WorldWideScience

Sample records for partial volume effects

  1. Partial volume effect in MRI

    International Nuclear Information System (INIS)

    Maeda, Munehiro; Yoshiya, Kazuhiko; Suzuki, Eiji

    1989-01-01

    According to the direction and the thickness of the imaging slice in tomography, the border between the tissues becomes unclear (partial volume effect). In the present MRI experiment, we examined border area between fat and water components using phantom in order to investigate the partial volume effect in MRI. In spin echo sequences, the intensity of the border area showed a linear relationship with composition of fat and water. Whereas, in inversion recovery and field echo sequences, we found the parameters to produce an extremely low intensity area at the border region between fat and water. This low intensity area was explained by cancellation of NMR signals from fat and water due to the difference in the direction of magnetic vectors. Clinically, partial volume effect can cause of mis-evaluation of walls, small nodules, tumor capsules and the tumor invasion in the use of inversion recovery and field echo sequences. (author)

  2. Optimal transformation for correcting partial volume averaging effects in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Soltanian-Zadeh, H.; Windham, J.P.; Yagle, A.E.

    1993-01-01

    Segmentation of a feature of interest while correcting for partial volume averaging effects is a major tool for identification of hidden abnormalities, fast and accurate volume calculation, and three-dimensional visualization in the field of magnetic resonance imaging (MRI). The authors present the optimal transformation for simultaneous segmentation of a desired feature and correction of partial volume averaging effects, while maximizing the signal-to-noise ratio (SNR) of the desired feature. It is proved that correction of partial volume averaging effects requires the removal of the interfering features from the scene. It is also proved that correction of partial volume averaging effects can be achieved merely by a linear transformation. It is finally shown that the optimal transformation matrix is easily obtained using the Gram-Schmidt orthogonalization procedure, which is numerically stable. Applications of the technique to MRI simulation, phantom, and brain images are shown. They show that in all cases the desired feature is segmented from the interfering features and partial volume information is visualized in the resulting transformed images

  3. Quantification of brain tissue through incorporation of partial volume effects

    Science.gov (United States)

    Gage, Howard D.; Santago, Peter, II; Snyder, Wesley E.

    1992-06-01

    This research addresses the problem of automatically quantifying the various types of brain tissue, CSF, white matter, and gray matter, using T1-weighted magnetic resonance images. The method employs a statistical model of the noise and partial volume effect and fits the derived probability density function to that of the data. Following this fit, the optimal decision points can be found for the materials and thus they can be quantified. Emphasis is placed on repeatable results for which a confidence in the solution might be measured. Results are presented assuming a single Gaussian noise source and a uniform distribution of partial volume pixels for both simulated and actual data. Thus far results have been mixed, with no clear advantage being shown in taking into account partial volume effects. Due to the fitting problem being ill-conditioned, it is not yet clear whether these results are due to problems with the model or the method of solution.

  4. Probabilistic Characterization of Partial Volume Effects in Imaging of Rectangular Objects

    Energy Technology Data Exchange (ETDEWEB)

    Bulaevskaya, V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-05-06

    In imaging, a partial volume effect refers to the problem that arises when the system resolution is low relative to the size of the object being imaged [1, 2]. In this setting, it is likely that most voxels occupied by the object are only partially covered, and that the fraction covered in each voxel is low. This makes the problem of object detection and image segmentation very difficult because the algorithms designed for these purposes rely on pixel summary statistics. If the area covered by the object is very low in relatively many of the total number of the voxels the object occupies, these summary statistics may not reach the thresholds required to detect this object. It is thus important to understand the extent of partial volume effect for a given object size and resolution. This technical report focuses on rectangular objects and derives the probability distributions for three quantities for such objects: 1) the number of fully covered voxels, 2) the number of partially covered voxels, and 3) the fractions of the total volume covered in the partially covered voxels. The derivations are first shown for 2-D settings and are then extended to 3-D settings.

  5. Anatomically guided voxel-based partial volume effect correction in brain PET : Impact of MRI segmentation

    NARCIS (Netherlands)

    Gutierrez, Daniel; Montandon, Marie-Louise; Assal, Frederic; Allaoua, Mohamed; Ratib, Osman; Loevblad, Karl-Olof; Zaidi, Habib

    2012-01-01

    Partial volume effect is still considered one of the main limitations in brain PET imaging given the limited spatial resolution of current generation PET scanners. The accuracy of anatomically guided partial volume effect correction (PVC) algorithms in brain PET is largely dependent on the

  6. The unfolding effects on the protein hydration shell and partial molar volume: a computational study.

    Science.gov (United States)

    Del Galdo, Sara; Amadei, Andrea

    2016-10-12

    In this paper we apply the computational analysis recently proposed by our group to characterize the solvation properties of a native protein in aqueous solution, and to four model aqueous solutions of globular proteins in their unfolded states thus characterizing the protein unfolded state hydration shell and quantitatively evaluating the protein unfolded state partial molar volumes. Moreover, by using both the native and unfolded protein partial molar volumes, we obtain the corresponding variations (unfolding partial molar volumes) to be compared with the available experimental estimates. We also reconstruct the temperature and pressure dependence of the unfolding partial molar volume of Myoglobin dissecting the structural and hydration effects involved in the process.

  7. SPAM-assisted partial volume correction algorithm for PET

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2000-07-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38{+-}6%, while those of hippocampus and amygdala by 4{+-}3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images.

  8. SPAM-assisted partial volume correction algorithm for PET

    International Nuclear Information System (INIS)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul

    2000-01-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38±6%, while those of hippocampus and amygdala by 4±3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images

  9. Analysis of Partial Volume Effects on Arterial Input Functions Using Gradient Echo: A Simulation Study

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Mikkelsen, Irene Klærke; Pedersen, Michael

    2009-01-01

    of an AIF voxel including the relaxation properties of blood and tissue. Artery orientations parallel and perpendicular to the main magnetic field were investigated and AIF voxels were modeled to either include or be situated close to a large artery. The impact of partial volume effects on quantitative...... perfusion metrics was investigated for the gradient echo pulse sequence at 1.5 T and 3.0 T. It is shown that the tissue contribution broadens and introduces fluctuations in the AIF. Furthermore, partial volume effects bias perfusion metrics in a nonlinear fashion, compromising quantitative perfusion...

  10. Apparent CBF decrease with normal aging due to partial volume effects: MR-based partial volume correction on CBF SPECT.

    Science.gov (United States)

    Inoue, Kentaro; Ito, Hiroshi; Goto, Ryoi; Nakagawa, Manabu; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi

    2005-06-01

    Several studies using single photon emission tomography (SPECT) have shown changes in cerebral blood flow (CBF) with age, which were associated with partial volume effects by some authors. Some studies have also demonstrated gender-related differences in CBF. The present study aimed to examine age and gender effects on CBF SPECT images obtained using the 99mTc-ethyl cysteinate dimer and a SPECT scanner, before and after partial volume correction (PVC) using magnetic resonance (MR) imaging. Forty-four healthy subjects (29 males and 15 females; age range, 27-64 y; mean age, 50.0 +/- 9.8 y) participated. Each MR image was segmented to yield grey and white matter images and coregistered to a corresponding SPECT image, followed by convolution to approximate the SPECT spatial resolution. PVC-SPECT images were produced using the convoluted grey matter MR (GM-MR) and white matter MR images. The age and gender effects were assessed using SPM99. Decreases with age were detected in the anterolateral prefrontal cortex and in areas along the lateral sulcus and the lateral ventricle, bilaterally, in the GM-MR images and the SPECT images. In the PVC-SPECT images, decreases in CBF in the lateral prefrontal cortex lost their statistical significance. Decreases in CBF with age found along the lateral sulcus and the lateral ventricle, on the other hand, remained statistically significant, but observation of the spatially normalized MR images suggests that these findings are associated with the dilatation of the lateral sulcus and lateral ventricle, which was not completely compensated for by the spatial normalization procedure. Our present study demonstrated that age effects on CBF in healthy subjects could reflect morphological differences with age in grey matter.

  11. Finite-volume and partial quenching effects in the magnetic polarizability of the neutron

    Science.gov (United States)

    Hall, J. M. M.; Leinweber, D. B.; Young, R. D.

    2014-03-01

    There has been much progress in the experimental measurement of the electric and magnetic polarizabilities of the nucleon. Similarly, lattice QCD simulations have recently produced dynamical QCD results for the magnetic polarizability of the neutron approaching the chiral regime. In order to compare the lattice simulations with experiment, calculation of partial quenching and finite-volume effects is required prior to an extrapolation in quark mass to the physical point. These dependencies are described using chiral effective field theory. Corrections to the partial quenching effects associated with the sea-quark-loop electric charges are estimated by modeling corrections to the pion cloud. These are compared to the uncorrected lattice results. In addition, the behavior of the finite-volume corrections as a function of pion mass is explored. Box sizes of approximately 7 fm are required to achieve a result within 5% of the infinite-volume result at the physical pion mass. A variety of extrapolations are shown at different box sizes, providing a benchmark to guide future lattice QCD calculations of the magnetic polarizabilities. A relatively precise value for the physical magnetic polarizability of the neutron is presented, βn=1.93(11)stat(11)sys×10-4 fm3, which is in agreement with current experimental results.

  12. Partial molar volumes of hydrogen and deuterium in niobium and vanadium

    International Nuclear Information System (INIS)

    Herro, H.M.

    1979-01-01

    Lattice dilation studies and direct pressure experiments gave comparable values for the partial molar volumes of hydrogen and deuterium in niobium and vanadium. Small isotope effects in the partial molar volume of hydrogen were measured in both metals by the differential isotope method. Hydrogen had a larger partial molar volume than deuterium in niobium, but the reverse was true in vanadium. The isotope effect measured in niobium can be represented as being due to the larger amplitude of vibration of the hydrogen atom than the deuterium atom in the metal lattice. Since hydrogen has a larger mean displacement from the equilibrium position than does deuterium, the average force hydrogen exerts on the metal atoms is greater than the force deuterium exerts. The isotope effect in vanadium is likely a result of anharmonic effects in the lattice and local vibrational modes

  13. Quantitative analysis of CT brain images: a statistical model incorporating partial volume and beam hardening effects

    International Nuclear Information System (INIS)

    McLoughlin, R.F.; Ryan, M.V.; Heuston, P.M.; McCoy, C.T.; Masterson, J.B.

    1992-01-01

    The purpose of this study was to construct and evaluate a statistical model for the quantitative analysis of computed tomographic brain images. Data were derived from standard sections in 34 normal studies. A model representing the intercranial pure tissue and partial volume areas, with allowance for beam hardening, was developed. The average percentage error in estimation of areas, derived from phantom tests using the model, was 28.47%. We conclude that our model is not sufficiently accurate to be of clinical use, even though allowance was made for partial volume and beam hardening effects. (author)

  14. White matter atlas of the human spinal cord with estimation of partial volume effect.

    Science.gov (United States)

    Lévy, S; Benhamou, M; Naaman, C; Rainville, P; Callot, V; Cohen-Adad, J

    2015-10-01

    Template-based analysis has proven to be an efficient, objective and reproducible way of extracting relevant information from multi-parametric MRI data. Using common atlases, it is possible to quantify MRI metrics within specific regions without the need for manual segmentation. This method is therefore free from user-bias and amenable to group studies. While template-based analysis is common procedure for the brain, there is currently no atlas of the white matter (WM) spinal pathways. The goals of this study were: (i) to create an atlas of the white matter tracts compatible with the MNI-Poly-AMU template and (ii) to propose methods to quantify metrics within the atlas that account for partial volume effect. The WM atlas was generated by: (i) digitalizing an existing WM atlas from a well-known source (Gray's Anatomy), (ii) registering this atlas to the MNI-Poly-AMU template at the corresponding slice (C4 vertebral level), (iii) propagating the atlas throughout all slices of the template (C1 to T6) using regularized diffeomorphic transformations and (iv) computing partial volume values for each voxel and each tract. Several approaches were implemented and validated to quantify metrics within the atlas, including weighted-average and Gaussian mixture models. Proof-of-concept application was done in five subjects for quantifying magnetization transfer ratio (MTR) in each tract of the atlas. The resulting WM atlas showed consistent topological organization and smooth transitions along the rostro-caudal axis. The median MTR across tracts was 26.2. Significant differences were detected across tracts, vertebral levels and subjects, but not across laterality (right-left). Among the different tested approaches to extract metrics, the maximum a posteriori showed highest performance with respect to noise, inter-tract variability, tract size and partial volume effect. This new WM atlas of the human spinal cord overcomes the biases associated with manual delineation and partial

  15. Partial Molar Volume of Methanol in Water: Effect of Polarizability

    Czech Academy of Sciences Publication Activity Database

    Moučka, F.; Nezbeda, Ivo

    2009-01-01

    Roč. 74, č. 4 (2009), s. 559-563 ISSN 0010-0765 R&D Projects: GA AV ČR IAA400720802 Institutional research plan: CEZ:AV0Z40720504 Keywords : water–methanol mixtures * partial molar volume * polarizability Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.856, year: 2009

  16. Partial molar volumes of hydrogen and deuterium in niobium, vanadium, and tantalum

    International Nuclear Information System (INIS)

    Peterson, D.T.; Herro, H.M.

    1983-01-01

    The partial molar volumes of hydrogen and deuterium were measured in vanadium, niobium, and tantalum by a differential pressure technique. One-half of an electrolytically charged sample plat was compressed between hardened steel blocks in a hydraulic press. The activity of hydrogen in the hig pressure region was raised and caused hydrogen to diffuse into the low pressure region. The partia molar volume was calculated from the ratio of the hydrogen concentrations in the high and low pressure regions of the sample. Small isotope effects were found in the partial molar volume. Hydrogen had the larger volume in niobium and tantalum, but the reverse was true in vanadium

  17. Generalized Partial Volume

    DEFF Research Database (Denmark)

    Darkner, Sune; Sporring, Jon

    2011-01-01

    Mutual Information (MI) and normalized mutual information (NMI) are popular choices as similarity measure for multimodal image registration. Presently, one of two approaches is often used for estimating these measures: The Parzen Window (PW) and the Generalized Partial Volume (GPV). Their theoret...... of view as well as w.r.t. computational complexity. Finally, we present algorithms for both approaches for NMI which is comparable in speed to Sum of Squared Differences (SSD), and we illustrate the differences between PW and GPV on a number of registration examples....

  18. Partial molar volumes of proteins: amino acid side-chain contributions derived from the partial molar volumes of some tripeptides over the temperature range 10-90 degrees C.

    Science.gov (United States)

    Häckel, M; Hinz, H J; Hedwig, G R

    1999-11-15

    The partial molar volumes of tripeptides of sequence glycyl-X-glycine, where X is one of the amino acids alanine, leucine, threonine, glutamine, phenylalanine, histidine, cysteine, proline, glutamic acid, and arginine, have been determined in aqueous solution over the temperature range 10-90 degrees C using differential scanning densitometry . These data, together with those reported previously, have been used to derive the partial molar volumes of the side-chains of all 20 amino acids. The side-chain volumes are critically compared with literature values derived using partial molar volumes for alternative model compounds. The new amino acid side-chain volumes, along with that for the backbone glycyl group, were used to calculate the partial specific volumes of several proteins in aqueous solution. The results obtained are compared with those observed experimentally. The new side-chain volumes have also been used to re-determine residue volume changes upon protein folding.

  19. When structure affects function--the need for partial volume effect correction in functional and resting state magnetic resonance imaging studies.

    Science.gov (United States)

    Dukart, Juergen; Bertolino, Alessandro

    2014-01-01

    Both functional and also more recently resting state magnetic resonance imaging have become established tools to investigate functional brain networks. Most studies use these tools to compare different populations without controlling for potential differences in underlying brain structure which might affect the functional measurements of interest. Here, we adapt a simulation approach combined with evaluation of real resting state magnetic resonance imaging data to investigate the potential impact of partial volume effects on established functional and resting state magnetic resonance imaging analyses. We demonstrate that differences in the underlying structure lead to a significant increase in detected functional differences in both types of analyses. Largest increases in functional differences are observed for highest signal-to-noise ratios and when signal with the lowest amount of partial volume effects is compared to any other partial volume effect constellation. In real data, structural information explains about 25% of within-subject variance observed in degree centrality--an established resting state connectivity measurement. Controlling this measurement for structural information can substantially alter correlational maps obtained in group analyses. Our results question current approaches of evaluating these measurements in diseased population with known structural changes without controlling for potential differences in these measurements.

  20. Effect of Molecular Size of Solutes on Their Partial Molar Volumes in Supercritical n-Pentane

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The densities of n-pentane, methane-n-pentane, propane-n-pentane, n-heptane-n-pentane, and n-decane-n-pentane binary mixtures were determined at 476.5K in the pressure range from 2 to 5 MPa. The partial molar volumes of the solutes in n-pentane were calculated using the density data. It was found that the partial molar volumes of methane and propane are positive , while those of n-heptane and n-decane are negative.

  1. Different partial volume correction methods lead to different conclusions

    DEFF Research Database (Denmark)

    Greve, Douglas N; Salat, David H; Bowen, Spencer L

    2016-01-01

    A cross-sectional group study of the effects of aging on brain metabolism as measured with (18)F-FDG-PET was performed using several different partial volume correction (PVC) methods: no correction (NoPVC), Meltzer (MZ), Müller-Gärtner (MG), and the symmetric geometric transfer matrix (SGTM) usin...

  2. Partial molar volume of n-alcohols at infinite dilution in water calculated by means of scaled particle theory.

    Science.gov (United States)

    Graziano, Giuseppe

    2006-04-07

    The partial molar volume of n-alcohols at infinite dilution in water is smaller than the molar volume in the neat liquid phase. It is shown that the formula for the partial molar volume at infinite dilution obtained from the scaled particle theory equation of state for binary hard sphere mixtures is able to reproduce in a satisfactory manner the experimental data over a large temperature range. This finding implies that the packing effects play the fundamental role in determining the partial molar volume at infinite dilution in water also for solutes, such as n-alcohols, forming H bonds with water molecules. Since the packing effects in water are largely related to the small size of its molecules, the latter feature is the ultimate cause of the decrease in partial molar volume associated with the hydrophobic effect.

  3. Parsing partial molar volumes of small molecules: a molecular dynamics study.

    Science.gov (United States)

    Patel, Nisha; Dubins, David N; Pomès, Régis; Chalikian, Tigran V

    2011-04-28

    We used molecular dynamics (MD) simulations in conjunction with the Kirkwood-Buff theory to compute the partial molar volumes for a number of small solutes of various chemical natures. We repeated our computations using modified pair potentials, first, in the absence of the Coulombic term and, second, in the absence of the Coulombic and the attractive Lennard-Jones terms. Comparison of our results with experimental data and the volumetric results of Monte Carlo simulation with hard sphere potentials and scaled particle theory-based computations led us to conclude that, for small solutes, the partial molar volume computed with the Lennard-Jones potential in the absence of the Coulombic term nearly coincides with the cavity volume. On the other hand, MD simulations carried out with the pair interaction potentials containing only the repulsive Lennard-Jones term produce unrealistically large partial molar volumes of solutes that are close to their excluded volumes. Our simulation results are in good agreement with the reported schemes for parsing partial molar volume data on small solutes. In particular, our determined interaction volumes() and the thickness of the thermal volume for individual compounds are in good agreement with empirical estimates. This work is the first computational study that supports and lends credence to the practical algorithms of parsing partial molar volume data that are currently in use for molecular interpretations of volumetric data.

  4. Hitchhiker'S Guide to Voxel Segmentation for Partial Volume Correction of in Vivo Magnetic Resonance Spectroscopy

    Directory of Open Access Journals (Sweden)

    Scott Quadrelli

    2016-01-01

    Full Text Available Partial volume effects have the potential to cause inaccuracies when quantifying metabolites using proton magnetic resonance spectroscopy (MRS. In order to correct for cerebrospinal fluid content, a spectroscopic voxel needs to be segmented according to different tissue contents. This article aims to detail how automated partial volume segmentation can be undertaken and provides a software framework for researchers to develop their own tools. While many studies have detailed the impact of partial volume correction on proton magnetic resonance spectroscopy quantification, there is a paucity of literature explaining how voxel segmentation can be achieved using freely available neuroimaging packages.

  5. Partial and apparent molar volumes of aqueous solutions of the 1:1 type electrolytes

    International Nuclear Information System (INIS)

    Klugman, I.Yu.

    2002-01-01

    Formulas for calculating partial and apparent molar volumes of MX (M=Li-Cs; X = Cl-I) electrolyte aqueous solutions in a wide range of concentrations from 0 to 4 mol/kg with error not in excess of 0.05% are suggested. It is shown that the previously employed formulas for calculating partial molar volumes of electrolytes give false indications of mutual effect of ions and actually they are fit solely for very small concentrations [ru

  6. Isotropic non-white matter partial volume effects in constrained spherical deconvolution

    Directory of Open Access Journals (Sweden)

    Timo eRoine

    2014-03-01

    Full Text Available Diffusion-weighted (DW magnetic resonance imaging (MRI is a noninvasive imaging method, which can be used to investigate neural tracts in the white matter (WM of the brain. Significant partial volume effects (PVE are present in the DW signal due to relatively large voxel sizes. These PVEs can be caused by both non-WM tissue, such as gray matter (GM and cerebrospinal fluid (CSF, and by multiple nonparallel WM fiber populations. High angular resolution diffusion imaging (HARDI methods have been developed to correctly characterize complex WM fiber configurations, but to date, many of the HARDI methods do not account for non-WM PVEs. In this work, we investigated the isotropic PVEs caused by non-WM tissue in WM voxels on fiber orientations extracted with constrained spherical deconvolution (CSD. Experiments were performed on simulated and real DW-MRI data. In particular, simulations were performed to demonstrate the effects of varying the diffusion weightings, signal-to-noise ratios (SNR, fiber configurations, and tissue fractions.Our results show that the presence of non-WM tissue signal causes a decrease in the precision of the detected fiber orientations and an increase in the detection of false peaks in CSD. We estimated 35-50 % of WM voxels to be affected by non-WM PVEs. For HARDI sequences, which typically have a relatively high degree of diffusion weighting, these adverse effects are most pronounced in voxels with GM PVEs. The non-WM PVEs become severe with 50 % GM volume for maximum spherical harmonics orders of 8 and below, and already with 25 % GM volume for higher orders. In addition, a low diffusion weighting or SNR increases the effects. The non-WM PVEs may cause problems in connectomics, where reliable fiber tracking at the WM-GM interface is especially important. We suggest acquiring data with high diffusion-weighting 2500-3000 s/mm2, reasonable SNR (~30 and using lower SH orders in GM contaminated regions to minimize the non-WM PVEs

  7. Isotropic non-white matter partial volume effects in constrained spherical deconvolution.

    Science.gov (United States)

    Roine, Timo; Jeurissen, Ben; Perrone, Daniele; Aelterman, Jan; Leemans, Alexander; Philips, Wilfried; Sijbers, Jan

    2014-01-01

    Diffusion-weighted (DW) magnetic resonance imaging (MRI) is a non-invasive imaging method, which can be used to investigate neural tracts in the white matter (WM) of the brain. Significant partial volume effects (PVEs) are present in the DW signal due to relatively large voxel sizes. These PVEs can be caused by both non-WM tissue, such as gray matter (GM) and cerebrospinal fluid (CSF), and by multiple non-parallel WM fiber populations. High angular resolution diffusion imaging (HARDI) methods have been developed to correctly characterize complex WM fiber configurations, but to date, many of the HARDI methods do not account for non-WM PVEs. In this work, we investigated the isotropic PVEs caused by non-WM tissue in WM voxels on fiber orientations extracted with constrained spherical deconvolution (CSD). Experiments were performed on simulated and real DW-MRI data. In particular, simulations were performed to demonstrate the effects of varying the diffusion weightings, signal-to-noise ratios (SNRs), fiber configurations, and tissue fractions. Our results show that the presence of non-WM tissue signal causes a decrease in the precision of the detected fiber orientations and an increase in the detection of false peaks in CSD. We estimated 35-50% of WM voxels to be affected by non-WM PVEs. For HARDI sequences, which typically have a relatively high degree of diffusion weighting, these adverse effects are most pronounced in voxels with GM PVEs. The non-WM PVEs become severe with 50% GM volume for maximum spherical harmonics orders of 8 and below, and already with 25% GM volume for higher orders. In addition, a low diffusion weighting or SNR increases the effects. The non-WM PVEs may cause problems in connectomics, where reliable fiber tracking at the WM-GM interface is especially important. We suggest acquiring data with high diffusion-weighting 2500-3000 s/mm(2), reasonable SNR (~30) and using lower SH orders in GM contaminated regions to minimize the non-WM PVEs in CSD.

  8. Quantifying [{sup 18}F]fluorodeoxyglucose uptake in the arterial wall: the effects of dual time-point imaging and partial volume effect correction

    Energy Technology Data Exchange (ETDEWEB)

    Blomberg, Bjoern A. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark); Bashyam, Arjun; Ramachandran, Abhinay; Gholami, Saeid; Houshmand, Sina; Salavati, Ali; Werner, Tom; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); University of Groningen, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen (Netherlands)

    2015-08-15

    The human arterial wall is smaller than the spatial resolution of current positron emission tomographs. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake. We evaluated the impact of a novel method for partial volume effect (PVE) correction with contrast-enhanced CT (CECT) assistance on quantification of arterial wall {sup 18}F-FDG uptake at different imaging time-points. Ten subjects were assessed by CECT imaging and dual time-point PET/CT imaging at approximately 60 and 180 min after {sup 18}F-FDG administration. For both time-points, uptake of {sup 18}F-FDG was determined in the aortic wall by calculating the blood pool-corrected maximum standardized uptake value (cSUV{sub MAX}) and cSUV{sub MEAN}. The PVE-corrected SUV{sub MEAN} (pvcSUV{sub MEAN}) was also calculated using {sup 18}F-FDG PET/CT and CECT images. Finally, corresponding target-to-background ratios (TBR) were calculated. At 60 min, pvcSUV{sub MEAN} was on average 3.1 times greater than cSUV{sub MAX} (P <.0001) and 8.5 times greater than cSUV{sub MEAN} (P <.0001). At 180 min, pvcSUV{sub MEAN} was on average 2.6 times greater than cSUV{sub MAX} (P <.0001) and 6.6 times greater than cSUV{sub MEAN} (P <.0001). This study demonstrated that CECT-assisted PVE correction significantly influences quantification of arterial wall {sup 18}F-FDG uptake. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake with PET. (orig.)

  9. Computing the partial volume of pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wiencke, Bent [Nestle USA, Corporate Engineering, 800 N. Brand Blvd, Glendale, CA 91203 (United States)

    2010-06-15

    The computation of the partial and total volume of pressure vessels with various type of head profiles requires detailed knowledge of the head profile geometry. Depending on the type of head profile the derivation of the equations can become very complex and the calculation process cumbersome. Certain head profiles require numerical methods to obtain the partial volume, which for most application is beyond the scope of practicability. This paper suggests a unique method that simplifies the calculation procedure for the various types of head profiles by using one common set of equations without the need for numerical or complex computation methods. For ease of use, all equations presented in this paper are summarized in a single table format for horizontal and vertical vessels. (author)

  10. Partial molar volumes and partial molar adiabatic compressibilities of a short chain perfluorosurfactant: Sodium heptafluorobutyrate in aqueous solutions at different temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, Elena [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Ruso, Juan M. [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain)]. E-mail: faruso@usc.es; Prieto, Gerardo [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Sarmiento, Felix [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain)

    2005-12-15

    Density and ultrasound measurements of sodium heptafluorobutyrate in aqueous solutions at T = (283.15, 288.15, 293.15, 298.15, 303.15, 308.15, 313.15, 318.15, and 323.15) K have been obtained. From these results partial molar volumes and isentropic partial molar adiabatic compressibilities were calculated. Deviations from the Debye-Hueckel limiting law provide evidence for limited association at lower concentrations. The change of the partial molar volume and isentropic partial molar adiabatic compressibility upon aggregation was calculated. Variations of the change of partial molar volumes and isentropic partial molar adiabatic compressibility upon aggregation are discussed in terms of temperature.

  11. Partial molar volumes and partial molar adiabatic compressibilities of a short chain perfluorosurfactant: Sodium heptafluorobutyrate in aqueous solutions at different temperatures

    International Nuclear Information System (INIS)

    Blanco, Elena; Ruso, Juan M.; Prieto, Gerardo; Sarmiento, Felix

    2005-01-01

    Density and ultrasound measurements of sodium heptafluorobutyrate in aqueous solutions at T = (283.15, 288.15, 293.15, 298.15, 303.15, 308.15, 313.15, 318.15, and 323.15) K have been obtained. From these results partial molar volumes and isentropic partial molar adiabatic compressibilities were calculated. Deviations from the Debye-Hueckel limiting law provide evidence for limited association at lower concentrations. The change of the partial molar volume and isentropic partial molar adiabatic compressibility upon aggregation was calculated. Variations of the change of partial molar volumes and isentropic partial molar adiabatic compressibility upon aggregation are discussed in terms of temperature

  12. Partial Molar Volumes of Aqua Ions from First Principles.

    Science.gov (United States)

    Wiktor, Julia; Bruneval, Fabien; Pasquarello, Alfredo

    2017-08-08

    Partial molar volumes of ions in water solution are calculated through pressures obtained from ab initio molecular dynamics simulations. The correct definition of pressure in charged systems subject to periodic boundary conditions requires access to the variation of the electrostatic potential upon a change of volume. We develop a scheme for calculating such a variation in liquid systems by setting up an interface between regions of different density. This also allows us to determine the absolute deformation potentials for the band edges of liquid water. With the properly defined pressures, we obtain partial molar volumes of a series of aqua ions in very good agreement with experimental values.

  13. Effect of partial volume correction on muscarinic cholinergic receptor imaging with single-photon emission tomography in patients with temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Weckesser, M.; Ziemons, K.; Griessmeier, M.; Sonnenberg, F.; Langen, K.J.; Mueller-Gaertner, H.W.; Hufnagel, A.; Elger, C.E.; Hacklaender, T.; Holschbach, M.

    1997-01-01

    Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [ 123 I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration. (orig.). With 2 figs., 2 tabs

  14. The partial molar volume of BeSO4 in aqueous solutions

    International Nuclear Information System (INIS)

    Kuschel, F.; Seidel, J.

    1981-01-01

    The density of aqueous solutions of BeSO 4 has been measured as a function of the mole fraction in the range of 0.02487 x 10 -2 to 6.3082 x 10 -2 . From the results obtained the molar volume and partial molar volume have been calculated and the limiting value of the partial molar volume for Be 2+ was extrapolated in accordance with the Debye-Hueckel law

  15. Note: Nonpolar solute partial molar volume response to attractive interactions with water

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Steven M.; Ashbaugh, Henry S., E-mail: hanka@tulane.edu [Department of Chemical and Biomolecular Engineering, Tulane University, New Orleans, Louisiana 70118 (United States)

    2014-01-07

    The impact of attractive interactions on the partial molar volumes of methane-like solutes in water is characterized using molecular simulations. Attractions account for a significant 20% volume drop between a repulsive Weeks-Chandler-Andersen and full Lennard-Jones description of methane interactions. The response of the volume to interaction perturbations is characterized by linear fits to our simulations and a rigorous statistical thermodynamic expression for the derivative of the volume to increasing attractions. While a weak non-linear response is observed, an average effective slope accurately captures the volume decrease. This response, however, is anticipated to become more non-linear with increasing solute size.

  16. Note: Nonpolar solute partial molar volume response to attractive interactions with water.

    Science.gov (United States)

    Williams, Steven M; Ashbaugh, Henry S

    2014-01-07

    The impact of attractive interactions on the partial molar volumes of methane-like solutes in water is characterized using molecular simulations. Attractions account for a significant 20% volume drop between a repulsive Weeks-Chandler-Andersen and full Lennard-Jones description of methane interactions. The response of the volume to interaction perturbations is characterized by linear fits to our simulations and a rigorous statistical thermodynamic expression for the derivative of the volume to increasing attractions. While a weak non-linear response is observed, an average effective slope accurately captures the volume decrease. This response, however, is anticipated to become more non-linear with increasing solute size.

  17. Partial drift volume due to a self-propelled swimmer

    Science.gov (United States)

    Chisholm, Nicholas G.; Khair, Aditya S.

    2018-01-01

    We assess the ability of a self-propelled swimmer to displace a volume of fluid that is large compared to its own volume via the mechanism of partial drift. The swimmer performs rectilinear locomotion in an incompressible, unbounded Newtonian fluid. The partial drift volume D is the volume of fluid enclosed between the initial and final profiles of an initially flat circular disk of marked fluid elements; the disk is initially aligned perpendicular to the direction of locomotion and subsequently distorted due to the passage of the swimmer, which travels a finite distance. To focus on the possibility of large-scale drift, we model the swimmer simply as a force dipole aligned with the swimming direction. At zero Reynolds number (Re =0 ), we demonstrate that D grows without limit as the radius of the marked fluid disk h is made large, indicating that a swimmer at Re =0 can generate a partial drift volume much larger than its own volume. Next, we consider a steady swimmer at small Re , which is modeled as the force-dipole solution to Oseen's equation. Here, we find that D no longer diverges with h , which is due to inertial screening of viscous forces, and is effectively proportional to the magnitude of the force dipole exerted by the swimmer. The validity of this result is extended to Re ≥O (1 ) —the realm of intermediate-Re swimmers such as copepods—by taking advantage of the fact that, in this case, the flow is also described by Oseen's equations at distances much larger than the characteristic linear dimension of the swimmer. Next, we utilize an integral momentum balance to demonstrate that our analysis for a steady inertial swimmer also holds, in a time-averaged sense, for an unsteady swimmer that does not experience a net acceleration over a stroke cycle. Finally, we use experimental data to estimate D for a few real swimmers. Interestingly, we find that D depends heavily on the kinematics of swimming, and, in certain cases, D can be significantly greater

  18. Evaluation of the reconstruction method and effect of partial volume in brain scintiscanning

    International Nuclear Information System (INIS)

    Pinheiro, Monica Araujo

    2016-01-01

    Alzheimer's disease is a neurodegenerative disorder, on which occurs a progressive and irreversible destruction of neurons. According to the World Health Organization (WHO) 35.6 million people are living with dementia, being recommended that governments prioritize early diagnosis techniques. Laboratory and psychological tests for cognitive assessment are conducted and further complemented by neurological imaging from nuclear medicine exams in order to establish an accurate diagnosis. The image quality evaluation and reconstruction process effects are important tools in clinical routine. In the present work, these quality parameters were studied, and the effects of partial volume (PVE) for lesions of different sizes and geometries that are attributed to the limited resolution of the equipment. In dementia diagnosis, this effect can be confused with intake losses due to cerebral cortex atrophy. The evaluation was conducted by two phantoms of different shapes as suggested by (a) American College of Radiology (ACR) and (b) National Electrical Manufacturers Association (NEMA) for Contrast, Contrast-to-Noise Ratio (CNR) and Recovery Coefficient (RC) calculation versus lesions shape and size. Technetium-99m radionuclide was used in a local brain scintigraphy protocol, for proportions lesion to background of 2:1, 4:1, 6:1, 8:1 and 10:1. Fourteen reconstruction methods were used for each concentration applying different filters and algorithms. Before the analysis of all image properties, the conclusion is that the predominant effect is the partial volume, leading to errors of measurement of more than 80%. Furthermore, it was demonstrate that the most effective method of reconstruction is FBP with Metz filter, providing better contrast and contrast to noise ratio results. In addition, this method shows the best Recovery Coefficients correction for each lesion. The ACR phantom showed the best results assigned to a more precise reconstruction of a cylinder, which does not

  19. Partial molar volume of proteins studied by the three-dimensional reference interaction site model theory.

    Science.gov (United States)

    Imai, Takashi; Kovalenko, Andriy; Hirata, Fumio

    2005-04-14

    The three-dimensional reference interaction site model (3D-RISM) theory is applied to the analysis of hydration effects on the partial molar volume of proteins. For the native structure of some proteins, the partial molar volume is decomposed into geometric and hydration contributions using the 3D-RISM theory combined with the geometric volume calculation. The hydration contributions are correlated with the surface properties of the protein. The thermal volume, which is the volume of voids around the protein induced by the thermal fluctuation of water molecules, is directly proportional to the accessible surface area of the protein. The interaction volume, which is the contribution of electrostatic interactions between the protein and water molecules, is apparently governed by the charged atomic groups on the protein surface. The polar atomic groups do not make any contribution to the interaction volume. The volume differences between low- and high-pressure structures of lysozyme are also analyzed by the present method.

  20. Reductions in Corpus Callosum Volume Partially Mediate Effects of Prenatal Alcohol Exposure on IQ

    Directory of Open Access Journals (Sweden)

    Stevie C. Biffen

    2018-01-01

    Full Text Available Disproportionate volume reductions in the basal ganglia, corpus callosum (CC and hippocampus have been reported in children with prenatal alcohol exposure (PAE. However, few studies have investigated these reductions in high prevalence communities, such as the Western Cape Province of South Africa, and only one study made use of manual tracing, the gold standard of volumetric analysis. The present study examined the effects of PAE on subcortical neuroanatomy using manual tracing and the relation of volumetric reductions in these regions to IQ and performance on the California Verbal Learning Test-Children's Version (CVLT-C, a list learning task sensitive to PAE. High-resolution T1-weighted images were acquired, using a sequence optimized for morphometric neuroanatomical analysis, on a Siemens 3T Allegra MRI scanner from 71 right-handed, 9- to 11-year-old children [9 fetal alcohol syndrome (FAS, 19 partial FAS (PFAS, 24 non-syndromal heavily exposed (HE and 19 non-exposed controls]. Frequency of maternal drinking was ascertained prospectively during pregnancy using timeline follow-back interviews. PAE was examined in relation to volumes of the CC and left and right caudate nuclei, nucleus accumbens and hippocampi. All structures were manually traced using Multitracer. Higher levels of PAE were associated with reductions in CC volume after adjustment for TIV. Although the effect of PAE on CC was confounded with smoking and lead exposure, additional analyses showed that it was not accounted for by these exposures. Amongst dysmorphic children, smaller CC was associated with poorer IQ and CVLT-C scores and statistically mediated the effect of PAE on IQ. In addition, higher levels of PAE were associated with bilateral volume reductions in caudate nuclei and hippocampi, effects that remained significant after control for TIV, child sex and age, socioeconomic status, maternal smoking during pregnancy, and childhood lead exposure. These data confirm

  1. Standard partial molar volumes of some electrolytes in ethylene carbonate based mixtures

    International Nuclear Information System (INIS)

    Zhao, Yang; Wang, Jianji.; Lu, Hui; Lin, Ruisen

    2004-01-01

    Apparent molar volumes V 2,phi and standard partial molar volumes V 2,phi 0 of LiClO 4 , LiBr and three symmetrical tetraalkylammonium bromides R 4 NBr (R=ethyl, propyl, butyl) have been determined at 298.15 K from precise density measurements in solvent mixtures of ethylene carbonate with tetrahydrofuran (THF), acetonitrile (AN), ethyl acetate (EA) and dimethoxyethane (DME). It is shown that the V 2,phi 0 values of LiClO 4 and LiBr are dependent strongly on the nature of the solvents, whereas the contribution of CH 2 group to the partial molar volume of the tetraalkylammonium salts has nothing to do with the nature of the solvents and the composition of the solvent mixtures. This provided a helpful evidence for the unsolvation of large tetraalkylammonium cations in organic solvents. The results have been discussed from ion-solvent interactions and the dielectric effect of the solvents

  2. Partial volume and aliasing artefacts in helical cone-beam CT

    International Nuclear Information System (INIS)

    Zou Yu; Sidky, Emil Y; Pan, Xiaochuan

    2004-01-01

    A generalization of the quasi-exact algorithms of Kudo et al (2000 IEEE Trans. Med. Imaging 19 902-21) is developed that allows for data acquisition in a 'practical' frame for clinical diagnostic helical, cone-beam computed tomography (CT). The algorithm is investigated using data that model nonlinear partial volume averaging. This investigation leads to an understanding of aliasing artefacts in helical, cone-beam CT image reconstruction. An ad hoc scheme is proposed to mitigate artefacts due to the nonlinear partial volume and aliasing artefacts

  3. Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Kim, Dae Ho; Son, Sang Jun; Mun, Jun Ki; Seo, Seok Jin; Lee, Je Hee

    2016-01-01

    By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change

  4. Partial Volume Effects correction in emission tomography

    International Nuclear Information System (INIS)

    Le Pogam, Adrien

    2010-01-01

    Partial Volume Effects (PVE) designates the blur commonly found in nuclear medicine images and this PhD work is dedicated to their correction with the objectives of qualitative and quantitative improvement of such images. PVE arise from the limited spatial resolution of functional imaging with either Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT). They can be defined as a signal loss in tissues of size similar to the Full Width at Half Maximum (FWHM) of the PSF of the imaging device. In addition, PVE induce activity cross contamination between adjacent structures with different tracer uptakes. This can lead to under or over estimation of the real activity of such analyzed regions. Various methodologies currently exist to compensate or even correct for PVE and they may be classified depending on their place in the processing chain: either before, during or after the image reconstruction process, as well as their dependency on co-registered anatomical images with higher spatial resolution, for instance Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). The voxel-based and post-reconstruction approach was chosen for this work to avoid regions of interest definition and dependency on proprietary reconstruction developed by each manufacturer, in order to improve the PVE correction. Two different contributions were carried out in this work: the first one is based on a multi-resolution methodology in the wavelet domain using the higher resolution details of a co-registered anatomical image associated to the functional dataset to correct. The second one is the improvement of iterative deconvolution based methodologies by using tools such as directional wavelets and curvelets extensions. These various developed approaches were applied and validated using synthetic, simulated and clinical images, for instance with neurology and oncology applications in mind. Finally, as currently available PET/CT scanners incorporate more

  5. Determination of partial molar volumes from free energy perturbation theory†

    Science.gov (United States)

    Vilseck, Jonah Z.; Tirado-Rives, Julian

    2016-01-01

    Partial molar volume is an important thermodynamic property that gives insights into molecular size and intermolecular interactions in solution. Theoretical frameworks for determining the partial molar volume (V°) of a solvated molecule generally apply Scaled Particle Theory or Kirkwood–Buff theory. With the current abilities to perform long molecular dynamics and Monte Carlo simulations, more direct methods are gaining popularity, such as computing V° directly as the difference in computed volume from two simulations, one with a solute present and another without. Thermodynamically, V° can also be determined as the pressure derivative of the free energy of solvation in the limit of infinite dilution. Both approaches are considered herein with the use of free energy perturbation (FEP) calculations to compute the necessary free energies of solvation at elevated pressures. Absolute and relative partial molar volumes are computed for benzene and benzene derivatives using the OPLS-AA force field. The mean unsigned error for all molecules is 2.8 cm3 mol−1. The present methodology should find use in many contexts such as the development and testing of force fields for use in computer simulations of organic and biomolecular systems, as a complement to related experimental studies, and to develop a deeper understanding of solute–solvent interactions. PMID:25589343

  6. Determination of partial molar volumes from free energy perturbation theory.

    Science.gov (United States)

    Vilseck, Jonah Z; Tirado-Rives, Julian; Jorgensen, William L

    2015-04-07

    Partial molar volume is an important thermodynamic property that gives insights into molecular size and intermolecular interactions in solution. Theoretical frameworks for determining the partial molar volume (V°) of a solvated molecule generally apply Scaled Particle Theory or Kirkwood-Buff theory. With the current abilities to perform long molecular dynamics and Monte Carlo simulations, more direct methods are gaining popularity, such as computing V° directly as the difference in computed volume from two simulations, one with a solute present and another without. Thermodynamically, V° can also be determined as the pressure derivative of the free energy of solvation in the limit of infinite dilution. Both approaches are considered herein with the use of free energy perturbation (FEP) calculations to compute the necessary free energies of solvation at elevated pressures. Absolute and relative partial molar volumes are computed for benzene and benzene derivatives using the OPLS-AA force field. The mean unsigned error for all molecules is 2.8 cm(3) mol(-1). The present methodology should find use in many contexts such as the development and testing of force fields for use in computer simulations of organic and biomolecular systems, as a complement to related experimental studies, and to develop a deeper understanding of solute-solvent interactions.

  7. Partial volume effect correction in nuclear medicine: assessment with a mathematical phantom

    International Nuclear Information System (INIS)

    Silva, Murilo Collete da; Pozzo, Lorena

    2009-01-01

    Objective: assessment of Van Cittert partial volume effect correction method in nuclear medicine images, with a mathematical phantom. Material and method: we simulated an image of four circular sources of different diameters and intensity of 255 per pixel. The iterative algorithm was applied with 20 iterations and α = 1. We obtained the maximum and average counts on the entire image and in regions of interest placed on each of the sources. We also extracted count profiles plotted along the diameter of each of the sources. Results: the local convergence depends on the size of the source studied: the smaller the source, the greater the number of iterations required. It also depends on the information extracted: the use of average counts provides more homogeneous results than the maximum count. There is a significant improvement in image contrast. Conclusion: this study showed the possibility of qualitative and quantitative improvement in applying the bidimensional iterative Van Cittert method to images of simple geometry. (author)

  8. Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Son, Sang Jun; Mun, Jun Ki; Seo, Seok Jin; Lee, Je Hee [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2016-06-15

    By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change.

  9. Kalisphera: an analytical tool to reproduce the partial volume effect of spheres imaged in 3D

    International Nuclear Information System (INIS)

    Tengattini, Alessandro; Andò, Edward

    2015-01-01

    In experimental mechanics, where 3D imaging is having a profound effect, spheres are commonly adopted for their simplicity and for the ease of their modeling. In this contribution we develop an analytical tool, ‘kalisphera’, to produce 3D raster images of spheres including their partial volume effect. This allows us to evaluate the metrological performance of existing image-based measurement techniques (knowing a priori the ground truth). An advanced application of ‘kalisphera’ is developed here to identify and accurately characterize spheres in real 3D x-ray tomography images with the objective of improving trinarization and contact detection. The effect of the common experimental imperfections is assessed and the overall performance of the tool tested on real images. (paper)

  10. Correction for Partial Volume Effect Is a Must, Not a Luxury, to Fully Exploit the Potential of Quantitative PET Imaging in Clinical Oncology

    DEFF Research Database (Denmark)

    Alavi, Abass; Werner, Thomas J; Høilund-Carlsen, Poul Flemming

    2018-01-01

    The partial volume effect (PVE) is considered as one of the major degrading factors impacting image quality and hampering the accuracy of quantitative PET imaging in clinical oncology. This effect is the consequence of the limited spatial resolution of whole-body PET scanners, which results in bl...

  11. Partial molar volume of anionic polyelectrolytes in aqueous solution.

    Science.gov (United States)

    Salamanca, Constain; Contreras, Martín; Gamboa, Consuelo

    2007-05-15

    In this work the partial molar volumes (V) of different anionic polyelectrolytes and hydrophobically modified polyelectrolytes (PHM) were measured. Polymers like polymaleic acid-co-styrene, polymaleic acid-co-1-olefin, polymaleic acid-co-vinyl-2-pyrrolidone, and polyacrylic acid (abbreviated as MAS-n, PA-n-K2, AMVP, and PAA, respectively) were employed. These materials were investigated by density measurements in highly dilute aqueous solutions. The molar volume results allow us to discuss the effect of the carboxylic groups and the contributions from the comonomeric principal chain. The PAA presents the smaller V, while the largest V value was for AMVP. The V of PHM shows a linear relationship with the number of methylene groups in the lateral chain. It is found that the magnitude of the contribution per methylene group decreases as the hydrophobic character of the environment increases.

  12. Infinite dilution partial molar volumes of platinum(II) 2,4-pentanedionate in supercritical carbon dioxide.

    Science.gov (United States)

    Kong, Chang Yi; Siratori, Tomoya; Funazukuri, Toshitaka; Wang, Guosheng

    2014-10-03

    The effects of temperature and density on retention of platinum(II) 2,4-pentanedionate in supercritical fluid chromatography were investigated at temperatures of 308.15-343.15K and pressure range from 8 to 40MPa by the chromatographic impulse response method with curve fitting. The retention factors were utilized to derive the infinite dilution partial molar volumes of platinum(II) 2,4-pentanedionate in supercritical carbon dioxide. The determined partial molar volumes were small and positive at high pressures but exhibited very large and negative values in the highly compressible near critical region of carbon dioxide. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. The partial volume effect in the quantification of 1H magnetic resonance spectroscopy in Alzheimer's disease and aging.

    Science.gov (United States)

    Mato Abad, Virginia; Quirós, Alicia; García-Álvarez, Roberto; Loureiro, Javier Pereira; Alvarez-Linera, Juan; Frank, Ana; Hernández-Tamames, Juan Antonio

    2014-01-01

    1H-MRS variability increases due to normal aging and also as a result of atrophy in grey and white matter caused by neurodegeneration. In this work, an automatic process was developed to integrate data from spectra and high-resolution anatomical images to quantify metabolites, taking into account tissue partial volumes within the voxel of interest avoiding additional spectra acquisitions required for partial volume correction. To evaluate this method, we use a cohort of 135 subjects (47 male and 88 female, aged between 57 and 99 years) classified into 4 groups: 38 healthy participants, 20 amnesic mild cognitive impairment patients, 22 multi-domain mild cognitive impairment patients, and 55 Alzheimer's disease patients. Our findings suggest that knowing the voxel composition of white and grey matter and cerebrospinal fluid is necessary to avoid partial volume variations in a single-voxel study and to decrease part of the variability found in metabolites quantification, particularly in those studies involving elder patients and neurodegenerative diseases. The proposed method facilitates the use of 1H-MRS techniques in statistical studies in Alzheimer's disease, because it provides more accurate quantitative measurements, reduces the inter-subject variability, and improves statistical results when performing group comparisons.

  14. Partial volume correction in SPECT reconstruction with OSEM

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, Kjell, E-mail: k.erlandsson@ucl.ac.uk [Institute of Nuclear Medicine, University College London and University College London Hospital, London NW1 2BU (United Kingdom); Thomas, Ben; Dickson, John; Hutton, Brian F. [Institute of Nuclear Medicine, University College London and University College London Hospital, London NW1 2BU (United Kingdom)

    2011-08-21

    SPECT images suffer from poor spatial resolution, which leads to partial volume effects due to cross-talk between different anatomical regions. By utilising high-resolution structural images (CT or MRI) it is possible to compensate for these effects. Traditional partial volume correction (PVC) methods suffer from various limitations, such as correcting a single region only, returning only regional mean values, or assuming a stationary point spread function (PSF). We recently presented a novel method in which PVC was combined with the reconstruction process in order to take into account the distance dependent PSF in SPECT, which was based on filtered backprojection (FBP) reconstruction. We now present a new method based on the iterative OSEM algorithm, which has advantageous noise properties compared to FBP. We have applied this method to a series of 10 brain SPECT studies performed on healthy volunteers using the DATSCAN tracer. T1-weighted MRI images were co-registered to the SPECT data and segmented into 33 anatomical regions. The SPECT data were reconstructed using OSEM, and PVC was applied in the projection domain at each iteration. The correction factors were calculated by forward projection of a piece-wise constant image, generated from the segmented MRI. Images were also reconstructed using FBP and standard OSEM with and without resolution recovery (RR) for comparison. The images were evaluated in terms of striatal contrast and regional variability (CoV). The mean striatal contrast obtained with OSEM, OSEM-RR and OSEM-PVC relative to FBP were 1.04, 1.42 and 1.53, respectively, and the mean striatal CoV values are 1.05, 1.53, 1.07. Both OSEM-RR and OSEM-PVC results in images with significantly higher contrast as compared to FBP or OSEM, but OSEM-PVC avoids the increased regional variability of OSEM-RR due to improved structural definition.

  15. Excess molar volumes and partial molar volumes for (propionitrile + an alkanol) at T = 298.15 K and p = 0.1 MPa

    International Nuclear Information System (INIS)

    Deenadayalu, N.; Bhujrajh, P.

    2006-01-01

    The excess molar volumes and the partial molar volumes for (propionitrile + an alkanol) at T = 298.15 K and at atmospheric pressure are reported. The hydrogen bonding between the OH133;NC groups are discussed in terms of the chain length of the alkanol. The alkanols studied are (methanol, ethanol, 1-propanol, 2-propanol, 1-butanol, and 1-pentanol). The excess molar volume data was fitted to the Redlich-Kister equation The partial molar volumes were calculated from the Redlich-Kister coefficients

  16. Thermodynamic study of (heptane + amine) mixtures. II. Excess and partial molar volumes at 298.15 K

    International Nuclear Information System (INIS)

    Lepori, Luciano; Gianni, Paolo; Spanedda, Andrea; Matteoli, Enrico

    2011-01-01

    Research highlights: → Excess and partial molar volumes of primary (amines + heptane) mixtures. → Excess volumes are positive for small size amines and decrease as the size increases. → Group contributions to predict the partial molar volumes of amines in heptane. → The void volume is larger for branched than for linear amines in heptane. - Abstract: Excess molar volumes V E at 298.15 K were determined by means of a vibrating tube densimeter for binary mixtures of heptane + primary n-alkyl (C 3 to C 10 ) and branched amines (iso-propyl-, iso-, sec-, and tert-butyl-, iso-, tert-pentyl-, and pentan-3-amine) in the whole composition range. The apparent molar volumes of solid dodecyl- and tetradecylamine in heptane dilute solution were also determined. The V E values were found positive for mixtures involving C 3 to C 8 linear amines, with V E decreasing with chain lengthening. Heptane + nonyl and decylamine showed s-shaped, markedly asymmetric, curves. Mixtures with branched C 3 to C 5 amines displayed positive V E 's larger than those observed in the mixtures of the corresponding linear isomers. Partial molar volumes V o at infinite dilution in heptane were evaluated for the examined amines and compared with those of alkanes and alkanols taken from the literature. An additivity scheme, based on the intrinsic volume approach, was applied to estimate group (CH 3 , CH 2 , CH, C, NH 2 , and OH) contributions to V o . The effect of branching on V o and the limiting slope of the apparent excess molar volumes were evaluated and discussed in terms of solute-solvent and solute-solute interactions.

  17. Partial volume effect (PVE) on the arterial input function (AIF) in T1-weighted perfusion imaging and limitations of the multiplicative rescaling approach

    DEFF Research Database (Denmark)

    Hansen, Adam Espe; Pedersen, Henrik; Rostrup, Egill

    2009-01-01

    The partial volume effect (PVE) on the arterial input function (AIF) remains a major obstacle to absolute quantification of cerebral blood flow (CBF) using MRI. This study evaluates the validity and performance of a commonly used multiplicative rescaling of the AIF to correct for the PVE. In a gr...

  18. Adaptive partial volume classification of MRI data

    International Nuclear Information System (INIS)

    Chiverton, John P; Wells, Kevin

    2008-01-01

    Tomographic biomedical images are commonly affected by an imaging artefact known as the partial volume (PV) effect. The PV effect produces voxels composed of a mixture of tissues in anatomical magnetic resonance imaging (MRI) data resulting in a continuity of these tissue classes. Anatomical MRI data typically consist of a number of contiguous regions of tissues or even contiguous regions of PV voxels. Furthermore discontinuities exist between the boundaries of these contiguous image regions. The work presented here probabilistically models the PV effect using spatial regularization in the form of continuous Markov random fields (MRFs) to classify anatomical MRI brain data, simulated and real. A unique approach is used to adaptively control the amount of spatial regularization imposed by the MRF. Spatially derived image gradient magnitude is used to identify the discontinuities between image regions of contiguous tissue voxels and PV voxels, imposing variable amounts of regularization determined by simulation. Markov chain Monte Carlo (MCMC) is used to simulate the posterior distribution of the probabilistic image model. Promising quantitative results are presented for PV classification of simulated and real MRI data of the human brain.

  19. Theoretical study of the partial molar volume change associated with the pressure-induced structural transition of ubiquitin.

    Science.gov (United States)

    Imai, Takashi; Ohyama, Shusaku; Kovalenko, Andriy; Hirata, Fumio

    2007-09-01

    The partial molar volume (PMV) change associated with the pressure-induced structural transition of ubiquitin is analyzed by the three-dimensional reference interaction site model (3D-RISM) theory of molecular solvation. The theory predicts that the PMV decreases upon the structural transition, which is consistent with the experimental observation. The volume decomposition analysis demonstrates that the PMV reduction is primarily caused by the decrease in the volume of structural voids in the protein, which is partially canceled by the volume expansion due to the hydration effects. It is found from further analysis that the PMV reduction is ascribed substantially to the penetration of water molecules into a specific part of the protein. Based on the thermodynamic relation, this result implies that the water penetration causes the pressure-induced structural transition. It supports the water penetration model of pressure denaturation of proteins proposed earlier.

  20. FMDP Reactor Alternative Summary Report: Volume 3 - partially complete LWR alternative

    International Nuclear Information System (INIS)

    Greene, S.R.; Fisher, S.E.; Bevard, B.B.

    1996-09-01

    The Department of Energy Office of Fissile Materials Disposition (DOE/MD) initiated a detailed analysis activity to evaluate each of ten plutonium disposition alternatives that survived an initial screening process. This document, Volume 3 of a four volume report summarizes the results of these analyses for the partially complete LWR (PCLWR) reactor based plutonium disposition alternative

  1. FMDP Reactor Alternative Summary Report: Volume 3 - partially complete LWR alternative

    Energy Technology Data Exchange (ETDEWEB)

    Greene, S.R.; Fisher, S.E.; Bevard, B.B. [and others

    1996-09-01

    The Department of Energy Office of Fissile Materials Disposition (DOE/MD) initiated a detailed analysis activity to evaluate each of ten plutonium disposition alternatives that survived an initial screening process. This document, Volume 3 of a four volume report summarizes the results of these analyses for the partially complete LWR (PCLWR) reactor based plutonium disposition alternative.

  2. Twisted finite-volume corrections to K{sub l3} decays with partially-quenched and rooted-staggered quarks

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, Claude [Department of Physics, Washington University,One Brookings Drive, Saint Louis (United States); Bijnens, Johan [Department of Astronomy and Theoretical Physics, Lund University,Sölvegatan 14A, SE 223-62 Lund (Sweden); Gámiz, Elvira [CAFPE and Departamento de Física Teórica y del Cosmos, Universidad de Granada,Campus de Fuente Nueva, E-18002 Granada (Spain); Relefors, Johan [Department of Astronomy and Theoretical Physics, Lund University,Sölvegatan 14A, SE 223-62 Lund (Sweden)

    2017-03-23

    The determination of |V{sub us}| from kaon semileptonic decays requires the value of the form factor f{sub +}(q{sup 2}=0) which can be calculated precisely on the lattice. We provide the one-loop partially quenched chiral perturbation theory expressions both with and without including the effects of staggered quarks for all form factors at finite volume and with partially twisted boundary conditions for both the vector current and scalar density matrix elements at all q{sup 2}. We point out that at finite volume there are more form factors than just f{sub +} and f{sub −} for the vector current matrix element but that the Ward identity is fully satisfied. The size of the finite-volume corrections at present lattice sizes is small. This will help improve the lattice determination of f{sub +}(q{sup 2}=0) since the finite-volume error is the dominant error source for some calculations. The size of the finite-volume corrections may be estimated on a single lattice ensemble by comparing results for various twist choices.

  3. Effect of temperature on the partial molar volume, isentropic compressibility and viscosity of DL-2-aminobutyric acid in water and in aqueous sodium chloride solutions

    International Nuclear Information System (INIS)

    Romero, Carmen M.; Rodríguez, Diana M.; Ribeiro, Ana C.F.; Esteso, Miguel A.

    2017-01-01

    Highlights: • Apparent volumes, apparent compressibilities, viscosities of DL-2-aminobutyric acid. • Effect of temperature on the values for these properties. • Hydrophobic and hydrophilic interactions and the effect of sodium chloride. - Abstract: Density, sound velocity and viscosity of DL-2-aminobutyric acid in water and in aqueous sodium chloride solutions have been measured at temperatures of (293.15, 298.15, 303.15, 308.15 and 313.15) K. The experimental results were used to determine the apparent molar volume and the apparent molar compressibility as a function of composition at these temperatures. The limiting values of both the partial molar volume and the partial molar adiabatic compressibility at infinite dilution of DL-2-aminobutyric acid in water and in aqueous sodium chloride solutions were determined at each temperature. The experimental viscosity values were adjusted by a least-squares method to a second order equation as proposed by Tsangaris-Martin to obtain the viscosity B coefficient which depends on the size, shape and charge of the solute molecule. The influence of the temperature on the behaviour of the selected properties is discussed in terms of both the solute hydration and the balance between hydrophobic and hydrophilic interactions between the acids and water, and the effect of the sodium chloride concentration.

  4. New finite volume methods for approximating partial differential equations on arbitrary meshes

    International Nuclear Information System (INIS)

    Hermeline, F.

    2008-12-01

    This dissertation presents some new methods of finite volume type for approximating partial differential equations on arbitrary meshes. The main idea lies in solving twice the problem to be dealt with. One addresses the elliptic equations with variable (anisotropic, antisymmetric, discontinuous) coefficients, the parabolic linear or non linear equations (heat equation, radiative diffusion, magnetic diffusion with Hall effect), the wave type equations (Maxwell, acoustics), the elasticity and Stokes'equations. Numerous numerical experiments show the good behaviour of this type of method. (author)

  5. Partial volume effect-corrected FDG PET and grey matter volume loss in patients with mild Alzheimer's disease

    International Nuclear Information System (INIS)

    Samuraki, Miharu; Yanase, Daisuke; Yamada, Masahito; Matsunari, Ichiro; Chen, Wei-Ping; Yajima, Kazuyoshi; Fujikawa, Akihiko; Takeda, Nozomi; Nishimura, Shintaro; Matsuda, Hiroshi

    2007-01-01

    Although 18 F-fluorodeoxyglucose (FDG) PET is an established imaging technique to assess brain glucose utilisation, accurate measurement of tracer concentration is confounded by the presence of partial volume effect (PVE) due to the limited spatial resolution of PET, which is particularly true in atrophic brains such as those encountered in patients with Alzheimer's disease (AD). Our aim was to investigate the effects of PVE correction on FDG PET in conjunction with voxel-based morphometry (VBM) in patients with mild AD. Thirty-nine AD patients and 73 controls underwent FDG PET and MRI. The PVE-corrected grey matter PET images were obtained using an MRI-based three-compartment method. Additionally, the results of PET were compared with grey matter loss detected by VBM. Before PVE correction, reduced FDG uptake was observed in posterior cingulate gyri (PCG) and parieto-temporal lobes (PTL) in AD patients, which persisted after PVE correction. Notably, PVE correction revealed relatively preserved FDG uptake in hippocampal areas, despite the grey matter loss in medial temporal lobe (MTL) revealed by VBM. FDG uptake in PCG and PTL is reduced in AD regardless of whether or not PVE correction is applied, supporting the notion that the reduced FDG uptake in these areas is not the result of atrophy. Furthermore, FDG uptake by grey matter tissue in the MTL, including hippocampal areas, is relatively preserved, suggesting that compensatory mechanisms may play a role in patients with mild AD. (orig.)

  6. Whole object surface area and volume of partial-view 3D models

    International Nuclear Information System (INIS)

    Mulukutla, Gopal K; Proussevitch, Alexander A; Genareau, Kimberly D; Durant, Adam J

    2017-01-01

    Micro-scale 3D models, important components of many studies in science and engineering, are often used to determine morphological characteristics such as shape, surface area and volume. The application of techniques such as stereoscopic scanning electron microscopy on whole objects often results in ‘partial-view’ models with a portion of object not within the field of view thus not captured in the 3D model. The nature and extent of the surface not captured is dependent on the complex interaction of imaging system attributes (e.g. working distance, viewing angle) with object size, shape and morphology. As a result, any simplistic assumptions in estimating whole object surface area or volume can lead to significant errors. In this study, we report on a novel technique to estimate the physical fraction of an object captured in a partial-view 3D model of an otherwise whole object. This allows a more accurate estimate of surface area and volume. Using 3D models, we demonstrate the robustness of this method and the accuracy of surface area and volume estimates relative to true values. (paper)

  7. Noise suppressed partial volume correction for cardiac SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Chung; Liu, Chi, E-mail: chi.liu@yale.edu [Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut 06520 (United States); Liu, Hui [Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut 06520 and Key Laboratory of Particle and Radiation Imaging (Tsinghua University), Ministry of Education, Beijing 100084 (China); Grobshtein, Yariv [GE Healthcare, Haifa 3910101 (Israel); Stacy, Mitchel R. [Department of Internal Medicine, Yale University, New Haven, Connecticut 06520 (United States); Sinusas, Albert J. [Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut 06520 and Department of Internal Medicine, Yale University, New Haven, Connecticut 06520 (United States)

    2016-09-15

    Purpose: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging. Methods: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher’s prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang’s method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived from a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a {sup 99m}Tc-tetrofosmin myocardial perfusion scan and a {sup 99m}Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with {sup 99m}Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang’s method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC. Results: The results showed that the Yang’s method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods

  8. Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

    International Nuclear Information System (INIS)

    Gholipour, Ali; Afacan, Onur; Scherrer, Benoit; Prabhu, Sanjay P.; Warfield, Simon K.; Aganj, Iman; Sahin, Mustafa

    2015-01-01

    Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in

  9. Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Gholipour, Ali, E-mail: ali.gholipour@childrens.harvard.edu; Afacan, Onur; Scherrer, Benoit; Prabhu, Sanjay P.; Warfield, Simon K. [Department of Radiology, Boston Children’s Hospital, Boston, Massachusetts 02115 and Harvard Medical School, Boston, Massachusetts 02115 (United States); Aganj, Iman [Radiology Department, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts 02129 and Harvard Medical School, Boston, Massachusetts 02115 (United States); Sahin, Mustafa [Department of Neurology, Boston Children’s Hospital, Boston, Massachusetts 02115 and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2015-12-15

    Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in

  10. Evaluation of the partial volume effect in the activity quantification in PET/CT images; Avaliacao do efeito de volume parcial na quantificacao de atividade em imagens de PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Krempser, Alexandre R., E-mail: krempser@peb.ufrj.br [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Instituto Alberto Luiz Coimbra. Programa de Engenharia Biomedica; Oliveira, Silvia M. Velasques de [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Almeida, Sergio A. de [Hospital Samaritano, Rio de Janeiro, RJ (Brazil). Centro de Imagens PET/CT

    2012-08-15

    The aim of this work was to evaluate the influence of partial volume effect (PVE) in the quantification of activity in images of a PET-CT scanner and its ability to identify lesions. Recovery coefficients were calculated using a phantom containing 12 cylinders with diameters between 4 and 30 mm and a National Electrical Manufactures Association scattering phantom, both fillable with known concentrations of {sup 18}F. The images were acquired for acquisition time of 3 and 5 minutes, and cylinder to background ratio of n=8:1 and n=4:1. The recovery coefficients were calculated between 0.01 and 0.91 depending on the diameter. Significant variations were not found in function of image acquisition parameters. Errors in the activity quantification above 70% were found for cylinders with diameters smaller than 10 mm. The cylinders with diameters smaller than 8 mm were not identified in the images. The phantoms were adequate for PVE evaluation in the PET/CT images. The PVE had the greatest impact on the cylinders with diameters of 6 and 4 mm. It's necessary to use partial volume correction techniques in the images in order to increase the quantitative accuracy of the studied equipment. (author)

  11. PETPVC: a toolbox for performing partial volume correction techniques in positron emission tomography

    Science.gov (United States)

    Thomas, Benjamin A.; Cuplov, Vesna; Bousse, Alexandre; Mendes, Adriana; Thielemans, Kris; Hutton, Brian F.; Erlandsson, Kjell

    2016-11-01

    Positron emission tomography (PET) images are degraded by a phenomenon known as the partial volume effect (PVE). Approaches have been developed to reduce PVEs, typically through the utilisation of structural information provided by other imaging modalities such as MRI or CT. These methods, known as partial volume correction (PVC) techniques, reduce PVEs by compensating for the effects of the scanner resolution, thereby improving the quantitative accuracy. The PETPVC toolbox described in this paper comprises a suite of methods, both classic and more recent approaches, for the purposes of applying PVC to PET data. Eight core PVC techniques are available. These core methods can be combined to create a total of 22 different PVC techniques. Simulated brain PET data are used to demonstrate the utility of toolbox in idealised conditions, the effects of applying PVC with mismatched point-spread function (PSF) estimates and the potential of novel hybrid PVC methods to improve the quantification of lesions. All anatomy-based PVC techniques achieve complete recovery of the PET signal in cortical grey matter (GM) when performed in idealised conditions. Applying deconvolution-based approaches results in incomplete recovery due to premature termination of the iterative process. PVC techniques are sensitive to PSF mismatch, causing a bias of up to 16.7% in GM recovery when over-estimating the PSF by 3 mm. The recovery of both GM and a simulated lesion was improved by combining two PVC techniques together. The PETPVC toolbox has been written in C++, supports Windows, Mac and Linux operating systems, is open-source and publicly available.

  12. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET

    DEFF Research Database (Denmark)

    IIda, H.; Law, I.; Pakkenberg, B.

    2000-01-01

    Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have...... formulated four mathematical models that describe the dynamic behavior of a freely diffusible tracer (H215O) in a region of interest (ROI) incorporating estimates of regional tissue flow that are independent of PVE. The current study was intended to evaluate the feasibility of these models and to establish...... a methodology to accurately quantify regional cerebral blood flow (CBF) corrected for PVE in cortical gray matter regions. Five monkeys were studied with PET after IV H2(15)O two times (n = 3) or three times (n = 2) in a row. Two ROIs were drawn on structural magnetic resonance imaging (MRI) scans and projected...

  13. Determination of Partial Molar Volumes of EPA and DHA Ethyl Esters in Supercritical Carbon Dioxide

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The use of supercritical-fluid chromatography for determining partial molar volumes of ethyl esters of cis-5,8,11,14,17-eicosapentaenoic acid (EPA) and cis -4,7,10,13,16,19- docosa-hexaenoic acid (DHA) in supercritical carbon dioxide is presented and discussed. Partial molar volumes of EPA and DHA esters are obtained from the variation of the retention properties with the density of mobile phase at 313.15 K, 323.15 K, 333.15 K and in the pressure range from 9 MPa to 21 MPa.

  14. Deptermination of Partial Molar Volumes of EPA and DHA Ethyl Esters in Supercritical Carbon Dioxide

    Institute of Scientific and Technical Information of China (English)

    MeiHUANG; XianDaWANG; 等

    2002-01-01

    The use of supercritical-fluid shromatogrphy for determining partial molar volumes of ethyl esters of cis-5,8,11,14,17-eicosapentaenoic acid (EPA) and cis-4,7,10,13,16,19-docosa-hexaenoic acid(DHA) in supercritical carbon dioxide is presented and discussed. Partial molar volumes of EPA and DHA esters are obtained from the variation of the retention properties with the density of mobile phase at 313.15K,323.15K,333.15K and in the pressure range from 9 MPa to 21 MPa.

