs) was 1.4 to 2.6 (median 1.7) and the pulmonary systolic pressure was 19 to 34 mmHg (median 25). Results: All the patients underwent successfully complete occlusion of VSD with ADO, and the size of ADO ranged from 6/4 to 16/14 mm. After the procedure, left ventricular angiography and transthoracic echocardiography showing the ADOs were precisely placed inside the VSDs with no residual shunt and also no abnormalities revealed by auscultation. Chest X-ray showed the relief of congestion of the lungs. Electrocardiogram demonstrated complete left bundle branch block in one case and incomplete right bundle branch block in other 12 cases, all disappeared within 1 to 2 weeks. Over a period of 2 to 21 months follow-up, all the devices maintained in good position and the patients' condition turned much better. No patient developed aortic or tricuspid regurgitation and other complications. Conclusions: ADO is a safe, effective and convenient occlusion device which could be practically applied for the congenital perimembranous VSDs

  18. Occlusion of blood flow attenuates exercise-induced hypoalgesia in the occluded limb of healthy adults.

    Science.gov (United States)

    Jones, Matthew D; Taylor, Janet L; Barry, Benjamin K

    2017-05-01

    Animal studies have demonstrated an important role of peripheral mechanisms as contributors to exercise-induced hypoalgesia (EIH). Whether these same mechanisms contribute to EIH in humans is not known. In the current study, pain thresholds were assessed in healthy volunteers ( n = 36) before and after 5 min of high-intensity leg cycling exercise and an equivalent period of quiet rest. Pressure pain thresholds (PPTs) were assessed over the rectus femoris muscle of one leg and first dorsal interosseous muscles (FDIs) of both arms. Blood flow to one arm was occluded by a cuff throughout the 5-min period of exercise (or rest) and postexercise (or rest) assessments. Ratings of pain intensity and pain unpleasantness during occlusion were also measured. Pain ratings during occlusion increased over time (range, 1.5 to 3.5/10, all d > 0.63, P exercise conditions ( d 0.4). PPTs at all sites were unchanged following rest (range, -1.3% to +0.9%, all d 0.51). Consistent with EIH, exercise significantly increased PPT at the leg (+29%, d = 0.69, P exercise attenuates EIH, suggesting that peripheral factors contribute to EIH in healthy adults. NEW & NOTEWORTHY This is the first demonstration in humans that a factor carried by the circulation and acting at the periphery is important for exercise-induced hypoalgesia. Further understanding of this mechanism may provide new insight to pain relief with exercise as well as potential interactions between analgesic medications and exercise. Copyright © 2017 the American Physiological Society.

  19. Is the new Occlutech duct occluder an appropriate device for transcatheter closure of patent ductus arteriosus?

    Science.gov (United States)

    Godart, François; Houeijeh, Ali; Domanski, Olivia; Guillaume, Marie-Paule; Brard, Mélanie; Lucron, Hugues

    2018-06-15

    To describe our initial experience with the Occlutech Duct Occluder (ODO) for percutaneous closure of patent ductus arteriosus (PDA). Retrospective review of patients undergoing transcatheter PDA closure with the ODO in 2 academic centers. From April 2013 to September 2017, 42 patients underwent PDA closure. Median age at implantation was 34 months (range 4 months-68 years) and median weight was 12 kg (range 4.1-57 kg). Ducts were Krichenko type A duct (n = 34), type E (n = 6), and type C (n = 2). The mean duct diameter was 3.76 mm (range 1.69 to 9.95 mm, median 3.1 mm). Implantation succeeded in all. There was neither device embolization nor hemolysis. At device release, immediate angiogram showed a small residual shunt in 54.7%. During follow-up, Doppler echocardiography demonstrated 71% of full occlusion at day one, rising to 95% at one month and 100% at one year and half after implantation. The mean maximal systolic pressure gradient in left pulmonary artery was 4.2 ± 4.3 mm and across the distal aortic arch 5.4 ± 4.7 mm Hg. No patient had any significant stenosis with clinical relevance. ODO is safe and effective in transcatheter closure of PDA including relatively large sized ducts. The results are satisfactory with a high level of full occlusion and a low rate of complications. Further evaluation with larger studies and longer follow-up will be required to confirm these preliminary good results. Copyright © 2018. Published by Elsevier B.V.

  20. Estimation of an image derived input function with MR-defined carotid arteries in FDG-PET human studies using a novel partial volume correction method

    DEFF Research Database (Denmark)

    Sari, Hasan; Erlandsson, Kjell; Law, Ian

    2017-01-01

    Kinetic analysis of18F-fluorodeoxyglucose positron emission tomography data requires an accurate knowledge the arterial input function. The gold standard method to measure the arterial input function requires collection of arterial blood samples and is an invasive method. Measuring an image deriv...... input function (p > 0.12 for grey matter and white matter). Hence, the presented image derived input function extraction method can be a practical alternative to noninvasively analyze dynamic18F-fluorodeoxyglucose data without the need for blood sampling....

  1. Partial volume effect in MRI

    International Nuclear Information System (INIS)

    Maeda, Munehiro; Yoshiya, Kazuhiko; Suzuki, Eiji

    1989-01-01

    According to the direction and the thickness of the imaging slice in tomography, the border between the tissues becomes unclear (partial volume effect). In the present MRI experiment, we examined border area between fat and water components using phantom in order to investigate the partial volume effect in MRI. In spin echo sequences, the intensity of the border area showed a linear relationship with composition of fat and water. Whereas, in inversion recovery and field echo sequences, we found the parameters to produce an extremely low intensity area at the border region between fat and water. This low intensity area was explained by cancellation of NMR signals from fat and water due to the difference in the direction of magnetic vectors. Clinically, partial volume effect can cause of mis-evaluation of walls, small nodules, tumor capsules and the tumor invasion in the use of inversion recovery and field echo sequences. (author)

  2. Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm

    International Nuclear Information System (INIS)

    Wintersperger, Bernd J.; Nikolaou, Konstantin; Dietrich, Olaf; Reiser, Maximilian F.; Schoenberg, Stefan O.; Rieber, Johannes; Nittka, Matthias

    2003-01-01

    The purpose of this study was to test parallel imaging techniques for improvement of temporal resolution in multislice single breath-hold real-time cine steady-state free precession (SSFP) in comparison with standard segmented single-slice SSFP techniques. Eighteen subjects were examined on a 1.5-T scanner using a multislice real-time cine SSFP technique using the GRAPPA algorithm. Global left ventricular parameters (EDV, ESV, SV, EF) were evaluated and results compared with a standard segmented single-slice SSFP technique. Results for EDV (r=0.93), ESV (r=0.99), SV (r=0.83), and EF (r=0.99) of real-time multislice SSFP imaging showed a high correlation with results of segmented SSFP acquisitions. Systematic differences between both techniques were statistically non-significant. Single breath-hold multislice techniques using GRAPPA allow for improvement of temporal resolution and for accurate assessment of global left ventricular functional parameters. (orig.)

  3. Restoration of Patency to Central Airways Occluded by Malignant Endobronchial Tumors Using Intratumoral Injection of Cisplatin.

    Science.gov (United States)

    Mehta, Hiren J; Begnaud, Abbie; Penley, Andrea M; Wynne, John; Malhotra, Paras; Fernandez-Bussy, Sebastian; Cope, Jessica; Shuster, Jonathan J; Jantz, Michael A

    2015-09-01

    -center retrospective study and a subjective primary outcome measure, we have demonstrated the feasibility of improving the patency of central airways that are largely or completely occluded by endobronchial malignant tumor using intraluminal injection of cisplatin. Additional longer-term, larger-scale safety and comparative effectiveness studies of this palliative treatment modality are warranted.

  4. Predicting 3D pose in partially overlapped X-ray images of knee prostheses using model-based Roentgen stereophotogrammetric analysis (RSA).

    Science.gov (United States)

    Hsu, Chi-Pin; Lin, Shang-Chih; Shih, Kao-Shang; Huang, Chang-Hung; Lee, Chian-Her

    2014-12-01

    After total knee replacement, the model-based Roentgen stereophotogrammetric analysis (RSA) technique has been used to monitor the status of prosthetic wear, misalignment, and even failure. However, the overlap of the prosthetic outlines inevitably increases errors in the estimation of prosthetic poses due to the limited amount of available outlines. In the literature, quite a few studies have investigated the problems induced by the overlapped outlines, and manual adjustment is still the mainstream. This study proposes two methods to automate the image processing of overlapped outlines prior to the pose registration of prosthetic models. The outline-separated method defines the intersected points and segments the overlapped outlines. The feature-recognized method uses the point and line features of the remaining outlines to initiate registration. Overlap percentage is defined as the ratio of overlapped to non-overlapped outlines. The simulated images with five overlapping percentages are used to evaluate the robustness and accuracy of the proposed methods. Compared with non-overlapped images, overlapped images reduce the number of outlines available for model-based RSA calculation. The maximum and root mean square errors for a prosthetic outline are 0.35 and 0.04 mm, respectively. The mean translation and rotation errors are 0.11 mm and 0.18°, respectively. The errors of the model-based RSA results are increased when the overlap percentage is beyond about 9%. In conclusion, both outline-separated and feature-recognized methods can be seamlessly integrated to automate the calculation of rough registration. This can significantly increase the clinical practicability of the model-based RSA technique.

  5. Partial tooth gear bearings

    Science.gov (United States)

    Vranish, John M. (Inventor)

    2010-01-01

    A partial gear bearing including an upper half, comprising peak partial teeth, and a lower, or bottom, half, comprising valley partial teeth. The upper half also has an integrated roller section between each of the peak partial teeth with a radius equal to the gear pitch radius of the radially outwardly extending peak partial teeth. Conversely, the lower half has an integrated roller section between each of the valley half teeth with a radius also equal to the gear pitch radius of the peak partial teeth. The valley partial teeth extend radially inwardly from its roller section. The peak and valley partial teeth are exactly out of phase with each other, as are the roller sections of the upper and lower halves. Essentially, the end roller bearing of the typical gear bearing has been integrated into the normal gear tooth pattern.

  6. Long-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder

    Science.gov (United States)

    Behjati-Ardakani, Mostafa; Behjati-Ardakani, Mohammad-Amin; Hosseini, Seyed-Habibolla; Noori, Noormohammad

    2013-01-01

    Objective Patent ductus arteriosus (PDA) is one of the most frequently seen congenital heart diseases. Its closure is recommended because of the risk of infective endocardis, as well as morbidity and mortality in the long. The aim of this study was to assess the long term results of the transcatheter closure of PDA in infants using amplatzer duct occlude (ADO). Methods From May 2004 to September 2011, forty eight infants underwent transcatheter closure of PDA. A lateral or right anterior oblique view aortogram was done to locate PDA and to measure its size. Before discharge, repeat aortogram was performed to evaluate eventual residual shunt and to confirm the appropriate deployment of the ADO. Follow up evaluations were done with transthoracic echocardiography at discharge, 1 month, 6 months, 12 months and yearly thereafter. Findings The mean age of patients at procedure was 9.18±2.32 (range 3 to 12) months, mean weight 6.73±1.16 (range 4.5 to 10.1) kg. The PDA occluded completely in 20 out of the 48 patients. Twenty four patients had trivial or mild shunt and two patients had moderate residual shunt which disappeared in one patient within 24 hours and other patient with moderate shunt in 1 month. One patient (age 8 months) had mild LPA stenosis. The device emobolization occurred in two patients, immediately after the procedure in one and during night in the other patient Conclusion The long term results suggested that transcatheter closure of PDA using Amplatzer duct occluder is a safe and effective treatment in infants less than 1 year of age with minimal complications. PMID:24427494

  7. Essays on partial retirement

    NARCIS (Netherlands)

    Kantarci, T.

    2012-01-01

    The five essays in this dissertation address a range of topics in the micro-economic literature on partial retirement. The focus is on the labor market behavior of older age groups. The essays examine the economic and non-economic determinants of partial retirement behavior, the effect of partial

  8. Recurrent Partial Words

    Directory of Open Access Journals (Sweden)

    Francine Blanchet-Sadri

    2011-08-01

    Full Text Available Partial words are sequences over a finite alphabet that may contain wildcard symbols, called holes, which match or are compatible with all letters; partial words without holes are said to be full words (or simply words. Given an infinite partial word w, the number of distinct full words over the alphabet that are compatible with factors of w of length n, called subwords of w, refers to a measure of complexity of infinite partial words so-called subword complexity. This measure is of particular interest because we can construct partial words with subword complexities not achievable by full words. In this paper, we consider the notion of recurrence over infinite partial words, that is, we study whether all of the finite subwords of a given infinite partial word appear infinitely often, and we establish connections between subword complexity and recurrence in this more general framework.

  9. Dose modeling of noninvasive image-guided breast brachytherapy in comparison to electron beam boost and three-dimensional conformal accelerated partial breast irradiation.

    Science.gov (United States)

    Sioshansi, Shirin; Rivard, Mark J; Hiatt, Jessica R; Hurley, Amanda A; Lee, Yoojin; Wazer, David E

    2011-06-01

    To perform dose modeling of a noninvasive image-guided breast brachytherapy (NIIGBB) for comparison to electrons and 3DCRT. The novel technology used in this study is a mammography-based, noninvasive breast brachytherapy system whereby the treatment applicators are centered on the planning target volume (PTV) to direct (192)Ir emissions along orthogonal axes. To date, three-dimensional dose modeling of NIIGBB has not been possible because of the limitations of conventional treatment planning systems (TPS) to model variable tissue deformation associated with breast compression. In this study, the TPS was adapted such that the NIIGBB dose distributions were modeled as a virtual point source. This dose calculation technique was applied to CT data from 8 patients imaged with the breast compressed between parallel plates in the cranial-caudal and medial-lateral axes. A dose-volume comparison was performed to simulated electron boost and 3DCRT APBI. The NIIGBB PTV was significantly reduced as compared with both electrons and 3DCRT. Electron boost plans had a lower D(min) than the NIIGBB technique but higher V(100), D(90), and D(50). With regard to PTV coverage for APBI, the only significant differences were minimally higher D(90), D(100), V(80), and V(90), with 3DCRT and D(max) with NIIGBB. The NIIGBB technique, as compared with electrons and 3D-CRT, achieved a lower maximum dose to skin (60% and 10%, respectively) and chest wall/lung (70-90%). NIIGBB achieves a PTV that is smaller than electron beam and 3DCRT techniques. This results in significant normal tissue sparing while maintaining dosimetric benchmarks to the target tissue. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Detection of weed locations in leaf occluded cereal crops using a fully convolutional neural network

    DEFF Research Database (Denmark)

    Dyrmann, Mads; Nyholm Jørgensen, Rasmus; Midtiby, Henrik Skov

    2017-01-01

    This pap er presents a metho d for au tomating weed detectio n in colour images despite heavy lea f occlusion. A fully convolu tio n al neural network is used to detect the weed s. The netwo rk is trained and validated on a tot al of more than 17,000 ann otations of w eeds in images from wint er w...

  11. Survey report on energy transportation systems which use hydrogen-occluding alloys; Suiso kyuzo gokin wo riyoshita energy yuso system chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-03-18

    Surveyed are systems which use hydrogen-occluding alloys for, e.g., storing and transporting hydrogen. This project is aimed at development of, and extraction of technical problems involved in, the concept of hydrogen energy transportation cycles for producing hydrogen in overseas countries by electrolysis using clean energy of hydraulic energy which are relatively cheap there; transporting hydrogen stored in a hydrogen-occluding alloy by sea to Japan; and converting it into electrical power to be delivered and used there. The surveyed items include current state of development/utilization of hydraulic power resources in overseas countries; pigeonholing the technical issues involved in the hydrogen transportation cycles, detailed studies thereon, and selection of the transportation cycles; current state of research, development and application of hydrogen-occluding alloys for various purposes; extraction of the elementary techniques for the techniques and systems for the hydrogen transportation systems which use hydrogen-occluding alloys; research themes of the future hydrogen-occluding alloys and the application techniques therefor, and research and development thereof; and legislative measures and safety. (NEDO)

  12. Efficacy of electrocoagulation in sealing the cystic artery and cystic duct occluded with only one absorbable clip during laparoscopic cholecystectomy.

    Science.gov (United States)

    Yang, Chang-Ping; Cao, Jin-Lin; Yang, Ren-Rong; Guo, Hong-Rong; Li, Zhao-Hui; Guo, Hai-Ying; Shao, Yin-Can; Liu, Gui-Bao

    2014-02-01

    Even though laparoscopic cholecystectomy (LC) emerged over 20 years ago, controversies persist with regard to the best method to ligate the cystic duct and artery. We proposed to assess the effectiveness and safety of electrocoagulation to seal the cystic artery and cystic duct after their occlusion with only one absorbable clip. We retrospectively compared the clinical data for 635 patients undergoing LC using electrocoagulation to seal the cystic artery and cystic duct that were occluded with only one absorbable clip (Group 1) and 728 patients undergoing LC using titanium clips (Group 2). In parallel, 30 rabbits randomized into six groups underwent cholecystectomy. After cystic duct ligation with absorbable or titanium clips, the animals were sacrificed 1, 3, or 6 months later, and intraabdominal adhesions were assessed after celiotomy. The mean operative time was significantly shorter (41.6 versus 58.9 minutes, PElectrocoagulation of the cystic artery and cystic duct that were occluded with only one absorbable clip is safe and effective during LC. This approach is associated with shortened operative times and reduced leakage, compared with the standard method using metal clips.

  13. ST-depression in right precordial leads with inferior STEMI and occluded right coronary artery: intertwined anatomy and ischemic areas.

    Science.gov (United States)

    De Gennaro, Luisa; Brunetti, Natale Daniele; Ruggiero, Massimo; Rutigliano, David; Locuratolo, Nicola; Di Biase, Matteo; Caldarola, Pasquale

    2017-10-01

    Right coronary artery (RCA) occlusion in inferior acute myocardial infarction is usually heralded by ST-elevation both in inferior and in right precordial leads. We report the case of a 68-year-old male, who presented marked ST-elevation in inferior leads, mirrored by ST-depression in anterior-septal and lateral leads. Right precordial lead electrocardiogram unexpectedly showed ST-depression V1R-V5R leads. Coronary angiography showed mid-left anterior descending (LAD) coronary near-complete occlusion with distal wrapping LAD. Left circumflex artery was not occluded, while RCA was occluded mid tract. The patient was treated with coronary angioplasty on RCA and LAD. Absence of ST-elevation in right precordial leads may be presumably explained by the presence of a large ischemic area distal to mid-LAD near-occlusive stenosis and of a long-wrapping LAD. Complex coronary anatomy and intertwined ischemic areas may underlie apparently discording electrocardiograms.

  14. Object Representations in Human Visual Cortex Formed Through Temporal Integration of Dynamic Partial Shape Views.

    Science.gov (United States)

    Orlov, Tanya; Zohary, Ehud

    2018-01-17

    the retina. The lateral occipital complex (LOC) represents shape faithfully in such conditions even if the object is partially occluded. However, shape must sometimes be reconstructed over both space and time. Such is the case in anorthoscopic perception, when an object is moving behind a narrow slit. In this scenario, spatial information is limited at any moment so the whole-shape percept can only be inferred by integration of successive shape views over time. We find that LOC carries shape-specific information recovered using such temporal integration processes. The shape representation is invariant to slit orientation and is similar to that evoked by a fully viewed image. Existing models of object recognition lack such capabilities. Copyright © 2018 the authors 0270-6474/18/380659-20$15.00/0.

