WorldWideScience

Sample records for partial thromboplastin time

  1. 21 CFR 864.7925 - Partial thromboplastin time tests.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Partial thromboplastin time tests. 864.7925 Section 864.7925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7925 Partial...

  2. Unbelievable but true: Partial thromboplastin time, kaolin 120 s and yet no surgical bleed!

    Directory of Open Access Journals (Sweden)

    Shagun Bhatia Shah

    2017-01-01

    Full Text Available Partial thromboplastin time, kaolin (PTTK is a global test sensitive to low levels of all the coagulation factors, except Factor VII and Factor XIII. Patients with extensive cancer have a propensity to develop a shortened PTTK. Our breast cancer patient had a prolonged PTTK result roughly 4 times the normal values. A detailed description of the preoperative workup including the special investigations is required to ascertain the cause of the prolongation and precautions taken, leading to successful breast cancer surgery and postoperative period in this patient follows. Allowing the surgeon to operate a patient with a PTTK >120 s and simultaneously at risk of thrombosis due to lupus anticoagulant is possible with a calculated risk and thorough preoperative evaluation. Prophylactic fresh frozen plasma and deep venous thrombosis prophylaxis have an important role.

  3. Association between Activated Partial Thromboplastin Time and the Amount of Infused Heparin at Bone Marrow Transplantation.

    Science.gov (United States)

    Kusuda, Machiko; Kimura, Shun-Ichi; Misaki, Yukiko; Yoshimura, Kazuki; Gomyo, Ayumi; Hayakawa, Jin; Tamaki, Masaharu; Akahoshi, Yu; Ugai, Tomotaka; Kameda, Kazuaki; Wada, Hidenori; Ishihara, Yuko; Kawamura, Koji; Sakamoto, Kana; Sato, Miki; Terasako-Saito, Kiriko; Kikuchi, Misato; Nakasone, Hideki; Kako, Shinichi; Tanihara, Aki; Kanda, Yoshinobu

    2018-03-27

    The actual heparin concentration of harvested allogeneic bone marrow varies among harvest centers. We monitor the activated partial thromboplastin time (APTT) of the patient during bone marrow infusion and administer prophylactic protamine according to the APTT. We retrospectively reviewed the charts of consecutive patients who underwent bone marrow transplantation without bone marrow processing at our center between April 2007 and March 2016 (n = 94). APTT was monitored during marrow transfusion in 52 patients. We analyzed the relationship between the APTT ratio and several parameters related to heparin administration. As a result, the weight-based heparin administration rate (U/kg/hour) seemed to be more closely related to the APTT ratio (r = .38, P = .005) than to the total amount of heparin. There was no significant correlation between the APTT ratio and renal or liver function. Bleeding complications during and early after infusion were seen in 3 of 52 patients, and included intracranial, nasal, and punctured-skin bleeding. The APTT ratio during transfusion was over 5.88 in the former 2 patients and 2.14 in the latter. All of these patients recovered without sequelae. In conclusion, slow bone marrow infusion is recommended to decrease the weight-based heparin administration rate when the heparin concentration per patient body weight is high. Copyright © 2018 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  4. The influence of N-acetylcysteine on the measurement of prothrombin time and activated partial thromboplastin time in healthy subjects

    DEFF Research Database (Denmark)

    Jepsen, S; Hansen, A B

    1994-01-01

    mg kg-1 h-1 for 32 h in six male subjects. The intrinsic, extrinsic and common pathway of coagulation were monitored with activated partial thromboplastin time (APTT), and prothrombin time, respectively. In addition, the extrinsic coagulation pathway was monitored with the clotting activity of single...... factors II, VII, and X. No effect on the intrinsic coagulation pathway was observed. There was a significant and rapid decrease in prothrombin time. Coagulation factors II, VII and X, the three components of prothrombin time, decreased significantly to different degrees. We conclude that infusion of N...

  5. Prothrombin Time, Activated Partial Thromboplastin Time, Fibrinogen, dan D-dimer Sebagai Prediktor Decompensated Disseminated Intravascular Coagulation Sisseminated pada Sepsis

    Directory of Open Access Journals (Sweden)

    Fenny

    2011-03-01

    Full Text Available Sepsis is a systemic response to infection especially in pneumonia case. Sepsis can cause complications such as disseminated intravascular coagulation (DIC which can be divided into compensated and decompensated DIC. The purpose of this study was to assess whether the value of prothrombin time (PT, activated partial thromboplastin time (aPTT, fibrinogen, and D-dimer levels can be used as predictors of decompensated DIC in sepsis patients. This study was conducted at the Laboratory of Clinical Pathology Rumah Sakit Hasan Sadikin Bandung since September 2008 to June 2010. Subjects were patients with sepsis caused by pneumonia. PT and aPTT values, fibrinogen, and D-dimer levels was recorded from all sepsis patients then patients were observed until diagnosed decompensated or non-decompensated DIC, then the value of PT, aPTT, fibrinogen and D-dimer levels in the group of decompensated DIC and non-decompensated DIC were analysed. This study used cohort design. Subjects were 39 sepsis patients (58% with outcome decompensated DIC and 28 sepsis patients (42% with outcome non-decompensated DIC. From the hemostasis parameter test out, it was found that PT, aPTT, and fibrinogen were the predictor of decompensated DIC in patients with sepsis with relative risk 240.500, 7.157, and 6.421; respectively. Conclusions, prothrombin time, aPTT, fibrinogen are the test to know coagulation activation. Hemostasis parameter to predict decompensated DIC in sepsis patients are the shorten PT, aPTT, and the increased fibrinogen

  6. Anticoagulant effects of inhaled unfractionated heparin in the dog as determined by partial thromboplastin time and factor Xa activity.

    Science.gov (United States)

    Manion, Jill S; Thomason, John M; Langston, Vernon C; Claude, Andrew K; Brooks, Marjory B; Mackin, Andrew J; Lunsford, Kari V

    2016-01-01

    To evaluate the anticoagulant effects of inhaled heparin in dogs. This study was conducted in 3 phases. In phase 1, bronchoalveolar lavage fluid (BALf) was collected to generate an in vitro calibration curve to relate heparin concentration to the activated partial thromboplastin time (aPTT). In phase 2, heparin was administered via nebulization to determine the threshold dose needed to prolong systemic aPTT. In phase 3, the local anticoagulant activity of inhaled heparin was determined by measurement of BALf anti-Xa activity and aPTT. University teaching hospital. Six healthy intact female Walker Hounds were used in this study. Two dogs were used for each phase. Inhaled unfractionated sodium heparin was administered in doses ranging from 50,000 to 200,000 IU. In vitro addition of heparin to BALf caused a prolongation in aPTT. Inhaled heparin at doses as high as 200,000 IU failed to prolong systemic aPTT, and a threshold dose could not be determined. No significant local anticoagulant effects were detected. Even at doses higher than those known to be effective in people, inhaled heparin appears to have no detectable local or systemic anticoagulant effects in dogs with the current delivery method. © Veterinary Emergency and Critical Care Society 2015.

  7. Indium-111-labeled platelets: effect of heparin on uptake by venous thrombi and relationship to the activated partial thromboplastin time

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Moser, K.M.; Moser, K.S.; Konopka, R.; Hartman, M.T.

    1982-01-01

    The goal of heparin thepapy in deep vein thrombosis is to prevent thrombus extension. The relationship between thrombus extension and the results of coagulation tests used to monitor heparin thepapy is unclear. To expose this relationship, we studied the effect of several heparin regimens on the accretion of indium-111-labeled platelets on fresh venous thrombi, as detected by gamma imaging, and monitored the activated partial thromboplastin time (APTT). Six dogs were treated with a 300-U/kg bolus of heparin followed by a 90-U/kg/hour heparin infusion, a dose of heparin sufficient to increase the APTT to levels greater than eight times baseline (APTT ratio); platelet accretion (thrombus imaging) occurred only after the heparin effect was reversed with protamine sulfate. Nineteen dogs were treated with a 150-U/kg bolus of heparin followed by a 4-hour, 45-U/kg/hour heparin infusion; a thrombus was demonstrated only after protamine injection in 12 (mean APTT ratio 1.3 +/- 0.19) and before protamine injection in seven. In thirteen of these 19 dogs, 30 minutes separated the platelet injection from heparin therapy, while in six this duration was less than 30 minutes. In four of these six dogs, thrombi were demonstrated before protamine therapy and at APTT ratios greater than 3.0. Finally, 10 dogs were treated with a 100-U/kg bolus followed by a 3-hour, 50-U/kg/hour heparin infusion, after which the APTT was allowed to return to baseline values spontaneously. In all 10 dogs, a thrombus was demonstrated only after cessation of the heparin infusion, and at a mean APTT ratio of 1.4 +/- 0.15 times baseline. These results suggest that, except with very early platelet injection, platelet accretion by thrombi is consistently inhibited by heparin at APTT ratios greater than 2.5

  8. The analysis of false prolongation of the activated partial thromboplastin time (activator: silica): Interference of C-reactive protein.

    Science.gov (United States)

    Liu, Jie; Li, Fanfan; Shu, Kuangyi; Chen, Tao; Wang, Xiaoou; Xie, Yaoqi; Li, Shanshan; Zhang, Zhaohua; Jin, Susu; Jiang, Minghua

    2018-05-13

    To investigate the effect of C-reactive protein on the activated partial thromboplastin time (APTT) (different activators) in different detecting systems. The C-reactive protein and coagulation test of 112 patients with the infectious disease were determined by automation protein analyzer IMMAG 800 and automation coagulation analyzer STA-R Evolution, respectively. The pooled plasma APTT with different concentrations of C-reactive protein was measured by different detecting system: STA-R Evolution (activator: silica, kaolin), Sysmex CS-2000i (activator: ellagic acid), and ACL TOP 700 (activator: colloidal silica). In addition, the self-made platelet lysate (phospholipid) was added to correct the APTT prolonged by C-reactive protein (150 mg/L) on STA-R Evolution (activator: silica) system. The good correlation between C-reactive protein and APTT was found on the STA-R Evolution (activator: silica) system. The APTT on the STA-R Evolution (activator: silica) system was prolonged by 24.6 second, along with increasing C-reactive protein concentration. And the APTT of plasma containing 150 mg/L C-reactive protein was shortened by 3.4-6.9 second when the plasma was mixed with self-made platelet lysate. However, the APTT was prolonged unobviously on other detecting systems including STA-R Evolution (activator: kaolin), Sysmex CS-2000i, and ACL TOP 700. C-reactive protein interferes with the detection of APTT, especially in STA-R Evolution (activator: silica) system. The increasing in C-reactive protein results in a false prolongation of the APTT (activator: silica), and it is most likely that C-reactive protein interferes the coagulable factor binding of phospholipid. © 2018 Wiley Periodicals, Inc.

  9. Comparing the Effect of Continuous and Intermittent Irrigation Techniques on Complications of Arterial Catheter and Partial Thromboplastin Time in Patients Following Coronary Artery Bypass Grafting Surgery

    Directory of Open Access Journals (Sweden)

    Sedigheh Arta

    2017-04-01

    Full Text Available Background: Different approaches are available to irrigate the arterial catheter, such as continuous and intermittent techniques. However, there is a disagreement regarding the most appropriate method. Aim: this study aimed to compare the effect of two continuous and intermittent irrigation methods on complications of arterial catheter and partial thromboplastin time (PTT in patients with coronary artery bypass (CABG surgery. Method: This randomized clinical trial was conducted on 60 participants undergoing coronary artery bypass grafting surgery in open-heart surgery ICU at Imam Reza hospital in Mashhad, Iran, in 2016. In continuous group, the arterial catheter was continuously irrigated with heparin solution at the rate of 2cc/h, and in the intermittent group with a syringe containing 5cc heparin solution every 3 hours. In both groups, catheter was monitored and recorded every 3 hours (until 48 hours and 3 times from enrollment in terms of complications of partial thromboplastin time. Data were analyzed using SPSS version 16. Results: The findingsof independent t-test showed that the two groups are homogeneous in age (P =0.48. The result of Fisher's exact test revealed no significant difference between the two groups in terms of average incidence of complications during the first 24 hours (P=0.55 and second 24 hours (P=0.55 after catheterization. Also during the 48 hours after surgery, independent t-test results showed no statistically significant difference in partial thromboplastin time (P=0.53 between the two groups. Implications for Practice: According to the results of the research based on the lack of difference between continuous and intermittent irrigation methods up to 48 hours after catheter replacement in terms of arterial catheter complications, further long-term follow-up researches are recommended.

  10. EFFECT OF METHANOLIC SEED EXTRACT OF PERSEA AMERICANA(AVOCADO PEAR ON PROTHROMBIN TIME AND ACTIVATED PARTIAL THROMBOPLASTIN TIME IN MICE

    Directory of Open Access Journals (Sweden)

    2016-11-01

    Full Text Available Twenty (20 adult albino mice were used in the study to determine the effect of methanolic seed extract of Persea Americana on prothrombin time (PT and activated partial thromboplastin time (APTT test. The mice were obtained and kept for 2 weeks to acclimatize. They were weighed and divided into 5 groups. Group A served as control without the extract. Groups B to E were orally administered with graded doses of 200mg, 400 mg, 800 mg and 1600mg/kg body weight per mice daily for 28 days. Blood samples were collected through the median canthus into ti-sodium citrate anticoagulant containers for the analysis of PT and APTT, using standard operative procedure. The analysis was carried out at the Haematology Laboratory of University of Nigeria Teaching Hospital (UNTH Enugu. The results showed a prolonged APTT time at all the doses of the extract when compared with the control (P and lt;0.05. The prothrombin time at the dosage of 200mg/kg did not differ when compared with the control (P and gt;0.05. The increase in PT and APTT was dose dependent. This result pattern suggests that the extract causes prolonged prothrombin time and APTT at various concentrations possibly due to its high potassium content. The extract can be recommended in anticoagulant therapy since it prolongs PT and APTT.

  11. 111In-labeled platelets: effects of heparin on uptake by venous thrombi and relationship to the activated partial thromboplastin time

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Moser, K.M.; Moser, K.S.; Konopka, R.; Hartman, M.T.

    1982-01-01

    The goal of heparin therapy in deep vein thrombosis is to prevent thrombus extension. The relationship between thrombus extension and the results of coagulation tests used to monitor heparin therapy is unclear. To explore this relationship, we studied the effect of several heparin regimens on the accretion of 111 In-labeled platelets on fresh venous thrombi, as detected by gamma imaging, and monitored the activated partial thromboplastin time (APTT). Six dogs were treated with a 300-U/kg bolus of heparin followed by a 90-U/kg/hour heparin infusion, a dose of heparin sufficient to increase the APTT to levels greater than eight times baseline (APTT ratio); platelet accretion (thrombus imaging) occurred only after the heparin effect was reversed with protamine sulfate. Nineteen dogs were treated with a 150-U/kg bolus of heparin followed by a 4-hour, 45-U/kg/hour heparin infusion; a thrombus was demonstrated only after protamine injection in 12 (mean APTT ratio 1.3 +/- 0.19) and before protamine injection in seven. In thirteen of these 19 dogs, 30 minutes separated the platelet injection from heparin therapy, while in six this duration was less than 30 minutes. In four of these six dogs, thrombi were demonstrated before protamine therapy and at APTT ratios greater than 3.0. Finally, 10 dogs were treated with a 100-U/kg bolus followed by a 3-hour, 50-U/kg/hour heparin infusion, after which the APTT was allowed to return to baseline values spontaneously. In all 10 dogs, a thrombus was demonstrated only after cessation of the heparin infusion, and at a mean APTT ratio of 1.4 +/- 0.15 times baseline. These results suggest that, except with very early platelet injection, platelet accretion by thrombi is consistently inhibited by heparin at APTT ratios greater than 2.5. Platelet accretion by venous thrombi occurs within narrow limits of heparin effect as reflected by the APTT

  12. Sensitivity of the activated partial thromboplastin time, the dilute Russell's viper venom time, and the kaolin clotting time for the detection of the lupus anticoagulant: a direct comparison using plasma dilutions.

    Science.gov (United States)

    Martin, B A; Branch, D W; Rodgers, G M

    1996-01-01

    Increasing dilutions of lupus anticoagulant (LA) plasmas from twelve patients were used to directly compare the sensitivity of four tests for LA. The tests evaluated were the modified Bell and Alton activated partial thromboplastin time (APTT), an APTT using a commercially prepared partial thromboplastin (Platelin LS APTT), a modified dilute Russell's viper venom time (DRVVT), and a modified kaolin clotting time (KCT). LAs were detected in all twelve plasmas by each of three tests and eleven of twelve plasmas in a fourth test when undiluted patient plasma was used. Repeating the tests after diluting the LA plasmas with normal platelet-free plasma (PFP) showed that the KCT was the most sensitive test for LA, detecting eleven of twelve LAs at a dilution of 10% patient plasma and ten of twelve LAs at a dilution of 5% patient plasma. The modified Bell and Alton APTT and the modified DRVVT had similar sensitivities at a patient plasma concentration of 10%, detecting seven of twelve and eight of twelve LAs, respectively. The Platelin LS APTT detected only four of twelve LAs at a patient plasma concentration of 10%. Our results indicate that the modified KCT is a sensitive method for the detection of LAs. The modified Bell and Alton APTT and the DRVVT were less sensitive.

  13. Is it acceptable to use coagulation plasma samples stored at room temperature and 4°C for 24 hours for additional prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and D-dimer testing?

    Science.gov (United States)

    Rimac, V; Coen Herak, D

    2017-10-01

    Coagulation laboratories are faced on daily basis with requests for additional testing in already analyzed fresh plasma samples. This prompted us to examine whether plasma samples stored at room temperature (RT), and 4°C for 24 hours can be accepted for additional prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen (Fbg), antithrombin (AT), and D-dimer testing. We measured PT, aPTT, Fbg in 50 and AT in 30 plasma samples with normal and pathological values, within 4 hours of blood collection (baseline results) and after 24-hours storage at RT (primary tubes), and 4°C (aliquots). D-dimer stability was investigated in 20 samples stored in primary tubes at 4°C. No statistically significant difference between baseline results and results in samples stored at RT and 4°C was observed for PT (P=.938), aPTT (P=.186), Fbg (P=.962), AT (P=.713), and D-dimers (P=.169). The highest median percentage changes were found for aPTT, being more pronounced for samples stored at 4°C (13.0%) than at RT (8.7%). Plasma samples stored both at RT and 4°C for 24 hours are acceptable for additional PT, Fbg, and AT testing. Plasma samples stored 24 hours in primary tubes at 4°C are suitable for D-dimer testing. © 2017 John Wiley & Sons Ltd.

  14. Valores de referência do tempo de protrombina (TP e tempo de tromboplastina parcial ativada (TTPa em cães Reference ranges of prothrombin time (PT and activated partial thromboplastin time (aPTT in dogs

    Directory of Open Access Journals (Sweden)

    Sonia Terezinha dos Anjos Lopes

    2005-04-01

    Full Text Available Os fatores de coagulação são parte integrante da hemostasia normal, e tanto as coagulopatias hereditárias como adquiridas que envolvem este sistema são de grande importância veterinária, geralmente evidenciadas por manifestações clínicas, tais como, petéquias, equimoses, hematomas e sangramentos tardios. O presente trabalho teve por objetivo a determinação dos valores de referência do tempo de protrombina (TP e tempo de tromboplastina parcial ativada (TTPa, por métodos manuais. Para tanto, utilizou-se "kits" para dosagens humanas, devido à inexistência de produtos similares de uso específico veterinário. Foram utilizados 40 cães clinicamente sadios, sem raça definida, machos ou fêmeas, de diferentes idades. As amostras sanguíneas foram de 2,5ml cada, colhidas por venopunção cefálica e acondicionadas em tubos de centrífuga contendo 0,25ml de citrato de sódio a 3,8%. O plasma foi imediatamente separado por centrifugação e as determinações de TP e TTPa foram realizadas utilizando-se "kits" comerciais "HemoStat Thromboplastin-SIª" e "HemoStat aPTT-El b", respectivamente. Os resultados obtidos foram de 6,87 ± 1,4 segundos para o TP com valores mínimo e máximo de 4,07 e 9,67, respectivamente, e de 15,10 ± 1,6 segundos para TTPa com valores mínimo e máximo de 11,9 e 18,3, respectivamente. Conclui-se, que os valores obtidos neste trabalho podem ser utilizados como referência. Os reagentes utilizados para plasma humano podem ser empregados para o plasma de cães.The coagulation factors are part of normal hemostasis, and both hereditary and acquired coagulopathies that involve this system have an important role in veterinary medicine, generally evidenced by clinical signs such as: petechias, ecchymosis, hematomas and late hemorrhagies. The objective of this experiment was to determine reference range values of prothrombin time (PT and activated partial thromboplastin time (aPTT, for manual methods. Human commercial

  15. Tempo de protrombina e de tromboplastina parcial ativada em caprinos criados extensivamente no Estado do Rio Grande do Norte Prothrombin time and activated partial thromboplastin time in goats raised extensively at Rio Grande do Norte State, Brazil

    Directory of Open Access Journals (Sweden)

    Benito Soto-Blanco

    2009-03-01

    Full Text Available Neste trabalho objetivou-se estabelecer os padrões de normalidade para tempo de protrombina (TP e tempo de tromboplastina parcial ativada (TTPA em caprinos criados extensivamente no estado do Rio Grande do Norte. Foram utilizados 40 caprinos SRD, 13 machos e 27 fêmeas, adultos, com idades entre 1 e 6 anos, todos clinicamente sadios. As amostras sanguíneas foram coletadas por venopunção jugular em tubos contendo citrato de sódio a 3,8%. O plasma foi imediatamente separado por centrifugação e refrigerado a ± 4ºC e, posteriormente, submetido às determinações de TP e TTPA por meio de métodos manuais utilizando kits comerciais. Os valores obtidos para caprinos da região, de 25,4 ± 0,90 e 39,5 ± 1,41 segundos para TP e TTPA, respectivamente, estavam dentro da normalidade.This study aimed to establish normal pattern for the prothrombin time (PT and activated partial thromboplastin time (APTT in goats extensively raised at Rio Grande do Norte state, Brazil. A total of 40 clinically healthy adult goats (13 males and 27 females aged 1 to 6 years-old was used. Blood samples were collected from jugular vein in tubes containing 3.8% of sodium citrate. The plasma was immediately separated by centrifugation and refrigerated at ± 4ºC and after submitted to PT e APTT determinations through manual methods using commercial kits. The results for goats in the region of 25.4 ± 0.90 and 39.5 ± 1.41 seconds, respectively, for PT and APTT were in an adequate range.

  16. Pneumatic tube system transport does not alter platelet function in optical and whole blood aggregometry, prothrombin time, activated partial thromboplastin time, platelet count and fibrinogen in patients on anti-platelet drug therapy

    Science.gov (United States)

    Enko, Dietmar; Mangge, Harald; Münch, Andreas; Niedrist, Tobias; Mahla, Elisabeth; Metzler, Helfried; Prüller, Florian

    2017-01-01

    Introduction The aim of this study was to assess pneumatic tube system (PTS) alteration on platelet function by the light transmission aggregometry (LTA) and whole blood aggregometry (WBA) method, and on the results of platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen. Materials and methods Venous blood was collected into six 4.5 mL VACUETTE® 9NC coagulation sodium citrate 3.8% tubes (Greiner Bio-One International GmbH, Kremsmünster, Austria) from 49 intensive care unit (ICU) patients on dual anti-platelet therapy and immediately hand carried to the central laboratory. Blood samples were divided into 2 Groups: Group 1 samples (N = 49) underwent PTS (4 m/s) transport from the central laboratory to the distant laboratory and back to the central laboratory, whereas Group 2 samples (N = 49) were excluded from PTS forces. In both groups, LTA and WBA stimulated with collagen, adenosine-5’-diphosphate (ADP), arachidonic acid (AA) and thrombin-receptor-activated-peptide 6 (TRAP-6) as well as platelet count, PT, APTT, and fibrinogen were performed. Results No statistically significant differences were observed between blood samples with (Group 1) and without (Group 2) PTS transport (P values from 0.064 – 0.968). The AA-induced LTA (bias: 68.57%) exceeded the bias acceptance limit of ≤ 25%. Conclusions Blood sample transportation with computer controlled PTS in our hospital had no statistically significant effects on platelet aggregation determined in patients with anti-platelet therapy. Although AA induced LTA showed a significant bias, the diagnostic accuracy was not influenced. PMID:28392742

  17. Evaluation of Prothrombin Time and Activated Partial ...

    African Journals Online (AJOL)

    and activated partial thromboplastin time (APTT) were investigated in treated and untreated diabetics as well as ... decrease the availability of these proteins which affect the clotting ... calcum rabbit brain thromboplastin reagent placed in.

  18. Partial Thromboplastin Time (PTT, aPTT)

    Science.gov (United States)

    ... Contact a Scientist Find Us On Social Media: Facebook Twitter Google Plus Footer Menu Home About This Site Contact Us Terms Of Use In The News Policies Editorial Review Board Partner | Advertise | License Sponsors and Partners Spread the Word Subscribe ...

  19. Avaliação do desempenho dos reagentes do tempo de tromboplastina parcial ativada utilizados para detectar o anticoagulante lúpico Assessment of the performance of reagents of activated partial thromboplastin time used to detect the lupus anticoagulant

    Directory of Open Access Journals (Sweden)

    Fernanda Chiuso

    2005-06-01

    Full Text Available INTRODUÇÃO: O anticoagulante lúpico é uma imunoglobulina pertencente à família dos anticorpos antifosfolípides. A sua ação in vitro é interferir nos testes de coagulação dependentes de fosfolípides. O tempo de tromboplastina parcial ativada (TTPA é um teste utilizado como screening na pesquisa do anticoagulante lúpico. Os reagentes utilizados neste teste apresentam grandes variações quanto à sensibilidade. OBJETIVO: Avaliar o desempenho dos reagentes do TTPA e detectar a presença do anticoagulante lúpico através de diferentes testes da coagulação. MATERIAL E MÉTODO: A pesquisa do anticoagulante lúpico foi realizada em 50 amostras plasmáticas de pacientes do sexo feminino através dos testes do TTPA, do tempo de coagulação do caulim (TCC, do tempo de tromboplastina parcial ativada diluída (TTPAd e do tempo do veneno da víbora de Russel diluído (TVVRd. Três cefalinas comerciais foram avaliadas pelos testes do TTPA e do TTPAd. Na comparação entre os reagentes estudados foi aplicado o cálculo do intervalo de confiança (95%. RESULTADOS: Os três reagentes avaliados apresentaram boa concordância e os métodos utilizados responderam bem à pesquisa do anticoagulante lúpico. DISCUSSÃO E CONCLUSÃO: As três cefalinas comerciais avaliadas podem ser utilizadas na rotina laboratorial para a pesquisa do anticoagulante lúpico.INTRODUCTION: The lupus anticoagulant is an immunoglobin which belongs to the antiphospholid antibodies family. Its in vitro function is to interfere with coagulation tests that are dependent on phospholipids. The activated partial thromboplastin time (APTT is a test used as screening on lupus anticoagulant research. Reagents used in this test demonstrate wide sensitivity ranges. OBJECTIVE: To assess the performance of APTT reagents and detect the presence of lupus anticoagulant through various coagulation tests. MATERIAL AND METHOD: The lupus anticoagulant research was performed in plasma from 50

  20. Qualification of a select one-stage activated partial thromboplastin time-based clotting assay and two chromogenic assays for the post-administration monitoring of nonacog beta pegol.

    Science.gov (United States)

    Tiefenbacher, S; Bohra, R; Amiral, J; Bowyer, A; Kitchen, S; Lochu, A; Rosén, S; Ezban, M

    2017-10-01

    Essentials Nonacog beta pegol (N9-GP) is an extended half-life, recombinant human factor IX (FIX). One-stage clotting (OSC) and chromogenic FIX activity assays were assessed for N9-GP recovery. OSC STA ® -Cephascreen ® , ROX FIX and BIOPHEN FIX chromogenic assays were qualified for N9-GP. Other extended half-life factor products should be assessed in a similar way prior to approval. Background Nonacog beta pegol (N9-GP) is an extended half-life, glycoPEGylated recombinant human factor IX that is under development for the prophylaxis and treatment of bleeding episodes in hemophilia B patients. Considerable reagent-dependent variability has been observed when one-stage clotting assays are used to measure the recovery of recombinant FIX products, including N9-GP. Objective To qualify select one-stage clotting and chromogenic FIX activity assays for measuring N9-GP recovery. Methods The accuracy and precision of the one-stage clotting assay (with the STA-Cephascreen activated partial thromboplastin [APTT] reagent) and the ROX Factor IX and BIOPHEN Factor IX chromogenic assays for measuring N9-GP recovery were assessed in N9-GP-spiked hemophilia B plasma samples in a systematic manner at three independent sites, with manufacturer-recommended protocols and/or site-specific assay setups, including different instruments. Results For each of the three FIX activity assays qualified on five different reagent-instrument systems, acceptable intra-assay and interassay accuracy and precision, dilution integrity, reagent robustness and freeze-thaw and short-term sample stabilities were demonstrated. The STA-Cephascreen assay showed a limited reportable range at one of the three qualification sites, and the BIOPHEN Factor IX assay showed suspect low-end sensitivity at one of the three qualification sites. An individual laboratory would account for these limitations by adjusting the assay's reportable range; thus, these findings are not considered to impact the respective

  1. The prothrombin time/international normalised ratio (PT/INR) line: derivation of local INR with commercial thromboplastins and coagulometers – two independent studies

    DEFF Research Database (Denmark)

    Poller, Leon; Ibrahim, S.; Keown, M.

    2011-01-01

    reagents, and from 7.0% to 2.6% with rabbit reagents. In the second study, deviation was reduced from 11.2% to 0.4% with human reagents by both local ISI calibration and the PT/INR Line. With rabbit reagents, 10.4% deviation was reduced to 1.1% with both procedures; 4.9% deviation was reduced to 0.5......Background: The WHO scheme for prothrombin time (PT) standardization has been limited in application, because of its difficulties in implementation, particularly the need for mandatory manual PT testing and for local provision of thromboplastin international reference preparations (IRP). Methods...... thromboplastins and coagulometers. INRs were compared with manual certified values with thromboplastin IRP from expert centres and in the second study also with INRs from local ISI calibrations. Results: In the first study with the PT/INR Line, 8.7% deviation from certified INRs was reduced to 1.1% with human...

  2. Relationship between plasma dabigatran concentration and activated partial thromboplastin time in Japanese patients with non-valvular atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Daiki Shimomura

    2015-08-01

    Conclusions: There was a significant correlation between plasma dabigatran concentrations and aPTT. Additionally, in daily clinical practice in Japan, plasma dabigatran concentrations and aPTT reached a peak in the 4-h post administration range. Considering the pharmacokinetics of dabigatran, aPTT can be used as an index for risk screening for excess dabigatran concentrations in Japanese patients with NVAF.

  3. Timed Testing under Partial Observability

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Li, Shuhao

    2009-01-01

    observability of SUT using a set of predicates over the TGA state space, and specify the test purposes in Computation Tree Logic (CTL) formulas. A recently developed partially observable timed game solver is used to generate winning strategies, which are used as test cases. We propose a conformance testing...

  4. Alternative pathways of thromboplastin-dependent activation of human factor X in plasma

    International Nuclear Information System (INIS)

    Marlar, R.A.; Griffin, J.H.

    1981-01-01

    To determine the interrelationships of the major coagulation pathways, the activation of 3H-labeled factor X in normal and various deficient human plasmas was evaluated when clotting was triggered by dilute rabbit or human thromboplastin. Various dilutions of thromboplastin and calcium were added to plasma samples containing 3H-factor X, and the time course of factor X activation was determined. At a 1/250 dilution of rabbit brain thromboplastin, the rate of factor X activation in plasmas deficient in factor VIII or factor IX was 10% of the activation rate of normal plasma or of factor XI deficient plasma. Reconstitution of the deficient plasmas with factors VIII or IX, respectively, reconstituted normal factor X activation. Similar results were obtained when various dilutions of human thromboplastin replaced the rabbit thromboplastin. From these plasma experiments, it is inferred that the dilute thromboplastin-dependent activation of factor X requires factors VII, IX, and VIII. An alternative extrinsic pathway that involves factors IX and VIII may be the physiologic extrinsic pathway and hence help to explain the consistent clinical observations of bleeding diatheses in patients deficient in factors IX or VIII

  5. [Interaction of human factor X with thromboplastin].

    Science.gov (United States)

    Kiselev, S V; Zubairov, D M; Timarbaev, V N

    2003-01-01

    The binding of 125I-labeled human factor X to native and papaine-treated tissue tromboplastin in the presence of CaCl2 or EDTA was studied. The Scatchard analysis suggests the existence of high (Kd=l,8 x10(-9) M) and low affinity binding sites on the thromboplastin surface. The removal of Ca2+ reduced affinity of factor X to the high affinity sites. This was accompanied by some increase of their number. Proteolysis by papaine decreased affinity of high affinity sites and caused the increase of their number in the presence of Ca2+. In the absence of Ca2+ the affinity remained unchanged, but the number of sites decreased. At low concentrations of factor X positive cooperativity for high affinity binding sites was observed. It did not depend on the presence of Ca2+. The results indirectly confirm the role of hydrophobic interactons in Ca2+ dependent binding of factor X to thromboplastin and the fact that heterogeneity of this binding is determined by mesophase structure of the thromboplastin phospholipids.

  6. International collaborative study for the calibration of proposed International Standards for thromboplastin, rabbit, plain and for thromboplastin, recombinant, human, plain

    DEFF Research Database (Denmark)

    van den Besselaar, A M H P; Chantarangkul, V; Angeloni, F

    2018-01-01

    BACKGROUND: The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current 4(th) International Standards are running low. Candidate replacement materia......) international standard (rTF/09). The candidate materials have been accepted by WHO as the 5(th) International Standards for thromboplastin, rabbit plain, and thromboplastin, recombinant, human, plain. This article is protected by copyright. All rights reserved.......BACKGROUND: The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current 4(th) International Standards are running low. Candidate replacement materials...... have been prepared. This report describes the calibration of the proposed 5(th) International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). METHODS: An international collaborative study was carried out for the assignment...

  7. Monitoring of treatment with vitamin K antagonists: recombinant thromboplastins are more sensitive to factor VII than tissue-extract thromboplastins.

    Science.gov (United States)

    Biedermann, J S; van den Besselaar, A M H P; de Maat, M P M; Leebeek, F W G; Kruip, M J H A

    2017-03-01

    Essentials Differences in sensitivity to factor VII (FVII) have been suggested between thromboplastins. FVII-induced International Normalized Ratio (INR) changes differ between commercial reagents. Recombinant human thromboplastins are more sensitive to FVII than tissue-extract thromboplastins. Thromboplastin choice may affect FVII-mediated INR stability. Background Differences regarding sensitivity to factor VII have been suggested for recombinant human and tissue-extract thromboplastins used for International Normalized Ratio (INR) measurement, but the evidence is scarce. Differences in FVII sensitivity are clinically relevant, as they can affect INR stability during treatment with vitamin K antagonists (VKAs). Objectives To determine whether commercial thromboplastins react differently to changes in FVII. Methods We studied the effect of addition of FVII on the INR in plasma by using three tissue-extract (Neoplastin C1+, Hepato Quick, and Thromborel S) and three recombinant human (Recombiplastin 2G, Innovin, and CoaguChek XS) thromboplastins. Three different concentrations of purified human FVII (0.006, 0.012 and 0.062 μg mL -1 plasma), or buffer, were added to five certified pooled plasmas of patients using VKAs (INR of 1.5-3.5). Changes in FVII activity were measured with two bioassays (Neoplastin and Recombiplastin), and relative INR changes were compared between reagents. Results After addition of 0.062 μg mL -1 FVII, FVII activity in the pooled plasmas increased by approximately 20% (Neoplastin) or 32% (Recombiplastin) relative to the activity in pooled normal plasma. All thromboplastins showed dose-dependent INR decreases. The relative INR change in the pooled plasmas significantly differed between the six thromboplastins. No differences were observed among recombinant or tissue-extract thromboplastins. Pooled results indicated that the FVII-induced INR change was greater for recombinant than for tissue-extract thromboplastins. Conclusions Differences

  8. Implementation of the ISTH classification of non-overt DIC in a thromboplastin induced rabbit model

    DEFF Research Database (Denmark)

    Berthelsen, Line Olrik; Kristensen, Annemarie Thuri; Wiinberg, Bo

    2009-01-01

    , but the scoring systems have rarely been applied to animal models of DIC. In this study, we use rabbit brain thromboplastin (thromboplastin) to induce DIC in a rabbit model and test the applicability of the ISTH criteria for standardized diagnosis of DIC. Cardiovascular and haematological parameters from rabbits......, either saline-injected or administered 0.625, 1.25, 2.5 or 5 mg thromboplastin/kg as a single bolus, were collected at four timepoints over a 90 minute period. All groups of rabbits were scored at each time point according to the ISTH diagnostic criteria for non-overt DIC. Injection of 5 mg...... and number of thrombi in lung vasculature was seen. The administration of a bolus of 1.25 - 2.5 mg thromboplastin/kg to rabbits induced a reproducible dose dependent model of non-overt DIC according to the ISTH diagnostic criteria. We conclude that the non-overt ISTH score can be applied to evaluate severity...

  9. 21 CFR 864.7900 - Thromboplastin generation test.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Thromboplastin generation test. 864.7900 Section 864.7900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7900...

  10. International collaborative study for the calibration of proposed International Standards for thromboplastin, rabbit, plain, and for thromboplastin, recombinant, human, plain.

    Science.gov (United States)

    van den Besselaar, A M H P; Chantarangkul, V; Angeloni, F; Binder, N B; Byrne, M; Dauer, R; Gudmundsdottir, B R; Jespersen, J; Kitchen, S; Legnani, C; Lindahl, T L; Manning, R A; Martinuzzo, M; Panes, O; Pengo, V; Riddell, A; Subramanian, S; Szederjesi, A; Tantanate, C; Herbel, P; Tripodi, A

    2018-01-01

    Essentials Two candidate International Standards for thromboplastin (coded RBT/16 and rTF/16) are proposed. International Sensitivity Index (ISI) of proposed standards was assessed in a 20-centre study. The mean ISI for RBT/16 was 1.21 with a between-centre coefficient of variation of 4.6%. The mean ISI for rTF/16 was 1.11 with a between-centre coefficient of variation of 5.7%. Background The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current Fourth International Standards are running low. Candidate replacement materials have been prepared. This article describes the calibration of the proposed Fifth International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). Methods An international collaborative study was carried out for the assignment of International Sensitivity Indexes (ISIs) to the candidate materials, according to the World Health Organization (WHO) guidelines for thromboplastins and plasma used to control oral anticoagulant therapy with vitamin K antagonists. Results Results were obtained from 20 laboratories. In several cases, deviations from the ISI calibration model were observed, but the average INR deviation attributabled to the model was not greater than 10%. Only valid ISI assessments were used to calculate the mean ISI for each candidate. The mean ISI for RBT/16 was 1.21 (between-laboratory coefficient of variation [CV]: 4.6%), and the mean ISI for rTF/16 was 1.11 (between-laboratory CV: 5.7%). Conclusions The between-laboratory variation of the ISI for candidate material RBT/16 was similar to that of the Fourth International Standard (RBT/05), and the between-laboratory variation of the ISI for candidate material rTF/16 was slightly higher than that of the Fourth International Standard (rTF/09). The candidate materials

  11. Partial synchronization in diffusively time-delay coupled oscillator networks

    NARCIS (Netherlands)

    Steur, E.; Oguchi, T.; Leeuwen, van C.; Nijmeijer, H.

    2012-01-01

    We study networks of diffusively time-delay coupled oscillatory units and we show that networks with certain symmetries can exhibit a form of incomplete synchronization called partial synchronization. We present conditions for the existence and stability of partial synchronization modes in networks

  12. Towards Just-In-Time Partial Evaluation of Prolog

    Science.gov (United States)

    Bolz, Carl Friedrich; Leuschel, Michael; Rigo, Armin

    We introduce a just-in-time specializer for Prolog. Just-in-time specialization attempts to unify of the concepts and benefits of partial evaluation (PE) and just-in-time (JIT) compilation. It is a variant of PE that occurs purely at runtime, which lazily generates residual code and is constantly driven by runtime feedback.

  13. Optimal moving grids for time-dependent partial differential equations

    Science.gov (United States)

    Wathen, A. J.

    1992-01-01

    Various adaptive moving grid techniques for the numerical solution of time-dependent partial differential equations were proposed. The precise criterion for grid motion varies, but most techniques will attempt to give grids on which the solution of the partial differential equation can be well represented. Moving grids are investigated on which the solutions of the linear heat conduction and viscous Burgers' equation in one space dimension are optimally approximated. Precisely, the results of numerical calculations of optimal moving grids for piecewise linear finite element approximation of PDE solutions in the least-squares norm are reported.

  14. Partial control of chaotic transients using escape times

    International Nuclear Information System (INIS)

    Sabuco, Juan; Zambrano, Samuel; Sanjuan, Miguel A F

    2010-01-01

    The partial control technique allows one to keep the trajectories of a dynamical system inside a region where there is a chaotic saddle and from which nearly all the trajectories diverge. Its main advantage is that this goal is achieved even if the corrections applied to the trajectories are smaller than the action of environmental noise on the dynamics, a counterintuitive result that is obtained by using certain safe sets. Using the Henon map as a paradigm, we show here the deep relationship between the safe sets and the sets of points with different escape times, the escape time sets. Furthermore, we show that it is possible to find certain extended safe sets that can be used instead of the safe sets in the partial control technique. Numerical simulations confirm our findings and show that in some situations, the use of extended safe sets can be more advantageous.

  15. Spectral methods for time dependent partial differential equations

    Science.gov (United States)

    Gottlieb, D.; Turkel, E.

    1983-01-01

    The theory of spectral methods for time dependent partial differential equations is reviewed. When the domain is periodic Fourier methods are presented while for nonperiodic problems both Chebyshev and Legendre methods are discussed. The theory is presented for both hyperbolic and parabolic systems using both Galerkin and collocation procedures. While most of the review considers problems with constant coefficients the extension to nonlinear problems is also discussed. Some results for problems with shocks are presented.

  16. Partial Synchronization Manifolds for Linearly Time-Delay Coupled Systems

    OpenAIRE

    Steur, Erik; van Leeuwen, Cees; Michiels, Wim

    2014-01-01

    Sometimes a network of dynamical systems shows a form of incomplete synchronization characterized by synchronization of some but not all of its systems. This type of incomplete synchronization is called partial synchronization. Partial synchronization is associated with the existence of partial synchronization manifolds, which are linear invariant subspaces of C, the state space of the network of systems. We focus on partial synchronization manifolds in networks of system...

  17. Group formalism of Lie transformations to time-fractional partial ...

    Indian Academy of Sciences (India)

    Lie symmetry analysis; Fractional partial differential equation; Riemann–Liouville fractional derivative ... science and engineering. It is known that while ... differential equations occurring in different areas of applied science [11,14]. The Lie ...

  18. [Significant decrease in factor VII activity by tissue thromboplastin derived from rabbit brain in a patient with congenital factor VII deficiency (FVII Padua)].

    Science.gov (United States)

    Sekiya, Akiko; Morishita, Eriko; Maruyama, Keiko; Asakura, Hidesaku; Nakao, Shinji; Ohtake, Shigeki

    2012-03-01

    Congenital factor VII (FVII) deficiency is a bleeding disorder that requires optimal hemostatic management for each case due to its wide variety of bleeding symptoms. We experienced a patient with inherited FVII deficiency who demonstrated different FVII activities depending on tissue thromboplastins used for assays. An 82-year-old woman without any episodes of abnormal bleeding was found to have different FVII activities of 1.4% and 32% when assayed using thromboplastins from rabbit brain and human placenta, respectively. DNA sequencing analysis revealed a homozygous missense mutation of G10828A (FVII Padua) that caused an amino acid substitution of Arg304 to Gln (R304Q). Carriers of 304Q alleles are usually clinically asymptomatic and do not require FVII replacement therapies even in cases of homozygotes. In case a prolonged prothrombin time or reduced FVII activity is detected, re-examination using thromboplastins of other sources can be helpful for preliminary diagnosis of R304Q, in order to prevent unnecessary FVII replacement therapies.

  19. Can Real-Time Systems Benefit from Dynamic Partial Reconfiguration?

    DEFF Research Database (Denmark)

    Pezzarossa, Luca; Kristensen, Andreas Toftegaard; Schoeberl, Martin

    2017-01-01

    In real-time systems, a solution where hardware accelerators are used to implement computationally intensive tasks can be easier to analyze, in terms of worst-case execution time (WCET), than a pure software solution. However, when using FPGAs, the amount and the complexity of the hardware...... hardware accelerators in real-time systems and presents an experimental analysis of the trade-offs between hardware utilization and WCET increase due to the reconfiguration time overhead of DPR. We also investigate the trade-off between the use of multiple specialized accelerators combined with DPR instead...

  20. Influence of the centrifuge time of primary plasma tubes on routine coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Manzato, Franco; Guidi, Gian Cesare

    2007-07-01

    Preparation of blood specimens is a major bottleneck in the laboratory throughput. Reliable strategies for reducing the time required for specimen processing without affecting quality should be acknowledged, especially for laboratories performing stat analyses. The present investigation was planned to establish a minimal suitable centrifuge time for primary samples collected for routine coagulation testing. Five sequential primary vacuum tubes containing 0.109 mol/l buffered trisodium citrate were collected from 10 volunteers and were immediately centrifuged on a conventional centrifuge at 1500 x g, at room temperature for 1, 2, 5, 10 and 15 min, respectively. Hematological and routine coagulation testing, including prothrombin time, activated partial thromboplastin time and fibrinogen, were performed. The centrifugation time was inversely associated with residual blood cell elements in plasma, especially platelets. Statistically significant variations from the reference 15-min centrifuge specimens were observed for fibrinogen in samples centrifuged for 5 min at most and for the activated partial thromboplastin time in samples centrifuged for 2 min at most. Meaningful biases related to the desirable bias were observed for fibrinogen in samples centrifuged for 2 min at most, and for the activated partial thromboplastin time in samples centrifuged for 1 min at most. According to our experimental conditions, a 5-10 min centrifuge time at 1500 x g may be suitable for primary tubes collected for routine coagulation testing.

  1. Imprecise results: Utilizing partial computations in real-time systems

    Science.gov (United States)

    Lin, Kwei-Jay; Natarajan, Swaminathan; Liu, Jane W.-S.

    1987-01-01

    In real-time systems, a computation may not have time to complete its execution because of deadline requirements. In such cases, no result except the approximate results produced by the computations up to that point will be available. It is desirable to utilize these imprecise results if possible. Two approaches are proposed to enable computations to return imprecise results when executions cannot be completed normally. The milestone approach records results periodically, and if a deadline is reached, returns the last recorded result. The sieve approach demarcates sections of code which can be skipped if the time available is insufficient. By using these approaches, the system is able to produce imprecise results when deadlines are reached. The design of the Concord project is described which supports imprecise computations using these techniques. Also presented is a general model of imprecise computations using these techniques, as well as one which takes into account the influence of the environment, showing where the latter approach fits into this model.

  2. Higher order multi-term time-fractional partial differential equations involving Caputo-Fabrizio derivative

    Directory of Open Access Journals (Sweden)

    Erkinjon Karimov

    2017-10-01

    Full Text Available In this work we discuss higher order multi-term partial differential equation (PDE with the Caputo-Fabrizio fractional derivative in time. Using method of separation of variables, we reduce fractional order partial differential equation to the integer order. We represent explicit solution of formulated problem in particular case by Fourier series.

  3. Higher order multi-term time-fractional partial differential equations involving Caputo-Fabrizio derivative

    OpenAIRE

    Erkinjon Karimov; Sardor Pirnafasov

    2017-01-01

    In this work we discuss higher order multi-term partial differential equation (PDE) with the Caputo-Fabrizio fractional derivative in time. Using method of separation of variables, we reduce fractional order partial differential equation to the integer order. We represent explicit solution of formulated problem in particular case by Fourier series.

  4. Partial Finite-Time Synchronization of Switched Stochastic Chua's Circuits via Sliding-Mode Control

    Directory of Open Access Journals (Sweden)

    Zhang-Lin Wan

    2011-01-01

    Full Text Available This paper considers the problem of partial finite-time synchronization between switched stochastic Chua's circuits accompanied by a time-driven switching law. Based on the Ito formula and Lyapunov stability theory, a sliding-mode controller is developed to guarantee the synchronization of switched stochastic master-slave Chua's circuits and for the mean of error states to obtain the partial finite-time stability. Numerical simulations demonstrate the effectiveness of the proposed methods.

  5. Failure to detect variant (CRM+) plasma thromboplastin antecedent (factor XI) molecules in hereditary plasma thromboplastin antecedent deficiency: a study of 125 patients of several ethnic backgrounds.

    Science.gov (United States)

    Saito, H; Ratnoff, O D; Bouma, B N; Seligsohn, U

    1985-12-01

    Plasma samples of 125 patients from 80 kindreds with hereditary plasma thromboplastin antecedent (PTA, factor XI) deficiency were tested by factor XI radioimmunoassay (RIA) and electroimmunoassay (EIA) in an attempt to detect variant molecules. Ninety-six patients (70 kindreds) were Jewish, and 29 (10 kindreds) were of other ethnic backgrounds, namely, Japanese, black American, Korean, Arab, Indian, and English. Seventy-eight patients were homozygotes, and 47 were heterozygotes. Both non-Jewish homozygotes and heterozygotes had lower factor XI activity than respective Jewish subjects. Twenty-eight homozygotes whose factor XI clotting activities (XI:C) were 1.5% to 13% had factor XI-related antigen (XI:RAG) levels less than 10% by EIA. In 72 homozygotes, including 22 patients who were also tested with EIA, XI:C was 2.9% +/- 3.0% (mean +/- SD) and XI:RAG tested by RIA, 2.9% +/- 3.0%. In 47 heterozygotes, XI:C and XI:RAG tested by RIA were 51.9% +/- 16.6% and 51.0% +/- 16.2%, respectively. Similar results were obtained when only unrelated patients (62 homozygotes and 27 heterozygotes) were analyzed. There was a highly significant correlation between XI:C and XI:RAG (RIA) in 38 homozygotes and 47 heterozygotes (r = 0.94, n = 85, P less than 0.001). Thus, we failed to identify functionally abnormal factor XI molecules (CRM+ variant) in these patients with hereditary factor XI deficiency.

  6. Effects of partial reinforcement and time between reinforced trials on terminal response rate in pigeon autoshaping.

    Science.gov (United States)

    Gottlieb, Daniel A

    2006-03-01

    Partial reinforcement often leads to asymptotically higher rates of responding and number of trials with a response than does continuous reinforcement in pigeon autoshaping. However, comparisons typically involve a partial reinforcement schedule that differs from the continuous reinforcement schedule in both time between reinforced trials and probability of reinforcement. Two experiments examined the relative contributions of these two manipulations to asymptotic response rate. Results suggest that the greater responding previously seen with partial reinforcement is primarily due to differential probability of reinforcement and not differential time between reinforced trials. Further, once established, differences in responding are resistant to a change in stimulus and contingency. Secondary response theories of autoshaped responding (theories that posit additional response-augmenting or response-attenuating mechanisms specific to partial or continuous reinforcement) cannot fully accommodate the current body of data. It is suggested that researchers who study pigeon autoshaping train animals on a common task prior to training them under different conditions.

  7. New Solutions of Three Nonlinear Space- and Time-Fractional Partial Differential Equations in Mathematical Physics

    International Nuclear Information System (INIS)

    Yao Ruo-Xia; Wang Wei; Chen Ting-Hua

    2014-01-01

    Motivated by the widely used ansätz method and starting from the modified Riemann—Liouville derivative together with a fractional complex transformation that can be utilized to transform nonlinear fractional partial differential equations to nonlinear ordinary differential equations, new types of exact traveling wave solutions to three important nonlinear space- and time-fractional partial differential equations are obtained simultaneously in terms of solutions of a Riccati equation. The results are new and first reported in this paper. (general)

  8. Separation of time-based and trial-based accounts of the partial reinforcement extinction effect.

    Science.gov (United States)

    Bouton, Mark E; Woods, Amanda M; Todd, Travis P

    2014-01-01

    Two appetitive conditioning experiments with rats examined time-based and trial-based accounts of the partial reinforcement extinction effect (PREE). In the PREE, the loss of responding that occurs in extinction is slower when the conditioned stimulus (CS) has been paired with a reinforcer on some of its presentations (partially reinforced) instead of every presentation (continuously reinforced). According to a time-based or "time-accumulation" view (e.g., Gallistel and Gibbon, 2000), the PREE occurs because the organism has learned in partial reinforcement to expect the reinforcer after a larger amount of time has accumulated in the CS over trials. In contrast, according to a trial-based view (e.g., Capaldi, 1967), the PREE occurs because the organism has learned in partial reinforcement to expect the reinforcer after a larger number of CS presentations. Experiment 1 used a procedure that equated partially and continuously reinforced groups on their expected times to reinforcement during conditioning. A PREE was still observed. Experiment 2 then used an extinction procedure that allowed time in the CS and the number of trials to accumulate differentially through extinction. The PREE was still evident when responding was examined as a function of expected time units to the reinforcer, but was eliminated when responding was examined as a function of expected trial units to the reinforcer. There was no evidence that the animal responded according to the ratio of time accumulated during the CS in extinction over the time in the CS expected before the reinforcer. The results thus favor a trial-based account over a time-based account of extinction and the PREE. This article is part of a Special Issue entitled: Associative and Temporal Learning. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Plasma thromboplastin antecedent (PTA, factor XI): a specific and sensitive radioimmunoassay

    International Nuclear Information System (INIS)

    Saito, H.; Goldsmith, G.H. Jr.