  15. Partial molar volumes of some drug and pro-drug substances in 1-octanol at T = 298.15 K

    International Nuclear Information System (INIS)

    Manin, Alex N.; Shmukler, Liudmila E.; Safonova, Liubov P.; Perlovich, German L.

    2010-01-01

    The article deals with measuring the densities of phenol, acetanilide, benzamide, benzoic acid, phenacetin, i-(acetylamino)-benzoic acid, i-hydroxy-benzamide, and i-acetaminophen (where i = 1, 2, 3) in 1-octanol in the wide concentration interval at T = 298.15 K. It also concerns the evaluation of apparent molar volumes and partial molar volumes at infinite dilution, V 2 0 -bar as well as comparative analysis of the free volumes per molecule in the octanolic solutions, V 2 free , and in the crystal lattices, V 2 free (cr), from the nature and position of the substitutes. Also described is the evaluation of the increments of V 2 0 -bar andV 2 free for the unsubstituted molecules and isomers and the methods to obtain partial molar volumes for various functional groups at infinite dilution in 1-octanol at T = 298.15 K. Also considered is the limiting partial molar volume of the solutes in terms of the scaled particle theory.

  16. Evaluation of the reconstruction method and effect of partial volume in brain scintiscanning; Avaliacao do metodo de reconstrucao e efeito do volume parcial em cintilografia cerebral

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Monica Araujo

    2016-10-01

    Alzheimer's disease is a neurodegenerative disorder, on which occurs a progressive and irreversible destruction of neurons. According to the World Health Organization (WHO) 35.6 million people are living with dementia, being recommended that governments prioritize early diagnosis techniques. Laboratory and psychological tests for cognitive assessment are conducted and further complemented by neurological imaging from nuclear medicine exams in order to establish an accurate diagnosis. The image quality evaluation and reconstruction process effects are important tools in clinical routine. In the present work, these quality parameters were studied, and the effects of partial volume (PVE) for lesions of different sizes and geometries that are attributed to the limited resolution of the equipment. In dementia diagnosis, this effect can be confused with intake losses due to cerebral cortex atrophy. The evaluation was conducted by two phantoms of different shapes as suggested by (a) American College of Radiology (ACR) and (b) National Electrical Manufacturers Association (NEMA) for Contrast, Contrast-to-Noise Ratio (CNR) and Recovery Coefficient (RC) calculation versus lesions shape and size. Technetium-99m radionuclide was used in a local brain scintigraphy protocol, for proportions lesion to background of 2:1, 4:1, 6:1, 8:1 and 10:1. Fourteen reconstruction methods were used for each concentration applying different filters and algorithms. Before the analysis of all image properties, the conclusion is that the predominant effect is the partial volume, leading to errors of measurement of more than 80%. Furthermore, it was demonstrate that the most effective method of reconstruction is FBP with Metz filter, providing better contrast and contrast to noise ratio results. In addition, this method shows the best Recovery Coefficients correction for each lesion. The ACR phantom showed the best results assigned to a more precise reconstruction of a cylinder, which does not

  17. Impact of partial-volume correction in oncological PET studies. A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cysouw, Matthijs C.F.; Kramer, Gerbrand M.; Hoekstra, Otto S. [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Schoonmade, Linda J. [VU University Medical Centre, Department of Medical Library, Amsterdam (Netherlands); Boellaard, Ronald [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Vet, Henrica C.W. de [VU University Medical Centre, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands)

    2017-11-15

    Positron-emission tomography can be useful in oncology for diagnosis, (re)staging, determining prognosis, and response assessment. However, partial-volume effects hamper accurate quantification of lesions <2-3 x the PET system's spatial resolution, and the clinical impact of this is not evident. This systematic review provides an up-to-date overview of studies investigating the impact of partial-volume correction (PVC) in oncological PET studies. We searched in PubMed and Embase databases according to the PRISMA statement, including studies from inception till May 9, 2016. Two reviewers independently screened all abstracts and eligible full-text articles and performed quality assessment according to QUADAS-2 and QUIPS criteria. For a set of similar diagnostic studies, we statistically pooled the results using bivariate meta-regression. Thirty-one studies were eligible for inclusion. Overall, study quality was good. For diagnosis and nodal staging, PVC yielded a strong trend of increased sensitivity at expense of specificity. Meta-analysis of six studies investigating diagnosis of pulmonary nodules (679 lesions) showed no significant change in diagnostic accuracy after PVC (p = 0.222). Prognostication was not improved for non-small cell lung cancer and esophageal cancer, whereas it did improve for head and neck cancer. Response assessment was not improved by PVC for (locally advanced) breast cancer or rectal cancer, and it worsened in metastatic colorectal cancer. The accumulated evidence to date does not support routine application of PVC in standard clinical PET practice. Consensus on the preferred PVC methodology in oncological PET should be reached. Partial-volume-corrected data should be used as adjuncts to, but not yet replacement for, uncorrected data. (orig.)

  18. A New Approach for Deep Gray Matter Analysis Using Partial-Volume Estimation.

    Science.gov (United States)

    Bonnier, Guillaume; Kober, Tobias; Schluep, Myriam; Du Pasquier, Renaud; Krueger, Gunnar; Meuli, Reto; Granziera, Cristina; Roche, Alexis

    2016-01-01

    The existence of partial volume effects in brain MR images makes it challenging to understand physio-pathological alterations underlying signal changes due to pathology across groups of healthy subjects and patients. In this study, we implement a new approach to disentangle gray and white matter alterations in the thalamus and the basal ganglia. The proposed method was applied to a cohort of early multiple sclerosis (MS) patients and healthy subjects to evaluate tissue-specific alterations related to diffuse inflammatory or neurodegenerative processes. Forty-three relapsing-remitting MS patients and nineteen healthy controls underwent 3T MRI including: (i) fluid-attenuated inversion recovery, double inversion recovery, magnetization-prepared gradient echo for lesion count, and (ii) T1 relaxometry. We applied a partial volume estimation algorithm to T1 relaxometry maps to gray and white matter local concentrations as well as T1 values characteristic of gray and white matter in the thalamus and the basal ganglia. Statistical tests were performed to compare groups in terms of both global T1 values, tissue characteristic T1 values, and tissue concentrations. Significant increases in global T1 values were observed in the thalamus (p = 0.038) and the putamen (p = 0.026) in RRMS patients compared to HC. In the Thalamus, the T1 increase was associated with a significant increase in gray matter characteristic T1 (p = 0.0016) with no significant effect in white matter. The presented methodology provides additional information to standard MR signal averaging approaches that holds promise to identify the presence and nature of diffuse pathology in neuro-inflammatory and neurodegenerative diseases.

  19. Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on local topology

    International Nuclear Information System (INIS)

    Kirov, A S; Schmidtlein, C R; Piao, J Z

    2008-01-01

    Correcting positron emission tomography (PET) images for the partial volume effect (PVE) due to the limited resolution of PET has been a long-standing challenge. Various approaches including incorporation of the system response function in the reconstruction have been previously tested. We present a post-reconstruction PVE correction based on iterative deconvolution using a 3D maximum likelihood expectation-maximization (MLEM) algorithm. To achieve convergence we used a one step late (OSL) regularization procedure based on the assumption of local monotonic behavior of the PET signal following Alenius et al. This technique was further modified to selectively control variance depending on the local topology of the PET image. No prior 'anatomic' information is needed in this approach. An estimate of the noise properties of the image is used instead. The procedure was tested for symmetric and isotropic deconvolution functions with Gaussian shape and full width at half-maximum (FWHM) ranging from 6.31 mm to infinity. The method was applied to simulated and experimental scans of the NEMA NU 2 image quality phantom with the GE Discovery LS PET/CT scanner. The phantom contained uniform activity spheres with diameters ranging from 1 cm to 3.7 cm within uniform background. The optimal sphere activity to variance ratio was obtained when the deconvolution function was replaced by a step function few voxels wide. In this case, the deconvolution method converged in ∼3-5 iterations for most points on both the simulated and experimental images. For the 1 cm diameter sphere, the contrast recovery improved from 12% to 36% in the simulated and from 21% to 55% in the experimental data. Recovery coefficients between 80% and 120% were obtained for all larger spheres, except for the 13 mm diameter sphere in the simulated scan (68%). No increase in variance was observed except for a few voxels neighboring strong activity gradients and inside the largest spheres. Testing the method for

  20. Dilatometric measurement of the partial molar volume of water sorbed to durum wheat flour.

    Science.gov (United States)

    Hasegawa, Ayako; Ogawa, Takenobu; Adachi, Shuji

    2013-01-01

    Moisture sorption isotherms were measured at 25 °C for untreated, dry-heated and pre-gelatinized durum wheat flour samples. The isotherms could be expressed by the Guggenheim-Anderson-de Boer equation. The amount of water sorbed to the untreated flour was highest for low water activity, with water sorbed to the pre-gelatinized and dry-heated flour samples following. The dry-heated and pregelatinized flour samples exhibited the same dependence of the moisture content on the partial molar volume of water at 25 °C as the untreated flour. The partial molar volume of water was ca. 9 cm(3)/mol at a moisture content of 0.03 kg-H2O/kg-d.m. The volume increased with increasing moisture content, and reached a constant value of ca. 17.5 cm(3)/mol at a moisture content of 0.2 kg-H2O/kg-d.m. or higher.

  1. Partial Molar Volumes of 15-Crown-5 Ether in Mixtures of N,N-Dimethylformamide with Water.

    Science.gov (United States)

    Tyczyńska, Magdalena; Jóźwiak, Małgorzata

    2014-01-01

    The density of 15-crown-5 ether (15C5) solutions in the mixtures of N,N -dimethylformamide (DMF) and water (H 2 O) was measured within the temperature range 293.15-308.15 K using an Anton Paar oscillatory U-tube densimeter. The results were used to calculate the apparent molar volumes ( V Φ ) of 15C5 in the mixtures of DMF + H 2 O over the whole concentration range. Using the apparent molar volumes and Redlich and Mayer equation, the standard partial molar volumes of 15-crown-5 were calculated at infinite dilution ([Formula: see text]). The limiting apparent molar expansibilities ( α ) were also calculated. The data are discussed from the point of view of the effect of concentration changes on interactions in solution.

  2. On a relationship between molecular polarizability and partial molar volume in water.

    Science.gov (United States)

    Ratkova, Ekaterina L; Fedorov, Maxim V

    2011-12-28

    We reveal a universal relationship between molecular polarizability (a single-molecule property) and partial molar volume in water that is an ensemble property characterizing solute-solvent systems. Since both of these quantities are of the key importance to describe solvation behavior of dissolved molecular species in aqueous solutions, the obtained relationship should have a high impact in chemistry, pharmaceutical, and life sciences as well as in environments. We demonstrated that the obtained relationship between the partial molar volume in water and the molecular polarizability has in general a non-homogeneous character. We performed a detailed analysis of this relationship on a set of ~200 organic molecules from various chemical classes and revealed its fine well-organized structure. We found that this structure strongly depends on the chemical nature of the solutes and can be rationalized in terms of specific solute-solvent interactions. Efficiency and universality of the proposed approach was demonstrated on an external test set containing several dozens of polyfunctional and druglike molecules.

  3. Partial molar volumes of some drug and pro-drug substances in 1-octanol at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Manin, Alex N.; Shmukler, Liudmila E.; Safonova, Liubov P. [Institute of Solution Chemistry, Russian Academy of Sciences, 153045 Ivanovo (Russian Federation); Perlovich, German L., E-mail: glp@isc-ras.r [Institute of Solution Chemistry, Russian Academy of Sciences, 153045 Ivanovo (Russian Federation)

    2010-03-15

    The article deals with measuring the densities of phenol, acetanilide, benzamide, benzoic acid, phenacetin, i-(acetylamino)-benzoic acid, i-hydroxy-benzamide, and i-acetaminophen (where i = 1, 2, 3) in 1-octanol in the wide concentration interval at T = 298.15 K. It also concerns the evaluation of apparent molar volumes and partial molar volumes at infinite dilution, V{sub 2}{sup 0}-bar as well as comparative analysis of the free volumes per molecule in the octanolic solutions, V{sub 2}{sup free}, and in the crystal lattices, V{sub 2}{sup free} (cr), from the nature and position of the substitutes. Also described is the evaluation of the increments of V{sub 2}{sup 0}-bar andV{sub 2}{sup free} for the unsubstituted molecules and isomers and the methods to obtain partial molar volumes for various functional groups at infinite dilution in 1-octanol at T = 298.15 K. Also considered is the limiting partial molar volume of the solutes in terms of the scaled particle theory.

  4. A method for partial volume correction of PET-imaged tumor heterogeneity using expectation maximization with a spatially varying point spread function

    International Nuclear Information System (INIS)

    Barbee, David L; Holden, James E; Nickles, Robert J; Jeraj, Robert; Flynn, Ryan T

    2010-01-01

    Tumor heterogeneities observed in positron emission tomography (PET) imaging are frequently compromised by partial volume effects which may affect treatment prognosis, assessment or future implementations such as biologically optimized treatment planning (dose painting). This paper presents a method for partial volume correction of PET-imaged heterogeneous tumors. A point source was scanned on a GE Discovery LS at positions of increasing radii from the scanner's center to obtain the spatially varying point spread function (PSF). PSF images were fit in three dimensions to Gaussian distributions using least squares optimization. Continuous expressions were devised for each Gaussian width as a function of radial distance, allowing for generation of the system PSF at any position in space. A spatially varying partial volume correction (SV-PVC) technique was developed using expectation maximization (EM) and a stopping criterion based on the method's correction matrix generated for each iteration. The SV-PVC was validated using a standard tumor phantom and a tumor heterogeneity phantom and was applied to a heterogeneous patient tumor. SV-PVC results were compared to results obtained from spatially invariant partial volume correction (SINV-PVC), which used directionally uniform three-dimensional kernels. SV-PVC of the standard tumor phantom increased the maximum observed sphere activity by 55 and 40% for 10 and 13 mm diameter spheres, respectively. Tumor heterogeneity phantom results demonstrated that as net changes in the EM correction matrix decreased below 35%, further iterations improved overall quantitative accuracy by less than 1%. SV-PVC of clinically observed tumors frequently exhibited changes of ±30% in regions of heterogeneity. The SV-PVC method implemented spatially varying kernel widths and automatically determined the number of iterations for optimal restoration, parameters which are arbitrarily chosen in SINV-PVC. Comparing SV-PVC to SINV-PVC demonstrated

  5. Morphological image processing operators. Reduction of partial volume effects to improve 3D visualization based on CT data

    International Nuclear Information System (INIS)

    Beier, J.; Bittner, R.C.; Hosten, N.; Troeger, J.; Felix, R.

    1998-01-01

    Aim: The quality of segmentation and three-dimensional reconstruction of anatomical structures in tomographic slices is often impaired by disturbances due to partial volume effects (PVE). The potential for artefact reduction by use of the morphological image processing operators (MO) erosion and dilation is investigated. Results: For all patients under review, the artefacts caused by PVE were significantly reduced by erosion (lung: Mean SBR pre =1.67, SBR post =4.83; brain: SBR pre =1.06, SBR post =1.29) even with only a small number of iterations. Region dilation was applied to integrate further structures (e.g. at tumor borders) into a configurable neighbourhood for segmentation and quantitative analysis. Conclusions: The MO represent an efficient approach for the reduction of PVE artefacts in 3D-CT reconstructions and allow optimised visualization of individual objects. (orig./AJ) [de

  6. Buoyancy Effect of Ionic Vacancy on the Change of the Partial Molar Volume in Ferricyanide-Ferrocyanide Redox Reaction under a Vertical Gravity Field

    Directory of Open Access Journals (Sweden)

    Yoshinobu Oshikiri

    2013-01-01

    Full Text Available With a gravity electrode (GE in a vertical gravity field, the buoyancy effect of ionic vacancy on the change of the partial molar volume in the redox reaction between ferricyanide (FERRI and ferrocyanide (FERRO ions was examined. The buoyancy force of ionic vacancy takes a positive or negative value, depending on whether the rate-determining step is the production or extinction of the vacancy. Though the upward convection over an upward electrode in the FERRO ion oxidation suggests the contribution of the positive buoyancy force arising from the vacancy production, the partial molar volume of the vacancy was not measured. On the other hand, for the downward convection under a downward electrode in the FERRI ion reduction, it was not completely but partly measured by the contribution of the negative buoyancy force from the vacancy extinction. Since the lifetime of the vacancy is decreased by the collision between ionic vacancies during the convection, the former result was ascribed to the shortened lifetime due to the increasing collision efficiency in the enhanced upward convection over an upward electrode, whereas the latter was thought to arise from the elongated lifetime due to the decreasing collision efficiency by the stagnation under the downward electrode.

  7. A study of partial molar volumes of citric acid and tartaric acid

    Indian Academy of Sciences (India)

    Partial molar volumes of citric acid and tartaric acid have been determined in water and binary aqueous mixtures of ethanol (5, 10, 15, 20 and 25% by weight of ethanol) at different temperatures and acid concentrations from the solution density measurements. The data have been evaluated by using Masson equation and ...

  8. Finite volume for three-flavour Partially Quenched Chiral Perturbation Theory through NNLO in the meson sector

    International Nuclear Information System (INIS)

    Bijnens, Johan; Rössler, Thomas

    2015-01-01

    We present a calculation of the finite volume corrections to meson masses and decay constants in three flavour Partially Quenched Chiral Perturbation Theory (PQChPT) through two-loop order in the chiral expansion for the flavour-charged (or off-diagonal) pseudoscalar mesons. The analytical results are obtained for three sea quark flavours with one, two or three different masses. We reproduce the known infinite volume results and the finite volume results in the unquenched case. The calculation has been performed using the supersymmetric formulation of PQChPT as well as with a quark flow technique. Partial analytical results can be found in the appendices. Some examples of cases relevant to lattice QCD are studied numerically. Numerical programs for all results are available as part of the CHIRON package.

  9. Finite volume for three-flavour Partially Quenched Chiral Perturbation Theory through NNLO in the meson sector

    Energy Technology Data Exchange (ETDEWEB)

    Bijnens, Johan; Rössler, Thomas [Department of Astronomy and Theoretical Physics, Lund University,Sölvegatan 14A, SE 223-62 Lund (Sweden)

    2015-11-16

    We present a calculation of the finite volume corrections to meson masses and decay constants in three flavour Partially Quenched Chiral Perturbation Theory (PQChPT) through two-loop order in the chiral expansion for the flavour-charged (or off-diagonal) pseudoscalar mesons. The analytical results are obtained for three sea quark flavours with one, two or three different masses. We reproduce the known infinite volume results and the finite volume results in the unquenched case. The calculation has been performed using the supersymmetric formulation of PQChPT as well as with a quark flow technique. Partial analytical results can be found in the appendices. Some examples of cases relevant to lattice QCD are studied numerically. Numerical programs for all results are available as part of the CHIRON package.

  10. A multiresolution image based approach for correction of partial volume effects in emission tomography

    International Nuclear Information System (INIS)

    Boussion, N; Hatt, M; Lamare, F; Bizais, Y; Turzo, A; Rest, C Cheze-Le; Visvikis, D

    2006-01-01

    Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography. They lead to a loss of signal in tissues of size similar to the point spread function and induce activity spillover between regions. Although PVE can be corrected for by using algorithms that provide the correct radioactivity concentration in a series of regions of interest (ROIs), so far little attention has been given to the possibility of creating improved images as a result of PVE correction. Potential advantages of PVE-corrected images include the ability to accurately delineate functional volumes as well as improving tumour-to-background ratio, resulting in an associated improvement in the analysis of response to therapy studies and diagnostic examinations, respectively. The objective of our study was therefore to develop a methodology for PVE correction not only to enable the accurate recuperation of activity concentrations, but also to generate PVE-corrected images. In the multiresolution analysis that we define here, details of a high-resolution image H (MRI or CT) are extracted, transformed and integrated in a low-resolution image L (PET or SPECT). A discrete wavelet transform of both H and L images is performed by using the 'a trous' algorithm, which allows the spatial frequencies (details, edges, textures) to be obtained easily at a level of resolution common to H and L. A model is then inferred to build the lacking details of L from the high-frequency details in H. The process was successfully tested on synthetic and simulated data, proving the ability to obtain accurately corrected images. Quantitative PVE correction was found to be comparable with a method considered as a reference but limited to ROI analyses. Visual improvement and quantitative correction were also obtained in two examples of clinical images, the first using a combined PET/CT scanner with a lymphoma patient and the second using a FDG brain PET and corresponding T1-weighted MRI in

  11. An improved approach to reduce partial volume errors in brain SPET

    International Nuclear Information System (INIS)

    Hatton, R.L.; Hatton, B.F.; Michael, G.; Barnden, L.; QUT, Brisbane, QLD; The Queen Elizabeth Hospital, Adelaide, SA

    1999-01-01

    Full text: Limitations in SPET resolution give rise to significant partial volume error (PVE) in small brain structures We have investigated a previously published method (Muller-Gartner et al., J Cereb Blood Flow Metab 1992;16: 650-658) to correct PVE in grey matter using MRI. An MRI is registered and segmented to obtain a grey matter tissue volume which is then smoothed to obtain resolution matched to the corresponding SPET. By dividing the original SPET with this correction map, structures can be corrected for PVE on a pixel-by-pixel basis. Since this approach is limited by space-invariant filtering, modification was made by estimating projections for the segmented MRI and reconstructing these using identical parameters to SPET. The methods were tested on simulated brain scans, reconstructed with the ordered subsets EM algorithm (8,16, 32, 64 equivalent EM iterations) The new method provided better recovery visually. For 32 EM iterations, recovery coefficients were calculated for grey matter regions. The effects of potential errors in the method were examined. Mean recovery was unchanged with one pixel registration error, the maximum error found in most registration programs. Errors in segmentation > 2 pixels results in loss of accuracy for small structures. The method promises to be useful for reducing PVE in brain SPET

  12. Effective constants for wave propagation through partially saturated porous media

    International Nuclear Information System (INIS)

    Berryman, J.G.; Thigpen, L.

    1985-01-01

    The multipole scattering coefficients for elastic wave scattering from a spherical inhomogeneity in a fluid-saturated porous medium have been calculated. These coefficients may be used to obtain estimates of the effective macroscopic constants for long-wavelength propagation of elastic waves through partially saturated media. If the volume average of the single scattering from spherical bubbles of gas and liquid is required to vanish, the resulting equations determine the effective bulk modulus, density, and viscosity of the multiphase fluid filling the pores. The formula for the effective viscosity during compressional wave excitation is apparently new

  13. Calculation of partial molar volume of components in supercritical ammonia synthesis system

    Institute of Scientific and Technical Information of China (English)

    Cunwen WANG; Chuanbo YU; Wen CHEN; Weiguo WANG; Yuanxin WU; Junfeng ZHANG

    2008-01-01

    The partial molar volumes of components in supercritical ammonia synthesis system are calculated in detail by the calculation formula of partial molar volume derived from the R-K equation of state under different conditions. The objectives are to comprehend phase beha-vior of components and to provide the theoretic explana-tion and guidance for probing novel processes of ammonia synthesis under supercritical conditions. The conditions of calculation are H2/N2= 3, at a concentra-tion of NH3 in synthesis gas ranging from 2% to 15%, Concentration of medium in supercritical ammonia syn-thesis system ranging from 20% to 50%, temperature ran-ging from 243 K to 699 K and pressure ranging from 0.1 MPa to 187 MPa. The results show that the ammonia synthesis system can reach supercritical state by adding a suitable supercritical medium and then controlling the reaction conditions. It is helpful for the supercritical ammonia synthesis that medium reaches supercritical state under the conditions of the corresponding total pres-sure and components near the normal temperature or near the critical temperature of medium or in the range of tem-perature of industrialized ammonia synthesis.

  14. Hydrophobic hydration and the anomalous partial molar volumes in ethanol-water mixtures

    International Nuclear Information System (INIS)

    Tan, Ming-Liang; Te, Jerez; Cendagorta, Joseph R.; Miller, Benjamin T.; Brooks, Bernard R.; Ichiye, Toshiko

    2015-01-01

    The anomalous behavior in the partial molar volumes of ethanol-water mixtures at low concentrations of ethanol is studied using molecular dynamics simulations. Previous work indicates that the striking minimum in the partial molar volume of ethanol V E as a function of ethanol mole fraction X E is determined mainly by water-water interactions. These results were based on simulations that used one water model for the solute-water interactions but two different water models for the water-water interactions. This is confirmed here by using two more water models for the water-water interactions. Furthermore, the previous work indicates that the initial decrease is caused by association of the hydration shells of the hydrocarbon tails, and the minimum occurs at the concentration where all of the hydration shells are touching each other. Thus, the characteristics of the hydration of the tail that cause the decrease and the features of the water models that reproduce this type of hydration are also examined here. The results show that a single-site multipole water model with a charge distribution that mimics the large quadrupole and the p-orbital type electron density out of the molecular plane has “brittle” hydration with hydrogen bonds that break as the tails touch, which reproduces the deep minimum. However, water models with more typical site representations with partial charges lead to flexible hydration that tends to stay intact, which produces a shallow minimum. Thus, brittle hydration may play an essential role in hydrophobic association in water

  15. Partial molar volume of mefenamic acid in alcohol at temperatures between T=293.15 and T=313.15 K

    OpenAIRE

    Iqbal, Muhammad J.; Siddiquah, Mahrukh

    2006-01-01

    Apparent molar volume (Vphi), partial molar volume (V), solute-solute interaction parameter (Sv), partial molar expansivity (E(0)2) and isobaric thermal expansion coefficient (alpha2) of mefenamic acid in six different organic solvents namely, methanol, ethanol, 1-propanol, 2-propanol, 1-butanol, and 2-butanol, have been calculated from the measured solution densities over a temperature range of T=293.15 and T=313.15±0.1K. The solution densities were measured by an automated vibrating tube de...

  16. Multi-tissue partial volume quantification in multi-contrast MRI using an optimised spectral unmixing approach.

    Science.gov (United States)

    Collewet, Guylaine; Moussaoui, Saïd; Deligny, Cécile; Lucas, Tiphaine; Idier, Jérôme

    2018-06-01

    Multi-tissue partial volume estimation in MRI images is investigated with a viewpoint related to spectral unmixing as used in hyperspectral imaging. The main contribution of this paper is twofold. It firstly proposes a theoretical analysis of the statistical optimality conditions of the proportion estimation problem, which in the context of multi-contrast MRI data acquisition allows to appropriately set the imaging sequence parameters. Secondly, an efficient proportion quantification algorithm based on the minimisation of a penalised least-square criterion incorporating a regularity constraint on the spatial distribution of the proportions is proposed. Furthermore, the resulting developments are discussed using empirical simulations. The practical usefulness of the spectral unmixing approach for partial volume quantification in MRI is illustrated through an application to food analysis on the proving of a Danish pastry. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Partial volume effect estimation and correction in the aortic vascular wall in PET imaging

    International Nuclear Information System (INIS)

    Burg, S; Le Guludec, D; Dupas, A; Stute, S; Dieudonné, A; Huet, P; Buvat, I

    2013-01-01

    We evaluated the impact of partial volume effect (PVE) in the assessment of arterial diseases with 18 FDG PET. An anthropomorphic digital phantom enabling the modeling of aorta related diseases like atherosclerosis and arteritis was used. Based on this phantom, we performed GATE Monte Carlo simulations to produce realistic PET images with a known organ segmentation and ground truth activity values. Images corresponding to 15 different activity-concentration ratios between the aortic wall and the blood and to 7 different wall thicknesses were generated. Using the PET images, we compared the theoretical wall-to-blood activity-concentration ratios (WBRs) with the measured WBRs obtained with five measurement methods: (1) measurement made by a physician (Expert), (2) automated measurement supposed to mimic the physician measurements (Max), (3) simple correction based on a recovery coefficient (Max-RC), (4) measurement based on an ideal VOI segmentation (Mean-VOI) and (5) measurement corrected for PVE using an ideal geometric transfer matrix (GTM) method. We found that Mean-VOI WBRs values were strongly affected by PVE. WBRs obtained by the physician measurement, by the Max method and by the Max-RC method were more accurate than WBRs obtained with the Mean-VOI approach. However Expert, Max and Max-RC WBRs strongly depended on the wall thickness. Only the GTM corrected WBRs did not depend on the wall thickness. Using the GTM method, we obtained more reproducible ratio values that could be compared across wall thickness. Yet, the feasibility of the implementation of a GTM-like method on real data remains to be studied. (paper)

  18. Partial molar volumes of (acetonitrile + water) mixtures over the temperature range (273.15 to 318.15) K

    International Nuclear Information System (INIS)

    Yeow, Y. Leong; Leong, Yee-Kwong

    2007-01-01

    Isothermal molar volume data of (acetonitrile + water) mixtures, between T = 273.15 K and T = 318.15 K, extracted from different sources are combined and treated as a single set to even out minor differences between sources and to increase the number of data points for each temperature. Tikhonov regularization is applied to compute the isothermal first and second derivatives of these data with respect to molar composition. For the reference temperature of 298.15 K, this computation is extended to the third derivative. Generalized Cross Validation is used to guide the selection of the regularization parameter that keeps noise amplification under control. The resulting first derivatives are used to construct the partial molar volume curves which are then checked against published results. Properties of the partial molar volumes are analysed by examining their derivatives. Finally the general shape of the second derivative curve of molar volume is explained qualitatively in terms of tripartite segmentation of the molar composition interval but quantitative comparisons are required to confirm this explanation

  19. Finite volume for three-flavour Partially Quenched Chiral Perturbation Theory through NNLO in the meson sector

    Science.gov (United States)

    Bijnens, Johan; Rössler, Thomas

    2015-11-01

    We present a calculation of the finite volume corrections to meson masses and decay constants in three flavour Partially Quenched Chiral Perturbation Theory (PQChPT) through two-loop order in the chiral expansion for the flavour-charged (or off-diagonal) pseudoscalar mesons. The analytical results are obtained for three sea quark flavours with one, two or three different masses. We reproduce the known infinite volume results and the finite volume results in the unquenched case. The calculation has been performed using the supersymmetric formulation of PQChPT as well as with a quark flow technique.

  20. PET imaging of thin objects: measuring the effects of positron range and partial-volume averaging in the leaf of Nicotiana tabacum

    Energy Technology Data Exchange (ETDEWEB)

    Alexoff, David L., E-mail: alexoff@bnl.gov; Dewey, Stephen L.; Vaska, Paul; Krishnamoorthy, Srilalan; Ferrieri, Richard; Schueller, Michael; Schlyer, David J.; Fowler, Joanna S.

    2011-02-15

    Introduction: PET imaging in plants is receiving increased interest as a new strategy to measure plant responses to environmental stimuli and as a tool for phenotyping genetically engineered plants. PET imaging in plants, however, poses new challenges. In particular, the leaves of most plants are so thin that a large fraction of positrons emitted from PET isotopes ({sup 18}F, {sup 11}C, {sup 13}N) escape while even state-of-the-art PET cameras have significant partial-volume errors for such thin objects. Although these limitations are acknowledged by researchers, little data have been published on them. Methods: Here we measured the magnitude and distribution of escaping positrons from the leaf of Nicotiana tabacum for the radionuclides {sup 18}F, {sup 11}C and {sup 13}N using a commercial small-animal PET scanner. Imaging results were compared to radionuclide concentrations measured from dissection and counting and to a Monte Carlo simulation using GATE (Geant4 Application for Tomographic Emission). Results: Simulated and experimentally determined escape fractions were consistent. The fractions of positrons (mean{+-}S.D.) escaping the leaf parenchyma were measured to be 59{+-}1.1%, 64{+-}4.4% and 67{+-}1.9% for {sup 18}F, {sup 11}C and {sup 13}N, respectively. Escape fractions were lower in thicker leaf areas like the midrib. Partial-volume averaging underestimated activity concentrations in the leaf blade by a factor of 10 to 15. Conclusions: The foregoing effects combine to yield PET images whose contrast does not reflect the actual activity concentrations. These errors can be largely corrected by integrating activity along the PET axis perpendicular to the leaf surface, including detection of escaped positrons, and calculating concentration using a measured leaf thickness.

  1. Combining MRI with PET for partial volume correction improves image-derived input functions in mice

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Eleanor; Buonincontri, Guido [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Izquierdo, David [Athinoula A Martinos Centre, Harvard University, Cambridge, MA (United States); Methner, Carmen [Department of Medicine, University of Cambridge, Cambridge (United Kingdom); Hawkes, Rob C [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Ansorge, Richard E [Department of Physics, University of Cambridge, Cambridge (United Kingdom); Kreig, Thomas [Department of Medicine, University of Cambridge, Cambridge (United Kingdom); Carpenter, T Adrian [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Sawiak, Stephen J [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Behavioural and Clinical Neurosciences Institute, University of Cambridge, Cambridge (United Kingdom)

    2014-07-29

    Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. This measure is challenging to obtain in mice due to low blood volumes, resulting in a reliance on image-based methods for AIF derivation. We present a comparison of PET- and MR-based region-of-interest (ROI) analysis to obtain image-derived AIFs from the left ventricle (LV) of a mouse model. ROI-based partial volume correction (PVC) was performed to improve quantification.

  2. Combining MRI with PET for partial volume correction improves image-derived input functions in mice

    International Nuclear Information System (INIS)

    Evans, Eleanor; Buonincontri, Guido; Izquierdo, David; Methner, Carmen; Hawkes, Rob C; Ansorge, Richard E; Kreig, Thomas; Carpenter, T Adrian; Sawiak, Stephen J

    2014-01-01

    Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. This measure is challenging to obtain in mice due to low blood volumes, resulting in a reliance on image-based methods for AIF derivation. We present a comparison of PET- and MR-based region-of-interest (ROI) analysis to obtain image-derived AIFs from the left ventricle (LV) of a mouse model. ROI-based partial volume correction (PVC) was performed to improve quantification.

  3. The (water + acetonitrile) mixture revisited: A new approach for calculating partial molar volumes

    International Nuclear Information System (INIS)

    Carmen Grande, Maria del; Julia, Jorge Alvarez; Barrero, Carmen R.; Marschoff, Carlos M.; Bianchi, Hugo L.

    2006-01-01

    Density and viscosity of (water + acetonitrile) mixtures were measured over the whole composition range at the temperatures: (298.15, 303.15, 308.15, 313.15, and 318.15) K. A new mathematical approach was developed which allows the calculation of the derivatives of density with respect to composition avoiding the appearance of local discontinuities. Thus, reliable partial molar volumes and thermal expansion coefficients were obtained

  4. Target volume delineation in external beam partial breast irradiation: less inter-observer variation with preoperative- compared to postoperative delineation

    NARCIS (Netherlands)

    Leij, F. van der; Elkhuizen, P.H.M.; Janssen, T.M.; Poortmans, P.M.P.; Sangen, M. van der; Scholten, A.N.; Vliet-Vroegindeweij, C. van; Boersma, L.J.

    2014-01-01

    The challenge of adequate target volume definition in external beam partial breast irradiation (PBI) could be overcome with preoperative irradiation, due to less inter-observer variation. We compared the target volume delineation for external beam PBI on preoperative versus postoperative CT scans of

  5. Brain extraction in partial volumes T2*@7T by using a quasi-anatomic segmentation with bias field correction.

    Science.gov (United States)

    Valente, João; Vieira, Pedro M; Couto, Carlos; Lima, Carlos S

    2018-02-01

    Poor brain extraction in Magnetic Resonance Imaging (MRI) has negative consequences in several types of brain post-extraction such as tissue segmentation and related statistical measures or pattern recognition algorithms. Current state of the art algorithms for brain extraction work on weighted T1 and T2, being not adequate for non-whole brain images such as the case of T2*FLASH@7T partial volumes. This paper proposes two new methods that work directly in T2*FLASH@7T partial volumes. The first is an improvement of the semi-automatic threshold-with-morphology approach adapted to incomplete volumes. The second method uses an improved version of a current implementation of the fuzzy c-means algorithm with bias correction for brain segmentation. Under high inhomogeneity conditions the performance of the first method degrades, requiring user intervention which is unacceptable. The second method performed well for all volumes, being entirely automatic. State of the art algorithms for brain extraction are mainly semi-automatic, requiring a correct initialization by the user and knowledge of the software. These methods can't deal with partial volumes and/or need information from atlas which is not available in T2*FLASH@7T. Also, combined volumes suffer from manipulations such as re-sampling which deteriorates significantly voxel intensity structures making segmentation tasks difficult. The proposed method can overcome all these difficulties, reaching good results for brain extraction using only T2*FLASH@7T volumes. The development of this work will lead to an improvement of automatic brain lesions segmentation in T2*FLASH@7T volumes, becoming more important when lesions such as cortical Multiple-Sclerosis need to be detected. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Quantification accuracy and partial volume effect in dependence of the attenuation correction of a state-of-the-art small animal PET scanner

    International Nuclear Information System (INIS)

    Mannheim, Julia G; Judenhofer, Martin S; Schmid, Andreas; Pichler, Bernd J; Tillmanns, Julia; Stiller, Detlef; Sossi, Vesna

    2012-01-01

    Quantification accuracy and partial volume effect (PVE) of the Siemens Inveon PET scanner were evaluated. The influence of transmission source activities (40 and 160 MBq) on the quantification accuracy and the PVE were determined. Dynamic range, object size and PVE for different sphere sizes, contrast ratios and positions in the field of view (FOV) were evaluated. The acquired data were reconstructed using different algorithms and correction methods. The activity level of the transmission source and the total emission activity in the FOV strongly influenced the attenuation maps. Reconstruction algorithms, correction methods, object size and location within the FOV had a strong influence on the PVE in all configurations. All evaluated parameters potentially influence the quantification accuracy. Hence, all protocols should be kept constant during a study to allow a comparison between different scans. (paper)

  7. Partial twisting for scalar mesons

    International Nuclear Information System (INIS)

    Agadjanov, Dimitri; Meißner, Ulf-G.; Rusetsky, Akaki

    2014-01-01

    The possibility of imposing partially twisted boundary conditions is investigated for the scalar sector of lattice QCD. According to the commonly shared belief, the presence of quark-antiquark annihilation diagrams in the intermediate state generally hinders the use of the partial twisting. Using effective field theory techniques in a finite volume, and studying the scalar sector of QCD with total isospin I=1, we however demonstrate that partial twisting can still be performed, despite the fact that annihilation diagrams are present. The reason for this are delicate cancellations, which emerge due to the graded symmetry in partially quenched QCD with valence, sea and ghost quarks. The modified Lüscher equation in case of partial twisting is given

  8. Target volume delineation in external beam partial breast irradiation: Less inter-observer variation with preoperative- compared to postoperative delineation

    International Nuclear Information System (INIS)

    Leij, Femke van der; Elkhuizen, Paula H.M.; Janssen, Tomas M.; Poortmans, Philip; Sangen, Maurice van der; Scholten, Astrid N.; Vliet-Vroegindeweij, Corine van; Boersma, Liesbeth J.

    2014-01-01

    The challenge of adequate target volume definition in external beam partial breast irradiation (PBI) could be overcome with preoperative irradiation, due to less inter-observer variation. We compared the target volume delineation for external beam PBI on preoperative versus postoperative CT scans of twenty-four breast cancer patients

  9. Intrinsic alterations in the partial molar volume on the protein denaturation: surficial Kirkwood-Buff approach.

    Science.gov (United States)

    Yu, Isseki; Takayanagi, Masayoshi; Nagaoka, Masataka

    2009-03-19

    The partial molar volume (PMV) of the protein chymotrypsin inhibitor 2 (CI2) was calculated by all-atom MD simulation. Denatured CI2 showed almost the same average PMV value as that of native CI2. This is consistent with the phenomenological question of the protein volume paradox. Furthermore, using the surficial Kirkwood-Buff approach, spatial distributions of PMV were analyzed as a function of the distance from the CI2 surface. The profiles of the new R-dependent PMV indicate that, in denatured CI2, the reduction in the solvent electrostatic interaction volume is canceled out mainly by an increment in thermal volume in the vicinity of its surface. In addition, the PMV of the denatured CI2 was found to increase in the region in which the number density of water atoms is minimum. These results provide a direct and detailed picture of the mechanism of the protein volume paradox suggested by Chalikian et al.

  10. Partial molar volume and isentropic compressibility of symmetrical and asymmetrical quaternary ammonium bromides in aqueous solution

    International Nuclear Information System (INIS)

    Moreno, Nicolás; Buchner, Richard; Vargas, Edgar F.

    2015-01-01

    Highlights: • Structural effects of the cations on surrounding water molecules are discussed. • Alkyl-chain geometry determines the hydration of Bu 4 N + isomers. • The “compactness” in the hydration shells varies significantly among the isomers. - Abstract: Values of apparent molar volume and isentropic compressibility of symmetric and asymmetric isomers of tetrabutylammonium bromide, namely tetra-n-butylammonium bromide, tetra-iso-butylammonium bromide, tetra-sec-butylammonium bromide, di-n-butyl-di-iso-butylammonium bromide and di-n-butyl-di-sec-butylammonium bromide, in aqueous solution were determined from density and speed of sound measurements. These properties were obtained as a function of molal concentration within the range of 0.01 < m/mol · kg −1 < 0.1 covering temperatures from 278.15 ⩽ T/K ⩽ 293.15. The partial molar volumes and the apparent isentropic molar compressibility at infinite dilution were calculated and their dependence on temperature examined. The results show that cations with sec-butyl chains have larger structural volumes compared to those with iso-butyl chains. In addition, cations with sec-butyl chains induce smaller structural changes in their hydration shell than the others

  11. Different partial volume correction methods lead to different conclusions: An (18)F-FDG-PET study of aging.

    Science.gov (United States)

    Greve, Douglas N; Salat, David H; Bowen, Spencer L; Izquierdo-Garcia, David; Schultz, Aaron P; Catana, Ciprian; Becker, J Alex; Svarer, Claus; Knudsen, Gitte M; Sperling, Reisa A; Johnson, Keith A

    2016-05-15

    A cross-sectional group study of the effects of aging on brain metabolism as measured with (18)F-FDG-PET was performed using several different partial volume correction (PVC) methods: no correction (NoPVC), Meltzer (MZ), Müller-Gärtner (MG), and the symmetric geometric transfer matrix (SGTM) using 99 subjects aged 65-87years from the Harvard Aging Brain study. Sensitivity to parameter selection was tested for MZ and MG. The various methods and parameter settings resulted in an extremely wide range of conclusions as to the effects of age on metabolism, from almost no changes to virtually all of cortical regions showing a decrease with age. Simulations showed that NoPVC had significant bias that made the age effect on metabolism appear to be much larger and more significant than it is. MZ was found to be the same as NoPVC for liberal brain masks; for conservative brain masks, MZ showed few areas correlated with age. MG and SGTM were found to be similar; however, MG was sensitive to a thresholding parameter that can result in data loss. CSF uptake was surprisingly high at about 15% of that in gray matter. The exclusion of CSF from SGTM and MG models, which is almost universally done, caused a substantial loss in the power to detect age-related changes. This diversity of results reflects the literature on the metabolism of aging and suggests that extreme care should be taken when applying PVC or interpreting results that have been corrected for partial volume effects. Using the SGTM, significant age-related changes of about 7% per decade were found in frontal and cingulate cortices as well as primary visual and insular cortices. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Different Partial Volume Correction Methods Lead to Different Conclusions: an 18F-FDG PET Study of Aging

    Science.gov (United States)

    Greve, Douglas N.; Salat, David H.; Bowen, Spencer L.; Izquierdo-Garcia, David; Schultz, Aaron P.; Catana, Ciprian; Becker, J. Alex; Svarer, Claus; Knudsen, Gitte; Sperling, Reisa A.; Johnson, Keith A.

    2016-01-01

    A cross-sectional group study of the effects of aging on brain metabolism as measured with 18F-FDG PET was performed using several different partial volume correction (PVC) methods: no correction (NoPVC), Meltzer (MZ), Müller-Gärtner (MG), and the symmetric geometric transfer matrix (SGTM) using 99 subjects aged 65-87 from the Harvard Aging Brain study. Sensitivity to parameter selection was tested for MZ and MG. The various methods and parameter settings resulted in an extremely wide range of conclusions as to the effects of age on metabolism, from almost no changes to virtually all of cortical regions showing a decrease with age. Simulations showed that NoPVC had significant bias that made the age effect on metabolism appear to be much larger and more significant than it is. MZ was found to be the same as NoPVC for liberal brain masks; for conservative brain masks, MZ showed few areas correlated with age. MG and SGTM were found to be similar; however, MG was sensitive to a thresholding parameter that can result in data loss. CSF uptake was surprisingly high at about 15% of that in gray matter. Exclusion of CSF from SGTM and MG models, which is almost universally done, caused a substantial loss in the power to detect age-related changes. This diversity of results reflects the literature on the metabolism of aging and suggests that extreme care should be taken when applying PVC or interpreting results that have been corrected for partial volume effects. Using the SGTM, significant age-related changes of about 7% per decade were found in frontal and cingulate cortices as well as primary visual and insular cortices. PMID:26915497

  13. The electric strength of high-voltage transformers insulation at effect of partial dischargers

    International Nuclear Information System (INIS)

    Khoshravan, E.; Zeraatparvar, A.; Gashimov, A.M.; Mehdizadeh, R.N.

    2001-01-01

    Full text : In paper the change of electric strength of high-voltage transformers insulation at the effect of partial discharges with space charge accumulation was investigated. It is revealed that the effect of partial discharges of insulation materials results the reduction of their pulsing electric strength which can restore the own initial value at releasing of saved charge the volume of a material under condition of absence the ineversible structural changes in it. Researches of high-voltage transformers insulation's non-failure operation conditions show, that at increasing of insulation work time in a strong electrical field the reduction of average breakdown voltages with simultaneous increasing of spread in discharge voltage values takes place. It authentically testifies to reduction of short-time discharge voltage of insulation materials during their electrical aging. As the basic reason of insulation electrical aging the partial discharges occurring in gas cavities inside insulation were considered. It is known that the space charges will be formed in insulation elements of high-voltage devices which effects in dielectrical property of these elements including the electric strength and the space charge formation can occur also at partial discharges in an alternating voltage while the service of high-voltage transformers. In the given work the experiments in revealing separate influence partial discharges in pulsing electric strength of insulation materials at presence and at absence inside them the space charge were spent

  14. Hydration of alcohol clusters in 1-propanol-water mixture studied by quasielastic neutron scattering and an interpretation of anomalous excess partial molar volume.

    Science.gov (United States)

    Misawa, M; Inamura, Y; Hosaka, D; Yamamuro, O

    2006-08-21

    Quasielastic neutron scattering measurements have been made for 1-propanol-water mixtures in a range of alcohol concentration from 0.0 to 0.167 in mole fraction at 25 degrees C. Fraction alpha of water molecules hydrated to fractal surface of alcohol clusters in 1-propanol-water mixture was obtained as a function of alcohol concentration. Average hydration number N(ws) of 1-propanol molecule is derived from the value of alpha as a function of alcohol concentration. By extrapolating N(ws) to infinite dilution, we obtain values of 12-13 as hydration number of isolated 1-propanol molecule. A simple interpretation of structural origin of anomalous excess partial molar volume of water is proposed and as a result a simple equation for the excess partial molar volume is deduced in terms of alpha. Calculated values of the excess partial molar volumes of water and 1-propanol and the excess molar volume of the mixture are in good agreement with experimental values.

  15. Partial molar volumes of L-alanine, DL-serine, DL-threonine, L-histidine, glycine, and glycylglycine in water, NaCl, and DMSO aqueous solutions at T 298.15 K

    International Nuclear Information System (INIS)

    Yuan Quan; Li Zhifen; Wang Baohuai

    2006-01-01

    The apparent molar volumes of L-alanine, DL-serine, DL-threonine, L-histidine, glycine, and glycylglycine in water and in the aqueous solutions of NaCl and DMSO with various concentrations at T = 298.15 K have been measured by the precise vibrating-tube digital densimeter. The calculated partial molar volumes at infinite dilution have been used to obtain corresponding transfer volumes from water to various solutions. The experimental results show that the standard partial molar volumes of the above amino acids and peptide at the dilute DMSO aqueous solutions are very close to those in water. However, the volumes show several types of variations with the increase of the concentrations of DMSO due to different types of side chain of amino acids, which should be discussed specifically. The NaCl changes considerably the infinite dilution standard partial molar volumes of the above amino acids and peptide in the aqueous solutions. The infinite dilution standard partial molar volumes of the each amino acids and peptide increase with the concentrations of NaCl. The experimental results have been rationalized by a cosphere overlap model

  16. Fast Computation of Solvation Free Energies with Molecular Density Functional Theory: Thermodynamic-Ensemble Partial Molar Volume Corrections.

    Science.gov (United States)

    Sergiievskyi, Volodymyr P; Jeanmairet, Guillaume; Levesque, Maximilien; Borgis, Daniel

    2014-06-05

    Molecular density functional theory (MDFT) offers an efficient implicit-solvent method to estimate molecule solvation free-energies, whereas conserving a fully molecular representation of the solvent. Even within a second-order approximation for the free-energy functional, the so-called homogeneous reference fluid approximation, we show that the hydration free-energies computed for a data set of 500 organic compounds are of similar quality as those obtained from molecular dynamics free-energy perturbation simulations, with a computer cost reduced by 2-3 orders of magnitude. This requires to introduce the proper partial volume correction to transform the results from the grand canonical to the isobaric-isotherm ensemble that is pertinent to experiments. We show that this correction can be extended to 3D-RISM calculations, giving a sound theoretical justification to empirical partial molar volume corrections that have been proposed recently.

  17. Thermodynamic study of (heptane + amine) mixtures. III: Excess and partial molar volumes in mixtures with secondary, tertiary, and cyclic amines at 298.15 K

    International Nuclear Information System (INIS)

    Lepori, Luciano; Gianni, Paolo; Spanedda, Andrea; Matteoli, Enrico

    2011-01-01

    Graphical abstract: Highlights: → Excess volumes of (sec., tert., or cyclic amines + heptane) mixtures. → Excess volumes are positive for small size amines and decrease as the size increases. → Group contributions to predict the partial molar volumes of amines in heptane. → The void volume is larger for sec. and tert. than for linear amines in heptane. → The void volume is much smaller for cyclic than for linear amines in heptane. - Abstract: Excess molar volumes V E at 298.15 K were determined by means of a vibrating tube densimeter for binary mixtures of {heptane + open chain secondary (diethyl to dibutyl) and tertiary (triethyl to tripentyl) amines} as well as for cyclic imines (C 2 , C 3 , C 4 , C 6 , and C 7 ) and primary cycloalkylamines (C 5 , C 6 , C 7 , and C 12 ). The V E values were found positive for mixtures involving small size amines, with V E decreasing as the size increases. Negative V E 's were found for tributyl- and tripentylamine, heptamethylenimine, and cyclododecylamine. Mixtures of heptane with cycloheptylamine showed an s-shaped curve. Partial molar volumes V 0 of amines at infinite dilution in heptane were obtained from V E and compared with V 0 of hydrocarbons and other classes of organic compounds taken from literature. An additivity scheme, based on the intrinsic volume approach, was applied to estimate group (CH 3 , CH 2 , CH, C, NH 2 , NH, N, OH, O, CO, and COO) contributions to V 0 . These contributions, the effect of cyclization on V 0 , and the limiting slope of the apparent excess molar volumes were discussed in terms of solute-solvent and solute-solute interactions.

  18. The Effect of Dose-Volume Parameters and Interfraction Interval on Cosmetic Outcome and Toxicity After 3-Dimensional Conformal Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Leonard, Kara Lynne; Hepel, Jaroslaw T.; Hiatt, Jessica R.; Dipetrillo, Thomas A.; Price, Lori Lyn; Wazer, David E.

    2013-01-01

    Purpose: To evaluate dose-volume parameters and the interfraction interval (IFI) as they relate to cosmetic outcome and normal tissue effects of 3-dimensional conformal radiation therapy (3D-CRT) for accelerated partial breast irradiation (APBI). Methods and Materials: Eighty patients were treated by the use of 3D-CRT to deliver APBI at our institutions from 2003-2010 in strict accordance with the specified dose-volume constraints outlined in the National Surgical Adjuvant Breast and Bowel Project B39/Radiation Therapy Oncology Group 0413 (NSABP-B39/RTOG 0413) protocol. The prescribed dose was 38.5 Gy in 10 fractions delivered twice daily. Patients underwent follow-up with assessment for recurrence, late toxicity, and overall cosmetic outcome. Tests for association between toxicity endpoints and dosimetric parameters were performed with the chi-square test. Univariate logistic regression was used to evaluate the association of interfraction interval (IFI) with these outcomes. Results: At a median follow-up time of 32 months, grade 2-4 and grade 3-4 subcutaneous fibrosis occurred in 31% and 7.5% of patients, respectively. Subcutaneous fibrosis improved in 5 patients (6%) with extended follow-up. Fat necrosis developed in 11% of women, and cosmetic outcome was fair/poor in 19%. The relative volume of breast tissue receiving 5%, 20%, 50%, 80%, and 100% (V5-V100) of the prescribed dose was associated with risk of subcutaneous fibrosis, and the volume receiving 50%, 80%, and 100% (V50-V100) was associated with fair/poor cosmesis. The mean IFI was 6.9 hours, and the minimum IFI was 6.2 hours. The mean and minimum IFI values were not significantly associated with late toxicity. Conclusions: The incidence of moderate to severe late toxicity, particularly subcutaneous fibrosis and fat necrosis and resulting fair/poor cosmesis, remains high with continued follow-up. These toxicity endpoints are associated with several dose-volume parameters. Minimum and mean IFI values were

  19. Chiral and continuum extrapolation of partially quenched lattice results

    Energy Technology Data Exchange (ETDEWEB)

    C.R. Allton; W. Armour; D.B. Leinweber; A.W. Thomas; R.D. Young

    2005-04-01

    The vector meson mass is extracted from a large sample of partially quenched, two-flavor lattice QCD simulations. For the first time, discretization, finite-volume and partial quenching artifacts are treated in a unified chiral effective field theory analysis of the lattice simulation results.

  20. A spreadsheet to determine the volume ratio for target and breast in partial breast irradiation

    International Nuclear Information System (INIS)

    Kron, T.; Willis, D.; Miller, J.; Hubbard, P.; Oliver, M.; Chua, B.

    2009-01-01

    Full text: The technical feasibility of Partial Breast Irradiation (PBI) using external beam radiotherapy depends on the ratio between the evaluation planning target volume (PTV e val) and the whole breast volume (PBI volume ratio = PVR). We aimed to develop a simple method to determine PVR using measurements performed at the time of the planning CT scan. A PVR calculation tool was developed using a Microsoft Excel spreadsheet to determine the PTV from three orthogonal dimensions of the seroma cavity and a given margin on the CT scans. The breast volume is estimated from the separation and breast height in five equally spaced CT slices. The PTV e val and whole breast volume were determined for 29 patients from two centres using the spreadsheet calculation tool and compared to volumes delineated on computerised treatment planning systems. Both the PTV e val and whole breast volumes were underestimated by approximately 25% using the spreadsheet. The resulting PVRs were 1.05 +/- 0.35 (mean +/- 1 S D) times larger than the ones determined from planning. Estimations of the PVR using the calculation tool were achievable in around 5 minutes at the time of CT scanning and allow a prompt decision on the suitability of the patients for PBI.

  1. Thermodynamic interrelation between excess limiting partial molar characteristics of a liquid nonelectrolyte

    International Nuclear Information System (INIS)

    Ivanov, Evgeniy V.

    2012-01-01

    Highlights: ► Excess limiting molar volume may be regarded as a solvation-related characteristic. ► Volumetric and enthalpic effects of dissolution are interrelated thermodynamically. ► Possibility to estimate the partial change in solute compressibility is described. - Abstract: On the basis of thermodynamic analysis, it is concluded that the excess limiting partial molar volume, like the excess limiting partial molar enthalpy, can be considered as a solvation-related characteristic of a liquid nonelectrolyte. A thermodynamically grounded interrelation between standard volumetric and enthalpic effects of solution of a liquid nonelectrolyte (or series of nonelectrolytes) is suggested.

  2. Cerebral blood flow in temporal lobe epilepsy: a partial volume correction study

    International Nuclear Information System (INIS)

    Giovacchini, Giampiero; Bonwetsch, Robert; Theodore, William H.; Herscovitch, Peter; Carson, Richard E.

    2007-01-01

    Previous studies in temporal lobe epilepsy (TLE) have shown that, owing to brain atrophy, positron emission tomography (PET) can overestimate deficits in measures of cerebral function such as glucose metabolism (CMR glu ) and neuroreceptor binding. The magnitude of this effect on cerebral blood flow (CBF) is unexplored. The aim of this study was to assess CBF deficits in TLE before and after magnetic resonance imaging-based partial volume correction (PVC). Absolute values of CBF for 21 TLE patients and nine controls were computed before and after PVC. In TLE patients, quantitative CMR glu measurements also were obtained. Before PVC, regional values of CBF were significantly (p glu in middle and inferior temporal cortex, fusiform gyrus and hippocampus both before and after PVC. A significant positive relationship between disease duration and AIs for CMR glu , but not CBF, was detected in hippocampus and amygdala, before but not after PVC. PVC should be used for PET CBF measurements in patients with TLE. Reduced blood flow, in contrast to glucose metabolism, is mainly due to structural changes. (orig.)

  3. Estimating the two-particle $K$-matrix for multiple partial waves and decay channels from finite-volume energies

    DEFF Research Database (Denmark)

    Morningstar, Colin; Bulava, John; Singha, Bijit

    2017-01-01

    An implementation of estimating the two-to-two $K$-matrix from finite-volume energies based on the L\\"uscher formalism and involving a Hermitian matrix known as the "box matrix" is described. The method includes higher partial waves and multiple decay channels. Two fitting procedures for estimating...

  4. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    Science.gov (United States)

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  5. Establishment of an open database of realistic simulated data for evaluation of partial volume correction techniques in brain PET/MR

    Energy Technology Data Exchange (ETDEWEB)

    Mota, Ana [Instituto de Biofísica e Engenharia Biomédica, FC-UL, Lisboa (Portugal); Institute of Nuclear Medicine, UCL, London (United Kingdom); Cuplov, Vesna [Instituto de Biofísica e Engenharia Biomédica, FC-UL, Lisboa (Portugal); Schott, Jonathan; Hutton, Brian; Thielemans, Kris [Institute of Nuclear Medicine, UCL, London (United Kingdom); Drobnjak, Ivana [Centre of Medical Image Computing, UCL, London (United Kingdom); Dickson, John [Institute of Nuclear Medicine, UCL, London (United Kingdom); Bert, Julien [INSERM UMR1101, LaTIM, CHRU de Brest, Brest (France); Burgos, Ninon; Cardoso, Jorge; Modat, Marc; Ourselin, Sebastien [Centre of Medical Image Computing, UCL, London (United Kingdom); Erlandsson, Kjell [Institute of Nuclear Medicine, UCL, London (United Kingdom)

    2015-05-18

    The Partial Volume (PV) effect in Positron Emission Tomography (PET) imaging leads to loss in quantification accuracy, which manifests in PV effects (small objects occupy partially the sensitive volume of the imaging instrument, resulting in blurred images). Simultaneous acquisition of PET and Magnetic Resonance Imaging (MRI) produces concurrent metabolic and anatomical information. The latter has proved to be very helpful for the correction of PV effects. Currently, there are several techniques used for PV correction. They can be applied directly during the reconstruction process or as a post-processing step after image reconstruction. In order to evaluate the efficacy of the different PV correction techniques in brain- PET, we are constructing a database of simulated data. Here we present the framework and steps involved in constructing this database. Static 18F-FDG epilepsy and 18F-Florbetapir amyloid dementia PET/MR were selected because of their very different characteristics. The methodology followed was based on four main steps: Image pre-processing, Ground Truth (GT) generation, MRI and PET data simulation and reconstruction. All steps used Open Source software and can therefore be repeated at any centre. The framework as well as the database will be freely accessible. Tools used included GIF, FSL, POSSUM, GATE and STIR. The final data obtained after simulation, involving raw or reconstructed PET data together with corresponding MRI datasets, were close to the original patient data. Besides, there is the advantage that data can be compared with the GT. We indicate several parameters that can be improved and optimized.

  6. Establishment of an open database of realistic simulated data for evaluation of partial volume correction techniques in brain PET/MR

    International Nuclear Information System (INIS)

    Mota, Ana; Cuplov, Vesna; Schott, Jonathan; Hutton, Brian; Thielemans, Kris; Drobnjak, Ivana; Dickson, John; Bert, Julien; Burgos, Ninon; Cardoso, Jorge; Modat, Marc; Ourselin, Sebastien; Erlandsson, Kjell

    2015-01-01

    The Partial Volume (PV) effect in Positron Emission Tomography (PET) imaging leads to loss in quantification accuracy, which manifests in PV effects (small objects occupy partially the sensitive volume of the imaging instrument, resulting in blurred images). Simultaneous acquisition of PET and Magnetic Resonance Imaging (MRI) produces concurrent metabolic and anatomical information. The latter has proved to be very helpful for the correction of PV effects. Currently, there are several techniques used for PV correction. They can be applied directly during the reconstruction process or as a post-processing step after image reconstruction. In order to evaluate the efficacy of the different PV correction techniques in brain- PET, we are constructing a database of simulated data. Here we present the framework and steps involved in constructing this database. Static 18F-FDG epilepsy and 18F-Florbetapir amyloid dementia PET/MR were selected because of their very different characteristics. The methodology followed was based on four main steps: Image pre-processing, Ground Truth (GT) generation, MRI and PET data simulation and reconstruction. All steps used Open Source software and can therefore be repeated at any centre. The framework as well as the database will be freely accessible. Tools used included GIF, FSL, POSSUM, GATE and STIR. The final data obtained after simulation, involving raw or reconstructed PET data together with corresponding MRI datasets, were close to the original patient data. Besides, there is the advantage that data can be compared with the GT. We indicate several parameters that can be improved and optimized.

  7. Partial Molar Volumes of Air-Component Gases in Several Liquid n-Alkanes and 1-Alkanols at 313.15 K

    Czech Academy of Sciences Publication Activity Database

    Izák, Pavel; Cibulka, I.; Heintz, A.

    1995-01-01

    Roč. 109, č. 2 (1995), s. 227-234 ISSN 0378-3812 Keywords : data density * partial molar volume * gas -liquid mixture Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.024, year: 1995

  8. Healthy brain ageing assessed with 18F-FDG PET and age-dependent recovery factors after partial volume effect correction

    Energy Technology Data Exchange (ETDEWEB)

    Bonte, Stijn [IBiTech, Ghent, (Belgium); Ghent University, iMinds - Medical Image and Signal Processing (MEDISIP), Department of Electronics and Information Systems, Ghent (Belgium); University Hospital, Department of Radiology and Nuclear Medicine, Ghent (Belgium); Vandemaele, Pieter; Deblaere, Karel; Goethals, Ingeborg [University Hospital, Department of Radiology and Nuclear Medicine, Ghent (Belgium); Verleden, Stijn; Audenaert, Kurt [University Hospital, Department of Psychiatry, Ghent (Belgium); Holen, Roel van [Ghent University, iMinds - Medical Image and Signal Processing (MEDISIP), Department of Electronics and Information Systems, Ghent (Belgium)

    2017-05-15

    The mechanisms of ageing of the healthy brain are not entirely clarified to date. In recent years several authors have tried to elucidate this topic by using {sup 18}F-FDG positron emission tomography. However, when correcting for partial volume effects (PVE), divergent results were reported. Therefore, it is necessary to evaluate these methods in the presence of atrophy due to ageing. In this paper we first evaluate the performance of two PVE correction techniques with a phantom study: the Rousset method and iterative deconvolution. We show that the ability of the latter method to recover the true activity in a small region decreases with increasing age due to brain atrophy. Next, we have calculated age-dependent recovery factors to correct for this incomplete recovery. These factors were applied to PVE-corrected {sup 18}F-FDG PET scans of healthy subjects for mapping the agedependent metabolism in the brain. Many regions in the brain show a reduced metabolism with ageing, especially in grey matter in the frontal and temporal lobe. An increased metabolism is found in grey matter of the cerebellum and thalamus. Our study resulted in age-dependent recovery factors which can be applied following standard PVE correction methods. Cancelling the effect of atrophy, we found regional changes in {sup 18}F-FDG metabolism with ageing. A decreasing trend is found in the frontal and temporal lobe, whereas an increasing metabolism with ageing is observed in the thalamus and cerebellum.

  9. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: I. Theory, error analysis, and stereologic comparison

    DEFF Research Database (Denmark)

    Lida, H; Law, I; Pakkenberg, B

    2000-01-01

    Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have...... formulated four mathematical models that describe the dynamic behavior of a freely diffusible tracer (H215O) in a region of interest (ROI) incorporating estimates of regional tissue flow that are independent of PVE. The current study was intended to evaluate the feasibility of these models and to establish...... a methodology to accurately quantify regional cerebral blood flow (CBF) corrected for PVE in cortical gray matter regions. Five monkeys were studied with PET after IV H2(15)O two times (n = 3) or three times (n = 2) in a row. Two ROIs were drawn on structural magnetic resonance imaging (MRI) scans and projected...

  10. Towards a universal method for calculating hydration free energies: a 3D reference interaction site model with partial molar volume correction

    International Nuclear Information System (INIS)

    Palmer, David S; Frolov, Andrey I; Ratkova, Ekaterina L; Fedorov, Maxim V

    2010-01-01

    We report a simple universal method to systematically improve the accuracy of hydration free energies calculated using an integral equation theory of molecular liquids, the 3D reference interaction site model. A strong linear correlation is observed between the difference of the experimental and (uncorrected) calculated hydration free energies and the calculated partial molar volume for a data set of 185 neutral organic molecules from different chemical classes. By using the partial molar volume as a linear empirical correction to the calculated hydration free energy, we obtain predictions of hydration free energies in excellent agreement with experiment (R = 0.94, σ = 0.99 kcal mol -1 for a test set of 120 organic molecules). (fast track communication)

  11. Towards a universal method for calculating hydration free energies: a 3D reference interaction site model with partial molar volume correction.

    Science.gov (United States)

    Palmer, David S; Frolov, Andrey I; Ratkova, Ekaterina L; Fedorov, Maxim V

    2010-12-15

    We report a simple universal method to systematically improve the accuracy of hydration free energies calculated using an integral equation theory of molecular liquids, the 3D reference interaction site model. A strong linear correlation is observed between the difference of the experimental and (uncorrected) calculated hydration free energies and the calculated partial molar volume for a data set of 185 neutral organic molecules from different chemical classes. By using the partial molar volume as a linear empirical correction to the calculated hydration free energy, we obtain predictions of hydration free energies in excellent agreement with experiment (R = 0.94, σ = 0.99 kcal mol (- 1) for a test set of 120 organic molecules).

  12. What is the fundamental ion-specific series for anions and cations? Ion specificity in standard partial molar volumes of electrolytes and electrostriction in water and non-aqueous solvents.

    Science.gov (United States)

    Mazzini, Virginia; Craig, Vincent S J

    2017-10-01

    The importance of electrolyte solutions cannot be overstated. Beyond the ionic strength of electrolyte solutions the specific nature of the ions present is vital in controlling a host of properties. Therefore ion specificity is fundamentally important in physical chemistry, engineering and biology. The observation that the strengths of the effect of ions often follows well established series suggests that a single predictive and quantitative description of specific-ion effects covering a wide range of systems is possible. Such a theory would revolutionise applications of physical chemistry from polymer precipitation to drug design. Current approaches to understanding specific-ion effects involve consideration of the ions themselves, the solvent and relevant interfaces and the interactions between them. Here we investigate the specific-ion effects trends of standard partial molar volumes and electrostrictive volumes of electrolytes in water and eleven non-aqueous solvents. We choose these measures as they relate to bulk properties at infinite dilution, therefore they are the simplest electrolyte systems. This is done to test the hypothesis that the ions alone exhibit a specific-ion effect series that is independent of the solvent and unrelated to surface properties. The specific-ion effects trends of standard partial molar volumes and normalised electrostrictive volumes examined in this work show a fundamental ion-specific series that is reproduced across the solvents, which is the Hofmeister series for anions and the reverse lyotropic series for cations, supporting the hypothesis. This outcome is important in demonstrating that ion specificity is observed at infinite dilution and demonstrates that the complexity observed in the manifestation of specific-ion effects in a very wide range of systems is due to perturbations of solvent, surfaces and concentration on the underlying fundamental series. This knowledge will guide a general understanding of specific

  13. Diffusion of multiple species with excluded-volume effects

    KAUST Repository

    Bruna, Maria; Chapman, S. Jonathan

    2012-01-01

    Stochastic models of diffusion with excluded-volume effects are used to model many biological and physical systems at a discrete level. The average properties of the population may be described by a continuum model based on partial differential equations. In this paper we consider multiple interacting subpopulations/species and study how the inter-species competition emerges at the population level. Each individual is described as a finite-size hard core interacting particle undergoing Brownian motion. The link between the discrete stochastic equations of motion and the continuum model is considered systematically using the method of matched asymptotic expansions. The system for two species leads to a nonlinear cross-diffusion system for each subpopulation, which captures the enhancement of the effective diffusion rate due to excluded-volume interactions between particles of the same species, and the diminishment due to particles of the other species. This model can explain two alternative notions of the diffusion coefficient that are often confounded, namely collective diffusion and self-diffusion. Simulations of the discrete system show good agreement with the analytic results. © 2012 American Institute of Physics.

  14. A simple algorithm for subregional striatal uptake analysis with partial volume correction in dopaminergic PET imaging

    International Nuclear Information System (INIS)

    Lue Kunhan; Lin Hsinhon; Chuang Kehshih; Kao Chihhao, K.; Hsieh Hungjen; Liu Shuhsin

    2014-01-01

    In positron emission tomography (PET) of the dopaminergic system, quantitative measurements of nigrostriatal dopamine function are useful for differential diagnosis. A subregional analysis of striatal uptake enables the diagnostic performance to be more powerful. However, the partial volume effect (PVE) induces an underestimation of the true radioactivity concentration in small structures. This work proposes a simple algorithm for subregional analysis of striatal uptake with partial volume correction (PVC) in dopaminergic PET imaging. The PVC algorithm analyzes the separate striatal subregions and takes into account the PVE based on the recovery coefficient (RC). The RC is defined as the ratio of the PVE-uncorrected to PVE-corrected radioactivity concentration, and is derived from a combination of the traditional volume of interest (VOI) analysis and the large VOI technique. The clinical studies, comprising 11 patients with Parkinson's disease (PD) and 6 healthy subjects, were used to assess the impact of PVC on the quantitative measurements. Simulations on a numerical phantom that mimicked realistic healthy and neurodegenerative situations were used to evaluate the performance of the proposed PVC algorithm. In both the clinical and the simulation studies, the striatal-to-occipital ratio (SOR) values for the entire striatum and its subregions were calculated with and without PVC. In the clinical studies, the SOR values in each structure (caudate, anterior putamen, posterior putamen, putamen, and striatum) were significantly higher by using PVC in contrast to those without. Among the PD patients, the SOR values in each structure and quantitative disease severity ratings were shown to be significantly related only when PVC was used. For the simulation studies, the average absolute percentage error of the SOR estimates before and after PVC were 22.74% and 1.54% in the healthy situation, respectively; those in the neurodegenerative situation were 20.69% and 2

  15. Target volume definition for external beam partial breast radiotherapy: Clinical, pathological and technical studies informing current approaches

    International Nuclear Information System (INIS)

    Kirby, Anna M.; Coles, Charlotte E.; Yarnold, John R.