  15. Budget impact analysis of the percutaneous septal occluder for treatment of ostium secundum atrial septal defects in the Brazilian Unified National Health System.

    Science.gov (United States)

    Senna, Kátia Marie Simões e; Sarti, Flavia Mori; Costa, Márcia Gisele Santos da; Nita, Marcelo Eidi; Santos, Marisa da Silva; Tura, Bernardo Rangel; Correia, Marcelo Goulart

    2015-08-01

    The aim of this study was to perform a budget impact analysis on the adoption of percutaneous occlusion of ostium secundum atrial septal defects in the Brazilian Unified National Health System. Costs were collected using micro-costing technique from medical records for each treatment technique (conventional surgery versus percutaneous septal occluder) at a public federal hospital specialized in high-complexity cardiology. The analysis showed that expenditures associated with percutaneous occlusion were lower than with conventional surgery, and sensitivity analysis confirmed the cost reduction in several scenarios, showing a significant budget impact with a 30% adoption rate for the percutaneous occluder (savings of approximately 1.5 million dollars per year). The study indicates that the adoption of the percutaneous septal occluder would mean cost savings of approximately 3.5 million dollars for the Brazilian public health system.

  16. Occluded Brescia-Cimino Hemodialysis Fistulas: Endovascular Treatment with Both Brachial Arterial and Venous Access Using the Pull-Through Technique

    International Nuclear Information System (INIS)

    Miyayama, Shiro; Matsui, Osamu; Taki, Keiichi; Minami, Tetsuya; Shinmura, Rieko; Ito, Chiharu; Takamatsu, Shigeyuki; Kobayashi, Miki; Ushiogi, Yashuyuki

    2005-01-01

    We retrospectively evaluated the usefulness of both arterial and venous access with the pull-through technique in endovascular treatment of totally occluded Brescia-Cimino fistulas. We treated 26 patients (17 men, 9 women; age range 43-82 years, mean age 66 years) with occluded Brescia-Cimino fistulas. First, the occluded segment was traversed from the antegrade brachial arterial access using a microcatheter-guidewire system. Second, the vein was retrogradely punctured after confirmation of all diseased segments, and a 0.014- or 0.016-inch guidewire was pulled through the venous access when the occluded segment was long. All interventions including thrombolysis, thromboaspiration, angioplasty, and stent placement were performed via the venous access. The occlusion was successfully crossed via the brachial arterial access in 23 patients (88%). In 2 patients it was done from the venous approach. In the remaining patient it was not possible to traverse the occluded segment. The pull-through technique was successful in all 19 attempts. Clinical success was achieved in 96%, the primary patency rates at 6, 12, and 18 months were 83%, 78%, and 69%, the primary assisted patency rates were 92%, 92%, and 72%, and the secondary patency rates were 92%, 92%, and 92%, respectively. Minor complications in 5 patients included venous perforation in 2 (8%), venous rupture in 1 (4%), and regional hematoma in 2 (8%). Our study suggests that endovascular treatments with both arterial and venous access using the pull-through technique are highly effective in restoring function in totally occluded Brescia-Cimino fistulas

  17. Construction of occluded recombinant baculoviruses containing the full-length cry1Ab and cry1Ac genes from Bacillus thuringiensis

    Directory of Open Access Journals (Sweden)

    B.M. Ribeiro

    1998-06-01

    Full Text Available The administration of baculoviruses to insects for bioassay purposes is carried out, in most cases, by contamination of food surfaces with a known amount of occlusion bodies (OBs. Since per os infection is the natural route of infection, occluded recombinant viruses containing crystal protein genes (cry1Ab and cry1Ac from Bacillus thuringiensis were constructed for comparison with the baculovirus prototype Autographa californica nucleopolyhedrovirus (AcNPV. The transfer vector pAcUW2B was used for construction of occluded recombinant viruses. The transfer vector containing the crystal protein genes was cotransfected with linearized DNA from a non-occluded recombinant virus. The isolation of recombinant viruses was greatly facilitated by the reduction of background "wild type" virus and the increased proportion of recombinant viruses. Since the recombinant viruses containing full-length and truncated forms of the crystal protein genes did not seem to improve the pathogenicity of the recombinant viruses when compared with the wild type AcNPV, and in order to compare expression levels of the full-length crystal proteins produced by non-occluded and occluded recombinant viruses the full-length cry1Ab and cry1Ac genes were chosen for construction of occluded recombinant viruses. The recombinant viruses containing full-length and truncated forms of the crystal protein genes did not seem to improve its pathogenicity but the size of the larvae infected with the recombinant viruses was significantly smaller than that of larvae infected with the wild type virus.

  18. Transcatheter Closure of a Chronic Iatrogenic Arteriovenous Fistula Between the Carotid Artery and the Brachiocephalic Vein with an Amplatzer Duct Occluder in Combination with a Carotid Stent

    International Nuclear Information System (INIS)

    Stasek, Josef; Lojik, Miroslav; Bis, Josef; Horak, David; Dusek, Jaroslav; Brtko, Miroslav; Polansky, Pavel; Babu, Anush; Vojacek, Jan

    2009-01-01

    We report an original method of transcatheter closure of an arteriovenous fistula using the combination of an Amplatzer PDA occluder and a carotid stent. The fistula was between the left carotid artery and the brachiocephalic vein. The patient had significant left-to-right shunt and was highly symptomatic. Due to the large orifice and pseudoaneurysmatic enlargement of the fistula, we had to use a large Amplatzer PDA occluder and the protruding part of the PDA device disk had to be covered with a carotid stent. The fistula was completely closed. The patient stopped having symptoms and, 2 years after the procedure, the effect persists.

  19. The two C-terminal tyrosines stabilize occluded Na/K pump conformations containing Na or K ions.

    Science.gov (United States)

    Vedovato, Natascia; Gadsby, David C

    2010-07-01

    Interactions of the three transported Na ions with the Na/K pump remain incompletely understood. Na/K pump crystal structures show that the extended C terminus of the Na,K-adenosine triphosphatase (ATPase) alpha subunit directly contacts transmembrane helices. Deletion of the last five residues (KETYY in almost all Na/K pumps) markedly lowered the apparent affinity for Na activation of pump phosphorylation from ATP, a reflection of cytoplasmic Na affinity for forming the occluded E1P(Na3) conformation. ATPase assays further suggested that C-terminal truncations also interfere with low affinity Na interactions, which are attributable to extracellular effects. Because extracellular Na ions traverse part of the membrane's electric field to reach their binding sites in the Na/K pump, their movements generate currents that can be monitored with high resolution. We report here electrical measurements to examine how Na/K pump interactions with extracellular Na ions are influenced by C-terminal truncations. We deleted the last two (YY) or five (KESYY) residues in Xenopus laevis alpha1 Na/K pumps made ouabain resistant by either of two kinds of point mutations and measured their currents as 10-mM ouabain-sensitive currents in Xenopus oocytes after silencing endogenous Xenopus Na/K pumps with 1 microM ouabain. We found the low affinity inhibitory influence of extracellular Na on outward Na/K pump current at negative voltages to be impaired in all of the C-terminally truncated pumps. Correspondingly, voltage jump-induced transient charge movements that reflect pump interactions with extracellular Na ions were strongly shifted to more negative potentials; this signals a several-fold reduction of the apparent affinity for extracellular Na in the truncated pumps. Parallel lowering of Na affinity on both sides of the membrane argues that the C-terminal contacts provide important stabilization of the occluded E1P(Na3) conformation, regardless of the route of Na ion entry into the

  20. Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS.

    Science.gov (United States)

    Morville, Patrice; Akhavi, Ahmad

    2017-10-01

    The advent of Amplatzer Duct Occluder II additional Size (ADOIIAS) provided the potential to close hemodynamic significant patent ductus arteriosus (HSPDA) and to analyze the feasibility, safety and efficacy of the device. Treatment of a patent ductus arteriosus (PDA) in very premature neonates is still a dilemma for the neonatalogist who has to consider its significance and has to choose among different treatment options. Because surgical ligation and medical therapy both have their drawbacks, interventional catheterization might provide an alternative means of closing HSPDA. Between September 2013 and June 2015, 32 premature infants with complications related to HSPDA defined by ultrasound (US) underwent transcatheter closure. The procedure was performed in the catheterization laboratory by venous cannulation without angiography. The position of the occluder was directed by X-ray and US. In particular we looked at procedural details, device size selection, complications, and short and mid-term outcomes. Thirty two premature infants, all of whom had clinical complications related to HSPDA, born at gestational ages ranging between 23.6 and 36 weeks (mean ± standard deviation 28 ± 3 weeks) underwent attempted transcatheter PDA closure using the ADOIIAS. Their mean age and weight at the time of procedure was 25 days (range 8-70 days) and 1373 g (range 680-2480 g), respectively. Ten infants weighed ≤1,000g. All ducts were tubular. The mean PDA and device waist diameters were 3.2 ± 0.6mm (range 2.2-4) and 4.4 ± 0.6 mm, respectively, and the mean PDA and device lengths 5.2 ± 2.0 mm (range 2-10) and 3.4 ± 1.3 mm. Median fluoroscopy and procedural times were 11 min (range 3-24) and 28 min (range 10-90), respectively. Complete closure was achieved in all but one patient. There was no device migration. A left pulmonary artery (LPA) obstruction developed in one patient. Five infants died. Four deaths were related to complications of

  1. Repfinder: Finding approximately repeated scene elements for image editing

    KAUST Repository

    Cheng, Ming-Ming

    2010-07-26

    Repeated elements are ubiquitous and abundant in both manmade and natural scenes. Editing such images while preserving the repetitions and their relations is nontrivial due to overlap, missing parts, deformation across instances, illumination variation, etc. Manually enforcing such relations is laborious and error-prone. We propose a novel framework where user scribbles are used to guide detection and extraction of such repeated elements. Our detection process, which is based on a novel boundary band method, robustly extracts the repetitions along with their deformations. The algorithm only considers the shape of the elements, and ignores similarity based on color, texture, etc. We then use topological sorting to establish a partial depth ordering of overlapping repeated instances. Missing parts on occluded instances are completed using information from other instances. The extracted repeated instances can then be seamlessly edited and manipulated for a variety of high level tasks that are otherwise difficult to perform. We demonstrate the versatility of our framework on a large set of inputs of varying complexity, showing applications to image rearrangement, edit transfer, deformation propagation, and instance replacement. © 2010 ACM.

  2. Multi-modal imaging, model-based tracking, and mixed reality visualisation for orthopaedic surgery

    Science.gov (United States)

    Fuerst, Bernhard; Tateno, Keisuke; Johnson, Alex; Fotouhi, Javad; Osgood, Greg; Tombari, Federico; Navab, Nassir

    2017-01-01

    Orthopaedic surgeons are still following the decades old workflow of using dozens of two-dimensional fluoroscopic images to drill through complex 3D structures, e.g. pelvis. This Letter presents a mixed reality support system, which incorporates multi-modal data fusion and model-based surgical tool tracking for creating a mixed reality environment supporting screw placement in orthopaedic surgery. A red–green–blue–depth camera is rigidly attached to a mobile C-arm and is calibrated to the cone-beam computed tomography (CBCT) imaging space via iterative closest point algorithm. This allows real-time automatic fusion of reconstructed surface and/or 3D point clouds and synthetic fluoroscopic images obtained through CBCT imaging. An adapted 3D model-based tracking algorithm with automatic tool segmentation allows for tracking of the surgical tools occluded by hand. This proposed interactive 3D mixed reality environment provides an intuitive understanding of the surgical site and supports surgeons in quickly localising the entry point and orienting the surgical tool during screw placement. The authors validate the augmentation by measuring target registration error and also evaluate the tracking accuracy in the presence of partial occlusion. PMID:29184659

  3. Partial Deconvolution with Inaccurate Blur Kernel.

    Science.gov (United States)

    Ren, Dongwei; Zuo, Wangmeng; Zhang, David; Xu, Jun; Zhang, Lei

    2017-10-17

    Most non-blind deconvolution methods are developed under the error-free kernel assumption, and are not robust to inaccurate blur kernel. Unfortunately, despite the great progress in blind deconvolution, estimation error remains inevitable during blur kernel estimation. Consequently, severe artifacts such as ringing effects and distortions are likely to be introduced in the non-blind deconvolution stage. In this paper, we tackle this issue by suggesting: (i) a partial map in the Fourier domain for modeling kernel estimation error, and (ii) a partial deconvolution model for robust deblurring with inaccurate blur kernel. The partial map is constructed by detecting the reliable Fourier entries of estimated blur kernel. And partial deconvolution is applied to wavelet-based and learning-based models to suppress the adverse effect of kernel estimation error. Furthermore, an E-M algorithm is developed for estimating the partial map and recovering the latent sharp image alternatively. Experimental results show that our partial deconvolution model is effective in relieving artifacts caused by inaccurate blur kernel, and can achieve favorable deblurring quality on synthetic and real blurry images.Most non-blind deconvolution methods are developed under the error-free kernel assumption, and are not robust to inaccurate blur kernel. Unfortunately, despite the great progress in blind deconvolution, estimation error remains inevitable during blur kernel estimation. Consequently, severe artifacts such as ringing effects and distortions are likely to be introduced in the non-blind deconvolution stage. In this paper, we tackle this issue by suggesting: (i) a partial map in the Fourier domain for modeling kernel estimation error, and (ii) a partial deconvolution model for robust deblurring with inaccurate blur kernel. The partial map is constructed by detecting the reliable Fourier entries of estimated blur kernel. And partial deconvolution is applied to wavelet-based and learning

  4. Endovascular Mechanical Thrombectomy of an Occluded Superior Division Branch of the Left MCA for Acute Cardioembolic Stroke

    International Nuclear Information System (INIS)

    Schumacher, H. C.; Meyers, P. M.; Yavagal, D. R.; Harel, N. Y.; Elkind, M. S. V.; Mohr, J. P.; Pile-Spellman, J.

    2003-01-01

    Cardiac embolism accounts for a large proportion of ischemic stroke. Revascularization using systemic or intra-arterial thrombolysis is associated with increasing risks of cerebral hemorrhageas time passes from stroke onset. We report successful mechanicalthrombectomy from a distal branch of the middle cerebral artery (MCA)using a novel technique. A 72-year old man suffered an acute ischemic stroke from an echocardiographically proven ventricular thrombus due toa recent myocardial infarction. Intra-arterial administration of 4 mgrt-PA initiated at 5.7 hours post-ictus failed to recanalize an occluded superior division branch of the left MCA. At 6 hours,symptomatic embolic occlusion persisted. Mechanical extraction of the clot using an Attracter-18 device (Target Therapeutics, Freemont, CA) resulted in immediate recanalization of the MCA branch. Attracter-18 for acute occlusion of MCA branches may be considered in selected patients who fail conventional thrombolysis or are nearing closure of the therapeutic window for use of thrombolytic agents

  5. Balloon-Occluded Retrograde Transvenous Obliteration of a Gastric Vascular Malformation: An Innovative Approach to Treatment of a Rare Condition

    International Nuclear Information System (INIS)

    Hansing, Catherine E.; Marquardt, Joseph P.; Sutton, Daniel M.; York, John D.

    2017-01-01

    Arteriovenous malformations (AVMs) are a high-flow form of a vascular malformation, which can be found anywhere in the body. While historically treated surgically, a multidisciplinary approach utilizing multiple specialties and treatment modalities is now commonly employed. In order to effectively treat an AVM, the nidus must be targeted and eradicated, which can be done via multiple approaches. We present the case of a 43-year-old male with a gastric wall AVM, which was initially incompletely treated using a percutaneous transarterial approach. The gastric AVM was noted to have dominant drainage through a gastrorenal shunt; therefore, Balloon-occluded Retrograde Transvenous Obliteration (BRTO) was utilized to eradicate the AVM nidus. This case illustrates the utility of Interventional Radiology, specifically BRTO, as another treatment option for challenging AVMs.

  6. Balloon-Occluded Retrograde Transvenous Obliteration of a Gastric Vascular Malformation: An Innovative Approach to Treatment of a Rare Condition

    Energy Technology Data Exchange (ETDEWEB)

    Hansing, Catherine E., E-mail: catherine.e.hansing.mil@mail.mil [Naval Medical Center Portsmouth, Transitional Year/Graduate Medical Education Department, Medical Corps, United States Navy (United States); Marquardt, Joseph P.; Sutton, Daniel M.; York, John D. [Naval Medical Center Portsmouth, Radiology Department, Medical Corps, United States Navy (United States)

    2017-02-15

    Arteriovenous malformations (AVMs) are a high-flow form of a vascular malformation, which can be found anywhere in the body. While historically treated surgically, a multidisciplinary approach utilizing multiple specialties and treatment modalities is now commonly employed. In order to effectively treat an AVM, the nidus must be targeted and eradicated, which can be done via multiple approaches. We present the case of a 43-year-old male with a gastric wall AVM, which was initially incompletely treated using a percutaneous transarterial approach. The gastric AVM was noted to have dominant drainage through a gastrorenal shunt; therefore, Balloon-occluded Retrograde Transvenous Obliteration (BRTO) was utilized to eradicate the AVM nidus. This case illustrates the utility of Interventional Radiology, specifically BRTO, as another treatment option for challenging AVMs.

  7. Interventional Closure of a Patent Ductus Arteriosus Using an Amplatz Canine Duct Occluder in an Alpaca Cria.

    Science.gov (United States)

    Chapel, E C; Lozier, J; Lakritz, J; Schober, K E

    2017-07-01

    A 6-month old female alpaca cria presented to The Ohio State University for evaluation of a cardiac murmur. Echocardiography revealed a left-to-right shunting patent ductus arteriosus, a restrictive left-to-right shunting perimembranous ventricular septal defect, and secondary moderate left atrial and ventricular dilation. Aortic root angiography demonstrated a type IIA patent ductus arteriosus (PDA). Interventional closure of the PDA was successfully performed, without complication, using an Amplatz canine duct occluder. This case report describes the materials and methods used for interventional closure of a PDA in an alpaca cria. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  8. Transcatheter closure of tubular type patent ductus arteriosus using Amplatzer® ductal occluder II: a case report

    Directory of Open Access Journals (Sweden)

    Mulyadi M Djer

    2013-10-01

    In recent years, interventional cardiology has become a gold standard therapy for the majority of PDA cases beyond neonatal age. Since its introduction in 1967, many devices and methods have been developed to allow transcatheter closure of virtually all PDAs, regardless of size or configuration. Nevertheless, the tubular shape (type C PDA, which has the highest residual shunt rate, still poses a great challenge for the interventionist.8-10 The second generation of Amplatzer® device occluders (ADO II, released in 2007, has been suggested to be effective in closing tubular PDAs.10 The purpose of this study was to report the initial clinical experience using ADO II to close a tubular type PDA in Indonesia.