    1977-01-01

    A specific, sensitive, and reproducible radioimmunoassay for human plasma thromboplastin antecedent (PTA, factor XI) has been developed with purified PTA and monospecific rabbit antiserum. Precise measurements of PTA antigen were possible for concentrations as low as 0.3% of that in normal pooled plasma. Normal plasma contained approximately 6 μg PTA/ml. A good correlation (correlation coefficient 0.68) existed between the PTA procoagulant assays and radioimmunoassays among 50 normal adults (25 males and 25 females). PTA antigen was markedly reduced in plasma of 13 patients with congenital homozygous PTA deficiency (range <0.003-0.128 U/ml) and 9 patients with hepatic cirrhosis (0.35 +- 0.17 U/ml), but was normal in those of 9 patients under treatment with warfarin, 8 patients with disseminated intravascular coagulation and 16 patients with other congenital clotting factor abnormalities, including prekallikrein deficiency (Fletcher trait) and high molecular weight kininogen deficiency

  10. Combining instruction prefetching with partial cache locking to improve WCET in real-time systems.

    Directory of Open Access Journals (Sweden)

    Fan Ni

    Full Text Available Caches play an important role in embedded systems to bridge the performance gap between fast processor and slow memory. And prefetching mechanisms are proposed to further improve the cache performance. While in real-time systems, the application of caches complicates the Worst-Case Execution Time (WCET analysis due to its unpredictable behavior. Modern embedded processors often equip locking mechanism to improve timing predictability of the instruction cache. However, locking the whole cache may degrade the cache performance and increase the WCET of the real-time application. In this paper, we proposed an instruction-prefetching combined partial cache locking mechanism, which combines an instruction prefetching mechanism (termed as BBIP with partial cache locking to improve the WCET estimates of real-time applications. BBIP is an instruction prefetching mechanism we have already proposed to improve the worst-case cache performance and in turn the worst-case execution time. The estimations on typical real-time applications show that the partial cache locking mechanism shows remarkable WCET improvement over static analysis and full cache locking.

  11. Combining instruction prefetching with partial cache locking to improve WCET in real-time systems.

    Science.gov (United States)

    Ni, Fan; Long, Xiang; Wan, Han; Gao, Xiaopeng

    2013-01-01

    Caches play an important role in embedded systems to bridge the performance gap between fast processor and slow memory. And prefetching mechanisms are proposed to further improve the cache performance. While in real-time systems, the application of caches complicates the Worst-Case Execution Time (WCET) analysis due to its unpredictable behavior. Modern embedded processors often equip locking mechanism to improve timing predictability of the instruction cache. However, locking the whole cache may degrade the cache performance and increase the WCET of the real-time application. In this paper, we proposed an instruction-prefetching combined partial cache locking mechanism, which combines an instruction prefetching mechanism (termed as BBIP) with partial cache locking to improve the WCET estimates of real-time applications. BBIP is an instruction prefetching mechanism we have already proposed to improve the worst-case cache performance and in turn the worst-case execution time. The estimations on typical real-time applications show that the partial cache locking mechanism shows remarkable WCET improvement over static analysis and full cache locking.

  12. Strong normalization by type-directed partial evaluation and run-time code generation

    DEFF Research Database (Denmark)

    Balat, Vincent; Danvy, Olivier

    1998-01-01

    We investigate the synergy between type-directed partial evaluation and run-time code generation for the Caml dialect of ML. Type-directed partial evaluation maps simply typed, closed Caml values to a representation of their long βη-normal form. Caml uses a virtual machine and has the capability...... to load byte code at run time. Representing the long βη-normal forms as byte code gives us the ability to strongly normalize higher-order values (i.e., weak head normal forms in ML), to compile the resulting strong normal forms into byte code, and to load this byte code all in one go, at run time. We...... conclude this note with a preview of our current work on scaling up strong normalization by run-time code generation to the Caml module language....

  13. A higher order numerical method for time fractional partial differential equations with nonsmooth data

    Science.gov (United States)

    Xing, Yanyuan; Yan, Yubin

    2018-03-01

    Gao et al. [11] (2014) introduced a numerical scheme to approximate the Caputo fractional derivative with the convergence rate O (k 3 - α), 0 equation is sufficiently smooth, Lv and Xu [20] (2016) proved by using energy method that the corresponding numerical method for solving time fractional partial differential equation has the convergence rate O (k 3 - α), 0 equation has low regularity and in this case the numerical method fails to have the convergence rate O (k 3 - α), 0 quadratic interpolation polynomials. Based on this scheme, we introduce a time discretization scheme to approximate the time fractional partial differential equation and show by using Laplace transform methods that the time discretization scheme has the convergence rate O (k 3 - α), 0 0 for smooth and nonsmooth data in both homogeneous and inhomogeneous cases. Numerical examples are given to show that the theoretical results are consistent with the numerical results.

  14. Strong Normalization by Type-Directed Partial Evaluation and Run-Time Code Generation

    DEFF Research Database (Denmark)

    Balat, Vincent; Danvy, Olivier

    1997-01-01

    We investigate the synergy between type-directed partial evaluation and run-time code generation for the Caml dialect of ML. Type-directed partial evaluation maps simply typed, closed Caml values to a representation of their long βη-normal form. Caml uses a virtual machine and has the capability...... to load byte code at run time. Representing the long βη-normal forms as byte code gives us the ability to strongly normalize higher-order values (i.e., weak head normal forms in ML), to compile the resulting strong normal forms into byte code, and to load this byte code all in one go, at run time. We...... conclude this note with a preview of our current work on scaling up strong normalization by run-time code generation to the Caml module language....

  15. Conservation laws for certain time fractional nonlinear systems of partial differential equations

    Science.gov (United States)

    Singla, Komal; Gupta, R. K.

    2017-12-01

    In this study, an extension of the concept of nonlinear self-adjointness and Noether operators is proposed for calculating conserved vectors of the time fractional nonlinear systems of partial differential equations. In our recent work (J Math Phys 2016; 57: 101504), by proposing the symmetry approach for time fractional systems, the Lie symmetries for some fractional nonlinear systems have been derived. In this paper, the obtained infinitesimal generators are used to find conservation laws for the corresponding fractional systems.

  16. Partial path column generation for the vehicle routing problem with time windows

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Jepsen, Mads Kehlet

    2009-01-01

    This paper presents a column generation algorithm for the Vehicle Routing Problem with Time Windows (VRPTW). Traditionally, column generation models of the VRPTW have consisted of a Set Partitioning master problem with each column representing a route, i.e., a resource feasible path starting...... and ending at the depot. Elementary routes (no customer visited more than once) have shown superior results on difficult instances (less restrictive capacity and time windows). However, the pricing problems do not scale well when the number of feasible routes increases, i.e., when a route may contain a large...... number of customers. We suggest to relax that ‘each column is a route’ into ‘each column is a part of the giant tour’; a so-called partial path, i.e., not necessarily starting and ending in the depot. This way, the length of the partial path can be bounded and a better control of the size of the solution...

  17. Constructing and predicting solitary pattern solutions for nonlinear time-fractional dispersive partial differential equations

    Science.gov (United States)

    Arqub, Omar Abu; El-Ajou, Ahmad; Momani, Shaher

    2015-07-01

    Building fractional mathematical models for specific phenomena and developing numerical or analytical solutions for these fractional mathematical models are crucial issues in mathematics, physics, and engineering. In this work, a new analytical technique for constructing and predicting solitary pattern solutions of time-fractional dispersive partial differential equations is proposed based on the generalized Taylor series formula and residual error function. The new approach provides solutions in the form of a rapidly convergent series with easily computable components using symbolic computation software. For method evaluation and validation, the proposed technique was applied to three different models and compared with some of the well-known methods. The resultant simulations clearly demonstrate the superiority and potentiality of the proposed technique in terms of the quality performance and accuracy of substructure preservation in the construct, as well as the prediction of solitary pattern solutions for time-fractional dispersive partial differential equations.

  18. A Controller for Dynamic Partial Reconfiguration in FPGA-Based Real-Time Systems

    DEFF Research Database (Denmark)

    Pezzarossa, Luca; Schoeberl, Martin; Sparsø, Jens

    2017-01-01

    -source DPR controller specially developed for hard real-time systems and prototyped in connection with the open-source multi-core platform for real-time applications T-CREST. The controller enables a processor to perform reconfiguration in a time-predictable manner and supports different operating modes......In real-time systems, the use of hardware accelerators can lead to a worst-case execution-time speed-up, to a simplification of its analysis, and to a reduction of its pessimism. When using FPGA technology, dynamic partial reconfiguration (DPR) can be used to minimize the area, by only loading....... The paper also presents a software tool for bitstream conversion, compression, and for reconfiguration time analysis. The DPR controller is evaluated in terms of hardware cost, operating frequency, speed, and bitstream compression ratio vs. reconfiguration time trade-off. A simple application example...

  19. Effects of partial time delays on phase synchronization in Watts-Strogatz small-world neuronal networks

    Science.gov (United States)

    Sun, Xiaojuan; Perc, Matjaž; Kurths, Jürgen

    2017-05-01

    In this paper, we study effects of partial time delays on phase synchronization in Watts-Strogatz small-world neuronal networks. Our focus is on the impact of two parameters, namely the time delay τ and the probability of partial time delay pdelay, whereby the latter determines the probability with which a connection between two neurons is delayed. Our research reveals that partial time delays significantly affect phase synchronization in this system. In particular, partial time delays can either enhance or decrease phase synchronization and induce synchronization transitions with changes in the mean firing rate of neurons, as well as induce switching between synchronized neurons with period-1 firing to synchronized neurons with period-2 firing. Moreover, in comparison to a neuronal network where all connections are delayed, we show that small partial time delay probabilities have especially different influences on phase synchronization of neuronal networks.

  20. Detrended partial cross-correlation analysis of two nonstationary time series influenced by common external forces

    Science.gov (United States)

    Qian, Xi-Yuan; Liu, Ya-Min; Jiang, Zhi-Qiang; Podobnik, Boris; Zhou, Wei-Xing; Stanley, H. Eugene

    2015-06-01

    When common factors strongly influence two power-law cross-correlated time series recorded in complex natural or social systems, using detrended cross-correlation analysis (DCCA) without considering these common factors will bias the results. We use detrended partial cross-correlation analysis (DPXA) to uncover the intrinsic power-law cross correlations between two simultaneously recorded time series in the presence of nonstationarity after removing the effects of other time series acting as common forces. The DPXA method is a generalization of the detrended cross-correlation analysis that takes into account partial correlation analysis. We demonstrate the method by using bivariate fractional Brownian motions contaminated with a fractional Brownian motion. We find that the DPXA is able to recover the analytical cross Hurst indices, and thus the multiscale DPXA coefficients are a viable alternative to the conventional cross-correlation coefficient. We demonstrate the advantage of the DPXA coefficients over the DCCA coefficients by analyzing contaminated bivariate fractional Brownian motions. We calculate the DPXA coefficients and use them to extract the intrinsic cross correlation between crude oil and gold futures by taking into consideration the impact of the U.S. dollar index. We develop the multifractal DPXA (MF-DPXA) method in order to generalize the DPXA method and investigate multifractal time series. We analyze multifractal binomial measures masked with strong white noises and find that the MF-DPXA method quantifies the hidden multifractal nature while the multifractal DCCA method fails.

  1. Analytical solutions to time-fractional partial differential equations in a two-dimensional multilayer annulus

    Science.gov (United States)

    Chen, Shanzhen; Jiang, Xiaoyun

    2012-08-01

    In this paper, analytical solutions to time-fractional partial differential equations in a multi-layer annulus are presented. The final solutions are obtained in terms of Mittag-Leffler function by using the finite integral transform technique and Laplace transform technique. In addition, the classical diffusion equation (α=1), the Helmholtz equation (α→0) and the wave equation (α=2) are discussed as special cases. Finally, an illustrative example problem for the three-layer semi-circular annular region is solved and numerical results are presented graphically for various kind of order of fractional derivative.

  2. "Real-Time Optical Laboratory Linear Algebra Solution Of Partial Differential Equations"

    Science.gov (United States)

    Casasent, David; Jackson, James

    1986-03-01

    A Space Integrating (SI) Optical Linear Algebra Processor (OLAP) employing space and frequency-multiplexing, new partitioning and data flow, and achieving high accuracy performance with a non base-2 number system is described. Laboratory data on the performance of this system and the solution of parabolic Partial Differential Equations (PDEs) is provided. A multi-processor OLAP system is also described for the first time. It use in the solution of multiple banded matrices that frequently arise is then discussed. The utility and flexibility of this processor compared to digital systolic architectures should be apparent.

  3. Life time test of a partial model of HTGR helium-helium heat exchanger

    International Nuclear Information System (INIS)

    Kitagawa, Masaki; Hattori, Hiroshi; Ohtomo, Akira; Teramae, Tetsuo; Hamanaka, Junichi; Itoh, Mitsuyoshi; Urabe, Shigemi

    1984-01-01

    Authors had proposed a design guide for the HTGR components and applied it to the design and construction of the 1.5 Mwt helium heat exchanger test loop for the nuclear steel making under the financial support of the Japanese Ministry of International Trade and Industry. In order to assure that the design method covers all the conceivable failure mode and has enough safety margin, a series of life time tests of partial model may be needed. For this project, three types of model tests were performed. A life time test of a partial model of the center manifold pipe and eight heat exchanger tubes were described in this report. A damage criterion with a set of material constants and a simplified method for stress-strain analysis for stub tube under three dimensional load were newly developed and used to predict the lives of each tube. The predicted lives were compared with the experimental lives and good agreement was found between the two. The life time test model was evaluated according to the proposed design guide and it was found that the guide has a safety factor of approximately 200 in life for this particular model. (author)

  4. Time-variant partial directed coherence in analysis of the cardiovascular system. A methodological study

    International Nuclear Information System (INIS)

    Milde, T; Schwab, K; Walther, M; Eiselt, M; Witte, H; Schelenz, C; Voss, A

    2011-01-01

    Time-variant partial directed coherence (tvPDC) is used for the first time in a multivariate analysis of heart rate variability (HRV), respiratory movements (RMs) and (systolic) arterial blood pressure. It is shown that respiration-related HRV components which also occur at other frequencies besides the RM frequency (= respiratory sinus arrhythmia, RSA) can be identified. These additional components are known to be an effect of the 'half-the-mean-heart-rate-dilemma' ('cardiac aliasing' CA). These CA components may contaminate the entire frequency range of HRV and can lead to misinterpretation of the RSA analysis. TvPDC analysis of simulated and clinical data (full-term neonates and sedated patients) reveals these contamination effects and, in addition, the respiration-related CA components can be separated from the RSA component and the Traube–Hering–Mayer wave. It can be concluded that tvPDC can be beneficially applied to avoid misinterpretations in HRV analyses as well as to quantify partial correlative interaction properties between RM and RSA

  5. Availability and mean life time prediction of multistage degraded system with partial repairs

    International Nuclear Information System (INIS)

    Pham, Hoang; Suprasad, A.; Misra, R.B.

    1997-01-01

    In some environments, components might not always fail fully, but can degrade, and there can be multiple stages of degradation. In such cases, the efficiency of the system may decrease. After a certain stage of degradation the efficiency of the system may decrease to an unacceptable limit and can be considered as a total failure. However, the system can fail randomly from any stage. and can be repaired. Further, the repair action cannot bring the system to the good stage, but can make it operational and the failure rate of the system will, therefore, remain the same as before the failure. In this study, we present a model for predicting the reliability, availability, mean life time, and mean time to first failure of multistage degraded systems with partial repairs. In the analysis, state dependent transition rates for the degradation process, as well as repair processes, are considered. A numerical example is provided to illustrate the results

  6. Estimating the time and temperature relationship for causation of deep-partial thickness skin burns.

    Science.gov (United States)

    Abraham, John P; Plourde, Brian; Vallez, Lauren; Stark, John; Diller, Kenneth R

    2015-12-01

    The objective of this study is to develop and present a simple procedure for evaluating the temperature and exposure-time conditions that lead to causation of a deep-partial thickness burn and the effect that the immediate post-burn thermal environment can have on the process. A computational model has been designed and applied to predict the time required for skin burns to reach a deep-partial thickness level of injury. The model includes multiple tissue layers including the epidermis, dermis, hypodermis, and subcutaneous tissue. Simulated exposure temperatures ranged from 62.8 to 87.8°C (145-190°F). Two scenarios were investigated. The first and worst case scenario was a direct exposure to water (characterized by a large convection coefficient) with the clothing left on the skin following the exposure. A second case consisted of a scald insult followed immediately by the skin being washed with cool water (20°C). For both cases, an Arrhenius injury model was applied whereby the extent and depth of injury were calculated and compared for the different post-burn treatments. In addition, injury values were compared with experiment data from the literature to assess verification of the numerical methodology. It was found that the clinical observations of injury extent agreed with the calculated values. Furthermore, inundation with cool water decreased skin temperatures more quickly than the clothing insulating case and led to a modest decrease in the burn extent. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  7. Progranulin inhibits platelet aggregation and prolongs bleeding time in rats.

    Science.gov (United States)

    Al-Yahya, A M; Al-Masri, A A; El Eter, E A; Hersi, A; Lateef, R; Mawlana, O

    2018-05-01

    Several adipokines secreted by adipose tissue have an anti-thrombotic and anti-atherosclerotic function. Recently identified adipokine progranulin was found to play a protective role in atherosclerosis. Bearing in mind the central role of platelets in inflammation and atherosclerosis, we aimed, in this study, to examine the effect of progranulin on platelet function and coagulation profile in rats. Healthy male albino Wistar rats weighing (250-300 g) were divided into 4 groups. Three groups were given increasing doses of progranulin (0.001 µg, 0.01 µg, and 0.1 µg) intraperitoneally, while the control group received phosphate-buffered saline (PBS). Bleeding time, prothrombin time, activated partial thromboplastin time and platelet aggregation responses to adenosine diphosphate and arachidonic acid were assessed. Administration of progranulin resulted in a significant inhibition of platelet aggregation in response to both adenosine diphosphate, and arachidonic acid. Bleeding time, prothrombin time and activated partial thromboplastin time were significantly prolonged in all groups that received progranulin, in particular, the 0.1 µg dose, in comparison to the control group. This preliminary data is first suggesting that the antiplatelet and anticoagulant action of progranulin could have a physiological protective function against thrombotic disorders associated with obesity and atherosclerosis. However, these results merit further exploration.

  8. Soft sensor modelling by time difference, recursive partial least squares and adaptive model updating

    International Nuclear Information System (INIS)

    Fu, Y; Xu, O; Yang, W; Zhou, L; Wang, J

    2017-01-01

    To investigate time-variant and nonlinear characteristics in industrial processes, a soft sensor modelling method based on time difference, moving-window recursive partial least square (PLS) and adaptive model updating is proposed. In this method, time difference values of input and output variables are used as training samples to construct the model, which can reduce the effects of the nonlinear characteristic on modelling accuracy and retain the advantages of recursive PLS algorithm. To solve the high updating frequency of the model, a confidence value is introduced, which can be updated adaptively according to the results of the model performance assessment. Once the confidence value is updated, the model can be updated. The proposed method has been used to predict the 4-carboxy-benz-aldehyde (CBA) content in the purified terephthalic acid (PTA) oxidation reaction process. The results show that the proposed soft sensor modelling method can reduce computation effectively, improve prediction accuracy by making use of process information and reflect the process characteristics accurately. (paper)

  9. FPGA Implementation of Real-Time Compressive Sensing with Partial Fourier Dictionary

    Directory of Open Access Journals (Sweden)

    Yinghui Quan

    2016-01-01

    Full Text Available This paper presents a novel real-time compressive sensing (CS reconstruction which employs high density field-programmable gate array (FPGA for hardware acceleration. Traditionally, CS can be implemented using a high-level computer language in a personal computer (PC or multicore platforms, such as graphics processing units (GPUs and Digital Signal Processors (DSPs. However, reconstruction algorithms are computing demanding and software implementation of these algorithms is extremely slow and power consuming. In this paper, the orthogonal matching pursuit (OMP algorithm is refined to solve the sparse decomposition optimization for partial Fourier dictionary, which is always adopted in radar imaging and detection application. OMP reconstruction can be divided into two main stages: optimization which finds the closely correlated vectors and least square problem. For large scale dictionary, the implementation of correlation is time consuming since it often requires a large number of matrix multiplications. Also solving the least square problem always needs a scalable matrix decomposition operation. To solve these problems efficiently, the correlation optimization is implemented by fast Fourier transform (FFT and the large scale least square problem is implemented by Conjugate Gradient (CG technique, respectively. The proposed method is verified by FPGA (Xilinx Virtex-7 XC7VX690T realization, revealing its effectiveness in real-time applications.

  10. A lower dimensional feature vector for identification of partial discharges of different origin using time measurements

    International Nuclear Information System (INIS)

    Evagorou, Demetres; Kyprianou, Andreas; Georghiou, George E; Lewin, Paul L; Stavrou, Andreas

    2012-01-01

    Partial discharge (PD) classification into sources of different origin is essential in evaluating the severity of the damage caused by its activity on the insulation of power cables and their accessories. More specifically, some types of PD can be classified as having a detrimental effect on the integrity of the insulation while others can be deemed relatively harmless, rendering the correct classification of different PD types of vital importance to electrical utilities. In this work, a feature vector was proposed based on higher order statistics on selected nodes of the wavelet packet transform (WPT) coefficients of time domain measurements, which can compactly represent the characteristics of different PD sources. To assess its performance, experimental data acquired under laboratory conditions for four different PD sources encountered in power systems were used. The two learning machine methods, namely the support vector machine and the probabilistic neural network, employed as the classification algorithms, achieved overall classification rates of around 98%. In comparison, the utilization of the scaled, raw WPT coefficients as a feature vector resulted in classification accuracy of around 99%, but with a significantly higher number of dimensions (1304 to 16), validating the PD identification ability of the proposed feature. Dimensionality reduction becomes a key factor in online, real-time data collection and processing of PD measurements, reducing the classification effort and the data-storage requirements. Therefore, the proposed method can constitute a potential tool for such online measurements, after addressing issues related to on-site measurements such as the rejection of interference. (paper)

  11. Extended causal modeling to assess Partial Directed Coherence in multiple time series with significant instantaneous interactions.

    Science.gov (United States)

    Faes, Luca; Nollo, Giandomenico

    2010-11-01

    The Partial Directed Coherence (PDC) and its generalized formulation (gPDC) are popular tools for investigating, in the frequency domain, the concept of Granger causality among multivariate (MV) time series. PDC and gPDC are formalized in terms of the coefficients of an MV autoregressive (MVAR) model which describes only the lagged effects among the time series and forsakes instantaneous effects. However, instantaneous effects are known to affect linear parametric modeling, and are likely to occur in experimental time series. In this study, we investigate the impact on the assessment of frequency domain causality of excluding instantaneous effects from the model underlying PDC evaluation. Moreover, we propose the utilization of an extended MVAR model including both instantaneous and lagged effects. This model is used to assess PDC either in accordance with the definition of Granger causality when considering only lagged effects (iPDC), or with an extended form of causality, when we consider both instantaneous and lagged effects (ePDC). The approach is first evaluated on three theoretical examples of MVAR processes, which show that the presence of instantaneous correlations may produce misleading profiles of PDC and gPDC, while ePDC and iPDC derived from the extended model provide here a correct interpretation of extended and lagged causality. It is then applied to representative examples of cardiorespiratory and EEG MV time series. They suggest that ePDC and iPDC are better interpretable than PDC and gPDC in terms of the known cardiovascular and neural physiologies.

  12. Real-time characterization of partially observed epidemics using surrogate models.

    Energy Technology Data Exchange (ETDEWEB)

    Safta, Cosmin; Ray, Jaideep; Lefantzi, Sophia; Crary, David (Applied Research Associates, Arlington, VA); Sargsyan, Khachik; Cheng, Karen (Applied Research Associates, Arlington, VA)

    2011-09-01

    We present a statistical method, predicated on the use of surrogate models, for the 'real-time' characterization of partially observed epidemics. Observations consist of counts of symptomatic patients, diagnosed with the disease, that may be available in the early epoch of an ongoing outbreak. Characterization, in this context, refers to estimation of epidemiological parameters that can be used to provide short-term forecasts of the ongoing epidemic, as well as to provide gross information on the dynamics of the etiologic agent in the affected population e.g., the time-dependent infection rate. The characterization problem is formulated as a Bayesian inverse problem, and epidemiological parameters are estimated as distributions using a Markov chain Monte Carlo (MCMC) method, thus quantifying the uncertainty in the estimates. In some cases, the inverse problem can be computationally expensive, primarily due to the epidemic simulator used inside the inversion algorithm. We present a method, based on replacing the epidemiological model with computationally inexpensive surrogates, that can reduce the computational time to minutes, without a significant loss of accuracy. The surrogates are created by projecting the output of an epidemiological model on a set of polynomial chaos bases; thereafter, computations involving the surrogate model reduce to evaluations of a polynomial. We find that the epidemic characterizations obtained with the surrogate models is very close to that obtained with the original model. We also find that the number of projections required to construct a surrogate model is O(10)-O(10{sup 2}) less than the number of samples required by the MCMC to construct a stationary posterior distribution; thus, depending upon the epidemiological models in question, it may be possible to omit the offline creation and caching of surrogate models, prior to their use in an inverse problem. The technique is demonstrated on synthetic data as well as

  13. Identification of partial resetting using De as a function of illumination time

    International Nuclear Information System (INIS)

    Bailey, R.M.; Singarayer, J.S.; Ward, S.; Stokes, S.

    2003-01-01

    Modern age samples from various depositional environments were examined for signal resetting. For 19 modern aeolian/beach samples all D e values obtained were e e values were e as a function of illumination (OSL measurement) time (D e (t)) plots were examined for all samples. Based on previous laboratory experiments, increases in D e (t) were expected for partially reset samples, and constant D e (t) for fully reset samples. All aeolian samples, both modern age and additional 'young' samples ( e (t) while all modern, non-zero D e , fluvial/colluvial samples showed increasing D e (t). 'Replacement plots', where a regenerated signal is substituted for the natural, yielded constant (flat) D e (t). These findings support strongly the use of D e (t) as a method of identifying incomplete resetting in fluvial samples. Potential complicating factors, such as illumination (bleaching) spectrum, thermal instability and component composition are discussed and a series of internal checks on the applicability of the D e (t) for each individual aliquot/grain level are outlined

  14. Actor-critic-based optimal tracking for partially unknown nonlinear discrete-time systems.

    Science.gov (United States)

    Kiumarsi, Bahare; Lewis, Frank L

    2015-01-01

    This paper presents a partially model-free adaptive optimal control solution to the deterministic nonlinear discrete-time (DT) tracking control problem in the presence of input constraints. The tracking error dynamics and reference trajectory dynamics are first combined to form an augmented system. Then, a new discounted performance function based on the augmented system is presented for the optimal nonlinear tracking problem. In contrast to the standard solution, which finds the feedforward and feedback terms of the control input separately, the minimization of the proposed discounted performance function gives both feedback and feedforward parts of the control input simultaneously. This enables us to encode the input constraints into the optimization problem using a nonquadratic performance function. The DT tracking Bellman equation and tracking Hamilton-Jacobi-Bellman (HJB) are derived. An actor-critic-based reinforcement learning algorithm is used to learn the solution to the tracking HJB equation online without requiring knowledge of the system drift dynamics. That is, two neural networks (NNs), namely, actor NN and critic NN, are tuned online and simultaneously to generate the optimal bounded control policy. A simulation example is given to show the effectiveness of the proposed method.

  15. Impact of Partial Time Delay on Temporal Dynamics of Watts-Strogatz Small-World Neuronal Networks

    Science.gov (United States)

    Yan, Hao; Sun, Xiaojuan

    2017-06-01

    In this paper, we mainly discuss effects of partial time delay on temporal dynamics of Watts-Strogatz (WS) small-world neuronal networks by controlling two parameters. One is the time delay τ and the other is the probability of partial time delay pdelay. Temporal dynamics of WS small-world neuronal networks are discussed with the aid of temporal coherence and mean firing rate. With the obtained simulation results, it is revealed that for small time delay τ, the probability pdelay could weaken temporal coherence and increase mean firing rate of neuronal networks, which indicates that it could improve neuronal firings of the neuronal networks while destroying firing regularity. For large time delay τ, temporal coherence and mean firing rate do not have great changes with respect to pdelay. Time delay τ always has great influence on both temporal coherence and mean firing rate no matter what is the value of pdelay. Moreover, with the analysis of spike trains and histograms of interspike intervals of neurons inside neuronal networks, it is found that the effects of partial time delays on temporal coherence and mean firing rate could be the result of locking between the period of neuronal firing activities and the value of time delay τ. In brief, partial time delay could have great influence on temporal dynamics of the neuronal networks.

  16. In vivo near real time imaging of oxygen partial pressures in the glass catfish (Kryptopterus bichirris)

    DEFF Research Database (Denmark)

    Steffensen, John Fleng

    2012-01-01

    of the transparent glass catfish (Kryptopterus bichirris), it is possible to measure near realtime oxygen partial pressure in vivo. We used a commercially-available digital single-lens reflex camera mounted with an optical long pass filter (II = 490 nm) and excited the phosphorescent dye in the microspheres inside...... the fish with externally-mounted blue light emitting diodes (lip = 470 nm) to image the oxygen partial pressure. This method makes it possible to investigate oxygen partial pressures in the vascular system and different tissues of fish without having to insert any probes into the animal. After injection...

  17. In Vivo Gene Therapy of Hemophilia B: Sustained Partial Correction in Factor IX-Deficient Dogs

    Science.gov (United States)

    Kay, Mark A.; Rothenberg, Steven; Landen, Charles N.; Bellinger, Dwight A.; Leland, Frances; Toman, Carol; Finegold, Milton; Thompson, Arthur R.; Read, M. S.; Brinkhous, Kenneth M.; Woo, Savio L. C.

    1993-10-01

    The liver represents a model organ for gene therapy. A method has been developed for hepatic gene transfer in vivo by the direct infusion of recombinant retroviral vectors into the portal vasculature, which results in the persistent expression of exogenous genes. To determine if these technologies are applicable for the treatment of hemophilia B patients, preclinical efficacy studies were done in a hemophilia B dog model. When the canine factor IX complementary DNA was transduced directly into the hepatocytes of affected dogs in vivo, the animals constitutively expressed low levels of canine factor IX for more than 5 months. Persistent expression of the clotting. factor resulted in reductions of whole blood clotting and partial thromboplastin times of the treated animals. Thus, long-term treatment of hemophilia B patients may be feasible by direct hepatic gene therapy in vivo.

  18. Global Regularity and Time Decay for the 2D Magnetohydrodynamic Equations with Fractional Dissipation and Partial Magnetic Diffusion

    Science.gov (United States)

    Dong, Bo-Qing; Jia, Yan; Li, Jingna; Wu, Jiahong

    2018-05-01

    This paper focuses on a system of the 2D magnetohydrodynamic (MHD) equations with the kinematic dissipation given by the fractional operator (-Δ )^α and the magnetic diffusion by partial Laplacian. We are able to show that this system with any α >0 always possesses a unique global smooth solution when the initial data is sufficiently smooth. In addition, we make a detailed study on the large-time behavior of these smooth solutions and obtain optimal large-time decay rates. Since the magnetic diffusion is only partial here, some classical tools such as the maximal regularity property for the 2D heat operator can no longer be applied. A key observation on the structure of the MHD equations allows us to get around the difficulties due to the lack of full Laplacian magnetic diffusion. The results presented here are the sharpest on the global regularity problem for the 2D MHD equations with only partial magnetic diffusion.

  19. A comparison of the fabrication times of all-ceramic partial crowns: Cerec 3D vs IPS Empress.

    Science.gov (United States)

    Gozdowski, S; Reich, S

    2009-01-01

    Apart from precision, the time factor plays a decisive role in the fabrication of all-ceramic dental restorations. Therefore, the aim of this study was to compare two all-ceramic systems with regard to the time required for the fabrication of partial crowns [MODB]. The null hypothesis tested was that the fabrication times of CAD/CAM generated partial crowns are shorter than the fabrication times of partial crowns manufactured in the laboratory. In sixteen model pairs mounted in the articulator, which corresponded to different clinical situations, tooth 36 was prepared for an all-ceramic partial crown [MODB]. With the Cerec3D method [CHAIR], the fabrication of the restoration was simulated directly on the "phantom patient". The IPS Empress system [LAB] was used forthe indirectfabrication method via an impression of the phantom patient. Both methods were used for each preparation. The adhesive luting procedure was not simulated and, therefore, not measured. The mean processing times [hh:mm:ss] were 00:35:05 (SD +/- 03:27 min) for the Cerec method and 04:17:54 (SD +/- 26:01 min) for the Empress method. The mean time on the phantom patient for process-induced activities was 11:47 minutes (SD +/- 02:08 min) for the Cerec method and 03:58 minutes (SD +/- 02:50 min) for the Empress method. Time expenditure for fabrication is only one aspect in order to assess the suitability of a restoration system. Both methods enable the dentist to provide high quality all ceramic restorations. Although the Empress method showed a time advantage of 65% during the fitting phase and occlusal grinding-in on the phantom patient in comparison to the Cerec method, the time spent during the laboratory phase has to be considered as well.

  20. On a higher order multi-term time-fractional partial differential equation involving Caputo-Fabrizio derivative

    OpenAIRE

    Pirnapasov, Sardor; Karimov, Erkinjon

    2017-01-01

    In the present work we discuss higher order multi-term partial differential equation (PDE) with the Caputo-Fabrizio fractional derivative in time. We investigate a boundary value problem for fractional heat equation involving higher order Caputo-Fabrizio derivatives in time-variable. Using method of separation of variables and integration by parts, we reduce fractional order PDE to the integer order. We represent explicit solution of formulated problem in particular case by Fourier series.

  1. An Accurate Approximate-Analytical Technique for Solving Time-Fractional Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    M. Bishehniasar

    2017-01-01

    Full Text Available The demand of many scientific areas for the usage of fractional partial differential equations (FPDEs to explain their real-world systems has been broadly identified. The solutions may portray dynamical behaviors of various particles such as chemicals and cells. The desire of obtaining approximate solutions to treat these equations aims to overcome the mathematical complexity of modeling the relevant phenomena in nature. This research proposes a promising approximate-analytical scheme that is an accurate technique for solving a variety of noninteger partial differential equations (PDEs. The proposed strategy is based on approximating the derivative of fractional-order and reducing the problem to the corresponding partial differential equation (PDE. Afterwards, the approximating PDE is solved by using a separation-variables technique. The method can be simply applied to nonhomogeneous problems and is proficient to diminish the span of computational cost as well as achieving an approximate-analytical solution that is in excellent concurrence with the exact solution of the original problem. In addition and to demonstrate the efficiency of the method, it compares with two finite difference methods including a nonstandard finite difference (NSFD method and standard finite difference (SFD technique, which are popular in the literature for solving engineering problems.

  2. Equivalent construction of the infinitesimal time translation operator in algebraic dynamics algorithm for partial differential evolution equation

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    We give an equivalent construction of the infinitesimal time translation operator for partial differential evolution equation in the algebraic dynamics algorithm proposed by Shun-Jin Wang and his students. Our construction involves only simple partial differentials and avoids the derivative terms of δ function which appear in the course of computation by means of Wang-Zhang operator. We prove Wang’s equivalent theorem which says that our construction and Wang-Zhang’s are equivalent. We use our construction to deal with several typical equations such as nonlinear advection equation, Burgers equation, nonlinear Schrodinger equation, KdV equation and sine-Gordon equation, and obtain at least second order approximate solutions to them. These equations include the cases of real and complex field variables and the cases of the first and the second order time derivatives.

  3. Stochastic partial differential fluid equations as a diffusive limit of deterministic Lagrangian multi-time dynamics.

    Science.gov (United States)

    Cotter, C J; Gottwald, G A; Holm, D D

    2017-09-01

    In Holm (Holm 2015 Proc. R. Soc. A 471 , 20140963. (doi:10.1098/rspa.2014.0963)), stochastic fluid equations were derived by employing a variational principle with an assumed stochastic Lagrangian particle dynamics. Here we show that the same stochastic Lagrangian dynamics naturally arises in a multi-scale decomposition of the deterministic Lagrangian flow map into a slow large-scale mean and a rapidly fluctuating small-scale map. We employ homogenization theory to derive effective slow stochastic particle dynamics for the resolved mean part, thereby obtaining stochastic fluid partial equations in the Eulerian formulation. To justify the application of rigorous homogenization theory, we assume mildly chaotic fast small-scale dynamics, as well as a centring condition. The latter requires that the mean of the fluctuating deviations is small, when pulled back to the mean flow.

  4. Isostable reduction with applications to time-dependent partial differential equations.

    Science.gov (United States)

    Wilson, Dan; Moehlis, Jeff

    2016-07-01

    Isostables and isostable reduction, analogous to isochrons and phase reduction for oscillatory systems, are useful in the study of nonlinear equations which asymptotically approach a stationary solution. In this work, we present a general method for isostable reduction of partial differential equations, with the potential power to reduce the dimensionality of a nonlinear system from infinity to 1. We illustrate the utility of this reduction by applying it to two different models with biological relevance. In the first example, isostable reduction of the Fokker-Planck equation provides the necessary framework to design a simple control strategy to desynchronize a population of pathologically synchronized oscillatory neurons, as might be relevant to Parkinson's disease. Another example analyzes a nonlinear reaction-diffusion equation with relevance to action potential propagation in a cardiac system.

  5. Prediction-based control for LTI systems with uncertain time-varying delays and partial state knowledge

    Science.gov (United States)

    Léchappé, V.; Moulay, E.; Plestan, F.

    2018-06-01

    The stability of a prediction-based controller for linear time-invariant (LTI) systems is studied in the presence of time-varying input and output delays. The uncertain delay case is treated as well as the partial state knowledge case. The reduction method is used in order to prove the convergence of the closed-loop system including the state observer, the predictor and the plant. Explicit conditions that guarantee the closed-loop stability are given, thanks to a Lyapunov-Razumikhin analysis. Simulations illustrate the theoretical results.

  6. A Simple Differential Modulation Scheme for Quasi-Orthogonal Space-Time Block Codes with Partial Transmit Diversity

    Directory of Open Access Journals (Sweden)

    Lingyang Song

    2007-04-01

    Full Text Available We report a simple differential modulation scheme for quasi-orthogonal space-time block codes. A new class of quasi-orthogonal coding structures that can provide partial transmit diversity is presented for various numbers of transmit antennas. Differential encoding and decoding can be simplified for differential Alamouti-like codes by grouping the signals in the transmitted matrix and decoupling the detection of data symbols, respectively. The new scheme can achieve constant amplitude of transmitted signals, and avoid signal constellation expansion; in addition it has a linear signal detector with very low complexity. Simulation results show that these partial-diversity codes can provide very useful results at low SNR for current communication systems. Extension to more than four transmit antennas is also considered.

  7. The Influence of Injection Timing on Performance Characteristics of Diesel Engine Using Jatropha Biodiesel with and without Partial Hydrogenation

    Directory of Open Access Journals (Sweden)

    Rizqon Fajar

    2014-07-01

    Full Text Available Experimental research has been conducted to investigate the effects of blend of hydrogenated and unhydrogenated Jatropha biodiesel with diesel fuel in volume ratio of 30:70 (B30 on combustion characteristics (BSFC, thermal efficiency and smoke emission of single cylinder diesel engine. In this experiment, engine speed was kept constant at 1,500, 2,500, and 3,500 rpm with maximum engine load at BMEP 5 bar and injection timings were varied. Experimental result showed that at engine speed 1,500 rpm, BSFC of B30 hydrogenated and unhydrogenated Jatropha biodiesel were higher than it of diesel fuel at all injection timings (10° to 18° BTDC. At the same condition, partial hydrogenated Jatropha biodiesel showed higher BSFC than unhydrogenated Jatropha biodiesel. However, the difference in BSFC became smaller for all fuels at engine speed 2,500 rpm and 3,500 rpm at all injection timing. Jatropha biodiesel with and without partial hydrogenation tend to have higher thermal efficiency compared with diesel fuel at all engine speed and injection timing. The best injection timings to operate B30 Jatropha biodiesel with and without hydrogenation were 14°, 18° and 24° BTDC at engine speed 1,500, 2,500, and 3,500 rpm respectively. This conclusion was deduced based on the minimum value of BSFC and the maximum value of thermal efficiency. Smoke emissions for all fuels were in the same level for all conditions.

  8. INERTIAL MANIFOLDS FOR NONAUTONOMOUS SEMILINEAR PARABOLIC PARTIAL DIFFERENTIAL EQUATIONS WITH TIME DELAYS

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The present paper deals with the long-time behavior of a class of nonautonomous retarded semilinear parabolic differential equations. When the time delays are small enough and the spectral gap conditions hold, the inertial manifolds of the nonautonomous retard parabolic equations are constructed by using the Lyapunov-Perron method.

  9. Fast Time and Space Parallel Algorithms for Solution of Parabolic Partial Differential Equations

    Science.gov (United States)

    Fijany, Amir

    1993-01-01

    In this paper, fast time- and Space -Parallel agorithms for solution of linear parabolic PDEs are developed. It is shown that the seemingly strictly serial iterations of the time-stepping procedure for solution of the problem can be completed decoupled.

  10. The large discretization step method for time-dependent partial differential equations

    Science.gov (United States)

    Haras, Zigo; Taasan, Shlomo

    1995-01-01

    A new method for the acceleration of linear and nonlinear time dependent calculations is presented. It is based on the Large Discretization Step (LDS) approximation, defined in this work, which employs an extended system of low accuracy schemes to approximate a high accuracy discrete approximation to a time dependent differential operator. Error bounds on such approximations are derived. These approximations are efficiently implemented in the LDS methods for linear and nonlinear hyperbolic equations, presented here. In these algorithms the high and low accuracy schemes are interpreted as the same discretization of a time dependent operator on fine and coarse grids, respectively. Thus, a system of correction terms and corresponding equations are derived and solved on the coarse grid to yield the fine grid accuracy. These terms are initialized by visiting the fine grid once in many coarse grid time steps. The resulting methods are very general, simple to implement and may be used to accelerate many existing time marching schemes.

  11. Real-Time Monitoring of Singlet Oxygen and Oxygen Partial Pressure During the Deep Photodynamic Therapy In Vitro.

    Science.gov (United States)

    Li, Weitao; Huang, Dong; Zhang, Yan; Liu, Yangyang; Gu, Yueqing; Qian, Zhiyu

    2016-09-01

    Photodynamic therapy (PDT) is an effective noninvasive method for the tumor treatment. The major challenge in current PDT research is how to quantitatively evaluate therapy effects. To our best knowledge, this is the first time to combine multi-parameter detection methods in PDT. More specifically, we have developed a set of system, including the high-sensitivity measurement of singlet oxygen, oxygen partial pressure and fluorescence image. In this paper, the detection ability of the system was validated by the different concentrations of carbon quantum dots. Moreover, the correlation between singlet oxygen and oxygen partial pressure with laser irradiation was observed. Then, the system could detect the signal up to 0.5 cm tissue depth with 660 nm irradiation and 1 cm tissue depth with 980 nm irradiation by using up-conversion nanoparticles during PDT in vitro. Furthermore, we obtained the relationship among concentration of singlet oxygen, oxygen partial pressure and tumor cell viability under certain conditions. The results indicate that the multi-parameter detection system is a promising asset to evaluate the deep tumor therapy during PDT. Moreover, the system might be potentially used for the further study in biology and molecular imaging.

  12. The adaptive CCCG({eta}) method for efficient solution of time dependent partial differential equations

    Energy Technology Data Exchange (ETDEWEB)

    Campos, F.F. [Universidade Federal de Minas Gerais, Belo Horizonte (Brazil); Birkett, N.R.C. [Oxford Univ. Computing Lab. (United Kingdom)

    1996-12-31

    The Controlled Cholesky factorisation has been shown to be a robust preconditioner for the Conjugate Gradient method. In this scheme the amount of fill-in is defined in terms of a parameter {eta}, the number of extra elements allowed per column. It is demonstrated how an optimum value of {eta} can be automatically determined when solving time dependent p.d.e.`s using an implicit time step method. A comparison between CCCG({eta}) and the standard ICCG solving parabolic problems on general grids shows CCCG({eta}) to be an efficient general purpose solver.

  13. Real time flaw detection and characterization in tube through partial least squares and SVR: Application to eddy current testing

    Science.gov (United States)

    Ahmed, Shamim; Miorelli, Roberto; Calmon, Pierre; Anselmi, Nicola; Salucci, Marco

    2018-04-01

    This paper describes Learning-By-Examples (LBE) technique for performing quasi real time flaw localization and characterization within a conductive tube based on Eddy Current Testing (ECT) signals. Within the framework of LBE, the combination of full-factorial (i.e., GRID) sampling and Partial Least Squares (PLS) feature extraction (i.e., GRID-PLS) techniques are applied for generating a suitable training set in offine phase. Support Vector Regression (SVR) is utilized for model development and inversion during offine and online phases, respectively. The performance and robustness of the proposed GIRD-PLS/SVR strategy on noisy test set is evaluated and compared with standard GRID/SVR approach.

  14. A Sequential, Implicit, Wavelet-Based Solver for Multi-Scale Time-Dependent Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    Donald A. McLaren

    2013-04-01

    Full Text Available This paper describes and tests a wavelet-based implicit numerical method for solving partial differential equations. Intended for problems with localized small-scale interactions, the method exploits the form of the wavelet decomposition to divide the implicit system created by the time-discretization into multiple smaller systems that can be solved sequentially. Included is a test on a basic non-linear problem, with both the results of the test, and the time required to calculate them, compared with control results based on a single system with fine resolution. The method is then tested on a non-trivial problem, its computational time and accuracy checked against control results. In both tests, it was found that the method requires less computational expense than the control. Furthermore, the method showed convergence towards the fine resolution control results.

  15. Expectation-maximization algorithms for learning a finite mixture of univariate survival time distributions from partially specified class values

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youngrok [Iowa State Univ., Ames, IA (United States)

    2013-05-15

    Heterogeneity exists on a data set when samples from di erent classes are merged into the data set. Finite mixture models can be used to represent a survival time distribution on heterogeneous patient group by the proportions of each class and by the survival time distribution within each class as well. The heterogeneous data set cannot be explicitly decomposed to homogeneous subgroups unless all the samples are precisely labeled by their origin classes; such impossibility of decomposition is a barrier to overcome for estimating nite mixture models. The expectation-maximization (EM) algorithm has been used to obtain maximum likelihood estimates of nite mixture models by soft-decomposition of heterogeneous samples without labels for a subset or the entire set of data. In medical surveillance databases we can find partially labeled data, that is, while not completely unlabeled there is only imprecise information about class values. In this study we propose new EM algorithms that take advantages of using such partial labels, and thus incorporate more information than traditional EM algorithms. We particularly propose four variants of the EM algorithm named EM-OCML, EM-PCML, EM-HCML and EM-CPCML, each of which assumes a specific mechanism of missing class values. We conducted a simulation study on exponential survival trees with five classes and showed that the advantages of incorporating substantial amount of partially labeled data can be highly signi cant. We also showed model selection based on AIC values fairly works to select the best proposed algorithm on each specific data set. A case study on a real-world data set of gastric cancer provided by Surveillance, Epidemiology and End Results (SEER) program showed a superiority of EM-CPCML to not only the other proposed EM algorithms but also conventional supervised, unsupervised and semi-supervised learning algorithms.

  16. Effect of percolation rate on water-travel time in deep, partially saturated zones

    International Nuclear Information System (INIS)

    Peters, R.R.; Gauthier, J.H.; Dudley, A.L.

    1986-02-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) project is investigating Yucca Mountain, Nye county, Nevada, as a prospective site for a radioactive-waste repository. The Yucca Mountain site is unique among those currently being investigated by the US Department of Energy (DOE) in that the prospective repository location is in the unsaturated zone, approximately 300 m above the water table. The rock units at Yucca Mountain can be grouped into three types: (1) vitric tuffs with high matrix conductivity and few fractures; (2) zeolitized tuffs with low matrix conductivity and few fractures; and (3) densely welded tuffs with low matrix conductivities and many fractures. The prospective repository zone is in densely welded tuff; the units between it and the water table are of types 1 and 2. Current percolation rates through Yucca Mountain, and those that are currently postulated under future climatic conditions, are thought to be of the order of the saturated matrix conductivity of some of the units. Although it is probable that there is now little or no water movement in fracture, it is necessary to investigate the potential for fracture flow, especially that which could be initiated under future climatic conditions. Significant fracture flow, if present, could reduce the water travel time between the repository and the water table. A composite-porosity, continuum model was developed to model flow in a fractured, porous medium. Simulations using data from the Yucca Mountain site and this model in the one-dimensional code TOSPAC indicate that current estimates of the percolation rate result in water movement confined to the matrix and that the water-travel time from the repository to the water table is on the order of hundreds of thousands of years. this result is sensitive to the percolation rate; an increase in percolation rate of a factor of 10 many initiate water movement in the fractures, reducing the travel time significantly

  17. Partial Fourier analysis of time-harmonic Maxwell's equations in axisymmetric domains

    International Nuclear Information System (INIS)

    Nkemzi, Boniface

    2003-01-01

    We analyze the Fourier method for treating time-harmonic Maxwell's equations in three-dimensional axisymmetric domains with non-axisymmetric data. The Fourier method reduces the three-dimensional boundary value problem to a system of decoupled two-dimensional boundary value problems on the plane meridian domain of the axisymmetric domain. The reduction process is fully described and suitable weighted spaces are introduced on the meridian domain to characterize the two-dimensional solutions. In particular, existence and uniqueness of solutions of the two-dimensional problems is proved and a priori estimates for the solutions are given. (author)

  18. Effect of percolation rate on water-travel time in deep, partially saturated zones

    International Nuclear Information System (INIS)

    Peters, R.R.; Gauthier, J.H.; Dudley, A.L.

    1986-01-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) project is investigating Yucca Mountain, Nye County, Nevada, as a prospective site for a radioactive-waste repository. The Yucca Mountain site is unique among those currently being investigated by the US Department of Energy (DOE) in that the prospective repository location is in the unsaturated zone, approximately 300 m above the water table. A composite-porosity, continuum model was developed to model flow in a fractured, porous medium. Simulations using data from the Yucca Mountain site and this model in the one-dimensional code TOSPAC indicate that current estimates of the percolation rate result in water movement confined to the matrix and that the water-travel time from the repository to the water table in on the order of hundreds of thousands of years. This result is sensitive to the percolation rate; an increase in percolation rate of a factor of 10 may initiate water movement in the fractures, reducing the travel time significantly

  19. Inventory Model for Non – Instantaneous Deteriorating Items, Stock Dependent Demand, Partial Backlogging, and Inflation over a Finite Time Horizon

    Directory of Open Access Journals (Sweden)

    Neeraj Kumar

    2016-05-01

    Full Text Available In the present study, the Economic Order Quantity (EOQ model of two-warehouse deals with non-instantaneous deteriorating items, the demand rate considered as stock dependent and model affected by inflation under the pattern of time value of money over a finite planning horizon. Shortages are allowed and partially backordered depending on the waiting time for the next replenishment. The main objective of this work is to minimize the total inventory cost and finding the optimal interval and the optimal order quantity. An algorithm is designed to find the optimum solution of the proposed model. Numerical examples are given to demonstrate the results. Also, the effect of changes in the different parameters on the optimal total cost is graphically presented.

  20. Arabidopsis SUMO protease ASP1 positively regulates flowering time partially through regulating FLC stability 

    KAUST Repository

    Kong, Xiangxiong; Luo, Xi; Qu, Gao Ping; Liu, Peng; Jin, Jing Bo

    2016-01-01

    The initiation of flowering is tightly regulated by the endogenous and environment signals, which is crucial for the reproductive success of flowering plants. It is well known that autonomous and vernalization pathways repress transcription of FLOWERING LOCUS C (FLC), a focal floral repressor, but how its protein stability is regulated remains largely unknown. Here, we found that mutations in a novel Arabidopsis SUMO protease 1 (ASP1) resulted in a strong late-flowering phenotype under long-days, but to a lesser extent under short-days. ASP1 localizes in the nucleus and exhibited a SUMO protease activity in vitro and in vivo. The conserved Cys-577 in ASP1 is critical for its enzymatic activity, as well as its physiological function in the regulation of flowering time. Genetic and gene expression analyses demonstrated that ASP1 promotes transcription of positive regulators of flowering, such as FT, SOC1 and FD, and may function in both CO-dependent photoperiod pathway and FLC-dependent pathways. Although the transcription level of FLC was not affected in the loss-of-function asp1 mutant, the protein stability of FLC was increased in the asp1 mutant. Taken together, this study identified a novel bona fide SUMO protease, ASP1, which positively regulates transition to flowering at least partly by repressing FLC protein stability.