    2010-01-01

    Partial breast irradiation (PBI) is currently under investigation in several phase III trials and, following a recent consensus statement, its use off-study may increase despite ongoing uncertainty regarding optimal target volume definition. We review the clinical, pathological and technical evidence for target volume definition in external beam partial breast irradiation (EB-PBI). The optimal method of tumour bed (TB) delineation requires X-ray CT imaging of implanted excision cavity wall markers. The definition of clinical target volume (CTV) as TB plus concentric 15 mm margins is based on the anatomical distribution of multifocal and multicentric disease around the primary tumour in mastectomy specimens, and the clinical locations of local tumour relapse (LR) after breast conservation surgery. If the majority of LR originate from foci of residual invasive and/or intraduct disease in the vicinity of the TB after complete microscopic resection, CTV margin logically takes account of the position of primary tumour within the surgical resection specimen. The uncertain significance of independent primary tumours as sources of preventable LR, and of wound healing responses in stimulating LR, increases the difficulties in defining optimal CTV. These uncertainties may resolve after long-term follow-up of current PBI trials. By contrast, a commonly used 10 mm clinical to planning target volume (PTV) margin has a stronger evidence base, although departmental set-up errors need to be confirmed locally. A CTV-PTV margin >10 mm may be required in women with larger breasts and/or large seromas, whilst the role of image-guided radiotherapy with or without TB markers in reducing CTV-PTV margins needs to be explored.

  16. Secondary radiation damage as the main cause for unexpected volume effects: A histopathologic study of the parotid gland

    International Nuclear Information System (INIS)

    Konings, Antonius W.T.; Faber, Hette; Cotteleer, Femmy; Vissink, Arjan; Coppes, Rob P.

    2006-01-01

    Purpose: To elucidate with a histopathological study the mechanism of region-dependent volume effects in the partly irradiated parotid gland of the rat. Methods and Materials: Wistar rats were locally X-irradiated with collimators with conformal radiation portals for 100% volume and 50% cranial/caudal partial volumes. Single doses up to 40 Gy were applied. Parotid saliva samples were collected, and the three lobes of the parotid gland were examined individually on the macro- and micromorphologic level up to 1 year after irradiation. Results: Dose-dependent loss of gland weight was observed 1 year after total or partial X-irradiation. Weight loss of the glands correlated very well with loss of secretory function. Irradiating the cranial 50% volume (implicating a shielded lateral lobe) resulted in substantially more damage in terms of weight loss and loss of secretory function than 50% caudal irradiation (shielding the ventral and dorsal lobe). Histologic examinations of the glands 1 year after irradiation revealed that the shielded lateral lobe was severely affected, in contrast to the shielded ventral and dorsal lobes. Time studies showed that irradiation of the cranial 50% volume caused late development of secondary damage in the shielded lateral lobe, becoming manifest between 240 and 360 days after irradiation. The possible clinical significance of this finding is discussed. Conclusion: It is concluded that the observed region-dependent volume effect for late function loss in the rat parotid gland after partial irradiation is mainly caused by secondary events in the shielded lateral lobe. The most probable first step (primary radiation event) in the development of this secondary damage is radiation exposure to the hilus region (located between the ventral and dorsal lobe). By injuring major excretory ducts and supply routes for blood and nerves in this area, the facility system necessary for proper functioning of the nonexposed lateral lobe is seriously affected

  17. Tools for the analysis of dose optimization: I. Effect-volume histogram

    International Nuclear Information System (INIS)

    Alber, M.; Nuesslin, F.

    2002-01-01

    With the advent of dose optimization algorithms, predominantly for intensity-modulated radiotherapy (IMRT), computer software has progressed beyond the point of being merely a tool at the hands of an expert and has become an active, independent mediator of the dosimetric conflicts between treatment goals and risks. To understand and control the internal decision finding as well as to provide means to influence it, a tool for the analysis of the dose distribution is presented which reveals the decision-making process performed by the algorithm. The internal trade-offs between partial volumes receiving high or low doses are driven by functions which attribute a weight to each volume element. The statistics of the distribution of these weights is cast into an effect-volume histogram (EVH) in analogy to dose-volume histograms. The analysis of the EVH reveals which traits of the optimum dose distribution result from the defined objectives, and which are a random consequence of under- or misspecification of treatment goals. The EVH can further assist in the process of finding suitable objectives and balancing conflicting objectives. If biologically inspired objectives are used, the EVH shows the distribution of local dose effect relative to the prescribed level. (author)

  18. Partial molar volumes and viscosities of aqueous hippuric acid solutions containing LiCl and MnCl2 · 4H2O at 303.15 K

    Science.gov (United States)

    Deosarkar, S. D.; Tawde, P. D.; Zinjade, A. B.; Shaikh, A. I.

    2015-09-01

    Density (ρ) and viscosity (η) of aqueous hippuric acid (HA) solutions containing LiCl and MnCl2 · 4H2O have been studied at 303.15 K in order to understand volumetric and viscometric behavior of these systems. Apparent molar volume (φv) of salts were calculated from density data and fitted to Massons relation and partial molar volumes (φ{v/0}) at infinite dilution were determined. Relative viscosity data has been used to determine viscosity A and B coefficients using Jones-Dole relation. Partial molar volume and viscosity coefficients have been discussed in terms of ion-solvent interactions and overall structural fittings in solution.

  19. Estimating the two-particle K-matrix for multiple partial waves and decay channels from finite-volume energies

    Directory of Open Access Journals (Sweden)

    Colin Morningstar

    2017-11-01

    Full Text Available An implementation of estimating the two-to-two K-matrix from finite-volume energies based on the Lüscher formalism and involving a Hermitian matrix known as the “box matrix” is described. The method includes higher partial waves and multiple decay channels. Two fitting procedures for estimating the K-matrix parameters, which properly incorporate all statistical covariances, are discussed. Formulas and software for handling total spins up to S=2 and orbital angular momenta up to L=6 are obtained for total momenta in several directions. First tests involving ρ-meson decay to two pions include the L=3 and L=5 partial waves, and the contributions from these higher waves are found to be negligible in the elastic energy range.

  20. Quadrupole terms in the Maxwell equations: Born energy, partial molar volume, and entropy of ions.

    Science.gov (United States)

    Slavchov, Radomir I; Ivanov, Tzanko I

    2014-02-21

    A new equation of state relating the macroscopic quadrupole moment density Q to the gradient of the field ∇E in an isotropic fluid is derived: Q = αQ(∇E - U∇·E/3), where the quadrupolarizability αQ is proportional to the squared molecular quadrupole moment. Using this equation of state, a generalized expression for the Born energy of an ion dissolved in quadrupolar solvent is obtained. It turns out that the potential and the energy of a point charge in a quadrupolar medium are finite. From the obtained Born energy, the partial molar volume and the partial molar entropy of a dissolved ion follow. Both are compared to experimental data for a large number of simple ions in aqueous solutions. From the comparison the value of the quadrupolar length LQ is determined, LQ = (αQ/3ɛ)(1/2) = 1-4 Å. Data for ion transfer from aqueous to polar oil solution are analyzed, which allowed for the determination of the quadrupolarizability of nitrobenzene.

  1. Concentration dependence of the partial volume, viscosity, and electric conductivity of solutions of lithium salts in aliphatic alcohols

    International Nuclear Information System (INIS)

    Eliseeva, O.V.; Golubev, V.V.

    2003-01-01

    Concentration dependence of partial volumes, electric conductivity and viscosity of lithium nitrate and chloride solutions in methanol, propanol, isopropanol, butanol, isobutanol, pentanol and isopentanol at 298.15 K were studied by the methods of densimetry, conductometry and viscosimetry. Structural specific features of the solutions studied are discussed on the basis of the calculated volumetric characteristics of the substance dissolved and solvent [ru

  2. Effects of fuel relocation on reflood in a partially-blocked rod bundle

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Jae [School of Mechanical Engineering, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134 (Korea, Republic of); Kim, Jongrok; Kim, Kihwan; Bae, Sung Won [Thermal-Hydraulic Safety Research Division, Korea Atomic Energy Research Division, 111 Daedeok-daero, Yuseong-gu, Daejeon 34057 (Korea, Republic of); Moon, Sang-Ki, E-mail: skmoon@kaeri.re.kr [Thermal-Hydraulic Safety Research Division, Korea Atomic Energy Research Division, 111 Daedeok-daero, Yuseong-gu, Daejeon 34057 (Korea, Republic of)

    2017-02-15

    Ballooning of the fuel rods has been an important issue, since it can influence the coolability of the rod bundle in a large-break loss-of-coolant accident (LBLOCA). Numerous past studies have investigated the effect of blockage geometry on the heat transfer in a partially blocked rod bundle. However, they did not consider the occurrence of fuel relocation and the corresponding effect on two-phase heat transfer. Some fragmented fuel particles located above the ballooned region may drop into the enlarged volume of the balloon. Accordingly, the fuel relocation brings in a local power increase in the ballooned region. The present study’s objective is to investigate the effect of the fuel relocation on the reflood under a LBLOCA condition. Toward this end, experiments were performed in a 5 × 5 partially-blocked rod bundle. Two power profiles were tested: one is a typical cosine shape and the other is the modified shape considering the effect of the fuel relocation. For a typical power shape, the peak temperature in the ballooned rods was lower than that in the intact rods. On the other hand, for the modified power shape, the peak temperature in the ballooned rods was higher than that in the intact rods. Numerical simulations were also performed using the MARS code. The tendencies of the peak clad temperatures were well predicted.

  3. Feasibility and performance of novel software to quantify metabolically active volumes and 3D partial volume corrected SUV and metabolic volumetric products of spinal bone marrow metastases on 18F-FDG-PET/CT.

    Science.gov (United States)

    Torigian, Drew A; Lopez, Rosa Fernandez; Alapati, Sridevi; Bodapati, Geetha; Hofheinz, Frank; van den Hoff, Joerg; Saboury, Babak; Alavi, Abass

    2011-01-01

    Our aim was to assess feasibility and performance of novel semi-automated image analysis software called ROVER to quantify metabolically active volume (MAV), maximum standardized uptake value-maximum (SUV(max)), 3D partial volume corrected mean SUV (cSUV(mean)), and 3D partial volume corrected mean MVP (cMVP(mean)) of spinal bone marrow metastases on fluorine-18 fluorodeoxyglucose-positron emission tomography/computerized tomography ((18)F-FDG-PET/CT). We retrospectively studied 16 subjects with 31 spinal metastases on FDG-PET/CT and MRI. Manual and ROVER determinations of lesional MAV and SUV(max), and repeated ROVER measurements of MAV, SUV(max), cSUV(mean) and cMVP(mean) were made. Bland-Altman and correlation analyses were performed to assess reproducibility and agreement. Our results showed that analyses of repeated ROVER measurements revealed MAV mean difference (D)=-0.03±0.53cc (95% CI(-0.22, 0.16)), lower limit of agreement (LLOA)=-1.07cc, and upper limit of agreement (ULOA)=1.01cc; SUV(max) D=0.00±0.00 with LOAs=0.00; cSUV(mean) D=-0.01±0.39 (95% CI(-0.15, 0.13)), LLOA=-0.76, and ULOA=0.75; cMVP(mean) D=-0.52±4.78cc (95% CI(-2.23, 1.23)), LLOA=-9.89cc, and ULOA=8.86cc. Comparisons between ROVER and manual measurements revealed volume D= -0.39±1.37cc (95% CI (-0.89, 0.11)), LLOA=-3.08cc, and ULOA=2.30cc; SUV(max) D=0.00±0.00 with LOAs=0.00. Mean percent increase in lesional SUV(mean) and MVP(mean) following partial volume correction using ROVER was 84.25±36.00% and 84.45±35.94% , respectively. In conclusion, it is feasible to estimate MAV, SUV(max), cSUV(mean), and cMVP(mean) of spinal bone marrow metastases from (18)F-FDG-PET/CT quickly and easily with good reproducibility via ROVER software. Partial volume correction is imperative, as uncorrected SUV(mean) and MVP(mean) are significantly underestimated, even for large lesions. This novel approach has great potential for practical, accurate, and precise combined structural-functional PET

  4. Switching field of partially exchange-coupled particles

    International Nuclear Information System (INIS)

    Oliva, M.I.; Bertorello, H.R.; Bercoff, P.G.

    2004-01-01

    The magnetization reversal of partially exchange-coupled particles is studied in detail. The starting point is the observation of a complicated phenomenology in the irreversible susceptibility and FORC distribution functions of Ba hexaferrite samples obtained by means of different sintering conditions. Several peaks in the first-order reversal curve (FORC) distribution functions were identified and associated with clusters with different number of particles. The switching fields of these clusters were related to an effective anisotropy constant Keff that depends on the number of particles in the cluster. Keff is linked to the exchange-coupled volume between two neighboring particles and as a weighted mean between the anisotropy constants of the coupled and uncoupled volumes. By using the modified Brown's equation αex=0.322 is obtained.In order to interpret these results, the switching field of a two-particle system with partial exchange coupling is studied. It is assumed that the spins reorientation across the contact plane between the particles is like a Bloch wall. The energy of the system is written in terms of the fraction of volume affected by exchange coupling and the switching fields for both particles are calculated. At small interaction volume fraction each particle inverts its magnetization independently from the other. As the fraction of exchange-coupled volume increases, cooperative effects appear and the two particles invert their magnetization in a cooperative way.The proposed model allows to interpret for the first time the empirical factor αex in terms of physical arguments and also explain the details observed in the FORC distribution function

  5. Partial gravity - Human impacts on facility design

    Science.gov (United States)

    Capps, Stephen; Moore, Nathan

    1990-01-01

    Partial gravity affects the body differently than earth gravity and microgravity environments. The main difference from earth gravity is human locomotion; while the main dfference from microgravity is the specific updown orientation and reach envelopes which increase volume requirements. Much data are available on earth gravity and microgravity design; however, very little information is available on human reactions to reduced gravity levels in IVA situations (without pressure suits). Therefore, if humans commit to permanent lunar habitation, much research should be conducted in the area of partial gravity effects on habitat design.

  6. Partial thyroid arterial embolization for the treatment of hyperthyroidism

    International Nuclear Information System (INIS)

    Brzozowski, Krzysztof; Piasecki, Piotr; Zięcina, Piotr; Frankowska, Emilia; Jaroszuk, Andrzej; Kamiński, Grzegorz; Bogusławska-Walecka, Romana

    2012-01-01

    Background: Hyperactive thyroid gland in patients that are unable to tolerate or accept standard therapy is a common clinical problem. Aim of the study was to evaluate effectiveness of partial thyroid arterial embolization in patients with hyperthyroidism. Material/methods: From May 2004 to November 2005 partial thyroid gland embolization was performed in 15 patients. Mean thyroid gland volume was 162 ml. Embolization of one to three thyriod arteries was performed with the mixture of Histoacryl and Lipiodol. Selective angiography was performed after embolization to ensure that the targeted arteries were completely occluded. Follow-up study covered 12 patients. Results: The embolization procedure was well tolerated by all patients. Three days after embolization fT3 and fT4 levels were higher than before the procedure. Further laboratory tests showed quick reversal to near-normal or normal levels of thyroid hormones. 12 weeks follow-up showed: normal serum levels of fT3, fT4 and TSH in 9 of 12 patients (75%), hyperthyroidism in 3 of 12 patients (25%), goiter volume reduction of approximately 32% of its original volume (from 13 to 76.3%), mean thyroid gland volume of 94 ml. One year after embolization 7 of 12 patients required thyreostatic drugs. At two and four years follow-up thyreostatics doses were significantly lower and thyroid tissue was fibrotic. Conclusions: Based on our results the treatment of the thyroid gland goiters using arterial thyroid gland partial embolization may be offered as an effective alternative for patients who will not or cannot accept standard therapy.

  7. An analysis of the nucleon spectrum from lattice partially-quenched QCD

    Energy Technology Data Exchange (ETDEWEB)

    Armour, W. [Swansea University, Swansea, SA2 8PP, Wales, U.K.; Allton, C. R. [Swansea University, Swansea, SA2 8PP, Wales, U.K.; Leinweber, Derek B. [Univ. of Adelaide, SA (Australia); Thomas, Anthony W. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); College of William and Mary, Williamsburg, VA (United States); Young, Ross D. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2010-09-01

    The chiral extrapolation of the nucleon mass, Mn, is investigated using data coming from 2-flavour partially-quenched lattice simulations. The leading one-loop corrections to the nucleon mass are derived for partially-quenched QCD. A large sample of lattice results from the CP-PACS Collaboration is analysed, with explicit corrections for finite lattice spacing artifacts. The extrapolation is studied using finite range regularised chiral perturbation theory. The analysis also provides a quantitative estimate of the leading finite volume corrections. It is found that the discretisation, finite-volume and partial quenching effects can all be very well described in this framework, producing an extrapolated value of Mn in agreement with experiment. This procedure is also compared with extrapolations based on polynomial forms, where the results are less encouraging.

  8. PARTIAL REINFORCEMENT (ACQUISITION) EFFECTS WITHIN SUBJECTS.

    Science.gov (United States)

    AMSEL, A; MACKINNON, J R; RASHOTTE, M E; SURRIDGE, C T

    1964-03-01

    Acquisition performance of 22 rats in a straight alley runway was examined. The animals were subjected to partial reinforcement when the alley was black (B+/-) and continuous reinforcement when it was white (W+). The results indicated (a) higher terminal performance, for partial as against continuous reinforcement conditions, for starting-time and running-time measures, and (b) lower terminal performance under partial conditions for a goal-entry-time measure. These results confirm within subjects an effect previously demonstrated, in the runway, only in between-groups tests, where one group is run under partial reinforcement and a separate group is run under continuous reinforcement in the presence of the same external stimuli. Differences between the runway situation, employing a discrete-trial procedure and performance measures at three points in the response chain, and the Skinner box situation, used in its free-operant mode with a single performance measure, are discussed in relation to the present findings.

  9. The partial-reinforcement extinction effect and the contingent-sampling hypothesis.

    Science.gov (United States)

    Hochman, Guy; Erev, Ido

    2013-12-01

    The partial-reinforcement extinction effect (PREE) implies that learning under partial reinforcements is more robust than learning under full reinforcements. While the advantages of partial reinforcements have been well-documented in laboratory studies, field research has failed to support this prediction. In the present study, we aimed to clarify this pattern. Experiment 1 showed that partial reinforcements increase the tendency to select the promoted option during extinction; however, this effect is much smaller than the negative effect of partial reinforcements on the tendency to select the promoted option during the training phase. Experiment 2 demonstrated that the overall effect of partial reinforcements varies inversely with the attractiveness of the alternative to the promoted behavior: The overall effect is negative when the alternative is relatively attractive, and positive when the alternative is relatively unattractive. These results can be captured with a contingent-sampling model assuming that people select options that provided the best payoff in similar past experiences. The best fit was obtained under the assumption that similarity is defined by the sequence of the last four outcomes.

  10. Altitude Acclimatization and Blood Volume: Effects of Exogenous Erythrocyte Volume Expansion

    National Research Council Canada - National Science Library

    Sawka, M

    1996-01-01

    ...: (a) altitude acclimatization effects on erythrocyte volume and plasma volume; (b) if exogenous erythrocyte volume expansion alters subsequent erythrocyte volume and plasma volume adaptations; (c...

  11. The Effect of Volume of Transaction On The Intention Towards Tax E-filing

    Directory of Open Access Journals (Sweden)

    Aziz Saliza Abdul

    2017-01-01

    Full Text Available Volume of transaction is specifically referring to number of clients or return forms dealing by tax agents/preparers. This variable does play role even though there is less empirical evidence on this matter. This paper is basically to explore the effect of volume of transaction that could possibly influence the acceptance of tax e-filing system as it did in other areas of transaction i.e. court cases. Undoubtedly, it is proved to be significantly influenced the behavioural intention towards tax e-filing acceptability in Malaysia. The tax agents/preparers are randomly selected in this study from the list provided in the Inland Revenue Board of Malaysia (IRBM website. The responds are analysed via Partial Least Square (PLS method which produce the significant results among the low and high volume of transaction of tax e-filing which support the fact that volume does matter in the decision of acceptability of tax e-filing system in Malaysia.

  12. Does partial expander deflation exacerbate the adverse effects of radiotherapy in two-stage breast reconstruction?

    Science.gov (United States)

    Celet Ozden, Burcu; Guven, Erdem; Aslay, Isik; Kemikler, Gonul; Olgac, Vakur; Soluk Tekkesin, Merva; Serarslan, Bengul; Tumerdem Ulug, Burcak; Bilgin Karabulut, Aylin; Arinci, Atilla; Emekli, Ufuk

    2012-02-20

    The optimum protocol for expander volume adjustment with respect to the timing and application of radiotherapy remains controversial. Eighteen New Zealand rabbits were divided into three groups. Metallic port integrated anatomic breast expanders of 250 cc were implanted on the back of each animal and controlled expansion was performed. Group I underwent radiotherapy with full expanders while in Group II, expanders were partially deflated immediately prior to radiotherapy. Control group did not receive radiotherapy.The changes in blood flow at different volume adjustments were investigated in Group II by laser Doppler flowmetry. Variations in the histopathologic properties of the irradiated tissues including the skin, capsule and the pocket floor, were compared in the biopsy specimens taken from different locations in each group. A significant increase in skin blood flow was detected in Group II with partial expander deflation. Overall, histopathologic exam revealed aggravated findings of chronic radiodermatitis (epidermal atrophy, dermal inflammation and fibrosis, neovascularisation and vascular changes as well as increased capsule thickness) especially around the lower expander pole, in Group II. Expander deflation immediately prior to radiotherapy, may augment the adverse effects, especially in the lower expander pole, possibly via enhanced radiosensitization due to a relative increase in the blood flow and tissue oxygenation.

  13. Does partial expander deflation exacerbate the adverse effects of radiotherapy in two-stage breast reconstruction?

    Directory of Open Access Journals (Sweden)

    Celet Ozden Burcu

    2012-02-01

    Full Text Available Abstract Background The optimum protocol for expander volume adjustment with respect to the timing and application of radiotherapy remains controversial. Methods Eighteen New Zealand rabbits were divided into three groups. Metallic port integrated anatomic breast expanders of 250 cc were implanted on the back of each animal and controlled expansion was performed. Group I underwent radiotherapy with full expanders while in Group II, expanders were partially deflated immediately prior to radiotherapy. Control group did not receive radiotherapy. The changes in blood flow at different volume adjustments were investigated in Group II by laser Doppler flowmetry. Variations in the histopathologic properties of the irradiated tissues including the skin, capsule and the pocket floor, were compared in the biopsy specimens taken from different locations in each group. Results A significant increase in skin blood flow was detected in Group II with partial expander deflation. Overall, histopathologic exam revealed aggravated findings of chronic radiodermatitis (epidermal atrophy, dermal inflammation and fibrosis, neovascularisation and vascular changes as well as increased capsule thickness especially around the lower expander pole, in Group II. Conclusions Expander deflation immediately prior to radiotherapy, may augment the adverse effects, especially in the lower expander pole, possibly via enhanced radiosensitization due to a relative increase in the blood flow and tissue oxygenation.

  14. Brachytherapy Partial Breast Irradiation: Analyzing Effect of Source Configurations on Dose Metrics Relevant to Toxicity

    International Nuclear Information System (INIS)

    Cormack, Robert A.; Devlin, Phillip M.

    2008-01-01

    Purpose: Recently, the use of partial breast irradiation (PBI) for patients with early-stage breast cancer with low-risk factors has increased. The volume of the high-dose regions has been correlated with toxicity in interstitial treatment. Although no such associations have been made in applicator-based experience, new applicators are being developed that use complex noncentered source configurations. This work studied the effect of noncentered source placements on the volume of the high-dose regions around a spherical applicator. Methods and Materials: Many applicator configurations were numerically simulated for a range of inflation radii. For each configuration, a dose homogeneity index was used as a dose metric to measure the volume of the high-dose region. Results: All multisource configurations examined resulted in an increase of the high-dose region compared with a single-center source. The resulting decrease in the prescription dose homogeneity index was more pronounced for sources further from the center of the applicator, and the effect was reduced as the number of dwell locations was increased. Conclusion: The geometries of particular applicators were not considered to achieve a more general result. On the basis of the calculations of this work, it would appear that treatment using noncentered dwell locations will lead to an increase in the volume of the high-dose regions

  15. Impact of motion compensation and partial volume correction for 18F-NaF PET/CT imaging of coronary plaque

    Science.gov (United States)

    Cal-González, J.; Tsoumpas, C.; Lassen, M. L.; Rasul, S.; Koller, L.; Hacker, M.; Schäfers, K.; Beyer, T.

    2018-01-01

    Recent studies have suggested that 18F-NaF-PET enables visualization and quantification of plaque micro-calcification in the coronary tree. However, PET imaging of plaque calcification in the coronary arteries is challenging because of the respiratory and cardiac motion as well as partial volume effects. The objective of this work is to implement an image reconstruction framework, which incorporates compensation for respiratory as well as cardiac motion (MoCo) and partial volume correction (PVC), for cardiac 18F-NaF PET imaging in PET/CT. We evaluated the effect of MoCo and PVC on the quantification of vulnerable plaques in the coronary arteries. Realistic simulations (Biograph TPTV, Biograph mCT) and phantom acquisitions (Biograph mCT) were used for these evaluations. Different uptake values in the calcified plaques were evaluated in the simulations, while three ‘plaque-type’ lesions of 36, 31 and 18 mm3 were included in the phantom experiments. After validation, the MoCo and PVC methods were applied in four pilot NaF-PET patient studies. In all cases, the MoCo-based image reconstruction was performed using the STIR software. The PVC was obtained from a local projection (LP) method, previously evaluated in preclinical and clinical PET. The results obtained show a significant increase of the measured lesion-to-background ratios (LBR) in the MoCo  +  PVC images. These ratios were further enhanced when using directly the tissue-activities from the LP method, making this approach more suitable for the quantitative evaluation of coronary plaques. When using the LP method on the MoCo images, LBR increased between 200% and 1119% in the simulated data, between 212% and 614% in the phantom experiments and between 46% and 373% in the plaques with positive uptake observed in the pilot patients. In conclusion, we have built and validated a STIR framework incorporating MoCo and PVC for 18F-NaF PET imaging of coronary plaques. First results indicate an improved

  16. Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant

    Directory of Open Access Journals (Sweden)

    Ritu Raj Upreti

    2017-02-01

    Full Text Available Purpose: To investigate the interobserver variations in delineation of lumpectomy cavity (LC and clinical target volume (CTV, and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy. Material and methods : Delineation of LC and CTV was done by five radiation oncologists on planning computed tomography (CT scans of 20 patients with intraoperative interstitial breast implant. Cavity visualization index (CVI, four-point index ranging from (0 = poor to (3 = excellent was created and assigned by observers for each patient. In total, 200 contours for all observers and 100 treatment plans were evaluated. Spatial concordance (conformity index, CI common , and CIgen, average shift in the center of mass (COM, and ratio of maximum and minimum volumes (V max /V min of LC and CTV were quantified among all observers and statistically analyzed. Variation in active dwell positions (0.5 cm step for each catheter, total reference air kerma (TRAK, volume enclosed by prescription isodose (V100% among observers and its spatial concordance were analyzed. Results : The mean ± SD CI common of LC and CTV was 0.54 ± 0.09, and 0.58 ± 0.08, respectively. Conformity index tends to increase, shift in COM and V max /V min decrease significantly (p < 0.05, as CVI increased. Out of total 309 catheters, 29.8% catheters had no change, 29.8% and 17.5% catheters had variations of 1 and 2 dwell positions (0.5 cm and 1 cm, respectively. 9.3% catheters shown variations ≥ 10 dwell positions (5 cm. The mean ± SD CI common of V100% was 0.75 ± 0.11. The mean observed V max /V min of prescription isodose and TRAK was 1.18 (range, 1.03 to 1.56 and 1.11 (range, 1.03 to 1.35, respectively. Conclusions : Interobserver variability in delineation of target volume was found to be significantly related to CVI. Smaller variability was observed with excellent visualization of LC. Interobserver variations showed dosimetric

  17. Anatomy-based reconstruction of FDG-PET images with implicit partial volume correction improves detection of hypometabolic regions in patients with epilepsy due to focal cortical dysplasia diagnosed on MRI

    Energy Technology Data Exchange (ETDEWEB)

    Goffin, Karolien; Baete, Kristof; Nuyts, Johan; Laere, Koen van [University Hospital Leuven, Division of Nuclear Medicine and Medical Imaging Center, Leuven (Belgium); Van Paesschen, Wim [University Hospital Leuven, Neurology Department, Leuven (Belgium); Dupont, Patrick [University Hospital Leuven, Division of Nuclear Medicine and Medical Imaging Center, Leuven (Belgium); University Hospital Leuven, Laboratory of Cognitive Neurology, Leuven (Belgium); Palmini, Andre [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre Epilepsy Surgery Program, Hospital Sao Lucas, Porto Alegre (Brazil)

    2010-06-15

    Detection of hypometabolic areas on interictal FDG-PET images for assessing the epileptogenic zone is hampered by partial volume effects. We evaluated the performance of an anatomy-based maximum a-posteriori (A-MAP) reconstruction algorithm which combined noise suppression with correction for the partial volume effect in the detection of hypometabolic areas in patients with focal cortical dysplasia (FCD). FDG-PET images from 14 patients with refractory partial epilepsy were reconstructed using A-MAP and maximum likelihood (ML) reconstruction. In all patients, presurgical evaluation showed that FCD represented the epileptic lesion. Correspondence between the FCD location and regional metabolism on a predefined atlas was evaluated. An asymmetry index of FCD to normal cortex was calculated. Hypometabolism at the FCD location was detected in 9/14 patients (64%) using ML and in 10/14 patients (71%) using A-MAP reconstruction. Hypometabolic areas outside the FCD location were detected in 12/14 patients (86%) using ML and in 11/14 patients (79%) using A-MAP reconstruction. The asymmetry index was higher using A-MAP reconstruction (0.61, ML 0.49, p=0.03). The A-MAP reconstruction algorithm improved visual detection of epileptic FCD on brain FDG-PET images compared to ML reconstruction, due to higher contrast and better delineation of the lesion. This improvement failed to reach significance in our small sample. Hypometabolism outside the lesion is often present, consistent with the observation that the functional deficit zone tends to be larger than the epileptogenic zone. (orig.)

  18. Anatomy-based reconstruction of FDG-PET images with implicit partial volume correction improves detection of hypometabolic regions in patients with epilepsy due to focal cortical dysplasia diagnosed on MRI

    International Nuclear Information System (INIS)

    Goffin, Karolien; Baete, Kristof; Nuyts, Johan; Laere, Koen van; Van Paesschen, Wim; Dupont, Patrick; Palmini, Andre

    2010-01-01

    Detection of hypometabolic areas on interictal FDG-PET images for assessing the epileptogenic zone is hampered by partial volume effects. We evaluated the performance of an anatomy-based maximum a-posteriori (A-MAP) reconstruction algorithm which combined noise suppression with correction for the partial volume effect in the detection of hypometabolic areas in patients with focal cortical dysplasia (FCD). FDG-PET images from 14 patients with refractory partial epilepsy were reconstructed using A-MAP and maximum likelihood (ML) reconstruction. In all patients, presurgical evaluation showed that FCD represented the epileptic lesion. Correspondence between the FCD location and regional metabolism on a predefined atlas was evaluated. An asymmetry index of FCD to normal cortex was calculated. Hypometabolism at the FCD location was detected in 9/14 patients (64%) using ML and in 10/14 patients (71%) using A-MAP reconstruction. Hypometabolic areas outside the FCD location were detected in 12/14 patients (86%) using ML and in 11/14 patients (79%) using A-MAP reconstruction. The asymmetry index was higher using A-MAP reconstruction (0.61, ML 0.49, p=0.03). The A-MAP reconstruction algorithm improved visual detection of epileptic FCD on brain FDG-PET images compared to ML reconstruction, due to higher contrast and better delineation of the lesion. This improvement failed to reach significance in our small sample. Hypometabolism outside the lesion is often present, consistent with the observation that the functional deficit zone tends to be larger than the epileptogenic zone. (orig.)

  19. A comparison of five partial volume correction methods for Tau and Amyloid PET imaging with [18F]THK5351 and [11C]PIB.

    Science.gov (United States)

    Shidahara, Miho; Thomas, Benjamin A; Okamura, Nobuyuki; Ibaraki, Masanobu; Matsubara, Keisuke; Oyama, Senri; Ishikawa, Yoichi; Watanuki, Shoichi; Iwata, Ren; Furumoto, Shozo; Tashiro, Manabu; Yanai, Kazuhiko; Gonda, Kohsuke; Watabe, Hiroshi

    2017-08-01

    To suppress partial volume effect (PVE) in brain PET, there have been many algorithms proposed. However, each methodology has different property due to its assumption and algorithms. Our aim of this study was to investigate the difference among partial volume correction (PVC) method for tau and amyloid PET study. We investigated two of the most commonly used PVC methods, Müller-Gärtner (MG) and geometric transfer matrix (GTM) and also other three methods for clinical tau and amyloid PET imaging. One healthy control (HC) and one Alzheimer's disease (AD) PET studies of both [ 18 F]THK5351 and [ 11 C]PIB were performed using a Eminence STARGATE scanner (Shimadzu Inc., Kyoto, Japan). All PET images were corrected for PVE by MG, GTM, Labbé (LABBE), Regional voxel-based (RBV), and Iterative Yang (IY) methods, with segmented or parcellated anatomical information processed by FreeSurfer, derived from individual MR images. PVC results of 5 algorithms were compared with the uncorrected data. In regions of high uptake of [ 18 F]THK5351 and [ 11 C]PIB, different PVCs demonstrated different SUVRs. The degree of difference between PVE uncorrected and corrected depends on not only PVC algorithm but also type of tracer and subject condition. Presented PVC methods are straight-forward to implement but the corrected images require careful interpretation as different methods result in different levels of recovery.

  20. Volume effect on the radiation injury of rat kidney

    International Nuclear Information System (INIS)

    Lo, Y.-C.; Kutcher, Gerald J.; Ling, Clifton C.

    1996-01-01

    Purpose: To minimize the likelihood of radiation-induced kidney injury in treating tumors, the relationship of tolerance dose and irradiated volume of kidney should be known. We have used a rat model to determine the dose-response relationship when various volumes of the kidney are irradiated. Methods and Materials: Anesthetized adult male rats (CD, 10-12 week old) were irradiated with 250 KV x-rays. The kidney was exteriorized and placed in a jig designed to shield all other tissues. Graded single doses were delivered to each of four volumes: 1/4V (half of one kidney), 1/2V (one whole kidney, or half of each kidney), 3/4V (one and a half kidneys) and 1V, where V is the volume of both kidneys. In addition, to compare radiation injury and surgery, partial nephrectomy was performed for 1/4V, 1/2V and 3/4V. Four to sixteen rats were used for each dose-volume point. The rats have been followed up for 540 days. The endpoints for the damage were: lethality, anemia, glomerular filtration rate, effective renal flow, and histology. Results: We found that: (1) There was a threshold volume for radiation damage; injury did not occur if the volume irradiated was ≤ 1/2V, depending on the endpoints. (2) Median survival times did not depend on the dose when a small volume (i.e., 1/4V or 1/2V) was irradiated. (3) The LD 50 (and the 95% confidence limits) at 450 days were 11.35 (8.08 to 12.13) Gy for 1V, 12.38 (11.08 to 13.40) Gy for 3/4V, 21.16 (17.21 to 26.56) Gy for 1/2V, and 28.80 (21.11 to 65.00) Gy for 1/4V. (4) The ED 50 for animals with hematocrit level ≤0.36 at 365 days was 10.98 (4.96 to 13.67) Gy for 1.0V, and 13.82 (6.16 to 17.97) Gy for 3/4V. For 1/2V, only the 80% confidence limits could be derived, giving ED 50 +40.14 (27.98 to ∞) Gy. (5) The results for all other endpoints were similar to those for hematocrit. (6) The dose response was the same whether to half of each kidney or one whole kidney was irradiated. (7) While the threshold volume for radiation injury

  1. Effect of PEEP and inhaled nitric oxide on pulmonary gas exchange during gaseous and partial liquid ventilation with small volumes of perfluorocarbon.

    Science.gov (United States)

    Max, M; Kuhlen, R; Falter, F; Reyle-Hahn, M; Dembinski, R; Rossaint, R

    2000-04-01

    Partial liquid ventilation, positive end-expiratory pressure (PEEP) and inhaled nitric oxide (NO) can improve ventilation/perfusion mismatch in acute lung injury (ALI). The aim of the present study was to compare gas exchange and hemodynamics in experimental ALI during gaseous and partial liquid ventilation at two different levels of PEEP, with and without the inhalation of nitric oxide. Seven pigs (24+/-2 kg BW) were surfactant-depleted by repeated lung lavage with saline. Gas exchange and hemodynamic parameters were assessed in all animals during gaseous and subsequent partial liquid ventilation at two levels of PEEP (5 and 15 cmH2O) and intermittent inhalation of 10 ppm NO. Arterial oxygenation increased significantly with a simultaneous decrease in cardiac output when PEEP 15 cmH2O was applied during gaseous and partial liquid ventilation. All other hemodynamic parameters revealed no relevant changes. Inhalation of NO and instillation of perfluorocarbon had no additive effects on pulmonary gas exchange when compared to PEEP 15 cmH2O alone. In experimental lung injury, improvements in gas exchange are most distinct during mechanical ventilation with PEEP 15 cmH2O without significantly impairing hemodynamics. Partial liquid ventilation and inhaled NO did not cause an additive increase of PaO2.

  2. Field tests on partial embedment effects (embedment effect tests on soil-structure interaction)

    International Nuclear Information System (INIS)

    Kurimoto, O.; Tsunoda, T.; Inoue, T.; Izumi, M.; Kusakabe, K.; Akino, K.

    1993-01-01

    A series of Model Tests of Embedment Effect on Reactor Buildings has been carried out by the Nuclear Power Engineering Corporation (NUPEC), under the sponsorship of the Ministry of International Trade and lndustry (MITI) of Japan. The nuclear reactor buildings are partially embedded due to conditions for the construction or building arrangement in Japan. It is necessary to verify the partial embedment effects by experiments and analytical studies in order to incorporate the effects in the seismic design. Forced vibration tests, therefore, were performed using a model with several types of embedment. Correlated simulation analyses were also performed and the characteristics of partial embedment effects on soil-structure interaction were evaluated. (author)

  3. Numerical Investigation on Absorption Enhancement of Black Carbon Aerosols Partially Coated With Nonabsorbing Organics

    Science.gov (United States)

    Zhang, Xiaolin; Mao, Mao; Yin, Yan; Wang, Bin

    2018-01-01

    This study numerically evaluates the effects of aerosol microphysics, including coated volume fraction of black carbon (BC), shell/core ratio, and size distribution, on the absorption enhancement (Eab) of polydisperse BC aggregates partially coated by organics, which is calculated by the exact multiple-sphere T-matrix method. The coated volume fraction of BC plays a substantial role in determining the absorption enhancement of partially coated BC aggregates, which typically have an Eab in the range of 1.0-2.0 with a larger value for larger coated volume fraction of BC as the shell/core ratio, BC geometry, and size distribution are fixed. The shell/core ratio, BC geometry, and size distribution have little impact on the Eab of coated BC with small coated volume fraction of BC, while they become significant for large coated volume fraction of BC. The Eab of partially coated BC particles can be slightly less than 1.0 for the large BC in the accumulation mode exhibiting large shell/core ratio and small coated volume fraction of BC, indicating that the absorption shows even slight decrease relative to uncoated BC particles. For partially coated BC aggregates in the accumulation and coarse modes, the refractive index uncertainties of BC result in the Eab differences of less than 9% and 2%, respectively, while those of organics can induce larger variations with the maximum differences up to 22% and 18%, respectively. Our study indicates that accounting for particle coating microphysics, particularly the coated volume fraction of BC, can potentially help to understand the differences in observations of largely variable absorption enhancements over various regions.

  4. More on PT-Symmetry in (Generalized Effect Algebras and Partial Groups

    Directory of Open Access Journals (Sweden)

    J. Paseka

    2011-01-01

    Full Text Available We continue in the direction of our paper on PT-Symmetry in (Generalized Effect Algebras and Partial Groups. Namely we extend our considerations to the setting of weakly ordered partial groups. In this setting, any operator weakly ordered partial group is a pasting of its partially ordered commutative subgroups of linear operators with a fixed dense domain over bounded operators. Moreover, applications of our approach for generalized effect algebras are mentioned.

  5. Cerebral blood flow in temporal lobe epilepsy: a partial volume correction study

    Energy Technology Data Exchange (ETDEWEB)

    Giovacchini, Giampiero [University Milano-Bicocca, Milan (Italy); Bonwetsch, Robert; Theodore, William H. [National Institute of Neurological Diseases and Strokes, Clinical Epilepsy Section, Bethesda, MD (United States); Herscovitch, Peter [National Institutes of Health, PET Department, Clinical Center, Bethesda, MD (United States); Carson, Richard E. [Yale PET Center, New Haven, CT (United States)

    2007-12-15

    Previous studies in temporal lobe epilepsy (TLE) have shown that, owing to brain atrophy, positron emission tomography (PET) can overestimate deficits in measures of cerebral function such as glucose metabolism (CMR{sub glu}) and neuroreceptor binding. The magnitude of this effect on cerebral blood flow (CBF) is unexplored. The aim of this study was to assess CBF deficits in TLE before and after magnetic resonance imaging-based partial volume correction (PVC). Absolute values of CBF for 21 TLE patients and nine controls were computed before and after PVC. In TLE patients, quantitative CMR{sub glu} measurements also were obtained. Before PVC, regional values of CBF were significantly (p<0.05) lower in TLE patients than in controls in all regions, except the fusiform gyrus contralateral to the epileptic focus. After PVC, statistical significance was maintained in only four regions: ipsilateral inferior temporal cortex, bilateral insula and contralateral amygdala. There was no significant difference between patients and controls in CBF asymmetry indices (AIs) in any region before or after PVC. In TLE patients, AIs for CBF were significantly smaller than for CMR{sub glu} in middle and inferior temporal cortex, fusiform gyrus and hippocampus both before and after PVC. A significant positive relationship between disease duration and AIs for CMR{sub glu}, but not CBF, was detected in hippocampus and amygdala, before but not after PVC. PVC should be used for PET CBF measurements in patients with TLE. Reduced blood flow, in contrast to glucose metabolism, is mainly due to structural changes. (orig.)

  6. Optimized statistical parametric mapping for partial-volume-corrected amyloid positron emission tomography in patients with Alzheimer's disease and Lewy body dementia

    Science.gov (United States)

    Oh, Jungsu S.; Kim, Jae Seung; Chae, Sun Young; Oh, Minyoung; Oh, Seung Jun; Cha, Seung Nam; Chang, Ho-Jong; Lee, Chong Sik; Lee, Jae Hong

    2017-03-01

    We present an optimized voxelwise statistical parametric mapping (SPM) of partial-volume (PV)-corrected positron emission tomography (PET) of 11C Pittsburgh Compound B (PiB), incorporating the anatomical precision of magnetic resonance image (MRI) and amyloid β (A β) burden-specificity of PiB PET. First, we applied region-based partial-volume correction (PVC), termed the geometric transfer matrix (GTM) method, to PiB PET, creating MRI-based lobar parcels filled with mean PiB uptakes. Then, we conducted a voxelwise PVC by multiplying the original PET by the ratio of a GTM-based PV-corrected PET to a 6-mm-smoothed PV-corrected PET. Finally, we conducted spatial normalizations of the PV-corrected PETs onto the study-specific template. As such, we increased the accuracy of the SPM normalization and the tissue specificity of SPM results. Moreover, lobar smoothing (instead of whole-brain smoothing) was applied to increase the signal-to-noise ratio in the image without degrading the tissue specificity. Thereby, we could optimize a voxelwise group comparison between subjects with high and normal A β burdens (from 10 patients with Alzheimer's disease, 30 patients with Lewy body dementia, and 9 normal controls). Our SPM framework outperformed than the conventional one in terms of the accuracy of the spatial normalization (85% of maximum likelihood tissue classification volume) and the tissue specificity (larger gray matter, and smaller cerebrospinal fluid volume fraction from the SPM results). Our SPM framework optimized the SPM of a PV-corrected A β PET in terms of anatomical precision, normalization accuracy, and tissue specificity, resulting in better detection and localization of A β burdens in patients with Alzheimer's disease and Lewy body dementia.

  7. Generalized solutions of nonlinear partial differential equations

    CERN Document Server

    Rosinger, EE

    1987-01-01

    During the last few years, several fairly systematic nonlinear theories of generalized solutions of rather arbitrary nonlinear partial differential equations have emerged. The aim of this volume is to offer the reader a sufficiently detailed introduction to two of these recent nonlinear theories which have so far contributed most to the study of generalized solutions of nonlinear partial differential equations, bringing the reader to the level of ongoing research.The essence of the two nonlinear theories presented in this volume is the observation that much of the mathematics concernin

  8. Thermodynamic properties of peptide solutions 20. Partial molar volumes and isothermal compressions for some tripeptides of sequence gly-X-gly (X = gly, ala, leu, asn, thr, and tyr) in aqueous solution at T = 298.15 K and p = (10–120) MPa

    International Nuclear Information System (INIS)

    Hedwig, Gavin R.; Høiland, Harald

    2016-01-01

    Highlights: • Sound speeds were measured for aqueous solutions of some tripeptides at high pressures. • Partial molar volumes and isothermal compressions were derived for T = 298.15 K and p = (10–120) MPa. • The partial molar volumes for non-polar amino acid side-chains decrease with increasing pressure. • The partial molar volumes for polar side-chains do not change significantly with increasing pressure. - Abstract: Sound speeds have been measured for aqueous solutions of six tripeptides of sequence glycyl-X-glycine, where X is one of the amino acids glycine, alanine, leucine, asparagine, threonine, and tyrosine at T = 298.15 K and at the pressures p = (10, 20, 40, 60, 80, 100, and 120) MPa. Using methods described in previous work, these sound speeds were used to derive the partial molar volumes at infinite dilution, V_2"o, the partial molar isentropic compressions at infinite dilution, K_S_,_2"o, and the partial molar isothermal compressions at infinite dilution, K"o_T_,_2 {K"o_T_,_2 = −(∂V_2"o/∂p)_T}, for the tripeptides in aqueous solution at the elevated pressures. The results were used to calculate the partial molar volumes and partial molar isothermal compressions for the various amino acid side-chains over the pressure range p = (10–120) MPa.

  9. Incorporating partial shining effects in proton pencil-beam dose calculation

    International Nuclear Information System (INIS)

    Li Yupeng; Zhang Xiaodong; Lii Mingfwu; Sahoo, Narayan; Zhu, Ron X; Gillin, Michael; Mohan, Radhe

    2008-01-01

    A range modulator wheel (RMW) is an essential component in passively scattered proton therapy. We have observed that a proton beam spot may shine on multiple steps of the RMW. Proton dose calculation algorithms normally do not consider the partial shining effect, and thus overestimate the dose at the proximal shoulder of spread-out Bragg peak (SOBP) compared with the measurement. If the SOBP is adjusted to better fit the plateau region, the entrance dose is likely to be underestimated. In this work, we developed an algorithm that can be used to model this effect and to allow for dose calculations that better fit the measured SOBP. First, a set of apparent modulator weights was calculated without considering partial shining. Next, protons spilled from the accelerator reaching the modulator wheel were simplified as a circular spot of uniform intensity. A weight-splitting process was then performed to generate a set of effective modulator weights with the partial shining effect incorporated. The SOBPs of eight options, which are used to label different combinations of proton-beam energy and scattering devices, were calculated with the generated effective weights. Our algorithm fitted the measured SOBP at the proximal and entrance regions much better than the ones without considering partial shining effect for all SOBPs of the eight options. In a prostate patient, we found that dose calculation without considering partial shining effect underestimated the femoral head and skin dose

  10. Survival of the Partial Reinforcement Extinction Effect after Contextual Shifts

    Science.gov (United States)

    Boughner, Robert L.; Papini, Mauricio R.

    2006-01-01

    The effects of contextual shifts on the partial reinforcement extinction effect (PREE) were studied in autoshaping with rats. Experiment 1 established that the two contexts used subsequently were easily discriminable and equally salient. In Experiment 2, independent groups of rats received acquisition training under partial reinforcement (PRF) or…

  11. Effect of different seated positions on lung volume and oxygenation in acute respiratory distress syndrome.

    Science.gov (United States)

    Dellamonica, J; Lerolle, N; Sargentini, C; Hubert, S; Beduneau, G; Di Marco, F; Mercat, A; Diehl, J L; Richard, J C M; Bernardin, G; Brochard, L

    2013-06-01

    Lung volume available for ventilation is markedly decreased during acute respiratory distress syndrome. Body positioning may contribute to increase lung volume and partial verticalization is simple to perform. This study evaluated whether verticalization had parallel effects on oxygenation and end expiratory lung volume (EELV). Prospective multicenter study in 40 mechanically ventilated patients with ALI/ARDS in five university hospital MICUs. We evaluated four 45-min successive trunk position epochs (supine slightly elevated at 15°; semi recumbent with trunk elevated at 45°; seated with trunk elevated at 60° and legs down at 45°; back to supine). Arterial blood gases, EELV measured using the nitrogen washin/washout, and static compliance were measured. Responders were defined by a PaO₂/FiO₂ increase >20 % between supine and seated position. Results are median [25th-75th percentiles]. With median PEEP = 10 cmH₂O, verticalization increased lung volume but only responders (13 patients, 32 %) had a significant increase in EELV/PBW (predicted body weight) compared to baseline. This increase persisted at least partially when patients were positioned back to supine. Responders had a lower EELV/PBW supine [14 mL/kg (13-15) vs. 18 mL/kg (15-27) (p = 0.005)] and a lower compliance [30 mL/cmH₂O (22-38) vs. 42 (30-46) (p = 0.01)] than non-responders. Strain decreased with verticalization for responders. EELV/PBW increase and PaO₂/FiO₂ increase were not correlated. Verticalization is easily achieved and improves oxygenation in approximately 32 % of the patients together with an increase in EELV. Nonetheless, effect of verticalization on EELV/PBW is not predictable by PaO₂/FiO₂ increase, its monitoring may be helpful for strain optimization.

  12. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: II. Normal values and gray matter blood flow response to visual activation

    DEFF Research Database (Denmark)

    Law, I; Iida, H; Holm, S

    2000-01-01

    One of the most limiting factors for the accurate quantification of physiologic parameters with positron emission tomography (PET) is the partial volume effect (PVE). To assess the magnitude of this contribution to the measurement of regional cerebral blood flow (rCBF), the authors have formulated...... or 3D). Furthermore, the authors wanted to measure the activation response in the occipital gray matter compartment, and in doing so test the stability of the PTF, during perturbations of rCBF induced by visual stimulation. Eight dynamic PET scans were acquired per subject (n = 8), each for a duration...... of 6 minutes after IV bolus injection of H2(15)O. Four of these scans were performed using 2D and four using 3D acquisition. Visual stimulation was presented in four scans, and four scans were during rest. Model C was found optimal based on Akaike's Information Criteria (AIC) and had the smallest...

  13. Effective stress principle for partially saturated media

    International Nuclear Information System (INIS)

    McTigue, D.F.; Wilson, R.K.; Nunziato, J.W.

    1984-04-01

    In support of the Nevada Nuclear Waste Storage Investigation (NNWSI) Project, we have undertaken a fundamental study of water migration in partially saturated media. One aspect of that study, on which we report here, has been to use the continuum theory of mixtures to extend the classical notion of effective stress to partially saturated media. Our analysis recovers previously proposed phenomenological representations for the effective stress in terms of the capillary pressure. The theory is illustrated by specializing to the case of linear poroelasticity, for which we calculate the deformation due to the fluid pressure in a static capillary fringe. We then examine the transient consolidation associated with liquid flow induced by an applied surface load. Settlement accompanies this flow as the liquid is redistributed by a nonlinear diffusion process. For material properties characteristic of tuff from the Nevada Test Site, these effects are found to be vanishingly small. 14 references, 7 figures, 1 table

  14. A novel method for the angiographic estimation of the percentage of spleen volume embolized during partial splenic embolization

    International Nuclear Information System (INIS)

    Ou, Ming-Ching; Chuang, Ming-Tsung; Lin, Xi-Zhang; Tsai, Hong-Ming; Chen, Shu-Yuan; Liu, Yi-Sheng

    2013-01-01

    Purpose: To evaluate the efficacy of estimating the volume of spleen embolized in partial splenic embolization (PSE) by measuring the diameters of the splenic artery and its branches. Materials and methods: A total of 43 liver cirrhosis patients (mean age, 62.19 ± 9.65 years) with thrombocytopenia were included. Among these, 24 patients underwent a follow-up CT scan which showed a correlation between angiographic estimation and measured embolized splenic volume. Estimated splenic embolization volume was calculated by a method based on diameters of the splenic artery and its branches. The diameters of each of the splenic arteries and branches were measured via 2D angiographic images. Embolization was performed with gelatin sponges. Patients underwent follow-up with serial measurement of blood counts and liver function tests. The actual volume of embolized spleen was determined by computed tomography (CT) measuring the volumes of embolized and non-embolized spleen two months after PSE. Results: PSE was performed without immediate major complications. The mean WBC count significantly increased from 3.81 ± 1.69 × 10 3 /mm 3 before PSE to 8.56 ± 3.14 × 10 3 /mm 3 at 1 week after PSE (P < 0.001). Mean platelet count significantly increased from 62.00 ± 22.62 × 10 3 /mm 3 before PSE to 95.40 ± 46.29 × 10 3 /mm 3 1 week after PSE (P < 0.001). The measured embolization ratio was positively correlated with estimated embolization ratio (Spearman's rho [ρ] = 0.687, P < 0.001). The mean difference between the actual embolization ratio and the estimated embolization ratio was 16.16 ± 8.96%. Conclusions: The method provides a simple method to quantitatively estimate embolized splenic volume with a correlation of measured embolization ratio to estimated embolization ratio of Spearman's ρ = 0.687

  15. Partial molar volumes of organic solutes in water. XXIII. Cyclic ketones at T = (298 to 573) K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan; Simurka, Lukas; Hnedkovsky, Lubomir; Bolotov, Alexander

    2011-01-01

    Research highlights: → In this study we examine standard molar volumes of aqueous cyclic ketones. → State parameters of measurements were (298 to 573) K and pressures up to 30 MPa. → Differences in behavior of monoketones and cyclohexane-1,4-dione were observed. → Group contribution method was designed and examined. - Abstract: Density data for dilute aqueous solutions of four cyclic ketones (cyclopentanone, cyclohexanone, cycloheptanone, and cyclohexane-1,4-dione) are presented together with standard molar volumes (partial molar volumes at infinite dilution) calculated from the experimental data. The measurements were performed at temperatures from T = 298 K up to T = 573 K. Experimental pressures were close to the saturated vapor pressure of water, and (15 and 30) MPa. The data were obtained using a high-temperature high-pressure flow vibrating-tube densimeter. Experimental standard molar volumes were correlated as a function of temperature and pressure using an empirical polynomial function. Contributions of the molecular structural segments (methylene and carbonyl groups) to the standard molar volume were also evaluated and analyzed.

  16. Aqueous partial molar heat capacities and volumes for NaReO4 and NaTcO4

    International Nuclear Information System (INIS)

    Lemire, R.J.; Saluja, P.P.S.; Campbell, A.B.

    1989-01-01

    As part of the Canadian Nuclear Fuel Waste Management Program, data are required to model the equilibrium thermodynamic behavior of key radionuclides at temperatures above 25 degree C. A flow microcalorimeter/densimeter system has been commissioned to measure heat capacities and densities of solutions containing radioactive species. Measurements for solutions of aqueous NaReO 4 (a common analogue for NaTcO 4 ) were made at seven temperatures (15 to 100 degree C) over the concentration range 0.05 to 0.2 mol·kg -1 . Subsequently, measurements were made for NaTcO 4 solutions under similar conditions. The heat capacity and density data are analyzed using Pitzer's ion-interaction model, and values of the NaReO 4 partial molar heat capacities are compared to literature values based on integral heats of solution. The agreement between the two sets of NaReO 4 data is good below 75 degree C, but only fair at the higher temperatures. Values of the partial molar volumes have also been derived. The uncertainties introduced by using thermodynamic data for ReO 4 - , in the absence of data for TcO 4 - , are discussed

  17. Experimental study of the density and derived volumetric (excess, apparent, and partial molar volumes) properties of aqueous 1-propanol mixtures at temperatures from 298 K to 582 K and pressures up to 40 MPa

    International Nuclear Information System (INIS)

    Abdulagatov, I.M.; Azizov, N.D.

    2014-01-01

    Highlights: • Density of (water + 1-propanol) mixtures. • Excess molar volumes of (water + 1-propanol) mixtures. • Apparent molar volumes of (water + 1-propanol) mixtures. -- Abstract: Densities of (water + 1-propanol) mixtures have been measured over the temperature range from 298 K to 582 K and at pressures up to 40 MPa using the constant-volume piezometer immersed in a precision liquid thermostat. The measurements were made for six compositions of (0.869, 2.465, 2.531, 7.407, 14.377, and 56.348) mol · kg −1 of 1-propanol. The expanded uncertainty of the density, pressure, temperature, and concentration measurements at the 95% confidence level with a coverage factor of k = 2 is estimated to be 0.06%, 0.05%, 15 mK, and 0.015%, respectively. The derived volumetric properties such as excess (V m E ), apparent (V Φ ), and partial (V ¯ 2 ∞ ) molar volumes were calculated using the measured values of density for the mixture and for pure components (water and 1-propanol). The concentration dependences of the apparent molar volumes were extrapolated to zero concentration to yield the partial molar volumes of 1-propanol at infinite dilution (V ¯ 2 ∞ ). The temperature, pressure, and concentration dependence of density and derived properties of the mixture were studied. All experimental and derived properties (excess, apparent, and partial molar volumes) were compared with the reported data by other authors. The small and negative values of excess molar volume for the mixtures were found at all experimental temperatures, pressures, and over the entire concentration range. The excess molar volume minimum is found at concentration about 0.4 mole fraction of 1-propanol. The concentration minimum of the derived apparent molar volumes V Φ near the 2.5 mol · kg −1 (dilute mixture) was observed

  18. Effect of oxygen partial pressure on production of animal virus (VSV)

    OpenAIRE

    Lim, Hyun S.; Chang, Kern H.; Kim, Jung H.

    1999-01-01

    The effect of oxygen partial pressure on viral replication was investigated with Vero/VSV system. At 10% oxygen partial pressure in spinner culture, VSV titer was significantly increased 130 fold compared to that obtained at 21%. A similar result was obtained for viral production in 1liter bioreactor. This implies that oxygen partial pressure during viral production has to be low. In low oxygen partial pressure, malondialdehyde concentration was decreased about 5 fold. Thus, low oxygen partia...

  19. Effects of respiratory rate and tidal volume on gas exchange in total liquid ventilation.

    Science.gov (United States)

    Bull, Joseph L; Tredici, Stefano; Fujioka, Hideki; Komori, Eisaku; Grotberg, James B; Hirschl, Ronald B

    2009-01-01

    Using a rabbit model of total liquid ventilation (TLV), and in a corresponding theoretical model, we compared nine tidal volume-respiratory rate combinations to identify a ventilator strategy to maximize gas exchange, while avoiding choked flow, during TLV. Nine different ventilation strategies were tested in each animal (n = 12): low [LR = 2.5 breath/min (bpm)], medium (MR = 5 bpm), or high (HR = 7.5 bpm) respiratory rates were combined with a low (LV = 10 ml/kg), medium (MV = 15 ml/kg), or high (HV = 20 ml/kg) tidal volumes. Blood gases and partial pressures, perfluorocarbon gas content, and airway pressures were measured for each combination. Choked flow occurred in all high respiratory rate-high volume animals, 71% of high respiratory rate-medium volume (HRMV) animals, and 50% of medium respiratory rate-high volume (MRHV) animals but in no other combinations. Medium respiratory rate-medium volume (MRMV) resulted in the highest gas exchange of the combinations that did not induce choke. The HRMV and MRHV animals that did not choke had similar or higher gas exchange than MRMV. The theory predicted this behavior, along with spatial and temporal variations in alveolar gas partial pressures. Of the combinations that did not induce choked flow, MRMV provided the highest gas exchange. Alveolar gas transport is diffusion dominated and rapid during gas ventilation but is convection dominated and slow during TLV. Consequently, the usual alveolar gas equation is not applicable for TLV.

  20. Effects of partial volume correction on discrimination between very early Alzheimer's dementia and controls using brain perfusion SPECT

    International Nuclear Information System (INIS)

    Kanetaka, Hidekazu; Matsuda, Hiroshi; Ohnishi, Takashi; Imabayashi, Etsuko; Tanaka, Fumiko; Asada, Takashi; Yamashita, Fumio; Nakano, Seigo; Takasaki, Masaru

    2004-01-01

    We assessed the accuracy of brain perfusion single-photon emission computed tomography (SPECT) in discriminating between patients with probable Alzheimer's disease (AD) at the very early stage and age-matched controls before and after partial volume correction (PVC). Three-dimensional MRI was used for PVC. We randomly divided the subjects into two groups. The first group, comprising 30 patients and 30 healthy volunteers, was used to identify the brain area with the most significant decrease in regional cerebral blood flow (rCBF) in patients compared with normal controls based on the voxel-based analysis of a group comparison. The second group, comprising 31 patients and 31 healthy volunteers, was used to study the improvement in diagnostic accuracy provided by PVC. A Z score map for a SPECT image of a subject was obtained by comparison with mean and standard deviation SPECT images of the healthy volunteers for each voxel after anatomical standardization and voxel normalization to global mean or cerebellar values using the following equation: Z score = ([control mean]-[individual value])/(control SD). Analysis of receiver operating characteristics curves for a Z score discriminating AD and controls in the posterior cingulate gyrus, where a significant decrease in rCBF was identified in the first group, showed that the PVC significantly enhanced the accuracy of the SPECT diagnosis of very early AD from 73.9% to 83.7% with global mean normalization. The PVC mildly enhanced the accuracy from 73.1% to 76.3% with cerebellar normalization. This result suggests that early diagnosis of AD requires PVC in a SPECT study. (orig.)

  1. An analysis of the nucleon spectrum from lattice partially-quenched QCD.

    Energy Technology Data Exchange (ETDEWEB)

    Armour, W.; Allton, C. R.; Leinweber, D. B.; Thomas, A. W.; Young, R. D.; Physics; Swansea Univ.; Univ. of Adelaide; Coll. of William and Mary

    2010-09-01

    The chiral extrapolation of the nucleon mass, M{sub n}, is investigated using data coming from 2-flavour partially-quenched lattice simulations. A large sample of lattice results from the CP-PACS Collaboration is analysed using the leading one-loop corrections, with explicit corrections for finite lattice spacing artifacts. The extrapolation is studied using finite-range regularised chiral perturbation theory. The analysis also provides a quantitative estimate of the leading finite volume corrections. It is found that the discretisation, finite volume and partial quenching effects can all be very well described in this framework, producing an extrapolated value of Mn in agreement with experiment. Furthermore, determinations of the low energy constants of the nucleon mass's chiral expansion are in agreement with previous methods, but with significantly reduced errors. This procedure is also compared with extrapolations based on polynomial forms, where the results are less encouraging.

  2. An analysis of the nucleon spectrum from lattice partially-quenched QCD

    Energy Technology Data Exchange (ETDEWEB)

    Armour, W. [Department of Physics, Swansea University, Swansea SA2 8PP, Wales (United Kingdom); Allton, C.R., E-mail: c.allton@swan.ac.u [Department of Physics, Swansea University, Swansea SA2 8PP, Wales (United Kingdom); Leinweber, D.B. [Special Research Centre for the Subatomic Structure of Matter (CSSM), School of Chemistry and Physics, University of Adelaide, 5005 (Australia); Thomas, A.W. [Jefferson Lab, 12000 Jefferson Ave., Newport News, VA 23606 (United States); College of William and Mary, Williamsburg, VA 23187 (United States); Young, R.D. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2010-09-01

    The chiral extrapolation of the nucleon mass, M{sub n}, is investigated using data coming from 2-flavour partially-quenched lattice simulations. A large sample of lattice results from the CP-PACS Collaboration is analysed using the leading one-loop corrections, with explicit corrections for finite lattice spacing artifacts. The extrapolation is studied using finite-range regularised chiral perturbation theory. The analysis also provides a quantitative estimate of the leading finite volume corrections. It is found that the discretisation, finite volume and partial quenching effects can all be very well described in this framework, producing an extrapolated value of M{sub n} in agreement with experiment. Furthermore, determinations of the low energy constants of the nucleon mass's chiral expansion are in agreement with previous methods, but with significantly reduced errors. This procedure is also compared with extrapolations based on polynomial forms, where the results are less encouraging.

  3. Elements of partial differential equations

    CERN Document Server

    Sneddon, Ian Naismith

    1957-01-01

    Geared toward students of applied rather than pure mathematics, this volume introduces elements of partial differential equations. Its focus is primarily upon finding solutions to particular equations rather than general theory.Topics include ordinary differential equations in more than two variables, partial differential equations of the first and second orders, Laplace's equation, the wave equation, and the diffusion equation. A helpful Appendix offers information on systems of surfaces, and solutions to the odd-numbered problems appear at the end of the book. Readers pursuing independent st

  4. First-order partial differential equations

    CERN Document Server

    Rhee, Hyun-Ku; Amundson, Neal R

    2001-01-01

    This first volume of a highly regarded two-volume text is fully usable on its own. After going over some of the preliminaries, the authors discuss mathematical models that yield first-order partial differential equations; motivations, classifications, and some methods of solution; linear and semilinear equations; chromatographic equations with finite rate expressions; homogeneous and nonhomogeneous quasilinear equations; formation and propagation of shocks; conservation equations, weak solutions, and shock layers; nonlinear equations; and variational problems. Exercises appear at the end of mo

  5. Hydrophobic hydration and anomalous excess partial molar volume of tert-butyl alcohol-water mixture studied by quasielastic neutron scattering

    International Nuclear Information System (INIS)

    Nakada, Masaru; Maruyama, Kenji; Misawa, Masakatsu; Yamamuro, Osamu

    2007-01-01

    Quasielastic neutron scattering has been used to investigate the hydration of alcohol clusters in tert-butyl alcohol-water mixture. The measurements were made in a range of alcohol concentration, x TBA , from 0.0 to 0.17 in mole fraction at 25degC. Fraction, α, of water molecules hydrated to fractal-surface of alcohol clusters in tert-butyl alcohol-water mixture was obtained as a function of alcohol concentration. Average hydration number N WS of tert-butyl alcohol molecule was derived from the value of α as a function of alcohol concentration. The value of N WS for an isolated alcohol molecule in water was 19-21. The anomalous excess partial molar volume of tert-butyl alcohol-water mixture was interpreted successfully by applying the same model with the same values of volume parameter as used for 1-propanol-water mixture, δ 1 (=-0.36 cm 3 ·mol -1 ) and δ 2 (=0.60 cm 3 ·mol -1 ). (author)

  6. Solubilities and partial molar volumes of N,N′-dibutyl-oxalamide, N,N′-dihexyl-oxalamide, N,N′-dioctyl-oxalamide in supercritical carbon dioxide

    International Nuclear Information System (INIS)

    Luo, Jie; Yang, Hai-Jian; Jin, Jing; Chang, Fei

    2012-01-01

    Highlights: ► Three new “CO 2 -philic” compounds were designed and synthesized. ► The tested solubility data were calculated and correlated with two models. ► Satisfactory agreements were obtained between the tested and calculated data. ► AARD was lower than 13% for Chrastil model correlation. ► The partial molar volumes V ¯ 2 for each compound were estimated. - Abstract: Three new potent CO 2 -philic compounds were synthesized and their structures were characterized by FT-IR, NMR, and elemental analysis. The solubility of the three compounds in supercritical CO 2 was determined at T = (313 to 353) K from 9.1 MPa to 15.0 MPa. The experimental data were correlated with two density-based models proposed by Bartle and Chrastil, and the calculated results showed good agreement with the tested data. The calculated data by Bartle model differed from the measured values by (6.76 to 9.60)%, and the average value of absolute relative deviations (AARD) with Chrastil model were observed to be between (7.42 to 12.27)%. Furthermore, solubility data were also utilized to estimate the partial molar volume V ¯ 2 for each compound in the supercritical phase using the theory developed by Kumar and Johnston.

  7. A novel method for the angiographic estimation of the percentage of spleen volume embolized during partial splenic embolization

    Energy Technology Data Exchange (ETDEWEB)

    Ou, Ming-Ching; Chuang, Ming-Tsung [Department of Diagnostic Radiology, National Cheng-Kung University Hospital, No. 138 Sheng Li Road, Tainan 704, Taiwan, ROC (China); Lin, Xi-Zhang [Department of Internal Medicine, National Cheng-Kung University Hospital, No. 138 Sheng Li Road, Tainan 704, Taiwan, ROC (China); Tsai, Hong-Ming; Chen, Shu-Yuan [Department of Diagnostic Radiology, National Cheng-Kung University Hospital, No. 138 Sheng Li Road, Tainan 704, Taiwan, ROC (China); Liu, Yi-Sheng, E-mail: taicheng100704@yahoo.com.tw [Department of Diagnostic Radiology, National Cheng-Kung University Hospital, No. 138 Sheng Li Road, Tainan 704, Taiwan, ROC (China)

    2013-08-15

    Purpose: To evaluate the efficacy of estimating the volume of spleen embolized in partial splenic embolization (PSE) by measuring the diameters of the splenic artery and its branches. Materials and methods: A total of 43 liver cirrhosis patients (mean age, 62.19 ± 9.65 years) with thrombocytopenia were included. Among these, 24 patients underwent a follow-up CT scan which showed a correlation between angiographic estimation and measured embolized splenic volume. Estimated splenic embolization volume was calculated by a method based on diameters of the splenic artery and its branches. The diameters of each of the splenic arteries and branches were measured via 2D angiographic images. Embolization was performed with gelatin sponges. Patients underwent follow-up with serial measurement of blood counts and liver function tests. The actual volume of embolized spleen was determined by computed tomography (CT) measuring the volumes of embolized and non-embolized spleen two months after PSE. Results: PSE was performed without immediate major complications. The mean WBC count significantly increased from 3.81 ± 1.69 × 10{sup 3}/mm{sup 3} before PSE to 8.56 ± 3.14 × 10{sup 3}/mm{sup 3} at 1 week after PSE (P < 0.001). Mean platelet count significantly increased from 62.00 ± 22.62 × 10{sup 3}/mm{sup 3} before PSE to 95.40 ± 46.29 × 10{sup 3}/mm{sup 3} 1 week after PSE (P < 0.001). The measured embolization ratio was positively correlated with estimated embolization ratio (Spearman's rho [ρ] = 0.687, P < 0.001). The mean difference between the actual embolization ratio and the estimated embolization ratio was 16.16 ± 8.96%. Conclusions: The method provides a simple method to quantitatively estimate embolized splenic volume with a correlation of measured embolization ratio to estimated embolization ratio of Spearman's ρ = 0.687.