  9. Multicenter Off-Label Use of Nit-Occlud Coil in Retrograde Closure of Small Patent Ductus Arteriosus.

    Science.gov (United States)

    Zanjani, Keyhan Sayadpour; Sobhy, Rodina; El-Kaffas, Rania; El-Sisi, Amal

    2017-04-01

    We studied the safety and efficacy of closing patent ductus arteriosus by Nit-Occlud coils via retrograde approach. This is a retrospective study of 46 attempts to close ducts by this method in two hospitals in Egypt and Iran. Ductus arteriosus was crossed by left or right Judkins or endhole catheters. The coil was delivered via the same catheter or the provided endhole catheter after exchange. The procedure was successful in 42 out of 46 attempts. Fluoroscopy and procedural times were significantly shorter when the catheter was not exchanged. This method is effective and safe for the closure of small ducts. Crossing the duct and delivering the coil by a left Judkins catheter is the easiest and fastest way to perform this method.

  10. Immediate effects of the semi-occluded vocal tract exercise with LaxVox® tube in singers.

    Science.gov (United States)

    Fadel, Congeta Bruniere Xavier; Dassie-Leite, Ana Paula; Santos, Rosane Sampaio; Santos, Celso Gonçalves Dos; Dias, Cláudio Antônio Sorondo; Sartori, Denise Jussara

    The purpose of this study was to analyze the immediate effects of the semi-occluded vocal tract exercise (SOVTE) using the LaxVox® tube in singers. Participants were 23 singers, classical singing students, aged 18 to 47 years (mean age = 27.2 years). First, data was collected through the application of a demographic questionnaire and the recording of sustained emission - vowel /ε/, counting 1-10, and a music section from the participants' current repertoire. After that, the participants were instructed and performed the SOVTE using the LaxVox® tube for three minutes. Finally, the same vocal samples were collected immediately after SOVTE performance and the singers responded to a questionnaire on their perception regarding vocal changes after the exercise. The vocal samples were analyzed by referees (speech-language pathologists and singing teachers) and by means of acoustic analysis. Most of the singers reported improved voice post-exercise in both tasks - speech and singing. Regarding the perceptual assessment (sustained vowel, speech, and singing), the referees found no difference between pre- and post-exercise emissions. The acoustic analysis of the sustained vowel showed increased Fundamental Frequency (F0) and reduction of the Glottal to Noise Excitation (GNE) ratio post-exercise. The semi-occluded vocal tract exercise with LaxVox® tube promotes immediate positive effects on the self-assessment and acoustic analysis of voice in professional singers without vocal complains. No immediate significant changes were observed with respect to auditory-perceptual evaluation of speech and singing.

  11. Hand interception of occluded motion in humans: a test of model-based vs. on-line control.

    Science.gov (United States)

    La Scaleia, Barbara; Zago, Myrka; Lacquaniti, Francesco

    2015-09-01

    Two control schemes have been hypothesized for the manual interception of fast visual targets. In the model-free on-line control, extrapolation of target motion is based on continuous visual information, without resorting to physical models. In the model-based control, instead, a prior model of target motion predicts the future spatiotemporal trajectory. To distinguish between the two hypotheses in the case of projectile motion, we asked participants to hit a ball that rolled down an incline at 0.2 g and then fell in air at 1 g along a parabola. By varying starting position, ball velocity and trajectory differed between trials. Motion on the incline was always visible, whereas parabolic motion was either visible or occluded. We found that participants were equally successful at hitting the falling ball in both visible and occluded conditions. Moreover, in different trials the intersection points were distributed along the parabolic trajectories of the ball, indicating that subjects were able to extrapolate an extended segment of the target trajectory. Remarkably, this trend was observed even at the very first repetition of movements. These results are consistent with the hypothesis of model-based control, but not with on-line control. Indeed, ball path and speed during the occlusion could not be extrapolated solely from the kinematic information obtained during the preceding visible phase. The only way to extrapolate ball motion correctly during the occlusion was to assume that the ball would fall under gravity and air drag when hidden from view. Such an assumption had to be derived from prior experience. Copyright © 2015 the American Physiological Society.

  12. Application of Cardio-O-Fix occluders for transcatheter closure of patent ductus arteriosus and interatrial communications: Preliminary experience.

    Science.gov (United States)

    Białkowski, Jacek; Szkutnik, Małgorzata; Fiszer, Roland; Głowacki, Jan; Banaszak, Paweł; Zembala, Marian

    2010-01-01

    Transcatheter treatment has become the method of choice for treating many heart defects. Recently, Cardio-O-Fix occluder (COF) - a new, self-expandable nitinol wire-mesh device very similar to the Amplatzer device - has been introduced into clinical practice. To the best of our knowledge, this is the first publication related to its application. Five patients aged from six months to 69 years were included in the study: two with atrial septal defect (ASD), one with patent foramen ovale (PFO) after cryptogenic stroke, and two with patent ductus arteriosus (PDA). These latter two comprised one six month old infant with co-existent hypertrophied cardiomyopathy, and a 53 year-old woman with recanalized PDA after previous ligation. All were treated percutaneously with COF. There was no preliminary patient selection. The only limitation was the size of the devices in our possession (16 and 22 mm ASD COF, 25 PFO COF, 4/6 and 6/8 PDA COF). The implantation technique was the same as previously described for Amplatzer occluders. All procedures were finished successfully with complete closure of the shunt. No complications were observed during a six month follow-up. In the child with PDA, we observed decrease of gradient from 80 to 60 mm Hg in hypertrophied left ventricular outflow tract, although a small protrusion of PDA-COF device was noted in the descending aorta (8 mm Hg gradient in ECHO). In the patient with recanalized PDA, the procedure was performed after arterio-venous loop creation. Mean fluoroscopy time was 4.4 (range from 1.6 to 11) minutes. Our preliminary experience indicates that the application of Cardio-O-Fix devices is safe and effective.

  13. Different chemical composition of free light, occluded light and extractable SOM fractions in soils of Cerrado and tilled and untilled fielfds, Minas Gerais, Brazil: a pyrolysis-GC/MS study

    NARCIS (Netherlands)

    Buurman, P.; Roscob, R.

    2011-01-01

    To investigate both the effect of land-use systems on SOM characteristics and the effect of occlusion in aggregates on chemical composition of the occluded fraction, SOM fractions of soils under Cerrado, no-tillage and conventional tillage, were investigated. Free light, occluded light and

  14. Dendrimer and an active substance occluded in the dendrimer : a process for the preparation thereof and a process for releasing the active substance

    NARCIS (Netherlands)

    1998-01-01

    The invention relates to a dendrimer composition in which an effective number of the terminal functionalities are provided with blocking agents, and at least one active substance species is occluded in the dendrimer. A blocking agent is a sufficiently sterically sized compound which readily enters

  15. Hyperbolic partial differential equations

    CERN Document Server

    Witten, Matthew

    1986-01-01

    Hyperbolic Partial Differential Equations III is a refereed journal issue that explores the applications, theory, and/or applied methods related to hyperbolic partial differential equations, or problems arising out of hyperbolic partial differential equations, in any area of research. This journal issue is interested in all types of articles in terms of review, mini-monograph, standard study, or short communication. Some studies presented in this journal include discretization of ideal fluid dynamics in the Eulerian representation; a Riemann problem in gas dynamics with bifurcation; periodic M

  16. Successful removable partial dentures.

    Science.gov (United States)

    Lynch, Christopher D

    2012-03-01

    Removable partial dentures (RPDs) remain a mainstay of prosthodontic care for partially dentate patients. Appropriately designed, they can restore masticatory efficiency, improve aesthetics and speech, and help secure overall oral health. However, challenges remain in providing such treatments, including maintaining adequate plaque control, achieving adequate retention, and facilitating patient tolerance. The aim of this paper is to review the successful provision of RPDs. Removable partial dentures are a successful form of treatment for replacing missing teeth, and can be successfully provided with appropriate design and fabrication concepts in mind.

  17. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2011-01-01

    A rigorous, yet accessible, introduction to partial differential equations-updated in a valuable new edition Beginning Partial Differential Equations, Second Edition provides a comprehensive introduction to partial differential equations (PDEs) with a special focus on the significance of characteristics, solutions by Fourier series, integrals and transforms, properties and physical interpretations of solutions, and a transition to the modern function space approach to PDEs. With its breadth of coverage, this new edition continues to present a broad introduction to the field, while also addres

  18. Partial knee replacement - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100225.htm Partial knee replacement - series—Normal anatomy To use the sharing ... A.M. Editorial team. Related MedlinePlus Health Topics Knee Replacement A.D.A.M., Inc. is accredited ...

  19. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2014-01-01

    A broad introduction to PDEs with an emphasis on specialized topics and applications occurring in a variety of fields Featuring a thoroughly revised presentation of topics, Beginning Partial Differential Equations, Third Edition provides a challenging, yet accessible,combination of techniques, applications, and introductory theory on the subjectof partial differential equations. The new edition offers nonstandard coverageon material including Burger's equation, the telegraph equation, damped wavemotion, and the use of characteristics to solve nonhomogeneous problems. The Third Edition is or

  20. Partial differential equations

    CERN Document Server

    Evans, Lawrence C

    2010-01-01

    This text gives a comprehensive survey of modern techniques in the theoretical study of partial differential equations (PDEs) with particular emphasis on nonlinear equations. The exposition is divided into three parts: representation formulas for solutions; theory for linear partial differential equations; and theory for nonlinear partial differential equations. Included are complete treatments of the method of characteristics; energy methods within Sobolev spaces; regularity for second-order elliptic, parabolic, and hyperbolic equations; maximum principles; the multidimensional calculus of variations; viscosity solutions of Hamilton-Jacobi equations; shock waves and entropy criteria for conservation laws; and, much more.The author summarizes the relevant mathematics required to understand current research in PDEs, especially nonlinear PDEs. While he has reworked and simplified much of the classical theory (particularly the method of characteristics), he primarily emphasizes the modern interplay between funct...

  1. An in vivo assessment of the effects of using different implant abutment occluding materials on implant microleakage and the peri-implant microbiome

    Science.gov (United States)

    Rubino, Caroline

    Microleakage may be a factor in the progression of peri-implant pathology. Microleakage in implant dentistry refers to the passage of bacteria, fluids, molecules or ions between the abutment-implant interface to and from the surrounding periodontal tissues. This creates a zone of inflammation and reservoir of bacteria at the implant-abutment interface. Bone loss typically occurs within the first year of abutment connection and then stabilizes. It has not yet been definitively proven that the occurrence of microleakage cannot contribute to future bone loss or impede the treatment of peri-implant disease. Therefore, strategies to reduce or eliminate microleakage are sought out. Recent evidence demonstrates that the type of implant abutment channel occluding material can affect the amount of microleakage in an in vitro study environment. Thus, we hypothesize that different abutment screw channel occluding materials will affect the amount of observed microleakage, vis-a-vis the correlation between the microflora found on the abutment screw channel occluding material those found in the peri-implant sulcus. Additional objectives include confirming the presence of microleakage in vivo and assessing any impact that different abutment screw channel occluding materials may have on the peri-implant microbiome. Finally, the present study provides an opportunity to further characterize the peri-implant microbiome. Eight fully edentulous patients restored with at dental implants supporting screw-retained fixed hybrid prostheses were included in the study. At the initial appointment (T1), the prostheses were removed and the implants and prostheses were cleaned. The prostheses were then inserted with polytetrafluoroethylene tape (PTFE, TeflonRTM), cotton, polyvinyl siloxane (PVS), or synthetic foam as the implant abutment channel occluding material and sealed over with composite resin. About six months later (T2), the prostheses were removed and the materials collected. Paper

  2. Optimization of partial search

    International Nuclear Information System (INIS)

    Korepin, Vladimir E

    2005-01-01

    A quantum Grover search algorithm can find a target item in a database faster than any classical algorithm. One can trade accuracy for speed and find a part of the database (a block) containing the target item even faster; this is partial search. A partial search algorithm was recently suggested by Grover and Radhakrishnan. Here we optimize it. Efficiency of the search algorithm is measured by the number of queries to the oracle. The author suggests a new version of the Grover-Radhakrishnan algorithm which uses a minimal number of such queries. The algorithm can run on the same hardware that is used for the usual Grover algorithm. (letter to the editor)

  3. Trends in the incidence of benign pathological lesions at partial nephrectomy for presumed renal cell carcinoma in renal masses on preoperative computed tomography imaging. A single institute experience with 290 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung-Hwan; Park, Sang-Un; Rha, Koon-Ho; Choi, Young-Deuk; Hong, Sung-Joon; Yang, Seung-Choul; Mah, Sang-Yol; Chung, Byung-Ha [Health System, Yonsei Univ., Seoul (Korea, Republic of)

    2010-06-15

    The aim of this study was to determine trends in the incidence of benign lesions in patients undergoing surgery for suspicious renal masses on preoperative computed tomography scan. The records of 1065 patients who underwent open consecutive partial nephrectomy (PN) or radical nephrectomy (RN) between January 2001 and December 2008 were reviewed. Patients who underwent PN during the periods 2001-2002, 2003-2004, 2005-2006, and 2007-2008 were assigned to groups 1, 2, 3 and 4, respectively. The frequencies of benign and malignant lesions in these groups were assessed according to size and histology subtypes. The ratio of PN to RN was 12.4%, 18.3%, 24.3% and 37.2% in groups 1, 2, 3 and 4, respectively (P<0.05). The mean size of resected lesions was 2.6 cm (range 0.8-6.2 cm). Of the 290 cases, histopathology revealed benign findings in 52 (17.9%). Benign pathology was found in three of 18 cases (16.7%) in group 1, seven of 36 cases (19.4%) in group 2, 12 of 63 cases (19.0%) in group 3 and 30 of 173 cases (17.3%) in group 4. There was no significant difference in the frequency of benign histology among groups. PN, as opposed to RN, has shown a rising tendency over time. The frequency of benign pathology findings after PN for suspicious renal masses on preoperative computed tomography imaging has not decreased. Proper management should favor nephron-sparing surgery for renal lesions if such lesions can be removed satisfactorily with PN. (author)

  4. Imaging

    International Nuclear Information System (INIS)

    Kellum, C.D.; Fisher, L.M.; Tegtmeyer, C.J.

    1987-01-01

    This paper examines the advantages of the use of excretory urography for diagnosis. According to the authors, excretory urography remains the basic radiologic examination of the urinary tract and is the foundation for the evaluation of suspected urologic disease. Despite development of the newer diagnostic modalities such as isotope scanning, ultrasonography, CT, and magnetic resonsance imaging (MRI), excretory urography has maintained a prominent role in ruorradiology. Some indications have been altered and will continue to change with the newer imaging modalities, but the initial evaluation of suspected urinary tract structural abnormalities; hematuria, pyuria, and calculus disease is best performed with excretory urography. The examination is relatively inexpensive and simple to perform, with few contraindictions. Excretory urography, when properly performed, can provide valuable information about the renal parenchyma, pelvicalyceal system, ureters, and urinary bladder

  5. Initial Experience with Balloon-Occluded Trans-catheter Arterial Chemoembolization (B-TACE) for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Mitsunari, E-mail: mitunari@med-shimane.u.ac.jp; Yoshizako, Takeshi, E-mail: yosizako@med.shimane-u.ac.jp; Nakamura, Tomonori, E-mail: t-naka@med.shimane-u.ac.jp; Nakamura, Megumi, E-mail: megumi@med.shimane-u.ac.jp; Yoshida, Rika, E-mail: yoshidar@med.shimane-u.ac.jp; Kitagaki, Hajime, E-mail: kitagaki@med.shimane-u.ac.jp [Shimane University Faculty of Medicine, Department of Radiology (Japan)

    2016-03-15

    PurposeThis study was performed to evaluate the accumulation of lipiodol emulsion (LE) and adverse events during our initial experience of balloon-occluded trans-catheter arterial chemoembolization (B-TACE) for hepatocellular carcinoma (HCC) compared with conventional TACE (C-TACE).MethodsB-TACE group (50 cases) was compared with C-TACE group (50 cases). The ratio of the LE concentration in the tumor to that in the surrounding embolized liver parenchyma (LE ratio) was calculated after each treatment. Adverse events were evaluated according to the Common Terminology Criteria for Adverse Effects (CTCAE) version 4.0.ResultsThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). Only elevation of alanine aminotransferase was more frequent in the B-TACE group, showing a statistically significant difference (Mann–Whitney test: P < 0.05). While B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation, there was no statistically significant difference in incidence between the groups. Multivariate logistic regression analysis suggested that the significant risk factor for liver abscess/infarction was bile duct dilatation (P < 0.05).ConclusionThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation.

  6. Long-term intensive management increased carbon occluded in phytolith (PhytOC) in bamboo forest soils

    Science.gov (United States)

    Huang, Zhang-Ting; Li, Yong-Fu; Jiang, Pei-Kun; Chang, Scott X.; Song, Zhao-Liang; Liu, Juan; Zhou, Guo-Mo

    2014-01-01

    Carbon (C) occluded in phytolith (PhytOC) is highly stable at millennium scale and its accumulation in soils can help increase long-term C sequestration. Here, we report that soil PhytOC storage significantly increased with increasing duration under intensive management (mulching and fertilization) in Lei bamboo (Phyllostachys praecox) plantations. The PhytOC storage in 0-40 cm soil layer in bamboo plantations increased by 217 Mg C ha-1, 20 years after being converted from paddy fields. The PhytOC accumulated at 79 kg C ha-1 yr-1, a rate far exceeding the global mean long-term soil C accumulation rate of 24 kg C ha-1 yr-1 reported in the literature. Approximately 86% of the increased PhytOC came from the large amount of mulch applied. Our data clearly demonstrate the decadal scale management effect on PhytOC accumulation, suggesting that heavy mulching is a potential method for increasing long-term organic C storage in soils for mitigating global climate change.

  7. Flower specialisation: the occluded corolla of snapdragons (Antirrhinum) exhibits two pollinator niches of large long-tongued bees.

    Science.gov (United States)

    Vargas, P; Liberal, I; Ornosa, C; Gómez, J M

    2017-09-01

    Flower specialisation of angiosperms includes the occluded corollas of snapdragons (Antirrhinum and some relatives), which have been postulated to be one of the most efficient structures to physical limit access to pollinators. The Iberian Peninsula harbours the highest number of species (18 Iberian of the 20 species of Antirrhinum) that potentially share similar pollinator fauna. Crossing experiments with 18 Iberian species from this study and literature revealed a general pattern of self-incompatibility (SI) - failure in this SI system has been also observed in a few plants - which indicates the need for pollinator agents in Antirrhinum pollination. Field surveys in natural conditions (304 h) found flower visitation (>85%) almost exclusively by 11 species of bee (Anthophora fulvitarsis, Anthophora plumipes, Anthidium sticticum, Apis mellifera, Bombus hortorum, Bombus pascuorum, Bombus ruderatus, Bombus terrestris, Chalicodoma lefebvrei, Chalicodoma pyrenaica and Xylocopa violacea). This result covering the majority of Antirrhinum species suggests that large bees of the two long-tongued bee families (Megachilidae, Apidae) are the major pollinators of Antirrhinum. A bipartite modularity analysis revealed two pollinator systems of long-tongued bees: (i) the long-studied system of bumblebees (Bombus spp.) associated with nine primarily northern species of Antirrhinum; and (ii) a newly proposed pollinator system involving other large bees associated with seven species primarily distributed in southern Mediterranean areas. © 2017 German Botanical Society and The Royal Botanical Society of the Netherlands.