  1. Dynamic Analysis of Partially Embedded Structures Considering Soil-Structure Interaction in Time Domain

    Directory of Open Access Journals (Sweden)

    Sanaz Mahmoudpour

    2011-01-01

    Full Text Available Analysis and design of structures subjected to arbitrary dynamic loadings especially earthquakes have been studied during past decades. In practice, the effects of soil-structure interaction on the dynamic response of structures are usually neglected. In this study, the effect of soil-structure interaction on the dynamic response of structures has been examined. The substructure method using dynamic stiffness of soil is used to analyze soil-structure system. A coupled model based on finite element method and scaled boundary finite element method is applied. Finite element method is used to analyze the structure, and scaled boundary finite element method is applied in the analysis of unbounded soil region. Due to analytical solution in the radial direction, the radiation condition is satisfied exactly. The material behavior of soil and structure is assumed to be linear. The soil region is considered as a homogeneous half-space. The analysis is performed in time domain. A computer program is prepared to analyze the soil-structure system. Comparing the results with those in literature shows the exactness and competency of the proposed method.

  2. Arabidopsis SUMO protease ASP1 positively regulates flowering time partially through regulating FLC stability 

    KAUST Repository

    Kong, Xiangxiong

    2016-12-07

    The initiation of flowering is tightly regulated by the endogenous and environment signals, which is crucial for the reproductive success of flowering plants. It is well known that autonomous and vernalization pathways repress transcription of FLOWERING LOCUS C (FLC), a focal floral repressor, but how its protein stability is regulated remains largely unknown. Here, we found that mutations in a novel Arabidopsis SUMO protease 1 (ASP1) resulted in a strong late-flowering phenotype under long-days, but to a lesser extent under short-days. ASP1 localizes in the nucleus and exhibited a SUMO protease activity in vitro and in vivo. The conserved Cys-577 in ASP1 is critical for its enzymatic activity, as well as its physiological function in the regulation of flowering time. Genetic and gene expression analyses demonstrated that ASP1 promotes transcription of positive regulators of flowering, such as FT, SOC1 and FD, and may function in both CO-dependent photoperiod pathway and FLC-dependent pathways. Although the transcription level of FLC was not affected in the loss-of-function asp1 mutant, the protein stability of FLC was increased in the asp1 mutant. Taken together, this study identified a novel bona fide SUMO protease, ASP1, which positively regulates transition to flowering at least partly by repressing FLC protein stability.

  3. Effects of inflation and time value of money on an inventory system with deteriorating items and partially backlogged shortages

    Directory of Open Access Journals (Sweden)

    Chandra K. Jaggi

    2016-04-01

    Full Text Available As the long arm of the grinding, deep financial crisis continues to haunt the global economy, the effects of inflation and time value of money cannot be oblivious to an inventory system. Inflation, defined as a general rise in the prices of goods and services over a period of time, has monetary depreciation as one of its major side effects. And, since inventories correspond to substantial investment in capital for any organization, it would be unethical if the effects of inflation and time value of money are not considered while determining the optimal inventory policy. Moreover, deterioration of items is a phenomenon which cannot be ignored, as it may yield misleading results. Further, under the inflationary conditions, the different cost parameters including the price are bound to vary from cycle to cycle over the planning horizon. Another important factor is shortages which no retailer would prefer, and in practice are partially backlogged and partially lost. In order to convert the lost sales into sales, the retailer offers such customers an incentive, by charging them the price prevailing at the time of placing an order, instead of the current inflated price. Therefore, bearing in mind these facts, the present paper develops an inventory model for a retailer dealing with deteriorating items under inflationary conditions over a fixed planning horizon. The objective is to derive the optimal number of cycles and cycle length that maximizes the net present value of the total profit over a fixed planning horizon. An appropriate algorithm has been proposed to obtain the optimal solution. Finally, a numerical example is provided to illustrate the proposed model. Sensitivity analysis of the optimal solution with respect to major parameters is carried out and some managerial inferences have been presented.

  4. An EOQ model of time quadratic and inventory dependent demand for deteriorated items with partially backlogged shortages under trade credit

    Science.gov (United States)

    Singh, Pushpinder; Mishra, Nitin Kumar; Singh, Vikramjeet; Saxena, Seema

    2017-07-01

    In this paper a single buyer, single supplier inventory model with time quadratic and stock dependent demand for a finite planning horizon has been studied. Single deteriorating item which suffers shortage, with partial backlogging and some lost sales is considered. Model is divided into two scenarios, one with non permissible delay in payment and other with permissible delay in payment. Latter is called, centralized system, where supplier offers trade credit to retailer. In the centralized system cost saving is shared amongst the two. The objective is to study the difference in minimum costs borne by retailer and supplier, under two scenarios including the above mentioned parameters. To obtain optimal solution of the problem the model is solved analytically. Numerical example and a comparative study are then discussed supported by sensitivity analysis of each parameter.

  5. A weighted multiple-relaxation-time lattice Boltzmann method for multiphase flows and its application to partial coalescence cascades

    Science.gov (United States)

    Fakhari, Abbas; Bolster, Diogo; Luo, Li-Shi

    2017-07-01

    We present a lattice Boltzmann method (LBM) with a weighted multiple-relaxation-time (WMRT) collision model and an adaptive mesh refinement (AMR) algorithm for direct numerical simulation of two-phase flows in three dimensions. The proposed WMRT model enhances the numerical stability of the LBM for immiscible fluids at high density ratios, particularly on the D3Q27 lattice. The effectiveness and efficiency of the proposed WMRT-LBM-AMR is validated through simulations of (a) buoyancy-driven motion and deformation of a gas bubble rising in a viscous liquid; (b) the bag-breakup mechanism of a falling drop; (c) crown splashing of a droplet on a wet surface; and (d) the partial coalescence mechanism of a liquid drop at a liquid-liquid interface. The numerical simulations agree well with available experimental data and theoretical approximations where applicable.

  6. On the effects of fuel properties and injection timing in partially premixed compression ignition of low octane fuels

    KAUST Repository

    Naser, Nimal

    2017-06-29

    A better understanding on the effects of fuel properties and injection timing is required to improve the performance of advanced engines based on low temperature combustion concepts. In this work, an experimental and computational study was conducted to investigate the effects of physical and chemical kinetic properties of low octane fuels and their surrogates in partially premixed compression ignition (PPCI) engines. The main objective was to identify the relative importance of physical versus chemical kinetic properties in predicting practical fuel combustion behavior across a range of injection timings. Two fuel/surrogate pairs were chosen for comparison: light naphtha (LN) versus the primary reference fuel (PRF) with research octane number of 65 (PRF 65), and FACE (fuels for advanced combustion engines) I gasoline versus PRF 70. Two sets of parametric studies were conducted: the first varied the amount of injected fuel mass at different injection timings to match a fixed combustion phasing, and the second maintained the same injected fuel mass at each injection timing to assess resulting combustion phasing changes. Full-cycle computational fluid dynamic engine simulations were conducted by accounting for differences in the physical properties of the original and surrogate fuels, while employing identical chemical kinetics. The simulations were found to capture trends observed in the experiments, while providing details on spatial mixing and chemical reactivity for different fuels and injection timings. It was found that differences in physical properties become increasingly important as injection timing was progressively delayed from premixed conditions, and this was rationalized by analysis of mixture stratification patterns resulting from injection of fuels with different physical properties. The results suggest that accurate descriptions of both physical and chemical behavior of fuels are critical in predictive simulations of PPCI engines for a wide range of

  7. On the effects of fuel properties and injection timing in partially premixed compression ignition of low octane fuels

    KAUST Repository

    Naser, Nimal; Jaasim, Mohammed; Atef, Nour; Chung, Suk-Ho; Im, Hong G.; Sarathy, Mani

    2017-01-01

    A better understanding on the effects of fuel properties and injection timing is required to improve the performance of advanced engines based on low temperature combustion concepts. In this work, an experimental and computational study was conducted to investigate the effects of physical and chemical kinetic properties of low octane fuels and their surrogates in partially premixed compression ignition (PPCI) engines. The main objective was to identify the relative importance of physical versus chemical kinetic properties in predicting practical fuel combustion behavior across a range of injection timings. Two fuel/surrogate pairs were chosen for comparison: light naphtha (LN) versus the primary reference fuel (PRF) with research octane number of 65 (PRF 65), and FACE (fuels for advanced combustion engines) I gasoline versus PRF 70. Two sets of parametric studies were conducted: the first varied the amount of injected fuel mass at different injection timings to match a fixed combustion phasing, and the second maintained the same injected fuel mass at each injection timing to assess resulting combustion phasing changes. Full-cycle computational fluid dynamic engine simulations were conducted by accounting for differences in the physical properties of the original and surrogate fuels, while employing identical chemical kinetics. The simulations were found to capture trends observed in the experiments, while providing details on spatial mixing and chemical reactivity for different fuels and injection timings. It was found that differences in physical properties become increasingly important as injection timing was progressively delayed from premixed conditions, and this was rationalized by analysis of mixture stratification patterns resulting from injection of fuels with different physical properties. The results suggest that accurate descriptions of both physical and chemical behavior of fuels are critical in predictive simulations of PPCI engines for a wide range of

  8. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures

    Science.gov (United States)

    Viswambaran, M.; Sundaram, R. K.

    2015-01-01

    Statement of Problem: Inaccuracies in the fit of palatal major connectors may be related to distortion of the wax pattern due to prolonged storage time and faulty major connector design. Purpose: This in vitro study was carried out to find out the effect of storage time and major connector design on the accuracy of cobalt-chromium cast removable partial dentures (RPDs). Materials and Methods: A brass metal die with a Kennedy Class III, modification 1, the partially edentulous arch was used as a master die. Thirty-six refractory casts were fabricated from the master die. The refractory casts were divided into three groups (Group I: Anterior-posterior palatal bar, Group II: Palatal strap and Group III: Palatal plate) based on the design of maxillary major connector and subdivided into four groups (sub Group A: 01 h, sub Group B: 03 h, Sub Group C: 06 h, and sub Group D: 24 h) based on the storage time. For each group, 12 frameworks were fabricated. The influence of wax pattern storage time and the accuracy of the fit palatal major connector designs on the master die were compared. Casting defects (nodules/incompleteness) of the frameworks were also evaluated before finishing and polishing. Repeated measures analysis of variance was used to analyze the data. Results: The gap discrepancy was least in sub Group A (01 h) followed by sub Group B (03 h) and C (06 h) and most in sub Group D (24 h). Statistically significant differences (P < 0.05 in all locations L1–L5) in the fit of the framework were related to the design of the major connector. The gap discrepancy was least in Group I (anterior-posterior palatal bar) followed by Group II (palatal strap) and most in Group II (palatal plate). Conclusions: It is recommended that the wax patterns for RPD to be invested immediately on completion of the wax procedure. The selection of a major connector design is crucial for an accurate fit of RPD. PMID:26681850

  9. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures

    Directory of Open Access Journals (Sweden)

    M Viswambaran

    2015-01-01

    Full Text Available Statement of Problem: Inaccuracies in the fit of palatal major connectors may be related to distortion of the wax pattern due to prolonged storage time and faulty major connector design. Purpose: This in vitro study was carried out to find out the effect of storage time and major connector design on the accuracy of cobalt-chromium cast removable partial dentures (RPDs. Materials and Methods: A brass metal die with a Kennedy Class III, modification 1, the partially edentulous arch was used as a master die. Thirty-six refractory casts were fabricated from the master die. The refractory casts were divided into three groups (Group I: Anterior-posterior palatal bar, Group II: Palatal strap and Group III: Palatal plate based on the design of maxillary major connector and subdivided into four groups (sub Group A: 01 h, sub Group B: 03 h, Sub Group C: 06 h, and sub Group D: 24 h based on the storage time. For each group, 12 frameworks were fabricated. The influence of wax pattern storage time and the accuracy of the fit palatal major connector designs on the master die were compared. Casting defects (nodules/incompleteness of the frameworks were also evaluated before finishing and polishing. Repeated measures analysis of variance was used to analyze the data. Results: The gap discrepancy was least in sub Group A (01 h followed by sub Group B (03 h and C (06 h and most in sub Group D (24 h. Statistically significant differences (P < 0.05 in all locations L1–L5 in the fit of the framework were related to the design of the major connector. The gap discrepancy was least in Group I (anterior-posterior palatal bar followed by Group II (palatal strap and most in Group II (palatal plate. Conclusions: It is recommended that the wax patterns for RPD to be invested immediately on completion of the wax procedure. The selection of a major connector design is crucial for an accurate fit of RPD.

  10. Evaluation of short repetition time, partial flip angle, gradient recalled echo pulse sequences in cervical spine imaging

    International Nuclear Information System (INIS)

    Enzmann, D.; Rubin, J.B.

    1987-01-01

    A short repetition time (TR), partial flip angle, gradient recalled echo pulse sequence (GRASS) was prospectively studied to optimize it for the diagnosis of cervical disk and cord disease in 98 patients. Changes in signal-to-noise ratio (SNR) and contrast were measured as the following parameters were varied: flip angle (3 0 to 18 0 ), TR (22-60 msec), and echo time (TE) (12.5-25 msec). Flip angle was the single most important parameter. For disk disease, cerebrospinal fluid (CSF) SNR peaked at an 8 0 flip angle in the axial view but at a 4 0 flip angle in the sagittal view. In the sagittal view, disk-CSF contrast decreased progressively from a flip angle of 3 0 , while in the axial view it peaked at 10 0 . For cord lesions the findings were similar except that lesion-cord contrast could be increased by lengthening both TR and TE. No one combination of parameters proved greatly superior for either disk disease or cord disease. The selection of parameters required balancing of several factors that often had opposing effects

  11. Measurement of the Time-Dependent CP Asymmetry of Partially Reconstructed B0 to D*+D*- Decays

    Energy Technology Data Exchange (ETDEWEB)

    Lees, J. P.

    2012-08-13

    We present a new measurement of the time-dependent CP asymmetry of B{sup 0} {yields}D*{sup +}D*{sup -} decays using (471 {+-} 5) million B{bar B} pairs collected with the BABAR detector at the PEP-II B Factory at the SLAC National Accelerator Laboratory. Using the technique of partial reconstruction, we measure the time-dependent CP asymmetry parameters S = -0.34 {+-} 0.12 {+-} 0.05 and C = +0:15 {+-} 0.09 {+-} 0.04. Using the value for the CP-odd fraction R{perpendicular} = 0.158 {+-} 0.028 {+-} 0.006, previously measured by BABAR with fully reconstructed B{sup 0} {yields} D{sup *+}D{sup *-} events, we extract the CP-even components S{sub +} = -0.49 {+-} 0.18 {+-} 0.07 {+-} 0.04 and C{sub +} = +0.15 {+-} 0.09 {+-} 0.04. In each case, the first uncertainty is statistical and the second is systematic; the third uncertainty on S{sub +} is the contribution from the uncertainty on R{perpendicular}. The measured value of the CP-even component S{sub +} is consistent with the value of sin 2{beta} measured in b {yields} (c{bar c})s transitions, and with the Standard Model expectation of small penguin contributions.

  12. Effects of Injection Timing on Fluid Flow Characteristics of Partially Premixed Combustion Based on High-Speed Particle Image Velocimetry

    KAUST Repository

    Izadi Najafabadi, Mohammad

    2017-03-28

    Partially Premixed Combustion (PPC) is a promising combustion concept ,based on judicious tuning of the charge stratification, to meet the increasing demands of emission legislation and to improve fuel efficiency. Longer ignition delays of PPC in comparison with conventional diesel combustion provide better fuel/air mixture which decreases soot and NO emissions. Moreover, a proper injection timing and strategy for PPC can improve the combustion stability as a result of a higher level of fuel stratification in comparison with the Homogeneous Charge Compression Ignition (HCCI) concept. Injection timing is the major parameter with which to affect the level of fuel and combustion stratification and to control the combustion phasing and the heat release behavior. The scope of the present study is to investigate the fluid flow characteristics of PPC at different injection timings. To this end, high-speed Particle Image Velocimetry (PIV) is implemented in a light-duty optical engine to measure fluid flow characteristics, including the flow fields, mean velocity and cycle-resolved turbulence, inside the piston bowl as well as the squish region with a temporal resolution of 1 crank angle degree at 800 rpm. Two injectors, having 5 and 7 holes, were compared to see their effects on fluid flow and heat release behavior for different injection timings. Reactive and non-reactive measurements were performed to distinguish injection-driven and combustion-driven turbulence. Formation of vortices and higher turbulence levels enhance the air/fuel interaction, changing the level of fuel stratification and combustion duration. Results demonstrate clearly how turbulence level correlates with heat release behavior, and provide a quantitative dataset for validation of numerical simulations.

  13. γ-ray induced chromosome aberration in rabbit peripheral blood lymphocytes irradiated in partial and whole body and decline of aberration rate with time post-exposure

    International Nuclear Information System (INIS)

    Zhang Lianzhen; Deng Zhicheng; Wang Haiyan

    1997-01-01

    Te author presents the results of study on 60 Co γ-ray induced chromosome aberration in rabbits peripheral blood lymphocytes irradiated in partial and whole body and the aberration rate decrease with the time of post-exposure. The experiments included 5 groups, it was whole-body exposure group, partial-body exposure (abdomen and pelvic cavity) group, blood irradiation group in vitro and control group respectively. Radiation dose was 3.0 Gy delivered at rate of 0.5 Gy/min. The results show that it was no significant differences between whole body and in blood irradiation group. The chromosome aberration yield in whole body exposure group was higher than that in partial-body group and in the abdomen exposure group was higher than in that in the pelvic cavity irradiation; The chromosome aberration rate decreased with the time of post-exposure in partial and whole body by γ-ray irradiation

  14. Residual oxygen time model for oxygen partial pressure near 130 kPa (1.3 atm).

    Science.gov (United States)

    Shykoff, Barbara E

    2015-01-01

    A two-part residual oxygen time model predicts the probability of detectible pulmonary oxygen toxicity P(P[O2tox]) after dives with oxygen partial pressure (PO2) approximately 130 kPa, and provides a tool to plan dive series with selected risk of P[O2tox]. Data suggest that pulmonary oxygen injury at this PO2 is additive between dives. Recovery begins after a delay and continues during any following dive. A logistic relation expresses P(P[O2tox]) as a function of dive duration (T(dur)) [hours]: P(P[O2tox]) = 100/[1+exp (3.586-0.49 x T(dur))] This expression maps T(dur) to P(P[O2tox]) or, in the linear mid-portion of the curve, P(P[O2tox]) usefully to T(dur). For multiple dives or during recovery, it maps to an equivalent dive duration, T(eq). T(eq) was found after second dives of duration T(dur 2). Residual time from the first dive t(r) = T(eq) - T(dur2). With known t(r), t and T(dur) a recovery model was fitted. t(r) = T(dur) x exp [-k x((t-5)/T(dur)2], where t = t - 5 hours, k = 0.149 for resting, and 0.047 for exercising divers, and t represents time after surfacing. The fits were assessed for 1,352 man-dives. Standard deviations of the residuals were 8.5% and 18.3% probability for resting or exercise dives, respectively.

  15. Effects of injection timing on fluid flow characteristics of partially premixed combustion based on high-speed particle image velocimetry

    NARCIS (Netherlands)

    Izadi Najafabadi, M.; Tanov, S.; Wang, H.; Somers, L.M.T.; Johansson, B.; Dam, N.J.

    2017-01-01

    Partially premixed combustion (PPC) is a promising combustion concept to meet the increasing demands of emission legislation and to improve fuel efficiency. Longer ignition delay of PPC in comparison with conventional diesel combustion provide better fuel/air mixture which decreases soot and NOx

  16. Spectral and partial-wave decomposition of time-dependent wave functions on a grid: Photoelectron spectra of H and H2+ in electromagnetic fields

    International Nuclear Information System (INIS)

    Nikolopoulos, L. A. A.; Kjeldsen, T. K.; Madsen, L. B.

    2007-01-01

    We present a method for spectral (bound and continuum) and partial-wave analysis of a three-dimensional time-dependent wave function, defined on a grid, without projecting onto the field-free eigenstates of the system. The method consists of propagating the time-dependent Schroedinger equation to obtain its autocorrelation function C(t)= after the end of the interaction, at time T, of the system with an external time-dependent field. The Fourier spectrum of this correlation function is directly related to the expansion coefficients of the wave function on the field-free bound and continuum energy eigenstates of the system. By expanding on a spherical harmonics basis we show how to calculate the contribution of the various partial waves to the total photoelectron energy spectrum

  17. Investigation of hemorheological and analgesic properties of Qing ...

    African Journals Online (AJOL)

    viscosity, plasma viscosity, activated partial thromboplastin time (APTT), thrombin time (TT), ... International Pharmaceutical Abstract, Chemical Abstracts, Embase, Index Copernicus, EBSCO, .... mice were measured using automatic image.

  18. Series expansion solutions for the multi-term time and space fractional partial differential equations in two- and three-dimensions

    Science.gov (United States)

    Ye, H.; Liu, F.; Turner, I.; Anh, V.; Burrage, K.

    2013-09-01

    Fractional partial differential equations with more than one fractional derivative in time describe some important physical phenomena, such as the telegraph equation, the power law wave equation, or the Szabo wave equation. In this paper, we consider two- and three-dimensional multi-term time and space fractional partial differential equations. The multi-term time-fractional derivative is defined in the Caputo sense, whose order belongs to the interval (1,2],(2,3],(3,4] or (0, m], and the space-fractional derivative is referred to as the fractional Laplacian form. We derive series expansion solutions based on a spectral representation of the Laplacian operator on a bounded region. Some applications are given for the two- and three-dimensional telegraph equation, power law wave equation and Szabo wave equation.

  19. A flowing liquid test system for assessing the linearity and time-response of rapid fibre optic oxygen partial pressure sensors.

    Science.gov (United States)

    Chen, R; Hahn, C E W; Farmery, A D

    2012-08-15

    The development of a methodology for testing the time response, linearity and performance characteristics of ultra fast fibre optic oxygen sensors in the liquid phase is presented. Two standard medical paediatric oxygenators are arranged to provide two independent extracorporeal circuits. Flow from either circuit can be diverted over the sensor under test by means of a system of rapid cross-over solenoid valves exposing the sensor to an abrupt change in oxygen partial pressure, P O2. The system is also capable of testing the oxygen sensor responses to changes in temperature, carbon dioxide partial pressure P CO2 and pH in situ. Results are presented for a miniature fibre optic oxygen sensor constructed in-house with a response time ≈ 50 ms and a commercial fibre optic sensor (Ocean Optics Foxy), when tested in flowing saline and stored blood. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Comparison of multiple linear regression, partial least squares and artificial neural networks for prediction of gas chromatographic relative retention times of trimethylsilylated anabolic androgenic steroids.

    Science.gov (United States)

    Fragkaki, A G; Farmaki, E; Thomaidis, N; Tsantili-Kakoulidou, A; Angelis, Y S; Koupparis, M; Georgakopoulos, C

    2012-09-21

    The comparison among different modelling techniques, such as multiple linear regression, partial least squares and artificial neural networks, has been performed in order to construct and evaluate models for prediction of gas chromatographic relative retention times of trimethylsilylated anabolic androgenic steroids. The performance of the quantitative structure-retention relationship study, using the multiple linear regression and partial least squares techniques, has been previously conducted. In the present study, artificial neural networks models were constructed and used for the prediction of relative retention times of anabolic androgenic steroids, while their efficiency is compared with that of the models derived from the multiple linear regression and partial least squares techniques. For overall ranking of the models, a novel procedure [Trends Anal. Chem. 29 (2010) 101-109] based on sum of ranking differences was applied, which permits the best model to be selected. The suggested models are considered useful for the estimation of relative retention times of designer steroids for which no analytical data are available. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Quantifying [{sup 18}F]fluorodeoxyglucose uptake in the arterial wall: the effects of dual time-point imaging and partial volume effect correction

    Energy Technology Data Exchange (ETDEWEB)

    Blomberg, Bjoern A. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark); Bashyam, Arjun; Ramachandran, Abhinay; Gholami, Saeid; Houshmand, Sina; Salavati, Ali; Werner, Tom; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); University of Groningen, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen (Netherlands)

    2015-08-15

    The human arterial wall is smaller than the spatial resolution of current positron emission tomographs. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake. We evaluated the impact of a novel method for partial volume effect (PVE) correction with contrast-enhanced CT (CECT) assistance on quantification of arterial wall {sup 18}F-FDG uptake at different imaging time-points. Ten subjects were assessed by CECT imaging and dual time-point PET/CT imaging at approximately 60 and 180 min after {sup 18}F-FDG administration. For both time-points, uptake of {sup 18}F-FDG was determined in the aortic wall by calculating the blood pool-corrected maximum standardized uptake value (cSUV{sub MAX}) and cSUV{sub MEAN}. The PVE-corrected SUV{sub MEAN} (pvcSUV{sub MEAN}) was also calculated using {sup 18}F-FDG PET/CT and CECT images. Finally, corresponding target-to-background ratios (TBR) were calculated. At 60 min, pvcSUV{sub MEAN} was on average 3.1 times greater than cSUV{sub MAX} (P <.0001) and 8.5 times greater than cSUV{sub MEAN} (P <.0001). At 180 min, pvcSUV{sub MEAN} was on average 2.6 times greater than cSUV{sub MAX} (P <.0001) and 6.6 times greater than cSUV{sub MEAN} (P <.0001). This study demonstrated that CECT-assisted PVE correction significantly influences quantification of arterial wall {sup 18}F-FDG uptake. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake with PET. (orig.)

  2. Mobility Effect on Poroelastic Seismic Signatures in Partially Saturated Rocks With Applications in Time-Lapse Monitoring of a Heavy Oil Reservoir

    Science.gov (United States)

    Zhao, Luanxiao; Yuan, Hemin; Yang, Jingkang; Han, De-hua; Geng, Jianhua; Zhou, Rui; Li, Hui; Yao, Qiuliang

    2017-11-01

    Conventional seismic analysis in partially saturated rocks normally lays emphasis on estimating pore fluid content and saturation, typically ignoring the effect of mobility, which decides the ability of fluids moving in the porous rocks. Deformation resulting from a seismic wave in heterogeneous partially saturated media can cause pore fluid pressure relaxation at mesoscopic scale, thereby making the fluid mobility inherently associated with poroelastic reflectivity. For two typical gas-brine reservoir models, with the given rock and fluid properties, the numerical analysis suggests that variations of patchy fluid saturation, fluid compressibility contrast, and acoustic stiffness of rock frame collectively affect the seismic reflection dependence on mobility. In particular, the realistic compressibility contrast of fluid patches in shallow and deep reservoir environments plays an important role in determining the reflection sensitivity to mobility. We also use a time-lapse seismic data set from a Steam-Assisted Gravity Drainage producing heavy oil reservoir to demonstrate that mobility change coupled with patchy saturation possibly leads to seismic spectral energy shifting from the baseline to monitor line. Our workflow starts from performing seismic spectral analysis on the targeted reflectivity interface. Then, on the basis of mesoscopic fluid pressure diffusion between patches of steam and heavy oil, poroelastic reflectivity modeling is conducted to understand the shift of the central frequency toward low frequencies after the steam injection. The presented results open the possibility of monitoring mobility change of a partially saturated geological formation from dissipation-related seismic attributes.

  3. 76 FR 55349 - Honey From Argentina: Notice of Extension of Time Limit for Preliminary Results and Partial...

    Science.gov (United States)

    2011-09-07

    ... requested administrative reviews for Asociacion de Cooperativas Argentinas (ACA), Alimentos Naturales... petitioners timely withdrew their request for review of the following companies: (1) Alimentos Naturales... companies: (1) Alimentos Naturales-Natural Foods Lavalle, (2) Alma Pura, (3) Apidouro Comercial Exportadora...

  4. Impact of warm ischemia time on the change of split renal function after minimally invasive partial nephrectomy in Taiwanese patients

    Directory of Open Access Journals (Sweden)

    Hung-Keng Li

    2015-01-01

    Conclusion: SRF is more sensitive for postoperative follow-up than eGFR. Longer warm ischemia time is associated with poorer postoperative renal function. RPN is a safe and feasible alternative to LPN.

  5. Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration.

    Science.gov (United States)

    Su, Li-Ming; Vagvolgyi, Balazs P; Agarwal, Rahul; Reiley, Carol E; Taylor, Russell H; Hager, Gregory D

    2009-04-01

    To investigate a markerless tracking system for real-time stereo-endoscopic visualization of preoperative computed tomographic imaging as an augmented display during robot-assisted laparoscopic partial nephrectomy. Stereoscopic video segments of a patient undergoing robot-assisted laparoscopic partial nephrectomy for tumor and another for a partial staghorn renal calculus were processed to evaluate the performance of a three-dimensional (3D)-to-3D registration algorithm. After both cases, we registered a segment of the video recording to the corresponding preoperative 3D-computed tomography image. After calibrating the camera and overlay, 3D-to-3D registration was created between the model and the surgical recording using a modified iterative closest point technique. Image-based tracking technology tracked selected fixed points on the kidney surface to augment the image-to-model registration. Our investigation has demonstrated that we can identify and track the kidney surface in real time when applied to intraoperative video recordings and overlay the 3D models of the kidney, tumor (or stone), and collecting system semitransparently. Using a basic computer research platform, we achieved an update rate of 10 Hz and an overlay latency of 4 frames. The accuracy of the 3D registration was 1 mm. Augmented reality overlay of reconstructed 3D-computed tomography images onto real-time stereo video footage is possible using iterative closest point and image-based surface tracking technology that does not use external navigation tracking systems or preplaced surface markers. Additional studies are needed to assess the precision and to achieve fully automated registration and display for intraoperative use.

  6. A fast direct method for block triangular Toeplitz-like with tri-diagonal block systems from time-fractional partial differential equations

    Science.gov (United States)

    Ke, Rihuan; Ng, Michael K.; Sun, Hai-Wei

    2015-12-01

    In this paper, we study the block lower triangular Toeplitz-like with tri-diagonal blocks system which arises from the time-fractional partial differential equation. Existing fast numerical solver (e.g., fast approximate inversion method) cannot handle such linear system as the main diagonal blocks are different. The main contribution of this paper is to propose a fast direct method for solving this linear system, and to illustrate that the proposed method is much faster than the classical block forward substitution method for solving this linear system. Our idea is based on the divide-and-conquer strategy and together with the fast Fourier transforms for calculating Toeplitz matrix-vector multiplication. The complexity needs O (MNlog2 ⁡ M) arithmetic operations, where M is the number of blocks (the number of time steps) in the system and N is the size (number of spatial grid points) of each block. Numerical examples from the finite difference discretization of time-fractional partial differential equations are also given to demonstrate the efficiency of the proposed method.

  7. Partial validation of a TaqMan real-time quantitative PCR for the detection of ranaviruses

    DEFF Research Database (Denmark)

    Stilwell, Natalie K.; Whittington, Richard J.; Hick, Paul M.

    2018-01-01

    Ranaviruses are globally emerging pathogens negatively impacting wild and cultured fish, amphibians, and reptiles. Although conventional and diagnostic real-time PCR (qPCR) assays have been developed to detect ranaviruses, these assays often have not been tested against the known diversity of ran...

  8. Effects of Injection Timing on Fluid Flow Characteristics of Partially Premixed Combustion Based on High-Speed Particle Image Velocimetry

    KAUST Repository

    Izadi Najafabadi, Mohammad; Tanov, Slavey; Wang, Hua; Somers, Bart; Johansson, Bengt; Dam, Nico

    2017-01-01

    behavior. The scope of the present study is to investigate the fluid flow characteristics of PPC at different injection timings. To this end, high-speed Particle Image Velocimetry (PIV) is implemented in a light-duty optical engine to measure fluid flow

  9. Partial Cancellation

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Partial Cancellation. Full Cancellation is desirable. But complexity requirements are enormous. 4000 tones, 100 Users billions of flops !!! Main Idea: Challenge: To determine which cross-talker to cancel on what “tone” for a given victim. Constraint: Total complexity is ...

  10. [Effect of tranilast on wound healing and administration time on scar hyperplasia of deep partial-thickness burn in mice].

    Science.gov (United States)

    Hu, Zhenzhen; Chen, Bin; Li, Yang; Jiang, Wei; Wen, Lihong; Ji, Fukang; Yang, Xiao; Wang, Jinhuang; Liu, Dalie

    2017-04-01

    To investigate the effect of tranilast on wound healing and the mechanism of inhibiting scar hyperplasia in mice, and to study the relationship between the inhibiting ability of tranilast on scar hyperplasia and administration time. Sixty-six Kunming mice were selected to build deep II degree burn model, and were randomly divided into the control group (18 mice), the early intervention group (18 mice), the medium intervention group (18 mice), and the late intervention group (12 mice). The mice in the early intervention group, the medium-term intervention group, and the late intervention group were given tranilast 200 mg/(kg·d) by gastrogavage at immediate, 7 days, and 14 days after burn respectively, and the mice in the control group were managed with same amount of normal saline every day. The wound healing was observed regularly. At 14, 28, and 42 days in the early and medium intervention groups and at 28 and 42 days in the late intervention group, fresh tissues were taken from 6 mice to observe the shape of mast cells by toluidine blue staining, collagen content by Masson staining; the collagen type I and collagen type III content were measured to calculate the I/III collagen content ratio by immunohistochemistry method, the contents of transforming growth factor β 1 (TGF-β 1 ) and histamine were detected by ELISA; and the ultrastructure of fibroblasts was observed under transmission electron microscope. There was no significant difference in wound healing time between groups ( F =1.105, P =0.371). The mast cells number, collagen content, TGF-β 1 content, histamine content, and the I/III collagen content ratio in the early intervention group were significantly less than those in the other groups ( P 0.05). Compared with the control group, the activity of fibroblasts in the early intervention group was obviously inhibited, and the arrangement of the fibers was more regular; the fibroblast activity in the medium and late intervention groups was also inhibited

  11. A method based on the Jacobi tau approximation for solving multi-term time-space fractional partial differential equations

    Science.gov (United States)

    Bhrawy, A. H.; Zaky, M. A.

    2015-01-01

    In this paper, we propose and analyze an efficient operational formulation of spectral tau method for multi-term time-space fractional differential equation with Dirichlet boundary conditions. The shifted Jacobi operational matrices of Riemann-Liouville fractional integral, left-sided and right-sided Caputo fractional derivatives are presented. By using these operational matrices, we propose a shifted Jacobi tau method for both temporal and spatial discretizations, which allows us to present an efficient spectral method for solving such problem. Furthermore, the error is estimated and the proposed method has reasonable convergence rates in spatial and temporal discretizations. In addition, some known spectral tau approximations can be derived as special cases from our algorithm if we suitably choose the corresponding special cases of Jacobi parameters θ and ϑ. Finally, in order to demonstrate its accuracy, we compare our method with those reported in the literature.

  12. Influence of hydrostatic pressure on dynamics and spatial distribution of protein partial molar volume: time-resolved surficial Kirkwood-Buff approach.

    Science.gov (United States)

    Yu, Isseki; Tasaki, Tomohiro; Nakada, Kyoko; Nagaoka, Masataka

    2010-09-30

    The influence of hydrostatic pressure on the partial molar volume (PMV) of the protein apomyoglobin (AMb) was investigated by all-atom molecular dynamics (MD) simulations. Using the time-resolved Kirkwood-Buff (KB) approach, the dynamic behavior of the PMV was identified. The simulated time average value of the PMV and its reduction by 3000 bar pressurization correlated with experimental data. In addition, with the aid of the surficial KB integral method, we obtained the spatial distributions of the components of PMV to elucidate the detailed mechanism of the PMV reduction. New R-dependent PMV profiles identified the regions that increase or decrease the PMV under the high pressure condition. The results indicate that besides the hydration in the vicinity of the protein surface, the outer space of the first hydration layer also significantly influences the total PMV change. These results provide a direct and detailed picture of pressure induced PMV reduction.

  13. Partial processing

    International Nuclear Information System (INIS)

    1978-11-01

    This discussion paper considers the possibility of applying to the recycle of plutonium in thermal reactors a particular method of partial processing based on the PUREX process but named CIVEX to emphasise the differences. The CIVEX process is based primarily on the retention of short-lived fission products. The paper suggests: (1) the recycle of fission products with uranium and plutonium in thermal reactor fuel would be technically feasible; (2) it would, however, take ten years or more to develop the CIVEX process to the point where it could be launched on a commercial scale; (3) since the majority of spent fuel to be reprocessed this century will have been in storage for ten years or more, the recycling of short-lived fission products with the U-Pu would not provide an effective means of making refabrication fuel ''inaccessible'' because the radioactivity associated with the fission products would have decayed. There would therefore be no advantage in partial processing

  14. Partial gigantism

    Directory of Open Access Journals (Sweden)

    М.М. Karimova

    2017-05-01

    Full Text Available A girl with partial gigantism (the increased I and II fingers of the left foot is being examined. This condition is a rare and unresolved problem, as the definite reason of its development is not determined. Wait-and-see strategy is recommended, as well as correcting operations after closing of growth zones, and forming of data pool for generalization and development of schemes of drug and radial therapeutic methods.

  15. Induction of Liver Cell Adenomata in the Rat by a Single Treatment with N-Methyl-N-Nitrosourea given at Various Times after Partial Hepatectomy

    Science.gov (United States)

    Craddock, V. M.; Frei, J. V.

    1974-01-01

    A single treatment of adult animals with the potent carcinogen NMU was known to induce tumours in a wide variety of organs, with the notable exception of liver. Administration of NMU after partial hepatectomy gave rise to the first liver cell adenomata ever observed in rats due to this carcinogen. The tumours were induced when NMU was given during the period of increased DNA synthesis but not when given early in the pre-replicative period. Although tumours were induced in other organs, the incidence of these did not correlate with the timing of NMU administration. It is suggested that replication of damaged DNA may be a relevant event in carcinogenesis. ImagesFig.p507-a PMID:4614856

  16. View-sharing in keyhole imaging: Partially compressed central k-space acquisition in time-resolved MRA at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Hadizadeh, Dariusch R., E-mail: Dariusch.Hadizadeh@ukb.uni-bonn.de [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Philips Healthcare, Best (Netherlands); Beck, Gabriele; Geerts, Liesbeth [Philips Healthcare, Best (Netherlands); Kukuk, Guido M. [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Bostroem, Azize [Department of Neurosurgery, Sigmund-Freud-Strasse 25, 53127 Bonn, Deutschland (Germany); Urbach, Horst; Schild, Hans H.; Willinek, Winfried A. [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany)

    2011-11-15

    Introduction: Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CEMRA) of the intracranial vasculature has proved its clinical value for the evaluation of cerebral vascular disease in cases where both flow hemodynamics and morphology are important. The purpose of this study was to evaluate a combination of view-sharing with keyhole imaging to increase spatial and temporal resolution of time-resolved CEMRA at 3.0 T. Methods: Alternating view-sharing was combined with randomly segmented k-space ordering, keyhole imaging, partial Fourier and parallel imaging (4DkvsMRA). 4DkvsMRA was evaluated using varying compression factors (80-100) resulting in spatial resolutions ranging from (1.1 x 1.1 x 1.4) to (0.96 x 0.96 x 0.95) mm{sup 3} and temporal resolutions ranging from 586 ms/dynamic scan - 288 ms/dynamic scan in three protocols in 10 healthy volunteers and seven patients (17 subjects). DSA correlation was available in four patients with cerebral arteriovenous malformations (cAVMs) and one patient with cerebral teleangiectasia. Results: 4DkvsMRA was successfully performed in all subjects and showed clear depiction of arterial and venous phases with diagnostic image quality. At the maximum view-sharing compression factor (=100), a 'flickering' artefact was observed. Conclusion: View-sharing in keyhole imaging allows for increased spatial and temporal resolution in time-resolved MRA.

  17. View-sharing in keyhole imaging: Partially compressed central k-space acquisition in time-resolved MRA at 3.0 T

    International Nuclear Information System (INIS)

    Hadizadeh, Dariusch R.; Gieseke, Juergen; Beck, Gabriele; Geerts, Liesbeth; Kukuk, Guido M.; Bostroem, Azize; Urbach, Horst; Schild, Hans H.; Willinek, Winfried A.

    2011-01-01

    Introduction: Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CEMRA) of the intracranial vasculature has proved its clinical value for the evaluation of cerebral vascular disease in cases where both flow hemodynamics and morphology are important. The purpose of this study was to evaluate a combination of view-sharing with keyhole imaging to increase spatial and temporal resolution of time-resolved CEMRA at 3.0 T. Methods: Alternating view-sharing was combined with randomly segmented k-space ordering, keyhole imaging, partial Fourier and parallel imaging (4DkvsMRA). 4DkvsMRA was evaluated using varying compression factors (80-100) resulting in spatial resolutions ranging from (1.1 x 1.1 x 1.4) to (0.96 x 0.96 x 0.95) mm 3 and temporal resolutions ranging from 586 ms/dynamic scan - 288 ms/dynamic scan in three protocols in 10 healthy volunteers and seven patients (17 subjects). DSA correlation was available in four patients with cerebral arteriovenous malformations (cAVMs) and one patient with cerebral teleangiectasia. Results: 4DkvsMRA was successfully performed in all subjects and showed clear depiction of arterial and venous phases with diagnostic image quality. At the maximum view-sharing compression factor (=100), a 'flickering' artefact was observed. Conclusion: View-sharing in keyhole imaging allows for increased spatial and temporal resolution in time-resolved MRA.

  18. Retroperitoneal versus transperitoneal robotic-assisted laparoscopic partial nephrectomy: a matched-pair, bicenter analysis with cost comparison using time-driven activity-based costing.

    Science.gov (United States)

    Laviana, Aaron A; Tan, Hung-Jui; Hu, Jim C; Weizer, Alon Z; Chang, Sam S; Barocas, Daniel A

    2018-03-01

    To perform a bicenter, retrospective study of perioperative outcomes of retroperitoneal versus transperitoneal robotic-assisted laparoscopic partial nephrectomy (RALPN) and assess costs using time-driven activity-based costing (TDABC). We identified 355 consecutive patients who underwent RALPN at University of California Los Angeles and the University of Michigan during 2009-2016. We matched according to RENAL nephrometry score, date, and institution for 78 retroperitoneal versus 78 transperitoneal RALPN. Unadjusted analyses were performed using McNemar's Chi-squared or paired t test, and adjusted analyses were performed using multivariable repeated measures regression analysis. From multivariable models, predicted probabilities were derived according to approach. Cost analysis was performed using TDABC. Patients treated with retroperitoneal versus transperitoneal RALPN were similar in age (P = 0.490), sex (P = 0.715), BMI (P = 0.273), and comorbidity (P = 0.393). Most tumors were posterior or lateral in both the retroperitoneal (92.3%) and transperitoneal (85.9%) groups. Retroperitoneal RALPN was associated with shorter operative times (167.0 versus 191.1 min, P = 0.001) and length of stay (LOS) (1.8 versus 2.7 days, P factoring in disposable equipment, operative time, LOS, and personnel. In two high-volume, tertiary centers, retroperitoneal RALPN is associated with reduced operative times and shortened LOS in posterior and lateral tumors, whereas sharing similar clinicopathologic outcomes, which may translate into lower healthcare costs. Further investigation into anterior tumors is needed.

  19. Partial substitution of NaCl by KCl and addition of flavor enhancers on probiotic Prato cheese: A study covering manufacturing, ripening and storage time.

    Science.gov (United States)

    Silva, Hugo L A; Balthazar, Celso F; Esmerino, Erick A; Neto, Roberto P C; Rocha, Ramon S; Moraes, Jeremias; Cavalcanti, Rodrigo N; Franco, Robson M; Tavares, Maria Inês B; Santos, Jânio S; Granato, Daniel; Costa, Renata G B; Freitas, Mônica Q; Silva, Márcia C; Raices, Renata S L; Senaka Ranadheera, C; Nazzaro, Filomena; Mortazavian, Amir M; Cruz, Adriano G

    2018-05-15

    Cheese is a suitable matrix to deliver probiotic strains but it contains a high amount of sodium. The effect of partial substitution of NaCl by KCl and the addition of flavor enhancers (l-arginine, yeast and oregano extract) on probiotic Prato cheese was investigated after 1, 30, and 60 d of refrigerated storage (immediately after manufacturing, and during ripening and storage). Microbiological (lactic acid bacteria and probiotic Lactobacillus casei 01 counts and survival under gastrointestinal conditions), physicochemical (pH, proteolysis, fatty acids), bioactivity (antioxidant effect and angiotensin I-converting enzyme inhibitory activity), rheological, and water mobility by means of time domain low-field nuclear magnetic resonance were investigated. Significant changes in probiotic survival were observed; however, the sodium reduction and the addition of flavor enhancers did not constitute an obstacle to L. casei 01 (>10 8  CFU/g) during storage. Slight changes were observed in proteolysis, bioactivity, water mobility, texture profile, and fatty acids of the cheeses as a function of the flavor enhancer added. The sodium reduction and the supplementation of Prato cheese with probiotic cultures may be an effective alternative to the production of a potentially functional cheese. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Measurement of Time-Dependent CP-Violating Asymmetriesand Constraints on sin(2 beta+gamma) withPartial Reconstruction of B to D*-+pi+- Decays

    Energy Technology Data Exchange (ETDEWEB)

    Aubert, B.

    2005-04-19

    We present a measurement of the time-dependent CP-violating asymmetries in decays of neutral B mesons to the final states D*{sup {-+}}{pi}{sup {+-}}, using approximately 232 million B{bar B} events recorded by the BABAR experiment at the PEP-II e{sup +}e{sup -} storage ring. Events containing these decays are selected with a partial reconstruction technique, in which only the high-momentum {pi}{sup {+-}} from the B decay and the low-momentum {pi}{sup {-+}} from the D*{sup {-+}} decay are used. We measure the parameters related to 2{beta} + {gamma} to be a{sub D*{pi}} = -0.034 {+-} 0.014 {+-} 0.009 and c{sub D*{pi}}{sup {ell}} = -0.019 {+-} 0.022 {+-} 0.013. With some theoretical assumptions, we interpret our results in terms of the lower limits |sin(2{beta} + {gamma})| > 0.62 (0.35) at 68% (90%) confidence level.

  1. Time required for partial pressure of arterial oxygen equilibration during mechanical ventilation after a step change in fractional inspired oxygen concentration.

    Science.gov (United States)

    Cakar, N; Tuŏrul, M; Demirarslan, A; Nahum, A; Adams, A; Akýncý, O; Esen, F; Telci, L

    2001-04-01

    To determine the time required for the partial pressure of arterial oxygen (PaO2) to reach equilibrium after a 0.20 increment or decrement in fractional inspired oxygen concentration (FIO2) during mechanical ventilation. A multi-disciplinary ICU in a university hospital. Twenty-five adult, non-COPD patients with stable blood gas values (PaO2/FIO2 > or = 180 on the day of the study) on pressure-controlled ventilation (PCV). Following a baseline PaO2 (PaO2b) measurement at FIO2 = 0.35, the FIO2 was increased to 0.55 for 30 min and then decreased to 0.35 without any other change in ventilatory parameters. Sequential blood gas measurements were performed at 3, 5, 7, 9, 11, 15, 20, 25 and 30 min in both periods. The PaO2 values measured at the 30th min after a step change in FIO2 (FIO2 = 0.55, PaO2[55] and FIO2 = 0.35, PaO2[35]) were accepted as representative of the equilibrium values for PaO2. Each patient's rise and fall in PaO2 over time, PaO2(t), were fitted to the following respective exponential equations: PaO2b + (PaO2[55]-PaO2b)(1-e-kt) and PaO2[55] + (PaO2[35]-PaO2[55])(e-kt) where "t" refers to time, PaO2[55] and PaO2[35] are the final PaO2 values obtained at a new FIO2 of 0.55 and 0.35, after a 0.20 increment and decrement in FIO2, respectively. Time constant "k" was determined by a non-linear fitting curve and 90% oxygenation times were defined as the time required to reach 90% of the final equilibrated PaO2 calculated by using the non-linear fitting curves. Time constant values for the rise and fall periods were 1.01 +/- 0.71 min-1, 0.69 +/- 0.42 min-1, respectively, and 90% oxygenation times for rises and falls in PaO2 periods were 4.2 +/- 4.1 min-1 and 5.5 +/- 4.8 min-1, respectively. There was no significant difference between the rise and fall periods for the two parameters (p > 0.05). We conclude that in stable patients ventilated with PCV, after a step change in FIO2 of 0.20, 5-10 min will be adequate for obtaining a blood gas sample to measure a Pa

  2. Hydrogen production with short contact time. Catalytic partial oxidation of hydrocarbons and oxygenated compounds: Recent advances in pilot- and bench-scale testing and process design

    Energy Technology Data Exchange (ETDEWEB)

    Guarinoni, A.; Ponzo, R.; Basini, L. [ENI Refining and Marketing Div., San Donato Milanese (Italy)

    2010-12-30

    ENI R and D has been active for fifteen years in the development of Short Contact Time - Catalytic Partial Oxidation (SCT-CPO) technologies for producing Hydrogen/Synthesis Gas. From the beginning the experimental work addressed either at defining the fundamental principles or the technical and economical potential of the technology. Good experimental responses, technical solutions' simplicity and flexibility, favourable techno-economical evaluations promoted the progressive widening of the field of the investigations. From Natural Gas (NG) the range of ''processable'' Hydrocarbons extended to Liquefied Petroleum Gas (LPG) and Gasoils, including those characterised by high levels of unsaturated and sulphurated molecules and, lately, to other compounds with biological origin. The extensive work led to the definition of different technological solutions, grouped as follows: Technology 1: Air Blown SCT-CPO of Gaseous Hydrocarbons and/or Light Compounds with biological origin Technology 2: Enriched Air/Oxygen Blown SCT-CPO of Gaseous Hydrocarbons and/or Light Compounds with biological origin Technology 3: Enriched Air/Oxygen Blown SCT-CPO of Liquid Hydrocarbons and/or Compounds with biological origin Recently, the licence rights on a non-exclusive basis for the commercialisation of SCT-CPO based processes for H{sub 2}/Synthesis gas production from light hydrocarbons with production capacity lower than 5,000 Nm{sup 3}/h of H{sub 2} or 7,500 Nm3/h of syngas have been assigned to two external companies. In parallel, development of medium- and large-scale plant solutions is progressing within the ENI group framework. These last activities are addressed to the utilisation of SCT-CPO for matching the variable Hydrogen demand in several contexts of oil refining operation. This paper will report on the current status of SCT-CPO with a focus on experimental results obtained, either at pilot- and bench- scale level. (orig.)

  3. Anatomic partial nephrectomy: technique evolution.

    Science.gov (United States)

    Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S

    2015-03-01

    Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.

  4. A Comparative Analysis of the Value of Information in a Continuous Time Market Model with Partial Information: The Cases of Log-Utility and CRRA

    Directory of Open Access Journals (Sweden)

    Zhaojun Yang

    2011-01-01

    Full Text Available We study the question what value an agent in a generalized Black-Scholes model with partial information attributes to the complementary information. To do this, we study the utility maximization problems from terminal wealth for the two cases partial information and full information. We assume that the drift term of the risky asset is a dynamic process of general linear type and that the two levels of observation correspond to whether this drift term is observable or not. Applying methods from stochastic filtering theory we derive an analytical tractable formula for the value of information in the case of logarithmic utility. For the case of constant relative risk aversion (CRRA we derive a semianalytical formula, which uses as an input the numerical solution of a system of ODEs. For both cases we present a comparative analysis.

  5. PARALLEL SOLUTION METHODS OF PARTIAL DIFFERENTIAL EQUATIONS

    Directory of Open Access Journals (Sweden)

    Korhan KARABULUT

    1998-03-01

    Full Text Available Partial differential equations arise in almost all fields of science and engineering. Computer time spent in solving partial differential equations is much more than that of in any other problem class. For this reason, partial differential equations are suitable to be solved on parallel computers that offer great computation power. In this study, parallel solution to partial differential equations with Jacobi, Gauss-Siedel, SOR (Succesive OverRelaxation and SSOR (Symmetric SOR algorithms is studied.

  6. [Removable partial dentures. Oral functions and types].

    Science.gov (United States)

    Creugers, N H J; de Baat, C

    2009-11-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combination of interrupted as well as free-ending tooth arches can be restored using these dentures. Well-known disadvantages of removable partial dentures are problematic oral hygiene, negative influence on the remaining dentition and limited oral comfort. Due to the advanced possibilities of fixed tooth- or implant-supported partial dentures, whether or not free-ending, or tooth- as well as implant-supported partial dentures, the indication of removable partial dentures is restricted. Nevertheless, for the time being the demand for removable partial dentures is expected to continue.

  7. Partial tooth gear bearings

    Science.gov (United States)

    Vranish, John M. (Inventor)

    2010-01-01

    A partial gear bearing including an upper half, comprising peak partial teeth, and a lower, or bottom, half, comprising valley partial teeth. The upper half also has an integrated roller section between each of the peak partial teeth with a radius equal to the gear pitch radius of the radially outwardly extending peak partial teeth. Conversely, the lower half has an integrated roller section between each of the valley half teeth with a radius also equal to the gear pitch radius of the peak partial teeth. The valley partial teeth extend radially inwardly from its roller section. The peak and valley partial teeth are exactly out of phase with each other, as are the roller sections of the upper and lower halves. Essentially, the end roller bearing of the typical gear bearing has been integrated into the normal gear tooth pattern.

  8. Group B streptococcal septicemia of the newborn

    Science.gov (United States)

    ... time ( PT ) and partial thromboplastin time ( PTT ) Blood gases (to see if the baby needs help with ... 2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing by ADAM ...