  8. Anatomic partial nephrectomy: technique evolution.

    Science.gov (United States)

    Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S

    2015-03-01

    Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.

  9. Function spaces and partial differential equations 2 volume set

    CERN Document Server

    Taheri, Ali

    2015-01-01

    This is a book written primarily for graduate students and early researchers in the fields of Analysis and Partial Differential Equations (PDEs). Coverage of the material is essentially self-contained, extensive and novel with great attention to details and rigour.

  10. The Partial Molar Volume and Compressibility of FeO in CaO-SiO2 Liquids: Systematic Variation with Fe2+ Coordination Change

    Science.gov (United States)

    Guo, X.; Lange, R. A.; Ai, Y.

    2009-12-01

    Iron is an important element in magmatic liquid, since its concentration can range up to 18% in some basaltic liquids, and it has two oxidation states. In order to model magmatic processes, thermodynamic descriptions of silicate melts must include precise information for both the FeO and Fe2O3 components. Currently, the partial molar volume of FeO is not as well known as that for Fe2O3 because of the difficulty of performing double-bob density measurements under reducing conditions. Yet these data are required in order to convert sound speed measurements on FeO-bearing liquids into compressibility data, which in turn are needed extend density models for magmatic liquids to elevated pressures. Moreover, there is growing evidence from the spectroscopic literature that Fe2+ occurs in 4, 5, and 6-fold coordination in silicate melts, and thus it is possible that the partial molar volume and compressibility of FeO may vary with Fe2+ coordination, and thus with melt composition. To explore these issues, we have conducted both density and relaxed sound speed measurements on liquids in the CaO-FeO-SiO2 system, where the CaO/SiO2 ratio was systematically varied at constant FeO concentration (40 mol%). Density was measured between 1594 and 1813K with the double-bob Archimedean method using molybdenum bobs and crucible in a reducing gas (1%CO-99%Ar) environment. The sounds speeds were measured under similar conditions with a frequency-sweep acoustic interferometer. The derived partial molar volume of FeO increases systematically from 13.7 to 15.2 cm3/mol at 1673 K as the CaO/SiO2 ratio increases and the Fe2+ coordination number decreases. From a comparison with the crystalline volume of FeO (halite structure; 12.06 cm3/mol), which serves as a lower limit for VFeO in silicate liquids when Fe2+ is in 6-fold coordination, we estimate that the average Fe2+ coordination in our experimental melts extends up to values between 5 and 4, consistent with the spectroscopic literature. The

  11. Effect of lung-protective ventilation with lower tidal volumes on clinical outcomes among patients undergoing surgery: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Gu, Wan-Jie; Wang, Fei; Liu, Jing-Chen

    2015-02-17

    In anesthetized patients undergoing surgery, the role of lung-protective ventilation with lower tidal volumes is unclear. We performed a meta-analysis of randomized controlled trials (RCTs) to evaluate the effect of this ventilation strategy on postoperative outcomes. We searched electronic databases from inception through September 2014. We included RCTs that compared protective ventilation with lower tidal volumes and conventional ventilation with higher tidal volumes in anesthetized adults undergoing surgery. We pooled outcomes using a random-effects model. The primary outcome measures were lung injury and pulmonary infection. We included 19 trials (n=1348). Compared with patients in the control group, those who received lung-protective ventilation had a decreased risk of lung injury (risk ratio [RR] 0.36, 95% confidence interval [CI] 0.17 to 0.78; I2=0%) and pulmonary infection (RR 0.46, 95% CI 0.26 to 0.83; I2=8%), and higher levels of arterial partial pressure of carbon dioxide (standardized mean difference 0.47, 95% CI 0.18 to 0.75; I2=65%). No significant differences were observed between the patient groups in atelectasis, mortality, length of hospital stay, length of stay in the intensive care unit or the ratio of arterial partial pressure of oxygen to fraction of inspired oxygen. Anesthetized patients who received ventilation with lower tidal volumes during surgery had a lower risk of lung injury and pulmonary infection than those given conventional ventilation with higher tidal volumes. Implementation of a lung-protective ventilation strategy with lower tidal volumes may lower the incidence of these outcomes. © 2015 Canadian Medical Association or its licensors.

  12. Degradation of self-compacting concrete (SCC) due to sulfuric acid attack: Experiment investigation on the effect of high volume fly ash content

    Science.gov (United States)

    Kristiawan, S. A.; Sunarmasto; Tyas, G. P.

    2016-02-01

    Concrete is susceptible to a variety of chemical attacks. In the sulfuric acid environment, concrete is subjected to a combination of sulfuric and acid attack. This research is aimed to investigate the degradation of self-compacting concrete (SCC) due to sulfuric acid attack based on measurement of compressive strength loss and diameter change. Since the proportion of SCC contains higher cement than that of normal concrete, the vulnerability of this concrete to sulfuric acid attack could be reduced by partial replacement of cement with fly ash at high volume level. The effect of high volume fly ash at 50-70% cement replacement levels on the extent of degradation owing to sulfuric acid will be assessed in this study. It can be shown that an increase in the utilization of fly ash to partially replace cement tends to reduce the degradation as confirmed by less compressive strength loss and diameter change. The effect of fly ash to reduce the degradation of SCC is more pronounced at a later age.

  13. The effect of partially stabilized zirconia on the biological properties of HA/HDPE composites in vitro.

    Science.gov (United States)

    Sadi, A Yari; Shokrgozar, M A; Homaeigohar, S Sh; Hosseinalipour, M; Khavandi, A; Javadpour, J

    2006-05-01

    The effect of partially stabilized zirconia (PSZ) on the biological properties of the hyroxyapatite - high density polyethylene (HA/HDPE) composites was studied by investigating the simultaneous effect of hydroxyapatite and PSZ volume fractions on the in vitro response of human osteoblast cells. The biocompatibility of composite samples with different volume fraction of HA and PSZ powders was assessed by proliferation, alkaline phosphatase (ALP) and cell attachment assays on the osteoblast cell line (G-292) in different time periods. The effect of composites on the behavior of G-292 cells was compared with those of HDPE and TPS (Tissue Culture Poly Styrene as negative control) samples. Results showed a higher proliferation rate of G-292 cells in the presence of composite samples as compared to the HDPE sample after 7 and 14 days of incubation period. ALP production rate in all composite samples was higher than HDPE and TPS samples. The number of adhered cells on the composite samples was higher than the number adhered on the HDPE and TPS samples after the above mentioned incubation periods. These findings indicates that the addition of PSZ does not have any adverse affect on the biocompatibility of HA/HDPE composites. In fact in some experiments PSZ added HA/HDPE composites performed better in proliferation, differentiation and attachment of osteoblastic cells.

  14. 二氧化碳与2-丁醇二元体系在高压下的亨利系数和偏摩尔体积性质计算%Calculation of Henry's coefficient and partial molar volume of carbon dioxide in 2-butanol at elevated pressures

    Institute of Scientific and Technical Information of China (English)

    田爱琴; 孙洪博; 陈文涛; 王琳

    2012-01-01

    Based on vapor-liquid phase equilibria data for CO2+2-butanol binary system from 323K to 353K by constant-volume visual high-pressure cell, the solubility model of CO2 in 2-butanol was established with Krichevsky-Kasarnovsky equation. Henry's coefficients and partial molar volumes of CO2 at infinite dilution were calculated. Meanwhile, Partial molar volumes of CO2 and 2-butanol at equilibrium were calculated from partial molar volumes properties together with Peng-Robinson equation of state and Van der Waals-2 mixed rule. The results showed that Henry's coefficients and partial molar volumes of CO2 at infinite dilution were both the function of temperature, and Henry's coefficients decreased with temperature. The partial molar volumes of CO2 at infinite dilution were negative and the magnitudes decreased with temperature. The calculated effects of partial molar volumes of vapor and liquid phase at equilibrium showed that the partial molar volumes of CO2 and 2-butanol in liquid phase were positive, but in vapor the partial molar volumes of CO2 were negative and the partial molar volumes of 2-butanol were positive. The research provided theoretical basis for deciding supercritical extraction conditions and instructing industrial production.%利用固定体积可视高压釜测量出的在323 K~353 K温度范围内的CO2与2-丁醇二元体系在高压下的汽液相平衡数据,根据Krichevsky-Kasarnovsky方程建立了CO2在液相中的溶解度模型,得到了该二元体系在高压下的亨利系数和CO2在无限稀释溶液中的偏摩尔体积等性质.同时根据偏摩尔体积性质和Peng-Robinson状态方程及Van der Waals-2混合规则来计算该体系在平衡状态下的气、液相的偏摩尔体积.结果表明CO2在2-丁醇中的亨利系数和CO2在无限稀释溶液中的偏摩尔体积均为温度的函数,CO2在2-丁醇中的亨利系数随温度的升高而降低.CO2在无限稀释溶液中的偏摩尔体积(V)1

  15. Apparent and partial molar volumes of long-chain alkyldimethylbenzylammonium chlorides and bromides in aqueous solutions at T=15 deg. C and T=25 deg. C

    International Nuclear Information System (INIS)

    Gonzalez-Perez, A.; Ruso, J.M.; Nimo, J.; Rodriguez, J.R.

    2003-01-01

    Density measurements of dodecyl- (C 12 DBACl), tetradecyl- (C 14 DBACl), hexadecyldimethylbenzylammonium chloride (C 16 DBACl) and of decyl- (C 10 DBABr) and dodecyldimethylbenzylammonium bromide (C 12 DBABr) in aqueous solutions at T=15 deg. C and T=25 deg. C have been carried out. From these results, apparent and partial molar volumes were calculated. Positive deviations from the Debye-Hueckel limiting law provide evidence for limited association at concentrations below the critical micelle concentration. The change of the apparent molar volume upon micellization was calculated. The relevant parameters have been presented in function of the alkyl chain length. Apparent molar volumes of the present compounds in the micellar phase, V phi m , and the change upon micellization, ΔV phi m , have been discussed in terms of temperature and type of counterion

  16. Partial Picture Effects on Children's Memory for Sentences Containing Implicit Information.

    Science.gov (United States)

    Miller, Gloria E.; Pressley, Michael

    1987-01-01

    Two experiments were conducted examining the effects of partial picture adjuncts on young children's coding of information implied in sentences. Developmental differences were found in whether (l) partial pictures facilitated inferencing and (2) pictures containing information not explicitly stated in sentences promoted cue recall of the…

  17. Atomic disintegrations for partially hyperbolic diffeomorphisms

    NARCIS (Netherlands)

    Homburg, Ale Jan

    2017-01-01

    Shub and Wilkinson and Ruelle and Wilkinson studied a class of volume preserving diffeomorphisms on the three dimensional torus that are stably ergodic. The diffeomorphisms are partially hyperbolic and admit an invariant central foliation of circles. The foliation is not absolutely continuous; in

  18. Effect of oral D-tagatose on liver volume and hepatic glycogen accumulation in healthy male volunteers.

    Science.gov (United States)

    Boesch, C; Ith, M; Jung, B; Bruegger, K; Erban, S; Diamantis, I; Kreis, R; Bär, A

    2001-04-01

    Standard toxicity tests with high levels of D-tagatose showed a reversible enlargement of the liver in Sprague-Dawley rats without increase of liver enzymes. The present study tests the hypotheses that partial substitution of dietary sucrose by D-tagatose for 28 days increases the volume of human liver and the concentration of liver glycogen. Twelve healthy, male volunteers were studied in a double-blind crossover study with ingestion of D-tagatose (3x15 g daily) and placebo (sucrose, 3x15 g daily) for periods of 28 days each. Liver volume and glycogen concentration have been determined by magnetic resonance (MR) imaging and spectroscopy, which were accompanied by routine medical examinations. MR examinations before and after the treatments revealed no effects (P>0.05) of treatment, period, or subject for changes in liver volume or glycogen concentration. A steady increase of liver volumes, independent of the D-tagatose or placebo intake, has been observed over the study in parallel with a slight increase in body weight. The treatment with D-tagatose was not associated with clinically relevant changes of the examined clinico-chemical and hematological parameters, including liver enzymes and uric acid. Copyright 2001 Academic Press.

  19. The theory and measurement of partial discharge transients

    DEFF Research Database (Denmark)

    Pedersen, Aage; Crichton, George C; McAllister, Iain Wilson

    1991-01-01

    A theoretical approach to partial discharge transients is presented. This approach is based on the relationship between the charge induced on the measurement electrode by those created in the interelectrode volume during partial discharge activity. The primary sources for these induced charges ar...... electrode systems of practical interest is illustrated. A discussion of the salient features and practical aspects of the theory is included...

  20. Estimation of vapour pressure and partial pressure of subliming ...

    Indian Academy of Sciences (India)

    Administrator

    conditions of (total) pressure by using thermogravimetry under those conditions. Further, from the partial pressure P, it is possible to determine the number of moles of material in the vapour phase using the ideal gas equation, PV = nRT, where P is the partial pressure, V the volume, n number of moles (of the vapour), R the ...

  1. Partial molar volume of paracetamol in water, 0.1 M HCl and 0.154 M NaCl at T = (298.15, 303.15, 308.15 and 310.65) K and at 101.325 kPa

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, Muhammad Javed [Department of Chemistry, Quaid-i-Azam University, Islamabad, Capital 54320 (Pakistan)]. E-mail: mjiqauchem@yahoo.com; Malik, Qaisar Mahmood [Department of Chemistry, Quaid-i-Azam University, Islamabad, Capital 54320 (Pakistan)]. E-mail: qaisar_@hotmail.com

    2005-12-15

    The apparent molar volume of paracetamol (4-acetamidophenol) in water, 0.1 M HCl and 0.154 M NaCl as solvents at (298.15, 303.15, 308.15 and 310.65) K temperatures and at a pressure of 101.325 kPa were determined from the density data obtained with the help of a vibrating-tube Anton Paar DMA-48 densimeter. The partial molar volume, V {sub m}, of paracetamol in these solvents at different temperatures was evaluated by extrapolating the apparent molar volume versus molality plots to m = 0. In addition, the partial molar expansivity, E {sup .}, the isobaric coefficient of thermal expansion, {alpha} {sub p}, and the interaction coefficient, S {sub v}, have also been computed. The expansivity data show dependence of E {sup .} values on the structure of the solute molecules.

  2. Partial molar volume of paracetamol in water, 0.1 M HCl and 0.154 M NaCl at T = (298.15, 303.15, 308.15 and 310.65) K and at 101.325 kPa

    International Nuclear Information System (INIS)

    Iqbal, Muhammad Javed; Malik, Qaisar Mahmood

    2005-01-01

    The apparent molar volume of paracetamol (4-acetamidophenol) in water, 0.1 M HCl and 0.154 M NaCl as solvents at (298.15, 303.15, 308.15 and 310.65) K temperatures and at a pressure of 101.325 kPa were determined from the density data obtained with the help of a vibrating-tube Anton Paar DMA-48 densimeter. The partial molar volume, V m , of paracetamol in these solvents at different temperatures was evaluated by extrapolating the apparent molar volume versus molality plots to m = 0. In addition, the partial molar expansivity, E . , the isobaric coefficient of thermal expansion, α p , and the interaction coefficient, S v , have also been computed. The expansivity data show dependence of E . values on the structure of the solute molecules

  3. Investigation of partial volume effect in different PET/CT systems: a comparison of results using the madeira phantom and the NEMA NU-2 2001 phantom

    International Nuclear Information System (INIS)

    Chipiga, L.; Sydoff, M.; Zvonova, I.; Bernhardsson, C.

    2016-01-01

    Positron emission tomography combined with computed tomography (PET/CT) is a quantitative technique used for diagnosing various diseases and for monitoring treatment response for different types of tumours. However, the accuracy of the data is limited by the spatial resolution of the system. In addition, the so-called partial volume effect (PVE) causes a blurring of image structures, which in turn may cause an underestimation of activity of a structure with high-activity content. In this study, a new phantom, MADEIRA (Minimising Activity and Dose with Enhanced Image quality by Radiopharmaceutical Administrations) for activity quantification in PET and single photon emission computed tomography (SPECT) was used to investigate the influence on the PVE by lesion size and tumour-to-background activity concentration ratio (TBR) in four different PET/CT systems. These measurements were compared with data from measurements with the NEMA NU-2 2001 phantom. The results with the MADEIRA phantom showed that the activity concentration (AC) values were closest to the true values at low ratios of TBR (<10) and reduced to 50 % of the actual AC values at high TBR (30-35). For all scanners, recovery of true values became closer to 1 with an increasing diameter of the lesion. The MADEIRA phantom showed good agreement with the results obtained from measurements with the NEMA NU-2 2001 phantom but allows for a wider range of possibilities in measuring image quality parameters. (authors)

  4. Stochastic partial differential equations an introduction

    CERN Document Server

    Liu, Wei

    2015-01-01

    This book provides an introduction to the theory of stochastic partial differential equations (SPDEs) of evolutionary type. SPDEs are one of the main research directions in probability theory with several wide ranging applications. Many types of dynamics with stochastic influence in nature or man-made complex systems can be modelled by such equations. The theory of SPDEs is based both on the theory of deterministic partial differential equations, as well as on modern stochastic analysis. Whilst this volume mainly follows the ‘variational approach’, it also contains a short account on the ‘semigroup (or mild solution) approach’. In particular, the volume contains a complete presentation of the main existence and uniqueness results in the case of locally monotone coefficients. Various types of generalized coercivity conditions are shown to guarantee non-explosion, but also a systematic approach to treat SPDEs with explosion in finite time is developed. It is, so far, the only book where the latter and t...

  5. Effect of partially purified angiotensin converting enzyme inhibitory ...

    African Journals Online (AJOL)

    This study evaluated the effect of partially-purified angiotensin converting enzyme (ACE) inhibitory proteins obtained from the leaves of Moringa oleifera on blood glucose, serum ACE activity and lipid profile of alloxaninduced diabetic rats. Twenty-five apparently healthy male albino rats were divided into five groups of five ...

  6. Effect of body position on respiratory system volumes in anesthetized red-tailed hawks (Buteo jamaicensis) as measured via computed tomography.

    Science.gov (United States)

    Malka, Shachar; Hawkins, Michelle G; Jones, James H; Pascoe, Peter J; Kass, Philip H; Wisner, Erik R

    2009-09-01

    To determine the effects of body position on lung and air-sac volumes in anesthetized and spontaneously breathing red-tailed hawks (Buteo jamaicensis). 6 adult red-tailed hawks (sex unknown). A crossover study design was used for quantitative estimation of lung and air-sac volumes in anesthetized hawks in 3 body positions: dorsal, right lateral, and sternal recumbency. Lung volume, lung density, and air-sac volume were calculated from helical computed tomographic (CT) images by use of software designed for volumetric analysis of CT data. Effects of body position were compared by use of repeated-measures ANOVA and a paired Student t test. Results for all pairs of body positions were significantly different from each other. Mean +/- SD lung density was lowest when hawks were in sternal recumbency (-677 +/- 28 CT units), followed by right lateral (-647 +/- 23 CT units) and dorsal (-630 +/- 19 CT units) recumbency. Mean lung volume was largest in sternal recumbency (28.6 +/- 1.5 mL), followed by right lateral (27.6 +/- 1.7 mL) and dorsal (27.0 +/- 1.5 mL) recumbency. Mean partial air-sac volume was largest in sternal recumbency (27.0 +/- 19.3 mL), followed by right lateral (21.9 +/- 16.1 mL) and dorsal (19.3 +/- 16.9 mL) recumbency. In anesthetized red-tailed hawks, positioning in sternal recumbency resulted in the greatest lung and air-sac volumes and lowest lung density, compared with positioning in right lateral and dorsal recumbency. Additional studies are necessary to determine the physiologic effects of body position on the avian respiratory system.

  7. Topics in numerical partial differential equations and scientific computing

    CERN Document Server

    2016-01-01

    Numerical partial differential equations (PDEs) are an important part of numerical simulation, the third component of the modern methodology for science and engineering, besides the traditional theory and experiment. This volume contains papers that originated with the collaborative research of the teams that participated in the IMA Workshop for Women in Applied Mathematics: Numerical Partial Differential Equations and Scientific Computing in August 2014.

  8. Effect of dietary citric acid supplementation and partial replacement ...

    African Journals Online (AJOL)

    Jane

    2011-10-24

    Oct 24, 2011 ... evaluate the effect of soybean meal (SBM) as a fishmeal (FM) partial replacement and citric acid (CA) .... temperature, pH and salinity were monitored daily and dissolved .... Digestibility, metabolism and excretion of dietary.

  9. Function spaces and partial differential equations volume 2 : contemporary analysis

    CERN Document Server

    Taheri, Ali

    2015-01-01

    This is a book written primarily for graduate students and early researchers in the fields of Analysis and Partial Differential Equations (PDEs). Coverage of the material is essentially self-contained, extensive and novel with great attention to details and rigour.

  10. The Partial Molar Volume and Thermal Expansivity of Fe2O3 in Alkali Silicate Liquids: Evidence for the Average Coordination of Fe3+

    Science.gov (United States)

    Liu, Q.; Lange, R.

    2003-12-01

    Ferric iron is an important component in magmatic liquids, especially in those formed at subduction zones. Although it has long been known that Fe3+ occurs in four-, five- and six-fold coordination in crystalline compounds, only recently have all three Fe3+ coordination sites been confirmed in silicate glasses utilizing XANES spectroscopy at the Fe K-edge (Farges et al., 2003). Because the density of a magmatic liquid is largely determined by the geometrical packing of its network-forming cations (e.g., Si4+, Al3+, Ti4+, and Fe3+), the capacity of Fe3+ to undergo composition-induced coordination change affects the partial molar volume of the Fe2O3 component, which must be known to calculate how the ferric-ferrous ratio in magmatic liquids changes with pressure. Previous work has shown that the partial molar volume of Fe2O3 (VFe2O3) varies between calcic vs. sodic silicate melts (Mo et al., 1982; Dingwell and Brearley, 1988; Dingwell et al., 1988). The purpose of this study is to extend the data set in order to search for systematic variations in VFe2O3 with melt composition. High temperature (867-1534° C) density measurements were performed on eleven liquids in the Na2O-Fe2O3-FeO-SiO2 (NFS) system and five liquids in the K2O-Fe2O3-FeO-SiO2 (KFS) system using Pt double-bob Archimedean method. The ferric-ferrous ratio in the sodic and potassic liquids at each temperature of density measurement were calculated from the experimentally calibrated models of Lange and Carmichael (1989) and Tangeman et al. (2001) respectively. Compositions range (in mol%) from 4-18 Fe2O3, 0-3 FeO, 12-39 Na2O, 25-37 K2O, and 43-78 SiO2. Our density data are consistent with those of Dingwell et al. (1988) on similar sodic liquids. Our results indicate that for all five KFS liquids and for eight of eleven NFS liquids, the partial molar volume of the Fe2O3 component is a constant (41.57 ñ 0.14 cm3/mol) and exhibits zero thermal expansivity (similar to that for the SiO2 component). This value

  11. 8th International Conference on Partial Least Squares and Related Methods

    CERN Document Server

    Vinzi, Vincenzo; Russolillo, Giorgio; Saporta, Gilbert; Trinchera, Laura

    2016-01-01

    This volume presents state of the art theories, new developments, and important applications of Partial Least Square (PLS) methods. The text begins with the invited communications of current leaders in the field who cover the history of PLS, an overview of methodological issues, and recent advances in regression and multi-block approaches. The rest of the volume comprises selected, reviewed contributions from the 8th International Conference on Partial Least Squares and Related Methods held in Paris, France, on 26-28 May, 2014. They are organized in four coherent sections: 1) new developments in genomics and brain imaging, 2) new and alternative methods for multi-table and path analysis, 3) advances in partial least square regression (PLSR), and 4) partial least square path modeling (PLS-PM) breakthroughs and applications. PLS methods are very versatile methods that are now used in areas as diverse as engineering, life science, sociology, psychology, brain imaging, genomics, and business among both academics ...

  12. [Prevention of side effects and complications after operation for partial ileal bypass].

    Science.gov (United States)

    Mirchuk, K K; Sedletskiĭ, Iu I

    2014-01-01

    Side effects and complications of the application of partial ileal bypass used for dislipidemia were analyzed in 162 patients with atherosclerosis. It was shown, that the partial ileal bypass operation could lead to the development of series of undesirable side effects such as diarrhea, hypovitaminosis B12, off-state intestine enteritis. The application of modification of partial ileal bypass such as formation of ileo-ileoanastomosis 5-6 cm long near ileocecal valve with the maintenance of its functions disposed the diarrhea and minimized the risk of the development of hypovitaminosis B12 after operation. It is possible to prevent the development of enteritis of off-state loop of the small intestine by using microanastomosis between off-state and functioning iliac intestine. The partial ileal bypass operation didn't influence on body weight, wouldn't increase the risk of stone formation in the gallbladder and kidneys. The risk of the development of hypovitaminosis B12 is minimal after operation.

  13. Apparent and standard partial molar heat capacities and volumes of aqueous tartaric acid and its sodium salts at elevated temperature and pressure

    International Nuclear Information System (INIS)

    Xie Wei; Trevani, Liliana; Tremaine, Peter R.

    2004-01-01

    Apparent molar heat capacities and volumes have been determined for aqueous solutions of tartaric acid (H 2 Tar, Tar=C 4 H 4 O 6 ), two buffer solutions of (H 2 Tar/NaHTar) and (NaHTar/Na 2 Tar), and solutions of disodium tartrate (Na 2 Tar) at four temperatures in the range 283.15≤T/K≤328.15 at p=1 MPa. Apparent molar volumes for H 2 Tar(aq) and Na 2 Tar(aq) have been measured at temperatures 377.15≤T/K≤529.15 and p=10.4 MPa. The experimental results have been represented with a model to describe the molality and temperature dependence. Extrapolations to infinite dilution yielded standard partial molar heat capacities C p 0 and volumes V 0 for the species H 2 Tar(aq), HTar - (aq) and Tar 2- (aq) over the range of experimental measurements. The temperature dependence of V 0 for Na 2 Tar(aq) is consistent with other aqueous electrolytes, while that of H 2 Tar(aq) may be anomalous, in that it does not show divergence towards increasingly positive values with increasing temperature

  14. Partial admission effect on the performance and vibration of a supersonic impulse turbine

    Science.gov (United States)

    Lee, Hang Gi; Shin, Ju Hyun; Choi, Chang-Ho; Jeong, Eunhwan; Kwon, Sejin

    2018-04-01

    This study experimentally investigates the effects of partial admission on the performance and vibration outcomes of a supersonic impulse turbine with circular nozzles. The turbine of a turbopump for a gas-generator-type liquid rocket engine in the Korea Space Launch Vehicle-II is of the supersonic impulse type with the partial admission configuration for obtaining a high specific power. Partial admission turbines with a low-flow-rate working gas exhibit benefits over turbines with full admission, such as loss reduction, ease of controllability of the turbine power output, and simple turbine configurations with separate starting sections. However, the radial force of the turbine rotor due to the partial admission causes an increase in turbine vibration. Few experimental studies have previously been conducted regarding the partial admission effects on supersonic impulse turbines with circular nozzles. In the present study, performance tests of supersonic impulse turbines with circular nozzles were conducted for various partial admission ratios using a turbine test facility with high-pressure air in order to investigate the resulting aerodynamic performance and vibration. Four types of turbines with partial admission ratios of 0.17, 0.42, 0.75 and 0.83 were tested. Results show that the efficiencies at the design point increase linearly as the partial admission ratios increase. Moreover, as the velocity ratios increase, the difference in efficiency from the reference turbine with a partial admission ratio of 0.83 becomes increasingly significant, and the magnitudes of these differences are proportional to the square of the velocity ratios. Likewise, the decrease in the partial admission ratio results in an increase in the turbine vibration level owing to the increase in the radial force.

  15. Scintigraphic determination of the spleen volume in case of partial splenectomy for a Minkowski-Chauffard disease. About 15 cases; Determination scintigraphique du volume splenique en cas de splenectomie partielle pour une maladie de Minkowski-Chauffard. A propos de 15 cas

    Energy Technology Data Exchange (ETDEWEB)

    Berehou, F.; Ben Rais, N. [CHU Ibn Sina, Rabat, Service de medecine nucleaire (Morocco); Calzada, M.; Keller, I.; Devaux, J. [Hopital Saint-Antoine, service de medecine nucleaire, 75 - Paris (France)

    2010-07-01

    Splenic scintigraphy with labeled and fragile red blood cells is a simple, reliable, noninvasive and low radiating method to assess at long-term residual splenic volume after partial splenectomy, it is the only treatment for a good quality of life with fewer infections, fewer transfusions and without use of lifelong vaccinations for a chronic illness. (N.C.)

  16. Effect of partial replacement of fishmeal with african yam bean ...

    African Journals Online (AJOL)

    Effect of partial replacement of fishmeal with african yam bean ( Sphenostylis stenocarpa ) meal on eggs, sperm quality and spawning performance of African Catfish Clarias gariepinus (Burchell, 1822) broodstock.

  17. Liver regeneration and restoration of liver function after partial hepatectomy in patients with liver tumors

    International Nuclear Information System (INIS)

    Jansen, P.L.M.; Chamuleau, R.A.F.; Leeuwen, D.J. van; Schippor, H.G.; Busemann-Sokole, E.; Heyde, M.N. van der

    1990-01-01

    Liver regeneration and restoration of liver function were studied in six patients who underwent partial hepatectomy with removal of 30-70% of the liver. Liver volume and liver regeneration were studied by single photon computed tomography (SPECT), using 99m Tc-colloid as tracer. The method was assessed in 11 patients by comparing the pre- and post-operative volume measurement with the volume of the resected liver mass. Liver function was determined by measuring the galactose elimination capacity and the caffeine clearance. After a postoperative follow-up period of 50 days, the liver had regenerated maximally to a volume of 75 ± 2% of the preoperative liver mass. Maximal restoration of liver function was achieved 120 days after operation and amounted to 75 ± 10% for the caffeine clearance and to 100 ± 25% for the galactose elimination capacity. This study shows that SPECT is a useful method for assessing liver regeneration in patients after partial hepatectomy. The study furthermore shows that caffeine clearance correlates well with total liver volume, whereas the galactose elimination capacity overestimates total liver volume after partial hepatectomy. 22 refs

  18. Effects of oxygen partial pressure on Li-air battery performance

    Science.gov (United States)

    Kwon, Hyuk Jae; Lee, Heung Chan; Ko, Jeongsik; Jung, In Sun; Lee, Hyun Chul; Lee, Hyunpyo; Kim, Mokwon; Lee, Dong Joon; Kim, Hyunjin; Kim, Tae Young; Im, Dongmin

    2017-10-01

    For application in electric vehicles (EVs), the Li-air battery system needs an air intake system to supply dry oxygen at controlled concentration and feeding rate as the cathode active material. To facilitate the design of such air intake systems, we have investigated the effects of oxygen partial pressure (≤1 atm) on the performance of the Li-air cell, which has not been systematically examined. The amounts of consumed O2 and evolved CO2 from the Li-air cell are measured with a custom in situ differential electrochemical gas chromatography-mass spectrometry (DEGC-MS). The amounts of consumed O2 suggest that the oxygen partial pressure does not affect the reaction mechanism during discharge, and the two-electron reaction occurs under all test conditions. On the other hand, the charging behavior varies by the oxygen partial pressure. The highest O2 evolution ratio is attained under 70% O2, along with the lowest CO2 evolution. The cell cycle life also peaks at 70% O2 condition. Overall, an oxygen partial pressure of about 0.5-0.7 atm maximizes the Li-air cell capacity and stability at 1 atm condition. The findings here indicate that the appropriate oxygen partial pressure can be a key factor when developing practical Li-air battery systems.

  19. EFFECTS OF DEXAMETHASONE AND PHENIRAMINE MALEATE ON HEMODYNAMIC AND RESPIRATORY PARAMETERS AFTER CEMENTATION IN CEMENTED PARTIAL HIP PROSTHESIS.

    Science.gov (United States)

    Yektaş, Abdulkadir; Gümüş, Funda; Totoz, Tolga; Gül, Nurten; Erkalp, Kerem; Alagöl, Ayşin

    2015-02-01

    To prevent hemodynamic and respiratory changes that are likely to occur during cementation in partial hip prosthesis by prophylactic use of pheniramine maleate and dexamethasone. The study included 40 patients aged between 60 and 85 years with an American Society ofAnesthesiologists (ASA) grade of II-III who underwent partial hip prosthesis. Just after spinal anesthesia, 4 mL normal saline was pushed in patients in Group S, whereas 45.5 mg pheniramine maleate and 8 mg dexamethasone mixture was pushed intravenously in a total volume of 4 mL in patients in Group PD. Amounts of atropine and adrenaline administered after cementation were significantly higher in Group S than in Group PD (P pheniramine maleate and dexamethasone in partial hip prosthesis led to an increase in SpO2 value and a decrease in the utilization of adrenaline and atropine after cementation.

  20. Ultrasound gel minimizes third body debris with partial hardware removal in joint arthroplasty

    Directory of Open Access Journals (Sweden)

    Aidan C. McGrory

    2017-03-01

    Full Text Available Hundreds of thousands of revision surgeries for hip, knee, and shoulder joint arthroplasties are now performed worldwide annually. Partial removal of hardware during some types of revision surgeries may create significant amounts of third body metal, polymer, or bone cement debris. Retained debris may lead to a variety of negative health effects including damage to the joint replacement. We describe a novel technique for the better containment and easier removal of third body debris during partial hardware removal. We demonstrate hardware removal on a hip joint model in the presence and absence of water-soluble gel to depict the reduction in metal debris volume and area of spread.

  1. Defining the Role of Free Flaps in Partial Breast Reconstruction.

    Science.gov (United States)

    Smith, Mark L; Molina, Bianca J; Dayan, Erez; Jablonka, Eric M; Okwali, Michelle; Kim, Julie N; Dayan, Joseph H

    2018-03-01

     Free flaps have a well-established role in breast reconstruction after mastectomy; however, their role in partial breast reconstruction remains poorly defined. We reviewed our experience with partial breast reconstruction to better understand indications for free tissue transfer.  A retrospective review was performed of all patients undergoing partial breast reconstruction at our center between February 2009 and October 2015. We evaluated the characteristics of patients who underwent volume displacement procedures versus volume replacement procedures and free versus pedicled flap reconstruction.  There were 78 partial breast reconstructions, with 52 reductions/tissue rearrangements (displacement group) and 26 flaps (replacement group). Bra cup size and body mass index (BMI) were significantly smaller in the replacement group. Fifteen pedicled and 11 free flaps were performed. Most pedicled flaps (80.0%) were used for lateral or upper pole defects. Most free flaps (72.7%) were used for medial and inferior defects or when there was inadequate donor tissue for a pedicled flap. Complications included hematoma, cellulitis, and one aborted pedicled flap.  Free and pedicled flaps are useful for partial breast reconstruction, particularly in breast cancer patients with small breasts undergoing breast-conserving treatment (BCT). Flap selection depends on defect size, location, and donor tissue availability. Medial defects are difficult to reconstruct using pedicled flaps due to arc of rotation and intervening breast tissue. Free tissue transfer can overcome these obstacles. Confirming negative margins before flap reconstruction ensures harvest of adequate volume and avoids later re-operation. Judicious use of free flaps for oncoplastic reconstruction expands the possibility for breast conservation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Partial differential equations

    CERN Document Server

    Sloan, D; Süli, E

    2001-01-01

    /homepage/sac/cam/na2000/index.html7-Volume Set now available at special set price ! Over the second half of the 20th century the subject area loosely referred to as numerical analysis of partial differential equations (PDEs) has undergone unprecedented development. At its practical end, the vigorous growth and steady diversification of the field were stimulated by the demand for accurate and reliable tools for computational modelling in physical sciences and engineering, and by the rapid development of computer hardware and architecture. At the more theoretical end, the analytical insight in

  3. Water-vapor pressure control in a volume

    Science.gov (United States)

    Scialdone, J. J.

    1978-01-01

    The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.

  4. What is the fundamental ion-specific series for anions and cations? Ion specificity in standard partial molar volumes of electrolytes and electrostriction in water and non-aqueous solvents† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7sc02691a Click here for additional data file.

    Science.gov (United States)

    Mazzini, Virginia

    2017-01-01

    The importance of electrolyte solutions cannot be overstated. Beyond the ionic strength of electrolyte solutions the specific nature of the ions present is vital in controlling a host of properties. Therefore ion specificity is fundamentally important in physical chemistry, engineering and biology. The observation that the strengths of the effect of ions often follows well established series suggests that a single predictive and quantitative description of specific-ion effects covering a wide range of systems is possible. Such a theory would revolutionise applications of physical chemistry from polymer precipitation to drug design. Current approaches to understanding specific-ion effects involve consideration of the ions themselves, the solvent and relevant interfaces and the interactions between them. Here we investigate the specific-ion effects trends of standard partial molar volumes and electrostrictive volumes of electrolytes in water and eleven non-aqueous solvents. We choose these measures as they relate to bulk properties at infinite dilution, therefore they are the simplest electrolyte systems. This is done to test the hypothesis that the ions alone exhibit a specific-ion effect series that is independent of the solvent and unrelated to surface properties. The specific-ion effects trends of standard partial molar volumes and normalised electrostrictive volumes examined in this work show a fundamental ion-specific series that is reproduced across the solvents, which is the Hofmeister series for anions and the reverse lyotropic series for cations, supporting the hypothesis. This outcome is important in demonstrating that ion specificity is observed at infinite dilution and demonstrates that the complexity observed in the manifestation of specific-ion effects in a very wide range of systems is due to perturbations of solvent, surfaces and concentration on the underlying fundamental series. This knowledge will guide a general understanding of specific

  5. Cost-effectiveness of implant-supported mandibular removable partial dentures

    NARCIS (Netherlands)

    Jensen, Charlotte; Ross, Jamila; Feenstra, Talitha L; Raghoebar, Gerry M; Speksnijder, Caroline; Meijer, Henny J A; Cune, Marco S

    ObjectivesThe aim of this study was to conduct a cost-effectiveness analysis comparing conventional removable partial dentures (RPDs) and implant-supported RPDs (ISRPDs) treatment in patients with an edentulous maxilla and a bilateral free-ending situation in the mandible. Material and methodsThirty

  6. Database of normal human cerebral blood flow measured by SPECT: II. Quantification of I-123-IMP studies with ARG method and effects of partial volume correction.

    Science.gov (United States)

    Inoue, Kentaro; Ito, Hiroshi; Shidahara, Miho; Goto, Ryoi; Kinomura, Shigeo; Sato, Kazunori; Taki, Yasuyuki; Okada, Ken; Kaneta, Tomohiro; Fukuda, Hiroshi

    2006-02-01

    The limited spatial resolution of SPECT causes a partial volume effect (PVE) and can lead to the significant underestimation of regional tracer concentration in the small structures surrounded by a low tracer concentration, such as the cortical gray matter of an atrophied brain. The aim of the present study was to determine, using 123I-IMP and SPECT, normal CBF of elderly subjects with and without PVE correction (PVC), and to determine regional differences in the effect of PVC and their association with the regional tissue fraction of the brain. Quantitative CBF SPECT using 123I-IMP was performed in 33 healthy elderly subjects (18 males, 15 females, 54-74 years old) using the autoradiographic method. We corrected CBF for PVE using segmented MR images, and analyzed quantitative CBF and regional differences in the effect of PVC using tissue fractions of gray matter (GM) and white matter (WM) in regions of interest (ROIs) placed on the cortical and subcortical GM regions and deep WM regions. The mean CBF in GM-ROIs were 31.7 +/- 6.6 and 41.0 +/- 8.1 ml/100 g/min for males and females, and in WM-ROIs, 18.2 +/- 0.7 and 22.9 +/- 0.8 ml/100 g/min for males and females, respectively. The mean CBF in GM-ROIs after PVC were 50.9 +/- 12.8 and 65.8 +/- 16.1 ml/100 g/min for males and females, respectively. There were statistically significant differences in the effect of PVC among ROIs, but not between genders. The effect of PVC was small in the cerebellum and parahippocampal gyrus, and it was large in the superior frontal gyrus, superior parietal lobule and precentral gyrus. Quantitative CBF in GM recovered significantly, but did not reach values as high as those obtained by invasive methods or in the H2(15)O PET study that used PVC. There were significant regional differences in the effect of PVC, which were considered to result from regional differences in GM tissue fraction, which is more reduced in the frontoparietal regions in the atrophied brain of the elderly.

  7. Database of normal human cerebral blood flow measured by SPECT. II. Quantification of I-123-IMP studies with ARG method and effects of partial volume correction

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Ito, Hiroshi; Shidahara, Miho

    2006-01-01

    The limited spatial resolution of SPECT causes a partial volume effect (PVE) and can lead to the significant underestimation of regional tracer concentration in the small structures surrounded by a low tracer concentration, such as the cortical gray matter of an atrophied brain. The aim of the present study was to determine, using 123 I-IMP and SPECT, normal cerebral blood flow (CBF) of elderly subjects with and without PVE correction (PVC), and to determine regional differences in the effect of PVC and their association with the regional tissue fraction of the brain. Quantitative CBF SPECT using 123 I-IMP was performed in 33 healthy elderly subjects (18 males, 15 females, 54-74 years old) using the autoradiographic method. We corrected CBF for PVE using segmented MR images, and analyzed quantitative CBF and regional differences in the effect of PVC using tissue fractions of gray matter (GM) and white matter (WM) in regions of interest (ROIs) placed on the cortical and subcortical GM regions and deep WM regions. The mean CBF in GM-ROIs were 31.7±6.6 and 41.0±8.1 ml/100 g/min for males and females, and in WM-ROIs, 18.2±0.7 and 22.9±0.8 ml/100 g/min for males and females, respectively. The mean CBF in GM-ROIs after PVC were 50.9±12.8 and 65.8±16.1 ml/100 g/min for males and females, respectively. There were statistically significant differences in the effect of PVC among ROIs, but not between genders. The effect of PVC was small in the cerebellum and parahippocampal gyrus, and it was large in the superior frontal gyrus, superior parietal lobule and precentral gyrus. Quantitative CBF in GM recovered significantly, but did not reach values as high as those obtained by invasive methods or in the H 2 15 O PET study that used PVC. There were significant regional differences in the effect of PVC, which were considered to result from regional differences in GM tissue fraction, which is more reduced in the frontoparietal regions in the atrophied brain of the elderly

  8. Dosimetric investigation depending on tumor location in patient breast in partial breast irradiation

    International Nuclear Information System (INIS)

    Kim, Min Joo; Park, So Hyun; Jung, Joo Young; Woong, Cho; Suh, Tae Suk

    2012-01-01

    The Partial Breast Irradiation (PBI) technique, which involves radiation beam delivery techniques that use a limited range of treatment volumes, has been a challenging approach that is worthy of consideration compared to whole-breast radiation therapy (WBRT). Because of a small target volumes used in the PBI technique, the radiation dose can be safely delivered to the targeted tissue without the unwanted delivery of radiation to normal breast tissues and organ at risk (OAR), such as contralateral breast, lung and heart.Through PBI technique, better cosmetic outcomes and minimizing damages to OARs could be expected and also the daily dose can be increased with smaller number of fractionation in radiation therapy. The purpose of this study was to evaluate the dosimetric effects according to tumor locations in patient's breast for Partial Breast Irradiation (PBI) technique using three Dimensional Conformal Radiation Therapy (3DCRT), Electron Beam Radiation therapy (EBRT) and Helical-tomotherapy (H-TOMO). Dosimetric comparisons of PBI technique for 3DCRT, EBRT, and H-TOMO depending on the classified tumor locations were performed. H-TOMO delivered the low dose to lager volume to surrounding normal tissue, such as the heart and lungs compared to 3DCRT and EBRT although it had the same degree of target coverage as the other methods (3DCRT, EBRT). EBRT had a curative effect for early-stage breast cancers located in the lower and inner sections (LIQ-S, LIQ-D)

  9. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  10. Two-nucleon higher partial-wave scattering from lattice QCD

    Directory of Open Access Journals (Sweden)

    Evan Berkowitz

    2017-02-01

    Full Text Available We present a determination of nucleon-nucleon scattering phase shifts for ℓ≥0. The S, P, D and F phase shifts for both the spin-triplet and spin-singlet channels are computed with lattice Quantum ChromoDynamics. For ℓ>0, this is the first lattice QCD calculation using the Lüscher finite-volume formalism. This required the design and implementation of novel lattice methods involving displaced sources and momentum-space cubic sinks. To demonstrate the utility of our approach, the calculations were performed in the SU(3-flavor limit where the light quark masses have been tuned to the physical strange quark mass, corresponding to mπ=mK≈800 MeV. In this work, we have assumed that only the lowest partial waves contribute to each channel, ignoring the unphysical partial wave mixing that arises within the finite-volume formalism. This assumption is only valid for sufficiently low energies; we present evidence that it holds for our study using two different channels. Two spatial volumes of V≈(3.5 fm3 and V≈(4.6 fm3 were used. The finite-volume spectrum is extracted from the exponential falloff of the correlation functions. Said spectrum is mapped onto the infinite volume phase shifts using the generalization of the Lüscher formalism for two-nucleon systems.

  11. Effect of cesium seeding on hydrogen negative ion volume production

    International Nuclear Information System (INIS)

    Bacal, M.; Balghiti-Sube, F. El; Elizarov, L. I.; Tontegode, A. J.

    1998-01-01

    The effect of cesium vapor partial pressure on the plasma parameters has been studied in the dc hybrid negative ion source ''CAMEMBERT III.'' The cesium vapor pressure was varied up to 10 -5 Torr and was determined by a surface ionization gauge in the absence of the discharge. The negative ion relative density measured by laser photodetachment in the center of the plasma extraction region increases by a factor of four when the plasma is seeded with cesium. However the plasma density and the electron temperature (determined using a cylindrical electrostatic probe) are reduced by the cesium seeding. As a result, the negative ion density goes up by a factor of two at the lowest hydrogen pressure studied. The velocity of the directed negative ion flow to the plasma electrode, determined from two-laser beam photodetachment experiments, appears to be affected by the cesium seeding. The variation of the extracted negative ion and electron currents versus the plasma electrode bias will also be reported for pure hydrogen and cesium seeded plasmas. The cesium seeding leads to a dramatic reduction of the electron component, which is consistent with the reduced electron density and temperature. The negative ion current is enhanced and a goes through a maximum at plasma electrode bias lower than 1 V. These observations lead to the conclusion that the enhancement of pure volume production occurs in this type of plasma. Possible mechanisms for this type of volume process will be discussed

  12. Turbulence effect on Ohm's law in partially ionized plasmas

    International Nuclear Information System (INIS)

    Numano, M.

    1977-01-01

    An investigation of the effect of nonuniformity on electric current flow in partially ionized plasmas is made. An Ohm's law for a nonuniform plasma was derived, from which Rosa's equation is obtained as a special case. Making use of this new Ohm's law, the effective electrical conductivity and Hall coefficient are determined for isotropically turbulent plasmas. They are found to be in good agreement with the results obtained previously. (author)

  13. The effect of partial shading on dye-sensitized solar cell module characteristics

    International Nuclear Information System (INIS)

    Pan, Bin; Weng, Jian; Chen, Shuanghong; Huang, Yang; Dai, Songyuan

    2014-01-01

    The dye-sensitized solar cell (DSC) is a kind of novel solar cell with prospects for building integrated photovoltaic applications. In some situations, a DSC module may work under partial shading conditions, and subsequently the module temperature and I–V characteristics change. In this work, the effect of partial shading on DSC module characteristics is experimentally studied and the temperature and electric output of the partially shaded DSC module are measured. The variations of module temperature and output performance are analyzed under short circuit conditions and a normal operating mode of charging battery. Furthermore, the stability of the partially shaded DSC module is also evaluated. It is found that the temperature rise of the DSC module caused by partial shading is slower and much smaller than the silicon solar cell, and the characteristics of the single DSC that suffered from short-term shading remain stable. For a DSC module operating in charging mode, the maximum power point and working point change when a shadow appears. (paper)

  14. Partial molar volumes of organic solutes in water. XXIV. Selected alkane-α,ω-diols at temperatures T = 298 K to 573 K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan; Hnědkovský, Lubomír

    2013-01-01

    Highlights: • Standard molar volumes of three alkane-α,ω-diols (C 5 , C 8 , C 9 ) in water are presented. • Data were obtained in the range T from (298 to 573) K and p up to 30 MPa. • Dependences on carbon atom number, temperature, and pressure are analysed. -- Abstract: Density data for dilute aqueous solutions of three alkane-α,ω-diols (pentane-1,5-diol, octane-1,8-diol, nonane-1,9-diol) are presented together with standard molar volumes (partial molar volumes at infinite dilution) calculated from the experimental data. The measurements were performed at temperatures from T = 298 K up to T = 573 K. Experimental pressures were slightly above the saturation vapour pressure of water, and (15 and 30) MPa. The data were obtained using a high-temperature high-pressure flow vibrating-tube densimeter. Measured standard molar volumes were combined with data previously published for other members of the homologous series and discussed. Experimental standard molar volumes were correlated as a function of temperature and pressure using an empirical polynomial function. Dependences of standard molar volumes on temperature and pressure were analysed. Contributions of the methylene group to the standard molar volume were also evaluated and discussed

  15. Raman Line Imaging of Poly(ε-caprolactone)/Carbon Dioxide Solutions at High Pressures: A Combined Experimental and Computational Study for Interpreting Intermolecular Interactions and Free-Volume Effects.

    Science.gov (United States)

    Pastore Carbone, Maria Giovanna; Musto, Pellegrino; Pannico, Marianna; Braeuer, Andreas; Scherillo, Giuseppe; Mensitieri, Giuseppe; Di Maio, Ernesto

    2016-09-01

    In the present study, a Raman line-imaging setup was employed to monitor in situ the CO2 sorption at elevated pressures (from 0.62 to 7.10 MPa) in molten PCL. The method allowed the quantitative measurement of gas concentration in both the time-resolved and the space-resolved modes. The combined experimental and theoretical approach allowed a molecular level characterization of the system. The dissolved CO2 was found to occupy a volume essentially coincident with its van der Waals volume and the estimated partial molar volume of the probe did not change with pressure. Lewis acid-Lewis base interactions with the PCL carbonyls was confirmed to be the main interaction mechanism. The geometry of the supramolecular complex and the preferential interaction site were controlled more by steric than electronic effects. On the basis of the indications emerging from Raman spectroscopy, an equation of state thermodynamic model for the PCL-CO2 system, based upon a compressible lattice fluid theory endowed with specific interactions, has been tailored to account for the interaction types detected spectroscopically. The predictions of the thermodynamic model in terms of molar volume of solution have been compared with available volumetric measurements while predictions for CO2 partial molar volume have been compared with the values estimated on the basis of Raman spectroscopy.

  16. Changes of pituitary gland volume in Kennedy disease.

    Science.gov (United States)

    Pieper, C C; Teismann, I K; Konrad, C; Heindel, W L; Schiffbauer, H

    2013-12-01

    Kennedy disease is a rare X-linked neurodegenerative disorder caused by a CAG repeat expansion in the first exon of the androgen-receptor gene. Apart from neurologic signs, this mutation can cause a partial androgen insensitivity syndrome with typical alterations of gonadotropic hormones produced by the pituitary gland. The aim of the present study was therefore to evaluate the impact of Kennedy disease on pituitary gland volume under the hypothesis that endocrinologic changes caused by partial androgen insensitivity may lead to morphologic changes (ie, hypertrophy) of the pituitary gland. Pituitary gland volume was measured in sagittal sections of 3D T1-weighted 3T-MR imaging data of 8 patients with genetically proven Kennedy disease and compared with 16 healthy age-matched control subjects by use of Multitracer by a blinded, experienced radiologist. The results were analyzed by a univariant ANOVA with total brain volume as a covariant. Furthermore, correlation and linear regression analyses were performed for pituitary volume, patient age, disease duration, and CAG repeat expansion length. Intraobserver reliability was evaluated by means of the Pearson correlation coefficient. Pituitary volume was significantly larger in patients with Kennedy disease (636 [±90] mm(3)) than in healthy control subjects (534 [±91] mm(3)) (P = .041). There was no significant difference in total brain volume (P = .379). Control subjects showed a significant decrease in volume with age (r = -0.712, P = .002), whereas there was a trend to increasing gland volume in patients with Kennedy disease (r = 0.443, P = .272). Gland volume correlated with CAG repeat expansion length in patients (r = 0.630, P = .047). The correlation coefficient for intraobserver reliability was 0.94 (P pituitary volume that correlated with the CAG repeat expansion length. This could reflect hypertrophy as the result of elevated gonadotropic hormone secretion caused by the androgen receptor mutation with partial

  17. Effects of uncertainty in model predictions of individual tree volume on large area volume estimates

    Science.gov (United States)

    Ronald E. McRoberts; James A. Westfall

    2014-01-01

    Forest inventory estimates of tree volume for large areas are typically calculated by adding model predictions of volumes for individual trees. However, the uncertainty in the model predictions is generally ignored with the result that the precision of the large area volume estimates is overestimated. The primary study objective was to estimate the effects of model...

  18. Molecular theory of partial molar volume and its applications to biomolecular systems

    Directory of Open Access Journals (Sweden)

    T.Imai

    2007-09-01

    Full Text Available The paial molar volume (PMV is a thermodynamic quantity which contains important information about the solute-solvent interactions as well as the solute structure in solution.Additionally, the PMV is the most essential quantity in the analysis of the pressure effect on chemical reactions. This aicle reviews the recent developments in molecular theories of the PMV, especially the reference interaction site model (RISMtheory of molecular liquids and its three-dimensional generalization version (3D-RISM, which are combined with the Kirkwood-Buff solution theory to calculate the PMV. This aicle also introduces our recent applications of the theory to some interesting issues concerning the PMV of biomolecules. In addition, theoretical representations of the effects of intramolecular fluctuation on the PMV, which are significant for biomacromolecules, are briefly discussed.

  19. Simulation of consolidation in partially saturated soil materials

    International Nuclear Information System (INIS)

    Narasimhan, T.N.

    1982-03-01

    Partially saturated soil materials undergo consolidation, heave, collapse and failure due to changes in pore fluid pressure. The precise nature of the mechanics of such deformations is only poorly understood at present. Experimental evidence has shown that the volume change behavior of unsaturated soils cannot be adequately explained through changes in effective stress, even when a saturation dependent parameter is incorporated into the definition of effective stress. Two independent stress-state variables, involving combinations of total stress, pore air pressure and pore water pressure, are required to characterize volume changes and saturation changes in the partially saturated state. In general, two coupled conservation equations, one for the water-phase and the other for the air-phase need to be solved in order to predict the deformation behavior of unsaturated soils. If directional displacements and changes in the stress-field are required, then the conservation equations are to be integrated with an additional set of multi-dimensional force balance equations. For lack of a sufficient understanding of elastic constants such as Poisson's Ratio and Lame's constants as applied to unsaturated soils, little has been achieved so far in integrating the conservation equations and the force balance equations. For the long-term modeling of consolidation with respect to uranium mill tailings, it may be acceptable and economical to solve a single conservation equation for water, assuming that the air-phase is continuous and is at atmospheric pressure everywhere in the soil. The greatest challenge to modeling consolidation in the unsaturated zone at the presnt time is to develop enough experimental data defining the variation of void ratio and saturation with reference to the two chosen stress-state variables

  20. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  1. Effect of partial saturation of bonded neo magnet on the automotive accessory motor

    Directory of Open Access Journals (Sweden)

    Nimitkumar K. Sheth

    2017-05-01

    Full Text Available In this paper the effects of using a partially magnetized bonded neo (NdFeB magnet in an automotive accessory motor are presented. The potential reason for partial saturation of the bonded neo magnet is explained and a simple method to ensure saturation of the magnet is discussed. A magnetizing fixture design using the 2-D Finite element analysis (FEA is presented. The motor performance at various magnet saturation levels has been estimated using the 2-D FEA. Details of the thermal demagnetization test adopted by the automotive industry is also discussed and results of the motor performance for four saturation levels are detailed. These results indicate that the effect of demagnetization is more adverse in a motor with partially saturated magnets.

  2. Effect of partial saturation of bonded neo magnet on the automotive accessory motor

    Science.gov (United States)

    Sheth, Nimitkumar K.; Angara, Raghu C. S. Babu

    2017-05-01

    In this paper the effects of using a partially magnetized bonded neo (NdFeB) magnet in an automotive accessory motor are presented. The potential reason for partial saturation of the bonded neo magnet is explained and a simple method to ensure saturation of the magnet is discussed. A magnetizing fixture design using the 2-D Finite element analysis (FEA) is presented. The motor performance at various magnet saturation levels has been estimated using the 2-D FEA. Details of the thermal demagnetization test adopted by the automotive industry is also discussed and results of the motor performance for four saturation levels are detailed. These results indicate that the effect of demagnetization is more adverse in a motor with partially saturated magnets.

  3. Gravity Effects Observed In Partially Premixed Flames

    Science.gov (United States)

    Puri, Ishwar K.; Aggarwal, Suresh K.; Lock, Andrew J.; Gauguly, Ranjan; Hegde, Uday

    2003-01-01

    Partially premixed flames (PPFs) contain a rich premixed fuel air mixture in a pocket or stream, and, for complete combustion to occur, they require the transport of oxidizer from an appropriately oxidizer-rich (or fuel-lean) mixture that is present in another pocket or stream. Partial oxidation reactions occur in fuel-rich portions of the mixture and any remaining unburned fuel and/or intermediate species are consumed in the oxidizer-rich portions. Partial premixing, therefore, represents that condition when the equivalence ratio (phi) in one portion of the flowfield is greater than unity, and in another section its value is less than unity. In general, for combustion to occur efficiently, the global equivalence ratio is in the range fuel-lean to stoichiometric. These flames can be established by design by placing a fuel-rich mixture in contact with a fuel-lean mixture, but they also occur otherwise in many practical systems, which include nonpremixed lifted flames, turbulent nonpremixed combustion, spray flames, and unwanted fires. Other practical applications of PPFs are reported elsewhere. Although extensive experimental studies have been conducted on premixed and nonpremixed flames under microgravity, there is a absence of previous experimental work on burner stabilized PPFs in this regard. Previous numerical studies by our group employing a detailed numerical model showed gravity effects to be significant on the PPF structure. We report on the results of microgravity experiments conducted on two-dimensional (established on a Wolfhard-Parker slot burner) and axisymmetric flames (on a coannular burner) that were investigated in a self-contained multipurpose rig. Thermocouple and radiometer data were also used to characterize the thermal transport in the flame.

  4. Solubility comparison and partial molar volumes of 1,2-hexanediol before and after end-group modification by methyl oxalyl chloride and ethyl oxalyl monochloride in supercritical CO2

    International Nuclear Information System (INIS)

    Zhao, Lu; Yang, Hai-Jian; Cai, Zhuofu

    2013-01-01

    Highlights: ► Two new “CO 2 -philic” compounds were designed and synthesized. ► The tested solubility data were calculated and correlated with two models. ► Satisfactory agreements were obtained between the tested and calculated data. ► The partial molar volumes V ¯ 2 for three compounds were estimated. - Abstract: Bis(methoxy oxalic)-1,2-haxenediester and bis(ethoxy oxalic)-1,2-haxenediester were synthesized by modifying the end groups of 1,2-hexanediol with methyl oxalyl chloride and ethyl oxalyl monochloride. The solubilities of all three compounds in supercritical carbon dioxide were determined at different conditions of pressures (8.8 to 18.8) MPa and temperatures (313, 333, and 353) K. Then, the solubility data were correlated with the Bartle model and the Chrastil model. The average absolute relative deviation (AARD) for the Bartle model was in the range of (3.89 to 25.46)% which is within a good approximation. The Chrastil model also showed satisfactory agreement and the AARD was in the range of (3.70 to 16.92)%. Furthermore, the partial molar volumes of those compounds were estimated following the theory developed by Kumar and Johnston.

  5. Effect of dietary citric acid supplementation and partial replacement ...

    African Journals Online (AJOL)

    Beluga is one of the most important fishes in Caspian Sea. The purpose of this experiment were to evaluate the effect of soybean meal (SBM) as a fishmeal (FM) partial replacement and citric acid (CA) supplement on the calcium (Ca) and phosphorus (P) of muscle, scute and serum of Beluga diets. Three isonitrogenous and ...

  6. Partial sick leave--review of its use, effects and feasibility in the Nordic countries.

    Science.gov (United States)

    Kausto, Johanna; Miranda, Helena; Martimo, Kari-Pekka; Viikari-Juntura, Eira

    2008-08-01

    Partial sick leave and partial sickness benefits are currently available in Sweden, Norway, Denmark, and Finland. The literature was reviewed to determine their use, describe their recipients, find evidence of their effects, and explore attitudes towards and experiences with their use. Eight databases were searched. National sickness absence statistics and other relevant sources were also reviewed. Of the sickness benefits, partial benefits accounted for approximately one-fifth in Norway, less than 10% in Denmark, and over a third in Sweden. In Finland, partial sick leave was seldom used during the first year (2007) of benefit availability. Few peer-reviewed studies on its effects were identified, and scientific evidence was scarce. Its acceptance was good in all four countries. Most of the recipients were women and over 45 years of age. Studies of its feasibility seem congruent in reporting hindrances due to inflexible work arrangements and poor collaboration between actors. More research and more rigorous study designs are needed to determine whether partial sick leave is feasible and beneficial in keeping those with reduced work ability in worklife.

  7. Essays on partial retirement

    NARCIS (Netherlands)

    Kantarci, T.

    2012-01-01

    The five essays in this dissertation address a range of topics in the micro-economic literature on partial retirement. The focus is on the labor market behavior of older age groups. The essays examine the economic and non-economic determinants of partial retirement behavior, the effect of partial

  8. Association between partial-volume corrected SUVmax and Oncotype DX recurrence score in early-stage, ER-positive/HER2-negative invasive breast cancer.

    Science.gov (United States)

    Lee, Su Hyun; Ha, Seunggyun; An, Hyun Joon; Lee, Jae Sung; Han, Wonshik; Im, Seock-Ah; Ryu, Han Suk; Kim, Won Hwa; Chang, Jung Min; Cho, Nariya; Moon, Woo Kyung; Cheon, Gi Jeong

    2016-08-01

    Oncotype DX, a 21-gene expression assay, provides a recurrence score (RS) which predicts prognosis and the benefit from adjuvant chemotherapy in patients with early-stage, estrogen receptor-positive (ER-positive), and human epidermal growth factor receptor 2-negative (HER2-negative) invasive breast cancer. However, Oncotype DX tests are expensive and not readily available in all institutions. The purpose of this study was to investigate whether metabolic parameters on (18)F-FDG PET/CT are associated with the Oncotype DX RS and whether (18)F-FDG PET/CT can be used to predict the Oncotype DX RS. The study group comprised 38 women with stage I/II, ER-positive/HER2-negative invasive breast cancer who underwent pretreatment (18)F-FDG PET/CT and Oncotype DX testing. On PET/CT, maximum (SUVmax) and average standardized uptake values, metabolic tumor volume, and total lesion glycolysis were measured. Partial volume-corrected SUVmax (PVC-SUVmax) determined using the recovery coefficient method was also evaluated. Oncotype DX RS (0 - 100) was categorized as low (negative breast cancer.

  9. Generalized effective mode volume for leaky optical cavities

    DEFF Research Database (Denmark)

    Kristensen, Philip Trøst; Van Vlack, C.; Hughes, S.

    2012-01-01

    We show explicitly how the commonly adopted prescription for calculating effective mode volumes is wrong and leads to uncontrolled errors. Instead, we introduce a generalized mode volume that can be easily evaluated based on the mode calculation methods typically applied in the literature, and wh......, and which allows one to compute the Purcell effect and other interesting optical phenomena in a rigorous and unambiguous way....

  10. Volumetric gain of the human pancreas after left partial pancreatic resection: A CT-scan based retrospective study.

    Science.gov (United States)

    Phillip, Veit; Zahel, Tina; Danninger, Assiye; Erkan, Mert; Dobritz, Martin; Steiner, Jörg M; Kleeff, Jörg; Schmid, Roland M; Algül, Hana

    2015-01-01

    Regeneration of the pancreas has been well characterized in animal models. However, there are conflicting data on the regenerative capacity of the human pancreas. The aim of the present study was to assess the regenerative capacity of the human pancreas. In a retrospective study, data from patients undergoing left partial pancreatic resection at a single center were eligible for inclusion (n = 185). Volumetry was performed based on 5 mm CT-scans acquired through a 256-slice CT-scanner using a semi-automated software. Data from 24 patients (15 males/9 females) were included. Mean ± SD age was 68 ± 11 years (range, 40-85 years). Median time between surgery and the 1st postoperative CT was 9 days (range, 0-27 days; IQR, 7-13), 55 days (range, 21-141 days; IQR, 34-105) until the 2nd CT, and 191 days (range, 62-1902; IQR, 156-347) until the 3rd CT. The pancreatic volumes differed significantly between the first and the second postoperative CT scans (median volume 25.6 mL and 30.6 mL, respectively; p = 0.008) and had significantly increased further by the 3rd CT scan (median volume 37.9 mL; p = 0.001 for comparison with 1st CT scan and p = 0.003 for comparison with 2nd CT scan). The human pancreas shows a measurable and considerable potential of volumetric gain after partial resection. Multidetector-CT based semi-automated volume analysis is a feasible method for follow-up of the volume of the remaining pancreatic parenchyma after partial pancreatectomy. Effects on exocrine and endocrine pancreatic function have to be evaluated in a prospective manner. Copyright © 2015 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  11. Liquidity Effects on the Simultaneity of Trading Volume and Order Imbalance

    Directory of Open Access Journals (Sweden)

    Erman Denny Arfianto

    2016-10-01

    Full Text Available The purpose of this research is to analyze the simultaneity between trading volume and order imbalance, the influence of past performance, market risk, market capitalization, tick size to the trading volume and the influence of tick size, depth and bid-ask spread to the order imbalance of companies that were listed on LQ 45 index. The samples in this research were selected by using the purposive sampling method with some selected criteria. Fifty-five companies listed on 2014’s LQ 45 index were chosen as the sample. The results showed that the trading volume is simultaneously related to the order imbalance; past performance, market risk, and market capitalization have the positive and significant effect to the trading volume; tick size has the negative and significant effect to the trading volume; the order imbalance has the negative and insignificant effect to the trading volume; tick size, depth, bid-ask spread, and trading volume have no significant effect to the order imbalance.

  12. Simulation-based partial volume correction for dopaminergic PET imaging. Impact of segmentation accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Rong, Ye; Winz, Oliver H. [University Hospital Aachen (Germany). Dept. of Nuclear Medicine; Vernaleken, Ingo [University Hospital Aachen (Germany). Dept. of Psychiatry, Psychotherapy and Psychosomatics; Goedicke, Andreas [University Hospital Aachen (Germany). Dept. of Nuclear Medicine; High Tech Campus, Philips Research Lab., Eindhoven (Netherlands); Mottaghy, Felix M. [University Hospital Aachen (Germany). Dept. of Nuclear Medicine; Maastricht University Medical Center (Netherlands). Dept. of Nuclear Medicine; Rota Kops, Elena [Forschungszentrum Juelich (Germany). Inst. of Neuroscience and Medicine-4

    2015-07-01

    Partial volume correction (PVC) is an essential step for quantitative positron emission tomography (PET). In the present study, PVELab, a freely available software, is evaluated for PVC in {sup 18}F-FDOPA brain-PET, with a special focus on the accuracy degradation introduced by various MR-based segmentation approaches. Methods Four PVC algorithms (M-PVC; MG-PVC; mMG-PVC; and R-PVC) were analyzed on simulated {sup 18}F-FDOPA brain-PET images. MR image segmentation was carried out using FSL (FMRIB Software Library) and SPM (Statistical Parametric Mapping) packages, including additional adaptation for subcortical regions (SPM{sub L}). Different PVC and segmentation combinations were compared with respect to deviations in regional activity values and time-activity curves (TACs) of the occipital cortex (OCC), caudate nucleus (CN), and putamen (PUT). Additionally, the PVC impact on the determination of the influx constant (K{sub i}) was assessed. Results Main differences between tissue-maps returned by three segmentation algorithms were found in the subcortical region, especially at PUT. Average misclassification errors in combination with volume reduction was found to be lowest for SPM{sub L} (PUT < 30%) and highest for FSL (PUT > 70%). Accurate recovery of activity data at OCC is achieved by M-PVC (apparent recovery coefficient varies between 0.99 and 1.10). The other three evaluated PVC algorithms have demonstrated to be more suitable for subcortical regions with MG-PVC and mMG-PVC being less prone to the largest tissue misclassification error simulated in this study. Except for M-PVC, quantification accuracy of K{sub i} for CN and PUT was clearly improved by PVC. Conclusions The regional activity value of PUT was appreciably overcorrected by most of the PVC approaches employing FSL or SPM segmentation, revealing the importance of accurate MR image segmentation for the presented PVC framework. The selection of a PVC approach should be adapted to the anatomical

  13. Handbook of differential equations stationary partial differential equations

    CERN Document Server

    Chipot, Michel

    2006-01-01

    This handbook is volume III in a series devoted to stationary partial differential quations. Similarly as volumes I and II, it is a collection of self contained state-of-the-art surveys written by well known experts in the field. The topics covered by this handbook include singular and higher order equations, problems near critically, problems with anisotropic nonlinearities, dam problem, T-convergence and Schauder-type estimates. These surveys will be useful for both beginners and experts and speed up the progress of corresponding (rapidly developing and fascinating) areas of mathematics. Ke

  14. Oxygen partial pressure effects on the magnetron sputtered WO3 films

    International Nuclear Information System (INIS)

    Muğlu, G Merhan; Gür, E

    2016-01-01

    Electrochromism is changing color of a substance in response to the applied an external electric field and the phenomenon is reversible. WO 3 is very attractive material due to its electrochromic properties as well as it is also attractive for many different applications such as gas sensors, phosphorous screen, textile, glass industry. In this study, it is aimed to provide optimization of the optical and structural characteristics of WO 3 by changing the growth parameters mainly the oxygen partial pressure. The partial pressure of oxygen was changed with increments of 0.7 mTorr. For the analysis, X-ray Diffraction (XRD), absorption, Raman spectroscopy measurements were used. When O 2 gas increased, peaks belong to the WO 3 was observed in XRD patterns at the 2 theta angles of 23.0, 11.0, 23.5 and 28.5 angles corresponding to the (002), (020) and (220) planes, respectively. This shows that there is a significant effect of increasing O 2 partial pressure in the formation of WO 3 films. The bandgap energy of the WO 3 thin films are found to be around 3.0 eV. Raman measurements showed vibrational modes of W-O-W stretching and bending modes which shows small shifts depending on the partial pressures of the O 2 . Obtained results indicated that better crystal structure is obtained with higher O 2 gas partial pressure. (paper)

  15. Hamiltonian partial differential equations and applications

    CERN Document Server

    Nicholls, David; Sulem, Catherine

    2015-01-01

    This book is a unique selection of work by world-class experts exploring the latest developments in Hamiltonian partial differential equations and their applications. Topics covered within are representative of the field’s wide scope, including KAM and normal form theories, perturbation and variational methods, integrable systems, stability of nonlinear solutions as well as applications to cosmology, fluid mechanics and water waves. The volume contains both surveys and original research papers and gives a concise overview of the above topics, with results ranging from mathematical modeling to rigorous analysis and numerical simulation. It will be of particular interest to graduate students as well as researchers in mathematics and physics, who wish to learn more about the powerful and elegant analytical techniques for Hamiltonian partial differential equations.