  8. Auxiliary partial liver transplantation

    NARCIS (Netherlands)

    C.B. Reuvers (Cornelis Bastiaan)

    1986-01-01

    textabstractIn this thesis studies on auxiliary partial liver transplantation in the dog and the pig are reported. The motive to perform this study was the fact that patients with acute hepatic failure or end-stage chronic liver disease are often considered to form too great a risk for successful

  9. Partial Remission Definition

    DEFF Research Database (Denmark)

    Andersen, Marie Louise Max; Hougaard, Philip; Pörksen, Sven

    2014-01-01

    OBJECTIVE: To validate the partial remission (PR) definition based on insulin dose-adjusted HbA1c (IDAA1c). SUBJECTS AND METHODS: The IDAA1c was developed using data in 251 children from the European Hvidoere cohort. For validation, 129 children from a Danish cohort were followed from the onset...

  10. Fundamental partial compositeness

    DEFF Research Database (Denmark)

    Sannino, Francesco; Strumia, Alessandro; Tesi, Andrea

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Unde...

  11. Honesty in partial logic

    NARCIS (Netherlands)

    W. van der Hoek (Wiebe); J.O.M. Jaspars; E. Thijsse

    1995-01-01

    textabstractWe propose an epistemic logic in which knowledge is fully introspective and implies truth, although truth need not imply epistemic possibility. The logic is presented in sequential format and is interpreted in a natural class of partial models, called balloon models. We examine the

  12. Algebraic partial Boolean algebras

    International Nuclear Information System (INIS)

    Smith, Derek

    2003-01-01

    Partial Boolean algebras, first studied by Kochen and Specker in the 1960s, provide the structure for Bell-Kochen-Specker theorems which deny the existence of non-contextual hidden variable theories. In this paper, we study partial Boolean algebras which are 'algebraic' in the sense that their elements have coordinates in an algebraic number field. Several of these algebras have been discussed recently in a debate on the validity of Bell-Kochen-Specker theorems in the context of finite precision measurements. The main result of this paper is that every algebraic finitely-generated partial Boolean algebra B(T) is finite when the underlying space H is three-dimensional, answering a question of Kochen and showing that Conway and Kochen's infinite algebraic partial Boolean algebra has minimum dimension. This result contrasts the existence of an infinite (non-algebraic) B(T) generated by eight elements in an abstract orthomodular lattice of height 3. We then initiate a study of higher-dimensional algebraic partial Boolean algebras. First, we describe a restriction on the determinants of the elements of B(T) that are generated by a given set T. We then show that when the generating set T consists of the rays spanning the minimal vectors in a real irreducible root lattice, B(T) is infinite just if that root lattice has an A 5 sublattice. Finally, we characterize the rays of B(T) when T consists of the rays spanning the minimal vectors of the root lattice E 8

  13. Area at risk and collateral circulation in a first acute myocardial infarction with occluded culprit artery. STEMI vs non-STEMI patients.

    Science.gov (United States)

    Figueras, Jaume; Otaegui, Imanol; Marti, Gerard; Domingo, Enric; Bañeras, Jordi; Barrabés, José A; Del Blanco, Bruno Garcia; Garcia-Dorado, David

    2018-05-15

    It is unclear why among patients with first acute myocardial infarction and an occluded culprit artery only some present ST segment elevation. In fact, there is no study that compares the angiographic area at risk and the collateral circulation in first NSTEMI vs STEMI patients. 205 patients admitted for myocardial infarction with occluded culprit artery were included, 132 STEMI and 73 NSTEMI. Demographic data, the area at risk determined by the BARI score and collateral supply by the Rentrop score from the 2 groups were compared. NSTEMI patients showed lower peak Tn I than STEMI in the overall group but also in the 3 subsets with different culprit arteries (p collaterals (Rentrop score ≥ 2, 1.82 vs 0.41, p collateral blood supply than STEMI patients in each of the 3 main culprit arteries. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Transcatheter closure of a small atrial septal defect with an Amplatzer™ patent foramen ovale occluder in a working dog with cyanosis and exercise intolerance at high altitude.

    Science.gov (United States)

    Shelden, A; Wesselowski, S; Gordon, S G; Saunders, A B

    2017-12-01

    A 6.5-year-old male Border Collie presented for transcatheter closure of an atrial septal defect due to exercise intolerance and cyanosis while working and training at altitude. A small, left-to-right shunting secundum atrial septal defect was confirmed with no evidence of significant right-sided volume overload. Pulmonary hypertension with subsequent right-to-left interatrial shunting occurring during exercise at high altitude was suspected and prompted the closure of the defect due to the dog's continued athletic requirements. The anatomy of the defect prompted use of a patent foramen ovale occluder rather than an atrial septal defect occluder, which was deployed using a combination of fluoroscopic and transesophageal echocardiographic guidance. The owner did not report continued exercise intolerance or cyanosis and the dog's lifestyle and residence at altitude was unchanged. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Bleeding Duodenal Varices Successfully Treated with Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO) Assisted by CT During Arterial Portography

    International Nuclear Information System (INIS)

    Tsurusaki, Masakatsu; Sugimoto, Koji; Matsumoto, Shinichi; Izaki, Kenta; Fukuda, Tetsuya; Akasaka, Yoshinobu; Fujii, Masahiko; Hirota, Shozo; Sugimura, Kazuro

    2006-01-01

    A 60-year-old woman with massive hemorrhage from duodenal varices was transferred to our hospital for the purpose of transcatheter intervention. Although digital subtraction arterial portography could not depict the entire pathway of collateral circulation, the efferent route of the duodenal varices was clearly demonstrated on subsequent CT during arterial portography. Balloon-occluded retrograde transvenous obliteration (B-RTO) of the varices was performed via the efferent vein and achieved complete thrombosis of the varices

  16. Dual Balloon-Occluded Retrograde Transvenous Obliteration of Gastric Varix Draining into the Left Adrenal Vein and Left Inferior Phrenic Vein

    International Nuclear Information System (INIS)

    Nishida, Norifumi; Ninoi, Teruhisa; Kitayama, Toshiaki; Yamamoto, Akira; Sakai, Yukimasa; Sato, Kimihiko; Hamuro, Masao; Nakamura, Kenji; Inoue, Yuichi; Yamada, Ryusaku

    2004-01-01

    A 66-year-old woman with a gastric varix, draining into a dilated left adrenal vein and a left inferior phrenic vein, was treated with dual balloon-occluded retrograde transvenous obliteration (B-RTO). Under balloon occlusion of the left adrenal vein and the left inferior phrenic vein, retrograde injection of a sclerosant (5% ethanolamine oleate) into the gastric varix was performed. Two weeks later, disappearance of flow in the gastric varix was confirmed on endoscopic ultrasound examination

  17. Impact of National Clinical Guideline Recommendations for Revascularization of Persistently Occluded Infarct-Related Arteries on Clinical Practice in the United States

    Science.gov (United States)

    Deyell, Marc W.; Buller, Christopher E.; Miller, Louis H.; Wang, Tracy Y.; Dai, David; Lamas, Gervasio A.; Srinivas, Vankeepuram S.; Hochman, Judith S.

    2013-01-01

    Background The Occluded Artery Trial (OAT) was a large, randomized controlled trial published in 2006 that demonstrated no benefit to routine percutaneous coronary intervention (PCI) of persistently totally occluded infarct-related arteries (IRA) identified a minimum of 24 hours (on calendar days 3–28) after myocardial infarction (MI). The purpose of this study was to determine the impact of OAT results and consequent change in guideline recommendations for PCI for treatment of persistently occluded IRAs. Methods We identified all patients enrolled in the CathPCI Registry, from 2005 to 2008, undergoing catheterization more than 24 hours after MI with a totally occluded native coronary artery and no major OAT exclusion criteria. We examined trends in monthly rates of PCI for occlusions after OAT publication and after guideline revisions. Because reporting of diagnostic catheterizations was not mandatory, we examined trends among hospitals in the highest quartile for reporting of diagnostic procedures. Results A total of 28 780 patient visits from 896 hospitals were included. Overall, we found no significant decline in the adjusted monthly rate of PCI of occlusions after publication of OAT (odds ratio [OR], 0.997; 95% confidence interval [CI], 0.989–1.006) or after guideline revisions (OR, 1.007; 95% CI, 0.992–1.022). Among hospitals consistently reporting diagnostic catheterizations, there was no significant decline after OAT publication (OR, 1.018; 95% CI, 0.995–1.042), and there was a trend toward decline after guideline revisions (OR, 0.963; 95% CI, 0.920–1.000). Conclusion These findings suggest that the results of OAT and consequent guideline revisions have not, to date, been fully incorporated into clinical practice in a large cross-section of hospitals in the United States. PMID:21747002

  18. Balloon-occluded retrograde transvenous obliteration of gastric varix draining via the left inferior phrenic vein into the left hepatic vein

    International Nuclear Information System (INIS)

    Ibukuro, Kenji; Mori, Koichi; Tsukiyama, Toshitaka; Inoue, Yoshihiro; Iwamoto, Yukako; Tagawa, Kazumi

    1999-01-01

    We encountered a patient with gastric varix draining not via the usual left suprarenal vein but via the left inferior phrenic vein joining the left hepatic vein. Transfemoral balloon-occluded retrograde transvenous obliteration (BRTO) of the varix was performed under balloon occlusion of the left inferior phrenic vein via the left hepatic vein and retrograde injection of the sclerosing agent (5% of ethanolamine oleate) into the gastric varix. Disappearance of the gastric varix was confirmed on endoscopic examination 2 months later.

  19. Rhythmic neural activity indicates the contribution of attention and memory to the processing of occluded movements in 10-month-old infants.

    Science.gov (United States)

    Bache, Cathleen; Kopp, Franziska; Springer, Anne; Stadler, Waltraud; Lindenberger, Ulman; Werkle-Bergner, Markus

    2015-11-01

    Infants possess the remarkable capacity to perceive occluded movements as ongoing and coherent. Little is known about the neural mechanisms that enable internal representation of conspecifics' and inanimate objects' movements during visual occlusion. In this study, 10-month-old infants watched briefly occluded human and object movements. Prior to occlusion, continuous and distorted versions of the movement were shown. EEG recordings were used to assess neural activity assumed to relate to processes of attention (occipital alpha), memory (frontal theta), and sensorimotor simulation (central alpha) before, during, and after occlusion. Oscillatory activity was analyzed using an individualized data approach taking idiosyncrasies into account. Results for occipital alpha were consistent with infants' preference for attending to social stimuli. Furthermore, frontal theta activity was more pronounced when tracking distorted as opposed to continuous movement, and when maintaining object as opposed to human movement. Central alpha did not discriminate between experimental conditions. In sum, we conclude that observing occluded movements recruits processes of attention and memory which are modulated by stimulus and movement properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Partially composite Higgs models

    DEFF Research Database (Denmark)

    Alanne, Tommi; Buarque Franzosi, Diogo; Frandsen, Mads T.

    2018-01-01

    We study the phenomenology of partially composite-Higgs models where electroweak symmetry breaking is dynamically induced, and the Higgs is a mixture of a composite and an elementary state. The models considered have explicit realizations in terms of gauge-Yukawa theories with new strongly...... interacting fermions coupled to elementary scalars and allow for a very SM-like Higgs state. We study constraints on their parameter spaces from vacuum stability and perturbativity as well as from LHC results and find that requiring vacuum stability up to the compositeness scale already imposes relevant...... constraints. A small part of parameter space around the classically conformal limit is stable up to the Planck scale. This is however already strongly disfavored by LHC results. in different limits, the models realize both (partially) composite-Higgs and (bosonic) technicolor models and a dynamical extension...

  1. Full Waveform Analysis for Long-Range 3D Imaging Laser Radar

    Directory of Open Access Journals (Sweden)

    Wallace AndrewM

    2010-01-01

    Full Text Available The new generation of 3D imaging systems based on laser radar (ladar offers significant advantages in defense and security applications. In particular, it is possible to retrieve 3D shape information directly from the scene and separate a target from background or foreground clutter by extracting a narrow depth range from the field of view by range gating, either in the sensor or by postprocessing. We discuss and demonstrate the applicability of full-waveform ladar to produce multilayer 3D imagery, in which each pixel produces a complex temporal response that describes the scene structure. Such complexity caused by multiple and distributed reflection arises in many relevant scenarios, for example in viewing partially occluded targets, through semitransparent materials (e.g., windows and through distributed reflective media such as foliage. We demonstrate our methodology on 3D image data acquired by a scanning time-of-flight system, developed in our own laboratories, which uses the time-correlated single-photon counting technique.

  2. Photogenic partial seizures.

    Science.gov (United States)

    Hennessy, M J; Binnie, C D

    2000-01-01

    To establish the incidence and symptoms of partial seizures in a cohort of patients investigated on account of known sensitivity to intermittent photic stimulation and/or precipitation of seizures by environmental visual stimuli such as television (TV) screens or computer monitors. We report 43 consecutive patients with epilepsy, who had exhibited a significant EEG photoparoxysmal response or who had seizures precipitated by environmental visual stimuli and underwent detailed assessment of their photosensitivity in the EEG laboratory, during which all were questioned concerning their ictal symptoms. All patients were considered on clinical grounds to have an idiopathic epilepsy syndrome. Twenty-eight (65%) patients reported visually precipitated attacks occurring initially with maintained consciousness, in some instances evolving to a period of confusion or to a secondarily generalized seizure. Visual symptoms were most commonly reported and included positive symptoms such as coloured circles or spots, but also blindness and subjective symptoms such as "eyes going funny." Other symptoms described included nonspecific cephalic sensations, deja-vu, auditory hallucinations, nausea, and vomiting. No patient reported any clear spontaneous partial seizures, and there were no grounds for supposing that any had partial epilepsy excepting the ictal phenomenology of some or all of the visually induced attacks. These findings provide clinical support for the physiological studies that indicate that the trigger mechanism for human photosensitivity involves binocularly innervated cells located in the visual cortex. Thus the visual cortex is the seat of the primary epileptogenic process, and the photically triggered discharges and seizures may be regarded as partial with secondary generalization.

  3. Arthroscopic partial medial meniscectomy

    Directory of Open Access Journals (Sweden)

    Dašić Žarko

    2011-01-01

    Full Text Available Background/Aim. Meniscal injuries are common in professional or recreational sports as well as in daily activities. If meniscal lesions lead to physical impairment they usually require surgical treatment. Arthroscopic treatment of meniscal injuries is one of the most often performed orthopedic operative procedures. Methods. The study analyzed the results of arthroscopic partial medial meniscectomy in 213 patients in a 24-month period, from 2006, to 2008. Results. In our series of arthroscopically treated medial meniscus tears we noted 78 (36.62% vertical complete bucket handle lesions, 19 (8.92% vertical incomplete lesions, 18 (8.45% longitudinal tears, 35 (16.43% oblique tears, 18 (8.45% complex degenerative lesions, 17 (7.98% radial lesions and 28 (13.14% horisontal lesions. Mean preoperative International Knee Documentation Committee (IKDC score was 49.81%, 1 month after the arthroscopic partial medial meniscectomy the mean IKDC score was 84.08%, and 6 months after mean IKDC score was 90.36%. Six months after the procedure 197 (92.49% of patients had good or excellent subjective postoperative clinical outcomes, while 14 (6.57% patients subjectively did not notice a significant improvement after the intervention, and 2 (0.93% patients had no subjective improvement after the partial medial meniscectomy at all. Conclusion. Arthroscopic partial medial meniscetomy is minimally invasive diagnostic and therapeutic procedure and in well selected cases is a method of choice for treatment of medial meniscus injuries when repair techniques are not a viable option. It has small rate of complications, low morbidity and fast rehabilitation.

  4. Hierarchical partial order ranking

    International Nuclear Information System (INIS)

    Carlsen, Lars

    2008-01-01

    Assessing the potential impact on environmental and human health from the production and use of chemicals or from polluted sites involves a multi-criteria evaluation scheme. A priori several parameters are to address, e.g., production tonnage, specific release scenarios, geographical and site-specific factors in addition to various substance dependent parameters. Further socio-economic factors may be taken into consideration. The number of parameters to be included may well appear to be prohibitive for developing a sensible model. The study introduces hierarchical partial order ranking (HPOR) that remedies this problem. By HPOR the original parameters are initially grouped based on their mutual connection and a set of meta-descriptors is derived representing the ranking corresponding to the single groups of descriptors, respectively. A second partial order ranking is carried out based on the meta-descriptors, the final ranking being disclosed though average ranks. An illustrative example on the prioritisation of polluted sites is given. - Hierarchical partial order ranking of polluted sites has been developed for prioritization based on a large number of parameters

  5. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  6. Development of Thrombus in a Systemic Vein after Balloon-Occluded Retrograde Transvenous Obliteration of Gastric Varices

    International Nuclear Information System (INIS)

    Yoshimatsu, Rika; Yamagami, Takuji; Tanaka, Osamu; Miura, Hiroshi; Nishimura, Tsunehiko; Okuda, Kotaro; Hashiba, Mitsuoki

    2012-01-01

    To retrospectively evaluate the frequency and risk factors for developing thrombus in a systemic vein such as the infrarenal inferior vena cava or the iliac vein, in which a balloon-occluded retrograde transvenous obliteration (B-RTO) catheter was indwelled. Forty-nine patients who underwent B-RTO for gastric varices were included in this study. The B-RTO procedure was performed from the right femoral vein, and the B-RTO catheter was retained overnight in all patients. Pre- and post-procedural CT scans were retrospectively compared in order to evaluate the development of thrombus in the systemic vein in which the catheter was indwelled. Additionally, several variables were analyzed to assess risk factors for thrombus in a systemic vein. In all 49 patients (100%), B-RTO was technically successful, and in 46 patients (94%), complete thrombosis of the gastric varices was achieved. In 6 patients (12%), thrombus developed in the infrarenal inferior vena cava or the right common-external iliac vein. All thrombi lay longitudinally on the right side of the inferior vena cava or the right iliac vein. One of the aforementioned 6 patients required anticoagulation therapy. No symptoms suggestive of pulmonary embolism were observed. Prothrombin time-international normalized ratio and the addition of 5% ethanolamine oleate iopamidol, on the second day, were related to the development of thrombus. Development of a thrombus in a systemic vein such as the inferior vena cava or iliac vein, caused by indwelling of the B-RTO catheter, is relatively frequent. Physicians should be aware of the possibility of pulmonary embolism due to iliocaval thrombosis.