  9. High risk of coagulopathy among Type-2 Diabetes Mellitus clients at ...

    African Journals Online (AJOL)

    Background: Persistent hyperglycaemia in diabetes mellitus causes coagulopathies due to glycation of haemoglobin, prothrombin, fibrinogen and other proteins involved in the clotting mechanism. Shortened activated partial thromboplastin time (APTT) and prothrombin time (PT) reflect hypercoagulable state, which is ...

  10. Essays on partial retirement

    NARCIS (Netherlands)

    Kantarci, T.

    2012-01-01

    The five essays in this dissertation address a range of topics in the micro-economic literature on partial retirement. The focus is on the labor market behavior of older age groups. The essays examine the economic and non-economic determinants of partial retirement behavior, the effect of partial

  11. Recurrent Partial Words

    Directory of Open Access Journals (Sweden)

    Francine Blanchet-Sadri

    2011-08-01

    Full Text Available Partial words are sequences over a finite alphabet that may contain wildcard symbols, called holes, which match or are compatible with all letters; partial words without holes are said to be full words (or simply words. Given an infinite partial word w, the number of distinct full words over the alphabet that are compatible with factors of w of length n, called subwords of w, refers to a measure of complexity of infinite partial words so-called subword complexity. This measure is of particular interest because we can construct partial words with subword complexities not achievable by full words. In this paper, we consider the notion of recurrence over infinite partial words, that is, we study whether all of the finite subwords of a given infinite partial word appear infinitely often, and we establish connections between subword complexity and recurrence in this more general framework.

  12. Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm

    International Nuclear Information System (INIS)

    Wintersperger, Bernd J.; Nikolaou, Konstantin; Dietrich, Olaf; Reiser, Maximilian F.; Schoenberg, Stefan O.; Rieber, Johannes; Nittka, Matthias

    2003-01-01

    The purpose of this study was to test parallel imaging techniques for improvement of temporal resolution in multislice single breath-hold real-time cine steady-state free precession (SSFP) in comparison with standard segmented single-slice SSFP techniques. Eighteen subjects were examined on a 1.5-T scanner using a multislice real-time cine SSFP technique using the GRAPPA algorithm. Global left ventricular parameters (EDV, ESV, SV, EF) were evaluated and results compared with a standard segmented single-slice SSFP technique. Results for EDV (r=0.93), ESV (r=0.99), SV (r=0.83), and EF (r=0.99) of real-time multislice SSFP imaging showed a high correlation with results of segmented SSFP acquisitions. Systematic differences between both techniques were statistically non-significant. Single breath-hold multislice techniques using GRAPPA allow for improvement of temporal resolution and for accurate assessment of global left ventricular functional parameters. (orig.)

  13. A comparison of the Method of Lines to finite difference techniques in solving time-dependent partial differential equations. [with applications to Burger equation and stream function-vorticity problem

    Science.gov (United States)

    Kurtz, L. A.; Smith, R. E.; Parks, C. L.; Boney, L. R.

    1978-01-01

    Steady state solutions to two time dependent partial differential systems have been obtained by the Method of Lines (MOL) and compared to those obtained by efficient standard finite difference methods: (1) Burger's equation over a finite space domain by a forward time central space explicit method, and (2) the stream function - vorticity form of viscous incompressible fluid flow in a square cavity by an alternating direction implicit (ADI) method. The standard techniques were far more computationally efficient when applicable. In the second example, converged solutions at very high Reynolds numbers were obtained by MOL, whereas solution by ADI was either unattainable or impractical. With regard to 'set up' time, solution by MOL is an attractive alternative to techniques with complicated algorithms, as much of the programming difficulty is eliminated.

  14. Using Simulated Partial Dynamic Run-Time Reconfiguration to Share Embedded FPGA Compute and Power Resources across a Swarm of Unpiloted Airborne Vehicles

    Directory of Open Access Journals (Sweden)

    Kearney David

    2007-01-01

    Full Text Available We show how the limited electrical power and FPGA compute resources available in a swarm of small UAVs can be shared by moving FPGA tasks from one UAV to another. A software and hardware infrastructure that supports the mobility of embedded FPGA applications on a single FPGA chip and across a group of networked FPGA chips is an integral part of the work described here. It is shown how to allocate a single FPGA's resources at run time and to share a single device through the use of application checkpointing, a memory controller, and an on-chip run-time reconfigurable network. A prototype distributed operating system is described for managing mobile applications across the swarm based on the contents of a fuzzy rule base. It can move applications between UAVs in order to equalize power use or to enable the continuous replenishment of fully fueled planes into the swarm.

  15. Energy-based operator splitting approach for the time discretization of coupled systems of partial and ordinary differential equations for fluid flows: The Stokes case

    Science.gov (United States)

    Carichino, Lucia; Guidoboni, Giovanna; Szopos, Marcela

    2018-07-01

    The goal of this work is to develop a novel splitting approach for the numerical solution of multiscale problems involving the coupling between Stokes equations and ODE systems, as often encountered in blood flow modeling applications. The proposed algorithm is based on a semi-discretization in time based on operator splitting, whose design is guided by the rationale of ensuring that the physical energy balance is maintained at the discrete level. As a result, unconditional stability with respect to the time step choice is ensured by the implicit treatment of interface conditions within the Stokes substeps, whereas the coupling between Stokes and ODE substeps is enforced via appropriate initial conditions for each substep. Notably, unconditional stability is attained without the need of subiterating between Stokes and ODE substeps. Stability and convergence properties of the proposed algorithm are tested on three specific examples for which analytical solutions are derived.

  16. Off-Stream Watering Systems and Partial Barriers as a Strategy to Maximize Cattle Production and Minimize Time Spent in the Riparian Area

    Directory of Open Access Journals (Sweden)

    Ashley A. Rawluk

    2014-10-01

    Full Text Available A study was conducted in 2009 at two locations in Manitoba (Killarney and Souris, Canada to determine the impact of off-stream waterers (OSW with or without natural barriers on (i amount of time cattle spent in the 10 m buffer created within the riparian area, referred to as the riparian polygon (RP, (ii watering location (OSW or stream, and (iii animal performance measured as weight gain. This study was divided into three 28-day periods over the grazing season. At each location, the pasture—which ranged from 21.0 ha to 39.2 ha in size—was divided into three treatments: no OSW nor barriers (1CONT, OSW with barriers along the stream bank to deter cattle from watering at the stream (2BARR, and OSW without barriers (3NOBARR. Cattle in 2BARR spent less time in the RP in Periods 1 (p = 0.0002, 2 (p = 0.1116, and 3 (p < 0.0001 at the Killarney site compared to cattle in 3NOBARR at the same site. Cattle in 2BARR at the Souris site spent more time in the RP in Period 1 (p < 0.0001 and less time in Period 2 (p = 0.0002 compared to cattle in 3NOBARR. Cattle did use the OSW, but not exclusively, as watering at the stream was still observed. The observed inconsistency in the effectiveness of the natural barriers on deterring cattle from the riparian area between periods and locations may be partly attributable to the environmental conditions present during this field trial as well as difference in pasture size and the ability of the established barriers to deter cattle from using the stream as a water source. Treatment had no significant effect (p > 0.05 on cow and calf weights averaged over the summer period. These results indicate that the presence of an OSW does not create significant differences in animal performance when used in extensive pasture scenarios such as those studied within the present study. Whereas the barriers did not consistently discourage watering at the stream, the results provide some indication of the efficacy of the OSW as well

  17. Limits of applicability of a time-of-flight ion-mass analyzer in uncovering partial currents of ions emitted by pulsed laser ion sources

    Czech Academy of Sciences Publication Activity Database

    Krása, Josef; Láska, Leoš; Rohlena, Karel; Velyhan, Andriy; Czarnecka, A.; Parys, P.; Ryc, L.; Wolowski, J.

    2010-01-01

    Roč. 165, 6-10 (2010), s. 441-450 ISSN 1042-0150 R&D Projects: GA MŠk(CZ) LC528; GA AV ČR IAA100100715 EU Projects: European Commission(XE) 228334 - LASERLAB-EUROPE Institutional research plan: CEZ:AV0Z10100523 Keywords : laser-produced plasma * time-resolved current deconvolution * ion velocity distribution * drift velocity of ions Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.660, year: 2010

  18. Landsliding in partially saturated materials

    Science.gov (United States)

    Godt, J.W.; Baum, R.L.; Lu, N.

    2009-01-01

    [1] Rainfall-induced landslides are pervasive in hillslope environments around the world and among the most costly and deadly natural hazards. However, capturing their occurrence with scientific instrumentation in a natural setting is extremely rare. The prevailing thinking on landslide initiation, particularly for those landslides that occur under intense precipitation, is that the failure surface is saturated and has positive pore-water pressures acting on it. Most analytic methods used for landslide hazard assessment are based on the above perception and assume that the failure surface is located beneath a water table. By monitoring the pore water and soil suction response to rainfall, we observed shallow landslide occurrence under partially saturated conditions for the first time in a natural setting. We show that the partially saturated shallow landslide at this site is predictable using measured soil suction and water content and a novel unified effective stress concept for partially saturated earth materials. Copyright 2009 by the American Geophysical Union.

  19. Construction of a novel lentiviral vector carrying human B-domain ...

    African Journals Online (AJOL)

    USER

    2010-03-29

    Mar 29, 2010 ... Construction of the lentiviral expression vector. Both self-inactivating (SIN) ..... activated partial thromboplastin time. Figure 4. Expression of ... 1 entry to an endocytic pathway and suppresses both the requirement for Nef and ...

  20. Parachute technique for partial penectomy

    Directory of Open Access Journals (Sweden)

    Fernando Korkes

    2010-04-01

    Full Text Available PURPOSE: Penile carcinoma is a rare but mutilating malignancy. In this context, partial penectomy is the most commonly applied approach for best oncological results. We herein propose a simple modification of the classic technique of partial penectomy, for better cosmetic and functional results. TECHNIQUE: If partial penectomy is indicated, the present technique can bring additional benefits. Different from classical technique, the urethra is spatulated only ventrally. An inverted "V" skin flap with 0.5 cm of extension is sectioned ventrally. The suture is performed with vicryl 4-0 in a "parachute" fashion, beginning from the ventral portion of the urethra and the "V" flap, followed by the "V" flap angles and than by the dorsal portion of the penis. After completion of the suture, a Foley catheter and light dressing are placed for 24 hours. CONCLUSIONS: Several complex reconstructive techniques have been previously proposed, but normally require specific surgical abilities, adequate patient selection and staged procedures. We believe that these reconstructive techniques are very useful in some specific subsets of patients. However, the technique herein proposed is a simple alternative that can be applied to all men after a partial penectomy, and takes the same amount of time as that in the classic technique. In conclusion, the "parachute" technique for penile reconstruction after partial amputation not only improves the appearance of the penis, but also maintains an adequate function.

  1. Off-Stream Watering Systems and Partial Barriers as a Strategy to Maximize Cattle Production and Minimize Time Spent in the Riparian Area.

    Science.gov (United States)

    Rawluk, Ashley A; Crow, Gary; Legesse, Getahun; Veira, Douglas M; Bullock, Paul R; González, Luciano A; Dubois, Melanie; Ominski, Kim H

    2014-10-29

    A study was conducted in 2009 at two locations in Manitoba (Killarney and Souris), Canada to determine the impact of off-stream waterers (OSW) with or without natural barriers on (i) amount of time cattle spent in the 10 m buffer created within the riparian area, referred to as the riparian polygon (RP), (ii) watering location (OSW or stream), and (iii) animal performance measured as weight gain. This study was divided into three 28-day periods over the grazing season. At each location, the pasture-which ranged from 21.0 ha to 39.2 ha in size-was divided into three treatments: no OSW nor barriers (1CONT), OSW with barriers along the stream bank to deter cattle from watering at the stream (2BARR), and OSW without barriers (3NOBARR). Cattle in 2BARR spent less time in the RP in Periods 1 (p = 0.0002), 2 (p = 0.1116), and 3 (p natural barriers on deterring cattle from the riparian area between periods and locations may be partly attributable to the environmental conditions present during this field trial as well as difference in pasture size and the ability of the established barriers to deter cattle from using the stream as a water source. Treatment had no significant effect (p > 0.05) on cow and calf weights averaged over the summer period. These results indicate that the presence of an OSW does not create significant differences in animal performance when used in extensive pasture scenarios such as those studied within the present study. Whereas the barriers did not consistently discourage watering at the stream, the results provide some indication of the efficacy of the OSW as well as the natural barriers on deterring cattle from the riparian area.

  2. Detection and partial discrimination of atypical and classical bovine spongiform encephalopathies in cattle and primates using real-time quaking-induced conversion assay.

    Science.gov (United States)

    Levavasseur, Etienne; Biacabe, Anne-Gaëlle; Comoy, Emmanuel; Culeux, Audrey; Grznarova, Katarina; Privat, Nicolas; Simoneau, Steve; Flan, Benoit; Sazdovitch, Véronique; Seilhean, Danielle; Baron, Thierry; Haïk, Stéphane

    2017-01-01

    The transmission of classical bovine spongiform encephalopathy (C-BSE) through contaminated meat product consumption is responsible for variant Creutzfeldt-Jakob disease (vCJD) in humans. More recent and atypical forms of BSE (L-BSE and H-BSE) have been identified in cattle since the C-BSE epidemic. Their low incidence and advanced age of onset are compatible with a sporadic origin, as are most cases of Creutzfeldt-Jakob disease (CJD) in humans. Transmissions studies in primates and transgenic mice expressing a human prion protein (PrP) indicated that atypical forms of BSE may be associated with a higher zoonotic potential than classical BSE, and require particular attention for public health. Recently, methods designed to amplify misfolded forms of PrP have emerged as promising tools to detect prion strains and to study their diversity. Here, we validated real-time quaking-induced conversion assay for the discrimination of atypical and classical BSE strains using a large series of bovine samples encompassing all the atypical BSE cases detected by the French Centre of Reference during 10 years of exhaustive active surveillance. We obtained a 100% sensitivity and specificity for atypical BSE detection. In addition, the assay was able to discriminate atypical and classical BSE in non-human primates, and also sporadic CJD and vCJD in humans. The RT-QuIC assay appears as a practical means for a reliable detection of atypical BSE strains in a homologous or heterologous PrP context.

  3. Partial scram incident in FBTR

    International Nuclear Information System (INIS)

    Usha, S.; Pillai, C.P.; Muralikrishna, G.

    1989-01-01

    Evaluation of a partial scram incident occurred at the Fast Breeder Test Reactor at Kalpakkam was carried out. Based on the observations of the experiments it was ascertained that the nonpersistant order was due to superimposed noise component on the channel that was close to the threshold and had resulted in intermittent supply to electro-magnetic (EM) coils. Owing to a larger discharge time and a smaller charge time, the EM coils got progressively discharged. It was confirmed that during the incident, partial scram took place since the charging and discharging patterns of the EM coils are dissimilar and EM coils of rods A, E and F had discharged faster than others for noise component of a particular duty cycle. However, nonlatching of scram order was because of the fact that noise pulse duration was less than latching time. (author)

  4. Hyperbolic partial differential equations

    CERN Document Server

    Witten, Matthew

    1986-01-01

    Hyperbolic Partial Differential Equations III is a refereed journal issue that explores the applications, theory, and/or applied methods related to hyperbolic partial differential equations, or problems arising out of hyperbolic partial differential equations, in any area of research. This journal issue is interested in all types of articles in terms of review, mini-monograph, standard study, or short communication. Some studies presented in this journal include discretization of ideal fluid dynamics in the Eulerian representation; a Riemann problem in gas dynamics with bifurcation; periodic M

  5. Successful removable partial dentures.

    Science.gov (United States)

    Lynch, Christopher D

    2012-03-01

    Removable partial dentures (RPDs) remain a mainstay of prosthodontic care for partially dentate patients. Appropriately designed, they can restore masticatory efficiency, improve aesthetics and speech, and help secure overall oral health. However, challenges remain in providing such treatments, including maintaining adequate plaque control, achieving adequate retention, and facilitating patient tolerance. The aim of this paper is to review the successful provision of RPDs. Removable partial dentures are a successful form of treatment for replacing missing teeth, and can be successfully provided with appropriate design and fabrication concepts in mind.

  6. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2011-01-01

    A rigorous, yet accessible, introduction to partial differential equations-updated in a valuable new edition Beginning Partial Differential Equations, Second Edition provides a comprehensive introduction to partial differential equations (PDEs) with a special focus on the significance of characteristics, solutions by Fourier series, integrals and transforms, properties and physical interpretations of solutions, and a transition to the modern function space approach to PDEs. With its breadth of coverage, this new edition continues to present a broad introduction to the field, while also addres

  7. Partial pressure (or fugacity) of carbon dioxide, salinity and SEA SURFACE TEMPERATURE collected from time series observations using Carbon dioxide (CO2) gas analyzer, Shower head chamber equilibrator for autonomous carbon dioxide (CO2) measurement and other instruments from Polaris II in the South Pacific Ocean from 2006-08-29 to 2006-10-24 (NODC Accession 0112883)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0112883 includes time series data collected from Polaris II in the South Pacific Ocean from 2006-08-29 to 2006-10-24. These data include Partial...

  8. Partial pressure of carbon dioxide, pH, oxygen and other variables collected from time series observations using SAMI-CO2, SAMI-pH, and other instruments from Buoy NH-10 off the coast of Newport, Oregon, United States, at the near bottom depth of ~80 meters from 2011-08-16 to 2015-08-25 (NCEI Accession 0145162)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains time series measurements of near bottom partial pressure of carbon dioxide, pH, dissolved oxygen that are measured from SAMI-CO2, and...

  9. The partial-birth stratagem.

    Science.gov (United States)

    1998-06-01

    In Wisconsin, physicians stopped performing abortions when a Federal District Court Judge refused to issue a temporary restraining order against the state's newly enacted "partial birth" abortion ban that was couched in such vague language it actually covered all abortions. While ostensibly attempting to ban late-term "intact dilation and extraction," the language of the law did not refer to that procedure or to late terms. Instead, it prohibited all abortions in which a physician "partially vaginally delivers a living child, causes the death of the partially delivered child with the intent to kill the child and then completes the delivery of the child." The law also defined "child" as "a human being from the time of fertilization" until birth. It is clear that this abortion ban is unconstitutional under Row v. Wade, and this unconstitutionality is compounded by the fact that the law allowed no exception to protect a woman's health, which is required by Roe for abortion bans after fetal viability. Wisconsin is only one of about 28 states that have enacted similar laws, and only two have restricted the ban to postviability abortions. Many of these laws have been struck down in court, and President Clinton has continued to veto the Federal partial-birth bill. The Wisconsin Judge acknowledged that opponents of the ban will likely prevail when the case is heard, but his action in denying the temporary injunction means that many women in Wisconsin will not receive timely medical care. The partial birth strategy is really only another anti-abortion strategy.

  10. Partial knee replacement - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100225.htm Partial knee replacement - series—Normal anatomy To use the sharing ... A.M. Editorial team. Related MedlinePlus Health Topics Knee Replacement A.D.A.M., Inc. is accredited ...

  11. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2014-01-01

    A broad introduction to PDEs with an emphasis on specialized topics and applications occurring in a variety of fields Featuring a thoroughly revised presentation of topics, Beginning Partial Differential Equations, Third Edition provides a challenging, yet accessible,combination of techniques, applications, and introductory theory on the subjectof partial differential equations. The new edition offers nonstandard coverageon material including Burger's equation, the telegraph equation, damped wavemotion, and the use of characteristics to solve nonhomogeneous problems. The Third Edition is or

  12. Renal function and plasma dabigatran level measured at trough by diluted thrombin time assay

    Directory of Open Access Journals (Sweden)

    Marta E. Martinuzzo

    2017-02-01

    Full Text Available Dabigatran etexilate (direct thrombin inhibitor is effective in preventing embolic stroke in patients with atrial fibrillation. It does not require laboratory control, but given the high renal elimination, its measurement in plasma is important in renal failure. The objectives of the study were to verify the analytical quality of the diluted thrombin time assay for measurement of dabigatran plasma concentration (cc, correlate cc with classic coagulation assays, prothrombin time (PT and activated partial thromboplastin time (APTT, and evaluate them according to the creatinine clearance (CLCr. Forty plasma samples of patients (34 consecutive and 6 suspected of drug accumulation receiving dabigatran at 150 (n = 19 or 110 (n = 21 mg/12 hours were collected. Blood samples were drawn at 10-14 hours of the last intake. Dabigatran concentration was determined by diluted thrombin time (HemosIl DTI, Instrumentation Laboratory (IL. PT and APTT (IL were performed on two fotooptical coagulometers, ACL TOP 300 and 500 (IL. DTI presented intra-assay coefficient of variation < 5.4% and inter-assay < 6%, linearity range 0-493 ng/ml. Patients' cc: median 83 (4-945 ng/ml. Individuals with CLCr in the lowest tertile (22.6-46.1 ml/min showed significantly higher median cc: 308 (49-945, compared to the average 72 (12-190 and highest tertile, 60 (4-118 ng/ml. Correlation between cc and APTT or PT were moderate, r2 = 0.59 and -0.66, p < 0.0001, respectively. DTI test allowed us to quantify plasma dabigatran levels, both in patients with normal or altered renal function, representing a useful tool in clinical situations such as renal failure, pre surgery or emergencies

  13. Honey Bee Venom (Apis mellifera) Contains Anticoagulation Factors and Increases the Blood-clotting Time.

    Science.gov (United States)

    Zolfagharian, Hossein; Mohajeri, Mohammad; Babaie, Mahdi

    2015-12-01

    Bee venom (BV) is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera) on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50), and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Blood samples were obtained from 10 rabbits, and the prothrombin time (PT) and the partial thromboplastin time (PTT) tests were conducted. The approximate lethal dose (LD) values of BV were determined. Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs) = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa), respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2) and melittin, and that can increase the blood clotting times in vitro.

  14. Honey Bee Venom (Apis mellifera Contains Anticoagulation Factors and Increases the Blood-clotting Time

    Directory of Open Access Journals (Sweden)

    Hossein Zolfagharian

    2015-12-01

    Full Text Available Objectives: Bee venom (BV is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Methods: Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50, and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE. Blood samples were obtained from 10 rabbits, and the prothrombin time (PT and the partial thromboplastin time (PTT tests were conducted. The approximate lethal dose (LD values of BV were determined. Results: Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa, respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. Conclusion: BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2 and melittin, and that can increase the blood clotting times in vitro.

  15. Partial differential equations

    CERN Document Server

    Evans, Lawrence C

    2010-01-01

    This text gives a comprehensive survey of modern techniques in the theoretical study of partial differential equations (PDEs) with particular emphasis on nonlinear equations. The exposition is divided into three parts: representation formulas for solutions; theory for linear partial differential equations; and theory for nonlinear partial differential equations. Included are complete treatments of the method of characteristics; energy methods within Sobolev spaces; regularity for second-order elliptic, parabolic, and hyperbolic equations; maximum principles; the multidimensional calculus of variations; viscosity solutions of Hamilton-Jacobi equations; shock waves and entropy criteria for conservation laws; and, much more.The author summarizes the relevant mathematics required to understand current research in PDEs, especially nonlinear PDEs. While he has reworked and simplified much of the classical theory (particularly the method of characteristics), he primarily emphasizes the modern interplay between funct...

  16. Optimization of partial search

    International Nuclear Information System (INIS)

    Korepin, Vladimir E

    2005-01-01

    A quantum Grover search algorithm can find a target item in a database faster than any classical algorithm. One can trade accuracy for speed and find a part of the database (a block) containing the target item even faster; this is partial search. A partial search algorithm was recently suggested by Grover and Radhakrishnan. Here we optimize it. Efficiency of the search algorithm is measured by the number of queries to the oracle. The author suggests a new version of the Grover-Radhakrishnan algorithm which uses a minimal number of such queries. The algorithm can run on the same hardware that is used for the usual Grover algorithm. (letter to the editor)

  17. PARTIAL REINFORCEMENT (ACQUISITION) EFFECTS WITHIN SUBJECTS.

    Science.gov (United States)

    AMSEL, A; MACKINNON, J R; RASHOTTE, M E; SURRIDGE, C T

    1964-03-01

    Acquisition performance of 22 rats in a straight alley runway was examined. The animals were subjected to partial reinforcement when the alley was black (B+/-) and continuous reinforcement when it was white (W+). The results indicated (a) higher terminal performance, for partial as against continuous reinforcement conditions, for starting-time and running-time measures, and (b) lower terminal performance under partial conditions for a goal-entry-time measure. These results confirm within subjects an effect previously demonstrated, in the runway, only in between-groups tests, where one group is run under partial reinforcement and a separate group is run under continuous reinforcement in the presence of the same external stimuli. Differences between the runway situation, employing a discrete-trial procedure and performance measures at three points in the response chain, and the Skinner box situation, used in its free-operant mode with a single performance measure, are discussed in relation to the present findings.

  18. Auxiliary partial liver transplantation

    NARCIS (Netherlands)

    C.B. Reuvers (Cornelis Bastiaan)

    1986-01-01

    textabstractIn this thesis studies on auxiliary partial liver transplantation in the dog and the pig are reported. The motive to perform this study was the fact that patients with acute hepatic failure or end-stage chronic liver disease are often considered to form too great a risk for successful

  19. Partial Remission Definition

    DEFF Research Database (Denmark)

    Andersen, Marie Louise Max; Hougaard, Philip; Pörksen, Sven

    2014-01-01

    OBJECTIVE: To validate the partial remission (PR) definition based on insulin dose-adjusted HbA1c (IDAA1c). SUBJECTS AND METHODS: The IDAA1c was developed using data in 251 children from the European Hvidoere cohort. For validation, 129 children from a Danish cohort were followed from the onset...

  20. Fundamental partial compositeness

    DEFF Research Database (Denmark)

    Sannino, Francesco; Strumia, Alessandro; Tesi, Andrea

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Unde...

  1. Partially ordered models

    NARCIS (Netherlands)

    Fernandez, R.; Deveaux, V.

    2010-01-01

    We provide a formal definition and study the basic properties of partially ordered chains (POC). These systems were proposed to model textures in image processing and to represent independence relations between random variables in statistics (in the later case they are known as Bayesian networks).

  2. Partially Hidden Markov Models

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Rissanen, Jorma

    1996-01-01

    Partially Hidden Markov Models (PHMM) are introduced. They differ from the ordinary HMM's in that both the transition probabilities of the hidden states and the output probabilities are conditioned on past observations. As an illustration they are applied to black and white image compression where...

  3. Honesty in partial logic

    NARCIS (Netherlands)

    W. van der Hoek (Wiebe); J.O.M. Jaspars; E. Thijsse

    1995-01-01

    textabstractWe propose an epistemic logic in which knowledge is fully introspective and implies truth, although truth need not imply epistemic possibility. The logic is presented in sequential format and is interpreted in a natural class of partial models, called balloon models. We examine the

  4. Algebraic partial Boolean algebras

    International Nuclear Information System (INIS)

    Smith, Derek

    2003-01-01

    Partial Boolean algebras, first studied by Kochen and Specker in the 1960s, provide the structure for Bell-Kochen-Specker theorems which deny the existence of non-contextual hidden variable theories. In this paper, we study partial Boolean algebras which are 'algebraic' in the sense that their elements have coordinates in an algebraic number field. Several of these algebras have been discussed recently in a debate on the validity of Bell-Kochen-Specker theorems in the context of finite precision measurements. The main result of this paper is that every algebraic finitely-generated partial Boolean algebra B(T) is finite when the underlying space H is three-dimensional, answering a question of Kochen and showing that Conway and Kochen's infinite algebraic partial Boolean algebra has minimum dimension. This result contrasts the existence of an infinite (non-algebraic) B(T) generated by eight elements in an abstract orthomodular lattice of height 3. We then initiate a study of higher-dimensional algebraic partial Boolean algebras. First, we describe a restriction on the determinants of the elements of B(T) that are generated by a given set T. We then show that when the generating set T consists of the rays spanning the minimal vectors in a real irreducible root lattice, B(T) is infinite just if that root lattice has an A 5 sublattice. Finally, we characterize the rays of B(T) when T consists of the rays spanning the minimal vectors of the root lattice E 8

  5. Efficient simultaneous partial nitrification, anammox and denitrification (SNAD) system equipped with a real-time dissolved oxygen (DO) intelligent control system and microbial community shifts of different substrate concentrations.

    Science.gov (United States)

    Wen, Xin; Gong, Benzhou; Zhou, Jian; He, Qiang; Qing, Xiaoxia

    2017-08-01

    Simultaneous partial nitrification, anammox and denitrification (SNAD) process was studied in a sequencing batch biofilm reactor (SBBR) fed with synthetic wastewater in a range of 2200 mgN/L ∼ 50 mgN/L. Important was an external real-time precision dissolved oxygen (DO) intelligent control system that consisted of feed forward control system and feedback control system. This DO control system permitted close control of oxygen supply according to influent concentration, effluent quality and other environmental factors in the reactor. In this study the operation was divided into six phases according to influent nitrogen applied. SNAD system was successfully set up after adding COD into a CANON system. And the presence of COD enabled the survival of denitrifiers, and made Thauera and Pseudomonas predominant as functional denitrifiers in this system. Denaturing gradient gel electrophoresis (DGGE), fluorescence in situ hybridization (FISH) and 16S rRNA amplicon pyrosequencing were used to analyze the microbial variations of different substrate concentrations. Results indicated that the relative population of ammonia oxidizing bacteria (AOB) members decreased when influent ammonia concentration decreased from 2200 mg/L to 50 mg/L, while no dramatic drop of the percent of anammox bacteria was seen. And Nitrosomonas europaea was the predominant AOB in SNAD system treating sewage, while Candidatus Brocadia was the dominant anammox bacteria. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Partially composite Higgs models

    DEFF Research Database (Denmark)

    Alanne, Tommi; Buarque Franzosi, Diogo; Frandsen, Mads T.

    2018-01-01

    We study the phenomenology of partially composite-Higgs models where electroweak symmetry breaking is dynamically induced, and the Higgs is a mixture of a composite and an elementary state. The models considered have explicit realizations in terms of gauge-Yukawa theories with new strongly...... interacting fermions coupled to elementary scalars and allow for a very SM-like Higgs state. We study constraints on their parameter spaces from vacuum stability and perturbativity as well as from LHC results and find that requiring vacuum stability up to the compositeness scale already imposes relevant...... constraints. A small part of parameter space around the classically conformal limit is stable up to the Planck scale. This is however already strongly disfavored by LHC results. in different limits, the models realize both (partially) composite-Higgs and (bosonic) technicolor models and a dynamical extension...

  7. Thin film devices used as oxygen partial pressure sensors

    Science.gov (United States)

    Canady, K. S.; Wortman, J. J.

    1970-01-01

    Electrical conductivity of zinc oxide films to be used in an oxygen partial pressure sensor is measured as a function of temperature, oxygen partial pressure, and other atmospheric constituents. Time response following partial pressure changes is studied as a function of temperature and environmental changes.

  8. Photogenic partial seizures.

    Science.gov (United States)

    Hennessy, M J; Binnie, C D

    2000-01-01

    To establish the incidence and symptoms of partial seizures in a cohort of patients investigated on account of known sensitivity to intermittent photic stimulation and/or precipitation of seizures by environmental visual stimuli such as television (TV) screens or computer monitors. We report 43 consecutive patients with epilepsy, who had exhibited a significant EEG photoparoxysmal response or who had seizures precipitated by environmental visual stimuli and underwent detailed assessment of their photosensitivity in the EEG laboratory, during which all were questioned concerning their ictal symptoms. All patients were considered on clinical grounds to have an idiopathic epilepsy syndrome. Twenty-eight (65%) patients reported visually precipitated attacks occurring initially with maintained consciousness, in some instances evolving to a period of confusion or to a secondarily generalized seizure. Visual symptoms were most commonly reported and included positive symptoms such as coloured circles or spots, but also blindness and subjective symptoms such as "eyes going funny." Other symptoms described included nonspecific cephalic sensations, deja-vu, auditory hallucinations, nausea, and vomiting. No patient reported any clear spontaneous partial seizures, and there were no grounds for supposing that any had partial epilepsy excepting the ictal phenomenology of some or all of the visually induced attacks. These findings provide clinical support for the physiological studies that indicate that the trigger mechanism for human photosensitivity involves binocularly innervated cells located in the visual cortex. Thus the visual cortex is the seat of the primary epileptogenic process, and the photically triggered discharges and seizures may be regarded as partial with secondary generalization.

  9. Arthroscopic partial medial meniscectomy

    Directory of Open Access Journals (Sweden)

    Dašić Žarko

    2011-01-01

    Full Text Available Background/Aim. Meniscal injuries are common in professional or recreational sports as well as in daily activities. If meniscal lesions lead to physical impairment they usually require surgical treatment. Arthroscopic treatment of meniscal injuries is one of the most often performed orthopedic operative procedures. Methods. The study analyzed the results of arthroscopic partial medial meniscectomy in 213 patients in a 24-month period, from 2006, to 2008. Results. In our series of arthroscopically treated medial meniscus tears we noted 78 (36.62% vertical complete bucket handle lesions, 19 (8.92% vertical incomplete lesions, 18 (8.45% longitudinal tears, 35 (16.43% oblique tears, 18 (8.45% complex degenerative lesions, 17 (7.98% radial lesions and 28 (13.14% horisontal lesions. Mean preoperative International Knee Documentation Committee (IKDC score was 49.81%, 1 month after the arthroscopic partial medial meniscectomy the mean IKDC score was 84.08%, and 6 months after mean IKDC score was 90.36%. Six months after the procedure 197 (92.49% of patients had good or excellent subjective postoperative clinical outcomes, while 14 (6.57% patients subjectively did not notice a significant improvement after the intervention, and 2 (0.93% patients had no subjective improvement after the partial medial meniscectomy at all. Conclusion. Arthroscopic partial medial meniscetomy is minimally invasive diagnostic and therapeutic procedure and in well selected cases is a method of choice for treatment of medial meniscus injuries when repair techniques are not a viable option. It has small rate of complications, low morbidity and fast rehabilitation.

  10. Hierarchical partial order ranking

    International Nuclear Information System (INIS)

    Carlsen, Lars

    2008-01-01

    Assessing the potential impact on environmental and human health from the production and use of chemicals or from polluted sites involves a multi-criteria evaluation scheme. A priori several parameters are to address, e.g., production tonnage, specific release scenarios, geographical and site-specific factors in addition to various substance dependent parameters. Further socio-economic factors may be taken into consideration. The number of parameters to be included may well appear to be prohibitive for developing a sensible model. The study introduces hierarchical partial order ranking (HPOR) that remedies this problem. By HPOR the original parameters are initially grouped based on their mutual connection and a set of meta-descriptors is derived representing the ranking corresponding to the single groups of descriptors, respectively. A second partial order ranking is carried out based on the meta-descriptors, the final ranking being disclosed though average ranks. An illustrative example on the prioritisation of polluted sites is given. - Hierarchical partial order ranking of polluted sites has been developed for prioritization based on a large number of parameters

  11. In vivo bleeding time and in vitro thrombelastography measurements are better indicators of dilutional hypothermic coagulopathy than prothrombin time.

    Science.gov (United States)

    Kheirabadi, Bijan S; Crissey, Jacqueline M; Deguzman, Rodolfo; Holcomb, John B

    2007-06-01

    The coagulopathy of trauma is generally confirmed by prothrombin time (PT) > or =16 seconds or an international normalized ratio > or =1.5. However, the utility of these values as a screening test is unknown. We examined different coagulation tests to determine the best predictor of coagulopathic bleeding and mortality in a small animal hemorrhage model. Coagulopathy was induced in male New Zealand White rabbits by warfarin (W; 2 mg/kg for 2 days; n = 7), or hemodilution and hypothermia (HH; 50% blood exchange with Hextend, 34.5 +/- 0.3 degrees C; n = 7). Normal (N) rabbits without pretreatment served as the control (n = 7). Blood samples collected after coagulopathy induction and analyzed by prothrombin time (PT), activated partial thromboplastin time (aPTT), and thromboelastography (TEG) tests. Liver bleeding time (BT) was also measured before injury. An uncontrolled hemorrhage was created by a longitudinal splenic incision and the abdomen was closed. Rabbits were resuscitated with Hextend solution (25 mL/kg) to return blood pressure to baseline and monitored for 2 hours or until death at which time blood loss was measured. Warfarin-induced coagulopathy increased BT, PT, and aPTT. TEG showed increased reaction (R) and clot formation (K) times and marked decrease in clotting rate (alpha angle and Vmax). Hemodilution hypothermia coagulopathy increased only BT and aPTT, and decreased the clotting rate (alpha angle and Vmax) and strength of the clot. After injury, blood losses were higher in coagulopathic rabbits (W = 54.6 +/- 4.2 and HH = 51.1 +/- 8.9 mL/kg) than in normal rabbits (30.6 +/- 12.4 mL/kg) and resulted in 86%, 100%, and 0% death, respectively. BT and Vmax consistently predicted coagulopathic bleeding and death in all animals. Although satisfactory in warfarin-induced coagulopathy, PT was not a valid screening test for dilutional and hypothermic coagulopathy. BT and TEG measurements of blood clotting rate are better indicators of coagulopathic bleeding

  12. Correlation of rocket propulsion fuel properties with chemical composition using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry followed by partial least squares regression analysis.

    Science.gov (United States)

    Kehimkar, Benjamin; Hoggard, Jamin C; Marney, Luke C; Billingsley, Matthew C; Fraga, Carlos G; Bruno, Thomas J; Synovec, Robert E

    2014-01-31

    There is an increased need to more fully assess and control the composition of kerosene-based rocket propulsion fuels such as RP-1. In particular, it is critical to make better quantitative connections among the following three attributes: fuel performance (thermal stability, sooting propensity, engine specific impulse, etc.), fuel properties (such as flash point, density, kinematic viscosity, net heat of combustion, and hydrogen content), and the chemical composition of a given fuel, i.e., amounts of specific chemical compounds and compound classes present in a fuel as a result of feedstock blending and/or processing. Recent efforts in predicting fuel chemical and physical behavior through modeling put greater emphasis on attaining detailed and accurate fuel properties and fuel composition information. Often, one-dimensional gas chromatography (GC) combined with mass spectrometry (MS) is employed to provide chemical composition information. Building on approaches that used GC-MS, but to glean substantially more chemical information from these complex fuels, we recently studied the use of comprehensive two dimensional (2D) gas chromatography combined with time-of-flight mass spectrometry (GC×GC-TOFMS) using a "reversed column" format: RTX-wax column for the first dimension, and a RTX-1 column for the second dimension. In this report, by applying chemometric data analysis, specifically partial least-squares (PLS) regression analysis, we are able to readily model (and correlate) the chemical compositional information provided by use of GC×GC-TOFMS to RP-1 fuel property information such as density, kinematic viscosity, net heat of combustion, and so on. Furthermore, we readily identified compounds that contribute significantly to measured differences in fuel properties based on results from the PLS models. We anticipate this new chemical analysis strategy will have broad implications for the development of high fidelity composition-property models, leading to an

  13. Measurement of alveolar oxygen partial pressure in the rat lung using Carr-Purcell-Meiboom-Gill spin-spin relaxation times of hyperpolarized 3He and 129Xe at 74 mT.

    Science.gov (United States)

    Kraayvanger, Ryan J; Bidinosti, Christopher P; Dominguez-Viqueira, William; Parra-Robles, Juan; Fox, Matthew; Lam, Wilfred W; Santyr, Giles E

    2010-11-01

    Regional measurement of alveolar oxygen partial pressure can be obtained from the relaxation rates of hyperpolarized noble gases, (3) He and (129) Xe, in the lungs. Recently, it has been demonstrated that measurements of alveolar oxygen partial pressure can be obtained using the spin-spin relaxation rate (R(2) ) of (3) He at low magnetic field strengths (oxygen partial pressure measurements based on Carr-Purcell-Meiboom-Gill R(2) values of hyperpolarized (3) He and (129) Xe in vitro and in vivo in the rat lung at low magnetic field strength (74 mT) are presented. In vitro spin-spin relaxivity constants for (3) He and (129) Xe were determined to be (5.2 ± 0.6) × 10(-6) Pa(-1) sec(-1) and (7.3 ± 0.4) × 10(-6) Pa(-1) s(-1) compared with spin-lattice relaxivity constants of (4.0 ± 0.4) × 10(-6) Pa(-1) s(-1) and (4.3 ± 1.3) × 10(-6) Pa(-1) s(-1), respectively. In vivo experimental measurements of alveolar oxygen partial pressure using (3) He in whole rat lung show good agreement (r(2) = 0.973) with predictions based on lung volumes and ventilation parameters. For (129) Xe, multicomponent relaxation was observed with one component exhibiting an increase in R(2) with decreasing alveolar oxygen partial pressure. Copyright © 2010 Wiley-Liss, Inc.

  14. Partially ordered algebraic systems

    CERN Document Server

    Fuchs, Laszlo

    2011-01-01

    Originally published in an important series of books on pure and applied mathematics, this monograph by a distinguished mathematician explores a high-level area in algebra. It constitutes the first systematic summary of research concerning partially ordered groups, semigroups, rings, and fields. The self-contained treatment features numerous problems, complete proofs, a detailed bibliography, and indexes. It presumes some knowledge of abstract algebra, providing necessary background and references where appropriate. This inexpensive edition of a hard-to-find systematic survey will fill a gap i

  15. Infinite partial summations

    International Nuclear Information System (INIS)

    Sprung, D.W.L.

    1975-01-01

    This paper is a brief review of those aspects of the effective interaction problem that can be grouped under the heading of infinite partial summations of the perturbation series. After a brief mention of the classic examples of infinite summations, the author turns to the effective interaction problem for two extra core particles. Their direct interaction is summed to produce the G matrix, while their indirect interaction through the core is summed in a variety of ways under the heading of core polarization. (orig./WL) [de

  16. On universal partial words

    OpenAIRE

    Chen, Herman Z. Q.; Kitaev, Sergey; Mütze, Torsten; Sun, Brian Y.

    2016-01-01

    A universal word for a finite alphabet $A$ and some integer $n\\geq 1$ is a word over $A$ such that every word in $A^n$ appears exactly once as a subword (cyclically or linearly). It is well-known and easy to prove that universal words exist for any $A$ and $n$. In this work we initiate the systematic study of universal partial words. These are words that in addition to the letters from $A$ may contain an arbitrary number of occurrences of a special `joker' symbol $\\Diamond\

  17. Partial differential equations

    CERN Document Server

    Agranovich, M S

    2002-01-01

    Mark Vishik's Partial Differential Equations seminar held at Moscow State University was one of the world's leading seminars in PDEs for over 40 years. This book celebrates Vishik's eightieth birthday. It comprises new results and survey papers written by many renowned specialists who actively participated over the years in Vishik's seminars. Contributions include original developments and methods in PDEs and related fields, such as mathematical physics, tomography, and symplectic geometry. Papers discuss linear and nonlinear equations, particularly linear elliptic problems in angles and gener

  18. Partial differential equations

    CERN Document Server

    Levine, Harold

    1997-01-01

    The subject matter, partial differential equations (PDEs), has a long history (dating from the 18th century) and an active contemporary phase. An early phase (with a separate focus on taut string vibrations and heat flow through solid bodies) stimulated developments of great importance for mathematical analysis, such as a wider concept of functions and integration and the existence of trigonometric or Fourier series representations. The direct relevance of PDEs to all manner of mathematical, physical and technical problems continues. This book presents a reasonably broad introductory account of the subject, with due regard for analytical detail, applications and historical matters.

  19. Partial differential equations

    CERN Document Server

    Sloan, D; Süli, E

    2001-01-01

    /homepage/sac/cam/na2000/index.html7-Volume Set now available at special set price ! Over the second half of the 20th century the subject area loosely referred to as numerical analysis of partial differential equations (PDEs) has undergone unprecedented development. At its practical end, the vigorous growth and steady diversification of the field were stimulated by the demand for accurate and reliable tools for computational modelling in physical sciences and engineering, and by the rapid development of computer hardware and architecture. At the more theoretical end, the analytical insight in

  20. Elliptic partial differential equations

    CERN Document Server

    Han, Qing

    2011-01-01

    Elliptic Partial Differential Equations by Qing Han and FangHua Lin is one of the best textbooks I know. It is the perfect introduction to PDE. In 150 pages or so it covers an amazing amount of wonderful and extraordinary useful material. I have used it as a textbook at both graduate and undergraduate levels which is possible since it only requires very little background material yet it covers an enormous amount of material. In my opinion it is a must read for all interested in analysis and geometry, and for all of my own PhD students it is indeed just that. I cannot say enough good things abo

  1. Generalized Partial Volume

    DEFF Research Database (Denmark)

    Darkner, Sune; Sporring, Jon

    2011-01-01

    Mutual Information (MI) and normalized mutual information (NMI) are popular choices as similarity measure for multimodal image registration. Presently, one of two approaches is often used for estimating these measures: The Parzen Window (PW) and the Generalized Partial Volume (GPV). Their theoret...... of view as well as w.r.t. computational complexity. Finally, we present algorithms for both approaches for NMI which is comparable in speed to Sum of Squared Differences (SSD), and we illustrate the differences between PW and GPV on a number of registration examples....

  2. Partially coherent isodiffracting pulsed beams

    Science.gov (United States)

    Koivurova, Matias; Ding, Chaoliang; Turunen, Jari; Pan, Liuzhan

    2018-02-01

    We investigate a class of isodiffracting pulsed beams, which are superpositions of transverse modes supported by spherical-mirror laser resonators. By employing modal weights that, for stationary light, produce a Gaussian Schell-model beam, we extend this standard model to pulsed beams. We first construct the two-frequency cross-spectral density function that characterizes the spatial coherence in the space-frequency domain. By assuming a power-exponential spectral profile, we then employ the generalized Wiener-Khintchine theorem for nonstationary light to derive the two-time mutual coherence function that describes the space-time coherence of the ensuing beams. The isodiffracting nature of the laser resonator modes permits all (paraxial-domain) calculations at any propagation distance to be performed analytically. Significant spatiotemporal coupling is revealed in subcycle, single-cycle, and few-cycle domains, where the partial spatial coherence also leads to reduced temporal coherence even though full spectral coherence is assumed.

  3. Unilateral removable partial dentures.

    Science.gov (United States)

    Goodall, W A; Greer, A C; Martin, N

    2017-01-27

    Removable partial dentures (RPDs) are widely used to replace missing teeth in order to restore both function and aesthetics for the partially dentate patient. Conventional RPD design is frequently bilateral and consists of a major connector that bridges both sides of the arch. Some patients cannot and will not tolerate such an extensive appliance. For these patients, bridgework may not be a predictable option and it is not always possible to provide implant-retained restorations. This article presents unilateral RPDs as a potential treatment modality for such patients and explores indications and contraindications for their use, including factors relating to patient history, clinical presentation and patient wishes. Through case examples, design, material and fabrication considerations will be discussed. While their use is not widespread, there are a number of patients who benefit from the provision of unilateral RPDs. They are a useful treatment to have in the clinician's armamentarium, but a highly-skilled dental team and a specific patient presentation is required in order for them to be a reasonable and predictable prosthetic option.

  4. Tutorial on Online Partial Evaluation

    Directory of Open Access Journals (Sweden)

    William R. Cook

    2011-09-01

    Full Text Available This paper is a short tutorial introduction to online partial evaluation. We show how to write a simple online partial evaluator for a simple, pure, first-order, functional programming language. In particular, we show that the partial evaluator can be derived as a variation on a compositionally defined interpreter. We demonstrate the use of the resulting partial evaluator for program optimization in the context of model-driven development.

  5. Complex partial seizures: cerebellar metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Theodore, W.H.; Fishbein, D.; Deitz, M.; Baldwin, P.

    1987-07-01

    We used positron emission tomography (PET) with (/sup 18/F)2-deoxyglucose to study cerebellar glucose metabolism (LCMRglu) and the effect of phenytoin (PHT) in 42 patients with complex partial seizures (CPS), and 12 normal controls. Mean +/- SD patient LCMRglu was 6.9 +/- 1.8 mg glucose/100 g/min (left = right), significantly lower than control values of 8.5 +/- 1.8 (left, p less than 0.006), and 8.3 +/- 1.6 (right, p less than 0.02). Only four patients had cerebellar atrophy on CT/MRI; cerebellar LCMRglu in these was 5.5 +/- 1.5 (p = 0.054 vs. total patient sample). Patients with unilateral temporal hypometabolism or EEG foci did not have lateralized cerebellar hypometabolism. Patients receiving phenytoin (PHT) at the time of scan and patients with less than 5 years total PHT exposure had lower LCMRglu, but the differences were not significant. There were weak inverse correlations between PHT level and cerebellar LCMRglu in patients receiving PHT (r = -0.36; 0.05 less than p less than 0.1), as well as between length of illness and LCMRglu (r = -0.22; 0.05 less than p less than 0.1). Patients with complex partial seizures have cerebellar hypometabolism that is bilateral and due only in part to the effect of PHT.

  6. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML...

  7. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML of ...

  8. Monitoring of unfractionated heparin with rotational thrombelastometry using the prothrombinase-induced clotting time reagent (PiCT®).

    Science.gov (United States)

    Schaden, E; Jilch, S; Hacker, S; Schober, A; Kozek-Langenecker, S

    2012-12-24

    To achieve sufficient and safe anticoagulation with unfractionated heparin (UFH) a close and reliable drug monitoring is necessary. In general, the activated partial thromboplastin time (APTT) is used for this purpose. In acute phase response, however, the APTT test procedure might be unreliable e.g. with false low results in the presence of elevated factor VIII. In this so called heparin resistance, measurement of anti-Xa activity is recommended over APTT to avoid potentially harmful dose escalation. A combination of anti-Xa measurement and global hemostatic testing with ROTEM® employing the anti-Xa sensitive PiCT® reagent showed high correlation with enoxaparin levels. This test modification could also be suitable for monitoring UFH. Aim of the study was to evaluate the correlation between PiCT®-ROTEM® and levels of UFH. In this in-vitro study blood samples from healthy volunteers were spiked with UFH and subjected to different ROTEM® tests. There was a linear correlation between UFH level and clotting time (CT) in the PiCT®-ROTEM® test with an excellent correlation coefficient of 0.92. Additional endpoints showed similar results (PiCT®-ROTEM® MaxVel r = -0.85 and PiCT®-ROTEM® t_MaxVel r = 0.88). As a point-of-care applicable tool ROTEM® is immediately at hand. If further clinical studies confirm sensitivity in heparin resistance, PiCT®-ROTEM® could permit rapid UFH dose adjustments especially required in critical illness with acute phase response. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Applied partial differential equations

    CERN Document Server

    Logan, J David

    2004-01-01

    This primer on elementary partial differential equations presents the standard material usually covered in a one-semester, undergraduate course on boundary value problems and PDEs. What makes this book unique is that it is a brief treatment, yet it covers all the major ideas: the wave equation, the diffusion equation, the Laplace equation, and the advection equation on bounded and unbounded domains. Methods include eigenfunction expansions, integral transforms, and characteristics. Mathematical ideas are motivated from physical problems, and the exposition is presented in a concise style accessible to science and engineering students; emphasis is on motivation, concepts, methods, and interpretation, rather than formal theory. This second edition contains new and additional exercises, and it includes a new chapter on the applications of PDEs to biology: age structured models, pattern formation; epidemic wave fronts, and advection-diffusion processes. The student who reads through this book and solves many of t...

  10. Inductance loop and partial

    CERN Document Server

    Paul, Clayton R

    2010-01-01

    "Inductance is an unprecedented text, thoroughly discussing "loop" inductance as well as the increasingly important "partial" inductance. These concepts and their proper calculation are crucial in designing modern high-speed digital systems. World-renowned leader in electromagnetics Clayton Paul provides the knowledge and tools necessary to understand and calculate inductance." "With the present and increasing emphasis on high-speed digital systems and high-frequency analog systems, it is imperative that system designers develop an intimate understanding of the concepts and methods in this book. Inductance is a much-needed textbook designed for senior and graduate-level engineering students, as well as a hands-on guide for working engineers and professionals engaged in the design of high-speed digital and high-frequency analog systems."--Jacket.

  11. Fundamental partial compositeness

    CERN Document Server

    Sannino, Francesco

    2016-11-07

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough 'square root'. Furthermore, right-handed SM fermions have an SU(2)$_R$-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  12. Fundamental partial compositeness

    International Nuclear Information System (INIS)

    Sannino, Francesco; Strumia, Alessandro; Tesi, Andrea; Vigiani, Elena

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Under certain assumptions on the dynamics of the scalars, successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough ‘square root’. Furthermore, right-handed SM fermions have an SU(2)_R-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  13. Partial oxidation process

    International Nuclear Information System (INIS)

    Najjar, M.S.