  16. Influence of Co-57 and CT Transmission Measurements on the Quantification Accuracy and Partial Volume Effect of a Small Animal PET Scanner.

    Science.gov (United States)

    Mannheim, Julia G; Schmid, Andreas M; Pichler, Bernd J

    2017-12-01

    Non-invasive in vivo positron emission tomography (PET) provides high detection sensitivity in the nano- to picomolar range and in addition to other advantages, the possibility to absolutely quantify the acquired data. The present study focuses on the comparison of transmission data acquired with an X-ray computed tomography (CT) scanner or a Co-57 source for the Inveon small animal PET scanner (Siemens Healthcare, Knoxville, TN, USA), as well as determines their influences on the quantification accuracy and partial volume effect (PVE). A special focus included the impact of the performed calibration on the quantification accuracy. Phantom measurements were carried out to determine the quantification accuracy, the influence of the object size on the quantification, and the PVE for different sphere sizes, along the field of view and for different contrast ratios. An influence of the emission activity on the Co-57 transmission measurements was discovered (deviations up to 24.06 % measured to true activity), whereas no influence of the emission activity on the CT attenuation correction was identified (deviations influenced by the applied calibration factor and by the object size. The PVE demonstrated a dependency on the sphere size, the position within the field of view, the reconstruction and correction algorithms and the count statistics. Depending on the reconstruction algorithm, only ∼30-40 % of the true activity within a small sphere could be resolved. The iterative 3D reconstruction algorithms uncovered substantially increased recovery values compared to the analytical and 2D iterative reconstruction algorithms (up to 70.46 % and 80.82 % recovery for the smallest and largest sphere using iterative 3D reconstruction algorithms). The transmission measurement (CT or Co-57 source) to correct for attenuation did not severely influence the PVE. The analysis of the quantification accuracy and the PVE revealed an influence of the object size, the reconstruction

  17. The effect of blood volume loss on cardiovascular response to lower body negative pressure using a mathematical model

    Science.gov (United States)

    Karam, E. H.; Srinivasan, R. S.; Charles, J. B.; Fortney, S. M.

    1994-01-01

    Different mathematical models of varying complexity have been proposed in recent years to study the cardiovascular (CV) system. However, only a few of them specifically address the response to lower body negative pressure (LBNP), a stress that can be applied in weightlessness to predict changes in orthostatic tolerance. Also, the simulated results produced by these models agree only partially with experimental observations. In contrast, the model proposed by Melchior et al., and modified by Karam et al. is a simple representation of the CV system capable of accurately reproducing observed LBNP responses up to presyncopal levels. There are significant changes in LBNP response due to a loss of blood volume and other alterations that occur in weightlessness and related one-g conditions such as bedrest. A few days of bedrest can cause up to 15% blood volume loss (BVL), with consequent decreases in both stroke volume and cardiac output, and increases in heart rate, mean arterial pressure, and total peripheral resistance. These changes are more pronounced at higher levels of LBNP. This paper presents the results of a simulation study using our CV model to examine the effect of BVL on LBNP response.

  18. Improving the developability profile of pyrrolidine progesterone receptor partial agonists

    Energy Technology Data Exchange (ETDEWEB)

    Kallander, Lara S.; Washburn, David G.; Hoang, Tram H.; Frazee, James S.; Stoy, Patrick; Johnson, Latisha; Lu, Qing; Hammond, Marlys; Barton, Linda S.; Patterson, Jaclyn R.; Azzarano, Leonard M.; Nagilla, Rakesh; Madauss, Kevin P.; Williams, Shawn P.; Stewart, Eugene L.; Duraiswami, Chaya; Grygielko, Eugene T.; Xu, Xiaoping; Laping, Nicholas J.; Bray, Jeffrey D.; Thompson, Scott K. (GSKPA)

    2010-09-17

    The previously reported pyrrolidine class of progesterone receptor partial agonists demonstrated excellent potency but suffered from serious liabilities including hERG blockade and high volume of distribution in the rat. The basic pyrrolidine amine was intentionally converted to a sulfonamide, carbamate, or amide to address these liabilities. The evaluation of the degree of partial agonism for these non-basic pyrrolidine derivatives and demonstration of their efficacy in an in vivo model of endometriosis is disclosed herein.

  19. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    Science.gov (United States)

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  20. Effect of large volume paracentesis on plasma volume--a cause of hypovolemia

    International Nuclear Information System (INIS)

    Kao, H.W.; Rakov, N.E.; Savage, E.; Reynolds, T.B.

    1985-01-01

    Large volume paracentesis, while effectively relieving symptoms in patients with tense ascites, has been generally avoided due to reports of complications attributed to an acute reduction in intravascular volume. Measurements of plasma volume in these subjects have been by indirect methods and have not uniformly confirmed hypovolemia. We have prospectively evaluated 18 patients (20 paracenteses) with tense ascites and peripheral edema due to chronic liver disease undergoing 5 liter paracentesis for relief of symptoms. Plasma volume pre- and postparacentesis was assessed by a 125 I-labeled human serum albumin dilution technique as well as by the change in hematocrit and postural blood pressure difference. No significant change in serum sodium, urea nitrogen, hematocrit or postural systolic blood pressure difference was noted at 24 or 48 hr after paracentesis. Serum creatinine at 24 hr after paracentesis was unchanged but a small but statistically significant increase in serum creatinine was noted at 48 hr postparacentesis. Plasma volume changed -2.7% (n = 6, not statistically significant) during the first 24 hr and -2.8% (n = 12, not statistically significant) during the 0- to 48-hr period. No complications from paracentesis were noted. These results suggest that 5 liter paracentesis for relief of symptoms is safe in patients with tense ascites and peripheral edema from chronic liver disease

  1. Common Vocal Effects and Partial Glottal Vibration in Professional Nonclassical Singers.

    Science.gov (United States)

    Caffier, Philipp P; Ibrahim Nasr, Ahmed; Ropero Rendon, Maria Del Mar; Wienhausen, Sascha; Forbes, Eleanor; Seidner, Wolfram; Nawka, Tadeus

    2018-05-01

    To multidimensionally investigate common vocal effects in experienced professional nonclassical singers, to examine their mechanism of production and reproducibility, to demonstrate the existence of partial glottal vibration, and to assess the potential of damage to the voice from nonclassical singing. Individual cohort study. Ten male singers aged between 25 and 46 years (34 ± 7 years [mean ± SD]) with different stylistic backgrounds were recruited (five pop/rock/metal, five musical theater). Participants repeatedly presented the usual nonclassical vocal effects and techniques in their repertoire. All performances were documented and analyzed using established instruments (eg, auditory-perceptual assessment, videolaryngostroboscopy, electroglottography, voice function diagnostics). The vocal apparatus of all singers was healthy and capable of high performance. Typical nonclassical vocal effects were breathy voice, creaky voice, vocal fry, grunting, distortion, rattle, belt, and twang. All effects could be easily differentiated from each other. They were intraindividually consistently repeatable and also interindividually produced in a similar manner. A special feature in one singer was the first evidence of partial glottal vibration when belting in the high register. The unintended transition to this reduced voice quality was accompanied by physical fatigue and inflexible respiratory support. The long-lasting use of the investigated nonclassical vocal effects had no negative impact on trained singers. The possibility of long-term damage depends on the individual constitution, specific use, duration, and extent of the hyperfunction. The incidence of partial glottal vibration and its consequences require continuing research to learn more about efficient and healthy vocal function in nonclassical singing. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  2. Optimal partial-arcs in VMAT treatment planning

    International Nuclear Information System (INIS)

    Wala, Jeremiah; Salari, Ehsan; Chen Wei; Craft, David

    2012-01-01

    We present a method for improving the delivery efficiency of VMAT by extending the recently published VMAT treatment planning algorithm vmerge to automatically generate optimal partial-arc plans. A high-quality initial plan is created by solving a convex multicriteria optimization problem using 180 equi-spaced beams. This initial plan is used to form a set of dose constraints, and a set of partial-arc plans is created by searching the space of all possible partial-arc plans that satisfy these constraints. For each partial-arc, an iterative fluence map merging and sequencing algorithm (vmerge) is used to improve the delivery efficiency. Merging continues as long as the dose quality is maintained above a user-defined threshold. The final plan is selected as the partial-arc with the lowest treatment time. The complete algorithm is called pmerge. Partial-arc plans are created using pmerge for a lung, liver and prostate case, with final treatment times of 127, 245 and 147 s. Treatment times using full arcs with vmerge are 211, 357 and 178 s. The mean doses to the critical structures for the vmerge and pmerge plans are kept within 5% of those in the initial plan, and the target volume covered by the prescription isodose is maintained above 98% for the pmerge and vmerge plans. Additionally, we find that the angular distribution of fluence in the initial plans is predictive of the start and end angles of the optimal partial-arc. We conclude that VMAT delivery efficiency can be improved by employing partial-arcs without compromising dose quality, and that partial-arcs are most applicable to cases with non-centralized targets. (paper)

  3. [Effect of SO2 volume fraction in flue gas on the adsorption behaviors adsorbed by ZL50 activated carbon and kinetic analysis].

    Science.gov (United States)

    Gao, Ji-xian; Wang, Tie-feng; Wang, Jin-fu

    2010-05-01

    The influence of SO2 dynamic adsorption behaviors using ZL50 activated carbon for flue gas desulphurization and denitrification under different SO2 volume fraction was investigated experimentally, and the kinetic analysis was conducted by kinetic models. With the increase of SO2 volume fraction in flue gas, the SO2 removal ratio and the activity ratio of ZL50 activated carbon decreased, respectively, and SO2 adsorption rate and capacity increased correspondingly. The calculated results indicate that Bangham model has the best prediction effect, the chemisorption processes of SO2 was significantly affected by catalytic oxidative reaction. The adsorption rate constant of Lagergren's pseudo first order model increased with the increase of inlet SO, volume fraction, which indicated that catalytic oxidative reaction of SO2 adsorbed by ZL50 activated carbon may be the rate controlling step in earlier adsorption stage. The Lagergren's and Bangham's initial adsorption rate were deduced and defined, respectively. The Ho's and Elovich's initial adsorption rate were also deduced in this paper. The Bangham's initial adsorption rate values were defined in good agreement with those of experiments. The defined Bangham's adsorptive reaction kinetic model can describe the SO2 dynamic adsorption rate well. The studied results indicated that the SO2 partial order of initial reaction rate was one or adjacent to one, while the O2 and water vapor partial order of initial reaction rate were constants ranging from 0.15-0.20 and 0.45-0.50, respectively.

  4. Partially massless higher-spin theory II: one-loop effective actions

    Energy Technology Data Exchange (ETDEWEB)

    Brust, Christopher [Perimeter Institute for Theoretical Physics,31 Caroline St. N, Waterloo, Ontario, N2L 2Y5 (Canada); Hinterbichler, Kurt [CERCA, Department of Physics, Case Western Reserve University,10900 Euclid Ave, Cleveland, OH, 44106 (United States)

    2017-01-30

    We continue our study of a generalization of the D-dimensional linearized Vasiliev higher-spin equations to include a tower of partially massless (PM) fields. We compute one-loop effective actions by evaluating zeta functions for both the “minimal” and “non-minimal” parity-even versions of the theory. Specifically, we compute the log-divergent part of the effective action in odd-dimensional Euclidean AdS spaces for D=7 through 19 (dual to the a-type conformal anomaly of the dual boundary theory), and the finite part of the effective action in even-dimensional Euclidean AdS spaces for D=4 through 8 (dual to the free energy on a sphere of the dual boundary theory). We pay special attention to the case D=4, where module mixings occur in the dual field theory and subtlety arises in the one-loop computation. The results provide evidence that the theory is UV complete and one-loop exact, and we conjecture and provide evidence for a map between the inverse Newton’s constant of the partially massless higher-spin theory and the number of colors in the dual CFT.

  5. Partially massless higher-spin theory II: one-loop effective actions

    International Nuclear Information System (INIS)

    Brust, Christopher; Hinterbichler, Kurt

    2017-01-01

    We continue our study of a generalization of the D-dimensional linearized Vasiliev higher-spin equations to include a tower of partially massless (PM) fields. We compute one-loop effective actions by evaluating zeta functions for both the “minimal” and “non-minimal” parity-even versions of the theory. Specifically, we compute the log-divergent part of the effective action in odd-dimensional Euclidean AdS spaces for D=7 through 19 (dual to the a-type conformal anomaly of the dual boundary theory), and the finite part of the effective action in even-dimensional Euclidean AdS spaces for D=4 through 8 (dual to the free energy on a sphere of the dual boundary theory). We pay special attention to the case D=4, where module mixings occur in the dual field theory and subtlety arises in the one-loop computation. The results provide evidence that the theory is UV complete and one-loop exact, and we conjecture and provide evidence for a map between the inverse Newton’s constant of the partially massless higher-spin theory and the number of colors in the dual CFT.

  6. The effect of lifelong bilingualism on regional grey and white matter volume.

    Science.gov (United States)

    Olsen, Rosanna K; Pangelinan, Melissa M; Bogulski, Cari; Chakravarty, M Mallar; Luk, Gigi; Grady, Cheryl L; Bialystok, Ellen

    2015-07-01

    Lifelong bilingualism is associated with the delayed diagnosis of dementia, suggesting bilingual experience is relevant to brain health in aging. While the effects of bilingualism on cognitive functions across the lifespan are well documented, less is known about the neural substrates underlying differential behaviour. It is clear that bilingualism affects brain regions that mediate language abilities and that these regions are at least partially overlapping with those that exhibit age-related decline. Moreover, the behavioural advantages observed in bilingualism are generally found in executive function performance, suggesting that the frontal lobes may also be sensitive to bilingualism, which exhibit volume reductions with age. The current study investigated structural differences in the brain of lifelong bilingual older adults (n=14, mean age=70.4) compared with older monolinguals (n=14, mean age=70.6). We employed two analytic approaches: 1) we examined global differences in grey and white matter volumes; and, 2) we examined local differences in volume and cortical thickness of specific regions of interest previously implicated in bilingual/monolingual comparisons (temporal pole) or in aging (entorhinal cortex and hippocampus). We expected bilinguals would exhibit greater volume of the frontal lobe and temporal lobe (grey and white matter), given the importance of these regions in executive and language functions, respectively. We further hypothesized that regions in the medial temporal lobe, which demonstrate early changes in aging and exhibit neural pathology in dementia, would be more preserved in the bilingual group. As predicted, bilinguals exhibit greater frontal lobe white matter compared with monolinguals. Moreover, increasing age was related to decreasing temporal pole cortical thickness in the monolingual group, but no such relationship was observed for bilinguals. Finally, Stroop task performance was positively correlated with frontal lobe white

  7. Two-fold sustainability – Adobe with sawdust as partial sand replacement

    Science.gov (United States)

    Jokhio, Gul A.; Syed Mohsin, Sharifah M.; Gul, Yasmeen

    2018-04-01

    Adobe is a material that is economic, environment friendly, and provides better indoor air quality. The material required for the preparation of adobe include clay, sand, and sometimes straw or other organic materials. These materials do not require industrial processing or transportation, however, sand mining has been recently posing a threat to the environment. Therefore, to enhance the existing sustainability of adobe, sand can be partially or fully replaced by other waste materials. This approach will not only solve the problem of excessive sand mining, it will also address the issue of waste management. Sawdust is one such waste material that can be used to partially replace sand in Adobe. This paper presents the results of compressive and flexural test carried out on Adobe samples with partial sand replacement by sawdust. The results show that about 4% sand replacement by volume produces higher compressive strength, whereas the flexural strength reduces with the use of sawdust. However, since flexural strength is not a critical property for adobe, it is concluded that replacing sand with sawdust by about 4% of volume will be beneficial.

  8. Effects of partial crystallinity and quenched-in defects on corrosion of ...

    Indian Academy of Sciences (India)

    Unknown

    Rapid solidification by planar flow casting has been found to have introduced deficiencies, viz. ... alloy. In order to investigate the effects of these deficiencies on the corrosion of rapidly ... Partial crystallinity (Dutta et al 1995; Savalia et al 1996),.

  9. Effect of partial replacement of growers mash with gliricidia sepium ...

    African Journals Online (AJOL)

    This study was designed to determine the effect of partial replacement of growers mash with Gliricidia sepium leaf meal (GLM) on the growth of chinchilla rabbits and to determine its implication for extension advisory services. In this study, 10 eight weeks old Chinchilla rabbits were used. They were randomly allotted to three ...

  10. Dynamics of partial differential equations

    CERN Document Server

    Wayne, C Eugene

    2015-01-01

    This book contains two review articles on the dynamics of partial differential equations that deal with closely related topics but can be read independently. Wayne reviews recent results on the global dynamics of the two-dimensional Navier-Stokes equations. This system exhibits stable vortex solutions: the topic of Wayne's contribution is how solutions that start from arbitrary initial conditions evolve towards stable vortices. Weinstein considers the dynamics of localized states in nonlinear Schrodinger and Gross-Pitaevskii equations that describe many optical and quantum systems. In this contribution, Weinstein reviews recent bifurcations results of solitary waves, their linear and nonlinear stability properties, and results about radiation damping where waves lose energy through radiation.   The articles, written independently, are combined into one volume to showcase the tools of dynamical systems theory at work in explaining qualitative phenomena associated with two classes of partial differential equ...

  11. Partial Deconvolution with Inaccurate Blur Kernel.

    Science.gov (United States)

    Ren, Dongwei; Zuo, Wangmeng; Zhang, David; Xu, Jun; Zhang, Lei

    2017-10-17

    Most non-blind deconvolution methods are developed under the error-free kernel assumption, and are not robust to inaccurate blur kernel. Unfortunately, despite the great progress in blind deconvolution, estimation error remains inevitable during blur kernel estimation. Consequently, severe artifacts such as ringing effects and distortions are likely to be introduced in the non-blind deconvolution stage. In this paper, we tackle this issue by suggesting: (i) a partial map in the Fourier domain for modeling kernel estimation error, and (ii) a partial deconvolution model for robust deblurring with inaccurate blur kernel. The partial map is constructed by detecting the reliable Fourier entries of estimated blur kernel. And partial deconvolution is applied to wavelet-based and learning-based models to suppress the adverse effect of kernel estimation error. Furthermore, an E-M algorithm is developed for estimating the partial map and recovering the latent sharp image alternatively. Experimental results show that our partial deconvolution model is effective in relieving artifacts caused by inaccurate blur kernel, and can achieve favorable deblurring quality on synthetic and real blurry images.Most non-blind deconvolution methods are developed under the error-free kernel assumption, and are not robust to inaccurate blur kernel. Unfortunately, despite the great progress in blind deconvolution, estimation error remains inevitable during blur kernel estimation. Consequently, severe artifacts such as ringing effects and distortions are likely to be introduced in the non-blind deconvolution stage. In this paper, we tackle this issue by suggesting: (i) a partial map in the Fourier domain for modeling kernel estimation error, and (ii) a partial deconvolution model for robust deblurring with inaccurate blur kernel. The partial map is constructed by detecting the reliable Fourier entries of estimated blur kernel. And partial deconvolution is applied to wavelet-based and learning

  12. The low-energy effective theory of QCD at small quark masses in a finite volume

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, Christoph

    2010-01-15

    At low energies the theory of quantum chromodynamics (QCD) can be described effectively in terms of the lightest particles of the theory, the pions. This approximation is valid for temperatures well below the mass difference of the pions to the next heavier particles. We study the low-energy effective theory at very small quark masses in a finite volume V. The corresponding perturbative expansion in 1/{radical}(V) is called {epsilon} expansion. At each order of this expansion a finite number of low-energy constants completely determine the effective theory. These low-energy constants are of great phenomenological importance. In the leading order of the {epsilon} expansion, called {epsilon} regime, the theory becomes zero-dimensional and is therefore described by random matrix theory (RMT). The dimensionless quantities of RMT are mapped to dimensionful quantities of the low-energy effective theory using the leading-order lowenergy constants {sigma} and F. In this way {sigma} and F can be obtained from lattice QCD simulations in the '' regime by a fit to RMT predictions. For typical volumes of state-of-the-art lattice QCD simulations, finite-volume corrections to the RMT prediction cannot be neglected. These corrections can be calculated in higher orders of the {epsilon} expansion. We calculate the finite-volume corrections to {sigma} and F at next-to-next-to-leading order in the {epsilon} expansion. We also discuss non-universal modifications of the theory due to the finite volume. These results are then applied to lattice QCD simulations, and we extract {sigma} and F from eigenvalue correlation functions of the Dirac operator. As a side result, we provide a proof of equivalence between the parametrization of the partially quenched low-energy effective theory without singlet particle and that of the super-Riemannian manifold used earlier in the literature. Furthermore, we calculate a special version of the massless sunset diagram at finite volume without

  13. The effect of unilateral partial edentulism to muscle thickness

    International Nuclear Information System (INIS)

    Koca-Ceylan, Golzem; Guler, Ahmet U.; Taskay-Yelmir, Nergiz; Lutfi, Incesu; Aksoz, Tolga

    2003-01-01

    Teeth and muscle play a very important role for occlusal equilibrium and function.when tooth loss begins ,it may also effect the function of muscle tissues. The thickness of masseter and anterior temporalis muscles were measured bilaterally in 30 healthy fully dentate adults and in 30 unilateral edentulous patients by using ultrasonographic imaging. All scans were carried out by the same radiologist to eliminate the inter-observer difference, using a real time scanner (Toshiba SSA -270A,Japan). A 7.5 MHz linear transducer was used. The effect of age, sex, duration of partial edentulism, unilateral chewing habits of the individuals to the muscle thickness were also evaluated. In all subjects,facial proportion index was also determined. Main purpose of this study was to compare and establish the differences of muscle thickness between dentate and edentulous side in unilateral partial edentulous patients with ultrasonography and to test whether the variation in the thickness of the muscle is related to the variation in the facial and morphology. Ultrasonography revealed a large variation in the thickness of the masseter and temporolis muscles in experimental and controlled groups ,both relaxed and contracted conditions.The thickness of muscles in females was less in both conditions.In experimental group, a high negative correlation was found between the thickness of the masseter muscle and Facial Proportion Index ( FPI) in the females ,however, the statistical analysis showed no significant difference in the males. Also a high negative correlation was found in female control group. There was no statistically significant relationship between unilateral chewing habits and muscle thickness .In this study the duration of partial edentulism did not affect the thickness of the muscle.Further research is required to study muscular atrophy for comparison with total edentulism. (author)

  14. Excluded Volume Effects in Gene Stretching

    OpenAIRE

    Lam, Pui-Man

    2002-01-01

    We investigate the effects excluded volume on the stretching of a single DNA in solution. We find that for small force F, the extension h is not linear in F but proportion to F^{\\chi}, with \\chi=(1-\

  15. The Investigation on Flexural Toughness of Partially Steel Fiber Reinforced Concrete Immersed by Simulated Sea-Water

    Directory of Open Access Journals (Sweden)

    Feng GAO

    2017-11-01

    Full Text Available In order to investigate the corrosive resistance of partially steel fiber reinforced concrete (PSFRC, the flexural toughness experiment of nine specimens subjected to corrosion by alternating wet and dry cycles in a simulated marine environment were conducted, which aims at investigating the effect of corrosion time, steel fiber volume fraction and SFRC thickness on PSFRC toughness. The experimental results showed that both the mechanical and ductile characteristics of PSFRC got worse due to corrosion even if increasing the steel fiber volume. Additionally, the effect of steel fiber content on the toughness and ultimate load are greater than PSFRC thickness (t. The increase of 56.6% and 171% could be obtained in the mean ultimate load and I10 if the increase of steel fiber volume is from 0.5 % to 2.0%, respectively. This paper could offer a reference to the application of PSFRC in sea-water environment.DOI: http://dx.doi.org/10.5755/j01.ms.23.4.17049

  16. Relationship between partial and average atomic volumes of components in Au-Ni alloys%Au-Ni合金中组元的平均原子体积和偏摩尔体积的关系

    Institute of Scientific and Technical Information of China (English)

    谢佑卿

    2011-01-01

    在系统合金科学框架中建立有关无序合金的平均摩尔性质(体积和势能)的函数.通过对这些函数进行推导,可以得到平均摩尔体积函数、偏摩尔体积函数及派生出与成分相关的函数.在组元的偏摩尔性质和平均摩尔性质之间的普适方程、差分方程、在偏摩尔性质和平均摩尔性质之间不同参数的约束方程和普适的Gibbs-Duhem公式.可以证明从合金平均摩尔性质的不同函数计算的偏摩尔性质是相等的,但总体来说偏摩尔性质不等于给定组元的平均摩尔性质,即偏摩尔性质不能代表相应组元的摩尔性质.通过计算Au-Ni系中组元的偏摩尔体积和平均原子体积以及合金的平均原子体积,证明所建立的公式和函数的正确性.%In the framework of systematic science of alloys,the average molar property (volume and potential energy) functions of disordered alloys were established.From these functions,the average molar property functions,partial molar property functions,derivative functions with respect to composition,general equation of relationship between partial and average molar properties of components,difference equation and constraining equation of different values between partial and average molar properties,as well as general Gibbs-Duhem formula were derived.It was proved that the partial molar properties calculated from various combinative functions of average molar properties of alloys are equal,but in general,the partial molar properties are not equal to the average molar properties of a given component.This means that the partial molar properties cannot represent the corresponding properties of the component.All the equations and functions established in this work were proved to be correct by calculating the results of partial and average atomic volumes of components as well as average atomic volumes of alloys in the Au-Ni system.

  17. Volume conduction effects on wavelet cross-bicoherence analysis

    International Nuclear Information System (INIS)

    Memon, I.A.; Channa, C.

    2013-01-01

    Cross-bicoherence analysis is one of the important nonlinear signal processing tools which is used to measure quadratic phase coupling between frequencies of two different time series. It is frequently used in the diagnosis of various cognitive and neurological disorders in EEG (Electroencephalography) analysis. Volume conduction effects of various uncorrelated sources present in the brain can produce biased estimates into the estimated values of cross-bicoherence function. Previous studies have discussed volume conduction effects on coherence function which is used to measure linear relationship between EEG signals in terms of their phase and amplitude. However, volume conduction effect on cross-bicoherence analysis which is quite a different technique has not been investigated up to now to the best of our knowledge. This study is divided into two major parts, the first part deals with the investigation of VCUS (Volume Conduction effects due to Uncorrelated Sources) characteristics on EEG-cross-bicoherence analysis. The simulated EEG data due to uncorrelated sources present in the brain was used in this part of study. The next part of study is based upon investigating the effects of VCUS on the statistical analysis of results of EEG-based cross-bicoherence analysis. The study provides an important clinical application because most of studies based on EEG cross-bicoherence analysis have avoided the issue of VCUS. The cross-bicoherence analysis was performed by detecting the change in MSCB (Magnitude Square Cross-Bicoherence Function) between EEG activities of change detection and no-change detection trials. The real EEG signals were used. (author)

  18. Comparison of effectiveness of electrocautery and phenol application in partial matricectomy after partial nail extraction in the treatment of ingrown nails.

    Science.gov (United States)

    Misiak, Piotr; Terlecki, Artur; Rzepkowska-Misiak, Beata; Wcisło, Szymon; Brocki, Marian

    2014-02-01

    Ingrowing nail also known as onychocryptosis is a common health problem. This disease mostly affects young people, often carrying a considerable amount of socio-economic implications. It's foot problem that usually manifests as inflammation of tissue along the side of a toenail. The aim of the study was to asses and to compare effectiveness of electrocautery and phenol application in partial matrixectomy after partial nail extraction in the treatment of ingrown toenails. The group of 60 patients with ingrowing toenail which was randomized into two groups underwent partial matrixectomy in surgical outpatient clinic between 2009-2013. This group of patients was under surgical observation for 100 days in outpatient clinic. In all operated patients we obtained surgical success however we had 13 recurrences during the follow up period, 5 in the phenolization group and 8 in the electrocoagulation group. There was statistically significant difference between these two techniques, which indicated that matrix phenolization is connected with shortened healing time vs the matrix electrocoagulation.

  19. Complementary effect of patient volume and quality of care on hospital cost efficiency.

    Science.gov (United States)

    Choi, Jeong Hoon; Park, Imsu; Jung, Ilyoung; Dey, Asoke

    2017-06-01

    This study explores the direct effect of an increase in patient volume in a hospital and the complementary effect of quality of care on the cost efficiency of U.S. hospitals in terms of patient volume. The simultaneous equation model with three-stage least squares is used to measure the direct effect of patient volume and the complementary effect of quality of care and volume. Cost efficiency is measured with a data envelopment analysis method. Patient volume has a U-shaped relationship with hospital cost efficiency and an inverted U-shaped relationship with quality of care. Quality of care functions as a moderator for the relationship between patient volume and efficiency. This paper addresses the economically important question of the relationship of volume with quality of care and hospital cost efficiency. The three-stage least square simultaneous equation model captures the simultaneous effects of patient volume on hospital quality of care and cost efficiency.

  20. Three-dimensional reconstruction volume: a novel method for volume measurement in kidney cancer.

    Science.gov (United States)

    Durso, Timothy A; Carnell, Jonathan; Turk, Thomas T; Gupta, Gopal N

    2014-06-01

    The role of volumetric estimation is becoming increasingly important in the staging, management, and prognostication of benign and cancerous conditions of the kidney. We evaluated the use of three-dimensional reconstruction volume (3DV) in determining renal parenchymal volumes (RPV) and renal tumor volumes (RTV). We compared 3DV with the currently available methods of volume assessment and determined its interuser reliability. RPV and RTV were assessed in 28 patients who underwent robot-assisted laparoscopic partial nephrectomy for kidney cancer. Patients with a preoperative creatinine level of kidney pre- and postsurgery overestimated 3D reconstruction volumes by 15% to 102% and 12% to 101%, respectively. In addition, volumes obtained from 3DV displayed high interuser reliability regardless of experience. 3DV provides a highly reliable way of assessing kidney volumes. Given that 3DV takes into account visible anatomy, the differences observed using previously published methods can be attributed to the failure of geometry to accurately approximate kidney or tumor shape. 3DV provides a more accurate, reproducible, and clinically useful tool for urologists looking to improve patient care using analysis related to volume.

  1. Effect of Honey as Partial Sugar Substitute on Pasting Properties ...

    African Journals Online (AJOL)

    The effect of partial substitution of sugar with liquid honey on the pasting properties of cooked dough made from cassava-wheat composite (10:90) flour as well as the sensory preference and shelf stability of its bread was investigated. Sucrose (S) in the bread recipe formulation was substituted with honey (H) at levels 0, 10, ...

  2. Considerations and code for partial volume correcting [18F]-AV-1451 tau PET data

    Directory of Open Access Journals (Sweden)

    Suzanne L. Baker

    2017-12-01

    Full Text Available [18F]-AV-1451 is a leading tracer used with positron emission tomography (PET to quantify tau pathology. However, [18F]-AV-1451 shows “off target” or non-specific binding, which we define as binding of the tracer in unexpected areas unlikely to harbor aggregated tau based on autopsy literature [1]. Along with caudate, putamen, pallidum and thalamus non-specific binding [2,3], we have found binding in the superior portion of the cerebellar gray matter, leading us to use inferior cerebellar gray as the reference region. We also addressed binding in the posterior portion of the choroid plexus. PET signal unlikely to be associated with tau also occurs in skull, meninges and soft tissue (see e.g. [4]. We refer to [18F]-AV-1451 binding in the skull and meninges as extra-cortical hotspots (ECH and find them near lateral and medial orbitofrontal, lateral occipital, inferior and middle temporal, superior and inferior parietal, and inferior cerebellar gray matter. Lastly, the choroid plexus also shows non-specific binding that bleeds into hippocampus. We are providing the code (http://www.runmycode.org/companion/view/2798 used to create different regions of interest (ROIs that we then used to perform Partial Volume Correction (PVC using the Rousset geometric transfer matrix method (GTM, [5]. This method was used in the companion article, “Comparison of multiple tau-PET measures as biomarkers in aging and Alzheimer's Disease” ([6], DOI 10.1016/j.neuroimage.2017.05.058.

  3. Extended Excluded Volume: Its Origin and Consequences

    Czech Academy of Sciences Publication Activity Database

    Nezbeda, Ivo; Rouha, M.

    2013-01-01

    Roč. 85, č. 1 (2013), s. 201-210 ISSN 0033-4545. [International Conference on Solution Chemistry (ICSC-32) /32./. La Grande Motte, 28.08.2011-02.09.2011] R&D Projects: GA AV ČR IAA400720802 Institutional support: RVO:67985858 Keywords : excluded volume * partial molar volume * primitive models Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.112, year: 2013

  4. Effect of cadmium pretreatment on liver regeneration after partial hepatectomy in rats

    International Nuclear Information System (INIS)

    Margeli, A.; Theocharis, S.; Skaltsas, S.; Skopelitou, A.; Kittas, C.; Mykoniatis, M.; Varonos, D.

    1994-01-01

    In this study we examined the effect of cadmium pretreatment, administered 24 h before partial hepatectomy, on the liver regenerative process in rats, at different time intervals. The rate of 3 H thymidine incorporation into hepatic DNA and the activity of the enzyme thymidine kinase were used as indices of liver proliferative capacity. Thymidine kinase, the rate-determining enzyme of DNA biosynthesis, was suppressed during the first hours following partial hepatectomy in the liver of cadmium pretreated animals. DNA biosynthesis was also strongly decreased in cadmium pretreated animals, by delaying the first peak of liver regeneration, compared with the partially hepatectomized ones. Biochemical parameters, mitotic index and proliferating cell nuclear antigen staining were also coestimated. The above data suggest that cadmium pretreatment suppressed the hepatic regenerative process, probably due to the inhibition of thymidine kinase. (orig./MG)

  5. Influence of hydrostatic pressure on dynamics and spatial distribution of protein partial molar volume: time-resolved surficial Kirkwood-Buff approach.

    Science.gov (United States)

    Yu, Isseki; Tasaki, Tomohiro; Nakada, Kyoko; Nagaoka, Masataka

    2010-09-30

    The influence of hydrostatic pressure on the partial molar volume (PMV) of the protein apomyoglobin (AMb) was investigated by all-atom molecular dynamics (MD) simulations. Using the time-resolved Kirkwood-Buff (KB) approach, the dynamic behavior of the PMV was identified. The simulated time average value of the PMV and its reduction by 3000 bar pressurization correlated with experimental data. In addition, with the aid of the surficial KB integral method, we obtained the spatial distributions of the components of PMV to elucidate the detailed mechanism of the PMV reduction. New R-dependent PMV profiles identified the regions that increase or decrease the PMV under the high pressure condition. The results indicate that besides the hydration in the vicinity of the protein surface, the outer space of the first hydration layer also significantly influences the total PMV change. These results provide a direct and detailed picture of pressure induced PMV reduction.

  6. Factors influencing liver and spleen volume changes after donor hepatectomy for living donor liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Ji Hee; Ryeom, Hunku; Song, Jung Hup [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2013-11-15

    To define the changes in liver and spleen volumes in the early postoperative period after partial liver donation for living-donor liver transplantation (LDLT) and to determine factors that influence liver and spleen volume changes. 27 donors who underwent partial hepatectomy for LDLT were included in this study. The rates of liver and spleen volume change, measured with CT volumetry, were correlated with several factors. The analyzed factors included the indocyanine green (ICG) retention rate at 15 minutes after ICG administration, preoperative platelet count, preoperative liver and splenic volumes, resected liver volume, resected-to-whole liver volume ratio (LV{sub R}/LV{sub W}), resected liver volume to the sum of whole liver and spleen volume ratio [LV{sub R}/(LV{sub W} + SV{sub 0})], and pre and post hepatectomy portal venous pressures. In all hepatectomy donors, the volumes of the remnant liver and spleen were increased (increased rates, 59.5 ± 50.5%, 47.9 ± 22.6%). The increment rate of the remnant liver volume revealed a positive correlation with LV{sub R}/LV{sub W} (r = 0.759, p < 0.01). The other analyzed factors showed no correlation with changes in liver and spleen volumes. The spleen and remnant liver volumes were increased at CT volumetry performed 2 weeks after partial liver donation. Among the various analyzed factors, LV{sub R}/LV{sub W} influences the increment rate of the remnant liver volume.

  7. Effects of Time, Heat, and Oxygen on K Basin Sludge Agglomeration, Strength, and Solids Volume

    Energy Technology Data Exchange (ETDEWEB)

    Delegard, Calvin H.; Sinkov, Sergey I.; Schmidt, Andrew J.; Daniel, Richard C.; Burns, Carolyn A.

    2011-01-04

    Sludge disposition will be managed in two phases under the K Basin Sludge Treatment Project. The first phase is to retrieve the sludge that currently resides in engineered containers in the K West (KW) Basin pool at ~10 to 18°C. The second phase is to retrieve the sludge from interim storage in the sludge transport and storage containers (STSCs) and treat and package it in preparation for eventual shipment to the Waste Isolation Pilot Plant. The work described in this report was conducted to gain insight into how sludge may change during long-term containerized storage in the STSCs. To accelerate potential physical and chemical changes, the tests were performed at temperatures and oxygen partial pressures significantly greater than those expected in the T Plant canyon cells where the STSCs will be stored. Tests were conducted to determine the effects of 50°C oxygenated water exposure on settled quiescent uraninite (UO2) slurry and a full simulant of KW containerized sludge to determine the effects of oxygen and heat on the composition and mechanical properties of sludge. Shear-strength measurements by vane rheometry also were conducted for UO2 slurry, mixtures of UO2 and metaschoepite (UO3•2H2O), and for simulated KW containerized sludge. The results from these tests and related previous tests are compared to determine whether the settled solids in the K Basin sludge materials change in volume because of oxidation of UO2 by dissolved atmospheric oxygen to form metaschoepite. The test results also are compared to determine if heating or other factors alter sludge volumes and to determine the effects of sludge composition and settling times on sludge shear strength. It has been estimated that the sludge volume will increase with time because of a uranium metal → uraninite → metaschoepite oxidation sequence. This increase could increase the number of containers required for storage and increase overall costs of sludge management activities. However, the volume

  8. Effects of Time, Heat, and Oxygen on K Basin Sludge Agglomeration, Strength, and Solids Volume

    International Nuclear Information System (INIS)

    Delegard, Calvin H.; Sinkov, Sergey I.; Schmidt, Andrew J.; Daniel, Richard C.; Burns, Carolyn A.

    2011-01-01

    Sludge disposition will be managed in two phases under the K Basin Sludge Treatment Project. The first phase is to retrieve the sludge that currently resides in engineered containers in the K West (KW) Basin pool at ∼10 to 18 C. The second phase is to retrieve the sludge from interim storage in the sludge transport and storage containers (STSCs) and treat and package it in preparation for eventual shipment to the Waste Isolation Pilot Plant. The work described in this report was conducted to gain insight into how sludge may change during long-term containerized storage in the STSCs. To accelerate potential physical and chemical changes, the tests were performed at temperatures and oxygen partial pressures significantly greater than those expected in the T Plant canyon cells where the STSCs will be stored. Tests were conducted to determine the effects of 50 C oxygenated water exposure on settled quiescent uraninite (UO 2 ) slurry and a full simulant of KW containerized sludge to determine the effects of oxygen and heat on the composition and mechanical properties of sludge. Shear-strength measurements by vane rheometry also were conducted for UO 2 slurry, mixtures of UO2 and metaschoepite (UO 3 · 2H 2 O), and for simulated KW containerized sludge. The results from these tests and related previous tests are compared to determine whether the settled solids in the K Basin sludge materials change in volume because of oxidation of UO2 by dissolved atmospheric oxygen to form metaschoepite. The test results also are compared to determine if heating or other factors alter sludge volumes and to determine the effects of sludge composition and settling times on sludge shear strength. It has been estimated that the sludge volume will increase with time because of a uranium metal → uraninite → metaschoepite oxidation sequence. This increase could increase the number of containers required for storage and increase overall costs of sludge management activities. However, the

  9. Human Biomechanical and Cardiopulmonary Responses to Partial Gravity – A Systematic Review

    Directory of Open Access Journals (Sweden)

    Charlotte Richter

    2017-08-01

    Full Text Available The European Space Agency has recently announced to progress from low Earth orbit missions on the International Space Station to other mission scenarios such as exploration of the Moon or Mars. Therefore, the Moon is considered to be the next likely target for European human space explorations. Compared to microgravity (μg, only very little is known about the physiological effects of exposure to partial gravity (μg < partial gravity <1 g. However, previous research studies and experiences made during the Apollo missions comprise a valuable source of information that should be taken into account when planning human space explorations to reduced gravity environments. This systematic review summarizes the different effects of partial gravity (0.1–0.4 g on the human musculoskeletal, cardiovascular and respiratory systems using data collected during the Apollo missions as well as outcomes from terrestrial models of reduced gravity with either 1 g or microgravity as a control. The evidence-based findings seek to facilitate decision making concerning the best medical and exercise support to maintain astronauts' health during future missions in partial gravity. The initial search generated 1,323 publication hits. Out of these 1,323 publications, 43 studies were included into the present analysis and relevant data were extracted. None of the 43 included studies investigated long-term effects. Studies investigating the immediate effects of partial gravity exposure reveal that cardiopulmonary parameters such as heart rate, oxygen consumption, metabolic rate, and cost of transport are reduced compared to 1 g, whereas stroke volume seems to increase with decreasing gravity levels. Biomechanical studies reveal that ground reaction forces, mechanical work, stance phase duration, stride frequency, duty factor and preferred walk-to-run transition speed are reduced compared to 1 g. Partial gravity exposure below 0.4 g seems to be insufficient to maintain

  10. Densities and volume properties of (water + tert-butanol) over the temperature range of (274.15 to 348.15) K at pressure of 0.1 MPa

    International Nuclear Information System (INIS)

    Egorov, Gennadiy I.; Makarov, Dmitriy M.

    2011-01-01

    The densities of {water (1) + tert-butanol (2)} binary mixture were measured over the temperature range (274.15 to 348.15) K at atmospheric pressure using 'Anton Paar' digital vibrating-tube densimeter. Density measurements were carried out over the whole concentration range at (308.15 to 348.15) K. The following volume parameters were calculated: excess molar volumes and thermal isobaric expansivities of the mixture, partial molar volumes and partial molar thermal isobaric expansivities of the components. Concentration dependences of excess molar volumes were fitted with Redlich-Kister equation. The results of partial molar volume calculations using four equations were compared. It was established that for low alcohol concentrations at T ≤ 208 K the inflection points at x 2 ∼ 0.02 were observed at concentration dependences of specific volume. The concentration dependences of partial molar volumes of both water and tert-butanol had extremes at low alcohol content. The temperature dependence of partial molar volumes of water had some inversion at x 2 ∼ 0.65. The temperature dependence of partial molar volumes of tert-butanol at infinite dilution had minimum at ∼288 K. It was discovered that concentration dependences of thermal isobaric expansivities of the mixture at small alcohol content and low temperatures passed through minimum.

  11. The Partial Molar Volume and Compressibility of the FeO Component in Model Basalts (Mixed CaAl2Si2O8-CaMgSi2O6-CaFeSi2O6 Liquids) at 0 GPa: evidence of Fe2+ in 6-fold coordination

    Science.gov (United States)

    Guo, X.; Lange, R. A.; Ai, Y.

    2010-12-01

    FeO is an important component in magmatic liquids and yet its partial molar volume at one bar is not as well known as that for Fe2O3 because of the difficulty of performing double-bob density measurements under reducing conditions. Moreover, there is growing evidence from spectroscopic studies that Fe2+ occurs in 4, 5, and 6-fold coordination in silicate melts, and it is expected that the partial molar volume and compressibility of the FeO component will vary accordingly. We have conducted both density and relaxed sound speed measurements on four liquids in the An-Di-Hd (CaAl2Si2O8-CaMgSi2O6-CaFeSi2O6) system: (1) Di-Hd (50:50), (2) An-Hd (50:50), (3) An-Di-Hd (33:33:33) and (4) Hd (100). Densities were measured between 1573 and 1838 K at one bar with the double-bob Archimedean method using molybdenum bobs and crucibles in a reducing gas (1%CO-99%Ar) environment. The sound speeds were measured under similar conditions with a frequency-sweep acoustic interferometer, and used to calculate isothermal compressibility. All the density data for the three multi-component (model basalt) liquids were combined with density data on SiO2-Al2O3-CaO-MgO-K2O-Na2O liquids (Lange, 1997) in a fit to a linear volume equation; the results lead to a partial molar volume (±1σ) for FeO =11.7 ± 0.3(±1σ) cm3/mol at 1723 K. This value is similar to that for crystalline FeO at 298 K (halite structure; 12.06 cm3/mol), which suggests an average Fe2+ coordination of ~6 in these model basalt compositions. In contrast, the fitted partial molar volume of FeO in pure hedenbergite liquid is 14.6 ± 0.3 at 1723 K, which is consistent with an average Fe2+ coordination of 4.3 derived from EXAFS spectroscopy (Rossano, 2000). Similarly, all the compressibility data for the three multi-component liquids were combined with compressibility data on SiO2-Al2O3-CaO-MgO liquids (Ai and Lange, 2008) in a fit to an ideal mixing model for melt compressibility; the results lead to a partial molar

  12. How does knowledge of three-dimensional excision margins following breast conservation surgery impact upon clinical target volume definition for partial-breast radiotherapy?

    International Nuclear Information System (INIS)

    Kirby, Anna M.; Evans, Philip M.; Nerurkar, Ashutosh Y.; Desai, Saral S.; Krupa, Jaroslaw; Devalia, Haresh; Rovere, Guidubaldo Querci della; Harris, Emma J.; Kyriakidou, Julia; Yarnold, John R.

    2010-01-01

    Background and purpose: To compare partial-breast clinical target volumes generated using a standard 15 mm margin (CTV standard ) with those generated using three-dimensional surgical excision margins (CTV tailored30 ) in women who have undergone wide local excision (WLE) for breast cancer. Material and methods: Thirty-five women underwent WLE with placement of clips in the anterior, deep and coronal excision cavity walls. Distances from tumour to each of six margins were measured microscopically. Tumour bed was defined on kV-CT images using clips. CTV standard was generated by adding a uniform three-dimensional 15 mm margin, and CTV tailored30 was generated by adding 30 mm minus the excision margin in three-dimensions. Concordance between CTV standard and CTV tailored30 was quantified using conformity (CoI), geographical-miss (GMI) and normal-tissue (NTI) indices. An external-beam partial-breast irradiation (PBI) plan was generated to cover 95% of CTV standard with the 95% isodose. Percentage-volume coverage of CTV tailored30 by the 95% isodose was measured. Results: Median (range) coronal, superficial and deep excision margins were 15.0 (0.5-76.0) mm, 4.0 (0.0-60.0) mm and 4.0 (0.5-35.0) mm, respectively. Median CoI, GMI and NTI were 0.62, 0.16 and 0.20, respectively. Median coverage of CTV tailored30 by the PBI-plan was 97.7% (range 84.9-100.0%). CTV tailored30 was inadequately covered by the 95% isodose in 4/29 cases. In three cases, the excision margin in the direction of inadequate coverage was ≤2 mm. Conclusions: CTVs based on 3D excision margin data are discordant with those defined using a standard uniform 15 mm TB-CTV margin. In women with narrow excision margins, the standard TB-CTV margin could result in a geographical miss. Therefore, wider TB-CTV margins should be considered where re-excision does not occur.

  13. 18F-fluorocholine PET-guided target volume delineation techniques for partial prostate re-irradiation in local recurrent prostate cancer

    International Nuclear Information System (INIS)

    Wang Hui; Vees, Hansjoerg; Miralbell, Raymond; Wissmeyer, Michael; Steiner, Charles; Ratib, Osman; Senthamizhchelvan, Srinivasan; Zaidi, Habib

    2009-01-01

    Background and purpose: We evaluate the contribution of 18 F-choline PET/CT in the delineation of gross tumour volume (GTV) in local recurrent prostate cancer after initial irradiation using various PET image segmentation techniques. Materials and methods: Seventeen patients with local-only recurrent prostate cancer (median = 5.7 years) after initial irradiation were included in the study. Rebiopsies were performed in 10 patients that confirmed the local recurrence. Following injection of 300 MBq of 18 F-fluorocholine, dynamic PET frames (3 min each) were reconstructed from the list-mode acquisition. Five PET image segmentation techniques were used to delineate the 18 F-choline-based GTVs. These included manual delineation of contours (GTV man ) by two teams consisting of a radiation oncologist and a nuclear medicine physician each, a fixed threshold of 40% and 50% of the maximum signal intensity (GTV 40% and GTV 50% ), signal-to-background ratio-based adaptive thresholding (GTV SBR ), and a region growing (GTV RG ) algorithm. Geographic mismatches between the GTVs were also assessed using overlap analysis. Results: Inter-observer variability for manual delineation of GTVs was high but not statistically significant (p = 0.459). In addition, the volumes and shapes of GTVs delineated using semi-automated techniques were significantly higher than those of GTVs defined manually. Conclusions: Semi-automated segmentation techniques for 18 F-choline PET-guided GTV delineation resulted in substantially higher GTVs compared to manual delineation and might replace the latter for determination of recurrent prostate cancer for partial prostate re-irradiation. The selection of the most appropriate segmentation algorithm still needs to be determined.

  14. 18F-fluorocholine PET-guided target volume delineation techniques for partial prostate re-irradiation in local recurrent prostate cancer.

    Science.gov (United States)

    Wang, Hui; Vees, Hansjörg; Miralbell, Raymond; Wissmeyer, Michael; Steiner, Charles; Ratib, Osman; Senthamizhchelvan, Srinivasan; Zaidi, Habib

    2009-11-01

    We evaluate the contribution of (18)F-choline PET/CT in the delineation of gross tumour volume (GTV) in local recurrent prostate cancer after initial irradiation using various PET image segmentation techniques. Seventeen patients with local-only recurrent prostate cancer (median=5.7 years) after initial irradiation were included in the study. Rebiopsies were performed in 10 patients that confirmed the local recurrence. Following injection of 300 MBq of (18)F-fluorocholine, dynamic PET frames (3 min each) were reconstructed from the list-mode acquisition. Five PET image segmentation techniques were used to delineate the (18)F-choline-based GTVs. These included manual delineation of contours (GTV(man)) by two teams consisting of a radiation oncologist and a nuclear medicine physician each, a fixed threshold of 40% and 50% of the maximum signal intensity (GTV(40%) and GTV(50%)), signal-to-background ratio-based adaptive thresholding (GTV(SBR)), and a region growing (GTV(RG)) algorithm. Geographic mismatches between the GTVs were also assessed using overlap analysis. Inter-observer variability for manual delineation of GTVs was high but not statistically significant (p=0.459). In addition, the volumes and shapes of GTVs delineated using semi-automated techniques were significantly higher than those of GTVs defined manually. Semi-automated segmentation techniques for (18)F-choline PET-guided GTV delineation resulted in substantially higher GTVs compared to manual delineation and might replace the latter for determination of recurrent prostate cancer for partial prostate re-irradiation. The selection of the most appropriate segmentation algorithm still needs to be determined.

  15. Experimental and Simulation for the Effect of Partial Shading on Solar Panel Performance

    Directory of Open Access Journals (Sweden)

    Emad Talib Hahsim

    2016-06-01

    Full Text Available Partial shading is one of the problems that affects the power production and the efficiency of photovoltaic module. A series of experimental work have been done of partial shading of monocrystalline PV module; 50W, Isc: 3.1A, Voc: 22V with 36 cells in series is achieved. Non-linear power output responses of the module are observed by applying various cases of partial shading (vertical and horizontal shading of solar cells in the module. Shading a single cell (corner cell has the greatest impact on output energy. Horizontal shading or vertical shading reduced the power from 41W to 18W at constant solar radiation 1000W/m2 and steady state condition. Vertical blocking a column of cells (9 cells in a module reduces the power from 41W to 18W (53% power reduction; while, blocking one or two cell in the row reduces the power from 41 W to 18W (53% power reduction. Shading three or four cells in the same row reduces the power from 41W to 1W or 0.006W (94% power reduction. A complete Matlab / Simulink model are achieved to simulate the effect of partial shading on power output of module. It is found that shading a single cell reduces the power from 50 W to 25 W (50% using Matlab/Simulink model. Comparisons have been made between the I-V and P-V characteristic curves from the simulation with the practical (experimental curves. The results showed that the percentage of error between the Simulink results and the corresponding experimental measurement are 22% without shading effect and, 32% with partial shading.

  16. The effect of volume-of-interest misregistration on quantitative planar activity and dose estimation

    International Nuclear Information System (INIS)

    Song, N; Frey, E C; He, B

    2010-01-01

    In targeted radionuclide therapy (TRT), dose estimation is essential for treatment planning and tumor dose response studies. Dose estimates are typically based on a time series of whole-body conjugate view planar or SPECT scans of the patient acquired after administration of a planning dose. Quantifying the activity in the organs from these studies is an essential part of dose estimation. The quantitative planar (QPlanar) processing method involves accurate compensation for image degrading factors and correction for organ and background overlap via the combination of computational models of the image formation process and 3D volumes of interest defining the organs to be quantified. When the organ VOIs are accurately defined, the method intrinsically compensates for attenuation, scatter and partial volume effects, as well as overlap with other organs and the background. However, alignment between the 3D organ volume of interest (VOIs) used in QPlanar processing and the true organ projections in the planar images is required. The aim of this research was to study the effects of VOI misregistration on the accuracy and precision of organ activity estimates obtained using the QPlanar method. In this work, we modeled the degree of residual misregistration that would be expected after an automated registration procedure by randomly misaligning 3D SPECT/CT images, from which the VOI information was derived, and planar images. Mutual information-based image registration was used to align the realistic simulated 3D SPECT images with the 2D planar images. The residual image misregistration was used to simulate realistic levels of misregistration and allow investigation of the effects of misregistration on the accuracy and precision of the QPlanar method. We observed that accurate registration is especially important for small organs or ones with low activity concentrations compared to neighboring organs. In addition, residual misregistration gave rise to a loss of precision

  17. Market concentration, corporate governance and innovation: Partial and combined effects in US-listed firms

    Directory of Open Access Journals (Sweden)

    Mehmet Ugur

    2012-10-01

    Full Text Available Existing research on the relationship between market concentration and innovation has produced conflicting findings. In addition, the emerging literature on the relationship between corporate governance and innovation tends to focus only on partial effects of corporate governance on innovation. We aim to contribute to the debate by investigating both partial and combined effects of corporate governance and market concentration on innovation. Utilising a dataset for 1,400 non-financial US-listed companies and two-way cluster-robust estimation methodology, we report several findings. First, the relationship between market concentration and innovation is non-linear. Secondly, the relationship has a U-shape in the case of input measure of innovation (research and development - R&D – expenditures; but it has an inverted-U shape when net book-value of brands and patents is used as output measure of innovation. Third, corporate governance indicators such as anti-takeover defences and insider control tend to have a negative partial effect on R&D expenditures but a positive partial effect on net book-value of brands and patents. Finally, when interacted with market concentration, anti-takeover defences and insider control act as complements to market concentration. Hence, firms with strong anti-take-over defences and under insider control tend to spend more on R&D but are less able to generate valuable brands and patents as market concentration increases. These results are based on two-way cluster-robust estimation, which takes account of both serial and cross-sectional dependence in the error terms.

  18. Effect of high-volume systematic local infiltration analgesia in Caesarean section

    DEFF Research Database (Denmark)

    Larsen, Klaus Richter; Kristensen, B B; Rasmussen, M A

    2015-01-01

    BACKGROUND: Pain after Caesarean section is often treated with opioids with a risk of side effects. Wound infiltration with local anaesthetics is effective and has few side effects, but volume vs. dose concentration has not been examined. METHODS: Ninety patients scheduled for elective Caesarean...... found concerning time spent in the PACU, to first mobilisation or in number of women with nausea/vomiting (P ≥ 0.05). No complications related to ropivacaine were observed. CONCLUSIONS: Systematic infiltration with a high concentration, low volume compared with low concentration, high volume showed...

  19. Structure-volume relationships: singular volume effects produced by cupric ion-globular protein interaction.

    Science.gov (United States)

    Katz, S; Shinaberry, G; Heck, E L; Squire, W

    1980-08-05

    The nature of the volume isotherms produced by the coordination of Cu(II) with ovalbumin and bovine serum albumin differs substantially from the adsorption isotherms produced by these systems. Whereas there was increased binding of Cu(II) associated with a pH increase from pH 5.3 to pH 7.4, the volume isotherms for these systems did not exhibit this type of pH dependence. The volume changes were determined at 30.0 +/- 0.001 degrees C with microdilatometers which could be read to 0.01 muL. The binding isotherms for ovalbumin at pH 5.3 and 7.4 and for bovine serum albumin at pH 5.3 was resolved by a Scatchard plot to yield the appropriate thermodynamic parameters. An algorithm was derived to calculate the distribution of the individual PMi complexes, i.e., PMi-1 + M in equilibrium (Ki) PMi where i equals 1, 2, 3, ..., n moles of cation, M, bound per mole of protein, P, for the above systems. The volume isotherms were then resolved in terms of the constituent delta Vi terms, i.e., the volume change produced by the formation of the individual PMi complexes. These values were verified by an independent graphical differentiation procedure. The coordination of Cu(II) to BSA at pH 7.4 produced a cooperative adsorption isotherm which was not amenable to a Scatchard analysis. The resultant anomalous volume isotherm was resolved into a component related to Cu(II)-site interaction and a negative volume effect attributable to a conformational change induced by complex formation. This structural transition which occurs at physiological pH may constitute a control mechanism for regulating the serum level of Cu(II) and possibly other divalent ions.

  20. Partial splenic embolization in patients with idiopathic portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Maurizio E-mail: maurizio.romano@ibb.cnr.it; Giojelli, Angela; Capuano, Gaetano; Pomponi, Domenico; Salvatore, Marco

    2004-03-01

    Purpose: To evaluate the effectiveness of partial splenic embolization (PSE) in patients with idiopathic portal hypertension (IPH) in reducing variceal bleeding episodes, splenomegaly and thrombocytopenia. Materials and methods: Six patients (2M, 4F, mean age 30.3 years) with IPH presenting with splenomegaly, thrombocytopenia and recurrent variceal bleeding were treated with PSE using gelatin sponge (four patients) or Contour particles (two patients) as embolization material. Results: PSE was performed successfully in all cases; 3F coaxial microcatheters were necessary in two patients due to extreme splenic artery tortuosity. The average amount of devascularized parenchyma at CT 1 week after PSE was 71%. Splenomegaly and thrombocytopenia improved in all cases, with a mean platelet count increase of 120000/mm{sup 3} and an average 68% reduction of spleen volume at follow up. Variceal bleeding did not recur after PSE. Esophageal or gastroesophageal varices disappeared (one patient) or significantly reduced (five patients) at endoscopic controls. No significant complications were noted. The follow up was of at least 18 months in all patients; mean follow up was 28.2 months. Conclusion: In patients with IPH PSE can be effective in preventing variceal bleedings, in reducing spleen volume and in significantly increasing platelet count; therapeutic results were durable in our population.

  1. Ambient Occlusion Effects for Combined Volumes and Tubular Geometry

    KAUST Repository

    Schott, M.; Martin, T.; Grosset, A. V. P.; Smith, S. T.; Hansen, C. D.

    2013-01-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.

  2. Ambient Occlusion Effects for Combined Volumes and Tubular Geometry

    KAUST Repository

    Schott, M.

    2013-06-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.

  3. The effect of hospital volume on patient outcomes in severe acute pancreatitis

    Directory of Open Access Journals (Sweden)

    Shen Hsiu-Nien

    2012-08-01

    Full Text Available Abstract Background We investigated the relation between hospital volume and outcome in patients with severe acute pancreatitis (SAP. The determination is important because patient outcome may be improved through volume-based selective referral. Methods In this cohort study, we analyzed 22,551 SAP patients in 2,208 hospital-years (between 2000 and 2009 from Taiwan’s National Health Insurance Research Database. Primary outcome was hospital mortality. Secondary outcomes were hospital length of stay and charges. Hospital SAP volume was measured both as categorical and as continuous variables (per one case increase each hospital-year. The effect was assessed using multivariable logistic regression models with generalized estimating equations accounting for hospital clustering effect. Adjusted covariates included patient and hospital characteristics (model 1, and additional treatment variables (model 2. Results Irrespective of the measurements, increasing hospital volume was associated with reduced risk of hospital mortality after adjusting the patient and hospital characteristics (adjusted odds ratio [OR] 0.995, 95% confidence interval [CI] 0.993-0.998 for per one case increase. The patients treated in the highest volume quartile (≥14 cases per hospital-year had 42% lower risk of hospital mortality than those in the lowest volume quartile (1 case per hospital-year after adjusting the patient and hospital characteristics (adjusted OR 0.58, 95% CI 0.40-0.83. However, an inverse relation between volume and hospital stay or hospital charges was observed only when the volume was analyzed as a categorical variable. After adjusting the treatment covariates, the volume effect on hospital mortality disappeared regardless of the volume measures. Conclusions These findings support the use of volume-based selective referral for patients with SAP and suggest that differences in levels or processes of care among hospitals may have contributed to the volume

  4. Effects of partial time delays on phase synchronization in Watts-Strogatz small-world neuronal networks

    Science.gov (United States)

    Sun, Xiaojuan; Perc, Matjaž; Kurths, Jürgen

    2017-05-01

    In this paper, we study effects of partial time delays on phase synchronization in Watts-Strogatz small-world neuronal networks. Our focus is on the impact of two parameters, namely the time delay τ and the probability of partial time delay pdelay, whereby the latter determines the probability with which a connection between two neurons is delayed. Our research reveals that partial time delays significantly affect phase synchronization in this system. In particular, partial time delays can either enhance or decrease phase synchronization and induce synchronization transitions with changes in the mean firing rate of neurons, as well as induce switching between synchronized neurons with period-1 firing to synchronized neurons with period-2 firing. Moreover, in comparison to a neuronal network where all connections are delayed, we show that small partial time delay probabilities have especially different influences on phase synchronization of neuronal networks.

  5. Finite volume effects on the electric polarizability of neutral hadrons in lattice QCD

    Science.gov (United States)

    Lujan, M.; Alexandru, A.; Freeman, W.; Lee, F. X.

    2016-10-01

    We study the finite volume effects on the electric polarizability for the neutron, neutral pion, and neutral kaon using eight dynamically generated two-flavor nHYP-clover ensembles at two different pion masses: 306(1) and 227(2) MeV. An infinite volume extrapolation is performed for each hadron at both pion masses. For the neutral kaon, finite volume effects are relatively mild. The dependence on the quark mass is also mild, and a reliable chiral extrapolation can be performed along with the infinite volume extrapolation. Our result is αK0 phys=0.356 (74 )(46 )×10-4 fm3 . In contrast, for neutron, the electric polarizability depends strongly on the volume. After removing the finite volume corrections, our neutron polarizability results are in good agreement with chiral perturbation theory. For the connected part of the neutral pion polarizability, the negative trend persists, and it is not due to finite volume effects but likely sea quark charging effects.

  6. Excluded-volume effects in the diffusion of hard spheres

    KAUST Repository

    Bruna, Maria

    2012-01-03

    Excluded-volume effects can play an important role in determining transport properties in diffusion of particles. Here, the diffusion of finite-sized hard-core interacting particles in two or three dimensions is considered systematically using the method of matched asymptotic expansions. The result is a nonlinear diffusion equation for the one-particle distribution function, with excluded-volume effects enhancing the overall collective diffusion rate. An expression for the effective (collective) diffusion coefficient is obtained. Stochastic simulations of the full particle system are shown to compare well with the solution of this equation for two examples. © 2012 American Physical Society.

  7. Effect of Partial Replacement of Sand With Quarry Dust on the ...

    African Journals Online (AJOL)

    This work investigated the effect of partial replacement of sand with quarry dust on the compressive strength, flexural strength, split tensile strength and water absorption of sandcrete blocks. River sand was replaced with quarry dust at percentages ranging from 0 to 40 at cement/combined aggregate ratio of 1: 6. The blocks ...

  8. 293.15 K到333.15 K温度下一些氨基酸及其相应基团水溶液中的偏摩尔体积研究%Studies on Partial Molar Volumes of Some Amino Acids and Their Groups in Aqueous Solutions from 293.15 K to 333.15 K

    Institute of Scientific and Technical Information of China (English)

    赵长伟; 马沛生; 夏淑倩

    2004-01-01

    Densities of aqueous solutions of eight amino acids, glycine, L-alanine, L-valine, L-isoleucine, L-serine,L-threonine, L-arginine and L-phenylalanine, are measured as a function of amino acid concentration from 293.15 K to 333.15K. These data are used to calculate the apparent molar volume V and infinite dilution apparent molar volume V0 (partial molar volume). Data of five amino acids are used to correlate partial molar volume V0 using group contribution method to estimate the contributions of the zwitterionic end groups (NH3+,COO-) and CH2group, OH group, CNHNHNH2 group and C6H5(phenyl) group of amino acids. The results show that V0 values for all kinds of groups of amino acids studied increase with increase of temperature except those for CH2 group,which are almost constant within the studied temperature range. Data of other amino acids, L-valine, L-isoleucine and L-threonine, are chosen for comparison with the predicted partial molar volume V0 using the group additivity parameters obtained. The results confirm that this group additivity method has excellent predictive utility.

  9. WE-EF-BRA-11: Precision Partial-Tumor Irradiation of Dorsal Rodent Mammary Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Malcolm, J [Duke Medical Physics Graduate Program, Durham, NC (United States); Boss, K [Department of Comparative Biomedical Sciences, North Carolina State University (United States); Dewhirst, M [Dpt of Radiation and Cancer Biology, Duke University, Durham, North Carolina (United States); Oldham, M [Dpt of Radiation Oncology, Duke University Medical Center, Durham, NC (United States)

    2015-06-15

    Purpose: To introduce a pre-clinical treatment technique on a micro-irradiator to treat specific volumes of dorsal mammary tumors in BALB/c mice while sparing lungs and spine. This technique facilitates pre-clinical investigation of tumor response to sub-optimal radiation treatments in which a portion of the tumor is unirradiated, known as a “marginal miss”. In-vitro data suggests that partial tumor radiations trigger a more aggressive phenotype in non-irradiated, regional tumor cells via bystander effects. As the lung tissue is spared, the impact of marginal miss on the development of pulmonary metastasis may be assessed. Methods: End to end test was performed on three BALB/c mice as proof of concept for larger studies. 1Gy was delivered on the micro-irradiator employing previously unexplored lateral parallel-opposed diamond and/or triangle-shaped beams. The margins of the treatment beam were defined using a combination of tumor palpation, barium fiducial markers, and real-time fluoroscopic images. The dose distribution was independently verified with kilovoltage beam Monte Carlo dose calculations with 7% statistical uncertainty and double exposure images. As a final step, the technique was used in a larger pre-clinical study (15Gy, 36 BALB/c mice) and lung metastasis in response to tumor irradiation of 100%, 50% and 0% was quantified. Results: For the Monte-Carlo dose calculations, the dose volume histograms established a maximum dose within the un-irradiated and radiated portions of the mammary tumor of 0.3Gy and 1.5Gy respectively, with a sharp gradient at the boundary. 100% of the lung volume received less than 0.5Gy. This technique proved suitable for a pre-clinical marginal miss study with 50% more lung metastases in partially-radiated mouse models compared to completely. Conclusion: We have developed a novel treatment technique for partial or full irradiation of dorsal mammary tumors incorporating lung sparing.The technique will be useful for exploring

  10. 3D magneto-convective heat transfer in CNT-nanofluid filled cavity under partially active magnetic field

    Science.gov (United States)

    Al-Rashed, Abdullah A. A. A.; Kolsi, Lioua; Oztop, Hakan F.; Aydi, Abdelkarim; Malekshah, Emad Hasani; Abu-Hamdeh, Nidal; Borjini, Mohamed Naceur

    2018-05-01

    A computational study has been performed to investigate the effects of partially active magnetic field on natural convection heat transfer in CNT-nanofluid filled and three-dimensional differentially heated closed space. Two cases are considered to see this effect as magnetic field is applied to upper half (Case I) and lower half (Case II) while remaining walls are insulated. The finite volume method is used to solve governing equations and results are obtained for different governing parameters as Hartmann number (0 ≤ Ha ≤ 100), nanoparticle volume fraction (0 ≤ φ ≤ 0.05) and height of the active zone (0 ≤ LB ≤ 1). It is found that location of magnetic field plays an important role even at the same Hartmann number. Thus, it can be a good parameter to control heat and fluid flow inside the closed space.

  11. Flow rate measurement in a volume

    Energy Technology Data Exchange (ETDEWEB)

    Galvez, Cristhian

    2018-04-17

    A system for measuring flow rate within a volume includes one or more transmission devices that transmit one or more signals through fluid contained within the volume. The volume may be bounded, at least in part, by an outer structure and by an object at least partially contained within the outer structure. A transmission device located at a first location of the outer structure transmits a first signal to a second location of the outer structure. A second signal is transmitted through the fluid from the second location to a third location of the outer structure. The flow rate of the fluid within the volume may be determined based, at least in part, on the time of flight of both the first signal and the second signal.

  12. A lattice Boltzmann coupled to finite volumes method for solving phase change problems

    Directory of Open Access Journals (Sweden)

    El Ganaoui Mohammed

    2009-01-01

    Full Text Available A numerical scheme coupling lattice Boltzmann and finite volumes approaches has been developed and qualified for test cases of phase change problems. In this work, the coupled partial differential equations of momentum conservation equations are solved with a non uniform lattice Boltzmann method. The energy equation is discretized by using a finite volume method. Simulations show the ability of this developed hybrid method to model the effects of convection, and to predict transfers. Benchmarking is operated both for conductive and convective situation dominating solid/liquid transition. Comparisons are achieved with respect to available analytical solutions and experimental results.

  13. Effect of partial replacement of dietary maize with cassava peel meal ...

    African Journals Online (AJOL)

    Effect of dietary cassava peel meal (CPM) inclusion in partial replacement for maize on egg quality characteristics during storage was investigated in this study. In a completely randomized design, ISA brown pullets (n=3,000) aged 20-week were assigned to three dietary treatments. Diets A, B, C contained CPM at 0, 10 and ...