  7. Clinical outcomes and prognostic factors associated with survival after balloon-occluded retrograde transvenous obliteration of gastric varices

    International Nuclear Information System (INIS)

    Uozumi, Shojiro; Baba, Toshiyuki; Sai, Syouei; Seino, Noritaka; Hashimoto, Toshi; Honda, Minoru; Gokan, Takehiko; Imawari, Michio

    2011-01-01

    We evaluated clinical outcomes and prognostic factors associated with survival after balloon-occluded retrograde transvenous obliteration (B-RTO) of gastric varices in patients with portal hypertension. Of 50 patients with gastric varices who underwent B-RTO, 46 (94.0%) patients in whom B-RTO was technically successful were reviewed retrospectively. Gastric and esophageal varices after B-RTO were evaluated by contrast-enhanced computer tomography and endoscopy, respectively. Liver function parameters and Child-Pugh scores were estimated before and at 1 year after B-RTO. The cumulative survival rate was calculated, and univariate and multivariate analyses were used to assess the prognostic factors. No major complications occurred in any of the patients following B-RTO and no recurrence or bleeding of gastric varices was noted. Of the 42 patients who were followed up for the progression of esophageal varices, 13 (31.0%) had worsened varices and of these, 6 (14.3%) showed bleeding. Prothrombin activity had significantly improved at 1 year after B-RTO, although there were no changes in other liver function parameters. The overall cumulative survival rates at 1, 3, and 5 years after B-RTO were 91.6%, 70.9%, and 53.6%, respectively. Multivariate analysis identified the occurrence of advanced hepatocellular carcinoma (HCC) during the observation period as a prognostic factor for survival (hazard ratio=4.1497, 95% CI=1.32314-13.0319, P=0.0148). B-RTO of gastric varices is an effective treatment ensuring lower recurrence and bleeding rates; however, these patients require careful observation for progression of esophageal varices. The management of HCC is crucial for achieving long-term survival after B-RTO. (author)

  8. Balloon-occluded retrograde transvenous obliteration versus endoscopic injection sclerotherapy for isolated gastric varices: a comparative study.

    Science.gov (United States)

    Emori, Keigo; Toyonaga, Atsushi; Oho, Kazuhiko; Kumamoto, Masafumi; Haruta, Tsuyoshi; Inoue, Hiroto; Morita, Yukihiko; Mitsuyama, Keiichi; Tsuruta, Osamu; Sata, Michio

    2014-01-01

    Isolated gastric varices (IGV) have a lower risk of bleeding than esophageal varices, however IGV bleeding is associated with a higher mortality than bleeding of esophageal varices. In recent years, two widely used treatments for IGV have been balloon-occluded retrograde transvenous obliteration (B-RTO) and endoscopic injection sclerotherapy (EIS) using cyanoacrylate or ethanolamine oleate (EO). This study compared these two treatment methods for IGV. The subjects were 112 patients who were treated at our hospital for IGV bleeding between October 1990 and December 2003. Forty-nine (49) patients were treated with B-RTO and 63 patients with EIS. These two patient groups were compared as regards content of treatment, post-treatment incidence of variceal bleeding, incidence of IGV rebleeding, survival rate, cause of death, and complications. Multivariate analysis was performed on post-treatment variceal bleeding and survival. Although EO was used in higher amounts in the B-RTO group than in the EIS group, the B-RTO group had a significantly lower number of treatment sessions and a significantly shorter treatment period (pIGV rebleeding after treatment than the B-RTO group. Treatment method was the only independent prognostic factor of IGV bleeding after treatment (p=0.024). The two groups did not differ significantly in the percentage of patients with aggravated esophageal varices after treatment. Bleeding from ectopic varices was not observed in any patient. There was no significant difference in survival by treatment method. The presence of hepatocellular carcinoma was the only independent prognostic factor for survival (p=0.003). It is concluded that B-RTO was more effective than EIS in the eradication of IGV and prevention of IGV recurrence and rebleeding.

  9. Patent ductus arteriosus occlusion in small dogs utilizing a low profile Amplatz® canine duct occluder prototype.

    Science.gov (United States)

    Stauthammer, Christopher D; Olson, Janet; Leeder, Damon; Hohnadel, Kristin; Hanson, Melissa; Tobias, Anthony H

    2015-09-01

    To develop procedural methodology and assess the safety, utility and effectiveness of a low profile Amplatz(®) canine duct occluder (ACDO) prototype in dogs deemed too small to undergo ductal occlusion with the commercially-available ACDO device. Twenty-one dogs with left-to-right shunting patent ductus arteriosus (PDA). Dogs were ≥1.5 kg but considered too small to accommodate a 6 Fr catheter or 4 Fr sheath within the femoral artery. Prospective canine study using a low profile ACDO prototype delivered through a 4 Fr catheter via a femoral arterial approach. Procedural methods, fluoroscopy time, perioperative complications, and residual ductal flow were evaluated, and angiographic ductal morphology and dimensions were tabulated. All 21 dogs underwent successful ductal occlusion using the prototype device, 4 Fr catheter, and right femoral artery approach. No perioperative complications or device embolization occurred. The median minimal ductal diameter was 1.9 mm (range, 0.4-3.4), and the median device size deployed was 4 mm (range, 3-6). Complete ductal occlusion was noted in 17 dogs (81%) on post-deployment angiography. Twenty dogs (95%) had no residual flow on echocardiography performed the following day. In the 17 dogs (81%) that returned for a long-term (≥3months) follow-up evaluation, all had complete ductal occlusion based on echocardiography. The low profile ACDO prototype is a safe and effective method of PDA occlusion in the small dog. The deployment procedure appears of similar technical difficulty to the commercially available ACDO. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Balloon-occluded retrograde transvenous obliteration for gastric variceal bleeding: its feasibility compared with transjugular intrahepatic portosystemic shunt

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Ho; Yoon, Chang Jin; Park, Jae Hyung; Chung, Jin Wook; Kwon, Jong Won [Seoul Natioonal University College of Medicine, Seoul (Korea, Republic of); Choi, Guk Myung [Cheju National University College of Medicine, Jeju (Korea, Republic of)

    2003-06-01

    To assess the feasibility of balloon-occluded retrograde transvenous obliteration (BRTO) in active gastric variceal bleeding, and to compare the findings with those of transjugular intrahepatic portosystemic shunt (TIPS). Twenty-one patients with active gastric variceal bleeding due to liver cirrhosis were referred for radiological intervention. In 15 patients, contrast-enhanced CT scans demonstrated gastrorenal shunt, and the remaining six (Group 1) underwent TIPS. Seven of the 15 with gastrorenal shunt (Group 2) were also treated with TIPS, and the other eight (Group 3) underwent BRTO. All patients were followed up for 6 to 21 (mean, 14.4) months. For statistical inter-group comparison of immediate hemostasis, rebleeding and encephalopathy, Fisher's exact test was used. Changes in the Child-Pugh score before and after each procedure in each group were statistically analyzed by means of Wilcoxon's signed rank test. One patient in Group 1 died of sepsis, acute respiratory distress syndrome, and persistent bleeding three days after TIPS, while the remaining 20 survived the procedure with immediate hemostasis. Hepatic encephalopathy developed in four patients (one in Group 1, three in Group 2, and none in Group 3); one, in Group 2, died while in an hepatic coma 19 months after TIPS. Rebleeding occurred in one patient, also in Group 2. Except for transient fever in two Group-3 patients, no procedure-related complication occurred. In terms of immediate hemostasis, rebleeding and encephalopathy, there were no statistically significant differences between the groups (p > 0.05). In Group 3, the Child-Pugh score showed a significant decrease after the procedure (p = 0.02). BRTO can effectively control active gastric variceal bleeding, and because of immediate hemostasis, the absence of rebleeding, and improved liver function, is a good alternative to TIPS in patients in whom such bleeding, accompanied by gastrorenal shunt, occurs.

  11. Balloon-occluded retrograde transvenous obliteration for gastric variceal bleeding: its feasibility compared with transjugular intrahepatic portosystemic shunt

    International Nuclear Information System (INIS)

    Choi, Young Ho; Yoon, Chang Jin; Park, Jae Hyung; Chung, Jin Wook; Kwon, Jong Won; Choi, Guk Myung

    2003-01-01

    To assess the feasibility of balloon-occluded retrograde transvenous obliteration (BRTO) in active gastric variceal bleeding, and to compare the findings with those of transjugular intrahepatic portosystemic shunt (TIPS). Twenty-one patients with active gastric variceal bleeding due to liver cirrhosis were referred for radiological intervention. In 15 patients, contrast-enhanced CT scans demonstrated gastrorenal shunt, and the remaining six (Group 1) underwent TIPS. Seven of the 15 with gastrorenal shunt (Group 2) were also treated with TIPS, and the other eight (Group 3) underwent BRTO. All patients were followed up for 6 to 21 (mean, 14.4) months. For statistical inter-group comparison of immediate hemostasis, rebleeding and encephalopathy, Fisher's exact test was used. Changes in the Child-Pugh score before and after each procedure in each group were statistically analyzed by means of Wilcoxon's signed rank test. One patient in Group 1 died of sepsis, acute respiratory distress syndrome, and persistent bleeding three days after TIPS, while the remaining 20 survived the procedure with immediate hemostasis. Hepatic encephalopathy developed in four patients (one in Group 1, three in Group 2, and none in Group 3); one, in Group 2, died while in an hepatic coma 19 months after TIPS. Rebleeding occurred in one patient, also in Group 2. Except for transient fever in two Group-3 patients, no procedure-related complication occurred. In terms of immediate hemostasis, rebleeding and encephalopathy, there were no statistically significant differences between the groups (p > 0.05). In Group 3, the Child-Pugh score showed a significant decrease after the procedure (p = 0.02). BRTO can effectively control active gastric variceal bleeding, and because of immediate hemostasis, the absence of rebleeding, and improved liver function, is a good alternative to TIPS in patients in whom such bleeding, accompanied by gastrorenal shunt, occurs

  12. Use of a percutaneously controlled hydraulic occluder for treatment of refractory urinary incontinence in three female cats.

    Science.gov (United States)

    Wilson, Kendall E; Berent, Allyson C; Weisse, Chick W

    2016-03-01

    CASE DESCRIPTION 3 cats were referred for evaluation of chronic urinary incontinence. CLINICAL FINDINGS A presumptive diagnosis of urethral sphincter mechanism incompetence (USMI) was made in all 3 cats. Preoperatively, incontinence was mild in 1 cat (incontinence during sleep) and moderate to severe (incontinence while awake and at rest) in 2. Structural abnormalities noted during cystoscopy included urethrovestibular junction stenosis (n = 1), vaginal stenosis (1), short urethra (1), and intrapelvic bladder (1). TREATMENT AND OUTCOME All 3 cats were treated by means of implantation of an inflatable silicone hydraulic occluder (HO) via a ventral midline celiotomy. Immediately prior to HO implantation, patients underwent cystoscopy to detect any anatomic abnormalities and confirm the absence of ureteral ectopia. Following surgery, all 3 patients attained complete continence, needing 0 or 1 inflation of the device. Complications included cystoscopy-associated urethral tear (n = 1), constipation (1), stranguria (1), hematuria (2), and urinary tract infection (2). Device explantation was performed 14 weeks after surgery in 1 cat because of postoperative constipation. Constipation persisted and urinary incontinence recurred but was markedly improved following device removal in this cat (leakage of urine only when sleeping at follow-up 29 months after surgery [26 months after device explantation]). At the time of last follow-up, 2 of the 3 cats remained fully continent approximately 3 and 6 years after device implantation. CLINICAL RELEVANCE Findings suggested that implantation of an HO may be a safe and effective long-term treatment for some cats with USMI. Further studies are necessary to evaluate the potential for treatment-related complications and the long-term outcome.

  13. Techniques for trans-catheter retrieval of embolized Nit-Occlud® PDA-R and ASD-R devices.

    Science.gov (United States)

    Sinha, Sanjay; Levi, Daniel; Peirone, Alejandro; Pedra, Carlos

    2018-02-15

    Nit-Occlud ® (atrial septal defect) ASD-R and (patent ductus arteriosus) PDA-R devices are used outside the United States for percutaneous closure of the patent ductus arteriosus and atrial septal defects. When embolization occurs, these devices have been difficult to retrieve. Bench simulations of retrieval of PDA-R and ASD-R devices were performed in a vascular model. Retrieval of each device was attempted using snare techniques or with bioptome forceps with a range of devices. The same devices were then intentionally embolized in an animal model. Retrieval methods were systematically tested in a range of sheath sizes, and graded in terms of difficulty and retrieval time. Devices that were grasped by the bioptome in the center of the proximal part of the devices were easily retrieved in both models. Bench studies determined the minimum sheath sizes needed for retrieval of each device with this method. In general sheathes two french sizes greater than the delivery sheath were successful with this technique. Three out of the four PDA-R devices were successfully retrieved in vivo. Two were retrieved by grasping the middle of the PA end of the PDA-R device with a Maslanka bioptome and one small PDA-R device was retrieved using a 10 mm Snare. Four of the five ASD-R devices were retrieved successfully grasping the right atrial ASD-R disc or by passing a wire through the device and snaring this loop. For ASD-R 28 and 30 mm devices, a double bioptome technique was needed to retrieve the device. ASD-R and PDA-R devices can be successfully retrieved in the catheterization lab. It is critical to grab the center portion of the right atrial disc of the ASD-R device or pulmonary portion of the PDA-R device and to use adequately sized sheathes. © 2018 Wiley Periodicals, Inc.

  14. [Effects of removable partial dentures on the quality of life in people with shortened dental arches].

    Science.gov (United States)

    Armellini, D B; Heydecke, G; Witter, D J; Creugers, N H J

    2009-12-01

    In order to assess the enhanced value of removable partial dentures on the quality of life, patients at 2 university clinics were screened for the presence of complete or shortened dental arches. Those selected were assigned to 1 of 5 subgroups: 1) a shortened dental arch with all frontal teeth, 2) a shortened dental arch with one or more frontal diastemas, 3) a shortened dental arch with all frontal teeth, restored by a removable partial denture, 4) a shortened dental arch and several diastemas, restored by a removable partial denture, 5) a complete dental arch. The participants completed the Oral Health Impact Profile (OHIP-49) and the Short Form Health Survey (SF-36). Clinical data recorded were: whether any teeth were missing and if so which, whether or not these had been replaced by a removable partial denture, and the number of occluding pairs of (pre)molars. The results revealed that a shortenend dental arch has a certain impact on the quality of life. However, the participants only experienced benefits from a removable partial denture if the denture also replaced frontal teeth.

  15. Partial thyroid arterial embolization for the treatment of hyperthyroidism

    International Nuclear Information System (INIS)

    Brzozowski, Krzysztof; Piasecki, Piotr; Zięcina, Piotr; Frankowska, Emilia; Jaroszuk, Andrzej; Kamiński, Grzegorz; Bogusławska-Walecka, Romana

    2012-01-01

    Background: Hyperactive thyroid gland in patients that are unable to tolerate or accept standard therapy is a common clinical problem. Aim of the study was to evaluate effectiveness of partial thyroid arterial embolization in patients with hyperthyroidism. Material/methods: From May 2004 to November 2005 partial thyroid gland embolization was performed in 15 patients. Mean thyroid gland volume was 162 ml. Embolization of one to three thyriod arteries was performed with the mixture of Histoacryl and Lipiodol. Selective angiography was performed after embolization to ensure that the targeted arteries were completely occluded. Follow-up study covered 12 patients. Results: The embolization procedure was well tolerated by all patients. Three days after embolization fT3 and fT4 levels were higher than before the procedure. Further laboratory tests showed quick reversal to near-normal or normal levels of thyroid hormones. 12 weeks follow-up showed: normal serum levels of fT3, fT4 and TSH in 9 of 12 patients (75%), hyperthyroidism in 3 of 12 patients (25%), goiter volume reduction of approximately 32% of its original volume (from 13 to 76.3%), mean thyroid gland volume of 94 ml. One year after embolization 7 of 12 patients required thyreostatic drugs. At two and four years follow-up thyreostatics doses were significantly lower and thyroid tissue was fibrotic. Conclusions: Based on our results the treatment of the thyroid gland goiters using arterial thyroid gland partial embolization may be offered as an effective alternative for patients who will not or cannot accept standard therapy.

  16. SPAM-assisted partial volume correction algorithm for PET

    International Nuclear Information System (INIS)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul

    2000-01-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38±6%, while those of hippocampus and amygdala by 4±3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images

  17. SPAM-assisted partial volume correction algorithm for PET

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2000-07-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38{+-}6%, while those of hippocampus and amygdala by 4{+-}3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images.

  18. Partial (focal) seizure

    Science.gov (United States)

    ... Patient Instructions Epilepsy - what to ask your doctor - adult Epilepsy - what to ask your doctor - child Images Central nervous system and peripheral nervous system References Abou-Khalil BW, ...

  19. [Treatment of removable partial dentures. 2. Causes and consequences of a reduced occlusal system].

    Science.gov (United States)

    Witter, D J; Barèl, J C; de Baat, C; Keltjens, H M A M; Creugers, N H J

    2011-01-01

    The occlusal system is part of the orofacial system and consists of the maxillary and mandibular alveolar ridge and teeth which are occluding or not or the removable denture teeth. The most prevalent causes of loss of teeth are insufficient oral self care or inadequate professional oral healthcare service. A reduced dentition can be described in terms of diastemas in the anterior region and number of occluding pairs of (pre)molars, differentiated as interrupted or shortened dental arches. Characteristic of a healthy functional occlusal system are the absence of pathology and the possibility to practice all oral functions without inconvenience. The consequences of a reduced occlusal system may be overload and/or migration of teeth, mandibular instability, and impaired esthetics and chewing function. Morphological and functional alterations can be considered to be adaptations to changed situations or to be pathological. The distinction between adaptation and pathology cannot be sharply defined. If prosthetic replacement of teeth is needed, the trend is to avoid removable partial dentures.

  20. STA-MCA Bypass as a “Bridge” to Pituitary Surgery in a Patient with an Adenoma Occluding the Internal Carotid Artery: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Luigi A. Lanterna

    2015-01-01

    Full Text Available Occlusion of the intracranial internal carotid artery (ICA by a pituitary adenoma with resulting cerebral ischemia is a very rare but devastating occurrence. The authors present a case in which a condition of symptomatic ICA occlusion due to a giant pituitary adenoma was successfully treated using a preliminary extraintracranial bypass as a “bridge” to the tumor removal. A 52-year-old patient presented with a minor stroke followed by pressure-dependent transient ischemic attacks consistent with a condition of hypoperfusion. MR imaging and a digital subtraction angiography revealed a pituitary adenoma occluding the ICA on the right side. He underwent a superficial temporal artery to middle cerebral artery (STA-MCA bypass with the aim of revascularizing the ischemic hemisphere and reducing the risk of perioperative stroke or stroke evolution. The patient was subsequently operated on to remove the adenoma through a transsphenoidal approach. The postoperative course was uneventful and the patient has suffered no further ischemic events. When there are no emergency indications to decompress the optical pathways but the patient is at risk of impending stroke because of ICA occlusion, a two-step strategy consisting of a bypass and subsequent removal of the pituitary adenoma may be a valuable option.

  1. Partially ordered algebraic systems

    CERN Document Server

    Fuchs, Laszlo

    2011-01-01

    Originally published in an important series of books on pure and applied mathematics, this monograph by a distinguished mathematician explores a high-level area in algebra. It constitutes the first systematic summary of research concerning partially ordered groups, semigroups, rings, and fields. The self-contained treatment features numerous problems, complete proofs, a detailed bibliography, and indexes. It presumes some knowledge of abstract algebra, providing necessary background and references where appropriate. This inexpensive edition of a hard-to-find systematic survey will fill a gap i

  2. Infinite partial summations

    International Nuclear Information System (INIS)

    Sprung, D.W.L.