    1987-01-01

    A process is described for the production of gaseous mixtures comprising H/sub 2/+CO by the partial oxidation of a fuel feedstock comprising a heavy liquid hydrocarbonaceous fuel having a nickel, iron, and vanadium-containing ash or petroleum coke having a nickel, iron, and vanadium-containing ash, or mixtures thereof. The feedstock includes a minimum of 0.5 wt. % of sulfur and the ash includes a minimum of 5.0 wt. % vanadium, a minimum of 0.5 ppm nickel, and a minimum of 0.5 ppm iron. The process comprises: (1) mixing together a copper-containing additive with the fuel feedstock; wherein the weight ratio of copper-containing additive to ash in the fuel feedstock is in the range of about 1.0-10.0, and there is at least 10 parts by weight of copper for each part by weight of vanadium; (2) reacting the mixture from (1) at a temperature in the range of 2200 0 F to 2900 0 F and a pressure in the range of about 5 to 250 atmospheres in a free-flow refactory lined partial oxidation reaction zone with a free-oxygen containing gas in the presence of a temperature moderator and in a reducing atmosphere to produce a hot raw effluent gas stream comprising H/sub 2/+CO and entrained molten slag; and where in the reaction zone and the copper-containing additive combines with at least a portion of the nickel and iron constituents and sulfur found in the feedstock to produce a liquid phase washing agent that collects and transports at least a portion of the vanadium-containing oxide laths and spinels and other ash components and refractory out of the reaction zone; and (3) separating nongaseous materials from the hot raw effluent gas stream

  14. A computational formalization for partial evaluation

    DEFF Research Database (Denmark)

    Hatcliff, John; Danvy, Olivier

    1996-01-01

    We formalize a partial evaluator for Eugenio Moggi's computational metalanguage. This formalization gives an evaluation-order independent view of binding-time analysis and program specialization, including a proper treatment of call unfolding. It also enables us to express the essence of `control......-based binding-time improvements' for let expressions. Specically, we prove that the binding-time improvements given by `continuation-based specialization' can be expressed in the metalanguage via monadic laws....

  15. Fast Partial Evaluation of Pattern Matching in Strings

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Rohde, Henning Korsholm

    2003-01-01

    We show how to obtain all of Knuth, Morris, and Pratt's linear-time string matcher by partial evaluation of a quadratic-time string matcher with respect to a pattern string. Although it has been known for 15 years how to obtain this linear matcher by partial evaluation of a quadratic one, how...... to obtain it in linear time has remained an open problem.Obtaining a linear matcher by partial evaluation of a quadratic one is achieved by performing its backtracking at specialization time and memoizing its results. We show (1) how to rewrite the source matcher such that its static intermediate...... computations can be shared at specialization time and (2) how to extend the memoization capabilities of a partial evaluator to static functions. Such an extended partial evaluator, if its memoization is implemented efficiently, specializes the rewritten source matcher in linear time....

  16. Experts' understanding of partial derivatives using the Partial Derivative Machine

    OpenAIRE

    Roundy, David; Dorko, Allison; Dray, Tevian; Manogue, Corinne A.; Weber, Eric

    2014-01-01

    Partial derivatives are used in a variety of different ways within physics. Most notably, thermodynamics uses partial derivatives in ways that students often find confusing. As part of a collaboration with mathematics faculty, we are at the beginning of a study of the teaching of partial derivatives, a goal of better aligning the teaching of multivariable calculus with the needs of students in STEM disciplines. As a part of this project, we have performed a pilot study of expert understanding...

  17. Flow visualization via partial differential equations

    NARCIS (Netherlands)

    Preusser, T.; Rumpf, M.; Telea, A.C.; Möller, T.; Hamann, B.; Russell, R.D.

    2009-01-01

    The visualization of stationary and time-dependent flow is an important and chaltenging topic in scientific visualization. lts aim is 10 represent transport phenomena govemed by vector fjelds in an intuitively understandable way. In this paper. we review the use of methods based on partial

  18. A computational formalization for partial evaluation

    DEFF Research Database (Denmark)

    Hatcliff, John; Danvy, Olivier

    1997-01-01

    We formalize a partial evaluator for Eugenio Moggi's computational metalanguage. This formalization gives an evaluation-order independent view of binding-time analysis and program specialization, including a proper treatment of call unfolding. It also enables us to express the essence of `control...

  19. Comparison of growth on mannitol salt agar, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, VITEK® 2 with partial sequencing of 16S rRNA gene for identification of coagulase-negative staphylococci.

    Science.gov (United States)

    Ayeni, Funmilola A; Andersen, Camilla; Nørskov-Lauritsen, Niels

    2017-04-01

    Mannitol salt agar (MSA) is often used in resources' limited laboratories for identification of S. aureus however, coagulase-negative staphylococci (CoNS) grows and ferments mannitol on MSA. 171 strains of CoNS which have been previously misidentified as S. aureus due to growth on MSA were collected from different locations in Nigeria and two methods for identification of CoNS were compared i.e. ViTEK 2 and MALDI-TOF MS with partial 16S rRNA gene sequencing as gold standard. Partial tuf gene sequencing was used for contradicting identification. All 171 strains (13 species) grew on MSA and ferments mannitol. All tested strains of S. epidermidis, S. haemolyticus, S. nepalensis, S. pasteuri, S. sciuri,, S. warneri, S. xylosus, S. capitis were correctly identified by MALDI-TOF while variable identification were observed in S. saprophyticus and S. cohnii (90%, 81%). There was low identification of S. arlettae (14%) while all strains of S. kloosii and S. gallinarum were misidentified. There is absence of S. gallinarum in the MALDI-TOF database at the period of this study. All tested strains of S. epidermidis, S. gallinarum, S. haemolyticus, S. sciuri,, S. warneri, S. xylosus and S. capitis were correctly identified by ViTEK while variable identification were observed in S. saprophyticus, S. arlettae, S. cohnii, S. kloosii, (84%, 86%, 75%, 60%) and misidentification of S. nepalensis, S. pasteuri. Partial sequencing of 16S rRNA gene was used as gold standard for most strains except S. capitis and S. xylosus where the two species were misidentified by partial sequencing of 16S rRNA contrary to MALDI-TOF and ViTEK identification. Tuf gene sequencing was used for correct identification. Characteristic growth on MSA for CoNS is also identical to S. aureus growth on the media and therefore, MSA could not differentiate between S. aureus and CoNS. The percentage accuracy of ViTEK was better than MALDI-TOF in identification of CoNS. Although partial sequencing of

  20. Partial Actions and Power Sets

    Directory of Open Access Journals (Sweden)

    Jesús Ávila

    2013-01-01

    Full Text Available We consider a partial action (X,α with enveloping action (T,β. In this work we extend α to a partial action on the ring (P(X,Δ,∩ and find its enveloping action (E,β. Finally, we introduce the concept of partial action of finite type to investigate the relationship between (E,β and (P(T,β.

  1. Algorithms over partially ordered sets

    DEFF Research Database (Denmark)

    Baer, Robert M.; Østerby, Ole

    1969-01-01

    in partially ordered sets, answer the combinatorial question of how many maximal chains might exist in a partially ordered set withn elements, and we give an algorithm for enumerating all maximal chains. We give (in § 3) algorithms which decide whether a partially ordered set is a (lower or upper) semi......-lattice, and whether a lattice has distributive, modular, and Boolean properties. Finally (in § 4) we give Algol realizations of the various algorithms....

  2. Partial order infinitary term rewriting

    DEFF Research Database (Denmark)

    Bahr, Patrick

    2014-01-01

    We study an alternative model of infinitary term rewriting. Instead of a metric on terms, a partial order on partial terms is employed to formalise convergence of reductions. We consider both a weak and a strong notion of convergence and show that the metric model of convergence coincides with th...... to the metric setting -- orthogonal systems are both infinitarily confluent and infinitarily normalising in the partial order setting. The unique infinitary normal forms that the partial order model admits are Böhm trees....

  3. How to test for partially predictable chaos.

    Science.gov (United States)

    Wernecke, Hendrik; Sándor, Bulcsú; Gros, Claudius

    2017-04-24

    For a chaotic system pairs of initially close-by trajectories become eventually fully uncorrelated on the attracting set. This process of decorrelation can split into an initial exponential decrease and a subsequent diffusive process on the chaotic attractor causing the final loss of predictability. Both processes can be either of the same or of very different time scales. In the latter case the two trajectories linger within a finite but small distance (with respect to the overall extent of the attractor) for exceedingly long times and remain partially predictable. Standard tests for chaos widely use inter-orbital correlations as an indicator. However, testing partially predictable chaos yields mostly ambiguous results, as this type of chaos is characterized by attractors of fractally broadened braids. For a resolution we introduce a novel 0-1 indicator for chaos based on the cross-distance scaling of pairs of initially close trajectories. This test robustly discriminates chaos, including partially predictable chaos, from laminar flow. Additionally using the finite time cross-correlation of pairs of initially close trajectories, we are able to identify laminar flow as well as strong and partially predictable chaos in a 0-1 manner solely from the properties of pairs of trajectories.

  4. Partial androgen insensitivity syndrome

    Science.gov (United States)

    ... being on the underside of the penis, small penis, small scrotum (with a line down the middle or incompletely closed), or undescended testicles . Breast development in males at time of puberty. Decreased body hair and beard, but normal pubic ...

  5. On the relation between elementary partial difference equations and partial differential equations

    NARCIS (Netherlands)

    van den Berg, I.P.

    1998-01-01

    The nonstandard stroboscopy method links discrete-time ordinary difference equations of first-order and continuous-time, ordinary differential equations of first order. We extend this method to the second order, and also to an elementary, yet general class of partial difference/differential

  6. Reasoning about Strategies under Partial Observability and Fairness Constraints

    Directory of Open Access Journals (Sweden)

    Simon Busard

    2013-03-01

    Full Text Available A number of extensions exist for Alternating-time Temporal Logic; some of these mix strategies and partial observability but, to the best of our knowledge, no work provides a unified framework for strategies, partial observability and fairness constraints. In this paper we propose ATLK^F_po, a logic mixing strategies under partial observability and epistemic properties of agents in a system with fairness constraints on states, and we provide a model checking algorithm for it.

  7. Elevated prothrombin time on routine preoperative laboratory results in a healthy infant undergoing craniosynostosis repair: Diagnosis and perioperative management of congenital factor VII deficiency.

    Science.gov (United States)

    Jones, Kareen L; Greenberg, Robert S; Ahn, Edward S; Kudchadkar, Sapna R

    2016-01-01

    Congenital factor VII deficiency is a rare bleeding disorder with high phenotypic variability. It is critical that children with congenital Factor VII deficiency be identified early when high-risk surgery is planned. Cranial vault surgery is common for children with craniosynostosis, and these surgeries are associated with significant morbidity mostly secondary to the risk of massive blood loss. A two-month old infant who presented for elective craniosynostosis repair was noted to have an elevated prothrombin time (PT) with a normal activated partial thromboplastin time (aPTT) on preoperative labs. The infant had no clinical history or reported family history of bleeding disorders, therefore a multidisciplinary decision was made to repeat the labs under general anesthesia and await the results prior to incision. The results confirmed the abnormal PT and the case was canceled. Hematologic workup during admission revealed factor VII deficiency. The patient underwent an uneventful endoscopic strip craniectomy with perioperative administration of recombinant Factor VIIa. Important considerations for perioperative laboratory evaluation and management in children with factor VII deficiency are discussed. Anesthetic and surgical management of the child with factor VII deficiency necessitates meticulous planning to prevent life threatening bleeding during the perioperative period. A thorough history and physical examination with a high clinical suspicion are vital in preventing hemorrhage during surgeries in children with coagulopathies. Abnormal preoperative lab values should always be confirmed and addressed before proceeding with high-risk surgery. A multidisciplinary discussion is essential to optimize the risk-benefit ratio during the perioperative period. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. On Degenerate Partial Differential Equations

    OpenAIRE

    Chen, Gui-Qiang G.

    2010-01-01

    Some of recent developments, including recent results, ideas, techniques, and approaches, in the study of degenerate partial differential equations are surveyed and analyzed. Several examples of nonlinear degenerate, even mixed, partial differential equations, are presented, which arise naturally in some longstanding, fundamental problems in fluid mechanics and differential geometry. The solution to these fundamental problems greatly requires a deep understanding of nonlinear degenerate parti...

  9. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  10. Partial Epilepsy with Auditory Features

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2004-07-01

    Full Text Available The clinical characteristics of 53 sporadic (S cases of idiopathic partial epilepsy with auditory features (IPEAF were analyzed and compared to previously reported familial (F cases of autosomal dominant partial epilepsy with auditory features (ADPEAF in a study at the University of Bologna, Italy.

  11. Partial twisting for scalar mesons

    International Nuclear Information System (INIS)

    Agadjanov, Dimitri; Meißner, Ulf-G.; Rusetsky, Akaki

    2014-01-01

    The possibility of imposing partially twisted boundary conditions is investigated for the scalar sector of lattice QCD. According to the commonly shared belief, the presence of quark-antiquark annihilation diagrams in the intermediate state generally hinders the use of the partial twisting. Using effective field theory techniques in a finite volume, and studying the scalar sector of QCD with total isospin I=1, we however demonstrate that partial twisting can still be performed, despite the fact that annihilation diagrams are present. The reason for this are delicate cancellations, which emerge due to the graded symmetry in partially quenched QCD with valence, sea and ghost quarks. The modified Lüscher equation in case of partial twisting is given

  12. Diffraction through partial identity

    International Nuclear Information System (INIS)

    Blum, W.

    1981-06-01

    A model of diffraction dissociation is proposed in which the quantum-mechanical interference between the incoming and the outgoing wave determines the cross-section. This interference occurs due to the finite life-time of the excited state. (orig.)

  13. Partial wave analysis using graphics processing units

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Niklaus; Liu Beijiang; Wang Jike, E-mail: nberger@ihep.ac.c [Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Lu, Shijingshan, 100049 Beijing (China)

    2010-04-01

    Partial wave analysis is an important tool for determining resonance properties in hadron spectroscopy. For large data samples however, the un-binned likelihood fits employed are computationally very expensive. At the Beijing Spectrometer (BES) III experiment, an increase in statistics compared to earlier experiments of up to two orders of magnitude is expected. In order to allow for a timely analysis of these datasets, additional computing power with short turnover times has to be made available. It turns out that graphics processing units (GPUs) originally developed for 3D computer games have an architecture of massively parallel single instruction multiple data floating point units that is almost ideally suited for the algorithms employed in partial wave analysis. We have implemented a framework for tensor manipulation and partial wave fits called GPUPWA. The user writes a program in pure C++ whilst the GPUPWA classes handle computations on the GPU, memory transfers, caching and other technical details. In conjunction with a recent graphics processor, the framework provides a speed-up of the partial wave fit by more than two orders of magnitude compared to legacy FORTRAN code.

  14. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  15. Fast Partial Evaluation of Pattern Matching in Strings

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Rohde, Henning Korsholm

    2006-01-01

    We show how to obtain all of Knuth, Morris, and Pratt's linear-time string matcher by specializing a quadratic-time string matcher with respect to a pattern string. Although it has been known for 15 years how to obtain this linear matcher by partial evaluation of a quadratic one, how to obtain...... it in linear time has remained an open problem. Obtaining a linear matcher by partial evaluation of a quadratic one is achieved by performing its backtracking at specialization time and memoizing its results. We show (1) how to rewrite the source matcher such that its static intermediate computations can...... be shared at specialization time and (2) how to extend the memoization capabilities of a partial evaluator to static functions. Such an extended partial evaluator, if its memoization is implemented efficiently, specializes the rewritten source matcher in linear time. Finally, we show that the method also...

  16. Fast Partial Evaluation of Pattern Matching in Strings

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Rohde, Henning Korsholm

    2003-01-01

    We show how to obtain all of Knuth, Morris, and Pratt's linear-time string matcher by specializing a quadratic-time string matcher with respect to a pattern string. Although it has been known for 15 years how to obtain this linear matcher by partial evaluation of a quadratic one, how to obtain...... it in linear time has remained an open problem. Obtaining a linear matcher by partial evaluation of a quadratic one is achieved by performing its backtracking at specialization time and memoizing its results. We show (1) how to rewrite the source matcher such that its static intermediate computations can...... be shared at specialization time and (2) how to extend the memoization capabilities of a partial evaluator to static functions. Such an extended partial evaluator, if its memoization is implemented efficiently, specializes the rewritten source matcher in linear time. Finally, we show that the method also...

  17. Chiral and continuum extrapolation of partially quenched lattice results

    Energy Technology Data Exchange (ETDEWEB)

    C.R. Allton; W. Armour; D.B. Leinweber; A.W. Thomas; R.D. Young

    2005-04-01

    The vector meson mass is extracted from a large sample of partially quenched, two-flavor lattice QCD simulations. For the first time, discretization, finite-volume and partial quenching artifacts are treated in a unified chiral effective field theory analysis of the lattice simulation results.

  18. Applied partial differential equations

    CERN Document Server

    Logan, J David

    2015-01-01

    This text presents the standard material usually covered in a one-semester, undergraduate course on boundary value problems and PDEs.  Emphasis is placed on motivation, concepts, methods, and interpretation, rather than on formal theory. The concise treatment of the subject is maintained in this third edition covering all the major ideas: the wave equation, the diffusion equation, the Laplace equation, and the advection equation on bounded and unbounded domains. Methods include eigenfunction expansions, integral transforms, and characteristics. In this third edition, text remains intimately tied to applications in heat transfer, wave motion, biological systems, and a variety other topics in pure and applied science. The text offers flexibility to instructors who, for example, may wish to insert topics from biology or numerical methods at any time in the course. The exposition is presented in a friendly, easy-to-read, style, with mathematical ideas motivated from physical problems. Many exercises and worked e...

  19. Physics of partially ionized plasmas

    CERN Document Server

    Krishan, Vinod

    2016-01-01

    Plasma is one of the four fundamental states of matter; the other three being solid, liquid and gas. Several components, such as molecular clouds, diffuse interstellar gas, the solar atmosphere, the Earth's ionosphere and laboratory plasmas, including fusion plasmas, constitute the partially ionized plasmas. This book discusses different aspects of partially ionized plasmas including multi-fluid description, equilibrium and types of waves. The discussion goes on to cover the reionization phase of the universe, along with a brief description of high discharge plasmas, tokomak plasmas and laser plasmas. Various elastic and inelastic collisions amongst the three particle species are also presented. In addition, the author demonstrates the novelty of partially ionized plasmas using many examples; for instance, in partially ionized plasma the magnetic induction is subjected to the ambipolar diffusion and the Hall effect, as well as the usual resistive dissipation. Also included is an observation of kinematic dynam...

  20. Partially massless fields during inflation

    Science.gov (United States)

    Baumann, Daniel; Goon, Garrett; Lee, Hayden; Pimentel, Guilherme L.

    2018-04-01

    The representation theory of de Sitter space allows for a category of partially massless particles which have no flat space analog, but could have existed during inflation. We study the couplings of these exotic particles to inflationary perturbations and determine the resulting signatures in cosmological correlators. When inflationary perturbations interact through the exchange of these fields, their correlation functions inherit scalings that cannot be mimicked by extra massive fields. We discuss in detail the squeezed limit of the tensor-scalar-scalar bispectrum, and show that certain partially massless fields can violate the tensor consistency relation of single-field inflation. We also consider the collapsed limit of the scalar trispectrum, and find that the exchange of partially massless fields enhances its magnitude, while giving no contribution to the scalar bispectrum. These characteristic signatures provide clean detection channels for partially massless fields during inflation.

  1. New applications of partial residual methodology

    International Nuclear Information System (INIS)

    Uslu, V.R.

    1999-12-01

    The formulation of a problem of interest in the framework of a statistical analysis starts with collecting the data, choosing a model, making certain assumptions as described in the basic paradigm by Box (1980). This stage is is called model building. Then the estimation stage is in order by pretending as if the formulation of the problem was true to obtain estimates, to make tests and inferences. In the final stage, called diagnostic checking, checking of whether there are some disagreements between the data and the model fitted is done by using diagnostic measures and diagnostic plots. It is well known that statistical methods perform best under the condition that all assumptions related to the methods are satisfied. However it is true that having the ideal case in practice is very difficult. Diagnostics are therefore becoming important so are diagnostic plots because they provide a immediate assessment. Partial residual plots that are the main interest of the present study are playing the major role among the diagnostic plots in multiple regression analysis. In statistical literature it is admitted that partial residual plots are more useful than ordinary residual plots in detecting outliers, nonconstant variance, and especially discovering curvatures. In this study we consider the partial residual methodology in statistical methods rather than multiple regression. We have shown that for the same purpose as in the multiple regression the use of partial residual plots is possible particularly in autoregressive time series models, transfer function models, linear mixed models and ridge regression. (author)

  2. Exergy of partially coherent thermal radiation

    International Nuclear Information System (INIS)

    Wijewardane, S.; Goswami, Yogi

    2012-01-01

    Exergy of electromagnetic radiation has been studied by a number of researchers for well over four decades in order to estimate the maximum conversion efficiencies of thermal radiation. As these researchers primarily dealt with solar and blackbody radiation, which have a low degree of coherence, they did not consider the partial coherence properties of thermal radiation. With the recent development of surface structures, which can emit radiation with high degree of coherence, the importance of considering the partial coherent properties in exergy calculation has become a necessity as the coherence properties directly influence the entropy of the wave field. Here in this paper we derive an expression for the exergy of quasi-monochromatic radiation using statistical thermodynamics and show that it is identical with the expressions derived using classical thermodynamics. We also present a method to calculate the entropy, thereby the exergy of partially coherent radiation using statistical thermodynamics and a method called matrix treatment of wave field. -- Highlights: ► Considered partial coherence of radiation for the first time to calculate exergy. ► The importance of this method is emphasized with energy conversion examples. ► Derived an expression for the exergy of radiation using statistical thermodynamics. ► Adopted a method to calculate intensity of statistically independent principle wave.

  3. Introduction to partial differential equations

    CERN Document Server

    Greenspan, Donald

    2000-01-01

    Designed for use in a one-semester course by seniors and beginning graduate students, this rigorous presentation explores practical methods of solving differential equations, plus the unifying theory underlying the mathematical superstructure. Topics include basic concepts, Fourier series, second-order partial differential equations, wave equation, potential equation, heat equation, approximate solution of partial differential equations, and more. Exercises appear at the ends of most chapters. 1961 edition.

  4. Stochastic partial differential equations

    CERN Document Server

    Lototsky, Sergey V

    2017-01-01

    Taking readers with a basic knowledge of probability and real analysis to the frontiers of a very active research discipline, this textbook provides all the necessary background from functional analysis and the theory of PDEs. It covers the main types of equations (elliptic, hyperbolic and parabolic) and discusses different types of random forcing. The objective is to give the reader the necessary tools to understand the proofs of existing theorems about SPDEs (from other sources) and perhaps even to formulate and prove a few new ones. Most of the material could be covered in about 40 hours of lectures, as long as not too much time is spent on the general discussion of stochastic analysis in infinite dimensions. As the subject of SPDEs is currently making the transition from the research level to that of a graduate or even undergraduate course, the book attempts to present enough exercise material to fill potential exams and homework assignments. Exercises appear throughout and are usually directly connected ...

  5. The partially filled viscous ring damper.

    Science.gov (United States)

    Alfriend, K. T.

    1973-01-01

    The problem of a spinning satellite with a partially filled viscous ring damper is investigated. It is shown that there are two distinct modes of motion, the nutation-synchronous mode and spin-synchronous mode. From an approximate solution of the equations of motion a time constant is obtained for each mode. From a consideration of the fluid dynamics several methods are developed for determining the damping constant.

  6. A partial snake for the AGS

    International Nuclear Information System (INIS)

    Ratner, L.G.

    1990-01-01

    Based on snake experiments at the Indian University Cyclotron Facility and computer simulations at Brookhaven National Laboratory, as well as the conclusions of a BNL mini-workshop, we feel that a partial Siberian snake is a practical device for the AGS. It is anticipated that such a device could reduce the polarized beam tune-up time from 2--3 weeks to 2--3 days

  7. Telescopic Partial Dentures-Concealed Technology

    OpenAIRE

    Bhagat, Tushar Vitthalrao; Walke, Ashwini Nareshchandra

    2015-01-01

    The ideal goal of good dentist is to restore the missing part of oral structure, phonetics, his look and the most important is restored the normal health of the patient, which is hampered due to less or insufficient intake of food. Removable partial denture (RPD) treatment option is considered as a notion, which precludes the inevitability of ?floating plastic? in edentulous mouth, that many times fail to fulfill the above essential of the patients. In modern dentistry, though the dental impl...

  8. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  9. Partially integrable nonlinear equations with one higher symmetry

    International Nuclear Information System (INIS)

    Mikhailov, A V; Novikov, V S; Wang, J P

    2005-01-01

    In this letter, we present a family of second order in time nonlinear partial differential equations, which have only one higher symmetry. These equations are not integrable, but have a solution depending on one arbitrary function. (letter to the editor)

  10. Partial avascular necrosis after talar neck fracture.

    Science.gov (United States)

    Babu, Nina; Schuberth, John M

    2010-09-01

    Recently, it has been shown that avascular necrosis of the talus can occur in only a portion of the talar body. There is little information regarding the geographic location of the avascular segment and the clinical significance of an incomplete avascular process. Seven patients with partial avascular necrosis after Hawkins type II or III fracture dislocations were evaluated with magnetic resonance scans. The precise anatomic location of the avascular segment was determined and assigned to a specific quadrant of the talar body. The operative exposure, incidence of collapse, and time to operative intervention was recorded. The avascular segment of the talar body was located predominantly in the anterior lateral and superior portion in six of the seven patients. Collapse occurred in three of the patients in the area of avascular process. There were no observable trends with regard to operative exposure, Hawkins classification, incidence of collapse, or time to operative intervention to the location of the avascular segment. Partial avascular necrosis can occur after fracture dislocation of the talus. The predominant location of the avascular segment was the anterior lateral and superior portion of the talar body. This observation corresponds to regional damage to the blood supply of the talus and may help clarify the pathogenesis of partial avascular process.

  11. Magnetic properties of partially oxidized Fe films

    Science.gov (United States)

    Garcia, Miguel Angel; Lopez-Dominguez, Victor; Hernando, Antonio

    Hybrid magnetic nanostructures exhibit appealing properties due to interface and proximity effects. A simple and interesting system of hybrid magnetic nanomaterials are partially oxidized ferromagnetic films. We have fabricated Fe films by thermal evaporation and performed a partial oxidation to magnetite (Fe3O4) by annealing in air at different times and temperatures. The magnetic properties of the films evolve from those of pure metallic iron to pure magnetite, showing intermediate states where the proximity effects control the magnetic behavior. At some stages, the magnetization curves obtained by SQUID and MOKE magnetometry exhibit important differences due to the dissimilar contribution of both phases to the magneto-optical response of the system This work has been supported by the Ministerio Español de Economia y Competitividad (MINECO) MAT2013-48009-C4-1. V.L.D and M.A.G. acknowledges financial support from BBVA foundation.

  12. Local cerebral metabolism during partial seizures

    International Nuclear Information System (INIS)

    Engel, J. Jr.; Kuhl, D.E.; Phelps, M.E.; Rausch, R.; Nuwer, M.

    1983-01-01

    Interictal and ictal fluorodeoxyglucose scans were obtained with positron CT from four patients with spontaneous recurrent partial seizures, one with epilepsia partialis continua, and one with a single partial seizure induced by electrical stimulation of the hippocampus. Ictal metabolic patterns were different for each patient studied. Focal and generalized increased and decreased metabolism were observed. Ictal hypermetabolism may exceed six times the interictal rate and could represent activation of excitatory or inhibitory synapses in the epileptogenic region and its projection fields. Hypometabolism seen on ictal scans most likely reflects postictal depression and may indicate projection fields of inhibited neurons. No quantitative relationship between alterations in metabolism and EEG or behavioral measurements of ictal events could be demonstrated

  13. Local cerebral metabolism during partial seizures

    Energy Technology Data Exchange (ETDEWEB)

    Engel, J. Jr.; Kuhl, D.E.; Phelps, M.E.; Rausch, R.; Nuwer, M.

    1983-04-01

    Interictal and ictal fluorodeoxyglucose scans were obtained with positron CT from four patients with spontaneous recurrent partial seizures, one with epilepsia partialis continua, and one with a single partial seizure induced by electrical stimulation of the hippocampus. Ictal metabolic patterns were different for each patient studied. Focal and generalized increased and decreased metabolism were observed. Ictal hypermetabolism may exceed six times the interictal rate and could represent activation of excitatory or inhibitory synapses in the epileptogenic region and its projection fields. Hypometabolism seen on ictal scans most likely reflects postictal depression and may indicate projection fields of inhibited neurons. No quantitative relationship between alterations in metabolism and EEG or behavioral measurements of ictal events could be demonstrated.

  14. Stochastic partial differential equations an introduction

    CERN Document Server

    Liu, Wei

    2015-01-01

    This book provides an introduction to the theory of stochastic partial differential equations (SPDEs) of evolutionary type. SPDEs are one of the main research directions in probability theory with several wide ranging applications. Many types of dynamics with stochastic influence in nature or man-made complex systems can be modelled by such equations. The theory of SPDEs is based both on the theory of deterministic partial differential equations, as well as on modern stochastic analysis. Whilst this volume mainly follows the ‘variational approach’, it also contains a short account on the ‘semigroup (or mild solution) approach’. In particular, the volume contains a complete presentation of the main existence and uniqueness results in the case of locally monotone coefficients. Various types of generalized coercivity conditions are shown to guarantee non-explosion, but also a systematic approach to treat SPDEs with explosion in finite time is developed. It is, so far, the only book where the latter and t...

  15. Partial Transposition on Bipartite System

    International Nuclear Information System (INIS)

    Xi-Jun, Ren; Yong-Jian, Han; Yu-Chun, Wu; Guang-Can, Guo

    2008-01-01

    Many properties of partial transposition are unclear as yet. Here we carefully consider the number of the negative eigenvalues of ρ T (ρ's partial transposition) when ρ is a two-partite state. There is strong evidence to show that the number of negative eigenvalues of ρ T is N(N − 1)/2 at most when ρ is a state in Hilbert space C N C N . For the special case, the 2 × 2 system, we use this result to give a partial proof of the conjecture |ρ T | T ≥ 0. We find that this conjecture is strongly connected with the entanglement of the state corresponding to the negative eigenvalue of ρ T or the negative entropy of ρ

  16. Partial volume effect in MRI

    International Nuclear Information System (INIS)

    Maeda, Munehiro; Yoshiya, Kazuhiko; Suzuki, Eiji

    1989-01-01

    According to the direction and the thickness of the imaging slice in tomography, the border between the tissues becomes unclear (partial volume effect). In the present MRI experiment, we examined border area between fat and water components using phantom in order to investigate the partial volume effect in MRI. In spin echo sequences, the intensity of the border area showed a linear relationship with composition of fat and water. Whereas, in inversion recovery and field echo sequences, we found the parameters to produce an extremely low intensity area at the border region between fat and water. This low intensity area was explained by cancellation of NMR signals from fat and water due to the difference in the direction of magnetic vectors. Clinically, partial volume effect can cause of mis-evaluation of walls, small nodules, tumor capsules and the tumor invasion in the use of inversion recovery and field echo sequences. (author)

  17. Partially composite Goldstone Higgs boson

    DEFF Research Database (Denmark)

    Alanne, Tommi; Franzosi, Diogo Buarque; Frandsen, Mads T.

    2017-01-01

    We consider a model of dynamical electroweak symmetry breaking with a partially composite Goldstone Higgs boson. The model is based on a strongly interacting fermionic sector coupled to a fundamental scalar sector via Yukawa interactions. The SU(4)×SU(4) global symmetry of these two sectors...... is broken to a single SU(4) via Yukawa interactions. Electroweak symmetry breaking is dynamically induced by condensation due to the strong interactions in the new fermionic sector which further breaks the global symmetry SU(4)→Sp(4). The Higgs boson arises as a partially composite state which is an exact...... Goldstone boson in the limit where SM interactions are turned off. Terms breaking the SU(4) global symmetry explicitly generate a mass for the Goldstone Higgs boson. The model realizes in different limits both (partially) composite Higgs and (bosonic) technicolor models, thereby providing a convenient...

  18. Basic linear partial differential equations

    CERN Document Server

    Treves, Francois

    1975-01-01

    Focusing on the archetypes of linear partial differential equations, this text for upper-level undergraduates and graduate students features most of the basic classical results. The methods, however, are decidedly nontraditional: in practically every instance, they tend toward a high level of abstraction. This approach recalls classical material to contemporary analysts in a language they can understand, as well as exploiting the field's wealth of examples as an introduction to modern theories.The four-part treatment covers the basic examples of linear partial differential equations and their

  19. Elements of partial differential equations

    CERN Document Server

    Sneddon, Ian Naismith

    1957-01-01

    Geared toward students of applied rather than pure mathematics, this volume introduces elements of partial differential equations. Its focus is primarily upon finding solutions to particular equations rather than general theory.Topics include ordinary differential equations in more than two variables, partial differential equations of the first and second orders, Laplace's equation, the wave equation, and the diffusion equation. A helpful Appendix offers information on systems of surfaces, and solutions to the odd-numbered problems appear at the end of the book. Readers pursuing independent st

  20. Hubungan Hiperglikemia dengan Prothrombin Time pada Mencit (Mus musculus yang Diinduksi Aloksan

    Directory of Open Access Journals (Sweden)

    Muhammad Ibnu Malik

    2015-01-01

    . Endothelial disfungtion can be detected by activated partial thromboplastin time (APTT and prothrombin time (PT. The objective of this studi was to determine the correlation between hyperglycemia and prothrombin time in mice (Mus musculus induced with aloxan. The design of this research was a post test only control group design conducted in October 2013 until February 2014 in Central Laboratory RS Dr. M. Djamil Padang. The subject were white mice (Mus musculus who have met the inclusion and exclusion criteria. The subject were divided as hyperglycemia group (induced with aloxan and control group. After seven days of adaptation, the aloxan was injected and measurenment of blood glucose and body weight had been done, one time in every four days. Then in day 30th the termination of mice had been done to meassure the prothrombin time. The result showed the prothrombin time between group was shortened with the average prothrombin time of the control group was 7,96 second and the hiperglicemia group was 8,12 second. The result showing no correlation between hyperglycemia and prothrombin time with the degree of signification is (p 0,7 (p > 0,05.Keywords: hyperglycemia, diabetes mellitus, prothrombin time,

  1. Variable Selection via Partial Correlation.

    Science.gov (United States)

    Li, Runze; Liu, Jingyuan; Lou, Lejia

    2017-07-01

    Partial correlation based variable selection method was proposed for normal linear regression models by Bühlmann, Kalisch and Maathuis (2010) as a comparable alternative method to regularization methods for variable selection. This paper addresses two important issues related to partial correlation based variable selection method: (a) whether this method is sensitive to normality assumption, and (b) whether this method is valid when the dimension of predictor increases in an exponential rate of the sample size. To address issue (a), we systematically study this method for elliptical linear regression models. Our finding indicates that the original proposal may lead to inferior performance when the marginal kurtosis of predictor is not close to that of normal distribution. Our simulation results further confirm this finding. To ensure the superior performance of partial correlation based variable selection procedure, we propose a thresholded partial correlation (TPC) approach to select significant variables in linear regression models. We establish the selection consistency of the TPC in the presence of ultrahigh dimensional predictors. Since the TPC procedure includes the original proposal as a special case, our theoretical results address the issue (b) directly. As a by-product, the sure screening property of the first step of TPC was obtained. The numerical examples also illustrate that the TPC is competitively comparable to the commonly-used regularization methods for variable selection.

  2. Adaptive Partially Hidden Markov Models

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Rasmussen, Tage

    1996-01-01

    Partially Hidden Markov Models (PHMM) have recently been introduced. The transition and emission probabilities are conditioned on the past. In this report, the PHMM is extended with a multiple token version. The different versions of the PHMM are applied to bi-level image coding....

  3. Partially molten magma ocean model

    International Nuclear Information System (INIS)

    Shirley, D.N.

    1983-01-01

    The properties of the lunar crust and upper mantle can be explained if the outer 300-400 km of the moon was initially only partially molten rather than fully molten. The top of the partially molten region contained about 20% melt and decreased to 0% at 300-400 km depth. Nuclei of anorthositic crust formed over localized bodies of magma segregated from the partial melt, then grew peripherally until they coverd the moon. Throughout most of its growth period the anorthosite crust floated on a layer of magma a few km thick. The thickness of this layer is regulated by the opposing forces of loss of material by fractional crystallization and addition of magma from the partial melt below. Concentrations of Sr, Eu, and Sm in pristine ferroan anorthosites are found to be consistent with this model, as are trends for the ferroan anorthosites and Mg-rich suites on a diagram of An in plagioclase vs. mg in mafics. Clustering of Eu, Sr, and mg values found among pristine ferroan anorthosites are predicted by this model

  4. [Posterior ceramic bonded partial restorations].

    Science.gov (United States)

    Mainjot, Amélie; Vanheusden, Alain

    2006-01-01

    Posterior ceramic bonded partial restorations are conservative and esthetic approaches for compromised teeth. Overlays constitute a less invasive alternative for tooth tissues than crown preparations. With inlays and onlays they are also indicated in case of full arch or quadrant rehabilitations including several teeth. This article screens indications and realization of this type of restorations.

  5. Implementing circularity using partial evaluation

    DEFF Research Database (Denmark)

    Lawall, Julia Laetitia

    2001-01-01

    of an imperative C-like language, by extending the language with a new construct, persistent variables. We show that an extension of partial evaluation can eliminate persistent variables, producing a staged C program. This approach has been implemented in the Tempo specializer for C programs, and has proven useful...

  6. Accuracy of MR imaging in partial tears of rotator cuff

    International Nuclear Information System (INIS)

    Eto, Masao; Ito, Nobuyuki; Tomonaga, Tadashi; Harada, Shin'ichi; Rabbi, M.E.; Iwasaki, Katsuro

    1997-01-01

    MRI is very useful for the diagnosis of the rotator cuff tear However. in case of partial tears it is sometimes controvertible. In this study, we studied the accuracy of MRI in the diagnosis of partial tears. 67 patients who underwent MRI investigation before operation were chosen for this study. There were 61 males and 6 females, ranging from 30 to 80 years (mean: 54.8 years at the time of operation). MRI was performed with 1.5T superconductive system with shoulder surface coil. MPGR T2-weighted images were performed in the coronal oblique and sagittal oblique planes. Complete tears were diagnosed when full thickness high intensity was observed in the rotator cuff, whereas with partial high intensity of the rotator cuff, was considered as partial tears. MRI demonstrated 77.8% sensitivity, 91.4% specificity and 89.6% accuracy in the diagnosis of partial tear. In 8 cases MRI had misinterpretation. In MPGR T2-weighted images, not only the partial tears but the degenerative changes also show high intensity of the rotator cuff. Therefore, it is difficult to differentiate and maybe this is the reason of misinterpretations of partial tears by MRI. MRI provided with useful pre-operative informations of partial tears of the rotator cuff. However, in few cases it is hard to differentiate for the degenerative changes of the rotator cuff. (author)

  7. Memoization in Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Balat, Vincent; Danvy, Olivier

    2002-01-01

    We use a code generator—type-directed partial evaluation— to verify conversions between isomorphic types, or more precisely to verify that a composite function is the identity function at some complicated type. A typed functional language such as ML provides a natural support to express the funct......We use a code generator—type-directed partial evaluation— to verify conversions between isomorphic types, or more precisely to verify that a composite function is the identity function at some complicated type. A typed functional language such as ML provides a natural support to express...... originate in the handling of sums, which uses delimited continuations. We successfully eliminate these redundancies by extending type-directed partial evaluation with memoization capabilities. The result only works for pure functional programs, but it provides an unexpected use of code generation...... and it yields orders-of-magnitude improvements both in time and in space for type isomorphisms. Basic Research in Computer Science (www. brics. dk), funded by the Danish National Research Foundation....

  8. Optimal partial-arcs in VMAT treatment planning

    International Nuclear Information System (INIS)

    Wala, Jeremiah; Salari, Ehsan; Chen Wei; Craft, David

    2012-01-01

    We present a method for improving the delivery efficiency of VMAT by extending the recently published VMAT treatment planning algorithm vmerge to automatically generate optimal partial-arc plans. A high-quality initial plan is created by solving a convex multicriteria optimization problem using 180 equi-spaced beams. This initial plan is used to form a set of dose constraints, and a set of partial-arc plans is created by searching the space of all possible partial-arc plans that satisfy these constraints. For each partial-arc, an iterative fluence map merging and sequencing algorithm (vmerge) is used to improve the delivery efficiency. Merging continues as long as the dose quality is maintained above a user-defined threshold. The final plan is selected as the partial-arc with the lowest treatment time. The complete algorithm is called pmerge. Partial-arc plans are created using pmerge for a lung, liver and prostate case, with final treatment times of 127, 245 and 147 s. Treatment times using full arcs with vmerge are 211, 357 and 178 s. The mean doses to the critical structures for the vmerge and pmerge plans are kept within 5% of those in the initial plan, and the target volume covered by the prescription isodose is maintained above 98% for the pmerge and vmerge plans. Additionally, we find that the angular distribution of fluence in the initial plans is predictive of the start and end angles of the optimal partial-arc. We conclude that VMAT delivery efficiency can be improved by employing partial-arcs without compromising dose quality, and that partial-arcs are most applicable to cases with non-centralized targets. (paper)

  9. Prospective study of robotic partial nephrectomy for renal cancer in Japan: Comparison with a historical control undergoing laparoscopic partial nephrectomy.

    Science.gov (United States)

    Tanaka, Kazushi; Teishima, Jun; Takenaka, Atsushi; Shiroki, Ryoichi; Kobayashi, Yasuyuki; Hattori, Kazunori; Kanayama, Hiro-Omi; Horie, Shigeo; Yoshino, Yasushi; Fujisawa, Masato

    2018-05-01

    To evaluate the outcomes of robotic partial nephrectomy compared with those of laparoscopic partial nephrectomy for T1 renal tumors in Japanese centers. Patients with a T1 renal tumor who underwent robotic partial nephrectomy were eligible for inclusion in the present study. The primary end-point consisted of three components: a negative surgical margin, no conversion to open or laparoscopic surgery and a warm ischemia time ≤25 min. We compared data from these patients with the data from a retrospective study of laparoscopic partial nephrectomy carried out in Japan. A total of 108 patients were registered in the present study; 105 underwent robotic partial nephrectomy. The proportion of patients who met the primary end-point was 91.3% (95% confidence interval 84.1-95.9%), which was significantly higher than 23.3% in the historical data. Major complications were seen in 19 patients (18.1%). The mean change in the estimated glomerular filtration rate in the operated kidney, 180 days postoperatively, was -10.8 mL/min/1.73 m 2 (95% confidence interval -12.3-9.4%). Robotic partial nephrectomy for patients with a T1 renal tumor is a safe, feasible and more effective operative method compared with laparoscopic partial nephrectomy. It can be anticipated that robotic partial nephrectomy will become more widely used in Japan in the future. © 2018 The Japanese Urological Association.

  10. Robust Throughput Boosting for Low Latency Dynamic Partial Reconfiguration

    DEFF Research Database (Denmark)

    Nannarelli, Alberto; Re, M.; Cardarilli, Gian Carlo

    2017-01-01

    Reducing the configuration time of portions of an FPGA at run time is crucial in contemporary FPGA-based accelerators. In this work, we propose a method to increase the throughput for FPGA dynamic partial reconfiguration by using standard IP blocks. The throughput is increased by over-clocking th......Reducing the configuration time of portions of an FPGA at run time is crucial in contemporary FPGA-based accelerators. In this work, we propose a method to increase the throughput for FPGA dynamic partial reconfiguration by using standard IP blocks. The throughput is increased by over...

  11. Partial networking. Deactivation of inactive ECUs; Teilnetzbetrieb. Abschaltung inaktiver Steuergeraete

    Energy Technology Data Exchange (ETDEWEB)

    Esch, Stephan [Audi AG, Ingolstadt (Germany); Meyer, Juergen [Audi AG, Ingolstadt (Germany). Projekt Teilnetzbetrieb und WakeUp-Sleep-Konzepte; Linn, Guenter [Audi AG, Ingolstadt (Germany). Bereich Physical Layer Flexray und Hardware-Teilnetzbetrieb

    2012-02-15

    CAN partial networking technology makes it possible to reduce power consumption and ensures energy efficiency during both operating and idle time. Audi is developing and standardizing this technology in collaboration with other OEMs and semiconductor manufacturers. Partial networking technology will become an inherent item in the Volkswagen Group Networking Technology Kit, with series production planned to begin in 2014. The article deals with the development, application and verification of partial network technology at Audi. The standardization process within the OEM overarching bodies Switch, Autosar and ISO is also outlined. (orig.)

  12. The strategic value of partial vertical integration

    OpenAIRE

    Fiocco, Raffaele

    2014-01-01

    We investigate the strategic incentives for partial vertical integration, namely, partial ownership agreements between manufacturers and retailers, when retailers privately know their costs and engage in differentiated good price competition. The partial misalignment between the profit objectives within a partially integrated manufacturer-retailer hierarchy entails a higher retail price than under full integration. This `information vertical effect' translates into an opposite ...

  13. 32 CFR 751.13 - Partial payments.

    Science.gov (United States)

    2010-07-01

    ... voucher and all other information related to the partial payment shall be placed in the claim file. Action... 32 National Defense 5 2010-07-01 2010-07-01 false Partial payments. 751.13 Section 751.13 National... Claims Against the United States § 751.13 Partial payments. (a) Partial payments when hardship exists...

  14. Partial differential equation models in macroeconomics.

    Science.gov (United States)

    Achdou, Yves; Buera, Francisco J; Lasry, Jean-Michel; Lions, Pierre-Louis; Moll, Benjamin

    2014-11-13

    The purpose of this article is to get mathematicians interested in studying a number of partial differential equations (PDEs) that naturally arise in macroeconomics. These PDEs come from models designed to study some of the most important questions in economics. At the same time, they are highly interesting for mathematicians because their structure is often quite difficult. We present a number of examples of such PDEs, discuss what is known about their properties, and list some open questions for future research. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  15. Fibrinogen Test

    Science.gov (United States)

    ... thrombotic episode ) As a follow-up to an abnormal bleeding disorder test ( prothrombin time, PT or partial thromboplastin time, ... to help diagnose disseminated intravascular coagulation (DIC) or abnormal ... status of a progressive disease (such as liver disease ) over time or, rarely, ...

  16. Numerical Analysis for Stochastic Partial Differential Delay Equations with Jumps

    OpenAIRE

    Li, Yan; Hu, Junhao

    2013-01-01

    We investigate the convergence rate of Euler-Maruyama method for a class of stochastic partial differential delay equations driven by both Brownian motion and Poisson point processes. We discretize in space by a Galerkin method and in time by using a stochastic exponential integrator. We generalize some results of Bao et al. (2011) and Jacob et al. (2009) in finite dimensions to a class of stochastic partial differential delay equations with jumps in infinite dimensions.

  17. Removable partial dentures: clinical concepts.

    Science.gov (United States)

    Bohnenkamp, David M

    2014-01-01

    This article provides a review of the traditional clinical concepts for the design and fabrication of removable partial dentures (RPDs). Although classic theories and rules for RPD designs have been presented and should be followed, excellent clinical care for partially edentulous patients may also be achieved with computer-aided design/computer-aided manufacturing technology and unique blended designs. These nontraditional RPD designs and fabrication methods provide for improved fit, function, and esthetics by using computer-aided design software, composite resin for contours and morphology of abutment teeth, metal support structures for long edentulous spans and collapsed occlusal vertical dimensions, and flexible, nylon thermoplastic material for metal-supported clasp assemblies. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. The marketing of partial hospitalization.

    Science.gov (United States)

    Millsap, P; Brown, E; Kiser, L; Pruitt, D

    1987-09-01

    Health-care professionals are currently operating in the context of a rapidly changing health-care delivery system, including the move away from inpatient services to outpatient services in order to control costs. Those who practice in partial-hospital settings are in a position to offer effective, cost-efficient services; however, there continue to be obstacles which hinder appropriate utilization of the modality. The development and use of a well-designed marketing plan is one strategy for removing these obstacles. This paper presents a brief overview of the marketing process, ideas for developing a marketing plan, and several examples of specific marketing strategies as well as ways to monitor their effectiveness. Partial-hospital providers must take an active role in answering the calls for alternative sources of psychiatric care. A comprehensive, education-oriented marketing approach will increase the public's awareness of such alternatives and enable programs to survive in a competitive environment.

  19. Introduction to partial differential equations

    CERN Document Server

    Borthwick, David

    2016-01-01

    This modern take on partial differential equations does not require knowledge beyond vector calculus and linear algebra. The author focuses on the most important classical partial differential equations, including conservation equations and their characteristics, the wave equation, the heat equation, function spaces, and Fourier series, drawing on tools from analysis only as they arise.Within each section the author creates a narrative that answers the five questions: (1) What is the scientific problem we are trying to understand? (2) How do we model that with PDE? (3) What techniques can we use to analyze the PDE? (4) How do those techniques apply to this equation? (5) What information or insight did we obtain by developing and analyzing the PDE? The text stresses the interplay between modeling and mathematical analysis, providing a thorough source of problems and an inspiration for the development of methods.

  20. Dynamics of partial differential equations

    CERN Document Server

    Wayne, C Eugene

    2015-01-01

    This book contains two review articles on the dynamics of partial differential equations that deal with closely related topics but can be read independently. Wayne reviews recent results on the global dynamics of the two-dimensional Navier-Stokes equations. This system exhibits stable vortex solutions: the topic of Wayne's contribution is how solutions that start from arbitrary initial conditions evolve towards stable vortices. Weinstein considers the dynamics of localized states in nonlinear Schrodinger and Gross-Pitaevskii equations that describe many optical and quantum systems. In this contribution, Weinstein reviews recent bifurcations results of solitary waves, their linear and nonlinear stability properties, and results about radiation damping where waves lose energy through radiation.   The articles, written independently, are combined into one volume to showcase the tools of dynamical systems theory at work in explaining qualitative phenomena associated with two classes of partial differential equ...

  1. Partial Cooperative Equilibria: Existence and Characterization

    Directory of Open Access Journals (Sweden)

    Amandine Ghintran

    2010-09-01

    Full Text Available We study the solution concepts of partial cooperative Cournot-Nash equilibria and partial cooperative Stackelberg equilibria. The partial cooperative Cournot-Nash equilibrium is axiomatically characterized by using notions of rationality, consistency and converse consistency with regard to reduced games. We also establish sufficient conditions for which partial cooperative Cournot-Nash equilibria and partial cooperative Stackelberg equilibria exist in supermodular games. Finally, we provide an application to strategic network formation where such solution concepts may be useful.

  2. Partial dependency parsing for Irish

    OpenAIRE

    Uí Dhonnchadha, Elaine; van Genabith, Josef

    2010-01-01

    In this paper we present a partial dependency parser for Irish, in which Constraint Grammar (CG) rules are used to annotate dependency relations and grammatical functions in unrestricted Irish text. Chunking is performed using a regular-expression grammar which operates on the dependency tagged sentences. As this is the first implementation of a parser for unrestricted Irish text (to our knowledge), there were no guidelines or precedents available. Therefore deciding what constitutes a syntac...

  3. Matching games with partial information

    Science.gov (United States)

    Laureti, Paolo; Zhang, Yi-Cheng

    2003-06-01

    We analyze different ways of pairing agents in a bipartite matching problem, with regard to its scaling properties and to the distribution of individual “satisfactions”. Then we explore the role of partial information and bounded rationality in a generalized Marriage Problem, comparing the benefits obtained by self-searching and by a matchmaker. Finally we propose a modified matching game intended to mimic the way consumers’ information makes firms to enhance the quality of their products in a competitive market.

  4. Succinct partial sums and fenwick trees

    DEFF Research Database (Denmark)

    Bille, Philip; Christiansen, Anders Roy; Prezza, Nicola

    2017-01-01

    We consider the well-studied partial sums problem in succint space where one is to maintain an array of n k-bit integers subject to updates such that partial sums queries can be efficiently answered. We present two succint versions of the Fenwick Tree – which is known for its simplicity...... and practicality. Our results hold in the encoding model where one is allowed to reuse the space from the input data. Our main result is the first that only requires nk + o(n) bits of space while still supporting sum/update in O(logbn)/O(blogbn) time where 2 ≤ b ≤ log O(1)n. The second result shows how optimal...... time for sum/update can be achieved while only slightly increasing the space usage to nk + o(nk) bits. Beyond Fenwick Trees, the results are primarily based on bit-packing and sampling – making them very practical – and they also allow for simple optimal parallelization....

  5. Four-factor prothrombin complex concentrate improves thrombin generation and prothrombin time in patients with bleeding complications related to rivaroxaban: a single-center pilot trial.