  14. Finite Volumes for Complex Applications VII

    CERN Document Server

    Ohlberger, Mario; Rohde, Christian

    2014-01-01

    The methods considered in the 7th conference on "Finite Volumes for Complex Applications" (Berlin, June 2014) have properties which offer distinct advantages for a number of applications. The second volume of the proceedings covers reviewed contributions reporting successful applications in the fields of fluid dynamics, magnetohydrodynamics, structural analysis, nuclear physics, semiconductor theory and other topics. The finite volume method in its various forms is a space discretization technique for partial differential equations based on the fundamental physical principle of conservation. Recent decades have brought significant success in the theoretical understanding of the method. Many finite volume methods preserve further qualitative or asymptotic properties, including maximum principles, dissipativity, monotone decay of free energy, and asymptotic stability. Due to these properties, finite volume methods belong to the wider class of compatible discretization methods, which preserve qualitative propert...

  15. Heat deposition on the partial limiter

    International Nuclear Information System (INIS)

    Itoh, Kimitaka; Itoh, Sanae-I; Nagasaki, Kazunobu.

    1990-01-01

    The effect of the partial limiter in the outermost magnetic surface of toroidal plasmas is studied. The power deposition on the partial limiter and its effect on the temperature profile are analysed. Interpretation in terms of the perpendicular heat conductivity is also discussed. (author)

  16. A Virtual Reality System for PTCD Simulation Using Direct Visuo-Haptic Rendering of Partially Segmented Image Data.

    Science.gov (United States)

    Fortmeier, Dirk; Mastmeyer, Andre; Schröder, Julian; Handels, Heinz

    2016-01-01

    This study presents a new visuo-haptic virtual reality (VR) training and planning system for percutaneous transhepatic cholangio-drainage (PTCD) based on partially segmented virtual patient models. We only use partially segmented image data instead of a full segmentation and circumvent the necessity of surface or volume mesh models. Haptic interaction with the virtual patient during virtual palpation, ultrasound probing and needle insertion is provided. Furthermore, the VR simulator includes X-ray and ultrasound simulation for image-guided training. The visualization techniques are GPU-accelerated by implementation in Cuda and include real-time volume deformations computed on the grid of the image data. Computation on the image grid enables straightforward integration of the deformed image data into the visualization components. To provide shorter rendering times, the performance of the volume deformation algorithm is improved by a multigrid approach. To evaluate the VR training system, a user evaluation has been performed and deformation algorithms are analyzed in terms of convergence speed with respect to a fully converged solution. The user evaluation shows positive results with increased user confidence after a training session. It is shown that using partially segmented patient data and direct volume rendering is suitable for the simulation of needle insertion procedures such as PTCD.

  17. Partial mGlu₅ Negative Allosteric Modulators Attenuate Cocaine-Mediated Behaviors and Lack Psychotomimetic-Like Effects.

    Science.gov (United States)

    Gould, Robert W; Amato, Russell J; Bubser, Michael; Joffe, Max E; Nedelcovych, Michael T; Thompson, Analisa D; Nickols, Hilary H; Yuh, Johannes P; Zhan, Xiaoyan; Felts, Andrew S; Rodriguez, Alice L; Morrison, Ryan D; Byers, Frank W; Rook, Jerri M; Daniels, John S; Niswender, Colleen M; Conn, P Jeffrey; Emmitte, Kyle A; Lindsley, Craig W; Jones, Carrie K

    2016-03-01

    Cocaine abuse remains a public health concern for which pharmacotherapies are largely ineffective. Comorbidities between cocaine abuse, depression, and anxiety support the development of novel treatments targeting multiple symptom clusters. Selective negative allosteric modulators (NAMs) targeting the metabotropic glutamate receptor 5 (mGlu5) subtype are currently in clinical trials for the treatment of multiple neuropsychiatric disorders and have shown promise in preclinical models of substance abuse. However, complete blockade or inverse agonist activity by some full mGlu5 NAM chemotypes demonstrated adverse effects, including psychosis in humans and psychotomimetic-like effects in animals, suggesting a narrow therapeutic window. Development of partial mGlu5 NAMs, characterized by their submaximal but saturable levels of blockade, may represent a novel approach to broaden the therapeutic window. To understand potential therapeutic vs adverse effects in preclinical behavioral assays, we examined the partial mGlu5 NAMs, M-5MPEP and Br-5MPEPy, in comparison with the full mGlu5 NAM MTEP across models of addiction and psychotomimetic-like activity. M-5MPEP, Br-5MPEPy, and MTEP dose-dependently decreased cocaine self-administration and attenuated the discriminative stimulus effects of cocaine. M-5MPEP and Br-5MPEPy also demonstrated antidepressant- and anxiolytic-like activity. Dose-dependent effects of partial and full mGlu5 NAMs in these assays corresponded with increasing in vivo mGlu5 occupancy, demonstrating an orderly occupancy-to-efficacy relationship. PCP-induced hyperlocomotion was potentiated by MTEP, but not by M-5MPEP and Br-5MPEPy. Further, MTEP, but not M-5MPEP, potentiated the discriminative-stimulus effects of PCP. The present data suggest that partial mGlu5 NAM activity is sufficient to produce therapeutic effects similar to full mGlu5 NAMs, but with a broader therapeutic index.

  18. Ecological effects of full and partial protection in the crowded Mediterranean Sea: a regional meta-analysis

    DEFF Research Database (Denmark)

    Giakoumi, Sylvaine; Scianna, Claudia; Plass-Johnson, Jeremiah Grahm

    2017-01-01

    the relationships between the level of protection and MPA size, age, and enforcement. Results revealed significant positive effects of protection for fisheries target species and negative effects for urchins as their predators benefited from protection. Full protection provided stronger effects than partial...... to inform decisions. In the human-dominated Mediterranean Sea, fully protected areas occupy only 0.04% of its surface. We evaluated the impacts of full and partial protection on biomass and density of fish assemblages, some commercially important fishes, and sea urchins in 24 Mediterranean MPAs. We explored...

  19. Effective orbital volume and eyeball position: an MRI study.

    Science.gov (United States)

    Detorakis, Efstathios T; Drakonaki, Eleni; Papadaki, Efrosini; Pallikaris, Ioannis G; Tsilimbaris, Miltiadis K

    2010-10-01

    Previous studies have examined factors affecting the position of the eyeball to the orbit. This study examined the role of effective orbital volume (EOV), defined as the difference between orbital and eyeball volume, as a determinant of eyeball position, using MRI scans. Forty-six patients were recruited from the Department of Ophthalmology of the University Hospital of Heraklion, Crete Greece. Patients with a history of orbital disease were excluded. Distances between eyeball poles and orbital landmarks were measured in T1 weighted transverse, sagittal and coronal orbital images. The protrusion of the eyeball in the sagittal and transverse planes was recorded. The volume of the eyeball and bony orbit, the EOV, the volume of the extraocular muscles as well as clinical information (age, gender, Hertel exophthalmometry) were also recorded. EOV was significantly associated with orbital volume but not with eyeball volume. EOV was also significantly associated with transverse and sagittal globe protrusions. Females displayed significantly lower orbital and eyeball volumes as well as EOV than males but higher transverse globe protrusion than males. Variations in EOV are associated with orbital volume rather than with eyeball volume. EOV is associated with globe protrusion and may be taken into account in the planning of various procedures, including orbital decompression, treatment of enophthalmos or the size of orbital implants following enucleation.

  20. Hyperbolic partial differential equations populations, reactors, tides and waves theory and applications

    CERN Document Server

    Witten, Matthew

    1983-01-01

    Hyperbolic Partial Differential Equations, Volume 1: Population, Reactors, Tides and Waves: Theory and Applications covers three general areas of hyperbolic partial differential equation applications. These areas include problems related to the McKendrick/Von Foerster population equations, other hyperbolic form equations, and the numerical solution.This text is composed of 15 chapters and begins with surveys of age specific population interactions, populations models of diffusion, nonlinear age dependent population growth with harvesting, local and global stability for the nonlinear renewal eq

  1. Finite-volume effects due to spatially non-local operators arXiv

    CERN Document Server

    Briceño, Raúl A.; Hansen, Maxwell T.; Monahan, Christopher J.

    Spatially non-local matrix elements are useful lattice-QCD observables in a variety of contexts, for example in determining hadron structure. To quote credible estimates of the systematic uncertainties in these calculations, one must understand, among other things, the size of the finite-volume effects when such matrix elements are extracted from numerical lattice calculations. In this work, we estimate finite-volume effects for matrix elements of non-local operators, composed of two currents displaced in a spatial direction by a distance $\\xi$. We find that the finite-volume corrections depend on the details of the matrix element. If the external state is the lightest degree of freedom in the theory, e.g.~the pion in QCD, then the volume corrections scale as $ e^{-m_\\pi (L- \\xi)} $, where $m_\\pi$ is the mass of the light state. For heavier external states the usual $e^{- m_\\pi L}$ form is recovered, but with a polynomial prefactor of the form $L^m/|L - \\xi|^n$ that can lead to enhanced volume effects. These ...

  2. 2016 Billion-Ton Report: Environmental Sustainability Effects of Select Scenarios from Volume 1 (Volume 2)

    Energy Technology Data Exchange (ETDEWEB)

    Efroymson, R. A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Langholtz, M. H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Johnson, K. E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Stokes, B. J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-01-13

    On behalf of all the authors and contributors, it is a great privilege to present the 2016 Billion-Ton Report (BT16), volume 2: Environmental Sustainability Effects of Select Scenarios from volume 1. This report represents the culmination of several years of collaborative effort among national laboratories, government agencies, academic institutions, and industry. BT16 was developed to support the U.S. Department of Energy’s efforts towards national goals of energy security and associated quality of life.

  3. Dedicated Perioperative Hip Fracture Comanagement Programs are Cost-effective in High-volume Centers: An Economic Analysis.

    Science.gov (United States)

    Swart, Eric; Vasudeva, Eshan; Makhni, Eric C; Macaulay, William; Bozic, Kevin J

    2016-01-01

    a full-time basis. Additionally, we evaluated the scenario where the necessary staff was already employed at the hospital and could be dedicated to a comanagement service on a part-time basis, and explored the effect of triaging only patients considered high risk to a comanagement service versus comanaging all geriatric patients. Finally, probabilistic sensitivity analysis was conducted on all critical variables, with broad ranges used for values around which there was higher uncertainty. For the base case, universal comanagement was more cost effective than traditional care and risk-stratified comanagement (incremental cost effectiveness ratios of USD 41,100 per quality-adjusted life-year and USD 81,900 per quality-adjusted life-year, respectively). Comanagement was more cost effective than traditional management as long as the case volume was more than 54 patients annually (range, 41-68 patients based on sensitivity analysis) and resulted in cost savings when there were more than 318 patients annually (range, 238-397 patients). In a scenario where staff could be partially dedicated to a comanagement service, universal comanagement was more cost effective than risk-stratified comanagement (incremental cost effectiveness of USD 2300 per quality-adjusted life-year), and both comanagement programs had lower costs and better outcomes compared with traditional management. Sensitivity analysis was conducted and showed that the level of uncertainty in key variables was not high enough to change the core conclusions of the model. Implementation of a systems-based comanagement strategy using a dedicated team to improve perioperative medical care and expedite preoperative evaluation is cost effective in hospitals with moderate volume and can result in cost savings at higher-volume centers. The optimum patient population for a comanagement strategy is still being defined. Level 1, Economic and Decision Analysis.

  4. Apparent molal volumes of symmetrical and asymmetrical isomers of tetrabutylammonium bromide in water at several temperatures

    International Nuclear Information System (INIS)

    Moreno, Nicolás; Malagón, Andrés; Buchner, Richard; Vargas, Edgar F.

    2014-01-01

    Highlights: • Apparent molal volumes of five isomers of Bu 4 NBr in water have been measured. • The structural effect of branched and linear chains is discussed. • The structural contributions to the ionic volume were calculated. -- Abstract: Apparent molal volumes of a series of differently substituted quaternary ammonium bromides, namely tetra-iso-butyl-, tetra-sec-butyl-, tetra-n-butyl-, di-n-butyl-di-sec-butyl- and di-n-butyl-di-iso-butylammonium bromide have been determined as a function of molal concentration at (298.15, 303.15 and 308.15) K. Partial molar volumes at infinite dilution and ionic molar volumes of these quaternary ammonium cations were determined. Structural volume contributions to the ionic molar volume were also calculated. The symmetric and asymmetric quaternary ammonium cations are “structure making” ions. The contribution of the branched butyl chains predominates over the linear butyl chains in the asymmetric cations

  5. The Effects of Partial Replacement of Maize with Plantain Peels in ...

    African Journals Online (AJOL)

    A 28-day feeding trial involving one hundred and twenty (120) 1-week-old Anak starter broilers was carried out in a completely randomized design to evaluate the effect of partial replacement of maize with unripe plantain peel meals at 0, 4, 8 and 12% dietary levels on the performance of broilers. Data were collected on feed ...

  6. Effects of partial crystallinity and quenched-in defects on corrosion of ...

    Indian Academy of Sciences (India)

    Rapid solidification by planar flow casting has been found to have introduced deficiencies, viz. partial crystallinity, air pockets and compositional difference in the ribbons of rapidly solidified Ti42.9-Cu57.1 alloy. In order to investigate the effects of these deficiencies on the corrosion of rapidly solidified Ti42.9-Cu57.1 alloy ...

  7. Statistical representative elementary volumes of porous media determined using greyscale analysis of 3D tomograms

    Science.gov (United States)

    Bruns, S.; Stipp, S. L. S.; Sørensen, H. O.

    2017-09-01

    Digital rock physics carries the dogmatic concept of having to segment volume images for quantitative analysis but segmentation rejects huge amounts of signal information. Information that is essential for the analysis of difficult and marginally resolved samples, such as materials with very small features, is lost during segmentation. In X-ray nanotomography reconstructions of Hod chalk we observed partial volume voxels with an abundance that limits segmentation based analysis. Therefore, we investigated the suitability of greyscale analysis for establishing statistical representative elementary volumes (sREV) for the important petrophysical parameters of this type of chalk, namely porosity, specific surface area and diffusive tortuosity, by using volume images without segmenting the datasets. Instead, grey level intensities were transformed to a voxel level porosity estimate using a Gaussian mixture model. A simple model assumption was made that allowed formulating a two point correlation function for surface area estimates using Bayes' theory. The same assumption enables random walk simulations in the presence of severe partial volume effects. The established sREVs illustrate that in compacted chalk, these simulations cannot be performed in binary representations without increasing the resolution of the imaging system to a point where the spatial restrictions of the represented sample volume render the precision of the measurement unacceptable. We illustrate this by analyzing the origins of variance in the quantitative analysis of volume images, i.e. resolution dependence and intersample and intrasample variance. Although we cannot make any claims on the accuracy of the approach, eliminating the segmentation step from the analysis enables comparative studies with higher precision and repeatability.

  8. Interactions of glutamine dipeptides with sodium dodecyl sulfate in aqueous solution measured by volume, conductivity, and fluorescence spectra

    Energy Technology Data Exchange (ETDEWEB)

    Yan Zhenning, E-mail: yanzzn@zzu.edu.cn [Department of Chemistry, Zhengzhou University, Zhengzhou, Henan 450001 (China); Sun Ximeng; Li Weiwei; Li Yu [Department of Chemistry, Zhengzhou University, Zhengzhou, Henan 450001 (China); Wang Jianji [Department of Chemistry, Henan Normal University, Xinxiang, Henan 453007 (China)

    2011-10-15

    Highlights: > Ion-ion and ion-polar group interactions are dominant interactions. > The SDS addition and temperature increase cause a dehydration effect on dipeptides. > The addition of dipeptide in water decreases the c{sub cmc} of SDS. > Enthalpy-entropy compensation takes place during micellization. > Micelle aggregation number was decreased by addition of glutamine dipeptides. - Abstract: Densities, conductivities, and fluorescence spectra of {l_brace}sodium dodecyl sulfate (SDS) + glutamine dipeptide + water{r_brace} mixtures were measured as a function of temperature. The density data have been utilized to calculate apparent molar volumes, standard partial molar volumes (V{sub 2,{phi}}{sup o}), standard partial molar volumes of transfer from water to aqueous SDS solutions ({Delta}{sub t}V{sup o}), the hydration number, partial molar expansibility (E{sub {phi}}{sup o}), and Hepler's constant of glutamine dipeptides. The critical micellar concentration (c{sub cmc}) and the degree of counterion dissociation of SDS micelles obtained from electrical conductivity data have been estimated at various concentrations of glutamine dipeptide. Thermodynamic parameters of micellization of SDS in aqueous dipeptide solutions have been determined from c{sub cmc} values and an enthalpy-entropy compensation effect was observed for the ternary systems. The pyrene fluorescence spectra were used to study the change of micropolarity produced by the interaction of SDS with glutamine dipeptide, and the aggregation behavior of SDS. The results have been interpreted in terms of solute-solvent interactions and structural changes in the mixed solutions.

  9. Effect of hospital volume on processes of breast cancer care: A National Cancer Data Base study.

    Science.gov (United States)

    Yen, Tina W F; Pezzin, Liliana E; Li, Jianing; Sparapani, Rodney; Laud, Purushuttom W; Nattinger, Ann B

    2017-05-15

    The purpose of this study was to examine variations in delivery of several breast cancer processes of care that are correlated with lower mortality and disease recurrence, and to determine the extent to which hospital volume explains this variation. Women who were diagnosed with stage I-III unilateral breast cancer between 2007 and 2011 were identified within the National Cancer Data Base. Multiple logistic regression models were developed to determine whether hospital volume was independently associated with each of 10 individual process of care measures addressing diagnosis and treatment, and 2 composite measures assessing appropriateness of systemic treatment (chemotherapy and hormonal therapy) and locoregional treatment (margin status and radiation therapy). Among 573,571 women treated at 1755 different hospitals, 38%, 51%, and 10% were treated at high-, medium-, and low-volume hospitals, respectively. On multivariate analysis controlling for patient sociodemographic characteristics, treatment year and geographic location, hospital volume was a significant predictor for cancer diagnosis by initial biopsy (medium volume: odds ratio [OR] = 1.15, 95% confidence interval [CI] = 1.05-1.25; high volume: OR = 1.30, 95% CI = 1.14-1.49), negative surgical margins (medium volume: OR = 1.15, 95% CI = 1.06-1.24; high volume: OR = 1.28, 95% CI = 1.13-1.44), and appropriate locoregional treatment (medium volume: OR = 1.12, 95% CI = 1.07-1.17; high volume: OR = 1.16, 95% CI = 1.09-1.24). Diagnosis of breast cancer before initial surgery, negative surgical margins and appropriate use of radiation therapy may partially explain the volume-survival relationship. Dissemination of these processes of care to a broader group of hospitals could potentially improve the overall quality of care and outcomes of breast cancer survivors. Cancer 2017;123:957-66. © 2016 American Cancer Society. © 2016 American Cancer Society.

  10. The effectiveness of adhesives on the retention of mandibular free end saddle partial dentures: An in vitro study.

    Science.gov (United States)

    Quiney, Daniel; Nishio Ayre, Wayne; Milward, Paul

    2017-07-01

    Existing in vitro methods for testing denture adhesives do not fully replicate the complex oral geometries and environment; and in vivo methods are qualitative, prone to bias and not easily reproducible. The purpose of this study was to develop a novel, quantitative and more accurate model to test the effect of adhesives on the retentive force of mandibular free end saddle partial dentures. An in vitro model was developed based on an anatomically accurate cast of a clinical case. Experimentally, the amount of adhesive was varied (0.2g-1g) and the tensile force required for displacement was measured. Different commercially available adhesives were then tested at the optimum volume using the in vitro model. A 3D finite element model of the denture was used to assess how the forces to induce denture displacement varied according to the position of the force along the saddle length. The mass of adhesive was found to significantly alter retention forces, with 0.4-0.7g being the optimum range for this particular scenario. Use of adhesives significantly improved mandibular free end saddle partial denture retention with the worst performing adhesive increasing retention nine-fold whilst the best performing adhesive increased retention twenty three-fold. The finite element model revealed that 77% more force was required to displace the denture by positioning forces towards the mesial end of the saddle compared to the distal end. An in vitro denture adhesive model was developed, which demonstrated that mass of adhesive plays a significant role in enhancing denture retention and supported the design principle of placing as few teeth as clinically necessary on the distal end of the free end saddles. Limiting the position of teeth on free end saddles to the mesial and mid portion of the saddle will reduce displacements caused by mastication. The movement of mandibular free end saddle partial dentures can be restricted with the use of denture adhesives. Altering the mass of

  11. The Effects of Partial Turbinectomy on Patients Undergoing Rhinoplasty

    Directory of Open Access Journals (Sweden)

    Behrooz Gandomi

    2011-03-01

    Full Text Available Introduction: A reduction or cessation of the ability to breathe through the nose can affect a person's overall health. Nasal passage blockage can also result in snoring. Difficulty in breathing through the nose after rhinoplasty is a serious problem and patient dissatisfaction can be significant even when cosmetic results are excellent. Long-term impacts on the quality of life and contributions to the pathophysiology of sleep-related breathing disorders have both been documented. This study compares nasal obstruction and other prevalent respiratory side effects of rhinoplasty in the presence and absence of partial turbinectomy. Methods and Materials: This is an experimental case study conducted in 2007 on patients undergoing rhinoplastic surgery in Shahid Dastgheyb Hospital of Shiraz, Iran. Sampling was done on all admitted patients during this year in the mentioned hospital. For the first group, rhinoplasty plus partial turbinectomy was performed while taking into consideration the Helsinki criteria septorhinoplasty without partial turbinectomy was performed on the second group. P-value less than 0.05 was considered as statistically significant. Results: There was no significant difference between the case and control group in terms of their mean age and gender distribution. Respiratory mean scores before and after rhinoplasty in both groups were significantly different in some issues of Nasal Scale (i.e.: Nasal blockage or obstruction, trouble sleeping, inability to get enough air through the nose during exercise or exertion, trouble breathing through nose.  Conclusion: Achieving cosmetic goals while preserving such necessary functions is a great concern for rhinologists and this makes different complexes. To create a balance between the maximum physiologic function and the best cosmetic feature is an art.

  12. Turbulent piloted partially-premixed flames with varying levels of O2/N2: stability limits and PDF calculations

    Science.gov (United States)

    Juddoo, Mrinal; Masri, Assaad R.; Pope, Stephen B.

    2011-12-01

    This paper reports measured stability limits and PDF calculations of piloted, turbulent flames of compressed natural gas (CNG) partially-premixed with either pure oxygen, or with varying levels of O2/N2. Stability limits are presented for flames of CNG fuel premixed with up to 20% oxygen as well as CNG-O2-N2 fuel where the O2 content is varied from 8 to 22% by volume. Calculations are presented for (i) Sydney flame B [Masri et al. 1988] which uses pure CNG as well as flames B15 to B25 where the CNG is partially-premixed with 15-25% oxygen by volume, respectively and (ii) Sandia methane-air (1:3 by volume) flame E [Barlow et al. 2005] as well as new flames E15 and E25 that are partially-premixed with 'reconstituted air' where the O2 content in nitrogen is 15 and 25% by volume, respectively. The calculations solve a transported PDF of composition using a particle-based Monte Carlo method and employ the EMST mixing model as well as detailed chemical kinetics. The addition of oxygen to the fuel increases stability, shortens the flames, broadens the reaction zone, and shifts the stoichiometric mixture fraction towards the inner side of the jet. It is found that for pure CNG flames where the reaction zone is narrow (∼0.1 in mixture fraction space), the PDF calculations fail to reproduce the correct level of local extinction on approach to blow-off. A broadening in the reaction zone up to about 0.25 in mixture fraction space is needed for the PDF/EMST approach to be able to capture these finite-rate chemistry effects. It is also found that for the same level of partial premixing, increasing the O2/N2 ratio increases the maximum levels of CO and NO but shifts the peak to richer mixture fractions. Over the range of oxygenation investigated here, stability limits have shown to improve almost linearly with increasing oxygen levels in the fuel and with increasing the contribution of release rate from the pilot.

  13. Effective moduli of high volume fraction particulate composites

    International Nuclear Information System (INIS)

    Kwon, P.; Dharan, C.K.H.

    1995-01-01

    Predictions using current micromechanics theories for the effective moduli of particulate-reinforced composites tend to break down at high volume fractions of the reinforcing phase. The predictions are usually well below experimentally measured values of the Young's modulus for volume fractions exceeding about 0.6. In this paper, the concept of contiguity, which is a measure of phase continuity, is applied to Mori-Tanaka micromechanics theory. It is shown that contiguity of the second phase increases with volume fraction, leading eventually to a reversal in the roles of the inclusion and matrix. In powder metallurgy practice, it is well known that at high volume fractions, sintering and consolidation of the reinforcement make it increasingly continuous and more like the matrix phase, while the former matrix tends to become more like the inclusion phase. The concept of contiguity applied to micromechanics theory results in very good agreement between the predicted Young's modulus and experimental data on tungsten carbide particulate-reinforced cobalt

  14. Numerical Methods for Partial Differential Equations

    CERN Document Server

    Guo, Ben-yu

    1987-01-01

    These Proceedings of the first Chinese Conference on Numerical Methods for Partial Differential Equations covers topics such as difference methods, finite element methods, spectral methods, splitting methods, parallel algorithm etc., their theoretical foundation and applications to engineering. Numerical methods both for boundary value problems of elliptic equations and for initial-boundary value problems of evolution equations, such as hyperbolic systems and parabolic equations, are involved. The 16 papers of this volume present recent or new unpublished results and provide a good overview of current research being done in this field in China.

  15. Deriving implicit user feedback from partial URLs for effective web page retrieval

    NARCIS (Netherlands)

    Li, R.; van der Weide, Theo

    2010-01-01

    User click-throughs provide a search context for understanding the user need of complex information. This paper re-examines the effectiveness of this approach when based on partial clicked data using the language modeling framework. We expand the original query by topical terms derived from clicked

  16. Apparent molar volumes and compressibilities of lanthanum, gadolinium and lutetium trifluoromethanesulfonates in dimethylsulfoxide

    International Nuclear Information System (INIS)

    Warmińska, Dorota; Wawer, Jarosław

    2012-01-01

    Highlights: ► Sequence of volumes and compressibilities of Ln 3+ ions in DMSO is: La 3+ > Gd 3+ 3+ . ► Sequence of the partial molar volumes do not change with temperature. ► These results are the consequence of nature of the ion–solvent bonding. - Abstract: Temperature dependencies of the densities of dimethylsulfoxide solutions of lanthanum, gadolinium and lutetium trifluoromethanesulfonates have been determined over a wide range of concentrations. The apparent molar volumes and partial molar volumes of the salts at infinite dilution, as well as the expansibilities of the salts, have been calculated from density data. Additionally, the apparent molar isentropic compressibilities of lanthanum, gadolinium and lutetium trifluoromethanesulfonates have been calculated from sound velocity data at 298.15 K. The data obtained have been interpreted in terms of ion−solvent interactions.

  17. Report on ISS Oxygen Production, Resupply, and Partial Pressure Management

    Science.gov (United States)

    Schaezler, Ryan; Ghariani, Ahmed; Leonard, Daniel; Lehman, Daniel

    2011-01-01

    The majority of oxygen used on International Space Station (ISS) is for metabolic support and denitrogenation procedures prior to Extra-Vehicular Activities. Oxygen is supplied by various visiting vehicles such as the Progress and Shuttle in addition to oxygen production capability on both the United States On-Orbit Segment (USOS) and Russian Segment (RS). To maintain a habitable atmosphere the oxygen partial pressure is controlled between upper and lower bounds. The full range of the allowable oxygen partial pressure along with the increased ISS cabin volume is utilized as a buffer allowing days to pass between oxygen production or direct addition of oxygen to the atmosphere from reserves. This paper summarizes amount of oxygen supplied and produced from all of the sources and describes past experience of managing oxygen partial pressure along with the range of management options available to the ISS.

  18. Toxicity and cosmetic outcome of three-dimensional conformal radiotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Gatti, M.; Bresciani, S.; Ponzone, R.; Panaia, R.; Salatino, A.; Stasi, M.; Gabriele, P.

    2011-01-01

    Full text of publication follows: Purpose.- To analyse the incidence and severity of acute and late normal tissue toxicity and cosmetic outcome using three - dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Patients and Methods.- 70 patients with stage I disease were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation, in an approved protocol. The prescribed dose was 34 Gy in all patients delivered in 10 fractions over 5 consecutive days. On all CT scans gross tumor volume (GTV ) was defined around surgical clips. A 1.5 cm margin was added in order to account for clinical target volume (CTV) . A margin of 1 cm was added to CTI to define the planning target volume (PTV). The dose-volume constraints were followed in accordance with the specifications as dictated in the NSABP/RTOG protocol. After treatment, patients underwent a clinical and cosmetic evaluation every 3 months. Late toxicity was evaluated according to the RTOG grading schema. The cosmetic assessment was performed by the physicians using the controlateral untreated breast as the reference (Harvard scale). Results.- Median patient age was 66 years (range 51-80). Median follow-up was 15 months (range 6-46). Tumor size was 2 cm in 4(6%). The mean value of the ratio between the PTV and the whole ipsilateral breast volume was 38 % and the median percentage whole breast volume that received 95 % of prescribed dose was 34% (range 16%-55%). The rate of G1 and G2 acute skin toxicity was 28% and 2% respectively and the late toxicity was 17% (G1). G2 or greater toxicities were not observed. The most pronounced G1 late toxicity was subcutaneous fibrosis, developed in 3 patients. The cosmetic outcome was excellent in 83% and good in 17%. Conclusion.- Accelerated partial breast irradiation using three-dimensional conformal radiotherapy is technically feasible with very low acute and late toxicity. Long-term results are needed to assess

  19. World-volume effective action of exotic five-brane in M-theory

    International Nuclear Information System (INIS)

    Kimura, Tetsuji; Sasaki, Shin; Yata, Masaya

    2016-01-01

    We study the world-volume effective action of an exotic five-brane, known as the M-theory 5"3-brane (M5"3-brane) in eleven dimensions. The supermultiplet of the world-volume theory is the N=(2,0) tensor multiplet in six dimensions. The world-volume action contains three Killing vectors k̂_I_̂"M (Î=1,2,3) associated with the U(1)"3 isometry. We find the effective T-duality rule for the eleven-dimensional backgrounds that transforms the M5-brane effective action to that of the M5"3-brane. We also show that our action provides the source term for the M5"3-brane geometry in eleven-dimensional supergravity.

  20. Effects of Partial and Acute Total Sleep Deprivation on Performance across Cognitive Domains, Individuals and Circadian Phase

    Science.gov (United States)

    Lo, June C.; Groeger, John A.; Santhi, Nayantara; Arbon, Emma L.; Lazar, Alpar S.; Hasan, Sibah; von Schantz, Malcolm; Archer, Simon N.; Dijk, Derk-Jan

    2012-01-01

    Background Cognitive performance deteriorates during extended wakefulness and circadian phase misalignment, and some individuals are more affected than others. Whether performance is affected similarly across cognitive domains, or whether cognitive processes involving Executive Functions are more sensitive to sleep and circadian misalignment than Alertness and Sustained Attention, is a matter of debate. Methodology/Principal Findings We conducted a 2 × 12-day laboratory protocol to characterize the interaction of repeated partial and acute total sleep deprivation and circadian phase on performance across seven cognitive domains in 36 individuals (18 males; mean ± SD of age = 27.6±4.0 years). The sample was stratified for the rs57875989 polymorphism in PER3, which confers cognitive susceptibility to total sleep deprivation. We observed a deterioration of performance during both repeated partial and acute total sleep deprivation. Furthermore, prior partial sleep deprivation led to poorer cognitive performance in a subsequent total sleep deprivation period, but its effect was modulated by circadian phase such that it was virtually absent in the evening wake maintenance zone, and most prominent during early morning hours. A significant effect of PER3 genotype was observed for Subjective Alertness during partial sleep deprivation and on n-back tasks with a high executive load when assessed in the morning hours during total sleep deprivation after partial sleep loss. Overall, however, Subjective Alertness and Sustained Attention were more affected by both partial and total sleep deprivation than other cognitive domains and tasks including n-back tasks of Working Memory, even when implemented with a high executive load. Conclusions/Significance Sleep loss has a primary effect on Sleepiness and Sustained Attention with much smaller effects on challenging Working Memory tasks. These findings have implications for understanding how sleep debt and circadian rhythmicity

  1. Potential future impact of a partially effective HIV vaccine in a southern African setting

    DEFF Research Database (Denmark)

    Phillips, Andrew N; Cambiano, Valentina; Nakagawa, Fumiyo

    2014-01-01

    of a realistic future implementation scenario in resource limited settings. METHODS: An individual level model of HIV transmission, progression and the effect of antiretroviral therapy was used to predict the outcome to 2060 of introduction in 2025 of a partially effective vaccine with various combinations...

  2. The strategic value of partial vertical integration

    OpenAIRE

    Fiocco, Raffaele

    2014-01-01

    We investigate the strategic incentives for partial vertical integration, namely, partial ownership agreements between manufacturers and retailers, when retailers privately know their costs and engage in differentiated good price competition. The partial misalignment between the profit objectives within a partially integrated manufacturer-retailer hierarchy entails a higher retail price than under full integration. This `information vertical effect' translates into an opposite ...

  3. Effect of partial substitution of dried plantain flour on the sensory and ...

    African Journals Online (AJOL)

    Effect of partial substitution of dried plantain flour on the sensory and functional properties of maize flour based snack ( Kokoro ) ... It is concluded that plantain flour can be successfully blended with maize flour for the production of good kokoro product. Recommendation is made for the large scale production of fortified ...

  4. Marijuana smoking: effects of varying puff volume and breathhold duration.

    Science.gov (United States)

    Azorlosa, J L; Greenwald, M K; Stitzer, M L

    1995-02-01

    Two studies were conducted to quantify biological and behavioral effects resulting from exposure to controlled doses of marijuana smoke. In one study, puff volume (30, 60 and 90 ml) and in a second study, breathhold duration (0, 10 and 20 sec) were systematically varied while holding constant other smoking topography parameters (number of puffs = 10, interpuff interval = 60 sec and inhalation volume = 25% of vital capacity). Each study also varied levels of delta 9-tetrahydro-cannabinol marijuana cigarette content (1.75% and 3.55%). Regular marijuana users served as subjects (n = 7 in each experiment). Subjects smoked 10 puffs in each of six sessions; a seventh, nonsmoking session (all measures recorded at the same times as in active smoking sessions) served as a control. Variations in puff volume produced significant dose-related changes in postsmoking plasma delta 9-tetrahydro-cannabinol levels, carbon monoxide boost and subjective effects (e.g., "high"). In contrast, breathholding for 10 or 20 sec versus 0 sec increased plasma delta 9-tetrahydro-cannabinol levels but not CO boost or subjective effects. Task performance measures were not reliably influenced by marijuana smoke exposure within the dosing ranges examined. These findings confirm the utility of the controlled smoking technology, support the notion that cumulative puff volume systematically influences biological exposure and subjective effects, but cast doubt on the common belief that prolonged breathholding of marijuana smoke enhances classical subjective effects associated with its reinforcing value in humans.

  5. Factors influencing liver and spleen volume changes after donor hepatectomy for living donor liver transplantation

    International Nuclear Information System (INIS)

    Bae, Ji Hee; Ryeom, Hunku; Song, Jung Hup

    2013-01-01

    To define the changes in liver and spleen volumes in the early postoperative period after partial liver donation for living-donor liver transplantation (LDLT) and to determine factors that influence liver and spleen volume changes. 27 donors who underwent partial hepatectomy for LDLT were included in this study. The rates of liver and spleen volume change, measured with CT volumetry, were correlated with several factors. The analyzed factors included the indocyanine green (ICG) retention rate at 15 minutes after ICG administration, preoperative platelet count, preoperative liver and splenic volumes, resected liver volume, resected-to-whole liver volume ratio (LV R /LV W ), resected liver volume to the sum of whole liver and spleen volume ratio [LV R /(LV W + SV 0 )], and pre and post hepatectomy portal venous pressures. In all hepatectomy donors, the volumes of the remnant liver and spleen were increased (increased rates, 59.5 ± 50.5%, 47.9 ± 22.6%). The increment rate of the remnant liver volume revealed a positive correlation with LV R /LV W (r = 0.759, p R /LV W influences the increment rate of the remnant liver volume.

  6. Effect of Mass Transport in the Synthesis of Partially Acetylated Dendrimer: Implications for Functional Ligand–Nanoparticle Distributions

    OpenAIRE

    Mullen, Douglas G.; Borgmeier, Emilee L.; Fang, Ming; McNerny, Daniel Q.; Desai, Ankur; Baker, James R.; Orr, Bradford G.; Holl, Mark M. Banaszak

    2010-01-01

    Partial acetylation of the amine-terminated poly(amidoamine) dendrimer has been used in the preparation of dendrimer particles conjugated with a wide variety of functional ligands including targeting moieties, therapeutic agents, and dye molecules. The effectiveness of mass transport during the partial acetylation reaction was found to have a major effect on subsequent distributions of dendrimer–ligand components and to be a major source of inconsistency between batches. This study has broad ...

  7. Numerical analysis of partially molten splat during thermal spray process using the finite element method

    Science.gov (United States)

    Zirari, M.; Abdellah El-Hadj, A.; Bacha, N.

    2010-03-01

    A finite element method is used to simulate the deposition of the thermal spray coating process. A set of governing equations is solving by a volume of fluid method. For the solidification phenomenon, we use the specific heat method (SHM). We begin by comparing the present model with experimental and numerical model available in the literature. In this study, completely molten or semi-molten aluminum particle impacts a H13 tool steel substrate is considered. Next we investigate the effect of inclination of impact of a partially molten particle on flat substrate. It was found that the melting state of the particle has great effects on the morphologies of the splat.

  8. 76 FR 22414 - Amended Proposed Withdrawal, Notice of Public Meetings, Partial Termination of Segregative Effect...

    Science.gov (United States)

    2011-04-21

    ... Withdrawal, Notice of Public Meetings, Partial Termination of Segregative Effect; Arizona, California... the proposed SEZs to include some additional lands. It also terminates the segregative effect as to... proposal is cancelled and the segregative effect established by the June 30, 2009, Notice of Proposed...

  9. Skew-t partially linear mixed-effects models for AIDS clinical studies.

    Science.gov (United States)

    Lu, Tao

    2016-01-01

    We propose partially linear mixed-effects models with asymmetry and missingness to investigate the relationship between two biomarkers in clinical studies. The proposed models take into account irregular time effects commonly observed in clinical studies under a semiparametric model framework. In addition, commonly assumed symmetric distributions for model errors are substituted by asymmetric distribution to account for skewness. Further, informative missing data mechanism is accounted for. A Bayesian approach is developed to perform parameter estimation simultaneously. The proposed model and method are applied to an AIDS dataset and comparisons with alternative models are performed.

  10. World-volume effective action of exotic five-brane in M-theory

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Tetsuji [Research and Education Center for Natural Sciences, Keio University, Hiyoshi 4-1-1, Yokohama, Kanagawa 223-8521 (Japan); Department of Physics, Tokyo Institute of Technology,Tokyo 152-8551 (Japan); Sasaki, Shin [Department of Physics, Kitasato University,Sagamihara 252-0373 (Japan); Yata, Masaya [Department of Physics, National University of Singapore,2, Science Drive 3, Singapore 117542 (Singapore)

    2016-02-25

    We study the world-volume effective action of an exotic five-brane, known as the M-theory 5{sup 3}-brane (M5{sup 3}-brane) in eleven dimensions. The supermultiplet of the world-volume theory is the N=(2,0) tensor multiplet in six dimensions. The world-volume action contains three Killing vectors k̂{sub Î}{sup M} (Î=1,2,3) associated with the U(1){sup 3} isometry. We find the effective T-duality rule for the eleven-dimensional backgrounds that transforms the M5-brane effective action to that of the M5{sup 3}-brane. We also show that our action provides the source term for the M5{sup 3}-brane geometry in eleven-dimensional supergravity.

  11. Compatriot partiality and cosmopolitan justice: Can we justify compatriot partiality within the cosmopolitan framework?

    Directory of Open Access Journals (Sweden)

    Rachelle Bascara

    2016-10-01

    Full Text Available This paper shows an alternative way in which compatriot partiality could be justified within the framework of global distributive justice. Philosophers who argue that compatriot partiality is similar to racial partiality capture something correct about compatriot partiality. However, the analogy should not lead us to comprehensively reject compatriot partiality. We can justify compatriot partiality on the same grounds that liberation movements and affirmative action have been justified. Hence, given cosmopolitan demands of justice, special consideration for the economic well-being of your nation as a whole is justified if and only if the country it identifies is an oppressed developing nation in an unjust global order.This justification is incomplete. We also need to say why Person A, qua national of Country A, is justified in helping her compatriots in Country A over similarly or slightly more oppressed non-compatriots in Country B. I argue that Person A’s partiality towards her compatriots admits further vindication because it is part of an oppressed group’s project of self-emancipation, which is preferable to paternalistic emancipation.Finally, I identify three benefits in my justification for compatriot partiality. First, I do not offer a blanket justification for all forms of compatriot partiality. Partiality between members of oppressed groups is only a temporary effective measure designed to level an unlevel playing field. Second, because history attests that sovereign republics could arise as a collective response to colonial oppression, justifying compatriot partiality on the grounds that I have identified is conducive to the development of sovereignty and even democracy in poor countries, thereby avoiding problems of infringement that many humanitarian poverty alleviation efforts encounter. Finally, my justification for compatriot partiality complies with the implicit cosmopolitan commitment to the realizability of global justice

  12. Effects of partial replacement of barley with sugar beet pulp on pre ...

    African Journals Online (AJOL)

    Sixteen Zel ewes (BW = 37 ± 3.10 kg) were used in a completely randomized design to determine the effects of partial replacement of barley grain with beet pulp (BP), during late pregnancy and early lactation, on litter weight, lamb's daily gain, milk yield and milk composition. Dietary treatments were initiated approximately ...

  13. Functional analytic methods in complex analysis and applications to partial differential equations

    International Nuclear Information System (INIS)

    Mshimba, A.S.A.; Tutschke, W.

    1990-01-01

    The volume contains 24 lectures given at the Workshop on Functional Analytic Methods in Complex Analysis and Applications to Partial Differential Equations held in Trieste, Italy, between 8-19 February 1988, at the ICTP. A separate abstract was prepared for each of these lectures. Refs and figs

  14. Syngas fermentation to biofuels: Effects of hydrogen partial pressure on hydrogenase efficiency

    International Nuclear Information System (INIS)

    Skidmore, Bradley E.; Baker, Ryan A.; Banjade, Dila R.; Bray, Jason M.; Tree, Douglas R.; Lewis, Randy S.

    2013-01-01

    Producing biofuels from gasified biomass (synthesis gas) via microbial fermentation is currently being pursued as one alternative in biofuels development. In synthesis gas fermentation, reducing equivalents from H 2 oxidation via hydrogenase is important towards directing more carbon towards product formation. In this work, kinetic studies of H 2 utilization via the Clostridium P11 hydrogenase enzyme were performed to determine the most appropriate model to predict hydrogenase activity as a function of H 2 partial pressure. An important aspect of this work included the proper analysis of electron acceptors used in the kinetic studies. The K H 2 model parameter governing the effect of H 2 partial pressure on activity was ∼30 kPa (absolute), independent of the type and concentration of electron acceptor. The K H 2 value indicates that H 2 partial pressures typically associated with syngas fermentation will result in compromised efficiency of the hydrogenase activity. -- Highlights: ► We model hydrogenase activity as a function of H 2 and electron acceptors. ► Model shows the H 2 kinetic parameter is independent of electron acceptor. ► Hydrogenase efficiency is compromised at H 2 levels observed in gasified biomass

  15. The Effect of Stock Return Sequences on Trading Volumes

    Directory of Open Access Journals (Sweden)

    Andrey Kudryavtsev

    2017-10-01

    Full Text Available The present study explores the effect of the gambler’s fallacy on stock trading volumes. I hypothesize that if a stock’s price rises (falls during a number of consecutive trading days, then the gambler’s fallacy may cause at least some of the investors to expect that the stock’s price “has” to subsequently fall (rise, and thus, to increase their willingness to sell (buy the stock, resulting in a stronger degree of disagreement between the investors and a higher-than-usual stock trading volume on the first day when the stock’s price indeed falls (rises. Employing a large sample of daily price and trading volume data, I document that following relatively long sequences of the same-sign stock returns, on the days when the sign is reversed, the trading activity in the respective stocks is abnormally high. Moreover, average abnormal trading volumes gradually and significantly increase with the length of the preceding return sequence. The effect is slightly more pronounced following the sequences of negative stock returns, and remains significant after controlling for other potentially influential factors, including contemporaneous and lagged actual and absolute stock returns, historical stock returns and volatilities, and company-specific events, such as earnings announcements and dividend payments.

  16. The effect of nanocrystallization and free volume on the room temperature plasticity of Zr-based bulk metallic glasses

    International Nuclear Information System (INIS)

    Mondal, K.; Ohkubo, T.; Toyama, T.; Nagai, Y.; Hasegawa, M.; Hono, K.

    2008-01-01

    To understand the mechanism of the room temperature plasticity of bulk metallic glasses (BMGs), microstructure observations, density measurements and positron annihilation studies were carried out for Zr-based BMGs cast at various temperatures and post-annealed under different conditions. We found that higher casting temperatures cause partial crystallization, which enhance the plasticity as long as the volume fraction of the crystalline phase is low. However, a similar nanocrystalline microstructure produced by post-annealing often leads to a large loss of plasticity, while certain conditions enhance the plasticity. Based on density measurements and positron annihilation lifetime spectroscopy, we conclude that the relative contribution of free volume and nanocrystallization is important for acquiring plasticity in metallic glasses

  17. Correlation among body height, intelligence, and brain gray matter volume in healthy children.

    Science.gov (United States)

    Taki, Yasuyuki; Hashizume, Hiroshi; Sassa, Yuko; Takeuchi, Hikaru; Asano, Michiko; Asano, Kohei; Kotozaki, Yuka; Nouchi, Rui; Wu, Kai; Fukuda, Hiroshi; Kawashima, Ryuta

    2012-01-16

    A significant positive correlation between height and intelligence has been demonstrated in children. Additionally, intelligence has been associated with the volume of gray matter in the brains of children. Based on these correlations, we analyzed the correlation among height, full-scale intelligence quotient (IQ) and gray matter volume applying voxel-based morphometry using data from the brain magnetic resonance images of 160 healthy children aged 5-18 years of age. As a result, body height was significantly positively correlated with brain gray matter volume. Additionally, the regional gray matter volume of several regions such as the bilateral prefrontal cortices, temporoparietal region, and cerebellum was significantly positively correlated with body height and that the gray matter volume of several of these regions was also significantly positively correlated with full-scale intelligence quotient (IQ) scores after adjusting for age, sex, and socioeconomic status. Our results demonstrate that gray and white matter volume may mediate the correlation between body height and intelligence in healthy children. Additionally, the correlations among gray and white matter volume, height, and intelligence may be at least partially explained by the effect of insulin-like growth factor-1 and growth hormones. Given the importance of the effect of environmental factors, especially nutrition, on height, IQ, and gray matter volume, the present results stress the importance of nutrition during childhood for the healthy maturation of body and brain. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Exploring point-cloud features from partial body views for gender classification

    Science.gov (United States)

    Fouts, Aaron; McCoppin, Ryan; Rizki, Mateen; Tamburino, Louis; Mendoza-Schrock, Olga

    2012-06-01

    In this paper we extend a previous exploration of histogram features extracted from 3D point cloud images of human subjects for gender discrimination. Feature extraction used a collection of concentric cylinders to define volumes for counting 3D points. The histogram features are characterized by a rotational axis and a selected set of volumes derived from the concentric cylinders. The point cloud images are drawn from the CAESAR anthropometric database provided by the Air Force Research Laboratory (AFRL) Human Effectiveness Directorate and SAE International. This database contains approximately 4400 high resolution LIDAR whole body scans of carefully posed human subjects. Success from our previous investigation was based on extracting features from full body coverage which required integration of multiple camera images. With the full body coverage, the central vertical body axis and orientation are readily obtainable; however, this is not the case with a one camera view providing less than one half body coverage. Assuming that the subjects are upright, we need to determine or estimate the position of the vertical axis and the orientation of the body about this axis relative to the camera. In past experiments the vertical axis was located through the center of mass of torso points projected on the ground plane and the body orientation derived using principle component analysis. In a natural extension of our previous work to partial body views, the absence of rotational invariance about the cylindrical axis greatly increases the difficulty for gender classification. Even the problem of estimating the axis is no longer simple. We describe some simple feasibility experiments that use partial image histograms. Here, the cylindrical axis is assumed to be known. We also discuss experiments with full body images that explore the sensitivity of classification accuracy relative to displacements of the cylindrical axis. Our initial results provide the basis for further

  19. Cognitive and psychosocial effects of oxcarbazepine monotherapy in newly diagnosed partial epilepsy.

    Science.gov (United States)

    Kim, Daeyoung; Seo, Ji-Hye; Joo, Eun Yeon; Lee, Hyang Woon; Shin, Won Chul; Hong, Seung Bong

    2014-01-01

    The aim of this study was to assess the effects of oxcarbazepine (OXC) on cognition and psychosocial difficulties in patients with new-onset partial epilepsy. Cognitive and psychosocial assessments were performed before and after 6 to 12 months of OXC monotherapy in 52 drug-naive patients (25 women; mean age, 31.1 years; SD, 12.1 years). Cognitive functions were evaluated with well-structured and validated tools. Mood, psychological distress, subjective handicap, and quality of life were also evaluated. Differences between baseline and after-treatment evaluation were compared and adjusted for possible confounders such as age, sex, seizure control, duration of epilepsy, assessment interval, and epileptogenic region. Mean assessment interval was 231.8 (range, 182-348) days, and mean (SD) OXC dose at retest was 693.8 (208.9) mg. The OXC was found to have no significant adverse effect on cognition. Furthermore, OXC monotherapy was not found to affect psychosocial difficulties, including psychological distress and subjective handicap. The results suggest that OXC monotherapy could be used to treat newly diagnosed partial epilepsy without adversely affecting cognitive and psychosocial functions.

  20. Quark-mixing renormalization effects on the W-boson partial decay widths

    International Nuclear Information System (INIS)

    Almasy, A.A.; Kniehl, B.A.; Sirlin, A.

    2008-10-01

    We briefly review existing proposals for the renormalization of the Cabibbo- Kobayashi-Maskawa matrix and study their numerical effects on the W-boson partial decay widths. The differences between the decay widths predicted by the various renormalization schemes are generally negligible, while their deviations from the MS results are very small, except for W + → u anti b and W + →c anti b, where they reach approximately 4%. (orig.)

  1. Method of phase-Doppler anemometry free from the measurement-volume effect.

    Science.gov (United States)

    Qiu, H; Hsu, C T

    1999-05-01

    A novel method is developed to improve the accuracy of particle sizing in laser phase-Doppler anemometry (PDA). In this method the vector sum of refractive and reflective rays is taken into consideration in describing a dual-mechanism-scattering model caused by a nonuniformly illuminated PDA measurement volume. The constraint of the single-mechanism-scattering model in the conventional PDA is removed. As a result the error caused by the measurement-volume effect, which consists of a Gaussian-beam defect and a slit effect, can be eliminated. This new method can be easily implemented with minimal modification of the conventional PDA system. The results of simulation based on the generalized Lorenz-Mie theory show that the new method can provide a PDA system free from the measurement-volume effect.

  2. Effect of Gamma Radiation sterilization versus Disinfection on Removable Partial Dentures (Microbiological study)

    International Nuclear Information System (INIS)

    Mohammed, M.A.

    2011-01-01

    The aim of the study was to compare between the effectiveness of disinfection, using commercially available Fittydent super cleansing tablets versus sterilization, using gamma radiation on candidal growth in maxillary removable partial dentures. Methods: Fourteen partially edentulous subjects were selected according to specific criteria and divided equally and randomly into two groups; Group I: disinfection group and Group II: sterilization group. Conventional maxillary removable partial dentures were constructed for all subjects. The swab technique was used to collect the samples one month after denture delivery, immediately after disinfection/sterilization, and then one week, two weeks, three weeks, four weeks, and five weeks after disinfection/sterilization respectively. Bacteriological candidal colony count was performed using a manual contact colony counter. Results: Both methods (disinfection and sterilization) led to a noticeable decrease in the candidal count. However this decrease was highly and markedly evident in Group II as compared to Group I. Infact, no candidal growth was recorded for group II immediately after strerilization and was maintained for two more weeks. Statistical analysis revealed highly significant differences between the two groups. Conclusions: Both methods were effective in decreasing the number of Candida albicans adhering to the denture. However, sterilization using Gamma radiation had a more superior immediate, as well as, long term efficiency as compared to disinfection using Fittydent super cleansing tablets.

  3. Metabolic impact of partial volume correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment.

    Science.gov (United States)

    Stefano, A; Gallivanone, F; Messa, C; Gilardi, M C; Gastiglioni, I

    2014-12-01

    The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated for each lesion, with and without PVC. The accuracy, reproducibility, clinical feasibility and the metabolic impact on treatment response of the considered PVC method was evaluated. The PVC method was found clinically feasible in bone lesions, with an accuracy of 93% for lesion sphere-equivalent diameter >1 cm. Applying PVC, average SUV values increased, from 7% up to 154% considering both PET-I and PET-II studies, proving the need of the correction. As main finding, PVC modified the therapy response classification in 6 cases according to EORTC 1999 classification and in 5 cases according to PERCIST 1.0 classification. PVC has an important metabolic impact on the assessment of tumor response to treatment by [18F]FDG PET-CT oncological studies.

  4. ANTIANDROGENIC EFFECTS OF VINCLOZOLIN ON MALE RATS ARE PARTIALLY ATTENUATED BY TESTOSTERONE PROPIONATE

    Science.gov (United States)

    ANTIANDROGENIC EFFECTS OF VINCLOZOLIN ON MALE RATS ARE PARTIALLY ATTENUATED BY TESTOSTERONE PROPIONATECynthia Wolf1,2 , Joe Ostby1, Jonathan Furr 1, Gerald A. LeBlanc2, and L. Earl Gray, Jr.11 US Environmental Protection Agency, NHEERL, RTD, RTP, NC 27711, 2 Departmen...

  5. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Schantz, Daryl I. [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); University of Manitoba, Variety Children' s Heart Centre, Winnipeg, MB (Canada); Dragulescu, Andreea [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); Memauri, Brett [University of Manitoba, Department of Radiology, St. Boniface General Hospital, Winnipeg, MB (Canada); Grotenhuis, Heynric B. [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); Wilhelmina Children' s Hospital, Utrecht (Netherlands); Seed, Mike; Grosse-Wortmann, Lars [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada)

    2016-10-15

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (P<0.001), and left atrial volumes increased 10.0%, from 50.0 to 55.0 ml/m2 (P<0.001). Right ventricular volumes increased 6.0%, from 91.1 to 96.5 ml/m2 (P<0.001), and left ventricular volumes increased 3.2%, from 87.0 to 89.8 ml/m2 (P<0.001). Hydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a ''variable'' that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient. (orig.)

  6. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers

    International Nuclear Information System (INIS)

    Schantz, Daryl I.; Dragulescu, Andreea; Memauri, Brett; Grotenhuis, Heynric B.; Seed, Mike; Grosse-Wortmann, Lars

    2016-01-01

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (P<0.001), and left atrial volumes increased 10.0%, from 50.0 to 55.0 ml/m2 (P<0.001). Right ventricular volumes increased 6.0%, from 91.1 to 96.5 ml/m2 (P<0.001), and left ventricular volumes increased 3.2%, from 87.0 to 89.8 ml/m2 (P<0.001). Hydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a ''variable'' that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient. (orig.)

  7. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers.

    Science.gov (United States)

    Schantz, Daryl I; Dragulescu, Andreea; Memauri, Brett; Grotenhuis, Heynric B; Seed, Mike; Grosse-Wortmann, Lars

    2016-10-01

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (PHydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a "variable" that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient.

  8. Interventions for replacing missing teeth: partially absent dentition.

    Science.gov (United States)

    Abt, Elliot; Carr, Alan B; Worthington, Helen V

    2012-02-15

    Management of individuals presenting with partial loss of teeth is a common task for dentists. Outcomes important to the management of missing teeth in the partially absent dentition should be systematically summarized. This review recognizes both the challenges associated with such a summarization and the critical nature of the information for patients. To assess the effects of different prostheses for the treatment of partially absent dentition in terms of the following outcomes: long-term success, function, morbidity and patient satisfaction. We searched the Cochrane Oral Health Group's Trials Register (to 21 March 2011), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2011, Issue 1), MEDLINE via OVID (1950 to March 2011) and EMBASE via OVID (1980 to March 2011). There were no restrictions regarding language or date of publication. We contacted several authors to identify non-published trials. Randomized controlled trials (RCTs) comparing different methods (including the design and materials used) of treating partial edentulism, with clinically relevant outcomes, were included in this review. Trials reporting only surrogate outcomes, such as plaque accumulation or gingival volume, were excluded from this review. Two review authors independently carried out the screening of eligible studies, assessment of dimensions of quality of trials, and data extraction. Results were expressed as mean differences for continuous data, risk ratios for dichotomous outcomes, and hazard ratios with 95% confidence intervals for time-to-event data. Twenty-one trials met the inclusion criteria for this review. Twenty-four per cent of these were assessed as being at high risk of bias and the remainder were at unclear risk of bias. The clinical heterogeneity among the included studies precluded any attempt at meta-analysis. There was insufficient evidence to determine whether one type of removable dental prosthesis (RDP) was better or worse than

  9. Pressure effects on the structure, kinetic, and thermodynamic properties of heat-induced aggregation of protein studied by FT-IR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Y [Applied Chemistry Department, Ritsumeikan University, Kusatsu, Shiga 525-8577 (Japan); Okuno, A [Research Department 3, Central Research, Bridgestone Co. Kodaira, Tokyo 187-8531 (Japan); Kato, M, E-mail: taniguti@sk.ritsumei.ac.j [Pharmaceutical Sciences Department, Ritsumeikan University, Kusatsu, Shiga 525-8577 (Japan)

    2010-03-01

    Pressure can retrain the heat-induced aggregation and dissociate the heat-induced aggregates. We observed the aggregation-preventing pressure effect and the aggregates-dissociating pressure effect to characterize the heat-induced aggregation of equine serum albumin (ESA) by FT-IR spectroscopy. The results suggest the {alpha}-helical structure collapses at the beginning of heat-induced aggregation through the swollen structure, and then the rearrangement of structure to the intermolecular {beta}-sheet takes place through partially unfolded structure. We determined the activation volume for the heat-induced aggregation ({Delta}V'' = +93 ml/mol) and the partial molar volume difference between native state and heat-induced aggregates ({Delta}V=+32 ml/mol). This positive partial molar volume difference suggests that the heat-induced aggregates have larger internal voids than the native structure. Moreover, the positive volume change implies that the formation of the intermolecular {beta}-sheet is unfavorable under high pressure.

  10. Higher Adolescent Body Mass Index is Associated with Lower Regional Gray and White Matter Volumes and Lower Levels of Positive Emotionality

    Directory of Open Access Journals (Sweden)

    James T Kennedy

    2016-09-01

    Full Text Available Adolescent obesity is associated with an increased chance of developing serious health risks later in life. Identifying the neurobiological and personality factors related to increases in adiposity is important to understanding what drives maladaptive consummatory and exercise behaviors that result in obesity. Previous research has largely focused on adults with few findings published on interactions among adiposity, brain structure, and personality. In this study, Voxel Based Morphometry (VBM was used to identify associations between gray and white matter volumes and increasing adiposity, as measured by Body Mass Index percentile (BMI%, in 137 adolescents (age range: 9-20 years, Body Mass Index percentile range: 5.16-99.56. Variations in gray and white matter volume and BMI% were then linked to individual differences in personality measures from the Multidimensional Personality Questionnaire (MPQ. After controlling for age and other covariates, BMI% correlated negatively with gray matter volume in the bilateral caudate (right: partial r = -0.338, left: r -0.404, medial prefrontal cortex (partial r = -0.339, anterior cingulate (partial r = -0.312, bilateral frontal pole (right: partial r = -0.368, left: r= -0.316, and uncus (partial r = -0.475 as well as white matter volume bilaterally in the anterior limb of the internal capsule (right: partial r = -0.34, left: r = -0.386, extending to the left middle frontal subgyral white matter. Agentic Positive Emotionality (PEM-AG was correlated negatively with BMI% (partial r = -0.384. PEM-AG was correlated positively with gray matter volume in the right uncus (partial r = 0.329. These results suggest that higher levels of adiposity in adolescents are associated with lower trait levels in reward-related personality domains, as well as structural variations in brain regions associated with reward processing, control, and sensory integration.

  11. Methods for improving mechanical properties of partially stabilized zirconia and the resulting product

    International Nuclear Information System (INIS)

    Aronov, V.A.

    1987-01-01

    A method for improving mechanical surface properties of a rigid body comprising partially stabilized zirconia as a constituent is described comprising the following steps: (i) providing a rigid body having an exposed surface and an interior volume; (ii) subjecting the exposed surface region of partially stabilized zirconia to external heating to heat the exposed surface region to 1100 0 C-1600 0 C without heating the interior volume above 500 0 C-800 0 C; and (iii) cooling the rigid body to a temperature of less than 500 0 C to cause a portion of the exposed surface region to transform from the tetragonal lattice modification to the monoclinic lattice modification, thereby creating a compressive stress field in the exposed surface region and improving the mechanical surface properties of the exposed surface region. In a ceramic body comprising a first exposed region of a partially stabilized zirconia, and a second region of a partially stabilized zirconia at an interior portion of the ceramic body, the improvement is described comprising the ceramic body having in the first, exposed region a greater percentage of the monoclinic lattice modification than in the second region; having in the first, exposed region 5 percent to 100 percent in the monoclinic lattice modification; and having a molded surface finish in the first, exposed region; the first, exposed region being subjected to a compressive field resulting from the greater percentage of the monoclinic lattice modification

  12. Confining dyon gas with finite-volume effects under control

    Energy Technology Data Exchange (ETDEWEB)

    Bruckmann, Falk [Regensburg Univ. (Germany). Institut fuer Theoretische Physik; Dinter, Simon [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik; Ilgenfritz, Ernst-Michael [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik; Joint Institute for Nuclear Research, VBLHEP, Dubna (Russian Federation); Maier, Benjamin; Mueller-Preussker, Michael [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik; Wagner, Marc [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik; Frankfurt Univ. (Germany). Inst. fuer Theoretische Physik

    2011-11-15

    As an approach to describe the long-range properties of non-Abelian gauge theories at non-zero temperature Tvolume effects. Therefore, we demonstrate the application of Ewald's summation method to this system. Finite-volume effects are shown to be under control, which is a crucial requirement for numerical studies of interacting dyon ensembles. (orig.)

  13. Confining dyon gas with finite-volume effects under control

    International Nuclear Information System (INIS)

    Bruckmann, Falk; Maier, Benjamin; Mueller-Preussker, Michael; Wagner, Marc; Frankfurt Univ.

    2011-11-01

    As an approach to describe the long-range properties of non-Abelian gauge theories at non-zero temperature T c , we consider a non-interacting ensemble of dyons (magnetic monopoles) with non-trivial holonomy. We show analytically, that the quark-antiquark free energy from the Polyakov loop correlator grows linearly with the distance, and how the string tension scales with the dyon density. In numerical treatments, the long-range tails of the dyon fields cause severe finite-volume effects. Therefore, we demonstrate the application of Ewald's summation method to this system. Finite-volume effects are shown to be under control, which is a crucial requirement for numerical studies of interacting dyon ensembles. (orig.)

  14. Molar volume and adsorption isotherm dependence of capillary forces in nanoasperity contacts.

    Science.gov (United States)

    Asay, David B; Kim, Seong H

    2007-11-20

    The magnitude of the capillary force at any given temperature and adsorbate partial pressure depends primarily on four factors: the surface tension of the adsorbate, its liquid molar volume, its isothermal behavior, and the contact geometry. At large contacting radii, the adsorbate surface tension and the contact geometry are dominating. This is the case of surface force apparatus measurements and atomic force microscopy (AFM) experiments with micrometer-size spheres. However, as the size of contacting asperities decreases to the nanoscale as in AFM experiments with sharp tips, the molar volume and isotherm of the adsorbate become very important to capillary formation as well as capillary adhesion. This effect is experimentally and theoretically explored with simple alcohol molecules (ethanol, 1-butanol, and 1-pentanol) which have comparable surface tensions but differing liquid molar volumes. Adsorption isotherms for these alcohols on silicon oxide are also reported.

  15. Melt migration modeling in partially molten upper mantle

    Science.gov (United States)

    Ghods, Abdolreza

    The objective of this thesis is to investigate the importance of melt migration in shaping major characteristics of geological features associated with the partial melting of the upper mantle, such as sea-floor spreading, continental flood basalts and rifting. The partial melting produces permeable partially molten rocks and a buoyant low viscosity melt. Melt migrates through the partially molten rocks, and transfers mass and heat. Due to its much faster velocity and appreciable buoyancy, melt migration has the potential to modify dynamics of the upwelling partially molten plumes. I develop a 2-D, two-phase flow model and apply it to investigate effects of melt migration on the dynamics and melt generation of upwelling mantle plumes and focusing of melt migration beneath mid-ocean ridges. Melt migration changes distribution of the melt-retention buoyancy force and therefore affects the dynamics of the upwelling plume. This is investigated by modeling a plume with a constant initial melt of 10% where no further melting is considered. Melt migration polarizes melt-retention buoyancy force into high and low melt fraction regions at the top and bottom portions of the plume and therefore results in formation of a more slender and faster upwelling plume. Allowing the plume to melt as it ascends through the upper mantle also produces a slender and faster plume. It is shown that melt produced by decompressional melting of the plume migrates to the upper horizons of the plume, increases the upwelling velocity and thus, the volume of melt generated by the plume. Melt migration produces a plume which lacks the mushroom shape observed for the plume models without melt migration. Melt migration forms a high melt fraction layer beneath the sloping base of the impermeable oceanic lithosphere. Using realistic conditions of melting, freezing and melt extraction, I examine whether the high melt fraction layer is able to focus melt from a wide partial melting zone to a narrow region

  16. Effect of volume and surface charges on discharge structure of glow dielectric barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Shao-Wei; He, Feng; Wang, Yu; Li, Lulu; Ouyang, Ji-Ting [School of Physics, Beijing Institute of Technology, Beijing 100081 (China)

    2013-08-15

    The effect of volume and surface charges on the structure of glow dielectric barrier discharge (DBD) has been investigated numerically by using two-dimensional (2D) fluid modeling. The local increase of volume or surface charges induces a kind of activation-inhibition effect, which enhances the local volume discharge and inhibits the discharge in neighborhoods, resulting in non-uniform discharge. The activation-inhibition effect due to the non-uniform volume and/or surface charges depends on the non-uniformity itself and the applied voltage. The activation-inhibition of non-uniform charges has different effects on the volume charges and the accumulated surface charges. The distribution of remaining free charges (seed electrons) in volume at the beginning of voltage pulse plays a key role for the glow DBD structure, resulting in a patterned DBD, when the seed electrons are non-uniform at higher frequency and moderate voltage or uniform DBD, when the seed electrons are uniform at lower frequency or high voltage. The distribution of surface charges is not the determining factor but a result of the formed DBD structure.

  17. Toxicity and cosmetic outcome of three-dimensional conformal radiotherapy for accelerated partial breast irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gatti, M.; Bresciani, S.; Ponzone, R.; Panaia, R.; Salatino, A.; Stasi, M.; Gabriele, P. [IRCC, Candiolo (Italy)

    2011-10-15

    Full text of publication follows: Purpose.- To analyse the incidence and severity of acute and late normal tissue toxicity and cosmetic outcome using three - dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Patients and Methods.- 70 patients with stage I disease were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation, in an approved protocol. The prescribed dose was 34 Gy in all patients delivered in 10 fractions over 5 consecutive days. On all CT scans gross tumor volume (GTV ) was defined around surgical clips. A 1.5 cm margin was added in order to account for clinical target volume (CTV) . A margin of 1 cm was added to CTI to define the planning target volume (PTV). The dose-volume constraints were followed in accordance with the specifications as dictated in the NSABP/RTOG protocol. After treatment, patients underwent a clinical and cosmetic evaluation every 3 months. Late toxicity was evaluated according to the RTOG grading schema. The cosmetic assessment was performed by the physicians using the controlateral untreated breast as the reference (Harvard scale). Results.- Median patient age was 66 years (range 51-80). Median follow-up was 15 months (range 6-46). Tumor size was < 10 mm in 33 patients (53%) and > 2 cm in 4(6%). The mean value of the ratio between the PTV and the whole ipsilateral breast volume was 38 % and the median percentage whole breast volume that received 95 % of prescribed dose was 34% (range 16%-55%). The rate of G1 and G2 acute skin toxicity was 28% and 2% respectively and the late toxicity was 17% (G1). G2 or greater toxicities were not observed. The most pronounced G1 late toxicity was subcutaneous fibrosis, developed in 3 patients. The cosmetic outcome was excellent in 83% and good in 17%. Conclusion.- Accelerated partial breast irradiation using three-dimensional conformal radiotherapy is technically feasible with very low acute and late toxicity. Long

  18. Health effects of mineral dusts, Volume 28: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Guthrie, G.D. Jr. [ed.] [Los Alamos National Lab., NM (United States); Mossman, B.T. [ed.] [Vermont Univ., Burlington, VT (United States). Dept. of Pathology

    1993-12-31

    The processes that lead to the development of disease (or pathogenesis) by minerals very likely occur at or near the mineral-fluid interface. Thus the field of ``mineral-induced pathogenesis`` is a prime candidate for interdisciplinary research, involving mineral scientists, health scientists, petrologists, pathologists, geochemists, biochemists, and surface scientists, to name a few. This review volume and the short course upon which it was based are intended to provide some of the necessary tools for the researcher interested in this area of interdisciplinary research. The chapters present several of the important problems, concepts, and approaches from both the geological and biological ends of the spectrum. These two extremes are partially integrated throughout the book by cross-referencing between chapters. Chapter 1 also presents a general introduction into the ways in which these two areas overlap. The final chapter of this book discusses some of the regulatory aspects of minerals. A glossary is included at the end of this book, because the complexity of scientific terms in the two fields can thwart even the most enthusiastic of individuals. Individual reports have been processed separately for the database.