    1975-01-01

    This paper is a brief review of those aspects of the effective interaction problem that can be grouped under the heading of infinite partial summations of the perturbation series. After a brief mention of the classic examples of infinite summations, the author turns to the effective interaction problem for two extra core particles. Their direct interaction is summed to produce the G matrix, while their indirect interaction through the core is summed in a variety of ways under the heading of core polarization. (orig./WL) [de

  3. On universal partial words

    OpenAIRE

    Chen, Herman Z. Q.; Kitaev, Sergey; Mütze, Torsten; Sun, Brian Y.

    2016-01-01

    A universal word for a finite alphabet $A$ and some integer $n\\geq 1$ is a word over $A$ such that every word in $A^n$ appears exactly once as a subword (cyclically or linearly). It is well-known and easy to prove that universal words exist for any $A$ and $n$. In this work we initiate the systematic study of universal partial words. These are words that in addition to the letters from $A$ may contain an arbitrary number of occurrences of a special `joker' symbol $\\Diamond\

  4. Partial differential equations

    CERN Document Server

    Agranovich, M S

    2002-01-01

    Mark Vishik's Partial Differential Equations seminar held at Moscow State University was one of the world's leading seminars in PDEs for over 40 years. This book celebrates Vishik's eightieth birthday. It comprises new results and survey papers written by many renowned specialists who actively participated over the years in Vishik's seminars. Contributions include original developments and methods in PDEs and related fields, such as mathematical physics, tomography, and symplectic geometry. Papers discuss linear and nonlinear equations, particularly linear elliptic problems in angles and gener

  5. Partial differential equations

    CERN Document Server

    Levine, Harold

    1997-01-01

    The subject matter, partial differential equations (PDEs), has a long history (dating from the 18th century) and an active contemporary phase. An early phase (with a separate focus on taut string vibrations and heat flow through solid bodies) stimulated developments of great importance for mathematical analysis, such as a wider concept of functions and integration and the existence of trigonometric or Fourier series representations. The direct relevance of PDEs to all manner of mathematical, physical and technical problems continues. This book presents a reasonably broad introductory account of the subject, with due regard for analytical detail, applications and historical matters.

  6. Partial differential equations

    CERN Document Server

    Sloan, D; Süli, E

    2001-01-01

    /homepage/sac/cam/na2000/index.html7-Volume Set now available at special set price ! Over the second half of the 20th century the subject area loosely referred to as numerical analysis of partial differential equations (PDEs) has undergone unprecedented development. At its practical end, the vigorous growth and steady diversification of the field were stimulated by the demand for accurate and reliable tools for computational modelling in physical sciences and engineering, and by the rapid development of computer hardware and architecture. At the more theoretical end, the analytical insight in

  7. Elliptic partial differential equations

    CERN Document Server

    Han, Qing

    2011-01-01

    Elliptic Partial Differential Equations by Qing Han and FangHua Lin is one of the best textbooks I know. It is the perfect introduction to PDE. In 150 pages or so it covers an amazing amount of wonderful and extraordinary useful material. I have used it as a textbook at both graduate and undergraduate levels which is possible since it only requires very little background material yet it covers an enormous amount of material. In my opinion it is a must read for all interested in analysis and geometry, and for all of my own PhD students it is indeed just that. I cannot say enough good things abo

  8. Maxillofacial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Larheim, T.A. [Oslo Univ. (Norway). Dept. of Maxillofacial Radiology; Westesson, P.L. [Univ. of Rochester School of Medicine and Dentistry, NY (United States). Div. of Diagnostic and Interventional Radiology

    2006-07-01

    Maxillofacial imaging has evolved dramatically over the past two decades with development of new cross-sectional imaging techniques. Traditional maxillofacial imaging was based on plain films and dental imaging. However, today's advanced imaging techniques with CT and MRI have only been partially implemented for maxillofacial questions. This book bridges the gap between traditional maxillofacial imaging and advanced medical imaging. We have applied CT and MRI to a variety of maxillofacial cases and these are illustrated with high-quality images and multiple planes. A comprehensive chapter on imaging anatomy is also included. This book is useful for oral and maxillofacial radiologists, oral and maxillofacial surgeons, dentists, radiologists, plastic surgeons, head and neck surgeons, and others that work with severe maxillofacial disorders. (orig.)

  9. Unilateral removable partial dentures.

    Science.gov (United States)

    Goodall, W A; Greer, A C; Martin, N

    2017-01-27

    Removable partial dentures (RPDs) are widely used to replace missing teeth in order to restore both function and aesthetics for the partially dentate patient. Conventional RPD design is frequently bilateral and consists of a major connector that bridges both sides of the arch. Some patients cannot and will not tolerate such an extensive appliance. For these patients, bridgework may not be a predictable option and it is not always possible to provide implant-retained restorations. This article presents unilateral RPDs as a potential treatment modality for such patients and explores indications and contraindications for their use, including factors relating to patient history, clinical presentation and patient wishes. Through case examples, design, material and fabrication considerations will be discussed. While their use is not widespread, there are a number of patients who benefit from the provision of unilateral RPDs. They are a useful treatment to have in the clinician's armamentarium, but a highly-skilled dental team and a specific patient presentation is required in order for them to be a reasonable and predictable prosthetic option.

  10. Tutorial on Online Partial Evaluation

    Directory of Open Access Journals (Sweden)

    William R. Cook

    2011-09-01

    Full Text Available This paper is a short tutorial introduction to online partial evaluation. We show how to write a simple online partial evaluator for a simple, pure, first-order, functional programming language. In particular, we show that the partial evaluator can be derived as a variation on a compositionally defined interpreter. We demonstrate the use of the resulting partial evaluator for program optimization in the context of model-driven development.

  11. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML...

  12. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML of ...

  13. Applied partial differential equations

    CERN Document Server

    Logan, J David

    2004-01-01

    This primer on elementary partial differential equations presents the standard material usually covered in a one-semester, undergraduate course on boundary value problems and PDEs. What makes this book unique is that it is a brief treatment, yet it covers all the major ideas: the wave equation, the diffusion equation, the Laplace equation, and the advection equation on bounded and unbounded domains. Methods include eigenfunction expansions, integral transforms, and characteristics. Mathematical ideas are motivated from physical problems, and the exposition is presented in a concise style accessible to science and engineering students; emphasis is on motivation, concepts, methods, and interpretation, rather than formal theory. This second edition contains new and additional exercises, and it includes a new chapter on the applications of PDEs to biology: age structured models, pattern formation; epidemic wave fronts, and advection-diffusion processes. The student who reads through this book and solves many of t...

  14. Inductance loop and partial

    CERN Document Server

    Paul, Clayton R

    2010-01-01

    "Inductance is an unprecedented text, thoroughly discussing "loop" inductance as well as the increasingly important "partial" inductance. These concepts and their proper calculation are crucial in designing modern high-speed digital systems. World-renowned leader in electromagnetics Clayton Paul provides the knowledge and tools necessary to understand and calculate inductance." "With the present and increasing emphasis on high-speed digital systems and high-frequency analog systems, it is imperative that system designers develop an intimate understanding of the concepts and methods in this book. Inductance is a much-needed textbook designed for senior and graduate-level engineering students, as well as a hands-on guide for working engineers and professionals engaged in the design of high-speed digital and high-frequency analog systems."--Jacket.

  15. Fundamental partial compositeness

    CERN Document Server

    Sannino, Francesco

    2016-11-07

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough 'square root'. Furthermore, right-handed SM fermions have an SU(2)$_R$-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  16. Fundamental partial compositeness

    International Nuclear Information System (INIS)

    Sannino, Francesco; Strumia, Alessandro; Tesi, Andrea; Vigiani, Elena

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Under certain assumptions on the dynamics of the scalars, successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough ‘square root’. Furthermore, right-handed SM fermions have an SU(2)_R-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  17. Partial oxidation process

    International Nuclear Information System (INIS)

    Najjar, M.S.

    1987-01-01

    A process is described for the production of gaseous mixtures comprising H/sub 2/+CO by the partial oxidation of a fuel feedstock comprising a heavy liquid hydrocarbonaceous fuel having a nickel, iron, and vanadium-containing ash or petroleum coke having a nickel, iron, and vanadium-containing ash, or mixtures thereof. The feedstock includes a minimum of 0.5 wt. % of sulfur and the ash includes a minimum of 5.0 wt. % vanadium, a minimum of 0.5 ppm nickel, and a minimum of 0.5 ppm iron. The process comprises: (1) mixing together a copper-containing additive with the fuel feedstock; wherein the weight ratio of copper-containing additive to ash in the fuel feedstock is in the range of about 1.0-10.0, and there is at least 10 parts by weight of copper for each part by weight of vanadium; (2) reacting the mixture from (1) at a temperature in the range of 2200 0 F to 2900 0 F and a pressure in the range of about 5 to 250 atmospheres in a free-flow refactory lined partial oxidation reaction zone with a free-oxygen containing gas in the presence of a temperature moderator and in a reducing atmosphere to produce a hot raw effluent gas stream comprising H/sub 2/+CO and entrained molten slag; and where in the reaction zone and the copper-containing additive combines with at least a portion of the nickel and iron constituents and sulfur found in the feedstock to produce a liquid phase washing agent that collects and transports at least a portion of the vanadium-containing oxide laths and spinels and other ash components and refractory out of the reaction zone; and (3) separating nongaseous materials from the hot raw effluent gas stream

  18. Voice Quality After a Semi-Occluded Vocal Tract Exercise With a Ventilation Mask in Contemporary Commercial Singers: Acoustic Analysis and Self-Assessments.

    Science.gov (United States)

    Fantini, Marco; Succo, Giovanni; Crosetti, Erika; Borragán Torre, Alfonso; Demo, Roberto; Fussi, Franco

    2017-05-01

    The current study aimed at investigating the immediate effects of a semi-occluded vocal tract exercise with a ventilation mask in a group of contemporary commercial singers. A randomized controlled study was carried out. Thirty professional or semi-professional singers with no voice complaints were randomly divided into two groups on recruitment: an experimental group and a control group. The same warm-up exercise was performed by the experimental group with an occluded ventilation mask placed over the nose and the mouth and by the control group without the ventilation mask. Voice was recorded before and after the exercise. Acoustic and self-assessment analysis were accomplished. The acoustic parameters of the voice samples recorded before and after training were compared, as well as the parameters' variations between the experimental and the control group. Self-assessment results of the experimental and the control group were compared too. Significant changes after the warm-up exercise included jitter, shimmer, and singing power ratio (SPR) in the experimental group. No significant changes were recorded in the control group. Significant differences between the experimental and the control group were found for ΔShimmer and ΔSPR. Self-assessment analysis confirmed a significantly higher phonatory comfort and voice quality perception for the experimental group. The results of the present study support the immediate advantageous effects on singing voice of a semi-occluded vocal tract exercise with a ventilation mask in terms of acoustic quality, phonatory comfort, and voice quality perception in contemporary commercial singers. Long-term effects still remain to be studied. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  19. A parametric level-set method for partially discrete tomography

    NARCIS (Netherlands)

    A. Kadu (Ajinkya); T. van Leeuwen (Tristan); K.J. Batenburg (Joost)

    2017-01-01

    textabstractThis paper introduces a parametric level-set method for tomographic reconstruction of partially discrete images. Such images consist of a continuously varying background and an anomaly with a constant (known) grey-value. We express the geometry of the anomaly using a level-set function,

  20. Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

    Directory of Open Access Journals (Sweden)

    Saatchi Mahesh Kuwelker

    2017-01-01

    Full Text Available Tricuspid valve (TV injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD with Amplatzer ductal occluder I (ADO I, requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR.

  1. The off-label use of the Amplatzer muscular VSD occluder for large patent ductus arteriosus: a case report and review.

    Science.gov (United States)

    Cubeddu, Roberto J; Babin, Ivan; Inglessis, Ignacio

    2014-07-01

    A percutaneous approach to the closure of patent ductus arteriosus (PDA) is the preferred procedure in the majority of cases. However, there is little experience with percutaneous closure of unusually large PDA. We report the case of a 28-year-old female with moderate left ventricular dilation and pulmonary hypertension resulting from a large 16 mm PDA. Percutaneous closure was successfully performed using an off-label Amplatzer muscular ventricular septal defect occluder after intravascular ultrasound assessment. Technical challenges, including accurate assessment of defect size and device selection are exemplified along with a comprehensive overview of the available literature.

  2. Adaptive partial volume classification of MRI data

    International Nuclear Information System (INIS)

    Chiverton, John P; Wells, Kevin

    2008-01-01

    Tomographic biomedical images are commonly affected by an imaging artefact known as the partial volume (PV) effect. The PV effect produces voxels composed of a mixture of tissues in anatomical magnetic resonance imaging (MRI) data resulting in a continuity of these tissue classes. Anatomical MRI data typically consist of a number of contiguous regions of tissues or even contiguous regions of PV voxels. Furthermore discontinuities exist between the boundaries of these contiguous image regions. The work presented here probabilistically models the PV effect using spatial regularization in the form of continuous Markov random fields (MRFs) to classify anatomical MRI brain data, simulated and real. A unique approach is used to adaptively control the amount of spatial regularization imposed by the MRF. Spatially derived image gradient magnitude is used to identify the discontinuities between image regions of contiguous tissue voxels and PV voxels, imposing variable amounts of regularization determined by simulation. Markov chain Monte Carlo (MCMC) is used to simulate the posterior distribution of the probabilistic image model. Promising quantitative results are presented for PV classification of simulated and real MRI data of the human brain.

  3. Experts' understanding of partial derivatives using the Partial Derivative Machine

    OpenAIRE

    Roundy, David; Dorko, Allison; Dray, Tevian; Manogue, Corinne A.; Weber, Eric

    2014-01-01

    Partial derivatives are used in a variety of different ways within physics. Most notably, thermodynamics uses partial derivatives in ways that students often find confusing. As part of a collaboration with mathematics faculty, we are at the beginning of a study of the teaching of partial derivatives, a goal of better aligning the teaching of multivariable calculus with the needs of students in STEM disciplines. As a part of this project, we have performed a pilot study of expert understanding...

  4. Balloon test occlusion of the internal carotid artery with stable xenon/CT cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Erba, S.M.; Horton, J.A.; Latchaw, R.E.; Yonas, H.; Sekhar, L.; Schramm, V.; Pentheny, S.

    1988-01-01

    We describe a technique to predict preoperatively the safety of permanently occluding an internal carotid artery. The method was performed by imaging stable xenon cerebral blood flow (CBF) with the internal carotid artery both open and temporarily occluded with a nondetachable balloon on a double lumen Swan-Ganz catheter. Patients were those in whom we planned to sacrifice the internal carotid artery (those with giant or inaccessible aneurysms) or those in whom such a sacrifice was at least likely (those with skull base tumors). Patients were divided into three groups on the basis of a comparison of occluded and nonoccluded CBF values. Group-I patients had no significant change in CBF with internal carotid artery occlusion; group-II patients showed a symmetric decrease in CBF; and group-III patients had an asymmetric decrease in CBF, always greater on the occluded side. A fourth group clinically failed to tolerate even brief carotid occlusion. The internal carotid artery in one patients from group III was sacrificed at surgery: the size and shape of his postoperative infarct corresponded almost exactly to the area of asymmetrically decreased CBF on his occluded study. The data suggest that if surgery is likely to result in permanent occlusion of the internal carotid artery, then patients who are at risk for delayed neurologic injury due to a compromised cerebral blood flow should have arterial bypass grafts before such surgery is performed

  5. Chronic pulmonary embolism - radiological imaging and differential diagnosis; Chronische Lungenembolie - Radiologische Bildmorphologie und Differenzialdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Coppenrath, E.; Herzog, P.; Attenberger, U.; Reiser, M. [Klinikum Innenstadt der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2007-08-15

    In chronic pulmonary embolism branches of the pulmonary arterial tree remain partially or totally occluded. This may lead to pulmonary hypertension with the development of right ventricular hypertrophy as well as structural changes of pulmonary arteries. Imaging of chronic pulmonary embolism should prove vessel occlusions (pulmonary angiography, MSCT, MRI) and reduction of regional lung perfusion (lung scanning, MSCT, MRI). According to current guidelines ventilation-perfusion lung scanning and pulmonary angiography are still recommended as the methods of choice. MSCT and MRI provide technical alternatives which are helpful in differential diagnosis versus other types of pulmonary hypertension. In spite of medical and surgical measures (in rare cases pulmonary thromboendarterectomy) the prognosis of chronic pulmonary embolism remains unfavourable. (orig.) [German] Bei der chronischen Lungenembolie sind Abschnitte der arteriellen Lungenstrombahn dauerhaft verschlossen. Dies kann zu einer Erhoehung des pulmonal-arteriellen Drucks mit den Folgen einer Rechtsherzbelastung und strukturellen Veraenderungen der Pulmonalarterien fuehren. Bildmorphologisch nachzuweisen sind Gefaessverschluesse (Pulmonalisangiographie, MSCT, MRT) und die Minderperfusion des Lungenparenchyms (Szintigraphie, MSCT, MRT). Nach den bisherigen Empfehlungen gelten fuer die Diagnostik der chronischen Lungenembolie die Lungenszintigraphie (Ventilation/Perfusion) und die Pulmonalisangiographie als Methoden der ersten Wahl. Die MSCT und MRT (Angiographie/Perfusion) stellen technische Alternativen dar. Differenzialdiagnostisch sind andere Formen der pulmonalen Hypertonie abzugrenzen. Trotz medikamentoeser und chirurgischer Therapiemassnahmen (z. B. pulmonale Thrombendarterektomie) bleibt die Prognose der chronischen Lungenembolie unguenstig. (orig.)

  6. Partial Actions and Power Sets

    Directory of Open Access Journals (Sweden)

    Jesús Ávila

    2013-01-01

    Full Text Available We consider a partial action (X,α with enveloping action (T,β. In this work we extend α to a partial action on the ring (P(X,Δ,∩ and find its enveloping action (E,β. Finally, we introduce the concept of partial action of finite type to investigate the relationship between (E,β and (P(T,β.

  7. Algorithms over partially ordered sets

    DEFF Research Database (Denmark)

    Baer, Robert M.; Østerby, Ole

    1969-01-01

    in partially ordered sets, answer the combinatorial question of how many maximal chains might exist in a partially ordered set withn elements, and we give an algorithm for enumerating all maximal chains. We give (in § 3) algorithms which decide whether a partially ordered set is a (lower or upper) semi......-lattice, and whether a lattice has distributive, modular, and Boolean properties. Finally (in § 4) we give Algol realizations of the various algorithms....

  8. Partial order infinitary term rewriting

    DEFF Research Database (Denmark)

    Bahr, Patrick

    2014-01-01

    We study an alternative model of infinitary term rewriting. Instead of a metric on terms, a partial order on partial terms is employed to formalise convergence of reductions. We consider both a weak and a strong notion of convergence and show that the metric model of convergence coincides with th...... to the metric setting -- orthogonal systems are both infinitarily confluent and infinitarily normalising in the partial order setting. The unique infinitary normal forms that the partial order model admits are Böhm trees....

  9. On Degenerate Partial Differential Equations

    OpenAIRE

    Chen, Gui-Qiang G.