    Science.gov (United States)

    Schenk, Bettina; Goerke, Stephanie; Beer, Ronny; Helbok, Raimund; Fries, Dietmar; Bachler, Mirjam

    2018-01-01

    Direct oral anticoagulants (DOACs) pose a great challenge for physicians in life-threatening bleeding events. The aim of this study was to test the efficacy of reversing the DOAC rivaroxaban using four-factor PCC (prothrombin complex concentrate), a non-specific reversing agent. Patients with life-threatening bleeding events during rivaroxaban treatment were included and administered 25 U kg -1 of PCC. Blood samples were collected immediately prior to as well as after PCC treatment at predefined time intervals. The primary endpoint was defined as the difference in thrombin generation (TG) parameters ETP (endogenous thrombin potential) and C max (peak thrombin generation) prior to and ten minutes subsequent to PCC treatment. Thirteen patients, of whom the majority suffered from intra-cranial haemorrhage (ICH) or subdural haemorrhage (SDH), were included and administered PCC. The results show that the ETP (TG) significantly ( p  = 0.001) improved by 68% and C max (TG) by 54% (p = 0.001) during PCC treatment. In addition, the Quick value (prothrombin time: Quick PT ) significantly improved by 28% and the activated partial thromboplastin time (aPTT) was decreased by 7% ten minutes after PCC administration. C max was reduced at baseline, but not ETP, aPTT or Quick PT . Lag time until initiation (TG, t lag ), thromboelastometry clotting time (CT EXTEM ) and time to peak (TG, t max ) correlated best with measured rivaroxaban levels and were out of normal ranges at baseline, but did not improve after PCC administration. In 77% of the patients bleeding (ICH/SDH-progression) ceased following PCC administration. During the study three participants passed away due to other complications not related to PCC treatment. The possibility of thrombosis formation was also evaluated seven days after administering PCC and no thromboses were found. This study shows that use of PCC improved ETP, C max, Quick PT and aPTT. However, of these parameters, only C max was reduced at the

  6. Synchronizing Strategies under Partial Observability

    DEFF Research Database (Denmark)

    Larsen, Kim Guldstrand; Laursen, Simon; Srba, Jiri

    2014-01-01

    Embedded devices usually share only partial information about their current configurations as the communication bandwidth can be restricted. Despite this, we may wish to bring a failed device into a given predetermined configuration. This problem, also known as resetting or synchronizing words, has...... been intensively studied for systems that do not provide any information about their configurations. In order to capture more general scenarios, we extend the existing theory of synchronizing words to synchronizing strategies, and study the synchronization, short-synchronization and subset...

  7. Partial differential equations an introduction

    CERN Document Server

    Colton, David

    2004-01-01

    Intended for a college senior or first-year graduate-level course in partial differential equations, this text offers students in mathematics, engineering, and the applied sciences a solid foundation for advanced studies in mathematics. Classical topics presented in a modern context include coverage of integral equations and basic scattering theory. This complete and accessible treatment includes a variety of examples of inverse problems arising from improperly posed applications. Exercises at the ends of chapters, many with answers, offer a clear progression in developing an understanding of

  8. Laparoscopic Partial Hepatectomy: Animal Experiments

    Directory of Open Access Journals (Sweden)

    Haruhiro Inoue

    1995-01-01

    Full Text Available As a first step in firmly establishing laparoscopic hepatectomy, we introduce a porcine model of laparoscopic partial hepatectomy. This procedure has been successfully performed under the normal-pressure or low-pressure pneumoperitoneum condition supported by the full-thickness abdominal wall lifting technique. An ultrasonic dissector combined with electrocautery, newly developed by Olympus Optical Corporation (Japan was effectively utilized in facilitating safe and smooth incisions into the liver parenchyma. Although indications for this procedure seem to be limited only to peripheral lesions and not to central lesions, clinical application of this method may be useful for some patients in the near future.

  9. Partial differential equations & boundary value problems with Maple

    CERN Document Server

    Articolo, George A

    2009-01-01

    Partial Differential Equations and Boundary Value Problems with Maple presents all of the material normally covered in a standard course on partial differential equations, while focusing on the natural union between this material and the powerful computational software, Maple. The Maple commands are so intuitive and easy to learn, students can learn what they need to know about the software in a matter of hours- an investment that provides substantial returns. Maple''s animation capabilities allow students and practitioners to see real-time displays of the solutions of partial differential equations.  Maple files can be found on the books website. Ancillary list: Maple files- http://www.elsevierdirect.com/companion.jsp?ISBN=9780123747327  Provides a quick overview of the software w/simple commands needed to get startedIncludes review material on linear algebra and Ordinary Differential equations, and their contribution in solving partial differential equationsIncorporates an early introduction to Sturm-L...

  10. Phylogenetic search through partial tree mixing

    Science.gov (United States)

    2012-01-01

    Background Recent advances in sequencing technology have created large data sets upon which phylogenetic inference can be performed. Current research is limited by the prohibitive time necessary to perform tree search on a reasonable number of individuals. This research develops new phylogenetic algorithms that can operate on tens of thousands of species in a reasonable amount of time through several innovative search techniques. Results When compared to popular phylogenetic search algorithms, better trees are found much more quickly for large data sets. These algorithms are incorporated in the PSODA application available at http://dna.cs.byu.edu/psoda Conclusions The use of Partial Tree Mixing in a partition based tree space allows the algorithm to quickly converge on near optimal tree regions. These regions can then be searched in a methodical way to determine the overall optimal phylogenetic solution. PMID:23320449

  11. The effect of tobacco snuff on blood coagulation parameters in adult ...

    African Journals Online (AJOL)

    This study evaluates the effect of tobacco snuff on platelet count, prothrombin time (PT), and partial thromboplastin time (aPTT) in adult Wistar rats weighing between 150-300g and divided into four group (A - D; n=12 each). Group A served as control, while B, C and D served as test groups. The test groups were further ...

  12. Clinical effect of Fuzheng quyu therapy in patients undergoing ...

    African Journals Online (AJOL)

    Clinical effect of Fuzheng quyu therapy in patients undergoing radiotherapy after cervical carcinoma surgery. ... The clinical effects and the incidence of adverse events were compared between the groups. Results: The plasma prothrombin time and activated partial thromboplastin time improved after treatment in the study ...

  13. Polynomial Time Decidability of Weighted Synchronization under Partial Observability

    DEFF Research Database (Denmark)

    Kretínsky, Jan; Larsen, Kim Guldstrand; Laursen, Simon

    2015-01-01

    We consider weighted automata with both positive and negative integer weights on edges and study the problem of synchronization using adaptive strategies that may only observe whether the current weight-level is negative or nonnegative. We show that the synchronization problem is decidable...

  14. Pricing of Claims in Discrete Time with Partial Information

    Energy Technology Data Exchange (ETDEWEB)

    Rognlien Dahl, Kristina, E-mail: kristrd@math.uio.no [University of Oslo, Department of Mathematics (Norway)

    2013-10-15

    We consider the pricing problem of a seller with delayed price information. By using Lagrange duality, a dual problem is derived, and it is proved that there is no duality gap. This gives a characterization of the seller's price of a contingent claim. Finally, we analyze the dual problem, and compare the prices offered by two sellers with delayed and full information respectively.

  15. Pricing of Claims in Discrete Time with Partial Information

    International Nuclear Information System (INIS)

    Rognlien Dahl, Kristina

    2013-01-01

    We consider the pricing problem of a seller with delayed price information. By using Lagrange duality, a dual problem is derived, and it is proved that there is no duality gap. This gives a characterization of the seller’s price of a contingent claim. Finally, we analyze the dual problem, and compare the prices offered by two sellers with delayed and full information respectively

  16. Acquisition with partial and continuous reinforcement in pigeon autoshaping.

    Science.gov (United States)

    Gottlieb, Daniel A

    2004-08-01

    Contemporary time accumulation models make the unique prediction that acquisition of a conditioned response will be equally rapid with partial and continuous reinforcement, if the time between conditioned stimuli is held constant. To investigate this, acquisition of conditioned responding was examined in pigeon autoshaping under conditions of 100% and 25% reinforcement, holding intertrial interval constant. Contrary to what was predicted, evidence for slowed acquisition in partially reinforced animals was observed with several response measures. However, asymptotic performance was superior with 25% reinforcement. A switching of reinforcement contingencies after initial acquisition did not immediately affect responding. After further sessions, partial reinforcement augmented responding, whereas continuous reinforcement did not, irrespective of an animal's reinforcement history. Subsequent training with a novel stimulus maintained the response patterns. These acquisition results generally support associative, rather than time accumulation, accounts of conditioning.

  17. Abstract methods in partial differential equations

    CERN Document Server

    Carroll, Robert W

    2012-01-01

    Detailed, self-contained treatment examines modern abstract methods in partial differential equations, especially abstract evolution equations. Suitable for graduate students with some previous exposure to classical partial differential equations. 1969 edition.

  18. Male patients with partial androgen insensitivity syndrome

    DEFF Research Database (Denmark)

    Hellmann, Philip; Christiansen, Peter; Johannsen, Trine Holm

    2012-01-01

    To describe the natural history of phenotype, growth and gonadal function in patients with partial androgen insensitivity syndrome.......To describe the natural history of phenotype, growth and gonadal function in patients with partial androgen insensitivity syndrome....

  19. Time Discretization Techniques

    KAUST Repository

    Gottlieb, S.; Ketcheson, David I.

    2016-01-01

    The time discretization of hyperbolic partial differential equations is typically the evolution of a system of ordinary differential equations obtained by spatial discretization of the original problem. Methods for this time evolution include

  20. Decaying states as physically nonisolable partial systems

    International Nuclear Information System (INIS)

    Szasz, G.I.

    1976-01-01

    Presently the investigations of decaying quantum mechanical systems lack a well-founded concept, which is reflected by several formal difficulties of the corresponding mathematical treatment. In order to clarify in some respect the situation, it is investigated, within the framework of nonrelativistic quantum mechanics, the resonant scattering of an initially well localized partial wave packet. If the potential decreases sufficiently fast for r→infinite, the wave packet can be expressed at sufficiently long time after the scattering has taken place, as the sum of a term describing the direct scattering and a function of the resonant solution with complex 'momentum'. From such a heuristic relation one can deduce not only the probability for the creation of unstable particles but also obtain some hints to a connection between decaying states and physically nonisolable partial systems. On the other hand, this connection can perhaps display the inadequacy of attempts which suggest to solve the problem of decaying states within the usual Hilbert space methods. (author)

  1. [Removable partial dentures. Oral functions and types

    NARCIS (Netherlands)

    Creugers, N.H.J.; Baat, C. de

    2009-01-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic

  2. [Conventional retaining of removable partial dentures

    NARCIS (Netherlands)

    Keltjens, H.M.A.M.; Witter, D.J.; Creugers, N.H.J.

    2009-01-01

    Mechanical and biological criteria have to be met in retaining the metal frame of a removable partial denture. Additionally, a removable partial denture is part of the occlusal interface by the clasps and the denture teeth. With respect to mechanical aspects, all rigid parts of the removable partial

  3. Mathematical constraint on functions with continuous second partial derivatives

    International Nuclear Information System (INIS)

    Franson, J D

    2012-01-01

    A new integral identity for functions with continuous second partial derivatives is derived. It is shown that the value of any function f(r, t) at position r and time t is completely determined by its previous values at all other locations r′ and retarded times t′ ⩽ t, provided that the function vanishes at infinity and has continuous second partial derivatives. Functions of this kind occur in many areas of physics and it seems somewhat surprising that they are constrained in this way. (paper)

  4. Oculomotor impairment during chronic partial sleep deprivation.

    Science.gov (United States)

    Russo, M; Thomas, M; Thorne, D; Sing, H; Redmond, D; Rowland, L; Johnson, D; Hall, S; Krichmar, J; Balkin, T

    2003-04-01

    The effects of chronic partial sleep (sleep deprivation) and extended sleep (sleep augmentation) followed by recovery sleep on oculomotor function were evaluated in normal subjects to explore the usefulness of oculomotor assessment for alertness monitoring in fitness-for-duty testing. Sixty-six commercial drivers (24-62 years, 50m/16f) participated in a 15 day study composed of 3 training days with 8h time in bed per night, 7 experimental days with subjects randomly assigned to either 3, 5, 7, or 9h time in bed, and 3 recovery nights with 8h time in bed. Data from 57 subjects were used. Saccadic velocity (SV), initial pupil diameter (IPD), latency to pupil constriction (CL), and amplitude of pupil constriction (CA) were assessed and correlated with the sleep latency test (SLT), the Stanford sleepiness scale (SSS), and simulated driving performance. Regression analyses showed that SV slowed significantly in the 3 and 5h groups, IPD decreased significantly in the 9h group, and CL increased significantly in the 3h group. SLT and SSS significantly correlated with SV, IPD, CL, and driving accidents for the 3h group, and with CL for the 5h group. Analyses also showed a significant negative correlation between decreasing SV and increasing driving accidents in the 3h group and a significant negative correlation between IPD and driving accidents for the 7h group. The results demonstrate a sensitivity primarily of SV to sleepiness, and a correlation of SV and IPD to impaired simulated driving performance, providing evidence for the potential utility of oculomotor indicators in the detection of excessive sleepiness and deterioration of complex motor performance with chronic partial sleep restriction. This paper shows a relationship between sleep deprivation and oculomotor measures, and suggests a potential utility for oculometrics in assessing operational performance readiness under sleep restricted conditions.

  5. Precipitation in partially stabilized zirconia

    International Nuclear Information System (INIS)

    Bansal, G.K.

    1975-01-01

    Transmission electron microscopy was used to study the substructure of partially stabilized ZrO 2 (PSZ) samples, i.e., 2-phase systems containing both cubic and monoclinic modifications of zirconia, after various heat treatments. Monoclinic ZrO 2 exists as (1) isolated grains within the polycrystalline aggregate (a grain- boundary phase) and (2) small plate-like particles within cubic grains. These intragranular precipitates are believed to contribute to the useful properties of PSZ via a form of precipitation hardening. These precipitates initially form as tetragonal ZrO 2 , with a habit plane parallel to the brace 100 brace matrix planes. The orientation relations between the tetragonal precipitates and the cubic matrix are brace 100 brace/sub matrix/ 2 parallel brace 100 brace /sub precipitate/ or (001)/sub precipitate/ and broken bracket 100 broken bracket/sub matrix/ 2 parallel broken bracket 100 broken bracket/sub precipitate/ or [001]/sub precipitate/. (U.S.)

  6. Partial dynamical systems, fell bundles and applications

    CERN Document Server

    Exel, Ruy

    2017-01-01

    Partial dynamical systems, originally developed as a tool to study algebras of operators in Hilbert spaces, has recently become an important branch of algebra. Its most powerful results allow for understanding structural properties of algebras, both in the purely algebraic and in the C*-contexts, in terms of the dynamical properties of certain systems which are often hiding behind algebraic structures. The first indication that the study of an algebra using partial dynamical systems may be helpful is the presence of a grading. While the usual theory of graded algebras often requires gradings to be saturated, the theory of partial dynamical systems is especially well suited to treat nonsaturated graded algebras which are in fact the source of the notion of "partiality". One of the main results of the book states that every graded algebra satisfying suitable conditions may be reconstructed from a partial dynamical system via a process called the partial crossed product. Running in parallel with partial dynamica...

  7. Partial pressure (or fugacity) of carbon dioxide, salinity and other variables collected from time series observations using Bubble type equilibrator for autonomous carbon dioxide (CO2) measurement, Carbon dioxide (CO2) gas analyzer and other instruments from TIME_SERIES_BATS_1994_1996 in the North Atlantic Ocean from 1994-01-01 to 1996-12-31 (NCEI Accession 0157610)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0157610 includes chemical, meteorological, physical and time series data collected from TIME_SERIES_BATS_1994_1996 in the North Atlantic Ocean from...

  8. Coke from partially briquetted preheated coal mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Belitskii, A.N.; Sklyar, M.G.; Toryanik, Eh.I.; Bronshtein, A.P.

    1988-07-01

    Analyzes effects of partial coal charge briquetting on coking and on quality of coke for metallurgy. Effects of mixing hot coal briquets on temperature and moisture of coal were investigated on an experimental scale in a coking plant. Coal with a moisture content of 12% was used. Coking mixture consisted of 30% briquets and 70% crushed coal. Fifteen minutes after briquet mixing with coal, the mean coal charge temperature increased to 100-105 C and moisture content was lower than 2-5%. Results of laboratory investigations were verified by tests on a commercial scale. Experiments showed briquetting of weakly caking or non-caking coal charge components to be an efficient way of preventing coke quality decline. Adding 15-20% briquets consisting of weakly caking coal did not influence coke quality. Mixing hot coal briquets reduced moisture content in crushed coal, increased its temperature and reduced coking time.

  9. Partial radiative capture of resonance neutrons

    International Nuclear Information System (INIS)

    Samour, C.

    1969-01-01

    The radiative capture of resonance neutrons has been studied near the Saclay linac between 0.5 and 700 eV with time-of-flight method and a Ge(Li) detector. 195 Pt + n and 183 W + n allow the study of the distribution of partial radiative widths and their eventual correlation and also the variation of γ i > with E γ . The mean values of Ml and El transition intensities are compared in several tin isotopes. Interference effects, either between resonances or between direct capture and resonant capture are found in 195 Pt + n, 197 Au + n and 59 Co + n. The excited level schemes of a great deal of nuclei are obtained and compared with theoretical predictions. This study has been completed by an analysis of thermal spectrum. (author) [fr

  10. Prediction uncertainty in seasonal partial duration series

    DEFF Research Database (Denmark)

    Rasmussen, Peter Funder; Rosbjerg, Dan

    1991-01-01

    In order to obtain a good description of the exceedances in a partial duration series it is often necessary to divide the year into a number (2-4) of seasons. Hereby a stationary exceedance distribution can be maintained within each season. This type of seasonal models may, however, not be suitable...... for prediction purposes due to the large number of parameters required. In the particular case with exponentially distributed exceedances and Poissonian occurrence times the precision of the T year event estimator has been thoroughly examined considering both seasonal and nonseasonal models. The two......-seasonal probability density function of the T year event estimator has been deduced and used in the assessment of the precision of approximate moments. The nonseasonal approach covered both a total omission of seasonality by pooling data from different flood seasons and a discarding of nonsignificant season(s) before...

  11. Hemophilie A et B: a propos de dix cas colliges a Lome (Togo ...

    African Journals Online (AJOL)

    E Padaro, I.M.D. Kueviakoe, K.J. Guedenon, H Magnang, K Mawussi, Y Layibo, ... and paraclinical (partial thromboplastin time Activator and assay of factors VIII and IX). ... Six patients (60%) had hemophilia A and 4 (40%) hemophilia B. Seven ...

  12. Comparison of coagulation activity tests in vitro for selected biomaterials

    NARCIS (Netherlands)

    van Oeveren, W; Haan, J; Lagerman, P; Schoen, T

    Testing of coagulation induced by external communicating medical devices is an International Standardisation Organization (ISO) requirement for products exposed to human blood. Four categories of tests are indicated by ISO 10993/4: a clotting test (partial thromboplastin time; PTT), thrombin

  13. Interference from lupus anticoagulant on von Willebrand factor measurement in splenic marginal zone lymphoma

    DEFF Research Database (Denmark)

    Vinholt, Pernille J; Nybo, Mads

    2015-01-01

    We present a case concerning a patient with splenic marginal zone lymphoma (SMZL) and isolated prolonged activated partial thromboplastin time (aPTT) caused by lupus anticoagulant. Von Willebrand factor (VWF) activity and antigen were immeasurable by latex particle immunoturbidimetric assays...

  14. Abnormal peri-operative haemorrhage in asymptomatic patients is ...

    African Journals Online (AJOL)

    Accordingly, we undertook two studies to detertnine whether it could be justified in patients without a history of abnormal bleeding. In the first of these, 45 of 159 patients were excluded because of aspirin ingestion and a further 3 because of positive bleeding history so that prothrombin time, activated partial thromboplastin ...

  15. ADENOIDECTOMY/TONSILLECTOMY – Is the Clotting Profile ...

    African Journals Online (AJOL)

    Dr. Paul Adekunle Onakoya

    findings that could suggest bleeding disorders, values of prothrombin/activated partial thromboplastin time and ... history, complete blood count, platelet level and .... References. 1. Hartnick CJ, Ruben RJ. Preoperative coagulation studies prior to tonsillectomy. Arch Otolaryngol. Head Neck Surg 2000; 126: 684 – 688. 2.

  16. The Study of Hemolysis Effects on Coagulation Parameters

    African Journals Online (AJOL)

    and activated partial thromboplastin time (aPTT) testing, states that samples ... two groups of healthy donors and patient population. ... The second group was selected from the samples, ... [10] The presence or absence ... These conditions are not dependent upon .... Favaloro EJ, Funk DM, Lippi G. Pre‑analytical variables.

  17. TORCH Test

    Science.gov (United States)

    ... Parietal Cell Antibody Partial Thromboplastin Time (PTT, aPTT) Parvovirus B19 Pericardial Fluid Analysis Peritoneal Fluid Analysis Pertussis Tests ... enterovirus, Epstein-Barr virus , varicella-zoster virus , and parvovirus B19 . How is the sample collected for testing? A ...

  18. Plasma lipids and prothrombin time in rats fed palm oil and other commonly used fats in Egypt

    Directory of Open Access Journals (Sweden)

    Hussein, Mona M.

    1993-02-01

    Full Text Available Sprague-Dawley rats were fed for a total period of 8 weeks on six diets that were different in the source of their fat content. The fat content was provided either, palm oil or palm olein or corn oil or hydrogenated fat, or frying palm oil and mixture of corn oil + hydrogenated fat in the ratio (1:1. The latter was given to the control group. Animals fed these various experimental diets showed statistically significant differences in serum cholesterol and serum triglycerides content among all group. Increased HDL-cholesterol content was evident in animals fed on palm-olein and palm oil. The frying oil fed group showed lowest HDL-cholesterol content. In these experiments palm olein fed animals showed highest ratio of HDL-cholesterol to total cholesterol while the lowest ratio was shown in rats fed on frying oil. Prothrombin (PT and activated partial thromboplastin time (PTT showed higher values In palm oil, palm olein and corn oil diets as compared to all groups with each other.

    Ratas Sprague-Dawley fueron alimentadas durante un periodo total de 8 semanas con seis dietas diferentes en su contenido graso. El contenido graso fue proporcionado por aceite de palma u oleína de palma o aceite de maíz o grasa hidrogenada o aceite de palma de fritura y mezcla de aceite de maíz + grasa hidrogenada en la relación (1:1. El último fue dado al grupo de control. Los animales alimentados con las diferentes dietas experimentales mostraron diferencias significativas estadísticamente en el contenido en colesterol y triglicéridos en suero entre todos los grupos. El aumento en contenido HDL-colesterol fue evidente en animales alimentados con oleína de palma y aceite de palma. El grupo alimentado con aceite de fritura mostró el más bajo contenido en HDL-colesterol. En estos experimentos, los animales alimentados con oleína de palma mostraron la mayor relación de HDL-colesterol a colesterol total, mientras que la relación más baja fue mostrada

  19. Convergence of hybrid methods for solving non-linear partial ...

    African Journals Online (AJOL)

    This paper is concerned with the numerical solution and convergence analysis of non-linear partial differential equations using a hybrid method. The solution technique involves discretizing the non-linear system of PDE to obtain a corresponding non-linear system of algebraic difference equations to be solved at each time ...

  20. Characterization of partially purified catalase from camel ( Camelus ...

    African Journals Online (AJOL)

    The liver of camel has high level of catalase (32,225 units/g tissue) as commercially used bovine liver catalase. For the establishment of the enzyme, the rate of catalase activity was linearly increased with increase of the catalase concentration and incubation time. The procedure of partial purification of catalase from camel ...

  1. Identification of partial blockages in pipelines using genetic algorithms

    Indian Academy of Sciences (India)

    A methodology to identify the partial blockages in a simple pipeline using genetic algorithms for non-harmonic flows is presented in this paper. A sinusoidal flow generated by the periodic on-and-off operation of a valve at the outlet is investigated in the time domain and it is observed that pressure variation at the valve is ...

  2. Towards a simple method of analysis for partially prestressed concrete

    NARCIS (Netherlands)

    Bruggeling, A.S.G.

    1983-01-01

    This report examines the question whether, and to what extent, it is possible to leave the time-dependent effects out of account in the analysis of partially prestressed concrete, at least in so far as they relate to the redistribution of the stresses over the cross-section.

  3. Application of sugarcane bagasse ash as a partial cement ...

    African Journals Online (AJOL)

    Sugarcane bagasse ash is a byproduct of sugar factories found after burning sugarcane ... making materials especially cement, resulting in an increase in price. ... advantages can also be exploited by using bagasse ash as a partial cement ... Normal consistency, Setting time, Compressive strength, Water penetration depth.

  4. Simulation assessment of continuous simulating moving bed chromatography process with partial feed and new strategy with partial feed

    Directory of Open Access Journals (Sweden)

    H. Khan

    2009-09-01

    Full Text Available Partial Feed simulating moving bed (SMB has proved to be more efficient in binary separation performance (purity, recovery, productivity because of its two additional degrees of freedom, namely feed length and feed time, as compared to classical SMB process. The binary separation of dextran T6 and fructose with linear isotherm is modeled with Aspen Chromatography simulator in a four zone SMB with one column per zone for both normal-feed and Partial Feed. Increase in number of feed length and feed time in the cycle plays a very important role in the separation performance with Partial Feed. In addition, the effect of mode of operation (early or late introduction of increase in number of feed length in the cycle on product purity and recovery is also investigated. Furthermore, the binary separation system is designed with the safety margin method and the optimum operating parameters for simulation are calculated with triangle theory. Finally, a new strategy with Partial Feed is developed, showing improved separation performance relative to the basic four-zone SMB with regard to extract stream purity and recovery. The results of the proposed study can served as a useful summary of Partial Feed operation.

  5. Experimental continuous-variable cloning of partial quantum information

    DEFF Research Database (Denmark)

    Sabuncu, Metin; Leuchs, Gerd; Andersen, Ulrik Lund

    2008-01-01

    The fidelity of a quantum transformation is strongly linked with the prior partial information of the state to be transformed. We illustrate this interesting point by proposing and demonstrating the superior cloning of coherent states with prior partial information. More specifically, we propose...... two simple transformations that under the Gaussian assumption optimally clone symmetric Gaussian distributions of coherent states as well as coherent states with known phases. Furthermore, we implement for the first time near-optimal state-dependent cloning schemes relying on simple linear optics...

  6. Convergence criteria for systems of nonlinear elliptic partial differential equations

    International Nuclear Information System (INIS)

    Sharma, R.K.

    1986-01-01

    This thesis deals with convergence criteria for a special system of nonlinear elliptic partial differential equations. A fixed-point algorithm is used, which iteratively solves one linearized elliptic partial differential equation at a time. Conditions are established that help foresee the convergence of the algorithm. Under reasonable hypotheses it is proved that the algorithm converges for such nonlinear elliptic systems. Extensive experimental results are reported and they show the algorithm converges in a wide variety of cases and the convergence is well correlated with the theoretical conditions introduced in this thesis

  7. Partially Adaptive STAP Algorithm Approaches to functional MRI

    Science.gov (United States)

    Huang, Lejian; Thompson, Elizabeth A.; Schmithorst, Vincent; Holland, Scott K.; Talavage, Thomas M.

    2010-01-01

    In this work, the architectures of three partially adaptive STAP algorithms are introduced, one of which is explored in detail, that reduce dimensionality and improve tractability over fully adaptive STAP when used in construction of brain activation maps in fMRI. Computer simulations incorporating actual MRI noise and human data analysis indicate that element space partially adaptive STAP can attain close to the performance of fully adaptive STAP while significantly decreasing processing time and maximum memory requirements, and thus demonstrates potential in fMRI analysis. PMID:19272913

  8. Partial Path Column Generation for the Vehicle Routing Problem

    DEFF Research Database (Denmark)

    Jepsen, Mads Kehlet; Petersen, Bjørn

    This paper presents a column generation algorithm for the Capacitated Vehicle Routing Problem (CVRP) and the Vehicle Routing Problem with Time Windows (VRPTW). Traditionally, column generation models of the CVRP and VRPTW have consisted of a Set Partitioning master problem with each column...... of the giant tour’; a so-called partial path, i.e., not necessarily starting and ending in the depot. This way, the length of the partial path can be bounded and a better control of the size of the solution space for the pricing problem can be obtained....

  9. The origin of the concept of partial epilepsy.

    Science.gov (United States)

    Eadie

    1999-03-01

    The International League Against Epilepsy has devised classifications which subdivide both epileptic seizures and the epilepsies and epileptic syndromes into two main types: generalized and partial. Epileptogenesis in the partial variety is believed to originate in a localized part of the cerebral cortex and results in clinical manifestations which appear to commence in only a restricted part of the sufferer's body. Use of the term 'partial' in relation to these entities has often been said to date back to James Cowles Prichard (1786-1849) who was the author of the second major work on epilepsy to be written in the UK. While Prichard certainly described 'partial epilepsy', he stated that he intended the words to refer to the fact that the disorder he described under that designation was only partly, and not fully, epileptic in nature. He did not refer to the fact that it affected only part of the body as his basis for using the term. In the absence of knowledge of localization of function in the cerebral cortex at Prichard's time of writing, he had no basis for deducing that the underlying epileptic process arose in only part of the brain. However, there is an earlier mention of the use of the word 'partial' in relation to epilepsy. This is to be found in the writings of the great Scottish physician William Cullen (1710-1790), and there is reason to believe that Prichard should have been aware of this. Cullen used 'partial' with an intention similar to the modern one, employing the word to refer to seizures which affected only part of the body. Credit for the origin of the idea of a 'partial' epilepsy should belong to Cullen; not only did he have priority over Prichard but his concept was closer to the modern one than was Prichard's. Copyright 1999 Harcourt Publishers Ltd.

  10. Partial differential equations of mathematical physics

    CERN Document Server

    Sobolev, S L

    1964-01-01

    Partial Differential Equations of Mathematical Physics emphasizes the study of second-order partial differential equations of mathematical physics, which is deemed as the foundation of investigations into waves, heat conduction, hydrodynamics, and other physical problems. The book discusses in detail a wide spectrum of topics related to partial differential equations, such as the theories of sets and of Lebesgue integration, integral equations, Green's function, and the proof of the Fourier method. Theoretical physicists, experimental physicists, mathematicians engaged in pure and applied math

  11. [Removable partial dentures. Oral functions and types

    OpenAIRE

    Creugers, N.H.J.; Baat, C. de

    2009-01-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combinatio...

  12. Partial vaginismus : definition, symptoms and treatment

    OpenAIRE

    Engman, Maria

    2007-01-01

    Vaginismus is a sexual pain disorder, where spasm of musculature of the outer third of the vagina interferes with intercourse. Vaginismus exists in two forms: total vaginismus, where intercourse is impossible, and the more seldom described partial vaginismus, in which intercourse is possible but painful. The aim of the thesis was to develop a useful definition of partial vaginismus for both clinical and scientific purposes; to describe the prevalence of partial vaginismus among women with sup...

  13. Partial Evaluation of the Euclidian Algorithm

    DEFF Research Database (Denmark)

    Danvy, Olivier; Goldberg, Mayer

    1997-01-01

    -like behavior. Each of them presents a challenge for partial evaluation. The Euclidian algorithm is one of them, and in this article, we make it amenable to partial evaluation. We observe that the number of iterations in the Euclidian algorithm is bounded by a number that can be computed given either of the two...... arguments. We thus rephrase this algorithm using bounded recursion. The resulting program is better suited for automatic unfolding and thus for partial evaluation. Its specialization is efficient....

  14. Partial distance correlation with methods for dissimilarities

    OpenAIRE

    Székely, Gábor J.; Rizzo, Maria L.

    2014-01-01

    Distance covariance and distance correlation are scalar coefficients that characterize independence of random vectors in arbitrary dimension. Properties, extensions, and applications of distance correlation have been discussed in the recent literature, but the problem of defining the partial distance correlation has remained an open question of considerable interest. The problem of partial distance correlation is more complex than partial correlation partly because the squared distance covari...

  15. A Novel Partial Differential Algebraic Equation (PDAE) Solver

    DEFF Research Database (Denmark)

    Lim, Young-il; Chang, Sin-Chung; Jørgensen, Sten Bay

    2004-01-01

    For solving partial differential algebraic equations (PDAEs), the space-time conservation element/solution element (CE/SE) method is addressed in this study. The method of lines (MOL) using an implicit time integrator is compared with the CE/SE method in terms of computational efficiency, solution...... or nonlinear adsorption isotherm are solved by the two methods. The CE/SE method enforces both local and global flux conservation in space and time, and uses a simple stencil structure (two points at the previous time level and one point at the present time level). Thus, accurate and computationally...

  16. Prefabricated light-polymerizing plastic pattern for partial denture framework

    Directory of Open Access Journals (Sweden)

    Atsushi Takaichi

    2011-01-01

    Full Text Available Our aim is to report an application of a prefabricated light-polymerizing plastic pattern to construction of removable partial denture framework without the use of a refractory cast. A plastic pattern for the lingual bar was adapted on the master cast of a mandibular Kennedy class I partially edentulous patient. The pattern was polymerized in a light chamber. Cobalt-chromium wires were employed to minimize the potential distortion of the plastic framework. The framework was carefully removed from the master cast and invested with phosphate-bonded investment for the subsequent casting procedures. A retentive clasp was constructed using 19-gauge wrought wire and was welded to the framework by means of laser welding machine. An excellent fit of the framework in the patient′s mouth was observed in the try-in and the insertion of the denture. The result suggests that this method minimizes laboratory cost and time for partial denture construction.

  17. A fast exact sequential algorithm for the partial digest problem.

    Science.gov (United States)

    Abbas, Mostafa M; Bahig, Hazem M

    2016-12-22

    Restriction site analysis involves determining the locations of restriction sites after the process of digestion by reconstructing their positions based on the lengths of the cut DNA. Using different reaction times with a single enzyme to cut DNA is a technique known as a partial digestion. Determining the exact locations of restriction sites following a partial digestion is challenging due to the computational time required even with the best known practical algorithm. In this paper, we introduce an efficient algorithm to find the exact solution for the partial digest problem. The algorithm is able to find all possible solutions for the input and works by traversing the solution tree with a breadth-first search in two stages and deleting all repeated subproblems. Two types of simulated data, random and Zhang, are used to measure the efficiency of the algorithm. We also apply the algorithm to real data for the Luciferase gene and the E. coli K12 genome. Our algorithm is a fast tool to find the exact solution for the partial digest problem. The percentage of improvement is more than 75% over the best known practical algorithm for the worst case. For large numbers of inputs, our algorithm is able to solve the problem in a suitable time, while the best known practical algorithm is unable.

  18. [Cytogenetic and molecular genetic diagnosis of a neonate with partial 13q trisomy and partial 5p monosomy].

    Science.gov (United States)

    Xiao, Wenjun; Gao, Zhenkui; Meng, Qian; Zhang, Man

    2014-12-01

    To diagnose a neonate presenting with multiple dysmorphic features, Cri-du-chat signs and hypoglycemia and to correlate the phenotype with the genotype. The patient was diagnosed with conventional cytogenetics and real-time fluorescence quantitative PCR (QF-PCR). The phenotype was then correlated with the genotype through a review of literature. The neonate was diagnosed with a partial 13q trisomy (q12 → qter) and partial 5p monosomy (p15 →pter). A rare diagnosis has been established with combined cytogenetic and molecular genetic techniques. QF-PCR has a broad application in genetic diagnosis.

  19. Unconditionally stable difference methods for delay partial differential equations

    OpenAIRE

    Huang, Chengming; Vandewalle, Stefan

    2012-01-01

    This paper is concerned with the numerical solution of parabolic partial differential equations with time-delay. We focus in particular on the delay dependent stability analysis of difference methods that use a non-constrained mesh, i.e., the time step-size is not required to be a submultiple of the delay. We prove that the fully discrete system unconditionally preserves the delay dependent asymptotic stability of the linear test problem under consideration, when the following discretizati...

  20. Asymptotic problems for stochastic partial differential equations

    Science.gov (United States)

    Salins, Michael

    Stochastic partial differential equations (SPDEs) can be used to model systems in a wide variety of fields including physics, chemistry, and engineering. The main SPDEs of interest in this dissertation are the semilinear stochastic wave equations which model the movement of a material with constant mass density that is exposed to both determinstic and random forcing. Cerrai and Freidlin have shown that on fixed time intervals, as the mass density of the material approaches zero, the solutions of the stochastic wave equation converge uniformly to the solutions of a stochastic heat equation, in probability. This is called the Smoluchowski-Kramers approximation. In Chapter 2, we investigate some of the multi-scale behaviors that these wave equations exhibit. In particular, we show that the Freidlin-Wentzell exit place and exit time asymptotics for the stochastic wave equation in the small noise regime can be approximated by the exit place and exit time asymptotics for the stochastic heat equation. We prove that the exit time and exit place asymptotics are characterized by quantities called quasipotentials and we prove that the quasipotentials converge. We then investigate the special case where the equation has a gradient structure and show that we can explicitly solve for the quasipotentials, and that the quasipotentials for the heat equation and wave equation are equal. In Chapter 3, we study the Smoluchowski-Kramers approximation in the case where the material is electrically charged and exposed to a magnetic field. Interestingly, if the system is frictionless, then the Smoluchowski-Kramers approximation does not hold. We prove that the Smoluchowski-Kramers approximation is valid for systems exposed to both a magnetic field and friction. Notably, we prove that the solutions to the second-order equations converge to the solutions of the first-order equation in an Lp sense. This strengthens previous results where convergence was proved in probability.

  1. Partial discharges and bulk dielectric field enhancement

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Johansson, Torben

    2000-01-01

    A consequence of partial discharge activity within a gaseous void is the production of a field enhancement in the solid dielectric in the proximity of the void. This situation arises due to the charge created by the partial discharges accumulating at the void wall. The influence of the spatial...

  2. Laparoscopic partial nephrectomy for endophytic hilar tumors

    DEFF Research Database (Denmark)

    Di Pierro, G B; Tartaglia, N; Aresu, L

    2014-01-01

    To analyze feasibility and outcomes of laparoscopic partial nephrectomy (LPN) for endophytic hilar tumors in low-intermediate (ASA I-II) risk patients.......To analyze feasibility and outcomes of laparoscopic partial nephrectomy (LPN) for endophytic hilar tumors in low-intermediate (ASA I-II) risk patients....

  3. Removable partial overdentures for the irradiated patient

    International Nuclear Information System (INIS)

    Rosenberg, S.W.

    1990-01-01

    Patients who have received radiotherapy to the head and neck area must avoid dental extractions and seek simplicity in treatment and home care follow-up. For partially edentulous patients, removable partial overdenture therapy can fulfill these goals while maintaining the high level of function and aesthetics desired by patients.11 references

  4. Coordinating choice in partial cooperative equilibrium

    NARCIS (Netherlands)

    Mallozzi, L.; Tijs, S.H.

    2009-01-01

    In this paper we consider symmetric aggregative games and investigate partial cooperation between a portion of the players that sign a cooperative agreement and the rest of the players. Existence results of partial cooperative equilibria are obtained when the players who do not sign the agreement

  5. Memoization in Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Balat, Vincent; Danvy, Olivier

    2002-01-01

    the functions and type-directed partial evaluation provides a convenient setting to obtain the normal form of their composition. However, off-the-shelf type-directed partial evaluation turns out to yield gigantic normal forms. We identify that this gigantism is due to redundancies, and that these redundancies...

  6. Mathematical Modelling of Intraretinal Oxygen Partial Pressure ...

    African Journals Online (AJOL)

    Purpose: The aim of our present work is to develop a simple steady state model for intraretinal oxygen partial pressure distribution and to investigate the effect of various model parameters on the partial pressure distribution under adapted conditions of light and darkness.. Method: A simple eight-layered mathematical model ...

  7. Zero ischemia laparoscopic partial thulium laser nephrectomy.

    LENUS (Irish Health Repository)

    Thomas, Arun Z

    2013-11-01

    Laser technology presents a promising alternative to achieve tumor excision and renal hemostasis with or without hilar occlusion, yet its use in partial nephrectomy has not been significantly evaluated. We prospectively evaluated the thulium:yttrium-aluminum-garnet laser in laparoscopic partial nephrectomy (LPN) in our institution over a 1-year period.

  8. Esthetic Rehabilitation with a Cast Partial Denture

    Directory of Open Access Journals (Sweden)

    Suraksha Shrestha

    2017-01-01

    Full Text Available Removable partial denture is a treatment option where fixed prosthesis is not indicated. Due to its esthetic problems in the anterior region various modifications have been designed for its fabrication. This article describes an esthetic alternative using a round rest distal depression clasp for maxillary anterior teeth abutment while restoring the missing teeth with a cast partial denture.

  9. Heat deposition on the partial limiter

    International Nuclear Information System (INIS)

    Itoh, Kimitaka; Itoh, Sanae-I; Nagasaki, Kazunobu.

    1990-01-01

    The effect of the partial limiter in the outermost magnetic surface of toroidal plasmas is studied. The power deposition on the partial limiter and its effect on the temperature profile are analysed. Interpretation in terms of the perpendicular heat conductivity is also discussed. (author)

  10. Partial purification and biochemical characterization of acid ...

    African Journals Online (AJOL)

    Mung bean (Vigna radiata) is one of the important crops of the North Eastern Region of India. In the present study, acid phosphatase enzyme was isolated and partially purified from germinated local mung bean seeds. The sequential partial purification process was performed using ammonium sulphate precipitation method.

  11. Partial Safety Factors for Rubble Mound Breakwaters

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Burcharth, H. F.; Christiani, E.

    1995-01-01

    On the basis of the failure modes formulated in the various subtasks calibration of partial safety factors are described in this paper. The partial safety factors can be used to design breakwaters under quite different design conditions, namely probabilities of failure from 0.01 to 0.4, design...... lifetimes from 20 to 100 years and different qualities of wave data. A code of practice where safety is taken into account using partial safety factors is called a level I code. The partial safety factors are calibrated using First Order Reliability Methods (FORM, see Madsen et al. [1]) where...... in section 3. First Order Reliability Methods are described in section 4, and in section 5 it is shown how partial safety factors can be introduced and calibrated. The format of a code for design and analysis of rubble mound breakwaters is discussed in section 6. The mathematical formulation of the limit...

  12. Development of Partial Discharging Simulation Test Equipment

    Science.gov (United States)

    Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu

    2017-12-01

    In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.

  13. LazySorted: A Lazily, Partially Sorted Python List

    Directory of Open Access Journals (Sweden)

    Naftali Harris

    2015-06-01

    Full Text Available LazySorted is a Python C extension implementing a partially and lazily sorted list data structure. It solves a common problem faced by programmers, in which they need just part of a sorted list, like its middle element (the median, but sort the entire list to get it. LazySorted presents them with the abstraction that they are working with a fully sorted list, while actually only sorting the list partially with quicksort partitions to return the requested sub-elements. This enables programmers to use naive "sort first" algorithms but nonetheless attain linear run-times when possible. LazySorted may serve as a drop-in replacement for the built-in sorted function in most cases, and can sometimes achieve run-times more than 7 times faster.

  14. Microlaparoscopic technique for partial salpingectomy using bipolar electrocoagulation.

    Science.gov (United States)

    Siegle, J C; Cartmell, L W; Rayburn, W F

    2001-07-01

    To describe a technique of performing a partial salpingectomy using a small-diameter (2-mm) laparoscope and bipolar electrocoagulation. Sixty consecutive women desiring permanent sterilization underwent laparoscopic partial salpingectomy using a 2-mm transumbilical laparoscope and secondary midline sites suprapubically and midway above the pubis. A midportion of the tube was coagulated using Kleppinger forceps, transected with scissors and removed using grasping forceps. Additional time to remove both coagulated tubal segments averaged 4 minutes (range, 3-10). Each segment (mean, 1.5 cm; range, 0.9-2.4 cm) was confirmed in the operating room, then histologically. The transected tubal edges were separated with no thermal injury to nearby structures and with no mesosalpingeal hemorrhage. No cases required conversion from microlaparoscopy to a traditional method, and recovery time was not prolonged. The puncture sites healed well without sutures. Successful removal of electrocoagulated tubal segments with histologic confirmation was undertaken microlaparoscopically, with minimal additional operative time.

  15. Partially Observed Mixtures of IRT Models: An Extension of the Generalized Partial-Credit Model

    Science.gov (United States)

    Von Davier, Matthias; Yamamoto, Kentaro

    2004-01-01

    The generalized partial-credit model (GPCM) is used frequently in educational testing and in large-scale assessments for analyzing polytomous data. Special cases of the generalized partial-credit model are the partial-credit model--or Rasch model for ordinal data--and the two parameter logistic (2PL) model. This article extends the GPCM to the…

  16. Catalytic partial oxidation of pyrolysis oils

    Science.gov (United States)

    Rennard, David Carl

    2009-12-01

    This thesis explores the catalytic partial oxidation (CPO) of pyrolysis oils to syngas and chemicals. First, an exploration of model compounds and their chemistries under CPO conditions is considered. Then CPO experiments of raw pyrolysis oils are detailed. Finally, plans for future development in this field are discussed. In Chapter 2, organic acids such as propionic acid and lactic acid are oxidized to syngas over Pt catalysts. Equilibrium production of syngas can be achieved over Rh-Ce catalysts; alternatively mechanistic evidence is derived using Pt catalysts in a fuel rich mixture. These experiments show that organic acids, present in pyrolysis oils up to 25%, can undergo CPO to syngas or for the production of chemicals. As the fossil fuels industry also provides organic chemicals such as monomers for plastics, the possibility of deriving such species from pyrolysis oils allows for a greater application of the CPO of biomass. However, chemical production is highly dependent on the originating molecular species. As bio oil comprises up to 400 chemicals, it is essential to understand how difficult it would be to develop a pure product stream. Chapter 3 continues the experimentation from Chapter 2, exploring the CPO of another organic functionality: the ester group. These experiments demonstrate that equilibrium syngas production is possible for esters as well as acids in autothermal operation with contact times as low as tau = 10 ms over Rh-based catalysts. Conversion for these experiments and those with organic acids is >98%, demonstrating the high reactivity of oxygenated compounds on noble metal catalysts. Under CPO conditions, esters decompose in a predictable manner: over Pt and with high fuel to oxygen, non-equilibrium products show a similarity to those from related acids. A mechanism is proposed in which ethyl esters thermally decompose to ethylene and an acid, which decarbonylates homogeneously, driven by heat produced at the catalyst surface. Chapter 4

  17. [Routine oral examinations and specific after-care for removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Keltjens, H M A M; Creugers, N H J

    2011-01-01

    Following treatment with a removable partial denture, routine oral examinations are required to stabilize the existing condition in a sustainable way and to make possible the timely treatment of anomalies which have appeared. In cases of problems assessed during a routine oral examination in relation to the removable partial dentures, maintenance, restorative and prosthetic treatment may be indicated. Maintenance treatments are indicated for small and easily retrievable alterations. In removable partial denture treatment, adequate space between prepared tooth and denture is essential. Possible prosthetic treatments of a removable partial denture are relining, rebasing, improving or renewing the maxillomandibular relation, repairment, and extension.

  18. Hydraulic behaviour of a partially uncovered core

    International Nuclear Information System (INIS)

    Fischer, K.; Hafner, W.

    1989-10-01

    A critical review of experimental data and theoretical models relevant to the thermohydraulic processes in a partially uncovered core has been performed. Presently available optimized thermohydraulic codes should be able to predict swell level elevations within an error band of ± 0.5 m. Rod temperature rising velocities could be predicted within an error bandwidth of ± 10%, provided the correct rod heat capacity is given. A general statement about the accuracy of predicted rod temperatures is not possible because the errors increase with simulation time. Highest errors are expected for long transients with low heating rates and low steam velocities. As a result, three areas for additional research are suggested: - a high-pressure test at 120 bar to complete the void correlation data base, - a low steam flow - low power experiment to improve heat transfer correlations, - a numerical investigation of three-dimensional effects in the reactor core with unequally heated rod bundles. For the present state of 1-dimensional experiments and models, suggestions for a satisfactory modeling have been derived. The suggested further work could improve the modelling capabilities and the code reliability for some limiting cases like high pressure boil-off, low-power long-term steam cooling, and unequal heating of neighbouring bundles considerably

  19. Partial observation control in an anticipating environment

    International Nuclear Information System (INIS)

    Oeksendal, B; Sulem, A

    2004-01-01

    A study is made of a controlled stochastic system whose state X(t) at time t is described by a stochastic differential equation driven by Levy processes with filtration {F t } telementof[0,T] . The system is assumed to be anticipating, in the sense that the coefficients are assumed to be adapted to a filtration {G t } t≥0 with F t subset of equal G t for all t element of [0,T]. The corresponding anticipating stochastic differential equation is interpreted in the sense of forward integrals, which naturally generalize semimartingale integrals. The admissible controls are assumed to be adapted to a filtration {E t } telementof[0,T] such that E t subset of equal F t for all t element of [0,T]. The general problem is to maximize a given performance functional of this system over all admissible controls. This is a partial observation stochastic control problem in an anticipating environment. Examples of applications include stochastic volatity models in finance, insider influenced financial markets, and stochastic control of systems with delayed noise effects. Some particular cases in finance, involving optimal portfolios with logarithmic utility, are solved explicitly

  20. Precise Point Positioning with Partial Ambiguity Fixing.

    Science.gov (United States)

    Li, Pan; Zhang, Xiaohong

    2015-06-10

    Reliable and rapid ambiguity resolution (AR) is the key to fast precise point positioning (PPP). We propose a modified partial ambiguity resolution (PAR) method, in which an elevation and standard deviation criterion are first used to remove the low-precision ambiguity estimates for AR. Subsequently the success rate and ratio-test are simultaneously used in an iterative process to increase the possibility of finding a subset of decorrelated ambiguities which can be fixed with high confidence. One can apply the proposed PAR method to try to achieve an ambiguity-fixed solution when full ambiguity resolution (FAR) fails. We validate this method using data from 450 stations during DOY 021 to 027, 2012. Results demonstrate the proposed PAR method can significantly shorten the time to first fix (TTFF) and increase the fixing rate. Compared with FAR, the average TTFF for PAR is reduced by 14.9% for static PPP and 15.1% for kinematic PPP. Besides, using the PAR method, the average fixing rate can be increased from 83.5% to 98.2% for static PPP, from 80.1% to 95.2% for kinematic PPP respectively. Kinematic PPP accuracy with PAR can also be significantly improved, compared to that with FAR, due to a higher fixing rate.

  1. Influence of habitat and number of nestlings on partial brood loss in red-cockaded woodpeckers

    Science.gov (United States)

    James R. McCormick; Richard N. Conner; D. Brent Burt; Daniel Saenz

    2004-01-01

    Partial brood loss in red-cockaded woodpeckers (Picoides borealis) was studied during 2 breeding seasons in eastern Texas. The timing of partial brood loss, group size, number of initial nestlings, number of birds fledged, and habitat characteristics of the group's cavity-tree cluster were examined for 37 woodpecker groups in loblolly- (

  2. Robot-assisted laparoscopic partial nephrectomy: Current review of the technique and literature.

    Science.gov (United States)

    Singh, Iqbal

    2009-10-01

    To visit the operative technique and to review the current published English literature on the technique, and outcomes following robot-assisted laparoscopic partial nephrectomy (RPN). We searched the published English literature and the PubMed(()) for published series of 'robotic partial nephrectomy' (RPN) using the keywords; robot, robot-assisted laparoscopic partial nephrectomy, laparoscopic partial nephrectomy, partial nephrectomy and laparoscopic surgery. The search yielded 15 major selected series of 'robotic partial nephrectomy'; these were reviewed, tracked and analysed in order to determine the current status and role of RPN in the management of early renal neoplasm(s), as a minimally invasive surgical alternative to open partial nephrectomy. A review of the initial peri-operative outcome of the 350 cases of select series of RPN reported in published English literature revealed a mean operating time, warm ischemia time, estimated blood loss and hospital stay, of 191 minutes, 25 minutes, 162 ml and 2.95 days, respectively. The overall computed mean complication rate of RPN in the present select series was about 7.4%. RPN is a safe, feasible and effective minimally invasive surgical alternative to laparoscopic partial nephrectomy for early stage (T(1)) renal neoplasm(s). It has acceptable initial renal functional outcomes without the increased risk of major complications in experienced hands. Prospective randomised, controlled, comparative clinical trials with laparoscopic partial nephrectomy (LPN) are the need of the day. While the initial oncological outcomes of RPN appear to be favourable, long-term data is awaited.

  3. Telescopic Partial Dentures-Concealed Technology.

    Science.gov (United States)

    Bhagat, Tushar Vitthalrao; Walke, Ashwini Nareshchandra

    2015-09-01

    The ideal goal of good dentist is to restore the missing part of oral structure, phonetics, his look and the most important is restored the normal health of the patient, which is hampered due to less or insufficient intake of food. Removable partial denture (RPD) treatment option is considered as a notion, which precludes the inevitability of "floating plastic" in edentulous mouth, that many times fail to fulfill the above essential of the patients. In modern dentistry, though the dental implants or fixed partial denture is the better options, but they have certain limitations. However, overdentures and particularly telescopic denture is the overlooked technology in dentistry that would be a boon for such needy patients. Telescopic denture is especially indicated in the distal edentulous area with minimum two teeth bilaterally present with a good amount of periodontal support. This treatment modality is sort of preventive prosthodontics remedy, which in a conservative manner preserve the remaining teeth and helps in conservation of alveolar bone ultimately. There are two tenets related to this option, one is constant conservation edentulous ridge around the retained tooth and the most important is the endless existence of periodontal sensory action that directs and monitor gnathodynamic task. In this option the primary coping or inner coping are cemented on the prepared tooth, and a similar removable outer or inner telescopic crown placed tightly by using a mechanism of tenso-friction, this is firmly attached to a removable RPD in place without moving or rocking of the prosthesis, which is the common compliant of almost all patients of RPD. Copings are also protecting the abutment from tooth decay and also offers stabilization and maintaining of the outer crown. The outer crown engages the inner coping and gives as an anchor for the remainder of the dentition. This work is the review of telescopic prosthesis which is well supported by the case discussion, and

  4. Partial transposition on bi-partite system

    OpenAIRE

    Han, Y. -J.; Ren, X. J.; Wu, Y. C.; Guo, G. -C.