  19. Oxygen partial pressure effects on the RF sputtered p-type NiO hydrogen gas sensors

    Science.gov (United States)

    Turgut, Erdal; Çoban, Ömer; Sarıtaş, Sevda; Tüzemen, Sebahattin; Yıldırım, Muhammet; Gür, Emre

    2018-03-01

    NiO thin films were grown by Radio Frequency (RF) Magnetron Sputtering method under different oxygen partial pressures, which are 0.6 mTorr, 1.3 mTorr and 2.0 mTorr. The effects of oxygen partial pressures on the thin films were analyzed through Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), X-ray Diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS) and Hall measurements. The change in the surface morphology of the thin films has been observed with the SEM and AFM measurements. While nano-pyramids have been obtained on the thin film grown at the lowest oxygen partial pressure, the spherical granules lower than 60 nm in size has been observed for the samples grown at higher oxygen partial pressures. The shift in the dominant XRD peak is realized to the lower two theta angle with increasing the oxygen partial pressures. XPS measurements showed that the Ni2p peak involves satellite peaks and two oxidation states of Ni, Ni2+ and Ni3+, have been existed together with the corresponding splitting in O1s spectrum. P-type conductivity of the grown NiO thin films are confirmed by the Hall measurements with concentrations on the order of 1013 holes/cm-3. Gas sensor measurements revealed minimum of 10% response to the 10 ppm H2 level. Enhanced responsivity of the gas sensor devices of NiO thin films is shown as the oxygen partial pressure increases.

  20. Liquid flow rate effects during partial evaporation in a falling film micro contactor

    NARCIS (Netherlands)

    Moschou, P.; Croon, de M.H.J.M.; Schaaf, van der J.; Schouten, J.C.

    2013-01-01

    The focus of this study is the investigation of the effect of liquid flow rate on partial evaporation, enhanced by convective nitrogen flow, in a falling film micro contactor. Experiments are performed at different flow rates and for a certain heating liquid temperature. The temperatures of the gas

  1. Lattice study of finite volume effect in HVP for muon g-2

    Directory of Open Access Journals (Sweden)

    Izubuchi Taku

    2018-01-01

    Full Text Available We study the finite volume effect of the hadronic vacuum polarization contribution to muon g-2, aμhvp,in lattice QCD by comparison with two different volumes, L4 = (5.44 and (8.14 fm4, at physical pion. We perform the lattice computation of highly precise vector-vector current correlator with optimized AMA technique on Nf = 2 + 1 PACS gauge configurations in Wilson-clover fermion and stout smeared gluon action at one lattice cut-off, a−1 = 2.33 GeV. We compare two integrals of aμhvp, momentum integral and time-slice summation, on the lattice and numerically show that the different size of finite volume effect appears between two methods. We also discuss the effect of backward-state propagation into the result of aμhvp with the different boundary condition. Our model-independent study suggest that the lattice computation at physical pion is important for correct estimate of finite volume and other lattice systematics in aμhvp.

  2. Lattice study of finite volume effect in HVP for muon g-2

    Science.gov (United States)

    Izubuchi, Taku; Kuramashi, Yoshinobu; Lehner, Christoph; Shintani, Eigo

    2018-03-01

    We study the finite volume effect of the hadronic vacuum polarization contribution to muon g-2, aμhvp, in lattice QCD by comparison with two different volumes, L4 = (5.4)4 and (8.1)4 fm4, at physical pion. We perform the lattice computation of highly precise vector-vector current correlator with optimized AMA technique on Nf = 2 + 1 PACS gauge configurations in Wilson-clover fermion and stout smeared gluon action at one lattice cut-off, a-1 = 2.33 GeV. We compare two integrals of aμhvp, momentum integral and time-slice summation, on the lattice and numerically show that the different size of finite volume effect appears between two methods. We also discuss the effect of backward-state propagation into the result of aμhvp with the different boundary condition. Our model-independent study suggest that the lattice computation at physical pion is important for correct estimate of finite volume and other lattice systematics in aμhvp.

  3. The volume-expanding effects of autologous liquid stored plasma following hemorrhage

    DEFF Research Database (Denmark)

    Bentzer, Peter; Thomas, Owain D; Westborg, Johan

    2012-01-01

    of plasma transfusion on plasma volume. We report a prospective interventional study in which the plasma volume-expanding effect of autologous plasma was investigated after a controlled hemorrhage. Methods. Plasma obtained by plasmapheresis from nine healthy regular blood donors was stored at 2-6°C. Five...

  4. Cross-correlations in volume space: Differences between buy and sell volumes

    Science.gov (United States)

    Lee, Sun Young; Hwang, Dong Il; Kim, Min Jae; Koh, In Gyu; Kim, Soo Yong

    2011-03-01

    We study the cross-correlations of buy and sell volumes on the Korean stock market in high frequency. We observe that the pulling effects of volumes are as small as that of returns. The properties of the correlations of buy and sell volumes differ. They are explained by the degree of synchronization of stock volumes. Further, the pulling effects on the minimal spanning tree are studied. In minimal spanning trees with directed links, the large pulling effects are clustered at the center, not uniformly distributed. The Epps effect of buy and sell volumes are observed. The reversal of the cross-correlations of buy and sell volumes is also detected.

  5. Total and Partial Computation in Categorical Quantum Foundations

    Directory of Open Access Journals (Sweden)

    Kenta Cho

    2015-11-01

    Full Text Available This paper uncovers the fundamental relationship between total and partial computation in the form of an equivalence of certain categories. This equivalence involves on the one hand effectuses, which are categories for total computation, introduced by Jacobs for the study of quantum/effect logic. On the other hand, it involves what we call FinPACs with effects; they are finitely partially additive categories equipped with effect algebra structures, serving as categories for partial computation. It turns out that the Kleisli category of the lift monad (-+1 on an effectus is always a FinPAC with effects, and this construction gives rise to the equivalence. Additionally, state-and-effect triangles over FinPACs with effects are presented.

  6. Densities, molar volumes, and isobaric expansivities of (d-xylose+hydrochloric acid+water) systems

    International Nuclear Information System (INIS)

    Zhang Qiufen; Yan Zhenning; Wang Jianji; Zhang Hucheng

    2006-01-01

    Densities of (d-xylose+HCl+water) have been measured at temperature in the range (278.15 to 318.15) K as a function of concentration of both d-xylose and hydrochloric acid. The densities have been used to estimate the molar volumes and isobaric expansivity of the ternary solutions. The molar volumes of the ternary solutions vary linearly with mole fraction of d-xylose. The standard partial molar volumes V 2,φ - bar for d-xylose in aqueous solutions of molality (0.2, 0.4, 0.7, 1.1, 1.6, and 2.1) mol.kg -1 HCl have been determined. In the investigated temperature range, the relation: V 2,φ - bar =c 1 +c 2 {(T/K)-273.15} 1/2 , can be used to describe the temperature dependence of the standard partial molar volumes. These results have, in conjunction with the results obtained in water, been used to deduce the standard volumes of transfer, Δ t V - bar , of d-xylose from water to aqueous HCl solutions. An increase in the transfer volume of d-xylose with increasing HCl concentrations has been explained by the stronger interactions of H + with the hydrophilic groups of d-xylose

  7. Influence of dosing volume on the neurotoxicity of bifenthrin.

    Science.gov (United States)

    Wolansky, M J; McDaniel, K L; Moser, V C; Crofton, K M

    2007-01-01

    Pyrethroids are pesticides with high insecticidal activity and relatively low potency in mammals. The influence of dosing volume on the neurobehavioral syndrome following oral acute exposure to the Type-I pyrethroid insecticide bifenthrin in corn oil was evaluated in adult male Long Evans rats. We tested bifenthrin effects at 1 and 5 ml/kg, two commonly used dose volumes in toxicological studies. Two testing times (4 and 7 h) were used in motor activity and functional observational battery (FOB) assessments. Four to eight doses were examined at either dosing condition (up to 20 or 26 mg/kg, at 1 and 5 ml/kg, respectively). Acute oral bifenthrin exposure produced toxic signs typical of Type I pyrethroids, with dose-related increases in fine tremor, decreased motor activity and grip strength, and increased pawing, head shaking, click response, and body temperature. Bifenthrin effects on motor activity and pyrethroid-specific clinical signs were approximately 2-fold more potent at 1 ml/kg than 5 ml/kg. This difference was clearly evident at 4 h and slightly attenuated at 7 h post-dosing. Benchmark dose (BMD) modeling estimated similar 2-fold potency differences in motor activity and pyrethroid-specific FOB data. These findings demonstrate that dose volume, in studies using corn oil as the vehicle influences bifenthrin potency. Further, these data suggest that inconsistent estimates of pyrethroid potency between laboratories are at least partially due to differences in dosing volume.

  8. PENGARUH JUMLAH ANGGOTA, VOLUME USAHA DAN LIKUIDITAS KOPERASI TERHADAP PERMINTAAN JASA AUDIT

    Directory of Open Access Journals (Sweden)

    Nanik Sri Utaminingsih

    2012-03-01

    Full Text Available Kebutuhan akan laporan keuangan yang bisa dipercaya sangatlah penting untuk mengambil keputusan. Permasalahan dari penelitian ini adalah apakah jumlah anggota, volume bisnis dan likuiditas secara parsial dan simultan mempengaruhi permintaan jasa audit. Populasi dalam penelitian ini adalah 765 koperasi dan sampelnya berjumlah 89 koperasi. Data yang digunakan adalah laporan keuangan koperasi pada tahun fiscal 2008. Data analisis yang digunakan adalah analisis deskriptif, multikolnearitas and logistic regression. Kesimpulan dari penelitian ini adalah variabel jumlah anggota dan likuiditas mempengaruhi permintaan jasa audit secara parsial sedangkan volume bisnis tidak mempengaruhi permintaan jasa audit. Secara simultan 3 variabel mempengaruhi permintaan jasa audit. The need for reliable financial statements, and can be trusted is necessary in making a decision. The problem in this study is whether which the number of members, the business volume and liquidity partially and simultaneously affect the demand for audit services. The population in this study were 765 cooperatives and the research sample is 89 cooperatives. The dependent variables in this study are demand audit services. While the independent variables are the number of members, the business vo-lume and liquidity of cooperatives. The data used in the form of cooperative financial reports, fiscal year 2008  with using descriptive analysis, multicolonearitas and logistic regression. The conclusion of this research is variable number of members, and liquidity, the partial affect on demand for audit services, while business volume is partially not influence the audit services. Simultaneously, the three indepen-dent variables influenced the demand for audit services.

  9. Multi-channel 1-to-2 transition amplitudes in a finite volume

    Energy Technology Data Exchange (ETDEWEB)

    Briceno, Raul [JLAB; Hansen, Maxwell [Helmholtz Institute Mainz; Walker-Loud, Andre P [W& M. JLAB

    2015-04-01

    We derive a model-independent expression for finite-volume matrix elements. Specifically, we present a relativistic, non-perturbative analysis of the matrix element of an external current between a one-scalar in-state and a two-scalar out-state. Our result, which is valid for energies below higher-particle inelastic thresholds, generalizes the Lellouch-Luscher formula in two ways: we allow the external current to inject arbitrary momentum into the system and we allow for the final state to be composed an arbitrary number of strongly coupled two-particle states with arbitrary partial waves (including partial-wave mixing induced by the volume). We also illustrate how our general result can be applied to some key examples, such as heavy meson decays and meson photo production. Finally, we point out complications that arise involving unstable resonance states, such as B to K*+l+l when staggered or mixed-action/partially-quenched calculations are performed.

  10. Clinical effectiveness, quality of life and cost-effectiveness of Flaminal® versus Flamazine® in the treatment of partial thickness burns: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Rashaan, Zjir M; Krijnen, Pieta; van den Akker-van Marle, M Elske; van Baar, Margriet E; Vloemans, Adrianus F P; Dokter, Jan; Tempelman, Fenike R H; van der Vlies, Cees H; Breederveld, Roelf S

    2016-03-05

    Partial thickness burns are painful, difficult to manage and can have a negative effect on quality of life through scarring, permanent disfigurement and loss of function. The aim of burn treatment in partial thickness burns is to save lives, stimulate wound healing by creating an optimumly moist wound environment, to have debriding and analgesic effects, protect the wound from infection and be convenient for the patient and caregivers. However, there is no consensus on the optimal treatment of partial thickness wounds. Flaminal® and Flamazine® are two standard treatment options that provide the above mentioned properties in burn treatment. Nevertheless, no randomized controlled study has yet compared these two common treatment modalities in partial thickness burns. Thus, the aim of this study is to evaluate the clinical effectiveness, quality of life and cost-effectiveness of Flaminal® versus Flamazine® in the treatment of partial thickness burns. In this two-arm open multi-center randomized controlled trial, 90 patients will be randomized between Flaminal® and Flamazine® and followed for 12 months. The study population will consist of competent or temporarily non-competent (because of sedation and/or intubation) patients, 18 years of age or older, with acute partial thickness burns and a total body surface area (TBSA) of less than 30 %. The main study outcome is time to complete re-epithelialization (greater than 95 %). Secondary outcome measures include need for grafting, wound colonization/infection, number of dressing changes, pain and anxiety, scar formation, health-related quality of life (HRQoL), and costs. This study will contribute to the optimal treatment of patients with partial thickness burn wounds and will provide evidence on the (cost-)effectiveness and quality of life of Flaminal® versus Flamazine® in the treatment of partial thickness burns. Netherlands Trial Register NTR4486 , registered on 2 April 2014.

  11. [Effectiveness of partial and complete instrumental masking in chronic tinnitus. Studies with reference to retraining therapy].

    Science.gov (United States)

    von Wedel, H; von Wedel, U C; Streppel, M; Walger, M

    1997-09-01

    Jastreboff und Hazell [9] developed a neurophysiological approach to tinnitus perception, including the important role of the central nervous system in the maintenance and intrusiveness of tinnitus. They introduced tinnitus-retraining therapy, consisting of four different strategies: (1) directive and person-centered counseling; (2) hearing aids and/or noise generators and/or environmental sounds; (3) psychological therapy; (4) adjacent therapies. Tinnitus should not be masked as with a tinnitus-masker, but must be able to be heard in addition to the noise! A noise generator or hearing aid should be worn at least 6-8 h per day over a period of up to 18 months. In additions several clinical visits are required in order to reinforce the counseling. The actual results show complete tinnitus remission for about 20-30% and partial remission for 50-60% of the patients [6]. We report on a retrospective study in patients wearing hearing aids or tinnitus-maskers over a period of 3 years. We compared the results of patients using partial tinnitus masking to those using complete masking. The tinnitus-related and general psychological complaints were acquired by the 52-item tinnitus questionnaire developed by Hallam et al. [4] and modified by Goebel and Hiller [3]. To describe the dimensions of tinnitus-related distress the scales are labelled emotional distress, cognitive distress, emotional and cognitive distress, intrusiveness, auditory perceptual difficulties, sleep disturbance and somatic complaints. Positive changes for the global tinnitus questionnaire score of more than 10 points are significant in the dimensions of tinnitus-related distress and are described as partial tinnitus-reduction. The group with partial masking effects can be compared to those performing retraining therapy to day because directive and personal centered counseling were integrated for all patients. Patients reporting partial masking effects through their aids (hearing aid or noise generator

  12. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    Energy Technology Data Exchange (ETDEWEB)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-10-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure (12 cmH2O continuous positive airway pressure (CPAP)) or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH2O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH2O; clearance and FRC were determined at CPAP of 12 cmH2O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method.

  13. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    International Nuclear Information System (INIS)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-01-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure [12 cmH 2 O continuous positive airway pressure (CPAP)] or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH 2 O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH 2 O; clearance and FRC were determined at CPAP of 12 cmH 2 O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method

  14. Efeito do exercício físico sobre o volume nasal Effects of physical exercise in nasal volume

    Directory of Open Access Journals (Sweden)

    Marconi Teixeira Fonseca

    2006-04-01

    Full Text Available A variação da permeabilidade nasal tem sido demonstrada usando-se várias técnicas de exame. As estruturas nasais geram uma resistência que representa cerca de 50% da resistência respiratória total. O exercício físico é um dos fatores que pode causar um efeito vasoconstritor sobre a mucosa nasal. OBJETIVO: O objetivo deste estudo é avaliar o grau de mudança do volume nasal após exercício físico e o tempo de retorno aos níveis basais. MATERIAIS E MÉTODOS: Dezenove indivíduos foram submetidos à realização de teste físico em bicicleta ergométrica. O volume nasal foi obtido através da rinometria acústica, realizada em repouso, após o fim do exercício físico, e nos minutos décimo e vigésimo de seu final. RESULTADOS: Os resultados rinométricos mostram um aumento estatisticamente significativo do volume nasal (p The nasal permeability has been demonstrated using several exams. Nasal structures produces a resistance to the nasal air flux that represents over 50% of the total respiratory resistance. Physical exercises is a factor that brings a vasoconstrictor effect over nasal mucosa. AINS: Evaluate the improvement degree of nasal volume after aerobic physical exercises and time to return to previous levels. SUBJECTS AND METHODS: Nineteen heathly subjects were submitted to aerobic exercise in ergometric bike. The nasal volume was obtained by Acoustic Rhinometry perfomed in rest, after aerobic exercise, 10o and 20o minutes after the aerobic exercise. RESULTS: Rhynometrics results shows a statically and significant increase of nasal volume (p<0,001. The nasal volume, in twenty minutes, returns nearby the rest levels. CONCLUSIONS: Aerobic exercises, generally, increases the nasal volume. However, the increase of nasal volume was transitory, and occurs a major reduction of increase in the first ten minutes after the exercises ends, and perform a greater vasoconstrictor effect over nasal mucosa, Twenty minutes after the physical

  15. The effect of future time perspective on delay discounting is mediated by the gray matter volume of vmPFC.

    Science.gov (United States)

    Guo, Yiqun; Chen, Zhiyi; Feng, Tingyong

    2017-07-28

    Although several previous studies have shown that individuals' attitude towards time could affect their intertemporal preference, little is known about the neural basis of the relation between time perspective (TP) and delay discounting. In the present study, we quantified the gray matter (GM) cortical volume using voxel-based morphometry (VBM) methods to investigate the effect of TP on delay discounting (DD) across two independent samples. For group 1 (102 healthy college students; 46 male; 20.40 ± 1.87 years), behavioral results showed that only Future TP was a significant predictor of DD, and higher scores on Future TP were related to lower discounting rates. Whole-brain analysis revealed that steeper discounting correlated with greater GM volume in the ventromedial prefrontal cortex (vmPFC) and ventral part of posterior cingulate cortex (vPCC). Also, GM volume of a cluster in the vmPFC was correlated with Future TP. Interestingly, there was an overlapping region in vmPFC that was correlated with both DD and Future TP. Region-of-interest analysis further indicated that the overlapping region of vmPFC played a partially mediating role in the relation between Future TP and DD in the other independent dataset (Group 2, 36 healthy college students; 14 male; 20.18±1.80 years). Taken together, our results provide a new perspective from neural basis for explaining the relation between DD and future TP. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Lack of gender effects on gray matter volumes in adolescent generalized anxiety disorder.

    Science.gov (United States)

    Liao, Mei; Yang, Fan; Zhang, Yan; He, Zhong; Su, Linyan; Li, Lingjiang

    2014-02-01

    Previous epidemiological and clinical studies have reported gender differences in prevalence and clinical features of generalized anxiety disorder (GAD). Such gender differences in clinical phenomenology suggest that the underlying neural circuitry of GAD could also be different in males and females. This study aimed to explore the possible gender effect on gray matter volumes in adolescents with GAD. Twenty-six adolescent GAD patients and 25 healthy controls participated and underwent high-resolution structural magnetic resonance scans. Voxel-based morphometry (VBM) was used to investigate gray matter alterations. Our study revealed a significant diagnosis main effect in the right putamen, with larger gray matter volumes in GAD patients compared to healthy controls, and a significant gender main effect in the left precuneus/posterior cingulate cortex, with larger gray matter volumes in males compared to females. No gender-by-diagnosis interaction effect was found in this study. The relatively small sample size in this study might result in a lack of power to demonstrate gender effects on brain structure in GAD. The results suggested that there are differences in gray matter volumes between males and females, but gray matter volumes in GAD are not influenced by gender. © 2013 Published by Elsevier B.V.

  17. Dual effect of insulin on plasma volume and transcapillary albumin transport

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J

    1992-01-01

    vascular dilatation and increased muscle sympathetic nerve activity during a euglycaemic glucose clamp. During similar conditions insulin increased the transcapillary escape rate of albumin and reduced plasma volume. Insulin has also an indirect effect on vascular permeability during hypoglycaemia, which...... is mediated by the increase in plasma adrenaline. Adrenaline infusion increased haematocrit and decreased plasma volume and intravascular albumin mass. In contrast to insulin adrenaline did not increase the transcapillary escape rate of albumin. Total autonomic blockade during insulin-induced hypoglycaemia...... abolished the increase in haematocrit, but did not influence the decrease in plasma volume and the increase in the transcapillary escape rate of albumin. Insulin administration may also increase urinary albumin excretion, and this effect was observed during a euglycaemic clamp. The mechanism of the increase...

  18. Effects of partial shading conditions on maximum power points and mismatch losses in silicon-based photovoltaic power generators

    Energy Technology Data Exchange (ETDEWEB)

    Maki, A.

    2013-11-01

    Photovoltaic (PV) power generators can be used for converting the energy of solar radiation directly into electrical energy without any moving parts. The operation of the generators is highly affected by operating conditions, most importantly irradiances and temperatures of PV cells. PV power generators are prone to electrical losses if the operating conditions are non-uniform such as in a case where part of the modules of a generator are shaded while the rest are receiving the global solar radiation. These conditions are called partial shading conditions and they have been recognized as a major cause of energy losses in PV power generators. In this thesis, the operation of silicon-based PV power generators under partial shading conditions is studied using Matlab Simulink simulation model. The operation of the model has been verified by measurements of electrical characteristics of a PV module under several different operating conditions and also under partial shading conditions. A systematic approach to study the effects of partial shading conditions has been developed and used. In addition to the systematic approach, a vast amount of data measured from the Tampere University of Technology (TUT) Solar Photovoltaic Power Station Research Plant are analyzed and used as input for the simulation model to study operation of PV power generators under actual operating conditions. Partial shading conditions have severe effects on the electrical characteristics of PV power generators and can cause multiple maximum power points (MPPs) to the power-voltage curve of the generators. In most cases, partial shading conditions lead to the occurrence of multiple MPPs, but also only one MPP can be present despite of partial shading. Reasons for this phenomenon are presented and analyzed in this thesis. Because of multiple MPPs, a considerable amount of available electrical energy may be lost when the generator is operating at a local MPP with low power instead of the global MPP. In

  19. Measurement and correlation of excess molar volumes for mixtures of 1-propanol and aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Gahlyan, Suman; Rani, Manju; Maken, Sanjeev Kumar; Lee, Inkyu; Moon, Il

    2015-01-01

    Excess molar volumes (V m E ) have been measured at 303.15 K for 1-propanol+benzene or toluene or o- or m- or p-xylene mixtures using V-shape dilatometer. The V m E values, for an equimolar composition, vary in the order: benzene>toluene-m-xylene>o-xylene>p-xylene. The V m E data have been used to calculate partial molar volumes, excess partial molar volumes, and apparent molar volumes of 1-propanol and aromatic hydrocarbons over the entire range of composition. The excess volume data have also been interpreted in terms of graph-theoretical approach and Prigogine-Flory-Patterson theory (PFP). While PFP theory fails to predict the V m E values for systems with s-shaped V m E versus x 1 graph, the V m E values calculated by graph theory compare reasonably well with the corresponding experimental values. This graph theory analysis has further yielded information about the state of aggregation of pure components as well as of the mixtures

  20. Effect of catecholamines and insulin on plasma volume and intravascular mass of albumin in man

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1989-01-01

    1. The effect of intravenous catecholamine infusions and of intravenous insulin on plasma volume and intravascular mass of albumin was investigated in healthy males. 2. Physiological doses of adrenaline (0.5 microgram/min and 3 microgram/min) increased peripheral venous packed cell volume...... significantly; intravenous noradrenaline at 0.5 microgram/min had no effect on packed cell volume, whereas packed cell volume increased significantly at 3 micrograms of noradrenaline/min. No significant change in packed cell volume was found during saline infusion. 3. During adrenaline infusion at 6 micrograms...... in packed cell volume, plasma volume, intravascular mass of albumin and transcapillary escape rate of albumin during hypoglycaemia may be explained by the combined actions of adrenaline and insulin....

  1. Harmonic analysis, partial differential equations and applications in honor of Richard L. Wheeden

    CERN Document Server

    Franchi, Bruno; Lu, Guozhen; Perez, Carlos; Sawyer, Eric

    2017-01-01

    This is a collection of contributed papers by many eminent Harmonic Analysts and specialists of Partial Differential equations. The papers focus on weighted norm equalities for singular integrals, focusing wave equations, degenerate elliptic equations, Navier-Stokes flow in two dimensions and Poincare-Sobolev inequalities in the setting of metric spaces equipped with measures among others. Many topics considered in this volume stem from the interests of Richard L. Wheeden whose contributions to Potential Theory, singular integral theory and degenerate elliptic PDE theory this volume honors. Luis Caffarelli, Sagun Chanillo, Bruno Franchi, Cristian Guttierez, Xiaojun Huang, Carlos Kenig, Ermanno Lanconelli, Eric Sawyer and Alexander Volberg, are some of the many contributors to this volume. .

  2. Partial differential equations methods, applications and theories

    CERN Document Server

    Hattori, Harumi

    2013-01-01

    This volume is an introductory level textbook for partial differential equations (PDE's) and suitable for a one-semester undergraduate level or two-semester graduate level course in PDE's or applied mathematics. Chapters One to Five are organized according to the equations and the basic PDE's are introduced in an easy to understand manner. They include the first-order equations and the three fundamental second-order equations, i.e. the heat, wave and Laplace equations. Through these equations we learn the types of problems, how we pose the problems, and the methods of solutions such as the separation of variables and the method of characteristics. The modeling aspects are explained as well. The methods introduced in earlier chapters are developed further in Chapters Six to Twelve. They include the Fourier series, the Fourier and the Laplace transforms, and the Green's functions. The equations in higher dimensions are also discussed in detail. This volume is application-oriented and rich in examples. Going thr...

  3. Finite Volume Effect of Baryons in Strange Hadronic Matter

    Institute of Scientific and Technical Information of China (English)

    SUN Bao-Xi; LI Lei; NING Ping-Zhi; ZHAO En-Guang

    2001-01-01

    The finite volume effect of baryons in strange hadronic matter (SHM) is studied within the framework of relativistic mean-field theory. As this effect is concerned, the saturation density of SHM turns lower, and the binding energy per baryon decreases. Its influence to the compression modulus of SHM is also discussed.

  4. The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

    Science.gov (United States)

    Burton, R. R.; Smith, A. H.

    1972-01-01

    Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

  5. Partial lower axillary dissection for patients with clinically node-negative breast cancer.

    Science.gov (United States)

    Kodama, H; Mise, K; Kan, N

    2012-01-01

    To evaluate retrospectively the outcomes of partial lower axillary lymph node dissection caudal to the intercostobrachial nerve in patients with clinically node-negative (N(0)) breast cancer. Numbers of dissected and metastatic nodes, overall and disease-free survival rates, postoperative complication rates, and axillary recurrence were compared between patients who underwent breast cancer surgery with partial axillary node dissection (n = 1043) and historical controls who underwent conventional dissection (n = 1084). The 5-year overall and disease-free survival rates were 95.6% and 89.7%, and 94.9% and 88.4%, respectively, in the partial dissection and conventional dissection groups; the differences were not significant. Mean duration of surgery (41.6 min versus 60.9 min), intraoperative blood loss (28.0 ml versus 51.3 ml), volume of lymphatic drainage at 2 weeks postoperatively (488 ml versus 836 ml), and persistent arm lymphoedema (0.0% versus 11.8%) were significantly different between the partial and conventional dissection groups, respectively. Partial axillary lymph node dissection was associated with similar survival rates (but lower postoperative complication rates) compared with conventional axillary dissection and is recommended in patients with N(0) breast cancer.

  6. Technical Note: Deformable image registration on partially matched images for radiotherapy applications

    International Nuclear Information System (INIS)

    Yang Deshan; Goddu, S. Murty; Lu Wei; Pechenaya, Olga L.; Wu Yu; Deasy, Joseph O.; El Naqa, Issam; Low, Daniel A.

    2010-01-01

    In radiation therapy applications, deformable image registrations (DIRs) are often carried out between two images that only partially match. Image mismatching could present as superior-inferior coverage differences, field-of-view (FOV) cutoffs, or motion crossing the image boundaries. In this study, the authors propose a method to improve the existing DIR algorithms so that DIR can be carried out in such situations. The basic idea is to extend the image volumes and define the extension voxels (outside the FOV or outside the original image volume) as NaN (not-a-number) values that are transparent to all floating-point computations in the DIR algorithms. Registrations are then carried out with one additional rule that NaN voxels can match any voxels. In this way, the matched sections of the images are registered properly, and the mismatched sections of the images are registered to NaN voxels. This method makes it possible to perform DIR on partially matched images that otherwise are difficult to register. It may also improve DIR accuracy, especially near or in the mismatched image regions.

  7. Evaluating the effect of crumb rubber and nano silica on the properties of high volume fly ash roller compacted concrete pavement using non-destructive techniques

    Directory of Open Access Journals (Sweden)

    Bashar S. Mohammed

    2018-06-01

    Full Text Available The major problems related to roller compacted concrete (RCC pavement are high rigidity, lower tensile strength which causes a tendency of cracking due to thermal or plastic shrinkage, flexural and fatigue loads. Furthermore, RCC pavement does not support the use of dowel bars or reinforcement due to the way it is placed and compacted, these also aided in cracking and consequently increased maintenance cost. To address these issues, high volume fly ash (HVFA RCC pavement was developed by partially replacing 50% cement by volume with fly ash. Crumb rubber was used as a partial replacement to fine aggregate in HVFA RCC pavement at 0%, 10%, 20%, and 30% replacement by volume. Nano silica was added at 0%, 1%, 2% and 3% by weight of cementitious materials to improve early strength development in HVFA RCC pavement and mitigate the loss of strength due to the incorporation of crumb rubber. The nondestructive technique using the rebound hammer test (RHT and ultrasonic pulse velocity (UPV were used to evaluate the effect of crumb rubber and nano silica on the performance of HVFA RCC pavement. The results showed that the use of HVFA as cement replacement decreases both the unit weight, compressive strength, rebound number (RN. Furthermore, the unit weight, compressive strength, RN, UPV and dynamic modulus of elasticity of HVFA RCC pavement all decreases with increase in crumb rubber content and increases with the addition of nano-silica. Combined UPV-RN (SonReb models for predicting the 28 days strength of HVFA RCC pavement based on combining UPV and RN were developed using multivariable regression (double power, bilinear, and double exponential models. The exponential combined SonReb model is the most suitable for predicting the compressive strength of HVFA RCC pavement using UPV and RN as the independent variable with better predicting ability, higher correlation compared to the single variable models. Keywords: Crumb rubber, High volume fly ash, Nano

  8. Effects of extract of Buddleja officinalis on partial inflammation of lacrimal gland in castrated rabbits with dry eye.

    Science.gov (United States)

    Yao, Xiao-Lei; Peng, Qing-Hua; Peng, Jun; Tan, Han-Yu; Wu, Quan-Long; Wu, Da-Li; Chen, Mei; Li, Chuan-Ke; Li, Dian; Zhu, Hui-An

    2010-01-01

    To assess the effects of extract of Buddleja officinalis on tear secretion volume, tear film stability, expressions of TGF-β1, IL-1β, TNF-α in lacrimal gland of castrated rabbits with dry eye. A total of 30 victory rabbits were divided averagely into normal group(A), model group(B), therapy group with low dose extract of Buddleja officinalis (C), therapy group with high dose extract of Buddleja officinalis (D) and therapy group with genistein (E). The dry eye model was established with orchiectomy on Group B, C, D, E. Group C, D, E were administered intragastrically with corresponding dose extract of Buddleja officinalis or genistein for 30 days. All rabbits were detected with SIT. TGF-β1, IL-1β, TNF-α were detected with immunohistochemistry and the ultrastructure of lacrimal gland was observed under transmission electron microscope. The SIT value of group C, D, E were respectively 13.167±4.957, 14.667±5.279, 8.667±0.516, obviously higher than that of group B 5.667±2.338 (PBuddleja officinalis can adjust lacrimal gland partial inflammation of dry eye.

  9. Partial slip effect in flow of magnetite-Fe{sub 3}O{sub 4} nanoparticles between rotating stretchable disks

    Energy Technology Data Exchange (ETDEWEB)

    Hayat, Tasawar [Department of Mathematics, Quaid-I-Azam University 45320, Islamabad 44000 (Pakistan); Nonlinear Analysis and Applied Mathematics (NAAM) Research Group, Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Qayyum, Sumaira [Department of Mathematics, Quaid-I-Azam University 45320, Islamabad 44000 (Pakistan); Imtiaz, Maria, E-mail: mi_qau@yahoo.com [Department of Mathematics, Quaid-I-Azam University 45320, Islamabad 44000 (Pakistan); Alzahrani, Faris; Alsaedi, Ahmed [Nonlinear Analysis and Applied Mathematics (NAAM) Research Group, Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah 21589 (Saudi Arabia)

    2016-09-01

    This paper addresses the flow of magnetic nanofluid (ferrofluid) between two parallel rotating stretchable disks with different rotating and stretching velocities. Water based fluid comprising magnetite-Fe{sub 3}O{sub 4} nanoparticles is addressed. Velocity slip and temperature jump at solid–fluid interface are also taken into account. Appropriate transformations reduce the nonlinear partial differential system to ordinary differential system. Convergent series solutions are obtained. Effects of various pertinent parameters on the velocity and temperature profiles are shown and evaluated. Computations for skin friction coefficient and Nusselt number are presented and examined for the influence of involved parameters. It is noted that tangential velocity of fluid decreases for larger velocity slip parameter. Fluid temperature also reduces for increasing value of thermal slip parameter. Surface drag force and heat transfer rate at lower disk are enhanced when magnetic field strength is increased. - Highlights: • Flow and heat transfer of ferrofluid induced by two stretchable rotating disks with velocity and thermal slips are explored. • Fluid temperature increases for larger solid volume fraction of nanofluid. • Heat transfer rate decreases for increasing values of thermal slip parameter.

  10. Nonlinear partial differential equations and their applications

    CERN Document Server

    Lions, Jacques Louis

    2002-01-01

    This book contains the written versions of lectures delivered since 1997 in the well-known weekly seminar on Applied Mathematics at the Collège de France in Paris, directed by Jacques-Louis Lions. It is the 14th and last of the series, due to the recent and untimely death of Professor Lions. The texts in this volume deal mostly with various aspects of the theory of nonlinear partial differential equations. They present both theoretical and applied results in many fields of growing importance such as Calculus of variations and optimal control, optimization, system theory and control, op

  11. Partial ablation of uropygial gland effect on carcass characteristics of Akar Putra chicken.

    Science.gov (United States)

    Jawad, Hasan S A; Idris, L H; Bakar, Z B; Kassim, A B

    2016-08-01

    This study evaluated the effect of partial uropygialectomy (PU) on carcass traits of male and female Akar Putra chickens. Sixty chicks of each sex were evenly distributed into 5 treatment groups with 3 replicates per group containing 4 males and 4 females each, and reared for 12 wk. Homogeneity of the groups was satisfied with regard to the parity. Experimental treatments consisted of a control treatment (T1), and partial ablation of the uropygial gland was applied on the second, third, fourth, and fifth treatments at 3, 4, 5, and 6 wk of age, respectively. The chickens were fed ad libitum the same diets (1 to 13 d: starter; 14 d to slaughter: finisher). On the last d of the experiment, 12 birds were randomly selected from each treatment group (2 males and 2 females per replicate) and slaughtered to determine carcass characteristics, which included carcass weight, dressing percentage with or without eating giblets, and the relative weights of heart, liver, gizzard, thighs, wings, breast, back, and neck. From the results of the study, it was shown that the partial ablation of the uropygial gland at all ages had certain dependent effects concerning some carcass parameters, as shown by higher breast and back relative weights in males and breast relative weight in females. As a consequence, a positive effect also was noticed regarding the carcass morphology in terms of the increase in dressing percentage with or without eating giblets thus leading to an increase in the body weight and carcass weight. Furthermore, the best result was obtained in the second treatment when PU was applied at 3 wk of age compared with other experimental groups. Moreover, the current study provides a novel and economic alternative to enhance the body performance of poultry in general and Akar Putra chicken particularly. © 2016 Poultry Science Association Inc.

  12. Adaptive radiotherapy in muscle invasive urinary bladder cancer - An effective method to reduce the irradiated bowel volume

    International Nuclear Information System (INIS)

    Tuomikoski, Laura; Collan, Juhani; Keyrilaeinen, Jani; Visapaeae, Harri; Saarilahti, Kauko; Tenhunen, Mikko

    2011-01-01

    Background and purpose: To evaluate the benefits of adaptive radiotherapy for bladder cancer in decreasing irradiation of small bowel. Material and methods: Five patients with muscle invasive bladder cancer received adaptive radiotherapy to a total dose of 55.8-65 Gy with daily cone-beam computed tomography scanning. The whole bladder was treated to 45-50.4 Gy, followed by a partial bladder boost. The plan of the day was chosen from 3 to 4 pre-planned treatment plans according to the visible extent of bladder wall in cone-beam computed tomography images. Dose volume histograms for intestinal cavity volumes were constructed and compared with corresponding histograms calculated for conventional non-adaptive radiotherapy with single treatment plan of 2 cm CTV-PTV margins. CTV dose coverage in adaptive treatment technique was compared with CTV dose coverage in conventional radiotherapy. Results: The average volume of intestinal cavity receiving ≥45 Gy was reduced from 335 ± 106 cm 3 to 180 ± 113 cm 3 (1SD). The maximum volume of intestinal cavity spared at 45 Gy on a single patient was 240 cm 3 , while the minimum volume was 65 cm 3 . The corresponding reduction in average intestinal cavity volume receiving ≥45 Gy calculated for the whole bladder treatment only was 66 ± 36 cm 3 . CTV dose coverage was improved on two out of five patients and decreased on three patients. Conclusions: Adaptive radiotherapy considerably reduces dose to the small bowel, while maintaining the dose coverage of CTV at similar level when compared to the conventional treatment technique.

  13. The Effect of Influent Characteristics and Operational Conditions over the Performance and Microbial Community Structure of Partial Nitritation Reactors

    Directory of Open Access Journals (Sweden)

    Alejandro Rodriguez-Sanchez

    2014-06-01

    Full Text Available Nitrogen is a main contaminant of wastewater worldwide. Novel processes for nitrogen removal have been developed over the last several decades. One of these is the partial nitritation process. This process includes the oxidation of ammonium to nitrite without the generation of nitrate. The partial nitritation process has several advantages over traditional nitrification-denitrification processes for nitrogen removal from wastewaters. In addition, partial nitritation is required for anammox elimination of nitrogen from wastewater. Partial nitritation is affected by operational conditions and substances present in the influent, such as quinolone antibiotics. In this review, the impact that several operational conditions, such as temperature, pH, dissolved oxygen concentration, hydraulic retention time and solids retention time, have over the partial nitritation process is covered. The effect of quinolone antibiotics and other emerging contaminants are discussed. Finally, future perspectives for the partial nitritation process are commented upon.

  14. The Synthesis of Calcium Salt from Brine Water by Partial Evaporation and Chemical Precipitation

    Science.gov (United States)

    Lalasari, L. H.; Widowati, M. K.; Natasha, N. C.; Sulistiyono, E.; Prasetyo, A. B.

    2017-02-01

    In this study would be investigated the effects of partial evaporation and chemical precipitation in the formation of calcium salt from brine water resources. The chemical reagents used in the study was oxalate acid (C2H2O4), ammonium carbonate (NH4)2CO3) and ammonium hydroxide (NH4OH) with reagent concentration of 2 N, respectively. The procedure was 10 liters brine water evaporated until 20% volume and continued with filtration process to separate brine water filtrate from residue (salt). Salt resulted from evaporation process was characterized by Scanning Electron Microscopy (SEM), X-Ray Fluorescence (XRF) and X-Ray Diffraction (XRD) techniques. Filtrate then was reacted with C2H2O4, (NH4)2CO3 and NH4OH reagents to get salt products in atmospheric condition and variation ratio volume brine water/chemicals (v/v) [10/1; 10/5; 10/10; 10/20; 10/30; 10:50; 20/1; 20/5; 20/10; 20/20; 20/30; 20:50]. The salt product than were filtered, dried, measured weights and finally characterized by SEM/EDS and XRD techniques. The result of experiment showed the chemical composition of brine water from Tirta Sanita, Bogor was 28.87% Na, 9.17% Mg, 2.94% Ca, 22.33% O, 0.71% Sr, 30.02% Cl, 1.51% Si, 1.23% K, 0.55% S, 1.31% Al. The chemical composition of salt resulted by partial evaporation was 53.02% Ca, 28.93%O, 9.50% Na, 2.10% Mg, 1.53% Sr, 1.20% Cl, 1.10% Si, 0.63% K, 0.40% S, 0.39% Al. The salt resulted by total evaporation was indicated namely as NaCl. Whereas salt resulted by partial evaporation was CaCO3 with a purity of 90 % from High Score Plus analysis. In the experiment by chemical precipitation was reported that the reagents of ammonium carbonate were more reactive for synthesizing calcium salt from brine water compared to reagents of oxalate acid and ammonium hydroxide. The salts precipitated by NH4OH, (NH4)2CO3, and H2C2O4 reagents were indicated as NaCl, CaCO3 and CaC2O4.H2O, respectively. The techniques of partial evaporation until 20% volume sample of brine water and

  15. Application of ERAS-model and Prigogine-Flory-Patterson theory to excess molar volumes for ternary mixtures of (2-chlorobutane + butylacetate + isobutanol) at T = 298.15 K

    International Nuclear Information System (INIS)

    Khanlarzadeh, K.; Iloukhani, H.

    2011-01-01

    Highlights: → Density of ternary and three binary mixtures of (2-chlorobutane + butylacetate + isobutanol) determined. → Excess molar volume, partial molar volume and apparent molar volume were calculated. → Excess molar volume was correlated as a function of mole fraction by using the Redlich-Kister and Cibulka equation for all mixtures. → The experimental results have been used to test the applicability of the ERAS-model and PFP theory. - Abstract: Densities of the ternary mixture consisting of {2-chlorobutane (1) + butylacetate (2) + isobutanol (3)} and related binary mixtures were measured over the whole range of composition at T = 298.15 K and ambient pressure. Excess molar volumes V m E for the mixtures were derived and correlated as a function of mole fraction by using the Redlich-Kister and the Cibulka equations for binary and ternary mixtures, respectively. From the experimental data, partial molar volumes, V-bar m,i excess partial molar volumes, V-bar i E partial molar volumes at infinite dilution V-bar m,i 0 and apparent molar volumes V-bar φ,i were also calculated. For all binary mixtures over the entire range of mole fractions V m E data are positive. The experimental results of the constituted binary mixtures have been used to test the applicability of the extended real associated solution (ERAS-model) and Prigogine-Flory-Paterson (PFP) theory.

  16. Excluded-volume effects in the diffusion of hard spheres

    KAUST Repository

    Bruna, Maria; Chapman, S. Jonathan

    2012-01-01

    Excluded-volume effects can play an important role in determining transport properties in diffusion of particles. Here, the diffusion of finite-sized hard-core interacting particles in two or three dimensions is considered systematically using

  17. Studies on the partial specific volume of a poly(ethylene glycol) derivative in different solvent systems

    NARCIS (Netherlands)

    Tziatzios, C.; Precup, A.A.; Weidl, C.H.; Schubert, U.S.; Schuck, P.; Durchschlag, H.; Mächtle, W.; Broek, van den J.A.; Schubert, D.

    2002-01-01

    The specific volume of charged supramolecular compounds dissolved in organic solvents varies considerably with the solvent system applied; in addition, it is influenced by the presence of salt. In this study we determined the specific volume of an uncharged molecule from the same molar mass range in

  18. Tumor Volume Estimation and Quasi-Continuous Administration for Most Effective Bevacizumab Therapy.

    Science.gov (United States)

    Sápi, Johanna; Kovács, Levente; Drexler, Dániel András; Kocsis, Pál; Gajári, Dávid; Sápi, Zoltán

    2015-01-01

    Bevacizumab is an exogenous inhibitor which inhibits the biological activity of human VEGF. Several studies have investigated the effectiveness of bevacizumab therapy according to different cancer types but these days there is an intense debate on its utility. We have investigated different methods to find the best tumor volume estimation since it creates the possibility for precise and effective drug administration with a much lower dose than in the protocol. We have examined C38 mouse colon adenocarcinoma and HT-29 human colorectal adenocarcinoma. In both cases, three groups were compared in the experiments. The first group did not receive therapy, the second group received one 200 μg bevacizumab dose for a treatment period (protocol-based therapy), and the third group received 1.1 μg bevacizumab every day (quasi-continuous therapy). Tumor volume measurement was performed by digital caliper and small animal MRI. The mathematical relationship between MRI-measured tumor volume and mass was investigated to estimate accurate tumor volume using caliper-measured data. A two-dimensional mathematical model was applied for tumor volume evaluation, and tumor- and therapy-specific constants were calculated for the three different groups. The effectiveness of bevacizumab administration was examined by statistical analysis. In the case of C38 adenocarcinoma, protocol-based treatment did not result in significantly smaller tumor volume compared to the no treatment group; however, there was a significant difference between untreated mice and mice who received quasi-continuous therapy (p = 0.002). In the case of HT-29 adenocarcinoma, the daily treatment with one-twelfth total dose resulted in significantly smaller tumors than the protocol-based treatment (p = 0.038). When the tumor has a symmetrical, solid closed shape (typically without treatment), volume can be evaluated accurately from caliper-measured data with the applied two-dimensional mathematical model. Our results

  19. Cul3-mediated Nrf2 ubiquitination and antioxidant response element (ARE) activation are dependent on the partial molar volume at position 151 of Keap1.

    Science.gov (United States)

    Eggler, Aimee L; Small, Evan; Hannink, Mark; Mesecar, Andrew D

    2009-07-29

    Nrf2 (nuclear factor erythroid 2-related factor 2) is a transcription factor that activates transcription of a battery of cytoprotective genes by binding to the ARE (antioxidant response element). Nrf2 is repressed by the cysteine-rich Keap1 (kelch-like ECH-associated protein 1) protein, which targets Nrf2 for ubiquitination and subsequent degradation by a Cul3 (cullin 3)-mediated ubiquitination complex. We find that modification of Cys(151) of human Keap1, by mutation to a tryptophan, relieves the repression by Keap1 and allows activation of the ARE by Nrf2. The Keap1 C151W substitution has a decreased affinity for Cul3, and can no longer serve to target Nrf2 for ubiquitination, though it retains its affinity for Nrf2. A series of 12 mutant Keap1 proteins, each containing a different residue at position 151, was constructed to explore the chemistry required for this effect. The series reveals that the extent to which Keap1 loses the ability to target Nrf2 for degradation, and hence the ability to repress ARE activation, correlates well with the partial molar volume of the residue. Other physico-chemical properties do not appear to contribute significantly to the effect. Based on this finding, a structural model is proposed whereby large residues at position 151 cause steric clashes that lead to alteration of the Keap1-Cul3 interaction. This model has significant implications for how electrophiles which modify Cys(151), disrupt the repressive function of Keap1.

  20. Effective slip over partially filled microcavities and its possible failure

    Science.gov (United States)

    Ge, Zhouyang; Holmgren, Hanna; Kronbichler, Martin; Brandt, Luca; Kreiss, Gunilla

    2018-05-01

    Motivated by the emerging applications of liquid-infused surfaces (LIS), we study the drag reduction and robustness of transverse flows over two-dimensional microcavities partially filled with an oily lubricant. Using separate simulations at different scales, characteristic contact line velocities at the fluid-solid intersection are first extracted from nanoscale phase field simulations and then applied to micronscale two-phase flows, thus introducing a multiscale numerical framework to model the interface displacement and deformation within the cavities. As we explore the various effects of the lubricant-to-outer-fluid viscosity ratio μ˜2/μ˜1 , the capillary number Ca, the static contact angle θs, and the filling fraction of the cavity δ , we find that the effective slip is most sensitive to the parameter δ . The effects of μ˜2/μ˜1 and θs are generally intertwined but weakened if δ 1 ), however, are immune to such failure due to their generally larger contact line velocity.

  1. The effects of intracranial volume adjustment approaches on multiple regional MRI volumes in healthy aging and Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Olga eVoevodskaya

    2014-10-01

    Full Text Available In neurodegeneration research, normalization of regional volumes by intracranial volume (ICV is important to estimate the extent of disease-driven atrophy. There is little agreement as to whether raw volumes, volume-to-ICV fractions or regional volumes from which the ICV factor has been regressed out should be used for volumetric brain imaging studies. Using multiple regional cortical and subcortical volumetric measures generated by Freesurfer (51 in total, the main aim of this study was to elucidate the implications of these adjustment approaches. Magnetic resonance imaging (MRI data were analyzed from two large cohorts, the population-based PIVUS cohort (N=406, all subjects age 75 and the Alzheimer disease Neuroimaging Initiative (ADNI cohort (N=724. Further, we studied whether the chosen ICV normalization approach influenced the relationship between hippocampus and cognition in the three diagnostic groups of the ADNI cohort (Alzheimer’s disease, mild cognitive impairment and healthy individuals. The ability of raw vs adjusted hippocampal volumes to predict diagnostic status was also assessed. In both cohorts raw volumes correlate positively with ICV, but do not scale directly proportionally with it. The correlation direction is reversed for all volume-to-ICV fractions, except the lateral and third ventricles. Most grey matter fractions are larger in females, while lateral ventricle fractions are greater in males. Residual correction effectively eliminated the correlation between the regional volumes and ICV and removed gender differences. The association between hippocampal volumes and cognition was not altered by ICV normalization. Comparing prediction of diagnostic status using the different approaches, small but significant differences were found. The choice of normalization approach should be carefully considered when designing a volumetric brain imaging study.

  2. Physics of partially ionized plasmas

    CERN Document Server

    Krishan, Vinod

    2016-01-01

    Plasma is one of the four fundamental states of matter; the other three being solid, liquid and gas. Several components, such as molecular clouds, diffuse interstellar gas, the solar atmosphere, the Earth's ionosphere and laboratory plasmas, including fusion plasmas, constitute the partially ionized plasmas. This book discusses different aspects of partially ionized plasmas including multi-fluid description, equilibrium and types of waves. The discussion goes on to cover the reionization phase of the universe, along with a brief description of high discharge plasmas, tokomak plasmas and laser plasmas. Various elastic and inelastic collisions amongst the three particle species are also presented. In addition, the author demonstrates the novelty of partially ionized plasmas using many examples; for instance, in partially ionized plasma the magnetic induction is subjected to the ambipolar diffusion and the Hall effect, as well as the usual resistive dissipation. Also included is an observation of kinematic dynam...

  3. Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mori, Koichi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute and MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5 T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI. (author)

  4. [Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging].

    Science.gov (United States)

    Mori, Koichi; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute an MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI.

  5. Partially linear mixed-effects joint models for skewed and missing longitudinal competing risks outcomes.

    Science.gov (United States)

    Lu, Tao; Lu, Minggen; Wang, Min; Zhang, Jun; Dong, Guang-Hui; Xu, Yong

    2017-12-18

    Longitudinal competing risks data frequently arise in clinical studies. Skewness and missingness are commonly observed for these data in practice. However, most joint models do not account for these data features. In this article, we propose partially linear mixed-effects joint models to analyze skew longitudinal competing risks data with missingness. In particular, to account for skewness, we replace the commonly assumed symmetric distributions by asymmetric distribution for model errors. To deal with missingness, we employ an informative missing data model. The joint models that couple the partially linear mixed-effects model for the longitudinal process, the cause-specific proportional hazard model for competing risks process and missing data process are developed. To estimate the parameters in the joint models, we propose a fully Bayesian approach based on the joint likelihood. To illustrate the proposed model and method, we implement them to an AIDS clinical study. Some interesting findings are reported. We also conduct simulation studies to validate the proposed method.

  6. Effect of Extracorporeal Shock Wave Treatment on Deep Partial-Thickness Burn Injury in Rats: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Gabriel Djedovic

    2014-01-01

    Full Text Available Extracorporeal shock wave therapy (ESWT enhances tissue vascularization and neoangiogenesis. Recent animal studies showed improved soft tissue regeneration using ESWT. In most cases, deep partial-thickness burns require skin grafting; the outcome is often unsatisfactory in function and aesthetic appearance. The aim of this study was to demonstrate the effect of ESWT on skin regeneration after deep partial-thickness burns. Under general anesthesia, two standardized deep partial-thickness burns were induced on the back of 30 male Wistar rats. Immediately after the burn, ESWT was given to rats of group 1 (N=15, but not to group 2 (N=15. On days 5, 10, and 15, five rats of each group were analyzed. Reepithelialization rate was defined, perfusion units were measured, and histological analysis was performed. Digital photography was used for visual documentation. A wound score system was used. ESWT enhanced the percentage of wound closure in group 1 as compared to group 2 (P<0.05. The reepithelialization rate was improved significantly on day 15 (P<0.05. The wound score showed a significant increase in the ESWT group. ESWT improves skin regeneration of deep partial-thickness burns in rats. It may be a suitable and cost effective treatment alternative in this type of burn wounds in the future.

  7. Effect of cerebral spinal fluid suppression for diffusional kurtosis imaging.

    Science.gov (United States)

    Yang, Alicia W; Jensen, Jens H; Hu, Caixia C; Tabesh, Ali; Falangola, Maria F; Helpern, Joseph A

    2013-02-01

    To evaluate the cerebral spinal fluid (CSF) partial volume effect on diffusional kurtosis imaging (DKI) metrics in white matter and cortical gray matter. Four healthy volunteers participated in this study. Standard DKI and fluid-attenuated inversion recovery (FLAIR) DKI experiments were performed using a twice-refocused-spin-echo diffusion sequence. The conventional diffusion tensor imaging (DTI) metrics of fractional anisotropy (FA), mean, axial, and radial diffusivity (MD, D[symbol in text], D[symbol in text] together with DKI metrics of mean, axial, and radial kurtosis (MK, K[symbol in text], K[symbol in text], were measured and compared. Single image slices located above the lateral ventricles, with similar anatomical features for each subject, were selected to minimize the effect of CSF from the ventricles. In white matter, differences of less than 10% were observed between diffusion metrics measured with standard DKI and FLAIR-DKI sequences, suggesting minimal CSF contamination. For gray matter, conventional DTI metrics differed by 19% to 52%, reflecting significant CSF partial volume effects. Kurtosis metrics, however, changed by 11% or less, indicating greater robustness with respect to CSF contamination. Kurtosis metrics are less sensitive to CSF partial voluming in cortical gray matter than conventional diffusion metrics. The kurtosis metrics may then be more specific indicators of changes in tissue microstructure, provided the effect sizes for the changes are comparable. Copyright © 2012 Wiley Periodicals, Inc.

  8. Effects of (partial) quenching on penguin contributions to K→ππ

    NARCIS (Netherlands)

    Golterman, Maarten; Pallante, Elisabetta

    2004-01-01

    Recently, we pointed out that chiral transformation properties of strong penguin operators change in the transition from unquenched to (partially) quenched QCD. As a consequence, new penguinlike operators appear in the (partially) quenched theory, along with new low-energy constants, which should be

  9. Octanol-Water Partition Coefficient from 3D-RISM-KH Molecular Theory of Solvation with Partial Molar Volume Correction.

    Science.gov (United States)

    Huang, WenJuan; Blinov, Nikolay; Kovalenko, Andriy

    2015-04-30

    The octanol-water partition coefficient is an important physical-chemical characteristic widely used to describe hydrophobic/hydrophilic properties of chemical compounds. The partition coefficient is related to the transfer free energy of a compound from water to octanol. Here, we introduce a new protocol for prediction of the partition coefficient based on the statistical-mechanical, 3D-RISM-KH molecular theory of solvation. It was shown recently that with the compound-solvent correlation functions obtained from the 3D-RISM-KH molecular theory of solvation, the free energy functional supplemented with the correction linearly related to the partial molar volume obtained from the Kirkwood-Buff/3D-RISM theory, also called the "universal correction" (UC), provides accurate prediction of the hydration free energy of small compounds, compared to explicit solvent molecular dynamics [ Palmer , D. S. ; J. Phys.: Condens. Matter 2010 , 22 , 492101 ]. Here we report that with the UC reparametrized accordingly this theory also provides an excellent agreement with the experimental data for the solvation free energy in nonpolar solvent (1-octanol) and so accurately predicts the octanol-water partition coefficient. The performance of the Kovalenko-Hirata (KH) and Gaussian fluctuation (GF) functionals of the solvation free energy, with and without UC, is tested on a large library of small compounds with diverse functional groups. The best agreement with the experimental data for octanol-water partition coefficients is obtained with the KH-UC solvation free energy functional.

  10. Effects of partial portal vein arterialization on the hilar bile duct in a rat model.

    Science.gov (United States)

    Guo, Shao-Hua; Li, Chong-Hui; Chen, Yong-Liang; Song, Jian-Ning; Zhang, Ai-Qun; Zhou, Cheng

    2011-10-01

    Liver revascularization is frequently required during the enlarged radical operation for hilar cholangiocarcinoma involving the hepatic artery. Researchers have carried out a number of experiments applying partial portal vein arterialization (PVA) in clinical practice. In this study we aimed to establish a theoretical basis for clinical application of partial PVA and to investigate the effects of partial PVA on rat hilar bile duct and hepatic functions. Thirty rats were randomly and equally assigned into 3 groups: control (group A), hepatic artery ligation+bile duct recanalization (group B), and partial PVA+bile duct recanalization (group C). Proliferation and apoptosis of rat hilar bile duct epithelial cells, arteriolar counts of the peribiliary plexus (PBP) of the bile duct wall, changes in serum biochemistry, and pathologic changes in the bile duct were assessed 1 month after operation. The proliferation of hilar bile duct epithelial cells in group B was greater than in groups A and C (Philar bile duct epithelial cells were detected in any of the groups. The PBP arteriolar counts of the hilar bile duct wall were similar in groups A and C (P>0.05), but the count was lower in group B than in group A (Philar bile duct walls were observed only in group B. Partial PVA can restore the arterial blood supply of the hilar bile duct and significantly extenuate the injury to hilar bile duct epithelial cells resulting from hepatic artery ligation.

  11. Depth of Field Effects for Interactive Direct Volume Rendering

    KAUST Repository

    Schott, Mathias; Pascal Grosset, A.V.; Martin, Tobias; Pegoraro, Vincent; Smith, Sean T.; Hansen, Charles D.

    2011-01-01

    In this paper, a method for interactive direct volume rendering is proposed for computing depth of field effects, which previously were shown to aid observers in depth and size perception of synthetically generated images. The presented technique extends those benefits to volume rendering visualizations of 3D scalar fields from CT/MRI scanners or numerical simulations. It is based on incremental filtering and as such does not depend on any precomputation, thus allowing interactive explorations of volumetric data sets via on-the-fly editing of the shading model parameters or (multi-dimensional) transfer functions. © 2011 The Author(s).

  12. Depth of Field Effects for Interactive Direct Volume Rendering

    KAUST Repository

    Schott, Mathias

    2011-06-01

    In this paper, a method for interactive direct volume rendering is proposed for computing depth of field effects, which previously were shown to aid observers in depth and size perception of synthetically generated images. The presented technique extends those benefits to volume rendering visualizations of 3D scalar fields from CT/MRI scanners or numerical simulations. It is based on incremental filtering and as such does not depend on any precomputation, thus allowing interactive explorations of volumetric data sets via on-the-fly editing of the shading model parameters or (multi-dimensional) transfer functions. © 2011 The Author(s).

  13. Mixed convection in a nanofluid filled-cavity with partial slip subjected to constant heat flux and inclined magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Ismael, Muneer A. [Mechanical Engineering Department, Engineering College, University of Basrah, Basrah (Iraq); Mansour, M.A. [Department of Mathematics, Assuit University, Faculty of Science, Assuit (Egypt); Chamkha, Ali J. [Mechanical Engineering Department, Prince Mohammad Bin Fahd University, Al-Khobar 31952 (Saudi Arabia); Prince Sultan Endowment for Energy and Environment, Prince Mohammad Bin Fahd University, Al-Khobar 31952 (Saudi Arabia); Rashad, A.M., E-mail: am_rashad@yahoo.com [Department of Mathematics, Aswan University, Faculty of Science, Aswan 81528 (Egypt)

    2016-10-15

    Mixed convection in a lid-driven square cavity filled with Cu-water nanofluid and subjected to inclined magnetic field is investigated in this paper. Partial slip effect is considered along the lid driven horizontal walls. A constant heat flux source on the left wall is considered, meanwhile the right vertical wall is cooled isothermally. The remainder cavity walls are thermally insulted. A control finite volume method is used as a numerical appliance of the governing equations. Six pertinent parameters were studied these; the orientation of the magnetic field (Φ=0–360°), Richardson number (Ri=0.001–1000), Hartman number (Ha=0–100), the size and position of the heat source (B=0.2–0.8, D=0.3–0.7, respectively), nanoparticles volume fraction (ϕ=0.0–0.1), and the lid-direction of the horizontal walls (λ=±1) where the positive sign means lid-driven to the right while the negative sign means lid-driven to the left. The results show that the orientation and the strength of the magnetic field can play a significant role in controlling the convection under the effect of partial slip. It is also found that the natural convection decreases with increasing the length of the heat source for all ranges of the studied parameters, while it is do so due to the vertical distance up to Hartman number of 50, beyond this value the natural convection decreases with lifting the heat source narrower to the top wall. - Highlights: • Partial slip along moving walls of MHD cavity filled with nanofluid is considered. • The suppression exerted by the magnetic field decreases with its orientation. • Nusselt number is enhanced slightly with nanoparticles at shortest heat source. • Nusselt number is enhanced with nanoparticles at stronger magnetic field.

  14. Mixed convection in a nanofluid filled-cavity with partial slip subjected to constant heat flux and inclined magnetic field

    International Nuclear Information System (INIS)

    Ismael, Muneer A.; Mansour, M.A.; Chamkha, Ali J.; Rashad, A.M.

    2016-01-01

    Mixed convection in a lid-driven square cavity filled with Cu-water nanofluid and subjected to inclined magnetic field is investigated in this paper. Partial slip effect is considered along the lid driven horizontal walls. A constant heat flux source on the left wall is considered, meanwhile the right vertical wall is cooled isothermally. The remainder cavity walls are thermally insulted. A control finite volume method is used as a numerical appliance of the governing equations. Six pertinent parameters were studied these; the orientation of the magnetic field (Φ=0–360°), Richardson number (Ri=0.001–1000), Hartman number (Ha=0–100), the size and position of the heat source (B=0.2–0.8, D=0.3–0.7, respectively), nanoparticles volume fraction (ϕ=0.0–0.1), and the lid-direction of the horizontal walls (λ=±1) where the positive sign means lid-driven to the right while the negative sign means lid-driven to the left. The results show that the orientation and the strength of the magnetic field can play a significant role in controlling the convection under the effect of partial slip. It is also found that the natural convection decreases with increasing the length of the heat source for all ranges of the studied parameters, while it is do so due to the vertical distance up to Hartman number of 50, beyond this value the natural convection decreases with lifting the heat source narrower to the top wall. - Highlights: • Partial slip along moving walls of MHD cavity filled with nanofluid is considered. • The suppression exerted by the magnetic field decreases with its orientation. • Nusselt number is enhanced slightly with nanoparticles at shortest heat source. • Nusselt number is enhanced with nanoparticles at stronger magnetic field.

  15. Effects of Contrast Agent and Outer Volume Saturation Bands on Water Suppression and Shimming of Hepatic Single-Volume Proton MR Spectroscopy at 3.0T

    Directory of Open Access Journals (Sweden)

    Li Xu

    2012-01-01

    Full Text Available Purpose. To determine whether administration of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA and whether placement of the outer volume saturation bands significantly affect shimming and water suppression on hepatic MR spectroscopic prescanning. Method. Region of interest (ROI of 2 cm × 2 cm × 2 cm was carefully positioned in the region of the middle portion of the right hepatic lobe. 32 patients were examined before and after administration of Gd-DTPA with and without outer-volume saturation bands. Linewidths (Full-Width Half-Maximum (FWHM and water suppression were obtained. A paired t-test for comparison of means was used. Results. (1 The group with the outer volume saturation bands demonstrated slightly better water suppression effect than the group without outer volume saturation bands before administration. (2 The group with the outer volume saturation bands demonstrated better water suppression effect than the group without outer volume saturation bands after administration. (3 Both shimming and water suppression effectswere decreased on enhanced MR spectroscopic prescanning (all P<0.05. Conclusions. Placement of the outer volume saturation bands is helpful to improve water suppression both before and after contrast agent administration. Gd-DTPA exerts a slightly adverse effect (a statistically significant but clinically unimportant on magnetic resonance spectroscopic prescanning at 3T.

  16. Effects of partial-body cryotherapy (- 110°C) on muscle recovery between high-intensity exercise bouts.

    Science.gov (United States)

    Ferreira-Junior, J B; Bottaro, M; Vieira, C A; Soares, S R S; Vieira, A; Cleto, V A; Cadore, E L; Coelho, D B; Simoes, H G; Brown, L E

    2014-12-01

    The aim of this study was to evaluate the effects of a single partial-body cryotherapy bout between training sessions on strength recovery. 12 young men (23.9±5.9 years) were randomly exposed to 2 different conditions separated by 7 days: 1) Partial-body cryotherapy (subjects were exposed to 3 min of partial-body cryotherapy at - 110 °C between 2 high-intensity training sessions); 2) Control (subjects were not exposed to partial-body cryotherapy between 2 high-intensity training sessions). Subjects were exposed to partial-body cryotherapy after the first training session. The 2 knee extension high-intensity training sessions were separated by a 40-min rest interval. Knee extension training consisted of 6 sets of 10 repetitions at 60°.s(-1) for concentric actions and 6 sets of 10 at 180.s(-1) for eccentric actions. The decrease in eccentric peak torque and total work was significantly (pcryotherapy (5.6 and 2%, respectively) when compared to control (16 and 11.6%, respectively). However, the decrease in concentric peak torque and total work was not different (p>0.05) between partial-body cryotherapy (9.4 and 6.5%, respectively) and control (7.5 and 5.2%, respectively). These results indicate that the use of partial-body cryotherapy between-training sessions can enhance eccentric muscle performance recovery. © Georg Thieme Verlag KG Stuttgart · New York.

  17. A Prospective Pathologic Study to Define the Clinical Target Volume for Partial Breast Radiation Therapy in Women With Early Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Brandon T., E-mail: Brandon.Nguyen@act.gov.au [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Canberra Hospital, Radiation Oncology Department, Garran, ACT (Australia); Deb, Siddhartha [Department of Anatomical Pathology, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Victorian Cancer Biobank, Cancer Council of Victoria, Carlton, Victoria (Australia); Fox, Stephen [Department of Anatomical Pathology, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Hill, Prudence [Department of Anatomical Pathology, St. Vincent' s Hospital Melbourne, Fitzroy, Victoria (Australia); Collins, Marnie [Centre for Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Chua, Boon H. [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); University of Melbourne, Parkville, Victoria (Australia)

    2012-12-01

    Purpose: To determine an appropriate clinical target volume for partial breast radiation therapy (PBRT) based on the spatial distribution of residual invasive and in situ carcinoma after wide local excision (WLE) for early breast cancer or ductal carcinoma in situ (DCIS). Methods and Materials: We performed a prospective pathologic study of women potentially eligible for PBRT who had re-excision and/or completion mastectomy after WLE for early breast cancer or DCIS. A pathologic assessment protocol was used to determine the maximum radial extension (MRE) of residual carcinoma from the margin of the initial surgical cavity. Women were stratified by the closest initial radial margin width: negative (>1 mm), close (>0 mm and {<=}1 mm), or involved. Results: The study population was composed of 133 women with a median age of 59 years (range, 27-82 years) and the following stage groups: 0 (13.5%), I (40.6%), II (38.3%), and III (7.5%). The histologic subtypes of the primary tumor were invasive ductal carcinoma (74.4%), invasive lobular carcinoma (12.0%), and DCIS alone (13.5%). Residual carcinoma was present in the re-excision and completion mastectomy specimens in 55.4%, 14.3%, and 7.2% of women with an involved, close, and negative margin, respectively. In the 77 women with a noninvolved radial margin, the MRE of residual disease, if present, was {<=}10 mm in 97.4% (95% confidence interval 91.6-99.5) of cases. Larger MRE measurements were significantly associated with an involved margin (P<.001), tumor size >30 mm (P=.03), premenopausal status (P=.03), and negative progesterone receptor status (P=.05). Conclusions: A clinical target volume margin of 10 mm would encompass microscopic residual disease in >90% of women potentially eligible for PBRT after WLE with noninvolved resection margins.

  18. A Prospective Pathologic Study to Define the Clinical Target Volume for Partial Breast Radiation Therapy in Women With Early Breast Cancer

    International Nuclear Information System (INIS)

    Nguyen, Brandon T.; Deb, Siddhartha; Fox, Stephen; Hill, Prudence; Collins, Marnie; Chua, Boon H.

    2012-01-01

    Purpose: To determine an appropriate clinical target volume for partial breast radiation therapy (PBRT) based on the spatial distribution of residual invasive and in situ carcinoma after wide local excision (WLE) for early breast cancer or ductal carcinoma in situ (DCIS). Methods and Materials: We performed a prospective pathologic study of women potentially eligible for PBRT who had re-excision and/or completion mastectomy after WLE for early breast cancer or DCIS. A pathologic assessment protocol was used to determine the maximum radial extension (MRE) of residual carcinoma from the margin of the initial surgical cavity. Women were stratified by the closest initial radial margin width: negative (>1 mm), close (>0 mm and ≤1 mm), or involved. Results: The study population was composed of 133 women with a median age of 59 years (range, 27-82 years) and the following stage groups: 0 (13.5%), I (40.6%), II (38.3%), and III (7.5%). The histologic subtypes of the primary tumor were invasive ductal carcinoma (74.4%), invasive lobular carcinoma (12.0%), and DCIS alone (13.5%). Residual carcinoma was present in the re-excision and completion mastectomy specimens in 55.4%, 14.3%, and 7.2% of women with an involved, close, and negative margin, respectively. In the 77 women with a noninvolved radial margin, the MRE of residual disease, if present, was ≤10 mm in 97.4% (95% confidence interval 91.6-99.5) of cases. Larger MRE measurements were significantly associated with an involved margin (P 30 mm (P=.03), premenopausal status (P=.03), and negative progesterone receptor status (P=.05). Conclusions: A clinical target volume margin of 10 mm would encompass microscopic residual disease in >90% of women potentially eligible for PBRT after WLE with noninvolved resection margins.