    2010-01-01

    Some of recent developments, including recent results, ideas, techniques, and approaches, in the study of degenerate partial differential equations are surveyed and analyzed. Several examples of nonlinear degenerate, even mixed, partial differential equations, are presented, which arise naturally in some longstanding, fundamental problems in fluid mechanics and differential geometry. The solution to these fundamental problems greatly requires a deep understanding of nonlinear degenerate parti...

  10. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  11. Partial Epilepsy with Auditory Features

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2004-07-01

    Full Text Available The clinical characteristics of 53 sporadic (S cases of idiopathic partial epilepsy with auditory features (IPEAF were analyzed and compared to previously reported familial (F cases of autosomal dominant partial epilepsy with auditory features (ADPEAF in a study at the University of Bologna, Italy.

  12. Partial twisting for scalar mesons

    International Nuclear Information System (INIS)

    Agadjanov, Dimitri; Meißner, Ulf-G.; Rusetsky, Akaki

    2014-01-01

    The possibility of imposing partially twisted boundary conditions is investigated for the scalar sector of lattice QCD. According to the commonly shared belief, the presence of quark-antiquark annihilation diagrams in the intermediate state generally hinders the use of the partial twisting. Using effective field theory techniques in a finite volume, and studying the scalar sector of QCD with total isospin I=1, we however demonstrate that partial twisting can still be performed, despite the fact that annihilation diagrams are present. The reason for this are delicate cancellations, which emerge due to the graded symmetry in partially quenched QCD with valence, sea and ghost quarks. The modified Lüscher equation in case of partial twisting is given

  13. ERC Workshop on Geometric Partial Differential Equations

    CERN Document Server

    Novaga, Matteo; Valdinoci, Enrico

    2013-01-01

    This book is the outcome of a conference held at the Centro De Giorgi of the Scuola Normale of Pisa in September 2012. The aim of the conference was to discuss recent results on nonlinear partial differential equations, and more specifically geometric evolutions and reaction-diffusion equations. Particular attention was paid to self-similar solutions, such as solitons and travelling waves, asymptotic behaviour, formation of singularities and qualitative properties of solutions. These problems arise in many models from Physics, Biology, Image Processing and Applied Mathematics in general, and have attracted a lot of attention in recent years.

  14. Rapid release of 42K and 86Rb from an occluded state of the Na,K-pump in the presence of ATP or ADP

    International Nuclear Information System (INIS)

    Forbush, B. III

    1987-01-01

    We have measured the time course of release of 42 K and 86 Rb from an occluded state of the Na,K-pump using a rapid filtration apparatus. We have found that at 20 degrees C and in the presence of ATP, 42 K is released with a rate constant of approximately 45 s-1 and 86 Rb with a rate constant of approximately 20 s-1; both ATP and ADP are effective at a low affinity site (Kd approximately 0.3 and 1 mM, respectively) with the rate of deocclusion being only half as great in ADP as in ATP. Mg2+ stimulates 2-fold at low concentrations probably by forming MgATP, and free Mg2+ is strongly inhibitory at high concentrations (Kd approximately 10 mM). Mg2+ also decreases the affinity for ATP, and the data are consistent with mixed type inhibition; from the analysis the dissociation constant is approximately 1 mM for the inhibitory Mg2+ and the Rb+-occluded form without ATP. The rate of 42 K or 86 Rb release increases monotonically with pH while ATPase activity decreases above pH 8, so that deocclusion is not rate-limiting in the overall cycle at high pH. This is reflected by a convergence of the rate of Na,K-ATPase and Na,Rb-ATPase activities at high pH and by a decrease in the observed steady-state level of the occluded 86 Rb intermediate at high pH. K+, Rb+, Na+, and Cs+, but not Li+, increase the rate of 42 K and 86 Rb release at constant ionic strength, presumably at sites other than the transport sites. The spontaneous rate of deocclusion is only approximately 0.1 s-1 at low ionic strength in the absence of nucleotides, and it is increased markedly by all cations tested except Li+. Overall the data are consistent with deocclusion as a rate-limiting step in the Na,K-pump cycle

  15. Long Term Effects of Percutaneous Coronary Intervention of the Totally Occluded Infarct-Related Artery in the Subacute Phase after Myocardial Infarction

    Science.gov (United States)

    Hochman, Judith S; Reynolds, Harmony R; Džavík, Vladimír; Buller, Christopher E; Ruzyllo, Witold; Sadowski, Zygmunt P; Maggioni, Aldo P; Carvalho, Antonio C; Rankin, James M.; White, Harvey D.; Goldberg, Suzanne; Forman, Sandra A; Mark, Daniel B; Lamas, Gervasio A

    2011-01-01

    Background Despite observations suggesting a benefit for late opening of occluded infarct-related arteries (IRA) post-myocardial infarction (MI), the Occluded Artery Trial (OAT) demonstrated no reduction in the composite of death, reinfarction and class IV heart failure (HF) over 2.9-yearmean follow-up. Follow-up was extended to determine whether late trends would favor either treatment group. Methods and Results OAT randomized 2201 stable patients with IRA occlusion >24hours (calendar days3-28) after MI. Severe inducible ischemia, rest angina, class III-IV HF and 3-vessel/left main disease were excluded. We conducted extended followed up of enrolled patients for an additional 3 years for the primary endpoint and angina (6-year median survivor follow up, longest 9 years, 12,234 patient-years).Rates of the primary endpoint (HR 1.06, 95% CI 0.88-1.28), fatal and nonfatal MI (HR 1.25, 95% CI 0.89-1.75), death and class IV HF were similar for PCI vs. MED groups. No interaction between baseline characteristics and treatment group on outcomes were observed. The vast majority of patients at each follow-up visit did not report angina. There was less angina in the PCI group through early in follow-up; by 3 years the between group difference was consistently <4 patients per 100 treated and not significantly different though there was a trend toward less angina in the PCI group at 3 and 5 years. The 7-year rate of PCI of the IRA during follow up was 11.1% for the PCI group compared to 14.7% for the MED group (HR 0.79, 95% CI 0.61-1.01. p=0.06). Conclusions Extended follow up of the OAT cohort provides robust evidence for no reduction of long-term rates of clinical events after routine PCI in stable patients with an occluded IRA and without severe inducible ischemia in the subacute phase post-MI. PMID:22025606

  16. Long-Term Primary Patency Rate After Nitinol Self-Expandable Stents Implantation in Long, Totally Occluded Femoropopliteal (TASC II C & D) Lesions.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; Buonamici, Piergiovanni; Trapani, Maurizio; Valenti, Renato; Migliorini, Angela; Parodi, Guido; Antoniucci, David

    2017-06-01

    Endovascular therapy for long femoropopliteal lesions using percutaneous transluminal balloon angioplasty or first-generation of peripheral stents has been associated with unacceptable one-year restenosis rates. However, with recent advances in equipment and techniques, a better primary patency rate is expected. This study was conducted to detect the long-term primary patency rate of nitinol self-expandable stents implanted in long, totally occluded femoropopliteal lesions TransAtlantic Inter-Society Census (TASC II type C & D), and determine the predictors of reocclusion or restenosis in the stented segments. The demographics, clinical, anatomical, and procedural data of 213 patients with 240 de novo totally occluded femoropopliteal (TASC II type C & D) lesions treated with nitinol self-expandable stents were retrospectively analysed. Of these limbs, 159 (66.2%) presented with intermittent claudication, while 81 (33.8%) presented with critical limb ischaemia. The mean-time of follow-up was 36±22.6 months, (range: 6.3-106.2 months). Outcomes evaluated were, primary patency rate and predictors of reocclusion or restenosis in the stented segments. The mean age of the patients was 70.9±9.3 years, with male gender 66.2%. Mean pre-procedural ABI was 0.45±0.53. One-hundred-and-seventy-five (73%) lesions were TASC II type C, while 65 (27%) were type D lesions. The mean length of the lesions was 17.9±11.3mm. Procedure related complications occurred in 10 (4.1%) limbs. There was no periprocedural mortality. Reocclusion and restenosis were detected during follow-up in 45 and 30 limbs respectively, and all were re-treated by endovascular approach. None of the patients required major amputation. Primary patency rates were 81.4±1.1%, 77.7±1.9% and 74.4±2.8% at 12, 24, and 36 months respectively. Male gender, severe calcification, and TASC II D lesion were independent predictors for reocclusion, while predictors of restenosis were DM, smoking and TASC II D lesions

  17. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  18. SVM-based Partial Discharge Pattern Classification for GIS

    Science.gov (United States)

    Ling, Yin; Bai, Demeng; Wang, Menglin; Gong, Xiaojin; Gu, Chao

    2018-01-01

    Partial discharges (PD) occur when there are localized dielectric breakdowns in small regions of gas insulated substations (GIS). It is of high importance to recognize the PD patterns, through which we can diagnose the defects caused by different sources so that predictive maintenance can be conducted to prevent from unplanned power outage. In this paper, we propose an approach to perform partial discharge pattern classification. It first recovers the PRPD matrices from the PRPD2D images; then statistical features are extracted from the recovered PRPD matrix and fed into SVM for classification. Experiments conducted on a dataset containing thousands of images demonstrates the high effectiveness of the method.

  19. Coding with partially hidden Markov models

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Rissanen, J.

    1995-01-01

    Partially hidden Markov models (PHMM) are introduced. They are a variation of the hidden Markov models (HMM) combining the power of explicit conditioning on past observations and the power of using hidden states. (P)HMM may be combined with arithmetic coding for lossless data compression. A general...... 2-part coding scheme for given model order but unknown parameters based on PHMM is presented. A forward-backward reestimation of parameters with a redefined backward variable is given for these models and used for estimating the unknown parameters. Proof of convergence of this reestimation is given....... The PHMM structure and the conditions of the convergence proof allows for application of the PHMM to image coding. Relations between the PHMM and hidden Markov models (HMM) are treated. Results of coding bi-level images with the PHMM coding scheme is given. The results indicate that the PHMM can adapt...

  20. Avaliação geoquímica de biomarcadores ocluídos em estruturas asfaltênicas Geochemical evaluation of occluded biomarkers in asphaltenic structures

    Directory of Open Access Journals (Sweden)

    Débora de Almeida Azevedo

    2009-01-01

    Full Text Available Asphaltenes from two Brazilian crude oils were submitted to mild oxidation to disrupt their structure, releasing the occluded oil. The released hydrocarbons were compared with those from the original crude oil, and used to evaluate the alteration of the oils, especially as a result of biodegradation, but also thermal maturity. The crude oils used are depleted in n-alkanes, which are usually related to biodegradation. However, the released products from the corresponding asphaltenes have n-alkane distributions from nC10 to nC40, suggesting a protection effect from biodegradation. The m/z 191 mass chromatograms showed higher relative intensities for tricyclic terpanes than the hopanes in the crude in comparison with the released ones.

  1. Balloon-Occluded Antegrade Transvenous Sclerotherapy to Treat Rectal Varices: A Direct Puncture Approach to the Superior Rectal Vein Through the Greater Sciatic Foramen Under CT Fluoroscopy Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Yasuyuki, E-mail: onoyasy@hirakata.kmu.ac.jp; Kariya, Shuji, E-mail: kariyas@hirakata.kmu.ac.jp; Nakatani, Miyuki, E-mail: nakatanm@hirakata.kmu.ac.jp; Yoshida, Rie, E-mail: yagir@hirakata.kmu.ac.jp; Kono, Yumiko, E-mail: kohnoy@hirakata.kmu.ac.jp; Kan, Naoki, E-mail: kanna@takii.kmu.ac.jp; Ueno, Yutaka, E-mail: uenoyut@hirakata.kmu.ac.jp; Komemushi, Atsushi, E-mail: komemush@takii.kmu.ac.jp; Tanigawa, Noboru, E-mail: tanigano@hirakata.kmu.ac.jp [Kansai Medical University, Department of Radiology (Japan)

    2015-10-15

    Rectal varices occur in 44.5 % of patients with ectopic varices caused by portal hypertension, and 48.6 % of these patients are untreated and followed by observation. However, bleeding occurs in 38 % and shock leading to death in 5 % of such patients. Two patients, an 80-year-old woman undergoing treatment for primary biliary cirrhosis (Child-Pugh class A) and a 63-year-old man with class C hepatic cirrhosis (Child-Pugh class A), in whom balloon-occluded antegrade transvenous sclerotherapy was performed to treat rectal varices are reported. A catheter was inserted by directly puncturing the rectal vein percutaneously through the greater sciatic foramen under computed tomographic fluoroscopy guidance. In both cases, the rectal varices were successfully treated without any significant complications, with no bleeding from rectal varices after embolization.

  2. [Closure of wide patent ductus arteriosus using a fenestrated muscular VSD occluder device in a pediatric patient with Down syndrome and pulmonary hypertension].

    Science.gov (United States)

    Güvenç, Osman; Saygı, Murat; Demir, İbrahim Halil; Ödemiş, Ender

    2017-06-01

    Patients with wide patent ductus arteriosus and significant pulmonary hypertension not treated in time constitute a significant problem for cardiologists. For these patients, tests that could aid in decision-making for further planning include reversibility and balloon occlusion tests performed in the catheterization laboratory. Devices developed for the closure of ductus as well as different devices with off-label use may be employed in patients scheduled for transcatheter occlusion. When result of reversibility test is borderline positive, the use of fenestrated device may be applicable for selected patients. Presently described is case of a 10-year-old patient with Down syndrome who had a wide ductus and systemic pulmonary hypertension. Transcatheter closure procedure was performed with off-label use of a fenestrated muscular ventricular septal defect occluder device.

  3. Physics of partially ionized plasmas

    CERN Document Server

    Krishan, Vinod

    2016-01-01

    Plasma is one of the four fundamental states of matter; the other three being solid, liquid and gas. Several components, such as molecular clouds, diffuse interstellar gas, the solar atmosphere, the Earth's ionosphere and laboratory plasmas, including fusion plasmas, constitute the partially ionized plasmas. This book discusses different aspects of partially ionized plasmas including multi-fluid description, equilibrium and types of waves. The discussion goes on to cover the reionization phase of the universe, along with a brief description of high discharge plasmas, tokomak plasmas and laser plasmas. Various elastic and inelastic collisions amongst the three particle species are also presented. In addition, the author demonstrates the novelty of partially ionized plasmas using many examples; for instance, in partially ionized plasma the magnetic induction is subjected to the ambipolar diffusion and the Hall effect, as well as the usual resistive dissipation. Also included is an observation of kinematic dynam...

  4. Partially massless fields during inflation

    Science.gov (United States)

    Baumann, Daniel; Goon, Garrett; Lee, Hayden; Pimentel, Guilherme L.

    2018-04-01

    The representation theory of de Sitter space allows for a category of partially massless particles which have no flat space analog, but could have existed during inflation. We study the couplings of these exotic particles to inflationary perturbations and determine the resulting signatures in cosmological correlators. When inflationary perturbations interact through the exchange of these fields, their correlation functions inherit scalings that cannot be mimicked by extra massive fields. We discuss in detail the squeezed limit of the tensor-scalar-scalar bispectrum, and show that certain partially massless fields can violate the tensor consistency relation of single-field inflation. We also consider the collapsed limit of the scalar trispectrum, and find that the exchange of partially massless fields enhances its magnitude, while giving no contribution to the scalar bispectrum. These characteristic signatures provide clean detection channels for partially massless fields during inflation.

  5. Introduction to partial differential equations

    CERN Document Server

    Greenspan, Donald

    2000-01-01

    Designed for use in a one-semester course by seniors and beginning graduate students, this rigorous presentation explores practical methods of solving differential equations, plus the unifying theory underlying the mathematical superstructure. Topics include basic concepts, Fourier series, second-order partial differential equations, wave equation, potential equation, heat equation, approximate solution of partial differential equations, and more. Exercises appear at the ends of most chapters. 1961 edition.

  6. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  7. Image formation and image analysis in electron microscopy

    International Nuclear Information System (INIS)

    Heel, M. van.

    1981-01-01

    This thesis covers various aspects of image formation and image analysis in electron microscopy. The imaging of relatively strong objects in partially coherent illumination, the coherence properties of thermionic emission sources and the detection of objects in quantum noise limited images are considered. IMAGIC, a fast, flexible and friendly image analysis software package is described. Intelligent averaging of molecular images is discussed. (C.F.)

  8. No prognostic significance of chronic infection with Chlamydia pneumoniae in acute coronary syndromes: insights from the Global Utilization of Strategies to Open Occluded Arteries IV Acute Coronary Syndromes trial

    DEFF Research Database (Denmark)

    Westerhout, Cynthia M; Gnarpe, Judy; Chang, Wei-Ching

    2007-01-01

    case-control substudy of the Global Utilization of Strategies to Open Occluded Arteries IV Acute Coronary Syndromes trial, 295 cases (30-day death/myocardial infarction [MI]) were matched by age, sex, baseline creatine kinase-myocardial kinase, and smoking status with 295 control subjects. To test...

  9. Results of the combined U.S. Multicenter Pivotal Study and the Continuing Access Study of the Nit-Occlud PDA device for percutaneous closure of patent ductus arteriosus.

    Science.gov (United States)

    Moore, John W; Greene, Jessica; Palomares, Salvadore; Javois, Alexander; Owada, Carl Y; Cheatham, John P; Hoyer, Mark H; Jones, Thomas K; Levi, Daniel S

    2014-12-01

    This study aimed to compare the efficacy and safety of the Nit-Occlud PDA device (PFM Medical, Cologne, Germany) to benchmarks designed as objective performance criteria (OPC). The Nit-Occlud PDA is a nitinol coil-type patent ductus arteriosus (PDA) occluder with a reverse cone configuration, which is implanted using a controlled delivery system. Patients with closure (clinical and echocardiographic), and safety criteria incidence of adverse events (serious and of total). The Pivotal Study enrolled patients between November 1, 2002 and October 31, 2005, and the Continuing Access Study enrolled additional patients between September 1, 2006 and October 31, 2007. A total of 357 patients were enrolled, and 347 had successful device implantations. After 12 months, 96.8% had complete echocardiographic closure (OPC = 85%) and 98.1% had clinical closure (OPC = 95%). There were no deaths or serious adverse events (OPC = 1%). The total adverse event rate was 4.7% (OPC = 6%). Composite success was 95.1% in the study patients (OPC = 80%). Closure of small- and medium-sized PDA with the Nit-Occlud PDA is effective and safe when compared with OPC. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Imágenes ecográficas de la mola hidatiforme parcial en el segundo trimestre del embarazo Ultrasound imaging of partial hydatidiform mole in the second trimester of pregnancy

    Directory of Open Access Journals (Sweden)

    Marina Jover Labiste

    2012-01-01

    Full Text Available Se describe el caso clínico de una paciente de 27 años de edad y 18 semanas de gestación, ingresada en el Servicio de Obstetricia del Hospital Ginecoobstétrico Provincial "Mariana Grajales Coello" de Santiago de Cuba, por presentar cifras tensionales elevadas, cefalea y dolor en bajo vientre. Los exámenes complementarios efectuados confirmaron que se trataba de una mola hidatiforme parcial, por lo cual se legró la cavidad uterina y se extrajeron pequeños fragmentos de estroma endometrial para estudio anatomopatológico. Se indicó seguimiento médico por consulta externa y se citó a los 21 días para el control y la evaluación de su estado general.The case report of a 27 year-old patient with 18 weeks gestation, admitted to the Obstetrics Department of "Mariana Grajales Coello" Provincial Gynecology and Obstetrics Hospital of Santiago de Cuba due to high blood pressure, cephalea and pain in lower abdomen is described. Additional tests confirmed a partial hydatidiform mole, so that uterine curettage was performed and small fragments of endometrial stroma were removed for pathological study. Outpatient medical monitoring was recommended and the patient had an appointment at 21 days for controlling and evaluating her general state.