    2006-01-01

    Many of the properties of the partial transposition are not clear so far. Here the number of the negative eigenvalues of K(T)(the partial transposition of K) is considered carefully when K is a two-partite state. There are strong evidences to show that the number of negative eigenvalues of K(T) is N(N-1)/2 at most when K is a state in Hilbert space N*N. For the special case, 2*2 system(two qubits), we use this result to give a partial proof of the conjecture sqrt(K(T))(T)>=0. We find that thi...

  5. Numerical Analysis of Partial Differential Equations

    CERN Document Server

    Lui, S H

    2011-01-01

    A balanced guide to the essential techniques for solving elliptic partial differential equations Numerical Analysis of Partial Differential Equations provides a comprehensive, self-contained treatment of the quantitative methods used to solve elliptic partial differential equations (PDEs), with a focus on the efficiency as well as the error of the presented methods. The author utilizes coverage of theoretical PDEs, along with the nu merical solution of linear systems and various examples and exercises, to supply readers with an introduction to the essential concepts in the numerical analysis

  6. Partial differential equations for scientists and engineers

    CERN Document Server

    Farlow, Stanley J

    1993-01-01

    Most physical phenomena, whether in the domain of fluid dynamics, electricity, magnetism, mechanics, optics, or heat flow, can be described in general by partial differential equations. Indeed, such equations are crucial to mathematical physics. Although simplifications can be made that reduce these equations to ordinary differential equations, nevertheless the complete description of physical systems resides in the general area of partial differential equations.This highly useful text shows the reader how to formulate a partial differential equation from the physical problem (constructing th

  7. Partial Deconvolution with Inaccurate Blur Kernel.

    Science.gov (United States)

    Ren, Dongwei; Zuo, Wangmeng; Zhang, David; Xu, Jun; Zhang, Lei

    2017-10-17

    Most non-blind deconvolution methods are developed under the error-free kernel assumption, and are not robust to inaccurate blur kernel. Unfortunately, despite the great progress in blind deconvolution, estimation error remains inevitable during blur kernel estimation. Consequently, severe artifacts such as ringing effects and distortions are likely to be introduced in the non-blind deconvolution stage. In this paper, we tackle this issue by suggesting: (i) a partial map in the Fourier domain for modeling kernel estimation error, and (ii) a partial deconvolution model for robust deblurring with inaccurate blur kernel. The partial map is constructed by detecting the reliable Fourier entries of estimated blur kernel. And partial deconvolution is applied to wavelet-based and learning-based models to suppress the adverse effect of kernel estimation error. Furthermore, an E-M algorithm is developed for estimating the partial map and recovering the latent sharp image alternatively. Experimental results show that our partial deconvolution model is effective in relieving artifacts caused by inaccurate blur kernel, and can achieve favorable deblurring quality on synthetic and real blurry images.Most non-blind deconvolution methods are developed under the error-free kernel assumption, and are not robust to inaccurate blur kernel. Unfortunately, despite the great progress in blind deconvolution, estimation error remains inevitable during blur kernel estimation. Consequently, severe artifacts such as ringing effects and distortions are likely to be introduced in the non-blind deconvolution stage. In this paper, we tackle this issue by suggesting: (i) a partial map in the Fourier domain for modeling kernel estimation error, and (ii) a partial deconvolution model for robust deblurring with inaccurate blur kernel. The partial map is constructed by detecting the reliable Fourier entries of estimated blur kernel. And partial deconvolution is applied to wavelet-based and learning

  8. Introduction to partial differential equations with applications

    CERN Document Server

    Zachmanoglou, E C

    1988-01-01

    This text explores the essentials of partial differential equations as applied to engineering and the physical sciences. Discusses ordinary differential equations, integral curves and surfaces of vector fields, the Cauchy-Kovalevsky theory, more. Problems and answers.

  9. Dual Component Removable Partial Denture shows improved ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-02-18

    Feb 18, 2009 ... 2Faculty of Dentistry, the University of Hong Kong, Hong Kong. 3Department of ... an example of poor oral condition caused mainly by periodontitis, and ... working model of the Dual Component Removable Partial Denture.

  10. chemical composition and sensory acceptability of partially ...

    African Journals Online (AJOL)

    Pasta products were produced from partially gelatinized blends of wheat, ... products were significantly different in height, thickness and expansion ratio but, not significantly different ... protein and no less than 30% of wet gluten (protein.

  11. Hospital Outpatient PPS Partial Hospitalization Program LDS

    Data.gov (United States)

    U.S. Department of Health & Human Services — Hospital Outpatient Prospective Payment System (OPPS) Partial Hospitalization Program LDS This file contains select claim level data and is derived from 2010 claims...

  12. On construction of partial association rules

    KAUST Repository

    Moshkov, Mikhail; Piliszczuk, Marcin; Zielosko, Beata Marta

    2009-01-01

    This paper is devoted to the study of approximate algorithms for minimization of partial association rule length. It is shown that under some natural assumptions on the class NP, a greedy algorithm is close to the best polynomial approximate

  13. Partial Duplication of Chromosome 8p

    African Journals Online (AJOL)

    rme

    The partial chromosome 8p duplication is a rare syndrome and is ... abnormality of maternal origin that ... second trimester by vaginal bleeding and ... echocardiography, brain CT scan and. MRI. Fig. 1:Conventional karyotype of case 3 showing.

  14. Clustering stocks using partial correlation coefficients

    Science.gov (United States)

    Jung, Sean S.; Chang, Woojin

    2016-11-01

    A partial correlation analysis is performed on the Korean stock market (KOSPI). The difference between Pearson correlation and the partial correlation is analyzed and it is found that when conditioned on the market return, Pearson correlation coefficients are generally greater than those of the partial correlation, which implies that the market return tends to drive up the correlation between stock returns. A clustering analysis is then performed to study the market structure given by the partial correlation analysis and the members of the clusters are compared with the Global Industry Classification Standard (GICS). The initial hypothesis is that the firms in the same GICS sector are clustered together since they are in a similar business and environment. However, the result is inconsistent with the hypothesis and most clusters are a mix of multiple sectors suggesting that the traditional approach of using sectors to determine the proximity between stocks may not be sufficient enough to diversify a portfolio.

  15. Partial Actions, Paradoxicality and Topological full Groups

    DEFF Research Database (Denmark)

    Scarparo, Eduardo

    uniform Roe algebra is finite. In Article C, we analyze the C*-algebra generated by the Koopman representation of a topological full group, showing, in particular, that it is not AF andhas real rank zero. We also prove that if G is a finitely generated, elementary amenable group, and C*(G) has real rank......We study how paradoxicality properties affect the way groups partially acton topological spaces and C*-algebras. We also investigate the real rank zero and AF properties for certain classes of group C*-algebras. Specifically, in article A, we characterize supramenable groups in terms of existence...... of invariant probability measures for partial actions on compact Hausdorff spaces and existence of tracial states on partial crossed products. These characterizations show that, in general, one cannot decompose a partial crossed product of a C*-algebra by a semidirect product of groups as two iterated...

  16. Higher-order rewriting and partial evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier; Rose, Kristoffer H.

    1998-01-01

    We demonstrate the usefulness of higher-order rewriting techniques for specializing programs, i.e., for partial evaluation. More precisely, we demonstrate how casting program specializers as combinatory reduction systems (CRSs) makes it possible to formalize the corresponding program...

  17. Mathematical Modelling of Intraretinal Oxygen Partial Pressure

    African Journals Online (AJOL)

    Erah

    oxygen availability) is required for retinal oxidative metabolism. .... retina was described using Hill's equation and Fick's law. ... ganglion cell / nerve fiber layer and the superficial ..... parameter values producing the best. Figure 2: Partial ...

  18. Partial Differential Equations Modeling and Numerical Simulation

    CERN Document Server

    Glowinski, Roland

    2008-01-01

    This book is dedicated to Olivier Pironneau. For more than 250 years partial differential equations have been clearly the most important tool available to mankind in order to understand a large variety of phenomena, natural at first and then those originating from human activity and technological development. Mechanics, physics and their engineering applications were the first to benefit from the impact of partial differential equations on modeling and design, but a little less than a century ago the Schrödinger equation was the key opening the door to the application of partial differential equations to quantum chemistry, for small atomic and molecular systems at first, but then for systems of fast growing complexity. Mathematical modeling methods based on partial differential equations form an important part of contemporary science and are widely used in engineering and scientific applications. In this book several experts in this field present their latest results and discuss trends in the numerical analy...

  19. Impact of removable partial denture prosthesis on chewing efficiency

    Science.gov (United States)

    BESSADET, Marion; NICOLAS, Emmanuel; SOCHAT, Marine; HENNEQUIN, Martine; VEYRUNE, Jean-Luc

    2013-01-01

    Removable partial denture prostheses are still being used for anatomic, medical and economic reasons. However, the impact on chewing parameters is poorly described. Objectives The objective of this study was to estimate the impact of removable partial denture prosthesis on masticatory parameters. Material and Methods Nineteen removable partial denture prosthesis (RPDP) wearers participated in the study. Among them, 10 subjects were Kennedy Class III partially edentulous and 9 with posterior edentulism (Class I). All presented a complete and full dentate opposing arch. The subjects chewed samples of carrots and peanuts with and without their prosthesis. The granulometry of the expectorated boluses from carrot and peanuts was characterized by median particle size (D50), determined at the natural point of swallowing. Number of chewing cycles (CC), chewing time (CT) and chewing frequency (CF=CC/CT) were video recorded. Results With RPDP, the mean D50 values for carrot and peanuts were lower [Repeated Model Procedures (RMP), F=15, p<0.001] regardless of the type of Kennedy Class. For each food, mean CC, CT and CF values recorded decreased (RMP, F=18, F=9, and F=20 respectively, p<0.01). With or without RPD, the boluses' granulometry values were above the masticatory normative index (MNI) determined as 4,000 µm. Conclusion RPDP rehabilitation improves the ability to reduce the bolus particle size, but does not reestablish fully the masticatory function. Clinical relevance This study encourages the clinical improvement of oral rehabilitation procedure. PMID:24212983

  20. Evaluation of analytical performance based on partial order methodology.

    Science.gov (United States)

    Carlsen, Lars; Bruggemann, Rainer; Kenessova, Olga; Erzhigitov, Erkin

    2015-01-01

    Classical measurements of performances are typically based on linear scales. However, in analytical chemistry a simple scale may be not sufficient to analyze the analytical performance appropriately. Here partial order methodology can be helpful. Within the context described here, partial order analysis can be seen as an ordinal analysis of data matrices, especially to simplify the relative comparisons of objects due to their data profile (the ordered set of values an object have). Hence, partial order methodology offers a unique possibility to evaluate analytical performance. In the present data as, e.g., provided by the laboratories through interlaboratory comparisons or proficiency testings is used as an illustrative example. However, the presented scheme is likewise applicable for comparison of analytical methods or simply as a tool for optimization of an analytical method. The methodology can be applied without presumptions or pretreatment of the analytical data provided in order to evaluate the analytical performance taking into account all indicators simultaneously and thus elucidating a "distance" from the true value. In the present illustrative example it is assumed that the laboratories analyze a given sample several times and subsequently report the mean value, the standard deviation and the skewness, which simultaneously are used for the evaluation of the analytical performance. The analyses lead to information concerning (1) a partial ordering of the laboratories, subsequently, (2) a "distance" to the Reference laboratory and (3) a classification due to the concept of "peculiar points". Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Partial discharge transients: The field theoretical approach

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C

    1998-01-01

    Up until the mid-1980s the theory of partial discharge transients was essentially static. This situation had arisen because of the fixation with the concept of void capacitance and the use of circuit theory to address what is in essence a field problem. Pedersen rejected this approach and instead...... began to apply field theory to the problem of partial discharge transients. In the present paper, the contributions of Pedersen using the field theoretical approach will be reviewed and discussed....

  2. A Model for Partial Kantian Cooperation

    OpenAIRE

    Kordonis, Ioannis

    2016-01-01

    This work presents a game theoretic model to describe game situations in which there is a partial cooperation among the players. Specifically, we assume that the players partially follow Kant's "Categorical Imperative". The model is stated for games with a continuum of players and the basic assumption made is that the participants consider that they belong to virtual groups in which they optimize their actions as if they were bound to follow the same strategy. The relation with the Nash, (Ben...

  3. On the Partiality of Procreative Beneficence

    DEFF Research Database (Denmark)

    Petersen, Thomas Søbirk

    2015-01-01

    The aim of this paper is to criticise the well-discussed principle of Procreative Beneficence (PB) lately refined by Julian Savulescu and Guy Kahane. First, it is argued that advocates of PB leave us with an implausible justification for the moral partiality towards the child (or children) which...... the target. Finally, a genuine counterexample to PB is developed in order to show that the partiality of PB leads to the wrong answer in a specific case....

  4. Pancharatnam geometric phase originating from successive partial ...

    Indian Academy of Sciences (India)

    Pancharatnam connection [1,2] dictates that ψp is in phase ψ0. The partial projection effects a ... up to a real multiplier. Here again, ψf is in phase with ψp but relative to ψ0, has a .... For the third partial projection of strength t3 and an azimuth angle φ13 to effect a triangle closure for both initial states |z〉 and | − z〉, we derive ...

  5. Exp-function method for solving fractional partial differential equations.

    Science.gov (United States)

    Zheng, Bin

    2013-01-01

    We extend the Exp-function method to fractional partial differential equations in the sense of modified Riemann-Liouville derivative based on nonlinear fractional complex transformation. For illustrating the validity of this method, we apply it to the space-time fractional Fokas equation and the nonlinear fractional Sharma-Tasso-Olver (STO) equation. As a result, some new exact solutions for them are successfully established.

  6. Spreading paths in partially observed social networks

    Science.gov (United States)

    Onnela, Jukka-Pekka; Christakis, Nicholas A.

    2012-03-01

    Understanding how and how far information, behaviors, or pathogens spread in social networks is an important problem, having implications for both predicting the size of epidemics, as well as for planning effective interventions. There are, however, two main challenges for inferring spreading paths in real-world networks. One is the practical difficulty of observing a dynamic process on a network, and the other is the typical constraint of only partially observing a network. Using static, structurally realistic social networks as platforms for simulations, we juxtapose three distinct paths: (1) the stochastic path taken by a simulated spreading process from source to target; (2) the topologically shortest path in the fully observed network, and hence the single most likely stochastic path, between the two nodes; and (3) the topologically shortest path in a partially observed network. In a sampled network, how closely does the partially observed shortest path (3) emulate the unobserved spreading path (1)? Although partial observation inflates the length of the shortest path, the stochastic nature of the spreading process also frequently derails the dynamic path from the shortest path. We find that the partially observed shortest path does not necessarily give an inflated estimate of the length of the process path; in fact, partial observation may, counterintuitively, make the path seem shorter than it actually is.

  7. Spreading paths in partially observed social networks.

    Science.gov (United States)

    Onnela, Jukka-Pekka; Christakis, Nicholas A

    2012-03-01

    Understanding how and how far information, behaviors, or pathogens spread in social networks is an important problem, having implications for both predicting the size of epidemics, as well as for planning effective interventions. There are, however, two main challenges for inferring spreading paths in real-world networks. One is the practical difficulty of observing a dynamic process on a network, and the other is the typical constraint of only partially observing a network. Using static, structurally realistic social networks as platforms for simulations, we juxtapose three distinct paths: (1) the stochastic path taken by a simulated spreading process from source to target; (2) the topologically shortest path in the fully observed network, and hence the single most likely stochastic path, between the two nodes; and (3) the topologically shortest path in a partially observed network. In a sampled network, how closely does the partially observed shortest path (3) emulate the unobserved spreading path (1)? Although partial observation inflates the length of the shortest path, the stochastic nature of the spreading process also frequently derails the dynamic path from the shortest path. We find that the partially observed shortest path does not necessarily give an inflated estimate of the length of the process path; in fact, partial observation may, counterintuitively, make the path seem shorter than it actually is.

  8. Partial HELLP Syndrome: maternal and perinatal outcome

    Directory of Open Access Journals (Sweden)

    Joelcio Francisco Abbade

    Full Text Available CONTEXT: HELLP syndrome is a severe complication of pregnancy characterized by hemolysis, elevated liver enzymes and low platelet count. Some pregnant women develop just one or two of the characteristics of this syndrome, which is termed Partial HELLP Syndrome (PHS. OBJECTIVE: The objective of this study was to evaluate the repercussions on maternal and perinatal outcomes among women that developed PHS and to compare these women with those whose gestational hypertension or preeclampsia did not show alterations for HELLP syndrome in laboratory tests. DESIGN: Observational, retrospective and analytical study. SETTING: Maternity Department of Hospital das Clínicas, Faculdade de Medicina de Botucatu, Universidade Estadual Paulista, Botucatu, São Paulo, Brazil. SAMPLE: Pregnant or post-delivery women who had a blood pressure elevation that was first detected after mid-pregnancy, with or without proteinuria, between January 1990 and December 1995. MAIN MEASUREMENTS: Analysis was made of maternal age, race, parity, hypertension classification, gestational age at the PHS diagnosis, alterations in laboratory tests for HELLP syndrome, time elapsed to discharge from hospital, maternal complications, mode of delivery, incidence of preterm birth, intrauterine growth restriction, stillborn and neonatal death. RESULTS: Three hundred and eighteen women were selected; forty-one women (12.9% had PHS and 277 of them (87.1% did not develop any of the alterations of the HELLP syndrome diagnosis. Preeclampsia was a more frequent type of hypertension in the PHS group than in the hypertension group. None of the women with isolated chronic hypertension developed PHS. The rate of cesarean delivery, eclampsia, and preterm delivery was significantly greater in the PHS group than in the hypertension group. CONCLUSION: We observed that aggressive procedures had been adopted for patients with PHS. These resulted in immediate interruption of pregnancy, with elevated cesarean

  9. Prospective study on laser-assisted laparascopic partial nephrectomy

    Science.gov (United States)

    Sroka, Ronald; Hennig, Georg; Zilinberg, Katja; Khoder, Wael Y.

    2012-02-01

    Introduction: Developments in laparoscopic partial nephrectomy (LPN) opened a demand for surgical tools compatible with laparoscopic manipulations to make laser assisted technique safe, feasible and reproducible. Warm ischemia and bleeding during laparoscopic partial nephrectomy place technical constraints on surgeons. Therefore it was the aim to develop a safe and effective laser assisted partial nephrectomy technique without need for ischemia. Patients and methods: A diode laser emitting light at 1318nm in cw mode was coupled into a bare fibre (core diameter 600 μm) thus able to transfer up to 100W to the tissue. After dry lab experience, a total of 10 patients suffering from kidney malformations underwent laparoscopic/retroperitoneoscopic partial nephrectomy. Clinically, postoperative renal function and serum c-reactive protein (CRP) were monitored. Laser induced coagulation depth and effects on resection margins were evaluated. Demographic, clinical and follow-up data are presented. Using a commercial available fibre guidance instrument for lanringeal intervention, the demands on an innovative laser fibre guidance instrument for the laser assisted laparoscopic partial nephrectomy (LLPN) are summarized. Results: Overall, all laparascopic intervention were succesfull and could be performed without conversion to open surgery. Mean operative time and mean blood loss were comparable to conventional open and laparascopic approaches. Laser assisted resection of the kidney tissue took max 15min. After extirpation of the tumours all patients showed clinical favourable outcome during follow up period. Tumour sizes were measured to be up 5cm in diameter. The depth of the coagulation on the removed tissue ranged between laser assisted coagulated after removal. The sealing of the surface was induced by a slightly larger coagulation margin, but could not measured so far. Based on this experiences a simple and easy to use instrument described serving also for suction and

  10. Compatriot partiality and cosmopolitan justice: Can we justify compatriot partiality within the cosmopolitan framework?

    Directory of Open Access Journals (Sweden)

    Rachelle Bascara

    2016-10-01

    Full Text Available This paper shows an alternative way in which compatriot partiality could be justified within the framework of global distributive justice. Philosophers who argue that compatriot partiality is similar to racial partiality capture something correct about compatriot partiality. However, the analogy should not lead us to comprehensively reject compatriot partiality. We can justify compatriot partiality on the same grounds that liberation movements and affirmative action have been justified. Hence, given cosmopolitan demands of justice, special consideration for the economic well-being of your nation as a whole is justified if and only if the country it identifies is an oppressed developing nation in an unjust global order.This justification is incomplete. We also need to say why Person A, qua national of Country A, is justified in helping her compatriots in Country A over similarly or slightly more oppressed non-compatriots in Country B. I argue that Person A’s partiality towards her compatriots admits further vindication because it is part of an oppressed group’s project of self-emancipation, which is preferable to paternalistic emancipation.Finally, I identify three benefits in my justification for compatriot partiality. First, I do not offer a blanket justification for all forms of compatriot partiality. Partiality between members of oppressed groups is only a temporary effective measure designed to level an unlevel playing field. Second, because history attests that sovereign republics could arise as a collective response to colonial oppression, justifying compatriot partiality on the grounds that I have identified is conducive to the development of sovereignty and even democracy in poor countries, thereby avoiding problems of infringement that many humanitarian poverty alleviation efforts encounter. Finally, my justification for compatriot partiality complies with the implicit cosmopolitan commitment to the realizability of global justice

  11. Comparative thermometric coagulation studies of plasmas from normal outbred Swiss Webster mice and persons.

    Science.gov (United States)

    Tsang, V C; Wyatt, C R; Damian, R T

    1979-06-01

    The functional capabilities of a thermometric clot-timer have been demonstrated in a comparative study of human and mouse plasma coagulation. The influence of some variables on coagulation times of mouse and human plasmas were examined in activated partial thromboplastin time, one-stage prothrombin time, and Russell's viper venom time assays. Mouse plasma coagulation times were generally shorter and more reproducible than those of human plasma. Optimal assay conditions are also described.

  12. Hidden physics models: Machine learning of nonlinear partial differential equations

    Science.gov (United States)

    Raissi, Maziar; Karniadakis, George Em

    2018-03-01

    While there is currently a lot of enthusiasm about "big data", useful data is usually "small" and expensive to acquire. In this paper, we present a new paradigm of learning partial differential equations from small data. In particular, we introduce hidden physics models, which are essentially data-efficient learning machines capable of leveraging the underlying laws of physics, expressed by time dependent and nonlinear partial differential equations, to extract patterns from high-dimensional data generated from experiments. The proposed methodology may be applied to the problem of learning, system identification, or data-driven discovery of partial differential equations. Our framework relies on Gaussian processes, a powerful tool for probabilistic inference over functions, that enables us to strike a balance between model complexity and data fitting. The effectiveness of the proposed approach is demonstrated through a variety of canonical problems, spanning a number of scientific domains, including the Navier-Stokes, Schrödinger, Kuramoto-Sivashinsky, and time dependent linear fractional equations. The methodology provides a promising new direction for harnessing the long-standing developments of classical methods in applied mathematics and mathematical physics to design learning machines with the ability to operate in complex domains without requiring large quantities of data.

  13. Effect of complete and partial removable dentures on chewing movements.

    Science.gov (United States)

    Gonçalves, T M S V; Vilanova, L S R; Gonçalves, L M; Rodrigues Garcia, R C M

    2014-03-01

    Partial or complete edentulism impairs mastication. However, it is unclear how the chewing cycle is affected by prosthetics. We evaluated the chewing movements of patients fitted with complete (CD) or removable partial denture (RPD). A total of 29 subjects were kinesiographically evaluated during chewing of peanuts and Optocal portions in a random sequence. The subjects were divided into two groups according to prosthesis type. Group RPD was composed of 14 partially edentulous patients using a lower distal extension RPD (mean age 61 ± 8 years), and group CD contained 15 completely edentulous patients using CD (mean age 65·9 ± 7·9 years) in both jaws. Opening, closing, occlusal and masticatory cycle times, movement angle (opening and closing), maximum velocity (opening and closing), total area and chewing cycle amplitudes were evaluated. The results were subjected to anova and Tukey's HSD test at a significance level of 5%. The RPD group exhibited shorter opening and closing phases and masticatory cycle time (P chewing envelope was smaller in the CD group (P chewing cycles in any of the parameters evaluated (P > 0·05). RPD wearers use a faster chewing sequence with greater vertical and lateral jaw excursions compared with CD wearers. © 2013 John Wiley & Sons Ltd.

  14. Robotic-assisted partial Nephrectomy: initial experience in South America

    Directory of Open Access Journals (Sweden)

    Gustavo C. Lemos

    2011-08-01

    Full Text Available OBJECTIVE:To report the initial outcomes of robotic-assisted partial nephrectomy in a tertiary center in South America. MATERIAL AND METHODS: From 11/2008 to 12/2009, a total of 16 transperitoneal robotic-assisted partial nephrectomies were performed in 15 patients to treat 18 kidney tumors. One patient with bilateral tumor had two procedures, while two patients with two synchronous unilateral tumors had a single operation to remove them. Eleven (73% patients were male and the right kidney was affected in 7 (46% patients. The median patient age and tumor size were 57 years old and 30 mm, respectively. Five (28% tumors were hilar and/or centrally located. RESULTS: The median operative time, warm ischemia time and estimated blood loss was 140 min, 27 min and 120 mL, respectively. Blood transfusion was required in one patient with bilateral tumor, and one additional pyelolithotomy was performed due to a 15mm stone located in the renal pelvis. The histopathology analysis showed 15 (83% malignant tumors, which 10 (67% were clear cell carcinoma. The median hospital stay was 72 hrs and no major complication was observed. CONCLUSION: Robotic-assisted partial nephrectomy is safe and represents a valuable option to perform minimally invasive nephron-sparing surgery.

  15. Associations between partial sickness benefit and disability pensions: initial findings of a Finnish nationwide register study.

    Science.gov (United States)

    Kausto, Johanna; Virta, Lauri; Luukkonen, Ritva; Viikari-Juntura, Eira

    2010-06-23

    Timely return to work after longterm sickness absence and the increased use of flexible work arrangements together with partial health-related benefits are tools intended to increase participation in work life. Although partial sickness benefit and partial disability pension are used in many countries, prospective studies on their use are largely lacking. Partial sickness benefit was introduced in Finland in 2007. This register study aimed to investigate the use of health-related benefits by subjects with prolonged sickness absence, initially on either partial or full sick leave. Representative population data (13 375 men and 16 052 women either on partial or full sick leave in 2007) were drawn from national registers and followed over an average of 18 months. The registers provided information on the study outcomes: diagnoses and days of payment for compensated sick leaves, and the occurrence of disability pension. Survival analysis and multinomial regression were carried out using sociodemographic variables and prior sickness absence as covariates. Approximately 60% of subjects on partial sick leave and 30% of those on full sick leave had at least one recurrent sick leave over the follow up. A larger proportion of those on partial sick leave (16%) compared to those on full sick leave (1%) had their first recurrent sick leave during the first month of follow up. The adjusted risks of the first recurrent sick leave were 1.8 and 1.7 for men and women, respectively, when subjects on partial sick leave were compared with those on full sick leave. There was no increased risk when those with their first recurrent sick leave in the first month were excluded from the analyses. The risks of a full disability pension were smaller and risks of a partial disability pension approximately two-fold among men and women initially on partial sick leave, compared to subjects on full sick leave. This is the first follow up study of the newly adopted partial sickness benefit in

  16. Associations between partial sickness benefit and disability pensions: initial findings of a Finnish nationwide register study

    Directory of Open Access Journals (Sweden)

    Luukkonen Ritva

    2010-06-01

    Full Text Available Abstract Background Timely return to work after longterm sickness absence and the increased use of flexible work arrangements together with partial health-related benefits are tools intended to increase participation in work life. Although partial sickness benefit and partial disability pension are used in many countries, prospective studies on their use are largely lacking. Partial sickness benefit was introduced in Finland in 2007. This register study aimed to investigate the use of health-related benefits by subjects with prolonged sickness absence, initially on either partial or full sick leave. Methods Representative population data (13 375 men and 16 052 women either on partial or full sick leave in 2007 were drawn from national registers and followed over an average of 18 months. The registers provided information on the study outcomes: diagnoses and days of payment for compensated sick leaves, and the occurrence of disability pension. Survival analysis and multinomial regression were carried out using sociodemographic variables and prior sickness absence as covariates. Results Approximately 60% of subjects on partial sick leave and 30% of those on full sick leave had at least one recurrent sick leave over the follow up. A larger proportion of those on partial sick leave (16% compared to those on full sick leave (1% had their first recurrent sick leave during the first month of follow up. The adjusted risks of the first recurrent sick leave were 1.8 and 1.7 for men and women, respectively, when subjects on partial sick leave were compared with those on full sick leave. There was no increased risk when those with their first recurrent sick leave in the first month were excluded from the analyses. The risks of a full disability pension were smaller and risks of a partial disability pension approximately two-fold among men and women initially on partial sick leave, compared to subjects on full sick leave. Conclusions This is the first follow

  17. Nicotine receptor partial agonists for smoking cessation

    Directory of Open Access Journals (Sweden)

    Kate Cahill

    Full Text Available BACKGROUND: Nicotine receptor partial agonists may help people to stop smoking by a combination of maintaining moderate levels of dopamine to counteract withdrawal symptoms (acting as an agonist and reducing smoking satisfaction (acting as an antagonist. OBJECTIVES: The primary objective of this review is to assess the efficacy and tolerability of nicotine receptor partial agonists, including cytisine, dianicline and varenicline for smoking cessation. SEARCH METHODS: We searched the Cochrane Tobacco Addiction Group's specialised register for trials, using the terms ('cytisine' or 'Tabex' or 'dianicline' or 'varenicline' or 'nicotine receptor partial agonist' in the title or abstract, or as keywords. The register is compiled from searches of MEDLINE, EMBASE, PsycINFO and Web of Science using MeSH terms and free text to identify controlled trials of interventions for smoking cessation and prevention. We contacted authors of trial reports for additional information where necessary. The latest update of the specialized register was in December 2011. We also searched online clinical trials registers. SELECTION CRITERIA: We included randomized controlled trials which compared the treatment drug with placebo. We also included comparisons with bupropion and nicotine patches where available. We excluded trials which did not report a minimum follow-up period of six months from start of treatment. DATA COLLECTION AND ANALYSIS: We extracted data on the type of participants, the dose and duration of treatment, the outcome measures, the randomization procedure, concealment of allocation, and completeness of follow-up. The main outcome measured was abstinence from smoking at longest follow-up. We used the most rigorous definition of abstinence, and preferred biochemically validated rates where they were reported. Where appropriate we pooled risk ratios (RRs, using the Mantel-Haenszel fixed-effect model. MAIN RESULTS: Two recent cytisine trials (937 people

  18. Nicotine receptor partial agonists for smoking cessation.

    Science.gov (United States)

    Cahill, Kate; Stead, Lindsay F; Lancaster, Tim

    2012-04-18

    Nicotine receptor partial agonists may help people to stop smoking by a combination of maintaining moderate levels of dopamine to counteract withdrawal symptoms (acting as an agonist) and reducing smoking satisfaction (acting as an antagonist). The primary objective of this review is to assess the efficacy and tolerability of nicotine receptor partial agonists, including cytisine, dianicline and varenicline for smoking cessation. We searched the Cochrane Tobacco Addiction Group's specialised register for trials, using the terms ('cytisine' or 'Tabex' or 'dianicline' or 'varenicline' or 'nicotine receptor partial agonist') in the title or abstract, or as keywords. The register is compiled from searches of MEDLINE, EMBASE, PsycINFO and Web of Science using MeSH terms and free text to identify controlled trials of interventions for smoking cessation and prevention. We contacted authors of trial reports for additional information where necessary. The latest update of the specialised register was in December 2011. We also searched online clinical trials registers. We included randomized controlled trials which compared the treatment drug with placebo. We also included comparisons with bupropion and nicotine patches where available. We excluded trials which did not report a minimum follow-up period of six months from start of treatment. We extracted data on the type of participants, the dose and duration of treatment, the outcome measures, the randomization procedure, concealment of allocation, and completeness of follow-up.The main outcome measured was abstinence from smoking at longest follow-up. We used the most rigorous definition of abstinence, and preferred biochemically validated rates where they were reported. Where appropriate we pooled risk ratios (RRs), using the Mantel-Haenszel fixed-effect model. Two recent cytisine trials (937 people) found that more participants taking cytisine stopped smoking compared with placebo at longest follow-up, with a pooled RR of

  19. CIME course on Control of Partial Differential Equations

    CERN Document Server

    Alabau-Boussouira, Fatiha; Glass, Olivier; Le Rousseau, Jérôme; Zuazua, Enrique

    2012-01-01

    The term “control theory” refers to the body of results - theoretical, numerical and algorithmic - which have been developed to influence the evolution of the state of a given system in order to meet a prescribed performance criterion. Systems of interest to control theory may be of very different natures. This monograph is concerned with models that can be described by partial differential equations of evolution. It contains five major contributions and is connected to the CIME Course on Control of Partial Differential Equations that took place in Cetraro (CS, Italy), July 19 - 23, 2010.  Specifically, it covers the stabilization of evolution equations, control of the Liouville equation, control in fluid mechanics, control and numerics for the wave equation, and Carleman estimates for elliptic and parabolic equations with application to control. We are confident this work will provide an authoritative reference work for all scientists who are interested in this field, representing at the same time a fri...

  20. Partial removal and post-operative irradiation for craniopharyngioma

    International Nuclear Information System (INIS)

    Nishioka, Takeshi; Shirato, Hiroki; Arimoto, Takuro; Kamata, Tadashi; Suzuki, Keishiro; Kitahara, Toshihiro.

    1992-01-01

    From 1971 to 1990, sixteen patients with craniopharyngioma were treated by postoperative radiotherapy (RT). Fourteen patients underwent partial removal and RT as primary treatment. In two patients, partial removal and RT were performed for treatment of recurrence after total removal. Total dose was between 40 Gy and 60 Gy. Five year survival and 5-year relapse free rates after RT were 100% and 71.7%, respectively. Computed tomography raised suspicion of radiation necrosis in two patients, each treated with two opposing lateral ports. The following hormonal replacements were needed: adrenal in 73% of the patients, thyroid in 66%, growth hormone in 50% of the children, and antidiuretic hormone in 21%. The amounts of thyroid and adrenal hormones for substitution have increased gradually with elapsed time after RT. To minimize these complications and to achieve tumor control, a multiport technique including radiosurgery, and a total dose of 50-55 Gy with 2 Gy per fraction is suggested to be optimal. (author)

  1. Partial Safety Factors for Fatigue Design of Wind Turbine Blades

    DEFF Research Database (Denmark)

    Toft, Henrik Stensgaard; Sørensen, John Dalsgaard

    2010-01-01

    In the present paper calibration of partial safety factors for fatigue design of wind turbine blades is considered. The stochastic models for the physical uncertainties on the material properties are based on constant amplitude fatigue tests and the uncertainty on Miners rule for linear damage...... accumulation is determined from variable amplitude fatigue tests with the Wisper and Wisperx spectra. The statistical uncertainty for the assessment of the fatigue loads is also investigated. The partial safety factors are calibrated for design load case 1.2 in IEC 61400-1. The fatigue loads are determined...... from rainflow-counting of simulated time series for a 5MW reference wind turbine [1]. A possible influence of a complex stress state in the blade is not taken into account and only longitudinal stresses are considered....

  2. Partial removal and post-operative irradiation for craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Nishioka, Takeshi; Shirato, Hiroki (Obihiro Kousei Hospital, Hokkaido (Japan)); Arimoto, Takuro; Kamata, Tadashi; Suzuki, Keishiro; Kitahara, Toshihiro

    1992-12-01

    From 1971 to 1990, sixteen patients with craniopharyngioma were treated by postoperative radiotherapy (RT). Fourteen patients underwent partial removal and RT as primary treatment. In two patients, partial removal and RT were performed for treatment of recurrence after total removal. Total dose was between 40 Gy and 60 Gy. Five year survival and 5-year relapse free rates after RT were 100% and 71.7%, respectively. Computed tomography raised suspicion of radiation necrosis in two patients, each treated with two opposing lateral ports. The following hormonal replacements were needed: adrenal in 73% of the patients, thyroid in 66%, growth hormone in 50% of the children, and antidiuretic hormone in 21%. The amounts of thyroid and adrenal hormones for substitution have increased gradually with elapsed time after RT. To minimize these complications and to achieve tumor control, a multiport technique including radiosurgery, and a total dose of 50-55 Gy with 2 Gy per fraction is suggested to be optimal. (author).

  3. Ultrasound-assisted endoscopic partial plantar fascia release.

    Science.gov (United States)

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.

  4. Clinical Application of Scaffolds for Partial Meniscus Replacement.

    Science.gov (United States)

    Moran, Cathal J; Withers, Daniel P; Kurzweil, Peter R; Verdonk, Peter C

    2015-09-01

    Meniscal tears are common injuries often treated by partial meniscectomy. This may result in altered joint contact mechanics which in turn may lead to worsening symptoms and an increased risk of osteoarthritis. Meniscal scaffolds have been proposed as a treatment option aimed at reducing symptoms while also potentially reducing progression of degenerative change. There are 2 scaffolds available for clinical use at the present time; Collagen Meniscus Implant and Actifit. Medium-term to long-term data (4.9 to 11.3 y) demonstrate efficacy of partial meniscus replacement. The patients who seem to benefit most are chronic postmeniscectomy rather than acute meniscal injuries. Herein we report on available clinical data for Collagen Meniscus Implant and Actifit while describing our preferred surgical technique and postoperative rehabilitation program.

  5. A novel technique for partial discharge measurement

    International Nuclear Information System (INIS)

    Farrokh, Fattahi; Navid, Tagizadegan; Ahmad, Zentabchi; Mehdi, Rashidi

    2005-01-01

    Full text : Partial discharges are a sensitive measure of local electrical stress and therefore the measurements is very often used as a quality check of the insulation. The inception of partial discharges gives information on the limit of the electrical strength of the insulating material before a complete discharge between the conductors takes place. Therefore the insulating material can be tested with high stress but without damaging or reducing the performance of the insulation. Also, for partial discharge measurements it should be taken into account that every stress of the insulation will have an influence on the life expectancy of the material, but a reasonable compromise between the stress during the measurement in order to get reliable results and the influence of he lifetime should be found and established in the relevant standard for the particular equipment, for example transformers, cables and so on

  6. Thin film oxygen partial pressure sensor

    Science.gov (United States)

    Wortman, J. J.; Harrison, J. W.; Honbarrier, H. L.; Yen, J.

    1972-01-01

    The development is described of a laboratory model oxygen partial pressure sensor using a sputtered zinc oxide thin film. The film is operated at about 400 C through the use of a miniature silicon bar. Because of the unique resistance versus temperature relation of the silicon bar, control of the operational temperature is achieved by controlling the resistance. A circuit for accomplishing this is described. The response of sputtered zinc oxide films of various thicknesses to oxygen, nitrogen, argon, carbon dioxide, and water vapor caused a change in the film resistance. Over a large range, film conductance varied approximately as the square root of the oxygen partial pressure. The presence of water vapor in the gas stream caused a shift in the film conductance at a given oxygen partial pressure. A theoretical model is presented to explain the characteristic features of the zinc oxide response to oxygen.

  7. Particle Systems and Partial Differential Equations I

    CERN Document Server

    Gonçalves, Patricia

    2014-01-01

    This book presents the proceedings of the international conference Particle Systems and Partial Differential Equations I, which took place at the Centre of Mathematics of the University of Minho, Braga, Portugal, from the 5th to the 7th of December, 2012.  The purpose of the conference was to bring together world leaders to discuss their topics of expertise and to present some of their latest research developments in those fields. Among the participants were researchers in probability, partial differential equations and kinetics theory. The aim of the meeting was to present to a varied public the subject of interacting particle systems, its motivation from the viewpoint of physics and its relation with partial differential equations or kinetics theory, and to stimulate discussions and possibly new collaborations among researchers with different backgrounds.  The book contains lecture notes written by François Golse on the derivation of hydrodynamic equations (compressible and incompressible Euler and Navie...

  8. Partial Thickness Rotator Cuff Tears: Current Concepts

    Science.gov (United States)

    Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.

    2015-01-01

    Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251

  9. Partially massless graviton on beyond Einstein spacetimes

    Science.gov (United States)

    Bernard, Laura; Deffayet, Cédric; Hinterbichler, Kurt; von Strauss, Mikael

    2017-06-01

    We show that a partially massless graviton can propagate on a large set of spacetimes which are not Einstein spacetimes. Starting from a recently constructed theory for a massive graviton that propagates the correct number of degrees of freedom on an arbitrary spacetime, we first give the full explicit form of the scalar constraint responsible for the absence of a sixth degree of freedom. We then spell out generic conditions for the constraint to be identically satisfied, so that there is a scalar gauge symmetry which makes the graviton partially massless. These simplify if one assumes that spacetime is Ricci symmetric. Under this assumption, we find explicit non-Einstein spacetimes (some, but not all, with vanishing Bach tensors) allowing for the propagation of a partially massless graviton. These include in particular the Einstein static Universe.

  10. Partial Thickness Rotator Cuff Tears: Current Concepts

    Directory of Open Access Journals (Sweden)

    Graeme Matthewson

    2015-01-01

    Full Text Available Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized.

  11. Partial Cavity Flows at High Reynolds Numbers

    Science.gov (United States)

    Makiharju, Simo; Elbing, Brian; Wiggins, Andrew; Dowling, David; Perlin, Marc; Ceccio, Steven

    2009-11-01

    Partial cavity flows created for friction drag reduction were examined on a large-scale. Partial cavities were investigated at Reynolds numbers up to 120 million, and stable cavities with frictional drag reduction of more than 95% were attained at optimal conditions. The model used was a 3 m wide and 12 m long flat plate with a plenum on the bottom. To create the partial cavity, air was injected at the base of an 18 cm backwards-facing step 2.1 m from the leading edge. The geometry at the cavity closure was varied for different flow speeds to optimize the closure of the cavity. Cavity gas flux, thickness, frictional loads, and cavity pressures were measured over a range of flow speeds and air injection fluxes. High-speed video was used extensively to investigate the unsteady three dimensional cavity closure, the overall cavity shape and oscillations.

  12. Robotic partial nephrectomy for complex renal tumors: surgical technique.

    Science.gov (United States)

    Rogers, Craig G; Singh, Amar; Blatt, Adam M; Linehan, W Marston; Pinto, Peter A

    2008-03-01

    Laparoscopic partial nephrectomy requires advanced training to accomplish tumor resection and renal reconstruction while minimizing warm ischemia times. Complex renal tumors add an additional challenge to a minimally invasive approach to nephron-sparing surgery. We describe our technique, illustrated with video, of robotic partial nephrectomy for complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance was used to resect 14 tumors in eight patients (mean age: 50.3 yr; range: 30-68 yr). Three patients had hereditary kidney cancer. All patients had complex tumor features, including hilar tumors (n=5), endophytic tumors (n=4), and/or multiple tumors (n=3). Robotic partial nephrectomy procedures were performed successfully without complications. Hilar clamping was used with a mean warm ischemia time of 31 min (range: 24-45 min). Mean blood loss was 230 ml (range: 100-450 ml). Histopathology confirmed clear-cell renal cell carcinoma (n=3), hybrid oncocytic tumor (n=2), chromophobe renal cell carcinoma (n=2), and oncocytoma (n=1). All patients had negative surgical margins. Mean index tumor size was 3.6 cm (range: 2.6-6.4 cm). Mean hospital stay was 2.6 d. At 3-mo follow-up, no patients experienced a statistically significant change in serum creatinine or estimated glomerular filtration rate and there was no evidence of tumor recurrence. Robotic partial nephrectomy is safe and feasible for select patients with complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance may facilitate a minimally invasive, nephron-sparing approach for select patients with complex renal tumors who might otherwise require open surgery or total nephrectomy.

  13. Partial discharges in ellipsoidal and spheroidal voids

    DEFF Research Database (Denmark)

    Crichton, George C; Karlsson, P. W.; Pedersen, Aage

    1989-01-01

    Transients associated with partial discharges in voids can be described in terms of the charges induced on the terminal electrodes of the system. The relationship between the induced charge and the properties which are usually measured is discussed. The method is illustrated by applying it to a s......Transients associated with partial discharges in voids can be described in terms of the charges induced on the terminal electrodes of the system. The relationship between the induced charge and the properties which are usually measured is discussed. The method is illustrated by applying...

  14. arXiv Minimal Fundamental Partial Compositeness

    CERN Document Server

    Cacciapaglia, Giacomo; Sannino, Francesco; Thomsen, Anders Eller

    Building upon the fundamental partial compositeness framework we provide consistent and complete composite extensions of the standard model. These are used to determine the effective operators emerging at the electroweak scale in terms of the standard model fields upon consistently integrating out the heavy composite dynamics. We exhibit the first effective field theories matching these complete composite theories of flavour and analyse their physical consequences for the third generation quarks. Relations with other approaches, ranging from effective analyses for partial compositeness to extra dimensions as well as purely fermionic extensions, are briefly discussed. Our methodology is applicable to any composite theory of dynamical electroweak symmetry breaking featuring a complete theory of flavour.

  15. Higher-Order Rewriting and Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier; Rose, Kristoffer H.

    1997-01-01

    transformations as meta-reductions, i.e., reductions in the internal “substitution calculus.” For partial-evaluation problems, this means that instead of having to prove on a case-by-case basis that one's “two-level functions” operate properly, one can concisely formalize them as a combinatory reduction system...... and obtain as a corollary that static reduction does not go wrong and yields a well-formed residual program. We have found that the CRS substitution calculus provides an adequate expressive power to formalize partial evaluation: it provides sufficient termination strength while avoiding the need...

  16. Flexible removable partial dentures: a basic overview.

    Science.gov (United States)

    Hill, Edward E; Rubel, Barry; Smith, John B

    2014-01-01

    For many years, flexible resin materials have been available for fabricating removable partial denture (RPD) prostheses. Using a nonrigid material for the major connector or other components of an RPD may be a consideration for certain patients. Except for the promotional literature that has been written for flexible resin dentures, there is very little information available in the dental literature concerning nonrigid RPDs. As a result, the decision to use this treatment option depends on the judgment and experience of the dentist and fabricating laboratory. This article summarizes clinically pertinent information about flexible, nonrigid partial dentures.

  17. DEVICE FOR CONTROL OF OXYGEN PARTIAL PRESSURE

    Science.gov (United States)

    Bradner, H.; Gordon, H.S.

    1957-12-24

    A device is described that can sense changes in oxygen partial pressure and cause a corresponding mechanical displacement sufficient to actuate meters, valves and similar devices. A piston and cylinder arrangement contains a charge of crystalline metal chelate pellets which have the peculiar property of responding to variations in the oxygen content of the ambient atmosphere by undergoing a change in dimension. A lever system amplifies the relative displacement of the piston in the cylinder, and actuates the controlled valving device. This partial pressure oxygen sensing device is useful in controlled chemical reactions or in respiratory devices such as the oxygen demand meters for high altitude aircraft.

  18. Partial gravity - Human impacts on facility design

    Science.gov (United States)

    Capps, Stephen; Moore, Nathan

    1990-01-01

    Partial gravity affects the body differently than earth gravity and microgravity environments. The main difference from earth gravity is human locomotion; while the main dfference from microgravity is the specific updown orientation and reach envelopes which increase volume requirements. Much data are available on earth gravity and microgravity design; however, very little information is available on human reactions to reduced gravity levels in IVA situations (without pressure suits). Therefore, if humans commit to permanent lunar habitation, much research should be conducted in the area of partial gravity effects on habitat design.

  19. Proximal Hamstring Tendinosis and Partial Ruptures.

    Science.gov (United States)

    Startzman, Ashley N; Fowler, Oliver; Carreira, Dominic

    2017-07-01

    Proximal hamstring tendinosis and partial hamstring origin ruptures are painful conditions of the proximal thigh and hip that may occur in the acute, chronic, or acute on chronic setting. Few publications exist related to their diagnosis and management. This systematic review discusses the incidence, treatment, and prognosis of proximal hamstring tendinosis and partial hamstring ruptures. Conservative treatment measures include nonsteroidal anti-inflammatory drugs, physical therapy, rest, and ice. If these measures fail, platelet-rich plasma or shockwave therapy may be considered. When refractory to conservative management, these injuries may be treated with surgical debridement and hamstring reattachment. [Orthopedics. 2017; 40(4):e574-e582.]. Copyright 2017, SLACK Incorporated.

  20. Partial oxidation of 2-propanol on perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Sumathi, R.; Viswanathan, B.; Varadarajan, T.K. [Indian Inst. of Tech., Madras (India). Dept. of Chemistry

    1998-12-31

    Partial oxidation of 2-propanol was carried out on AB{sub 1-x}B`{sub x}O{sub 3} (A=Ba, B=Pb, Ce, Ti; B`=Bi, Sb and Cu) type perovskite oxides. Acetone was the major product observed on all the catalysts. All the catalysts underwent partial reduction during the reaction depending on the composition of the reactant, nature of the B site cation and the extent of substitution at B site. The catalytic activity has been correlated with the reducibility of the perovskite oxides determined from Temperature Programmed Reduction (TPR) studies. (orig.)

  1. Generalized solutions of nonlinear partial differential equations

    CERN Document Server

    Rosinger, EE

    1987-01-01

    During the last few years, several fairly systematic nonlinear theories of generalized solutions of rather arbitrary nonlinear partial differential equations have emerged. The aim of this volume is to offer the reader a sufficiently detailed introduction to two of these recent nonlinear theories which have so far contributed most to the study of generalized solutions of nonlinear partial differential equations, bringing the reader to the level of ongoing research.The essence of the two nonlinear theories presented in this volume is the observation that much of the mathematics concernin

  2. The efficacy of incorporating partial squats in maximal strength training.

    Science.gov (United States)

    Bazyler, Caleb D; Sato, Kimitake; Wassinger, Craig A; Lamont, Hugh S; Stone, Michael H

    2014-11-01

    The purpose of our study was to examine the effects of 2 different training methods on dynamic and isometric measures of maximal strength. Seventeen recreationally trained men (1 repetition maximum [1RM] squat: 146.9 ± 22.4 kg) were assigned to 2 groups: full range of motion (ROM) squat (F) and full ROM with partial ROM squat (FP) for the 7-week training intervention. Repeated measures analysis of variance revealed that there was a statistically significant group-by-time interaction for impulse scaled at 50, 90, and 250 milliseconds at 90° of knee flexion and rate of force development at 200 milliseconds with 120° of knee flexion (p ≤ 0.05). There was also a statistically significant time effect (p ≤ 0.05) for the 1RM squat, 1RM partial squat, isometric squat peak force allometrically scaled (IPFa) 90°, IPFa 120°, and impulse allometrically scaled at 50, 90, 200, and 250 milliseconds at 90° and 120° of knee flexion. Additionally, the FP group achieved statistically larger relative training intensities (%1RM) during the final 3 weeks of training (p ≤ 0.05). There was a trend for FP to improve over F in 1RM squat (+3.1%, d = 0.53 vs. 0.32), 1RM partial squat (+4.7%, d = 0.95 vs. 0.69), IPFa 120° (+5.7%, d = 0.52 vs. 0.12), and impulse scaled at 50, 90, 200, and 250 milliseconds at 90° (+6.3 to 13.2%, d = 0.50-1.01 vs. 0.30-0.57) and 120° (+3.4 to 16.8%, d = 0.45-1.11 vs. 0.08-0.37). These larger effect sizes in the FP group can likely be explained their ability to train at larger relative training intensities during the final 3 weeks of training resulting in superior training adaptations. Our findings suggest that partial ROM squats in conjunction with full ROM squats may be an effective training method for improving maximal strength and early force-time curve characteristics in men with previous strength training experience. Practically, partial squats may be beneficial for strength and power athletes during a strength-speed mesocycle while peaking

  3. Barrelet zeros in partial wave analysis

    International Nuclear Information System (INIS)

    Baker, R.D.

    1976-01-01

    The formalism of Barrelet zeros is discussed. Spinless scattering is described to introduce the idea, then the more usual case of 0 - 1/2 + → 0 - 1/2 + scattering. The zeros are regarded here only as a means to an end, viz the partial waves. The extraction of these is given in detail, and ambiguities are discussed at length. (author)

  4. Partial discharges in spheroidal voids: Void orientation

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson

    1997-01-01

    Partial discharge transients can be described in terms of the charge induced on the detecting electrode. The influence of the void parameters upon the induced charge is examined and discussed for spheroidal voids. It is shown that a quantitative interpretation of the induced charge requires...

  5. Partial splenectomy in children with Gaucher's disease

    International Nuclear Information System (INIS)

    Bar-Maor, J.A.; Govrin-Yehudain, J.

    1985-01-01

    Because of hypersplenism and mechanical problems, partial splenectomy was performed in four children with Gaucher's disease. Subsequently, one of the patients underwent a total splenectomy due to bleeding from the remnant of the spleen. At the follow-up of the other three patients, an isotope scan showed that the remaining spleen was functioning well

  6. Partial Hospitalization Programs: A Current Perspective.

    Science.gov (United States)

    Whitelaw, Carolyn A.; Perez, Edgardo L.

    1987-01-01

    Reviews the historical background, standards, the issue of day treatment versus day care, functional issues, specialization, efficacy and cost effectiveness, utilization issues, and alternative models of care of partial hospitalization programs in North America. Emphasizes issues of relevance when planning alternative programs to inpatient…

  7. Partial chord diagrams and matrix models

    DEFF Research Database (Denmark)

    Andersen, Jørgen Ellegaard; Fuji, Hiroyuki; Manabe, Masahide

    In this article, the enumeration of partial chord diagrams is discussed via matrix model techniques. In addition to the basic data such as the number of backbones and chords, we also consider the Euler characteristic, the backbone spectrum, the boundary point spectrum, and the boundary length spe...