  19. Partially-deuterated samples of HET-s(218–289) fibrils: assignment and deuterium isotope effect

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Albert A.; Ravotti, Francesco; Testori, Emilie; Cadalbert, Riccardo; Ernst, Matthias, E-mail: maer@ethz.ch [ETH Zürich, Physical Chemistry (Switzerland); Böckmann, Anja, E-mail: a.bockmann@ibcp.fr [Institut de Biologie et Chimie des Protéines, Bases Moléculaires et Structurales des Systèmes Infectieux, Labex Ecofect, UMR 5086 CNRS, Université de Lyon (France); Meier, Beat H., E-mail: beme@ethz.ch [ETH Zürich, Physical Chemistry (Switzerland)

    2017-02-15

    Fast magic-angle spinning and partial sample deuteration allows direct detection of {sup 1}H in solid-state NMR, yielding significant gains in mass sensitivity. In order to further analyze the spectra, {sup 1}H detection requires assignment of the {sup 1}H resonances. In this work, resonance assignments of backbone H{sup N} and Hα are presented for HET-s(218–289) fibrils, based on the existing assignment of Cα, Cβ, C’, and N resonances. The samples used are partially deuterated for higher spectral resolution, and the shifts in resonance frequencies of Cα and Cβ due to the deuterium isotope effect are investigated. It is shown that the deuterium isotope effect can be estimated and used for assigning resonances of deuterated samples in solid-state NMR, based on known resonances of the protonated protein.

  20. Assessing the relationship between latent inhibition and the partial reinforcement extinction effect in autoshaping with rats.

    Science.gov (United States)

    Boughner, Robert L; Papini, Mauricio R

    2008-05-01

    Results from a variety of independently run experiments suggest that latent inhibition (LI) and the partial reinforcement extinction effect (PREE) share underlying mechanisms. Experiment 1 tested this LI=PREE hypothesis by training the same set of rats in situations involving both nonreinforced preexposure to the conditioned stimulus (LI stage) and partial reinforcement training (PREE stage). Control groups were also included to assess both LI and the PREE. The results demonstrated a significant, but negative correlation between the size of the LI effect and that of the PREE. Experiment 2 extended this analysis to the effects on LI and the PREE of the anxiolytic benzodiazepine chlordiazepoxide (5 mg/kg, i.p.). Whereas chlordiazepoxide had no effect on LI, it delayed the onset of the PREE. No evidence in support of the LI=PREE hypothesis was obtained when these two learning phenomena were compared within the same experiment and under the same general conditions of training.

  1. Phase equilibria and excess molar volumes of tetrahydrofuran (1) + deuterium oxide (2)

    International Nuclear Information System (INIS)

    Lejcek, P.; Matous, J.; Novak, J.P.; Pick, J.

    1975-01-01

    Vapour + liquid equilibrium at 313.15 and 333.15K, liquid + liquid equilibrium throughout the whole region of limited miscibility, and excess molar volumes at 298.15K have been studied for tetrahydrofuran + deuterium oxide. The mixtures show large positive deviations from Raoult's law and a closed loop of limited miscibility. The modified Redlich-Kister equation has been used for the correlation of the vapour + liquid equilibrium. The computation has been carried out according to a recently proposed procedure which makes it possible to obtain such constants of the correlation relation which are not inconsistent with physical reality, i.e. with the complete miscibility (partial delta 2 G/deltax 1 2 >0) under experimental conditions. Thermodynamic consistency was checked by the classical Redlich-Kister test and the one proposed by Ulrichson and Stevenson. Excess molar volumes are negative at all compositions with a point of inflexion in the water-rich region which indicates the extremes in partial molar volumes. (author)

  2. Effects of quenching and partial quenching on QCD penguin matrix elements

    NARCIS (Netherlands)

    Golterman, Maarten; Pallante, Elisabetta

    2002-01-01

    We point out that chiral transformation properties of penguin operators change in the transition from unquenched to (partially) quenched QCD. The way in which this affects the lattice determination of weak matrix elements can be understood in the framework of (partially) quenched chiral perturbation

  3. The effect of deformation mode on the sensitisation of partially martensitic stainless steels

    International Nuclear Information System (INIS)

    Briant, C.L.

    1981-01-01

    The metallurgical process by which austenitic stainless steels become susceptible to corrosion is defined as sensitisation. It is now well established that if the austenite is partially transformed to martensite by deformation, the kinetics of sensitisation will be accelerated. In this paper the effects of martensite induced by various deformation modes on sensitisation are examined. It will be shown that in all cases the martensite accelerates sensitisation which in turn leads to rapid corrosion. This effect is independent of the way the martensite is induced. The results also show that this effect is observed over a wide range of martensite content. (author)

  4. A novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography

    Energy Technology Data Exchange (ETDEWEB)

    Santini, M., E-mail: maurizio.santini@unibg.it [Department of Engineering and Applied Sciences, University of Bergamo, Bergamo (Italy); Guilizzoni, M. [Department of Energy, Politecnico di Milano, Milano (Italy); Fest-Santini, S. [Department of Engineering, University of Bergamo, Bergamo (Italy); Lorenzi, M. [School of Engineering and Mathematical Sciences, City University London, London (United Kingdom)

    2015-02-15

    An experimental study about the anisotropic wetting behavior of a surface patterned with parallel grooves is presented as an application example of a novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography. Shape of glycerin droplets on such surface is investigated by X-ray micro computed tomography (microCT) acting as a non-intrusive, full volume 3D microscope with micrometric spatial resolution. The reconstructed drop volumes enable to estimate the exact volumes of the drops, their base contours, and 3D static contact angles, based on true cross-sections of the drop-surface couple. Droplet base contours are compared to approximate geometrical contour shapes proposed in the literature. Contact angles along slices parallel and perpendicular to the grooves direction are compared with each other. The effect of the sessile drop volume on the wetting behavior is discussed. The proposed technique, which is applicable for any structured surface, enables the direct measure of Wenzel ratio based on the microCT scan in the wetted region usually inapproachable by any others. Comparisons with simplified models are presented and congruence of results with respect to the minimum resolution needed is evaluated and commented.

  5. Pancharatnam geometric phase originating from successive partial ...

    Indian Academy of Sciences (India)

    Pancharatnam connection [1,2] dictates that ψp is in phase ψ0. The partial projection effects a ... up to a real multiplier. Here again, ψf is in phase with ψp but relative to ψ0, has a .... For the third partial projection of strength t3 and an azimuth angle φ13 to effect a triangle closure for both initial states |z〉 and | − z〉, we derive ...

  6. Volume ignition of laser driven fusion pellets and double layer effects

    International Nuclear Information System (INIS)

    Cicchitelli, L.; Eliezer, S.; Goldsworthy, M.P.; Green, F.; Hora, H.; Ray, P.S.; Stening, R.J.; Szichman, H.

    1988-01-01

    The realization of an ideal volume compression of laser-irradiated fusion pellets opens the possibility for an alternative to spark ignition proposed for many years for inertial confinement fusion. A re-evaluation of the difficulties of the central spark ignition of laser driven pellets is given. The alternative volume compression theory, together with volume burn and volume ignition, have received less attention and are re-evaluated in view of the experimental verification generalized fusion gain formulas, and the variation of optimum temperatures derived at self-ignition. Reactor-level DT fusion with MJ-laser pulses and volume compression to 50 times the solid-state density are estimated. Dynamic electric fields and double layers at the surface and in the interior of plasmas result in new phenomena for the acceleration of thermal electrons to suprathermal electrons. Double layers also cause a surface tension which stabilizes against surface wave effects and Rayleigh-Taylor instabilities. (author)

  7. Symmetric geometric transfer matrix partial volume correction for PET imaging: principle, validation and robustness

    Science.gov (United States)

    Sattarivand, Mike; Kusano, Maggie; Poon, Ian; Caldwell, Curtis

    2012-11-01

    Limited spatial resolution of positron emission tomography (PET) often requires partial volume correction (PVC) to improve the accuracy of quantitative PET studies. Conventional region-based PVC methods use co-registered high resolution anatomical images (e.g. computed tomography (CT) or magnetic resonance images) to identify regions of interest. Spill-over between regions is accounted for by calculating regional spread functions (RSFs) in a geometric transfer matrix (GTM) framework. This paper describes a new analytically derived symmetric GTM (sGTM) method that relies on spill-over between RSFs rather than between regions. It is shown that the sGTM is mathematically equivalent to Labbe's method; however it is a region-based method rather than a voxel-based method and it avoids handling large matrices. The sGTM method was validated using two three-dimensional (3D) digital phantoms and one physical phantom. A 3D digital sphere phantom with sphere diameters ranging from 5 to 30 mm and a sphere-to-background uptake ratio of 3-to-1 was used. A 3D digital brain phantom was used with four different anatomical regions and a background region with different activities assigned to each region. A physical sphere phantom with the same geometry and uptake as the digital sphere phantom was manufactured and PET-CT images were acquired. Using these three phantoms, the performance of the sGTM method was assessed against that of the GTM method in terms of accuracy, precision, noise propagation and robustness. The robustness was assessed by applying mis-registration errors and errors in estimates of PET point spread function (PSF). In all three phantoms, the results showed that the sGTM method has accuracy similar to that of the GTM method and within 5%. However, the sGTM method showed better precision and noise propagation than the GTM method, especially for spheres smaller than 13 mm. Moreover, the sGTM method was more robust than the GTM method when mis-registration errors or

  8. Symmetric geometric transfer matrix partial volume correction for PET imaging: principle, validation and robustness

    International Nuclear Information System (INIS)

    Sattarivand, Mike; Caldwell, Curtis; Kusano, Maggie; Poon, Ian

    2012-01-01

    Limited spatial resolution of positron emission tomography (PET) often requires partial volume correction (PVC) to improve the accuracy of quantitative PET studies. Conventional region-based PVC methods use co-registered high resolution anatomical images (e.g. computed tomography (CT) or magnetic resonance images) to identify regions of interest. Spill-over between regions is accounted for by calculating regional spread functions (RSFs) in a geometric transfer matrix (GTM) framework. This paper describes a new analytically derived symmetric GTM (sGTM) method that relies on spill-over between RSFs rather than between regions. It is shown that the sGTM is mathematically equivalent to Labbe's method; however it is a region-based method rather than a voxel-based method and it avoids handling large matrices. The sGTM method was validated using two three-dimensional (3D) digital phantoms and one physical phantom. A 3D digital sphere phantom with sphere diameters ranging from 5 to 30 mm and a sphere-to-background uptake ratio of 3-to-1 was used. A 3D digital brain phantom was used with four different anatomical regions and a background region with different activities assigned to each region. A physical sphere phantom with the same geometry and uptake as the digital sphere phantom was manufactured and PET-CT images were acquired. Using these three phantoms, the performance of the sGTM method was assessed against that of the GTM method in terms of accuracy, precision, noise propagation and robustness. The robustness was assessed by applying mis-registration errors and errors in estimates of PET point spread function (PSF). In all three phantoms, the results showed that the sGTM method has accuracy similar to that of the GTM method and within 5%. However, the sGTM method showed better precision and noise propagation than the GTM method, especially for spheres smaller than 13 mm. Moreover, the sGTM method was more robust than the GTM method when mis-registration errors or

  9. Hydro-isomerization of n-hexane on bi-functional catalyst: Effect of total and hydrogen partial pressures

    Science.gov (United States)

    Thoa, Dao Thi Kim; Loc, Luu Cam

    2017-09-01

    The effect of both total pressure and hydrogen partial pressure during n-hexane hydro-isomerization over platinum impregnated on HZSM-5 was studied. n-Hexane hydro-isomerization was conducted at atmospheric pressure and 0.7 MPa to observe the influence of total pressure. In order to see the effect of hydrogen partial pressure, the reaction was taken place at different partial pressure of hydrogen varied from 307 hPa to 718 hPa by dilution with nitrogen to keep the total pressure at 0.1 MPa. Physico-chemical characteristics of catalyst were determined by the methods of nitrogen physi-sorption BET, SEM, XRD, TEM, NH3-TPD, TPR, and Hydrogen Pulse Chemi-sorption. Activity of catalyst in the hydro-isomerization of n-hexane was studied in a micro-flow reactor in the temperature range of 225-325 °C; the molar ratio H2/ hydrocarbon: 5.92, concentration of n-hexane: 9.2 mol.%, GHSV 2698 h-1. The obtained catalyst expressed high acid density, good reducing property, high metal dispersion, and good balance between metallic and acidic sites. It is excellent contact for n-hexane hydro-isomerization. At 250 °C, n-hexane conversion and selectivity were as high as 59-76 % and 85-99 %, respectively. It was found that catalytic activity was promoted either by total pressure or hydrogen partial pressure. At total pressure of 0.7 MPa while hydrogen partial pressure of 718 hPa, catalyst produced 63 RON liquid product containing friendly environmental iso-paraffins which is superior blending stock for green gasoline. Hydrogen did not only preserve catalyst actives by depressing hydrocracking and removing coke precursors but also facilitated hydride transfer step in the bi-functional bi-molecular mechanism.

  10. Measurement and correlation of excess molar volumes for mixtures of 1-propanol and aromatic hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Gahlyan, Suman; Rani, Manju; Maken, Sanjeev Kumar [Deenbandhu Chhotu Ram University of Science and Technology, Murthal (India); Lee, Inkyu; Moon, Il [Yonsei University, Seoul (Korea, Republic of)

    2015-01-15

    Excess molar volumes (V{sub m}{sup E} ) have been measured at 303.15 K for 1-propanol+benzene or toluene or o- or m- or p-xylene mixtures using V-shape dilatometer. The V{sub m}{sup E} values, for an equimolar composition, vary in the order: benzene>toluene-m-xylene>o-xylene>p-xylene. The V{sub m}{sup E} data have been used to calculate partial molar volumes, excess partial molar volumes, and apparent molar volumes of 1-propanol and aromatic hydrocarbons over the entire range of composition. The excess volume data have also been interpreted in terms of graph-theoretical approach and Prigogine-Flory-Patterson theory (PFP). While PFP theory fails to predict the V{sub m}{sup E} values for systems with s-shaped V{sub m}{sup E} versus x{sub 1} graph, the V{sub m}{sup E} values calculated by graph theory compare reasonably well with the corresponding experimental values. This graph theory analysis has further yielded information about the state of aggregation of pure components as well as of the mixtures.

  11. Volumizing effects of a smooth, highly cohesive, viscous 20-mg/mL hyaluronic acid volumizing filler: prospective European study

    Directory of Open Access Journals (Sweden)

    Hoffmann Klaus

    2009-08-01

    Full Text Available Abstract Background Facial volume loss contributes significantly to facial aging. The 20-mg/mL hyaluronic acid (HA formulation used in this study is a smooth, highly cohesive, viscous, fully reversible, volumizing filler indicated to restore facial volume. This first prospective study evaluated use in current aesthetic clinical practice. Methods A pan-European evaluation conducted under guidelines of the World Association of Opinion and Marketing Research, the trial comprised a baseline visit (visit 1 and a follow-up (visit 2 at 14 ± 7 days posttreatment. Physicians photographed patients at each visit. Each patient was treated with the 20-mg/mL HA volumizing filler as supplied in standard packaging. Procedural details, aesthetic outcomes, safety, and physician and patient ratings of their experience were recorded. Results Fifteen physicians and 70 patients (91% female; mean age: 50 years participated. Mean volume loss at baseline was 3.7 (moderate on the Facial Volume Loss Scale. Local anesthesia was used in 64.3% of cases. Most injections (85% were administered with needles rather than cannulas. Of the 208 injections, 59% were in the malar region, primarily above the periosteum. Subcutaneous injections were most common for other sites. The mean total injection volume per patient was 4.6 mL. The mean volume loss score declined significantly (P Conclusion The 20-mg/mL smooth, highly cohesive, viscous, volumizing HA filler was effective, well tolerated, and easy to use in current clinical practice. Participants were very likely to recommend this product to colleagues and friends, and patients would be very or quite likely to request this product for future treatments.

  12. Dielectric response of fully and partially depleted ferroelectric thin films and inversion of the thickness effect

    International Nuclear Information System (INIS)

    Misirlioglu, I B; Yildiz, M

    2013-01-01

    We study the effect of full and partial depletion on the dielectric response characteristics of ferroelectric thin films with impurities via a computational approach. Using a thermodynamic approach along with the fundamental equations for semiconductors, we show that films with partial depletion display unique features and an enhanced dielectric response compared with those fully depleted. We find that the capacitance peak at switching can be significantly suppressed in the case of high impurity densities (>10 25 m −3 ) with relatively low ionization energy, of the order of 0.5 eV. For conserved number of species in films, electromigration of ionized impurities at room temperature is negligible and has nearly no effect on the dielectric response. In films with high impurity density, the dielectric response at zero bias is enhanced with respect to charge-free films or those with relatively low impurity density ( 24 m −3 ). We demonstrate that partially depleted films should be expected to exhibit peculiar capacitance–voltage characteristics at low and high bias and that the thickness effect probed in experiments in ferroelectric thin films could be entirely inverted in thin films with depletion charges where a higher dielectric response can be measured in thicker films. Therefore, depletion charge densities in ferroelectric thin films should be estimated before size-effect-related studies. Finally, we noted that these findings are in good qualitative agreement with dielectric measurements carried out on PbZr x Ti 1−x O 3 . (paper)

  13. Increased putamen volume in adults with autism spectrum disorder

    Directory of Open Access Journals (Sweden)

    Wataru eSato

    2014-11-01

    Full Text Available Basal ganglia (BG abnormalities are implicated in the pathophysiology of autism spectrum disorder (ASD. However, studies measuring the volume of the entire BG in individuals with ASD have reported discrepant findings, and no study conducted volume measurement of the entire substructures of the BG (the caudate, putamen, nucleus accumbens, and globus pallidus in individuals with ASD. We delineated the BG substructures and measured their volumes in 29 adults with ASD without intellectual disabilities and 29 age- and gender-matched typically developed adult controls. We acquired T1-weighted anatomical images and performed semi-automated delineation and volume measurements of the above-mentioned subregions. Total cerebral volumes, sex, and ages were partialed out. Compared with controls, the putamen was significantly larger in the ASD group. The increased volume of the putamen found in high-functioning adults with ASD suggests that structural or histological abnormalities of the putamen may underlie the pathologies of ASD such as repetitive and stereotyped behaviors and impaired social interactions.

  14. Effects of ionizing radiation and partial hepatectomy on messenger RNA synthesis

    International Nuclear Information System (INIS)

    Abdel-Halim, M.N.

    1979-01-01

    Newly synthesized messenger RNA, as measured by a 40 min uptake of the radioactive precursor (6- 14 C) orotic acid, was studied in the regenerating livers of non-irradiated and gamma-irradiated (1800 rad) adrenal-intact and adrenalectomized rats 24 and 48 hours after partial hepatectomy. Two groups of rats, one with and one without adrenal glands were each divided into four subgroups: (1) control rats, (2) irradiated rats, (3) partially hepatectomized rats and (4) irradiated, partially hepatectomized rats. The radioactive profile of polyribosome formation and distribution was determined by sucrose density gradient centrifugation (10 to 40 per cent). The result of this study indicates that ionizing radiation decreases the synthesis of newly formed messenger RNA in regenerating livers of adrenal-intact rats. However, adrenalectomy largely abolished that inhibition. These data suggest that the decrease in messenger RNA synthesis may be explained by the disturbance of adrenal hormones induced by partial hepatectomy and ionizing radiation. (author)

  15. Numerical study of three-dimensional natural convection and entropy generation in a cubical cavity with partially active vertical walls

    Directory of Open Access Journals (Sweden)

    Abdullah A.A.A Al-Rashed

    2017-09-01

    Full Text Available Natural convection and entropy generation due to the heat transfer and fluid friction irreversibilities in a three-dimensional cubical cavity with partially heated and cooled vertical walls has been investigated numerically using the finite volume method. Four different arrangements of partially active vertical sidewalls of the cubical cavity are considered. Numerical calculations are carried out for Rayleigh numbers from (103 ≤ Ra ≤ 106, various locations of the partial heating and cooling vertical sidewalls, while the Prandtl number of air is considered constant as Pr=0.7 and the irreversibility coefficient is taken as (φ=10−4. The results explain that the total entropy generation rate increases when the Rayleigh number increases. While, the Bejan number decreases as the Rayleigh number increases. Also, it is found that the arrangements of heating and cooling regions have a significant effect on the fluid flow and heat transfer characteristics of natural convection and entropy generation in a cubical cavity. The Middle-Middle arrangement produces higher values of average Nusselt numbers.

  16. Physiological and biochemical principles underlying volume-targeted therapy--the "Lund concept".

    Science.gov (United States)

    Nordström, Carl-Henrik

    2005-01-01

    The optimal therapy of sustained increase in intracranial pressure (ICP) remains controversial. The volume-targeted therapy ("Lund concept") discussed in this article focuses on the physiological volume regulation of the intracranial compartments. The balance between effective transcapillary hydrostatic and osmotic pressures constitutes the driving force for transcapillary fluid exchange. The low permeability for sodium and chloride combined with the high crystalloid osmotic pressure (approximately 5700 mmHg) on both sides of the blood-brain barrier (BBB) counteracts fluid exchange across the intact BBB. Additionally, variations in systemic blood pressure generally are not transmitted to these capillaries because cerebral intracapillary hydrostatic pressure (and blood flow) is physio-logically tightly autoregulated. Under pathophysiological conditions, the BBB may be partially disrupted. Transcapillary water exchange is then determined by the differences in hydrostatic and colloid osmotic pressure between the intra- and extracapillary compartments. Pressure autoregulation of cerebral blood flow is likely to be impaired in these conditions. A high cerebral perfusion pressure accordingly increases intracapillary hydrostatic pressure and leads to increased intracerebral water content and an increase in ICP. The volume-targeted "Lund concept" has been evaluated in experimental and clinical studies to examine the physiological and biochemical (utilizing intracerebral microdialysis) effects, and the clinical experiences have been favorable.

  17. Partial-Body Irradiation in Patients with Prostate Cancer Treated with IMRT Has Little Effect on the Composition of Serum Proteome.

    Science.gov (United States)

    Pietrowska, Monika; Jelonek, Karol; Polanska, Joanna; Wojakowska, Anna; Marczak, Lukasz; Chawinska, Ewa; Chmura, Aleksanda; Majewski, Wojciech; Miszczyk, Leszek; Widlak, Piotr

    2015-06-30

    Partial body irradiation during cancer radiotherapy (RT) induces a response of irradiated tissues that could be observed at the level of serum proteome. Here we aimed to characterize the response to RT in group of patients treated because of prostate cancer. Five consecutive blood samples were collected before, during, and after the end of RT in a group of 126 patients who received definitive treatment with a maximum dose of 76 Gy. Serum peptidome, which was profiled in the 2000-16,000 Da range using MALDI-MS. Serum proteins were identified and quantified using the shotgun LC-MS/MS approach. The majority of changes in serum peptidome were detected between pre-treatment samples and samples collected after 3-4 weeks of RT (~25% of registered peptides changed their abundances significantly), yet the intensity of observed changes was not correlated significantly with the degree of acute radiation toxicity or the volume of irradiated tissues. Furthermore, there were a few serum proteins identified, the abundances of which were different in pre-RT and post-RT samples, including immunity and inflammation-related factors. Observed effects were apparently weaker than in comparable groups of head and neck cancer patients in spite of similar radiation doses and volumes of irradiated tissues in both groups. We concluded that changes observed at the level of serum proteome were low for this cohort of prostate cancer patients, although the specific components involved are associated with immunity and inflammation, and reflect the characteristic acute response of the human body to radiation.

  18. Partial-Body Irradiation in Patients with Prostate Cancer Treated with IMRT Has Little Effect on the Composition of Serum Proteome

    Directory of Open Access Journals (Sweden)

    Monika Pietrowska

    2015-06-01

    Full Text Available Partial body irradiation during cancer radiotherapy (RT induces a response of irradiated tissues that could be observed at the level of serum proteome. Here we aimed to characterize the response to RT in group of patients treated because of prostate cancer. Five consecutive blood samples were collected before, during, and after the end of RT in a group of 126 patients who received definitive treatment with a maximum dose of 76 Gy. Serum peptidome, which was profiled in the 2000–16,000 Da range using MALDI-MS. Serum proteins were identified and quantified using the shotgun LC-MS/MS approach. The majority of changes in serum peptidome were detected between pre-treatment samples and samples collected after 3–4 weeks of RT (~25% of registered peptides changed their abundances significantly, yet the intensity of observed changes was not correlated significantly with the degree of acute radiation toxicity or the volume of irradiated tissues. Furthermore, there were a few serum proteins identified, the abundances of which were different in pre-RT and post-RT samples, including immunity and inflammation-related factors. Observed effects were apparently weaker than in comparable groups of head and neck cancer patients in spite of similar radiation doses and volumes of irradiated tissues in both groups. We concluded that changes observed at the level of serum proteome were low for this cohort of prostate cancer patients, although the specific components involved are associated with immunity and inflammation, and reflect the characteristic acute response of the human body to radiation.

  19. Effect of oxygen partial pressure on oxidation of Mo-metal

    Science.gov (United States)

    Sharma, Rabindar Kumar; Kumar, Prabhat; Singh, Megha; Gopal, Pawar; Reddy, G. B.

    2018-05-01

    This report explains the effect of oxygen partial pressure (PO2 ) on oxidation of Mo-metal in oxygen plasma. XRD results indulge that oxide layers formed on Mo-surfaces at different oxygen partial pressures have two different oxide phases (i.e. orthorhombic MoO3 and monoclinic Mo8O23). Intense XRD peaks at high pressure (i.e. 2.0×10-1 Torr) points out the formation of thick oxide layer on Mo-surface due to presence of large oxygen species in chamber and less oxide volatilization. Whereas, at low PO2 (6.5×10-2 and 7.5×10-2 Torr.) the reduced peak strength is owing to high oxide volatilization rate. SEM micrographs and thickness measurements also support XRD results and confirm that the optimum -2value of PO2 to deposited thicker and uniform oxide film on glass substrate is 7.5×10-2 Torr through plasma assistedoxidation process. Further to study the compositional properties, EDX of the sample M2 (the best sample) is carried out, which confirms that the stoichiometric ratio is less than 3 (i.e. 2.88). Less stoichiometric ratio again confirms the presence of sub oxides in oxide layers on Mo metal as evidenced by XRD results. All the observed results are well in consonance with each other.

  20. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke (Toyama Medical and Pharmaceutical Univ. (Japan))

    1993-09-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author).

  1. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke [Toyama Medical and Pharmaceutical Univ. (Japan)

    1993-09-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author).

  2. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    International Nuclear Information System (INIS)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke

    1993-01-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author)

  3. Dissociation of the effects of preload volume and energy content on subjective appetite and food intake.

    Science.gov (United States)

    Gray, Richard; French, Stephen; Robinson, Tristan; Yeomans, Martin

    2002-05-01

    Previous research suggests that enhancing the volume of a food preload without altering energy content can result in reduced appetite, although the limited evidence means that the conditions under which this effect will occur are not yet clear. In the present study, we used a Universal Eating Monitor (UEM) to record test meal intake constantly, in parallel with appetite ratings, following soup-based preloads that varied both in volume (150 vs. 450 ml) and energy density (1.4 vs. 4.2 kJ/ml). Healthy young men (n=20) received four different preload conditions (repeated measures) followed by unlimited hot pasta test meals (interval 30 min). They completed appetite ratings during and after each laboratory session, and food diaries for the afternoon and evening following each session. Subjective appetite after the preloads was reduced by the high-volume preloads relative to low-volume preloads, with no difference between the two at each volume level. This indicates an effect of volume, but no effect of energy. Test meal intake in the high-volume, high-energy-density condition was reduced relative to the other conditions, which did not differ from one another. This indicates an effect of total energy, but no effect of volume. The dissociation between these different measures of appetite might be explained in terms of largely cognitive influences on subjective appetite between preload and test meal, contrasted with stronger physiological influences on actual intake during the test meal. With regard to previous studies, it is argued that food volume is more influential under circumstances where gastric volume is closer to its normal limits.

  4. The effectiveness of Pilates for partial anterior cruciate ligament injury.

    Science.gov (United States)

    Çelik, Derya; Turkel, Nilgun

    2017-08-01

    This study explored the effects of Pilates on the muscle strength, function, and instability of patients with partial anterior cruciate ligament (ACL) injuries in situations in which a non-surgical treatment option is preferred. Fifty participants 20-45 years of age who were diagnosed with isolated ACL injuries were included in the study. The participants were randomly assigned to either the Pilates exercise group (n = 24) or the control group (n = 26). The subjects in the Pilates exercise group performed basic mat exercises that focused on the muscle strength and flexibility of the lower limbs and core muscles during each class session, which met three times per week for 12 weeks. The control group did not receive any treatment or home exercise programme. All patients were evaluated using the Lysholm Knee Scale, the Cincinnati Knee Rating System, and isokinetic quadriceps and hamstring strength. Patient satisfaction regarding improvement in knee stability was assessed using the Global Rating of Change scale. The Pilates group experienced significant improvement over the control group as measured by the difference in quadriceps strength at 12 weeks (p = 0.03). Both groups showed some clinical change over time, but the Pilates group improved for all outcome measurements at the 12-week follow-up, and the control group only improved for functional outcomes. Patient satisfaction with the level of knee stability based on the Global Rating of Change scale was higher in the Pilates group than in the control group. Although both groups exhibited improvements in knee strength and functional outcomes, the results suggest that Pilates is a superior management approach over a control treatment for increasing quadriceps strength in participants with partial ACL injury. Pilates may provide clinicians a novel option when choosing a treatment for a partial ACL injury. Further study is needed to determine whether certain subgroups of individuals might achieve an added

  5. Apparent molar volumes and compressibilities of electrolytes and ions in γ-butyrolactone

    International Nuclear Information System (INIS)

    Krakowiak, Joanna; Wawer, Jarosław; Farmas, Aleksander

    2012-01-01

    Highlights: ► Density and speed of sound for salts solutions in γ-butyrolactone were measured. ► The apparent molar volumes and compressibilities have been determined. ► The limiting molar quantities are split into independent ionic contributions. ► These data are used to describe ion–solvent interactions. - Abstract: The densities of tetraphenylphosphonium bromide, sodium tetraphenylborate, lithium perchlorate, sodium perchlorate and lithium bromide in γ-butyrolactone at (288.15, 293.15, 298.15, 303.15, 308.15 and 313.15) K and speed of sound at 298.15 K have been measured. From these data apparent molar volumes V Φ at (288.15, 293.15, 298.15, 303.15, 308.15 and 313.15) K and the apparent molar isentropic compressibility K S,Φ , at T = 298.15 K of the salts have been determined. The apparent molar volumes and the apparent molar isentropic compressibilities were fitted to the Redlich, Rosenfeld and Mayer equation as well as to the Pitzer and Masson equations yielding infinite dilution data. The obtained limiting values have been used to estimate the ionic data of the standard partial molar volume and the standard partial isentropic compressibility in γ-butyrolactone solutions.

  6. Partial processing

    International Nuclear Information System (INIS)

    1978-11-01

    This discussion paper considers the possibility of applying to the recycle of plutonium in thermal reactors a particular method of partial processing based on the PUREX process but named CIVEX to emphasise the differences. The CIVEX process is based primarily on the retention of short-lived fission products. The paper suggests: (1) the recycle of fission products with uranium and plutonium in thermal reactor fuel would be technically feasible; (2) it would, however, take ten years or more to develop the CIVEX process to the point where it could be launched on a commercial scale; (3) since the majority of spent fuel to be reprocessed this century will have been in storage for ten years or more, the recycling of short-lived fission products with the U-Pu would not provide an effective means of making refabrication fuel ''inaccessible'' because the radioactivity associated with the fission products would have decayed. There would therefore be no advantage in partial processing

  7. Monotherapy for partial epilepsy: focus on levetiracetam

    Directory of Open Access Journals (Sweden)

    Antonio Gambardella

    2008-03-01

    Full Text Available Antonio Gambardella1,2, Angelo Labate1,2, Eleonora Colosimo1, Roberta Ambrosio1, Aldo Quattrone1,21Institute of Neurology, University Magna Græcia, Catanzaro, Italy; 2Institute of Neurological Sciences, National Research Council, Piano Lago di Mangone, Cosenza, ItalyAbstract: Levetiracetam (LEV, the S-enantiomer of alpha-ethyl-2-oxo-1-pyrollidine acetamide, is a recently licensed antiepileptic drug (AED for adjunctive therapy of partial seizures. Its mechanism of action is uncertain but it exhibits a unique profile of anticonvulsant activity in models of chronic epilepsy. Five randomized, double-blind, placebo-controlled trials enrolling adult or pediatric patients with refractory partial epilepsy have demonstrated the efficacy of LEV as adjunctive therapy, with a responder rate (≥50% reduction in seizure frequency of 28%–45%. Long-term efficacy studies suggest retention rates of 60% after one year, with 13% of patients seizure-free for 6 months of the study and 8% seizure-free for 1 year. More recent studies illustrated successful conversion to monotherapy in patients with refractory epilepsy, and its effectiveness as a single agent in partial epilepsy. LEV has also efficacy in generalized epilepsies. Adverse effects of LEV, including somnolence, lethargy, and dizziness, are generally mild and their occurrence rate seems to be not significantly different from that observed in placebo groups. LEV also has no clinically significant pharmacokinetic interactions with other AEDs, or with commonly prescribed medications. The combination of effective antiepileptic properties with a relatively mild adverse effect profile makes LEV an attractive therapy for partial seizures.Keywords: levetiracetam, partial epilepsy, antiepileptic drugs

  8. Separation of time-based and trial-based accounts of the partial reinforcement extinction effect.

    Science.gov (United States)

    Bouton, Mark E; Woods, Amanda M; Todd, Travis P

    2014-01-01

    Two appetitive conditioning experiments with rats examined time-based and trial-based accounts of the partial reinforcement extinction effect (PREE). In the PREE, the loss of responding that occurs in extinction is slower when the conditioned stimulus (CS) has been paired with a reinforcer on some of its presentations (partially reinforced) instead of every presentation (continuously reinforced). According to a time-based or "time-accumulation" view (e.g., Gallistel and Gibbon, 2000), the PREE occurs because the organism has learned in partial reinforcement to expect the reinforcer after a larger amount of time has accumulated in the CS over trials. In contrast, according to a trial-based view (e.g., Capaldi, 1967), the PREE occurs because the organism has learned in partial reinforcement to expect the reinforcer after a larger number of CS presentations. Experiment 1 used a procedure that equated partially and continuously reinforced groups on their expected times to reinforcement during conditioning. A PREE was still observed. Experiment 2 then used an extinction procedure that allowed time in the CS and the number of trials to accumulate differentially through extinction. The PREE was still evident when responding was examined as a function of expected time units to the reinforcer, but was eliminated when responding was examined as a function of expected trial units to the reinforcer. There was no evidence that the animal responded according to the ratio of time accumulated during the CS in extinction over the time in the CS expected before the reinforcer. The results thus favor a trial-based account over a time-based account of extinction and the PREE. This article is part of a Special Issue entitled: Associative and Temporal Learning. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Effects of Thyroid Hormone on Left Ventricular Volume and Function in Hyperthyroidism

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Koh, Chang Soon

    1983-01-01

    The purpose of this study is to investigate the effects of thyroid hormone on the left ventricular (LV) volume and function in man with untreated hyperthyroidism and to determine the effects of successful therapy for thyrotoxicosis on the ventricular pathophysiology. In the present study, equilibrium ralhianuclide cardiac angiography was performed and LV volume index, ejection phase indexes of LV performance, serum thyroid hormone levels and other hemodynamic parameters were measured in 28 normal subjects and 39 patients with hyperthyroidism before treatment and again every 4 weeks for the first 2 months after the initiation of effective therapy. The result obtained were as follows; 1) In the untreated hyperthyroid state heart rate, blood volume, cardiac index and stroke volume index (97±14 beats/min, 73.5±11.8 ml/kg, 6.9±1.4 l/min/m2 and 77.6±13.8 ml/m2, respectively) were increased significantly compared to those in normal control (74±12 beats/min, 65.6±14.8 ml/kg, 3.8±1.2 l/min/m2 and 56.6±13.2 ml/m2 respectively). (Mean±SD). 2) There was a significant increase in LV end-diastolic volume index in patients with hyperthyroidism (30.5±7.5 for hyperthyroid group compared to a normal control of 22.2±6.5; P<0.001), whereas end-systolic volume index remained unchanged 9.6±3.6 and 8.8±3.3 respectively. 3) In patients with hyperthyroidism, LV ejection fraction was 70.0±5.6%, fractional shortening 32.9±5.1%, mean velocity of circumferential fiber shortening (mean Vcf) 1.34±0.31 circ/sec and maximum ejection rate 3.47±0.80. All the ejection phase indexes were significantly greater than those in normal control (65.2±5.7%, 28.8±3.2%, 0.88±0.37 circ/sec and 2.27±0.50, respectively; p<0.001). 4) Effective therapy produced significant decrease in all the values of serum thyroid hormone concenrations (p<0.001), hemodynamic parameters (p<0.001), end-diastolic volume index (p<0.01) and ejection phase indexes of LV contractility in patients with hyperthyroidism

  10. 8th conference on Finite Volumes for Complex Applications

    CERN Document Server

    Omnes, Pascal

    2017-01-01

    This first volume of the proceedings of the 8th conference on "Finite Volumes for Complex Applications" (Lille, June 2017) covers various topics including convergence and stability analysis, as well as investigations of these methods from the point of view of compatibility with physical principles. It collects together the focused invited papers comparing advanced numerical methods for Stokes and Navier–Stokes equations on a benchmark, as well as reviewed contributions from internationally leading researchers in the field of analysis of finite volume and related methods, offering a comprehensive overview of the state of the art in the field. The finite volume method in its various forms is a space discretization technique for partial differential equations based on the fundamental physical principle of conservation, and recent decades have brought significant advances in the theoretical understanding of the method. Many finite volume methods preserve further qualitative or asymptotic properties, including m...

  11. Developmentally Sensitive Interaction Effects of Genes and the Social Environment on Total and Subcortical Brain Volumes.

    Directory of Open Access Journals (Sweden)

    Jennifer S Richards

    Full Text Available Smaller total brain and subcortical volumes have been linked to psychopathology including attention-deficit/hyperactivity disorder (ADHD. Identifying mechanisms underlying these alterations, therefore, is of great importance. We investigated the role of gene-environment interactions (GxE in interindividual variability of total gray matter (GM, caudate, and putamen volumes. Brain volumes were derived from structural magnetic resonance imaging scans in participants with (N = 312 and without ADHD (N = 437 from N = 402 families (age M = 17.00, SD = 3.60. GxE effects between DAT1, 5-HTT, and DRD4 and social environments (maternal expressed warmth and criticism; positive and deviant peer affiliation as well as the possible moderating effect of age were examined using linear mixed modeling. We also tested whether findings depended on ADHD severity. Deviant peer affiliation was associated with lower caudate volume. Participants with low deviant peer affiliations had larger total GM volumes with increasing age. Likewise, developmentally sensitive GxE effects were found on total GM and putamen volume. For total GM, differential age effects were found for DAT1 9-repeat and HTTLPR L/L genotypes, depending on the amount of positive peer affiliation. For putamen volume, DRD4 7-repeat carriers and DAT1 10/10 homozygotes showed opposite age relations depending on positive peer affiliation and maternal criticism, respectively. All results were independent of ADHD severity. The presence of differential age-dependent GxE effects might explain the diverse and sometimes opposing results of environmental and genetic effects on brain volumes observed so far.

  12. Developmentally Sensitive Interaction Effects of Genes and the Social Environment on Total and Subcortical Brain Volumes.

    Science.gov (United States)

    Richards, Jennifer S; Arias Vásquez, Alejandro; Franke, Barbara; Hoekstra, Pieter J; Heslenfeld, Dirk J; Oosterlaan, Jaap; Faraone, Stephen V; Buitelaar, Jan K; Hartman, Catharina A

    2016-01-01

    Smaller total brain and subcortical volumes have been linked to psychopathology including attention-deficit/hyperactivity disorder (ADHD). Identifying mechanisms underlying these alterations, therefore, is of great importance. We investigated the role of gene-environment interactions (GxE) in interindividual variability of total gray matter (GM), caudate, and putamen volumes. Brain volumes were derived from structural magnetic resonance imaging scans in participants with (N = 312) and without ADHD (N = 437) from N = 402 families (age M = 17.00, SD = 3.60). GxE effects between DAT1, 5-HTT, and DRD4 and social environments (maternal expressed warmth and criticism; positive and deviant peer affiliation) as well as the possible moderating effect of age were examined using linear mixed modeling. We also tested whether findings depended on ADHD severity. Deviant peer affiliation was associated with lower caudate volume. Participants with low deviant peer affiliations had larger total GM volumes with increasing age. Likewise, developmentally sensitive GxE effects were found on total GM and putamen volume. For total GM, differential age effects were found for DAT1 9-repeat and HTTLPR L/L genotypes, depending on the amount of positive peer affiliation. For putamen volume, DRD4 7-repeat carriers and DAT1 10/10 homozygotes showed opposite age relations depending on positive peer affiliation and maternal criticism, respectively. All results were independent of ADHD severity. The presence of differential age-dependent GxE effects might explain the diverse and sometimes opposing results of environmental and genetic effects on brain volumes observed so far.

  13. Liver regeneration and restoration of liver function after partial hepatectomy in patients with liver tumors

    NARCIS (Netherlands)

    Jansen, P. L.; Chamuleau, R. A.; van Leeuwen, D. J.; Schipper, H. G.; Busemann-Sokole, E.; van der Heyde, M. N.

    1990-01-01

    Liver regeneration and restoration of liver function were studied in six patients who underwent partial hepatectomy with removal of 30-70% of the liver. Liver volume and liver regeneration were studied by single-photon computed tomography (SPECT), using 99mTc-colloid as tracer. The method was

  14. Impact of MLC leaf width on the quality of the dose distribution in partial breast irradiation

    International Nuclear Information System (INIS)

    Height, Felicity J.; Kron, Tomas; Willis, David; Chua, Boon H.

    2012-01-01

    Partial-breast irradiation (PBI) aims to limit the target volume for radiotherapy in women with early breast cancer after partial mastectomy to the region at highest risk of local recurrence, the tumor bed. Multileaf collimators are used to achieve conformal radiation beam portals required for PBI. Narrower leaf widths are generally assumed to allow more conformal shaping of beam portals around irregularly shaped target volumes. The aim was to compare 5-mm and 10-mm leaf widths for patients previously treated using PBI and assess subsequent planning target volume (PTV) coverage and organ at risk (OAR) doses for 16 patients. Several plans (5-mm leaf width or 10-mm leaf width) were generated for each patient using the original treated plan as the basis for attempts at further optimization. Alternating between different leaf widths found no significant difference in terms of overall PTV coverage and OAR doses between treatment plans. Optimization of the original treated plan allowed a small decrease in ipsilateral breast dose, which was offset by a lower PTV minimum. No significant dosimetric difference was found to support an advantage of 5-mm over 10-mm leaf width in this setting.

  15. Late rectal toxicity: dose-volume effects of conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Huang, Eugene H.; Pollack, Alan; Levy, Larry; Starkschall, George; Lei Dong; Rosen, Isaac; Kuban, Deborah A.

    2002-01-01

    Purpose: To identify dosimetric, anatomic, and clinical factors that correlate with late rectal toxicity after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Methods and Materials: We retrospectively analyzed the dose-volume histograms and clinical records of 163 Stage T1b-T3c prostate cancer patients treated between 1992 and 1999 with 3D-CRT, to a total isocenter dose of 74-78 Gy at The University of Texas M. D. Anderson Cancer Center. The median follow-up was 62 months (range 24-102). All late rectal complications were scored using modified Radiation Therapy Oncology Group and Late Effects Normal Tissue Task Force criteria. The 6-year toxicity rate was assessed using Kaplan-Meier analysis and the log-rank test. A univariate proportional hazards regression model was used to test the correlation between Grade 2 or higher toxicity and the dosimetric, anatomic, and clinical factors. In a multivariate regression model, clinical factors were added to the dosimetric and anatomic variables to determine whether they significantly altered the risk of developing late toxicity. Results: At 6 years, the rate of developing Grade 2 or higher late rectal toxicity was 25%. A significant volume effect was observed at rectal doses of 60, 70, 75.6, and 78 Gy, and the risk of developing rectal complications increased exponentially as greater volumes were irradiated. Although the percentage of rectal volume treated correlated significantly with the incidence of rectal complications at all dose levels (p 3 of the rectum. Of the clinical variables tested, only a history of hemorrhoids correlated with rectal toxicity (p=0.003). Multivariate analysis showed that the addition of hemorrhoids increased the risk of toxicity for each dosimetric variable found to be significant on univariate analysis (p<0.05 for all comparisons). Conclusion: Dose-volume histogram analyses clearly indicated a volume effect on the probability of developing late rectal complications

  16. Decreasing Irradiated Rat Lung Volume Changes Dose-Limiting Toxicity From Early to Late Effects

    Energy Technology Data Exchange (ETDEWEB)

    Veen, Sonja J. van der; Faber, Hette; Ghobadi, Ghazaleh [Department of Cell Biology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Brandenburg, Sytze [KVI Center for Advanced Radiation Research, University of Groningen, Groningen (Netherlands); Langendijk, Johannes A. [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Coppes, Robert P. [Department of Cell Biology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Luijk, Peter van, E-mail: p.van.luijk@umcg.nl [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands)

    2016-01-01

    Purpose: Technological developments in radiation therapy result in smaller irradiated volumes of normal tissue. Because the risk of radiation therapy-induced toxicity generally depends on irradiated volume, changing volume could change the dose-limiting toxicity of a treatment. Recently, in our rat model, we found that early radiation-induced lung dysfunction (RILD) was closely related to irradiated volume dependent vascular remodeling besides inflammation. The exact relationship between early and late RILD is still unknown. Therefore, in this preclinical study we investigated the dose-volume relationship of late RILD, assessed its dependence on early and late pathologies and studied if decreasing irradiated volume changed the dose-limiting toxicity. Methods and Materials: A volume of 25%, 32%, 50%, 63%, 88%, or 100% of the rat lung was irradiated using protons. Until 26 weeks after irradiation, respiratory rates were measured. Macrovascular remodeling, pulmonary inflammation, and fibrosis were assessed at 26 weeks after irradiation. For all endpoints dose-volume response curves were made. These results were compared to our previously published early lung effects. Results: Early vascular remodeling and inflammation correlated significantly with early RILD. Late RILD correlated with inflammation and fibrosis, but not with vascular remodeling. In contrast to the early effects, late vascular remodeling, inflammation and fibrosis showed a primarily dose but not volume dependence. Comparison of respiratory rate increases early and late after irradiation for the different dose-distributions indicated that with decreasing irradiated volumes, the dose-limiting toxicity changed from early to late RILD. Conclusions: In our rat model, different pathologies underlie early and late RILD with different dose-volume dependencies. Consequently, the dose-limiting toxicity changed from early to late dysfunction when the irradiated volume was reduced. In patients, early and late

  17. Mathematical Modelling of Intraretinal Oxygen Partial Pressure ...

    African Journals Online (AJOL)

    Purpose: The aim of our present work is to develop a simple steady state model for intraretinal oxygen partial pressure distribution and to investigate the effect of various model parameters on the partial pressure distribution under adapted conditions of light and darkness.. Method: A simple eight-layered mathematical model ...

  18. arXiv Minimal Fundamental Partial Compositeness

    CERN Document Server

    Cacciapaglia, Giacomo; Sannino, Francesco; Thomsen, Anders Eller

    Building upon the fundamental partial compositeness framework we provide consistent and complete composite extensions of the standard model. These are used to determine the effective operators emerging at the electroweak scale in terms of the standard model fields upon consistently integrating out the heavy composite dynamics. We exhibit the first effective field theories matching these complete composite theories of flavour and analyse their physical consequences for the third generation quarks. Relations with other approaches, ranging from effective analyses for partial compositeness to extra dimensions as well as purely fermionic extensions, are briefly discussed. Our methodology is applicable to any composite theory of dynamical electroweak symmetry breaking featuring a complete theory of flavour.

  19. Effects of partial slip boundary condition and radiation on the heat and mass transfer of MHD-nanofluid flow

    Science.gov (United States)

    Abd Elazem, Nader Y.; Ebaid, Abdelhalim

    2017-12-01

    In this paper, the effect of partial slip boundary condition on the heat and mass transfer of the Cu-water and Ag-water nanofluids over a stretching sheet in the presence of magnetic field and radiation. Such partial slip boundary condition has attracted much attention due to its wide applications in industry and chemical engineering. The flow is basically governing by a system of partial differential equations which are reduced to a system of ordinary differential equations. This system has been exactly solved, where exact analytical expression has been obtained for the fluid velocity in terms of exponential function, while the temperature distribution, and the nanoparticles concentration are expressed in terms of the generalized incomplete gamma function. In addition, explicit formulae are also derived from the rates of heat transfer and mass transfer. The effects of the permanent parameters on the skin friction, heat transfer coefficient, rate of mass transfer, velocity, the temperature profile, and concentration profile have been discussed through tables and graphs.

  20. Effects of alkylresorcinols on volume and structure of yeast-leavened bread.

    Science.gov (United States)

    Andersson, Annica Am; Landberg, Rikard; Söderman, Thomas; Hedkvist, Sofie; Katina, Kati; Juvonen, Riikka; Holopainen, Ulla; Lehtinen, Pekka; Aman, Per

    2011-01-30

    Alkylresorcinols (AR) are amphiphilic phenolic compounds found in high amounts in wheat, durum wheat and rye, with different homologue composition for each cereal. The effect of different amounts of added AR from these cereals on bread volume, height, porosity and microstructure was studied. Breads with added rye bran (with high levels of AR) or acetone-extracted rye bran (with low levels of AR) were also baked, as well as breads with finely milled forms of each of these brans. Breads with high amounts of added AR, irrespective of AR homologue composition, had a lower volume, a more compact structure and an adverse microstructure compared with breads with no or low levels of added AR. AR were also shown to inhibit the activity of baker's yeast. There was no difference in bread volume and porosity between bread baked with rye bran and acetone-extracted rye bran or with brans of different particle size. Irrespective of homologue composition, AR had a negative effect on wheat bread properties when added in high amounts as purified extracts from wheat, durum wheat and rye. Natural levels of AR in rye bran, however, did not affect the volume and porosity of yeast-leavened wheat breads. 2010 Society of Chemical Industry.

  1. Quark-nuclear hybrid star equation of state with excluded volume effects

    Science.gov (United States)

    Kaltenborn, Mark Alexander Randolph; Bastian, Niels-Uwe Friedrich; Blaschke, David Bernhard

    2017-09-01

    A two-phase description of the quark-nuclear matter hybrid equation of state that takes into account the effect of excluded volume in both the hadronic and the quark-matter phases is introduced. The nuclear phase manifests a reduction of the available volume as density increases, leading to a stiffening of the matter. The quark-matter phase displays a reduction of the effective string tension in the confining density functional from available volume contributions. The nuclear equation of state is based upon the relativistic density-functional model DD2 with excluded volume. The quark-matter equation of state is based upon a quasiparticle model derived from a relativistic density-functional approach and will be discussed in greater detail. The interactions are decomposed into mean scalar and vector components. The scalar interaction is motivated by a string potential between quarks, whereas the vector interaction potential is motivated by higher-order interactions of quarks leading to an increased stiffening at high densities. As an application, we consider matter under compact star constraints of electric neutrality and β equilibrium. We obtain mass-radius relations for hybrid stars that form a third family, disconnected from the purely hadronic star branch, and fulfill the 2 M⊙ constraint.

  2. Is Annual Volume Enough? The Role of Experience and Specialization on Inpatient Mortality After Hepatectomy.

    Science.gov (United States)

    Hashimoto, Daniel A; Bababekov, Yanik J; Mehtsun, Winta T; Stapleton, Sahael M; Warshaw, Andrew L; Lillemoe, Keith D; Chang, David C; Vagefi, Parsia A

    2017-10-01

    To investigate the effect of subspecialty practice and experience on the relationship between annual volume and inpatient mortality after hepatic resection. The impact of annual surgical volume on postoperative outcomes has been extensively examined. However, the impact of cumulative surgeon experience and specialty training on this relationship warrants investigation. The New York Statewide Planning and Research Cooperative System inpatient database was queried for patients' ≥18 years who underwent wedge hepatectomy or lobectomy from 2000 to 2014. Primary exposures included annual surgeon volume, surgeon experience (early vs late career), and surgical specialization-categorized as general surgery (GS), surgical oncology (SO), and transplant (TS). Primary endpoint was inpatient mortality. Hierarchical logistic regression was performed accounting for correlation at the level of the surgeon and the hospital, and adjusting for patient demographics, comorbidities, presence of cirrhosis, and annual surgical hospital volume. A total of 13,467 cases were analyzed. Overall inpatient mortality was 2.35%. On unadjusted analysis, late career surgeons had a mortality rate of 2.62% versus 1.97% for early career surgeons. GS had a mortality rate of 2.98% compared with 1.68% for SO and 2.67% for TS. Once risk-adjusted, annual volume was associated with reduced mortality only among early-career surgeons (odds ratio 0.82, P = 0.001) and general surgeons (odds ratio 0.65, P = 0.002). No volume effect was seen among late-career or specialty-trained surgeons. Annual volume alone likely contributes only a partial assessment of the volume-outcome relationship. In patients undergoing hepatic resection, increased annual volume did not confer a mortality benefit on subspecialty surgeons or late career surgeons.

  3. Recurrent Partial Words

    Directory of Open Access Journals (Sweden)

    Francine Blanchet-Sadri

    2011-08-01

    Full Text Available Partial words are sequences over a finite alphabet that may contain wildcard symbols, called holes, which match or are compatible with all letters; partial words without holes are said to be full words (or simply words. Given an infinite partial word w, the number of distinct full words over the alphabet that are compatible with factors of w of length n, called subwords of w, refers to a measure of complexity of infinite partial words so-called subword complexity. This measure is of particular interest because we can construct partial words with subword complexities not achievable by full words. In this paper, we consider the notion of recurrence over infinite partial words, that is, we study whether all of the finite subwords of a given infinite partial word appear infinitely often, and we establish connections between subword complexity and recurrence in this more general framework.

  4. Principles and techniques of radiation hardening. Volume 2. Transient radiation effects in electronics (TREE)

    International Nuclear Information System (INIS)

    Rudie, N.J.

    1976-01-01

    The three-volume book is intended to serve as a review of the effects of thermonuclear explosion induced radiation (x-rays, gamma rays, and beta particles) and the resulting electromagnetic pulse (EMP). Volume 2 deals with the following topics: radiation effects on quartz crystals, tantalum capacitors, bipolar semiconductor devices and integrated circuits, field effect transistors, and miscellaneous electronic devices; hardening electronic systems to photon and neutron radiation; nuclear radiation source and/or effects simulation techniques; and radiation dosimetry

  5. Constrained Optimization and Optimal Control for Partial Differential Equations

    CERN Document Server

    Leugering, Günter; Griewank, Andreas

    2012-01-01

    This special volume focuses on optimization and control of processes governed by partial differential equations. The contributors are mostly participants of the DFG-priority program 1253: Optimization with PDE-constraints which is active since 2006. The book is organized in sections which cover almost the entire spectrum of modern research in this emerging field. Indeed, even though the field of optimal control and optimization for PDE-constrained problems has undergone a dramatic increase of interest during the last four decades, a full theory for nonlinear problems is still lacking. The cont

  6. Groundwater flow modelling of an abandoned partially open repository

    Energy Technology Data Exchange (ETDEWEB)

    Bockgaard, Niclas (Golder Associates AB (Sweden))

    2010-12-15

    As a part of the license application, according to the nuclear activities act, for a final repository for spent nuclear fuel at Forsmark, the Swedish Nuclear Fuel and Waste Management Company (SKB) has undertaken a series of groundwater flow modelling studies. These represent time periods with different hydraulic conditions and the simulations carried out contribute to the overall evaluation of the repository design and long-term radiological safety. The modelling study presented here serves as an input for analyses of so-called future human actions that may affect the repository. The objective of the work was to investigate the hydraulic influence of an abandoned partially open repository. The intention was to illustrate a pessimistic scenario of the effect of open tunnels in comparison to the reference closure of the repository. The effects of open tunnels were studied for two situations with different boundary conditions: A 'temperate' case with present-day boundary conditions and a generic future 'glacial' case with an ice sheet covering the repository. The results were summarized in the form of analyses of flow in and out from open tunnels, the effect on hydraulic head and flow in the surrounding rock volume, and transport performance measures of flow paths from the repository to surface

  7. Groundwater flow modelling of an abandoned partially open repository

    International Nuclear Information System (INIS)

    Bockgaard, Niclas

    2010-12-01

    As a part of the license application, according to the nuclear activities act, for a final repository for spent nuclear fuel at Forsmark, the Swedish Nuclear Fuel and Waste Management Company (SKB) has undertaken a series of groundwater flow modelling studies. These represent time periods with different hydraulic conditions and the simulations carried out contribute to the overall evaluation of the repository design and long-term radiological safety. The modelling study presented here serves as an input for analyses of so-called future human actions that may affect the repository. The objective of the work was to investigate the hydraulic influence of an abandoned partially open repository. The intention was to illustrate a pessimistic scenario of the effect of open tunnels in comparison to the reference closure of the repository. The effects of open tunnels were studied for two situations with different boundary conditions: A 'temperate' case with present-day boundary conditions and a generic future 'glacial' case with an ice sheet covering the repository. The results were summarized in the form of analyses of flow in and out from open tunnels, the effect on hydraulic head and flow in the surrounding rock volume, and transport performance measures of flow paths from the repository to surface

  8. A newly developed snack effective for enhancing bone volume

    Directory of Open Access Journals (Sweden)

    Hayashi Hidetaka

    2009-07-01

    Full Text Available Abstract Background The incidence of primary osteoporosis is higher in Japan than in USA and European countries. Recently, the importance of preventive medicine has been gradually recognized in the field of orthopaedic surgery with a concept that peak bone mass should be increased in childhood as much as possible for the prevention of osteoporosis. Under such background, we have developed a new bean snack with an aim to improve bone volume loss. In this study, we examined the effects of a newly developed snack on bone volume and density in osteoporosis model mice. Methods Orchiectomy (ORX and ovariectomy (OVX were performed for C57BL/6J mice of twelve-week-old (Jackson Laboratory, Bar Harbar, ME, USA were used in this experiment. We prepared and given three types of powder diet e.g.: normal calcium diet (NCD, Ca: 0.9%, Clea Japan Co., Tokyo, Japan, low calcium diet (LCD, Ca: 0.63%, Clea Japan Co., and special diet (SCD, Ca: 0.9%. Eighteen weeks after surgery, all the animals were sacrified and prepared for histomorphometric analysis to quantify bone density and bone mineral content. Results As a result of histomorphometric examination, SCD was revealed to enhance bone volume irrespective of age and sex. The bone density was increased significantly in osteoporosis model mice fed the newly developmental snack as compared with the control mice. The bone mineral content was also enhanced significantly. These phenomena were revealed in both sexes. Conclusion It is shown that the newly developed bean snack is highly effective for the improvement of bone volume loss irrespective of sex. We demonstrated that newly developmental snack supplements may be a useful preventive measure for Japanese whose bone mineral density values are less than the ideal condition.

  9. Effectiveness of Nissen fundoplication versus anterior and posterior partial fundoplications for treatment of gastro-esophageal reflux disease: a systematic review protocol.

    Science.gov (United States)

    Marshall-Webb, Matthew; Peters, Micah D J; Bright, Tim; Watson, David I

    2018-05-01

    The objective of this review is to determine the relative effectiveness of Nissen fundoplication compared to anterior and posterior partial fundoplication in controlling the symptoms of gastro-esophageal reflux disease and reducing their side effect profile in adults.The specific questions posed by this review are: what is the effectiveness of Nissen fundoplication in comparison to anterior partial fundoplication (90 degree, 120 degree and 180 degree) and posterior 270 degree fundoplication in terms of symptom control of gastro-esophageal reflux disease, and what are the side effects of these surgical interventions?

  10. Cost-effectiveness of silver dressings for paediatric partial thickness burns: An economic evaluation from a randomized controlled trial.

    Science.gov (United States)

    Gee Kee, E; Stockton, K; Kimble, R M; Cuttle, L; McPhail, S M

    2017-06-01

    Partial thickness burns of up to 10% total body surface area (TBSA) in children are common injuries primarily treated in the outpatient setting using expensive silver-containing dressings. However, economic evaluations in the paediatric burns population are lacking to assist healthcare providers when choosing which dressing to use. The aim of this study was to conduct a cost-effectiveness analysis of three silver dressings for partial thickness burns ≤10% TBSA in children aged 0-15 years using days to full wound re-epithelialization as the health outcome. This study was a trial based economic evaluation (incremental cost effectiveness) conducted from a healthcare provider perspective. Ninety-six children participated in the trial investigating Acticoat™, Acticoat™ with Mepitel™ or Mepilex Ag™. Costs directly related to the management of partial thickness burns ≤10% TBSA were collected during the trial from March 2013 to July 2014 and for a one year after re-epithelialization time horizon. Incremental cost effectiveness ratios were estimated and dominance probabilities calculated from bootstrap resampling trial data. Sensitivity analyses were conducted to examine the potential effect of accounting for infrequent, but high cost, skin grafting surgical procedures. Costs (dressing, labour, analgesics, scar management) were considerably lower in the Mepilex Ag™ group (median AUD$94.45) compared to the Acticoat™ (median $244.90) and Acticoat™ with Mepitel™ (median $196.66) interventions. There was a 99% and 97% probability that Mepilex Ag™ dominated (cheaper and more effective than) Acticoat™ and Acticoat™ with Mepitel™, respectively. This pattern of dominance was consistent across raw cost and effects, after a priori adjustments, and sensitivity analyses. There was an 82% probability that Acticoat™ with Mepitel dominated Acticoat™ in the primary analysis, although this probability was sensitive to the effect of skin graft procedures. This

  11. Effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit.

    Science.gov (United States)

    Xi, Peng; Li, Yan; Ge, Xiaojin; Liu, Dandan; Miao, Mingsan

    2018-05-01

    Observing the effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit. We prepared boiling water scalded rabbits with deep II degree scald models and applied high, medium and low doses of nano-silver hydrogel coating film for different time and area. Then we compared the difference of burned paper weight before administration and after administration model burns, burn local skin irritation points infection, skin crusting and scabs from the time, and the impact of local skin tissue morphology. Rabbits deep II degree burn model successful modeling; on day 12, 18, high, medium and low doses of nano-silver hydrogel coating film significantly reduced skin irritation of rabbits infected with the integral value ( P  film group significantly decreased skin irritation, infection integral value ( P  film significantly reduced film rabbits' scalded skin crusting time ( P  film on the deep partial thickness burns has a significant therapeutic effect; external use has a significant role in wound healing.

  12. Effectiveness comparison of partially executed t-way test suite based generated by existing strategies

    Science.gov (United States)

    Othman, Rozmie R.; Ahmad, Mohd Zamri Zahir; Ali, Mohd Shaiful Aziz Rashid; Zakaria, Hasneeza Liza; Rahman, Md. Mostafijur

    2015-05-01

    Consuming 40 to 50 percent of software development cost, software testing is one of the most resource consuming activities in software development lifecycle. To ensure an acceptable level of quality and reliability of a typical software product, it is desirable to test every possible combination of input data under various configurations. Due to combinatorial explosion problem, considering all exhaustive testing is practically impossible. Resource constraints, costing factors as well as strict time-to-market deadlines are amongst the main factors that inhibit such consideration. Earlier work suggests that sampling strategy (i.e. based on t-way parameter interaction or called as t-way testing) can be effective to reduce number of test cases without effecting the fault detection capability. However, for a very large system, even t-way strategy will produce a large test suite that need to be executed. In the end, only part of the planned test suite can be executed in order to meet the aforementioned constraints. Here, there is a need for test engineers to measure the effectiveness of partially executed test suite in order for them to assess the risk they have to take. Motivated by the abovementioned problem, this paper presents the effectiveness comparison of partially executed t-way test suite generated by existing strategies using tuples coverage method. Here, test engineers can predict the effectiveness of the testing process if only part of the original test cases is executed.

  13. Aperiodic Volume Optics

    Science.gov (United States)

    Gerke, Tim D.

    Presented in this thesis is an investigation into aperiodic volume optical devices. The three main topics of research and discussion are the aperiodic volume optical devices that we call computer-generated volume holograms (CGVH), defects within periodic 3D photonic crystals, and non-periodic, but ordered 3D quasicrystals. The first of these devices, CGVHs, are designed and investigated numerically and experimentally. We study the performance of multi-layered amplitude computer-generated volume holograms in terms of efficiency and angular/frequency selectivity. Simulation results show that such aperiodic devices can increase diffraction efficiency relative to periodic amplitude volume holograms while maintaining angular and wavelength selectivity. CGVHs are also designed as voxelated volumes using a new projection optimization algorithm. They are investigated using a volumetric diffraction simulation and a standard 3D beam propagation technique as well as experimentally. Both simulation and experiment verify that the structures function according to their design. These represent the first diffractive structures that have the capacity for generating arbitrary transmission and reflection wave fronts and that provide the ability for multiplexing arbitrary functionality given different illumination conditions. Also investigated and discussed in this thesis are 3D photonic crystals and quasicrystals. We demonstrate that these devices can be fabricated using a femtosecond laser direct writing system that is particularly appropriate for fabrication of such arbitrary 3D structures. We also show that these devices can provide 3D partial bandgaps which could become complete bandgaps if fabricated using high index materials or by coating lower index materials with high index metals. Our fabrication method is particularly suited to the fabrication of engineered defects within the periodic or quasi-periodic systems. We demonstrate the potential for fabricating defects within

  14. Bronchial effects of leukotriene D4 inhalation in normal human lung

    DEFF Research Database (Denmark)

    Bisgaard, H; Groth, S

    1987-01-01

    airways in asthmatic patients out of attack. LTD4 caused a dose-dependent obstruction of the airways as measured by partial flow-volume curves and volume of trapped gas, yet only minor changes in forced expiratory volume in 1 s (FEV1) and peak expiratory flow rate. LTD4 was 1900-7000 times more potent......The aim of the study was to investigate whether inhaled leukotriene (LT) D4 could mimic the characteristics of asthmatic patients after allergen-induced attack, i.e. a prolonged subclinical bronchial obstruction, an increased reactivity of the airways and a late reaction. The effects of LTD4 were...... than histamine. LTD4 inhalations were almost symptomless as opposed to the irritative and dyspnoeic symptoms seen after inhalation of histamine. The time duration for the induced change in partial flow-volume curves was the same for the two drugs. Approximately 30 min elapsed until the bronchial...

  15. World-volume effective theory for higher-dimensional black holes.

    Science.gov (United States)

    Emparan, Roberto; Harmark, Troels; Niarchos, Vasilis; Obers, Niels A

    2009-05-15

    We argue that the main feature behind novel properties of higher-dimensional black holes, compared to four-dimensional ones, is that their horizons can have two characteristic lengths of very different size. We develop a long-distance world-volume effective theory that captures the black hole dynamics at scales much larger than the short scale. In this limit the black hole is regarded as a blackfold: a black brane (possibly boosted locally) whose world volume spans a curved submanifold of the spacetime. This approach reveals black objects with novel horizon geometries and topologies more complex than the black ring, but more generally it provides a new organizing framework for the dynamics of higher-dimensional black holes.

  16. Effects of horizontal plyometric training volume on soccer players' performance.

    Science.gov (United States)

    Yanci, Javier; Los Arcos, Asier; Camara, Jesús; Castillo, Daniel; García, Alberto; Castagna, Carlo

    2016-01-01

    The aim of this study was to examine the dose response effect of strength and conditioning programmes, involving horizontally oriented plyometric exercises, on relevant soccer performance variables. Sixteen soccer players were randomly allocated to two 6-week plyometric training groups (G1 and G2) differing by imposed (twice a week) training volume. Post-training G1 (4.13%; d = 0.43) and G2 (2.45%; d = 0.53) moderately improved their horizontal countermovement jump performance. Significant between-group differences (p  0.05, d = trivial or small) post-training improvements in sprint, change of direction ability (CODA) and horizontal arm swing countermovement jump were reported in either group. Horizontal plyometric training was effective in promoting improvement in injury prevention variables. Doubling the volume of a horizontal plyometric training protocol was shown to have no additional effect over functional aspects of soccer players' performance.

  17. Effect of reinforcement volume fraction on the density & elastic ...

    African Journals Online (AJOL)

    Effect of reinforcement volume fraction on the density & elastic parameters of BMG's matrix composites. Wahiba Metiri 1, Fatiha Hadjoub1, 2 and Leila Touati Tliba 1. 1 Laboratoire des Semi-Conducteurs, Département de Physique, Faculté des Sciences, Université Badji-. Mokhtar, BP 12, Annaba -23000, Algeria.

  18. Market forces can help lower waste volumes

    International Nuclear Information System (INIS)

    Stavins, R.N.

    1993-01-01

    Market forces can go a long way toward helping communities solve their mounting solid-waste problems. In most communities the increasing costs of solid-waste disposal are invisible to the average homeowner because they are buried in local property tax rates. Even in the few communities that list disposal costs separately on tax bills, individual costs are not related to the volume of waste generated. Fundamental to an effective waste-management strategy is the removal of these distortions by getting the prices right. But even with improved price signals, there is no silver bullet of public policy for solid- and hazardous-waste management. Until the ubiquitous NIMBY (Not In My Backyard) problem is addressed, even the most innovative set of waste management policies will remain, at best, a partial solution

  19. Effectiveness, safety, and cost of partial exchange transfusions in patients with sickle-cell anemia at a sickle cell disease center in sub-Saharan Africa.

    Science.gov (United States)

    Boma Muteb, P; Kaluila Mamba, J F J; Muhau Pfutila, P; Bilo, V; Panda Mulefu, J D; Diallo, D A

    2017-11-01

    The partial exchange transfusions necessary for management of some sickle-cell complications raise the issue of effectiveness in the context of limited resources and inadequate blood safety. This study evaluated the effectiveness, safety, and cost of partial exchange transfusions in 39 patients with sickle-cell anemia in Lubumbashi, looking at the patients' age and gender and the tolerability and direct cost of the transfusions. Excel and SPSS 18 were used for data entry and analysis. Chi2 and Fisher exact tests were used for comparisons. A P-value ≤ 5% was considered statistically significant. The average age of patients was 8.6 ± 6.4 years, and the majority were girls. The most frequent indications were stroke, severe infections, severe vasooclusive crises, and acute chest syndrome. Partial exchange transfusions were effective in improving hemoglobin and hematocrit as well as the percentage of HbS. No acute accident was observed during any partial exchange transfusion; one anti-Kell alloimmunization and 2 cases of iron overload were observed. The annual cost of partial exchange transfusions per patient requiring (and able to afford) regular treatment was US $ 3,345 without iron chelation and more than US $ 5000 with chelation. Partial exchange transfusions are effective and tolerated, but financially inaccessible to the majority of our sickle cell patients. Thus, an assessment is needed of the economic burden of sickle cell complications that require partial exchange transfusions in the context of countries with limited financial resources.

  20. The effect of γ radiation on a change in the volume of Protozoa cells

    International Nuclear Information System (INIS)

    Kalinowska, A.

    1977-01-01

    An investigation was carried out on the effect of various doses of γ radiation on changes in the volume of Spirostomum ambiguum and on the time of return of the volume of this protozoan to the initial state. It was found that γ rays brought about a decrease in the volume of the animal, depending in a linear relation on the dose, while the return of the volume to the initial state is negatively correlated with the received dose. (author)