  11. Partial Volume Effects correction in emission tomography

    International Nuclear Information System (INIS)

    Le Pogam, Adrien

    2010-01-01

    Partial Volume Effects (PVE) designates the blur commonly found in nuclear medicine images and this PhD work is dedicated to their correction with the objectives of qualitative and quantitative improvement of such images. PVE arise from the limited spatial resolution of functional imaging with either Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT). They can be defined as a signal loss in tissues of size similar to the Full Width at Half Maximum (FWHM) of the PSF of the imaging device. In addition, PVE induce activity cross contamination between adjacent structures with different tracer uptakes. This can lead to under or over estimation of the real activity of such analyzed regions. Various methodologies currently exist to compensate or even correct for PVE and they may be classified depending on their place in the processing chain: either before, during or after the image reconstruction process, as well as their dependency on co-registered anatomical images with higher spatial resolution, for instance Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). The voxel-based and post-reconstruction approach was chosen for this work to avoid regions of interest definition and dependency on proprietary reconstruction developed by each manufacturer, in order to improve the PVE correction. Two different contributions were carried out in this work: the first one is based on a multi-resolution methodology in the wavelet domain using the higher resolution details of a co-registered anatomical image associated to the functional dataset to correct. The second one is the improvement of iterative deconvolution based methodologies by using tools such as directional wavelets and curvelets extensions. These various developed approaches were applied and validated using synthetic, simulated and clinical images, for instance with neurology and oncology applications in mind. Finally, as currently available PET/CT scanners incorporate more

  12. Parachute technique for partial penectomy

    Directory of Open Access Journals (Sweden)

    Fernando Korkes

    2010-04-01

    Full Text Available PURPOSE: Penile carcinoma is a rare but mutilating malignancy. In this context, partial penectomy is the most commonly applied approach for best oncological results. We herein propose a simple modification of the classic technique of partial penectomy, for better cosmetic and functional results. TECHNIQUE: If partial penectomy is indicated, the present technique can bring additional benefits. Different from classical technique, the urethra is spatulated only ventrally. An inverted "V" skin flap with 0.5 cm of extension is sectioned ventrally. The suture is performed with vicryl 4-0 in a "parachute" fashion, beginning from the ventral portion of the urethra and the "V" flap, followed by the "V" flap angles and than by the dorsal portion of the penis. After completion of the suture, a Foley catheter and light dressing are placed for 24 hours. CONCLUSIONS: Several complex reconstructive techniques have been previously proposed, but normally require specific surgical abilities, adequate patient selection and staged procedures. We believe that these reconstructive techniques are very useful in some specific subsets of patients. However, the technique herein proposed is a simple alternative that can be applied to all men after a partial penectomy, and takes the same amount of time as that in the classic technique. In conclusion, the "parachute" technique for penile reconstruction after partial amputation not only improves the appearance of the penis, but also maintains an adequate function.

  13. Partial Transposition on Bipartite System

    International Nuclear Information System (INIS)

    Xi-Jun, Ren; Yong-Jian, Han; Yu-Chun, Wu; Guang-Can, Guo

    2008-01-01

    Many properties of partial transposition are unclear as yet. Here we carefully consider the number of the negative eigenvalues of ρ T (ρ's partial transposition) when ρ is a two-partite state. There is strong evidence to show that the number of negative eigenvalues of ρ T is N(N − 1)/2 at most when ρ is a state in Hilbert space C N C N . For the special case, the 2 × 2 system, we use this result to give a partial proof of the conjecture |ρ T | T ≥ 0. We find that this conjecture is strongly connected with the entanglement of the state corresponding to the negative eigenvalue of ρ T or the negative entropy of ρ

  14. Partially composite Goldstone Higgs boson

    DEFF Research Database (Denmark)

    Alanne, Tommi; Franzosi, Diogo Buarque; Frandsen, Mads T.

    2017-01-01

    We consider a model of dynamical electroweak symmetry breaking with a partially composite Goldstone Higgs boson. The model is based on a strongly interacting fermionic sector coupled to a fundamental scalar sector via Yukawa interactions. The SU(4)×SU(4) global symmetry of these two sectors...... is broken to a single SU(4) via Yukawa interactions. Electroweak symmetry breaking is dynamically induced by condensation due to the strong interactions in the new fermionic sector which further breaks the global symmetry SU(4)→Sp(4). The Higgs boson arises as a partially composite state which is an exact...... Goldstone boson in the limit where SM interactions are turned off. Terms breaking the SU(4) global symmetry explicitly generate a mass for the Goldstone Higgs boson. The model realizes in different limits both (partially) composite Higgs and (bosonic) technicolor models, thereby providing a convenient...

  15. Landsliding in partially saturated materials

    Science.gov (United States)

    Godt, J.W.; Baum, R.L.; Lu, N.

    2009-01-01

    [1] Rainfall-induced landslides are pervasive in hillslope environments around the world and among the most costly and deadly natural hazards. However, capturing their occurrence with scientific instrumentation in a natural setting is extremely rare. The prevailing thinking on landslide initiation, particularly for those landslides that occur under intense precipitation, is that the failure surface is saturated and has positive pore-water pressures acting on it. Most analytic methods used for landslide hazard assessment are based on the above perception and assume that the failure surface is located beneath a water table. By monitoring the pore water and soil suction response to rainfall, we observed shallow landslide occurrence under partially saturated conditions for the first time in a natural setting. We show that the partially saturated shallow landslide at this site is predictable using measured soil suction and water content and a novel unified effective stress concept for partially saturated earth materials. Copyright 2009 by the American Geophysical Union.

  16. Basic linear partial differential equations

    CERN Document Server

    Treves, Francois

    1975-01-01

    Focusing on the archetypes of linear partial differential equations, this text for upper-level undergraduates and graduate students features most of the basic classical results. The methods, however, are decidedly nontraditional: in practically every instance, they tend toward a high level of abstraction. This approach recalls classical material to contemporary analysts in a language they can understand, as well as exploiting the field's wealth of examples as an introduction to modern theories.The four-part treatment covers the basic examples of linear partial differential equations and their

  17. Elements of partial differential equations

    CERN Document Server

    Sneddon, Ian Naismith

    1957-01-01

    Geared toward students of applied rather than pure mathematics, this volume introduces elements of partial differential equations. Its focus is primarily upon finding solutions to particular equations rather than general theory.Topics include ordinary differential equations in more than two variables, partial differential equations of the first and second orders, Laplace's equation, the wave equation, and the diffusion equation. A helpful Appendix offers information on systems of surfaces, and solutions to the odd-numbered problems appear at the end of the book. Readers pursuing independent st

  18. Laparoscopic Partial Hepatectomy of Focal Nodular Hyperplasia

    Directory of Open Access Journals (Sweden)

    Mayu Sakata

    2012-11-01

    Full Text Available Focal nodular hyperplasia is a benign liver lesion incidentally discovered with increasing frequency because of the proliferation of imaging studies. Radiographic characterization can diagnose this pathologic lesion and nonoperative therapy is the standard of care. However, surgical resection may be required for diagnostic reasons or symptomatic patients. Depending on the anatomic location of the lesion, biopsy and/or resection can be performed laparoscopically. We herein report the case of a 26-year-old Japanese woman with a hepatic tumor who required a medical examination. Her medical history was negative for alcohol abuse, oral contraceptive administration and trauma. Clinical examination showed no significant symptoms. Ultrasonography, computed tomography and magnetic resonance imaging showed a mass located in the left lateral segment of the liver with a diameter of about 40 mm. It was difficult to diagnose the tumor definitively from these imaging studies, so we performed laparoscopic partial hepatectomy with successive firing of endoscopic staplers. The histopathological diagnosis was focal nodular hyperplasia. Surgical procedures and postoperative course were uneventful and the patient was discharged from the hospital on postoperative day 5.

  19. Timed Testing under Partial Observability

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Li, Shuhao

    2009-01-01

    observability of SUT using a set of predicates over the TGA state space, and specify the test purposes in Computation Tree Logic (CTL) formulas. A recently developed partially observable timed game solver is used to generate winning strategies, which are used as test cases. We propose a conformance testing...

  20. Variable Selection via Partial Correlation.

    Science.gov (United States)

    Li, Runze; Liu, Jingyuan; Lou, Lejia

    2017-07-01

    Partial correlation based variable selection method was proposed for normal linear regression models by Bühlmann, Kalisch and Maathuis (2010) as a comparable alternative method to regularization methods for variable selection. This paper addresses two important issues related to partial correlation based variable selection method: (a) whether this method is sensitive to normality assumption, and (b) whether this method is valid when the dimension of predictor increases in an exponential rate of the sample size. To address issue (a), we systematically study this method for elliptical linear regression models. Our finding indicates that the original proposal may lead to inferior performance when the marginal kurtosis of predictor is not close to that of normal distribution. Our simulation results further confirm this finding. To ensure the superior performance of partial correlation based variable selection procedure, we propose a thresholded partial correlation (TPC) approach to select significant variables in linear regression models. We establish the selection consistency of the TPC in the presence of ultrahigh dimensional predictors. Since the TPC procedure includes the original proposal as a special case, our theoretical results address the issue (b) directly. As a by-product, the sure screening property of the first step of TPC was obtained. The numerical examples also illustrate that the TPC is competitively comparable to the commonly-used regularization methods for variable selection.

  1. Partially molten magma ocean model

    International Nuclear Information System (INIS)

    Shirley, D.N.

    1983-01-01

    The properties of the lunar crust and upper mantle can be explained if the outer 300-400 km of the moon was initially only partially molten rather than fully molten. The top of the partially molten region contained about 20% melt and decreased to 0% at 300-400 km depth. Nuclei of anorthositic crust formed over localized bodies of magma segregated from the partial melt, then grew peripherally until they coverd the moon. Throughout most of its growth period the anorthosite crust floated on a layer of magma a few km thick. The thickness of this layer is regulated by the opposing forces of loss of material by fractional crystallization and addition of magma from the partial melt below. Concentrations of Sr, Eu, and Sm in pristine ferroan anorthosites are found to be consistent with this model, as are trends for the ferroan anorthosites and Mg-rich suites on a diagram of An in plagioclase vs. mg in mafics. Clustering of Eu, Sr, and mg values found among pristine ferroan anorthosites are predicted by this model

  2. [Posterior ceramic bonded partial restorations].

    Science.gov (United States)

    Mainjot, Amélie; Vanheusden, Alain

    2006-01-01

    Posterior ceramic bonded partial restorations are conservative and esthetic approaches for compromised teeth. Overlays constitute a less invasive alternative for tooth tissues than crown preparations. With inlays and onlays they are also indicated in case of full arch or quadrant rehabilitations including several teeth. This article screens indications and realization of this type of restorations.

  3. Implementing circularity using partial evaluation

    DEFF Research Database (Denmark)

    Lawall, Julia Laetitia

    2001-01-01

    of an imperative C-like language, by extending the language with a new construct, persistent variables. We show that an extension of partial evaluation can eliminate persistent variables, producing a staged C program. This approach has been implemented in the Tempo specializer for C programs, and has proven useful...

  4. The partial-birth stratagem.

    Science.gov (United States)

    1998-06-01

    In Wisconsin, physicians stopped performing abortions when a Federal District Court Judge refused to issue a temporary restraining order against the state's newly enacted "partial birth" abortion ban that was couched in such vague language it actually covered all abortions. While ostensibly attempting to ban late-term "intact dilation and extraction," the language of the law did not refer to that procedure or to late terms. Instead, it prohibited all abortions in which a physician "partially vaginally delivers a living child, causes the death of the partially delivered child with the intent to kill the child and then completes the delivery of the child." The law also defined "child" as "a human being from the time of fertilization" until birth. It is clear that this abortion ban is unconstitutional under Row v. Wade, and this unconstitutionality is compounded by the fact that the law allowed no exception to protect a woman's health, which is required by Roe for abortion bans after fetal viability. Wisconsin is only one of about 28 states that have enacted similar laws, and only two have restricted the ban to postviability abortions. Many of these laws have been struck down in court, and President Clinton has continued to veto the Federal partial-birth bill. The Wisconsin Judge acknowledged that opponents of the ban will likely prevail when the case is heard, but his action in denying the temporary injunction means that many women in Wisconsin will not receive timely medical care. The partial birth strategy is really only another anti-abortion strategy.

  5. Image, Image, Image

    Science.gov (United States)

    Howell, Robert T.

    2004-01-01

    With all the talk today about accountability, budget cuts, and the closing of programs in public education, teachers cannot overlook the importance of image in the field of industrial technology. It is very easy for administrators to cut ITE (industrial technology education) programs to save school money--money they might shift to teaching the…

  6. Partial anomalous pulmonary venous return in Turner syndrome.

    Science.gov (United States)

    van den Hoven, Allard T; Chelu, Raluca G; Duijnhouwer, Anthonie L; Demulier, Laurent; Devos, Daniel; Nieman, Koen; Witsenburg, Maarten; van den Bosch, Annemien E; Loeys, Bart L; van Hagen, Iris M; Roos-Hesselink, Jolien W

    2017-10-01

    The aim of this study is to describe the prevalence, anatomy, associations and clinical impact of partial anomalous pulmonary venous return in patients with Turner syndrome. All Turner patients who presented at our Turner clinic, between January 2007 and October 2015 were included in this study and underwent ECG, echocardiography and advanced imaging such as cardiac magnetic resonance or computed tomography as part of their regular clinical workup. All imaging was re-evaluated and detailed anatomy was described. Partial anomalous pulmonary venous return was diagnosed in 24 (25%) out of 96 Turner patients included and 14 (58%) of these 24 partial anomalous pulmonary venous return had not been reported previously. Right atrial or ventricular dilatation was present in 11 (46%) of 24 partial anomalous pulmonary venous return patients. When studied with advanced imaging modalities and looked for with specific attention, PAPVR is found in 1 out of 4 Turner patients. Half of these patients had right atrial and/or ventricular dilatation. Evaluation of pulmonary venous return should be included in the standard protocol in all Turner patients. Copyright © 2017. Published by Elsevier B.V.

  7. Fenestration of a Papyrus PK covered stent to recover the occluded left main bifurcation after sealing a left main perforation during a CTO procedure.

    Science.gov (United States)

    Werner, Gerald S; Ahmed, Waqar H

    2017-09-01

    Covered stents are indicated for coronary perforations, but they may seal off major side branches in that process. We report the successful sealing of an ostial left main perforation, induced by a guide catheter in the course of a retrograde approach to treat a chronic total occlusion (CTO) of the right coronary artery (RCA) in a 76year old woman with prior CABG. The implanted Papyrus covered stent, however, overlapped the left main bifurcation and occluded the non-grafted circumflex artery (CX) resulting in acute ischemia. Through a double lumen catheter advanced over the wire located in the left anterior descending coronary artery (LAD) territory, a stiff recanalization wire could be advanced from the side-port to penetrate the stent membrane towards the CX. This was successfully achieved, and after subsequent dilatation, a drug-eluting stent was implanted in Culotte-fashion from the CX to the left main with subsequent kissing-balloon dilatation. The clinical symptoms subsided immediately, and the RCA was finally recanalized in antegrade parallel wire technique. No periprocedural infarct was observed during 48h of follow-up before discharge. At clinical follow-up of 6months the patient is symptom-free. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Long term results of balloon-occluded retrograde transvenous obliteration for portosystemic shunt encephalopathy in patients with liver cirrhosis and portal hypertension.

    Science.gov (United States)

    Inoue, Hiroto; Emori, Keigo; Toyonaga, Atsushi; Oho, Kazuhiko; Kumamoto, Masafumi; Haruta, Tsuyoshi; Mitsuyama, Keiichi; Tsuruta, Osamu; Sata, Michio

    2014-01-01

    This study examined 19 patients with portosystemic shunt encephalopathy caused by a splenorenal shunt (SRS), which was treated with balloon-occluded retrograde transvenous obliteration (B-RTO). Long-term treatment outcomes were evaluated based on hepatic functional reserve and vital prognosis. Encephalopathy improved in all patients after shunt embolization and closure. Albumin, serum ammonia, and the Child-Pugh score, a measure of liver function, were significantly improved 3 years after B-RTO, and exacerbation of damage to liver function was avoided (pliver failure and two patients from hepatocellular carcinoma. Patients had a poor prognosis if their albumin levels were less than 2.8 mg / dL before B-RTO (pEncephalopathy patients had complete response to B-RTO, but long-term prognosis was affected by hepatic functional reserve before B-RTO and by concurrent hepatocellular carcinoma. The results of this study suggest that in patients with SRS, it is important to perform B-RTO at an early stage when the hepatic functional reserve is still satisfactory.

  9. Prevalence and outcome of patients with non-ST segment elevation myocardial infarction with occluded "culprit" artery - a systemic review and meta-analysis.

    Science.gov (United States)

    Hung, Chi-Sheng; Chen, Ying-Hsien; Huang, Ching-Chang; Lin, Mao-Shin; Yeh, Chih-Fan; Li, Hung-Yuan; Kao, Hsien-Li

    2018-02-09

    The aim was to determine the prevalence and impact of an occluded "culprit" artery (OCA) in patients with non-ST segment elevation myocardial infarction (NSTEMI). We searched PubMed, EMBASE, and Web of Science, with no language restrictions, up to 1 Jul. 2016. Observational cohorts or clinical trials of adult NSTEMI were eligible for inclusion to determine the prevalence if the proportion of OCA on coronary angiography was reported. Studies were further eligible for inclusion to determine the outcome if the association between OCA and clinical endpoints was reported. Among the 60,898 patients with NSTEMI enrolled in 25 studies, 17,212 were found to have OCA. The average proportion of OCA in NSTEMI was 34% (95% CI 30-37%). Patients with OCA were more likely to have left circumflex artery as their culprit artery (odds ratio (OR) 1.65, 95% CI 1.15-2.37, p = 0.007), and this was associated with lower left ventricular ejection fraction (standard mean difference -0.29, 95% CI -0.34 to -0.34, p OCA, compared with patients with a non-occlusive culprit artery. Patients with OCA comprised a substantial portion of the NSTEMI population. These patients present with more severe symptoms and worse clinical outcome. Whether these patients should be treated with more aggressive strategy warrants further study.

  10. The strategic value of partial vertical integration

    OpenAIRE

    Fiocco, Raffaele

    2014-01-01

    We investigate the strategic incentives for partial vertical integration, namely, partial ownership agreements between manufacturers and retailers, when retailers privately know their costs and engage in differentiated good price competition. The partial misalignment between the profit objectives within a partially integrated manufacturer-retailer hierarchy entails a higher retail price than under full integration. This `information vertical effect' translates into an opposite ...