  8. [Elderly people and removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de

    2009-01-01

    The most frequently reported disadvantages of removable partial dentures are the more demanding daily oral hygiene self-care, especially for people who already experience difficulties in self-care, and the possible harmful influence on the remaining dentition. These disadvantages can be expressed in

  9. Dual Component Removable Partial Denture shows improved ...

    African Journals Online (AJOL)

    Dual Component Removable Partial Denture (DuCo RPD) is composed of a double base; lower and upper. The lower base, where the artificial teeth are attached, acts as a support and is in contact with the alveolar ridges and oral mucosa. Clasps are designed on the upper base, which acts towards the retention and ...

  10. [Resin-bonded fixed partial dentures

    NARCIS (Netherlands)

    Kreulen, C.M.; Creugers, N.H.J.

    2013-01-01

    A resin-bonded fixed partial denture is a prosthetic construction which can replace I or several teeth in an occlusal system and which comprises a pontic element which is adhesively attached to 1 or more abutment teeth. To compensate for the limited shear strength of the adhesive layer, the Jixed

  11. Permissive Subsorted Partial Logic in CASL

    DEFF Research Database (Denmark)

    Cerioli, Maura; Haxthausen, Anne Elisabeth; Krieg-Brückner, Bernd

    1997-01-01

    This paper presents a permissive subsorted partial logic used in the CoFI Algebraic Specification Language. In contrast to other order-sorted logics, subsorting is not modeled by set inclusions, but by injective embeddings allowing for more general models in which subtypes can have different data...

  12. Canonical coordinates for partial differential equations

    Science.gov (United States)

    Hunt, L. R.; Villarreal, Ramiro

    1988-01-01

    Necessary and sufficient conditions are found under which operators of the form Sigma (m, j=1) x (2) sub j + X sub O can be made constant coefficient. In addition, necessary and sufficient conditions are derived which classify those linear partial differential operators that can be moved to the Kolmogorov type.

  13. Canonical coordinates for partial differential equations

    Science.gov (United States)

    Hunt, L. R.; Villarreal, Ramiro

    1987-01-01

    Necessary and sufficient conditions are found under which operators of the form Sigma(m, j=1) X(2)sub j + X sub 0 can be made constant coefficient. In addition, necessary and sufficient conditions are derived which classify those linear partial differential operators that can be moved to the Kolmogorov type.

  14. Monitoring as a partially observable decision problem

    Science.gov (United States)

    Paul L. Fackler; Robert G. Haight

    2014-01-01

    Monitoring is an important and costly activity in resource man-agement problems such as containing invasive species, protectingendangered species, preventing soil erosion, and regulating con-tracts for environmental services. Recent studies have viewedoptimal monitoring as a Partially Observable Markov Decision Pro-cess (POMDP), which provides a framework for...

  15. Atomic disintegrations for partially hyperbolic diffeomorphisms

    NARCIS (Netherlands)

    Homburg, Ale Jan

    2017-01-01

    Shub and Wilkinson and Ruelle and Wilkinson studied a class of volume preserving diffeomorphisms on the three dimensional torus that are stably ergodic. The diffeomorphisms are partially hyperbolic and admit an invariant central foliation of circles. The foliation is not absolutely continuous; in

  16. First symposium accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    2012-01-01

    The First symposium accelerated partial breast irradiation, was organized by the Marie Curie Foundation, between the 14 to 16 june 2012, in the Cordoba city of Argentina. In this event were presented some papers on the following topics: radiotherapy in breast cancer; interaction between systemic treatments and radiotherapy; interstitial brachytherapy.

  17. Crichton ambiguities with infinitely many partial waves

    International Nuclear Information System (INIS)

    Atkinson, D.; Kok, L.P.; de Roo, M.

    1978-01-01

    We construct families of spinless two-particle unitary cross sections that possess a nontrivial discrete phase-shift ambiguity, with in general an infinite number of nonvanishing partial waves. A numerical investigation reveals that some of the previously known finite Crichton ambiguities are merely special cases of the newly constructed examples

  18. Group-wise partial least square regression

    NARCIS (Netherlands)

    Camacho, José; Saccenti, Edoardo

    2018-01-01

    This paper introduces the group-wise partial least squares (GPLS) regression. GPLS is a new sparse PLS technique where the sparsity structure is defined in terms of groups of correlated variables, similarly to what is done in the related group-wise principal component analysis. These groups are

  19. Partial axillary dissection in early breast cancer

    African Journals Online (AJOL)

    Tarek Abdel Halim El-Fayoumi

    ORIGINAL ARTICLE. Partial axillary dissection in early breast cancer. Tarek Abdel Halim El-Fayoumi *. Department of General Surgery, Faculty of Medicine, Alexandria University, Egypt. Received 16 October 2012; accepted 7 January 2013. Available online 7 March 2013. KEYWORDS. Breast cancer;. Axillary lymph nodes.

  20. [Designing metal frame removable partial dentures

    NARCIS (Netherlands)

    Witter, D.J.; Barel, J.C.; Keltjens, H.M.A.M.; Creugers, N.H.J.

    2011-01-01

    Oral health care providers have the full responsibility for designing metal frame removable partial dentures and making all of the necessary preparations. Important principles of design are that the denture should hamper natural cleaning and daily oral hygiene as little as possible and that it

  1. psychrometry: from partial pressures to mole fractions

    African Journals Online (AJOL)

    ES Obe

    1980-03-01

    Mar 1, 1980 ... as an ideal gas mixture. Partial pressures then become identical: to mole fractions and sets of psychometric parameters result from rather elementary thermodynamic relations. Search for more accurate data has long led to the realization that neither dry air nor pure water vapour behaves like an ideal gas,.

  2. Partial purification and characterization of metalloprotease of ...

    African Journals Online (AJOL)

    USER

    2013-07-31

    Jul 31, 2013 ... The supplementation of partially purified enzyme preparation in detergents such as Rin and Wheel significantly improved their cleansing efficiency as blood and fish curry stains on the cloth disappeared within 15 min (Figure 6). Our finding go hand in hand with earlier findings on Bacillus licheniformis ...

  3. Partial purification, characterization and hydrolytic activities of ...

    African Journals Online (AJOL)

    α-Amylase and amyloglucosidase produced by amylolytic Bacillus licheniformis and Aspergillus niger isolated from plantain and yam peels media were partially purified and characterized. Following cultivation of the microbial isolates on the agricultural residue media, crude enzyme solutions were obtained by filtration and ...

  4. Partial Evaluation of the Euclidian Algorithm

    DEFF Research Database (Denmark)

    Danvy, Olivier; Goldberg, Mayer

    1997-01-01

    Some programs are easily amenable to partial evaluation because their control flow clearly depends on one of their parameters. Specializing such programs with respect to this parameter eliminates the associated interpretive overhead. Some other programs, however, do not exhibit this interpreter-l...

  5. Crichton ambiguities with infinitely many partial waves

    NARCIS (Netherlands)

    Atkinson, D.; Kok, L.P.; de Roo, M.

    We construct families of spin less two-particle unitary cross sections that possess a nontrivial discrete phase-shift ambiguity, with in general an infinite number of nonvanishing partial waves. A numerical investigation reveals that some of the previously known finite Crichton ambiguities are

  6. Partial differential equations in several complex variables

    CERN Document Server

    Chen, So-Chin

    2001-01-01

    This book is intended both as an introductory text and as a reference book for those interested in studying several complex variables in the context of partial differential equations. In the last few decades, significant progress has been made in the fields of Cauchy-Riemann and tangential Cauchy-Riemann operators. This book gives an up-to-date account of the theories for these equations and their applications. The background material in several complex variables is developed in the first three chapters, leading to the Levi problem. The next three chapters are devoted to the solvability and regularity of the Cauchy-Riemann equations using Hilbert space techniques. The authors provide a systematic study of the Cauchy-Riemann equations and the \\bar\\partial-Neumann problem, including L^2 existence theorems on pseudoconvex domains, \\frac 12-subelliptic estimates for the \\bar\\partial-Neumann problems on strongly pseudoconvex domains, global regularity of \\bar\\partial on more general pseudoconvex domains, boundary ...

  7. A Partial Theory of Executive Succession.

    Science.gov (United States)

    Thiemann, Francis C.

    This study has two purposes: (1) To construct a partial theory of succession, and (2) to utilize a method of theory construction which combines some of the concepts of Hans Zetterberg with the principles of formal symbolic logic. A bibliography on succession in complex organizations with entries on descriptive and empirical studies from various…

  8. Microbial Flora of Partially Processed Periwinkles (Tympantotonus ...

    African Journals Online (AJOL)

    A survey of microbial flora of partially processed periwinkles (Tympanotonus fuscatus) sold in six markets in Port Harcourt was undertaken for twelve weeks. Results show that all samples of periwinkles were contaminated with Staphylococcus aureus, Bacillus sp., Escherichia coil, Staphepidermidis sp., Micrococcus sp., ...

  9. A note on partial vertical integration

    NARCIS (Netherlands)

    G.W.J. Hendrikse (George); H.J.M. Peters (Hans)

    1989-01-01

    textabstractA simple model is constructed to show how partial vertical integration may emerge as an equilibrium market structure in a world characterized by rationing, differences in the reservation prices of buyers, and in the risk attitudes of buyers and sellers. The buyers with the high

  10. Memorization in Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Balat, Vincent; Danvy, Olivier

    2002-01-01

    We use a code generator—type-directed partial evaluation— to verify conversions between isomorphic types, or more precisely to verify that a composite function is the identity function at some complicated type. A typed functional language such as ML provides a natural support to express the funct...

  11. Testing the generalized partial credit model

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    1996-01-01

    The partial credit model (PCM) (G.N. Masters, 1982) can be viewed as a generalization of the Rasch model for dichotomous items to the case of polytomous items. In many cases, the PCM is too restrictive to fit the data. Several generalizations of the PCM have been proposed. In this paper, a

  12. Some Considerations on the Partial Credit Model

    Science.gov (United States)

    Verhelst, N. D.; Verstralen, H. H. F. M.

    2008-01-01

    The Partial Credit Model (PCM) is sometimes interpreted as a model for stepwise solution of polytomously scored items, where the item parameters are interpreted as difficulties of the steps. It is argued that this interpretation is not justified. A model for stepwise solution is discussed. It is shown that the PCM is suited to model sums of binary…

  13. Pragmatics of type-directed partial evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1996-01-01

    Type-directed partial evaluation stems from the residualization of static values in dynamic contexts, given their type and the type of their free variables. Its algorithm coincides with the algorithm for coercing a subtype value into a supertype value, which itself coincides with Berger and Schwi...

  14. Complete destructive interference of partially coherent fields

    NARCIS (Netherlands)

    Gbur, G.J.; Visser, T.D.; Wolf, E.

    2004-01-01

    A three-point source model is used to study the interference of wavefields which are mutually partially coherent. It is shown that complete destructive interference of the fields is possible in such a "three-pinhole interferometer" even if the sources are not fully coherent with respect to each

  15. Partial Polarization in Interfered Plasmon Fields

    Directory of Open Access Journals (Sweden)

    P. Martínez Vara

    2014-01-01

    Full Text Available We describe the polarization features for plasmon fields generated by the interference between two elemental surface plasmon modes, obtaining a set of Stokes parameters which allows establishing a parallelism with the traditional polarization model. With the analysis presented, we find the corresponding coherence matrix for plasmon fields incorporating to the plasmon optics the study of partial polarization effects.

  16. Partial Automated Alignment and Integration System

    Science.gov (United States)

    Kelley, Gary Wayne (Inventor)

    2014-01-01

    The present invention is a Partial Automated Alignment and Integration System (PAAIS) used to automate the alignment and integration of space vehicle components. A PAAIS includes ground support apparatuses, a track assembly with a plurality of energy-emitting components and an energy-receiving component containing a plurality of energy-receiving surfaces. Communication components and processors allow communication and feedback through PAAIS.

  17. Design of multistable systems via partial synchronization

    Indian Academy of Sciences (India)

    Mohammad Ali Khan

    2017-07-05

    Jul 5, 2017 ... The basic idea of the scheme is to design partial synchronization of states between the coupled systems and ... Numerical simulation results consisting of ... systems of the same order via active control is discussed. In §3, the ...

  18. Partially Decentralized Control Architectures for Satellite Formations

    Science.gov (United States)

    Carpenter, J. Russell; Bauer, Frank H.

    2002-01-01

    In a partially decentralized control architecture, more than one but less than all nodes have supervisory capability. This paper describes an approach to choosing the number of supervisors in such au architecture, based on a reliability vs. cost trade. It also considers the implications of these results for the design of navigation systems for satellite formations that could be controlled with a partially decentralized architecture. Using an assumed cost model, analytic and simulation-based results indicate that it may be cheaper to achieve a given overall system reliability with a partially decentralized architecture containing only a few supervisors, than with either fully decentralized or purely centralized architectures. Nominally, the subset of supervisors may act as centralized estimation and control nodes for corresponding subsets of the remaining subordinate nodes, and act as decentralized estimation and control peers with respect to each other. However, in the context of partially decentralized satellite formation control, the absolute positions and velocities of each spacecraft are unique, so that correlations which make estimates using only local information suboptimal only occur through common biases and process noise. Covariance and monte-carlo analysis of a simplified system show that this lack of correlation may allow simplification of the local estimators while preserving the global optimality of the maneuvers commanded by the supervisors.

  19. A partial account of presupposition projection

    NARCIS (Netherlands)

    Beaver, D.; Krahmer, E.J.

    2001-01-01

    In this paper it is shown how a partial semantics for presuppositions can be given which is empirically more satisfactory than its predecessors, and how this semantics can be integrated with a technically sound, compositional grammar in the Montagovian fashion. Additionally, it is argued that the

  20. Pipeline transportation of emerging partially upgraded bitumen

    International Nuclear Information System (INIS)

    Luhning, R.W.; Anand, A.; Blackmore, T.; Lawson, D.S.

    2002-01-01

    The recoverable reserves of Canada's vast oil deposits is estimated to be 335 billion barrels (bbl), most of which are in the Alberta oil sands. Canada was the largest import supplier of crude oil to the United States in 2001, followed by Saudi Arabia. By 2011, the production of oil sands is expected to increase to 50 per cent of Canada's oil, and conventional oil production will decline as more production will be provided by synthetic light oil and bitumen. This paper lists the announced oil sands projects. If all are to proceed, production would reach 3,445,000 bbl per day by 2011. The three main challenges regarding the transportation and marketing of this new production were described. The first is to expand the physical capacity of existing pipelines. The second is the supply of low viscosity diluent (such as natural gas condensate or synthetic diluent) to reduce the viscosity and density of the bitumen as it passes through the pipelines. The current pipeline specifications and procedures to transport partially upgraded products are presented. The final challenge is the projected refinery market constraint to process the bitumen and synthetic light oil into consumer fuel products. These challenges can be addressed by modifying refineries and increasing Canadian access in Petroleum Administration Defense District (PADD) II and IV. The technology for partial upgrading of bitumen to produce pipeline specification oil, reduce diluent requirements and add sales value, is currently under development. The number of existing refineries to potentially accept partially upgraded product is listed. The partially upgraded bitumen will be in demand for additional upgrading to end user products, and new opportunities will be presented as additional pipeline capacity is made available to transport crude to U.S. markets and overseas. The paper describes the following emerging partial upgrading methods: the OrCrude upgrading process, rapid thermal processing, CPJ process for

  1. Treatment planning: implant-supported partial overdentures.

    Science.gov (United States)

    Chee, Winston W L

    2005-04-01

    When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the

  2. [Partial splenectomy in sickle cell disease].

    Science.gov (United States)

    Gutiérrez Díaz, A I; Svarch, E; Arencibia Núñez, A; Sabournin Ferrier, V; Machín García, S; Menendez Veitía, A; Ramón Rodriguez, L; Serrano Mirabal, J; García Peralta, T; López Martin, L G

    2015-04-01

    Total splenectomy in sickle cell disease is related to a high risk of fulminant sepsis and increased incidence of other events, which have not been reported in patients with partial splenectomy. In this study we examined the patients with sickle cell disease and partial splenectomy and compared the clinical and laboratory results with non-splenectomized patients. We studied 54 patients with sickle cell disease who underwent partial splenectomy in childhood from 1986 until 2011 at the Institute of Hematology and Immunology. They were compared with 54 non-splenectomized patients selected by random sampling with similar characteristics. Partial splenectomy was performed at a mean age of 4.1 years, with a higher frequency in homozygous hemoglobin S (70.4%), and the most common cause was recurrent splenic sequestration crisis. The most common postoperative complications were fever of unknown origin (14.8%) and acute chest syndrome (11.1%). After splenectomy there was a significant increase in leukocytes, neutrophils, and platelets, the latter two parameters remained significantly elevated when compared with non-splenectomized patients. There was no difference in the incidence of clinical events, except hepatic sequestration, which was more common in splenectomized patients. Partial splenectomy was a safe procedure in patients with sickle cell disease. There were no differences in the clinical picture in children splenectomized and non-splenectomized except the greater frequency of hepatic sequestration crisis in the first group. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  3. Monotherapy for partial epilepsy: focus on levetiracetam

    Directory of Open Access Journals (Sweden)

    Antonio Gambardella

    2008-03-01

    Full Text Available Antonio Gambardella1,2, Angelo Labate1,2, Eleonora Colosimo1, Roberta Ambrosio1, Aldo Quattrone1,21Institute of Neurology, University Magna Græcia, Catanzaro, Italy; 2Institute of Neurological Sciences, National Research Council, Piano Lago di Mangone, Cosenza, ItalyAbstract: Levetiracetam (LEV, the S-enantiomer of alpha-ethyl-2-oxo-1-pyrollidine acetamide, is a recently licensed antiepileptic drug (AED for adjunctive therapy of partial seizures. Its mechanism of action is uncertain but it exhibits a unique profile of anticonvulsant activity in models of chronic epilepsy. Five randomized, double-blind, placebo-controlled trials enrolling adult or pediatric patients with refractory partial epilepsy have demonstrated the efficacy of LEV as adjunctive therapy, with a responder rate (≥50% reduction in seizure frequency of 28%–45%. Long-term efficacy studies suggest retention rates of 60% after one year, with 13% of patients seizure-free for 6 months of the study and 8% seizure-free for 1 year. More recent studies illustrated successful conversion to monotherapy in patients with refractory epilepsy, and its effectiveness as a single agent in partial epilepsy. LEV has also efficacy in generalized epilepsies. Adverse effects of LEV, including somnolence, lethargy, and dizziness, are generally mild and their occurrence rate seems to be not significantly different from that observed in placebo groups. LEV also has no clinically significant pharmacokinetic interactions with other AEDs, or with commonly prescribed medications. The combination of effective antiepileptic properties with a relatively mild adverse effect profile makes LEV an attractive therapy for partial seizures.Keywords: levetiracetam, partial epilepsy, antiepileptic drugs

  4. ALFVEN WAVES IN A PARTIALLY IONIZED TWO-FLUID PLASMA

    Energy Technology Data Exchange (ETDEWEB)

    Soler, R.; Ballester, J. L.; Terradas, J. [Departament de Fisica, Universitat de les Illes Balears, E-07122 Palma de Mallorca (Spain); Carbonell, M., E-mail: roberto.soler@uib.es, E-mail: joseluis.ballester@uib.es, E-mail: jaume.terradas@uib.es, E-mail: marc.carbonell@uib.es [Departament de Matematiques i Informatica, Universitat de les Illes Balears, E-07122 Palma de Mallorca (Spain)

    2013-04-20

    Alfven waves are a particular class of magnetohydrodynamic waves relevant in many astrophysical and laboratory plasmas. In partially ionized plasmas the dynamics of Alfven waves is affected by the interaction between ionized and neutral species. Here we study Alfven waves in a partially ionized plasma from the theoretical point of view using the two-fluid description. We consider that the plasma is composed of an ion-electron fluid and a neutral fluid, which interact by means of particle collisions. To keep our investigation as general as possible, we take the neutral-ion collision frequency and the ionization degree as free parameters. First, we perform a normal mode analysis. We find the modification due to neutral-ion collisions of the wave frequencies and study the temporal and spatial attenuation of the waves. In addition, we discuss the presence of cutoff values of the wavelength that constrain the existence of oscillatory standing waves in weakly ionized plasmas. Later, we go beyond the normal mode approach and solve the initial-value problem in order to study the time-dependent evolution of the wave perturbations in the two fluids. An application to Alfven waves in the low solar atmospheric plasma is performed and the implication of partial ionization for the energy flux is discussed.

  5. Reconsidering harmonic and anharmonic coherent states: Partial differential equations approach

    Energy Technology Data Exchange (ETDEWEB)

    Toutounji, Mohamad, E-mail: Mtoutounji@uaeu.ac.ae

    2015-02-15

    This article presents a new approach to dealing with time dependent quantities such as autocorrelation function of harmonic and anharmonic systems using coherent states and partial differential equations. The approach that is normally used to evaluate dynamical quantities involves formidable operator algebra. That operator algebra becomes insurmountable when employing Morse oscillator coherent states. This problem becomes even more complicated in case of Morse oscillator as it tends to exhibit divergent dynamics. This approach employs linear partial differential equations, some of which may be solved exactly and analytically, thereby avoiding the cumbersome noncommutative algebra required to manipulate coherent states of Morse oscillator. Additionally, the arising integrals while using the herein presented method feature stability and high numerical efficiency. The correctness, applicability, and utility of the above approach are tested by reproducing the partition and optical autocorrelation function of the harmonic oscillator. A closed-form expression for the equilibrium canonical partition function of the Morse oscillator is derived using its coherent states and partial differential equations. Also, a nonequilibrium autocorrelation function expression for weak electron–phonon coupling in condensed systems is derived for displaced Morse oscillator in electronic state. Finally, the utility of the method is demonstrated through further simplifying the Morse oscillator partition function or autocorrelation function expressions reported by other researchers in unevaluated form of second-order derivative exponential. Comparison with exact dynamics shows identical results.

  6. Partial Granger causality--eliminating exogenous inputs and latent variables.

    Science.gov (United States)

    Guo, Shuixia; Seth, Anil K; Kendrick, Keith M; Zhou, Cong; Feng, Jianfeng

    2008-07-15

    Attempts to identify causal interactions in multivariable biological time series (e.g., gene data, protein data, physiological data) can be undermined by the confounding influence of environmental (exogenous) inputs. Compounding this problem, we are commonly only able to record a subset of all related variables in a system. These recorded variables are likely to be influenced by unrecorded (latent) variables. To address this problem, we introduce a novel variant of a widely used statistical measure of causality--Granger causality--that is inspired by the definition of partial correlation. Our 'partial Granger causality' measure is extensively tested with toy models, both linear and nonlinear, and is applied to experimental data: in vivo multielectrode array (MEA) local field potentials (LFPs) recorded from the inferotemporal cortex of sheep. Our results demonstrate that partial Granger causality can reveal the underlying interactions among elements in a network in the presence of exogenous inputs and latent variables in many cases where the existing conditional Granger causality fails.

  7. Resolution in partially accomodative esotropia during occlusion treatment for amblyopia.

    Science.gov (United States)

    Koc, F; Ozal, H; Yasar, H; Firat, E

    2006-03-01

    To evaluate alignment changes in partially accommodative esotropia during occlusion treatment for amblyopia. Changes at the deviation angles of 63 partially accommodative esotropia patients, who had occlusion treatment for amblyopia, were evaluated retrospectively. Mean deviation angle at the start of therapy without glasses was 45 PD (10-90 PD) and became 27 PD (5-70 PD) after at least 2 months with glasses. During 12 (2-36) months of occlusion period, mean manifest deviation angle with glasses decreased to 11 PD (0-50) (P amblyopia resolved in 71.5% of the cases. After termination of amblyopia treatment 24 (38%) cases had surgery for the residual deviation but if we had planned surgery before amblyopia treatment, 81% of the patients would have had surgery. Should amblyopia be treated initially or should we operate first in patients with strabismus and amblyopia together? Our research suggests that we should not hurry to operate in high hypermetropic partially accommodative cases, which have amblyopia and a long-term history of strabismus. Initial amblyopia treatment in these cases allows time for resolution of the nonaccomodative component in strabismus and can significantly decrease the necessity for surgery.

  8. Partial aphid resistance in lettuce negatively affects parasitoids.

    Science.gov (United States)

    Lanteigne, Marie-Eve; Brodeur, Jacques; Jenni, Sylvie; Boivin, Guy

    2014-10-01

    This study investigated the effects of partial plant resistance on the lettuce aphid Nasonovia ribisnigri (Mosley) (Hemiptera: Aphididae), a major pest of cultivated lettuce (Lactuca sativa L.), and one of its parasitoids, Aphidius ervi Haliday (Hymenoptera: Braconidae). Aphids were reared on susceptible (L. sativa variety Estival; S) or partially resistant (Lactuca serriola L. PI 491093; PR) lettuce, and next parasitized by A. ervi females. Fitness proxies were measured for both aphids and parasitoids. Developmental time to adult stage took longer for alate and apterous aphids (an average of 3.5 and 1.5 additional days, respectively) on PR than on S lettuce, and fecundity of alate aphids reared on PR lettuce was reduced by 37.8% relative to those reared on S lettuce. Size (tibia length) and weight of aphids reared on PR lettuce were lower than for aphids reared on S lettuce from the third and second instar onward, respectively. Parasitism of aphids reared on PR plants resulted in lower parasitoid offspring emergence (-49.9%), lower adult female (-30.3%) and male (-27.5%) weight, smaller adult female (-17.5%) and male (-11.9%) size, and lower female fecundity (37.8% fewer eggs) than when parasitoids developed from aphids reared on S plants. Our results demonstrate that partial aphid resistance in lettuce negatively affects both the second and third trophic levels. Host plant resistance in cultivated lettuce may therefore create an ecological sink for aphid parasitoids.

  9. Laparoscopic partial cystectomy for urachal and bladder cancer

    Directory of Open Access Journals (Sweden)

    Jose R. Colombo Jr.

    2008-01-01

    Full Text Available PURPOSE: To report our initial experiences with laparoscopic partial cystectomy for urachal and bladder malignancy. MATERIALS AND METHODS: Between March 2002 and October 2004, laparoscopic partial cystectomy was performed in 6 cases at 3 institutions; 3 cases were urachal adenocarcinomas and the remaining 3 cases were bladder transitional cell carcinomas. All patients were male, with a median age of 55 years (45-72 years. Gross hematuria was the presenting symptom in all patients, and diagnosis was established with trans-urethral resection bladder tumor in 2 patients and by means of cystoscopic biopsy in the remaining 4 patients. Laparoscopic partial cystectomy was performed using the transperitoneal approach under cystoscopic guidance. In each case, the surgical specimen was removed intact entrapped in an impermeable bag. One patient with para-ureteral diverticulum transitional cell carcinoma required concomitant ureteral reimplantation. RESULTS: All six procedures were completed laparoscopically without open conversion. The median operating time was 110 minutes (90-220 with a median estimated blood loss of 70 mL (50-100. Frozen section evaluations of bladder margins were routinely obtained and were negative for cancer in all cases. The median hospital stay was 2.5 days (2-4 and the duration of catheterization was 7 days. There were no intraoperative or postoperative complications. Final histopathology confirmed urachal adenocarcinoma in 3 cases and bladder transitional cell carcinoma in 3 cases. At a median follow-up of 28.5 months (range: 26 to 44 months, there was no evidence of recurrent disease as evidenced by radiologic or cystoscopic evaluation. CONCLUSIONS: Laparoscopic partial cystectomy in carefully selected patients with urachal and bladder cancer is feasible and safe, offering a promising and minimally invasive alternative for these patients.

  10. Detecting and correcting partial errors: Evidence for efficient control without conscious access.

    Science.gov (United States)

    Rochet, N; Spieser, L; Casini, L; Hasbroucq, T; Burle, B

    2014-09-01

    Appropriate reactions to erroneous actions are essential to keeping behavior adaptive. Erring, however, is not an all-or-none process: electromyographic (EMG) recordings of the responding muscles have revealed that covert incorrect response activations (termed "partial errors") occur on a proportion of overtly correct trials. The occurrence of such "partial errors" shows that incorrect response activations could be corrected online, before turning into overt errors. In the present study, we showed that, unlike overt errors, such "partial errors" are poorly consciously detected by participants, who could report only one third of their partial errors. Two parameters of the partial errors were found to predict detection: the surface of the incorrect EMG burst (larger for detected) and the correction time (between the incorrect and correct EMG onsets; longer for detected). These two parameters provided independent information. The correct(ive) responses associated with detected partial errors were larger than the "pure-correct" ones, and this increase was likely a consequence, rather than a cause, of the detection. The respective impacts of the two parameters predicting detection (incorrect surface and correction time), along with the underlying physiological processes subtending partial-error detection, are discussed.

  11. Playing Games with Timed Games

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Chatain, Thomas

    2009-01-01

    In this paper we focus on property-preserving preorders between timed game automata and their application to control of partially observable systems. Following the example of timed simulation between timed automata, we define timed alternating simulation as a preorder between timed game automata......, which preserves controllability. We define a method to reduce the timed alternating simulation problem to a safety game. We show how timed alternating simulation can be used to control efficiently a partially observable system. This method is illustrated by a generic case study....

  12. The Effect of Influent Characteristics and Operational Conditions over the Performance and Microbial Community Structure of Partial Nitritation Reactors

    Directory of Open Access Journals (Sweden)

    Alejandro Rodriguez-Sanchez

    2014-06-01

    Full Text Available Nitrogen is a main contaminant of wastewater worldwide. Novel processes for nitrogen removal have been developed over the last several decades. One of these is the partial nitritation process. This process includes the oxidation of ammonium to nitrite without the generation of nitrate. The partial nitritation process has several advantages over traditional nitrification-denitrification processes for nitrogen removal from wastewaters. In addition, partial nitritation is required for anammox elimination of nitrogen from wastewater. Partial nitritation is affected by operational conditions and substances present in the influent, such as quinolone antibiotics. In this review, the impact that several operational conditions, such as temperature, pH, dissolved oxygen concentration, hydraulic retention time and solids retention time, have over the partial nitritation process is covered. The effect of quinolone antibiotics and other emerging contaminants are discussed. Finally, future perspectives for the partial nitritation process are commented upon.

  13. PARTIAL TRISOMY 4p AND PARTIAL MONOSOMY 13q: CASE REPORT AND A LITERATURE REVIEW.

    Science.gov (United States)

    Puvabanditsin, S; Herrera-Garcia, G; Gengel, N; Hussein, K; February, M; Mayne, J; Mehta, R

    2016-01-01

    We report on a term first born dichorionic-diamniotic twin with deletion of the distal long arm of chromosome 13, partial trisomy of the short arm of chromosome 4, intrauterine growth retardation, and multiple anomalies including microcephaly, colpocephaly, absent corpus callosum, bulbous tip of the nose, large and low set ears, macroglossia, thin upper lip, double outlet right ventricle, atria/ventricular septal defect, cleft mitral valve, pulmonary stenosis, single umbilical artery, multicystic dysplastic left kidney, sacral dimple, anterior displacement of anus, simian creases, abnormal thumb (congenital clasped thumb), overlapping toes, and congenital hypothyroidism. This is the first report of a patient with partial trisomy 4p and partial monosomy 13q.

  14. 40 CFR Table 7 to Subpart Vvvvvv... - Partially Soluble HAP

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Partially Soluble HAP 7 Table 7 to... Pt. 63, Subpt. VVVVVV, Table 7 Table 7 to Subpart VVVVVV of Part 63—Partially Soluble HAP As required... partially soluble HAP listed in the following table. Partially soluble HAP name CAS No. 1. 1,1,1...

  15. Partial rectangular metric spaces and fixed point theorems.

    Science.gov (United States)

    Shukla, Satish

    2014-01-01

    The purpose of this paper is to introduce the concept of partial rectangular metric spaces as a generalization of rectangular metric and partial metric spaces. Some properties of partial rectangular metric spaces and some fixed point results for quasitype contraction in partial rectangular metric spaces are proved. Some examples are given to illustrate the observed results.

  16. On obtaining Knuth, Morris, and Pratt's string matcher by partial evaluation

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Rohde, Henning Korsholm

    2002-01-01

    We present the first formal proof that partial evaluation of a quadratic string matcher can yield the precise behaviour of the KMP string matcher. Obtaining the KMP is a canonical example of partial evaluation: one starts from the naive, quadratic program checking whether a pattern occurs in a text......; one observes that backtracking can be performed at partial-evaluation time (a binding-time shift); and one obtains a specialized program that does not back up on the text, a la KMP. We are not aware, however, of any formal proof that partial evaluation of a staged string matcher precisely yields...... the KMP string matcher. To compare the performance of the KMP and the result of specializing a staged string matcher, we have compared the traces of the successive indices at which the text is addressed. We have found that staged string matchers keeping no negative information do not perform as well...

  17. On Obtaining Knuth, Morris, and Pratt's String Matcher by Partial Evaluation

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Rohde, Henning Korsholm

    2002-01-01

    We present the first formal proof that partial evaluation of a quadratic string matcher can yield the precise behaviour of the KMP string matcher. Obtaining the KMP is a canonical example of partial evaluation: one starts from the naive, quadratic program checking whether a pattern occurs in a text......; one observes that backtracking can be performed at partial-evaluation time (a binding-time shift); and one obtains a specialized program that does not back up on the text, a la KMP. We are not aware, however, of any formal proof that partial evaluation of a staged string matcher precisely yields...... the KMP string matcher. To compare the performance of the KMP and the result of specializing a staged string matcher, we have compared the traces of the successive indices at which the text is addressed. We have found that staged string matchers keeping no negative information do not perform as well...

  18. Partial ureterectomy for a huge primary leiomyoma of the ureter

    International Nuclear Information System (INIS)

    Nouralizadeh, A.; Tabib, A.; Taheri, M.; Torbati, P.M.

    2010-01-01

    A case of a huge primary leiomyoma of the ureter in which only partial ureterectomy was performed is presented. The benign nature of the mass was primarily confirmed with frozen section at the time of surgery and then with immunohistochemistry (IHC). To the best of our knowledge, this case is a unique form of leiomyoma of the ureter due to its large size. There have been only ten cases of primary leiomyoma of the ureter reported since 1955 and all of them were very small in size. Our case is considered to be the eleventh. (author)

  19. Propagation of Partial Discharge and Noise Pulses in Turbine Generators

    DEFF Research Database (Denmark)

    Henriksen, Mogens; Stone, G. C.; Kurtz, M.

    1986-01-01

    Changes with time in the partial discharge (PD) activity originating in a generator stator's insulation system provide information about the electrical integrity of the stator winding. It is desirable to measure PD during normal service to minimize costs. To do this successfully, the influence...... of electrical interference must be reduced. Tests are reported which characterize the nature of discharge and noise pulses when using capacitive couplers mounted on each of the phase leads and an RF current transformer mounted on the neutral lead for signal detection. Significant differences between PD...... and electrical noise have been observed....

  20. Overeruption of teeth opposing removable partial dentures: a preliminary study.

    Science.gov (United States)

    Matsuda, Ken-Ichi; Miyashita, Yuji; Ikebe, Kazunori; Enoki, Kaori; Kurushima, Yuko; Mihara, Yusuke; Maeda, Yoshinobu

    2014-01-01

    One of the purposes of prosthodontic treatment is to prevent overeruption of opposing teeth, but there is currently minimal literature describing the efficacy of removable partial dentures (RPDs) in performing this function. This study investigated overeruption following RPD treatment. The study participants were 33 patients treated with RPDs, and overeruption was evaluated by comparing the surface computeraided design data of dental casts made at two different time points-before and after RPD treatment. Overeruption was observed in 38.1% of teeth opposed by the RPD, which was much less than the proportion of teeth that overerupted when not opposed by the RPD.

  1. Malliavin Calculus With Applications to Stochastic Partial Differential Equations

    CERN Document Server

    Sanz-Solé, Marta

    2005-01-01

    Developed in the 1970s to study the existence and smoothness of density for the probability laws of random vectors, Malliavin calculus--a stochastic calculus of variation on the Wiener space--has proven fruitful in many problems in probability theory, particularly in probabilistic numerical methods in financial mathematics.This book presents applications of Malliavin calculus to the analysis of probability laws of solutions to stochastic partial differential equations driven by Gaussian noises that are white in time and coloured in space. The first five chapters introduce the calculus itself

  2. Magnetic behavior of partially exchange-coupled particles

    International Nuclear Information System (INIS)

    Oliva, M.I.; Bercoff, P.G.; Bertorello, H.R.

    2005-01-01

    A system of particle pairs with partial exchange coupling is studied, considering identical particles and a fixed angle between their anisotropy axes. The energy of each pair is calculated in terms of the extent of interaction, β, as a function of the applied demagnetizing field. Using the probability per unit time for the inversion of magnetization, the coercive field H c and the viscosity S of the system are calculated. An unexpected result is that fully coupled particles are more stable against temperature than the uncoupled particles

  3. Data-driven discovery of partial differential equations.

    Science.gov (United States)

    Rudy, Samuel H; Brunton, Steven L; Proctor, Joshua L; Kutz, J Nathan

    2017-04-01

    We propose a sparse regression method capable of discovering the governing partial differential equation(s) of a given system by time series measurements in the spatial domain. The regression framework relies on sparsity-promoting techniques to select the nonlinear and partial derivative terms of the governing equations that most accurately represent the data, bypassing a combinatorially large search through all possible candidate models. The method balances model complexity and regression accuracy by selecting a parsimonious model via Pareto analysis. Time series measurements can be made in an Eulerian framework, where the sensors are fixed spatially, or in a Lagrangian framework, where the sensors move with the dynamics. The method is computationally efficient, robust, and demonstrated to work on a variety of canonical problems spanning a number of scientific domains including Navier-Stokes, the quantum harmonic oscillator, and the diffusion equation. Moreover, the method is capable of disambiguating between potentially nonunique dynamical terms by using multiple time series taken with different initial data. Thus, for a traveling wave, the method can distinguish between a linear wave equation and the Korteweg-de Vries equation, for instance. The method provides a promising new technique for discovering governing equations and physical laws in parameterized spatiotemporal systems, where first-principles derivations are intractable.

  4. Human Health Countermeasures - Partial-Gravity Analogs Workshop

    Science.gov (United States)

    Barr, Yael; Clement, Gilles; Norsk, Peter

    2016-01-01

    The experimental conditions that were deemed the most interesting by the HHC Element lead scientists are those permitting studies of the long-term effects of exposure to (a) chronic rotation when supine or in head down tilt (ground-based); and (b) long-radius centrifugation (space based). It is interesting to note that chronic ground based slow rotation room studies have not been performed since the 1960's, when the USA and USSR were investigating the potential use of AG for long-duration space missions. On the other hand, the other partial gravity analogs, i.e., parabolic flight, HUT, suspension, and short-radius centrifugation, have been regularly used in the last three decades (see review in Clément et al. 2015). Based on the workshop evaluations and the scores by the HHC scientific disciplines indicated in tables 3 and 4, simulation of partial G between 0 and 1 should be prioritized as follows: Priority 1. Chronic space-based partial-G analogs: a. Chronic space-based long-radius centrifugation. The ideal scenario would be chronic long-radius centrifugation of cells, animals and humans in a translational research approach - ideally beyond low earth orbit under deep space environmental effects and at various rotations - to obtain different G-effects. In this scenario, all physiological systems could be evaluated and the relationship between physiological response and G level established. This would be the most integrative way of defining, for the first time ever, G-thresholds for each physiological system. b. Chronic space-based centrifugation of animals. Chronic centrifugation of rodents at various G levels in space would allow for determination of AG thresholds of protection for each physiological system. In this case, all physiological systems will be of interest. Intermittent centrifugation will be of secondary interest. c. Chronic space-based centrifugation of cell cultures (RWV). Bioreactor studies of cells and cell cultures of various tissues at various G

  5. Partial peritoneal alimentation in an infant.

    Science.gov (United States)

    Merritt, R J; Atkinson, J B; Whalen, T V; Thomas, D W; Sinatra, F R; Roloson, G J

    1988-01-01

    We provided partial peritoneal alimentation to a 1.69-kg 11-month-old premature infant who had no available central venous access, depleted peripheral venous access, and gastrointestinal dysfunction. A cuffed silastic catheter was surgically inserted into the suprahepatic space. An alimentation solution was continuously infused into the peritoneum for 28 days to supplement peripheral venous and nasogastric alimentation and contributed 42 +/- 15% of total calories daily. Weight gain was achieved, but complications included hypoglycemia, hypophosphatemia, intravascular dehydration, catheter site leakage, ascites, and hydrocele. At autopsy 11 months later, lipid accumulation was present in the upper peritoneum and the hilar regions of the lungs secondary to preexisting lymphatic obstruction. Partial peritoneal alimentation may be feasible when other access routes are inadequate, but lymphatic obstruction is a contraindication to the peritoneal administration of lipid emulsions.

  6. An Imperative Type Hierarchy with Partial Products

    DEFF Research Database (Denmark)

    Schwartzbach, Michael Ignatieff; Schmidt, Erik Meineche

    1989-01-01

    notation for defining recursive types, that is superior to traditional type sums and products. We show how the ordering on types extends to an ordering on types with invariants. We allow the use of least upper bounds in type definitions and show how to compute upper bounds of invariants.......A type hierarchy for a programming language defines an ordering on the types such that any application for small types may be reused for all larger types. The imperative facet makes this non-trivial; the straight-forward definitions will yield an inconsistent system. We introduce a new type...... constructor, the partial product, and show how to define a consistent hierarchy in the context of fully recursive types. A simple polymorphism is derived by introducing a notion of placeholder types. By extending the partial product types to include structural invariants we obtain a particularly appropriate...

  7. Effective stress principle for partially saturated media

    International Nuclear Information System (INIS)

    McTigue, D.F.; Wilson, R.K.; Nunziato, J.W.

    1984-04-01

    In support of the Nevada Nuclear Waste Storage Investigation (NNWSI) Project, we have undertaken a fundamental study of water migration in partially saturated media. One aspect of that study, on which we report here, has been to use the continuum theory of mixtures to extend the classical notion of effective stress to partially saturated media. Our analysis recovers previously proposed phenomenological representations for the effective stress in terms of the capillary pressure. The theory is illustrated by specializing to the case of linear poroelasticity, for which we calculate the deformation due to the fluid pressure in a static capillary fringe. We then examine the transient consolidation associated with liquid flow induced by an applied surface load. Settlement accompanies this flow as the liquid is redistributed by a nonlinear diffusion process. For material properties characteristic of tuff from the Nevada Test Site, these effects are found to be vanishingly small. 14 references, 7 figures, 1 table

  8. Partial differential operators of elliptic type

    CERN Document Server

    Shimakura, Norio

    1992-01-01

    This book, which originally appeared in Japanese, was written for use in an undergraduate course or first year graduate course in partial differential equations and is likely to be of interest to researchers as well. This book presents a comprehensive study of the theory of elliptic partial differential operators. Beginning with the definitions of ellipticity for higher order operators, Shimakura discusses the Laplacian in Euclidean spaces, elementary solutions, smoothness of solutions, Vishik-Sobolev problems, the Schauder theory, and degenerate elliptic operators. The appendix covers such preliminaries as ordinary differential equations, Sobolev spaces, and maximum principles. Because elliptic operators arise in many areas, readers will appreciate this book for the way it brings together a variety of techniques that have arisen in different branches of mathematics.

  9. Crowdfunding Through a Partial Organization Lens

    DEFF Research Database (Denmark)

    Nielsen, Kristian Roed

    2018-01-01

    Crowdfunding has become a rapidly growing source of alternative financing for a wide range of products and service ideas. The crowdfunding process itself necessitates the successful interaction between a number of actors including the central organizing platform, a number of content providing...... campaigns, and a large diverse group of funders. By utilizing the literature on complete and partial organizations and rejecting the commonly applied organizational molds to describe the process, this paper proposes that crowdfunding is organized and enabled as a fluid and co-dependent interaction between...... the various actors. The concept of partial organizations and its emphasis on key organizational decisions reveal that crowdfunding may be conceived of as a “co-dependent organization” in which the relationship of the involved actors is so interdependent that the crowdfunding process can neither be maintained...

  10. Bactericidal activity of partially oxidized nanodiamonds.

    Science.gov (United States)

    Wehling, Julia; Dringen, Ralf; Zare, Richard N; Maas, Michael; Rezwan, Kurosch

    2014-06-24

    Nanodiamonds are a class of carbon-based nanoparticles that are rapidly gaining attention, particularly for biomedical applications, i.e., as drug carriers, for bioimaging, or as implant coatings. Nanodiamonds have generally been considered biocompatible with a broad variety of eukaryotic cells. We show that, depending on their surface composition, nanodiamonds kill Gram-positive and -negative bacteria rapidly and efficiently. We investigated six different types of nanodiamonds exhibiting diverse oxygen-containing surface groups that were created using standard pretreatment methods for forming nanodiamond dispersions. Our experiments suggest that the antibacterial activity of nanodiamond is linked to the presence of partially oxidized and negatively charged surfaces, specifically those containing acid anhydride groups. Furthermore, proteins were found to control the bactericidal properties of nanodiamonds by covering these surface groups, which explains the previously reported biocompatibility of nanodiamonds. Our findings describe the discovery of an exciting property of partially oxidized nanodiamonds as a potent antibacterial agent.

  11. Absolute partial photoionization cross sections of ethylene

    Science.gov (United States)

    Grimm, F. A.; Whitley, T. A.; Keller, P. R.; Taylor, J. W.

    1991-07-01

    Absolute partial photoionization cross sections for ionization out of the first four valence orbitals to the X 2B 3u, A 2B 3g, B 2A g and C 2B 2u states of the C 2H 4+ ion are presented as a function of photon energy over the energy range from 12 to 26 eV. The experimental results have been compared to previously published relative partial cross sections for the first two bands at 18, 21 and 24 eV. Comparison of the experimental data with continuum multiple scattering Xα calculations provides evidence for extensive autoionization to the X 2B 3u state and confirms the predicted shape resonances in ionization to the A 2B 3g and B 2A g states. Identification of possible transitions for the autoionizing resonances have been made using multiple scattering transition state calculations on Rydberg excited states.

  12. Partial Androgen Insensitivity Syndrome Presenting with Gynecomastia

    Directory of Open Access Journals (Sweden)

    Sung Won Lee

    2015-06-01

    Full Text Available Gynecomastia is a benign enlargement of the male breast caused by the proliferation of glandular breast tissue. Determining the various causes of gynecomastia such as physiological causes, drugs, systemic diseases, and endocrine disorders is important. Androgen insensitivity syndrome (AIS is a rare endocrine disorder presenting with gynecomastia and is a disorder of male sexual differentiation caused by mutations within the androgen receptor gene. All individuals with AIS have the 46 XY karyotype, although AIS phenotypes can be classified as mild, partial or complete and can differ among both males and females including ambiguous genitalia or infertility in males. We experienced a case of partial AIS presenting with gynecomastia and identified the androgen receptor gene mutation.

  13. Neuromuscular Exercise Post Partial Medial Meniscectomy

    DEFF Research Database (Denmark)

    Hall, Michelle; Hinman, Rana S; Wrigley, Tim V

    2015-01-01

    PURPOSE: To evaluate the effects of a 12-week, home-based, physiotherapist-guided neuromuscular exercise program on the knee adduction moment (an indicator of mediolateral knee load distribution) in people with a medial arthroscopic partial meniscectomy within the past 3-12 months. METHODS......: An assessor-blinded, randomised controlled trial including people aged 30-50 years with no to mild pain following medial arthroscopic partial meniscectomy was conducted. Participants were randomly allocated to either a 12-week neuromuscular exercise program that targeted neutral lower limb alignment...... or a control group with no exercise. The exercise program included eight individual sessions with one of seven physiotherapists in private clinics, together with home exercises. Primary outcomes were the peak external knee adduction moment during normal pace walking and during a one-leg sit-to-stand. Secondary...

  14. Partial cross sections in H- photodetachment

    International Nuclear Information System (INIS)

    Halka, M.

    1993-04-01

    This dissertation reports experimental measurements of partial decay cross sections in the H - photodetachment spectrum. Observed decays of the 1 P 0 H -** (n) doubly-excitedresonances to the H(N=2) continuum are reported for n=2,3, and 4 from 1990 runs in which the author participated. A recent analysis of 1989 data revealing effects of static electric fields on the partial decay spectrum above 13.5 eV is also presented. The experiments were performed at the High Resolution Atomic Beam Facility. the Los Alamos Meson Physics Facility, with a relativistic H - beam (β=0.842)intersecting a ND:YAG laser. Variation of the intersection angle amounts to Doppler-shifting the photon energy, allowing continuous tuning of the laser energy as viewed from the moving ions' frame

  15. Computing the partial volume of pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wiencke, Bent [Nestle USA, Corporate Engineering, 800 N. Brand Blvd, Glendale, CA 91203 (United States)

    2010-06-15

    The computation of the partial and total volume of pressure vessels with various type of head profiles requires detailed knowledge of the head profile geometry. Depending on the type of head profile the derivation of the equations can become very complex and the calculation process cumbersome. Certain head profiles require numerical methods to obtain the partial volume, which for most application is beyond the scope of practicability. This paper suggests a unique method that simplifies the calculation procedure for the various types of head profiles by using one common set of equations without the need for numerical or complex computation methods. For ease of use, all equations presented in this paper are summarized in a single table format for horizontal and vertical vessels. (author)

  16. Deterministic dense coding with partially entangled states

    Science.gov (United States)

    Mozes, Shay; Oppenheim, Jonathan; Reznik, Benni

    2005-01-01

    The utilization of a d -level partially entangled state, shared by two parties wishing to communicate classical information without errors over a noiseless quantum channel, is discussed. We analytically construct deterministic dense coding schemes for certain classes of nonmaximally entangled states, and numerically obtain schemes in the general case. We study the dependency of the maximal alphabet size of such schemes on the partially entangled state shared by the two parties. Surprisingly, for d>2 it is possible to have deterministic dense coding with less than one ebit. In this case the number of alphabet letters that can be communicated by a single particle is between d and 2d . In general, we numerically find that the maximal alphabet size is any integer in the range [d,d2] with the possible exception of d2-1 . We also find that states with less entanglement can have a greater deterministic communication capacity than other more entangled states.

  17. Oxygen partial pressure sensor for gases

    International Nuclear Information System (INIS)

    Barbero, J.A.; Azcona, M.A.; Orce, A.

    1997-01-01

    Precise measurement of very low oxygen partial pressure is important in both laboratories and industries. Particularly in nuclear industry, it is relevant in the different steps of the nuclear fuel fabrication. It is presented an instrument which is handy and of easy construction, suitable for the measurement of oxygen partial pressure of gases, in the range of 10 -6 -1 atm. It is based on a solid electrolyte galvanic cell, using Yttria doped zirconia as a ceramic membrane. Through an indirect measurement and calibration, the instrument can be used to measure the content of free oxygen in liquids. It is a import feature in NPP instrumentation. The equipment was calibrated with mixtures of special nonreactive gases. (author). 5 refs

  18. Oxygen partial pressure sensor for gases

    Energy Technology Data Exchange (ETDEWEB)

    Barbero, J.A.; Azcona, M.A.; Orce, A. [Comision Nacional de Energia Atomica, San Carlos de Bariloche (Argentina). Centro Atomico Bariloche

    1997-10-01

    Precise measurement of very low oxygen partial pressure is important in both laboratories and industries. Particularly in nuclear industry, it is relevant in the different steps of the nuclear fuel fabrication. It is presented an instrument which is handy and of easy construction, suitable for the measurement of oxygen partial pressure of gases, in the range of 10{sup -6}-1 atm. It is based on a solid electrolyte galvanic cell, using Yttria doped zirconia as a ceramic membrane. Through an indirect measurement and calibration, the instrument can be used to measure the content of free oxygen in liquids. It is a import feature in NPP instrumentation. The equipment was calibrated with mixtures of special nonreactive gases. (author). 5 refs.

  19. Hamiltonian partial differential equations and applications

    CERN Document Server

    Nicholls, David; Sulem, Catherine

    2015-01-01

    This book is a unique selection of work by world-class experts exploring the latest developments in Hamiltonian partial differential equations and their applications. Topics covered within are representative of the field’s wide scope, including KAM and normal form theories, perturbation and variational methods, integrable systems, stability of nonlinear solutions as well as applications to cosmology, fluid mechanics and water waves. The volume contains both surveys and original research papers and gives a concise overview of the above topics, with results ranging from mathematical modeling to rigorous analysis and numerical simulation. It will be of particular interest to graduate students as well as researchers in mathematics and physics, who wish to learn more about the powerful and elegant analytical techniques for Hamiltonian partial differential equations.

  20. Esthetic double-structure fixed partial dentures.

    Science.gov (United States)

    Ravasini, G; Ugolini, G; Ravasini, F

    1996-04-01

    A new technical procedure for fixed partial dentures and single inlays allows the use of a metal supporting structure with independent ceramic coverage. The advantages of the technique are the bonding of metal to beveled dentinal margins with conventional cement and the acid-etched resin composite cementation of the ceramic, which permits more conservative preparation of the teeth. The complexity of the structure, the laboratory costs, and the doubling of the cementation procedures are the main disadvantages of the technique.